Mitsubishi Electric Cooling and Heating Solutions
Mitsubishi Electric HVAC products available in the US for thirty years have provided exceptional personalized comfort control while being very energy efficient
Mitsubishi Electrics INVERTER-driven compressor systems use refrigerant lines to connect an outdoor unit to one or more indoor air handlers A homes or buildings energy efficiency increases when only the amount of cooling or heating needed for the space where the unit is installed Advanced technologies are used to control the precise temperature in each room and have the capability to condition only the rooms in use
Using a wireless remote or wall-mounted controller for each space Mitsubishi Electric systems allow a truly personal level of comfort Environmentally friendly refrigerant (R410A) advanced filtration systems and high efficiency ratings are standard on all Mitsubishi Electric HVAC systems
This synergy of smart design and cutting-edge environmental technology delivers an end result of true eco-comfort for any conditioned space
----~
How environmentally friendly are Mitsubishi Electric HVAC systems
Mitsubishi Electric is dedicated to providing
environmentally responsible systems that minimize t the environment and our customers ENERGY STAR
PARTNERcarbon footprint
Mitsubishi Elelectrics environmental commitment is
evidenced by the fact that up to 83 of our system
components are recyclable More of our systems are
ENERGY STARreg certified and qualify for the federal tax
credit of up to $300 Local and state government and utility companies may provide tax credits and rebate
opportunities for energy-efficient systems See whats
available in your area by visiting wwwdsireusaorg
How many ENERGY STAR rated systems qualify for the federal tax credit 1 8 systems are ENERGY STAR rated
12 systems qualify for the federal tax credit
Qualified systems include the following products coolingshy
only heat pump H2ireg Hyper-Heating INVERTER heat-pump 2-to-1 and 3-to-1 multi-zone heat pump systems
For details on tax credit requirements visit
wwwmitsubishicomfortcomtaxcredit and for information on available local rebate opportunities from state or utility
companies visit wwwdsireusaorg which is a US Department of Energy information service
bull
Table of Contents
System Overview and Technology 04
System Lineup 08
MSIMSY Air Conditioner Specifications 10
MSZ Heat Pump Specifications 12
SEZ Heat Pump Specifications and Curves 14
SLZ Heat Pump Specifications 16
System Overview and Applications 18
MXZ-B Outdoor Unit Specifications 21
MXZ-8B48 Outdoor Unit Specifications 23
MSZIMFZISEZISLZ Indoor Unit Specifications 24
Rating Conditions Refrigerant Tubing 26
Line Lengths 26
Accessories 26
MXZ Port Adaptors 28
DIAMONDBACKreg Ball Valves 29
DIAMONDBACKregPlatform Stands 29
DIAMONDBACKreg Linesets 30
Filter Boxes 30
LlNE-HIDETM 31
Mitsubishi Electric System Technologies user-friendly zoned residential personalized comfort solutions
Mitsubishi Electric indoor units are easy to install-practically anywhere bull High on the wall to blend into a room without taking up window space bull In the ceiling or below the floor out of sight bull Low on the wall to be unobtrusive
Our systems are the perfect way to cool or heat any single room or multiple rooms in homes or office
Heat-pump systems feature auto mode which automatically switches between cooling and heating in response to changing needs Our systems are nearly silent their fans deliver air quietly and continuously with only a gentle whoosh for constant circulation and filtration For this reason Mitsubishi Electric split-zoning systems have long been the choice for thousands of homes churches schools and libraries across the US and the world
Technology Benefits of Mitsubishi Systems
Features Benefits INVERTER-DRIVEN Maximizes energy savings by making sure only the energy needed COMPRESSORS to cool or heat an area perfectly is used
Installs quickly and easily having no need for major constructionEASY INSTALLATION and remodeling
COMPLETE ZONE Realizes maximum control and energy efficiency by cooling CONTROL and heating only those spaces in use
ADVANCED Creates a comfortable environment no matter what conditions areMICROPROCESSOR outside with our advanced self-monitoring controlsTECHNOLOGY
PERSONAL COMFORT Offers comfort control of temperature fan speed and air direction CONTROL in the specific zone with dedicated controller
WASHABLE LONG-LIFE Improves air quality and saves money by washing ANTI-ALLERGEN FILTERS rather than replacing the filter
AUTO COOUHEAT Switches automatically from cooling to heatingCHANGEOVER (MUZISUZ systems) if desired
ENVIRONMENTALLY Uses R41 OA an environmentally friendly refrigerantFRIENDLY REFRIGERANT
Energy Effic iency Recognized Mitsubishi Electric split-zoning cooling-only and heat pump systems are so energy efficient that currently 18 systems of our INVERTER-driven systems are ENERGY STAR rated This can mean big savings
Add in the federal tax credit and local government and utility rebates and you have an ENERGY STAR opportunity to enjoy comfort at substantial savings PARTNER
For details on qualifying systems go to wwwmitsubishicomfortcomtaxcredit or use your smart phone to scan the tag to the left and go to the page
Visit wwwdsireusaorg for information on available local rebate opportunities from state or utility companies
Get the free app for your smart phone at httpgettagmobi
4 ~MITSUBISHI ELECTRIC
----
MITSUBISHI ELECTRIC 5
Innovative Variable-speed Compressor Technology Sophisticated electronic control systems detect any changes in room or zone temperashyture and-like a cars cruise control-automatically adjust the speed of the outdoor units INVERTER-driven compressor and electronic linear expansion valve (LEV) position for Rprecise capacity control The INVERTER-driven compressor is unlike those found in other systems which only start and stop repetitively Special components within the INVERTER compressor such as high density windings in the motor that increase the magnetic flux and artificial magnets in the rotor to reduce its weight allowi it to operate at higher energy efficiencies with better performance than ever before while producing low sound levels both during start-up and operation
MUZ-FE H2i Heating Capacity at Low Temperatures
120 - -~ I
gc100 --~--~~~~~~--~~~~~~
~ 80~~~~~~-+---~--~~~~--+-~shy()
OJ 60 ------+---j----t---t----t----t---J ~ _ MUZ-FE12NA
Q) 40 _ MUZ-FE18NA I __ UNITARY
~ 20 ---r--+---r--+--~--r-~~~--~~shy
o -13 -4 0 5 10 17 25 30 35 40 47
Outdoor Temperature Degrees FWB
Includes correction for defrost
-
~ l
~ Q) a E ~ 0 ~
o
Heat and Lots of It In addition to the already innovative INVERTER-driven compressor the MSZ -FE high-efficiency systems are also ENERGY STARreg rated and tax credit qualified up to 26 SEER delivering exceptional heating performance
These systems provide heating down to -130 F outdoor ambient and produce up to 100 heating capacity at 50 F MSZ-FE0918 92 capacity at 50 F for MSZ-FE12 Our systems provide year-round comfort in extreme climates while being extremely energy efficient There usually is no need for resistance electric or other supplemental energy-consuming devices with this performance
1seesensor i-seetrade Sensor (MSZ-FE0912NA models only)
The i-see Sensor detects temperature variations in hardshyto-control ceiling and floor areas and controls the airflow up to a wide lateral angle for ultimate comfort (900 angle in cooling mode) By scanning the room and adjusting airflow based on ambient temperature readings MSZ -FE systems achieve superior coolingheating performance with extremely efficient operation
INVERTER model Reaches set point quickly and uniform temperatures are maintained by finely-tuned control of compressor speed
Conventional model Takes longer to reach set point while the temperature is adjusted by switching the compressor off and on consuming additional energy
~ f------------ --_Time ---
Vl l
09shy(I)
I
N 0 l (I)
Vl ltV) (I)
3 0 lt(I)
s (I)
~ OJ l 0 --I (I) n r l 0 0
~
Superior Operation
Advanced Control Technology Through Mitsubishi Electrics advanced controls technology the indoor unit is powered by the outdoor unit Three polarity sensitive wires plus a ground conductor run from the outdoor to the indoor unit providing both power and data communication An advanced wireless remote control is standard on all ductless models An optional wired on-the-wall controller is available for wallshymountedfloor-standing indoor units on INVERTER systems (also requires MAC-397 If adapter) while standard on SEZ -KD ducted units
Quiet Operation Do you hear that No Mitsubishi Electric systems operate at low sound levels our indoor units produce decibels barely at a whisper level Compare to other common sounds
Police siren 118 decibels Circular saw 107 decibels Vacuum cleaner 74 decibels Whisper-tone voice 35 decibels Library reading room 33 decibels Our Indoor Units 19 - 34 decibels (at low speed)
Did you hear that We hope you did
Warm Air No Drafts Our hot-start heat-pump technology provides warmth from the beginning The fan increases in speed as the coil is warmed reducing drafts so when you want warm air you get it
TEMP
88
System Control Mitsubishi Electric offers a comprehensive remote controller that can adjust temperature fan speed and more Choose from four modes COOL HEAT AUTO and DRY The controller also has a 12-hour ONOFF timer for one-button control of your personal comfort
Easy to Maintain With easily accessible filters little or no ductwork to clean and simple wiring between the indoor and outdoor units Mitsubishi Electric systems require minimal maintenance providing another level of convenience
Auto Changeover on Heat-Pump Systems (MUZISUZ outdoor units)
Our heat-pump systems sense whether a space needs cooling or heating and automatically switch modes as needed to maintain a consistent temperature You can set it and forget it
6 MITSUBISHI ELECTRIC
----
Hybrid Catechin pre-filters -- shy
- shy
Total Comfort
Additional Air Circulation With the WIDE VANE or SWING mode available on the MSY(Z)-GE24 D3036NA there is an option for ~~~~lQcnborizontal airflow directions that provide 150
0
of lateral airflow for greater conditioned air circulation
-- -----_ ~~ iii
~~---- 150
0
Multiple Filters for Cleaner Healthier Ai r Mitsubishi Electric indoor units use a sophisticated multi-part filter system to remove contaminants such as allergens viruses and bacteria from the air
A hybrid catechin pre-filter absorbs odorshycausing gases The hybrid-coating process makes the catechin filter washable and - if properly maintained with regular cleaningshyremains effective for up to 10 years
A Blue-enzyme anti-allergen filter reduces germs bacteria and viruses and helps trap dust pollens mites and other particles The filter uses an enzyme catalyst to help break down the sulfur atom bonds in allergen proteins transforming them into non-allergen proteins and effectively cleaning the air The filter should be cleaned regularly to maintain efficiency
STANDARD FILTER SYSTEM (USED IN MSYMSZmiddotGElFE18GND MODELS)
Front Panel - shy
Blue Enzyme anti-allergen filter
ENHANCED FILTER SYSTEM (USED IN MSZmiddotFE0912NA MODELS)
Programmable Comfort Smart Set featured on MSZ-GE systems provides the option to program multiple settings into one quick-press feature providing an additional level of comfort control
The POWERFUL mode (found on select systems) is available to cool or heat any desired space quickly by lowering the set temperature in cooling mode or raising the set temperature in heating mode both by T F In POWERFUL Mode the fan speed increases for 15 minshyutes then the system resumes all standard operations
Vl l
OQ
([) I
N o l ([)
Vl lt(n r-+ ([)
3 o lt ([)
s ([)
~ OJ l a --I ([) nr l o o ~
The high-efficiency MSZ-FE0912NA indoor units incorporate the standard Catechin filter plus two more filters for triple filtration The second filter a Blueshyenzyme filter made of a fibrous material renders allergens harmless by using enzymes The third filter a Platinum Catalyst Deodorizing filter has a ceramic surface absorption element and uses nanotechnology for high-power odor absorption Periodic cleaning following the recommended procedures will maintain filter effectiveness for up to two years This combination of filters provides a complete air-purifying system within the ultimate comfort solution
Front Panel - shy
Hybrid Catechin pre-filters
cJ shy Blue Enzyme anti-allergen filter
I
MITSUBISHI ELECTRIC 7
---- -- -- -
System Lineup RESIDENTIAL AND LIGHT COMMERCIAL SYSTEM MODELS AND CONTROLLERS
SINGLE
MSMU Air Conditioners
9500 to 12000 Btuh 13 SEER
bull Provides cooling-only system bull Non-INVERTER rotary compressor bull Ideal for spaces such as
bedrooms garages out-buildings video monitoring
- ROOM WALL-MOUNTED Ale (cooling only)
MSYMUY Air Conditioners
3800 to 34600 Btuh Capacity Range 151 - 21 SEER
~ -
bull Cooling-only system bull INVERTER-driven compressor bull WIDE VANE for a wider angle of airflow 150
0
from left to right (on GE24D30D36 models)
bull Ideal for spaces such as bedrooms garages large open rooms and bonus rooms
SINGLE-ROOM WALL-MOUNTED HEAT PUMPS (coo lin g and heatin g)
MSZMUZ Heat Pumps
3800 to 33200 Btuh Capacity Range
145 - 21 SEER 82 - 10 HSPF
bull Uses INVERTER-driven compressor bull Provides cooling and heating in a wide range
of capacities bull Offers a WIDE VANE for a wider angle of airflow 1500 from
left to right (on GE24D30D36 models) bull Ideal for applications in bedrooms home offices living
rooms dining rooms bonus rooms basements kitchens guard houses and more
Up to 26 SEER
MSZMUZ-FE0912NA High - Efficiency Heat Pumps
2800 to 25200 BtuH capacity range 202 - 26 SEER
10 - 106 HSPF
bull INVERTER-driven compressor bull Quiet operation as low as 19dB(A) bull i-seetrade Sensor technology bull Enhanced filtration system bull H2ireg high~heat capabilities (see page 12 amp13)
MSZ-FE09 is 100 percent at 50 F MSZ -FE12 is 92 percent at 50 F MSZ-FE18 is 100 percent at 50 F
SI NGLE-ROOM LOW WALL or FLOOR-STANDING UNIT (fo r use with MXZ -8)
New to our lineup is a Low Wall or Floor-Standing model that can fit into those once difficult installations
MFZ These units provide comfort in spaces such as (For use with MXZ-8 finished attics with knee walls basements with Outdoor Units only) low ceilings and glass-walled sunrooms
bull Provides cooling and heating in Mounted three inches above floor level these models a wide range of capacities provide conditioned air two vents and provide direct
bull Two outlet air vents front-panel access to the filter for easy cleaning The - Upper vent for cooling or heating MFZ can even be recessed in a wall during installation - Bottom vent for heating only provided proper clearances are maintained (Currently there is
bull Flush or recessed installation no 1 1 system with M FZ)
8 MITSUBISHI ELECTRIC
SING LE -ROOM HORIZONTAL- DUCTED HEAT PUMPS (coo lin g and heat ing)
WIR ELESS and W IR ED REMOTE C O NTRO LLERS
PAR-21 MAA Wireless remote controller Set Temperature
for wall-mounted and floor-standing indoor units ----- OnOff
Timer Menu Fan Speed
Fan Speed Filter
Test Run Set Time
CheckEcono Cool
Airflow UpDown Timer OnOff
Louver
Ventilation
Reset ---- shy Optional wired controller for the SEZ SLZ and MFZ indoor units (Optional controller for wall-mounted is
available and floor-standing indoor units Unit requires MAC-397 If adapter)
MHK1 WIRELESS REMOTE CONTROLLER Exclusive for INVERTER-driven Mr Slimreg Systems
Wireless Technology a SEZ and SLZ 11 systems with SUZ outdoor unit only
MIFH1
MITSUBISHI ELECTRIC 9
AMITSUBISHI ELECTRIC
l~ 1000
~r t ~~~O
MRCH1
rtj n-shy --1r-a-1-shy
Mode ------ -- shy
SEZSUZ If your customer is looking for discrete zoned comfort then a short-run ducted unit Heat Pumps is the right solution As a stand-alone system or connected to a MXZ multi-room
3800 to 19000 BtuH system the SEZ ducted units provide energy efficiency quiet operation and a Capacity Range compact design for quick easy instqllation hidden either in the ceiling or beneath
15 SEER _---~~mm the floor 175 - 10 HSPF
J ~ All of the 11 systems are ENERGY STAR certified and two systems qualify for
~ the federal tax credit These systems provide customers with an environmentally friendly indoor unit with a similar installation and familiar style
These SEZ indoor units also connect to MXZ multi-zone systems providing a wide array of installation options to best fit any application
SING LE -R OO M C EI LING -REC ESSED CASSETTE UN IT
SLZSUZ Heat Pumps The SLZ -KA ceiling-recessed units casette offer a wide
3100 to 22200 BtuH air-flow pattern for better air distribution in a less obtrusive Capacity Range style These indoor units can be used in 11 heat pump
15 - 16 SEER and multi-zone systems providing more options to your customers Install SLZs in a hard ceiling (with a access panel for
bull 96 HSPF
servicing) or in a 2x2 extra space drop ceiling With a built-in drainshylift mechanism for condensate removal and a 4 ventilation-air intake knockout option and multiple options for the 11 systems the SLZ
~ ~ handles a variety of installation needs
Two of the three 11 systems are ENERGY STAR qualified
Vl l
OQ
(I) I
N o l (I)
Vl ltV (I)
3 Vl r o ~ n OJ V (I)
1shy(MS-A12WA MODEL SHOWN)
MS COOLING-ONLY
IJON-INVERTER
Model Name Indoor Unit
Outdoor Unit
MS-A09WA MS-A12WA
MU-A09WA MU-A12WA
Cooling 1
Rated Capacity Btuh 9500 12000
Capacity Range Btuh
Total Input W 870 1070
Energy Efficiency SEER 13
Moisture Removal Pintsh 27 32 Sensible Heat Factor 068 070
Power Supply Phase Cycle Voltage 1 Phase 60Hz 115V 2
Voltage Indoor - Outdoor L1-N AC 115V Indoor - Outdoor N-2 AC 115V Indoor - Remote Controller Wireless Type
Indoor Unit
MCA A 12
Fan Motor FLA 095
Airilow (Lo-Med-Hi Poweriul)
DRY (CFM) 183-261-335-367 222-286-406-446
WET (CFM) 162-233-300-328 198-254-363-399
Sound Pressure Level (Lo-Med-Hi)
dB(A) 26-32-40-42 33-38-45
External Finish Color Munsell No 1OY 9202
Dimension Unit
W In 30-1116
0 In 8-14
H In 11-34
Weight Unit Lbs 23
Field Drainpipe Size 00 In 58
Outdoor Unit
MCA A 14 16
MOCP (Time Delay) A 15 20
Fan Motor FLA 063 093
Compressor
Model (Type) Single Rotary
RLA 93 1082
LRA 47 56
Airilow CFM 1083 1327
Refrigerant Control Capillary Tube
Sound Pressure Level (Cooling) 1
dB(A) 47 52
External Finish Color Munsell No 3Y 7811
Dimensions
W In 31-12 33-716
0 In 11-14 11-716
H In 21-58 23-1316
Weight Lbs 78 96
Remote Controller Type Wireless Remote
Refrigerant
Type R410A Charge Lbs Oz 25 31
Oil Type (FI Oz) NE022 (108)
Refrigerant Pipe
Gas Side 00 In 38 12
Liquid Side 00 14
Height Difference (Max) Ft 35
Length (Max) 65
Connection Method IndoorOutdoor FlaredFlared
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling) - Indoor DB 800 F(270 e) WB 670 F(190 e) Outdoor DB 950 F(350 e) WB 750 F(240 e) 2 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice
LlIVIITED WARRANTY ISeven-year warranty on compressor Five-year warranty on parts
10 MITSUBISHI ELECTRIC
I
R ---I Vl
J(MSY-GE1 7NA MODEL SHOWN) OQ
MSY COOLI NG-ON LY (CO NT ) CD N o J CD
s Vl OJ J
Cooling 1 0shy
s Vl -lt Vl
~~~~~-=~------~~--------------------------~~~~----------------------------~ jVoltage
205-272-335shy145-170-237 -321-399
420-533 170-237 -300shy
385-498
26-32-38-44-49Indoor Unit
Outdoor Unit
194-240-304shy385-498
28-33-38-44-49
388-469-628-738
347-420-562-661
34-41-49-53
CD n 3-i n OJ 0389-639-848 o J350-576-763 V)
32-42-49
2 9 43Refrigerant
FV50S (040) NE022 (295)
Refrigerant Pipe
Refrigerant Pipe Length
Connection IndoorOutdoor FlaredFlared
Method
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling) - Indoor DB 80deg F(27deg e) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice
LIMITED WARRANTY ISeven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 11
~ (MSZ-FE12NA MODEL SHOWN)
MSZ HEAT PUMP TAX
CREDIT
Model Name
Cooling 1
Indoor Unit Outdoor Unit
Rated Capacity Btuh
MSZ-GE09NA MUZ-GE09NA
9000
MSZ-FE09NA HshyMUZ-FE09NA bull
9000
MSZ-GE12NA MUZ-GE12NA
12000
MSZ-FE12NA MUZ-FE12NA
12000
H-bull MSZ-G MUZ-G
14000
Capacity Range Btuh 3800-12200 2800-9000 3800-13600 2800-12000 3100-18200
Total Input W 660 (205-1200) 580 (160-650) 960 (205-1300) 930 (160-960) 1080 (160-2000)
Energy Efficiency SEER 21 26 205 23 21
Moisture Removal Pintsh 15 21 25 29 27
Sensible Heat Factor 082 076 074 073 080
Heating at 47deg F 2
Rated Capacity Btuh 10900 10900 14400 13600 18000
Capacity Range Btuh 4500-14100 3000-18000 5500-18100 3000-21000 4800-20900
Total Input W 760 (255-1200) 710 (150-2250) 1170 (340-1660) 950 (150-2250) 1600 (270-2010) HSPF (IV) BtuhlW 10 106 10
Heating at 17deg F3 Rated Capacity Btuh 6600 6700 8800 8300 11300 Rated Total Input W 700 650 900 800 1150 Maximum Capacity Btuh 8700 12500 11200 13600 15900
Heating at 5deg F Maximum Capacity Btuh 7061 10900 9194 12500 13022
Power Supply Phase Cycle Voltage 1-phase 60Hz 208 230V 4
Voltage
Indoor - Outdoor S1 - S2 AC 208 230V
Indoor - Outdoor S2 - S3 DC12-24V
Indoor - Remote Controller Wireless Type (Optional Wired Controller DC 12V)
Indoor Unit
MCA A 10
Fan Motor FLA 076
Airflow at Cooling (Lo-Med-Hi-Super HI-Powerful) 1
DRY (CFM) 145-170-237-321-399 162-226-339-381 145-170-237-321-399 162-226-381-410 205-272-335-420-533
WET (CFM) 109-134-201-286-364 144-202-307-343 109-134-201-286-364 144-202-350-367 170-237-300-385-498
Airflow at Heating (Lo-Med-Hi-Super HI-Powerful) 2
WET (CFM) 145-170-237-321-406 166-240-367-381 145-170-237-321-406 166-240-399-420 205-247 -304-367-463
Sound Pressure Level at Cooling (Lo-Med-Hi-Super HI-Powerful) 1
dB(A) 19-22-30-37-43 22-31-39-42 19-22-30-37-45 22-33-43-45 26-32-38-44-49
Sound Pressure Level at Heating (Lo-Med-Hi-Super HI-Powerful) 2
dB(A) 19-22-30-37-43 22-31-40-42 19-22-30-37-43 22-33-43-44 26-30-35-40-46
External Finish Color Munsell No 10Y 92 I 02
Dimension Unit
Wln 31-716 31-38 31-716 31-38 31-716
0 In 9-118 10-18 9-18 10-18 9-18
H In 11-58
Weight Unit Lbs 22 27 22 27 22
Field Drainpipe Size 00 In 58
Outdoor Unit
MCA A 12
MOCP A 15
Fan Motor FLA 050 056 050 056 050
Compressor
lVIodel (Type) DC INVERTER-driven DC INVERTER-driven Twin
Rotary DC INVERTER-driven DC IIWERTER-driven Twin Rotary
RLA 66 86 66 86 74
LRA 82 108 82 108 93
Airflow (CoolingHeating) CFM 11511225 1102 11187 12291172 1102 11187 12431229 Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(A) 46 48 49 48 49
Sound Pressure Level at Heating 2 dB(A) 50 49 51 49 51
External Finish Color Munsell No 3Y 78 11
Dimensions
Wln 31-12
0 In 11-114
H In 21-58
Weight Lbs 66 80 77 80
Remote Controller Type Wireless Remote (Optional Wired Controller)
Refrigerant
Type R410A
Charge Lbs Oz 112 29
Oil Type (fl oz) NE022 (108) NE022 (152)
Refrigerant Pipe Gas Side 00 In 38 12
Liquid Side 00 In 14 14
Refrigerant Pipe Length Height Difference (Max) Ft 40
Length (Max) Ft 65 I
Connection Method IndoorOutdoor FlaredFlared
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg e) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg e) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg e) Outdoor DB 47deg F(8deg e) WB 43deg F(6deg e) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg e) Outdoor DB 17deg F(-8deg e) WB 15deg F(-9deg e) 4 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice
12 +MITSUBISHI ELECTRIC LIMITED WARRANTY ISeven-year warranty on compressor Five-year warranty on parts
- shy(MSY(Z)-D30NA MODEL SHOWN)
Vl J
09 (I)
I
N o J (I)
s Vl N Vl
-0 (I) n 31 n OJ 0 o J V)
Model Name Indoor Unit MSZ-GE18NA MSZ-FE18N MSZ-GE24NA MSZ-D30NA MSZ-D36NA
Outdoor Unit MUZ-GE18NA MUZ-FE18rK MUZ-GE24NA MUZ-D30NA MUZ-D36NA Rated Capacity Btuh 17200 18000 22500 30700 33200
Capacity Range Btuh 3700-18700 8200-25200 8200-31400 9800-30700 9800-33200
Total Input W 1640 (240-2070) 1270 (570-2280) 1800 (570- 3580) 3850 (620-3850) 4360 (620-4360) Cooling 1
Energy Efficiency SEER 192 202 190 145
Moisture Removal Pintsh 46 27 27 99 11 3
Sensible Heat Factor 071 084 075 064 062
Rated Capacity Btuh 21600 21600 27600 32600 35200
Capacity Range Btuh 3500-25200 7500-29700 7500-36900 8700-34000 8700-36000 Heating at 47deg F 2
Total Input W 1900 (230-2680) 1540 (520-2240) 2340 (520- 3650) 3360 (520-3600) 3840 (520-4100)
HSPF (Region IV) BtuhIW 10 103 10 82
Rated Capacity Btuh 13400 11700 16000 19500 21800
Heating at 17deg F 3 Total Input W 1450 2180 3290 2400 2820
Maximum Capacity Btuh 17200 19300 24600 20800 22800 Heating at 5deg F
Maximum Capacity Btuh 13562 21 600 21160 16305 19090
Power Supply Phase Cycle Voltage 1 Phase 60Hz 208230V 4
Indoor - Outdoor S1-S2 AC 208 230V Voltage Indoor - Outdoor S2-S3 DC12-24
Indoor - Remote Controller Wireless Type (Optional Wired Controller DC12V) MCA A 10 Fan Motor FLA 076
DRY (CFM) 230-275-339-420-533 388-469-628-738 388-469-628-738 389-639-848 Airilow (Cool) (Lo-Med-Hi-Super HI-Poweriul) 1
WET (CFM) 194-240-304-385-498 347-420-562-661 347-420-562-661 350-576-763
Airilow (Heat) (Lo-Med-Hi-Super HI-Poweriul) 2 DRY (CFM) 230-275-339-431-512 388-469-628-738 388-469-628-738 445-639-848
Sound Pressure Level (Cooling) (Lo-Med-Hi-Super 28-33-38-44-49 34-41-49-53 34-41-49-53 32-42-49
HI-Poweriul) 1
Sound Pressure Level (Heating) (Lo-Med-Hi-Super dB(A)
Indoor Unit 28-33-38-43-48 32-41-49-52 32-41-49-52 34-42-49-49HI-Poweriul) 2
External Finish Color Munsell No 1 OY 9202
W In 31-716 43-516 46-116
Dimension Unit D In 9-18 9-38 11-58
H In 11-5 8 12-1316 14-38
Weight Unit Lbs 22 37 40
Field Drainpipe Size OD In 58
MCA A 14 171 21
MOCP A 15 20 25
Fan Motor FLA 093
Model (Type) DC INVERTER-driven Twin Rotary
Compressor RLA 100 129 16
LRA 125 161 20
Airilow CFM 1730 1659 17691 701 1941
Outdoor Unit Refrigerant Control Linear Ex~ansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(A) 54 55 56
Sound Pressure Level at Heating 2 dB(A) 56 55 57
External Finish Color Munsell No 3Y 7811
W In 33-116
Dimensions D In 13
H In 33-716 34-58 33-716
Weight Lbs 119 141
Remote Controller Type Wireless Remote (Optional Wired Controller)
Type R410A
Refrigerant Charge Lbs Oz 3 7 43 410
Oil Type (FI Oz) NE022 (152) FV50S (135) NE022 (29)
Gas Side OD 12 58In
Refrigerant Pipe Liquid Side OD 14 38
Height Difference (Max) 50
Length (Max) Ft
100 I Connection
Mpthon IndoorOutdoor Flared Flared
NOTESTest conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg C) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F (24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F(6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 17deg F(-8deg C) WB 15deg F(-9deg C) 4 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice LIMITED WARRANTY ISeven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 13
(SEZ-KD12NA MODEL SHOWN)
SEZ HEAT PUMP TAX
CREDIT
Model Name Indoor Unit SEZ-KD09NA4 SEZ-KD12NA4 SEZ-KD15NA4 SEZ-KD18NA4
Outdoor Unit SUZ-KA09NA SUZ-KA12NA SUZ-KA15NA SUZ-KA18NA Rated Capacity Btuh 8100 11500 14100 17200
Capacity Range Btuh 3800-10900 3800-13300 3800-17000 3800-19000
Cooling 1 Total Input W 670 920 1170 1380
Energy Efficiency SEER 15 16 155 175 Moisture Removal Pintsh 15 24 26 34 Sensible Heat Factor 080 076 080 079
Rated Capacity Btuh 10900 13600 18000 21600
Heating at 4YO F 2 Capacity Range Btuh 4800-14100 4800-16400 4800-21100 4800-24900
Total Input W 1020 1140 1500 1700 HSPF(lV) BtuhIW 100 Rated Capacity Btuh 6700 9000 11900 13100
Heating at 1 yo F 3 Rated Total Input W 810 920 1200 1350 Maximum Capacity Btuh 7300 9800 13700 15000
Power Supply Phase Cycle Voltage 1 Phase 60Hz 208 230V 4 Indoor - Outdoor S1 - S2 AC 208-230V
Voltage Indoor - Outdoor S2 - S3 DC 12-24V Indoor - Remote Controller See optional accessories chart (pg 26 and 27) MCA A 1 Fan Motor FLA 051 057 074
Airflow (Lo-Med-Hi) DRY (CFM) 194-247-317 247-317-388 353-441-529 423-529-635
WET (CFM) 174-222-285 222-285-349 317 -396-4 76 381-476-572 External Static Pressure 3 In wG 002-006-014-020 Sound Pressure Level dB(A) 23-26-30 23-28-33 30-34-37 30-34-38
Indoor Unit External Finish Galvanized-Steel Sheets
W In 31-18 39 46-78
Dimension Unit D In 27-916
H In 7-78
Weight Unit Lbs 42 50 54 62 Field Drainpipe Size 00 In 1-14
MCA A 12 14
MOCP A 15 Fan Motor FLA 050 093
Model DC Inverter DC Inverter Twin Rotary
I (Type)Compressor
RLA 66 74 10
LRA 82 93 125
Airflow (CoolingHeating) CFM 11511225 12291172 1 2431 229 17301659
Outdoor Unit Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(A) 46 49 54 Sound Pressure Level at Heating 2 dB(A) 50 51 56
External Finish Color Munsell No 3Y 7811
W In 31-12 33-16
Dimensions D In 11-14 13
H In 21-58 33-716
Weight Lbs 66 77 80 119 Remote Controller Type See optional accessories chart (pg 26 and 27)
Type R410A
Refrigerant Charge Lbs Oz 116 2 9
Type (fl Oil
oz) NE022 (108)
Refrigerant Pipe Gas Side OD In 38 Liquid Side 00 In 14
Refrigerant Pipe Height Difference (Max) Ft 40 Length Length (Max) Ft 65
Connection IndoorOutdoor FlaredFlared
Method
316
NE022 (152)
12
50
100
I
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg C) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F(8deg C) WB 43deg F(6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 17deg F(-8deg C) WB 15deg F(-9deg C) 4 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
14 MITSUBISHI ELECTRIC
SEZ STATIC PERFORMANCE CURVES (SEZ-KD12NA4 MODEL SHOWN)
SEZ-KD09NA4 SEZ-KD09NA4 (External static pressure O06[inwG]) 208230V 60Hz
[020] V L
5 [016
~l [0 12
]
SEZ-KD09NA4
~ ltij
~ [008
Jj
]
]
[004J ~
V V Middle
Low
V
19h
Rated point
1
o [141] [176J 1212) )247] [282J [318]
Airll ow rat e [CFM)
SEZ-KD12NA4 (External static pressure O06[inwG]) 208230V 60Hz
[020
5 [016
]
]
[353J
Limit
]
~ V
~ [ [0 12
u ltijJ[008
[004
]
_V ]~ Low
V
k-iddle
Rated POint
o [212) [247] [2 82] [318] [353] [388]
Airtlow rate [C FM]
SEZ-KD1SNA4 (External static pressure O06[inwGl) 208230V 60Hz
[424)
1020]
5 [016
~ ~ [012
~ ltij
~ [008
Jj
J
)
]
[004 ]
o
VV V [ Low
VV
vV High
Middle
I Rated point
[282] [318) [353] [388] [424] [459] [494] [530] [565J
Airllow rat e [CFM]
SEZ-KD18NA4 (External static pressure O06[inwG]) 208230V 60Hz
50 10 20]
] 40
5 [016
s 30 [ (012 )
ltij 20 ~ [008 )~Jj
10 [004]
V
Low
v Limit
rIV High
V [ Middle
~
1
Rated point
f318) [353) [388] [424] [459] [494] [530] [565] [600] [636] [671 )
Airllow rate [CFM]
(External static pressure O14[inwG]) 208230V 60Hz 80
[0 32
70 [028
5 60 [024
20 [0 08
10 [004
]
]
J
]
]
J
]V
]
U~it
V
k
High
~V Rated POI~1 V Middle Low
~
o [141] [1 76] 12121 )247J [282] [318]
Airtlow rate [CFM)
SEZ-KD12NA4 (External stat ic pressure O14[inwG]) 208230V 60Hz
[032]
[028J
5
[353]
J
~ [024
-~ [020] V-is
J V Il Hi9h Rated point
[016
~ ]
V V1 Middle
~ [012
[008]~
[004)
o [212)
[247)
SEZ-KD1SNA4
Low r
[282] [31 8) [353]
Airllow rale [CFM]
[388]
(External static pressure O14(inwG]) 208230V 60Hz
[032J
[424
]
2 V[028
5 [024]
V-i
] V High i [020
] K
Middle Rated point [0 16
g ]
~ -
QJj [0 12
J Low
[008
] I
~
[004
o [282J [318) [353J [388J [424) [459] [4 94] [530) [565)
Airt low rate [CFM]
SEZ-KD18NA4 (External statiC pressure O14(inwG]) 208230V 60Hz
1032
1028
~ 1024
-~ [0 20
is (0 16 ltij E ~ [012
(008
(004
o
I
]
]
)
]
)vlt ]
]
~ V
VV
Low
Limit
V
Ji9h
Middle l
Rated point
1 t
1
~ [318] [353] [388] [424] [459) [4 94] [530) [565) [600] [636] [671)
Airllow rate [CFM]
(External static pressure O20(inwG]) 208230V 60Hz
[032 ]
[028 J
5 [024
~ [020
is [016
1 [012Jj
[008
[004
J
]
]
] )
]
V Low
umz V High
~V
Rated point
Middle
1
[141] [176] [212) [247) [282) [318) [353J
Airtlow rat e [CFM]
SEZ-KD12NA4 (External static pressure O20(inwG]) 208230V 60H z
[032 ] LLimit
)
[0 28
5 ]
V
[024 -~ [020] V Rated point
Highis ~
) V
bull Middle
]~V I
[016
~ ~ [012
] Low
[008
]
[0 04
o [212) [247] [282] [318] [353] [388] [424]
Airllow rate [CFM]
SEZ-KD1SNA4 (External static pressure O20(inwG]) 208230V 60Hz
80 [032 ]
70 [0 28
~ [ O~~ -
ltij
E 30 ~ [0 12
20 [008
10 [004
o
)
J
]
]
JV
J
J
Limit V
LV High
V ~
K Rated point
Middle
VV 1gt
Low
I-
~ [282) [318) (353] (388) (424) 1459] [494] 15301 [565)
Airtlow rate [CFM]
SEZ-KD18NA4 (External static pressure O20[inwG]) 208230V 60Hz
[032
[028
~ [024sect
I [020
~ [016
~ Jj [0 12
[008
[004
o
]
)
]
]
]
~ )
]
]
1V
V 1
V
Low
1 limit
~~~ I ~~ High
~ R~ted pOini
Middle
1 1 -
[31 8) [353] [388] [424) [459] [494] [530] (565) [600] (636) [671J
Airllow rate [CFM)
Vl ~ ca (I)
I
N o ~ (I)
Vl m N Vl
-0 (I) n 3-i n QJ ~ o ~ tn
Note ESP 20S230V 60 Hz See manual for Static Performance Curve including 002 in WG
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts ~MITSUBISH[ ELECTRIC 15
SLZ HEAT PUMP (SLZ-KA12NA MODEL SHOWN)
Model Name Indoor Unit SLZ-KA09NA SLZ-KA12NA SLZ-KA15NA
Outdoor Unit SUZ-KA09NA SUZ-KA12NA SUZ-KA15NA Rated Capacity Btuh 8400 11100 15000
Capacity Range Btuh 3100-10900 3100-13300 3100-22200
Cooling 1 Total Input W 700 920 1460
Energy Efficiency SEER 15 154 16 Moisture Removal Pintsh 12 23 45 Sensible Heat Factor 080 076 080
Rated Capacity Btuh 10900 13 600 18000
Heating at 4r F 2 Capacity Range Btuh 3100-14100 3100-17100 3100-17100 Total Input W 930 1180 1950 HSPF (IV) BtuhIW 96 Rated Capacity Btuh 6200 8300 10200
Heating at 17deg F 3 Rated Total Input W 740 930 1310 Maximum Capacity Btuh 8300 10200 12000
Power Supply Phase Cycle Voltage 1 Phase 60Hz 208 230V 4 Indoor - Outdoor S1 - S2 AC 208-230V
Voltage Indoor - Outdoor S2 - S3 DC 12-24V
Indoor - Remote Controller See optional accessories chart (pg 26 and 27) MCA A 1 Fan Motor FLA 023 028 028
Airflow (Lo-Med-Hi) DRY (CFM) 280-320-350 280-320-390 280-320-390
WET (CFM) 250-290-320 250-290-350 250-290-350
Sound Pressure Level dB(Al 29-32-38 30-34-39 31-35-40
Indoor Unit External Finish Galvanized-Steel Sheets Grille Munsell 64Y 8904
W In 22-7 16 (25-58)
Dimension Unit (Grille) D In 22-716 (25-58
H In 8-316 (1316)
Weight Unit (Grille) Lbs 36 (7) Field Drainpipe Size 0 0 In 1-14 MCA A 12 MOCP A 15 Fan Motor FLA 050
Model (Type) DC INVERTER-driven DC INVERTER-driven
Compressor RLA 66
LRA 82
Airflow (CoolingHeating) CFM 11511225 1 229 1 172
Outdoor Unit Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(AJ 46 49 Sound Pressure Level at Heating 2 dB(AJ 50 51
External Finish Color Munsell No 3Y 781 1
W In 31 shy12
Dimensions 0 In 11-14
H In 21-58
Weight Lbs 66 77
~e R410A
Refrigerant Charge Lbs Oz 1 16
Oil Type (fl oz) NE022 108)
Refrigerant Pipe Gas Side 0 0 In 38 Liquid Side 00 In 14
Height Difference (Max) Ft 40 Refrigerant Pipe Length
Length (Max) Ft 65
Connection Method IndoorOutdoor FlaredFlared
29
Twin Rotary 74
93
12431 229
80
NE022 l152) 12
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg C) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F(8deg C) WB 43deg F(6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 17deg F(-8deg C) WB 15deg F(-9deg C) 4 Indoor units receive power from outdoor units through field-supplied interconnectedwiring Specifications are subject to change without notice
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
16 MITSUBISHI ELECTRIC
MHK1 WIRELESS REMOTE CONTROLLER KIT Exclusive for INVERTER-driven Mr Slimreg Systems VlWireless Technology a J
JMITSUBISHI ELECTRIC
Wireless Receiver
MHK1 Kit includes
09 mMRCH1 WIRELESS REMOTE CONTROLLER I Nbull Backlit easy-to-read display o
bull Dual setpoint control with system changeover J m
bull Enabled with RedLlNKTM reliability
bull Compatible with MCCH1 Vl Portable Central Controller m
N bull Installs Anywhere Vl
MFH1 WIRELESS RECEIVER N Vlbull Required for MRCH1 Wireless
CRemote Controller m bull Enabled with RedLiNK reliability n
31 n OJ o J en
SEZ and SLZ 11 systems with SUZ outdoor unit
Function Description
ONOFF OnOff operation for a single indoor unit
Operation Mode Cool I Drying I Auto I Heat I Fan only Available operation modes dependant on connected system
Temperature Setting Set temperature from 50degF - 8rF depending on operation mode and connected system
System Changeover Deadband Value 2-8degF
Schedule Operation 5-25-1-1
Fan Speed Setting HiMid-2Mid-1 IlowlAuto Available fan speed settings dependant on connected system
Air Flow Direction Setting Air flow angles 100deg - 80deg - 60deg - 40deg and oscilate Available air flow direction settings dependant on connected system
PermitProhibit Function Individual prohibit operations for each remote controller function (ONI OFF Set Temperature and Operation Mode)
Space Temperature Displays the measured space temperature
Error Indication Displays error code
Display Outside Temperature and Humidity
Requires optional MOS1 Outside Air Sensor
Dimensions - ryv x D x H) Remote Controller 5-316 x 1-12 x 3-916 Receiver 3-14 x 1-516 x 6-716
Operating Ambient Temperature Remote Controller 32 - 120degF Receiver -40 - 165degF
Operating Ambient Humidity Remote Controller 5 - 90 RH (non-condensing) Receiver 5 - 90 RH (non-condensing)
Power Supply 2 AA batteries
MRCH1 MIFH1 MRC1
Wireless Wall-Mounted Remote Controllers Wireless Receiver Cable
Accessories MCCH1 MOS1
Portable Central Controllers Outside Air Sensor
MITSUBISHI ELECTRIC 17
MULTIPLE ROOMS WITH INDIVIDUAL CONTROL FROM A SINGLE SYSTEM Enjoy ideal levels of comfort in the rooms you use most with our multi-room system Each room (zone) operates independently People in different rooms - the kitchen master bedroom or living room - can enjoy temperature settings that make each of them most comfortable
If you re looking for a complete comfort solution for several different rooms the MXZ multi-room system is the right choice The system is flexible enough to conform to a particular cooling and heating need and offers numerous different indoor unit combinations In addition up to eight indoor units can be connected to one outdoor unit Now with a SEZ horizontal ducted unit and a MFZ floorshystanding unit homeowners can enjoy an even greater range of zoning options provided by an MXZ system
An MXZ multi-room system is an excellent choice for supplementing capacity to a current system conditioning newly furnished spaces or new additions and replacing a system within a home Homeowners can also benefit from lower energy costs year-round while staying comfortable thanks to Mitsubishi Electrics energy-efficient technologies that are a part of every system that we make
To add to the level of energy efficiency the MXZ -2B20NA and MXZ -3B24NA systems qualify for both ENERGY STARreg and the federal tax credit (See details on page 21 for applicable indoor unit combinations)
At right a single level home with several system types represented (For illustrative purposes only)
MFZ Floor-Standing Indoor Units for MXZ Heat Pump Systems
Floor-standing indoor unit mounts three inches above the floor and has front panel access to the filter for ease of cleaning
The MFZ units provide energy-efficient solutions to provide personalized comfort for difficult areas that may be smaller or dont have usable space on the walls
MFZ units on MXZ systems include the following features bull Top and bottom discharge vanes bull Hot-start technology bull Quiet operation bull Wireless remote control (optional wall-mounted controller)
18 MITSUBISHI ELECTRIC
MSZ Wall-Mounted Indoor Units for MXZ Heat Pump Systems
Providing a wide range of cooling and heating capacities each wall-mounted indoor unit mounts high on a wall and connects to a branch box or the outdoor unit by a refrigerant line run via a 3 hole The MSZ units provide highly efficient solutions to cooling and heating needs and provide personalized comfort for the individual zones in which they are installed
MSZ units on MXZ systems include the following features bull Sleek flat panel design bull Hot-start technology bull Quiet operation bull i-seeM sensor technology (MSZ-FE0912NA models only) bull Enhanced filtration system (MSZ-FE0912NA models only) bull Wireless remote control (optional wired wall-mounted controller)
SLZ Ceiling-Recessed Indoor Units for MXZ Heat Pump Systems
The new SLZ-KA ceiling casette systems offer a wide air-flow pattern for better air distribution
offered to your customers Installation can be done in a hard ceiling (with a access panel for servicing) or placed into a 2x2 drop ceiling With a built-in drain lift mechanism for condensate
removal and a 4 ventilation air intake knockout option the SLZ is ready to handle a variety of installation needs
SLZ units on MXZ systems include the following features bull Wide air-flow pattern for better air distibution bull 4 ventillation air intake knockout bull Built-in condensate lift mechanism bull Wireless RedLlNKTM remote controller
SEZ Horizontal Ducted Indoor Units for MXZ Heat Pump Systems
SEZ ducted units can provide split air-conditioning system advantages with the added benefit of being concealed to provide virtually no visual footprint within the conditioned space other than a register and grille for the air to flow With the use of short run ductwork these units can provide comfort to a single room that needs air dispersed evenly throughout the space unusually shaped rooms and adjacent rooms
The SEZ unit on MXZ systems include the fOllvowin fatures _
g~e~~~~==Zl[bull Concealed design for short-run ductwork bull Quiet operation bull Built-in condensate lift mechanism
JMITSUBISHI ELECTRIC 19
s c t
I
N o J ro o ltro ~ ro ~
DIAMOND COMFORT MXZ MULTI-ZONE SYSTEMS MXZ-B Series multi-zone systems provide personalized comfort control and energy efficiency in up to eight rooms with only a single outdoor unit The MXZ-B Series system features include
bull Individual zone control bull Mix and match flexibility of indoor unit styles and combinations bull A wide range of indoor unit capacities that match the room size and requirements bull Flexible design options to tackle the most challenging multi-room installations bull Efficient systems including three systems [mxz series] that meet energy starltID and
federal tax credit requirements bull Simple quick and cost-effective installation keeps install costs down on new construction
and disruption to a minimum on renovations and refits
Efficiency and performance ratings depend on the number style and capacity of the indoor units installed with each Multi-Zone System
MXZ -2 B20 NA - 1 (2 1 ) MXZ -3 B24 NA (2 13 1) Ou tdoo r Unit Outdoor Uni t
MSZ-GE09NA Indoor Units
SEZ-KD12NA Indoor Unit
MSZ- GE06NA
~~~~li
(At least two indoor units MSZ-GE06NAIndoor Unit must be installed) Indoor Unit
(Two indoor units must be installed )
MXZ -3 B30 NA (2 1 3 1) Outdoor Unit
SEZ-KD12NA Indoor Unit
~~~i
(At least two indoor units MSZ-GE06NA must be installed)
Indoor Unit ~
MFZ- KD12NA Indoor Unit
MXZ-8B48NA (2 1-8 1) Outdoor Unit
(At least two indoor units
must be installed)
(At least two indoor units must be installed)
MFZ-KD09NA Indoor Units
MSZ-GE09NA Indoor Units
SEZ-KD12NA Indoor Unit
MSZ INDOOR UNIT
MSZ-FE18NA
PEAD HORIZONTAL -DUCTED INDOOR UNIT
PEAD-A24AA
MSZ INDOOR UNIT SEZ HORIZONTAL-DUCTED MSZ-FE18NA
INDOOR UNIT MFZ FLOOR-STANDING SEZ-KD18NA INDOOR UNIT
MFZ-KA12NA
20 AMITSUBISHI ELECTRIC
MULTI-ROOM MXZ-8 INVERTER HEAT PUMP R
Model Name Outdoor Unit MXZ-2B20NA-1 5 MXZ-3B24NA 6 MXZ-3B30NA MXZ-4B36NA 7
Indoor Unit
Cooling 1 Non-ductedl Ducted
Rated Capacity Btuh 1800020000 2200023600 28400127400 3540034400
Capacity Range Btuh 7800-20000 12600-25500 12600-28400 12600-36400
Total Input W 2190 (630-219QL 2460 (1000-2950) 3330 l1 000-3330) 3 940 (1 000-4020)
Heating at 4JO F 2 Non-ductedl Ducted
Rated Capacity Btuh 2200022000 2500024600 2860027600 3600034400
Capacity Range Btuh 8500-25500 11400-30600 11 400-36000 11400-43000
Total Input W 2620 (520-2620) 1900 (740-2600) 2220 (740-2820) 3100 (740-3940)
Heating at 1JO F 3 Non-ductedl Ducted
Rated Capacity Btuh 1250012500 1400014000 1600015100 2220020300
Rated Total Input W 13501430 13801570 21202 140 24302340
Maximum Capacity Btu h 1450014500 1880017000 1880018000 2460025400
Maximum Total Inl2ut W 15001590 21202230 21202140 33403450
Power Supply Phase Cycle Voltage 1-phase 60Hz 2081 230V 8
Voltage Indoor shy Outdoor S1 - S2 AC 2081 230V
Indoor shy Outdoor S2 - S3 DC12-24V
Outdoor Unit 4
MCA A 15 19
MOCP A 20
Fan Motor FLA 096 093
Compressor
Model (Type)
DC INVERTER-driven Twin Rotary
RLA 101 11 144
LRA 15
Airflow (CoolingHeating) CFM 14851 640 20681605 13651605 20682068
Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1
dB(A) 49 54 49 54
Sound Pressure Level at Heating 2
dB(A) 51 49 57
External Finish Color Munsell No 30Y 781 1
Dimensions
W In 33-116 35-716
D In 13 12-58
H In 27-1516 35-7116
Weight Lbs 130 150 153
Indoor Unit No of Units 2 23 23 234
Remote Controller Type Associated with the Indoor Unit
Refrigerant
Type R410A
Charge Lbs Oz 515 7 11 813
Oil Type (fl oz)
NE022 (237) NE022 (294)
Refrigerant Pipe Gas Side 00 In AB 38 A 12 BC 38 A 12 BCD 38
Liquid Side 00 In 14
Refrigerant Pipe Length Height Difference (Max) Ft 4933 9
Length (Max) Ft 164 (A+B) 230 (A+B+C) 230 (A+B+C+D)
Connection Method IndoorOutdoor FlaredlFlared
Compatible with the MSZ-A MSZ-GA MSZ-FD MSZ-FE MSZ-GE MFZ-KA and SEZ-KD series indoor units (PLA-18 amp PCA-24 on the MXZ-MXZ-3B PLA-24 amp PCA-24 on the MXZ-4B)
NOTES Test conditions are based on AHRI 210240 One indoor unit is turned off during low-speed testing under the new test conditions Systems actually exhibit higher energy efficiencies during normal operation
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F (35deg C) WB 75deg F (24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F (6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 600 F (160 C) Outdoor DB 17deg F (_80 C) WB 150 F (_90 C) 4 Refer to pages 12 and 13 for Indoor Unit specifications 5 Data from combination of two Indoor Units 9000 Btuh (non-ducted) or one 9000 Btuh and one 12000 Btuh (ducted) 6 Data from combination of two Indoor Units 6000 Btuh and one 9000 Btuh (non-ducted) or three 9000 Btuh (ducted) 7 Data from combination of four Indoor Units 9000 Btuh (non-ducted and ducted) 8 Indoor units receive power from outdoor units through field-supplied interconnected wiring 9 49 Applies to installations where the outdoor unit is installed below the indoor unit
Power factor equals 97 percent
Specifications are subject to change without notice
MULTI-ZONE ENERGY STAR AND TAX CREDIT SYSTEMS
Model Indoor Unit Combinations SEER HSPF
MXZ-2B20NA-1 2 x MSZ- GE09NA 18 8 9
MXZ- 3B24NA 2 x MSZ- GE06NA 1 x MSZshy GE09NA
17 5 9 3
MXZ- 3B24NA 2 x MSZ-GE06NA 1 x MSZ- GE12NA
17 5 93
For more details on all ENERGY STAR and tax credit systems go to wwwmitsubishicomfortcomtaxcredit
See page 25 for additional info on efficiency
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 21
MXZ-8B48NA THE ULTIMATE ZONING SOLUTION
The Mitsubishi Electric MXZ-S84SNA eight-zone unit As a member of the expanding MXZ-B Series of multi-zone systems the MXZ-8B outdoor unit incorporates branch boxes to connect up to eight indoor units MXZ- 8 B48 NA (2 1 - 8 1 )
Outd oor Uni t The INVERTER-driven compressor at the heart of the MXZ-8B -~-- shy
outdoor unit provides variable capacity control allowing the system to adjust to the specific demands of the interior space ~ as needed not the hard start and stop of a traditional system I[iDA Jinstalled in most US homes
The MXZ -8B48NA has only one port on the outdoor unit for two insulated refrigerant lines which run into the home or business to connect to a branch box or boxes From the branch box(es) gas and liquid refrigerant piping run to each of the indoor units The LEV in the branch box(es) controls the refrigerant flow as the load of each zone changes
Through the branch box(es) (the PAC-AKA31 BC three-port andor the PAC-AKA51 BC five-port) the system can connect from two indoor units up to eight indoor units depending on application requirements
The flexibility of the system doesnt stop there The MXZ-8B48NA has rated capacities of 48000 Btuh for cooling and 54000 Btuh for heating System operation however can range from a minimum 12000 Btuh to a maximum 54000 Btuh in cooling and a maximum of 60000 Btuh in heating This type of performance supports a large variety of applications
The MXZ-8B48NA allows for further flexibility because it supports a connected indoor unit capacity from 22 to 130 or 12000 Btuh to a maximum 70200 Btuh depending on diversity
Connectable Indoor Units General Features bull Four-ton outdoor unit can support up to
eight indoor units using branch boxes bull Wide variety of indoor unit styles
-=--_-=-----= - - J _ 1
including wall-mounted floor-standing MSZ-FE09 12 18NA MSZ-GE06 09 12 15 18 24NA ceiling-cassette ducted
bull Individual control up to eight (8) zones using wired or wireless controls
bull Advanced microprocessor control bull Auto restart following a power outage bull Self-check function offering SEZ-KD09 1215 18NA PEAD-A24AA
integrated diagnostics ~--- Jbull Limited warranty five years on parts and
defects and seven years on compressors
SLZ-KA09 1215NA MFZ-KA09 12 18NA
22 MITSUBISHI ELECTRIC LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
I
RMULTI-ROOM MXZ-8 INVERTER HEAT PUMP
Model Name Outdoor Unit MXZ-BB4BNA Cooling 1 Rated Capacity
Non-ducted Rated Total Input Ducted
Maximum Capacity
Rated CapacityHeating at
Rated Total InputIndoor Unit 4JO F 2 Non-
ductedDucted Maximum Capacity
Rated Capacity Heating at
Rated Total InputlJO F 3 Non-ductedDucted Maximum Capacity
Power Supply Phase Cycle Voltage
Indoor - Outdoor Sl - S2 Voltage
Indoor - Outdoor S2 - S3
MCA
Recommended FuseBreaker Size
Fan Motor
Compressor
Airflow (CoolingHeating)
Refrigerant Control
Outdoor Unit Sound Pressure Level at Cooling 1
Sound Pressure Level at Heating 2
External Finish Color
Dimensions
Weight
Total Capacity 22-130
Indoor Unit ModelQuantity
Remote Controller Type
Type
Refrigerant Charge
Oil
Gas Side OD Refrigerant Pipe
Liquid Side OD
Height Difference (Max)
Maximum Distance between (Outdoor unit and farthest indoor unit)
Refrigerant Pipe Length Maximum Pipe Length -Branch box to Indoor Unit
Total Maximum line length between Branch Box and All Connected Indoor Units
Total Length (Max)
Connection Method IndoorOutdoor
Includes both branch boxes if there are two
Branch Boxes (At least one branch box required)
Btuh
W
Btuh
Btuh
W
Btuh
Btuh
W
Btuh
A
A
Type x Quantity
Motor Output (kW)
Model (Type)
Motor Output (kW)
CFM
dB(A)
dB(A)
W In
D In
H In
Lbs
Btuh
Lbs Oz
Type (fl oz)
In
In
Ft
Ft
Ft
Ft
Ft
4800048000
57806470
54000
5400054000
48205270
60000
3300034700
29503390
3660036550
1 Phase 60Hz 208 230V
AC 208-230V
DC12-24V
32
40
Propeller x 2
0086 + 0086
DC INVERTER-driven Scroll
29
3530
Linear Expansion Valve
54
55
Munsell No 3Y 78 11
37-716
13+1-3 16
53-3 16
278
12000 - 70200
600 - 24000 2-8
Associated with Indoor Unit Model
R410A
18 112
FV50S (73)
58
38
6698 4
230
49
197
377
FlaredFlared
Compatible with the MSZ-A MSZ-FO MSZ-FE MSZ-GE MFZ-KA SEZ-KD PLA and PEAD series indoor units
NOTES Test conditions are based on AHRI 210240 One indoor unit is turned off during low-speed testing under the new test conditions Systems actually exhibit higher energy efficiencies during normal operation
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F (35deg C) WB 75deg F (24deg C)
2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 4]0 F (8deg C) WB 43deg F (6deg C)
3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 17deg F (-8deg C) WB 15deg F(-9deg C)
4 66 applies to installations when the outdoor unit is installed below the indoor unit
Power factor equals 97 percent
Specifications are subject to change without notice
Note Maximum installed capacity is the maximum total of all connected indoor units NOT the maximum capacity produced
Only a single Lineset is needed from the outdoor unit to branch box
See page 25 for MXZ-B information on efficiency
Required Branch Boxes for MXZ-SB4BNA (Maximum of 2 branch boxes can be connected to one outdoor unit requires joint MSDD-50AR-E or MSDD-50BR-E)
s c d N o J ro Vl
0 ro n 3i n OJ d o J U)
PAC-AKA51 BC Branch Box
PAC-AKA31 BC Branch Box LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 23
MSZ WALL-MOUNTED INDOOR UNITS (FOR MXZ-8 OUTDOOR UNITS)
R
(MSZ-GE12NA MODEL SHOWN)
-000 IIIIIII 9000 9000 12000 12000 14000 17200
Heating at 4r Rated Capacity Btuh 7200 10900 10900 14400 13600 18000 21600
F2 Power Supply I Phase Cycle Voltage J -phase 60Hz 208 230V 3
Iindoor Outdoor S1 S2 AC 208 230V
Iindoor Outdoor S2 S3 DC12-24V Voltage
Iindoor Remote vomr Iller Wireless Type (Optional Wired vomroller DC 12V)
IMCA A 10 IFan Motor FLA 076
DRY 162-226shy145-170shy
162-226shy205-272shy 230-275shy
Airflow at Cooling (CFM)
145-170-237-321-399 339-381
237 -321shy381-410
335-420shy 339-420shy(Quiet-Lo-Med-Hishy 399 533 533 Super Hi or Lo-Med-
WET 144-202shy109-134shy
144-202shy170-237shy 194-240shy
Fan Hi-Powerful)1 (CFM)
109-134-201-286-364 307-343
201-286shy350-367
300-385shy 304-385shy364 498 498
Airflow at Heating 145-170shy 145-170shy 145-170shy 205-247shy 230-275shy
(Quiet-Lo-Med-Hi- WET 233-321shy 237-321shy
166-240shy237-321shy
166-240shy304-367shy 339-431shy
Super Hi or Lo-Medshy (CFM) 406 406
367 -381 406
399-420 463 512
Hi-Powerful) 2 Sound Pressure Level at Cooling
19-22-30shy 26-32-38shy 28-33-38shy(Quiet-Lo-Med-Hi-Super Hi or Loshy dB(A) 19-22-30-37 -43 22-31-39-42
37-45 22-33-43-45
44-49 44-49Med-Hi-Powerful) 1
Sound Pressure Level at Heating 19-22-30shy 26-30-35shy 28-33-38shy
(Quiet-Lo-Med-Hi-Super Hi or Loshy dB(A) 19-22-30-37 -43 22-31-40-42 37-43
22-23-43-44 40-46 43-48
Med-Hi-Powerful) 2
I External Finish Color Munsell No 10Y 92 02
IWln 31 middot716
Dimension Unit 10 In 9 18 10-18 9middot18 10-18 9-18
IH In 11-58
I Weight Unit ILbs 22 27 22 27 22 I Field Drainpipe ~D lin 58 Remote Con-
Type Wireless Remote (Optional Wired Controller) troller
ITvpe B41QA Refrigerant ~s$ideOD lin 38 Pipe I Liquid Side 00 In 14
Connection IndoorOutdoor FlaredFlared
Method
1~
II 18000 22500
21600 27600
388-469shy 38$-469shy628-738 628-738
347-420shy 347-420shy562-661 562-661
388-469shy 388-469shy628-738 628-738
34-41-49-53 34-41-49-53
32-41-49-52 32-41-49-52
43-516
9-38
12-1316 37
58 38
MXZ-2B20NA is also compatible with the MSZ-A and MSZ-FD series indoor units NOTES Test conditions are based on AHRI 210240
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F(6deg C) 3 Indoor units receive power from outdoor units through field-supplied wiring
Specifications are subject to change without notice LIMITED WARRANTY Seven-year warranty on compressor Five-year warranty on parts For data on specific indoor unit combinations see page 21
SEZ DUCTED INDOOR UNIT (FOR MXZ-8 OUTDOOR UNITS)
I
Notes 1 Cooling-Indoor DS 80deg F(267deg C) WS 67deg F(194deg C) Outdoor DS 95deg F (35deg C) WS 75deg F(239deg C)
2 Heating-Indoor DS 70deg F(211 deg C) WS 60deg F(156deg C) Outdoor DS 47deg F (83deg C) WS 43deg F(61 deg C)
3 External static pressure is factory set to 006 WGAdjustable via the
1---------t---+-----L-------------1~---__I PAR-21MAA
1--_____----__________+-____---L____----~_____________1 4 Indoor units receive power
jE~~~~-------------r----1-----~-~~~~~~~~-----___1 from outdoor units through fieldsupplied interconnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven-year warranty on compressor Five-year
1---------------------+---+------------------------1 warranty on parts
~--__I_~----------+-------~l----------I For data on specific indoor unit combinations see page 21 - 23
I--~------+~-----------~----------r_------------I
- Reference page 17 for SEZ static performance curves
24 MITSUBISHI ELECTRIC
25-30-35-40 26-31-36-41 35-38-42-46
25-30-35-40 28-31-36-41 35-38-42-47
MFZ FLOORLOW WALL INDOOR UNIT (FOR middotMXZ-8 OUTDOOR UNITS)
------shy
-==
Airflow at Heating (CFM) 177-198-219-332 184-201-219-335 261-275-297-434
Voltage
Fan
Airflow at Cooling (Lo-Med-Hi-Super Hi)1
169-205-251-314 251-279-325-394
163-197-241-303 170-207-252-309 241-269-313-379
(Lo-Med-Hi-Super Hi) 2
SLZ CEILING-RECESSED INDOOR UNIT (FOR MXZ-8 OUTDOOR UNITS) EFFICIENCY RATINGS
Voltage
Fan
Galvanized-steel SheetsMunsell 64Y 89 04
Refrigerant Pipe
Model Indoor Unit Type SEER HSPF
MXZ-2B20NA-1
Non-dueted 18 89
Dueted and Non-dueted 1675 87
Dueted 155 85
MXZ-2B20NA-1 ENERGY STAR amp
TAX CREDIT 2 x MSZ-GE09NA 18 89
MXZ-3B24NA
lJon-dueted 175 93
Dueted and Non-dueted 1625 89
Dueted 150 85
MXZ-3B24NA ENERGY STAR amp
TAX CREDIT
2 x MSZ-GE06NA 1 x MSZ-GE09NA
175 93
MXZ-3B24NA ENERGY STAR amp
TAX CREDIT
2 x MSZ-GE06NA 1 x MSZ-GE12NA
175 93
MXZ-3B30NA
Non-dueted 175 105
Dueted and Non-dueted 16 100
Dueted 145 95
MXZ-4B36NA
Non-dueted 18 93
Dueted and Non-dueted 16 5 92
Dueted 150 9 0
MXZ-BB4BNA
Non-dueted 15 87
Dueted and Non-dueted 14B B8
Dueted 147 89
Connection IndoorOutdoor FlaredFlared
Method
Notes 1 Cooling-Indoor DB 80deg F(267deg C) WB 67deg F(194deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(239deg C) 2 Heating-Indoor DB 70deg F(21 1 deg C) WB 60deg F(156deg C) Outdoor DB 47deg F(83deg C) WB 43deg F(61 deg C) 3 Indoor units receive power from outdoor units through field supplied interconnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 25
Notes 1 Cooling-Indoor DB 80deg F(267deg C) WB 67deg F (194deg C) Outdoor DB 95deg F (35deg C)WB 75deg F (239deg C)
2 Heating-Indoor DB 70deg F(211deg C) WB 60deg F (156deg C) Outdoor DB 47 F (83deg C) WB 43deg F (61 deg C)
3 Indoor units receive power from outdoor units through field supplied interco(lnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven -year warranty on compressor Five-year warranty on parts
Presently there is no 1 1 system with the MFZ indoor unit
s c
N o J ro Vl
C ro n ~ n OJ t o J V)
M-SERIES RATING CONDITIONS
INDOOR INTAKE AIR TEMPERATURE
OUTDOOR INTAKE AIR TEMPERATURE
COOLING
MAXIMUM
95degF DB 71 degF WB (MU SUZ MXZ-2B20-13B243B304B36) 90degF DB 73degF WB (MUZY-GE MUZ-FE MUzy-D)
115degF DB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B24 3B304B368B48)
MINIMUM 67degF DB 57degF WB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B201 3B243B304B36)
14degF DB (MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B24 3B304B36) 23degF DB (MXZ-8B48) 6rF DB (MU)
MAXIMUM 80degF DB 6rF WB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B243B304B36)
75degF DB 65degF WB (MUZY-GE MUZY-GA24 MUZ-FE SUZ MXZ-2B20-1 3B243B304B36) 70degF DB (MXZ-8B48)
HEATING
MINIMUM 70degF DB 60degFWB (MUZ-GE MUZ-GA24 MUZ-D MUZ-FE SUZ MXZ-2B20-1 3B243B304B36)
-13degF DB -15degFWB (MUZ-FE) -4degF DB -5degF WB (SUZ MUZ-GE) 5degF DB 4degF WB (MUZ-GA24 MXZ-8B48NA) 6degF DB 5degF WB (MXZ-2B20-1 3B24 3B304B36) 14degF DB 13degFWB (MUZ-D)
MU units operate at intake air temperature down to 10deg Fwith the addition of an ICM-326HM-1 low temperature control
REFRIGERANT TUBING SETS
OPTIONAL ACCESSORIES
REFRIGERANT LINE LENGTH FLARE FLARE _INDOOR UNIT OUTDOOR UNIT
MS-A09WA MU-A09WA 35 MS-A12WA
65 MU-A12WA 35
MSY-GE09NA 65
MUY-GE09NA 40
MSY-GE12NA
65
MUY-GE12NA 65 40
MSY-GE15NA MUY-GE15NA 40
MSY-GE18NA
65
MUY-GE18NA 100 50
MSZ-GE09NA MUZ-GE09NA 65 40
MSZ-GE12NA MUZ-GE12NA 40
MSZ-GE15NA
65
MUZ-GE15NA 40
MSZ-GE18NA
65
MUZ-GE18NA 100 50
MSY-GE24NA MUY-GE24NA 100 50
MSZ-GE24NA MUZ-GE24NA 100 50
MSY-D30NA MUY-D30NA 100 50
MSZ-D30NA MUZ-D30NA 50
MSY-D36NA
100
MUY-D36NA 50
MSZ-D36NA
100
MUZ-D36NA 100 50
MSZ-FE09NA MUZ-FE09NA 40
MSZ-FE12NA
65
MUZ-FE12NA 40
MSZ-GE06091215NA MSZ-FE0912NA
65
MXZ-2B20NA-1 164 4933MFZ-KA0912NA SEZ-KD09 1215NA
MSZ-GE0609 121518NA MSZ-FE091218N MFZ-KA09 1218NA MXZ-3B24NA 164 4933 SEZ -KD09 12 15 18NA SLZ-KA09 12 15NA
MSZ-GE0609 121518NA MSZ-GA24NA MSZ-FE091218NA
MXZ-3B30NA 4933230MFZ-KA091218NA SEZ -KD09 121518NA SLZ-KA09 12 15NA
MSZ-GE0609121518NA MSZ-GE24NA MSZ-FE09 12 18NA
MXZ-4B36NA 230 4933MFZ-KA091218NA SEZ -KD09121518NA SLZ-KA09 12 15NA
MSZ-GE0609 12 15 18NA MSZ-GE24NA MSZ-FE09 12 18NA
MXZ-8B48NA 6698377MFZ-KA091218NA SEZ-KD09121518NA SLZ-KA09 12 15NA
PART NUMBER I USE WITH I DESCRIPTION
Port Adapters and Connection Pipes MAC-A454JP-E MXZ-Series Adapter 38 X12
MAC-A455JP-E MXZ-Series Adapter 12 X38
MAC-A456JP-E MXZ-Series Adapter 12 X58
MSDD-50AR-E MXZ-Series Branch Box Tee Distribution Pipe - Flare Connection between two branch boxes
MSDD-50BR-E MXZ-Series Branch Box Tee Distribution Pipe - Braze Connection between two branch boxes
PAC-493PI MXZ-Series Adapter 14 X38
PAC-SG76RJ-E MXZ-Series Adapter 38 X58
OPTIONAL ACCESSORIES CONTINUED ON NEXT PAGE
49 amp 66 applies to installations in which the outdoor unit is installed below indoor unit26 MITSUBISHI ELECTRIC
OPTIONAL ACCESSORIES (CONTINUED)
PART NUMBER USE WITH DESCRIPTION Control Options and Accessories
M21 JKO 307 M-Series Indoor Units Remote temperature sensor for M-Series indoor units
MAC-397IF-E
MAC-399IF-E
PAC-YU25HT
PAR-21 MM-G
M-Series INVERTER Units
M-Series INVERTER Units
SEZ-KD Indoor Units
Use with P-Series SEZ and for wired M-Series Controller
MA and contact terminal interface - Required to use PAR-21 MM wired wall mount controller with M-Series Systems
CMCN M-NET control adapter I Interface for Mr Slim M-Series MSYZ SEZ I MFZ
External Fan I Heater control relay adapter
Deluxe MA remote controller (Requires MAC-397IF-E for use with M-Series - MSYZ MFZ)
SEZ Wireless remote controller for SEZ units (Requires signal receiver PAR-SA9FA-E)PAR-FL32MA
PAR-SA9CA-E SEZ Wireless signal receiver for SEZ
3-pole disconnect switch 30A 600V turns off power between indoor and outdoor units shyM-SeriesTAZ-MS303
mounts in 2 X 4 utility box and requires standard single gang switch platecover - Low Ambient
ICM-326HM-2 M-Series Non-INVERTER units Low ambient head pressure controller MUZ-GE091215 IVIUZ-FE0912 SUZ-KD091215
Drain pan heaterMAC-640BH-U outdoor unit
MAC-641 BH-U MUZ-GE18 SUZ-KD18 outdoor unit Drain pan heater Filters
MAC-1415FT-E Anti-allergy enzyme filter
MAC-2300FT
MSZlMSY-D3036
Anti -allergy enzyme filter
MAC-308FT
MSYMSZ-GA24
MSZ-FD912 I FE0912 Platinum deodorizing filter
MAC-408FT-E Anti-allergy enzyme filter
MAC-415FT-E
M-Series Indoor Unit - GE09GE12GE15GE18
MFZ-KA Air Cleaning FilterAnti-Aliergy Enzyme Filter
MAC-418FT Anti-allergy enzyme filter
Filter Boxes
FBL1-1
MSZ- FD912 I FE091 2
FB Series Filter Box for SEZ-KD09NA Optional filter box with MERV 8 filters
FB Series Filter Box for SEZ-KD1215NAFBL1-2 Optional filter box with MERV 8 filters
and PEA-A 12M
FBL1-3 FB Series Filter Box for SEZ-KD18NA Optional filter box with MERV 8 filters
Pumps
SI1730-230 MSYZ - 30000 Btuh or greater Sauermann mini condensation pump 230V
S13100-115 MS-Series - non-INVERTER Sauermann mini condensation pump 115V
S13100-230 Sauermann mini condensation pump 230VMSYZ - Less than 30000 Btuh
Miscellaneous BRP-1 Bottom Return Plate for SEZ-KD09NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-2 Bottom Return Plate for SEZ-KD12KD15-NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-3 Bottom Return Plate for SEZ-KD18NA Converts low profile ducted indoor unit from rear return to bottom return
BV12FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderreglnsulated - 12
BV14FSI Use with any Mr Sl im multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 14
BV38FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 38
BV58FSI Use with any IVIr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 58
Condensing unit wall mounting brackets (set of 2) - 440 lb capacity painted steel NOTE CWMB1 IVIU and PU outdoor units Installer is responsible to select and provide suitable hardware and materials to insure proper
mount of bracket to wall
DSD-400N M-Series DiamondBacktrade Platform Stands MUZ-GE18 I MUZ(y)-03036 I
MAC-811DS Drain socket assemblySUZ-KA18
MAC-851DS MUZ-FD0912 Drain socket
MAC-855SG M-Series Air outlet guide
MAC-856SG M-Series Air outlet guide - MXZ-3B24 I 3B30 I 4B36 NA
MAC-860DS MUZ-GE091215 I MUZ-FE0912 Drain socket
MAC-889SG M-Series Air outlet guide- MXZ-2B20NA
MAC-S99SG M-Series Air outlet guide
PAC-SG59SG-E IVIXZ-SB4SNA Air outlet guide (1 piece) I MXZ-SB48NA (Requires 2 pieces)
PAC-SG61 DS-E MXZ-8B4SNA Drain socket - connector
PAC-SG64DP-E MXZ-SB48NA Drain pan
RCMKP1CB lVI-Series Wireless Lockdown bracket for remote controller
lILTRILlTE1 All M-Series Condensing unit mounting pad 16 x 36 x 3
MITSUBISHI ELECTRIC 27
MXZ-8 Series Port Adapter chart Port Adapter Unit Port
Combinations Required Size
MXZ-2B20NA-1
2-zone combinations wi NA
A 38 x both units s12K 14
1-MAC-A454JP-E B 38 x
6+15 14
9+15 1-MAC-A454JP-E
MXZ-3B24NA
All rated 2-zone combina-NA
A 12 x tions 14
All rated 3-zone combina-NA
B 38 x tions 14
C 38 x 14
MXZ-3B30NA
2-zone combinations wi at NA
A 12 x least one unit s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
9 + 24 14
3-zone combinations wi 1-MAC-A455JP-E
all units s12K
All other rated 3-zone NA
comb
MXZ-4B36NA
2-zone combinations wi at NA
A 12 x least one un it s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
6 + 24 14
1-MAC-A456JP-E D 38 x
9 + 24 14
3-zone combinations wi at NA
least two units s12K
3-zone combinations wi 1-MAC-A454JP-E
two units15K
6+6+24 or 6+9+24 1-MAC-A456JP-E
9+9+24 1-MAC-A456JP-E
4-zone combinations wi at 1-MAC-A455JP-E
least three units s12K
6+6+15+15 1-MAC-A454JP-E
6+6+15+15 1-MAC-A454JP-E
Note When using the Pu-A24BA PCA-A24KA or PEAD-A24AA two port adapter will be needed 1-MAC-A456JP-E (12 x 58) A port or 1-PACshySG76RJ-E (38 x 58) B C and D ports and 1-PAC493PI (14 x 38)
28 JMITSUBISHI ELECTRIC
6+6+246+9+24 6+12+249+9+24 9+12+24 or 12+12+24
6+15+24 6+18+24 9+15+249+18+24 12+15+24 or 12+18+24
15+15+24 15+18+24 or 18+18+24
15+24+24 or 18+24+24
Combinations of 4 or more zones
1-PAC-SG76RJ-E
See notes for application below
2
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
See notes for application below
PORT A =38 gas x 14 liquid
PORT B =38 gas x 14 liquid
PORT C =38 gas x 14 liquid
PORT A =38 gas x 14 liquid
PORT B = 38 gas x 14 liquid
PORT C = 38 gas x 14 liquid
PORT D =38 gas x 14 liquid
PORT E =12 gas x 14 liquid
Notes for application bull Check the lineset sizes for your indoor selected models bull Select the branch box or boxes needed for your application bull Compare indoor unit lineset sizes as compared to branch
box sizes bull Connect 15K + indoor units to the larger port on the
(PAC-AKA51 BC) bull Adapt lineset size with appropriate port adapter from
above list bull When using the PU-A24BA or PEAD-A24AA two port
adapter will be needed 1-MAC-A456JP-E (12 x 58) or 1-PAC-SG76RJ-E (38 x 58) and 1-PAC493PI (14 x 38)
-fv
~ DIAMONDBACKtrade
~) BV-Series Ball Valves Model numbers
BV14FFSI BV38FFSI
LISTED 891N REFRIGERANT
BV12FFSI VALVE bull Engineered for Mini-split andBV58FFSI
Multi-split HVAC Units bull Size available 14 38 12 58
bull Full Port Designbull Fully factory assembled bull Furnace brazed and pressure tested bull 700 PSIG Rated bull Each ball valve is equipped with Schraderreg Valve
for refrigerant service bull R-410A Compatible bull Design working pressure 700 PSIG bull Temperature range bull Flare Connections
-40 0 F to +3250 F (-400 C to + 1490
C) bull Forged brass body and seal cap bull Teflonreg seals and gaskets (no synthetic a-rings) bull Seal cap design permits valve operation without
removal of seal cap bull Suitable for use with R-11 R-22 R-123 R-125
R-134A R-236FA R-4202A R-402B R-404A R-407C R-410A R-500 R-502 and R-507
bull One year limited materials and workmanship
Part Number SAE Flare
A B C 0 E F
BV14FFSI 14 619 260 180 122 142 110
BV38FFSI 38 630 267 180 122 142 110
BV12FFSI 12 651 267 180 122 142 110
BV58FFSI 58 664 267 180 128 142 110
Ball valves come With an insulation piece warranty on Ball Valves
~ DIAMONDBACKtrade
~) Platform Stands
Lift the Mitsubishi Electric Comfort Solution
outdoor unit to new heights with our Diamondback Platform Stands
bull Easy to install
bull Available for all sizes of Mr Slim outdoor units
bull Color matched to the outdoor units
Model Number DSD-400N
L 15-34 x W 3-14 x H 3-14
r
)MITSUBISHI ELECTRIC 29
~ DIAMONDBACKtrade LINESETS
~~
Twin-Tube Lineset Insulation Design
bull Balanced outside diameter for uniform coiluncoil position stability
bull Minimum 12 insulation thickness on both tubes Diamondback Advantages include the following features
bull Quick efficient and economical field installation using factory applied Twin Tube insulation and flare connections with flare nuts mounted
bull Correct lengths for reducing waste and time
bull Quality consistency and economy
bull All Diamondback Lineset tubing is tested in accordance with ASTM E243
Filter Boxes
FB Series filter boxes are available in compatible sizes for all Mr Slim horizontal ducted indoor units
FBL 1 filter boxes include 1 thick pleated MERV 8 filter(s) installed Filters are tested in accordance with ANSIASHRAE Standard 522 and Rated Class 2 under UL Standard 900
The cabinet is constructed of non-insulated 20 gauge G-60 galvanized
FBL1-1 FB Series Filter Box for SEZ-KD09NA
FBL1-2 FB Series Filter Box for SEZ-KD12KD15-NA
FBL1-3 FB Series Filter Box for SEZ-KD18NA
steel with foam gasket and provides an air-tight connection to indoor unit and access door Gasket material complies with UL 723 requirements
A screw-through cabinet design for secure attachment to indoor unit and return connection in rear is easily field-converted to bottom return
30 MITSUBISHI ELECTRIC
bull
bull
bull
bull
bull
bull
LINE-HIDE~ Put a professional finish on air-conditioning
installations with an easy-to-install modular
system that beautifies exteriors and
protects Linesets drainlines and wiring
Can be use it indoors too Meets UL94v-O for interior applications
Has snap-on covers and a full selection of couplings elbows T-joints caps and more for any application complex or simple
Offers high-quality PVC with UV inhibitors for outdoor service in all weather conditions
Can be painted with most house paints to match exterior decors
Is not just for HVAC Hide any exterior cabling piping or wiring
Available in four sizes 2-14 3 4 and 6 tubes
Download a brochure at wwwline-hidecom to find out more information
For more information on our CITY MULTI VRF product line visit our website at wwwmitsubishiprocom
_lIJrUlllln ~ ~IIII1 fInll l
~
l bull bull
JMITSUBISHI ELECTRIC 31
How environmentally friendly are Mitsubishi Electric HVAC systems
Mitsubishi Electric is dedicated to providing
environmentally responsible systems that minimize t the environment and our customers ENERGY STAR
PARTNERcarbon footprint
Mitsubishi Elelectrics environmental commitment is
evidenced by the fact that up to 83 of our system
components are recyclable More of our systems are
ENERGY STARreg certified and qualify for the federal tax
credit of up to $300 Local and state government and utility companies may provide tax credits and rebate
opportunities for energy-efficient systems See whats
available in your area by visiting wwwdsireusaorg
How many ENERGY STAR rated systems qualify for the federal tax credit 1 8 systems are ENERGY STAR rated
12 systems qualify for the federal tax credit
Qualified systems include the following products coolingshy
only heat pump H2ireg Hyper-Heating INVERTER heat-pump 2-to-1 and 3-to-1 multi-zone heat pump systems
For details on tax credit requirements visit
wwwmitsubishicomfortcomtaxcredit and for information on available local rebate opportunities from state or utility
companies visit wwwdsireusaorg which is a US Department of Energy information service
bull
Table of Contents
System Overview and Technology 04
System Lineup 08
MSIMSY Air Conditioner Specifications 10
MSZ Heat Pump Specifications 12
SEZ Heat Pump Specifications and Curves 14
SLZ Heat Pump Specifications 16
System Overview and Applications 18
MXZ-B Outdoor Unit Specifications 21
MXZ-8B48 Outdoor Unit Specifications 23
MSZIMFZISEZISLZ Indoor Unit Specifications 24
Rating Conditions Refrigerant Tubing 26
Line Lengths 26
Accessories 26
MXZ Port Adaptors 28
DIAMONDBACKreg Ball Valves 29
DIAMONDBACKregPlatform Stands 29
DIAMONDBACKreg Linesets 30
Filter Boxes 30
LlNE-HIDETM 31
Mitsubishi Electric System Technologies user-friendly zoned residential personalized comfort solutions
Mitsubishi Electric indoor units are easy to install-practically anywhere bull High on the wall to blend into a room without taking up window space bull In the ceiling or below the floor out of sight bull Low on the wall to be unobtrusive
Our systems are the perfect way to cool or heat any single room or multiple rooms in homes or office
Heat-pump systems feature auto mode which automatically switches between cooling and heating in response to changing needs Our systems are nearly silent their fans deliver air quietly and continuously with only a gentle whoosh for constant circulation and filtration For this reason Mitsubishi Electric split-zoning systems have long been the choice for thousands of homes churches schools and libraries across the US and the world
Technology Benefits of Mitsubishi Systems
Features Benefits INVERTER-DRIVEN Maximizes energy savings by making sure only the energy needed COMPRESSORS to cool or heat an area perfectly is used
Installs quickly and easily having no need for major constructionEASY INSTALLATION and remodeling
COMPLETE ZONE Realizes maximum control and energy efficiency by cooling CONTROL and heating only those spaces in use
ADVANCED Creates a comfortable environment no matter what conditions areMICROPROCESSOR outside with our advanced self-monitoring controlsTECHNOLOGY
PERSONAL COMFORT Offers comfort control of temperature fan speed and air direction CONTROL in the specific zone with dedicated controller
WASHABLE LONG-LIFE Improves air quality and saves money by washing ANTI-ALLERGEN FILTERS rather than replacing the filter
AUTO COOUHEAT Switches automatically from cooling to heatingCHANGEOVER (MUZISUZ systems) if desired
ENVIRONMENTALLY Uses R41 OA an environmentally friendly refrigerantFRIENDLY REFRIGERANT
Energy Effic iency Recognized Mitsubishi Electric split-zoning cooling-only and heat pump systems are so energy efficient that currently 18 systems of our INVERTER-driven systems are ENERGY STAR rated This can mean big savings
Add in the federal tax credit and local government and utility rebates and you have an ENERGY STAR opportunity to enjoy comfort at substantial savings PARTNER
For details on qualifying systems go to wwwmitsubishicomfortcomtaxcredit or use your smart phone to scan the tag to the left and go to the page
Visit wwwdsireusaorg for information on available local rebate opportunities from state or utility companies
Get the free app for your smart phone at httpgettagmobi
4 ~MITSUBISHI ELECTRIC
----
MITSUBISHI ELECTRIC 5
Innovative Variable-speed Compressor Technology Sophisticated electronic control systems detect any changes in room or zone temperashyture and-like a cars cruise control-automatically adjust the speed of the outdoor units INVERTER-driven compressor and electronic linear expansion valve (LEV) position for Rprecise capacity control The INVERTER-driven compressor is unlike those found in other systems which only start and stop repetitively Special components within the INVERTER compressor such as high density windings in the motor that increase the magnetic flux and artificial magnets in the rotor to reduce its weight allowi it to operate at higher energy efficiencies with better performance than ever before while producing low sound levels both during start-up and operation
MUZ-FE H2i Heating Capacity at Low Temperatures
120 - -~ I
gc100 --~--~~~~~~--~~~~~~
~ 80~~~~~~-+---~--~~~~--+-~shy()
OJ 60 ------+---j----t---t----t----t---J ~ _ MUZ-FE12NA
Q) 40 _ MUZ-FE18NA I __ UNITARY
~ 20 ---r--+---r--+--~--r-~~~--~~shy
o -13 -4 0 5 10 17 25 30 35 40 47
Outdoor Temperature Degrees FWB
Includes correction for defrost
-
~ l
~ Q) a E ~ 0 ~
o
Heat and Lots of It In addition to the already innovative INVERTER-driven compressor the MSZ -FE high-efficiency systems are also ENERGY STARreg rated and tax credit qualified up to 26 SEER delivering exceptional heating performance
These systems provide heating down to -130 F outdoor ambient and produce up to 100 heating capacity at 50 F MSZ-FE0918 92 capacity at 50 F for MSZ-FE12 Our systems provide year-round comfort in extreme climates while being extremely energy efficient There usually is no need for resistance electric or other supplemental energy-consuming devices with this performance
1seesensor i-seetrade Sensor (MSZ-FE0912NA models only)
The i-see Sensor detects temperature variations in hardshyto-control ceiling and floor areas and controls the airflow up to a wide lateral angle for ultimate comfort (900 angle in cooling mode) By scanning the room and adjusting airflow based on ambient temperature readings MSZ -FE systems achieve superior coolingheating performance with extremely efficient operation
INVERTER model Reaches set point quickly and uniform temperatures are maintained by finely-tuned control of compressor speed
Conventional model Takes longer to reach set point while the temperature is adjusted by switching the compressor off and on consuming additional energy
~ f------------ --_Time ---
Vl l
09shy(I)
I
N 0 l (I)
Vl ltV) (I)
3 0 lt(I)
s (I)
~ OJ l 0 --I (I) n r l 0 0
~
Superior Operation
Advanced Control Technology Through Mitsubishi Electrics advanced controls technology the indoor unit is powered by the outdoor unit Three polarity sensitive wires plus a ground conductor run from the outdoor to the indoor unit providing both power and data communication An advanced wireless remote control is standard on all ductless models An optional wired on-the-wall controller is available for wallshymountedfloor-standing indoor units on INVERTER systems (also requires MAC-397 If adapter) while standard on SEZ -KD ducted units
Quiet Operation Do you hear that No Mitsubishi Electric systems operate at low sound levels our indoor units produce decibels barely at a whisper level Compare to other common sounds
Police siren 118 decibels Circular saw 107 decibels Vacuum cleaner 74 decibels Whisper-tone voice 35 decibels Library reading room 33 decibels Our Indoor Units 19 - 34 decibels (at low speed)
Did you hear that We hope you did
Warm Air No Drafts Our hot-start heat-pump technology provides warmth from the beginning The fan increases in speed as the coil is warmed reducing drafts so when you want warm air you get it
TEMP
88
System Control Mitsubishi Electric offers a comprehensive remote controller that can adjust temperature fan speed and more Choose from four modes COOL HEAT AUTO and DRY The controller also has a 12-hour ONOFF timer for one-button control of your personal comfort
Easy to Maintain With easily accessible filters little or no ductwork to clean and simple wiring between the indoor and outdoor units Mitsubishi Electric systems require minimal maintenance providing another level of convenience
Auto Changeover on Heat-Pump Systems (MUZISUZ outdoor units)
Our heat-pump systems sense whether a space needs cooling or heating and automatically switch modes as needed to maintain a consistent temperature You can set it and forget it
6 MITSUBISHI ELECTRIC
----
Hybrid Catechin pre-filters -- shy
- shy
Total Comfort
Additional Air Circulation With the WIDE VANE or SWING mode available on the MSY(Z)-GE24 D3036NA there is an option for ~~~~lQcnborizontal airflow directions that provide 150
0
of lateral airflow for greater conditioned air circulation
-- -----_ ~~ iii
~~---- 150
0
Multiple Filters for Cleaner Healthier Ai r Mitsubishi Electric indoor units use a sophisticated multi-part filter system to remove contaminants such as allergens viruses and bacteria from the air
A hybrid catechin pre-filter absorbs odorshycausing gases The hybrid-coating process makes the catechin filter washable and - if properly maintained with regular cleaningshyremains effective for up to 10 years
A Blue-enzyme anti-allergen filter reduces germs bacteria and viruses and helps trap dust pollens mites and other particles The filter uses an enzyme catalyst to help break down the sulfur atom bonds in allergen proteins transforming them into non-allergen proteins and effectively cleaning the air The filter should be cleaned regularly to maintain efficiency
STANDARD FILTER SYSTEM (USED IN MSYMSZmiddotGElFE18GND MODELS)
Front Panel - shy
Blue Enzyme anti-allergen filter
ENHANCED FILTER SYSTEM (USED IN MSZmiddotFE0912NA MODELS)
Programmable Comfort Smart Set featured on MSZ-GE systems provides the option to program multiple settings into one quick-press feature providing an additional level of comfort control
The POWERFUL mode (found on select systems) is available to cool or heat any desired space quickly by lowering the set temperature in cooling mode or raising the set temperature in heating mode both by T F In POWERFUL Mode the fan speed increases for 15 minshyutes then the system resumes all standard operations
Vl l
OQ
([) I
N o l ([)
Vl lt(n r-+ ([)
3 o lt ([)
s ([)
~ OJ l a --I ([) nr l o o ~
The high-efficiency MSZ-FE0912NA indoor units incorporate the standard Catechin filter plus two more filters for triple filtration The second filter a Blueshyenzyme filter made of a fibrous material renders allergens harmless by using enzymes The third filter a Platinum Catalyst Deodorizing filter has a ceramic surface absorption element and uses nanotechnology for high-power odor absorption Periodic cleaning following the recommended procedures will maintain filter effectiveness for up to two years This combination of filters provides a complete air-purifying system within the ultimate comfort solution
Front Panel - shy
Hybrid Catechin pre-filters
cJ shy Blue Enzyme anti-allergen filter
I
MITSUBISHI ELECTRIC 7
---- -- -- -
System Lineup RESIDENTIAL AND LIGHT COMMERCIAL SYSTEM MODELS AND CONTROLLERS
SINGLE
MSMU Air Conditioners
9500 to 12000 Btuh 13 SEER
bull Provides cooling-only system bull Non-INVERTER rotary compressor bull Ideal for spaces such as
bedrooms garages out-buildings video monitoring
- ROOM WALL-MOUNTED Ale (cooling only)
MSYMUY Air Conditioners
3800 to 34600 Btuh Capacity Range 151 - 21 SEER
~ -
bull Cooling-only system bull INVERTER-driven compressor bull WIDE VANE for a wider angle of airflow 150
0
from left to right (on GE24D30D36 models)
bull Ideal for spaces such as bedrooms garages large open rooms and bonus rooms
SINGLE-ROOM WALL-MOUNTED HEAT PUMPS (coo lin g and heatin g)
MSZMUZ Heat Pumps
3800 to 33200 Btuh Capacity Range
145 - 21 SEER 82 - 10 HSPF
bull Uses INVERTER-driven compressor bull Provides cooling and heating in a wide range
of capacities bull Offers a WIDE VANE for a wider angle of airflow 1500 from
left to right (on GE24D30D36 models) bull Ideal for applications in bedrooms home offices living
rooms dining rooms bonus rooms basements kitchens guard houses and more
Up to 26 SEER
MSZMUZ-FE0912NA High - Efficiency Heat Pumps
2800 to 25200 BtuH capacity range 202 - 26 SEER
10 - 106 HSPF
bull INVERTER-driven compressor bull Quiet operation as low as 19dB(A) bull i-seetrade Sensor technology bull Enhanced filtration system bull H2ireg high~heat capabilities (see page 12 amp13)
MSZ-FE09 is 100 percent at 50 F MSZ -FE12 is 92 percent at 50 F MSZ-FE18 is 100 percent at 50 F
SI NGLE-ROOM LOW WALL or FLOOR-STANDING UNIT (fo r use with MXZ -8)
New to our lineup is a Low Wall or Floor-Standing model that can fit into those once difficult installations
MFZ These units provide comfort in spaces such as (For use with MXZ-8 finished attics with knee walls basements with Outdoor Units only) low ceilings and glass-walled sunrooms
bull Provides cooling and heating in Mounted three inches above floor level these models a wide range of capacities provide conditioned air two vents and provide direct
bull Two outlet air vents front-panel access to the filter for easy cleaning The - Upper vent for cooling or heating MFZ can even be recessed in a wall during installation - Bottom vent for heating only provided proper clearances are maintained (Currently there is
bull Flush or recessed installation no 1 1 system with M FZ)
8 MITSUBISHI ELECTRIC
SING LE -ROOM HORIZONTAL- DUCTED HEAT PUMPS (coo lin g and heat ing)
WIR ELESS and W IR ED REMOTE C O NTRO LLERS
PAR-21 MAA Wireless remote controller Set Temperature
for wall-mounted and floor-standing indoor units ----- OnOff
Timer Menu Fan Speed
Fan Speed Filter
Test Run Set Time
CheckEcono Cool
Airflow UpDown Timer OnOff
Louver
Ventilation
Reset ---- shy Optional wired controller for the SEZ SLZ and MFZ indoor units (Optional controller for wall-mounted is
available and floor-standing indoor units Unit requires MAC-397 If adapter)
MHK1 WIRELESS REMOTE CONTROLLER Exclusive for INVERTER-driven Mr Slimreg Systems
Wireless Technology a SEZ and SLZ 11 systems with SUZ outdoor unit only
MIFH1
MITSUBISHI ELECTRIC 9
AMITSUBISHI ELECTRIC
l~ 1000
~r t ~~~O
MRCH1
rtj n-shy --1r-a-1-shy
Mode ------ -- shy
SEZSUZ If your customer is looking for discrete zoned comfort then a short-run ducted unit Heat Pumps is the right solution As a stand-alone system or connected to a MXZ multi-room
3800 to 19000 BtuH system the SEZ ducted units provide energy efficiency quiet operation and a Capacity Range compact design for quick easy instqllation hidden either in the ceiling or beneath
15 SEER _---~~mm the floor 175 - 10 HSPF
J ~ All of the 11 systems are ENERGY STAR certified and two systems qualify for
~ the federal tax credit These systems provide customers with an environmentally friendly indoor unit with a similar installation and familiar style
These SEZ indoor units also connect to MXZ multi-zone systems providing a wide array of installation options to best fit any application
SING LE -R OO M C EI LING -REC ESSED CASSETTE UN IT
SLZSUZ Heat Pumps The SLZ -KA ceiling-recessed units casette offer a wide
3100 to 22200 BtuH air-flow pattern for better air distribution in a less obtrusive Capacity Range style These indoor units can be used in 11 heat pump
15 - 16 SEER and multi-zone systems providing more options to your customers Install SLZs in a hard ceiling (with a access panel for
bull 96 HSPF
servicing) or in a 2x2 extra space drop ceiling With a built-in drainshylift mechanism for condensate removal and a 4 ventilation-air intake knockout option and multiple options for the 11 systems the SLZ
~ ~ handles a variety of installation needs
Two of the three 11 systems are ENERGY STAR qualified
Vl l
OQ
(I) I
N o l (I)
Vl ltV (I)
3 Vl r o ~ n OJ V (I)
1shy(MS-A12WA MODEL SHOWN)
MS COOLING-ONLY
IJON-INVERTER
Model Name Indoor Unit
Outdoor Unit
MS-A09WA MS-A12WA
MU-A09WA MU-A12WA
Cooling 1
Rated Capacity Btuh 9500 12000
Capacity Range Btuh
Total Input W 870 1070
Energy Efficiency SEER 13
Moisture Removal Pintsh 27 32 Sensible Heat Factor 068 070
Power Supply Phase Cycle Voltage 1 Phase 60Hz 115V 2
Voltage Indoor - Outdoor L1-N AC 115V Indoor - Outdoor N-2 AC 115V Indoor - Remote Controller Wireless Type
Indoor Unit
MCA A 12
Fan Motor FLA 095
Airilow (Lo-Med-Hi Poweriul)
DRY (CFM) 183-261-335-367 222-286-406-446
WET (CFM) 162-233-300-328 198-254-363-399
Sound Pressure Level (Lo-Med-Hi)
dB(A) 26-32-40-42 33-38-45
External Finish Color Munsell No 1OY 9202
Dimension Unit
W In 30-1116
0 In 8-14
H In 11-34
Weight Unit Lbs 23
Field Drainpipe Size 00 In 58
Outdoor Unit
MCA A 14 16
MOCP (Time Delay) A 15 20
Fan Motor FLA 063 093
Compressor
Model (Type) Single Rotary
RLA 93 1082
LRA 47 56
Airilow CFM 1083 1327
Refrigerant Control Capillary Tube
Sound Pressure Level (Cooling) 1
dB(A) 47 52
External Finish Color Munsell No 3Y 7811
Dimensions
W In 31-12 33-716
0 In 11-14 11-716
H In 21-58 23-1316
Weight Lbs 78 96
Remote Controller Type Wireless Remote
Refrigerant
Type R410A Charge Lbs Oz 25 31
Oil Type (FI Oz) NE022 (108)
Refrigerant Pipe
Gas Side 00 In 38 12
Liquid Side 00 14
Height Difference (Max) Ft 35
Length (Max) 65
Connection Method IndoorOutdoor FlaredFlared
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling) - Indoor DB 800 F(270 e) WB 670 F(190 e) Outdoor DB 950 F(350 e) WB 750 F(240 e) 2 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice
LlIVIITED WARRANTY ISeven-year warranty on compressor Five-year warranty on parts
10 MITSUBISHI ELECTRIC
I
R ---I Vl
J(MSY-GE1 7NA MODEL SHOWN) OQ
MSY COOLI NG-ON LY (CO NT ) CD N o J CD
s Vl OJ J
Cooling 1 0shy
s Vl -lt Vl
~~~~~-=~------~~--------------------------~~~~----------------------------~ jVoltage
205-272-335shy145-170-237 -321-399
420-533 170-237 -300shy
385-498
26-32-38-44-49Indoor Unit
Outdoor Unit
194-240-304shy385-498
28-33-38-44-49
388-469-628-738
347-420-562-661
34-41-49-53
CD n 3-i n OJ 0389-639-848 o J350-576-763 V)
32-42-49
2 9 43Refrigerant
FV50S (040) NE022 (295)
Refrigerant Pipe
Refrigerant Pipe Length
Connection IndoorOutdoor FlaredFlared
Method
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling) - Indoor DB 80deg F(27deg e) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice
LIMITED WARRANTY ISeven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 11
~ (MSZ-FE12NA MODEL SHOWN)
MSZ HEAT PUMP TAX
CREDIT
Model Name
Cooling 1
Indoor Unit Outdoor Unit
Rated Capacity Btuh
MSZ-GE09NA MUZ-GE09NA
9000
MSZ-FE09NA HshyMUZ-FE09NA bull
9000
MSZ-GE12NA MUZ-GE12NA
12000
MSZ-FE12NA MUZ-FE12NA
12000
H-bull MSZ-G MUZ-G
14000
Capacity Range Btuh 3800-12200 2800-9000 3800-13600 2800-12000 3100-18200
Total Input W 660 (205-1200) 580 (160-650) 960 (205-1300) 930 (160-960) 1080 (160-2000)
Energy Efficiency SEER 21 26 205 23 21
Moisture Removal Pintsh 15 21 25 29 27
Sensible Heat Factor 082 076 074 073 080
Heating at 47deg F 2
Rated Capacity Btuh 10900 10900 14400 13600 18000
Capacity Range Btuh 4500-14100 3000-18000 5500-18100 3000-21000 4800-20900
Total Input W 760 (255-1200) 710 (150-2250) 1170 (340-1660) 950 (150-2250) 1600 (270-2010) HSPF (IV) BtuhlW 10 106 10
Heating at 17deg F3 Rated Capacity Btuh 6600 6700 8800 8300 11300 Rated Total Input W 700 650 900 800 1150 Maximum Capacity Btuh 8700 12500 11200 13600 15900
Heating at 5deg F Maximum Capacity Btuh 7061 10900 9194 12500 13022
Power Supply Phase Cycle Voltage 1-phase 60Hz 208 230V 4
Voltage
Indoor - Outdoor S1 - S2 AC 208 230V
Indoor - Outdoor S2 - S3 DC12-24V
Indoor - Remote Controller Wireless Type (Optional Wired Controller DC 12V)
Indoor Unit
MCA A 10
Fan Motor FLA 076
Airflow at Cooling (Lo-Med-Hi-Super HI-Powerful) 1
DRY (CFM) 145-170-237-321-399 162-226-339-381 145-170-237-321-399 162-226-381-410 205-272-335-420-533
WET (CFM) 109-134-201-286-364 144-202-307-343 109-134-201-286-364 144-202-350-367 170-237-300-385-498
Airflow at Heating (Lo-Med-Hi-Super HI-Powerful) 2
WET (CFM) 145-170-237-321-406 166-240-367-381 145-170-237-321-406 166-240-399-420 205-247 -304-367-463
Sound Pressure Level at Cooling (Lo-Med-Hi-Super HI-Powerful) 1
dB(A) 19-22-30-37-43 22-31-39-42 19-22-30-37-45 22-33-43-45 26-32-38-44-49
Sound Pressure Level at Heating (Lo-Med-Hi-Super HI-Powerful) 2
dB(A) 19-22-30-37-43 22-31-40-42 19-22-30-37-43 22-33-43-44 26-30-35-40-46
External Finish Color Munsell No 10Y 92 I 02
Dimension Unit
Wln 31-716 31-38 31-716 31-38 31-716
0 In 9-118 10-18 9-18 10-18 9-18
H In 11-58
Weight Unit Lbs 22 27 22 27 22
Field Drainpipe Size 00 In 58
Outdoor Unit
MCA A 12
MOCP A 15
Fan Motor FLA 050 056 050 056 050
Compressor
lVIodel (Type) DC INVERTER-driven DC INVERTER-driven Twin
Rotary DC INVERTER-driven DC IIWERTER-driven Twin Rotary
RLA 66 86 66 86 74
LRA 82 108 82 108 93
Airflow (CoolingHeating) CFM 11511225 1102 11187 12291172 1102 11187 12431229 Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(A) 46 48 49 48 49
Sound Pressure Level at Heating 2 dB(A) 50 49 51 49 51
External Finish Color Munsell No 3Y 78 11
Dimensions
Wln 31-12
0 In 11-114
H In 21-58
Weight Lbs 66 80 77 80
Remote Controller Type Wireless Remote (Optional Wired Controller)
Refrigerant
Type R410A
Charge Lbs Oz 112 29
Oil Type (fl oz) NE022 (108) NE022 (152)
Refrigerant Pipe Gas Side 00 In 38 12
Liquid Side 00 In 14 14
Refrigerant Pipe Length Height Difference (Max) Ft 40
Length (Max) Ft 65 I
Connection Method IndoorOutdoor FlaredFlared
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg e) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg e) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg e) Outdoor DB 47deg F(8deg e) WB 43deg F(6deg e) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg e) Outdoor DB 17deg F(-8deg e) WB 15deg F(-9deg e) 4 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice
12 +MITSUBISHI ELECTRIC LIMITED WARRANTY ISeven-year warranty on compressor Five-year warranty on parts
- shy(MSY(Z)-D30NA MODEL SHOWN)
Vl J
09 (I)
I
N o J (I)
s Vl N Vl
-0 (I) n 31 n OJ 0 o J V)
Model Name Indoor Unit MSZ-GE18NA MSZ-FE18N MSZ-GE24NA MSZ-D30NA MSZ-D36NA
Outdoor Unit MUZ-GE18NA MUZ-FE18rK MUZ-GE24NA MUZ-D30NA MUZ-D36NA Rated Capacity Btuh 17200 18000 22500 30700 33200
Capacity Range Btuh 3700-18700 8200-25200 8200-31400 9800-30700 9800-33200
Total Input W 1640 (240-2070) 1270 (570-2280) 1800 (570- 3580) 3850 (620-3850) 4360 (620-4360) Cooling 1
Energy Efficiency SEER 192 202 190 145
Moisture Removal Pintsh 46 27 27 99 11 3
Sensible Heat Factor 071 084 075 064 062
Rated Capacity Btuh 21600 21600 27600 32600 35200
Capacity Range Btuh 3500-25200 7500-29700 7500-36900 8700-34000 8700-36000 Heating at 47deg F 2
Total Input W 1900 (230-2680) 1540 (520-2240) 2340 (520- 3650) 3360 (520-3600) 3840 (520-4100)
HSPF (Region IV) BtuhIW 10 103 10 82
Rated Capacity Btuh 13400 11700 16000 19500 21800
Heating at 17deg F 3 Total Input W 1450 2180 3290 2400 2820
Maximum Capacity Btuh 17200 19300 24600 20800 22800 Heating at 5deg F
Maximum Capacity Btuh 13562 21 600 21160 16305 19090
Power Supply Phase Cycle Voltage 1 Phase 60Hz 208230V 4
Indoor - Outdoor S1-S2 AC 208 230V Voltage Indoor - Outdoor S2-S3 DC12-24
Indoor - Remote Controller Wireless Type (Optional Wired Controller DC12V) MCA A 10 Fan Motor FLA 076
DRY (CFM) 230-275-339-420-533 388-469-628-738 388-469-628-738 389-639-848 Airilow (Cool) (Lo-Med-Hi-Super HI-Poweriul) 1
WET (CFM) 194-240-304-385-498 347-420-562-661 347-420-562-661 350-576-763
Airilow (Heat) (Lo-Med-Hi-Super HI-Poweriul) 2 DRY (CFM) 230-275-339-431-512 388-469-628-738 388-469-628-738 445-639-848
Sound Pressure Level (Cooling) (Lo-Med-Hi-Super 28-33-38-44-49 34-41-49-53 34-41-49-53 32-42-49
HI-Poweriul) 1
Sound Pressure Level (Heating) (Lo-Med-Hi-Super dB(A)
Indoor Unit 28-33-38-43-48 32-41-49-52 32-41-49-52 34-42-49-49HI-Poweriul) 2
External Finish Color Munsell No 1 OY 9202
W In 31-716 43-516 46-116
Dimension Unit D In 9-18 9-38 11-58
H In 11-5 8 12-1316 14-38
Weight Unit Lbs 22 37 40
Field Drainpipe Size OD In 58
MCA A 14 171 21
MOCP A 15 20 25
Fan Motor FLA 093
Model (Type) DC INVERTER-driven Twin Rotary
Compressor RLA 100 129 16
LRA 125 161 20
Airilow CFM 1730 1659 17691 701 1941
Outdoor Unit Refrigerant Control Linear Ex~ansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(A) 54 55 56
Sound Pressure Level at Heating 2 dB(A) 56 55 57
External Finish Color Munsell No 3Y 7811
W In 33-116
Dimensions D In 13
H In 33-716 34-58 33-716
Weight Lbs 119 141
Remote Controller Type Wireless Remote (Optional Wired Controller)
Type R410A
Refrigerant Charge Lbs Oz 3 7 43 410
Oil Type (FI Oz) NE022 (152) FV50S (135) NE022 (29)
Gas Side OD 12 58In
Refrigerant Pipe Liquid Side OD 14 38
Height Difference (Max) 50
Length (Max) Ft
100 I Connection
Mpthon IndoorOutdoor Flared Flared
NOTESTest conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg C) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F (24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F(6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 17deg F(-8deg C) WB 15deg F(-9deg C) 4 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice LIMITED WARRANTY ISeven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 13
(SEZ-KD12NA MODEL SHOWN)
SEZ HEAT PUMP TAX
CREDIT
Model Name Indoor Unit SEZ-KD09NA4 SEZ-KD12NA4 SEZ-KD15NA4 SEZ-KD18NA4
Outdoor Unit SUZ-KA09NA SUZ-KA12NA SUZ-KA15NA SUZ-KA18NA Rated Capacity Btuh 8100 11500 14100 17200
Capacity Range Btuh 3800-10900 3800-13300 3800-17000 3800-19000
Cooling 1 Total Input W 670 920 1170 1380
Energy Efficiency SEER 15 16 155 175 Moisture Removal Pintsh 15 24 26 34 Sensible Heat Factor 080 076 080 079
Rated Capacity Btuh 10900 13600 18000 21600
Heating at 4YO F 2 Capacity Range Btuh 4800-14100 4800-16400 4800-21100 4800-24900
Total Input W 1020 1140 1500 1700 HSPF(lV) BtuhIW 100 Rated Capacity Btuh 6700 9000 11900 13100
Heating at 1 yo F 3 Rated Total Input W 810 920 1200 1350 Maximum Capacity Btuh 7300 9800 13700 15000
Power Supply Phase Cycle Voltage 1 Phase 60Hz 208 230V 4 Indoor - Outdoor S1 - S2 AC 208-230V
Voltage Indoor - Outdoor S2 - S3 DC 12-24V Indoor - Remote Controller See optional accessories chart (pg 26 and 27) MCA A 1 Fan Motor FLA 051 057 074
Airflow (Lo-Med-Hi) DRY (CFM) 194-247-317 247-317-388 353-441-529 423-529-635
WET (CFM) 174-222-285 222-285-349 317 -396-4 76 381-476-572 External Static Pressure 3 In wG 002-006-014-020 Sound Pressure Level dB(A) 23-26-30 23-28-33 30-34-37 30-34-38
Indoor Unit External Finish Galvanized-Steel Sheets
W In 31-18 39 46-78
Dimension Unit D In 27-916
H In 7-78
Weight Unit Lbs 42 50 54 62 Field Drainpipe Size 00 In 1-14
MCA A 12 14
MOCP A 15 Fan Motor FLA 050 093
Model DC Inverter DC Inverter Twin Rotary
I (Type)Compressor
RLA 66 74 10
LRA 82 93 125
Airflow (CoolingHeating) CFM 11511225 12291172 1 2431 229 17301659
Outdoor Unit Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(A) 46 49 54 Sound Pressure Level at Heating 2 dB(A) 50 51 56
External Finish Color Munsell No 3Y 7811
W In 31-12 33-16
Dimensions D In 11-14 13
H In 21-58 33-716
Weight Lbs 66 77 80 119 Remote Controller Type See optional accessories chart (pg 26 and 27)
Type R410A
Refrigerant Charge Lbs Oz 116 2 9
Type (fl Oil
oz) NE022 (108)
Refrigerant Pipe Gas Side OD In 38 Liquid Side 00 In 14
Refrigerant Pipe Height Difference (Max) Ft 40 Length Length (Max) Ft 65
Connection IndoorOutdoor FlaredFlared
Method
316
NE022 (152)
12
50
100
I
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg C) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F(8deg C) WB 43deg F(6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 17deg F(-8deg C) WB 15deg F(-9deg C) 4 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
14 MITSUBISHI ELECTRIC
SEZ STATIC PERFORMANCE CURVES (SEZ-KD12NA4 MODEL SHOWN)
SEZ-KD09NA4 SEZ-KD09NA4 (External static pressure O06[inwG]) 208230V 60Hz
[020] V L
5 [016
~l [0 12
]
SEZ-KD09NA4
~ ltij
~ [008
Jj
]
]
[004J ~
V V Middle
Low
V
19h
Rated point
1
o [141] [176J 1212) )247] [282J [318]
Airll ow rat e [CFM)
SEZ-KD12NA4 (External static pressure O06[inwG]) 208230V 60Hz
[020
5 [016
]
]
[353J
Limit
]
~ V
~ [ [0 12
u ltijJ[008
[004
]
_V ]~ Low
V
k-iddle
Rated POint
o [212) [247] [2 82] [318] [353] [388]
Airtlow rate [C FM]
SEZ-KD1SNA4 (External static pressure O06[inwGl) 208230V 60Hz
[424)
1020]
5 [016
~ ~ [012
~ ltij
~ [008
Jj
J
)
]
[004 ]
o
VV V [ Low
VV
vV High
Middle
I Rated point
[282] [318) [353] [388] [424] [459] [494] [530] [565J
Airllow rat e [CFM]
SEZ-KD18NA4 (External static pressure O06[inwG]) 208230V 60Hz
50 10 20]
] 40
5 [016
s 30 [ (012 )
ltij 20 ~ [008 )~Jj
10 [004]
V
Low
v Limit
rIV High
V [ Middle
~
1
Rated point
f318) [353) [388] [424] [459] [494] [530] [565] [600] [636] [671 )
Airllow rate [CFM]
(External static pressure O14[inwG]) 208230V 60Hz 80
[0 32
70 [028
5 60 [024
20 [0 08
10 [004
]
]
J
]
]
J
]V
]
U~it
V
k
High
~V Rated POI~1 V Middle Low
~
o [141] [1 76] 12121 )247J [282] [318]
Airtlow rate [CFM)
SEZ-KD12NA4 (External stat ic pressure O14[inwG]) 208230V 60Hz
[032]
[028J
5
[353]
J
~ [024
-~ [020] V-is
J V Il Hi9h Rated point
[016
~ ]
V V1 Middle
~ [012
[008]~
[004)
o [212)
[247)
SEZ-KD1SNA4
Low r
[282] [31 8) [353]
Airllow rale [CFM]
[388]
(External static pressure O14(inwG]) 208230V 60Hz
[032J
[424
]
2 V[028
5 [024]
V-i
] V High i [020
] K
Middle Rated point [0 16
g ]
~ -
QJj [0 12
J Low
[008
] I
~
[004
o [282J [318) [353J [388J [424) [459] [4 94] [530) [565)
Airt low rate [CFM]
SEZ-KD18NA4 (External statiC pressure O14(inwG]) 208230V 60Hz
1032
1028
~ 1024
-~ [0 20
is (0 16 ltij E ~ [012
(008
(004
o
I
]
]
)
]
)vlt ]
]
~ V
VV
Low
Limit
V
Ji9h
Middle l
Rated point
1 t
1
~ [318] [353] [388] [424] [459) [4 94] [530) [565) [600] [636] [671)
Airllow rate [CFM]
(External static pressure O20(inwG]) 208230V 60Hz
[032 ]
[028 J
5 [024
~ [020
is [016
1 [012Jj
[008
[004
J
]
]
] )
]
V Low
umz V High
~V
Rated point
Middle
1
[141] [176] [212) [247) [282) [318) [353J
Airtlow rat e [CFM]
SEZ-KD12NA4 (External static pressure O20(inwG]) 208230V 60H z
[032 ] LLimit
)
[0 28
5 ]
V
[024 -~ [020] V Rated point
Highis ~
) V
bull Middle
]~V I
[016
~ ~ [012
] Low
[008
]
[0 04
o [212) [247] [282] [318] [353] [388] [424]
Airllow rate [CFM]
SEZ-KD1SNA4 (External static pressure O20(inwG]) 208230V 60Hz
80 [032 ]
70 [0 28
~ [ O~~ -
ltij
E 30 ~ [0 12
20 [008
10 [004
o
)
J
]
]
JV
J
J
Limit V
LV High
V ~
K Rated point
Middle
VV 1gt
Low
I-
~ [282) [318) (353] (388) (424) 1459] [494] 15301 [565)
Airtlow rate [CFM]
SEZ-KD18NA4 (External static pressure O20[inwG]) 208230V 60Hz
[032
[028
~ [024sect
I [020
~ [016
~ Jj [0 12
[008
[004
o
]
)
]
]
]
~ )
]
]
1V
V 1
V
Low
1 limit
~~~ I ~~ High
~ R~ted pOini
Middle
1 1 -
[31 8) [353] [388] [424) [459] [494] [530] (565) [600] (636) [671J
Airllow rate [CFM)
Vl ~ ca (I)
I
N o ~ (I)
Vl m N Vl
-0 (I) n 3-i n QJ ~ o ~ tn
Note ESP 20S230V 60 Hz See manual for Static Performance Curve including 002 in WG
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts ~MITSUBISH[ ELECTRIC 15
SLZ HEAT PUMP (SLZ-KA12NA MODEL SHOWN)
Model Name Indoor Unit SLZ-KA09NA SLZ-KA12NA SLZ-KA15NA
Outdoor Unit SUZ-KA09NA SUZ-KA12NA SUZ-KA15NA Rated Capacity Btuh 8400 11100 15000
Capacity Range Btuh 3100-10900 3100-13300 3100-22200
Cooling 1 Total Input W 700 920 1460
Energy Efficiency SEER 15 154 16 Moisture Removal Pintsh 12 23 45 Sensible Heat Factor 080 076 080
Rated Capacity Btuh 10900 13 600 18000
Heating at 4r F 2 Capacity Range Btuh 3100-14100 3100-17100 3100-17100 Total Input W 930 1180 1950 HSPF (IV) BtuhIW 96 Rated Capacity Btuh 6200 8300 10200
Heating at 17deg F 3 Rated Total Input W 740 930 1310 Maximum Capacity Btuh 8300 10200 12000
Power Supply Phase Cycle Voltage 1 Phase 60Hz 208 230V 4 Indoor - Outdoor S1 - S2 AC 208-230V
Voltage Indoor - Outdoor S2 - S3 DC 12-24V
Indoor - Remote Controller See optional accessories chart (pg 26 and 27) MCA A 1 Fan Motor FLA 023 028 028
Airflow (Lo-Med-Hi) DRY (CFM) 280-320-350 280-320-390 280-320-390
WET (CFM) 250-290-320 250-290-350 250-290-350
Sound Pressure Level dB(Al 29-32-38 30-34-39 31-35-40
Indoor Unit External Finish Galvanized-Steel Sheets Grille Munsell 64Y 8904
W In 22-7 16 (25-58)
Dimension Unit (Grille) D In 22-716 (25-58
H In 8-316 (1316)
Weight Unit (Grille) Lbs 36 (7) Field Drainpipe Size 0 0 In 1-14 MCA A 12 MOCP A 15 Fan Motor FLA 050
Model (Type) DC INVERTER-driven DC INVERTER-driven
Compressor RLA 66
LRA 82
Airflow (CoolingHeating) CFM 11511225 1 229 1 172
Outdoor Unit Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(AJ 46 49 Sound Pressure Level at Heating 2 dB(AJ 50 51
External Finish Color Munsell No 3Y 781 1
W In 31 shy12
Dimensions 0 In 11-14
H In 21-58
Weight Lbs 66 77
~e R410A
Refrigerant Charge Lbs Oz 1 16
Oil Type (fl oz) NE022 108)
Refrigerant Pipe Gas Side 0 0 In 38 Liquid Side 00 In 14
Height Difference (Max) Ft 40 Refrigerant Pipe Length
Length (Max) Ft 65
Connection Method IndoorOutdoor FlaredFlared
29
Twin Rotary 74
93
12431 229
80
NE022 l152) 12
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg C) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F(8deg C) WB 43deg F(6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 17deg F(-8deg C) WB 15deg F(-9deg C) 4 Indoor units receive power from outdoor units through field-supplied interconnectedwiring Specifications are subject to change without notice
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
16 MITSUBISHI ELECTRIC
MHK1 WIRELESS REMOTE CONTROLLER KIT Exclusive for INVERTER-driven Mr Slimreg Systems VlWireless Technology a J
JMITSUBISHI ELECTRIC
Wireless Receiver
MHK1 Kit includes
09 mMRCH1 WIRELESS REMOTE CONTROLLER I Nbull Backlit easy-to-read display o
bull Dual setpoint control with system changeover J m
bull Enabled with RedLlNKTM reliability
bull Compatible with MCCH1 Vl Portable Central Controller m
N bull Installs Anywhere Vl
MFH1 WIRELESS RECEIVER N Vlbull Required for MRCH1 Wireless
CRemote Controller m bull Enabled with RedLiNK reliability n
31 n OJ o J en
SEZ and SLZ 11 systems with SUZ outdoor unit
Function Description
ONOFF OnOff operation for a single indoor unit
Operation Mode Cool I Drying I Auto I Heat I Fan only Available operation modes dependant on connected system
Temperature Setting Set temperature from 50degF - 8rF depending on operation mode and connected system
System Changeover Deadband Value 2-8degF
Schedule Operation 5-25-1-1
Fan Speed Setting HiMid-2Mid-1 IlowlAuto Available fan speed settings dependant on connected system
Air Flow Direction Setting Air flow angles 100deg - 80deg - 60deg - 40deg and oscilate Available air flow direction settings dependant on connected system
PermitProhibit Function Individual prohibit operations for each remote controller function (ONI OFF Set Temperature and Operation Mode)
Space Temperature Displays the measured space temperature
Error Indication Displays error code
Display Outside Temperature and Humidity
Requires optional MOS1 Outside Air Sensor
Dimensions - ryv x D x H) Remote Controller 5-316 x 1-12 x 3-916 Receiver 3-14 x 1-516 x 6-716
Operating Ambient Temperature Remote Controller 32 - 120degF Receiver -40 - 165degF
Operating Ambient Humidity Remote Controller 5 - 90 RH (non-condensing) Receiver 5 - 90 RH (non-condensing)
Power Supply 2 AA batteries
MRCH1 MIFH1 MRC1
Wireless Wall-Mounted Remote Controllers Wireless Receiver Cable
Accessories MCCH1 MOS1
Portable Central Controllers Outside Air Sensor
MITSUBISHI ELECTRIC 17
MULTIPLE ROOMS WITH INDIVIDUAL CONTROL FROM A SINGLE SYSTEM Enjoy ideal levels of comfort in the rooms you use most with our multi-room system Each room (zone) operates independently People in different rooms - the kitchen master bedroom or living room - can enjoy temperature settings that make each of them most comfortable
If you re looking for a complete comfort solution for several different rooms the MXZ multi-room system is the right choice The system is flexible enough to conform to a particular cooling and heating need and offers numerous different indoor unit combinations In addition up to eight indoor units can be connected to one outdoor unit Now with a SEZ horizontal ducted unit and a MFZ floorshystanding unit homeowners can enjoy an even greater range of zoning options provided by an MXZ system
An MXZ multi-room system is an excellent choice for supplementing capacity to a current system conditioning newly furnished spaces or new additions and replacing a system within a home Homeowners can also benefit from lower energy costs year-round while staying comfortable thanks to Mitsubishi Electrics energy-efficient technologies that are a part of every system that we make
To add to the level of energy efficiency the MXZ -2B20NA and MXZ -3B24NA systems qualify for both ENERGY STARreg and the federal tax credit (See details on page 21 for applicable indoor unit combinations)
At right a single level home with several system types represented (For illustrative purposes only)
MFZ Floor-Standing Indoor Units for MXZ Heat Pump Systems
Floor-standing indoor unit mounts three inches above the floor and has front panel access to the filter for ease of cleaning
The MFZ units provide energy-efficient solutions to provide personalized comfort for difficult areas that may be smaller or dont have usable space on the walls
MFZ units on MXZ systems include the following features bull Top and bottom discharge vanes bull Hot-start technology bull Quiet operation bull Wireless remote control (optional wall-mounted controller)
18 MITSUBISHI ELECTRIC
MSZ Wall-Mounted Indoor Units for MXZ Heat Pump Systems
Providing a wide range of cooling and heating capacities each wall-mounted indoor unit mounts high on a wall and connects to a branch box or the outdoor unit by a refrigerant line run via a 3 hole The MSZ units provide highly efficient solutions to cooling and heating needs and provide personalized comfort for the individual zones in which they are installed
MSZ units on MXZ systems include the following features bull Sleek flat panel design bull Hot-start technology bull Quiet operation bull i-seeM sensor technology (MSZ-FE0912NA models only) bull Enhanced filtration system (MSZ-FE0912NA models only) bull Wireless remote control (optional wired wall-mounted controller)
SLZ Ceiling-Recessed Indoor Units for MXZ Heat Pump Systems
The new SLZ-KA ceiling casette systems offer a wide air-flow pattern for better air distribution
offered to your customers Installation can be done in a hard ceiling (with a access panel for servicing) or placed into a 2x2 drop ceiling With a built-in drain lift mechanism for condensate
removal and a 4 ventilation air intake knockout option the SLZ is ready to handle a variety of installation needs
SLZ units on MXZ systems include the following features bull Wide air-flow pattern for better air distibution bull 4 ventillation air intake knockout bull Built-in condensate lift mechanism bull Wireless RedLlNKTM remote controller
SEZ Horizontal Ducted Indoor Units for MXZ Heat Pump Systems
SEZ ducted units can provide split air-conditioning system advantages with the added benefit of being concealed to provide virtually no visual footprint within the conditioned space other than a register and grille for the air to flow With the use of short run ductwork these units can provide comfort to a single room that needs air dispersed evenly throughout the space unusually shaped rooms and adjacent rooms
The SEZ unit on MXZ systems include the fOllvowin fatures _
g~e~~~~==Zl[bull Concealed design for short-run ductwork bull Quiet operation bull Built-in condensate lift mechanism
JMITSUBISHI ELECTRIC 19
s c t
I
N o J ro o ltro ~ ro ~
DIAMOND COMFORT MXZ MULTI-ZONE SYSTEMS MXZ-B Series multi-zone systems provide personalized comfort control and energy efficiency in up to eight rooms with only a single outdoor unit The MXZ-B Series system features include
bull Individual zone control bull Mix and match flexibility of indoor unit styles and combinations bull A wide range of indoor unit capacities that match the room size and requirements bull Flexible design options to tackle the most challenging multi-room installations bull Efficient systems including three systems [mxz series] that meet energy starltID and
federal tax credit requirements bull Simple quick and cost-effective installation keeps install costs down on new construction
and disruption to a minimum on renovations and refits
Efficiency and performance ratings depend on the number style and capacity of the indoor units installed with each Multi-Zone System
MXZ -2 B20 NA - 1 (2 1 ) MXZ -3 B24 NA (2 13 1) Ou tdoo r Unit Outdoor Uni t
MSZ-GE09NA Indoor Units
SEZ-KD12NA Indoor Unit
MSZ- GE06NA
~~~~li
(At least two indoor units MSZ-GE06NAIndoor Unit must be installed) Indoor Unit
(Two indoor units must be installed )
MXZ -3 B30 NA (2 1 3 1) Outdoor Unit
SEZ-KD12NA Indoor Unit
~~~i
(At least two indoor units MSZ-GE06NA must be installed)
Indoor Unit ~
MFZ- KD12NA Indoor Unit
MXZ-8B48NA (2 1-8 1) Outdoor Unit
(At least two indoor units
must be installed)
(At least two indoor units must be installed)
MFZ-KD09NA Indoor Units
MSZ-GE09NA Indoor Units
SEZ-KD12NA Indoor Unit
MSZ INDOOR UNIT
MSZ-FE18NA
PEAD HORIZONTAL -DUCTED INDOOR UNIT
PEAD-A24AA
MSZ INDOOR UNIT SEZ HORIZONTAL-DUCTED MSZ-FE18NA
INDOOR UNIT MFZ FLOOR-STANDING SEZ-KD18NA INDOOR UNIT
MFZ-KA12NA
20 AMITSUBISHI ELECTRIC
MULTI-ROOM MXZ-8 INVERTER HEAT PUMP R
Model Name Outdoor Unit MXZ-2B20NA-1 5 MXZ-3B24NA 6 MXZ-3B30NA MXZ-4B36NA 7
Indoor Unit
Cooling 1 Non-ductedl Ducted
Rated Capacity Btuh 1800020000 2200023600 28400127400 3540034400
Capacity Range Btuh 7800-20000 12600-25500 12600-28400 12600-36400
Total Input W 2190 (630-219QL 2460 (1000-2950) 3330 l1 000-3330) 3 940 (1 000-4020)
Heating at 4JO F 2 Non-ductedl Ducted
Rated Capacity Btuh 2200022000 2500024600 2860027600 3600034400
Capacity Range Btuh 8500-25500 11400-30600 11 400-36000 11400-43000
Total Input W 2620 (520-2620) 1900 (740-2600) 2220 (740-2820) 3100 (740-3940)
Heating at 1JO F 3 Non-ductedl Ducted
Rated Capacity Btuh 1250012500 1400014000 1600015100 2220020300
Rated Total Input W 13501430 13801570 21202 140 24302340
Maximum Capacity Btu h 1450014500 1880017000 1880018000 2460025400
Maximum Total Inl2ut W 15001590 21202230 21202140 33403450
Power Supply Phase Cycle Voltage 1-phase 60Hz 2081 230V 8
Voltage Indoor shy Outdoor S1 - S2 AC 2081 230V
Indoor shy Outdoor S2 - S3 DC12-24V
Outdoor Unit 4
MCA A 15 19
MOCP A 20
Fan Motor FLA 096 093
Compressor
Model (Type)
DC INVERTER-driven Twin Rotary
RLA 101 11 144
LRA 15
Airflow (CoolingHeating) CFM 14851 640 20681605 13651605 20682068
Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1
dB(A) 49 54 49 54
Sound Pressure Level at Heating 2
dB(A) 51 49 57
External Finish Color Munsell No 30Y 781 1
Dimensions
W In 33-116 35-716
D In 13 12-58
H In 27-1516 35-7116
Weight Lbs 130 150 153
Indoor Unit No of Units 2 23 23 234
Remote Controller Type Associated with the Indoor Unit
Refrigerant
Type R410A
Charge Lbs Oz 515 7 11 813
Oil Type (fl oz)
NE022 (237) NE022 (294)
Refrigerant Pipe Gas Side 00 In AB 38 A 12 BC 38 A 12 BCD 38
Liquid Side 00 In 14
Refrigerant Pipe Length Height Difference (Max) Ft 4933 9
Length (Max) Ft 164 (A+B) 230 (A+B+C) 230 (A+B+C+D)
Connection Method IndoorOutdoor FlaredlFlared
Compatible with the MSZ-A MSZ-GA MSZ-FD MSZ-FE MSZ-GE MFZ-KA and SEZ-KD series indoor units (PLA-18 amp PCA-24 on the MXZ-MXZ-3B PLA-24 amp PCA-24 on the MXZ-4B)
NOTES Test conditions are based on AHRI 210240 One indoor unit is turned off during low-speed testing under the new test conditions Systems actually exhibit higher energy efficiencies during normal operation
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F (35deg C) WB 75deg F (24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F (6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 600 F (160 C) Outdoor DB 17deg F (_80 C) WB 150 F (_90 C) 4 Refer to pages 12 and 13 for Indoor Unit specifications 5 Data from combination of two Indoor Units 9000 Btuh (non-ducted) or one 9000 Btuh and one 12000 Btuh (ducted) 6 Data from combination of two Indoor Units 6000 Btuh and one 9000 Btuh (non-ducted) or three 9000 Btuh (ducted) 7 Data from combination of four Indoor Units 9000 Btuh (non-ducted and ducted) 8 Indoor units receive power from outdoor units through field-supplied interconnected wiring 9 49 Applies to installations where the outdoor unit is installed below the indoor unit
Power factor equals 97 percent
Specifications are subject to change without notice
MULTI-ZONE ENERGY STAR AND TAX CREDIT SYSTEMS
Model Indoor Unit Combinations SEER HSPF
MXZ-2B20NA-1 2 x MSZ- GE09NA 18 8 9
MXZ- 3B24NA 2 x MSZ- GE06NA 1 x MSZshy GE09NA
17 5 9 3
MXZ- 3B24NA 2 x MSZ-GE06NA 1 x MSZ- GE12NA
17 5 93
For more details on all ENERGY STAR and tax credit systems go to wwwmitsubishicomfortcomtaxcredit
See page 25 for additional info on efficiency
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 21
MXZ-8B48NA THE ULTIMATE ZONING SOLUTION
The Mitsubishi Electric MXZ-S84SNA eight-zone unit As a member of the expanding MXZ-B Series of multi-zone systems the MXZ-8B outdoor unit incorporates branch boxes to connect up to eight indoor units MXZ- 8 B48 NA (2 1 - 8 1 )
Outd oor Uni t The INVERTER-driven compressor at the heart of the MXZ-8B -~-- shy
outdoor unit provides variable capacity control allowing the system to adjust to the specific demands of the interior space ~ as needed not the hard start and stop of a traditional system I[iDA Jinstalled in most US homes
The MXZ -8B48NA has only one port on the outdoor unit for two insulated refrigerant lines which run into the home or business to connect to a branch box or boxes From the branch box(es) gas and liquid refrigerant piping run to each of the indoor units The LEV in the branch box(es) controls the refrigerant flow as the load of each zone changes
Through the branch box(es) (the PAC-AKA31 BC three-port andor the PAC-AKA51 BC five-port) the system can connect from two indoor units up to eight indoor units depending on application requirements
The flexibility of the system doesnt stop there The MXZ-8B48NA has rated capacities of 48000 Btuh for cooling and 54000 Btuh for heating System operation however can range from a minimum 12000 Btuh to a maximum 54000 Btuh in cooling and a maximum of 60000 Btuh in heating This type of performance supports a large variety of applications
The MXZ-8B48NA allows for further flexibility because it supports a connected indoor unit capacity from 22 to 130 or 12000 Btuh to a maximum 70200 Btuh depending on diversity
Connectable Indoor Units General Features bull Four-ton outdoor unit can support up to
eight indoor units using branch boxes bull Wide variety of indoor unit styles
-=--_-=-----= - - J _ 1
including wall-mounted floor-standing MSZ-FE09 12 18NA MSZ-GE06 09 12 15 18 24NA ceiling-cassette ducted
bull Individual control up to eight (8) zones using wired or wireless controls
bull Advanced microprocessor control bull Auto restart following a power outage bull Self-check function offering SEZ-KD09 1215 18NA PEAD-A24AA
integrated diagnostics ~--- Jbull Limited warranty five years on parts and
defects and seven years on compressors
SLZ-KA09 1215NA MFZ-KA09 12 18NA
22 MITSUBISHI ELECTRIC LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
I
RMULTI-ROOM MXZ-8 INVERTER HEAT PUMP
Model Name Outdoor Unit MXZ-BB4BNA Cooling 1 Rated Capacity
Non-ducted Rated Total Input Ducted
Maximum Capacity
Rated CapacityHeating at
Rated Total InputIndoor Unit 4JO F 2 Non-
ductedDucted Maximum Capacity
Rated Capacity Heating at
Rated Total InputlJO F 3 Non-ductedDucted Maximum Capacity
Power Supply Phase Cycle Voltage
Indoor - Outdoor Sl - S2 Voltage
Indoor - Outdoor S2 - S3
MCA
Recommended FuseBreaker Size
Fan Motor
Compressor
Airflow (CoolingHeating)
Refrigerant Control
Outdoor Unit Sound Pressure Level at Cooling 1
Sound Pressure Level at Heating 2
External Finish Color
Dimensions
Weight
Total Capacity 22-130
Indoor Unit ModelQuantity
Remote Controller Type
Type
Refrigerant Charge
Oil
Gas Side OD Refrigerant Pipe
Liquid Side OD
Height Difference (Max)
Maximum Distance between (Outdoor unit and farthest indoor unit)
Refrigerant Pipe Length Maximum Pipe Length -Branch box to Indoor Unit
Total Maximum line length between Branch Box and All Connected Indoor Units
Total Length (Max)
Connection Method IndoorOutdoor
Includes both branch boxes if there are two
Branch Boxes (At least one branch box required)
Btuh
W
Btuh
Btuh
W
Btuh
Btuh
W
Btuh
A
A
Type x Quantity
Motor Output (kW)
Model (Type)
Motor Output (kW)
CFM
dB(A)
dB(A)
W In
D In
H In
Lbs
Btuh
Lbs Oz
Type (fl oz)
In
In
Ft
Ft
Ft
Ft
Ft
4800048000
57806470
54000
5400054000
48205270
60000
3300034700
29503390
3660036550
1 Phase 60Hz 208 230V
AC 208-230V
DC12-24V
32
40
Propeller x 2
0086 + 0086
DC INVERTER-driven Scroll
29
3530
Linear Expansion Valve
54
55
Munsell No 3Y 78 11
37-716
13+1-3 16
53-3 16
278
12000 - 70200
600 - 24000 2-8
Associated with Indoor Unit Model
R410A
18 112
FV50S (73)
58
38
6698 4
230
49
197
377
FlaredFlared
Compatible with the MSZ-A MSZ-FO MSZ-FE MSZ-GE MFZ-KA SEZ-KD PLA and PEAD series indoor units
NOTES Test conditions are based on AHRI 210240 One indoor unit is turned off during low-speed testing under the new test conditions Systems actually exhibit higher energy efficiencies during normal operation
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F (35deg C) WB 75deg F (24deg C)
2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 4]0 F (8deg C) WB 43deg F (6deg C)
3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 17deg F (-8deg C) WB 15deg F(-9deg C)
4 66 applies to installations when the outdoor unit is installed below the indoor unit
Power factor equals 97 percent
Specifications are subject to change without notice
Note Maximum installed capacity is the maximum total of all connected indoor units NOT the maximum capacity produced
Only a single Lineset is needed from the outdoor unit to branch box
See page 25 for MXZ-B information on efficiency
Required Branch Boxes for MXZ-SB4BNA (Maximum of 2 branch boxes can be connected to one outdoor unit requires joint MSDD-50AR-E or MSDD-50BR-E)
s c d N o J ro Vl
0 ro n 3i n OJ d o J U)
PAC-AKA51 BC Branch Box
PAC-AKA31 BC Branch Box LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 23
MSZ WALL-MOUNTED INDOOR UNITS (FOR MXZ-8 OUTDOOR UNITS)
R
(MSZ-GE12NA MODEL SHOWN)
-000 IIIIIII 9000 9000 12000 12000 14000 17200
Heating at 4r Rated Capacity Btuh 7200 10900 10900 14400 13600 18000 21600
F2 Power Supply I Phase Cycle Voltage J -phase 60Hz 208 230V 3
Iindoor Outdoor S1 S2 AC 208 230V
Iindoor Outdoor S2 S3 DC12-24V Voltage
Iindoor Remote vomr Iller Wireless Type (Optional Wired vomroller DC 12V)
IMCA A 10 IFan Motor FLA 076
DRY 162-226shy145-170shy
162-226shy205-272shy 230-275shy
Airflow at Cooling (CFM)
145-170-237-321-399 339-381
237 -321shy381-410
335-420shy 339-420shy(Quiet-Lo-Med-Hishy 399 533 533 Super Hi or Lo-Med-
WET 144-202shy109-134shy
144-202shy170-237shy 194-240shy
Fan Hi-Powerful)1 (CFM)
109-134-201-286-364 307-343
201-286shy350-367
300-385shy 304-385shy364 498 498
Airflow at Heating 145-170shy 145-170shy 145-170shy 205-247shy 230-275shy
(Quiet-Lo-Med-Hi- WET 233-321shy 237-321shy
166-240shy237-321shy
166-240shy304-367shy 339-431shy
Super Hi or Lo-Medshy (CFM) 406 406
367 -381 406
399-420 463 512
Hi-Powerful) 2 Sound Pressure Level at Cooling
19-22-30shy 26-32-38shy 28-33-38shy(Quiet-Lo-Med-Hi-Super Hi or Loshy dB(A) 19-22-30-37 -43 22-31-39-42
37-45 22-33-43-45
44-49 44-49Med-Hi-Powerful) 1
Sound Pressure Level at Heating 19-22-30shy 26-30-35shy 28-33-38shy
(Quiet-Lo-Med-Hi-Super Hi or Loshy dB(A) 19-22-30-37 -43 22-31-40-42 37-43
22-23-43-44 40-46 43-48
Med-Hi-Powerful) 2
I External Finish Color Munsell No 10Y 92 02
IWln 31 middot716
Dimension Unit 10 In 9 18 10-18 9middot18 10-18 9-18
IH In 11-58
I Weight Unit ILbs 22 27 22 27 22 I Field Drainpipe ~D lin 58 Remote Con-
Type Wireless Remote (Optional Wired Controller) troller
ITvpe B41QA Refrigerant ~s$ideOD lin 38 Pipe I Liquid Side 00 In 14
Connection IndoorOutdoor FlaredFlared
Method
1~
II 18000 22500
21600 27600
388-469shy 38$-469shy628-738 628-738
347-420shy 347-420shy562-661 562-661
388-469shy 388-469shy628-738 628-738
34-41-49-53 34-41-49-53
32-41-49-52 32-41-49-52
43-516
9-38
12-1316 37
58 38
MXZ-2B20NA is also compatible with the MSZ-A and MSZ-FD series indoor units NOTES Test conditions are based on AHRI 210240
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F(6deg C) 3 Indoor units receive power from outdoor units through field-supplied wiring
Specifications are subject to change without notice LIMITED WARRANTY Seven-year warranty on compressor Five-year warranty on parts For data on specific indoor unit combinations see page 21
SEZ DUCTED INDOOR UNIT (FOR MXZ-8 OUTDOOR UNITS)
I
Notes 1 Cooling-Indoor DS 80deg F(267deg C) WS 67deg F(194deg C) Outdoor DS 95deg F (35deg C) WS 75deg F(239deg C)
2 Heating-Indoor DS 70deg F(211 deg C) WS 60deg F(156deg C) Outdoor DS 47deg F (83deg C) WS 43deg F(61 deg C)
3 External static pressure is factory set to 006 WGAdjustable via the
1---------t---+-----L-------------1~---__I PAR-21MAA
1--_____----__________+-____---L____----~_____________1 4 Indoor units receive power
jE~~~~-------------r----1-----~-~~~~~~~~-----___1 from outdoor units through fieldsupplied interconnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven-year warranty on compressor Five-year
1---------------------+---+------------------------1 warranty on parts
~--__I_~----------+-------~l----------I For data on specific indoor unit combinations see page 21 - 23
I--~------+~-----------~----------r_------------I
- Reference page 17 for SEZ static performance curves
24 MITSUBISHI ELECTRIC
25-30-35-40 26-31-36-41 35-38-42-46
25-30-35-40 28-31-36-41 35-38-42-47
MFZ FLOORLOW WALL INDOOR UNIT (FOR middotMXZ-8 OUTDOOR UNITS)
------shy
-==
Airflow at Heating (CFM) 177-198-219-332 184-201-219-335 261-275-297-434
Voltage
Fan
Airflow at Cooling (Lo-Med-Hi-Super Hi)1
169-205-251-314 251-279-325-394
163-197-241-303 170-207-252-309 241-269-313-379
(Lo-Med-Hi-Super Hi) 2
SLZ CEILING-RECESSED INDOOR UNIT (FOR MXZ-8 OUTDOOR UNITS) EFFICIENCY RATINGS
Voltage
Fan
Galvanized-steel SheetsMunsell 64Y 89 04
Refrigerant Pipe
Model Indoor Unit Type SEER HSPF
MXZ-2B20NA-1
Non-dueted 18 89
Dueted and Non-dueted 1675 87
Dueted 155 85
MXZ-2B20NA-1 ENERGY STAR amp
TAX CREDIT 2 x MSZ-GE09NA 18 89
MXZ-3B24NA
lJon-dueted 175 93
Dueted and Non-dueted 1625 89
Dueted 150 85
MXZ-3B24NA ENERGY STAR amp
TAX CREDIT
2 x MSZ-GE06NA 1 x MSZ-GE09NA
175 93
MXZ-3B24NA ENERGY STAR amp
TAX CREDIT
2 x MSZ-GE06NA 1 x MSZ-GE12NA
175 93
MXZ-3B30NA
Non-dueted 175 105
Dueted and Non-dueted 16 100
Dueted 145 95
MXZ-4B36NA
Non-dueted 18 93
Dueted and Non-dueted 16 5 92
Dueted 150 9 0
MXZ-BB4BNA
Non-dueted 15 87
Dueted and Non-dueted 14B B8
Dueted 147 89
Connection IndoorOutdoor FlaredFlared
Method
Notes 1 Cooling-Indoor DB 80deg F(267deg C) WB 67deg F(194deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(239deg C) 2 Heating-Indoor DB 70deg F(21 1 deg C) WB 60deg F(156deg C) Outdoor DB 47deg F(83deg C) WB 43deg F(61 deg C) 3 Indoor units receive power from outdoor units through field supplied interconnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 25
Notes 1 Cooling-Indoor DB 80deg F(267deg C) WB 67deg F (194deg C) Outdoor DB 95deg F (35deg C)WB 75deg F (239deg C)
2 Heating-Indoor DB 70deg F(211deg C) WB 60deg F (156deg C) Outdoor DB 47 F (83deg C) WB 43deg F (61 deg C)
3 Indoor units receive power from outdoor units through field supplied interco(lnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven -year warranty on compressor Five-year warranty on parts
Presently there is no 1 1 system with the MFZ indoor unit
s c
N o J ro Vl
C ro n ~ n OJ t o J V)
M-SERIES RATING CONDITIONS
INDOOR INTAKE AIR TEMPERATURE
OUTDOOR INTAKE AIR TEMPERATURE
COOLING
MAXIMUM
95degF DB 71 degF WB (MU SUZ MXZ-2B20-13B243B304B36) 90degF DB 73degF WB (MUZY-GE MUZ-FE MUzy-D)
115degF DB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B24 3B304B368B48)
MINIMUM 67degF DB 57degF WB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B201 3B243B304B36)
14degF DB (MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B24 3B304B36) 23degF DB (MXZ-8B48) 6rF DB (MU)
MAXIMUM 80degF DB 6rF WB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B243B304B36)
75degF DB 65degF WB (MUZY-GE MUZY-GA24 MUZ-FE SUZ MXZ-2B20-1 3B243B304B36) 70degF DB (MXZ-8B48)
HEATING
MINIMUM 70degF DB 60degFWB (MUZ-GE MUZ-GA24 MUZ-D MUZ-FE SUZ MXZ-2B20-1 3B243B304B36)
-13degF DB -15degFWB (MUZ-FE) -4degF DB -5degF WB (SUZ MUZ-GE) 5degF DB 4degF WB (MUZ-GA24 MXZ-8B48NA) 6degF DB 5degF WB (MXZ-2B20-1 3B24 3B304B36) 14degF DB 13degFWB (MUZ-D)
MU units operate at intake air temperature down to 10deg Fwith the addition of an ICM-326HM-1 low temperature control
REFRIGERANT TUBING SETS
OPTIONAL ACCESSORIES
REFRIGERANT LINE LENGTH FLARE FLARE _INDOOR UNIT OUTDOOR UNIT
MS-A09WA MU-A09WA 35 MS-A12WA
65 MU-A12WA 35
MSY-GE09NA 65
MUY-GE09NA 40
MSY-GE12NA
65
MUY-GE12NA 65 40
MSY-GE15NA MUY-GE15NA 40
MSY-GE18NA
65
MUY-GE18NA 100 50
MSZ-GE09NA MUZ-GE09NA 65 40
MSZ-GE12NA MUZ-GE12NA 40
MSZ-GE15NA
65
MUZ-GE15NA 40
MSZ-GE18NA
65
MUZ-GE18NA 100 50
MSY-GE24NA MUY-GE24NA 100 50
MSZ-GE24NA MUZ-GE24NA 100 50
MSY-D30NA MUY-D30NA 100 50
MSZ-D30NA MUZ-D30NA 50
MSY-D36NA
100
MUY-D36NA 50
MSZ-D36NA
100
MUZ-D36NA 100 50
MSZ-FE09NA MUZ-FE09NA 40
MSZ-FE12NA
65
MUZ-FE12NA 40
MSZ-GE06091215NA MSZ-FE0912NA
65
MXZ-2B20NA-1 164 4933MFZ-KA0912NA SEZ-KD09 1215NA
MSZ-GE0609 121518NA MSZ-FE091218N MFZ-KA09 1218NA MXZ-3B24NA 164 4933 SEZ -KD09 12 15 18NA SLZ-KA09 12 15NA
MSZ-GE0609 121518NA MSZ-GA24NA MSZ-FE091218NA
MXZ-3B30NA 4933230MFZ-KA091218NA SEZ -KD09 121518NA SLZ-KA09 12 15NA
MSZ-GE0609121518NA MSZ-GE24NA MSZ-FE09 12 18NA
MXZ-4B36NA 230 4933MFZ-KA091218NA SEZ -KD09121518NA SLZ-KA09 12 15NA
MSZ-GE0609 12 15 18NA MSZ-GE24NA MSZ-FE09 12 18NA
MXZ-8B48NA 6698377MFZ-KA091218NA SEZ-KD09121518NA SLZ-KA09 12 15NA
PART NUMBER I USE WITH I DESCRIPTION
Port Adapters and Connection Pipes MAC-A454JP-E MXZ-Series Adapter 38 X12
MAC-A455JP-E MXZ-Series Adapter 12 X38
MAC-A456JP-E MXZ-Series Adapter 12 X58
MSDD-50AR-E MXZ-Series Branch Box Tee Distribution Pipe - Flare Connection between two branch boxes
MSDD-50BR-E MXZ-Series Branch Box Tee Distribution Pipe - Braze Connection between two branch boxes
PAC-493PI MXZ-Series Adapter 14 X38
PAC-SG76RJ-E MXZ-Series Adapter 38 X58
OPTIONAL ACCESSORIES CONTINUED ON NEXT PAGE
49 amp 66 applies to installations in which the outdoor unit is installed below indoor unit26 MITSUBISHI ELECTRIC
OPTIONAL ACCESSORIES (CONTINUED)
PART NUMBER USE WITH DESCRIPTION Control Options and Accessories
M21 JKO 307 M-Series Indoor Units Remote temperature sensor for M-Series indoor units
MAC-397IF-E
MAC-399IF-E
PAC-YU25HT
PAR-21 MM-G
M-Series INVERTER Units
M-Series INVERTER Units
SEZ-KD Indoor Units
Use with P-Series SEZ and for wired M-Series Controller
MA and contact terminal interface - Required to use PAR-21 MM wired wall mount controller with M-Series Systems
CMCN M-NET control adapter I Interface for Mr Slim M-Series MSYZ SEZ I MFZ
External Fan I Heater control relay adapter
Deluxe MA remote controller (Requires MAC-397IF-E for use with M-Series - MSYZ MFZ)
SEZ Wireless remote controller for SEZ units (Requires signal receiver PAR-SA9FA-E)PAR-FL32MA
PAR-SA9CA-E SEZ Wireless signal receiver for SEZ
3-pole disconnect switch 30A 600V turns off power between indoor and outdoor units shyM-SeriesTAZ-MS303
mounts in 2 X 4 utility box and requires standard single gang switch platecover - Low Ambient
ICM-326HM-2 M-Series Non-INVERTER units Low ambient head pressure controller MUZ-GE091215 IVIUZ-FE0912 SUZ-KD091215
Drain pan heaterMAC-640BH-U outdoor unit
MAC-641 BH-U MUZ-GE18 SUZ-KD18 outdoor unit Drain pan heater Filters
MAC-1415FT-E Anti-allergy enzyme filter
MAC-2300FT
MSZlMSY-D3036
Anti -allergy enzyme filter
MAC-308FT
MSYMSZ-GA24
MSZ-FD912 I FE0912 Platinum deodorizing filter
MAC-408FT-E Anti-allergy enzyme filter
MAC-415FT-E
M-Series Indoor Unit - GE09GE12GE15GE18
MFZ-KA Air Cleaning FilterAnti-Aliergy Enzyme Filter
MAC-418FT Anti-allergy enzyme filter
Filter Boxes
FBL1-1
MSZ- FD912 I FE091 2
FB Series Filter Box for SEZ-KD09NA Optional filter box with MERV 8 filters
FB Series Filter Box for SEZ-KD1215NAFBL1-2 Optional filter box with MERV 8 filters
and PEA-A 12M
FBL1-3 FB Series Filter Box for SEZ-KD18NA Optional filter box with MERV 8 filters
Pumps
SI1730-230 MSYZ - 30000 Btuh or greater Sauermann mini condensation pump 230V
S13100-115 MS-Series - non-INVERTER Sauermann mini condensation pump 115V
S13100-230 Sauermann mini condensation pump 230VMSYZ - Less than 30000 Btuh
Miscellaneous BRP-1 Bottom Return Plate for SEZ-KD09NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-2 Bottom Return Plate for SEZ-KD12KD15-NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-3 Bottom Return Plate for SEZ-KD18NA Converts low profile ducted indoor unit from rear return to bottom return
BV12FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderreglnsulated - 12
BV14FSI Use with any Mr Sl im multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 14
BV38FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 38
BV58FSI Use with any IVIr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 58
Condensing unit wall mounting brackets (set of 2) - 440 lb capacity painted steel NOTE CWMB1 IVIU and PU outdoor units Installer is responsible to select and provide suitable hardware and materials to insure proper
mount of bracket to wall
DSD-400N M-Series DiamondBacktrade Platform Stands MUZ-GE18 I MUZ(y)-03036 I
MAC-811DS Drain socket assemblySUZ-KA18
MAC-851DS MUZ-FD0912 Drain socket
MAC-855SG M-Series Air outlet guide
MAC-856SG M-Series Air outlet guide - MXZ-3B24 I 3B30 I 4B36 NA
MAC-860DS MUZ-GE091215 I MUZ-FE0912 Drain socket
MAC-889SG M-Series Air outlet guide- MXZ-2B20NA
MAC-S99SG M-Series Air outlet guide
PAC-SG59SG-E IVIXZ-SB4SNA Air outlet guide (1 piece) I MXZ-SB48NA (Requires 2 pieces)
PAC-SG61 DS-E MXZ-8B4SNA Drain socket - connector
PAC-SG64DP-E MXZ-SB48NA Drain pan
RCMKP1CB lVI-Series Wireless Lockdown bracket for remote controller
lILTRILlTE1 All M-Series Condensing unit mounting pad 16 x 36 x 3
MITSUBISHI ELECTRIC 27
MXZ-8 Series Port Adapter chart Port Adapter Unit Port
Combinations Required Size
MXZ-2B20NA-1
2-zone combinations wi NA
A 38 x both units s12K 14
1-MAC-A454JP-E B 38 x
6+15 14
9+15 1-MAC-A454JP-E
MXZ-3B24NA
All rated 2-zone combina-NA
A 12 x tions 14
All rated 3-zone combina-NA
B 38 x tions 14
C 38 x 14
MXZ-3B30NA
2-zone combinations wi at NA
A 12 x least one unit s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
9 + 24 14
3-zone combinations wi 1-MAC-A455JP-E
all units s12K
All other rated 3-zone NA
comb
MXZ-4B36NA
2-zone combinations wi at NA
A 12 x least one un it s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
6 + 24 14
1-MAC-A456JP-E D 38 x
9 + 24 14
3-zone combinations wi at NA
least two units s12K
3-zone combinations wi 1-MAC-A454JP-E
two units15K
6+6+24 or 6+9+24 1-MAC-A456JP-E
9+9+24 1-MAC-A456JP-E
4-zone combinations wi at 1-MAC-A455JP-E
least three units s12K
6+6+15+15 1-MAC-A454JP-E
6+6+15+15 1-MAC-A454JP-E
Note When using the Pu-A24BA PCA-A24KA or PEAD-A24AA two port adapter will be needed 1-MAC-A456JP-E (12 x 58) A port or 1-PACshySG76RJ-E (38 x 58) B C and D ports and 1-PAC493PI (14 x 38)
28 JMITSUBISHI ELECTRIC
6+6+246+9+24 6+12+249+9+24 9+12+24 or 12+12+24
6+15+24 6+18+24 9+15+249+18+24 12+15+24 or 12+18+24
15+15+24 15+18+24 or 18+18+24
15+24+24 or 18+24+24
Combinations of 4 or more zones
1-PAC-SG76RJ-E
See notes for application below
2
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
See notes for application below
PORT A =38 gas x 14 liquid
PORT B =38 gas x 14 liquid
PORT C =38 gas x 14 liquid
PORT A =38 gas x 14 liquid
PORT B = 38 gas x 14 liquid
PORT C = 38 gas x 14 liquid
PORT D =38 gas x 14 liquid
PORT E =12 gas x 14 liquid
Notes for application bull Check the lineset sizes for your indoor selected models bull Select the branch box or boxes needed for your application bull Compare indoor unit lineset sizes as compared to branch
box sizes bull Connect 15K + indoor units to the larger port on the
(PAC-AKA51 BC) bull Adapt lineset size with appropriate port adapter from
above list bull When using the PU-A24BA or PEAD-A24AA two port
adapter will be needed 1-MAC-A456JP-E (12 x 58) or 1-PAC-SG76RJ-E (38 x 58) and 1-PAC493PI (14 x 38)
-fv
~ DIAMONDBACKtrade
~) BV-Series Ball Valves Model numbers
BV14FFSI BV38FFSI
LISTED 891N REFRIGERANT
BV12FFSI VALVE bull Engineered for Mini-split andBV58FFSI
Multi-split HVAC Units bull Size available 14 38 12 58
bull Full Port Designbull Fully factory assembled bull Furnace brazed and pressure tested bull 700 PSIG Rated bull Each ball valve is equipped with Schraderreg Valve
for refrigerant service bull R-410A Compatible bull Design working pressure 700 PSIG bull Temperature range bull Flare Connections
-40 0 F to +3250 F (-400 C to + 1490
C) bull Forged brass body and seal cap bull Teflonreg seals and gaskets (no synthetic a-rings) bull Seal cap design permits valve operation without
removal of seal cap bull Suitable for use with R-11 R-22 R-123 R-125
R-134A R-236FA R-4202A R-402B R-404A R-407C R-410A R-500 R-502 and R-507
bull One year limited materials and workmanship
Part Number SAE Flare
A B C 0 E F
BV14FFSI 14 619 260 180 122 142 110
BV38FFSI 38 630 267 180 122 142 110
BV12FFSI 12 651 267 180 122 142 110
BV58FFSI 58 664 267 180 128 142 110
Ball valves come With an insulation piece warranty on Ball Valves
~ DIAMONDBACKtrade
~) Platform Stands
Lift the Mitsubishi Electric Comfort Solution
outdoor unit to new heights with our Diamondback Platform Stands
bull Easy to install
bull Available for all sizes of Mr Slim outdoor units
bull Color matched to the outdoor units
Model Number DSD-400N
L 15-34 x W 3-14 x H 3-14
r
)MITSUBISHI ELECTRIC 29
~ DIAMONDBACKtrade LINESETS
~~
Twin-Tube Lineset Insulation Design
bull Balanced outside diameter for uniform coiluncoil position stability
bull Minimum 12 insulation thickness on both tubes Diamondback Advantages include the following features
bull Quick efficient and economical field installation using factory applied Twin Tube insulation and flare connections with flare nuts mounted
bull Correct lengths for reducing waste and time
bull Quality consistency and economy
bull All Diamondback Lineset tubing is tested in accordance with ASTM E243
Filter Boxes
FB Series filter boxes are available in compatible sizes for all Mr Slim horizontal ducted indoor units
FBL 1 filter boxes include 1 thick pleated MERV 8 filter(s) installed Filters are tested in accordance with ANSIASHRAE Standard 522 and Rated Class 2 under UL Standard 900
The cabinet is constructed of non-insulated 20 gauge G-60 galvanized
FBL1-1 FB Series Filter Box for SEZ-KD09NA
FBL1-2 FB Series Filter Box for SEZ-KD12KD15-NA
FBL1-3 FB Series Filter Box for SEZ-KD18NA
steel with foam gasket and provides an air-tight connection to indoor unit and access door Gasket material complies with UL 723 requirements
A screw-through cabinet design for secure attachment to indoor unit and return connection in rear is easily field-converted to bottom return
30 MITSUBISHI ELECTRIC
bull
bull
bull
bull
bull
bull
LINE-HIDE~ Put a professional finish on air-conditioning
installations with an easy-to-install modular
system that beautifies exteriors and
protects Linesets drainlines and wiring
Can be use it indoors too Meets UL94v-O for interior applications
Has snap-on covers and a full selection of couplings elbows T-joints caps and more for any application complex or simple
Offers high-quality PVC with UV inhibitors for outdoor service in all weather conditions
Can be painted with most house paints to match exterior decors
Is not just for HVAC Hide any exterior cabling piping or wiring
Available in four sizes 2-14 3 4 and 6 tubes
Download a brochure at wwwline-hidecom to find out more information
For more information on our CITY MULTI VRF product line visit our website at wwwmitsubishiprocom
_lIJrUlllln ~ ~IIII1 fInll l
~
l bull bull
JMITSUBISHI ELECTRIC 31
Mitsubishi Electric System Technologies user-friendly zoned residential personalized comfort solutions
Mitsubishi Electric indoor units are easy to install-practically anywhere bull High on the wall to blend into a room without taking up window space bull In the ceiling or below the floor out of sight bull Low on the wall to be unobtrusive
Our systems are the perfect way to cool or heat any single room or multiple rooms in homes or office
Heat-pump systems feature auto mode which automatically switches between cooling and heating in response to changing needs Our systems are nearly silent their fans deliver air quietly and continuously with only a gentle whoosh for constant circulation and filtration For this reason Mitsubishi Electric split-zoning systems have long been the choice for thousands of homes churches schools and libraries across the US and the world
Technology Benefits of Mitsubishi Systems
Features Benefits INVERTER-DRIVEN Maximizes energy savings by making sure only the energy needed COMPRESSORS to cool or heat an area perfectly is used
Installs quickly and easily having no need for major constructionEASY INSTALLATION and remodeling
COMPLETE ZONE Realizes maximum control and energy efficiency by cooling CONTROL and heating only those spaces in use
ADVANCED Creates a comfortable environment no matter what conditions areMICROPROCESSOR outside with our advanced self-monitoring controlsTECHNOLOGY
PERSONAL COMFORT Offers comfort control of temperature fan speed and air direction CONTROL in the specific zone with dedicated controller
WASHABLE LONG-LIFE Improves air quality and saves money by washing ANTI-ALLERGEN FILTERS rather than replacing the filter
AUTO COOUHEAT Switches automatically from cooling to heatingCHANGEOVER (MUZISUZ systems) if desired
ENVIRONMENTALLY Uses R41 OA an environmentally friendly refrigerantFRIENDLY REFRIGERANT
Energy Effic iency Recognized Mitsubishi Electric split-zoning cooling-only and heat pump systems are so energy efficient that currently 18 systems of our INVERTER-driven systems are ENERGY STAR rated This can mean big savings
Add in the federal tax credit and local government and utility rebates and you have an ENERGY STAR opportunity to enjoy comfort at substantial savings PARTNER
For details on qualifying systems go to wwwmitsubishicomfortcomtaxcredit or use your smart phone to scan the tag to the left and go to the page
Visit wwwdsireusaorg for information on available local rebate opportunities from state or utility companies
Get the free app for your smart phone at httpgettagmobi
4 ~MITSUBISHI ELECTRIC
----
MITSUBISHI ELECTRIC 5
Innovative Variable-speed Compressor Technology Sophisticated electronic control systems detect any changes in room or zone temperashyture and-like a cars cruise control-automatically adjust the speed of the outdoor units INVERTER-driven compressor and electronic linear expansion valve (LEV) position for Rprecise capacity control The INVERTER-driven compressor is unlike those found in other systems which only start and stop repetitively Special components within the INVERTER compressor such as high density windings in the motor that increase the magnetic flux and artificial magnets in the rotor to reduce its weight allowi it to operate at higher energy efficiencies with better performance than ever before while producing low sound levels both during start-up and operation
MUZ-FE H2i Heating Capacity at Low Temperatures
120 - -~ I
gc100 --~--~~~~~~--~~~~~~
~ 80~~~~~~-+---~--~~~~--+-~shy()
OJ 60 ------+---j----t---t----t----t---J ~ _ MUZ-FE12NA
Q) 40 _ MUZ-FE18NA I __ UNITARY
~ 20 ---r--+---r--+--~--r-~~~--~~shy
o -13 -4 0 5 10 17 25 30 35 40 47
Outdoor Temperature Degrees FWB
Includes correction for defrost
-
~ l
~ Q) a E ~ 0 ~
o
Heat and Lots of It In addition to the already innovative INVERTER-driven compressor the MSZ -FE high-efficiency systems are also ENERGY STARreg rated and tax credit qualified up to 26 SEER delivering exceptional heating performance
These systems provide heating down to -130 F outdoor ambient and produce up to 100 heating capacity at 50 F MSZ-FE0918 92 capacity at 50 F for MSZ-FE12 Our systems provide year-round comfort in extreme climates while being extremely energy efficient There usually is no need for resistance electric or other supplemental energy-consuming devices with this performance
1seesensor i-seetrade Sensor (MSZ-FE0912NA models only)
The i-see Sensor detects temperature variations in hardshyto-control ceiling and floor areas and controls the airflow up to a wide lateral angle for ultimate comfort (900 angle in cooling mode) By scanning the room and adjusting airflow based on ambient temperature readings MSZ -FE systems achieve superior coolingheating performance with extremely efficient operation
INVERTER model Reaches set point quickly and uniform temperatures are maintained by finely-tuned control of compressor speed
Conventional model Takes longer to reach set point while the temperature is adjusted by switching the compressor off and on consuming additional energy
~ f------------ --_Time ---
Vl l
09shy(I)
I
N 0 l (I)
Vl ltV) (I)
3 0 lt(I)
s (I)
~ OJ l 0 --I (I) n r l 0 0
~
Superior Operation
Advanced Control Technology Through Mitsubishi Electrics advanced controls technology the indoor unit is powered by the outdoor unit Three polarity sensitive wires plus a ground conductor run from the outdoor to the indoor unit providing both power and data communication An advanced wireless remote control is standard on all ductless models An optional wired on-the-wall controller is available for wallshymountedfloor-standing indoor units on INVERTER systems (also requires MAC-397 If adapter) while standard on SEZ -KD ducted units
Quiet Operation Do you hear that No Mitsubishi Electric systems operate at low sound levels our indoor units produce decibels barely at a whisper level Compare to other common sounds
Police siren 118 decibels Circular saw 107 decibels Vacuum cleaner 74 decibels Whisper-tone voice 35 decibels Library reading room 33 decibels Our Indoor Units 19 - 34 decibels (at low speed)
Did you hear that We hope you did
Warm Air No Drafts Our hot-start heat-pump technology provides warmth from the beginning The fan increases in speed as the coil is warmed reducing drafts so when you want warm air you get it
TEMP
88
System Control Mitsubishi Electric offers a comprehensive remote controller that can adjust temperature fan speed and more Choose from four modes COOL HEAT AUTO and DRY The controller also has a 12-hour ONOFF timer for one-button control of your personal comfort
Easy to Maintain With easily accessible filters little or no ductwork to clean and simple wiring between the indoor and outdoor units Mitsubishi Electric systems require minimal maintenance providing another level of convenience
Auto Changeover on Heat-Pump Systems (MUZISUZ outdoor units)
Our heat-pump systems sense whether a space needs cooling or heating and automatically switch modes as needed to maintain a consistent temperature You can set it and forget it
6 MITSUBISHI ELECTRIC
----
Hybrid Catechin pre-filters -- shy
- shy
Total Comfort
Additional Air Circulation With the WIDE VANE or SWING mode available on the MSY(Z)-GE24 D3036NA there is an option for ~~~~lQcnborizontal airflow directions that provide 150
0
of lateral airflow for greater conditioned air circulation
-- -----_ ~~ iii
~~---- 150
0
Multiple Filters for Cleaner Healthier Ai r Mitsubishi Electric indoor units use a sophisticated multi-part filter system to remove contaminants such as allergens viruses and bacteria from the air
A hybrid catechin pre-filter absorbs odorshycausing gases The hybrid-coating process makes the catechin filter washable and - if properly maintained with regular cleaningshyremains effective for up to 10 years
A Blue-enzyme anti-allergen filter reduces germs bacteria and viruses and helps trap dust pollens mites and other particles The filter uses an enzyme catalyst to help break down the sulfur atom bonds in allergen proteins transforming them into non-allergen proteins and effectively cleaning the air The filter should be cleaned regularly to maintain efficiency
STANDARD FILTER SYSTEM (USED IN MSYMSZmiddotGElFE18GND MODELS)
Front Panel - shy
Blue Enzyme anti-allergen filter
ENHANCED FILTER SYSTEM (USED IN MSZmiddotFE0912NA MODELS)
Programmable Comfort Smart Set featured on MSZ-GE systems provides the option to program multiple settings into one quick-press feature providing an additional level of comfort control
The POWERFUL mode (found on select systems) is available to cool or heat any desired space quickly by lowering the set temperature in cooling mode or raising the set temperature in heating mode both by T F In POWERFUL Mode the fan speed increases for 15 minshyutes then the system resumes all standard operations
Vl l
OQ
([) I
N o l ([)
Vl lt(n r-+ ([)
3 o lt ([)
s ([)
~ OJ l a --I ([) nr l o o ~
The high-efficiency MSZ-FE0912NA indoor units incorporate the standard Catechin filter plus two more filters for triple filtration The second filter a Blueshyenzyme filter made of a fibrous material renders allergens harmless by using enzymes The third filter a Platinum Catalyst Deodorizing filter has a ceramic surface absorption element and uses nanotechnology for high-power odor absorption Periodic cleaning following the recommended procedures will maintain filter effectiveness for up to two years This combination of filters provides a complete air-purifying system within the ultimate comfort solution
Front Panel - shy
Hybrid Catechin pre-filters
cJ shy Blue Enzyme anti-allergen filter
I
MITSUBISHI ELECTRIC 7
---- -- -- -
System Lineup RESIDENTIAL AND LIGHT COMMERCIAL SYSTEM MODELS AND CONTROLLERS
SINGLE
MSMU Air Conditioners
9500 to 12000 Btuh 13 SEER
bull Provides cooling-only system bull Non-INVERTER rotary compressor bull Ideal for spaces such as
bedrooms garages out-buildings video monitoring
- ROOM WALL-MOUNTED Ale (cooling only)
MSYMUY Air Conditioners
3800 to 34600 Btuh Capacity Range 151 - 21 SEER
~ -
bull Cooling-only system bull INVERTER-driven compressor bull WIDE VANE for a wider angle of airflow 150
0
from left to right (on GE24D30D36 models)
bull Ideal for spaces such as bedrooms garages large open rooms and bonus rooms
SINGLE-ROOM WALL-MOUNTED HEAT PUMPS (coo lin g and heatin g)
MSZMUZ Heat Pumps
3800 to 33200 Btuh Capacity Range
145 - 21 SEER 82 - 10 HSPF
bull Uses INVERTER-driven compressor bull Provides cooling and heating in a wide range
of capacities bull Offers a WIDE VANE for a wider angle of airflow 1500 from
left to right (on GE24D30D36 models) bull Ideal for applications in bedrooms home offices living
rooms dining rooms bonus rooms basements kitchens guard houses and more
Up to 26 SEER
MSZMUZ-FE0912NA High - Efficiency Heat Pumps
2800 to 25200 BtuH capacity range 202 - 26 SEER
10 - 106 HSPF
bull INVERTER-driven compressor bull Quiet operation as low as 19dB(A) bull i-seetrade Sensor technology bull Enhanced filtration system bull H2ireg high~heat capabilities (see page 12 amp13)
MSZ-FE09 is 100 percent at 50 F MSZ -FE12 is 92 percent at 50 F MSZ-FE18 is 100 percent at 50 F
SI NGLE-ROOM LOW WALL or FLOOR-STANDING UNIT (fo r use with MXZ -8)
New to our lineup is a Low Wall or Floor-Standing model that can fit into those once difficult installations
MFZ These units provide comfort in spaces such as (For use with MXZ-8 finished attics with knee walls basements with Outdoor Units only) low ceilings and glass-walled sunrooms
bull Provides cooling and heating in Mounted three inches above floor level these models a wide range of capacities provide conditioned air two vents and provide direct
bull Two outlet air vents front-panel access to the filter for easy cleaning The - Upper vent for cooling or heating MFZ can even be recessed in a wall during installation - Bottom vent for heating only provided proper clearances are maintained (Currently there is
bull Flush or recessed installation no 1 1 system with M FZ)
8 MITSUBISHI ELECTRIC
SING LE -ROOM HORIZONTAL- DUCTED HEAT PUMPS (coo lin g and heat ing)
WIR ELESS and W IR ED REMOTE C O NTRO LLERS
PAR-21 MAA Wireless remote controller Set Temperature
for wall-mounted and floor-standing indoor units ----- OnOff
Timer Menu Fan Speed
Fan Speed Filter
Test Run Set Time
CheckEcono Cool
Airflow UpDown Timer OnOff
Louver
Ventilation
Reset ---- shy Optional wired controller for the SEZ SLZ and MFZ indoor units (Optional controller for wall-mounted is
available and floor-standing indoor units Unit requires MAC-397 If adapter)
MHK1 WIRELESS REMOTE CONTROLLER Exclusive for INVERTER-driven Mr Slimreg Systems
Wireless Technology a SEZ and SLZ 11 systems with SUZ outdoor unit only
MIFH1
MITSUBISHI ELECTRIC 9
AMITSUBISHI ELECTRIC
l~ 1000
~r t ~~~O
MRCH1
rtj n-shy --1r-a-1-shy
Mode ------ -- shy
SEZSUZ If your customer is looking for discrete zoned comfort then a short-run ducted unit Heat Pumps is the right solution As a stand-alone system or connected to a MXZ multi-room
3800 to 19000 BtuH system the SEZ ducted units provide energy efficiency quiet operation and a Capacity Range compact design for quick easy instqllation hidden either in the ceiling or beneath
15 SEER _---~~mm the floor 175 - 10 HSPF
J ~ All of the 11 systems are ENERGY STAR certified and two systems qualify for
~ the federal tax credit These systems provide customers with an environmentally friendly indoor unit with a similar installation and familiar style
These SEZ indoor units also connect to MXZ multi-zone systems providing a wide array of installation options to best fit any application
SING LE -R OO M C EI LING -REC ESSED CASSETTE UN IT
SLZSUZ Heat Pumps The SLZ -KA ceiling-recessed units casette offer a wide
3100 to 22200 BtuH air-flow pattern for better air distribution in a less obtrusive Capacity Range style These indoor units can be used in 11 heat pump
15 - 16 SEER and multi-zone systems providing more options to your customers Install SLZs in a hard ceiling (with a access panel for
bull 96 HSPF
servicing) or in a 2x2 extra space drop ceiling With a built-in drainshylift mechanism for condensate removal and a 4 ventilation-air intake knockout option and multiple options for the 11 systems the SLZ
~ ~ handles a variety of installation needs
Two of the three 11 systems are ENERGY STAR qualified
Vl l
OQ
(I) I
N o l (I)
Vl ltV (I)
3 Vl r o ~ n OJ V (I)
1shy(MS-A12WA MODEL SHOWN)
MS COOLING-ONLY
IJON-INVERTER
Model Name Indoor Unit
Outdoor Unit
MS-A09WA MS-A12WA
MU-A09WA MU-A12WA
Cooling 1
Rated Capacity Btuh 9500 12000
Capacity Range Btuh
Total Input W 870 1070
Energy Efficiency SEER 13
Moisture Removal Pintsh 27 32 Sensible Heat Factor 068 070
Power Supply Phase Cycle Voltage 1 Phase 60Hz 115V 2
Voltage Indoor - Outdoor L1-N AC 115V Indoor - Outdoor N-2 AC 115V Indoor - Remote Controller Wireless Type
Indoor Unit
MCA A 12
Fan Motor FLA 095
Airilow (Lo-Med-Hi Poweriul)
DRY (CFM) 183-261-335-367 222-286-406-446
WET (CFM) 162-233-300-328 198-254-363-399
Sound Pressure Level (Lo-Med-Hi)
dB(A) 26-32-40-42 33-38-45
External Finish Color Munsell No 1OY 9202
Dimension Unit
W In 30-1116
0 In 8-14
H In 11-34
Weight Unit Lbs 23
Field Drainpipe Size 00 In 58
Outdoor Unit
MCA A 14 16
MOCP (Time Delay) A 15 20
Fan Motor FLA 063 093
Compressor
Model (Type) Single Rotary
RLA 93 1082
LRA 47 56
Airilow CFM 1083 1327
Refrigerant Control Capillary Tube
Sound Pressure Level (Cooling) 1
dB(A) 47 52
External Finish Color Munsell No 3Y 7811
Dimensions
W In 31-12 33-716
0 In 11-14 11-716
H In 21-58 23-1316
Weight Lbs 78 96
Remote Controller Type Wireless Remote
Refrigerant
Type R410A Charge Lbs Oz 25 31
Oil Type (FI Oz) NE022 (108)
Refrigerant Pipe
Gas Side 00 In 38 12
Liquid Side 00 14
Height Difference (Max) Ft 35
Length (Max) 65
Connection Method IndoorOutdoor FlaredFlared
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling) - Indoor DB 800 F(270 e) WB 670 F(190 e) Outdoor DB 950 F(350 e) WB 750 F(240 e) 2 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice
LlIVIITED WARRANTY ISeven-year warranty on compressor Five-year warranty on parts
10 MITSUBISHI ELECTRIC
I
R ---I Vl
J(MSY-GE1 7NA MODEL SHOWN) OQ
MSY COOLI NG-ON LY (CO NT ) CD N o J CD
s Vl OJ J
Cooling 1 0shy
s Vl -lt Vl
~~~~~-=~------~~--------------------------~~~~----------------------------~ jVoltage
205-272-335shy145-170-237 -321-399
420-533 170-237 -300shy
385-498
26-32-38-44-49Indoor Unit
Outdoor Unit
194-240-304shy385-498
28-33-38-44-49
388-469-628-738
347-420-562-661
34-41-49-53
CD n 3-i n OJ 0389-639-848 o J350-576-763 V)
32-42-49
2 9 43Refrigerant
FV50S (040) NE022 (295)
Refrigerant Pipe
Refrigerant Pipe Length
Connection IndoorOutdoor FlaredFlared
Method
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling) - Indoor DB 80deg F(27deg e) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice
LIMITED WARRANTY ISeven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 11
~ (MSZ-FE12NA MODEL SHOWN)
MSZ HEAT PUMP TAX
CREDIT
Model Name
Cooling 1
Indoor Unit Outdoor Unit
Rated Capacity Btuh
MSZ-GE09NA MUZ-GE09NA
9000
MSZ-FE09NA HshyMUZ-FE09NA bull
9000
MSZ-GE12NA MUZ-GE12NA
12000
MSZ-FE12NA MUZ-FE12NA
12000
H-bull MSZ-G MUZ-G
14000
Capacity Range Btuh 3800-12200 2800-9000 3800-13600 2800-12000 3100-18200
Total Input W 660 (205-1200) 580 (160-650) 960 (205-1300) 930 (160-960) 1080 (160-2000)
Energy Efficiency SEER 21 26 205 23 21
Moisture Removal Pintsh 15 21 25 29 27
Sensible Heat Factor 082 076 074 073 080
Heating at 47deg F 2
Rated Capacity Btuh 10900 10900 14400 13600 18000
Capacity Range Btuh 4500-14100 3000-18000 5500-18100 3000-21000 4800-20900
Total Input W 760 (255-1200) 710 (150-2250) 1170 (340-1660) 950 (150-2250) 1600 (270-2010) HSPF (IV) BtuhlW 10 106 10
Heating at 17deg F3 Rated Capacity Btuh 6600 6700 8800 8300 11300 Rated Total Input W 700 650 900 800 1150 Maximum Capacity Btuh 8700 12500 11200 13600 15900
Heating at 5deg F Maximum Capacity Btuh 7061 10900 9194 12500 13022
Power Supply Phase Cycle Voltage 1-phase 60Hz 208 230V 4
Voltage
Indoor - Outdoor S1 - S2 AC 208 230V
Indoor - Outdoor S2 - S3 DC12-24V
Indoor - Remote Controller Wireless Type (Optional Wired Controller DC 12V)
Indoor Unit
MCA A 10
Fan Motor FLA 076
Airflow at Cooling (Lo-Med-Hi-Super HI-Powerful) 1
DRY (CFM) 145-170-237-321-399 162-226-339-381 145-170-237-321-399 162-226-381-410 205-272-335-420-533
WET (CFM) 109-134-201-286-364 144-202-307-343 109-134-201-286-364 144-202-350-367 170-237-300-385-498
Airflow at Heating (Lo-Med-Hi-Super HI-Powerful) 2
WET (CFM) 145-170-237-321-406 166-240-367-381 145-170-237-321-406 166-240-399-420 205-247 -304-367-463
Sound Pressure Level at Cooling (Lo-Med-Hi-Super HI-Powerful) 1
dB(A) 19-22-30-37-43 22-31-39-42 19-22-30-37-45 22-33-43-45 26-32-38-44-49
Sound Pressure Level at Heating (Lo-Med-Hi-Super HI-Powerful) 2
dB(A) 19-22-30-37-43 22-31-40-42 19-22-30-37-43 22-33-43-44 26-30-35-40-46
External Finish Color Munsell No 10Y 92 I 02
Dimension Unit
Wln 31-716 31-38 31-716 31-38 31-716
0 In 9-118 10-18 9-18 10-18 9-18
H In 11-58
Weight Unit Lbs 22 27 22 27 22
Field Drainpipe Size 00 In 58
Outdoor Unit
MCA A 12
MOCP A 15
Fan Motor FLA 050 056 050 056 050
Compressor
lVIodel (Type) DC INVERTER-driven DC INVERTER-driven Twin
Rotary DC INVERTER-driven DC IIWERTER-driven Twin Rotary
RLA 66 86 66 86 74
LRA 82 108 82 108 93
Airflow (CoolingHeating) CFM 11511225 1102 11187 12291172 1102 11187 12431229 Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(A) 46 48 49 48 49
Sound Pressure Level at Heating 2 dB(A) 50 49 51 49 51
External Finish Color Munsell No 3Y 78 11
Dimensions
Wln 31-12
0 In 11-114
H In 21-58
Weight Lbs 66 80 77 80
Remote Controller Type Wireless Remote (Optional Wired Controller)
Refrigerant
Type R410A
Charge Lbs Oz 112 29
Oil Type (fl oz) NE022 (108) NE022 (152)
Refrigerant Pipe Gas Side 00 In 38 12
Liquid Side 00 In 14 14
Refrigerant Pipe Length Height Difference (Max) Ft 40
Length (Max) Ft 65 I
Connection Method IndoorOutdoor FlaredFlared
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg e) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg e) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg e) Outdoor DB 47deg F(8deg e) WB 43deg F(6deg e) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg e) Outdoor DB 17deg F(-8deg e) WB 15deg F(-9deg e) 4 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice
12 +MITSUBISHI ELECTRIC LIMITED WARRANTY ISeven-year warranty on compressor Five-year warranty on parts
- shy(MSY(Z)-D30NA MODEL SHOWN)
Vl J
09 (I)
I
N o J (I)
s Vl N Vl
-0 (I) n 31 n OJ 0 o J V)
Model Name Indoor Unit MSZ-GE18NA MSZ-FE18N MSZ-GE24NA MSZ-D30NA MSZ-D36NA
Outdoor Unit MUZ-GE18NA MUZ-FE18rK MUZ-GE24NA MUZ-D30NA MUZ-D36NA Rated Capacity Btuh 17200 18000 22500 30700 33200
Capacity Range Btuh 3700-18700 8200-25200 8200-31400 9800-30700 9800-33200
Total Input W 1640 (240-2070) 1270 (570-2280) 1800 (570- 3580) 3850 (620-3850) 4360 (620-4360) Cooling 1
Energy Efficiency SEER 192 202 190 145
Moisture Removal Pintsh 46 27 27 99 11 3
Sensible Heat Factor 071 084 075 064 062
Rated Capacity Btuh 21600 21600 27600 32600 35200
Capacity Range Btuh 3500-25200 7500-29700 7500-36900 8700-34000 8700-36000 Heating at 47deg F 2
Total Input W 1900 (230-2680) 1540 (520-2240) 2340 (520- 3650) 3360 (520-3600) 3840 (520-4100)
HSPF (Region IV) BtuhIW 10 103 10 82
Rated Capacity Btuh 13400 11700 16000 19500 21800
Heating at 17deg F 3 Total Input W 1450 2180 3290 2400 2820
Maximum Capacity Btuh 17200 19300 24600 20800 22800 Heating at 5deg F
Maximum Capacity Btuh 13562 21 600 21160 16305 19090
Power Supply Phase Cycle Voltage 1 Phase 60Hz 208230V 4
Indoor - Outdoor S1-S2 AC 208 230V Voltage Indoor - Outdoor S2-S3 DC12-24
Indoor - Remote Controller Wireless Type (Optional Wired Controller DC12V) MCA A 10 Fan Motor FLA 076
DRY (CFM) 230-275-339-420-533 388-469-628-738 388-469-628-738 389-639-848 Airilow (Cool) (Lo-Med-Hi-Super HI-Poweriul) 1
WET (CFM) 194-240-304-385-498 347-420-562-661 347-420-562-661 350-576-763
Airilow (Heat) (Lo-Med-Hi-Super HI-Poweriul) 2 DRY (CFM) 230-275-339-431-512 388-469-628-738 388-469-628-738 445-639-848
Sound Pressure Level (Cooling) (Lo-Med-Hi-Super 28-33-38-44-49 34-41-49-53 34-41-49-53 32-42-49
HI-Poweriul) 1
Sound Pressure Level (Heating) (Lo-Med-Hi-Super dB(A)
Indoor Unit 28-33-38-43-48 32-41-49-52 32-41-49-52 34-42-49-49HI-Poweriul) 2
External Finish Color Munsell No 1 OY 9202
W In 31-716 43-516 46-116
Dimension Unit D In 9-18 9-38 11-58
H In 11-5 8 12-1316 14-38
Weight Unit Lbs 22 37 40
Field Drainpipe Size OD In 58
MCA A 14 171 21
MOCP A 15 20 25
Fan Motor FLA 093
Model (Type) DC INVERTER-driven Twin Rotary
Compressor RLA 100 129 16
LRA 125 161 20
Airilow CFM 1730 1659 17691 701 1941
Outdoor Unit Refrigerant Control Linear Ex~ansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(A) 54 55 56
Sound Pressure Level at Heating 2 dB(A) 56 55 57
External Finish Color Munsell No 3Y 7811
W In 33-116
Dimensions D In 13
H In 33-716 34-58 33-716
Weight Lbs 119 141
Remote Controller Type Wireless Remote (Optional Wired Controller)
Type R410A
Refrigerant Charge Lbs Oz 3 7 43 410
Oil Type (FI Oz) NE022 (152) FV50S (135) NE022 (29)
Gas Side OD 12 58In
Refrigerant Pipe Liquid Side OD 14 38
Height Difference (Max) 50
Length (Max) Ft
100 I Connection
Mpthon IndoorOutdoor Flared Flared
NOTESTest conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg C) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F (24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F(6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 17deg F(-8deg C) WB 15deg F(-9deg C) 4 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice LIMITED WARRANTY ISeven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 13
(SEZ-KD12NA MODEL SHOWN)
SEZ HEAT PUMP TAX
CREDIT
Model Name Indoor Unit SEZ-KD09NA4 SEZ-KD12NA4 SEZ-KD15NA4 SEZ-KD18NA4
Outdoor Unit SUZ-KA09NA SUZ-KA12NA SUZ-KA15NA SUZ-KA18NA Rated Capacity Btuh 8100 11500 14100 17200
Capacity Range Btuh 3800-10900 3800-13300 3800-17000 3800-19000
Cooling 1 Total Input W 670 920 1170 1380
Energy Efficiency SEER 15 16 155 175 Moisture Removal Pintsh 15 24 26 34 Sensible Heat Factor 080 076 080 079
Rated Capacity Btuh 10900 13600 18000 21600
Heating at 4YO F 2 Capacity Range Btuh 4800-14100 4800-16400 4800-21100 4800-24900
Total Input W 1020 1140 1500 1700 HSPF(lV) BtuhIW 100 Rated Capacity Btuh 6700 9000 11900 13100
Heating at 1 yo F 3 Rated Total Input W 810 920 1200 1350 Maximum Capacity Btuh 7300 9800 13700 15000
Power Supply Phase Cycle Voltage 1 Phase 60Hz 208 230V 4 Indoor - Outdoor S1 - S2 AC 208-230V
Voltage Indoor - Outdoor S2 - S3 DC 12-24V Indoor - Remote Controller See optional accessories chart (pg 26 and 27) MCA A 1 Fan Motor FLA 051 057 074
Airflow (Lo-Med-Hi) DRY (CFM) 194-247-317 247-317-388 353-441-529 423-529-635
WET (CFM) 174-222-285 222-285-349 317 -396-4 76 381-476-572 External Static Pressure 3 In wG 002-006-014-020 Sound Pressure Level dB(A) 23-26-30 23-28-33 30-34-37 30-34-38
Indoor Unit External Finish Galvanized-Steel Sheets
W In 31-18 39 46-78
Dimension Unit D In 27-916
H In 7-78
Weight Unit Lbs 42 50 54 62 Field Drainpipe Size 00 In 1-14
MCA A 12 14
MOCP A 15 Fan Motor FLA 050 093
Model DC Inverter DC Inverter Twin Rotary
I (Type)Compressor
RLA 66 74 10
LRA 82 93 125
Airflow (CoolingHeating) CFM 11511225 12291172 1 2431 229 17301659
Outdoor Unit Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(A) 46 49 54 Sound Pressure Level at Heating 2 dB(A) 50 51 56
External Finish Color Munsell No 3Y 7811
W In 31-12 33-16
Dimensions D In 11-14 13
H In 21-58 33-716
Weight Lbs 66 77 80 119 Remote Controller Type See optional accessories chart (pg 26 and 27)
Type R410A
Refrigerant Charge Lbs Oz 116 2 9
Type (fl Oil
oz) NE022 (108)
Refrigerant Pipe Gas Side OD In 38 Liquid Side 00 In 14
Refrigerant Pipe Height Difference (Max) Ft 40 Length Length (Max) Ft 65
Connection IndoorOutdoor FlaredFlared
Method
316
NE022 (152)
12
50
100
I
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg C) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F(8deg C) WB 43deg F(6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 17deg F(-8deg C) WB 15deg F(-9deg C) 4 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
14 MITSUBISHI ELECTRIC
SEZ STATIC PERFORMANCE CURVES (SEZ-KD12NA4 MODEL SHOWN)
SEZ-KD09NA4 SEZ-KD09NA4 (External static pressure O06[inwG]) 208230V 60Hz
[020] V L
5 [016
~l [0 12
]
SEZ-KD09NA4
~ ltij
~ [008
Jj
]
]
[004J ~
V V Middle
Low
V
19h
Rated point
1
o [141] [176J 1212) )247] [282J [318]
Airll ow rat e [CFM)
SEZ-KD12NA4 (External static pressure O06[inwG]) 208230V 60Hz
[020
5 [016
]
]
[353J
Limit
]
~ V
~ [ [0 12
u ltijJ[008
[004
]
_V ]~ Low
V
k-iddle
Rated POint
o [212) [247] [2 82] [318] [353] [388]
Airtlow rate [C FM]
SEZ-KD1SNA4 (External static pressure O06[inwGl) 208230V 60Hz
[424)
1020]
5 [016
~ ~ [012
~ ltij
~ [008
Jj
J
)
]
[004 ]
o
VV V [ Low
VV
vV High
Middle
I Rated point
[282] [318) [353] [388] [424] [459] [494] [530] [565J
Airllow rat e [CFM]
SEZ-KD18NA4 (External static pressure O06[inwG]) 208230V 60Hz
50 10 20]
] 40
5 [016
s 30 [ (012 )
ltij 20 ~ [008 )~Jj
10 [004]
V
Low
v Limit
rIV High
V [ Middle
~
1
Rated point
f318) [353) [388] [424] [459] [494] [530] [565] [600] [636] [671 )
Airllow rate [CFM]
(External static pressure O14[inwG]) 208230V 60Hz 80
[0 32
70 [028
5 60 [024
20 [0 08
10 [004
]
]
J
]
]
J
]V
]
U~it
V
k
High
~V Rated POI~1 V Middle Low
~
o [141] [1 76] 12121 )247J [282] [318]
Airtlow rate [CFM)
SEZ-KD12NA4 (External stat ic pressure O14[inwG]) 208230V 60Hz
[032]
[028J
5
[353]
J
~ [024
-~ [020] V-is
J V Il Hi9h Rated point
[016
~ ]
V V1 Middle
~ [012
[008]~
[004)
o [212)
[247)
SEZ-KD1SNA4
Low r
[282] [31 8) [353]
Airllow rale [CFM]
[388]
(External static pressure O14(inwG]) 208230V 60Hz
[032J
[424
]
2 V[028
5 [024]
V-i
] V High i [020
] K
Middle Rated point [0 16
g ]
~ -
QJj [0 12
J Low
[008
] I
~
[004
o [282J [318) [353J [388J [424) [459] [4 94] [530) [565)
Airt low rate [CFM]
SEZ-KD18NA4 (External statiC pressure O14(inwG]) 208230V 60Hz
1032
1028
~ 1024
-~ [0 20
is (0 16 ltij E ~ [012
(008
(004
o
I
]
]
)
]
)vlt ]
]
~ V
VV
Low
Limit
V
Ji9h
Middle l
Rated point
1 t
1
~ [318] [353] [388] [424] [459) [4 94] [530) [565) [600] [636] [671)
Airllow rate [CFM]
(External static pressure O20(inwG]) 208230V 60Hz
[032 ]
[028 J
5 [024
~ [020
is [016
1 [012Jj
[008
[004
J
]
]
] )
]
V Low
umz V High
~V
Rated point
Middle
1
[141] [176] [212) [247) [282) [318) [353J
Airtlow rat e [CFM]
SEZ-KD12NA4 (External static pressure O20(inwG]) 208230V 60H z
[032 ] LLimit
)
[0 28
5 ]
V
[024 -~ [020] V Rated point
Highis ~
) V
bull Middle
]~V I
[016
~ ~ [012
] Low
[008
]
[0 04
o [212) [247] [282] [318] [353] [388] [424]
Airllow rate [CFM]
SEZ-KD1SNA4 (External static pressure O20(inwG]) 208230V 60Hz
80 [032 ]
70 [0 28
~ [ O~~ -
ltij
E 30 ~ [0 12
20 [008
10 [004
o
)
J
]
]
JV
J
J
Limit V
LV High
V ~
K Rated point
Middle
VV 1gt
Low
I-
~ [282) [318) (353] (388) (424) 1459] [494] 15301 [565)
Airtlow rate [CFM]
SEZ-KD18NA4 (External static pressure O20[inwG]) 208230V 60Hz
[032
[028
~ [024sect
I [020
~ [016
~ Jj [0 12
[008
[004
o
]
)
]
]
]
~ )
]
]
1V
V 1
V
Low
1 limit
~~~ I ~~ High
~ R~ted pOini
Middle
1 1 -
[31 8) [353] [388] [424) [459] [494] [530] (565) [600] (636) [671J
Airllow rate [CFM)
Vl ~ ca (I)
I
N o ~ (I)
Vl m N Vl
-0 (I) n 3-i n QJ ~ o ~ tn
Note ESP 20S230V 60 Hz See manual for Static Performance Curve including 002 in WG
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts ~MITSUBISH[ ELECTRIC 15
SLZ HEAT PUMP (SLZ-KA12NA MODEL SHOWN)
Model Name Indoor Unit SLZ-KA09NA SLZ-KA12NA SLZ-KA15NA
Outdoor Unit SUZ-KA09NA SUZ-KA12NA SUZ-KA15NA Rated Capacity Btuh 8400 11100 15000
Capacity Range Btuh 3100-10900 3100-13300 3100-22200
Cooling 1 Total Input W 700 920 1460
Energy Efficiency SEER 15 154 16 Moisture Removal Pintsh 12 23 45 Sensible Heat Factor 080 076 080
Rated Capacity Btuh 10900 13 600 18000
Heating at 4r F 2 Capacity Range Btuh 3100-14100 3100-17100 3100-17100 Total Input W 930 1180 1950 HSPF (IV) BtuhIW 96 Rated Capacity Btuh 6200 8300 10200
Heating at 17deg F 3 Rated Total Input W 740 930 1310 Maximum Capacity Btuh 8300 10200 12000
Power Supply Phase Cycle Voltage 1 Phase 60Hz 208 230V 4 Indoor - Outdoor S1 - S2 AC 208-230V
Voltage Indoor - Outdoor S2 - S3 DC 12-24V
Indoor - Remote Controller See optional accessories chart (pg 26 and 27) MCA A 1 Fan Motor FLA 023 028 028
Airflow (Lo-Med-Hi) DRY (CFM) 280-320-350 280-320-390 280-320-390
WET (CFM) 250-290-320 250-290-350 250-290-350
Sound Pressure Level dB(Al 29-32-38 30-34-39 31-35-40
Indoor Unit External Finish Galvanized-Steel Sheets Grille Munsell 64Y 8904
W In 22-7 16 (25-58)
Dimension Unit (Grille) D In 22-716 (25-58
H In 8-316 (1316)
Weight Unit (Grille) Lbs 36 (7) Field Drainpipe Size 0 0 In 1-14 MCA A 12 MOCP A 15 Fan Motor FLA 050
Model (Type) DC INVERTER-driven DC INVERTER-driven
Compressor RLA 66
LRA 82
Airflow (CoolingHeating) CFM 11511225 1 229 1 172
Outdoor Unit Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(AJ 46 49 Sound Pressure Level at Heating 2 dB(AJ 50 51
External Finish Color Munsell No 3Y 781 1
W In 31 shy12
Dimensions 0 In 11-14
H In 21-58
Weight Lbs 66 77
~e R410A
Refrigerant Charge Lbs Oz 1 16
Oil Type (fl oz) NE022 108)
Refrigerant Pipe Gas Side 0 0 In 38 Liquid Side 00 In 14
Height Difference (Max) Ft 40 Refrigerant Pipe Length
Length (Max) Ft 65
Connection Method IndoorOutdoor FlaredFlared
29
Twin Rotary 74
93
12431 229
80
NE022 l152) 12
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg C) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F(8deg C) WB 43deg F(6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 17deg F(-8deg C) WB 15deg F(-9deg C) 4 Indoor units receive power from outdoor units through field-supplied interconnectedwiring Specifications are subject to change without notice
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
16 MITSUBISHI ELECTRIC
MHK1 WIRELESS REMOTE CONTROLLER KIT Exclusive for INVERTER-driven Mr Slimreg Systems VlWireless Technology a J
JMITSUBISHI ELECTRIC
Wireless Receiver
MHK1 Kit includes
09 mMRCH1 WIRELESS REMOTE CONTROLLER I Nbull Backlit easy-to-read display o
bull Dual setpoint control with system changeover J m
bull Enabled with RedLlNKTM reliability
bull Compatible with MCCH1 Vl Portable Central Controller m
N bull Installs Anywhere Vl
MFH1 WIRELESS RECEIVER N Vlbull Required for MRCH1 Wireless
CRemote Controller m bull Enabled with RedLiNK reliability n
31 n OJ o J en
SEZ and SLZ 11 systems with SUZ outdoor unit
Function Description
ONOFF OnOff operation for a single indoor unit
Operation Mode Cool I Drying I Auto I Heat I Fan only Available operation modes dependant on connected system
Temperature Setting Set temperature from 50degF - 8rF depending on operation mode and connected system
System Changeover Deadband Value 2-8degF
Schedule Operation 5-25-1-1
Fan Speed Setting HiMid-2Mid-1 IlowlAuto Available fan speed settings dependant on connected system
Air Flow Direction Setting Air flow angles 100deg - 80deg - 60deg - 40deg and oscilate Available air flow direction settings dependant on connected system
PermitProhibit Function Individual prohibit operations for each remote controller function (ONI OFF Set Temperature and Operation Mode)
Space Temperature Displays the measured space temperature
Error Indication Displays error code
Display Outside Temperature and Humidity
Requires optional MOS1 Outside Air Sensor
Dimensions - ryv x D x H) Remote Controller 5-316 x 1-12 x 3-916 Receiver 3-14 x 1-516 x 6-716
Operating Ambient Temperature Remote Controller 32 - 120degF Receiver -40 - 165degF
Operating Ambient Humidity Remote Controller 5 - 90 RH (non-condensing) Receiver 5 - 90 RH (non-condensing)
Power Supply 2 AA batteries
MRCH1 MIFH1 MRC1
Wireless Wall-Mounted Remote Controllers Wireless Receiver Cable
Accessories MCCH1 MOS1
Portable Central Controllers Outside Air Sensor
MITSUBISHI ELECTRIC 17
MULTIPLE ROOMS WITH INDIVIDUAL CONTROL FROM A SINGLE SYSTEM Enjoy ideal levels of comfort in the rooms you use most with our multi-room system Each room (zone) operates independently People in different rooms - the kitchen master bedroom or living room - can enjoy temperature settings that make each of them most comfortable
If you re looking for a complete comfort solution for several different rooms the MXZ multi-room system is the right choice The system is flexible enough to conform to a particular cooling and heating need and offers numerous different indoor unit combinations In addition up to eight indoor units can be connected to one outdoor unit Now with a SEZ horizontal ducted unit and a MFZ floorshystanding unit homeowners can enjoy an even greater range of zoning options provided by an MXZ system
An MXZ multi-room system is an excellent choice for supplementing capacity to a current system conditioning newly furnished spaces or new additions and replacing a system within a home Homeowners can also benefit from lower energy costs year-round while staying comfortable thanks to Mitsubishi Electrics energy-efficient technologies that are a part of every system that we make
To add to the level of energy efficiency the MXZ -2B20NA and MXZ -3B24NA systems qualify for both ENERGY STARreg and the federal tax credit (See details on page 21 for applicable indoor unit combinations)
At right a single level home with several system types represented (For illustrative purposes only)
MFZ Floor-Standing Indoor Units for MXZ Heat Pump Systems
Floor-standing indoor unit mounts three inches above the floor and has front panel access to the filter for ease of cleaning
The MFZ units provide energy-efficient solutions to provide personalized comfort for difficult areas that may be smaller or dont have usable space on the walls
MFZ units on MXZ systems include the following features bull Top and bottom discharge vanes bull Hot-start technology bull Quiet operation bull Wireless remote control (optional wall-mounted controller)
18 MITSUBISHI ELECTRIC
MSZ Wall-Mounted Indoor Units for MXZ Heat Pump Systems
Providing a wide range of cooling and heating capacities each wall-mounted indoor unit mounts high on a wall and connects to a branch box or the outdoor unit by a refrigerant line run via a 3 hole The MSZ units provide highly efficient solutions to cooling and heating needs and provide personalized comfort for the individual zones in which they are installed
MSZ units on MXZ systems include the following features bull Sleek flat panel design bull Hot-start technology bull Quiet operation bull i-seeM sensor technology (MSZ-FE0912NA models only) bull Enhanced filtration system (MSZ-FE0912NA models only) bull Wireless remote control (optional wired wall-mounted controller)
SLZ Ceiling-Recessed Indoor Units for MXZ Heat Pump Systems
The new SLZ-KA ceiling casette systems offer a wide air-flow pattern for better air distribution
offered to your customers Installation can be done in a hard ceiling (with a access panel for servicing) or placed into a 2x2 drop ceiling With a built-in drain lift mechanism for condensate
removal and a 4 ventilation air intake knockout option the SLZ is ready to handle a variety of installation needs
SLZ units on MXZ systems include the following features bull Wide air-flow pattern for better air distibution bull 4 ventillation air intake knockout bull Built-in condensate lift mechanism bull Wireless RedLlNKTM remote controller
SEZ Horizontal Ducted Indoor Units for MXZ Heat Pump Systems
SEZ ducted units can provide split air-conditioning system advantages with the added benefit of being concealed to provide virtually no visual footprint within the conditioned space other than a register and grille for the air to flow With the use of short run ductwork these units can provide comfort to a single room that needs air dispersed evenly throughout the space unusually shaped rooms and adjacent rooms
The SEZ unit on MXZ systems include the fOllvowin fatures _
g~e~~~~==Zl[bull Concealed design for short-run ductwork bull Quiet operation bull Built-in condensate lift mechanism
JMITSUBISHI ELECTRIC 19
s c t
I
N o J ro o ltro ~ ro ~
DIAMOND COMFORT MXZ MULTI-ZONE SYSTEMS MXZ-B Series multi-zone systems provide personalized comfort control and energy efficiency in up to eight rooms with only a single outdoor unit The MXZ-B Series system features include
bull Individual zone control bull Mix and match flexibility of indoor unit styles and combinations bull A wide range of indoor unit capacities that match the room size and requirements bull Flexible design options to tackle the most challenging multi-room installations bull Efficient systems including three systems [mxz series] that meet energy starltID and
federal tax credit requirements bull Simple quick and cost-effective installation keeps install costs down on new construction
and disruption to a minimum on renovations and refits
Efficiency and performance ratings depend on the number style and capacity of the indoor units installed with each Multi-Zone System
MXZ -2 B20 NA - 1 (2 1 ) MXZ -3 B24 NA (2 13 1) Ou tdoo r Unit Outdoor Uni t
MSZ-GE09NA Indoor Units
SEZ-KD12NA Indoor Unit
MSZ- GE06NA
~~~~li
(At least two indoor units MSZ-GE06NAIndoor Unit must be installed) Indoor Unit
(Two indoor units must be installed )
MXZ -3 B30 NA (2 1 3 1) Outdoor Unit
SEZ-KD12NA Indoor Unit
~~~i
(At least two indoor units MSZ-GE06NA must be installed)
Indoor Unit ~
MFZ- KD12NA Indoor Unit
MXZ-8B48NA (2 1-8 1) Outdoor Unit
(At least two indoor units
must be installed)
(At least two indoor units must be installed)
MFZ-KD09NA Indoor Units
MSZ-GE09NA Indoor Units
SEZ-KD12NA Indoor Unit
MSZ INDOOR UNIT
MSZ-FE18NA
PEAD HORIZONTAL -DUCTED INDOOR UNIT
PEAD-A24AA
MSZ INDOOR UNIT SEZ HORIZONTAL-DUCTED MSZ-FE18NA
INDOOR UNIT MFZ FLOOR-STANDING SEZ-KD18NA INDOOR UNIT
MFZ-KA12NA
20 AMITSUBISHI ELECTRIC
MULTI-ROOM MXZ-8 INVERTER HEAT PUMP R
Model Name Outdoor Unit MXZ-2B20NA-1 5 MXZ-3B24NA 6 MXZ-3B30NA MXZ-4B36NA 7
Indoor Unit
Cooling 1 Non-ductedl Ducted
Rated Capacity Btuh 1800020000 2200023600 28400127400 3540034400
Capacity Range Btuh 7800-20000 12600-25500 12600-28400 12600-36400
Total Input W 2190 (630-219QL 2460 (1000-2950) 3330 l1 000-3330) 3 940 (1 000-4020)
Heating at 4JO F 2 Non-ductedl Ducted
Rated Capacity Btuh 2200022000 2500024600 2860027600 3600034400
Capacity Range Btuh 8500-25500 11400-30600 11 400-36000 11400-43000
Total Input W 2620 (520-2620) 1900 (740-2600) 2220 (740-2820) 3100 (740-3940)
Heating at 1JO F 3 Non-ductedl Ducted
Rated Capacity Btuh 1250012500 1400014000 1600015100 2220020300
Rated Total Input W 13501430 13801570 21202 140 24302340
Maximum Capacity Btu h 1450014500 1880017000 1880018000 2460025400
Maximum Total Inl2ut W 15001590 21202230 21202140 33403450
Power Supply Phase Cycle Voltage 1-phase 60Hz 2081 230V 8
Voltage Indoor shy Outdoor S1 - S2 AC 2081 230V
Indoor shy Outdoor S2 - S3 DC12-24V
Outdoor Unit 4
MCA A 15 19
MOCP A 20
Fan Motor FLA 096 093
Compressor
Model (Type)
DC INVERTER-driven Twin Rotary
RLA 101 11 144
LRA 15
Airflow (CoolingHeating) CFM 14851 640 20681605 13651605 20682068
Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1
dB(A) 49 54 49 54
Sound Pressure Level at Heating 2
dB(A) 51 49 57
External Finish Color Munsell No 30Y 781 1
Dimensions
W In 33-116 35-716
D In 13 12-58
H In 27-1516 35-7116
Weight Lbs 130 150 153
Indoor Unit No of Units 2 23 23 234
Remote Controller Type Associated with the Indoor Unit
Refrigerant
Type R410A
Charge Lbs Oz 515 7 11 813
Oil Type (fl oz)
NE022 (237) NE022 (294)
Refrigerant Pipe Gas Side 00 In AB 38 A 12 BC 38 A 12 BCD 38
Liquid Side 00 In 14
Refrigerant Pipe Length Height Difference (Max) Ft 4933 9
Length (Max) Ft 164 (A+B) 230 (A+B+C) 230 (A+B+C+D)
Connection Method IndoorOutdoor FlaredlFlared
Compatible with the MSZ-A MSZ-GA MSZ-FD MSZ-FE MSZ-GE MFZ-KA and SEZ-KD series indoor units (PLA-18 amp PCA-24 on the MXZ-MXZ-3B PLA-24 amp PCA-24 on the MXZ-4B)
NOTES Test conditions are based on AHRI 210240 One indoor unit is turned off during low-speed testing under the new test conditions Systems actually exhibit higher energy efficiencies during normal operation
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F (35deg C) WB 75deg F (24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F (6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 600 F (160 C) Outdoor DB 17deg F (_80 C) WB 150 F (_90 C) 4 Refer to pages 12 and 13 for Indoor Unit specifications 5 Data from combination of two Indoor Units 9000 Btuh (non-ducted) or one 9000 Btuh and one 12000 Btuh (ducted) 6 Data from combination of two Indoor Units 6000 Btuh and one 9000 Btuh (non-ducted) or three 9000 Btuh (ducted) 7 Data from combination of four Indoor Units 9000 Btuh (non-ducted and ducted) 8 Indoor units receive power from outdoor units through field-supplied interconnected wiring 9 49 Applies to installations where the outdoor unit is installed below the indoor unit
Power factor equals 97 percent
Specifications are subject to change without notice
MULTI-ZONE ENERGY STAR AND TAX CREDIT SYSTEMS
Model Indoor Unit Combinations SEER HSPF
MXZ-2B20NA-1 2 x MSZ- GE09NA 18 8 9
MXZ- 3B24NA 2 x MSZ- GE06NA 1 x MSZshy GE09NA
17 5 9 3
MXZ- 3B24NA 2 x MSZ-GE06NA 1 x MSZ- GE12NA
17 5 93
For more details on all ENERGY STAR and tax credit systems go to wwwmitsubishicomfortcomtaxcredit
See page 25 for additional info on efficiency
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 21
MXZ-8B48NA THE ULTIMATE ZONING SOLUTION
The Mitsubishi Electric MXZ-S84SNA eight-zone unit As a member of the expanding MXZ-B Series of multi-zone systems the MXZ-8B outdoor unit incorporates branch boxes to connect up to eight indoor units MXZ- 8 B48 NA (2 1 - 8 1 )
Outd oor Uni t The INVERTER-driven compressor at the heart of the MXZ-8B -~-- shy
outdoor unit provides variable capacity control allowing the system to adjust to the specific demands of the interior space ~ as needed not the hard start and stop of a traditional system I[iDA Jinstalled in most US homes
The MXZ -8B48NA has only one port on the outdoor unit for two insulated refrigerant lines which run into the home or business to connect to a branch box or boxes From the branch box(es) gas and liquid refrigerant piping run to each of the indoor units The LEV in the branch box(es) controls the refrigerant flow as the load of each zone changes
Through the branch box(es) (the PAC-AKA31 BC three-port andor the PAC-AKA51 BC five-port) the system can connect from two indoor units up to eight indoor units depending on application requirements
The flexibility of the system doesnt stop there The MXZ-8B48NA has rated capacities of 48000 Btuh for cooling and 54000 Btuh for heating System operation however can range from a minimum 12000 Btuh to a maximum 54000 Btuh in cooling and a maximum of 60000 Btuh in heating This type of performance supports a large variety of applications
The MXZ-8B48NA allows for further flexibility because it supports a connected indoor unit capacity from 22 to 130 or 12000 Btuh to a maximum 70200 Btuh depending on diversity
Connectable Indoor Units General Features bull Four-ton outdoor unit can support up to
eight indoor units using branch boxes bull Wide variety of indoor unit styles
-=--_-=-----= - - J _ 1
including wall-mounted floor-standing MSZ-FE09 12 18NA MSZ-GE06 09 12 15 18 24NA ceiling-cassette ducted
bull Individual control up to eight (8) zones using wired or wireless controls
bull Advanced microprocessor control bull Auto restart following a power outage bull Self-check function offering SEZ-KD09 1215 18NA PEAD-A24AA
integrated diagnostics ~--- Jbull Limited warranty five years on parts and
defects and seven years on compressors
SLZ-KA09 1215NA MFZ-KA09 12 18NA
22 MITSUBISHI ELECTRIC LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
I
RMULTI-ROOM MXZ-8 INVERTER HEAT PUMP
Model Name Outdoor Unit MXZ-BB4BNA Cooling 1 Rated Capacity
Non-ducted Rated Total Input Ducted
Maximum Capacity
Rated CapacityHeating at
Rated Total InputIndoor Unit 4JO F 2 Non-
ductedDucted Maximum Capacity
Rated Capacity Heating at
Rated Total InputlJO F 3 Non-ductedDucted Maximum Capacity
Power Supply Phase Cycle Voltage
Indoor - Outdoor Sl - S2 Voltage
Indoor - Outdoor S2 - S3
MCA
Recommended FuseBreaker Size
Fan Motor
Compressor
Airflow (CoolingHeating)
Refrigerant Control
Outdoor Unit Sound Pressure Level at Cooling 1
Sound Pressure Level at Heating 2
External Finish Color
Dimensions
Weight
Total Capacity 22-130
Indoor Unit ModelQuantity
Remote Controller Type
Type
Refrigerant Charge
Oil
Gas Side OD Refrigerant Pipe
Liquid Side OD
Height Difference (Max)
Maximum Distance between (Outdoor unit and farthest indoor unit)
Refrigerant Pipe Length Maximum Pipe Length -Branch box to Indoor Unit
Total Maximum line length between Branch Box and All Connected Indoor Units
Total Length (Max)
Connection Method IndoorOutdoor
Includes both branch boxes if there are two
Branch Boxes (At least one branch box required)
Btuh
W
Btuh
Btuh
W
Btuh
Btuh
W
Btuh
A
A
Type x Quantity
Motor Output (kW)
Model (Type)
Motor Output (kW)
CFM
dB(A)
dB(A)
W In
D In
H In
Lbs
Btuh
Lbs Oz
Type (fl oz)
In
In
Ft
Ft
Ft
Ft
Ft
4800048000
57806470
54000
5400054000
48205270
60000
3300034700
29503390
3660036550
1 Phase 60Hz 208 230V
AC 208-230V
DC12-24V
32
40
Propeller x 2
0086 + 0086
DC INVERTER-driven Scroll
29
3530
Linear Expansion Valve
54
55
Munsell No 3Y 78 11
37-716
13+1-3 16
53-3 16
278
12000 - 70200
600 - 24000 2-8
Associated with Indoor Unit Model
R410A
18 112
FV50S (73)
58
38
6698 4
230
49
197
377
FlaredFlared
Compatible with the MSZ-A MSZ-FO MSZ-FE MSZ-GE MFZ-KA SEZ-KD PLA and PEAD series indoor units
NOTES Test conditions are based on AHRI 210240 One indoor unit is turned off during low-speed testing under the new test conditions Systems actually exhibit higher energy efficiencies during normal operation
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F (35deg C) WB 75deg F (24deg C)
2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 4]0 F (8deg C) WB 43deg F (6deg C)
3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 17deg F (-8deg C) WB 15deg F(-9deg C)
4 66 applies to installations when the outdoor unit is installed below the indoor unit
Power factor equals 97 percent
Specifications are subject to change without notice
Note Maximum installed capacity is the maximum total of all connected indoor units NOT the maximum capacity produced
Only a single Lineset is needed from the outdoor unit to branch box
See page 25 for MXZ-B information on efficiency
Required Branch Boxes for MXZ-SB4BNA (Maximum of 2 branch boxes can be connected to one outdoor unit requires joint MSDD-50AR-E or MSDD-50BR-E)
s c d N o J ro Vl
0 ro n 3i n OJ d o J U)
PAC-AKA51 BC Branch Box
PAC-AKA31 BC Branch Box LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 23
MSZ WALL-MOUNTED INDOOR UNITS (FOR MXZ-8 OUTDOOR UNITS)
R
(MSZ-GE12NA MODEL SHOWN)
-000 IIIIIII 9000 9000 12000 12000 14000 17200
Heating at 4r Rated Capacity Btuh 7200 10900 10900 14400 13600 18000 21600
F2 Power Supply I Phase Cycle Voltage J -phase 60Hz 208 230V 3
Iindoor Outdoor S1 S2 AC 208 230V
Iindoor Outdoor S2 S3 DC12-24V Voltage
Iindoor Remote vomr Iller Wireless Type (Optional Wired vomroller DC 12V)
IMCA A 10 IFan Motor FLA 076
DRY 162-226shy145-170shy
162-226shy205-272shy 230-275shy
Airflow at Cooling (CFM)
145-170-237-321-399 339-381
237 -321shy381-410
335-420shy 339-420shy(Quiet-Lo-Med-Hishy 399 533 533 Super Hi or Lo-Med-
WET 144-202shy109-134shy
144-202shy170-237shy 194-240shy
Fan Hi-Powerful)1 (CFM)
109-134-201-286-364 307-343
201-286shy350-367
300-385shy 304-385shy364 498 498
Airflow at Heating 145-170shy 145-170shy 145-170shy 205-247shy 230-275shy
(Quiet-Lo-Med-Hi- WET 233-321shy 237-321shy
166-240shy237-321shy
166-240shy304-367shy 339-431shy
Super Hi or Lo-Medshy (CFM) 406 406
367 -381 406
399-420 463 512
Hi-Powerful) 2 Sound Pressure Level at Cooling
19-22-30shy 26-32-38shy 28-33-38shy(Quiet-Lo-Med-Hi-Super Hi or Loshy dB(A) 19-22-30-37 -43 22-31-39-42
37-45 22-33-43-45
44-49 44-49Med-Hi-Powerful) 1
Sound Pressure Level at Heating 19-22-30shy 26-30-35shy 28-33-38shy
(Quiet-Lo-Med-Hi-Super Hi or Loshy dB(A) 19-22-30-37 -43 22-31-40-42 37-43
22-23-43-44 40-46 43-48
Med-Hi-Powerful) 2
I External Finish Color Munsell No 10Y 92 02
IWln 31 middot716
Dimension Unit 10 In 9 18 10-18 9middot18 10-18 9-18
IH In 11-58
I Weight Unit ILbs 22 27 22 27 22 I Field Drainpipe ~D lin 58 Remote Con-
Type Wireless Remote (Optional Wired Controller) troller
ITvpe B41QA Refrigerant ~s$ideOD lin 38 Pipe I Liquid Side 00 In 14
Connection IndoorOutdoor FlaredFlared
Method
1~
II 18000 22500
21600 27600
388-469shy 38$-469shy628-738 628-738
347-420shy 347-420shy562-661 562-661
388-469shy 388-469shy628-738 628-738
34-41-49-53 34-41-49-53
32-41-49-52 32-41-49-52
43-516
9-38
12-1316 37
58 38
MXZ-2B20NA is also compatible with the MSZ-A and MSZ-FD series indoor units NOTES Test conditions are based on AHRI 210240
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F(6deg C) 3 Indoor units receive power from outdoor units through field-supplied wiring
Specifications are subject to change without notice LIMITED WARRANTY Seven-year warranty on compressor Five-year warranty on parts For data on specific indoor unit combinations see page 21
SEZ DUCTED INDOOR UNIT (FOR MXZ-8 OUTDOOR UNITS)
I
Notes 1 Cooling-Indoor DS 80deg F(267deg C) WS 67deg F(194deg C) Outdoor DS 95deg F (35deg C) WS 75deg F(239deg C)
2 Heating-Indoor DS 70deg F(211 deg C) WS 60deg F(156deg C) Outdoor DS 47deg F (83deg C) WS 43deg F(61 deg C)
3 External static pressure is factory set to 006 WGAdjustable via the
1---------t---+-----L-------------1~---__I PAR-21MAA
1--_____----__________+-____---L____----~_____________1 4 Indoor units receive power
jE~~~~-------------r----1-----~-~~~~~~~~-----___1 from outdoor units through fieldsupplied interconnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven-year warranty on compressor Five-year
1---------------------+---+------------------------1 warranty on parts
~--__I_~----------+-------~l----------I For data on specific indoor unit combinations see page 21 - 23
I--~------+~-----------~----------r_------------I
- Reference page 17 for SEZ static performance curves
24 MITSUBISHI ELECTRIC
25-30-35-40 26-31-36-41 35-38-42-46
25-30-35-40 28-31-36-41 35-38-42-47
MFZ FLOORLOW WALL INDOOR UNIT (FOR middotMXZ-8 OUTDOOR UNITS)
------shy
-==
Airflow at Heating (CFM) 177-198-219-332 184-201-219-335 261-275-297-434
Voltage
Fan
Airflow at Cooling (Lo-Med-Hi-Super Hi)1
169-205-251-314 251-279-325-394
163-197-241-303 170-207-252-309 241-269-313-379
(Lo-Med-Hi-Super Hi) 2
SLZ CEILING-RECESSED INDOOR UNIT (FOR MXZ-8 OUTDOOR UNITS) EFFICIENCY RATINGS
Voltage
Fan
Galvanized-steel SheetsMunsell 64Y 89 04
Refrigerant Pipe
Model Indoor Unit Type SEER HSPF
MXZ-2B20NA-1
Non-dueted 18 89
Dueted and Non-dueted 1675 87
Dueted 155 85
MXZ-2B20NA-1 ENERGY STAR amp
TAX CREDIT 2 x MSZ-GE09NA 18 89
MXZ-3B24NA
lJon-dueted 175 93
Dueted and Non-dueted 1625 89
Dueted 150 85
MXZ-3B24NA ENERGY STAR amp
TAX CREDIT
2 x MSZ-GE06NA 1 x MSZ-GE09NA
175 93
MXZ-3B24NA ENERGY STAR amp
TAX CREDIT
2 x MSZ-GE06NA 1 x MSZ-GE12NA
175 93
MXZ-3B30NA
Non-dueted 175 105
Dueted and Non-dueted 16 100
Dueted 145 95
MXZ-4B36NA
Non-dueted 18 93
Dueted and Non-dueted 16 5 92
Dueted 150 9 0
MXZ-BB4BNA
Non-dueted 15 87
Dueted and Non-dueted 14B B8
Dueted 147 89
Connection IndoorOutdoor FlaredFlared
Method
Notes 1 Cooling-Indoor DB 80deg F(267deg C) WB 67deg F(194deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(239deg C) 2 Heating-Indoor DB 70deg F(21 1 deg C) WB 60deg F(156deg C) Outdoor DB 47deg F(83deg C) WB 43deg F(61 deg C) 3 Indoor units receive power from outdoor units through field supplied interconnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 25
Notes 1 Cooling-Indoor DB 80deg F(267deg C) WB 67deg F (194deg C) Outdoor DB 95deg F (35deg C)WB 75deg F (239deg C)
2 Heating-Indoor DB 70deg F(211deg C) WB 60deg F (156deg C) Outdoor DB 47 F (83deg C) WB 43deg F (61 deg C)
3 Indoor units receive power from outdoor units through field supplied interco(lnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven -year warranty on compressor Five-year warranty on parts
Presently there is no 1 1 system with the MFZ indoor unit
s c
N o J ro Vl
C ro n ~ n OJ t o J V)
M-SERIES RATING CONDITIONS
INDOOR INTAKE AIR TEMPERATURE
OUTDOOR INTAKE AIR TEMPERATURE
COOLING
MAXIMUM
95degF DB 71 degF WB (MU SUZ MXZ-2B20-13B243B304B36) 90degF DB 73degF WB (MUZY-GE MUZ-FE MUzy-D)
115degF DB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B24 3B304B368B48)
MINIMUM 67degF DB 57degF WB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B201 3B243B304B36)
14degF DB (MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B24 3B304B36) 23degF DB (MXZ-8B48) 6rF DB (MU)
MAXIMUM 80degF DB 6rF WB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B243B304B36)
75degF DB 65degF WB (MUZY-GE MUZY-GA24 MUZ-FE SUZ MXZ-2B20-1 3B243B304B36) 70degF DB (MXZ-8B48)
HEATING
MINIMUM 70degF DB 60degFWB (MUZ-GE MUZ-GA24 MUZ-D MUZ-FE SUZ MXZ-2B20-1 3B243B304B36)
-13degF DB -15degFWB (MUZ-FE) -4degF DB -5degF WB (SUZ MUZ-GE) 5degF DB 4degF WB (MUZ-GA24 MXZ-8B48NA) 6degF DB 5degF WB (MXZ-2B20-1 3B24 3B304B36) 14degF DB 13degFWB (MUZ-D)
MU units operate at intake air temperature down to 10deg Fwith the addition of an ICM-326HM-1 low temperature control
REFRIGERANT TUBING SETS
OPTIONAL ACCESSORIES
REFRIGERANT LINE LENGTH FLARE FLARE _INDOOR UNIT OUTDOOR UNIT
MS-A09WA MU-A09WA 35 MS-A12WA
65 MU-A12WA 35
MSY-GE09NA 65
MUY-GE09NA 40
MSY-GE12NA
65
MUY-GE12NA 65 40
MSY-GE15NA MUY-GE15NA 40
MSY-GE18NA
65
MUY-GE18NA 100 50
MSZ-GE09NA MUZ-GE09NA 65 40
MSZ-GE12NA MUZ-GE12NA 40
MSZ-GE15NA
65
MUZ-GE15NA 40
MSZ-GE18NA
65
MUZ-GE18NA 100 50
MSY-GE24NA MUY-GE24NA 100 50
MSZ-GE24NA MUZ-GE24NA 100 50
MSY-D30NA MUY-D30NA 100 50
MSZ-D30NA MUZ-D30NA 50
MSY-D36NA
100
MUY-D36NA 50
MSZ-D36NA
100
MUZ-D36NA 100 50
MSZ-FE09NA MUZ-FE09NA 40
MSZ-FE12NA
65
MUZ-FE12NA 40
MSZ-GE06091215NA MSZ-FE0912NA
65
MXZ-2B20NA-1 164 4933MFZ-KA0912NA SEZ-KD09 1215NA
MSZ-GE0609 121518NA MSZ-FE091218N MFZ-KA09 1218NA MXZ-3B24NA 164 4933 SEZ -KD09 12 15 18NA SLZ-KA09 12 15NA
MSZ-GE0609 121518NA MSZ-GA24NA MSZ-FE091218NA
MXZ-3B30NA 4933230MFZ-KA091218NA SEZ -KD09 121518NA SLZ-KA09 12 15NA
MSZ-GE0609121518NA MSZ-GE24NA MSZ-FE09 12 18NA
MXZ-4B36NA 230 4933MFZ-KA091218NA SEZ -KD09121518NA SLZ-KA09 12 15NA
MSZ-GE0609 12 15 18NA MSZ-GE24NA MSZ-FE09 12 18NA
MXZ-8B48NA 6698377MFZ-KA091218NA SEZ-KD09121518NA SLZ-KA09 12 15NA
PART NUMBER I USE WITH I DESCRIPTION
Port Adapters and Connection Pipes MAC-A454JP-E MXZ-Series Adapter 38 X12
MAC-A455JP-E MXZ-Series Adapter 12 X38
MAC-A456JP-E MXZ-Series Adapter 12 X58
MSDD-50AR-E MXZ-Series Branch Box Tee Distribution Pipe - Flare Connection between two branch boxes
MSDD-50BR-E MXZ-Series Branch Box Tee Distribution Pipe - Braze Connection between two branch boxes
PAC-493PI MXZ-Series Adapter 14 X38
PAC-SG76RJ-E MXZ-Series Adapter 38 X58
OPTIONAL ACCESSORIES CONTINUED ON NEXT PAGE
49 amp 66 applies to installations in which the outdoor unit is installed below indoor unit26 MITSUBISHI ELECTRIC
OPTIONAL ACCESSORIES (CONTINUED)
PART NUMBER USE WITH DESCRIPTION Control Options and Accessories
M21 JKO 307 M-Series Indoor Units Remote temperature sensor for M-Series indoor units
MAC-397IF-E
MAC-399IF-E
PAC-YU25HT
PAR-21 MM-G
M-Series INVERTER Units
M-Series INVERTER Units
SEZ-KD Indoor Units
Use with P-Series SEZ and for wired M-Series Controller
MA and contact terminal interface - Required to use PAR-21 MM wired wall mount controller with M-Series Systems
CMCN M-NET control adapter I Interface for Mr Slim M-Series MSYZ SEZ I MFZ
External Fan I Heater control relay adapter
Deluxe MA remote controller (Requires MAC-397IF-E for use with M-Series - MSYZ MFZ)
SEZ Wireless remote controller for SEZ units (Requires signal receiver PAR-SA9FA-E)PAR-FL32MA
PAR-SA9CA-E SEZ Wireless signal receiver for SEZ
3-pole disconnect switch 30A 600V turns off power between indoor and outdoor units shyM-SeriesTAZ-MS303
mounts in 2 X 4 utility box and requires standard single gang switch platecover - Low Ambient
ICM-326HM-2 M-Series Non-INVERTER units Low ambient head pressure controller MUZ-GE091215 IVIUZ-FE0912 SUZ-KD091215
Drain pan heaterMAC-640BH-U outdoor unit
MAC-641 BH-U MUZ-GE18 SUZ-KD18 outdoor unit Drain pan heater Filters
MAC-1415FT-E Anti-allergy enzyme filter
MAC-2300FT
MSZlMSY-D3036
Anti -allergy enzyme filter
MAC-308FT
MSYMSZ-GA24
MSZ-FD912 I FE0912 Platinum deodorizing filter
MAC-408FT-E Anti-allergy enzyme filter
MAC-415FT-E
M-Series Indoor Unit - GE09GE12GE15GE18
MFZ-KA Air Cleaning FilterAnti-Aliergy Enzyme Filter
MAC-418FT Anti-allergy enzyme filter
Filter Boxes
FBL1-1
MSZ- FD912 I FE091 2
FB Series Filter Box for SEZ-KD09NA Optional filter box with MERV 8 filters
FB Series Filter Box for SEZ-KD1215NAFBL1-2 Optional filter box with MERV 8 filters
and PEA-A 12M
FBL1-3 FB Series Filter Box for SEZ-KD18NA Optional filter box with MERV 8 filters
Pumps
SI1730-230 MSYZ - 30000 Btuh or greater Sauermann mini condensation pump 230V
S13100-115 MS-Series - non-INVERTER Sauermann mini condensation pump 115V
S13100-230 Sauermann mini condensation pump 230VMSYZ - Less than 30000 Btuh
Miscellaneous BRP-1 Bottom Return Plate for SEZ-KD09NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-2 Bottom Return Plate for SEZ-KD12KD15-NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-3 Bottom Return Plate for SEZ-KD18NA Converts low profile ducted indoor unit from rear return to bottom return
BV12FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderreglnsulated - 12
BV14FSI Use with any Mr Sl im multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 14
BV38FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 38
BV58FSI Use with any IVIr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 58
Condensing unit wall mounting brackets (set of 2) - 440 lb capacity painted steel NOTE CWMB1 IVIU and PU outdoor units Installer is responsible to select and provide suitable hardware and materials to insure proper
mount of bracket to wall
DSD-400N M-Series DiamondBacktrade Platform Stands MUZ-GE18 I MUZ(y)-03036 I
MAC-811DS Drain socket assemblySUZ-KA18
MAC-851DS MUZ-FD0912 Drain socket
MAC-855SG M-Series Air outlet guide
MAC-856SG M-Series Air outlet guide - MXZ-3B24 I 3B30 I 4B36 NA
MAC-860DS MUZ-GE091215 I MUZ-FE0912 Drain socket
MAC-889SG M-Series Air outlet guide- MXZ-2B20NA
MAC-S99SG M-Series Air outlet guide
PAC-SG59SG-E IVIXZ-SB4SNA Air outlet guide (1 piece) I MXZ-SB48NA (Requires 2 pieces)
PAC-SG61 DS-E MXZ-8B4SNA Drain socket - connector
PAC-SG64DP-E MXZ-SB48NA Drain pan
RCMKP1CB lVI-Series Wireless Lockdown bracket for remote controller
lILTRILlTE1 All M-Series Condensing unit mounting pad 16 x 36 x 3
MITSUBISHI ELECTRIC 27
MXZ-8 Series Port Adapter chart Port Adapter Unit Port
Combinations Required Size
MXZ-2B20NA-1
2-zone combinations wi NA
A 38 x both units s12K 14
1-MAC-A454JP-E B 38 x
6+15 14
9+15 1-MAC-A454JP-E
MXZ-3B24NA
All rated 2-zone combina-NA
A 12 x tions 14
All rated 3-zone combina-NA
B 38 x tions 14
C 38 x 14
MXZ-3B30NA
2-zone combinations wi at NA
A 12 x least one unit s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
9 + 24 14
3-zone combinations wi 1-MAC-A455JP-E
all units s12K
All other rated 3-zone NA
comb
MXZ-4B36NA
2-zone combinations wi at NA
A 12 x least one un it s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
6 + 24 14
1-MAC-A456JP-E D 38 x
9 + 24 14
3-zone combinations wi at NA
least two units s12K
3-zone combinations wi 1-MAC-A454JP-E
two units15K
6+6+24 or 6+9+24 1-MAC-A456JP-E
9+9+24 1-MAC-A456JP-E
4-zone combinations wi at 1-MAC-A455JP-E
least three units s12K
6+6+15+15 1-MAC-A454JP-E
6+6+15+15 1-MAC-A454JP-E
Note When using the Pu-A24BA PCA-A24KA or PEAD-A24AA two port adapter will be needed 1-MAC-A456JP-E (12 x 58) A port or 1-PACshySG76RJ-E (38 x 58) B C and D ports and 1-PAC493PI (14 x 38)
28 JMITSUBISHI ELECTRIC
6+6+246+9+24 6+12+249+9+24 9+12+24 or 12+12+24
6+15+24 6+18+24 9+15+249+18+24 12+15+24 or 12+18+24
15+15+24 15+18+24 or 18+18+24
15+24+24 or 18+24+24
Combinations of 4 or more zones
1-PAC-SG76RJ-E
See notes for application below
2
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
See notes for application below
PORT A =38 gas x 14 liquid
PORT B =38 gas x 14 liquid
PORT C =38 gas x 14 liquid
PORT A =38 gas x 14 liquid
PORT B = 38 gas x 14 liquid
PORT C = 38 gas x 14 liquid
PORT D =38 gas x 14 liquid
PORT E =12 gas x 14 liquid
Notes for application bull Check the lineset sizes for your indoor selected models bull Select the branch box or boxes needed for your application bull Compare indoor unit lineset sizes as compared to branch
box sizes bull Connect 15K + indoor units to the larger port on the
(PAC-AKA51 BC) bull Adapt lineset size with appropriate port adapter from
above list bull When using the PU-A24BA or PEAD-A24AA two port
adapter will be needed 1-MAC-A456JP-E (12 x 58) or 1-PAC-SG76RJ-E (38 x 58) and 1-PAC493PI (14 x 38)
-fv
~ DIAMONDBACKtrade
~) BV-Series Ball Valves Model numbers
BV14FFSI BV38FFSI
LISTED 891N REFRIGERANT
BV12FFSI VALVE bull Engineered for Mini-split andBV58FFSI
Multi-split HVAC Units bull Size available 14 38 12 58
bull Full Port Designbull Fully factory assembled bull Furnace brazed and pressure tested bull 700 PSIG Rated bull Each ball valve is equipped with Schraderreg Valve
for refrigerant service bull R-410A Compatible bull Design working pressure 700 PSIG bull Temperature range bull Flare Connections
-40 0 F to +3250 F (-400 C to + 1490
C) bull Forged brass body and seal cap bull Teflonreg seals and gaskets (no synthetic a-rings) bull Seal cap design permits valve operation without
removal of seal cap bull Suitable for use with R-11 R-22 R-123 R-125
R-134A R-236FA R-4202A R-402B R-404A R-407C R-410A R-500 R-502 and R-507
bull One year limited materials and workmanship
Part Number SAE Flare
A B C 0 E F
BV14FFSI 14 619 260 180 122 142 110
BV38FFSI 38 630 267 180 122 142 110
BV12FFSI 12 651 267 180 122 142 110
BV58FFSI 58 664 267 180 128 142 110
Ball valves come With an insulation piece warranty on Ball Valves
~ DIAMONDBACKtrade
~) Platform Stands
Lift the Mitsubishi Electric Comfort Solution
outdoor unit to new heights with our Diamondback Platform Stands
bull Easy to install
bull Available for all sizes of Mr Slim outdoor units
bull Color matched to the outdoor units
Model Number DSD-400N
L 15-34 x W 3-14 x H 3-14
r
)MITSUBISHI ELECTRIC 29
~ DIAMONDBACKtrade LINESETS
~~
Twin-Tube Lineset Insulation Design
bull Balanced outside diameter for uniform coiluncoil position stability
bull Minimum 12 insulation thickness on both tubes Diamondback Advantages include the following features
bull Quick efficient and economical field installation using factory applied Twin Tube insulation and flare connections with flare nuts mounted
bull Correct lengths for reducing waste and time
bull Quality consistency and economy
bull All Diamondback Lineset tubing is tested in accordance with ASTM E243
Filter Boxes
FB Series filter boxes are available in compatible sizes for all Mr Slim horizontal ducted indoor units
FBL 1 filter boxes include 1 thick pleated MERV 8 filter(s) installed Filters are tested in accordance with ANSIASHRAE Standard 522 and Rated Class 2 under UL Standard 900
The cabinet is constructed of non-insulated 20 gauge G-60 galvanized
FBL1-1 FB Series Filter Box for SEZ-KD09NA
FBL1-2 FB Series Filter Box for SEZ-KD12KD15-NA
FBL1-3 FB Series Filter Box for SEZ-KD18NA
steel with foam gasket and provides an air-tight connection to indoor unit and access door Gasket material complies with UL 723 requirements
A screw-through cabinet design for secure attachment to indoor unit and return connection in rear is easily field-converted to bottom return
30 MITSUBISHI ELECTRIC
bull
bull
bull
bull
bull
bull
LINE-HIDE~ Put a professional finish on air-conditioning
installations with an easy-to-install modular
system that beautifies exteriors and
protects Linesets drainlines and wiring
Can be use it indoors too Meets UL94v-O for interior applications
Has snap-on covers and a full selection of couplings elbows T-joints caps and more for any application complex or simple
Offers high-quality PVC with UV inhibitors for outdoor service in all weather conditions
Can be painted with most house paints to match exterior decors
Is not just for HVAC Hide any exterior cabling piping or wiring
Available in four sizes 2-14 3 4 and 6 tubes
Download a brochure at wwwline-hidecom to find out more information
For more information on our CITY MULTI VRF product line visit our website at wwwmitsubishiprocom
_lIJrUlllln ~ ~IIII1 fInll l
~
l bull bull
JMITSUBISHI ELECTRIC 31
----
MITSUBISHI ELECTRIC 5
Innovative Variable-speed Compressor Technology Sophisticated electronic control systems detect any changes in room or zone temperashyture and-like a cars cruise control-automatically adjust the speed of the outdoor units INVERTER-driven compressor and electronic linear expansion valve (LEV) position for Rprecise capacity control The INVERTER-driven compressor is unlike those found in other systems which only start and stop repetitively Special components within the INVERTER compressor such as high density windings in the motor that increase the magnetic flux and artificial magnets in the rotor to reduce its weight allowi it to operate at higher energy efficiencies with better performance than ever before while producing low sound levels both during start-up and operation
MUZ-FE H2i Heating Capacity at Low Temperatures
120 - -~ I
gc100 --~--~~~~~~--~~~~~~
~ 80~~~~~~-+---~--~~~~--+-~shy()
OJ 60 ------+---j----t---t----t----t---J ~ _ MUZ-FE12NA
Q) 40 _ MUZ-FE18NA I __ UNITARY
~ 20 ---r--+---r--+--~--r-~~~--~~shy
o -13 -4 0 5 10 17 25 30 35 40 47
Outdoor Temperature Degrees FWB
Includes correction for defrost
-
~ l
~ Q) a E ~ 0 ~
o
Heat and Lots of It In addition to the already innovative INVERTER-driven compressor the MSZ -FE high-efficiency systems are also ENERGY STARreg rated and tax credit qualified up to 26 SEER delivering exceptional heating performance
These systems provide heating down to -130 F outdoor ambient and produce up to 100 heating capacity at 50 F MSZ-FE0918 92 capacity at 50 F for MSZ-FE12 Our systems provide year-round comfort in extreme climates while being extremely energy efficient There usually is no need for resistance electric or other supplemental energy-consuming devices with this performance
1seesensor i-seetrade Sensor (MSZ-FE0912NA models only)
The i-see Sensor detects temperature variations in hardshyto-control ceiling and floor areas and controls the airflow up to a wide lateral angle for ultimate comfort (900 angle in cooling mode) By scanning the room and adjusting airflow based on ambient temperature readings MSZ -FE systems achieve superior coolingheating performance with extremely efficient operation
INVERTER model Reaches set point quickly and uniform temperatures are maintained by finely-tuned control of compressor speed
Conventional model Takes longer to reach set point while the temperature is adjusted by switching the compressor off and on consuming additional energy
~ f------------ --_Time ---
Vl l
09shy(I)
I
N 0 l (I)
Vl ltV) (I)
3 0 lt(I)
s (I)
~ OJ l 0 --I (I) n r l 0 0
~
Superior Operation
Advanced Control Technology Through Mitsubishi Electrics advanced controls technology the indoor unit is powered by the outdoor unit Three polarity sensitive wires plus a ground conductor run from the outdoor to the indoor unit providing both power and data communication An advanced wireless remote control is standard on all ductless models An optional wired on-the-wall controller is available for wallshymountedfloor-standing indoor units on INVERTER systems (also requires MAC-397 If adapter) while standard on SEZ -KD ducted units
Quiet Operation Do you hear that No Mitsubishi Electric systems operate at low sound levels our indoor units produce decibels barely at a whisper level Compare to other common sounds
Police siren 118 decibels Circular saw 107 decibels Vacuum cleaner 74 decibels Whisper-tone voice 35 decibels Library reading room 33 decibels Our Indoor Units 19 - 34 decibels (at low speed)
Did you hear that We hope you did
Warm Air No Drafts Our hot-start heat-pump technology provides warmth from the beginning The fan increases in speed as the coil is warmed reducing drafts so when you want warm air you get it
TEMP
88
System Control Mitsubishi Electric offers a comprehensive remote controller that can adjust temperature fan speed and more Choose from four modes COOL HEAT AUTO and DRY The controller also has a 12-hour ONOFF timer for one-button control of your personal comfort
Easy to Maintain With easily accessible filters little or no ductwork to clean and simple wiring between the indoor and outdoor units Mitsubishi Electric systems require minimal maintenance providing another level of convenience
Auto Changeover on Heat-Pump Systems (MUZISUZ outdoor units)
Our heat-pump systems sense whether a space needs cooling or heating and automatically switch modes as needed to maintain a consistent temperature You can set it and forget it
6 MITSUBISHI ELECTRIC
----
Hybrid Catechin pre-filters -- shy
- shy
Total Comfort
Additional Air Circulation With the WIDE VANE or SWING mode available on the MSY(Z)-GE24 D3036NA there is an option for ~~~~lQcnborizontal airflow directions that provide 150
0
of lateral airflow for greater conditioned air circulation
-- -----_ ~~ iii
~~---- 150
0
Multiple Filters for Cleaner Healthier Ai r Mitsubishi Electric indoor units use a sophisticated multi-part filter system to remove contaminants such as allergens viruses and bacteria from the air
A hybrid catechin pre-filter absorbs odorshycausing gases The hybrid-coating process makes the catechin filter washable and - if properly maintained with regular cleaningshyremains effective for up to 10 years
A Blue-enzyme anti-allergen filter reduces germs bacteria and viruses and helps trap dust pollens mites and other particles The filter uses an enzyme catalyst to help break down the sulfur atom bonds in allergen proteins transforming them into non-allergen proteins and effectively cleaning the air The filter should be cleaned regularly to maintain efficiency
STANDARD FILTER SYSTEM (USED IN MSYMSZmiddotGElFE18GND MODELS)
Front Panel - shy
Blue Enzyme anti-allergen filter
ENHANCED FILTER SYSTEM (USED IN MSZmiddotFE0912NA MODELS)
Programmable Comfort Smart Set featured on MSZ-GE systems provides the option to program multiple settings into one quick-press feature providing an additional level of comfort control
The POWERFUL mode (found on select systems) is available to cool or heat any desired space quickly by lowering the set temperature in cooling mode or raising the set temperature in heating mode both by T F In POWERFUL Mode the fan speed increases for 15 minshyutes then the system resumes all standard operations
Vl l
OQ
([) I
N o l ([)
Vl lt(n r-+ ([)
3 o lt ([)
s ([)
~ OJ l a --I ([) nr l o o ~
The high-efficiency MSZ-FE0912NA indoor units incorporate the standard Catechin filter plus two more filters for triple filtration The second filter a Blueshyenzyme filter made of a fibrous material renders allergens harmless by using enzymes The third filter a Platinum Catalyst Deodorizing filter has a ceramic surface absorption element and uses nanotechnology for high-power odor absorption Periodic cleaning following the recommended procedures will maintain filter effectiveness for up to two years This combination of filters provides a complete air-purifying system within the ultimate comfort solution
Front Panel - shy
Hybrid Catechin pre-filters
cJ shy Blue Enzyme anti-allergen filter
I
MITSUBISHI ELECTRIC 7
---- -- -- -
System Lineup RESIDENTIAL AND LIGHT COMMERCIAL SYSTEM MODELS AND CONTROLLERS
SINGLE
MSMU Air Conditioners
9500 to 12000 Btuh 13 SEER
bull Provides cooling-only system bull Non-INVERTER rotary compressor bull Ideal for spaces such as
bedrooms garages out-buildings video monitoring
- ROOM WALL-MOUNTED Ale (cooling only)
MSYMUY Air Conditioners
3800 to 34600 Btuh Capacity Range 151 - 21 SEER
~ -
bull Cooling-only system bull INVERTER-driven compressor bull WIDE VANE for a wider angle of airflow 150
0
from left to right (on GE24D30D36 models)
bull Ideal for spaces such as bedrooms garages large open rooms and bonus rooms
SINGLE-ROOM WALL-MOUNTED HEAT PUMPS (coo lin g and heatin g)
MSZMUZ Heat Pumps
3800 to 33200 Btuh Capacity Range
145 - 21 SEER 82 - 10 HSPF
bull Uses INVERTER-driven compressor bull Provides cooling and heating in a wide range
of capacities bull Offers a WIDE VANE for a wider angle of airflow 1500 from
left to right (on GE24D30D36 models) bull Ideal for applications in bedrooms home offices living
rooms dining rooms bonus rooms basements kitchens guard houses and more
Up to 26 SEER
MSZMUZ-FE0912NA High - Efficiency Heat Pumps
2800 to 25200 BtuH capacity range 202 - 26 SEER
10 - 106 HSPF
bull INVERTER-driven compressor bull Quiet operation as low as 19dB(A) bull i-seetrade Sensor technology bull Enhanced filtration system bull H2ireg high~heat capabilities (see page 12 amp13)
MSZ-FE09 is 100 percent at 50 F MSZ -FE12 is 92 percent at 50 F MSZ-FE18 is 100 percent at 50 F
SI NGLE-ROOM LOW WALL or FLOOR-STANDING UNIT (fo r use with MXZ -8)
New to our lineup is a Low Wall or Floor-Standing model that can fit into those once difficult installations
MFZ These units provide comfort in spaces such as (For use with MXZ-8 finished attics with knee walls basements with Outdoor Units only) low ceilings and glass-walled sunrooms
bull Provides cooling and heating in Mounted three inches above floor level these models a wide range of capacities provide conditioned air two vents and provide direct
bull Two outlet air vents front-panel access to the filter for easy cleaning The - Upper vent for cooling or heating MFZ can even be recessed in a wall during installation - Bottom vent for heating only provided proper clearances are maintained (Currently there is
bull Flush or recessed installation no 1 1 system with M FZ)
8 MITSUBISHI ELECTRIC
SING LE -ROOM HORIZONTAL- DUCTED HEAT PUMPS (coo lin g and heat ing)
WIR ELESS and W IR ED REMOTE C O NTRO LLERS
PAR-21 MAA Wireless remote controller Set Temperature
for wall-mounted and floor-standing indoor units ----- OnOff
Timer Menu Fan Speed
Fan Speed Filter
Test Run Set Time
CheckEcono Cool
Airflow UpDown Timer OnOff
Louver
Ventilation
Reset ---- shy Optional wired controller for the SEZ SLZ and MFZ indoor units (Optional controller for wall-mounted is
available and floor-standing indoor units Unit requires MAC-397 If adapter)
MHK1 WIRELESS REMOTE CONTROLLER Exclusive for INVERTER-driven Mr Slimreg Systems
Wireless Technology a SEZ and SLZ 11 systems with SUZ outdoor unit only
MIFH1
MITSUBISHI ELECTRIC 9
AMITSUBISHI ELECTRIC
l~ 1000
~r t ~~~O
MRCH1
rtj n-shy --1r-a-1-shy
Mode ------ -- shy
SEZSUZ If your customer is looking for discrete zoned comfort then a short-run ducted unit Heat Pumps is the right solution As a stand-alone system or connected to a MXZ multi-room
3800 to 19000 BtuH system the SEZ ducted units provide energy efficiency quiet operation and a Capacity Range compact design for quick easy instqllation hidden either in the ceiling or beneath
15 SEER _---~~mm the floor 175 - 10 HSPF
J ~ All of the 11 systems are ENERGY STAR certified and two systems qualify for
~ the federal tax credit These systems provide customers with an environmentally friendly indoor unit with a similar installation and familiar style
These SEZ indoor units also connect to MXZ multi-zone systems providing a wide array of installation options to best fit any application
SING LE -R OO M C EI LING -REC ESSED CASSETTE UN IT
SLZSUZ Heat Pumps The SLZ -KA ceiling-recessed units casette offer a wide
3100 to 22200 BtuH air-flow pattern for better air distribution in a less obtrusive Capacity Range style These indoor units can be used in 11 heat pump
15 - 16 SEER and multi-zone systems providing more options to your customers Install SLZs in a hard ceiling (with a access panel for
bull 96 HSPF
servicing) or in a 2x2 extra space drop ceiling With a built-in drainshylift mechanism for condensate removal and a 4 ventilation-air intake knockout option and multiple options for the 11 systems the SLZ
~ ~ handles a variety of installation needs
Two of the three 11 systems are ENERGY STAR qualified
Vl l
OQ
(I) I
N o l (I)
Vl ltV (I)
3 Vl r o ~ n OJ V (I)
1shy(MS-A12WA MODEL SHOWN)
MS COOLING-ONLY
IJON-INVERTER
Model Name Indoor Unit
Outdoor Unit
MS-A09WA MS-A12WA
MU-A09WA MU-A12WA
Cooling 1
Rated Capacity Btuh 9500 12000
Capacity Range Btuh
Total Input W 870 1070
Energy Efficiency SEER 13
Moisture Removal Pintsh 27 32 Sensible Heat Factor 068 070
Power Supply Phase Cycle Voltage 1 Phase 60Hz 115V 2
Voltage Indoor - Outdoor L1-N AC 115V Indoor - Outdoor N-2 AC 115V Indoor - Remote Controller Wireless Type
Indoor Unit
MCA A 12
Fan Motor FLA 095
Airilow (Lo-Med-Hi Poweriul)
DRY (CFM) 183-261-335-367 222-286-406-446
WET (CFM) 162-233-300-328 198-254-363-399
Sound Pressure Level (Lo-Med-Hi)
dB(A) 26-32-40-42 33-38-45
External Finish Color Munsell No 1OY 9202
Dimension Unit
W In 30-1116
0 In 8-14
H In 11-34
Weight Unit Lbs 23
Field Drainpipe Size 00 In 58
Outdoor Unit
MCA A 14 16
MOCP (Time Delay) A 15 20
Fan Motor FLA 063 093
Compressor
Model (Type) Single Rotary
RLA 93 1082
LRA 47 56
Airilow CFM 1083 1327
Refrigerant Control Capillary Tube
Sound Pressure Level (Cooling) 1
dB(A) 47 52
External Finish Color Munsell No 3Y 7811
Dimensions
W In 31-12 33-716
0 In 11-14 11-716
H In 21-58 23-1316
Weight Lbs 78 96
Remote Controller Type Wireless Remote
Refrigerant
Type R410A Charge Lbs Oz 25 31
Oil Type (FI Oz) NE022 (108)
Refrigerant Pipe
Gas Side 00 In 38 12
Liquid Side 00 14
Height Difference (Max) Ft 35
Length (Max) 65
Connection Method IndoorOutdoor FlaredFlared
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling) - Indoor DB 800 F(270 e) WB 670 F(190 e) Outdoor DB 950 F(350 e) WB 750 F(240 e) 2 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice
LlIVIITED WARRANTY ISeven-year warranty on compressor Five-year warranty on parts
10 MITSUBISHI ELECTRIC
I
R ---I Vl
J(MSY-GE1 7NA MODEL SHOWN) OQ
MSY COOLI NG-ON LY (CO NT ) CD N o J CD
s Vl OJ J
Cooling 1 0shy
s Vl -lt Vl
~~~~~-=~------~~--------------------------~~~~----------------------------~ jVoltage
205-272-335shy145-170-237 -321-399
420-533 170-237 -300shy
385-498
26-32-38-44-49Indoor Unit
Outdoor Unit
194-240-304shy385-498
28-33-38-44-49
388-469-628-738
347-420-562-661
34-41-49-53
CD n 3-i n OJ 0389-639-848 o J350-576-763 V)
32-42-49
2 9 43Refrigerant
FV50S (040) NE022 (295)
Refrigerant Pipe
Refrigerant Pipe Length
Connection IndoorOutdoor FlaredFlared
Method
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling) - Indoor DB 80deg F(27deg e) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice
LIMITED WARRANTY ISeven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 11
~ (MSZ-FE12NA MODEL SHOWN)
MSZ HEAT PUMP TAX
CREDIT
Model Name
Cooling 1
Indoor Unit Outdoor Unit
Rated Capacity Btuh
MSZ-GE09NA MUZ-GE09NA
9000
MSZ-FE09NA HshyMUZ-FE09NA bull
9000
MSZ-GE12NA MUZ-GE12NA
12000
MSZ-FE12NA MUZ-FE12NA
12000
H-bull MSZ-G MUZ-G
14000
Capacity Range Btuh 3800-12200 2800-9000 3800-13600 2800-12000 3100-18200
Total Input W 660 (205-1200) 580 (160-650) 960 (205-1300) 930 (160-960) 1080 (160-2000)
Energy Efficiency SEER 21 26 205 23 21
Moisture Removal Pintsh 15 21 25 29 27
Sensible Heat Factor 082 076 074 073 080
Heating at 47deg F 2
Rated Capacity Btuh 10900 10900 14400 13600 18000
Capacity Range Btuh 4500-14100 3000-18000 5500-18100 3000-21000 4800-20900
Total Input W 760 (255-1200) 710 (150-2250) 1170 (340-1660) 950 (150-2250) 1600 (270-2010) HSPF (IV) BtuhlW 10 106 10
Heating at 17deg F3 Rated Capacity Btuh 6600 6700 8800 8300 11300 Rated Total Input W 700 650 900 800 1150 Maximum Capacity Btuh 8700 12500 11200 13600 15900
Heating at 5deg F Maximum Capacity Btuh 7061 10900 9194 12500 13022
Power Supply Phase Cycle Voltage 1-phase 60Hz 208 230V 4
Voltage
Indoor - Outdoor S1 - S2 AC 208 230V
Indoor - Outdoor S2 - S3 DC12-24V
Indoor - Remote Controller Wireless Type (Optional Wired Controller DC 12V)
Indoor Unit
MCA A 10
Fan Motor FLA 076
Airflow at Cooling (Lo-Med-Hi-Super HI-Powerful) 1
DRY (CFM) 145-170-237-321-399 162-226-339-381 145-170-237-321-399 162-226-381-410 205-272-335-420-533
WET (CFM) 109-134-201-286-364 144-202-307-343 109-134-201-286-364 144-202-350-367 170-237-300-385-498
Airflow at Heating (Lo-Med-Hi-Super HI-Powerful) 2
WET (CFM) 145-170-237-321-406 166-240-367-381 145-170-237-321-406 166-240-399-420 205-247 -304-367-463
Sound Pressure Level at Cooling (Lo-Med-Hi-Super HI-Powerful) 1
dB(A) 19-22-30-37-43 22-31-39-42 19-22-30-37-45 22-33-43-45 26-32-38-44-49
Sound Pressure Level at Heating (Lo-Med-Hi-Super HI-Powerful) 2
dB(A) 19-22-30-37-43 22-31-40-42 19-22-30-37-43 22-33-43-44 26-30-35-40-46
External Finish Color Munsell No 10Y 92 I 02
Dimension Unit
Wln 31-716 31-38 31-716 31-38 31-716
0 In 9-118 10-18 9-18 10-18 9-18
H In 11-58
Weight Unit Lbs 22 27 22 27 22
Field Drainpipe Size 00 In 58
Outdoor Unit
MCA A 12
MOCP A 15
Fan Motor FLA 050 056 050 056 050
Compressor
lVIodel (Type) DC INVERTER-driven DC INVERTER-driven Twin
Rotary DC INVERTER-driven DC IIWERTER-driven Twin Rotary
RLA 66 86 66 86 74
LRA 82 108 82 108 93
Airflow (CoolingHeating) CFM 11511225 1102 11187 12291172 1102 11187 12431229 Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(A) 46 48 49 48 49
Sound Pressure Level at Heating 2 dB(A) 50 49 51 49 51
External Finish Color Munsell No 3Y 78 11
Dimensions
Wln 31-12
0 In 11-114
H In 21-58
Weight Lbs 66 80 77 80
Remote Controller Type Wireless Remote (Optional Wired Controller)
Refrigerant
Type R410A
Charge Lbs Oz 112 29
Oil Type (fl oz) NE022 (108) NE022 (152)
Refrigerant Pipe Gas Side 00 In 38 12
Liquid Side 00 In 14 14
Refrigerant Pipe Length Height Difference (Max) Ft 40
Length (Max) Ft 65 I
Connection Method IndoorOutdoor FlaredFlared
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg e) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg e) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg e) Outdoor DB 47deg F(8deg e) WB 43deg F(6deg e) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg e) Outdoor DB 17deg F(-8deg e) WB 15deg F(-9deg e) 4 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice
12 +MITSUBISHI ELECTRIC LIMITED WARRANTY ISeven-year warranty on compressor Five-year warranty on parts
- shy(MSY(Z)-D30NA MODEL SHOWN)
Vl J
09 (I)
I
N o J (I)
s Vl N Vl
-0 (I) n 31 n OJ 0 o J V)
Model Name Indoor Unit MSZ-GE18NA MSZ-FE18N MSZ-GE24NA MSZ-D30NA MSZ-D36NA
Outdoor Unit MUZ-GE18NA MUZ-FE18rK MUZ-GE24NA MUZ-D30NA MUZ-D36NA Rated Capacity Btuh 17200 18000 22500 30700 33200
Capacity Range Btuh 3700-18700 8200-25200 8200-31400 9800-30700 9800-33200
Total Input W 1640 (240-2070) 1270 (570-2280) 1800 (570- 3580) 3850 (620-3850) 4360 (620-4360) Cooling 1
Energy Efficiency SEER 192 202 190 145
Moisture Removal Pintsh 46 27 27 99 11 3
Sensible Heat Factor 071 084 075 064 062
Rated Capacity Btuh 21600 21600 27600 32600 35200
Capacity Range Btuh 3500-25200 7500-29700 7500-36900 8700-34000 8700-36000 Heating at 47deg F 2
Total Input W 1900 (230-2680) 1540 (520-2240) 2340 (520- 3650) 3360 (520-3600) 3840 (520-4100)
HSPF (Region IV) BtuhIW 10 103 10 82
Rated Capacity Btuh 13400 11700 16000 19500 21800
Heating at 17deg F 3 Total Input W 1450 2180 3290 2400 2820
Maximum Capacity Btuh 17200 19300 24600 20800 22800 Heating at 5deg F
Maximum Capacity Btuh 13562 21 600 21160 16305 19090
Power Supply Phase Cycle Voltage 1 Phase 60Hz 208230V 4
Indoor - Outdoor S1-S2 AC 208 230V Voltage Indoor - Outdoor S2-S3 DC12-24
Indoor - Remote Controller Wireless Type (Optional Wired Controller DC12V) MCA A 10 Fan Motor FLA 076
DRY (CFM) 230-275-339-420-533 388-469-628-738 388-469-628-738 389-639-848 Airilow (Cool) (Lo-Med-Hi-Super HI-Poweriul) 1
WET (CFM) 194-240-304-385-498 347-420-562-661 347-420-562-661 350-576-763
Airilow (Heat) (Lo-Med-Hi-Super HI-Poweriul) 2 DRY (CFM) 230-275-339-431-512 388-469-628-738 388-469-628-738 445-639-848
Sound Pressure Level (Cooling) (Lo-Med-Hi-Super 28-33-38-44-49 34-41-49-53 34-41-49-53 32-42-49
HI-Poweriul) 1
Sound Pressure Level (Heating) (Lo-Med-Hi-Super dB(A)
Indoor Unit 28-33-38-43-48 32-41-49-52 32-41-49-52 34-42-49-49HI-Poweriul) 2
External Finish Color Munsell No 1 OY 9202
W In 31-716 43-516 46-116
Dimension Unit D In 9-18 9-38 11-58
H In 11-5 8 12-1316 14-38
Weight Unit Lbs 22 37 40
Field Drainpipe Size OD In 58
MCA A 14 171 21
MOCP A 15 20 25
Fan Motor FLA 093
Model (Type) DC INVERTER-driven Twin Rotary
Compressor RLA 100 129 16
LRA 125 161 20
Airilow CFM 1730 1659 17691 701 1941
Outdoor Unit Refrigerant Control Linear Ex~ansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(A) 54 55 56
Sound Pressure Level at Heating 2 dB(A) 56 55 57
External Finish Color Munsell No 3Y 7811
W In 33-116
Dimensions D In 13
H In 33-716 34-58 33-716
Weight Lbs 119 141
Remote Controller Type Wireless Remote (Optional Wired Controller)
Type R410A
Refrigerant Charge Lbs Oz 3 7 43 410
Oil Type (FI Oz) NE022 (152) FV50S (135) NE022 (29)
Gas Side OD 12 58In
Refrigerant Pipe Liquid Side OD 14 38
Height Difference (Max) 50
Length (Max) Ft
100 I Connection
Mpthon IndoorOutdoor Flared Flared
NOTESTest conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg C) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F (24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F(6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 17deg F(-8deg C) WB 15deg F(-9deg C) 4 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice LIMITED WARRANTY ISeven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 13
(SEZ-KD12NA MODEL SHOWN)
SEZ HEAT PUMP TAX
CREDIT
Model Name Indoor Unit SEZ-KD09NA4 SEZ-KD12NA4 SEZ-KD15NA4 SEZ-KD18NA4
Outdoor Unit SUZ-KA09NA SUZ-KA12NA SUZ-KA15NA SUZ-KA18NA Rated Capacity Btuh 8100 11500 14100 17200
Capacity Range Btuh 3800-10900 3800-13300 3800-17000 3800-19000
Cooling 1 Total Input W 670 920 1170 1380
Energy Efficiency SEER 15 16 155 175 Moisture Removal Pintsh 15 24 26 34 Sensible Heat Factor 080 076 080 079
Rated Capacity Btuh 10900 13600 18000 21600
Heating at 4YO F 2 Capacity Range Btuh 4800-14100 4800-16400 4800-21100 4800-24900
Total Input W 1020 1140 1500 1700 HSPF(lV) BtuhIW 100 Rated Capacity Btuh 6700 9000 11900 13100
Heating at 1 yo F 3 Rated Total Input W 810 920 1200 1350 Maximum Capacity Btuh 7300 9800 13700 15000
Power Supply Phase Cycle Voltage 1 Phase 60Hz 208 230V 4 Indoor - Outdoor S1 - S2 AC 208-230V
Voltage Indoor - Outdoor S2 - S3 DC 12-24V Indoor - Remote Controller See optional accessories chart (pg 26 and 27) MCA A 1 Fan Motor FLA 051 057 074
Airflow (Lo-Med-Hi) DRY (CFM) 194-247-317 247-317-388 353-441-529 423-529-635
WET (CFM) 174-222-285 222-285-349 317 -396-4 76 381-476-572 External Static Pressure 3 In wG 002-006-014-020 Sound Pressure Level dB(A) 23-26-30 23-28-33 30-34-37 30-34-38
Indoor Unit External Finish Galvanized-Steel Sheets
W In 31-18 39 46-78
Dimension Unit D In 27-916
H In 7-78
Weight Unit Lbs 42 50 54 62 Field Drainpipe Size 00 In 1-14
MCA A 12 14
MOCP A 15 Fan Motor FLA 050 093
Model DC Inverter DC Inverter Twin Rotary
I (Type)Compressor
RLA 66 74 10
LRA 82 93 125
Airflow (CoolingHeating) CFM 11511225 12291172 1 2431 229 17301659
Outdoor Unit Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(A) 46 49 54 Sound Pressure Level at Heating 2 dB(A) 50 51 56
External Finish Color Munsell No 3Y 7811
W In 31-12 33-16
Dimensions D In 11-14 13
H In 21-58 33-716
Weight Lbs 66 77 80 119 Remote Controller Type See optional accessories chart (pg 26 and 27)
Type R410A
Refrigerant Charge Lbs Oz 116 2 9
Type (fl Oil
oz) NE022 (108)
Refrigerant Pipe Gas Side OD In 38 Liquid Side 00 In 14
Refrigerant Pipe Height Difference (Max) Ft 40 Length Length (Max) Ft 65
Connection IndoorOutdoor FlaredFlared
Method
316
NE022 (152)
12
50
100
I
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg C) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F(8deg C) WB 43deg F(6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 17deg F(-8deg C) WB 15deg F(-9deg C) 4 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
14 MITSUBISHI ELECTRIC
SEZ STATIC PERFORMANCE CURVES (SEZ-KD12NA4 MODEL SHOWN)
SEZ-KD09NA4 SEZ-KD09NA4 (External static pressure O06[inwG]) 208230V 60Hz
[020] V L
5 [016
~l [0 12
]
SEZ-KD09NA4
~ ltij
~ [008
Jj
]
]
[004J ~
V V Middle
Low
V
19h
Rated point
1
o [141] [176J 1212) )247] [282J [318]
Airll ow rat e [CFM)
SEZ-KD12NA4 (External static pressure O06[inwG]) 208230V 60Hz
[020
5 [016
]
]
[353J
Limit
]
~ V
~ [ [0 12
u ltijJ[008
[004
]
_V ]~ Low
V
k-iddle
Rated POint
o [212) [247] [2 82] [318] [353] [388]
Airtlow rate [C FM]
SEZ-KD1SNA4 (External static pressure O06[inwGl) 208230V 60Hz
[424)
1020]
5 [016
~ ~ [012
~ ltij
~ [008
Jj
J
)
]
[004 ]
o
VV V [ Low
VV
vV High
Middle
I Rated point
[282] [318) [353] [388] [424] [459] [494] [530] [565J
Airllow rat e [CFM]
SEZ-KD18NA4 (External static pressure O06[inwG]) 208230V 60Hz
50 10 20]
] 40
5 [016
s 30 [ (012 )
ltij 20 ~ [008 )~Jj
10 [004]
V
Low
v Limit
rIV High
V [ Middle
~
1
Rated point
f318) [353) [388] [424] [459] [494] [530] [565] [600] [636] [671 )
Airllow rate [CFM]
(External static pressure O14[inwG]) 208230V 60Hz 80
[0 32
70 [028
5 60 [024
20 [0 08
10 [004
]
]
J
]
]
J
]V
]
U~it
V
k
High
~V Rated POI~1 V Middle Low
~
o [141] [1 76] 12121 )247J [282] [318]
Airtlow rate [CFM)
SEZ-KD12NA4 (External stat ic pressure O14[inwG]) 208230V 60Hz
[032]
[028J
5
[353]
J
~ [024
-~ [020] V-is
J V Il Hi9h Rated point
[016
~ ]
V V1 Middle
~ [012
[008]~
[004)
o [212)
[247)
SEZ-KD1SNA4
Low r
[282] [31 8) [353]
Airllow rale [CFM]
[388]
(External static pressure O14(inwG]) 208230V 60Hz
[032J
[424
]
2 V[028
5 [024]
V-i
] V High i [020
] K
Middle Rated point [0 16
g ]
~ -
QJj [0 12
J Low
[008
] I
~
[004
o [282J [318) [353J [388J [424) [459] [4 94] [530) [565)
Airt low rate [CFM]
SEZ-KD18NA4 (External statiC pressure O14(inwG]) 208230V 60Hz
1032
1028
~ 1024
-~ [0 20
is (0 16 ltij E ~ [012
(008
(004
o
I
]
]
)
]
)vlt ]
]
~ V
VV
Low
Limit
V
Ji9h
Middle l
Rated point
1 t
1
~ [318] [353] [388] [424] [459) [4 94] [530) [565) [600] [636] [671)
Airllow rate [CFM]
(External static pressure O20(inwG]) 208230V 60Hz
[032 ]
[028 J
5 [024
~ [020
is [016
1 [012Jj
[008
[004
J
]
]
] )
]
V Low
umz V High
~V
Rated point
Middle
1
[141] [176] [212) [247) [282) [318) [353J
Airtlow rat e [CFM]
SEZ-KD12NA4 (External static pressure O20(inwG]) 208230V 60H z
[032 ] LLimit
)
[0 28
5 ]
V
[024 -~ [020] V Rated point
Highis ~
) V
bull Middle
]~V I
[016
~ ~ [012
] Low
[008
]
[0 04
o [212) [247] [282] [318] [353] [388] [424]
Airllow rate [CFM]
SEZ-KD1SNA4 (External static pressure O20(inwG]) 208230V 60Hz
80 [032 ]
70 [0 28
~ [ O~~ -
ltij
E 30 ~ [0 12
20 [008
10 [004
o
)
J
]
]
JV
J
J
Limit V
LV High
V ~
K Rated point
Middle
VV 1gt
Low
I-
~ [282) [318) (353] (388) (424) 1459] [494] 15301 [565)
Airtlow rate [CFM]
SEZ-KD18NA4 (External static pressure O20[inwG]) 208230V 60Hz
[032
[028
~ [024sect
I [020
~ [016
~ Jj [0 12
[008
[004
o
]
)
]
]
]
~ )
]
]
1V
V 1
V
Low
1 limit
~~~ I ~~ High
~ R~ted pOini
Middle
1 1 -
[31 8) [353] [388] [424) [459] [494] [530] (565) [600] (636) [671J
Airllow rate [CFM)
Vl ~ ca (I)
I
N o ~ (I)
Vl m N Vl
-0 (I) n 3-i n QJ ~ o ~ tn
Note ESP 20S230V 60 Hz See manual for Static Performance Curve including 002 in WG
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts ~MITSUBISH[ ELECTRIC 15
SLZ HEAT PUMP (SLZ-KA12NA MODEL SHOWN)
Model Name Indoor Unit SLZ-KA09NA SLZ-KA12NA SLZ-KA15NA
Outdoor Unit SUZ-KA09NA SUZ-KA12NA SUZ-KA15NA Rated Capacity Btuh 8400 11100 15000
Capacity Range Btuh 3100-10900 3100-13300 3100-22200
Cooling 1 Total Input W 700 920 1460
Energy Efficiency SEER 15 154 16 Moisture Removal Pintsh 12 23 45 Sensible Heat Factor 080 076 080
Rated Capacity Btuh 10900 13 600 18000
Heating at 4r F 2 Capacity Range Btuh 3100-14100 3100-17100 3100-17100 Total Input W 930 1180 1950 HSPF (IV) BtuhIW 96 Rated Capacity Btuh 6200 8300 10200
Heating at 17deg F 3 Rated Total Input W 740 930 1310 Maximum Capacity Btuh 8300 10200 12000
Power Supply Phase Cycle Voltage 1 Phase 60Hz 208 230V 4 Indoor - Outdoor S1 - S2 AC 208-230V
Voltage Indoor - Outdoor S2 - S3 DC 12-24V
Indoor - Remote Controller See optional accessories chart (pg 26 and 27) MCA A 1 Fan Motor FLA 023 028 028
Airflow (Lo-Med-Hi) DRY (CFM) 280-320-350 280-320-390 280-320-390
WET (CFM) 250-290-320 250-290-350 250-290-350
Sound Pressure Level dB(Al 29-32-38 30-34-39 31-35-40
Indoor Unit External Finish Galvanized-Steel Sheets Grille Munsell 64Y 8904
W In 22-7 16 (25-58)
Dimension Unit (Grille) D In 22-716 (25-58
H In 8-316 (1316)
Weight Unit (Grille) Lbs 36 (7) Field Drainpipe Size 0 0 In 1-14 MCA A 12 MOCP A 15 Fan Motor FLA 050
Model (Type) DC INVERTER-driven DC INVERTER-driven
Compressor RLA 66
LRA 82
Airflow (CoolingHeating) CFM 11511225 1 229 1 172
Outdoor Unit Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(AJ 46 49 Sound Pressure Level at Heating 2 dB(AJ 50 51
External Finish Color Munsell No 3Y 781 1
W In 31 shy12
Dimensions 0 In 11-14
H In 21-58
Weight Lbs 66 77
~e R410A
Refrigerant Charge Lbs Oz 1 16
Oil Type (fl oz) NE022 108)
Refrigerant Pipe Gas Side 0 0 In 38 Liquid Side 00 In 14
Height Difference (Max) Ft 40 Refrigerant Pipe Length
Length (Max) Ft 65
Connection Method IndoorOutdoor FlaredFlared
29
Twin Rotary 74
93
12431 229
80
NE022 l152) 12
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg C) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F(8deg C) WB 43deg F(6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 17deg F(-8deg C) WB 15deg F(-9deg C) 4 Indoor units receive power from outdoor units through field-supplied interconnectedwiring Specifications are subject to change without notice
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
16 MITSUBISHI ELECTRIC
MHK1 WIRELESS REMOTE CONTROLLER KIT Exclusive for INVERTER-driven Mr Slimreg Systems VlWireless Technology a J
JMITSUBISHI ELECTRIC
Wireless Receiver
MHK1 Kit includes
09 mMRCH1 WIRELESS REMOTE CONTROLLER I Nbull Backlit easy-to-read display o
bull Dual setpoint control with system changeover J m
bull Enabled with RedLlNKTM reliability
bull Compatible with MCCH1 Vl Portable Central Controller m
N bull Installs Anywhere Vl
MFH1 WIRELESS RECEIVER N Vlbull Required for MRCH1 Wireless
CRemote Controller m bull Enabled with RedLiNK reliability n
31 n OJ o J en
SEZ and SLZ 11 systems with SUZ outdoor unit
Function Description
ONOFF OnOff operation for a single indoor unit
Operation Mode Cool I Drying I Auto I Heat I Fan only Available operation modes dependant on connected system
Temperature Setting Set temperature from 50degF - 8rF depending on operation mode and connected system
System Changeover Deadband Value 2-8degF
Schedule Operation 5-25-1-1
Fan Speed Setting HiMid-2Mid-1 IlowlAuto Available fan speed settings dependant on connected system
Air Flow Direction Setting Air flow angles 100deg - 80deg - 60deg - 40deg and oscilate Available air flow direction settings dependant on connected system
PermitProhibit Function Individual prohibit operations for each remote controller function (ONI OFF Set Temperature and Operation Mode)
Space Temperature Displays the measured space temperature
Error Indication Displays error code
Display Outside Temperature and Humidity
Requires optional MOS1 Outside Air Sensor
Dimensions - ryv x D x H) Remote Controller 5-316 x 1-12 x 3-916 Receiver 3-14 x 1-516 x 6-716
Operating Ambient Temperature Remote Controller 32 - 120degF Receiver -40 - 165degF
Operating Ambient Humidity Remote Controller 5 - 90 RH (non-condensing) Receiver 5 - 90 RH (non-condensing)
Power Supply 2 AA batteries
MRCH1 MIFH1 MRC1
Wireless Wall-Mounted Remote Controllers Wireless Receiver Cable
Accessories MCCH1 MOS1
Portable Central Controllers Outside Air Sensor
MITSUBISHI ELECTRIC 17
MULTIPLE ROOMS WITH INDIVIDUAL CONTROL FROM A SINGLE SYSTEM Enjoy ideal levels of comfort in the rooms you use most with our multi-room system Each room (zone) operates independently People in different rooms - the kitchen master bedroom or living room - can enjoy temperature settings that make each of them most comfortable
If you re looking for a complete comfort solution for several different rooms the MXZ multi-room system is the right choice The system is flexible enough to conform to a particular cooling and heating need and offers numerous different indoor unit combinations In addition up to eight indoor units can be connected to one outdoor unit Now with a SEZ horizontal ducted unit and a MFZ floorshystanding unit homeowners can enjoy an even greater range of zoning options provided by an MXZ system
An MXZ multi-room system is an excellent choice for supplementing capacity to a current system conditioning newly furnished spaces or new additions and replacing a system within a home Homeowners can also benefit from lower energy costs year-round while staying comfortable thanks to Mitsubishi Electrics energy-efficient technologies that are a part of every system that we make
To add to the level of energy efficiency the MXZ -2B20NA and MXZ -3B24NA systems qualify for both ENERGY STARreg and the federal tax credit (See details on page 21 for applicable indoor unit combinations)
At right a single level home with several system types represented (For illustrative purposes only)
MFZ Floor-Standing Indoor Units for MXZ Heat Pump Systems
Floor-standing indoor unit mounts three inches above the floor and has front panel access to the filter for ease of cleaning
The MFZ units provide energy-efficient solutions to provide personalized comfort for difficult areas that may be smaller or dont have usable space on the walls
MFZ units on MXZ systems include the following features bull Top and bottom discharge vanes bull Hot-start technology bull Quiet operation bull Wireless remote control (optional wall-mounted controller)
18 MITSUBISHI ELECTRIC
MSZ Wall-Mounted Indoor Units for MXZ Heat Pump Systems
Providing a wide range of cooling and heating capacities each wall-mounted indoor unit mounts high on a wall and connects to a branch box or the outdoor unit by a refrigerant line run via a 3 hole The MSZ units provide highly efficient solutions to cooling and heating needs and provide personalized comfort for the individual zones in which they are installed
MSZ units on MXZ systems include the following features bull Sleek flat panel design bull Hot-start technology bull Quiet operation bull i-seeM sensor technology (MSZ-FE0912NA models only) bull Enhanced filtration system (MSZ-FE0912NA models only) bull Wireless remote control (optional wired wall-mounted controller)
SLZ Ceiling-Recessed Indoor Units for MXZ Heat Pump Systems
The new SLZ-KA ceiling casette systems offer a wide air-flow pattern for better air distribution
offered to your customers Installation can be done in a hard ceiling (with a access panel for servicing) or placed into a 2x2 drop ceiling With a built-in drain lift mechanism for condensate
removal and a 4 ventilation air intake knockout option the SLZ is ready to handle a variety of installation needs
SLZ units on MXZ systems include the following features bull Wide air-flow pattern for better air distibution bull 4 ventillation air intake knockout bull Built-in condensate lift mechanism bull Wireless RedLlNKTM remote controller
SEZ Horizontal Ducted Indoor Units for MXZ Heat Pump Systems
SEZ ducted units can provide split air-conditioning system advantages with the added benefit of being concealed to provide virtually no visual footprint within the conditioned space other than a register and grille for the air to flow With the use of short run ductwork these units can provide comfort to a single room that needs air dispersed evenly throughout the space unusually shaped rooms and adjacent rooms
The SEZ unit on MXZ systems include the fOllvowin fatures _
g~e~~~~==Zl[bull Concealed design for short-run ductwork bull Quiet operation bull Built-in condensate lift mechanism
JMITSUBISHI ELECTRIC 19
s c t
I
N o J ro o ltro ~ ro ~
DIAMOND COMFORT MXZ MULTI-ZONE SYSTEMS MXZ-B Series multi-zone systems provide personalized comfort control and energy efficiency in up to eight rooms with only a single outdoor unit The MXZ-B Series system features include
bull Individual zone control bull Mix and match flexibility of indoor unit styles and combinations bull A wide range of indoor unit capacities that match the room size and requirements bull Flexible design options to tackle the most challenging multi-room installations bull Efficient systems including three systems [mxz series] that meet energy starltID and
federal tax credit requirements bull Simple quick and cost-effective installation keeps install costs down on new construction
and disruption to a minimum on renovations and refits
Efficiency and performance ratings depend on the number style and capacity of the indoor units installed with each Multi-Zone System
MXZ -2 B20 NA - 1 (2 1 ) MXZ -3 B24 NA (2 13 1) Ou tdoo r Unit Outdoor Uni t
MSZ-GE09NA Indoor Units
SEZ-KD12NA Indoor Unit
MSZ- GE06NA
~~~~li
(At least two indoor units MSZ-GE06NAIndoor Unit must be installed) Indoor Unit
(Two indoor units must be installed )
MXZ -3 B30 NA (2 1 3 1) Outdoor Unit
SEZ-KD12NA Indoor Unit
~~~i
(At least two indoor units MSZ-GE06NA must be installed)
Indoor Unit ~
MFZ- KD12NA Indoor Unit
MXZ-8B48NA (2 1-8 1) Outdoor Unit
(At least two indoor units
must be installed)
(At least two indoor units must be installed)
MFZ-KD09NA Indoor Units
MSZ-GE09NA Indoor Units
SEZ-KD12NA Indoor Unit
MSZ INDOOR UNIT
MSZ-FE18NA
PEAD HORIZONTAL -DUCTED INDOOR UNIT
PEAD-A24AA
MSZ INDOOR UNIT SEZ HORIZONTAL-DUCTED MSZ-FE18NA
INDOOR UNIT MFZ FLOOR-STANDING SEZ-KD18NA INDOOR UNIT
MFZ-KA12NA
20 AMITSUBISHI ELECTRIC
MULTI-ROOM MXZ-8 INVERTER HEAT PUMP R
Model Name Outdoor Unit MXZ-2B20NA-1 5 MXZ-3B24NA 6 MXZ-3B30NA MXZ-4B36NA 7
Indoor Unit
Cooling 1 Non-ductedl Ducted
Rated Capacity Btuh 1800020000 2200023600 28400127400 3540034400
Capacity Range Btuh 7800-20000 12600-25500 12600-28400 12600-36400
Total Input W 2190 (630-219QL 2460 (1000-2950) 3330 l1 000-3330) 3 940 (1 000-4020)
Heating at 4JO F 2 Non-ductedl Ducted
Rated Capacity Btuh 2200022000 2500024600 2860027600 3600034400
Capacity Range Btuh 8500-25500 11400-30600 11 400-36000 11400-43000
Total Input W 2620 (520-2620) 1900 (740-2600) 2220 (740-2820) 3100 (740-3940)
Heating at 1JO F 3 Non-ductedl Ducted
Rated Capacity Btuh 1250012500 1400014000 1600015100 2220020300
Rated Total Input W 13501430 13801570 21202 140 24302340
Maximum Capacity Btu h 1450014500 1880017000 1880018000 2460025400
Maximum Total Inl2ut W 15001590 21202230 21202140 33403450
Power Supply Phase Cycle Voltage 1-phase 60Hz 2081 230V 8
Voltage Indoor shy Outdoor S1 - S2 AC 2081 230V
Indoor shy Outdoor S2 - S3 DC12-24V
Outdoor Unit 4
MCA A 15 19
MOCP A 20
Fan Motor FLA 096 093
Compressor
Model (Type)
DC INVERTER-driven Twin Rotary
RLA 101 11 144
LRA 15
Airflow (CoolingHeating) CFM 14851 640 20681605 13651605 20682068
Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1
dB(A) 49 54 49 54
Sound Pressure Level at Heating 2
dB(A) 51 49 57
External Finish Color Munsell No 30Y 781 1
Dimensions
W In 33-116 35-716
D In 13 12-58
H In 27-1516 35-7116
Weight Lbs 130 150 153
Indoor Unit No of Units 2 23 23 234
Remote Controller Type Associated with the Indoor Unit
Refrigerant
Type R410A
Charge Lbs Oz 515 7 11 813
Oil Type (fl oz)
NE022 (237) NE022 (294)
Refrigerant Pipe Gas Side 00 In AB 38 A 12 BC 38 A 12 BCD 38
Liquid Side 00 In 14
Refrigerant Pipe Length Height Difference (Max) Ft 4933 9
Length (Max) Ft 164 (A+B) 230 (A+B+C) 230 (A+B+C+D)
Connection Method IndoorOutdoor FlaredlFlared
Compatible with the MSZ-A MSZ-GA MSZ-FD MSZ-FE MSZ-GE MFZ-KA and SEZ-KD series indoor units (PLA-18 amp PCA-24 on the MXZ-MXZ-3B PLA-24 amp PCA-24 on the MXZ-4B)
NOTES Test conditions are based on AHRI 210240 One indoor unit is turned off during low-speed testing under the new test conditions Systems actually exhibit higher energy efficiencies during normal operation
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F (35deg C) WB 75deg F (24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F (6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 600 F (160 C) Outdoor DB 17deg F (_80 C) WB 150 F (_90 C) 4 Refer to pages 12 and 13 for Indoor Unit specifications 5 Data from combination of two Indoor Units 9000 Btuh (non-ducted) or one 9000 Btuh and one 12000 Btuh (ducted) 6 Data from combination of two Indoor Units 6000 Btuh and one 9000 Btuh (non-ducted) or three 9000 Btuh (ducted) 7 Data from combination of four Indoor Units 9000 Btuh (non-ducted and ducted) 8 Indoor units receive power from outdoor units through field-supplied interconnected wiring 9 49 Applies to installations where the outdoor unit is installed below the indoor unit
Power factor equals 97 percent
Specifications are subject to change without notice
MULTI-ZONE ENERGY STAR AND TAX CREDIT SYSTEMS
Model Indoor Unit Combinations SEER HSPF
MXZ-2B20NA-1 2 x MSZ- GE09NA 18 8 9
MXZ- 3B24NA 2 x MSZ- GE06NA 1 x MSZshy GE09NA
17 5 9 3
MXZ- 3B24NA 2 x MSZ-GE06NA 1 x MSZ- GE12NA
17 5 93
For more details on all ENERGY STAR and tax credit systems go to wwwmitsubishicomfortcomtaxcredit
See page 25 for additional info on efficiency
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 21
MXZ-8B48NA THE ULTIMATE ZONING SOLUTION
The Mitsubishi Electric MXZ-S84SNA eight-zone unit As a member of the expanding MXZ-B Series of multi-zone systems the MXZ-8B outdoor unit incorporates branch boxes to connect up to eight indoor units MXZ- 8 B48 NA (2 1 - 8 1 )
Outd oor Uni t The INVERTER-driven compressor at the heart of the MXZ-8B -~-- shy
outdoor unit provides variable capacity control allowing the system to adjust to the specific demands of the interior space ~ as needed not the hard start and stop of a traditional system I[iDA Jinstalled in most US homes
The MXZ -8B48NA has only one port on the outdoor unit for two insulated refrigerant lines which run into the home or business to connect to a branch box or boxes From the branch box(es) gas and liquid refrigerant piping run to each of the indoor units The LEV in the branch box(es) controls the refrigerant flow as the load of each zone changes
Through the branch box(es) (the PAC-AKA31 BC three-port andor the PAC-AKA51 BC five-port) the system can connect from two indoor units up to eight indoor units depending on application requirements
The flexibility of the system doesnt stop there The MXZ-8B48NA has rated capacities of 48000 Btuh for cooling and 54000 Btuh for heating System operation however can range from a minimum 12000 Btuh to a maximum 54000 Btuh in cooling and a maximum of 60000 Btuh in heating This type of performance supports a large variety of applications
The MXZ-8B48NA allows for further flexibility because it supports a connected indoor unit capacity from 22 to 130 or 12000 Btuh to a maximum 70200 Btuh depending on diversity
Connectable Indoor Units General Features bull Four-ton outdoor unit can support up to
eight indoor units using branch boxes bull Wide variety of indoor unit styles
-=--_-=-----= - - J _ 1
including wall-mounted floor-standing MSZ-FE09 12 18NA MSZ-GE06 09 12 15 18 24NA ceiling-cassette ducted
bull Individual control up to eight (8) zones using wired or wireless controls
bull Advanced microprocessor control bull Auto restart following a power outage bull Self-check function offering SEZ-KD09 1215 18NA PEAD-A24AA
integrated diagnostics ~--- Jbull Limited warranty five years on parts and
defects and seven years on compressors
SLZ-KA09 1215NA MFZ-KA09 12 18NA
22 MITSUBISHI ELECTRIC LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
I
RMULTI-ROOM MXZ-8 INVERTER HEAT PUMP
Model Name Outdoor Unit MXZ-BB4BNA Cooling 1 Rated Capacity
Non-ducted Rated Total Input Ducted
Maximum Capacity
Rated CapacityHeating at
Rated Total InputIndoor Unit 4JO F 2 Non-
ductedDucted Maximum Capacity
Rated Capacity Heating at
Rated Total InputlJO F 3 Non-ductedDucted Maximum Capacity
Power Supply Phase Cycle Voltage
Indoor - Outdoor Sl - S2 Voltage
Indoor - Outdoor S2 - S3
MCA
Recommended FuseBreaker Size
Fan Motor
Compressor
Airflow (CoolingHeating)
Refrigerant Control
Outdoor Unit Sound Pressure Level at Cooling 1
Sound Pressure Level at Heating 2
External Finish Color
Dimensions
Weight
Total Capacity 22-130
Indoor Unit ModelQuantity
Remote Controller Type
Type
Refrigerant Charge
Oil
Gas Side OD Refrigerant Pipe
Liquid Side OD
Height Difference (Max)
Maximum Distance between (Outdoor unit and farthest indoor unit)
Refrigerant Pipe Length Maximum Pipe Length -Branch box to Indoor Unit
Total Maximum line length between Branch Box and All Connected Indoor Units
Total Length (Max)
Connection Method IndoorOutdoor
Includes both branch boxes if there are two
Branch Boxes (At least one branch box required)
Btuh
W
Btuh
Btuh
W
Btuh
Btuh
W
Btuh
A
A
Type x Quantity
Motor Output (kW)
Model (Type)
Motor Output (kW)
CFM
dB(A)
dB(A)
W In
D In
H In
Lbs
Btuh
Lbs Oz
Type (fl oz)
In
In
Ft
Ft
Ft
Ft
Ft
4800048000
57806470
54000
5400054000
48205270
60000
3300034700
29503390
3660036550
1 Phase 60Hz 208 230V
AC 208-230V
DC12-24V
32
40
Propeller x 2
0086 + 0086
DC INVERTER-driven Scroll
29
3530
Linear Expansion Valve
54
55
Munsell No 3Y 78 11
37-716
13+1-3 16
53-3 16
278
12000 - 70200
600 - 24000 2-8
Associated with Indoor Unit Model
R410A
18 112
FV50S (73)
58
38
6698 4
230
49
197
377
FlaredFlared
Compatible with the MSZ-A MSZ-FO MSZ-FE MSZ-GE MFZ-KA SEZ-KD PLA and PEAD series indoor units
NOTES Test conditions are based on AHRI 210240 One indoor unit is turned off during low-speed testing under the new test conditions Systems actually exhibit higher energy efficiencies during normal operation
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F (35deg C) WB 75deg F (24deg C)
2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 4]0 F (8deg C) WB 43deg F (6deg C)
3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 17deg F (-8deg C) WB 15deg F(-9deg C)
4 66 applies to installations when the outdoor unit is installed below the indoor unit
Power factor equals 97 percent
Specifications are subject to change without notice
Note Maximum installed capacity is the maximum total of all connected indoor units NOT the maximum capacity produced
Only a single Lineset is needed from the outdoor unit to branch box
See page 25 for MXZ-B information on efficiency
Required Branch Boxes for MXZ-SB4BNA (Maximum of 2 branch boxes can be connected to one outdoor unit requires joint MSDD-50AR-E or MSDD-50BR-E)
s c d N o J ro Vl
0 ro n 3i n OJ d o J U)
PAC-AKA51 BC Branch Box
PAC-AKA31 BC Branch Box LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 23
MSZ WALL-MOUNTED INDOOR UNITS (FOR MXZ-8 OUTDOOR UNITS)
R
(MSZ-GE12NA MODEL SHOWN)
-000 IIIIIII 9000 9000 12000 12000 14000 17200
Heating at 4r Rated Capacity Btuh 7200 10900 10900 14400 13600 18000 21600
F2 Power Supply I Phase Cycle Voltage J -phase 60Hz 208 230V 3
Iindoor Outdoor S1 S2 AC 208 230V
Iindoor Outdoor S2 S3 DC12-24V Voltage
Iindoor Remote vomr Iller Wireless Type (Optional Wired vomroller DC 12V)
IMCA A 10 IFan Motor FLA 076
DRY 162-226shy145-170shy
162-226shy205-272shy 230-275shy
Airflow at Cooling (CFM)
145-170-237-321-399 339-381
237 -321shy381-410
335-420shy 339-420shy(Quiet-Lo-Med-Hishy 399 533 533 Super Hi or Lo-Med-
WET 144-202shy109-134shy
144-202shy170-237shy 194-240shy
Fan Hi-Powerful)1 (CFM)
109-134-201-286-364 307-343
201-286shy350-367
300-385shy 304-385shy364 498 498
Airflow at Heating 145-170shy 145-170shy 145-170shy 205-247shy 230-275shy
(Quiet-Lo-Med-Hi- WET 233-321shy 237-321shy
166-240shy237-321shy
166-240shy304-367shy 339-431shy
Super Hi or Lo-Medshy (CFM) 406 406
367 -381 406
399-420 463 512
Hi-Powerful) 2 Sound Pressure Level at Cooling
19-22-30shy 26-32-38shy 28-33-38shy(Quiet-Lo-Med-Hi-Super Hi or Loshy dB(A) 19-22-30-37 -43 22-31-39-42
37-45 22-33-43-45
44-49 44-49Med-Hi-Powerful) 1
Sound Pressure Level at Heating 19-22-30shy 26-30-35shy 28-33-38shy
(Quiet-Lo-Med-Hi-Super Hi or Loshy dB(A) 19-22-30-37 -43 22-31-40-42 37-43
22-23-43-44 40-46 43-48
Med-Hi-Powerful) 2
I External Finish Color Munsell No 10Y 92 02
IWln 31 middot716
Dimension Unit 10 In 9 18 10-18 9middot18 10-18 9-18
IH In 11-58
I Weight Unit ILbs 22 27 22 27 22 I Field Drainpipe ~D lin 58 Remote Con-
Type Wireless Remote (Optional Wired Controller) troller
ITvpe B41QA Refrigerant ~s$ideOD lin 38 Pipe I Liquid Side 00 In 14
Connection IndoorOutdoor FlaredFlared
Method
1~
II 18000 22500
21600 27600
388-469shy 38$-469shy628-738 628-738
347-420shy 347-420shy562-661 562-661
388-469shy 388-469shy628-738 628-738
34-41-49-53 34-41-49-53
32-41-49-52 32-41-49-52
43-516
9-38
12-1316 37
58 38
MXZ-2B20NA is also compatible with the MSZ-A and MSZ-FD series indoor units NOTES Test conditions are based on AHRI 210240
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F(6deg C) 3 Indoor units receive power from outdoor units through field-supplied wiring
Specifications are subject to change without notice LIMITED WARRANTY Seven-year warranty on compressor Five-year warranty on parts For data on specific indoor unit combinations see page 21
SEZ DUCTED INDOOR UNIT (FOR MXZ-8 OUTDOOR UNITS)
I
Notes 1 Cooling-Indoor DS 80deg F(267deg C) WS 67deg F(194deg C) Outdoor DS 95deg F (35deg C) WS 75deg F(239deg C)
2 Heating-Indoor DS 70deg F(211 deg C) WS 60deg F(156deg C) Outdoor DS 47deg F (83deg C) WS 43deg F(61 deg C)
3 External static pressure is factory set to 006 WGAdjustable via the
1---------t---+-----L-------------1~---__I PAR-21MAA
1--_____----__________+-____---L____----~_____________1 4 Indoor units receive power
jE~~~~-------------r----1-----~-~~~~~~~~-----___1 from outdoor units through fieldsupplied interconnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven-year warranty on compressor Five-year
1---------------------+---+------------------------1 warranty on parts
~--__I_~----------+-------~l----------I For data on specific indoor unit combinations see page 21 - 23
I--~------+~-----------~----------r_------------I
- Reference page 17 for SEZ static performance curves
24 MITSUBISHI ELECTRIC
25-30-35-40 26-31-36-41 35-38-42-46
25-30-35-40 28-31-36-41 35-38-42-47
MFZ FLOORLOW WALL INDOOR UNIT (FOR middotMXZ-8 OUTDOOR UNITS)
------shy
-==
Airflow at Heating (CFM) 177-198-219-332 184-201-219-335 261-275-297-434
Voltage
Fan
Airflow at Cooling (Lo-Med-Hi-Super Hi)1
169-205-251-314 251-279-325-394
163-197-241-303 170-207-252-309 241-269-313-379
(Lo-Med-Hi-Super Hi) 2
SLZ CEILING-RECESSED INDOOR UNIT (FOR MXZ-8 OUTDOOR UNITS) EFFICIENCY RATINGS
Voltage
Fan
Galvanized-steel SheetsMunsell 64Y 89 04
Refrigerant Pipe
Model Indoor Unit Type SEER HSPF
MXZ-2B20NA-1
Non-dueted 18 89
Dueted and Non-dueted 1675 87
Dueted 155 85
MXZ-2B20NA-1 ENERGY STAR amp
TAX CREDIT 2 x MSZ-GE09NA 18 89
MXZ-3B24NA
lJon-dueted 175 93
Dueted and Non-dueted 1625 89
Dueted 150 85
MXZ-3B24NA ENERGY STAR amp
TAX CREDIT
2 x MSZ-GE06NA 1 x MSZ-GE09NA
175 93
MXZ-3B24NA ENERGY STAR amp
TAX CREDIT
2 x MSZ-GE06NA 1 x MSZ-GE12NA
175 93
MXZ-3B30NA
Non-dueted 175 105
Dueted and Non-dueted 16 100
Dueted 145 95
MXZ-4B36NA
Non-dueted 18 93
Dueted and Non-dueted 16 5 92
Dueted 150 9 0
MXZ-BB4BNA
Non-dueted 15 87
Dueted and Non-dueted 14B B8
Dueted 147 89
Connection IndoorOutdoor FlaredFlared
Method
Notes 1 Cooling-Indoor DB 80deg F(267deg C) WB 67deg F(194deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(239deg C) 2 Heating-Indoor DB 70deg F(21 1 deg C) WB 60deg F(156deg C) Outdoor DB 47deg F(83deg C) WB 43deg F(61 deg C) 3 Indoor units receive power from outdoor units through field supplied interconnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 25
Notes 1 Cooling-Indoor DB 80deg F(267deg C) WB 67deg F (194deg C) Outdoor DB 95deg F (35deg C)WB 75deg F (239deg C)
2 Heating-Indoor DB 70deg F(211deg C) WB 60deg F (156deg C) Outdoor DB 47 F (83deg C) WB 43deg F (61 deg C)
3 Indoor units receive power from outdoor units through field supplied interco(lnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven -year warranty on compressor Five-year warranty on parts
Presently there is no 1 1 system with the MFZ indoor unit
s c
N o J ro Vl
C ro n ~ n OJ t o J V)
M-SERIES RATING CONDITIONS
INDOOR INTAKE AIR TEMPERATURE
OUTDOOR INTAKE AIR TEMPERATURE
COOLING
MAXIMUM
95degF DB 71 degF WB (MU SUZ MXZ-2B20-13B243B304B36) 90degF DB 73degF WB (MUZY-GE MUZ-FE MUzy-D)
115degF DB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B24 3B304B368B48)
MINIMUM 67degF DB 57degF WB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B201 3B243B304B36)
14degF DB (MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B24 3B304B36) 23degF DB (MXZ-8B48) 6rF DB (MU)
MAXIMUM 80degF DB 6rF WB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B243B304B36)
75degF DB 65degF WB (MUZY-GE MUZY-GA24 MUZ-FE SUZ MXZ-2B20-1 3B243B304B36) 70degF DB (MXZ-8B48)
HEATING
MINIMUM 70degF DB 60degFWB (MUZ-GE MUZ-GA24 MUZ-D MUZ-FE SUZ MXZ-2B20-1 3B243B304B36)
-13degF DB -15degFWB (MUZ-FE) -4degF DB -5degF WB (SUZ MUZ-GE) 5degF DB 4degF WB (MUZ-GA24 MXZ-8B48NA) 6degF DB 5degF WB (MXZ-2B20-1 3B24 3B304B36) 14degF DB 13degFWB (MUZ-D)
MU units operate at intake air temperature down to 10deg Fwith the addition of an ICM-326HM-1 low temperature control
REFRIGERANT TUBING SETS
OPTIONAL ACCESSORIES
REFRIGERANT LINE LENGTH FLARE FLARE _INDOOR UNIT OUTDOOR UNIT
MS-A09WA MU-A09WA 35 MS-A12WA
65 MU-A12WA 35
MSY-GE09NA 65
MUY-GE09NA 40
MSY-GE12NA
65
MUY-GE12NA 65 40
MSY-GE15NA MUY-GE15NA 40
MSY-GE18NA
65
MUY-GE18NA 100 50
MSZ-GE09NA MUZ-GE09NA 65 40
MSZ-GE12NA MUZ-GE12NA 40
MSZ-GE15NA
65
MUZ-GE15NA 40
MSZ-GE18NA
65
MUZ-GE18NA 100 50
MSY-GE24NA MUY-GE24NA 100 50
MSZ-GE24NA MUZ-GE24NA 100 50
MSY-D30NA MUY-D30NA 100 50
MSZ-D30NA MUZ-D30NA 50
MSY-D36NA
100
MUY-D36NA 50
MSZ-D36NA
100
MUZ-D36NA 100 50
MSZ-FE09NA MUZ-FE09NA 40
MSZ-FE12NA
65
MUZ-FE12NA 40
MSZ-GE06091215NA MSZ-FE0912NA
65
MXZ-2B20NA-1 164 4933MFZ-KA0912NA SEZ-KD09 1215NA
MSZ-GE0609 121518NA MSZ-FE091218N MFZ-KA09 1218NA MXZ-3B24NA 164 4933 SEZ -KD09 12 15 18NA SLZ-KA09 12 15NA
MSZ-GE0609 121518NA MSZ-GA24NA MSZ-FE091218NA
MXZ-3B30NA 4933230MFZ-KA091218NA SEZ -KD09 121518NA SLZ-KA09 12 15NA
MSZ-GE0609121518NA MSZ-GE24NA MSZ-FE09 12 18NA
MXZ-4B36NA 230 4933MFZ-KA091218NA SEZ -KD09121518NA SLZ-KA09 12 15NA
MSZ-GE0609 12 15 18NA MSZ-GE24NA MSZ-FE09 12 18NA
MXZ-8B48NA 6698377MFZ-KA091218NA SEZ-KD09121518NA SLZ-KA09 12 15NA
PART NUMBER I USE WITH I DESCRIPTION
Port Adapters and Connection Pipes MAC-A454JP-E MXZ-Series Adapter 38 X12
MAC-A455JP-E MXZ-Series Adapter 12 X38
MAC-A456JP-E MXZ-Series Adapter 12 X58
MSDD-50AR-E MXZ-Series Branch Box Tee Distribution Pipe - Flare Connection between two branch boxes
MSDD-50BR-E MXZ-Series Branch Box Tee Distribution Pipe - Braze Connection between two branch boxes
PAC-493PI MXZ-Series Adapter 14 X38
PAC-SG76RJ-E MXZ-Series Adapter 38 X58
OPTIONAL ACCESSORIES CONTINUED ON NEXT PAGE
49 amp 66 applies to installations in which the outdoor unit is installed below indoor unit26 MITSUBISHI ELECTRIC
OPTIONAL ACCESSORIES (CONTINUED)
PART NUMBER USE WITH DESCRIPTION Control Options and Accessories
M21 JKO 307 M-Series Indoor Units Remote temperature sensor for M-Series indoor units
MAC-397IF-E
MAC-399IF-E
PAC-YU25HT
PAR-21 MM-G
M-Series INVERTER Units
M-Series INVERTER Units
SEZ-KD Indoor Units
Use with P-Series SEZ and for wired M-Series Controller
MA and contact terminal interface - Required to use PAR-21 MM wired wall mount controller with M-Series Systems
CMCN M-NET control adapter I Interface for Mr Slim M-Series MSYZ SEZ I MFZ
External Fan I Heater control relay adapter
Deluxe MA remote controller (Requires MAC-397IF-E for use with M-Series - MSYZ MFZ)
SEZ Wireless remote controller for SEZ units (Requires signal receiver PAR-SA9FA-E)PAR-FL32MA
PAR-SA9CA-E SEZ Wireless signal receiver for SEZ
3-pole disconnect switch 30A 600V turns off power between indoor and outdoor units shyM-SeriesTAZ-MS303
mounts in 2 X 4 utility box and requires standard single gang switch platecover - Low Ambient
ICM-326HM-2 M-Series Non-INVERTER units Low ambient head pressure controller MUZ-GE091215 IVIUZ-FE0912 SUZ-KD091215
Drain pan heaterMAC-640BH-U outdoor unit
MAC-641 BH-U MUZ-GE18 SUZ-KD18 outdoor unit Drain pan heater Filters
MAC-1415FT-E Anti-allergy enzyme filter
MAC-2300FT
MSZlMSY-D3036
Anti -allergy enzyme filter
MAC-308FT
MSYMSZ-GA24
MSZ-FD912 I FE0912 Platinum deodorizing filter
MAC-408FT-E Anti-allergy enzyme filter
MAC-415FT-E
M-Series Indoor Unit - GE09GE12GE15GE18
MFZ-KA Air Cleaning FilterAnti-Aliergy Enzyme Filter
MAC-418FT Anti-allergy enzyme filter
Filter Boxes
FBL1-1
MSZ- FD912 I FE091 2
FB Series Filter Box for SEZ-KD09NA Optional filter box with MERV 8 filters
FB Series Filter Box for SEZ-KD1215NAFBL1-2 Optional filter box with MERV 8 filters
and PEA-A 12M
FBL1-3 FB Series Filter Box for SEZ-KD18NA Optional filter box with MERV 8 filters
Pumps
SI1730-230 MSYZ - 30000 Btuh or greater Sauermann mini condensation pump 230V
S13100-115 MS-Series - non-INVERTER Sauermann mini condensation pump 115V
S13100-230 Sauermann mini condensation pump 230VMSYZ - Less than 30000 Btuh
Miscellaneous BRP-1 Bottom Return Plate for SEZ-KD09NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-2 Bottom Return Plate for SEZ-KD12KD15-NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-3 Bottom Return Plate for SEZ-KD18NA Converts low profile ducted indoor unit from rear return to bottom return
BV12FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderreglnsulated - 12
BV14FSI Use with any Mr Sl im multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 14
BV38FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 38
BV58FSI Use with any IVIr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 58
Condensing unit wall mounting brackets (set of 2) - 440 lb capacity painted steel NOTE CWMB1 IVIU and PU outdoor units Installer is responsible to select and provide suitable hardware and materials to insure proper
mount of bracket to wall
DSD-400N M-Series DiamondBacktrade Platform Stands MUZ-GE18 I MUZ(y)-03036 I
MAC-811DS Drain socket assemblySUZ-KA18
MAC-851DS MUZ-FD0912 Drain socket
MAC-855SG M-Series Air outlet guide
MAC-856SG M-Series Air outlet guide - MXZ-3B24 I 3B30 I 4B36 NA
MAC-860DS MUZ-GE091215 I MUZ-FE0912 Drain socket
MAC-889SG M-Series Air outlet guide- MXZ-2B20NA
MAC-S99SG M-Series Air outlet guide
PAC-SG59SG-E IVIXZ-SB4SNA Air outlet guide (1 piece) I MXZ-SB48NA (Requires 2 pieces)
PAC-SG61 DS-E MXZ-8B4SNA Drain socket - connector
PAC-SG64DP-E MXZ-SB48NA Drain pan
RCMKP1CB lVI-Series Wireless Lockdown bracket for remote controller
lILTRILlTE1 All M-Series Condensing unit mounting pad 16 x 36 x 3
MITSUBISHI ELECTRIC 27
MXZ-8 Series Port Adapter chart Port Adapter Unit Port
Combinations Required Size
MXZ-2B20NA-1
2-zone combinations wi NA
A 38 x both units s12K 14
1-MAC-A454JP-E B 38 x
6+15 14
9+15 1-MAC-A454JP-E
MXZ-3B24NA
All rated 2-zone combina-NA
A 12 x tions 14
All rated 3-zone combina-NA
B 38 x tions 14
C 38 x 14
MXZ-3B30NA
2-zone combinations wi at NA
A 12 x least one unit s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
9 + 24 14
3-zone combinations wi 1-MAC-A455JP-E
all units s12K
All other rated 3-zone NA
comb
MXZ-4B36NA
2-zone combinations wi at NA
A 12 x least one un it s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
6 + 24 14
1-MAC-A456JP-E D 38 x
9 + 24 14
3-zone combinations wi at NA
least two units s12K
3-zone combinations wi 1-MAC-A454JP-E
two units15K
6+6+24 or 6+9+24 1-MAC-A456JP-E
9+9+24 1-MAC-A456JP-E
4-zone combinations wi at 1-MAC-A455JP-E
least three units s12K
6+6+15+15 1-MAC-A454JP-E
6+6+15+15 1-MAC-A454JP-E
Note When using the Pu-A24BA PCA-A24KA or PEAD-A24AA two port adapter will be needed 1-MAC-A456JP-E (12 x 58) A port or 1-PACshySG76RJ-E (38 x 58) B C and D ports and 1-PAC493PI (14 x 38)
28 JMITSUBISHI ELECTRIC
6+6+246+9+24 6+12+249+9+24 9+12+24 or 12+12+24
6+15+24 6+18+24 9+15+249+18+24 12+15+24 or 12+18+24
15+15+24 15+18+24 or 18+18+24
15+24+24 or 18+24+24
Combinations of 4 or more zones
1-PAC-SG76RJ-E
See notes for application below
2
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
See notes for application below
PORT A =38 gas x 14 liquid
PORT B =38 gas x 14 liquid
PORT C =38 gas x 14 liquid
PORT A =38 gas x 14 liquid
PORT B = 38 gas x 14 liquid
PORT C = 38 gas x 14 liquid
PORT D =38 gas x 14 liquid
PORT E =12 gas x 14 liquid
Notes for application bull Check the lineset sizes for your indoor selected models bull Select the branch box or boxes needed for your application bull Compare indoor unit lineset sizes as compared to branch
box sizes bull Connect 15K + indoor units to the larger port on the
(PAC-AKA51 BC) bull Adapt lineset size with appropriate port adapter from
above list bull When using the PU-A24BA or PEAD-A24AA two port
adapter will be needed 1-MAC-A456JP-E (12 x 58) or 1-PAC-SG76RJ-E (38 x 58) and 1-PAC493PI (14 x 38)
-fv
~ DIAMONDBACKtrade
~) BV-Series Ball Valves Model numbers
BV14FFSI BV38FFSI
LISTED 891N REFRIGERANT
BV12FFSI VALVE bull Engineered for Mini-split andBV58FFSI
Multi-split HVAC Units bull Size available 14 38 12 58
bull Full Port Designbull Fully factory assembled bull Furnace brazed and pressure tested bull 700 PSIG Rated bull Each ball valve is equipped with Schraderreg Valve
for refrigerant service bull R-410A Compatible bull Design working pressure 700 PSIG bull Temperature range bull Flare Connections
-40 0 F to +3250 F (-400 C to + 1490
C) bull Forged brass body and seal cap bull Teflonreg seals and gaskets (no synthetic a-rings) bull Seal cap design permits valve operation without
removal of seal cap bull Suitable for use with R-11 R-22 R-123 R-125
R-134A R-236FA R-4202A R-402B R-404A R-407C R-410A R-500 R-502 and R-507
bull One year limited materials and workmanship
Part Number SAE Flare
A B C 0 E F
BV14FFSI 14 619 260 180 122 142 110
BV38FFSI 38 630 267 180 122 142 110
BV12FFSI 12 651 267 180 122 142 110
BV58FFSI 58 664 267 180 128 142 110
Ball valves come With an insulation piece warranty on Ball Valves
~ DIAMONDBACKtrade
~) Platform Stands
Lift the Mitsubishi Electric Comfort Solution
outdoor unit to new heights with our Diamondback Platform Stands
bull Easy to install
bull Available for all sizes of Mr Slim outdoor units
bull Color matched to the outdoor units
Model Number DSD-400N
L 15-34 x W 3-14 x H 3-14
r
)MITSUBISHI ELECTRIC 29
~ DIAMONDBACKtrade LINESETS
~~
Twin-Tube Lineset Insulation Design
bull Balanced outside diameter for uniform coiluncoil position stability
bull Minimum 12 insulation thickness on both tubes Diamondback Advantages include the following features
bull Quick efficient and economical field installation using factory applied Twin Tube insulation and flare connections with flare nuts mounted
bull Correct lengths for reducing waste and time
bull Quality consistency and economy
bull All Diamondback Lineset tubing is tested in accordance with ASTM E243
Filter Boxes
FB Series filter boxes are available in compatible sizes for all Mr Slim horizontal ducted indoor units
FBL 1 filter boxes include 1 thick pleated MERV 8 filter(s) installed Filters are tested in accordance with ANSIASHRAE Standard 522 and Rated Class 2 under UL Standard 900
The cabinet is constructed of non-insulated 20 gauge G-60 galvanized
FBL1-1 FB Series Filter Box for SEZ-KD09NA
FBL1-2 FB Series Filter Box for SEZ-KD12KD15-NA
FBL1-3 FB Series Filter Box for SEZ-KD18NA
steel with foam gasket and provides an air-tight connection to indoor unit and access door Gasket material complies with UL 723 requirements
A screw-through cabinet design for secure attachment to indoor unit and return connection in rear is easily field-converted to bottom return
30 MITSUBISHI ELECTRIC
bull
bull
bull
bull
bull
bull
LINE-HIDE~ Put a professional finish on air-conditioning
installations with an easy-to-install modular
system that beautifies exteriors and
protects Linesets drainlines and wiring
Can be use it indoors too Meets UL94v-O for interior applications
Has snap-on covers and a full selection of couplings elbows T-joints caps and more for any application complex or simple
Offers high-quality PVC with UV inhibitors for outdoor service in all weather conditions
Can be painted with most house paints to match exterior decors
Is not just for HVAC Hide any exterior cabling piping or wiring
Available in four sizes 2-14 3 4 and 6 tubes
Download a brochure at wwwline-hidecom to find out more information
For more information on our CITY MULTI VRF product line visit our website at wwwmitsubishiprocom
_lIJrUlllln ~ ~IIII1 fInll l
~
l bull bull
JMITSUBISHI ELECTRIC 31
Superior Operation
Advanced Control Technology Through Mitsubishi Electrics advanced controls technology the indoor unit is powered by the outdoor unit Three polarity sensitive wires plus a ground conductor run from the outdoor to the indoor unit providing both power and data communication An advanced wireless remote control is standard on all ductless models An optional wired on-the-wall controller is available for wallshymountedfloor-standing indoor units on INVERTER systems (also requires MAC-397 If adapter) while standard on SEZ -KD ducted units
Quiet Operation Do you hear that No Mitsubishi Electric systems operate at low sound levels our indoor units produce decibels barely at a whisper level Compare to other common sounds
Police siren 118 decibels Circular saw 107 decibels Vacuum cleaner 74 decibels Whisper-tone voice 35 decibels Library reading room 33 decibels Our Indoor Units 19 - 34 decibels (at low speed)
Did you hear that We hope you did
Warm Air No Drafts Our hot-start heat-pump technology provides warmth from the beginning The fan increases in speed as the coil is warmed reducing drafts so when you want warm air you get it
TEMP
88
System Control Mitsubishi Electric offers a comprehensive remote controller that can adjust temperature fan speed and more Choose from four modes COOL HEAT AUTO and DRY The controller also has a 12-hour ONOFF timer for one-button control of your personal comfort
Easy to Maintain With easily accessible filters little or no ductwork to clean and simple wiring between the indoor and outdoor units Mitsubishi Electric systems require minimal maintenance providing another level of convenience
Auto Changeover on Heat-Pump Systems (MUZISUZ outdoor units)
Our heat-pump systems sense whether a space needs cooling or heating and automatically switch modes as needed to maintain a consistent temperature You can set it and forget it
6 MITSUBISHI ELECTRIC
----
Hybrid Catechin pre-filters -- shy
- shy
Total Comfort
Additional Air Circulation With the WIDE VANE or SWING mode available on the MSY(Z)-GE24 D3036NA there is an option for ~~~~lQcnborizontal airflow directions that provide 150
0
of lateral airflow for greater conditioned air circulation
-- -----_ ~~ iii
~~---- 150
0
Multiple Filters for Cleaner Healthier Ai r Mitsubishi Electric indoor units use a sophisticated multi-part filter system to remove contaminants such as allergens viruses and bacteria from the air
A hybrid catechin pre-filter absorbs odorshycausing gases The hybrid-coating process makes the catechin filter washable and - if properly maintained with regular cleaningshyremains effective for up to 10 years
A Blue-enzyme anti-allergen filter reduces germs bacteria and viruses and helps trap dust pollens mites and other particles The filter uses an enzyme catalyst to help break down the sulfur atom bonds in allergen proteins transforming them into non-allergen proteins and effectively cleaning the air The filter should be cleaned regularly to maintain efficiency
STANDARD FILTER SYSTEM (USED IN MSYMSZmiddotGElFE18GND MODELS)
Front Panel - shy
Blue Enzyme anti-allergen filter
ENHANCED FILTER SYSTEM (USED IN MSZmiddotFE0912NA MODELS)
Programmable Comfort Smart Set featured on MSZ-GE systems provides the option to program multiple settings into one quick-press feature providing an additional level of comfort control
The POWERFUL mode (found on select systems) is available to cool or heat any desired space quickly by lowering the set temperature in cooling mode or raising the set temperature in heating mode both by T F In POWERFUL Mode the fan speed increases for 15 minshyutes then the system resumes all standard operations
Vl l
OQ
([) I
N o l ([)
Vl lt(n r-+ ([)
3 o lt ([)
s ([)
~ OJ l a --I ([) nr l o o ~
The high-efficiency MSZ-FE0912NA indoor units incorporate the standard Catechin filter plus two more filters for triple filtration The second filter a Blueshyenzyme filter made of a fibrous material renders allergens harmless by using enzymes The third filter a Platinum Catalyst Deodorizing filter has a ceramic surface absorption element and uses nanotechnology for high-power odor absorption Periodic cleaning following the recommended procedures will maintain filter effectiveness for up to two years This combination of filters provides a complete air-purifying system within the ultimate comfort solution
Front Panel - shy
Hybrid Catechin pre-filters
cJ shy Blue Enzyme anti-allergen filter
I
MITSUBISHI ELECTRIC 7
---- -- -- -
System Lineup RESIDENTIAL AND LIGHT COMMERCIAL SYSTEM MODELS AND CONTROLLERS
SINGLE
MSMU Air Conditioners
9500 to 12000 Btuh 13 SEER
bull Provides cooling-only system bull Non-INVERTER rotary compressor bull Ideal for spaces such as
bedrooms garages out-buildings video monitoring
- ROOM WALL-MOUNTED Ale (cooling only)
MSYMUY Air Conditioners
3800 to 34600 Btuh Capacity Range 151 - 21 SEER
~ -
bull Cooling-only system bull INVERTER-driven compressor bull WIDE VANE for a wider angle of airflow 150
0
from left to right (on GE24D30D36 models)
bull Ideal for spaces such as bedrooms garages large open rooms and bonus rooms
SINGLE-ROOM WALL-MOUNTED HEAT PUMPS (coo lin g and heatin g)
MSZMUZ Heat Pumps
3800 to 33200 Btuh Capacity Range
145 - 21 SEER 82 - 10 HSPF
bull Uses INVERTER-driven compressor bull Provides cooling and heating in a wide range
of capacities bull Offers a WIDE VANE for a wider angle of airflow 1500 from
left to right (on GE24D30D36 models) bull Ideal for applications in bedrooms home offices living
rooms dining rooms bonus rooms basements kitchens guard houses and more
Up to 26 SEER
MSZMUZ-FE0912NA High - Efficiency Heat Pumps
2800 to 25200 BtuH capacity range 202 - 26 SEER
10 - 106 HSPF
bull INVERTER-driven compressor bull Quiet operation as low as 19dB(A) bull i-seetrade Sensor technology bull Enhanced filtration system bull H2ireg high~heat capabilities (see page 12 amp13)
MSZ-FE09 is 100 percent at 50 F MSZ -FE12 is 92 percent at 50 F MSZ-FE18 is 100 percent at 50 F
SI NGLE-ROOM LOW WALL or FLOOR-STANDING UNIT (fo r use with MXZ -8)
New to our lineup is a Low Wall or Floor-Standing model that can fit into those once difficult installations
MFZ These units provide comfort in spaces such as (For use with MXZ-8 finished attics with knee walls basements with Outdoor Units only) low ceilings and glass-walled sunrooms
bull Provides cooling and heating in Mounted three inches above floor level these models a wide range of capacities provide conditioned air two vents and provide direct
bull Two outlet air vents front-panel access to the filter for easy cleaning The - Upper vent for cooling or heating MFZ can even be recessed in a wall during installation - Bottom vent for heating only provided proper clearances are maintained (Currently there is
bull Flush or recessed installation no 1 1 system with M FZ)
8 MITSUBISHI ELECTRIC
SING LE -ROOM HORIZONTAL- DUCTED HEAT PUMPS (coo lin g and heat ing)
WIR ELESS and W IR ED REMOTE C O NTRO LLERS
PAR-21 MAA Wireless remote controller Set Temperature
for wall-mounted and floor-standing indoor units ----- OnOff
Timer Menu Fan Speed
Fan Speed Filter
Test Run Set Time
CheckEcono Cool
Airflow UpDown Timer OnOff
Louver
Ventilation
Reset ---- shy Optional wired controller for the SEZ SLZ and MFZ indoor units (Optional controller for wall-mounted is
available and floor-standing indoor units Unit requires MAC-397 If adapter)
MHK1 WIRELESS REMOTE CONTROLLER Exclusive for INVERTER-driven Mr Slimreg Systems
Wireless Technology a SEZ and SLZ 11 systems with SUZ outdoor unit only
MIFH1
MITSUBISHI ELECTRIC 9
AMITSUBISHI ELECTRIC
l~ 1000
~r t ~~~O
MRCH1
rtj n-shy --1r-a-1-shy
Mode ------ -- shy
SEZSUZ If your customer is looking for discrete zoned comfort then a short-run ducted unit Heat Pumps is the right solution As a stand-alone system or connected to a MXZ multi-room
3800 to 19000 BtuH system the SEZ ducted units provide energy efficiency quiet operation and a Capacity Range compact design for quick easy instqllation hidden either in the ceiling or beneath
15 SEER _---~~mm the floor 175 - 10 HSPF
J ~ All of the 11 systems are ENERGY STAR certified and two systems qualify for
~ the federal tax credit These systems provide customers with an environmentally friendly indoor unit with a similar installation and familiar style
These SEZ indoor units also connect to MXZ multi-zone systems providing a wide array of installation options to best fit any application
SING LE -R OO M C EI LING -REC ESSED CASSETTE UN IT
SLZSUZ Heat Pumps The SLZ -KA ceiling-recessed units casette offer a wide
3100 to 22200 BtuH air-flow pattern for better air distribution in a less obtrusive Capacity Range style These indoor units can be used in 11 heat pump
15 - 16 SEER and multi-zone systems providing more options to your customers Install SLZs in a hard ceiling (with a access panel for
bull 96 HSPF
servicing) or in a 2x2 extra space drop ceiling With a built-in drainshylift mechanism for condensate removal and a 4 ventilation-air intake knockout option and multiple options for the 11 systems the SLZ
~ ~ handles a variety of installation needs
Two of the three 11 systems are ENERGY STAR qualified
Vl l
OQ
(I) I
N o l (I)
Vl ltV (I)
3 Vl r o ~ n OJ V (I)
1shy(MS-A12WA MODEL SHOWN)
MS COOLING-ONLY
IJON-INVERTER
Model Name Indoor Unit
Outdoor Unit
MS-A09WA MS-A12WA
MU-A09WA MU-A12WA
Cooling 1
Rated Capacity Btuh 9500 12000
Capacity Range Btuh
Total Input W 870 1070
Energy Efficiency SEER 13
Moisture Removal Pintsh 27 32 Sensible Heat Factor 068 070
Power Supply Phase Cycle Voltage 1 Phase 60Hz 115V 2
Voltage Indoor - Outdoor L1-N AC 115V Indoor - Outdoor N-2 AC 115V Indoor - Remote Controller Wireless Type
Indoor Unit
MCA A 12
Fan Motor FLA 095
Airilow (Lo-Med-Hi Poweriul)
DRY (CFM) 183-261-335-367 222-286-406-446
WET (CFM) 162-233-300-328 198-254-363-399
Sound Pressure Level (Lo-Med-Hi)
dB(A) 26-32-40-42 33-38-45
External Finish Color Munsell No 1OY 9202
Dimension Unit
W In 30-1116
0 In 8-14
H In 11-34
Weight Unit Lbs 23
Field Drainpipe Size 00 In 58
Outdoor Unit
MCA A 14 16
MOCP (Time Delay) A 15 20
Fan Motor FLA 063 093
Compressor
Model (Type) Single Rotary
RLA 93 1082
LRA 47 56
Airilow CFM 1083 1327
Refrigerant Control Capillary Tube
Sound Pressure Level (Cooling) 1
dB(A) 47 52
External Finish Color Munsell No 3Y 7811
Dimensions
W In 31-12 33-716
0 In 11-14 11-716
H In 21-58 23-1316
Weight Lbs 78 96
Remote Controller Type Wireless Remote
Refrigerant
Type R410A Charge Lbs Oz 25 31
Oil Type (FI Oz) NE022 (108)
Refrigerant Pipe
Gas Side 00 In 38 12
Liquid Side 00 14
Height Difference (Max) Ft 35
Length (Max) 65
Connection Method IndoorOutdoor FlaredFlared
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling) - Indoor DB 800 F(270 e) WB 670 F(190 e) Outdoor DB 950 F(350 e) WB 750 F(240 e) 2 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice
LlIVIITED WARRANTY ISeven-year warranty on compressor Five-year warranty on parts
10 MITSUBISHI ELECTRIC
I
R ---I Vl
J(MSY-GE1 7NA MODEL SHOWN) OQ
MSY COOLI NG-ON LY (CO NT ) CD N o J CD
s Vl OJ J
Cooling 1 0shy
s Vl -lt Vl
~~~~~-=~------~~--------------------------~~~~----------------------------~ jVoltage
205-272-335shy145-170-237 -321-399
420-533 170-237 -300shy
385-498
26-32-38-44-49Indoor Unit
Outdoor Unit
194-240-304shy385-498
28-33-38-44-49
388-469-628-738
347-420-562-661
34-41-49-53
CD n 3-i n OJ 0389-639-848 o J350-576-763 V)
32-42-49
2 9 43Refrigerant
FV50S (040) NE022 (295)
Refrigerant Pipe
Refrigerant Pipe Length
Connection IndoorOutdoor FlaredFlared
Method
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling) - Indoor DB 80deg F(27deg e) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice
LIMITED WARRANTY ISeven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 11
~ (MSZ-FE12NA MODEL SHOWN)
MSZ HEAT PUMP TAX
CREDIT
Model Name
Cooling 1
Indoor Unit Outdoor Unit
Rated Capacity Btuh
MSZ-GE09NA MUZ-GE09NA
9000
MSZ-FE09NA HshyMUZ-FE09NA bull
9000
MSZ-GE12NA MUZ-GE12NA
12000
MSZ-FE12NA MUZ-FE12NA
12000
H-bull MSZ-G MUZ-G
14000
Capacity Range Btuh 3800-12200 2800-9000 3800-13600 2800-12000 3100-18200
Total Input W 660 (205-1200) 580 (160-650) 960 (205-1300) 930 (160-960) 1080 (160-2000)
Energy Efficiency SEER 21 26 205 23 21
Moisture Removal Pintsh 15 21 25 29 27
Sensible Heat Factor 082 076 074 073 080
Heating at 47deg F 2
Rated Capacity Btuh 10900 10900 14400 13600 18000
Capacity Range Btuh 4500-14100 3000-18000 5500-18100 3000-21000 4800-20900
Total Input W 760 (255-1200) 710 (150-2250) 1170 (340-1660) 950 (150-2250) 1600 (270-2010) HSPF (IV) BtuhlW 10 106 10
Heating at 17deg F3 Rated Capacity Btuh 6600 6700 8800 8300 11300 Rated Total Input W 700 650 900 800 1150 Maximum Capacity Btuh 8700 12500 11200 13600 15900
Heating at 5deg F Maximum Capacity Btuh 7061 10900 9194 12500 13022
Power Supply Phase Cycle Voltage 1-phase 60Hz 208 230V 4
Voltage
Indoor - Outdoor S1 - S2 AC 208 230V
Indoor - Outdoor S2 - S3 DC12-24V
Indoor - Remote Controller Wireless Type (Optional Wired Controller DC 12V)
Indoor Unit
MCA A 10
Fan Motor FLA 076
Airflow at Cooling (Lo-Med-Hi-Super HI-Powerful) 1
DRY (CFM) 145-170-237-321-399 162-226-339-381 145-170-237-321-399 162-226-381-410 205-272-335-420-533
WET (CFM) 109-134-201-286-364 144-202-307-343 109-134-201-286-364 144-202-350-367 170-237-300-385-498
Airflow at Heating (Lo-Med-Hi-Super HI-Powerful) 2
WET (CFM) 145-170-237-321-406 166-240-367-381 145-170-237-321-406 166-240-399-420 205-247 -304-367-463
Sound Pressure Level at Cooling (Lo-Med-Hi-Super HI-Powerful) 1
dB(A) 19-22-30-37-43 22-31-39-42 19-22-30-37-45 22-33-43-45 26-32-38-44-49
Sound Pressure Level at Heating (Lo-Med-Hi-Super HI-Powerful) 2
dB(A) 19-22-30-37-43 22-31-40-42 19-22-30-37-43 22-33-43-44 26-30-35-40-46
External Finish Color Munsell No 10Y 92 I 02
Dimension Unit
Wln 31-716 31-38 31-716 31-38 31-716
0 In 9-118 10-18 9-18 10-18 9-18
H In 11-58
Weight Unit Lbs 22 27 22 27 22
Field Drainpipe Size 00 In 58
Outdoor Unit
MCA A 12
MOCP A 15
Fan Motor FLA 050 056 050 056 050
Compressor
lVIodel (Type) DC INVERTER-driven DC INVERTER-driven Twin
Rotary DC INVERTER-driven DC IIWERTER-driven Twin Rotary
RLA 66 86 66 86 74
LRA 82 108 82 108 93
Airflow (CoolingHeating) CFM 11511225 1102 11187 12291172 1102 11187 12431229 Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(A) 46 48 49 48 49
Sound Pressure Level at Heating 2 dB(A) 50 49 51 49 51
External Finish Color Munsell No 3Y 78 11
Dimensions
Wln 31-12
0 In 11-114
H In 21-58
Weight Lbs 66 80 77 80
Remote Controller Type Wireless Remote (Optional Wired Controller)
Refrigerant
Type R410A
Charge Lbs Oz 112 29
Oil Type (fl oz) NE022 (108) NE022 (152)
Refrigerant Pipe Gas Side 00 In 38 12
Liquid Side 00 In 14 14
Refrigerant Pipe Length Height Difference (Max) Ft 40
Length (Max) Ft 65 I
Connection Method IndoorOutdoor FlaredFlared
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg e) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg e) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg e) Outdoor DB 47deg F(8deg e) WB 43deg F(6deg e) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg e) Outdoor DB 17deg F(-8deg e) WB 15deg F(-9deg e) 4 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice
12 +MITSUBISHI ELECTRIC LIMITED WARRANTY ISeven-year warranty on compressor Five-year warranty on parts
- shy(MSY(Z)-D30NA MODEL SHOWN)
Vl J
09 (I)
I
N o J (I)
s Vl N Vl
-0 (I) n 31 n OJ 0 o J V)
Model Name Indoor Unit MSZ-GE18NA MSZ-FE18N MSZ-GE24NA MSZ-D30NA MSZ-D36NA
Outdoor Unit MUZ-GE18NA MUZ-FE18rK MUZ-GE24NA MUZ-D30NA MUZ-D36NA Rated Capacity Btuh 17200 18000 22500 30700 33200
Capacity Range Btuh 3700-18700 8200-25200 8200-31400 9800-30700 9800-33200
Total Input W 1640 (240-2070) 1270 (570-2280) 1800 (570- 3580) 3850 (620-3850) 4360 (620-4360) Cooling 1
Energy Efficiency SEER 192 202 190 145
Moisture Removal Pintsh 46 27 27 99 11 3
Sensible Heat Factor 071 084 075 064 062
Rated Capacity Btuh 21600 21600 27600 32600 35200
Capacity Range Btuh 3500-25200 7500-29700 7500-36900 8700-34000 8700-36000 Heating at 47deg F 2
Total Input W 1900 (230-2680) 1540 (520-2240) 2340 (520- 3650) 3360 (520-3600) 3840 (520-4100)
HSPF (Region IV) BtuhIW 10 103 10 82
Rated Capacity Btuh 13400 11700 16000 19500 21800
Heating at 17deg F 3 Total Input W 1450 2180 3290 2400 2820
Maximum Capacity Btuh 17200 19300 24600 20800 22800 Heating at 5deg F
Maximum Capacity Btuh 13562 21 600 21160 16305 19090
Power Supply Phase Cycle Voltage 1 Phase 60Hz 208230V 4
Indoor - Outdoor S1-S2 AC 208 230V Voltage Indoor - Outdoor S2-S3 DC12-24
Indoor - Remote Controller Wireless Type (Optional Wired Controller DC12V) MCA A 10 Fan Motor FLA 076
DRY (CFM) 230-275-339-420-533 388-469-628-738 388-469-628-738 389-639-848 Airilow (Cool) (Lo-Med-Hi-Super HI-Poweriul) 1
WET (CFM) 194-240-304-385-498 347-420-562-661 347-420-562-661 350-576-763
Airilow (Heat) (Lo-Med-Hi-Super HI-Poweriul) 2 DRY (CFM) 230-275-339-431-512 388-469-628-738 388-469-628-738 445-639-848
Sound Pressure Level (Cooling) (Lo-Med-Hi-Super 28-33-38-44-49 34-41-49-53 34-41-49-53 32-42-49
HI-Poweriul) 1
Sound Pressure Level (Heating) (Lo-Med-Hi-Super dB(A)
Indoor Unit 28-33-38-43-48 32-41-49-52 32-41-49-52 34-42-49-49HI-Poweriul) 2
External Finish Color Munsell No 1 OY 9202
W In 31-716 43-516 46-116
Dimension Unit D In 9-18 9-38 11-58
H In 11-5 8 12-1316 14-38
Weight Unit Lbs 22 37 40
Field Drainpipe Size OD In 58
MCA A 14 171 21
MOCP A 15 20 25
Fan Motor FLA 093
Model (Type) DC INVERTER-driven Twin Rotary
Compressor RLA 100 129 16
LRA 125 161 20
Airilow CFM 1730 1659 17691 701 1941
Outdoor Unit Refrigerant Control Linear Ex~ansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(A) 54 55 56
Sound Pressure Level at Heating 2 dB(A) 56 55 57
External Finish Color Munsell No 3Y 7811
W In 33-116
Dimensions D In 13
H In 33-716 34-58 33-716
Weight Lbs 119 141
Remote Controller Type Wireless Remote (Optional Wired Controller)
Type R410A
Refrigerant Charge Lbs Oz 3 7 43 410
Oil Type (FI Oz) NE022 (152) FV50S (135) NE022 (29)
Gas Side OD 12 58In
Refrigerant Pipe Liquid Side OD 14 38
Height Difference (Max) 50
Length (Max) Ft
100 I Connection
Mpthon IndoorOutdoor Flared Flared
NOTESTest conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg C) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F (24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F(6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 17deg F(-8deg C) WB 15deg F(-9deg C) 4 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice LIMITED WARRANTY ISeven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 13
(SEZ-KD12NA MODEL SHOWN)
SEZ HEAT PUMP TAX
CREDIT
Model Name Indoor Unit SEZ-KD09NA4 SEZ-KD12NA4 SEZ-KD15NA4 SEZ-KD18NA4
Outdoor Unit SUZ-KA09NA SUZ-KA12NA SUZ-KA15NA SUZ-KA18NA Rated Capacity Btuh 8100 11500 14100 17200
Capacity Range Btuh 3800-10900 3800-13300 3800-17000 3800-19000
Cooling 1 Total Input W 670 920 1170 1380
Energy Efficiency SEER 15 16 155 175 Moisture Removal Pintsh 15 24 26 34 Sensible Heat Factor 080 076 080 079
Rated Capacity Btuh 10900 13600 18000 21600
Heating at 4YO F 2 Capacity Range Btuh 4800-14100 4800-16400 4800-21100 4800-24900
Total Input W 1020 1140 1500 1700 HSPF(lV) BtuhIW 100 Rated Capacity Btuh 6700 9000 11900 13100
Heating at 1 yo F 3 Rated Total Input W 810 920 1200 1350 Maximum Capacity Btuh 7300 9800 13700 15000
Power Supply Phase Cycle Voltage 1 Phase 60Hz 208 230V 4 Indoor - Outdoor S1 - S2 AC 208-230V
Voltage Indoor - Outdoor S2 - S3 DC 12-24V Indoor - Remote Controller See optional accessories chart (pg 26 and 27) MCA A 1 Fan Motor FLA 051 057 074
Airflow (Lo-Med-Hi) DRY (CFM) 194-247-317 247-317-388 353-441-529 423-529-635
WET (CFM) 174-222-285 222-285-349 317 -396-4 76 381-476-572 External Static Pressure 3 In wG 002-006-014-020 Sound Pressure Level dB(A) 23-26-30 23-28-33 30-34-37 30-34-38
Indoor Unit External Finish Galvanized-Steel Sheets
W In 31-18 39 46-78
Dimension Unit D In 27-916
H In 7-78
Weight Unit Lbs 42 50 54 62 Field Drainpipe Size 00 In 1-14
MCA A 12 14
MOCP A 15 Fan Motor FLA 050 093
Model DC Inverter DC Inverter Twin Rotary
I (Type)Compressor
RLA 66 74 10
LRA 82 93 125
Airflow (CoolingHeating) CFM 11511225 12291172 1 2431 229 17301659
Outdoor Unit Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(A) 46 49 54 Sound Pressure Level at Heating 2 dB(A) 50 51 56
External Finish Color Munsell No 3Y 7811
W In 31-12 33-16
Dimensions D In 11-14 13
H In 21-58 33-716
Weight Lbs 66 77 80 119 Remote Controller Type See optional accessories chart (pg 26 and 27)
Type R410A
Refrigerant Charge Lbs Oz 116 2 9
Type (fl Oil
oz) NE022 (108)
Refrigerant Pipe Gas Side OD In 38 Liquid Side 00 In 14
Refrigerant Pipe Height Difference (Max) Ft 40 Length Length (Max) Ft 65
Connection IndoorOutdoor FlaredFlared
Method
316
NE022 (152)
12
50
100
I
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg C) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F(8deg C) WB 43deg F(6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 17deg F(-8deg C) WB 15deg F(-9deg C) 4 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
14 MITSUBISHI ELECTRIC
SEZ STATIC PERFORMANCE CURVES (SEZ-KD12NA4 MODEL SHOWN)
SEZ-KD09NA4 SEZ-KD09NA4 (External static pressure O06[inwG]) 208230V 60Hz
[020] V L
5 [016
~l [0 12
]
SEZ-KD09NA4
~ ltij
~ [008
Jj
]
]
[004J ~
V V Middle
Low
V
19h
Rated point
1
o [141] [176J 1212) )247] [282J [318]
Airll ow rat e [CFM)
SEZ-KD12NA4 (External static pressure O06[inwG]) 208230V 60Hz
[020
5 [016
]
]
[353J
Limit
]
~ V
~ [ [0 12
u ltijJ[008
[004
]
_V ]~ Low
V
k-iddle
Rated POint
o [212) [247] [2 82] [318] [353] [388]
Airtlow rate [C FM]
SEZ-KD1SNA4 (External static pressure O06[inwGl) 208230V 60Hz
[424)
1020]
5 [016
~ ~ [012
~ ltij
~ [008
Jj
J
)
]
[004 ]
o
VV V [ Low
VV
vV High
Middle
I Rated point
[282] [318) [353] [388] [424] [459] [494] [530] [565J
Airllow rat e [CFM]
SEZ-KD18NA4 (External static pressure O06[inwG]) 208230V 60Hz
50 10 20]
] 40
5 [016
s 30 [ (012 )
ltij 20 ~ [008 )~Jj
10 [004]
V
Low
v Limit
rIV High
V [ Middle
~
1
Rated point
f318) [353) [388] [424] [459] [494] [530] [565] [600] [636] [671 )
Airllow rate [CFM]
(External static pressure O14[inwG]) 208230V 60Hz 80
[0 32
70 [028
5 60 [024
20 [0 08
10 [004
]
]
J
]
]
J
]V
]
U~it
V
k
High
~V Rated POI~1 V Middle Low
~
o [141] [1 76] 12121 )247J [282] [318]
Airtlow rate [CFM)
SEZ-KD12NA4 (External stat ic pressure O14[inwG]) 208230V 60Hz
[032]
[028J
5
[353]
J
~ [024
-~ [020] V-is
J V Il Hi9h Rated point
[016
~ ]
V V1 Middle
~ [012
[008]~
[004)
o [212)
[247)
SEZ-KD1SNA4
Low r
[282] [31 8) [353]
Airllow rale [CFM]
[388]
(External static pressure O14(inwG]) 208230V 60Hz
[032J
[424
]
2 V[028
5 [024]
V-i
] V High i [020
] K
Middle Rated point [0 16
g ]
~ -
QJj [0 12
J Low
[008
] I
~
[004
o [282J [318) [353J [388J [424) [459] [4 94] [530) [565)
Airt low rate [CFM]
SEZ-KD18NA4 (External statiC pressure O14(inwG]) 208230V 60Hz
1032
1028
~ 1024
-~ [0 20
is (0 16 ltij E ~ [012
(008
(004
o
I
]
]
)
]
)vlt ]
]
~ V
VV
Low
Limit
V
Ji9h
Middle l
Rated point
1 t
1
~ [318] [353] [388] [424] [459) [4 94] [530) [565) [600] [636] [671)
Airllow rate [CFM]
(External static pressure O20(inwG]) 208230V 60Hz
[032 ]
[028 J
5 [024
~ [020
is [016
1 [012Jj
[008
[004
J
]
]
] )
]
V Low
umz V High
~V
Rated point
Middle
1
[141] [176] [212) [247) [282) [318) [353J
Airtlow rat e [CFM]
SEZ-KD12NA4 (External static pressure O20(inwG]) 208230V 60H z
[032 ] LLimit
)
[0 28
5 ]
V
[024 -~ [020] V Rated point
Highis ~
) V
bull Middle
]~V I
[016
~ ~ [012
] Low
[008
]
[0 04
o [212) [247] [282] [318] [353] [388] [424]
Airllow rate [CFM]
SEZ-KD1SNA4 (External static pressure O20(inwG]) 208230V 60Hz
80 [032 ]
70 [0 28
~ [ O~~ -
ltij
E 30 ~ [0 12
20 [008
10 [004
o
)
J
]
]
JV
J
J
Limit V
LV High
V ~
K Rated point
Middle
VV 1gt
Low
I-
~ [282) [318) (353] (388) (424) 1459] [494] 15301 [565)
Airtlow rate [CFM]
SEZ-KD18NA4 (External static pressure O20[inwG]) 208230V 60Hz
[032
[028
~ [024sect
I [020
~ [016
~ Jj [0 12
[008
[004
o
]
)
]
]
]
~ )
]
]
1V
V 1
V
Low
1 limit
~~~ I ~~ High
~ R~ted pOini
Middle
1 1 -
[31 8) [353] [388] [424) [459] [494] [530] (565) [600] (636) [671J
Airllow rate [CFM)
Vl ~ ca (I)
I
N o ~ (I)
Vl m N Vl
-0 (I) n 3-i n QJ ~ o ~ tn
Note ESP 20S230V 60 Hz See manual for Static Performance Curve including 002 in WG
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts ~MITSUBISH[ ELECTRIC 15
SLZ HEAT PUMP (SLZ-KA12NA MODEL SHOWN)
Model Name Indoor Unit SLZ-KA09NA SLZ-KA12NA SLZ-KA15NA
Outdoor Unit SUZ-KA09NA SUZ-KA12NA SUZ-KA15NA Rated Capacity Btuh 8400 11100 15000
Capacity Range Btuh 3100-10900 3100-13300 3100-22200
Cooling 1 Total Input W 700 920 1460
Energy Efficiency SEER 15 154 16 Moisture Removal Pintsh 12 23 45 Sensible Heat Factor 080 076 080
Rated Capacity Btuh 10900 13 600 18000
Heating at 4r F 2 Capacity Range Btuh 3100-14100 3100-17100 3100-17100 Total Input W 930 1180 1950 HSPF (IV) BtuhIW 96 Rated Capacity Btuh 6200 8300 10200
Heating at 17deg F 3 Rated Total Input W 740 930 1310 Maximum Capacity Btuh 8300 10200 12000
Power Supply Phase Cycle Voltage 1 Phase 60Hz 208 230V 4 Indoor - Outdoor S1 - S2 AC 208-230V
Voltage Indoor - Outdoor S2 - S3 DC 12-24V
Indoor - Remote Controller See optional accessories chart (pg 26 and 27) MCA A 1 Fan Motor FLA 023 028 028
Airflow (Lo-Med-Hi) DRY (CFM) 280-320-350 280-320-390 280-320-390
WET (CFM) 250-290-320 250-290-350 250-290-350
Sound Pressure Level dB(Al 29-32-38 30-34-39 31-35-40
Indoor Unit External Finish Galvanized-Steel Sheets Grille Munsell 64Y 8904
W In 22-7 16 (25-58)
Dimension Unit (Grille) D In 22-716 (25-58
H In 8-316 (1316)
Weight Unit (Grille) Lbs 36 (7) Field Drainpipe Size 0 0 In 1-14 MCA A 12 MOCP A 15 Fan Motor FLA 050
Model (Type) DC INVERTER-driven DC INVERTER-driven
Compressor RLA 66
LRA 82
Airflow (CoolingHeating) CFM 11511225 1 229 1 172
Outdoor Unit Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(AJ 46 49 Sound Pressure Level at Heating 2 dB(AJ 50 51
External Finish Color Munsell No 3Y 781 1
W In 31 shy12
Dimensions 0 In 11-14
H In 21-58
Weight Lbs 66 77
~e R410A
Refrigerant Charge Lbs Oz 1 16
Oil Type (fl oz) NE022 108)
Refrigerant Pipe Gas Side 0 0 In 38 Liquid Side 00 In 14
Height Difference (Max) Ft 40 Refrigerant Pipe Length
Length (Max) Ft 65
Connection Method IndoorOutdoor FlaredFlared
29
Twin Rotary 74
93
12431 229
80
NE022 l152) 12
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg C) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F(8deg C) WB 43deg F(6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 17deg F(-8deg C) WB 15deg F(-9deg C) 4 Indoor units receive power from outdoor units through field-supplied interconnectedwiring Specifications are subject to change without notice
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
16 MITSUBISHI ELECTRIC
MHK1 WIRELESS REMOTE CONTROLLER KIT Exclusive for INVERTER-driven Mr Slimreg Systems VlWireless Technology a J
JMITSUBISHI ELECTRIC
Wireless Receiver
MHK1 Kit includes
09 mMRCH1 WIRELESS REMOTE CONTROLLER I Nbull Backlit easy-to-read display o
bull Dual setpoint control with system changeover J m
bull Enabled with RedLlNKTM reliability
bull Compatible with MCCH1 Vl Portable Central Controller m
N bull Installs Anywhere Vl
MFH1 WIRELESS RECEIVER N Vlbull Required for MRCH1 Wireless
CRemote Controller m bull Enabled with RedLiNK reliability n
31 n OJ o J en
SEZ and SLZ 11 systems with SUZ outdoor unit
Function Description
ONOFF OnOff operation for a single indoor unit
Operation Mode Cool I Drying I Auto I Heat I Fan only Available operation modes dependant on connected system
Temperature Setting Set temperature from 50degF - 8rF depending on operation mode and connected system
System Changeover Deadband Value 2-8degF
Schedule Operation 5-25-1-1
Fan Speed Setting HiMid-2Mid-1 IlowlAuto Available fan speed settings dependant on connected system
Air Flow Direction Setting Air flow angles 100deg - 80deg - 60deg - 40deg and oscilate Available air flow direction settings dependant on connected system
PermitProhibit Function Individual prohibit operations for each remote controller function (ONI OFF Set Temperature and Operation Mode)
Space Temperature Displays the measured space temperature
Error Indication Displays error code
Display Outside Temperature and Humidity
Requires optional MOS1 Outside Air Sensor
Dimensions - ryv x D x H) Remote Controller 5-316 x 1-12 x 3-916 Receiver 3-14 x 1-516 x 6-716
Operating Ambient Temperature Remote Controller 32 - 120degF Receiver -40 - 165degF
Operating Ambient Humidity Remote Controller 5 - 90 RH (non-condensing) Receiver 5 - 90 RH (non-condensing)
Power Supply 2 AA batteries
MRCH1 MIFH1 MRC1
Wireless Wall-Mounted Remote Controllers Wireless Receiver Cable
Accessories MCCH1 MOS1
Portable Central Controllers Outside Air Sensor
MITSUBISHI ELECTRIC 17
MULTIPLE ROOMS WITH INDIVIDUAL CONTROL FROM A SINGLE SYSTEM Enjoy ideal levels of comfort in the rooms you use most with our multi-room system Each room (zone) operates independently People in different rooms - the kitchen master bedroom or living room - can enjoy temperature settings that make each of them most comfortable
If you re looking for a complete comfort solution for several different rooms the MXZ multi-room system is the right choice The system is flexible enough to conform to a particular cooling and heating need and offers numerous different indoor unit combinations In addition up to eight indoor units can be connected to one outdoor unit Now with a SEZ horizontal ducted unit and a MFZ floorshystanding unit homeowners can enjoy an even greater range of zoning options provided by an MXZ system
An MXZ multi-room system is an excellent choice for supplementing capacity to a current system conditioning newly furnished spaces or new additions and replacing a system within a home Homeowners can also benefit from lower energy costs year-round while staying comfortable thanks to Mitsubishi Electrics energy-efficient technologies that are a part of every system that we make
To add to the level of energy efficiency the MXZ -2B20NA and MXZ -3B24NA systems qualify for both ENERGY STARreg and the federal tax credit (See details on page 21 for applicable indoor unit combinations)
At right a single level home with several system types represented (For illustrative purposes only)
MFZ Floor-Standing Indoor Units for MXZ Heat Pump Systems
Floor-standing indoor unit mounts three inches above the floor and has front panel access to the filter for ease of cleaning
The MFZ units provide energy-efficient solutions to provide personalized comfort for difficult areas that may be smaller or dont have usable space on the walls
MFZ units on MXZ systems include the following features bull Top and bottom discharge vanes bull Hot-start technology bull Quiet operation bull Wireless remote control (optional wall-mounted controller)
18 MITSUBISHI ELECTRIC
MSZ Wall-Mounted Indoor Units for MXZ Heat Pump Systems
Providing a wide range of cooling and heating capacities each wall-mounted indoor unit mounts high on a wall and connects to a branch box or the outdoor unit by a refrigerant line run via a 3 hole The MSZ units provide highly efficient solutions to cooling and heating needs and provide personalized comfort for the individual zones in which they are installed
MSZ units on MXZ systems include the following features bull Sleek flat panel design bull Hot-start technology bull Quiet operation bull i-seeM sensor technology (MSZ-FE0912NA models only) bull Enhanced filtration system (MSZ-FE0912NA models only) bull Wireless remote control (optional wired wall-mounted controller)
SLZ Ceiling-Recessed Indoor Units for MXZ Heat Pump Systems
The new SLZ-KA ceiling casette systems offer a wide air-flow pattern for better air distribution
offered to your customers Installation can be done in a hard ceiling (with a access panel for servicing) or placed into a 2x2 drop ceiling With a built-in drain lift mechanism for condensate
removal and a 4 ventilation air intake knockout option the SLZ is ready to handle a variety of installation needs
SLZ units on MXZ systems include the following features bull Wide air-flow pattern for better air distibution bull 4 ventillation air intake knockout bull Built-in condensate lift mechanism bull Wireless RedLlNKTM remote controller
SEZ Horizontal Ducted Indoor Units for MXZ Heat Pump Systems
SEZ ducted units can provide split air-conditioning system advantages with the added benefit of being concealed to provide virtually no visual footprint within the conditioned space other than a register and grille for the air to flow With the use of short run ductwork these units can provide comfort to a single room that needs air dispersed evenly throughout the space unusually shaped rooms and adjacent rooms
The SEZ unit on MXZ systems include the fOllvowin fatures _
g~e~~~~==Zl[bull Concealed design for short-run ductwork bull Quiet operation bull Built-in condensate lift mechanism
JMITSUBISHI ELECTRIC 19
s c t
I
N o J ro o ltro ~ ro ~
DIAMOND COMFORT MXZ MULTI-ZONE SYSTEMS MXZ-B Series multi-zone systems provide personalized comfort control and energy efficiency in up to eight rooms with only a single outdoor unit The MXZ-B Series system features include
bull Individual zone control bull Mix and match flexibility of indoor unit styles and combinations bull A wide range of indoor unit capacities that match the room size and requirements bull Flexible design options to tackle the most challenging multi-room installations bull Efficient systems including three systems [mxz series] that meet energy starltID and
federal tax credit requirements bull Simple quick and cost-effective installation keeps install costs down on new construction
and disruption to a minimum on renovations and refits
Efficiency and performance ratings depend on the number style and capacity of the indoor units installed with each Multi-Zone System
MXZ -2 B20 NA - 1 (2 1 ) MXZ -3 B24 NA (2 13 1) Ou tdoo r Unit Outdoor Uni t
MSZ-GE09NA Indoor Units
SEZ-KD12NA Indoor Unit
MSZ- GE06NA
~~~~li
(At least two indoor units MSZ-GE06NAIndoor Unit must be installed) Indoor Unit
(Two indoor units must be installed )
MXZ -3 B30 NA (2 1 3 1) Outdoor Unit
SEZ-KD12NA Indoor Unit
~~~i
(At least two indoor units MSZ-GE06NA must be installed)
Indoor Unit ~
MFZ- KD12NA Indoor Unit
MXZ-8B48NA (2 1-8 1) Outdoor Unit
(At least two indoor units
must be installed)
(At least two indoor units must be installed)
MFZ-KD09NA Indoor Units
MSZ-GE09NA Indoor Units
SEZ-KD12NA Indoor Unit
MSZ INDOOR UNIT
MSZ-FE18NA
PEAD HORIZONTAL -DUCTED INDOOR UNIT
PEAD-A24AA
MSZ INDOOR UNIT SEZ HORIZONTAL-DUCTED MSZ-FE18NA
INDOOR UNIT MFZ FLOOR-STANDING SEZ-KD18NA INDOOR UNIT
MFZ-KA12NA
20 AMITSUBISHI ELECTRIC
MULTI-ROOM MXZ-8 INVERTER HEAT PUMP R
Model Name Outdoor Unit MXZ-2B20NA-1 5 MXZ-3B24NA 6 MXZ-3B30NA MXZ-4B36NA 7
Indoor Unit
Cooling 1 Non-ductedl Ducted
Rated Capacity Btuh 1800020000 2200023600 28400127400 3540034400
Capacity Range Btuh 7800-20000 12600-25500 12600-28400 12600-36400
Total Input W 2190 (630-219QL 2460 (1000-2950) 3330 l1 000-3330) 3 940 (1 000-4020)
Heating at 4JO F 2 Non-ductedl Ducted
Rated Capacity Btuh 2200022000 2500024600 2860027600 3600034400
Capacity Range Btuh 8500-25500 11400-30600 11 400-36000 11400-43000
Total Input W 2620 (520-2620) 1900 (740-2600) 2220 (740-2820) 3100 (740-3940)
Heating at 1JO F 3 Non-ductedl Ducted
Rated Capacity Btuh 1250012500 1400014000 1600015100 2220020300
Rated Total Input W 13501430 13801570 21202 140 24302340
Maximum Capacity Btu h 1450014500 1880017000 1880018000 2460025400
Maximum Total Inl2ut W 15001590 21202230 21202140 33403450
Power Supply Phase Cycle Voltage 1-phase 60Hz 2081 230V 8
Voltage Indoor shy Outdoor S1 - S2 AC 2081 230V
Indoor shy Outdoor S2 - S3 DC12-24V
Outdoor Unit 4
MCA A 15 19
MOCP A 20
Fan Motor FLA 096 093
Compressor
Model (Type)
DC INVERTER-driven Twin Rotary
RLA 101 11 144
LRA 15
Airflow (CoolingHeating) CFM 14851 640 20681605 13651605 20682068
Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1
dB(A) 49 54 49 54
Sound Pressure Level at Heating 2
dB(A) 51 49 57
External Finish Color Munsell No 30Y 781 1
Dimensions
W In 33-116 35-716
D In 13 12-58
H In 27-1516 35-7116
Weight Lbs 130 150 153
Indoor Unit No of Units 2 23 23 234
Remote Controller Type Associated with the Indoor Unit
Refrigerant
Type R410A
Charge Lbs Oz 515 7 11 813
Oil Type (fl oz)
NE022 (237) NE022 (294)
Refrigerant Pipe Gas Side 00 In AB 38 A 12 BC 38 A 12 BCD 38
Liquid Side 00 In 14
Refrigerant Pipe Length Height Difference (Max) Ft 4933 9
Length (Max) Ft 164 (A+B) 230 (A+B+C) 230 (A+B+C+D)
Connection Method IndoorOutdoor FlaredlFlared
Compatible with the MSZ-A MSZ-GA MSZ-FD MSZ-FE MSZ-GE MFZ-KA and SEZ-KD series indoor units (PLA-18 amp PCA-24 on the MXZ-MXZ-3B PLA-24 amp PCA-24 on the MXZ-4B)
NOTES Test conditions are based on AHRI 210240 One indoor unit is turned off during low-speed testing under the new test conditions Systems actually exhibit higher energy efficiencies during normal operation
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F (35deg C) WB 75deg F (24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F (6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 600 F (160 C) Outdoor DB 17deg F (_80 C) WB 150 F (_90 C) 4 Refer to pages 12 and 13 for Indoor Unit specifications 5 Data from combination of two Indoor Units 9000 Btuh (non-ducted) or one 9000 Btuh and one 12000 Btuh (ducted) 6 Data from combination of two Indoor Units 6000 Btuh and one 9000 Btuh (non-ducted) or three 9000 Btuh (ducted) 7 Data from combination of four Indoor Units 9000 Btuh (non-ducted and ducted) 8 Indoor units receive power from outdoor units through field-supplied interconnected wiring 9 49 Applies to installations where the outdoor unit is installed below the indoor unit
Power factor equals 97 percent
Specifications are subject to change without notice
MULTI-ZONE ENERGY STAR AND TAX CREDIT SYSTEMS
Model Indoor Unit Combinations SEER HSPF
MXZ-2B20NA-1 2 x MSZ- GE09NA 18 8 9
MXZ- 3B24NA 2 x MSZ- GE06NA 1 x MSZshy GE09NA
17 5 9 3
MXZ- 3B24NA 2 x MSZ-GE06NA 1 x MSZ- GE12NA
17 5 93
For more details on all ENERGY STAR and tax credit systems go to wwwmitsubishicomfortcomtaxcredit
See page 25 for additional info on efficiency
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 21
MXZ-8B48NA THE ULTIMATE ZONING SOLUTION
The Mitsubishi Electric MXZ-S84SNA eight-zone unit As a member of the expanding MXZ-B Series of multi-zone systems the MXZ-8B outdoor unit incorporates branch boxes to connect up to eight indoor units MXZ- 8 B48 NA (2 1 - 8 1 )
Outd oor Uni t The INVERTER-driven compressor at the heart of the MXZ-8B -~-- shy
outdoor unit provides variable capacity control allowing the system to adjust to the specific demands of the interior space ~ as needed not the hard start and stop of a traditional system I[iDA Jinstalled in most US homes
The MXZ -8B48NA has only one port on the outdoor unit for two insulated refrigerant lines which run into the home or business to connect to a branch box or boxes From the branch box(es) gas and liquid refrigerant piping run to each of the indoor units The LEV in the branch box(es) controls the refrigerant flow as the load of each zone changes
Through the branch box(es) (the PAC-AKA31 BC three-port andor the PAC-AKA51 BC five-port) the system can connect from two indoor units up to eight indoor units depending on application requirements
The flexibility of the system doesnt stop there The MXZ-8B48NA has rated capacities of 48000 Btuh for cooling and 54000 Btuh for heating System operation however can range from a minimum 12000 Btuh to a maximum 54000 Btuh in cooling and a maximum of 60000 Btuh in heating This type of performance supports a large variety of applications
The MXZ-8B48NA allows for further flexibility because it supports a connected indoor unit capacity from 22 to 130 or 12000 Btuh to a maximum 70200 Btuh depending on diversity
Connectable Indoor Units General Features bull Four-ton outdoor unit can support up to
eight indoor units using branch boxes bull Wide variety of indoor unit styles
-=--_-=-----= - - J _ 1
including wall-mounted floor-standing MSZ-FE09 12 18NA MSZ-GE06 09 12 15 18 24NA ceiling-cassette ducted
bull Individual control up to eight (8) zones using wired or wireless controls
bull Advanced microprocessor control bull Auto restart following a power outage bull Self-check function offering SEZ-KD09 1215 18NA PEAD-A24AA
integrated diagnostics ~--- Jbull Limited warranty five years on parts and
defects and seven years on compressors
SLZ-KA09 1215NA MFZ-KA09 12 18NA
22 MITSUBISHI ELECTRIC LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
I
RMULTI-ROOM MXZ-8 INVERTER HEAT PUMP
Model Name Outdoor Unit MXZ-BB4BNA Cooling 1 Rated Capacity
Non-ducted Rated Total Input Ducted
Maximum Capacity
Rated CapacityHeating at
Rated Total InputIndoor Unit 4JO F 2 Non-
ductedDucted Maximum Capacity
Rated Capacity Heating at
Rated Total InputlJO F 3 Non-ductedDucted Maximum Capacity
Power Supply Phase Cycle Voltage
Indoor - Outdoor Sl - S2 Voltage
Indoor - Outdoor S2 - S3
MCA
Recommended FuseBreaker Size
Fan Motor
Compressor
Airflow (CoolingHeating)
Refrigerant Control
Outdoor Unit Sound Pressure Level at Cooling 1
Sound Pressure Level at Heating 2
External Finish Color
Dimensions
Weight
Total Capacity 22-130
Indoor Unit ModelQuantity
Remote Controller Type
Type
Refrigerant Charge
Oil
Gas Side OD Refrigerant Pipe
Liquid Side OD
Height Difference (Max)
Maximum Distance between (Outdoor unit and farthest indoor unit)
Refrigerant Pipe Length Maximum Pipe Length -Branch box to Indoor Unit
Total Maximum line length between Branch Box and All Connected Indoor Units
Total Length (Max)
Connection Method IndoorOutdoor
Includes both branch boxes if there are two
Branch Boxes (At least one branch box required)
Btuh
W
Btuh
Btuh
W
Btuh
Btuh
W
Btuh
A
A
Type x Quantity
Motor Output (kW)
Model (Type)
Motor Output (kW)
CFM
dB(A)
dB(A)
W In
D In
H In
Lbs
Btuh
Lbs Oz
Type (fl oz)
In
In
Ft
Ft
Ft
Ft
Ft
4800048000
57806470
54000
5400054000
48205270
60000
3300034700
29503390
3660036550
1 Phase 60Hz 208 230V
AC 208-230V
DC12-24V
32
40
Propeller x 2
0086 + 0086
DC INVERTER-driven Scroll
29
3530
Linear Expansion Valve
54
55
Munsell No 3Y 78 11
37-716
13+1-3 16
53-3 16
278
12000 - 70200
600 - 24000 2-8
Associated with Indoor Unit Model
R410A
18 112
FV50S (73)
58
38
6698 4
230
49
197
377
FlaredFlared
Compatible with the MSZ-A MSZ-FO MSZ-FE MSZ-GE MFZ-KA SEZ-KD PLA and PEAD series indoor units
NOTES Test conditions are based on AHRI 210240 One indoor unit is turned off during low-speed testing under the new test conditions Systems actually exhibit higher energy efficiencies during normal operation
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F (35deg C) WB 75deg F (24deg C)
2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 4]0 F (8deg C) WB 43deg F (6deg C)
3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 17deg F (-8deg C) WB 15deg F(-9deg C)
4 66 applies to installations when the outdoor unit is installed below the indoor unit
Power factor equals 97 percent
Specifications are subject to change without notice
Note Maximum installed capacity is the maximum total of all connected indoor units NOT the maximum capacity produced
Only a single Lineset is needed from the outdoor unit to branch box
See page 25 for MXZ-B information on efficiency
Required Branch Boxes for MXZ-SB4BNA (Maximum of 2 branch boxes can be connected to one outdoor unit requires joint MSDD-50AR-E or MSDD-50BR-E)
s c d N o J ro Vl
0 ro n 3i n OJ d o J U)
PAC-AKA51 BC Branch Box
PAC-AKA31 BC Branch Box LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 23
MSZ WALL-MOUNTED INDOOR UNITS (FOR MXZ-8 OUTDOOR UNITS)
R
(MSZ-GE12NA MODEL SHOWN)
-000 IIIIIII 9000 9000 12000 12000 14000 17200
Heating at 4r Rated Capacity Btuh 7200 10900 10900 14400 13600 18000 21600
F2 Power Supply I Phase Cycle Voltage J -phase 60Hz 208 230V 3
Iindoor Outdoor S1 S2 AC 208 230V
Iindoor Outdoor S2 S3 DC12-24V Voltage
Iindoor Remote vomr Iller Wireless Type (Optional Wired vomroller DC 12V)
IMCA A 10 IFan Motor FLA 076
DRY 162-226shy145-170shy
162-226shy205-272shy 230-275shy
Airflow at Cooling (CFM)
145-170-237-321-399 339-381
237 -321shy381-410
335-420shy 339-420shy(Quiet-Lo-Med-Hishy 399 533 533 Super Hi or Lo-Med-
WET 144-202shy109-134shy
144-202shy170-237shy 194-240shy
Fan Hi-Powerful)1 (CFM)
109-134-201-286-364 307-343
201-286shy350-367
300-385shy 304-385shy364 498 498
Airflow at Heating 145-170shy 145-170shy 145-170shy 205-247shy 230-275shy
(Quiet-Lo-Med-Hi- WET 233-321shy 237-321shy
166-240shy237-321shy
166-240shy304-367shy 339-431shy
Super Hi or Lo-Medshy (CFM) 406 406
367 -381 406
399-420 463 512
Hi-Powerful) 2 Sound Pressure Level at Cooling
19-22-30shy 26-32-38shy 28-33-38shy(Quiet-Lo-Med-Hi-Super Hi or Loshy dB(A) 19-22-30-37 -43 22-31-39-42
37-45 22-33-43-45
44-49 44-49Med-Hi-Powerful) 1
Sound Pressure Level at Heating 19-22-30shy 26-30-35shy 28-33-38shy
(Quiet-Lo-Med-Hi-Super Hi or Loshy dB(A) 19-22-30-37 -43 22-31-40-42 37-43
22-23-43-44 40-46 43-48
Med-Hi-Powerful) 2
I External Finish Color Munsell No 10Y 92 02
IWln 31 middot716
Dimension Unit 10 In 9 18 10-18 9middot18 10-18 9-18
IH In 11-58
I Weight Unit ILbs 22 27 22 27 22 I Field Drainpipe ~D lin 58 Remote Con-
Type Wireless Remote (Optional Wired Controller) troller
ITvpe B41QA Refrigerant ~s$ideOD lin 38 Pipe I Liquid Side 00 In 14
Connection IndoorOutdoor FlaredFlared
Method
1~
II 18000 22500
21600 27600
388-469shy 38$-469shy628-738 628-738
347-420shy 347-420shy562-661 562-661
388-469shy 388-469shy628-738 628-738
34-41-49-53 34-41-49-53
32-41-49-52 32-41-49-52
43-516
9-38
12-1316 37
58 38
MXZ-2B20NA is also compatible with the MSZ-A and MSZ-FD series indoor units NOTES Test conditions are based on AHRI 210240
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F(6deg C) 3 Indoor units receive power from outdoor units through field-supplied wiring
Specifications are subject to change without notice LIMITED WARRANTY Seven-year warranty on compressor Five-year warranty on parts For data on specific indoor unit combinations see page 21
SEZ DUCTED INDOOR UNIT (FOR MXZ-8 OUTDOOR UNITS)
I
Notes 1 Cooling-Indoor DS 80deg F(267deg C) WS 67deg F(194deg C) Outdoor DS 95deg F (35deg C) WS 75deg F(239deg C)
2 Heating-Indoor DS 70deg F(211 deg C) WS 60deg F(156deg C) Outdoor DS 47deg F (83deg C) WS 43deg F(61 deg C)
3 External static pressure is factory set to 006 WGAdjustable via the
1---------t---+-----L-------------1~---__I PAR-21MAA
1--_____----__________+-____---L____----~_____________1 4 Indoor units receive power
jE~~~~-------------r----1-----~-~~~~~~~~-----___1 from outdoor units through fieldsupplied interconnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven-year warranty on compressor Five-year
1---------------------+---+------------------------1 warranty on parts
~--__I_~----------+-------~l----------I For data on specific indoor unit combinations see page 21 - 23
I--~------+~-----------~----------r_------------I
- Reference page 17 for SEZ static performance curves
24 MITSUBISHI ELECTRIC
25-30-35-40 26-31-36-41 35-38-42-46
25-30-35-40 28-31-36-41 35-38-42-47
MFZ FLOORLOW WALL INDOOR UNIT (FOR middotMXZ-8 OUTDOOR UNITS)
------shy
-==
Airflow at Heating (CFM) 177-198-219-332 184-201-219-335 261-275-297-434
Voltage
Fan
Airflow at Cooling (Lo-Med-Hi-Super Hi)1
169-205-251-314 251-279-325-394
163-197-241-303 170-207-252-309 241-269-313-379
(Lo-Med-Hi-Super Hi) 2
SLZ CEILING-RECESSED INDOOR UNIT (FOR MXZ-8 OUTDOOR UNITS) EFFICIENCY RATINGS
Voltage
Fan
Galvanized-steel SheetsMunsell 64Y 89 04
Refrigerant Pipe
Model Indoor Unit Type SEER HSPF
MXZ-2B20NA-1
Non-dueted 18 89
Dueted and Non-dueted 1675 87
Dueted 155 85
MXZ-2B20NA-1 ENERGY STAR amp
TAX CREDIT 2 x MSZ-GE09NA 18 89
MXZ-3B24NA
lJon-dueted 175 93
Dueted and Non-dueted 1625 89
Dueted 150 85
MXZ-3B24NA ENERGY STAR amp
TAX CREDIT
2 x MSZ-GE06NA 1 x MSZ-GE09NA
175 93
MXZ-3B24NA ENERGY STAR amp
TAX CREDIT
2 x MSZ-GE06NA 1 x MSZ-GE12NA
175 93
MXZ-3B30NA
Non-dueted 175 105
Dueted and Non-dueted 16 100
Dueted 145 95
MXZ-4B36NA
Non-dueted 18 93
Dueted and Non-dueted 16 5 92
Dueted 150 9 0
MXZ-BB4BNA
Non-dueted 15 87
Dueted and Non-dueted 14B B8
Dueted 147 89
Connection IndoorOutdoor FlaredFlared
Method
Notes 1 Cooling-Indoor DB 80deg F(267deg C) WB 67deg F(194deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(239deg C) 2 Heating-Indoor DB 70deg F(21 1 deg C) WB 60deg F(156deg C) Outdoor DB 47deg F(83deg C) WB 43deg F(61 deg C) 3 Indoor units receive power from outdoor units through field supplied interconnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 25
Notes 1 Cooling-Indoor DB 80deg F(267deg C) WB 67deg F (194deg C) Outdoor DB 95deg F (35deg C)WB 75deg F (239deg C)
2 Heating-Indoor DB 70deg F(211deg C) WB 60deg F (156deg C) Outdoor DB 47 F (83deg C) WB 43deg F (61 deg C)
3 Indoor units receive power from outdoor units through field supplied interco(lnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven -year warranty on compressor Five-year warranty on parts
Presently there is no 1 1 system with the MFZ indoor unit
s c
N o J ro Vl
C ro n ~ n OJ t o J V)
M-SERIES RATING CONDITIONS
INDOOR INTAKE AIR TEMPERATURE
OUTDOOR INTAKE AIR TEMPERATURE
COOLING
MAXIMUM
95degF DB 71 degF WB (MU SUZ MXZ-2B20-13B243B304B36) 90degF DB 73degF WB (MUZY-GE MUZ-FE MUzy-D)
115degF DB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B24 3B304B368B48)
MINIMUM 67degF DB 57degF WB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B201 3B243B304B36)
14degF DB (MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B24 3B304B36) 23degF DB (MXZ-8B48) 6rF DB (MU)
MAXIMUM 80degF DB 6rF WB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B243B304B36)
75degF DB 65degF WB (MUZY-GE MUZY-GA24 MUZ-FE SUZ MXZ-2B20-1 3B243B304B36) 70degF DB (MXZ-8B48)
HEATING
MINIMUM 70degF DB 60degFWB (MUZ-GE MUZ-GA24 MUZ-D MUZ-FE SUZ MXZ-2B20-1 3B243B304B36)
-13degF DB -15degFWB (MUZ-FE) -4degF DB -5degF WB (SUZ MUZ-GE) 5degF DB 4degF WB (MUZ-GA24 MXZ-8B48NA) 6degF DB 5degF WB (MXZ-2B20-1 3B24 3B304B36) 14degF DB 13degFWB (MUZ-D)
MU units operate at intake air temperature down to 10deg Fwith the addition of an ICM-326HM-1 low temperature control
REFRIGERANT TUBING SETS
OPTIONAL ACCESSORIES
REFRIGERANT LINE LENGTH FLARE FLARE _INDOOR UNIT OUTDOOR UNIT
MS-A09WA MU-A09WA 35 MS-A12WA
65 MU-A12WA 35
MSY-GE09NA 65
MUY-GE09NA 40
MSY-GE12NA
65
MUY-GE12NA 65 40
MSY-GE15NA MUY-GE15NA 40
MSY-GE18NA
65
MUY-GE18NA 100 50
MSZ-GE09NA MUZ-GE09NA 65 40
MSZ-GE12NA MUZ-GE12NA 40
MSZ-GE15NA
65
MUZ-GE15NA 40
MSZ-GE18NA
65
MUZ-GE18NA 100 50
MSY-GE24NA MUY-GE24NA 100 50
MSZ-GE24NA MUZ-GE24NA 100 50
MSY-D30NA MUY-D30NA 100 50
MSZ-D30NA MUZ-D30NA 50
MSY-D36NA
100
MUY-D36NA 50
MSZ-D36NA
100
MUZ-D36NA 100 50
MSZ-FE09NA MUZ-FE09NA 40
MSZ-FE12NA
65
MUZ-FE12NA 40
MSZ-GE06091215NA MSZ-FE0912NA
65
MXZ-2B20NA-1 164 4933MFZ-KA0912NA SEZ-KD09 1215NA
MSZ-GE0609 121518NA MSZ-FE091218N MFZ-KA09 1218NA MXZ-3B24NA 164 4933 SEZ -KD09 12 15 18NA SLZ-KA09 12 15NA
MSZ-GE0609 121518NA MSZ-GA24NA MSZ-FE091218NA
MXZ-3B30NA 4933230MFZ-KA091218NA SEZ -KD09 121518NA SLZ-KA09 12 15NA
MSZ-GE0609121518NA MSZ-GE24NA MSZ-FE09 12 18NA
MXZ-4B36NA 230 4933MFZ-KA091218NA SEZ -KD09121518NA SLZ-KA09 12 15NA
MSZ-GE0609 12 15 18NA MSZ-GE24NA MSZ-FE09 12 18NA
MXZ-8B48NA 6698377MFZ-KA091218NA SEZ-KD09121518NA SLZ-KA09 12 15NA
PART NUMBER I USE WITH I DESCRIPTION
Port Adapters and Connection Pipes MAC-A454JP-E MXZ-Series Adapter 38 X12
MAC-A455JP-E MXZ-Series Adapter 12 X38
MAC-A456JP-E MXZ-Series Adapter 12 X58
MSDD-50AR-E MXZ-Series Branch Box Tee Distribution Pipe - Flare Connection between two branch boxes
MSDD-50BR-E MXZ-Series Branch Box Tee Distribution Pipe - Braze Connection between two branch boxes
PAC-493PI MXZ-Series Adapter 14 X38
PAC-SG76RJ-E MXZ-Series Adapter 38 X58
OPTIONAL ACCESSORIES CONTINUED ON NEXT PAGE
49 amp 66 applies to installations in which the outdoor unit is installed below indoor unit26 MITSUBISHI ELECTRIC
OPTIONAL ACCESSORIES (CONTINUED)
PART NUMBER USE WITH DESCRIPTION Control Options and Accessories
M21 JKO 307 M-Series Indoor Units Remote temperature sensor for M-Series indoor units
MAC-397IF-E
MAC-399IF-E
PAC-YU25HT
PAR-21 MM-G
M-Series INVERTER Units
M-Series INVERTER Units
SEZ-KD Indoor Units
Use with P-Series SEZ and for wired M-Series Controller
MA and contact terminal interface - Required to use PAR-21 MM wired wall mount controller with M-Series Systems
CMCN M-NET control adapter I Interface for Mr Slim M-Series MSYZ SEZ I MFZ
External Fan I Heater control relay adapter
Deluxe MA remote controller (Requires MAC-397IF-E for use with M-Series - MSYZ MFZ)
SEZ Wireless remote controller for SEZ units (Requires signal receiver PAR-SA9FA-E)PAR-FL32MA
PAR-SA9CA-E SEZ Wireless signal receiver for SEZ
3-pole disconnect switch 30A 600V turns off power between indoor and outdoor units shyM-SeriesTAZ-MS303
mounts in 2 X 4 utility box and requires standard single gang switch platecover - Low Ambient
ICM-326HM-2 M-Series Non-INVERTER units Low ambient head pressure controller MUZ-GE091215 IVIUZ-FE0912 SUZ-KD091215
Drain pan heaterMAC-640BH-U outdoor unit
MAC-641 BH-U MUZ-GE18 SUZ-KD18 outdoor unit Drain pan heater Filters
MAC-1415FT-E Anti-allergy enzyme filter
MAC-2300FT
MSZlMSY-D3036
Anti -allergy enzyme filter
MAC-308FT
MSYMSZ-GA24
MSZ-FD912 I FE0912 Platinum deodorizing filter
MAC-408FT-E Anti-allergy enzyme filter
MAC-415FT-E
M-Series Indoor Unit - GE09GE12GE15GE18
MFZ-KA Air Cleaning FilterAnti-Aliergy Enzyme Filter
MAC-418FT Anti-allergy enzyme filter
Filter Boxes
FBL1-1
MSZ- FD912 I FE091 2
FB Series Filter Box for SEZ-KD09NA Optional filter box with MERV 8 filters
FB Series Filter Box for SEZ-KD1215NAFBL1-2 Optional filter box with MERV 8 filters
and PEA-A 12M
FBL1-3 FB Series Filter Box for SEZ-KD18NA Optional filter box with MERV 8 filters
Pumps
SI1730-230 MSYZ - 30000 Btuh or greater Sauermann mini condensation pump 230V
S13100-115 MS-Series - non-INVERTER Sauermann mini condensation pump 115V
S13100-230 Sauermann mini condensation pump 230VMSYZ - Less than 30000 Btuh
Miscellaneous BRP-1 Bottom Return Plate for SEZ-KD09NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-2 Bottom Return Plate for SEZ-KD12KD15-NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-3 Bottom Return Plate for SEZ-KD18NA Converts low profile ducted indoor unit from rear return to bottom return
BV12FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderreglnsulated - 12
BV14FSI Use with any Mr Sl im multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 14
BV38FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 38
BV58FSI Use with any IVIr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 58
Condensing unit wall mounting brackets (set of 2) - 440 lb capacity painted steel NOTE CWMB1 IVIU and PU outdoor units Installer is responsible to select and provide suitable hardware and materials to insure proper
mount of bracket to wall
DSD-400N M-Series DiamondBacktrade Platform Stands MUZ-GE18 I MUZ(y)-03036 I
MAC-811DS Drain socket assemblySUZ-KA18
MAC-851DS MUZ-FD0912 Drain socket
MAC-855SG M-Series Air outlet guide
MAC-856SG M-Series Air outlet guide - MXZ-3B24 I 3B30 I 4B36 NA
MAC-860DS MUZ-GE091215 I MUZ-FE0912 Drain socket
MAC-889SG M-Series Air outlet guide- MXZ-2B20NA
MAC-S99SG M-Series Air outlet guide
PAC-SG59SG-E IVIXZ-SB4SNA Air outlet guide (1 piece) I MXZ-SB48NA (Requires 2 pieces)
PAC-SG61 DS-E MXZ-8B4SNA Drain socket - connector
PAC-SG64DP-E MXZ-SB48NA Drain pan
RCMKP1CB lVI-Series Wireless Lockdown bracket for remote controller
lILTRILlTE1 All M-Series Condensing unit mounting pad 16 x 36 x 3
MITSUBISHI ELECTRIC 27
MXZ-8 Series Port Adapter chart Port Adapter Unit Port
Combinations Required Size
MXZ-2B20NA-1
2-zone combinations wi NA
A 38 x both units s12K 14
1-MAC-A454JP-E B 38 x
6+15 14
9+15 1-MAC-A454JP-E
MXZ-3B24NA
All rated 2-zone combina-NA
A 12 x tions 14
All rated 3-zone combina-NA
B 38 x tions 14
C 38 x 14
MXZ-3B30NA
2-zone combinations wi at NA
A 12 x least one unit s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
9 + 24 14
3-zone combinations wi 1-MAC-A455JP-E
all units s12K
All other rated 3-zone NA
comb
MXZ-4B36NA
2-zone combinations wi at NA
A 12 x least one un it s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
6 + 24 14
1-MAC-A456JP-E D 38 x
9 + 24 14
3-zone combinations wi at NA
least two units s12K
3-zone combinations wi 1-MAC-A454JP-E
two units15K
6+6+24 or 6+9+24 1-MAC-A456JP-E
9+9+24 1-MAC-A456JP-E
4-zone combinations wi at 1-MAC-A455JP-E
least three units s12K
6+6+15+15 1-MAC-A454JP-E
6+6+15+15 1-MAC-A454JP-E
Note When using the Pu-A24BA PCA-A24KA or PEAD-A24AA two port adapter will be needed 1-MAC-A456JP-E (12 x 58) A port or 1-PACshySG76RJ-E (38 x 58) B C and D ports and 1-PAC493PI (14 x 38)
28 JMITSUBISHI ELECTRIC
6+6+246+9+24 6+12+249+9+24 9+12+24 or 12+12+24
6+15+24 6+18+24 9+15+249+18+24 12+15+24 or 12+18+24
15+15+24 15+18+24 or 18+18+24
15+24+24 or 18+24+24
Combinations of 4 or more zones
1-PAC-SG76RJ-E
See notes for application below
2
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
See notes for application below
PORT A =38 gas x 14 liquid
PORT B =38 gas x 14 liquid
PORT C =38 gas x 14 liquid
PORT A =38 gas x 14 liquid
PORT B = 38 gas x 14 liquid
PORT C = 38 gas x 14 liquid
PORT D =38 gas x 14 liquid
PORT E =12 gas x 14 liquid
Notes for application bull Check the lineset sizes for your indoor selected models bull Select the branch box or boxes needed for your application bull Compare indoor unit lineset sizes as compared to branch
box sizes bull Connect 15K + indoor units to the larger port on the
(PAC-AKA51 BC) bull Adapt lineset size with appropriate port adapter from
above list bull When using the PU-A24BA or PEAD-A24AA two port
adapter will be needed 1-MAC-A456JP-E (12 x 58) or 1-PAC-SG76RJ-E (38 x 58) and 1-PAC493PI (14 x 38)
-fv
~ DIAMONDBACKtrade
~) BV-Series Ball Valves Model numbers
BV14FFSI BV38FFSI
LISTED 891N REFRIGERANT
BV12FFSI VALVE bull Engineered for Mini-split andBV58FFSI
Multi-split HVAC Units bull Size available 14 38 12 58
bull Full Port Designbull Fully factory assembled bull Furnace brazed and pressure tested bull 700 PSIG Rated bull Each ball valve is equipped with Schraderreg Valve
for refrigerant service bull R-410A Compatible bull Design working pressure 700 PSIG bull Temperature range bull Flare Connections
-40 0 F to +3250 F (-400 C to + 1490
C) bull Forged brass body and seal cap bull Teflonreg seals and gaskets (no synthetic a-rings) bull Seal cap design permits valve operation without
removal of seal cap bull Suitable for use with R-11 R-22 R-123 R-125
R-134A R-236FA R-4202A R-402B R-404A R-407C R-410A R-500 R-502 and R-507
bull One year limited materials and workmanship
Part Number SAE Flare
A B C 0 E F
BV14FFSI 14 619 260 180 122 142 110
BV38FFSI 38 630 267 180 122 142 110
BV12FFSI 12 651 267 180 122 142 110
BV58FFSI 58 664 267 180 128 142 110
Ball valves come With an insulation piece warranty on Ball Valves
~ DIAMONDBACKtrade
~) Platform Stands
Lift the Mitsubishi Electric Comfort Solution
outdoor unit to new heights with our Diamondback Platform Stands
bull Easy to install
bull Available for all sizes of Mr Slim outdoor units
bull Color matched to the outdoor units
Model Number DSD-400N
L 15-34 x W 3-14 x H 3-14
r
)MITSUBISHI ELECTRIC 29
~ DIAMONDBACKtrade LINESETS
~~
Twin-Tube Lineset Insulation Design
bull Balanced outside diameter for uniform coiluncoil position stability
bull Minimum 12 insulation thickness on both tubes Diamondback Advantages include the following features
bull Quick efficient and economical field installation using factory applied Twin Tube insulation and flare connections with flare nuts mounted
bull Correct lengths for reducing waste and time
bull Quality consistency and economy
bull All Diamondback Lineset tubing is tested in accordance with ASTM E243
Filter Boxes
FB Series filter boxes are available in compatible sizes for all Mr Slim horizontal ducted indoor units
FBL 1 filter boxes include 1 thick pleated MERV 8 filter(s) installed Filters are tested in accordance with ANSIASHRAE Standard 522 and Rated Class 2 under UL Standard 900
The cabinet is constructed of non-insulated 20 gauge G-60 galvanized
FBL1-1 FB Series Filter Box for SEZ-KD09NA
FBL1-2 FB Series Filter Box for SEZ-KD12KD15-NA
FBL1-3 FB Series Filter Box for SEZ-KD18NA
steel with foam gasket and provides an air-tight connection to indoor unit and access door Gasket material complies with UL 723 requirements
A screw-through cabinet design for secure attachment to indoor unit and return connection in rear is easily field-converted to bottom return
30 MITSUBISHI ELECTRIC
bull
bull
bull
bull
bull
bull
LINE-HIDE~ Put a professional finish on air-conditioning
installations with an easy-to-install modular
system that beautifies exteriors and
protects Linesets drainlines and wiring
Can be use it indoors too Meets UL94v-O for interior applications
Has snap-on covers and a full selection of couplings elbows T-joints caps and more for any application complex or simple
Offers high-quality PVC with UV inhibitors for outdoor service in all weather conditions
Can be painted with most house paints to match exterior decors
Is not just for HVAC Hide any exterior cabling piping or wiring
Available in four sizes 2-14 3 4 and 6 tubes
Download a brochure at wwwline-hidecom to find out more information
For more information on our CITY MULTI VRF product line visit our website at wwwmitsubishiprocom
_lIJrUlllln ~ ~IIII1 fInll l
~
l bull bull
JMITSUBISHI ELECTRIC 31
----
Hybrid Catechin pre-filters -- shy
- shy
Total Comfort
Additional Air Circulation With the WIDE VANE or SWING mode available on the MSY(Z)-GE24 D3036NA there is an option for ~~~~lQcnborizontal airflow directions that provide 150
0
of lateral airflow for greater conditioned air circulation
-- -----_ ~~ iii
~~---- 150
0
Multiple Filters for Cleaner Healthier Ai r Mitsubishi Electric indoor units use a sophisticated multi-part filter system to remove contaminants such as allergens viruses and bacteria from the air
A hybrid catechin pre-filter absorbs odorshycausing gases The hybrid-coating process makes the catechin filter washable and - if properly maintained with regular cleaningshyremains effective for up to 10 years
A Blue-enzyme anti-allergen filter reduces germs bacteria and viruses and helps trap dust pollens mites and other particles The filter uses an enzyme catalyst to help break down the sulfur atom bonds in allergen proteins transforming them into non-allergen proteins and effectively cleaning the air The filter should be cleaned regularly to maintain efficiency
STANDARD FILTER SYSTEM (USED IN MSYMSZmiddotGElFE18GND MODELS)
Front Panel - shy
Blue Enzyme anti-allergen filter
ENHANCED FILTER SYSTEM (USED IN MSZmiddotFE0912NA MODELS)
Programmable Comfort Smart Set featured on MSZ-GE systems provides the option to program multiple settings into one quick-press feature providing an additional level of comfort control
The POWERFUL mode (found on select systems) is available to cool or heat any desired space quickly by lowering the set temperature in cooling mode or raising the set temperature in heating mode both by T F In POWERFUL Mode the fan speed increases for 15 minshyutes then the system resumes all standard operations
Vl l
OQ
([) I
N o l ([)
Vl lt(n r-+ ([)
3 o lt ([)
s ([)
~ OJ l a --I ([) nr l o o ~
The high-efficiency MSZ-FE0912NA indoor units incorporate the standard Catechin filter plus two more filters for triple filtration The second filter a Blueshyenzyme filter made of a fibrous material renders allergens harmless by using enzymes The third filter a Platinum Catalyst Deodorizing filter has a ceramic surface absorption element and uses nanotechnology for high-power odor absorption Periodic cleaning following the recommended procedures will maintain filter effectiveness for up to two years This combination of filters provides a complete air-purifying system within the ultimate comfort solution
Front Panel - shy
Hybrid Catechin pre-filters
cJ shy Blue Enzyme anti-allergen filter
I
MITSUBISHI ELECTRIC 7
---- -- -- -
System Lineup RESIDENTIAL AND LIGHT COMMERCIAL SYSTEM MODELS AND CONTROLLERS
SINGLE
MSMU Air Conditioners
9500 to 12000 Btuh 13 SEER
bull Provides cooling-only system bull Non-INVERTER rotary compressor bull Ideal for spaces such as
bedrooms garages out-buildings video monitoring
- ROOM WALL-MOUNTED Ale (cooling only)
MSYMUY Air Conditioners
3800 to 34600 Btuh Capacity Range 151 - 21 SEER
~ -
bull Cooling-only system bull INVERTER-driven compressor bull WIDE VANE for a wider angle of airflow 150
0
from left to right (on GE24D30D36 models)
bull Ideal for spaces such as bedrooms garages large open rooms and bonus rooms
SINGLE-ROOM WALL-MOUNTED HEAT PUMPS (coo lin g and heatin g)
MSZMUZ Heat Pumps
3800 to 33200 Btuh Capacity Range
145 - 21 SEER 82 - 10 HSPF
bull Uses INVERTER-driven compressor bull Provides cooling and heating in a wide range
of capacities bull Offers a WIDE VANE for a wider angle of airflow 1500 from
left to right (on GE24D30D36 models) bull Ideal for applications in bedrooms home offices living
rooms dining rooms bonus rooms basements kitchens guard houses and more
Up to 26 SEER
MSZMUZ-FE0912NA High - Efficiency Heat Pumps
2800 to 25200 BtuH capacity range 202 - 26 SEER
10 - 106 HSPF
bull INVERTER-driven compressor bull Quiet operation as low as 19dB(A) bull i-seetrade Sensor technology bull Enhanced filtration system bull H2ireg high~heat capabilities (see page 12 amp13)
MSZ-FE09 is 100 percent at 50 F MSZ -FE12 is 92 percent at 50 F MSZ-FE18 is 100 percent at 50 F
SI NGLE-ROOM LOW WALL or FLOOR-STANDING UNIT (fo r use with MXZ -8)
New to our lineup is a Low Wall or Floor-Standing model that can fit into those once difficult installations
MFZ These units provide comfort in spaces such as (For use with MXZ-8 finished attics with knee walls basements with Outdoor Units only) low ceilings and glass-walled sunrooms
bull Provides cooling and heating in Mounted three inches above floor level these models a wide range of capacities provide conditioned air two vents and provide direct
bull Two outlet air vents front-panel access to the filter for easy cleaning The - Upper vent for cooling or heating MFZ can even be recessed in a wall during installation - Bottom vent for heating only provided proper clearances are maintained (Currently there is
bull Flush or recessed installation no 1 1 system with M FZ)
8 MITSUBISHI ELECTRIC
SING LE -ROOM HORIZONTAL- DUCTED HEAT PUMPS (coo lin g and heat ing)
WIR ELESS and W IR ED REMOTE C O NTRO LLERS
PAR-21 MAA Wireless remote controller Set Temperature
for wall-mounted and floor-standing indoor units ----- OnOff
Timer Menu Fan Speed
Fan Speed Filter
Test Run Set Time
CheckEcono Cool
Airflow UpDown Timer OnOff
Louver
Ventilation
Reset ---- shy Optional wired controller for the SEZ SLZ and MFZ indoor units (Optional controller for wall-mounted is
available and floor-standing indoor units Unit requires MAC-397 If adapter)
MHK1 WIRELESS REMOTE CONTROLLER Exclusive for INVERTER-driven Mr Slimreg Systems
Wireless Technology a SEZ and SLZ 11 systems with SUZ outdoor unit only
MIFH1
MITSUBISHI ELECTRIC 9
AMITSUBISHI ELECTRIC
l~ 1000
~r t ~~~O
MRCH1
rtj n-shy --1r-a-1-shy
Mode ------ -- shy
SEZSUZ If your customer is looking for discrete zoned comfort then a short-run ducted unit Heat Pumps is the right solution As a stand-alone system or connected to a MXZ multi-room
3800 to 19000 BtuH system the SEZ ducted units provide energy efficiency quiet operation and a Capacity Range compact design for quick easy instqllation hidden either in the ceiling or beneath
15 SEER _---~~mm the floor 175 - 10 HSPF
J ~ All of the 11 systems are ENERGY STAR certified and two systems qualify for
~ the federal tax credit These systems provide customers with an environmentally friendly indoor unit with a similar installation and familiar style
These SEZ indoor units also connect to MXZ multi-zone systems providing a wide array of installation options to best fit any application
SING LE -R OO M C EI LING -REC ESSED CASSETTE UN IT
SLZSUZ Heat Pumps The SLZ -KA ceiling-recessed units casette offer a wide
3100 to 22200 BtuH air-flow pattern for better air distribution in a less obtrusive Capacity Range style These indoor units can be used in 11 heat pump
15 - 16 SEER and multi-zone systems providing more options to your customers Install SLZs in a hard ceiling (with a access panel for
bull 96 HSPF
servicing) or in a 2x2 extra space drop ceiling With a built-in drainshylift mechanism for condensate removal and a 4 ventilation-air intake knockout option and multiple options for the 11 systems the SLZ
~ ~ handles a variety of installation needs
Two of the three 11 systems are ENERGY STAR qualified
Vl l
OQ
(I) I
N o l (I)
Vl ltV (I)
3 Vl r o ~ n OJ V (I)
1shy(MS-A12WA MODEL SHOWN)
MS COOLING-ONLY
IJON-INVERTER
Model Name Indoor Unit
Outdoor Unit
MS-A09WA MS-A12WA
MU-A09WA MU-A12WA
Cooling 1
Rated Capacity Btuh 9500 12000
Capacity Range Btuh
Total Input W 870 1070
Energy Efficiency SEER 13
Moisture Removal Pintsh 27 32 Sensible Heat Factor 068 070
Power Supply Phase Cycle Voltage 1 Phase 60Hz 115V 2
Voltage Indoor - Outdoor L1-N AC 115V Indoor - Outdoor N-2 AC 115V Indoor - Remote Controller Wireless Type
Indoor Unit
MCA A 12
Fan Motor FLA 095
Airilow (Lo-Med-Hi Poweriul)
DRY (CFM) 183-261-335-367 222-286-406-446
WET (CFM) 162-233-300-328 198-254-363-399
Sound Pressure Level (Lo-Med-Hi)
dB(A) 26-32-40-42 33-38-45
External Finish Color Munsell No 1OY 9202
Dimension Unit
W In 30-1116
0 In 8-14
H In 11-34
Weight Unit Lbs 23
Field Drainpipe Size 00 In 58
Outdoor Unit
MCA A 14 16
MOCP (Time Delay) A 15 20
Fan Motor FLA 063 093
Compressor
Model (Type) Single Rotary
RLA 93 1082
LRA 47 56
Airilow CFM 1083 1327
Refrigerant Control Capillary Tube
Sound Pressure Level (Cooling) 1
dB(A) 47 52
External Finish Color Munsell No 3Y 7811
Dimensions
W In 31-12 33-716
0 In 11-14 11-716
H In 21-58 23-1316
Weight Lbs 78 96
Remote Controller Type Wireless Remote
Refrigerant
Type R410A Charge Lbs Oz 25 31
Oil Type (FI Oz) NE022 (108)
Refrigerant Pipe
Gas Side 00 In 38 12
Liquid Side 00 14
Height Difference (Max) Ft 35
Length (Max) 65
Connection Method IndoorOutdoor FlaredFlared
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling) - Indoor DB 800 F(270 e) WB 670 F(190 e) Outdoor DB 950 F(350 e) WB 750 F(240 e) 2 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice
LlIVIITED WARRANTY ISeven-year warranty on compressor Five-year warranty on parts
10 MITSUBISHI ELECTRIC
I
R ---I Vl
J(MSY-GE1 7NA MODEL SHOWN) OQ
MSY COOLI NG-ON LY (CO NT ) CD N o J CD
s Vl OJ J
Cooling 1 0shy
s Vl -lt Vl
~~~~~-=~------~~--------------------------~~~~----------------------------~ jVoltage
205-272-335shy145-170-237 -321-399
420-533 170-237 -300shy
385-498
26-32-38-44-49Indoor Unit
Outdoor Unit
194-240-304shy385-498
28-33-38-44-49
388-469-628-738
347-420-562-661
34-41-49-53
CD n 3-i n OJ 0389-639-848 o J350-576-763 V)
32-42-49
2 9 43Refrigerant
FV50S (040) NE022 (295)
Refrigerant Pipe
Refrigerant Pipe Length
Connection IndoorOutdoor FlaredFlared
Method
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling) - Indoor DB 80deg F(27deg e) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice
LIMITED WARRANTY ISeven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 11
~ (MSZ-FE12NA MODEL SHOWN)
MSZ HEAT PUMP TAX
CREDIT
Model Name
Cooling 1
Indoor Unit Outdoor Unit
Rated Capacity Btuh
MSZ-GE09NA MUZ-GE09NA
9000
MSZ-FE09NA HshyMUZ-FE09NA bull
9000
MSZ-GE12NA MUZ-GE12NA
12000
MSZ-FE12NA MUZ-FE12NA
12000
H-bull MSZ-G MUZ-G
14000
Capacity Range Btuh 3800-12200 2800-9000 3800-13600 2800-12000 3100-18200
Total Input W 660 (205-1200) 580 (160-650) 960 (205-1300) 930 (160-960) 1080 (160-2000)
Energy Efficiency SEER 21 26 205 23 21
Moisture Removal Pintsh 15 21 25 29 27
Sensible Heat Factor 082 076 074 073 080
Heating at 47deg F 2
Rated Capacity Btuh 10900 10900 14400 13600 18000
Capacity Range Btuh 4500-14100 3000-18000 5500-18100 3000-21000 4800-20900
Total Input W 760 (255-1200) 710 (150-2250) 1170 (340-1660) 950 (150-2250) 1600 (270-2010) HSPF (IV) BtuhlW 10 106 10
Heating at 17deg F3 Rated Capacity Btuh 6600 6700 8800 8300 11300 Rated Total Input W 700 650 900 800 1150 Maximum Capacity Btuh 8700 12500 11200 13600 15900
Heating at 5deg F Maximum Capacity Btuh 7061 10900 9194 12500 13022
Power Supply Phase Cycle Voltage 1-phase 60Hz 208 230V 4
Voltage
Indoor - Outdoor S1 - S2 AC 208 230V
Indoor - Outdoor S2 - S3 DC12-24V
Indoor - Remote Controller Wireless Type (Optional Wired Controller DC 12V)
Indoor Unit
MCA A 10
Fan Motor FLA 076
Airflow at Cooling (Lo-Med-Hi-Super HI-Powerful) 1
DRY (CFM) 145-170-237-321-399 162-226-339-381 145-170-237-321-399 162-226-381-410 205-272-335-420-533
WET (CFM) 109-134-201-286-364 144-202-307-343 109-134-201-286-364 144-202-350-367 170-237-300-385-498
Airflow at Heating (Lo-Med-Hi-Super HI-Powerful) 2
WET (CFM) 145-170-237-321-406 166-240-367-381 145-170-237-321-406 166-240-399-420 205-247 -304-367-463
Sound Pressure Level at Cooling (Lo-Med-Hi-Super HI-Powerful) 1
dB(A) 19-22-30-37-43 22-31-39-42 19-22-30-37-45 22-33-43-45 26-32-38-44-49
Sound Pressure Level at Heating (Lo-Med-Hi-Super HI-Powerful) 2
dB(A) 19-22-30-37-43 22-31-40-42 19-22-30-37-43 22-33-43-44 26-30-35-40-46
External Finish Color Munsell No 10Y 92 I 02
Dimension Unit
Wln 31-716 31-38 31-716 31-38 31-716
0 In 9-118 10-18 9-18 10-18 9-18
H In 11-58
Weight Unit Lbs 22 27 22 27 22
Field Drainpipe Size 00 In 58
Outdoor Unit
MCA A 12
MOCP A 15
Fan Motor FLA 050 056 050 056 050
Compressor
lVIodel (Type) DC INVERTER-driven DC INVERTER-driven Twin
Rotary DC INVERTER-driven DC IIWERTER-driven Twin Rotary
RLA 66 86 66 86 74
LRA 82 108 82 108 93
Airflow (CoolingHeating) CFM 11511225 1102 11187 12291172 1102 11187 12431229 Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(A) 46 48 49 48 49
Sound Pressure Level at Heating 2 dB(A) 50 49 51 49 51
External Finish Color Munsell No 3Y 78 11
Dimensions
Wln 31-12
0 In 11-114
H In 21-58
Weight Lbs 66 80 77 80
Remote Controller Type Wireless Remote (Optional Wired Controller)
Refrigerant
Type R410A
Charge Lbs Oz 112 29
Oil Type (fl oz) NE022 (108) NE022 (152)
Refrigerant Pipe Gas Side 00 In 38 12
Liquid Side 00 In 14 14
Refrigerant Pipe Length Height Difference (Max) Ft 40
Length (Max) Ft 65 I
Connection Method IndoorOutdoor FlaredFlared
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg e) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg e) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg e) Outdoor DB 47deg F(8deg e) WB 43deg F(6deg e) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg e) Outdoor DB 17deg F(-8deg e) WB 15deg F(-9deg e) 4 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice
12 +MITSUBISHI ELECTRIC LIMITED WARRANTY ISeven-year warranty on compressor Five-year warranty on parts
- shy(MSY(Z)-D30NA MODEL SHOWN)
Vl J
09 (I)
I
N o J (I)
s Vl N Vl
-0 (I) n 31 n OJ 0 o J V)
Model Name Indoor Unit MSZ-GE18NA MSZ-FE18N MSZ-GE24NA MSZ-D30NA MSZ-D36NA
Outdoor Unit MUZ-GE18NA MUZ-FE18rK MUZ-GE24NA MUZ-D30NA MUZ-D36NA Rated Capacity Btuh 17200 18000 22500 30700 33200
Capacity Range Btuh 3700-18700 8200-25200 8200-31400 9800-30700 9800-33200
Total Input W 1640 (240-2070) 1270 (570-2280) 1800 (570- 3580) 3850 (620-3850) 4360 (620-4360) Cooling 1
Energy Efficiency SEER 192 202 190 145
Moisture Removal Pintsh 46 27 27 99 11 3
Sensible Heat Factor 071 084 075 064 062
Rated Capacity Btuh 21600 21600 27600 32600 35200
Capacity Range Btuh 3500-25200 7500-29700 7500-36900 8700-34000 8700-36000 Heating at 47deg F 2
Total Input W 1900 (230-2680) 1540 (520-2240) 2340 (520- 3650) 3360 (520-3600) 3840 (520-4100)
HSPF (Region IV) BtuhIW 10 103 10 82
Rated Capacity Btuh 13400 11700 16000 19500 21800
Heating at 17deg F 3 Total Input W 1450 2180 3290 2400 2820
Maximum Capacity Btuh 17200 19300 24600 20800 22800 Heating at 5deg F
Maximum Capacity Btuh 13562 21 600 21160 16305 19090
Power Supply Phase Cycle Voltage 1 Phase 60Hz 208230V 4
Indoor - Outdoor S1-S2 AC 208 230V Voltage Indoor - Outdoor S2-S3 DC12-24
Indoor - Remote Controller Wireless Type (Optional Wired Controller DC12V) MCA A 10 Fan Motor FLA 076
DRY (CFM) 230-275-339-420-533 388-469-628-738 388-469-628-738 389-639-848 Airilow (Cool) (Lo-Med-Hi-Super HI-Poweriul) 1
WET (CFM) 194-240-304-385-498 347-420-562-661 347-420-562-661 350-576-763
Airilow (Heat) (Lo-Med-Hi-Super HI-Poweriul) 2 DRY (CFM) 230-275-339-431-512 388-469-628-738 388-469-628-738 445-639-848
Sound Pressure Level (Cooling) (Lo-Med-Hi-Super 28-33-38-44-49 34-41-49-53 34-41-49-53 32-42-49
HI-Poweriul) 1
Sound Pressure Level (Heating) (Lo-Med-Hi-Super dB(A)
Indoor Unit 28-33-38-43-48 32-41-49-52 32-41-49-52 34-42-49-49HI-Poweriul) 2
External Finish Color Munsell No 1 OY 9202
W In 31-716 43-516 46-116
Dimension Unit D In 9-18 9-38 11-58
H In 11-5 8 12-1316 14-38
Weight Unit Lbs 22 37 40
Field Drainpipe Size OD In 58
MCA A 14 171 21
MOCP A 15 20 25
Fan Motor FLA 093
Model (Type) DC INVERTER-driven Twin Rotary
Compressor RLA 100 129 16
LRA 125 161 20
Airilow CFM 1730 1659 17691 701 1941
Outdoor Unit Refrigerant Control Linear Ex~ansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(A) 54 55 56
Sound Pressure Level at Heating 2 dB(A) 56 55 57
External Finish Color Munsell No 3Y 7811
W In 33-116
Dimensions D In 13
H In 33-716 34-58 33-716
Weight Lbs 119 141
Remote Controller Type Wireless Remote (Optional Wired Controller)
Type R410A
Refrigerant Charge Lbs Oz 3 7 43 410
Oil Type (FI Oz) NE022 (152) FV50S (135) NE022 (29)
Gas Side OD 12 58In
Refrigerant Pipe Liquid Side OD 14 38
Height Difference (Max) 50
Length (Max) Ft
100 I Connection
Mpthon IndoorOutdoor Flared Flared
NOTESTest conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg C) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F (24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F(6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 17deg F(-8deg C) WB 15deg F(-9deg C) 4 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice LIMITED WARRANTY ISeven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 13
(SEZ-KD12NA MODEL SHOWN)
SEZ HEAT PUMP TAX
CREDIT
Model Name Indoor Unit SEZ-KD09NA4 SEZ-KD12NA4 SEZ-KD15NA4 SEZ-KD18NA4
Outdoor Unit SUZ-KA09NA SUZ-KA12NA SUZ-KA15NA SUZ-KA18NA Rated Capacity Btuh 8100 11500 14100 17200
Capacity Range Btuh 3800-10900 3800-13300 3800-17000 3800-19000
Cooling 1 Total Input W 670 920 1170 1380
Energy Efficiency SEER 15 16 155 175 Moisture Removal Pintsh 15 24 26 34 Sensible Heat Factor 080 076 080 079
Rated Capacity Btuh 10900 13600 18000 21600
Heating at 4YO F 2 Capacity Range Btuh 4800-14100 4800-16400 4800-21100 4800-24900
Total Input W 1020 1140 1500 1700 HSPF(lV) BtuhIW 100 Rated Capacity Btuh 6700 9000 11900 13100
Heating at 1 yo F 3 Rated Total Input W 810 920 1200 1350 Maximum Capacity Btuh 7300 9800 13700 15000
Power Supply Phase Cycle Voltage 1 Phase 60Hz 208 230V 4 Indoor - Outdoor S1 - S2 AC 208-230V
Voltage Indoor - Outdoor S2 - S3 DC 12-24V Indoor - Remote Controller See optional accessories chart (pg 26 and 27) MCA A 1 Fan Motor FLA 051 057 074
Airflow (Lo-Med-Hi) DRY (CFM) 194-247-317 247-317-388 353-441-529 423-529-635
WET (CFM) 174-222-285 222-285-349 317 -396-4 76 381-476-572 External Static Pressure 3 In wG 002-006-014-020 Sound Pressure Level dB(A) 23-26-30 23-28-33 30-34-37 30-34-38
Indoor Unit External Finish Galvanized-Steel Sheets
W In 31-18 39 46-78
Dimension Unit D In 27-916
H In 7-78
Weight Unit Lbs 42 50 54 62 Field Drainpipe Size 00 In 1-14
MCA A 12 14
MOCP A 15 Fan Motor FLA 050 093
Model DC Inverter DC Inverter Twin Rotary
I (Type)Compressor
RLA 66 74 10
LRA 82 93 125
Airflow (CoolingHeating) CFM 11511225 12291172 1 2431 229 17301659
Outdoor Unit Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(A) 46 49 54 Sound Pressure Level at Heating 2 dB(A) 50 51 56
External Finish Color Munsell No 3Y 7811
W In 31-12 33-16
Dimensions D In 11-14 13
H In 21-58 33-716
Weight Lbs 66 77 80 119 Remote Controller Type See optional accessories chart (pg 26 and 27)
Type R410A
Refrigerant Charge Lbs Oz 116 2 9
Type (fl Oil
oz) NE022 (108)
Refrigerant Pipe Gas Side OD In 38 Liquid Side 00 In 14
Refrigerant Pipe Height Difference (Max) Ft 40 Length Length (Max) Ft 65
Connection IndoorOutdoor FlaredFlared
Method
316
NE022 (152)
12
50
100
I
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg C) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F(8deg C) WB 43deg F(6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 17deg F(-8deg C) WB 15deg F(-9deg C) 4 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
14 MITSUBISHI ELECTRIC
SEZ STATIC PERFORMANCE CURVES (SEZ-KD12NA4 MODEL SHOWN)
SEZ-KD09NA4 SEZ-KD09NA4 (External static pressure O06[inwG]) 208230V 60Hz
[020] V L
5 [016
~l [0 12
]
SEZ-KD09NA4
~ ltij
~ [008
Jj
]
]
[004J ~
V V Middle
Low
V
19h
Rated point
1
o [141] [176J 1212) )247] [282J [318]
Airll ow rat e [CFM)
SEZ-KD12NA4 (External static pressure O06[inwG]) 208230V 60Hz
[020
5 [016
]
]
[353J
Limit
]
~ V
~ [ [0 12
u ltijJ[008
[004
]
_V ]~ Low
V
k-iddle
Rated POint
o [212) [247] [2 82] [318] [353] [388]
Airtlow rate [C FM]
SEZ-KD1SNA4 (External static pressure O06[inwGl) 208230V 60Hz
[424)
1020]
5 [016
~ ~ [012
~ ltij
~ [008
Jj
J
)
]
[004 ]
o
VV V [ Low
VV
vV High
Middle
I Rated point
[282] [318) [353] [388] [424] [459] [494] [530] [565J
Airllow rat e [CFM]
SEZ-KD18NA4 (External static pressure O06[inwG]) 208230V 60Hz
50 10 20]
] 40
5 [016
s 30 [ (012 )
ltij 20 ~ [008 )~Jj
10 [004]
V
Low
v Limit
rIV High
V [ Middle
~
1
Rated point
f318) [353) [388] [424] [459] [494] [530] [565] [600] [636] [671 )
Airllow rate [CFM]
(External static pressure O14[inwG]) 208230V 60Hz 80
[0 32
70 [028
5 60 [024
20 [0 08
10 [004
]
]
J
]
]
J
]V
]
U~it
V
k
High
~V Rated POI~1 V Middle Low
~
o [141] [1 76] 12121 )247J [282] [318]
Airtlow rate [CFM)
SEZ-KD12NA4 (External stat ic pressure O14[inwG]) 208230V 60Hz
[032]
[028J
5
[353]
J
~ [024
-~ [020] V-is
J V Il Hi9h Rated point
[016
~ ]
V V1 Middle
~ [012
[008]~
[004)
o [212)
[247)
SEZ-KD1SNA4
Low r
[282] [31 8) [353]
Airllow rale [CFM]
[388]
(External static pressure O14(inwG]) 208230V 60Hz
[032J
[424
]
2 V[028
5 [024]
V-i
] V High i [020
] K
Middle Rated point [0 16
g ]
~ -
QJj [0 12
J Low
[008
] I
~
[004
o [282J [318) [353J [388J [424) [459] [4 94] [530) [565)
Airt low rate [CFM]
SEZ-KD18NA4 (External statiC pressure O14(inwG]) 208230V 60Hz
1032
1028
~ 1024
-~ [0 20
is (0 16 ltij E ~ [012
(008
(004
o
I
]
]
)
]
)vlt ]
]
~ V
VV
Low
Limit
V
Ji9h
Middle l
Rated point
1 t
1
~ [318] [353] [388] [424] [459) [4 94] [530) [565) [600] [636] [671)
Airllow rate [CFM]
(External static pressure O20(inwG]) 208230V 60Hz
[032 ]
[028 J
5 [024
~ [020
is [016
1 [012Jj
[008
[004
J
]
]
] )
]
V Low
umz V High
~V
Rated point
Middle
1
[141] [176] [212) [247) [282) [318) [353J
Airtlow rat e [CFM]
SEZ-KD12NA4 (External static pressure O20(inwG]) 208230V 60H z
[032 ] LLimit
)
[0 28
5 ]
V
[024 -~ [020] V Rated point
Highis ~
) V
bull Middle
]~V I
[016
~ ~ [012
] Low
[008
]
[0 04
o [212) [247] [282] [318] [353] [388] [424]
Airllow rate [CFM]
SEZ-KD1SNA4 (External static pressure O20(inwG]) 208230V 60Hz
80 [032 ]
70 [0 28
~ [ O~~ -
ltij
E 30 ~ [0 12
20 [008
10 [004
o
)
J
]
]
JV
J
J
Limit V
LV High
V ~
K Rated point
Middle
VV 1gt
Low
I-
~ [282) [318) (353] (388) (424) 1459] [494] 15301 [565)
Airtlow rate [CFM]
SEZ-KD18NA4 (External static pressure O20[inwG]) 208230V 60Hz
[032
[028
~ [024sect
I [020
~ [016
~ Jj [0 12
[008
[004
o
]
)
]
]
]
~ )
]
]
1V
V 1
V
Low
1 limit
~~~ I ~~ High
~ R~ted pOini
Middle
1 1 -
[31 8) [353] [388] [424) [459] [494] [530] (565) [600] (636) [671J
Airllow rate [CFM)
Vl ~ ca (I)
I
N o ~ (I)
Vl m N Vl
-0 (I) n 3-i n QJ ~ o ~ tn
Note ESP 20S230V 60 Hz See manual for Static Performance Curve including 002 in WG
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts ~MITSUBISH[ ELECTRIC 15
SLZ HEAT PUMP (SLZ-KA12NA MODEL SHOWN)
Model Name Indoor Unit SLZ-KA09NA SLZ-KA12NA SLZ-KA15NA
Outdoor Unit SUZ-KA09NA SUZ-KA12NA SUZ-KA15NA Rated Capacity Btuh 8400 11100 15000
Capacity Range Btuh 3100-10900 3100-13300 3100-22200
Cooling 1 Total Input W 700 920 1460
Energy Efficiency SEER 15 154 16 Moisture Removal Pintsh 12 23 45 Sensible Heat Factor 080 076 080
Rated Capacity Btuh 10900 13 600 18000
Heating at 4r F 2 Capacity Range Btuh 3100-14100 3100-17100 3100-17100 Total Input W 930 1180 1950 HSPF (IV) BtuhIW 96 Rated Capacity Btuh 6200 8300 10200
Heating at 17deg F 3 Rated Total Input W 740 930 1310 Maximum Capacity Btuh 8300 10200 12000
Power Supply Phase Cycle Voltage 1 Phase 60Hz 208 230V 4 Indoor - Outdoor S1 - S2 AC 208-230V
Voltage Indoor - Outdoor S2 - S3 DC 12-24V
Indoor - Remote Controller See optional accessories chart (pg 26 and 27) MCA A 1 Fan Motor FLA 023 028 028
Airflow (Lo-Med-Hi) DRY (CFM) 280-320-350 280-320-390 280-320-390
WET (CFM) 250-290-320 250-290-350 250-290-350
Sound Pressure Level dB(Al 29-32-38 30-34-39 31-35-40
Indoor Unit External Finish Galvanized-Steel Sheets Grille Munsell 64Y 8904
W In 22-7 16 (25-58)
Dimension Unit (Grille) D In 22-716 (25-58
H In 8-316 (1316)
Weight Unit (Grille) Lbs 36 (7) Field Drainpipe Size 0 0 In 1-14 MCA A 12 MOCP A 15 Fan Motor FLA 050
Model (Type) DC INVERTER-driven DC INVERTER-driven
Compressor RLA 66
LRA 82
Airflow (CoolingHeating) CFM 11511225 1 229 1 172
Outdoor Unit Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(AJ 46 49 Sound Pressure Level at Heating 2 dB(AJ 50 51
External Finish Color Munsell No 3Y 781 1
W In 31 shy12
Dimensions 0 In 11-14
H In 21-58
Weight Lbs 66 77
~e R410A
Refrigerant Charge Lbs Oz 1 16
Oil Type (fl oz) NE022 108)
Refrigerant Pipe Gas Side 0 0 In 38 Liquid Side 00 In 14
Height Difference (Max) Ft 40 Refrigerant Pipe Length
Length (Max) Ft 65
Connection Method IndoorOutdoor FlaredFlared
29
Twin Rotary 74
93
12431 229
80
NE022 l152) 12
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg C) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F(8deg C) WB 43deg F(6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 17deg F(-8deg C) WB 15deg F(-9deg C) 4 Indoor units receive power from outdoor units through field-supplied interconnectedwiring Specifications are subject to change without notice
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
16 MITSUBISHI ELECTRIC
MHK1 WIRELESS REMOTE CONTROLLER KIT Exclusive for INVERTER-driven Mr Slimreg Systems VlWireless Technology a J
JMITSUBISHI ELECTRIC
Wireless Receiver
MHK1 Kit includes
09 mMRCH1 WIRELESS REMOTE CONTROLLER I Nbull Backlit easy-to-read display o
bull Dual setpoint control with system changeover J m
bull Enabled with RedLlNKTM reliability
bull Compatible with MCCH1 Vl Portable Central Controller m
N bull Installs Anywhere Vl
MFH1 WIRELESS RECEIVER N Vlbull Required for MRCH1 Wireless
CRemote Controller m bull Enabled with RedLiNK reliability n
31 n OJ o J en
SEZ and SLZ 11 systems with SUZ outdoor unit
Function Description
ONOFF OnOff operation for a single indoor unit
Operation Mode Cool I Drying I Auto I Heat I Fan only Available operation modes dependant on connected system
Temperature Setting Set temperature from 50degF - 8rF depending on operation mode and connected system
System Changeover Deadband Value 2-8degF
Schedule Operation 5-25-1-1
Fan Speed Setting HiMid-2Mid-1 IlowlAuto Available fan speed settings dependant on connected system
Air Flow Direction Setting Air flow angles 100deg - 80deg - 60deg - 40deg and oscilate Available air flow direction settings dependant on connected system
PermitProhibit Function Individual prohibit operations for each remote controller function (ONI OFF Set Temperature and Operation Mode)
Space Temperature Displays the measured space temperature
Error Indication Displays error code
Display Outside Temperature and Humidity
Requires optional MOS1 Outside Air Sensor
Dimensions - ryv x D x H) Remote Controller 5-316 x 1-12 x 3-916 Receiver 3-14 x 1-516 x 6-716
Operating Ambient Temperature Remote Controller 32 - 120degF Receiver -40 - 165degF
Operating Ambient Humidity Remote Controller 5 - 90 RH (non-condensing) Receiver 5 - 90 RH (non-condensing)
Power Supply 2 AA batteries
MRCH1 MIFH1 MRC1
Wireless Wall-Mounted Remote Controllers Wireless Receiver Cable
Accessories MCCH1 MOS1
Portable Central Controllers Outside Air Sensor
MITSUBISHI ELECTRIC 17
MULTIPLE ROOMS WITH INDIVIDUAL CONTROL FROM A SINGLE SYSTEM Enjoy ideal levels of comfort in the rooms you use most with our multi-room system Each room (zone) operates independently People in different rooms - the kitchen master bedroom or living room - can enjoy temperature settings that make each of them most comfortable
If you re looking for a complete comfort solution for several different rooms the MXZ multi-room system is the right choice The system is flexible enough to conform to a particular cooling and heating need and offers numerous different indoor unit combinations In addition up to eight indoor units can be connected to one outdoor unit Now with a SEZ horizontal ducted unit and a MFZ floorshystanding unit homeowners can enjoy an even greater range of zoning options provided by an MXZ system
An MXZ multi-room system is an excellent choice for supplementing capacity to a current system conditioning newly furnished spaces or new additions and replacing a system within a home Homeowners can also benefit from lower energy costs year-round while staying comfortable thanks to Mitsubishi Electrics energy-efficient technologies that are a part of every system that we make
To add to the level of energy efficiency the MXZ -2B20NA and MXZ -3B24NA systems qualify for both ENERGY STARreg and the federal tax credit (See details on page 21 for applicable indoor unit combinations)
At right a single level home with several system types represented (For illustrative purposes only)
MFZ Floor-Standing Indoor Units for MXZ Heat Pump Systems
Floor-standing indoor unit mounts three inches above the floor and has front panel access to the filter for ease of cleaning
The MFZ units provide energy-efficient solutions to provide personalized comfort for difficult areas that may be smaller or dont have usable space on the walls
MFZ units on MXZ systems include the following features bull Top and bottom discharge vanes bull Hot-start technology bull Quiet operation bull Wireless remote control (optional wall-mounted controller)
18 MITSUBISHI ELECTRIC
MSZ Wall-Mounted Indoor Units for MXZ Heat Pump Systems
Providing a wide range of cooling and heating capacities each wall-mounted indoor unit mounts high on a wall and connects to a branch box or the outdoor unit by a refrigerant line run via a 3 hole The MSZ units provide highly efficient solutions to cooling and heating needs and provide personalized comfort for the individual zones in which they are installed
MSZ units on MXZ systems include the following features bull Sleek flat panel design bull Hot-start technology bull Quiet operation bull i-seeM sensor technology (MSZ-FE0912NA models only) bull Enhanced filtration system (MSZ-FE0912NA models only) bull Wireless remote control (optional wired wall-mounted controller)
SLZ Ceiling-Recessed Indoor Units for MXZ Heat Pump Systems
The new SLZ-KA ceiling casette systems offer a wide air-flow pattern for better air distribution
offered to your customers Installation can be done in a hard ceiling (with a access panel for servicing) or placed into a 2x2 drop ceiling With a built-in drain lift mechanism for condensate
removal and a 4 ventilation air intake knockout option the SLZ is ready to handle a variety of installation needs
SLZ units on MXZ systems include the following features bull Wide air-flow pattern for better air distibution bull 4 ventillation air intake knockout bull Built-in condensate lift mechanism bull Wireless RedLlNKTM remote controller
SEZ Horizontal Ducted Indoor Units for MXZ Heat Pump Systems
SEZ ducted units can provide split air-conditioning system advantages with the added benefit of being concealed to provide virtually no visual footprint within the conditioned space other than a register and grille for the air to flow With the use of short run ductwork these units can provide comfort to a single room that needs air dispersed evenly throughout the space unusually shaped rooms and adjacent rooms
The SEZ unit on MXZ systems include the fOllvowin fatures _
g~e~~~~==Zl[bull Concealed design for short-run ductwork bull Quiet operation bull Built-in condensate lift mechanism
JMITSUBISHI ELECTRIC 19
s c t
I
N o J ro o ltro ~ ro ~
DIAMOND COMFORT MXZ MULTI-ZONE SYSTEMS MXZ-B Series multi-zone systems provide personalized comfort control and energy efficiency in up to eight rooms with only a single outdoor unit The MXZ-B Series system features include
bull Individual zone control bull Mix and match flexibility of indoor unit styles and combinations bull A wide range of indoor unit capacities that match the room size and requirements bull Flexible design options to tackle the most challenging multi-room installations bull Efficient systems including three systems [mxz series] that meet energy starltID and
federal tax credit requirements bull Simple quick and cost-effective installation keeps install costs down on new construction
and disruption to a minimum on renovations and refits
Efficiency and performance ratings depend on the number style and capacity of the indoor units installed with each Multi-Zone System
MXZ -2 B20 NA - 1 (2 1 ) MXZ -3 B24 NA (2 13 1) Ou tdoo r Unit Outdoor Uni t
MSZ-GE09NA Indoor Units
SEZ-KD12NA Indoor Unit
MSZ- GE06NA
~~~~li
(At least two indoor units MSZ-GE06NAIndoor Unit must be installed) Indoor Unit
(Two indoor units must be installed )
MXZ -3 B30 NA (2 1 3 1) Outdoor Unit
SEZ-KD12NA Indoor Unit
~~~i
(At least two indoor units MSZ-GE06NA must be installed)
Indoor Unit ~
MFZ- KD12NA Indoor Unit
MXZ-8B48NA (2 1-8 1) Outdoor Unit
(At least two indoor units
must be installed)
(At least two indoor units must be installed)
MFZ-KD09NA Indoor Units
MSZ-GE09NA Indoor Units
SEZ-KD12NA Indoor Unit
MSZ INDOOR UNIT
MSZ-FE18NA
PEAD HORIZONTAL -DUCTED INDOOR UNIT
PEAD-A24AA
MSZ INDOOR UNIT SEZ HORIZONTAL-DUCTED MSZ-FE18NA
INDOOR UNIT MFZ FLOOR-STANDING SEZ-KD18NA INDOOR UNIT
MFZ-KA12NA
20 AMITSUBISHI ELECTRIC
MULTI-ROOM MXZ-8 INVERTER HEAT PUMP R
Model Name Outdoor Unit MXZ-2B20NA-1 5 MXZ-3B24NA 6 MXZ-3B30NA MXZ-4B36NA 7
Indoor Unit
Cooling 1 Non-ductedl Ducted
Rated Capacity Btuh 1800020000 2200023600 28400127400 3540034400
Capacity Range Btuh 7800-20000 12600-25500 12600-28400 12600-36400
Total Input W 2190 (630-219QL 2460 (1000-2950) 3330 l1 000-3330) 3 940 (1 000-4020)
Heating at 4JO F 2 Non-ductedl Ducted
Rated Capacity Btuh 2200022000 2500024600 2860027600 3600034400
Capacity Range Btuh 8500-25500 11400-30600 11 400-36000 11400-43000
Total Input W 2620 (520-2620) 1900 (740-2600) 2220 (740-2820) 3100 (740-3940)
Heating at 1JO F 3 Non-ductedl Ducted
Rated Capacity Btuh 1250012500 1400014000 1600015100 2220020300
Rated Total Input W 13501430 13801570 21202 140 24302340
Maximum Capacity Btu h 1450014500 1880017000 1880018000 2460025400
Maximum Total Inl2ut W 15001590 21202230 21202140 33403450
Power Supply Phase Cycle Voltage 1-phase 60Hz 2081 230V 8
Voltage Indoor shy Outdoor S1 - S2 AC 2081 230V
Indoor shy Outdoor S2 - S3 DC12-24V
Outdoor Unit 4
MCA A 15 19
MOCP A 20
Fan Motor FLA 096 093
Compressor
Model (Type)
DC INVERTER-driven Twin Rotary
RLA 101 11 144
LRA 15
Airflow (CoolingHeating) CFM 14851 640 20681605 13651605 20682068
Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1
dB(A) 49 54 49 54
Sound Pressure Level at Heating 2
dB(A) 51 49 57
External Finish Color Munsell No 30Y 781 1
Dimensions
W In 33-116 35-716
D In 13 12-58
H In 27-1516 35-7116
Weight Lbs 130 150 153
Indoor Unit No of Units 2 23 23 234
Remote Controller Type Associated with the Indoor Unit
Refrigerant
Type R410A
Charge Lbs Oz 515 7 11 813
Oil Type (fl oz)
NE022 (237) NE022 (294)
Refrigerant Pipe Gas Side 00 In AB 38 A 12 BC 38 A 12 BCD 38
Liquid Side 00 In 14
Refrigerant Pipe Length Height Difference (Max) Ft 4933 9
Length (Max) Ft 164 (A+B) 230 (A+B+C) 230 (A+B+C+D)
Connection Method IndoorOutdoor FlaredlFlared
Compatible with the MSZ-A MSZ-GA MSZ-FD MSZ-FE MSZ-GE MFZ-KA and SEZ-KD series indoor units (PLA-18 amp PCA-24 on the MXZ-MXZ-3B PLA-24 amp PCA-24 on the MXZ-4B)
NOTES Test conditions are based on AHRI 210240 One indoor unit is turned off during low-speed testing under the new test conditions Systems actually exhibit higher energy efficiencies during normal operation
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F (35deg C) WB 75deg F (24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F (6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 600 F (160 C) Outdoor DB 17deg F (_80 C) WB 150 F (_90 C) 4 Refer to pages 12 and 13 for Indoor Unit specifications 5 Data from combination of two Indoor Units 9000 Btuh (non-ducted) or one 9000 Btuh and one 12000 Btuh (ducted) 6 Data from combination of two Indoor Units 6000 Btuh and one 9000 Btuh (non-ducted) or three 9000 Btuh (ducted) 7 Data from combination of four Indoor Units 9000 Btuh (non-ducted and ducted) 8 Indoor units receive power from outdoor units through field-supplied interconnected wiring 9 49 Applies to installations where the outdoor unit is installed below the indoor unit
Power factor equals 97 percent
Specifications are subject to change without notice
MULTI-ZONE ENERGY STAR AND TAX CREDIT SYSTEMS
Model Indoor Unit Combinations SEER HSPF
MXZ-2B20NA-1 2 x MSZ- GE09NA 18 8 9
MXZ- 3B24NA 2 x MSZ- GE06NA 1 x MSZshy GE09NA
17 5 9 3
MXZ- 3B24NA 2 x MSZ-GE06NA 1 x MSZ- GE12NA
17 5 93
For more details on all ENERGY STAR and tax credit systems go to wwwmitsubishicomfortcomtaxcredit
See page 25 for additional info on efficiency
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 21
MXZ-8B48NA THE ULTIMATE ZONING SOLUTION
The Mitsubishi Electric MXZ-S84SNA eight-zone unit As a member of the expanding MXZ-B Series of multi-zone systems the MXZ-8B outdoor unit incorporates branch boxes to connect up to eight indoor units MXZ- 8 B48 NA (2 1 - 8 1 )
Outd oor Uni t The INVERTER-driven compressor at the heart of the MXZ-8B -~-- shy
outdoor unit provides variable capacity control allowing the system to adjust to the specific demands of the interior space ~ as needed not the hard start and stop of a traditional system I[iDA Jinstalled in most US homes
The MXZ -8B48NA has only one port on the outdoor unit for two insulated refrigerant lines which run into the home or business to connect to a branch box or boxes From the branch box(es) gas and liquid refrigerant piping run to each of the indoor units The LEV in the branch box(es) controls the refrigerant flow as the load of each zone changes
Through the branch box(es) (the PAC-AKA31 BC three-port andor the PAC-AKA51 BC five-port) the system can connect from two indoor units up to eight indoor units depending on application requirements
The flexibility of the system doesnt stop there The MXZ-8B48NA has rated capacities of 48000 Btuh for cooling and 54000 Btuh for heating System operation however can range from a minimum 12000 Btuh to a maximum 54000 Btuh in cooling and a maximum of 60000 Btuh in heating This type of performance supports a large variety of applications
The MXZ-8B48NA allows for further flexibility because it supports a connected indoor unit capacity from 22 to 130 or 12000 Btuh to a maximum 70200 Btuh depending on diversity
Connectable Indoor Units General Features bull Four-ton outdoor unit can support up to
eight indoor units using branch boxes bull Wide variety of indoor unit styles
-=--_-=-----= - - J _ 1
including wall-mounted floor-standing MSZ-FE09 12 18NA MSZ-GE06 09 12 15 18 24NA ceiling-cassette ducted
bull Individual control up to eight (8) zones using wired or wireless controls
bull Advanced microprocessor control bull Auto restart following a power outage bull Self-check function offering SEZ-KD09 1215 18NA PEAD-A24AA
integrated diagnostics ~--- Jbull Limited warranty five years on parts and
defects and seven years on compressors
SLZ-KA09 1215NA MFZ-KA09 12 18NA
22 MITSUBISHI ELECTRIC LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
I
RMULTI-ROOM MXZ-8 INVERTER HEAT PUMP
Model Name Outdoor Unit MXZ-BB4BNA Cooling 1 Rated Capacity
Non-ducted Rated Total Input Ducted
Maximum Capacity
Rated CapacityHeating at
Rated Total InputIndoor Unit 4JO F 2 Non-
ductedDucted Maximum Capacity
Rated Capacity Heating at
Rated Total InputlJO F 3 Non-ductedDucted Maximum Capacity
Power Supply Phase Cycle Voltage
Indoor - Outdoor Sl - S2 Voltage
Indoor - Outdoor S2 - S3
MCA
Recommended FuseBreaker Size
Fan Motor
Compressor
Airflow (CoolingHeating)
Refrigerant Control
Outdoor Unit Sound Pressure Level at Cooling 1
Sound Pressure Level at Heating 2
External Finish Color
Dimensions
Weight
Total Capacity 22-130
Indoor Unit ModelQuantity
Remote Controller Type
Type
Refrigerant Charge
Oil
Gas Side OD Refrigerant Pipe
Liquid Side OD
Height Difference (Max)
Maximum Distance between (Outdoor unit and farthest indoor unit)
Refrigerant Pipe Length Maximum Pipe Length -Branch box to Indoor Unit
Total Maximum line length between Branch Box and All Connected Indoor Units
Total Length (Max)
Connection Method IndoorOutdoor
Includes both branch boxes if there are two
Branch Boxes (At least one branch box required)
Btuh
W
Btuh
Btuh
W
Btuh
Btuh
W
Btuh
A
A
Type x Quantity
Motor Output (kW)
Model (Type)
Motor Output (kW)
CFM
dB(A)
dB(A)
W In
D In
H In
Lbs
Btuh
Lbs Oz
Type (fl oz)
In
In
Ft
Ft
Ft
Ft
Ft
4800048000
57806470
54000
5400054000
48205270
60000
3300034700
29503390
3660036550
1 Phase 60Hz 208 230V
AC 208-230V
DC12-24V
32
40
Propeller x 2
0086 + 0086
DC INVERTER-driven Scroll
29
3530
Linear Expansion Valve
54
55
Munsell No 3Y 78 11
37-716
13+1-3 16
53-3 16
278
12000 - 70200
600 - 24000 2-8
Associated with Indoor Unit Model
R410A
18 112
FV50S (73)
58
38
6698 4
230
49
197
377
FlaredFlared
Compatible with the MSZ-A MSZ-FO MSZ-FE MSZ-GE MFZ-KA SEZ-KD PLA and PEAD series indoor units
NOTES Test conditions are based on AHRI 210240 One indoor unit is turned off during low-speed testing under the new test conditions Systems actually exhibit higher energy efficiencies during normal operation
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F (35deg C) WB 75deg F (24deg C)
2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 4]0 F (8deg C) WB 43deg F (6deg C)
3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 17deg F (-8deg C) WB 15deg F(-9deg C)
4 66 applies to installations when the outdoor unit is installed below the indoor unit
Power factor equals 97 percent
Specifications are subject to change without notice
Note Maximum installed capacity is the maximum total of all connected indoor units NOT the maximum capacity produced
Only a single Lineset is needed from the outdoor unit to branch box
See page 25 for MXZ-B information on efficiency
Required Branch Boxes for MXZ-SB4BNA (Maximum of 2 branch boxes can be connected to one outdoor unit requires joint MSDD-50AR-E or MSDD-50BR-E)
s c d N o J ro Vl
0 ro n 3i n OJ d o J U)
PAC-AKA51 BC Branch Box
PAC-AKA31 BC Branch Box LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 23
MSZ WALL-MOUNTED INDOOR UNITS (FOR MXZ-8 OUTDOOR UNITS)
R
(MSZ-GE12NA MODEL SHOWN)
-000 IIIIIII 9000 9000 12000 12000 14000 17200
Heating at 4r Rated Capacity Btuh 7200 10900 10900 14400 13600 18000 21600
F2 Power Supply I Phase Cycle Voltage J -phase 60Hz 208 230V 3
Iindoor Outdoor S1 S2 AC 208 230V
Iindoor Outdoor S2 S3 DC12-24V Voltage
Iindoor Remote vomr Iller Wireless Type (Optional Wired vomroller DC 12V)
IMCA A 10 IFan Motor FLA 076
DRY 162-226shy145-170shy
162-226shy205-272shy 230-275shy
Airflow at Cooling (CFM)
145-170-237-321-399 339-381
237 -321shy381-410
335-420shy 339-420shy(Quiet-Lo-Med-Hishy 399 533 533 Super Hi or Lo-Med-
WET 144-202shy109-134shy
144-202shy170-237shy 194-240shy
Fan Hi-Powerful)1 (CFM)
109-134-201-286-364 307-343
201-286shy350-367
300-385shy 304-385shy364 498 498
Airflow at Heating 145-170shy 145-170shy 145-170shy 205-247shy 230-275shy
(Quiet-Lo-Med-Hi- WET 233-321shy 237-321shy
166-240shy237-321shy
166-240shy304-367shy 339-431shy
Super Hi or Lo-Medshy (CFM) 406 406
367 -381 406
399-420 463 512
Hi-Powerful) 2 Sound Pressure Level at Cooling
19-22-30shy 26-32-38shy 28-33-38shy(Quiet-Lo-Med-Hi-Super Hi or Loshy dB(A) 19-22-30-37 -43 22-31-39-42
37-45 22-33-43-45
44-49 44-49Med-Hi-Powerful) 1
Sound Pressure Level at Heating 19-22-30shy 26-30-35shy 28-33-38shy
(Quiet-Lo-Med-Hi-Super Hi or Loshy dB(A) 19-22-30-37 -43 22-31-40-42 37-43
22-23-43-44 40-46 43-48
Med-Hi-Powerful) 2
I External Finish Color Munsell No 10Y 92 02
IWln 31 middot716
Dimension Unit 10 In 9 18 10-18 9middot18 10-18 9-18
IH In 11-58
I Weight Unit ILbs 22 27 22 27 22 I Field Drainpipe ~D lin 58 Remote Con-
Type Wireless Remote (Optional Wired Controller) troller
ITvpe B41QA Refrigerant ~s$ideOD lin 38 Pipe I Liquid Side 00 In 14
Connection IndoorOutdoor FlaredFlared
Method
1~
II 18000 22500
21600 27600
388-469shy 38$-469shy628-738 628-738
347-420shy 347-420shy562-661 562-661
388-469shy 388-469shy628-738 628-738
34-41-49-53 34-41-49-53
32-41-49-52 32-41-49-52
43-516
9-38
12-1316 37
58 38
MXZ-2B20NA is also compatible with the MSZ-A and MSZ-FD series indoor units NOTES Test conditions are based on AHRI 210240
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F(6deg C) 3 Indoor units receive power from outdoor units through field-supplied wiring
Specifications are subject to change without notice LIMITED WARRANTY Seven-year warranty on compressor Five-year warranty on parts For data on specific indoor unit combinations see page 21
SEZ DUCTED INDOOR UNIT (FOR MXZ-8 OUTDOOR UNITS)
I
Notes 1 Cooling-Indoor DS 80deg F(267deg C) WS 67deg F(194deg C) Outdoor DS 95deg F (35deg C) WS 75deg F(239deg C)
2 Heating-Indoor DS 70deg F(211 deg C) WS 60deg F(156deg C) Outdoor DS 47deg F (83deg C) WS 43deg F(61 deg C)
3 External static pressure is factory set to 006 WGAdjustable via the
1---------t---+-----L-------------1~---__I PAR-21MAA
1--_____----__________+-____---L____----~_____________1 4 Indoor units receive power
jE~~~~-------------r----1-----~-~~~~~~~~-----___1 from outdoor units through fieldsupplied interconnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven-year warranty on compressor Five-year
1---------------------+---+------------------------1 warranty on parts
~--__I_~----------+-------~l----------I For data on specific indoor unit combinations see page 21 - 23
I--~------+~-----------~----------r_------------I
- Reference page 17 for SEZ static performance curves
24 MITSUBISHI ELECTRIC
25-30-35-40 26-31-36-41 35-38-42-46
25-30-35-40 28-31-36-41 35-38-42-47
MFZ FLOORLOW WALL INDOOR UNIT (FOR middotMXZ-8 OUTDOOR UNITS)
------shy
-==
Airflow at Heating (CFM) 177-198-219-332 184-201-219-335 261-275-297-434
Voltage
Fan
Airflow at Cooling (Lo-Med-Hi-Super Hi)1
169-205-251-314 251-279-325-394
163-197-241-303 170-207-252-309 241-269-313-379
(Lo-Med-Hi-Super Hi) 2
SLZ CEILING-RECESSED INDOOR UNIT (FOR MXZ-8 OUTDOOR UNITS) EFFICIENCY RATINGS
Voltage
Fan
Galvanized-steel SheetsMunsell 64Y 89 04
Refrigerant Pipe
Model Indoor Unit Type SEER HSPF
MXZ-2B20NA-1
Non-dueted 18 89
Dueted and Non-dueted 1675 87
Dueted 155 85
MXZ-2B20NA-1 ENERGY STAR amp
TAX CREDIT 2 x MSZ-GE09NA 18 89
MXZ-3B24NA
lJon-dueted 175 93
Dueted and Non-dueted 1625 89
Dueted 150 85
MXZ-3B24NA ENERGY STAR amp
TAX CREDIT
2 x MSZ-GE06NA 1 x MSZ-GE09NA
175 93
MXZ-3B24NA ENERGY STAR amp
TAX CREDIT
2 x MSZ-GE06NA 1 x MSZ-GE12NA
175 93
MXZ-3B30NA
Non-dueted 175 105
Dueted and Non-dueted 16 100
Dueted 145 95
MXZ-4B36NA
Non-dueted 18 93
Dueted and Non-dueted 16 5 92
Dueted 150 9 0
MXZ-BB4BNA
Non-dueted 15 87
Dueted and Non-dueted 14B B8
Dueted 147 89
Connection IndoorOutdoor FlaredFlared
Method
Notes 1 Cooling-Indoor DB 80deg F(267deg C) WB 67deg F(194deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(239deg C) 2 Heating-Indoor DB 70deg F(21 1 deg C) WB 60deg F(156deg C) Outdoor DB 47deg F(83deg C) WB 43deg F(61 deg C) 3 Indoor units receive power from outdoor units through field supplied interconnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 25
Notes 1 Cooling-Indoor DB 80deg F(267deg C) WB 67deg F (194deg C) Outdoor DB 95deg F (35deg C)WB 75deg F (239deg C)
2 Heating-Indoor DB 70deg F(211deg C) WB 60deg F (156deg C) Outdoor DB 47 F (83deg C) WB 43deg F (61 deg C)
3 Indoor units receive power from outdoor units through field supplied interco(lnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven -year warranty on compressor Five-year warranty on parts
Presently there is no 1 1 system with the MFZ indoor unit
s c
N o J ro Vl
C ro n ~ n OJ t o J V)
M-SERIES RATING CONDITIONS
INDOOR INTAKE AIR TEMPERATURE
OUTDOOR INTAKE AIR TEMPERATURE
COOLING
MAXIMUM
95degF DB 71 degF WB (MU SUZ MXZ-2B20-13B243B304B36) 90degF DB 73degF WB (MUZY-GE MUZ-FE MUzy-D)
115degF DB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B24 3B304B368B48)
MINIMUM 67degF DB 57degF WB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B201 3B243B304B36)
14degF DB (MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B24 3B304B36) 23degF DB (MXZ-8B48) 6rF DB (MU)
MAXIMUM 80degF DB 6rF WB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B243B304B36)
75degF DB 65degF WB (MUZY-GE MUZY-GA24 MUZ-FE SUZ MXZ-2B20-1 3B243B304B36) 70degF DB (MXZ-8B48)
HEATING
MINIMUM 70degF DB 60degFWB (MUZ-GE MUZ-GA24 MUZ-D MUZ-FE SUZ MXZ-2B20-1 3B243B304B36)
-13degF DB -15degFWB (MUZ-FE) -4degF DB -5degF WB (SUZ MUZ-GE) 5degF DB 4degF WB (MUZ-GA24 MXZ-8B48NA) 6degF DB 5degF WB (MXZ-2B20-1 3B24 3B304B36) 14degF DB 13degFWB (MUZ-D)
MU units operate at intake air temperature down to 10deg Fwith the addition of an ICM-326HM-1 low temperature control
REFRIGERANT TUBING SETS
OPTIONAL ACCESSORIES
REFRIGERANT LINE LENGTH FLARE FLARE _INDOOR UNIT OUTDOOR UNIT
MS-A09WA MU-A09WA 35 MS-A12WA
65 MU-A12WA 35
MSY-GE09NA 65
MUY-GE09NA 40
MSY-GE12NA
65
MUY-GE12NA 65 40
MSY-GE15NA MUY-GE15NA 40
MSY-GE18NA
65
MUY-GE18NA 100 50
MSZ-GE09NA MUZ-GE09NA 65 40
MSZ-GE12NA MUZ-GE12NA 40
MSZ-GE15NA
65
MUZ-GE15NA 40
MSZ-GE18NA
65
MUZ-GE18NA 100 50
MSY-GE24NA MUY-GE24NA 100 50
MSZ-GE24NA MUZ-GE24NA 100 50
MSY-D30NA MUY-D30NA 100 50
MSZ-D30NA MUZ-D30NA 50
MSY-D36NA
100
MUY-D36NA 50
MSZ-D36NA
100
MUZ-D36NA 100 50
MSZ-FE09NA MUZ-FE09NA 40
MSZ-FE12NA
65
MUZ-FE12NA 40
MSZ-GE06091215NA MSZ-FE0912NA
65
MXZ-2B20NA-1 164 4933MFZ-KA0912NA SEZ-KD09 1215NA
MSZ-GE0609 121518NA MSZ-FE091218N MFZ-KA09 1218NA MXZ-3B24NA 164 4933 SEZ -KD09 12 15 18NA SLZ-KA09 12 15NA
MSZ-GE0609 121518NA MSZ-GA24NA MSZ-FE091218NA
MXZ-3B30NA 4933230MFZ-KA091218NA SEZ -KD09 121518NA SLZ-KA09 12 15NA
MSZ-GE0609121518NA MSZ-GE24NA MSZ-FE09 12 18NA
MXZ-4B36NA 230 4933MFZ-KA091218NA SEZ -KD09121518NA SLZ-KA09 12 15NA
MSZ-GE0609 12 15 18NA MSZ-GE24NA MSZ-FE09 12 18NA
MXZ-8B48NA 6698377MFZ-KA091218NA SEZ-KD09121518NA SLZ-KA09 12 15NA
PART NUMBER I USE WITH I DESCRIPTION
Port Adapters and Connection Pipes MAC-A454JP-E MXZ-Series Adapter 38 X12
MAC-A455JP-E MXZ-Series Adapter 12 X38
MAC-A456JP-E MXZ-Series Adapter 12 X58
MSDD-50AR-E MXZ-Series Branch Box Tee Distribution Pipe - Flare Connection between two branch boxes
MSDD-50BR-E MXZ-Series Branch Box Tee Distribution Pipe - Braze Connection between two branch boxes
PAC-493PI MXZ-Series Adapter 14 X38
PAC-SG76RJ-E MXZ-Series Adapter 38 X58
OPTIONAL ACCESSORIES CONTINUED ON NEXT PAGE
49 amp 66 applies to installations in which the outdoor unit is installed below indoor unit26 MITSUBISHI ELECTRIC
OPTIONAL ACCESSORIES (CONTINUED)
PART NUMBER USE WITH DESCRIPTION Control Options and Accessories
M21 JKO 307 M-Series Indoor Units Remote temperature sensor for M-Series indoor units
MAC-397IF-E
MAC-399IF-E
PAC-YU25HT
PAR-21 MM-G
M-Series INVERTER Units
M-Series INVERTER Units
SEZ-KD Indoor Units
Use with P-Series SEZ and for wired M-Series Controller
MA and contact terminal interface - Required to use PAR-21 MM wired wall mount controller with M-Series Systems
CMCN M-NET control adapter I Interface for Mr Slim M-Series MSYZ SEZ I MFZ
External Fan I Heater control relay adapter
Deluxe MA remote controller (Requires MAC-397IF-E for use with M-Series - MSYZ MFZ)
SEZ Wireless remote controller for SEZ units (Requires signal receiver PAR-SA9FA-E)PAR-FL32MA
PAR-SA9CA-E SEZ Wireless signal receiver for SEZ
3-pole disconnect switch 30A 600V turns off power between indoor and outdoor units shyM-SeriesTAZ-MS303
mounts in 2 X 4 utility box and requires standard single gang switch platecover - Low Ambient
ICM-326HM-2 M-Series Non-INVERTER units Low ambient head pressure controller MUZ-GE091215 IVIUZ-FE0912 SUZ-KD091215
Drain pan heaterMAC-640BH-U outdoor unit
MAC-641 BH-U MUZ-GE18 SUZ-KD18 outdoor unit Drain pan heater Filters
MAC-1415FT-E Anti-allergy enzyme filter
MAC-2300FT
MSZlMSY-D3036
Anti -allergy enzyme filter
MAC-308FT
MSYMSZ-GA24
MSZ-FD912 I FE0912 Platinum deodorizing filter
MAC-408FT-E Anti-allergy enzyme filter
MAC-415FT-E
M-Series Indoor Unit - GE09GE12GE15GE18
MFZ-KA Air Cleaning FilterAnti-Aliergy Enzyme Filter
MAC-418FT Anti-allergy enzyme filter
Filter Boxes
FBL1-1
MSZ- FD912 I FE091 2
FB Series Filter Box for SEZ-KD09NA Optional filter box with MERV 8 filters
FB Series Filter Box for SEZ-KD1215NAFBL1-2 Optional filter box with MERV 8 filters
and PEA-A 12M
FBL1-3 FB Series Filter Box for SEZ-KD18NA Optional filter box with MERV 8 filters
Pumps
SI1730-230 MSYZ - 30000 Btuh or greater Sauermann mini condensation pump 230V
S13100-115 MS-Series - non-INVERTER Sauermann mini condensation pump 115V
S13100-230 Sauermann mini condensation pump 230VMSYZ - Less than 30000 Btuh
Miscellaneous BRP-1 Bottom Return Plate for SEZ-KD09NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-2 Bottom Return Plate for SEZ-KD12KD15-NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-3 Bottom Return Plate for SEZ-KD18NA Converts low profile ducted indoor unit from rear return to bottom return
BV12FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderreglnsulated - 12
BV14FSI Use with any Mr Sl im multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 14
BV38FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 38
BV58FSI Use with any IVIr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 58
Condensing unit wall mounting brackets (set of 2) - 440 lb capacity painted steel NOTE CWMB1 IVIU and PU outdoor units Installer is responsible to select and provide suitable hardware and materials to insure proper
mount of bracket to wall
DSD-400N M-Series DiamondBacktrade Platform Stands MUZ-GE18 I MUZ(y)-03036 I
MAC-811DS Drain socket assemblySUZ-KA18
MAC-851DS MUZ-FD0912 Drain socket
MAC-855SG M-Series Air outlet guide
MAC-856SG M-Series Air outlet guide - MXZ-3B24 I 3B30 I 4B36 NA
MAC-860DS MUZ-GE091215 I MUZ-FE0912 Drain socket
MAC-889SG M-Series Air outlet guide- MXZ-2B20NA
MAC-S99SG M-Series Air outlet guide
PAC-SG59SG-E IVIXZ-SB4SNA Air outlet guide (1 piece) I MXZ-SB48NA (Requires 2 pieces)
PAC-SG61 DS-E MXZ-8B4SNA Drain socket - connector
PAC-SG64DP-E MXZ-SB48NA Drain pan
RCMKP1CB lVI-Series Wireless Lockdown bracket for remote controller
lILTRILlTE1 All M-Series Condensing unit mounting pad 16 x 36 x 3
MITSUBISHI ELECTRIC 27
MXZ-8 Series Port Adapter chart Port Adapter Unit Port
Combinations Required Size
MXZ-2B20NA-1
2-zone combinations wi NA
A 38 x both units s12K 14
1-MAC-A454JP-E B 38 x
6+15 14
9+15 1-MAC-A454JP-E
MXZ-3B24NA
All rated 2-zone combina-NA
A 12 x tions 14
All rated 3-zone combina-NA
B 38 x tions 14
C 38 x 14
MXZ-3B30NA
2-zone combinations wi at NA
A 12 x least one unit s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
9 + 24 14
3-zone combinations wi 1-MAC-A455JP-E
all units s12K
All other rated 3-zone NA
comb
MXZ-4B36NA
2-zone combinations wi at NA
A 12 x least one un it s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
6 + 24 14
1-MAC-A456JP-E D 38 x
9 + 24 14
3-zone combinations wi at NA
least two units s12K
3-zone combinations wi 1-MAC-A454JP-E
two units15K
6+6+24 or 6+9+24 1-MAC-A456JP-E
9+9+24 1-MAC-A456JP-E
4-zone combinations wi at 1-MAC-A455JP-E
least three units s12K
6+6+15+15 1-MAC-A454JP-E
6+6+15+15 1-MAC-A454JP-E
Note When using the Pu-A24BA PCA-A24KA or PEAD-A24AA two port adapter will be needed 1-MAC-A456JP-E (12 x 58) A port or 1-PACshySG76RJ-E (38 x 58) B C and D ports and 1-PAC493PI (14 x 38)
28 JMITSUBISHI ELECTRIC
6+6+246+9+24 6+12+249+9+24 9+12+24 or 12+12+24
6+15+24 6+18+24 9+15+249+18+24 12+15+24 or 12+18+24
15+15+24 15+18+24 or 18+18+24
15+24+24 or 18+24+24
Combinations of 4 or more zones
1-PAC-SG76RJ-E
See notes for application below
2
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
See notes for application below
PORT A =38 gas x 14 liquid
PORT B =38 gas x 14 liquid
PORT C =38 gas x 14 liquid
PORT A =38 gas x 14 liquid
PORT B = 38 gas x 14 liquid
PORT C = 38 gas x 14 liquid
PORT D =38 gas x 14 liquid
PORT E =12 gas x 14 liquid
Notes for application bull Check the lineset sizes for your indoor selected models bull Select the branch box or boxes needed for your application bull Compare indoor unit lineset sizes as compared to branch
box sizes bull Connect 15K + indoor units to the larger port on the
(PAC-AKA51 BC) bull Adapt lineset size with appropriate port adapter from
above list bull When using the PU-A24BA or PEAD-A24AA two port
adapter will be needed 1-MAC-A456JP-E (12 x 58) or 1-PAC-SG76RJ-E (38 x 58) and 1-PAC493PI (14 x 38)
-fv
~ DIAMONDBACKtrade
~) BV-Series Ball Valves Model numbers
BV14FFSI BV38FFSI
LISTED 891N REFRIGERANT
BV12FFSI VALVE bull Engineered for Mini-split andBV58FFSI
Multi-split HVAC Units bull Size available 14 38 12 58
bull Full Port Designbull Fully factory assembled bull Furnace brazed and pressure tested bull 700 PSIG Rated bull Each ball valve is equipped with Schraderreg Valve
for refrigerant service bull R-410A Compatible bull Design working pressure 700 PSIG bull Temperature range bull Flare Connections
-40 0 F to +3250 F (-400 C to + 1490
C) bull Forged brass body and seal cap bull Teflonreg seals and gaskets (no synthetic a-rings) bull Seal cap design permits valve operation without
removal of seal cap bull Suitable for use with R-11 R-22 R-123 R-125
R-134A R-236FA R-4202A R-402B R-404A R-407C R-410A R-500 R-502 and R-507
bull One year limited materials and workmanship
Part Number SAE Flare
A B C 0 E F
BV14FFSI 14 619 260 180 122 142 110
BV38FFSI 38 630 267 180 122 142 110
BV12FFSI 12 651 267 180 122 142 110
BV58FFSI 58 664 267 180 128 142 110
Ball valves come With an insulation piece warranty on Ball Valves
~ DIAMONDBACKtrade
~) Platform Stands
Lift the Mitsubishi Electric Comfort Solution
outdoor unit to new heights with our Diamondback Platform Stands
bull Easy to install
bull Available for all sizes of Mr Slim outdoor units
bull Color matched to the outdoor units
Model Number DSD-400N
L 15-34 x W 3-14 x H 3-14
r
)MITSUBISHI ELECTRIC 29
~ DIAMONDBACKtrade LINESETS
~~
Twin-Tube Lineset Insulation Design
bull Balanced outside diameter for uniform coiluncoil position stability
bull Minimum 12 insulation thickness on both tubes Diamondback Advantages include the following features
bull Quick efficient and economical field installation using factory applied Twin Tube insulation and flare connections with flare nuts mounted
bull Correct lengths for reducing waste and time
bull Quality consistency and economy
bull All Diamondback Lineset tubing is tested in accordance with ASTM E243
Filter Boxes
FB Series filter boxes are available in compatible sizes for all Mr Slim horizontal ducted indoor units
FBL 1 filter boxes include 1 thick pleated MERV 8 filter(s) installed Filters are tested in accordance with ANSIASHRAE Standard 522 and Rated Class 2 under UL Standard 900
The cabinet is constructed of non-insulated 20 gauge G-60 galvanized
FBL1-1 FB Series Filter Box for SEZ-KD09NA
FBL1-2 FB Series Filter Box for SEZ-KD12KD15-NA
FBL1-3 FB Series Filter Box for SEZ-KD18NA
steel with foam gasket and provides an air-tight connection to indoor unit and access door Gasket material complies with UL 723 requirements
A screw-through cabinet design for secure attachment to indoor unit and return connection in rear is easily field-converted to bottom return
30 MITSUBISHI ELECTRIC
bull
bull
bull
bull
bull
bull
LINE-HIDE~ Put a professional finish on air-conditioning
installations with an easy-to-install modular
system that beautifies exteriors and
protects Linesets drainlines and wiring
Can be use it indoors too Meets UL94v-O for interior applications
Has snap-on covers and a full selection of couplings elbows T-joints caps and more for any application complex or simple
Offers high-quality PVC with UV inhibitors for outdoor service in all weather conditions
Can be painted with most house paints to match exterior decors
Is not just for HVAC Hide any exterior cabling piping or wiring
Available in four sizes 2-14 3 4 and 6 tubes
Download a brochure at wwwline-hidecom to find out more information
For more information on our CITY MULTI VRF product line visit our website at wwwmitsubishiprocom
_lIJrUlllln ~ ~IIII1 fInll l
~
l bull bull
JMITSUBISHI ELECTRIC 31
---- -- -- -
System Lineup RESIDENTIAL AND LIGHT COMMERCIAL SYSTEM MODELS AND CONTROLLERS
SINGLE
MSMU Air Conditioners
9500 to 12000 Btuh 13 SEER
bull Provides cooling-only system bull Non-INVERTER rotary compressor bull Ideal for spaces such as
bedrooms garages out-buildings video monitoring
- ROOM WALL-MOUNTED Ale (cooling only)
MSYMUY Air Conditioners
3800 to 34600 Btuh Capacity Range 151 - 21 SEER
~ -
bull Cooling-only system bull INVERTER-driven compressor bull WIDE VANE for a wider angle of airflow 150
0
from left to right (on GE24D30D36 models)
bull Ideal for spaces such as bedrooms garages large open rooms and bonus rooms
SINGLE-ROOM WALL-MOUNTED HEAT PUMPS (coo lin g and heatin g)
MSZMUZ Heat Pumps
3800 to 33200 Btuh Capacity Range
145 - 21 SEER 82 - 10 HSPF
bull Uses INVERTER-driven compressor bull Provides cooling and heating in a wide range
of capacities bull Offers a WIDE VANE for a wider angle of airflow 1500 from
left to right (on GE24D30D36 models) bull Ideal for applications in bedrooms home offices living
rooms dining rooms bonus rooms basements kitchens guard houses and more
Up to 26 SEER
MSZMUZ-FE0912NA High - Efficiency Heat Pumps
2800 to 25200 BtuH capacity range 202 - 26 SEER
10 - 106 HSPF
bull INVERTER-driven compressor bull Quiet operation as low as 19dB(A) bull i-seetrade Sensor technology bull Enhanced filtration system bull H2ireg high~heat capabilities (see page 12 amp13)
MSZ-FE09 is 100 percent at 50 F MSZ -FE12 is 92 percent at 50 F MSZ-FE18 is 100 percent at 50 F
SI NGLE-ROOM LOW WALL or FLOOR-STANDING UNIT (fo r use with MXZ -8)
New to our lineup is a Low Wall or Floor-Standing model that can fit into those once difficult installations
MFZ These units provide comfort in spaces such as (For use with MXZ-8 finished attics with knee walls basements with Outdoor Units only) low ceilings and glass-walled sunrooms
bull Provides cooling and heating in Mounted three inches above floor level these models a wide range of capacities provide conditioned air two vents and provide direct
bull Two outlet air vents front-panel access to the filter for easy cleaning The - Upper vent for cooling or heating MFZ can even be recessed in a wall during installation - Bottom vent for heating only provided proper clearances are maintained (Currently there is
bull Flush or recessed installation no 1 1 system with M FZ)
8 MITSUBISHI ELECTRIC
SING LE -ROOM HORIZONTAL- DUCTED HEAT PUMPS (coo lin g and heat ing)
WIR ELESS and W IR ED REMOTE C O NTRO LLERS
PAR-21 MAA Wireless remote controller Set Temperature
for wall-mounted and floor-standing indoor units ----- OnOff
Timer Menu Fan Speed
Fan Speed Filter
Test Run Set Time
CheckEcono Cool
Airflow UpDown Timer OnOff
Louver
Ventilation
Reset ---- shy Optional wired controller for the SEZ SLZ and MFZ indoor units (Optional controller for wall-mounted is
available and floor-standing indoor units Unit requires MAC-397 If adapter)
MHK1 WIRELESS REMOTE CONTROLLER Exclusive for INVERTER-driven Mr Slimreg Systems
Wireless Technology a SEZ and SLZ 11 systems with SUZ outdoor unit only
MIFH1
MITSUBISHI ELECTRIC 9
AMITSUBISHI ELECTRIC
l~ 1000
~r t ~~~O
MRCH1
rtj n-shy --1r-a-1-shy
Mode ------ -- shy
SEZSUZ If your customer is looking for discrete zoned comfort then a short-run ducted unit Heat Pumps is the right solution As a stand-alone system or connected to a MXZ multi-room
3800 to 19000 BtuH system the SEZ ducted units provide energy efficiency quiet operation and a Capacity Range compact design for quick easy instqllation hidden either in the ceiling or beneath
15 SEER _---~~mm the floor 175 - 10 HSPF
J ~ All of the 11 systems are ENERGY STAR certified and two systems qualify for
~ the federal tax credit These systems provide customers with an environmentally friendly indoor unit with a similar installation and familiar style
These SEZ indoor units also connect to MXZ multi-zone systems providing a wide array of installation options to best fit any application
SING LE -R OO M C EI LING -REC ESSED CASSETTE UN IT
SLZSUZ Heat Pumps The SLZ -KA ceiling-recessed units casette offer a wide
3100 to 22200 BtuH air-flow pattern for better air distribution in a less obtrusive Capacity Range style These indoor units can be used in 11 heat pump
15 - 16 SEER and multi-zone systems providing more options to your customers Install SLZs in a hard ceiling (with a access panel for
bull 96 HSPF
servicing) or in a 2x2 extra space drop ceiling With a built-in drainshylift mechanism for condensate removal and a 4 ventilation-air intake knockout option and multiple options for the 11 systems the SLZ
~ ~ handles a variety of installation needs
Two of the three 11 systems are ENERGY STAR qualified
Vl l
OQ
(I) I
N o l (I)
Vl ltV (I)
3 Vl r o ~ n OJ V (I)
1shy(MS-A12WA MODEL SHOWN)
MS COOLING-ONLY
IJON-INVERTER
Model Name Indoor Unit
Outdoor Unit
MS-A09WA MS-A12WA
MU-A09WA MU-A12WA
Cooling 1
Rated Capacity Btuh 9500 12000
Capacity Range Btuh
Total Input W 870 1070
Energy Efficiency SEER 13
Moisture Removal Pintsh 27 32 Sensible Heat Factor 068 070
Power Supply Phase Cycle Voltage 1 Phase 60Hz 115V 2
Voltage Indoor - Outdoor L1-N AC 115V Indoor - Outdoor N-2 AC 115V Indoor - Remote Controller Wireless Type
Indoor Unit
MCA A 12
Fan Motor FLA 095
Airilow (Lo-Med-Hi Poweriul)
DRY (CFM) 183-261-335-367 222-286-406-446
WET (CFM) 162-233-300-328 198-254-363-399
Sound Pressure Level (Lo-Med-Hi)
dB(A) 26-32-40-42 33-38-45
External Finish Color Munsell No 1OY 9202
Dimension Unit
W In 30-1116
0 In 8-14
H In 11-34
Weight Unit Lbs 23
Field Drainpipe Size 00 In 58
Outdoor Unit
MCA A 14 16
MOCP (Time Delay) A 15 20
Fan Motor FLA 063 093
Compressor
Model (Type) Single Rotary
RLA 93 1082
LRA 47 56
Airilow CFM 1083 1327
Refrigerant Control Capillary Tube
Sound Pressure Level (Cooling) 1
dB(A) 47 52
External Finish Color Munsell No 3Y 7811
Dimensions
W In 31-12 33-716
0 In 11-14 11-716
H In 21-58 23-1316
Weight Lbs 78 96
Remote Controller Type Wireless Remote
Refrigerant
Type R410A Charge Lbs Oz 25 31
Oil Type (FI Oz) NE022 (108)
Refrigerant Pipe
Gas Side 00 In 38 12
Liquid Side 00 14
Height Difference (Max) Ft 35
Length (Max) 65
Connection Method IndoorOutdoor FlaredFlared
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling) - Indoor DB 800 F(270 e) WB 670 F(190 e) Outdoor DB 950 F(350 e) WB 750 F(240 e) 2 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice
LlIVIITED WARRANTY ISeven-year warranty on compressor Five-year warranty on parts
10 MITSUBISHI ELECTRIC
I
R ---I Vl
J(MSY-GE1 7NA MODEL SHOWN) OQ
MSY COOLI NG-ON LY (CO NT ) CD N o J CD
s Vl OJ J
Cooling 1 0shy
s Vl -lt Vl
~~~~~-=~------~~--------------------------~~~~----------------------------~ jVoltage
205-272-335shy145-170-237 -321-399
420-533 170-237 -300shy
385-498
26-32-38-44-49Indoor Unit
Outdoor Unit
194-240-304shy385-498
28-33-38-44-49
388-469-628-738
347-420-562-661
34-41-49-53
CD n 3-i n OJ 0389-639-848 o J350-576-763 V)
32-42-49
2 9 43Refrigerant
FV50S (040) NE022 (295)
Refrigerant Pipe
Refrigerant Pipe Length
Connection IndoorOutdoor FlaredFlared
Method
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling) - Indoor DB 80deg F(27deg e) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice
LIMITED WARRANTY ISeven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 11
~ (MSZ-FE12NA MODEL SHOWN)
MSZ HEAT PUMP TAX
CREDIT
Model Name
Cooling 1
Indoor Unit Outdoor Unit
Rated Capacity Btuh
MSZ-GE09NA MUZ-GE09NA
9000
MSZ-FE09NA HshyMUZ-FE09NA bull
9000
MSZ-GE12NA MUZ-GE12NA
12000
MSZ-FE12NA MUZ-FE12NA
12000
H-bull MSZ-G MUZ-G
14000
Capacity Range Btuh 3800-12200 2800-9000 3800-13600 2800-12000 3100-18200
Total Input W 660 (205-1200) 580 (160-650) 960 (205-1300) 930 (160-960) 1080 (160-2000)
Energy Efficiency SEER 21 26 205 23 21
Moisture Removal Pintsh 15 21 25 29 27
Sensible Heat Factor 082 076 074 073 080
Heating at 47deg F 2
Rated Capacity Btuh 10900 10900 14400 13600 18000
Capacity Range Btuh 4500-14100 3000-18000 5500-18100 3000-21000 4800-20900
Total Input W 760 (255-1200) 710 (150-2250) 1170 (340-1660) 950 (150-2250) 1600 (270-2010) HSPF (IV) BtuhlW 10 106 10
Heating at 17deg F3 Rated Capacity Btuh 6600 6700 8800 8300 11300 Rated Total Input W 700 650 900 800 1150 Maximum Capacity Btuh 8700 12500 11200 13600 15900
Heating at 5deg F Maximum Capacity Btuh 7061 10900 9194 12500 13022
Power Supply Phase Cycle Voltage 1-phase 60Hz 208 230V 4
Voltage
Indoor - Outdoor S1 - S2 AC 208 230V
Indoor - Outdoor S2 - S3 DC12-24V
Indoor - Remote Controller Wireless Type (Optional Wired Controller DC 12V)
Indoor Unit
MCA A 10
Fan Motor FLA 076
Airflow at Cooling (Lo-Med-Hi-Super HI-Powerful) 1
DRY (CFM) 145-170-237-321-399 162-226-339-381 145-170-237-321-399 162-226-381-410 205-272-335-420-533
WET (CFM) 109-134-201-286-364 144-202-307-343 109-134-201-286-364 144-202-350-367 170-237-300-385-498
Airflow at Heating (Lo-Med-Hi-Super HI-Powerful) 2
WET (CFM) 145-170-237-321-406 166-240-367-381 145-170-237-321-406 166-240-399-420 205-247 -304-367-463
Sound Pressure Level at Cooling (Lo-Med-Hi-Super HI-Powerful) 1
dB(A) 19-22-30-37-43 22-31-39-42 19-22-30-37-45 22-33-43-45 26-32-38-44-49
Sound Pressure Level at Heating (Lo-Med-Hi-Super HI-Powerful) 2
dB(A) 19-22-30-37-43 22-31-40-42 19-22-30-37-43 22-33-43-44 26-30-35-40-46
External Finish Color Munsell No 10Y 92 I 02
Dimension Unit
Wln 31-716 31-38 31-716 31-38 31-716
0 In 9-118 10-18 9-18 10-18 9-18
H In 11-58
Weight Unit Lbs 22 27 22 27 22
Field Drainpipe Size 00 In 58
Outdoor Unit
MCA A 12
MOCP A 15
Fan Motor FLA 050 056 050 056 050
Compressor
lVIodel (Type) DC INVERTER-driven DC INVERTER-driven Twin
Rotary DC INVERTER-driven DC IIWERTER-driven Twin Rotary
RLA 66 86 66 86 74
LRA 82 108 82 108 93
Airflow (CoolingHeating) CFM 11511225 1102 11187 12291172 1102 11187 12431229 Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(A) 46 48 49 48 49
Sound Pressure Level at Heating 2 dB(A) 50 49 51 49 51
External Finish Color Munsell No 3Y 78 11
Dimensions
Wln 31-12
0 In 11-114
H In 21-58
Weight Lbs 66 80 77 80
Remote Controller Type Wireless Remote (Optional Wired Controller)
Refrigerant
Type R410A
Charge Lbs Oz 112 29
Oil Type (fl oz) NE022 (108) NE022 (152)
Refrigerant Pipe Gas Side 00 In 38 12
Liquid Side 00 In 14 14
Refrigerant Pipe Length Height Difference (Max) Ft 40
Length (Max) Ft 65 I
Connection Method IndoorOutdoor FlaredFlared
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg e) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg e) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg e) Outdoor DB 47deg F(8deg e) WB 43deg F(6deg e) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg e) Outdoor DB 17deg F(-8deg e) WB 15deg F(-9deg e) 4 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice
12 +MITSUBISHI ELECTRIC LIMITED WARRANTY ISeven-year warranty on compressor Five-year warranty on parts
- shy(MSY(Z)-D30NA MODEL SHOWN)
Vl J
09 (I)
I
N o J (I)
s Vl N Vl
-0 (I) n 31 n OJ 0 o J V)
Model Name Indoor Unit MSZ-GE18NA MSZ-FE18N MSZ-GE24NA MSZ-D30NA MSZ-D36NA
Outdoor Unit MUZ-GE18NA MUZ-FE18rK MUZ-GE24NA MUZ-D30NA MUZ-D36NA Rated Capacity Btuh 17200 18000 22500 30700 33200
Capacity Range Btuh 3700-18700 8200-25200 8200-31400 9800-30700 9800-33200
Total Input W 1640 (240-2070) 1270 (570-2280) 1800 (570- 3580) 3850 (620-3850) 4360 (620-4360) Cooling 1
Energy Efficiency SEER 192 202 190 145
Moisture Removal Pintsh 46 27 27 99 11 3
Sensible Heat Factor 071 084 075 064 062
Rated Capacity Btuh 21600 21600 27600 32600 35200
Capacity Range Btuh 3500-25200 7500-29700 7500-36900 8700-34000 8700-36000 Heating at 47deg F 2
Total Input W 1900 (230-2680) 1540 (520-2240) 2340 (520- 3650) 3360 (520-3600) 3840 (520-4100)
HSPF (Region IV) BtuhIW 10 103 10 82
Rated Capacity Btuh 13400 11700 16000 19500 21800
Heating at 17deg F 3 Total Input W 1450 2180 3290 2400 2820
Maximum Capacity Btuh 17200 19300 24600 20800 22800 Heating at 5deg F
Maximum Capacity Btuh 13562 21 600 21160 16305 19090
Power Supply Phase Cycle Voltage 1 Phase 60Hz 208230V 4
Indoor - Outdoor S1-S2 AC 208 230V Voltage Indoor - Outdoor S2-S3 DC12-24
Indoor - Remote Controller Wireless Type (Optional Wired Controller DC12V) MCA A 10 Fan Motor FLA 076
DRY (CFM) 230-275-339-420-533 388-469-628-738 388-469-628-738 389-639-848 Airilow (Cool) (Lo-Med-Hi-Super HI-Poweriul) 1
WET (CFM) 194-240-304-385-498 347-420-562-661 347-420-562-661 350-576-763
Airilow (Heat) (Lo-Med-Hi-Super HI-Poweriul) 2 DRY (CFM) 230-275-339-431-512 388-469-628-738 388-469-628-738 445-639-848
Sound Pressure Level (Cooling) (Lo-Med-Hi-Super 28-33-38-44-49 34-41-49-53 34-41-49-53 32-42-49
HI-Poweriul) 1
Sound Pressure Level (Heating) (Lo-Med-Hi-Super dB(A)
Indoor Unit 28-33-38-43-48 32-41-49-52 32-41-49-52 34-42-49-49HI-Poweriul) 2
External Finish Color Munsell No 1 OY 9202
W In 31-716 43-516 46-116
Dimension Unit D In 9-18 9-38 11-58
H In 11-5 8 12-1316 14-38
Weight Unit Lbs 22 37 40
Field Drainpipe Size OD In 58
MCA A 14 171 21
MOCP A 15 20 25
Fan Motor FLA 093
Model (Type) DC INVERTER-driven Twin Rotary
Compressor RLA 100 129 16
LRA 125 161 20
Airilow CFM 1730 1659 17691 701 1941
Outdoor Unit Refrigerant Control Linear Ex~ansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(A) 54 55 56
Sound Pressure Level at Heating 2 dB(A) 56 55 57
External Finish Color Munsell No 3Y 7811
W In 33-116
Dimensions D In 13
H In 33-716 34-58 33-716
Weight Lbs 119 141
Remote Controller Type Wireless Remote (Optional Wired Controller)
Type R410A
Refrigerant Charge Lbs Oz 3 7 43 410
Oil Type (FI Oz) NE022 (152) FV50S (135) NE022 (29)
Gas Side OD 12 58In
Refrigerant Pipe Liquid Side OD 14 38
Height Difference (Max) 50
Length (Max) Ft
100 I Connection
Mpthon IndoorOutdoor Flared Flared
NOTESTest conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg C) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F (24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F(6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 17deg F(-8deg C) WB 15deg F(-9deg C) 4 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice LIMITED WARRANTY ISeven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 13
(SEZ-KD12NA MODEL SHOWN)
SEZ HEAT PUMP TAX
CREDIT
Model Name Indoor Unit SEZ-KD09NA4 SEZ-KD12NA4 SEZ-KD15NA4 SEZ-KD18NA4
Outdoor Unit SUZ-KA09NA SUZ-KA12NA SUZ-KA15NA SUZ-KA18NA Rated Capacity Btuh 8100 11500 14100 17200
Capacity Range Btuh 3800-10900 3800-13300 3800-17000 3800-19000
Cooling 1 Total Input W 670 920 1170 1380
Energy Efficiency SEER 15 16 155 175 Moisture Removal Pintsh 15 24 26 34 Sensible Heat Factor 080 076 080 079
Rated Capacity Btuh 10900 13600 18000 21600
Heating at 4YO F 2 Capacity Range Btuh 4800-14100 4800-16400 4800-21100 4800-24900
Total Input W 1020 1140 1500 1700 HSPF(lV) BtuhIW 100 Rated Capacity Btuh 6700 9000 11900 13100
Heating at 1 yo F 3 Rated Total Input W 810 920 1200 1350 Maximum Capacity Btuh 7300 9800 13700 15000
Power Supply Phase Cycle Voltage 1 Phase 60Hz 208 230V 4 Indoor - Outdoor S1 - S2 AC 208-230V
Voltage Indoor - Outdoor S2 - S3 DC 12-24V Indoor - Remote Controller See optional accessories chart (pg 26 and 27) MCA A 1 Fan Motor FLA 051 057 074
Airflow (Lo-Med-Hi) DRY (CFM) 194-247-317 247-317-388 353-441-529 423-529-635
WET (CFM) 174-222-285 222-285-349 317 -396-4 76 381-476-572 External Static Pressure 3 In wG 002-006-014-020 Sound Pressure Level dB(A) 23-26-30 23-28-33 30-34-37 30-34-38
Indoor Unit External Finish Galvanized-Steel Sheets
W In 31-18 39 46-78
Dimension Unit D In 27-916
H In 7-78
Weight Unit Lbs 42 50 54 62 Field Drainpipe Size 00 In 1-14
MCA A 12 14
MOCP A 15 Fan Motor FLA 050 093
Model DC Inverter DC Inverter Twin Rotary
I (Type)Compressor
RLA 66 74 10
LRA 82 93 125
Airflow (CoolingHeating) CFM 11511225 12291172 1 2431 229 17301659
Outdoor Unit Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(A) 46 49 54 Sound Pressure Level at Heating 2 dB(A) 50 51 56
External Finish Color Munsell No 3Y 7811
W In 31-12 33-16
Dimensions D In 11-14 13
H In 21-58 33-716
Weight Lbs 66 77 80 119 Remote Controller Type See optional accessories chart (pg 26 and 27)
Type R410A
Refrigerant Charge Lbs Oz 116 2 9
Type (fl Oil
oz) NE022 (108)
Refrigerant Pipe Gas Side OD In 38 Liquid Side 00 In 14
Refrigerant Pipe Height Difference (Max) Ft 40 Length Length (Max) Ft 65
Connection IndoorOutdoor FlaredFlared
Method
316
NE022 (152)
12
50
100
I
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg C) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F(8deg C) WB 43deg F(6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 17deg F(-8deg C) WB 15deg F(-9deg C) 4 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
14 MITSUBISHI ELECTRIC
SEZ STATIC PERFORMANCE CURVES (SEZ-KD12NA4 MODEL SHOWN)
SEZ-KD09NA4 SEZ-KD09NA4 (External static pressure O06[inwG]) 208230V 60Hz
[020] V L
5 [016
~l [0 12
]
SEZ-KD09NA4
~ ltij
~ [008
Jj
]
]
[004J ~
V V Middle
Low
V
19h
Rated point
1
o [141] [176J 1212) )247] [282J [318]
Airll ow rat e [CFM)
SEZ-KD12NA4 (External static pressure O06[inwG]) 208230V 60Hz
[020
5 [016
]
]
[353J
Limit
]
~ V
~ [ [0 12
u ltijJ[008
[004
]
_V ]~ Low
V
k-iddle
Rated POint
o [212) [247] [2 82] [318] [353] [388]
Airtlow rate [C FM]
SEZ-KD1SNA4 (External static pressure O06[inwGl) 208230V 60Hz
[424)
1020]
5 [016
~ ~ [012
~ ltij
~ [008
Jj
J
)
]
[004 ]
o
VV V [ Low
VV
vV High
Middle
I Rated point
[282] [318) [353] [388] [424] [459] [494] [530] [565J
Airllow rat e [CFM]
SEZ-KD18NA4 (External static pressure O06[inwG]) 208230V 60Hz
50 10 20]
] 40
5 [016
s 30 [ (012 )
ltij 20 ~ [008 )~Jj
10 [004]
V
Low
v Limit
rIV High
V [ Middle
~
1
Rated point
f318) [353) [388] [424] [459] [494] [530] [565] [600] [636] [671 )
Airllow rate [CFM]
(External static pressure O14[inwG]) 208230V 60Hz 80
[0 32
70 [028
5 60 [024
20 [0 08
10 [004
]
]
J
]
]
J
]V
]
U~it
V
k
High
~V Rated POI~1 V Middle Low
~
o [141] [1 76] 12121 )247J [282] [318]
Airtlow rate [CFM)
SEZ-KD12NA4 (External stat ic pressure O14[inwG]) 208230V 60Hz
[032]
[028J
5
[353]
J
~ [024
-~ [020] V-is
J V Il Hi9h Rated point
[016
~ ]
V V1 Middle
~ [012
[008]~
[004)
o [212)
[247)
SEZ-KD1SNA4
Low r
[282] [31 8) [353]
Airllow rale [CFM]
[388]
(External static pressure O14(inwG]) 208230V 60Hz
[032J
[424
]
2 V[028
5 [024]
V-i
] V High i [020
] K
Middle Rated point [0 16
g ]
~ -
QJj [0 12
J Low
[008
] I
~
[004
o [282J [318) [353J [388J [424) [459] [4 94] [530) [565)
Airt low rate [CFM]
SEZ-KD18NA4 (External statiC pressure O14(inwG]) 208230V 60Hz
1032
1028
~ 1024
-~ [0 20
is (0 16 ltij E ~ [012
(008
(004
o
I
]
]
)
]
)vlt ]
]
~ V
VV
Low
Limit
V
Ji9h
Middle l
Rated point
1 t
1
~ [318] [353] [388] [424] [459) [4 94] [530) [565) [600] [636] [671)
Airllow rate [CFM]
(External static pressure O20(inwG]) 208230V 60Hz
[032 ]
[028 J
5 [024
~ [020
is [016
1 [012Jj
[008
[004
J
]
]
] )
]
V Low
umz V High
~V
Rated point
Middle
1
[141] [176] [212) [247) [282) [318) [353J
Airtlow rat e [CFM]
SEZ-KD12NA4 (External static pressure O20(inwG]) 208230V 60H z
[032 ] LLimit
)
[0 28
5 ]
V
[024 -~ [020] V Rated point
Highis ~
) V
bull Middle
]~V I
[016
~ ~ [012
] Low
[008
]
[0 04
o [212) [247] [282] [318] [353] [388] [424]
Airllow rate [CFM]
SEZ-KD1SNA4 (External static pressure O20(inwG]) 208230V 60Hz
80 [032 ]
70 [0 28
~ [ O~~ -
ltij
E 30 ~ [0 12
20 [008
10 [004
o
)
J
]
]
JV
J
J
Limit V
LV High
V ~
K Rated point
Middle
VV 1gt
Low
I-
~ [282) [318) (353] (388) (424) 1459] [494] 15301 [565)
Airtlow rate [CFM]
SEZ-KD18NA4 (External static pressure O20[inwG]) 208230V 60Hz
[032
[028
~ [024sect
I [020
~ [016
~ Jj [0 12
[008
[004
o
]
)
]
]
]
~ )
]
]
1V
V 1
V
Low
1 limit
~~~ I ~~ High
~ R~ted pOini
Middle
1 1 -
[31 8) [353] [388] [424) [459] [494] [530] (565) [600] (636) [671J
Airllow rate [CFM)
Vl ~ ca (I)
I
N o ~ (I)
Vl m N Vl
-0 (I) n 3-i n QJ ~ o ~ tn
Note ESP 20S230V 60 Hz See manual for Static Performance Curve including 002 in WG
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts ~MITSUBISH[ ELECTRIC 15
SLZ HEAT PUMP (SLZ-KA12NA MODEL SHOWN)
Model Name Indoor Unit SLZ-KA09NA SLZ-KA12NA SLZ-KA15NA
Outdoor Unit SUZ-KA09NA SUZ-KA12NA SUZ-KA15NA Rated Capacity Btuh 8400 11100 15000
Capacity Range Btuh 3100-10900 3100-13300 3100-22200
Cooling 1 Total Input W 700 920 1460
Energy Efficiency SEER 15 154 16 Moisture Removal Pintsh 12 23 45 Sensible Heat Factor 080 076 080
Rated Capacity Btuh 10900 13 600 18000
Heating at 4r F 2 Capacity Range Btuh 3100-14100 3100-17100 3100-17100 Total Input W 930 1180 1950 HSPF (IV) BtuhIW 96 Rated Capacity Btuh 6200 8300 10200
Heating at 17deg F 3 Rated Total Input W 740 930 1310 Maximum Capacity Btuh 8300 10200 12000
Power Supply Phase Cycle Voltage 1 Phase 60Hz 208 230V 4 Indoor - Outdoor S1 - S2 AC 208-230V
Voltage Indoor - Outdoor S2 - S3 DC 12-24V
Indoor - Remote Controller See optional accessories chart (pg 26 and 27) MCA A 1 Fan Motor FLA 023 028 028
Airflow (Lo-Med-Hi) DRY (CFM) 280-320-350 280-320-390 280-320-390
WET (CFM) 250-290-320 250-290-350 250-290-350
Sound Pressure Level dB(Al 29-32-38 30-34-39 31-35-40
Indoor Unit External Finish Galvanized-Steel Sheets Grille Munsell 64Y 8904
W In 22-7 16 (25-58)
Dimension Unit (Grille) D In 22-716 (25-58
H In 8-316 (1316)
Weight Unit (Grille) Lbs 36 (7) Field Drainpipe Size 0 0 In 1-14 MCA A 12 MOCP A 15 Fan Motor FLA 050
Model (Type) DC INVERTER-driven DC INVERTER-driven
Compressor RLA 66
LRA 82
Airflow (CoolingHeating) CFM 11511225 1 229 1 172
Outdoor Unit Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(AJ 46 49 Sound Pressure Level at Heating 2 dB(AJ 50 51
External Finish Color Munsell No 3Y 781 1
W In 31 shy12
Dimensions 0 In 11-14
H In 21-58
Weight Lbs 66 77
~e R410A
Refrigerant Charge Lbs Oz 1 16
Oil Type (fl oz) NE022 108)
Refrigerant Pipe Gas Side 0 0 In 38 Liquid Side 00 In 14
Height Difference (Max) Ft 40 Refrigerant Pipe Length
Length (Max) Ft 65
Connection Method IndoorOutdoor FlaredFlared
29
Twin Rotary 74
93
12431 229
80
NE022 l152) 12
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg C) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F(8deg C) WB 43deg F(6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 17deg F(-8deg C) WB 15deg F(-9deg C) 4 Indoor units receive power from outdoor units through field-supplied interconnectedwiring Specifications are subject to change without notice
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
16 MITSUBISHI ELECTRIC
MHK1 WIRELESS REMOTE CONTROLLER KIT Exclusive for INVERTER-driven Mr Slimreg Systems VlWireless Technology a J
JMITSUBISHI ELECTRIC
Wireless Receiver
MHK1 Kit includes
09 mMRCH1 WIRELESS REMOTE CONTROLLER I Nbull Backlit easy-to-read display o
bull Dual setpoint control with system changeover J m
bull Enabled with RedLlNKTM reliability
bull Compatible with MCCH1 Vl Portable Central Controller m
N bull Installs Anywhere Vl
MFH1 WIRELESS RECEIVER N Vlbull Required for MRCH1 Wireless
CRemote Controller m bull Enabled with RedLiNK reliability n
31 n OJ o J en
SEZ and SLZ 11 systems with SUZ outdoor unit
Function Description
ONOFF OnOff operation for a single indoor unit
Operation Mode Cool I Drying I Auto I Heat I Fan only Available operation modes dependant on connected system
Temperature Setting Set temperature from 50degF - 8rF depending on operation mode and connected system
System Changeover Deadband Value 2-8degF
Schedule Operation 5-25-1-1
Fan Speed Setting HiMid-2Mid-1 IlowlAuto Available fan speed settings dependant on connected system
Air Flow Direction Setting Air flow angles 100deg - 80deg - 60deg - 40deg and oscilate Available air flow direction settings dependant on connected system
PermitProhibit Function Individual prohibit operations for each remote controller function (ONI OFF Set Temperature and Operation Mode)
Space Temperature Displays the measured space temperature
Error Indication Displays error code
Display Outside Temperature and Humidity
Requires optional MOS1 Outside Air Sensor
Dimensions - ryv x D x H) Remote Controller 5-316 x 1-12 x 3-916 Receiver 3-14 x 1-516 x 6-716
Operating Ambient Temperature Remote Controller 32 - 120degF Receiver -40 - 165degF
Operating Ambient Humidity Remote Controller 5 - 90 RH (non-condensing) Receiver 5 - 90 RH (non-condensing)
Power Supply 2 AA batteries
MRCH1 MIFH1 MRC1
Wireless Wall-Mounted Remote Controllers Wireless Receiver Cable
Accessories MCCH1 MOS1
Portable Central Controllers Outside Air Sensor
MITSUBISHI ELECTRIC 17
MULTIPLE ROOMS WITH INDIVIDUAL CONTROL FROM A SINGLE SYSTEM Enjoy ideal levels of comfort in the rooms you use most with our multi-room system Each room (zone) operates independently People in different rooms - the kitchen master bedroom or living room - can enjoy temperature settings that make each of them most comfortable
If you re looking for a complete comfort solution for several different rooms the MXZ multi-room system is the right choice The system is flexible enough to conform to a particular cooling and heating need and offers numerous different indoor unit combinations In addition up to eight indoor units can be connected to one outdoor unit Now with a SEZ horizontal ducted unit and a MFZ floorshystanding unit homeowners can enjoy an even greater range of zoning options provided by an MXZ system
An MXZ multi-room system is an excellent choice for supplementing capacity to a current system conditioning newly furnished spaces or new additions and replacing a system within a home Homeowners can also benefit from lower energy costs year-round while staying comfortable thanks to Mitsubishi Electrics energy-efficient technologies that are a part of every system that we make
To add to the level of energy efficiency the MXZ -2B20NA and MXZ -3B24NA systems qualify for both ENERGY STARreg and the federal tax credit (See details on page 21 for applicable indoor unit combinations)
At right a single level home with several system types represented (For illustrative purposes only)
MFZ Floor-Standing Indoor Units for MXZ Heat Pump Systems
Floor-standing indoor unit mounts three inches above the floor and has front panel access to the filter for ease of cleaning
The MFZ units provide energy-efficient solutions to provide personalized comfort for difficult areas that may be smaller or dont have usable space on the walls
MFZ units on MXZ systems include the following features bull Top and bottom discharge vanes bull Hot-start technology bull Quiet operation bull Wireless remote control (optional wall-mounted controller)
18 MITSUBISHI ELECTRIC
MSZ Wall-Mounted Indoor Units for MXZ Heat Pump Systems
Providing a wide range of cooling and heating capacities each wall-mounted indoor unit mounts high on a wall and connects to a branch box or the outdoor unit by a refrigerant line run via a 3 hole The MSZ units provide highly efficient solutions to cooling and heating needs and provide personalized comfort for the individual zones in which they are installed
MSZ units on MXZ systems include the following features bull Sleek flat panel design bull Hot-start technology bull Quiet operation bull i-seeM sensor technology (MSZ-FE0912NA models only) bull Enhanced filtration system (MSZ-FE0912NA models only) bull Wireless remote control (optional wired wall-mounted controller)
SLZ Ceiling-Recessed Indoor Units for MXZ Heat Pump Systems
The new SLZ-KA ceiling casette systems offer a wide air-flow pattern for better air distribution
offered to your customers Installation can be done in a hard ceiling (with a access panel for servicing) or placed into a 2x2 drop ceiling With a built-in drain lift mechanism for condensate
removal and a 4 ventilation air intake knockout option the SLZ is ready to handle a variety of installation needs
SLZ units on MXZ systems include the following features bull Wide air-flow pattern for better air distibution bull 4 ventillation air intake knockout bull Built-in condensate lift mechanism bull Wireless RedLlNKTM remote controller
SEZ Horizontal Ducted Indoor Units for MXZ Heat Pump Systems
SEZ ducted units can provide split air-conditioning system advantages with the added benefit of being concealed to provide virtually no visual footprint within the conditioned space other than a register and grille for the air to flow With the use of short run ductwork these units can provide comfort to a single room that needs air dispersed evenly throughout the space unusually shaped rooms and adjacent rooms
The SEZ unit on MXZ systems include the fOllvowin fatures _
g~e~~~~==Zl[bull Concealed design for short-run ductwork bull Quiet operation bull Built-in condensate lift mechanism
JMITSUBISHI ELECTRIC 19
s c t
I
N o J ro o ltro ~ ro ~
DIAMOND COMFORT MXZ MULTI-ZONE SYSTEMS MXZ-B Series multi-zone systems provide personalized comfort control and energy efficiency in up to eight rooms with only a single outdoor unit The MXZ-B Series system features include
bull Individual zone control bull Mix and match flexibility of indoor unit styles and combinations bull A wide range of indoor unit capacities that match the room size and requirements bull Flexible design options to tackle the most challenging multi-room installations bull Efficient systems including three systems [mxz series] that meet energy starltID and
federal tax credit requirements bull Simple quick and cost-effective installation keeps install costs down on new construction
and disruption to a minimum on renovations and refits
Efficiency and performance ratings depend on the number style and capacity of the indoor units installed with each Multi-Zone System
MXZ -2 B20 NA - 1 (2 1 ) MXZ -3 B24 NA (2 13 1) Ou tdoo r Unit Outdoor Uni t
MSZ-GE09NA Indoor Units
SEZ-KD12NA Indoor Unit
MSZ- GE06NA
~~~~li
(At least two indoor units MSZ-GE06NAIndoor Unit must be installed) Indoor Unit
(Two indoor units must be installed )
MXZ -3 B30 NA (2 1 3 1) Outdoor Unit
SEZ-KD12NA Indoor Unit
~~~i
(At least two indoor units MSZ-GE06NA must be installed)
Indoor Unit ~
MFZ- KD12NA Indoor Unit
MXZ-8B48NA (2 1-8 1) Outdoor Unit
(At least two indoor units
must be installed)
(At least two indoor units must be installed)
MFZ-KD09NA Indoor Units
MSZ-GE09NA Indoor Units
SEZ-KD12NA Indoor Unit
MSZ INDOOR UNIT
MSZ-FE18NA
PEAD HORIZONTAL -DUCTED INDOOR UNIT
PEAD-A24AA
MSZ INDOOR UNIT SEZ HORIZONTAL-DUCTED MSZ-FE18NA
INDOOR UNIT MFZ FLOOR-STANDING SEZ-KD18NA INDOOR UNIT
MFZ-KA12NA
20 AMITSUBISHI ELECTRIC
MULTI-ROOM MXZ-8 INVERTER HEAT PUMP R
Model Name Outdoor Unit MXZ-2B20NA-1 5 MXZ-3B24NA 6 MXZ-3B30NA MXZ-4B36NA 7
Indoor Unit
Cooling 1 Non-ductedl Ducted
Rated Capacity Btuh 1800020000 2200023600 28400127400 3540034400
Capacity Range Btuh 7800-20000 12600-25500 12600-28400 12600-36400
Total Input W 2190 (630-219QL 2460 (1000-2950) 3330 l1 000-3330) 3 940 (1 000-4020)
Heating at 4JO F 2 Non-ductedl Ducted
Rated Capacity Btuh 2200022000 2500024600 2860027600 3600034400
Capacity Range Btuh 8500-25500 11400-30600 11 400-36000 11400-43000
Total Input W 2620 (520-2620) 1900 (740-2600) 2220 (740-2820) 3100 (740-3940)
Heating at 1JO F 3 Non-ductedl Ducted
Rated Capacity Btuh 1250012500 1400014000 1600015100 2220020300
Rated Total Input W 13501430 13801570 21202 140 24302340
Maximum Capacity Btu h 1450014500 1880017000 1880018000 2460025400
Maximum Total Inl2ut W 15001590 21202230 21202140 33403450
Power Supply Phase Cycle Voltage 1-phase 60Hz 2081 230V 8
Voltage Indoor shy Outdoor S1 - S2 AC 2081 230V
Indoor shy Outdoor S2 - S3 DC12-24V
Outdoor Unit 4
MCA A 15 19
MOCP A 20
Fan Motor FLA 096 093
Compressor
Model (Type)
DC INVERTER-driven Twin Rotary
RLA 101 11 144
LRA 15
Airflow (CoolingHeating) CFM 14851 640 20681605 13651605 20682068
Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1
dB(A) 49 54 49 54
Sound Pressure Level at Heating 2
dB(A) 51 49 57
External Finish Color Munsell No 30Y 781 1
Dimensions
W In 33-116 35-716
D In 13 12-58
H In 27-1516 35-7116
Weight Lbs 130 150 153
Indoor Unit No of Units 2 23 23 234
Remote Controller Type Associated with the Indoor Unit
Refrigerant
Type R410A
Charge Lbs Oz 515 7 11 813
Oil Type (fl oz)
NE022 (237) NE022 (294)
Refrigerant Pipe Gas Side 00 In AB 38 A 12 BC 38 A 12 BCD 38
Liquid Side 00 In 14
Refrigerant Pipe Length Height Difference (Max) Ft 4933 9
Length (Max) Ft 164 (A+B) 230 (A+B+C) 230 (A+B+C+D)
Connection Method IndoorOutdoor FlaredlFlared
Compatible with the MSZ-A MSZ-GA MSZ-FD MSZ-FE MSZ-GE MFZ-KA and SEZ-KD series indoor units (PLA-18 amp PCA-24 on the MXZ-MXZ-3B PLA-24 amp PCA-24 on the MXZ-4B)
NOTES Test conditions are based on AHRI 210240 One indoor unit is turned off during low-speed testing under the new test conditions Systems actually exhibit higher energy efficiencies during normal operation
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F (35deg C) WB 75deg F (24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F (6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 600 F (160 C) Outdoor DB 17deg F (_80 C) WB 150 F (_90 C) 4 Refer to pages 12 and 13 for Indoor Unit specifications 5 Data from combination of two Indoor Units 9000 Btuh (non-ducted) or one 9000 Btuh and one 12000 Btuh (ducted) 6 Data from combination of two Indoor Units 6000 Btuh and one 9000 Btuh (non-ducted) or three 9000 Btuh (ducted) 7 Data from combination of four Indoor Units 9000 Btuh (non-ducted and ducted) 8 Indoor units receive power from outdoor units through field-supplied interconnected wiring 9 49 Applies to installations where the outdoor unit is installed below the indoor unit
Power factor equals 97 percent
Specifications are subject to change without notice
MULTI-ZONE ENERGY STAR AND TAX CREDIT SYSTEMS
Model Indoor Unit Combinations SEER HSPF
MXZ-2B20NA-1 2 x MSZ- GE09NA 18 8 9
MXZ- 3B24NA 2 x MSZ- GE06NA 1 x MSZshy GE09NA
17 5 9 3
MXZ- 3B24NA 2 x MSZ-GE06NA 1 x MSZ- GE12NA
17 5 93
For more details on all ENERGY STAR and tax credit systems go to wwwmitsubishicomfortcomtaxcredit
See page 25 for additional info on efficiency
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 21
MXZ-8B48NA THE ULTIMATE ZONING SOLUTION
The Mitsubishi Electric MXZ-S84SNA eight-zone unit As a member of the expanding MXZ-B Series of multi-zone systems the MXZ-8B outdoor unit incorporates branch boxes to connect up to eight indoor units MXZ- 8 B48 NA (2 1 - 8 1 )
Outd oor Uni t The INVERTER-driven compressor at the heart of the MXZ-8B -~-- shy
outdoor unit provides variable capacity control allowing the system to adjust to the specific demands of the interior space ~ as needed not the hard start and stop of a traditional system I[iDA Jinstalled in most US homes
The MXZ -8B48NA has only one port on the outdoor unit for two insulated refrigerant lines which run into the home or business to connect to a branch box or boxes From the branch box(es) gas and liquid refrigerant piping run to each of the indoor units The LEV in the branch box(es) controls the refrigerant flow as the load of each zone changes
Through the branch box(es) (the PAC-AKA31 BC three-port andor the PAC-AKA51 BC five-port) the system can connect from two indoor units up to eight indoor units depending on application requirements
The flexibility of the system doesnt stop there The MXZ-8B48NA has rated capacities of 48000 Btuh for cooling and 54000 Btuh for heating System operation however can range from a minimum 12000 Btuh to a maximum 54000 Btuh in cooling and a maximum of 60000 Btuh in heating This type of performance supports a large variety of applications
The MXZ-8B48NA allows for further flexibility because it supports a connected indoor unit capacity from 22 to 130 or 12000 Btuh to a maximum 70200 Btuh depending on diversity
Connectable Indoor Units General Features bull Four-ton outdoor unit can support up to
eight indoor units using branch boxes bull Wide variety of indoor unit styles
-=--_-=-----= - - J _ 1
including wall-mounted floor-standing MSZ-FE09 12 18NA MSZ-GE06 09 12 15 18 24NA ceiling-cassette ducted
bull Individual control up to eight (8) zones using wired or wireless controls
bull Advanced microprocessor control bull Auto restart following a power outage bull Self-check function offering SEZ-KD09 1215 18NA PEAD-A24AA
integrated diagnostics ~--- Jbull Limited warranty five years on parts and
defects and seven years on compressors
SLZ-KA09 1215NA MFZ-KA09 12 18NA
22 MITSUBISHI ELECTRIC LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
I
RMULTI-ROOM MXZ-8 INVERTER HEAT PUMP
Model Name Outdoor Unit MXZ-BB4BNA Cooling 1 Rated Capacity
Non-ducted Rated Total Input Ducted
Maximum Capacity
Rated CapacityHeating at
Rated Total InputIndoor Unit 4JO F 2 Non-
ductedDucted Maximum Capacity
Rated Capacity Heating at
Rated Total InputlJO F 3 Non-ductedDucted Maximum Capacity
Power Supply Phase Cycle Voltage
Indoor - Outdoor Sl - S2 Voltage
Indoor - Outdoor S2 - S3
MCA
Recommended FuseBreaker Size
Fan Motor
Compressor
Airflow (CoolingHeating)
Refrigerant Control
Outdoor Unit Sound Pressure Level at Cooling 1
Sound Pressure Level at Heating 2
External Finish Color
Dimensions
Weight
Total Capacity 22-130
Indoor Unit ModelQuantity
Remote Controller Type
Type
Refrigerant Charge
Oil
Gas Side OD Refrigerant Pipe
Liquid Side OD
Height Difference (Max)
Maximum Distance between (Outdoor unit and farthest indoor unit)
Refrigerant Pipe Length Maximum Pipe Length -Branch box to Indoor Unit
Total Maximum line length between Branch Box and All Connected Indoor Units
Total Length (Max)
Connection Method IndoorOutdoor
Includes both branch boxes if there are two
Branch Boxes (At least one branch box required)
Btuh
W
Btuh
Btuh
W
Btuh
Btuh
W
Btuh
A
A
Type x Quantity
Motor Output (kW)
Model (Type)
Motor Output (kW)
CFM
dB(A)
dB(A)
W In
D In
H In
Lbs
Btuh
Lbs Oz
Type (fl oz)
In
In
Ft
Ft
Ft
Ft
Ft
4800048000
57806470
54000
5400054000
48205270
60000
3300034700
29503390
3660036550
1 Phase 60Hz 208 230V
AC 208-230V
DC12-24V
32
40
Propeller x 2
0086 + 0086
DC INVERTER-driven Scroll
29
3530
Linear Expansion Valve
54
55
Munsell No 3Y 78 11
37-716
13+1-3 16
53-3 16
278
12000 - 70200
600 - 24000 2-8
Associated with Indoor Unit Model
R410A
18 112
FV50S (73)
58
38
6698 4
230
49
197
377
FlaredFlared
Compatible with the MSZ-A MSZ-FO MSZ-FE MSZ-GE MFZ-KA SEZ-KD PLA and PEAD series indoor units
NOTES Test conditions are based on AHRI 210240 One indoor unit is turned off during low-speed testing under the new test conditions Systems actually exhibit higher energy efficiencies during normal operation
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F (35deg C) WB 75deg F (24deg C)
2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 4]0 F (8deg C) WB 43deg F (6deg C)
3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 17deg F (-8deg C) WB 15deg F(-9deg C)
4 66 applies to installations when the outdoor unit is installed below the indoor unit
Power factor equals 97 percent
Specifications are subject to change without notice
Note Maximum installed capacity is the maximum total of all connected indoor units NOT the maximum capacity produced
Only a single Lineset is needed from the outdoor unit to branch box
See page 25 for MXZ-B information on efficiency
Required Branch Boxes for MXZ-SB4BNA (Maximum of 2 branch boxes can be connected to one outdoor unit requires joint MSDD-50AR-E or MSDD-50BR-E)
s c d N o J ro Vl
0 ro n 3i n OJ d o J U)
PAC-AKA51 BC Branch Box
PAC-AKA31 BC Branch Box LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 23
MSZ WALL-MOUNTED INDOOR UNITS (FOR MXZ-8 OUTDOOR UNITS)
R
(MSZ-GE12NA MODEL SHOWN)
-000 IIIIIII 9000 9000 12000 12000 14000 17200
Heating at 4r Rated Capacity Btuh 7200 10900 10900 14400 13600 18000 21600
F2 Power Supply I Phase Cycle Voltage J -phase 60Hz 208 230V 3
Iindoor Outdoor S1 S2 AC 208 230V
Iindoor Outdoor S2 S3 DC12-24V Voltage
Iindoor Remote vomr Iller Wireless Type (Optional Wired vomroller DC 12V)
IMCA A 10 IFan Motor FLA 076
DRY 162-226shy145-170shy
162-226shy205-272shy 230-275shy
Airflow at Cooling (CFM)
145-170-237-321-399 339-381
237 -321shy381-410
335-420shy 339-420shy(Quiet-Lo-Med-Hishy 399 533 533 Super Hi or Lo-Med-
WET 144-202shy109-134shy
144-202shy170-237shy 194-240shy
Fan Hi-Powerful)1 (CFM)
109-134-201-286-364 307-343
201-286shy350-367
300-385shy 304-385shy364 498 498
Airflow at Heating 145-170shy 145-170shy 145-170shy 205-247shy 230-275shy
(Quiet-Lo-Med-Hi- WET 233-321shy 237-321shy
166-240shy237-321shy
166-240shy304-367shy 339-431shy
Super Hi or Lo-Medshy (CFM) 406 406
367 -381 406
399-420 463 512
Hi-Powerful) 2 Sound Pressure Level at Cooling
19-22-30shy 26-32-38shy 28-33-38shy(Quiet-Lo-Med-Hi-Super Hi or Loshy dB(A) 19-22-30-37 -43 22-31-39-42
37-45 22-33-43-45
44-49 44-49Med-Hi-Powerful) 1
Sound Pressure Level at Heating 19-22-30shy 26-30-35shy 28-33-38shy
(Quiet-Lo-Med-Hi-Super Hi or Loshy dB(A) 19-22-30-37 -43 22-31-40-42 37-43
22-23-43-44 40-46 43-48
Med-Hi-Powerful) 2
I External Finish Color Munsell No 10Y 92 02
IWln 31 middot716
Dimension Unit 10 In 9 18 10-18 9middot18 10-18 9-18
IH In 11-58
I Weight Unit ILbs 22 27 22 27 22 I Field Drainpipe ~D lin 58 Remote Con-
Type Wireless Remote (Optional Wired Controller) troller
ITvpe B41QA Refrigerant ~s$ideOD lin 38 Pipe I Liquid Side 00 In 14
Connection IndoorOutdoor FlaredFlared
Method
1~
II 18000 22500
21600 27600
388-469shy 38$-469shy628-738 628-738
347-420shy 347-420shy562-661 562-661
388-469shy 388-469shy628-738 628-738
34-41-49-53 34-41-49-53
32-41-49-52 32-41-49-52
43-516
9-38
12-1316 37
58 38
MXZ-2B20NA is also compatible with the MSZ-A and MSZ-FD series indoor units NOTES Test conditions are based on AHRI 210240
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F(6deg C) 3 Indoor units receive power from outdoor units through field-supplied wiring
Specifications are subject to change without notice LIMITED WARRANTY Seven-year warranty on compressor Five-year warranty on parts For data on specific indoor unit combinations see page 21
SEZ DUCTED INDOOR UNIT (FOR MXZ-8 OUTDOOR UNITS)
I
Notes 1 Cooling-Indoor DS 80deg F(267deg C) WS 67deg F(194deg C) Outdoor DS 95deg F (35deg C) WS 75deg F(239deg C)
2 Heating-Indoor DS 70deg F(211 deg C) WS 60deg F(156deg C) Outdoor DS 47deg F (83deg C) WS 43deg F(61 deg C)
3 External static pressure is factory set to 006 WGAdjustable via the
1---------t---+-----L-------------1~---__I PAR-21MAA
1--_____----__________+-____---L____----~_____________1 4 Indoor units receive power
jE~~~~-------------r----1-----~-~~~~~~~~-----___1 from outdoor units through fieldsupplied interconnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven-year warranty on compressor Five-year
1---------------------+---+------------------------1 warranty on parts
~--__I_~----------+-------~l----------I For data on specific indoor unit combinations see page 21 - 23
I--~------+~-----------~----------r_------------I
- Reference page 17 for SEZ static performance curves
24 MITSUBISHI ELECTRIC
25-30-35-40 26-31-36-41 35-38-42-46
25-30-35-40 28-31-36-41 35-38-42-47
MFZ FLOORLOW WALL INDOOR UNIT (FOR middotMXZ-8 OUTDOOR UNITS)
------shy
-==
Airflow at Heating (CFM) 177-198-219-332 184-201-219-335 261-275-297-434
Voltage
Fan
Airflow at Cooling (Lo-Med-Hi-Super Hi)1
169-205-251-314 251-279-325-394
163-197-241-303 170-207-252-309 241-269-313-379
(Lo-Med-Hi-Super Hi) 2
SLZ CEILING-RECESSED INDOOR UNIT (FOR MXZ-8 OUTDOOR UNITS) EFFICIENCY RATINGS
Voltage
Fan
Galvanized-steel SheetsMunsell 64Y 89 04
Refrigerant Pipe
Model Indoor Unit Type SEER HSPF
MXZ-2B20NA-1
Non-dueted 18 89
Dueted and Non-dueted 1675 87
Dueted 155 85
MXZ-2B20NA-1 ENERGY STAR amp
TAX CREDIT 2 x MSZ-GE09NA 18 89
MXZ-3B24NA
lJon-dueted 175 93
Dueted and Non-dueted 1625 89
Dueted 150 85
MXZ-3B24NA ENERGY STAR amp
TAX CREDIT
2 x MSZ-GE06NA 1 x MSZ-GE09NA
175 93
MXZ-3B24NA ENERGY STAR amp
TAX CREDIT
2 x MSZ-GE06NA 1 x MSZ-GE12NA
175 93
MXZ-3B30NA
Non-dueted 175 105
Dueted and Non-dueted 16 100
Dueted 145 95
MXZ-4B36NA
Non-dueted 18 93
Dueted and Non-dueted 16 5 92
Dueted 150 9 0
MXZ-BB4BNA
Non-dueted 15 87
Dueted and Non-dueted 14B B8
Dueted 147 89
Connection IndoorOutdoor FlaredFlared
Method
Notes 1 Cooling-Indoor DB 80deg F(267deg C) WB 67deg F(194deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(239deg C) 2 Heating-Indoor DB 70deg F(21 1 deg C) WB 60deg F(156deg C) Outdoor DB 47deg F(83deg C) WB 43deg F(61 deg C) 3 Indoor units receive power from outdoor units through field supplied interconnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 25
Notes 1 Cooling-Indoor DB 80deg F(267deg C) WB 67deg F (194deg C) Outdoor DB 95deg F (35deg C)WB 75deg F (239deg C)
2 Heating-Indoor DB 70deg F(211deg C) WB 60deg F (156deg C) Outdoor DB 47 F (83deg C) WB 43deg F (61 deg C)
3 Indoor units receive power from outdoor units through field supplied interco(lnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven -year warranty on compressor Five-year warranty on parts
Presently there is no 1 1 system with the MFZ indoor unit
s c
N o J ro Vl
C ro n ~ n OJ t o J V)
M-SERIES RATING CONDITIONS
INDOOR INTAKE AIR TEMPERATURE
OUTDOOR INTAKE AIR TEMPERATURE
COOLING
MAXIMUM
95degF DB 71 degF WB (MU SUZ MXZ-2B20-13B243B304B36) 90degF DB 73degF WB (MUZY-GE MUZ-FE MUzy-D)
115degF DB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B24 3B304B368B48)
MINIMUM 67degF DB 57degF WB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B201 3B243B304B36)
14degF DB (MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B24 3B304B36) 23degF DB (MXZ-8B48) 6rF DB (MU)
MAXIMUM 80degF DB 6rF WB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B243B304B36)
75degF DB 65degF WB (MUZY-GE MUZY-GA24 MUZ-FE SUZ MXZ-2B20-1 3B243B304B36) 70degF DB (MXZ-8B48)
HEATING
MINIMUM 70degF DB 60degFWB (MUZ-GE MUZ-GA24 MUZ-D MUZ-FE SUZ MXZ-2B20-1 3B243B304B36)
-13degF DB -15degFWB (MUZ-FE) -4degF DB -5degF WB (SUZ MUZ-GE) 5degF DB 4degF WB (MUZ-GA24 MXZ-8B48NA) 6degF DB 5degF WB (MXZ-2B20-1 3B24 3B304B36) 14degF DB 13degFWB (MUZ-D)
MU units operate at intake air temperature down to 10deg Fwith the addition of an ICM-326HM-1 low temperature control
REFRIGERANT TUBING SETS
OPTIONAL ACCESSORIES
REFRIGERANT LINE LENGTH FLARE FLARE _INDOOR UNIT OUTDOOR UNIT
MS-A09WA MU-A09WA 35 MS-A12WA
65 MU-A12WA 35
MSY-GE09NA 65
MUY-GE09NA 40
MSY-GE12NA
65
MUY-GE12NA 65 40
MSY-GE15NA MUY-GE15NA 40
MSY-GE18NA
65
MUY-GE18NA 100 50
MSZ-GE09NA MUZ-GE09NA 65 40
MSZ-GE12NA MUZ-GE12NA 40
MSZ-GE15NA
65
MUZ-GE15NA 40
MSZ-GE18NA
65
MUZ-GE18NA 100 50
MSY-GE24NA MUY-GE24NA 100 50
MSZ-GE24NA MUZ-GE24NA 100 50
MSY-D30NA MUY-D30NA 100 50
MSZ-D30NA MUZ-D30NA 50
MSY-D36NA
100
MUY-D36NA 50
MSZ-D36NA
100
MUZ-D36NA 100 50
MSZ-FE09NA MUZ-FE09NA 40
MSZ-FE12NA
65
MUZ-FE12NA 40
MSZ-GE06091215NA MSZ-FE0912NA
65
MXZ-2B20NA-1 164 4933MFZ-KA0912NA SEZ-KD09 1215NA
MSZ-GE0609 121518NA MSZ-FE091218N MFZ-KA09 1218NA MXZ-3B24NA 164 4933 SEZ -KD09 12 15 18NA SLZ-KA09 12 15NA
MSZ-GE0609 121518NA MSZ-GA24NA MSZ-FE091218NA
MXZ-3B30NA 4933230MFZ-KA091218NA SEZ -KD09 121518NA SLZ-KA09 12 15NA
MSZ-GE0609121518NA MSZ-GE24NA MSZ-FE09 12 18NA
MXZ-4B36NA 230 4933MFZ-KA091218NA SEZ -KD09121518NA SLZ-KA09 12 15NA
MSZ-GE0609 12 15 18NA MSZ-GE24NA MSZ-FE09 12 18NA
MXZ-8B48NA 6698377MFZ-KA091218NA SEZ-KD09121518NA SLZ-KA09 12 15NA
PART NUMBER I USE WITH I DESCRIPTION
Port Adapters and Connection Pipes MAC-A454JP-E MXZ-Series Adapter 38 X12
MAC-A455JP-E MXZ-Series Adapter 12 X38
MAC-A456JP-E MXZ-Series Adapter 12 X58
MSDD-50AR-E MXZ-Series Branch Box Tee Distribution Pipe - Flare Connection between two branch boxes
MSDD-50BR-E MXZ-Series Branch Box Tee Distribution Pipe - Braze Connection between two branch boxes
PAC-493PI MXZ-Series Adapter 14 X38
PAC-SG76RJ-E MXZ-Series Adapter 38 X58
OPTIONAL ACCESSORIES CONTINUED ON NEXT PAGE
49 amp 66 applies to installations in which the outdoor unit is installed below indoor unit26 MITSUBISHI ELECTRIC
OPTIONAL ACCESSORIES (CONTINUED)
PART NUMBER USE WITH DESCRIPTION Control Options and Accessories
M21 JKO 307 M-Series Indoor Units Remote temperature sensor for M-Series indoor units
MAC-397IF-E
MAC-399IF-E
PAC-YU25HT
PAR-21 MM-G
M-Series INVERTER Units
M-Series INVERTER Units
SEZ-KD Indoor Units
Use with P-Series SEZ and for wired M-Series Controller
MA and contact terminal interface - Required to use PAR-21 MM wired wall mount controller with M-Series Systems
CMCN M-NET control adapter I Interface for Mr Slim M-Series MSYZ SEZ I MFZ
External Fan I Heater control relay adapter
Deluxe MA remote controller (Requires MAC-397IF-E for use with M-Series - MSYZ MFZ)
SEZ Wireless remote controller for SEZ units (Requires signal receiver PAR-SA9FA-E)PAR-FL32MA
PAR-SA9CA-E SEZ Wireless signal receiver for SEZ
3-pole disconnect switch 30A 600V turns off power between indoor and outdoor units shyM-SeriesTAZ-MS303
mounts in 2 X 4 utility box and requires standard single gang switch platecover - Low Ambient
ICM-326HM-2 M-Series Non-INVERTER units Low ambient head pressure controller MUZ-GE091215 IVIUZ-FE0912 SUZ-KD091215
Drain pan heaterMAC-640BH-U outdoor unit
MAC-641 BH-U MUZ-GE18 SUZ-KD18 outdoor unit Drain pan heater Filters
MAC-1415FT-E Anti-allergy enzyme filter
MAC-2300FT
MSZlMSY-D3036
Anti -allergy enzyme filter
MAC-308FT
MSYMSZ-GA24
MSZ-FD912 I FE0912 Platinum deodorizing filter
MAC-408FT-E Anti-allergy enzyme filter
MAC-415FT-E
M-Series Indoor Unit - GE09GE12GE15GE18
MFZ-KA Air Cleaning FilterAnti-Aliergy Enzyme Filter
MAC-418FT Anti-allergy enzyme filter
Filter Boxes
FBL1-1
MSZ- FD912 I FE091 2
FB Series Filter Box for SEZ-KD09NA Optional filter box with MERV 8 filters
FB Series Filter Box for SEZ-KD1215NAFBL1-2 Optional filter box with MERV 8 filters
and PEA-A 12M
FBL1-3 FB Series Filter Box for SEZ-KD18NA Optional filter box with MERV 8 filters
Pumps
SI1730-230 MSYZ - 30000 Btuh or greater Sauermann mini condensation pump 230V
S13100-115 MS-Series - non-INVERTER Sauermann mini condensation pump 115V
S13100-230 Sauermann mini condensation pump 230VMSYZ - Less than 30000 Btuh
Miscellaneous BRP-1 Bottom Return Plate for SEZ-KD09NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-2 Bottom Return Plate for SEZ-KD12KD15-NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-3 Bottom Return Plate for SEZ-KD18NA Converts low profile ducted indoor unit from rear return to bottom return
BV12FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderreglnsulated - 12
BV14FSI Use with any Mr Sl im multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 14
BV38FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 38
BV58FSI Use with any IVIr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 58
Condensing unit wall mounting brackets (set of 2) - 440 lb capacity painted steel NOTE CWMB1 IVIU and PU outdoor units Installer is responsible to select and provide suitable hardware and materials to insure proper
mount of bracket to wall
DSD-400N M-Series DiamondBacktrade Platform Stands MUZ-GE18 I MUZ(y)-03036 I
MAC-811DS Drain socket assemblySUZ-KA18
MAC-851DS MUZ-FD0912 Drain socket
MAC-855SG M-Series Air outlet guide
MAC-856SG M-Series Air outlet guide - MXZ-3B24 I 3B30 I 4B36 NA
MAC-860DS MUZ-GE091215 I MUZ-FE0912 Drain socket
MAC-889SG M-Series Air outlet guide- MXZ-2B20NA
MAC-S99SG M-Series Air outlet guide
PAC-SG59SG-E IVIXZ-SB4SNA Air outlet guide (1 piece) I MXZ-SB48NA (Requires 2 pieces)
PAC-SG61 DS-E MXZ-8B4SNA Drain socket - connector
PAC-SG64DP-E MXZ-SB48NA Drain pan
RCMKP1CB lVI-Series Wireless Lockdown bracket for remote controller
lILTRILlTE1 All M-Series Condensing unit mounting pad 16 x 36 x 3
MITSUBISHI ELECTRIC 27
MXZ-8 Series Port Adapter chart Port Adapter Unit Port
Combinations Required Size
MXZ-2B20NA-1
2-zone combinations wi NA
A 38 x both units s12K 14
1-MAC-A454JP-E B 38 x
6+15 14
9+15 1-MAC-A454JP-E
MXZ-3B24NA
All rated 2-zone combina-NA
A 12 x tions 14
All rated 3-zone combina-NA
B 38 x tions 14
C 38 x 14
MXZ-3B30NA
2-zone combinations wi at NA
A 12 x least one unit s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
9 + 24 14
3-zone combinations wi 1-MAC-A455JP-E
all units s12K
All other rated 3-zone NA
comb
MXZ-4B36NA
2-zone combinations wi at NA
A 12 x least one un it s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
6 + 24 14
1-MAC-A456JP-E D 38 x
9 + 24 14
3-zone combinations wi at NA
least two units s12K
3-zone combinations wi 1-MAC-A454JP-E
two units15K
6+6+24 or 6+9+24 1-MAC-A456JP-E
9+9+24 1-MAC-A456JP-E
4-zone combinations wi at 1-MAC-A455JP-E
least three units s12K
6+6+15+15 1-MAC-A454JP-E
6+6+15+15 1-MAC-A454JP-E
Note When using the Pu-A24BA PCA-A24KA or PEAD-A24AA two port adapter will be needed 1-MAC-A456JP-E (12 x 58) A port or 1-PACshySG76RJ-E (38 x 58) B C and D ports and 1-PAC493PI (14 x 38)
28 JMITSUBISHI ELECTRIC
6+6+246+9+24 6+12+249+9+24 9+12+24 or 12+12+24
6+15+24 6+18+24 9+15+249+18+24 12+15+24 or 12+18+24
15+15+24 15+18+24 or 18+18+24
15+24+24 or 18+24+24
Combinations of 4 or more zones
1-PAC-SG76RJ-E
See notes for application below
2
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
See notes for application below
PORT A =38 gas x 14 liquid
PORT B =38 gas x 14 liquid
PORT C =38 gas x 14 liquid
PORT A =38 gas x 14 liquid
PORT B = 38 gas x 14 liquid
PORT C = 38 gas x 14 liquid
PORT D =38 gas x 14 liquid
PORT E =12 gas x 14 liquid
Notes for application bull Check the lineset sizes for your indoor selected models bull Select the branch box or boxes needed for your application bull Compare indoor unit lineset sizes as compared to branch
box sizes bull Connect 15K + indoor units to the larger port on the
(PAC-AKA51 BC) bull Adapt lineset size with appropriate port adapter from
above list bull When using the PU-A24BA or PEAD-A24AA two port
adapter will be needed 1-MAC-A456JP-E (12 x 58) or 1-PAC-SG76RJ-E (38 x 58) and 1-PAC493PI (14 x 38)
-fv
~ DIAMONDBACKtrade
~) BV-Series Ball Valves Model numbers
BV14FFSI BV38FFSI
LISTED 891N REFRIGERANT
BV12FFSI VALVE bull Engineered for Mini-split andBV58FFSI
Multi-split HVAC Units bull Size available 14 38 12 58
bull Full Port Designbull Fully factory assembled bull Furnace brazed and pressure tested bull 700 PSIG Rated bull Each ball valve is equipped with Schraderreg Valve
for refrigerant service bull R-410A Compatible bull Design working pressure 700 PSIG bull Temperature range bull Flare Connections
-40 0 F to +3250 F (-400 C to + 1490
C) bull Forged brass body and seal cap bull Teflonreg seals and gaskets (no synthetic a-rings) bull Seal cap design permits valve operation without
removal of seal cap bull Suitable for use with R-11 R-22 R-123 R-125
R-134A R-236FA R-4202A R-402B R-404A R-407C R-410A R-500 R-502 and R-507
bull One year limited materials and workmanship
Part Number SAE Flare
A B C 0 E F
BV14FFSI 14 619 260 180 122 142 110
BV38FFSI 38 630 267 180 122 142 110
BV12FFSI 12 651 267 180 122 142 110
BV58FFSI 58 664 267 180 128 142 110
Ball valves come With an insulation piece warranty on Ball Valves
~ DIAMONDBACKtrade
~) Platform Stands
Lift the Mitsubishi Electric Comfort Solution
outdoor unit to new heights with our Diamondback Platform Stands
bull Easy to install
bull Available for all sizes of Mr Slim outdoor units
bull Color matched to the outdoor units
Model Number DSD-400N
L 15-34 x W 3-14 x H 3-14
r
)MITSUBISHI ELECTRIC 29
~ DIAMONDBACKtrade LINESETS
~~
Twin-Tube Lineset Insulation Design
bull Balanced outside diameter for uniform coiluncoil position stability
bull Minimum 12 insulation thickness on both tubes Diamondback Advantages include the following features
bull Quick efficient and economical field installation using factory applied Twin Tube insulation and flare connections with flare nuts mounted
bull Correct lengths for reducing waste and time
bull Quality consistency and economy
bull All Diamondback Lineset tubing is tested in accordance with ASTM E243
Filter Boxes
FB Series filter boxes are available in compatible sizes for all Mr Slim horizontal ducted indoor units
FBL 1 filter boxes include 1 thick pleated MERV 8 filter(s) installed Filters are tested in accordance with ANSIASHRAE Standard 522 and Rated Class 2 under UL Standard 900
The cabinet is constructed of non-insulated 20 gauge G-60 galvanized
FBL1-1 FB Series Filter Box for SEZ-KD09NA
FBL1-2 FB Series Filter Box for SEZ-KD12KD15-NA
FBL1-3 FB Series Filter Box for SEZ-KD18NA
steel with foam gasket and provides an air-tight connection to indoor unit and access door Gasket material complies with UL 723 requirements
A screw-through cabinet design for secure attachment to indoor unit and return connection in rear is easily field-converted to bottom return
30 MITSUBISHI ELECTRIC
bull
bull
bull
bull
bull
bull
LINE-HIDE~ Put a professional finish on air-conditioning
installations with an easy-to-install modular
system that beautifies exteriors and
protects Linesets drainlines and wiring
Can be use it indoors too Meets UL94v-O for interior applications
Has snap-on covers and a full selection of couplings elbows T-joints caps and more for any application complex or simple
Offers high-quality PVC with UV inhibitors for outdoor service in all weather conditions
Can be painted with most house paints to match exterior decors
Is not just for HVAC Hide any exterior cabling piping or wiring
Available in four sizes 2-14 3 4 and 6 tubes
Download a brochure at wwwline-hidecom to find out more information
For more information on our CITY MULTI VRF product line visit our website at wwwmitsubishiprocom
_lIJrUlllln ~ ~IIII1 fInll l
~
l bull bull
JMITSUBISHI ELECTRIC 31
SING LE -ROOM HORIZONTAL- DUCTED HEAT PUMPS (coo lin g and heat ing)
WIR ELESS and W IR ED REMOTE C O NTRO LLERS
PAR-21 MAA Wireless remote controller Set Temperature
for wall-mounted and floor-standing indoor units ----- OnOff
Timer Menu Fan Speed
Fan Speed Filter
Test Run Set Time
CheckEcono Cool
Airflow UpDown Timer OnOff
Louver
Ventilation
Reset ---- shy Optional wired controller for the SEZ SLZ and MFZ indoor units (Optional controller for wall-mounted is
available and floor-standing indoor units Unit requires MAC-397 If adapter)
MHK1 WIRELESS REMOTE CONTROLLER Exclusive for INVERTER-driven Mr Slimreg Systems
Wireless Technology a SEZ and SLZ 11 systems with SUZ outdoor unit only
MIFH1
MITSUBISHI ELECTRIC 9
AMITSUBISHI ELECTRIC
l~ 1000
~r t ~~~O
MRCH1
rtj n-shy --1r-a-1-shy
Mode ------ -- shy
SEZSUZ If your customer is looking for discrete zoned comfort then a short-run ducted unit Heat Pumps is the right solution As a stand-alone system or connected to a MXZ multi-room
3800 to 19000 BtuH system the SEZ ducted units provide energy efficiency quiet operation and a Capacity Range compact design for quick easy instqllation hidden either in the ceiling or beneath
15 SEER _---~~mm the floor 175 - 10 HSPF
J ~ All of the 11 systems are ENERGY STAR certified and two systems qualify for
~ the federal tax credit These systems provide customers with an environmentally friendly indoor unit with a similar installation and familiar style
These SEZ indoor units also connect to MXZ multi-zone systems providing a wide array of installation options to best fit any application
SING LE -R OO M C EI LING -REC ESSED CASSETTE UN IT
SLZSUZ Heat Pumps The SLZ -KA ceiling-recessed units casette offer a wide
3100 to 22200 BtuH air-flow pattern for better air distribution in a less obtrusive Capacity Range style These indoor units can be used in 11 heat pump
15 - 16 SEER and multi-zone systems providing more options to your customers Install SLZs in a hard ceiling (with a access panel for
bull 96 HSPF
servicing) or in a 2x2 extra space drop ceiling With a built-in drainshylift mechanism for condensate removal and a 4 ventilation-air intake knockout option and multiple options for the 11 systems the SLZ
~ ~ handles a variety of installation needs
Two of the three 11 systems are ENERGY STAR qualified
Vl l
OQ
(I) I
N o l (I)
Vl ltV (I)
3 Vl r o ~ n OJ V (I)
1shy(MS-A12WA MODEL SHOWN)
MS COOLING-ONLY
IJON-INVERTER
Model Name Indoor Unit
Outdoor Unit
MS-A09WA MS-A12WA
MU-A09WA MU-A12WA
Cooling 1
Rated Capacity Btuh 9500 12000
Capacity Range Btuh
Total Input W 870 1070
Energy Efficiency SEER 13
Moisture Removal Pintsh 27 32 Sensible Heat Factor 068 070
Power Supply Phase Cycle Voltage 1 Phase 60Hz 115V 2
Voltage Indoor - Outdoor L1-N AC 115V Indoor - Outdoor N-2 AC 115V Indoor - Remote Controller Wireless Type
Indoor Unit
MCA A 12
Fan Motor FLA 095
Airilow (Lo-Med-Hi Poweriul)
DRY (CFM) 183-261-335-367 222-286-406-446
WET (CFM) 162-233-300-328 198-254-363-399
Sound Pressure Level (Lo-Med-Hi)
dB(A) 26-32-40-42 33-38-45
External Finish Color Munsell No 1OY 9202
Dimension Unit
W In 30-1116
0 In 8-14
H In 11-34
Weight Unit Lbs 23
Field Drainpipe Size 00 In 58
Outdoor Unit
MCA A 14 16
MOCP (Time Delay) A 15 20
Fan Motor FLA 063 093
Compressor
Model (Type) Single Rotary
RLA 93 1082
LRA 47 56
Airilow CFM 1083 1327
Refrigerant Control Capillary Tube
Sound Pressure Level (Cooling) 1
dB(A) 47 52
External Finish Color Munsell No 3Y 7811
Dimensions
W In 31-12 33-716
0 In 11-14 11-716
H In 21-58 23-1316
Weight Lbs 78 96
Remote Controller Type Wireless Remote
Refrigerant
Type R410A Charge Lbs Oz 25 31
Oil Type (FI Oz) NE022 (108)
Refrigerant Pipe
Gas Side 00 In 38 12
Liquid Side 00 14
Height Difference (Max) Ft 35
Length (Max) 65
Connection Method IndoorOutdoor FlaredFlared
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling) - Indoor DB 800 F(270 e) WB 670 F(190 e) Outdoor DB 950 F(350 e) WB 750 F(240 e) 2 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice
LlIVIITED WARRANTY ISeven-year warranty on compressor Five-year warranty on parts
10 MITSUBISHI ELECTRIC
I
R ---I Vl
J(MSY-GE1 7NA MODEL SHOWN) OQ
MSY COOLI NG-ON LY (CO NT ) CD N o J CD
s Vl OJ J
Cooling 1 0shy
s Vl -lt Vl
~~~~~-=~------~~--------------------------~~~~----------------------------~ jVoltage
205-272-335shy145-170-237 -321-399
420-533 170-237 -300shy
385-498
26-32-38-44-49Indoor Unit
Outdoor Unit
194-240-304shy385-498
28-33-38-44-49
388-469-628-738
347-420-562-661
34-41-49-53
CD n 3-i n OJ 0389-639-848 o J350-576-763 V)
32-42-49
2 9 43Refrigerant
FV50S (040) NE022 (295)
Refrigerant Pipe
Refrigerant Pipe Length
Connection IndoorOutdoor FlaredFlared
Method
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling) - Indoor DB 80deg F(27deg e) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice
LIMITED WARRANTY ISeven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 11
~ (MSZ-FE12NA MODEL SHOWN)
MSZ HEAT PUMP TAX
CREDIT
Model Name
Cooling 1
Indoor Unit Outdoor Unit
Rated Capacity Btuh
MSZ-GE09NA MUZ-GE09NA
9000
MSZ-FE09NA HshyMUZ-FE09NA bull
9000
MSZ-GE12NA MUZ-GE12NA
12000
MSZ-FE12NA MUZ-FE12NA
12000
H-bull MSZ-G MUZ-G
14000
Capacity Range Btuh 3800-12200 2800-9000 3800-13600 2800-12000 3100-18200
Total Input W 660 (205-1200) 580 (160-650) 960 (205-1300) 930 (160-960) 1080 (160-2000)
Energy Efficiency SEER 21 26 205 23 21
Moisture Removal Pintsh 15 21 25 29 27
Sensible Heat Factor 082 076 074 073 080
Heating at 47deg F 2
Rated Capacity Btuh 10900 10900 14400 13600 18000
Capacity Range Btuh 4500-14100 3000-18000 5500-18100 3000-21000 4800-20900
Total Input W 760 (255-1200) 710 (150-2250) 1170 (340-1660) 950 (150-2250) 1600 (270-2010) HSPF (IV) BtuhlW 10 106 10
Heating at 17deg F3 Rated Capacity Btuh 6600 6700 8800 8300 11300 Rated Total Input W 700 650 900 800 1150 Maximum Capacity Btuh 8700 12500 11200 13600 15900
Heating at 5deg F Maximum Capacity Btuh 7061 10900 9194 12500 13022
Power Supply Phase Cycle Voltage 1-phase 60Hz 208 230V 4
Voltage
Indoor - Outdoor S1 - S2 AC 208 230V
Indoor - Outdoor S2 - S3 DC12-24V
Indoor - Remote Controller Wireless Type (Optional Wired Controller DC 12V)
Indoor Unit
MCA A 10
Fan Motor FLA 076
Airflow at Cooling (Lo-Med-Hi-Super HI-Powerful) 1
DRY (CFM) 145-170-237-321-399 162-226-339-381 145-170-237-321-399 162-226-381-410 205-272-335-420-533
WET (CFM) 109-134-201-286-364 144-202-307-343 109-134-201-286-364 144-202-350-367 170-237-300-385-498
Airflow at Heating (Lo-Med-Hi-Super HI-Powerful) 2
WET (CFM) 145-170-237-321-406 166-240-367-381 145-170-237-321-406 166-240-399-420 205-247 -304-367-463
Sound Pressure Level at Cooling (Lo-Med-Hi-Super HI-Powerful) 1
dB(A) 19-22-30-37-43 22-31-39-42 19-22-30-37-45 22-33-43-45 26-32-38-44-49
Sound Pressure Level at Heating (Lo-Med-Hi-Super HI-Powerful) 2
dB(A) 19-22-30-37-43 22-31-40-42 19-22-30-37-43 22-33-43-44 26-30-35-40-46
External Finish Color Munsell No 10Y 92 I 02
Dimension Unit
Wln 31-716 31-38 31-716 31-38 31-716
0 In 9-118 10-18 9-18 10-18 9-18
H In 11-58
Weight Unit Lbs 22 27 22 27 22
Field Drainpipe Size 00 In 58
Outdoor Unit
MCA A 12
MOCP A 15
Fan Motor FLA 050 056 050 056 050
Compressor
lVIodel (Type) DC INVERTER-driven DC INVERTER-driven Twin
Rotary DC INVERTER-driven DC IIWERTER-driven Twin Rotary
RLA 66 86 66 86 74
LRA 82 108 82 108 93
Airflow (CoolingHeating) CFM 11511225 1102 11187 12291172 1102 11187 12431229 Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(A) 46 48 49 48 49
Sound Pressure Level at Heating 2 dB(A) 50 49 51 49 51
External Finish Color Munsell No 3Y 78 11
Dimensions
Wln 31-12
0 In 11-114
H In 21-58
Weight Lbs 66 80 77 80
Remote Controller Type Wireless Remote (Optional Wired Controller)
Refrigerant
Type R410A
Charge Lbs Oz 112 29
Oil Type (fl oz) NE022 (108) NE022 (152)
Refrigerant Pipe Gas Side 00 In 38 12
Liquid Side 00 In 14 14
Refrigerant Pipe Length Height Difference (Max) Ft 40
Length (Max) Ft 65 I
Connection Method IndoorOutdoor FlaredFlared
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg e) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg e) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg e) Outdoor DB 47deg F(8deg e) WB 43deg F(6deg e) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg e) Outdoor DB 17deg F(-8deg e) WB 15deg F(-9deg e) 4 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice
12 +MITSUBISHI ELECTRIC LIMITED WARRANTY ISeven-year warranty on compressor Five-year warranty on parts
- shy(MSY(Z)-D30NA MODEL SHOWN)
Vl J
09 (I)
I
N o J (I)
s Vl N Vl
-0 (I) n 31 n OJ 0 o J V)
Model Name Indoor Unit MSZ-GE18NA MSZ-FE18N MSZ-GE24NA MSZ-D30NA MSZ-D36NA
Outdoor Unit MUZ-GE18NA MUZ-FE18rK MUZ-GE24NA MUZ-D30NA MUZ-D36NA Rated Capacity Btuh 17200 18000 22500 30700 33200
Capacity Range Btuh 3700-18700 8200-25200 8200-31400 9800-30700 9800-33200
Total Input W 1640 (240-2070) 1270 (570-2280) 1800 (570- 3580) 3850 (620-3850) 4360 (620-4360) Cooling 1
Energy Efficiency SEER 192 202 190 145
Moisture Removal Pintsh 46 27 27 99 11 3
Sensible Heat Factor 071 084 075 064 062
Rated Capacity Btuh 21600 21600 27600 32600 35200
Capacity Range Btuh 3500-25200 7500-29700 7500-36900 8700-34000 8700-36000 Heating at 47deg F 2
Total Input W 1900 (230-2680) 1540 (520-2240) 2340 (520- 3650) 3360 (520-3600) 3840 (520-4100)
HSPF (Region IV) BtuhIW 10 103 10 82
Rated Capacity Btuh 13400 11700 16000 19500 21800
Heating at 17deg F 3 Total Input W 1450 2180 3290 2400 2820
Maximum Capacity Btuh 17200 19300 24600 20800 22800 Heating at 5deg F
Maximum Capacity Btuh 13562 21 600 21160 16305 19090
Power Supply Phase Cycle Voltage 1 Phase 60Hz 208230V 4
Indoor - Outdoor S1-S2 AC 208 230V Voltage Indoor - Outdoor S2-S3 DC12-24
Indoor - Remote Controller Wireless Type (Optional Wired Controller DC12V) MCA A 10 Fan Motor FLA 076
DRY (CFM) 230-275-339-420-533 388-469-628-738 388-469-628-738 389-639-848 Airilow (Cool) (Lo-Med-Hi-Super HI-Poweriul) 1
WET (CFM) 194-240-304-385-498 347-420-562-661 347-420-562-661 350-576-763
Airilow (Heat) (Lo-Med-Hi-Super HI-Poweriul) 2 DRY (CFM) 230-275-339-431-512 388-469-628-738 388-469-628-738 445-639-848
Sound Pressure Level (Cooling) (Lo-Med-Hi-Super 28-33-38-44-49 34-41-49-53 34-41-49-53 32-42-49
HI-Poweriul) 1
Sound Pressure Level (Heating) (Lo-Med-Hi-Super dB(A)
Indoor Unit 28-33-38-43-48 32-41-49-52 32-41-49-52 34-42-49-49HI-Poweriul) 2
External Finish Color Munsell No 1 OY 9202
W In 31-716 43-516 46-116
Dimension Unit D In 9-18 9-38 11-58
H In 11-5 8 12-1316 14-38
Weight Unit Lbs 22 37 40
Field Drainpipe Size OD In 58
MCA A 14 171 21
MOCP A 15 20 25
Fan Motor FLA 093
Model (Type) DC INVERTER-driven Twin Rotary
Compressor RLA 100 129 16
LRA 125 161 20
Airilow CFM 1730 1659 17691 701 1941
Outdoor Unit Refrigerant Control Linear Ex~ansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(A) 54 55 56
Sound Pressure Level at Heating 2 dB(A) 56 55 57
External Finish Color Munsell No 3Y 7811
W In 33-116
Dimensions D In 13
H In 33-716 34-58 33-716
Weight Lbs 119 141
Remote Controller Type Wireless Remote (Optional Wired Controller)
Type R410A
Refrigerant Charge Lbs Oz 3 7 43 410
Oil Type (FI Oz) NE022 (152) FV50S (135) NE022 (29)
Gas Side OD 12 58In
Refrigerant Pipe Liquid Side OD 14 38
Height Difference (Max) 50
Length (Max) Ft
100 I Connection
Mpthon IndoorOutdoor Flared Flared
NOTESTest conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg C) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F (24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F(6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 17deg F(-8deg C) WB 15deg F(-9deg C) 4 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice LIMITED WARRANTY ISeven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 13
(SEZ-KD12NA MODEL SHOWN)
SEZ HEAT PUMP TAX
CREDIT
Model Name Indoor Unit SEZ-KD09NA4 SEZ-KD12NA4 SEZ-KD15NA4 SEZ-KD18NA4
Outdoor Unit SUZ-KA09NA SUZ-KA12NA SUZ-KA15NA SUZ-KA18NA Rated Capacity Btuh 8100 11500 14100 17200
Capacity Range Btuh 3800-10900 3800-13300 3800-17000 3800-19000
Cooling 1 Total Input W 670 920 1170 1380
Energy Efficiency SEER 15 16 155 175 Moisture Removal Pintsh 15 24 26 34 Sensible Heat Factor 080 076 080 079
Rated Capacity Btuh 10900 13600 18000 21600
Heating at 4YO F 2 Capacity Range Btuh 4800-14100 4800-16400 4800-21100 4800-24900
Total Input W 1020 1140 1500 1700 HSPF(lV) BtuhIW 100 Rated Capacity Btuh 6700 9000 11900 13100
Heating at 1 yo F 3 Rated Total Input W 810 920 1200 1350 Maximum Capacity Btuh 7300 9800 13700 15000
Power Supply Phase Cycle Voltage 1 Phase 60Hz 208 230V 4 Indoor - Outdoor S1 - S2 AC 208-230V
Voltage Indoor - Outdoor S2 - S3 DC 12-24V Indoor - Remote Controller See optional accessories chart (pg 26 and 27) MCA A 1 Fan Motor FLA 051 057 074
Airflow (Lo-Med-Hi) DRY (CFM) 194-247-317 247-317-388 353-441-529 423-529-635
WET (CFM) 174-222-285 222-285-349 317 -396-4 76 381-476-572 External Static Pressure 3 In wG 002-006-014-020 Sound Pressure Level dB(A) 23-26-30 23-28-33 30-34-37 30-34-38
Indoor Unit External Finish Galvanized-Steel Sheets
W In 31-18 39 46-78
Dimension Unit D In 27-916
H In 7-78
Weight Unit Lbs 42 50 54 62 Field Drainpipe Size 00 In 1-14
MCA A 12 14
MOCP A 15 Fan Motor FLA 050 093
Model DC Inverter DC Inverter Twin Rotary
I (Type)Compressor
RLA 66 74 10
LRA 82 93 125
Airflow (CoolingHeating) CFM 11511225 12291172 1 2431 229 17301659
Outdoor Unit Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(A) 46 49 54 Sound Pressure Level at Heating 2 dB(A) 50 51 56
External Finish Color Munsell No 3Y 7811
W In 31-12 33-16
Dimensions D In 11-14 13
H In 21-58 33-716
Weight Lbs 66 77 80 119 Remote Controller Type See optional accessories chart (pg 26 and 27)
Type R410A
Refrigerant Charge Lbs Oz 116 2 9
Type (fl Oil
oz) NE022 (108)
Refrigerant Pipe Gas Side OD In 38 Liquid Side 00 In 14
Refrigerant Pipe Height Difference (Max) Ft 40 Length Length (Max) Ft 65
Connection IndoorOutdoor FlaredFlared
Method
316
NE022 (152)
12
50
100
I
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg C) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F(8deg C) WB 43deg F(6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 17deg F(-8deg C) WB 15deg F(-9deg C) 4 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
14 MITSUBISHI ELECTRIC
SEZ STATIC PERFORMANCE CURVES (SEZ-KD12NA4 MODEL SHOWN)
SEZ-KD09NA4 SEZ-KD09NA4 (External static pressure O06[inwG]) 208230V 60Hz
[020] V L
5 [016
~l [0 12
]
SEZ-KD09NA4
~ ltij
~ [008
Jj
]
]
[004J ~
V V Middle
Low
V
19h
Rated point
1
o [141] [176J 1212) )247] [282J [318]
Airll ow rat e [CFM)
SEZ-KD12NA4 (External static pressure O06[inwG]) 208230V 60Hz
[020
5 [016
]
]
[353J
Limit
]
~ V
~ [ [0 12
u ltijJ[008
[004
]
_V ]~ Low
V
k-iddle
Rated POint
o [212) [247] [2 82] [318] [353] [388]
Airtlow rate [C FM]
SEZ-KD1SNA4 (External static pressure O06[inwGl) 208230V 60Hz
[424)
1020]
5 [016
~ ~ [012
~ ltij
~ [008
Jj
J
)
]
[004 ]
o
VV V [ Low
VV
vV High
Middle
I Rated point
[282] [318) [353] [388] [424] [459] [494] [530] [565J
Airllow rat e [CFM]
SEZ-KD18NA4 (External static pressure O06[inwG]) 208230V 60Hz
50 10 20]
] 40
5 [016
s 30 [ (012 )
ltij 20 ~ [008 )~Jj
10 [004]
V
Low
v Limit
rIV High
V [ Middle
~
1
Rated point
f318) [353) [388] [424] [459] [494] [530] [565] [600] [636] [671 )
Airllow rate [CFM]
(External static pressure O14[inwG]) 208230V 60Hz 80
[0 32
70 [028
5 60 [024
20 [0 08
10 [004
]
]
J
]
]
J
]V
]
U~it
V
k
High
~V Rated POI~1 V Middle Low
~
o [141] [1 76] 12121 )247J [282] [318]
Airtlow rate [CFM)
SEZ-KD12NA4 (External stat ic pressure O14[inwG]) 208230V 60Hz
[032]
[028J
5
[353]
J
~ [024
-~ [020] V-is
J V Il Hi9h Rated point
[016
~ ]
V V1 Middle
~ [012
[008]~
[004)
o [212)
[247)
SEZ-KD1SNA4
Low r
[282] [31 8) [353]
Airllow rale [CFM]
[388]
(External static pressure O14(inwG]) 208230V 60Hz
[032J
[424
]
2 V[028
5 [024]
V-i
] V High i [020
] K
Middle Rated point [0 16
g ]
~ -
QJj [0 12
J Low
[008
] I
~
[004
o [282J [318) [353J [388J [424) [459] [4 94] [530) [565)
Airt low rate [CFM]
SEZ-KD18NA4 (External statiC pressure O14(inwG]) 208230V 60Hz
1032
1028
~ 1024
-~ [0 20
is (0 16 ltij E ~ [012
(008
(004
o
I
]
]
)
]
)vlt ]
]
~ V
VV
Low
Limit
V
Ji9h
Middle l
Rated point
1 t
1
~ [318] [353] [388] [424] [459) [4 94] [530) [565) [600] [636] [671)
Airllow rate [CFM]
(External static pressure O20(inwG]) 208230V 60Hz
[032 ]
[028 J
5 [024
~ [020
is [016
1 [012Jj
[008
[004
J
]
]
] )
]
V Low
umz V High
~V
Rated point
Middle
1
[141] [176] [212) [247) [282) [318) [353J
Airtlow rat e [CFM]
SEZ-KD12NA4 (External static pressure O20(inwG]) 208230V 60H z
[032 ] LLimit
)
[0 28
5 ]
V
[024 -~ [020] V Rated point
Highis ~
) V
bull Middle
]~V I
[016
~ ~ [012
] Low
[008
]
[0 04
o [212) [247] [282] [318] [353] [388] [424]
Airllow rate [CFM]
SEZ-KD1SNA4 (External static pressure O20(inwG]) 208230V 60Hz
80 [032 ]
70 [0 28
~ [ O~~ -
ltij
E 30 ~ [0 12
20 [008
10 [004
o
)
J
]
]
JV
J
J
Limit V
LV High
V ~
K Rated point
Middle
VV 1gt
Low
I-
~ [282) [318) (353] (388) (424) 1459] [494] 15301 [565)
Airtlow rate [CFM]
SEZ-KD18NA4 (External static pressure O20[inwG]) 208230V 60Hz
[032
[028
~ [024sect
I [020
~ [016
~ Jj [0 12
[008
[004
o
]
)
]
]
]
~ )
]
]
1V
V 1
V
Low
1 limit
~~~ I ~~ High
~ R~ted pOini
Middle
1 1 -
[31 8) [353] [388] [424) [459] [494] [530] (565) [600] (636) [671J
Airllow rate [CFM)
Vl ~ ca (I)
I
N o ~ (I)
Vl m N Vl
-0 (I) n 3-i n QJ ~ o ~ tn
Note ESP 20S230V 60 Hz See manual for Static Performance Curve including 002 in WG
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts ~MITSUBISH[ ELECTRIC 15
SLZ HEAT PUMP (SLZ-KA12NA MODEL SHOWN)
Model Name Indoor Unit SLZ-KA09NA SLZ-KA12NA SLZ-KA15NA
Outdoor Unit SUZ-KA09NA SUZ-KA12NA SUZ-KA15NA Rated Capacity Btuh 8400 11100 15000
Capacity Range Btuh 3100-10900 3100-13300 3100-22200
Cooling 1 Total Input W 700 920 1460
Energy Efficiency SEER 15 154 16 Moisture Removal Pintsh 12 23 45 Sensible Heat Factor 080 076 080
Rated Capacity Btuh 10900 13 600 18000
Heating at 4r F 2 Capacity Range Btuh 3100-14100 3100-17100 3100-17100 Total Input W 930 1180 1950 HSPF (IV) BtuhIW 96 Rated Capacity Btuh 6200 8300 10200
Heating at 17deg F 3 Rated Total Input W 740 930 1310 Maximum Capacity Btuh 8300 10200 12000
Power Supply Phase Cycle Voltage 1 Phase 60Hz 208 230V 4 Indoor - Outdoor S1 - S2 AC 208-230V
Voltage Indoor - Outdoor S2 - S3 DC 12-24V
Indoor - Remote Controller See optional accessories chart (pg 26 and 27) MCA A 1 Fan Motor FLA 023 028 028
Airflow (Lo-Med-Hi) DRY (CFM) 280-320-350 280-320-390 280-320-390
WET (CFM) 250-290-320 250-290-350 250-290-350
Sound Pressure Level dB(Al 29-32-38 30-34-39 31-35-40
Indoor Unit External Finish Galvanized-Steel Sheets Grille Munsell 64Y 8904
W In 22-7 16 (25-58)
Dimension Unit (Grille) D In 22-716 (25-58
H In 8-316 (1316)
Weight Unit (Grille) Lbs 36 (7) Field Drainpipe Size 0 0 In 1-14 MCA A 12 MOCP A 15 Fan Motor FLA 050
Model (Type) DC INVERTER-driven DC INVERTER-driven
Compressor RLA 66
LRA 82
Airflow (CoolingHeating) CFM 11511225 1 229 1 172
Outdoor Unit Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(AJ 46 49 Sound Pressure Level at Heating 2 dB(AJ 50 51
External Finish Color Munsell No 3Y 781 1
W In 31 shy12
Dimensions 0 In 11-14
H In 21-58
Weight Lbs 66 77
~e R410A
Refrigerant Charge Lbs Oz 1 16
Oil Type (fl oz) NE022 108)
Refrigerant Pipe Gas Side 0 0 In 38 Liquid Side 00 In 14
Height Difference (Max) Ft 40 Refrigerant Pipe Length
Length (Max) Ft 65
Connection Method IndoorOutdoor FlaredFlared
29
Twin Rotary 74
93
12431 229
80
NE022 l152) 12
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg C) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F(8deg C) WB 43deg F(6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 17deg F(-8deg C) WB 15deg F(-9deg C) 4 Indoor units receive power from outdoor units through field-supplied interconnectedwiring Specifications are subject to change without notice
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
16 MITSUBISHI ELECTRIC
MHK1 WIRELESS REMOTE CONTROLLER KIT Exclusive for INVERTER-driven Mr Slimreg Systems VlWireless Technology a J
JMITSUBISHI ELECTRIC
Wireless Receiver
MHK1 Kit includes
09 mMRCH1 WIRELESS REMOTE CONTROLLER I Nbull Backlit easy-to-read display o
bull Dual setpoint control with system changeover J m
bull Enabled with RedLlNKTM reliability
bull Compatible with MCCH1 Vl Portable Central Controller m
N bull Installs Anywhere Vl
MFH1 WIRELESS RECEIVER N Vlbull Required for MRCH1 Wireless
CRemote Controller m bull Enabled with RedLiNK reliability n
31 n OJ o J en
SEZ and SLZ 11 systems with SUZ outdoor unit
Function Description
ONOFF OnOff operation for a single indoor unit
Operation Mode Cool I Drying I Auto I Heat I Fan only Available operation modes dependant on connected system
Temperature Setting Set temperature from 50degF - 8rF depending on operation mode and connected system
System Changeover Deadband Value 2-8degF
Schedule Operation 5-25-1-1
Fan Speed Setting HiMid-2Mid-1 IlowlAuto Available fan speed settings dependant on connected system
Air Flow Direction Setting Air flow angles 100deg - 80deg - 60deg - 40deg and oscilate Available air flow direction settings dependant on connected system
PermitProhibit Function Individual prohibit operations for each remote controller function (ONI OFF Set Temperature and Operation Mode)
Space Temperature Displays the measured space temperature
Error Indication Displays error code
Display Outside Temperature and Humidity
Requires optional MOS1 Outside Air Sensor
Dimensions - ryv x D x H) Remote Controller 5-316 x 1-12 x 3-916 Receiver 3-14 x 1-516 x 6-716
Operating Ambient Temperature Remote Controller 32 - 120degF Receiver -40 - 165degF
Operating Ambient Humidity Remote Controller 5 - 90 RH (non-condensing) Receiver 5 - 90 RH (non-condensing)
Power Supply 2 AA batteries
MRCH1 MIFH1 MRC1
Wireless Wall-Mounted Remote Controllers Wireless Receiver Cable
Accessories MCCH1 MOS1
Portable Central Controllers Outside Air Sensor
MITSUBISHI ELECTRIC 17
MULTIPLE ROOMS WITH INDIVIDUAL CONTROL FROM A SINGLE SYSTEM Enjoy ideal levels of comfort in the rooms you use most with our multi-room system Each room (zone) operates independently People in different rooms - the kitchen master bedroom or living room - can enjoy temperature settings that make each of them most comfortable
If you re looking for a complete comfort solution for several different rooms the MXZ multi-room system is the right choice The system is flexible enough to conform to a particular cooling and heating need and offers numerous different indoor unit combinations In addition up to eight indoor units can be connected to one outdoor unit Now with a SEZ horizontal ducted unit and a MFZ floorshystanding unit homeowners can enjoy an even greater range of zoning options provided by an MXZ system
An MXZ multi-room system is an excellent choice for supplementing capacity to a current system conditioning newly furnished spaces or new additions and replacing a system within a home Homeowners can also benefit from lower energy costs year-round while staying comfortable thanks to Mitsubishi Electrics energy-efficient technologies that are a part of every system that we make
To add to the level of energy efficiency the MXZ -2B20NA and MXZ -3B24NA systems qualify for both ENERGY STARreg and the federal tax credit (See details on page 21 for applicable indoor unit combinations)
At right a single level home with several system types represented (For illustrative purposes only)
MFZ Floor-Standing Indoor Units for MXZ Heat Pump Systems
Floor-standing indoor unit mounts three inches above the floor and has front panel access to the filter for ease of cleaning
The MFZ units provide energy-efficient solutions to provide personalized comfort for difficult areas that may be smaller or dont have usable space on the walls
MFZ units on MXZ systems include the following features bull Top and bottom discharge vanes bull Hot-start technology bull Quiet operation bull Wireless remote control (optional wall-mounted controller)
18 MITSUBISHI ELECTRIC
MSZ Wall-Mounted Indoor Units for MXZ Heat Pump Systems
Providing a wide range of cooling and heating capacities each wall-mounted indoor unit mounts high on a wall and connects to a branch box or the outdoor unit by a refrigerant line run via a 3 hole The MSZ units provide highly efficient solutions to cooling and heating needs and provide personalized comfort for the individual zones in which they are installed
MSZ units on MXZ systems include the following features bull Sleek flat panel design bull Hot-start technology bull Quiet operation bull i-seeM sensor technology (MSZ-FE0912NA models only) bull Enhanced filtration system (MSZ-FE0912NA models only) bull Wireless remote control (optional wired wall-mounted controller)
SLZ Ceiling-Recessed Indoor Units for MXZ Heat Pump Systems
The new SLZ-KA ceiling casette systems offer a wide air-flow pattern for better air distribution
offered to your customers Installation can be done in a hard ceiling (with a access panel for servicing) or placed into a 2x2 drop ceiling With a built-in drain lift mechanism for condensate
removal and a 4 ventilation air intake knockout option the SLZ is ready to handle a variety of installation needs
SLZ units on MXZ systems include the following features bull Wide air-flow pattern for better air distibution bull 4 ventillation air intake knockout bull Built-in condensate lift mechanism bull Wireless RedLlNKTM remote controller
SEZ Horizontal Ducted Indoor Units for MXZ Heat Pump Systems
SEZ ducted units can provide split air-conditioning system advantages with the added benefit of being concealed to provide virtually no visual footprint within the conditioned space other than a register and grille for the air to flow With the use of short run ductwork these units can provide comfort to a single room that needs air dispersed evenly throughout the space unusually shaped rooms and adjacent rooms
The SEZ unit on MXZ systems include the fOllvowin fatures _
g~e~~~~==Zl[bull Concealed design for short-run ductwork bull Quiet operation bull Built-in condensate lift mechanism
JMITSUBISHI ELECTRIC 19
s c t
I
N o J ro o ltro ~ ro ~
DIAMOND COMFORT MXZ MULTI-ZONE SYSTEMS MXZ-B Series multi-zone systems provide personalized comfort control and energy efficiency in up to eight rooms with only a single outdoor unit The MXZ-B Series system features include
bull Individual zone control bull Mix and match flexibility of indoor unit styles and combinations bull A wide range of indoor unit capacities that match the room size and requirements bull Flexible design options to tackle the most challenging multi-room installations bull Efficient systems including three systems [mxz series] that meet energy starltID and
federal tax credit requirements bull Simple quick and cost-effective installation keeps install costs down on new construction
and disruption to a minimum on renovations and refits
Efficiency and performance ratings depend on the number style and capacity of the indoor units installed with each Multi-Zone System
MXZ -2 B20 NA - 1 (2 1 ) MXZ -3 B24 NA (2 13 1) Ou tdoo r Unit Outdoor Uni t
MSZ-GE09NA Indoor Units
SEZ-KD12NA Indoor Unit
MSZ- GE06NA
~~~~li
(At least two indoor units MSZ-GE06NAIndoor Unit must be installed) Indoor Unit
(Two indoor units must be installed )
MXZ -3 B30 NA (2 1 3 1) Outdoor Unit
SEZ-KD12NA Indoor Unit
~~~i
(At least two indoor units MSZ-GE06NA must be installed)
Indoor Unit ~
MFZ- KD12NA Indoor Unit
MXZ-8B48NA (2 1-8 1) Outdoor Unit
(At least two indoor units
must be installed)
(At least two indoor units must be installed)
MFZ-KD09NA Indoor Units
MSZ-GE09NA Indoor Units
SEZ-KD12NA Indoor Unit
MSZ INDOOR UNIT
MSZ-FE18NA
PEAD HORIZONTAL -DUCTED INDOOR UNIT
PEAD-A24AA
MSZ INDOOR UNIT SEZ HORIZONTAL-DUCTED MSZ-FE18NA
INDOOR UNIT MFZ FLOOR-STANDING SEZ-KD18NA INDOOR UNIT
MFZ-KA12NA
20 AMITSUBISHI ELECTRIC
MULTI-ROOM MXZ-8 INVERTER HEAT PUMP R
Model Name Outdoor Unit MXZ-2B20NA-1 5 MXZ-3B24NA 6 MXZ-3B30NA MXZ-4B36NA 7
Indoor Unit
Cooling 1 Non-ductedl Ducted
Rated Capacity Btuh 1800020000 2200023600 28400127400 3540034400
Capacity Range Btuh 7800-20000 12600-25500 12600-28400 12600-36400
Total Input W 2190 (630-219QL 2460 (1000-2950) 3330 l1 000-3330) 3 940 (1 000-4020)
Heating at 4JO F 2 Non-ductedl Ducted
Rated Capacity Btuh 2200022000 2500024600 2860027600 3600034400
Capacity Range Btuh 8500-25500 11400-30600 11 400-36000 11400-43000
Total Input W 2620 (520-2620) 1900 (740-2600) 2220 (740-2820) 3100 (740-3940)
Heating at 1JO F 3 Non-ductedl Ducted
Rated Capacity Btuh 1250012500 1400014000 1600015100 2220020300
Rated Total Input W 13501430 13801570 21202 140 24302340
Maximum Capacity Btu h 1450014500 1880017000 1880018000 2460025400
Maximum Total Inl2ut W 15001590 21202230 21202140 33403450
Power Supply Phase Cycle Voltage 1-phase 60Hz 2081 230V 8
Voltage Indoor shy Outdoor S1 - S2 AC 2081 230V
Indoor shy Outdoor S2 - S3 DC12-24V
Outdoor Unit 4
MCA A 15 19
MOCP A 20
Fan Motor FLA 096 093
Compressor
Model (Type)
DC INVERTER-driven Twin Rotary
RLA 101 11 144
LRA 15
Airflow (CoolingHeating) CFM 14851 640 20681605 13651605 20682068
Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1
dB(A) 49 54 49 54
Sound Pressure Level at Heating 2
dB(A) 51 49 57
External Finish Color Munsell No 30Y 781 1
Dimensions
W In 33-116 35-716
D In 13 12-58
H In 27-1516 35-7116
Weight Lbs 130 150 153
Indoor Unit No of Units 2 23 23 234
Remote Controller Type Associated with the Indoor Unit
Refrigerant
Type R410A
Charge Lbs Oz 515 7 11 813
Oil Type (fl oz)
NE022 (237) NE022 (294)
Refrigerant Pipe Gas Side 00 In AB 38 A 12 BC 38 A 12 BCD 38
Liquid Side 00 In 14
Refrigerant Pipe Length Height Difference (Max) Ft 4933 9
Length (Max) Ft 164 (A+B) 230 (A+B+C) 230 (A+B+C+D)
Connection Method IndoorOutdoor FlaredlFlared
Compatible with the MSZ-A MSZ-GA MSZ-FD MSZ-FE MSZ-GE MFZ-KA and SEZ-KD series indoor units (PLA-18 amp PCA-24 on the MXZ-MXZ-3B PLA-24 amp PCA-24 on the MXZ-4B)
NOTES Test conditions are based on AHRI 210240 One indoor unit is turned off during low-speed testing under the new test conditions Systems actually exhibit higher energy efficiencies during normal operation
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F (35deg C) WB 75deg F (24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F (6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 600 F (160 C) Outdoor DB 17deg F (_80 C) WB 150 F (_90 C) 4 Refer to pages 12 and 13 for Indoor Unit specifications 5 Data from combination of two Indoor Units 9000 Btuh (non-ducted) or one 9000 Btuh and one 12000 Btuh (ducted) 6 Data from combination of two Indoor Units 6000 Btuh and one 9000 Btuh (non-ducted) or three 9000 Btuh (ducted) 7 Data from combination of four Indoor Units 9000 Btuh (non-ducted and ducted) 8 Indoor units receive power from outdoor units through field-supplied interconnected wiring 9 49 Applies to installations where the outdoor unit is installed below the indoor unit
Power factor equals 97 percent
Specifications are subject to change without notice
MULTI-ZONE ENERGY STAR AND TAX CREDIT SYSTEMS
Model Indoor Unit Combinations SEER HSPF
MXZ-2B20NA-1 2 x MSZ- GE09NA 18 8 9
MXZ- 3B24NA 2 x MSZ- GE06NA 1 x MSZshy GE09NA
17 5 9 3
MXZ- 3B24NA 2 x MSZ-GE06NA 1 x MSZ- GE12NA
17 5 93
For more details on all ENERGY STAR and tax credit systems go to wwwmitsubishicomfortcomtaxcredit
See page 25 for additional info on efficiency
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 21
MXZ-8B48NA THE ULTIMATE ZONING SOLUTION
The Mitsubishi Electric MXZ-S84SNA eight-zone unit As a member of the expanding MXZ-B Series of multi-zone systems the MXZ-8B outdoor unit incorporates branch boxes to connect up to eight indoor units MXZ- 8 B48 NA (2 1 - 8 1 )
Outd oor Uni t The INVERTER-driven compressor at the heart of the MXZ-8B -~-- shy
outdoor unit provides variable capacity control allowing the system to adjust to the specific demands of the interior space ~ as needed not the hard start and stop of a traditional system I[iDA Jinstalled in most US homes
The MXZ -8B48NA has only one port on the outdoor unit for two insulated refrigerant lines which run into the home or business to connect to a branch box or boxes From the branch box(es) gas and liquid refrigerant piping run to each of the indoor units The LEV in the branch box(es) controls the refrigerant flow as the load of each zone changes
Through the branch box(es) (the PAC-AKA31 BC three-port andor the PAC-AKA51 BC five-port) the system can connect from two indoor units up to eight indoor units depending on application requirements
The flexibility of the system doesnt stop there The MXZ-8B48NA has rated capacities of 48000 Btuh for cooling and 54000 Btuh for heating System operation however can range from a minimum 12000 Btuh to a maximum 54000 Btuh in cooling and a maximum of 60000 Btuh in heating This type of performance supports a large variety of applications
The MXZ-8B48NA allows for further flexibility because it supports a connected indoor unit capacity from 22 to 130 or 12000 Btuh to a maximum 70200 Btuh depending on diversity
Connectable Indoor Units General Features bull Four-ton outdoor unit can support up to
eight indoor units using branch boxes bull Wide variety of indoor unit styles
-=--_-=-----= - - J _ 1
including wall-mounted floor-standing MSZ-FE09 12 18NA MSZ-GE06 09 12 15 18 24NA ceiling-cassette ducted
bull Individual control up to eight (8) zones using wired or wireless controls
bull Advanced microprocessor control bull Auto restart following a power outage bull Self-check function offering SEZ-KD09 1215 18NA PEAD-A24AA
integrated diagnostics ~--- Jbull Limited warranty five years on parts and
defects and seven years on compressors
SLZ-KA09 1215NA MFZ-KA09 12 18NA
22 MITSUBISHI ELECTRIC LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
I
RMULTI-ROOM MXZ-8 INVERTER HEAT PUMP
Model Name Outdoor Unit MXZ-BB4BNA Cooling 1 Rated Capacity
Non-ducted Rated Total Input Ducted
Maximum Capacity
Rated CapacityHeating at
Rated Total InputIndoor Unit 4JO F 2 Non-
ductedDucted Maximum Capacity
Rated Capacity Heating at
Rated Total InputlJO F 3 Non-ductedDucted Maximum Capacity
Power Supply Phase Cycle Voltage
Indoor - Outdoor Sl - S2 Voltage
Indoor - Outdoor S2 - S3
MCA
Recommended FuseBreaker Size
Fan Motor
Compressor
Airflow (CoolingHeating)
Refrigerant Control
Outdoor Unit Sound Pressure Level at Cooling 1
Sound Pressure Level at Heating 2
External Finish Color
Dimensions
Weight
Total Capacity 22-130
Indoor Unit ModelQuantity
Remote Controller Type
Type
Refrigerant Charge
Oil
Gas Side OD Refrigerant Pipe
Liquid Side OD
Height Difference (Max)
Maximum Distance between (Outdoor unit and farthest indoor unit)
Refrigerant Pipe Length Maximum Pipe Length -Branch box to Indoor Unit
Total Maximum line length between Branch Box and All Connected Indoor Units
Total Length (Max)
Connection Method IndoorOutdoor
Includes both branch boxes if there are two
Branch Boxes (At least one branch box required)
Btuh
W
Btuh
Btuh
W
Btuh
Btuh
W
Btuh
A
A
Type x Quantity
Motor Output (kW)
Model (Type)
Motor Output (kW)
CFM
dB(A)
dB(A)
W In
D In
H In
Lbs
Btuh
Lbs Oz
Type (fl oz)
In
In
Ft
Ft
Ft
Ft
Ft
4800048000
57806470
54000
5400054000
48205270
60000
3300034700
29503390
3660036550
1 Phase 60Hz 208 230V
AC 208-230V
DC12-24V
32
40
Propeller x 2
0086 + 0086
DC INVERTER-driven Scroll
29
3530
Linear Expansion Valve
54
55
Munsell No 3Y 78 11
37-716
13+1-3 16
53-3 16
278
12000 - 70200
600 - 24000 2-8
Associated with Indoor Unit Model
R410A
18 112
FV50S (73)
58
38
6698 4
230
49
197
377
FlaredFlared
Compatible with the MSZ-A MSZ-FO MSZ-FE MSZ-GE MFZ-KA SEZ-KD PLA and PEAD series indoor units
NOTES Test conditions are based on AHRI 210240 One indoor unit is turned off during low-speed testing under the new test conditions Systems actually exhibit higher energy efficiencies during normal operation
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F (35deg C) WB 75deg F (24deg C)
2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 4]0 F (8deg C) WB 43deg F (6deg C)
3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 17deg F (-8deg C) WB 15deg F(-9deg C)
4 66 applies to installations when the outdoor unit is installed below the indoor unit
Power factor equals 97 percent
Specifications are subject to change without notice
Note Maximum installed capacity is the maximum total of all connected indoor units NOT the maximum capacity produced
Only a single Lineset is needed from the outdoor unit to branch box
See page 25 for MXZ-B information on efficiency
Required Branch Boxes for MXZ-SB4BNA (Maximum of 2 branch boxes can be connected to one outdoor unit requires joint MSDD-50AR-E or MSDD-50BR-E)
s c d N o J ro Vl
0 ro n 3i n OJ d o J U)
PAC-AKA51 BC Branch Box
PAC-AKA31 BC Branch Box LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 23
MSZ WALL-MOUNTED INDOOR UNITS (FOR MXZ-8 OUTDOOR UNITS)
R
(MSZ-GE12NA MODEL SHOWN)
-000 IIIIIII 9000 9000 12000 12000 14000 17200
Heating at 4r Rated Capacity Btuh 7200 10900 10900 14400 13600 18000 21600
F2 Power Supply I Phase Cycle Voltage J -phase 60Hz 208 230V 3
Iindoor Outdoor S1 S2 AC 208 230V
Iindoor Outdoor S2 S3 DC12-24V Voltage
Iindoor Remote vomr Iller Wireless Type (Optional Wired vomroller DC 12V)
IMCA A 10 IFan Motor FLA 076
DRY 162-226shy145-170shy
162-226shy205-272shy 230-275shy
Airflow at Cooling (CFM)
145-170-237-321-399 339-381
237 -321shy381-410
335-420shy 339-420shy(Quiet-Lo-Med-Hishy 399 533 533 Super Hi or Lo-Med-
WET 144-202shy109-134shy
144-202shy170-237shy 194-240shy
Fan Hi-Powerful)1 (CFM)
109-134-201-286-364 307-343
201-286shy350-367
300-385shy 304-385shy364 498 498
Airflow at Heating 145-170shy 145-170shy 145-170shy 205-247shy 230-275shy
(Quiet-Lo-Med-Hi- WET 233-321shy 237-321shy
166-240shy237-321shy
166-240shy304-367shy 339-431shy
Super Hi or Lo-Medshy (CFM) 406 406
367 -381 406
399-420 463 512
Hi-Powerful) 2 Sound Pressure Level at Cooling
19-22-30shy 26-32-38shy 28-33-38shy(Quiet-Lo-Med-Hi-Super Hi or Loshy dB(A) 19-22-30-37 -43 22-31-39-42
37-45 22-33-43-45
44-49 44-49Med-Hi-Powerful) 1
Sound Pressure Level at Heating 19-22-30shy 26-30-35shy 28-33-38shy
(Quiet-Lo-Med-Hi-Super Hi or Loshy dB(A) 19-22-30-37 -43 22-31-40-42 37-43
22-23-43-44 40-46 43-48
Med-Hi-Powerful) 2
I External Finish Color Munsell No 10Y 92 02
IWln 31 middot716
Dimension Unit 10 In 9 18 10-18 9middot18 10-18 9-18
IH In 11-58
I Weight Unit ILbs 22 27 22 27 22 I Field Drainpipe ~D lin 58 Remote Con-
Type Wireless Remote (Optional Wired Controller) troller
ITvpe B41QA Refrigerant ~s$ideOD lin 38 Pipe I Liquid Side 00 In 14
Connection IndoorOutdoor FlaredFlared
Method
1~
II 18000 22500
21600 27600
388-469shy 38$-469shy628-738 628-738
347-420shy 347-420shy562-661 562-661
388-469shy 388-469shy628-738 628-738
34-41-49-53 34-41-49-53
32-41-49-52 32-41-49-52
43-516
9-38
12-1316 37
58 38
MXZ-2B20NA is also compatible with the MSZ-A and MSZ-FD series indoor units NOTES Test conditions are based on AHRI 210240
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F(6deg C) 3 Indoor units receive power from outdoor units through field-supplied wiring
Specifications are subject to change without notice LIMITED WARRANTY Seven-year warranty on compressor Five-year warranty on parts For data on specific indoor unit combinations see page 21
SEZ DUCTED INDOOR UNIT (FOR MXZ-8 OUTDOOR UNITS)
I
Notes 1 Cooling-Indoor DS 80deg F(267deg C) WS 67deg F(194deg C) Outdoor DS 95deg F (35deg C) WS 75deg F(239deg C)
2 Heating-Indoor DS 70deg F(211 deg C) WS 60deg F(156deg C) Outdoor DS 47deg F (83deg C) WS 43deg F(61 deg C)
3 External static pressure is factory set to 006 WGAdjustable via the
1---------t---+-----L-------------1~---__I PAR-21MAA
1--_____----__________+-____---L____----~_____________1 4 Indoor units receive power
jE~~~~-------------r----1-----~-~~~~~~~~-----___1 from outdoor units through fieldsupplied interconnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven-year warranty on compressor Five-year
1---------------------+---+------------------------1 warranty on parts
~--__I_~----------+-------~l----------I For data on specific indoor unit combinations see page 21 - 23
I--~------+~-----------~----------r_------------I
- Reference page 17 for SEZ static performance curves
24 MITSUBISHI ELECTRIC
25-30-35-40 26-31-36-41 35-38-42-46
25-30-35-40 28-31-36-41 35-38-42-47
MFZ FLOORLOW WALL INDOOR UNIT (FOR middotMXZ-8 OUTDOOR UNITS)
------shy
-==
Airflow at Heating (CFM) 177-198-219-332 184-201-219-335 261-275-297-434
Voltage
Fan
Airflow at Cooling (Lo-Med-Hi-Super Hi)1
169-205-251-314 251-279-325-394
163-197-241-303 170-207-252-309 241-269-313-379
(Lo-Med-Hi-Super Hi) 2
SLZ CEILING-RECESSED INDOOR UNIT (FOR MXZ-8 OUTDOOR UNITS) EFFICIENCY RATINGS
Voltage
Fan
Galvanized-steel SheetsMunsell 64Y 89 04
Refrigerant Pipe
Model Indoor Unit Type SEER HSPF
MXZ-2B20NA-1
Non-dueted 18 89
Dueted and Non-dueted 1675 87
Dueted 155 85
MXZ-2B20NA-1 ENERGY STAR amp
TAX CREDIT 2 x MSZ-GE09NA 18 89
MXZ-3B24NA
lJon-dueted 175 93
Dueted and Non-dueted 1625 89
Dueted 150 85
MXZ-3B24NA ENERGY STAR amp
TAX CREDIT
2 x MSZ-GE06NA 1 x MSZ-GE09NA
175 93
MXZ-3B24NA ENERGY STAR amp
TAX CREDIT
2 x MSZ-GE06NA 1 x MSZ-GE12NA
175 93
MXZ-3B30NA
Non-dueted 175 105
Dueted and Non-dueted 16 100
Dueted 145 95
MXZ-4B36NA
Non-dueted 18 93
Dueted and Non-dueted 16 5 92
Dueted 150 9 0
MXZ-BB4BNA
Non-dueted 15 87
Dueted and Non-dueted 14B B8
Dueted 147 89
Connection IndoorOutdoor FlaredFlared
Method
Notes 1 Cooling-Indoor DB 80deg F(267deg C) WB 67deg F(194deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(239deg C) 2 Heating-Indoor DB 70deg F(21 1 deg C) WB 60deg F(156deg C) Outdoor DB 47deg F(83deg C) WB 43deg F(61 deg C) 3 Indoor units receive power from outdoor units through field supplied interconnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 25
Notes 1 Cooling-Indoor DB 80deg F(267deg C) WB 67deg F (194deg C) Outdoor DB 95deg F (35deg C)WB 75deg F (239deg C)
2 Heating-Indoor DB 70deg F(211deg C) WB 60deg F (156deg C) Outdoor DB 47 F (83deg C) WB 43deg F (61 deg C)
3 Indoor units receive power from outdoor units through field supplied interco(lnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven -year warranty on compressor Five-year warranty on parts
Presently there is no 1 1 system with the MFZ indoor unit
s c
N o J ro Vl
C ro n ~ n OJ t o J V)
M-SERIES RATING CONDITIONS
INDOOR INTAKE AIR TEMPERATURE
OUTDOOR INTAKE AIR TEMPERATURE
COOLING
MAXIMUM
95degF DB 71 degF WB (MU SUZ MXZ-2B20-13B243B304B36) 90degF DB 73degF WB (MUZY-GE MUZ-FE MUzy-D)
115degF DB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B24 3B304B368B48)
MINIMUM 67degF DB 57degF WB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B201 3B243B304B36)
14degF DB (MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B24 3B304B36) 23degF DB (MXZ-8B48) 6rF DB (MU)
MAXIMUM 80degF DB 6rF WB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B243B304B36)
75degF DB 65degF WB (MUZY-GE MUZY-GA24 MUZ-FE SUZ MXZ-2B20-1 3B243B304B36) 70degF DB (MXZ-8B48)
HEATING
MINIMUM 70degF DB 60degFWB (MUZ-GE MUZ-GA24 MUZ-D MUZ-FE SUZ MXZ-2B20-1 3B243B304B36)
-13degF DB -15degFWB (MUZ-FE) -4degF DB -5degF WB (SUZ MUZ-GE) 5degF DB 4degF WB (MUZ-GA24 MXZ-8B48NA) 6degF DB 5degF WB (MXZ-2B20-1 3B24 3B304B36) 14degF DB 13degFWB (MUZ-D)
MU units operate at intake air temperature down to 10deg Fwith the addition of an ICM-326HM-1 low temperature control
REFRIGERANT TUBING SETS
OPTIONAL ACCESSORIES
REFRIGERANT LINE LENGTH FLARE FLARE _INDOOR UNIT OUTDOOR UNIT
MS-A09WA MU-A09WA 35 MS-A12WA
65 MU-A12WA 35
MSY-GE09NA 65
MUY-GE09NA 40
MSY-GE12NA
65
MUY-GE12NA 65 40
MSY-GE15NA MUY-GE15NA 40
MSY-GE18NA
65
MUY-GE18NA 100 50
MSZ-GE09NA MUZ-GE09NA 65 40
MSZ-GE12NA MUZ-GE12NA 40
MSZ-GE15NA
65
MUZ-GE15NA 40
MSZ-GE18NA
65
MUZ-GE18NA 100 50
MSY-GE24NA MUY-GE24NA 100 50
MSZ-GE24NA MUZ-GE24NA 100 50
MSY-D30NA MUY-D30NA 100 50
MSZ-D30NA MUZ-D30NA 50
MSY-D36NA
100
MUY-D36NA 50
MSZ-D36NA
100
MUZ-D36NA 100 50
MSZ-FE09NA MUZ-FE09NA 40
MSZ-FE12NA
65
MUZ-FE12NA 40
MSZ-GE06091215NA MSZ-FE0912NA
65
MXZ-2B20NA-1 164 4933MFZ-KA0912NA SEZ-KD09 1215NA
MSZ-GE0609 121518NA MSZ-FE091218N MFZ-KA09 1218NA MXZ-3B24NA 164 4933 SEZ -KD09 12 15 18NA SLZ-KA09 12 15NA
MSZ-GE0609 121518NA MSZ-GA24NA MSZ-FE091218NA
MXZ-3B30NA 4933230MFZ-KA091218NA SEZ -KD09 121518NA SLZ-KA09 12 15NA
MSZ-GE0609121518NA MSZ-GE24NA MSZ-FE09 12 18NA
MXZ-4B36NA 230 4933MFZ-KA091218NA SEZ -KD09121518NA SLZ-KA09 12 15NA
MSZ-GE0609 12 15 18NA MSZ-GE24NA MSZ-FE09 12 18NA
MXZ-8B48NA 6698377MFZ-KA091218NA SEZ-KD09121518NA SLZ-KA09 12 15NA
PART NUMBER I USE WITH I DESCRIPTION
Port Adapters and Connection Pipes MAC-A454JP-E MXZ-Series Adapter 38 X12
MAC-A455JP-E MXZ-Series Adapter 12 X38
MAC-A456JP-E MXZ-Series Adapter 12 X58
MSDD-50AR-E MXZ-Series Branch Box Tee Distribution Pipe - Flare Connection between two branch boxes
MSDD-50BR-E MXZ-Series Branch Box Tee Distribution Pipe - Braze Connection between two branch boxes
PAC-493PI MXZ-Series Adapter 14 X38
PAC-SG76RJ-E MXZ-Series Adapter 38 X58
OPTIONAL ACCESSORIES CONTINUED ON NEXT PAGE
49 amp 66 applies to installations in which the outdoor unit is installed below indoor unit26 MITSUBISHI ELECTRIC
OPTIONAL ACCESSORIES (CONTINUED)
PART NUMBER USE WITH DESCRIPTION Control Options and Accessories
M21 JKO 307 M-Series Indoor Units Remote temperature sensor for M-Series indoor units
MAC-397IF-E
MAC-399IF-E
PAC-YU25HT
PAR-21 MM-G
M-Series INVERTER Units
M-Series INVERTER Units
SEZ-KD Indoor Units
Use with P-Series SEZ and for wired M-Series Controller
MA and contact terminal interface - Required to use PAR-21 MM wired wall mount controller with M-Series Systems
CMCN M-NET control adapter I Interface for Mr Slim M-Series MSYZ SEZ I MFZ
External Fan I Heater control relay adapter
Deluxe MA remote controller (Requires MAC-397IF-E for use with M-Series - MSYZ MFZ)
SEZ Wireless remote controller for SEZ units (Requires signal receiver PAR-SA9FA-E)PAR-FL32MA
PAR-SA9CA-E SEZ Wireless signal receiver for SEZ
3-pole disconnect switch 30A 600V turns off power between indoor and outdoor units shyM-SeriesTAZ-MS303
mounts in 2 X 4 utility box and requires standard single gang switch platecover - Low Ambient
ICM-326HM-2 M-Series Non-INVERTER units Low ambient head pressure controller MUZ-GE091215 IVIUZ-FE0912 SUZ-KD091215
Drain pan heaterMAC-640BH-U outdoor unit
MAC-641 BH-U MUZ-GE18 SUZ-KD18 outdoor unit Drain pan heater Filters
MAC-1415FT-E Anti-allergy enzyme filter
MAC-2300FT
MSZlMSY-D3036
Anti -allergy enzyme filter
MAC-308FT
MSYMSZ-GA24
MSZ-FD912 I FE0912 Platinum deodorizing filter
MAC-408FT-E Anti-allergy enzyme filter
MAC-415FT-E
M-Series Indoor Unit - GE09GE12GE15GE18
MFZ-KA Air Cleaning FilterAnti-Aliergy Enzyme Filter
MAC-418FT Anti-allergy enzyme filter
Filter Boxes
FBL1-1
MSZ- FD912 I FE091 2
FB Series Filter Box for SEZ-KD09NA Optional filter box with MERV 8 filters
FB Series Filter Box for SEZ-KD1215NAFBL1-2 Optional filter box with MERV 8 filters
and PEA-A 12M
FBL1-3 FB Series Filter Box for SEZ-KD18NA Optional filter box with MERV 8 filters
Pumps
SI1730-230 MSYZ - 30000 Btuh or greater Sauermann mini condensation pump 230V
S13100-115 MS-Series - non-INVERTER Sauermann mini condensation pump 115V
S13100-230 Sauermann mini condensation pump 230VMSYZ - Less than 30000 Btuh
Miscellaneous BRP-1 Bottom Return Plate for SEZ-KD09NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-2 Bottom Return Plate for SEZ-KD12KD15-NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-3 Bottom Return Plate for SEZ-KD18NA Converts low profile ducted indoor unit from rear return to bottom return
BV12FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderreglnsulated - 12
BV14FSI Use with any Mr Sl im multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 14
BV38FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 38
BV58FSI Use with any IVIr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 58
Condensing unit wall mounting brackets (set of 2) - 440 lb capacity painted steel NOTE CWMB1 IVIU and PU outdoor units Installer is responsible to select and provide suitable hardware and materials to insure proper
mount of bracket to wall
DSD-400N M-Series DiamondBacktrade Platform Stands MUZ-GE18 I MUZ(y)-03036 I
MAC-811DS Drain socket assemblySUZ-KA18
MAC-851DS MUZ-FD0912 Drain socket
MAC-855SG M-Series Air outlet guide
MAC-856SG M-Series Air outlet guide - MXZ-3B24 I 3B30 I 4B36 NA
MAC-860DS MUZ-GE091215 I MUZ-FE0912 Drain socket
MAC-889SG M-Series Air outlet guide- MXZ-2B20NA
MAC-S99SG M-Series Air outlet guide
PAC-SG59SG-E IVIXZ-SB4SNA Air outlet guide (1 piece) I MXZ-SB48NA (Requires 2 pieces)
PAC-SG61 DS-E MXZ-8B4SNA Drain socket - connector
PAC-SG64DP-E MXZ-SB48NA Drain pan
RCMKP1CB lVI-Series Wireless Lockdown bracket for remote controller
lILTRILlTE1 All M-Series Condensing unit mounting pad 16 x 36 x 3
MITSUBISHI ELECTRIC 27
MXZ-8 Series Port Adapter chart Port Adapter Unit Port
Combinations Required Size
MXZ-2B20NA-1
2-zone combinations wi NA
A 38 x both units s12K 14
1-MAC-A454JP-E B 38 x
6+15 14
9+15 1-MAC-A454JP-E
MXZ-3B24NA
All rated 2-zone combina-NA
A 12 x tions 14
All rated 3-zone combina-NA
B 38 x tions 14
C 38 x 14
MXZ-3B30NA
2-zone combinations wi at NA
A 12 x least one unit s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
9 + 24 14
3-zone combinations wi 1-MAC-A455JP-E
all units s12K
All other rated 3-zone NA
comb
MXZ-4B36NA
2-zone combinations wi at NA
A 12 x least one un it s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
6 + 24 14
1-MAC-A456JP-E D 38 x
9 + 24 14
3-zone combinations wi at NA
least two units s12K
3-zone combinations wi 1-MAC-A454JP-E
two units15K
6+6+24 or 6+9+24 1-MAC-A456JP-E
9+9+24 1-MAC-A456JP-E
4-zone combinations wi at 1-MAC-A455JP-E
least three units s12K
6+6+15+15 1-MAC-A454JP-E
6+6+15+15 1-MAC-A454JP-E
Note When using the Pu-A24BA PCA-A24KA or PEAD-A24AA two port adapter will be needed 1-MAC-A456JP-E (12 x 58) A port or 1-PACshySG76RJ-E (38 x 58) B C and D ports and 1-PAC493PI (14 x 38)
28 JMITSUBISHI ELECTRIC
6+6+246+9+24 6+12+249+9+24 9+12+24 or 12+12+24
6+15+24 6+18+24 9+15+249+18+24 12+15+24 or 12+18+24
15+15+24 15+18+24 or 18+18+24
15+24+24 or 18+24+24
Combinations of 4 or more zones
1-PAC-SG76RJ-E
See notes for application below
2
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
See notes for application below
PORT A =38 gas x 14 liquid
PORT B =38 gas x 14 liquid
PORT C =38 gas x 14 liquid
PORT A =38 gas x 14 liquid
PORT B = 38 gas x 14 liquid
PORT C = 38 gas x 14 liquid
PORT D =38 gas x 14 liquid
PORT E =12 gas x 14 liquid
Notes for application bull Check the lineset sizes for your indoor selected models bull Select the branch box or boxes needed for your application bull Compare indoor unit lineset sizes as compared to branch
box sizes bull Connect 15K + indoor units to the larger port on the
(PAC-AKA51 BC) bull Adapt lineset size with appropriate port adapter from
above list bull When using the PU-A24BA or PEAD-A24AA two port
adapter will be needed 1-MAC-A456JP-E (12 x 58) or 1-PAC-SG76RJ-E (38 x 58) and 1-PAC493PI (14 x 38)
-fv
~ DIAMONDBACKtrade
~) BV-Series Ball Valves Model numbers
BV14FFSI BV38FFSI
LISTED 891N REFRIGERANT
BV12FFSI VALVE bull Engineered for Mini-split andBV58FFSI
Multi-split HVAC Units bull Size available 14 38 12 58
bull Full Port Designbull Fully factory assembled bull Furnace brazed and pressure tested bull 700 PSIG Rated bull Each ball valve is equipped with Schraderreg Valve
for refrigerant service bull R-410A Compatible bull Design working pressure 700 PSIG bull Temperature range bull Flare Connections
-40 0 F to +3250 F (-400 C to + 1490
C) bull Forged brass body and seal cap bull Teflonreg seals and gaskets (no synthetic a-rings) bull Seal cap design permits valve operation without
removal of seal cap bull Suitable for use with R-11 R-22 R-123 R-125
R-134A R-236FA R-4202A R-402B R-404A R-407C R-410A R-500 R-502 and R-507
bull One year limited materials and workmanship
Part Number SAE Flare
A B C 0 E F
BV14FFSI 14 619 260 180 122 142 110
BV38FFSI 38 630 267 180 122 142 110
BV12FFSI 12 651 267 180 122 142 110
BV58FFSI 58 664 267 180 128 142 110
Ball valves come With an insulation piece warranty on Ball Valves
~ DIAMONDBACKtrade
~) Platform Stands
Lift the Mitsubishi Electric Comfort Solution
outdoor unit to new heights with our Diamondback Platform Stands
bull Easy to install
bull Available for all sizes of Mr Slim outdoor units
bull Color matched to the outdoor units
Model Number DSD-400N
L 15-34 x W 3-14 x H 3-14
r
)MITSUBISHI ELECTRIC 29
~ DIAMONDBACKtrade LINESETS
~~
Twin-Tube Lineset Insulation Design
bull Balanced outside diameter for uniform coiluncoil position stability
bull Minimum 12 insulation thickness on both tubes Diamondback Advantages include the following features
bull Quick efficient and economical field installation using factory applied Twin Tube insulation and flare connections with flare nuts mounted
bull Correct lengths for reducing waste and time
bull Quality consistency and economy
bull All Diamondback Lineset tubing is tested in accordance with ASTM E243
Filter Boxes
FB Series filter boxes are available in compatible sizes for all Mr Slim horizontal ducted indoor units
FBL 1 filter boxes include 1 thick pleated MERV 8 filter(s) installed Filters are tested in accordance with ANSIASHRAE Standard 522 and Rated Class 2 under UL Standard 900
The cabinet is constructed of non-insulated 20 gauge G-60 galvanized
FBL1-1 FB Series Filter Box for SEZ-KD09NA
FBL1-2 FB Series Filter Box for SEZ-KD12KD15-NA
FBL1-3 FB Series Filter Box for SEZ-KD18NA
steel with foam gasket and provides an air-tight connection to indoor unit and access door Gasket material complies with UL 723 requirements
A screw-through cabinet design for secure attachment to indoor unit and return connection in rear is easily field-converted to bottom return
30 MITSUBISHI ELECTRIC
bull
bull
bull
bull
bull
bull
LINE-HIDE~ Put a professional finish on air-conditioning
installations with an easy-to-install modular
system that beautifies exteriors and
protects Linesets drainlines and wiring
Can be use it indoors too Meets UL94v-O for interior applications
Has snap-on covers and a full selection of couplings elbows T-joints caps and more for any application complex or simple
Offers high-quality PVC with UV inhibitors for outdoor service in all weather conditions
Can be painted with most house paints to match exterior decors
Is not just for HVAC Hide any exterior cabling piping or wiring
Available in four sizes 2-14 3 4 and 6 tubes
Download a brochure at wwwline-hidecom to find out more information
For more information on our CITY MULTI VRF product line visit our website at wwwmitsubishiprocom
_lIJrUlllln ~ ~IIII1 fInll l
~
l bull bull
JMITSUBISHI ELECTRIC 31
1shy(MS-A12WA MODEL SHOWN)
MS COOLING-ONLY
IJON-INVERTER
Model Name Indoor Unit
Outdoor Unit
MS-A09WA MS-A12WA
MU-A09WA MU-A12WA
Cooling 1
Rated Capacity Btuh 9500 12000
Capacity Range Btuh
Total Input W 870 1070
Energy Efficiency SEER 13
Moisture Removal Pintsh 27 32 Sensible Heat Factor 068 070
Power Supply Phase Cycle Voltage 1 Phase 60Hz 115V 2
Voltage Indoor - Outdoor L1-N AC 115V Indoor - Outdoor N-2 AC 115V Indoor - Remote Controller Wireless Type
Indoor Unit
MCA A 12
Fan Motor FLA 095
Airilow (Lo-Med-Hi Poweriul)
DRY (CFM) 183-261-335-367 222-286-406-446
WET (CFM) 162-233-300-328 198-254-363-399
Sound Pressure Level (Lo-Med-Hi)
dB(A) 26-32-40-42 33-38-45
External Finish Color Munsell No 1OY 9202
Dimension Unit
W In 30-1116
0 In 8-14
H In 11-34
Weight Unit Lbs 23
Field Drainpipe Size 00 In 58
Outdoor Unit
MCA A 14 16
MOCP (Time Delay) A 15 20
Fan Motor FLA 063 093
Compressor
Model (Type) Single Rotary
RLA 93 1082
LRA 47 56
Airilow CFM 1083 1327
Refrigerant Control Capillary Tube
Sound Pressure Level (Cooling) 1
dB(A) 47 52
External Finish Color Munsell No 3Y 7811
Dimensions
W In 31-12 33-716
0 In 11-14 11-716
H In 21-58 23-1316
Weight Lbs 78 96
Remote Controller Type Wireless Remote
Refrigerant
Type R410A Charge Lbs Oz 25 31
Oil Type (FI Oz) NE022 (108)
Refrigerant Pipe
Gas Side 00 In 38 12
Liquid Side 00 14
Height Difference (Max) Ft 35
Length (Max) 65
Connection Method IndoorOutdoor FlaredFlared
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling) - Indoor DB 800 F(270 e) WB 670 F(190 e) Outdoor DB 950 F(350 e) WB 750 F(240 e) 2 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice
LlIVIITED WARRANTY ISeven-year warranty on compressor Five-year warranty on parts
10 MITSUBISHI ELECTRIC
I
R ---I Vl
J(MSY-GE1 7NA MODEL SHOWN) OQ
MSY COOLI NG-ON LY (CO NT ) CD N o J CD
s Vl OJ J
Cooling 1 0shy
s Vl -lt Vl
~~~~~-=~------~~--------------------------~~~~----------------------------~ jVoltage
205-272-335shy145-170-237 -321-399
420-533 170-237 -300shy
385-498
26-32-38-44-49Indoor Unit
Outdoor Unit
194-240-304shy385-498
28-33-38-44-49
388-469-628-738
347-420-562-661
34-41-49-53
CD n 3-i n OJ 0389-639-848 o J350-576-763 V)
32-42-49
2 9 43Refrigerant
FV50S (040) NE022 (295)
Refrigerant Pipe
Refrigerant Pipe Length
Connection IndoorOutdoor FlaredFlared
Method
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling) - Indoor DB 80deg F(27deg e) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice
LIMITED WARRANTY ISeven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 11
~ (MSZ-FE12NA MODEL SHOWN)
MSZ HEAT PUMP TAX
CREDIT
Model Name
Cooling 1
Indoor Unit Outdoor Unit
Rated Capacity Btuh
MSZ-GE09NA MUZ-GE09NA
9000
MSZ-FE09NA HshyMUZ-FE09NA bull
9000
MSZ-GE12NA MUZ-GE12NA
12000
MSZ-FE12NA MUZ-FE12NA
12000
H-bull MSZ-G MUZ-G
14000
Capacity Range Btuh 3800-12200 2800-9000 3800-13600 2800-12000 3100-18200
Total Input W 660 (205-1200) 580 (160-650) 960 (205-1300) 930 (160-960) 1080 (160-2000)
Energy Efficiency SEER 21 26 205 23 21
Moisture Removal Pintsh 15 21 25 29 27
Sensible Heat Factor 082 076 074 073 080
Heating at 47deg F 2
Rated Capacity Btuh 10900 10900 14400 13600 18000
Capacity Range Btuh 4500-14100 3000-18000 5500-18100 3000-21000 4800-20900
Total Input W 760 (255-1200) 710 (150-2250) 1170 (340-1660) 950 (150-2250) 1600 (270-2010) HSPF (IV) BtuhlW 10 106 10
Heating at 17deg F3 Rated Capacity Btuh 6600 6700 8800 8300 11300 Rated Total Input W 700 650 900 800 1150 Maximum Capacity Btuh 8700 12500 11200 13600 15900
Heating at 5deg F Maximum Capacity Btuh 7061 10900 9194 12500 13022
Power Supply Phase Cycle Voltage 1-phase 60Hz 208 230V 4
Voltage
Indoor - Outdoor S1 - S2 AC 208 230V
Indoor - Outdoor S2 - S3 DC12-24V
Indoor - Remote Controller Wireless Type (Optional Wired Controller DC 12V)
Indoor Unit
MCA A 10
Fan Motor FLA 076
Airflow at Cooling (Lo-Med-Hi-Super HI-Powerful) 1
DRY (CFM) 145-170-237-321-399 162-226-339-381 145-170-237-321-399 162-226-381-410 205-272-335-420-533
WET (CFM) 109-134-201-286-364 144-202-307-343 109-134-201-286-364 144-202-350-367 170-237-300-385-498
Airflow at Heating (Lo-Med-Hi-Super HI-Powerful) 2
WET (CFM) 145-170-237-321-406 166-240-367-381 145-170-237-321-406 166-240-399-420 205-247 -304-367-463
Sound Pressure Level at Cooling (Lo-Med-Hi-Super HI-Powerful) 1
dB(A) 19-22-30-37-43 22-31-39-42 19-22-30-37-45 22-33-43-45 26-32-38-44-49
Sound Pressure Level at Heating (Lo-Med-Hi-Super HI-Powerful) 2
dB(A) 19-22-30-37-43 22-31-40-42 19-22-30-37-43 22-33-43-44 26-30-35-40-46
External Finish Color Munsell No 10Y 92 I 02
Dimension Unit
Wln 31-716 31-38 31-716 31-38 31-716
0 In 9-118 10-18 9-18 10-18 9-18
H In 11-58
Weight Unit Lbs 22 27 22 27 22
Field Drainpipe Size 00 In 58
Outdoor Unit
MCA A 12
MOCP A 15
Fan Motor FLA 050 056 050 056 050
Compressor
lVIodel (Type) DC INVERTER-driven DC INVERTER-driven Twin
Rotary DC INVERTER-driven DC IIWERTER-driven Twin Rotary
RLA 66 86 66 86 74
LRA 82 108 82 108 93
Airflow (CoolingHeating) CFM 11511225 1102 11187 12291172 1102 11187 12431229 Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(A) 46 48 49 48 49
Sound Pressure Level at Heating 2 dB(A) 50 49 51 49 51
External Finish Color Munsell No 3Y 78 11
Dimensions
Wln 31-12
0 In 11-114
H In 21-58
Weight Lbs 66 80 77 80
Remote Controller Type Wireless Remote (Optional Wired Controller)
Refrigerant
Type R410A
Charge Lbs Oz 112 29
Oil Type (fl oz) NE022 (108) NE022 (152)
Refrigerant Pipe Gas Side 00 In 38 12
Liquid Side 00 In 14 14
Refrigerant Pipe Length Height Difference (Max) Ft 40
Length (Max) Ft 65 I
Connection Method IndoorOutdoor FlaredFlared
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg e) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg e) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg e) Outdoor DB 47deg F(8deg e) WB 43deg F(6deg e) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg e) Outdoor DB 17deg F(-8deg e) WB 15deg F(-9deg e) 4 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice
12 +MITSUBISHI ELECTRIC LIMITED WARRANTY ISeven-year warranty on compressor Five-year warranty on parts
- shy(MSY(Z)-D30NA MODEL SHOWN)
Vl J
09 (I)
I
N o J (I)
s Vl N Vl
-0 (I) n 31 n OJ 0 o J V)
Model Name Indoor Unit MSZ-GE18NA MSZ-FE18N MSZ-GE24NA MSZ-D30NA MSZ-D36NA
Outdoor Unit MUZ-GE18NA MUZ-FE18rK MUZ-GE24NA MUZ-D30NA MUZ-D36NA Rated Capacity Btuh 17200 18000 22500 30700 33200
Capacity Range Btuh 3700-18700 8200-25200 8200-31400 9800-30700 9800-33200
Total Input W 1640 (240-2070) 1270 (570-2280) 1800 (570- 3580) 3850 (620-3850) 4360 (620-4360) Cooling 1
Energy Efficiency SEER 192 202 190 145
Moisture Removal Pintsh 46 27 27 99 11 3
Sensible Heat Factor 071 084 075 064 062
Rated Capacity Btuh 21600 21600 27600 32600 35200
Capacity Range Btuh 3500-25200 7500-29700 7500-36900 8700-34000 8700-36000 Heating at 47deg F 2
Total Input W 1900 (230-2680) 1540 (520-2240) 2340 (520- 3650) 3360 (520-3600) 3840 (520-4100)
HSPF (Region IV) BtuhIW 10 103 10 82
Rated Capacity Btuh 13400 11700 16000 19500 21800
Heating at 17deg F 3 Total Input W 1450 2180 3290 2400 2820
Maximum Capacity Btuh 17200 19300 24600 20800 22800 Heating at 5deg F
Maximum Capacity Btuh 13562 21 600 21160 16305 19090
Power Supply Phase Cycle Voltage 1 Phase 60Hz 208230V 4
Indoor - Outdoor S1-S2 AC 208 230V Voltage Indoor - Outdoor S2-S3 DC12-24
Indoor - Remote Controller Wireless Type (Optional Wired Controller DC12V) MCA A 10 Fan Motor FLA 076
DRY (CFM) 230-275-339-420-533 388-469-628-738 388-469-628-738 389-639-848 Airilow (Cool) (Lo-Med-Hi-Super HI-Poweriul) 1
WET (CFM) 194-240-304-385-498 347-420-562-661 347-420-562-661 350-576-763
Airilow (Heat) (Lo-Med-Hi-Super HI-Poweriul) 2 DRY (CFM) 230-275-339-431-512 388-469-628-738 388-469-628-738 445-639-848
Sound Pressure Level (Cooling) (Lo-Med-Hi-Super 28-33-38-44-49 34-41-49-53 34-41-49-53 32-42-49
HI-Poweriul) 1
Sound Pressure Level (Heating) (Lo-Med-Hi-Super dB(A)
Indoor Unit 28-33-38-43-48 32-41-49-52 32-41-49-52 34-42-49-49HI-Poweriul) 2
External Finish Color Munsell No 1 OY 9202
W In 31-716 43-516 46-116
Dimension Unit D In 9-18 9-38 11-58
H In 11-5 8 12-1316 14-38
Weight Unit Lbs 22 37 40
Field Drainpipe Size OD In 58
MCA A 14 171 21
MOCP A 15 20 25
Fan Motor FLA 093
Model (Type) DC INVERTER-driven Twin Rotary
Compressor RLA 100 129 16
LRA 125 161 20
Airilow CFM 1730 1659 17691 701 1941
Outdoor Unit Refrigerant Control Linear Ex~ansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(A) 54 55 56
Sound Pressure Level at Heating 2 dB(A) 56 55 57
External Finish Color Munsell No 3Y 7811
W In 33-116
Dimensions D In 13
H In 33-716 34-58 33-716
Weight Lbs 119 141
Remote Controller Type Wireless Remote (Optional Wired Controller)
Type R410A
Refrigerant Charge Lbs Oz 3 7 43 410
Oil Type (FI Oz) NE022 (152) FV50S (135) NE022 (29)
Gas Side OD 12 58In
Refrigerant Pipe Liquid Side OD 14 38
Height Difference (Max) 50
Length (Max) Ft
100 I Connection
Mpthon IndoorOutdoor Flared Flared
NOTESTest conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg C) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F (24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F(6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 17deg F(-8deg C) WB 15deg F(-9deg C) 4 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice LIMITED WARRANTY ISeven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 13
(SEZ-KD12NA MODEL SHOWN)
SEZ HEAT PUMP TAX
CREDIT
Model Name Indoor Unit SEZ-KD09NA4 SEZ-KD12NA4 SEZ-KD15NA4 SEZ-KD18NA4
Outdoor Unit SUZ-KA09NA SUZ-KA12NA SUZ-KA15NA SUZ-KA18NA Rated Capacity Btuh 8100 11500 14100 17200
Capacity Range Btuh 3800-10900 3800-13300 3800-17000 3800-19000
Cooling 1 Total Input W 670 920 1170 1380
Energy Efficiency SEER 15 16 155 175 Moisture Removal Pintsh 15 24 26 34 Sensible Heat Factor 080 076 080 079
Rated Capacity Btuh 10900 13600 18000 21600
Heating at 4YO F 2 Capacity Range Btuh 4800-14100 4800-16400 4800-21100 4800-24900
Total Input W 1020 1140 1500 1700 HSPF(lV) BtuhIW 100 Rated Capacity Btuh 6700 9000 11900 13100
Heating at 1 yo F 3 Rated Total Input W 810 920 1200 1350 Maximum Capacity Btuh 7300 9800 13700 15000
Power Supply Phase Cycle Voltage 1 Phase 60Hz 208 230V 4 Indoor - Outdoor S1 - S2 AC 208-230V
Voltage Indoor - Outdoor S2 - S3 DC 12-24V Indoor - Remote Controller See optional accessories chart (pg 26 and 27) MCA A 1 Fan Motor FLA 051 057 074
Airflow (Lo-Med-Hi) DRY (CFM) 194-247-317 247-317-388 353-441-529 423-529-635
WET (CFM) 174-222-285 222-285-349 317 -396-4 76 381-476-572 External Static Pressure 3 In wG 002-006-014-020 Sound Pressure Level dB(A) 23-26-30 23-28-33 30-34-37 30-34-38
Indoor Unit External Finish Galvanized-Steel Sheets
W In 31-18 39 46-78
Dimension Unit D In 27-916
H In 7-78
Weight Unit Lbs 42 50 54 62 Field Drainpipe Size 00 In 1-14
MCA A 12 14
MOCP A 15 Fan Motor FLA 050 093
Model DC Inverter DC Inverter Twin Rotary
I (Type)Compressor
RLA 66 74 10
LRA 82 93 125
Airflow (CoolingHeating) CFM 11511225 12291172 1 2431 229 17301659
Outdoor Unit Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(A) 46 49 54 Sound Pressure Level at Heating 2 dB(A) 50 51 56
External Finish Color Munsell No 3Y 7811
W In 31-12 33-16
Dimensions D In 11-14 13
H In 21-58 33-716
Weight Lbs 66 77 80 119 Remote Controller Type See optional accessories chart (pg 26 and 27)
Type R410A
Refrigerant Charge Lbs Oz 116 2 9
Type (fl Oil
oz) NE022 (108)
Refrigerant Pipe Gas Side OD In 38 Liquid Side 00 In 14
Refrigerant Pipe Height Difference (Max) Ft 40 Length Length (Max) Ft 65
Connection IndoorOutdoor FlaredFlared
Method
316
NE022 (152)
12
50
100
I
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg C) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F(8deg C) WB 43deg F(6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 17deg F(-8deg C) WB 15deg F(-9deg C) 4 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
14 MITSUBISHI ELECTRIC
SEZ STATIC PERFORMANCE CURVES (SEZ-KD12NA4 MODEL SHOWN)
SEZ-KD09NA4 SEZ-KD09NA4 (External static pressure O06[inwG]) 208230V 60Hz
[020] V L
5 [016
~l [0 12
]
SEZ-KD09NA4
~ ltij
~ [008
Jj
]
]
[004J ~
V V Middle
Low
V
19h
Rated point
1
o [141] [176J 1212) )247] [282J [318]
Airll ow rat e [CFM)
SEZ-KD12NA4 (External static pressure O06[inwG]) 208230V 60Hz
[020
5 [016
]
]
[353J
Limit
]
~ V
~ [ [0 12
u ltijJ[008
[004
]
_V ]~ Low
V
k-iddle
Rated POint
o [212) [247] [2 82] [318] [353] [388]
Airtlow rate [C FM]
SEZ-KD1SNA4 (External static pressure O06[inwGl) 208230V 60Hz
[424)
1020]
5 [016
~ ~ [012
~ ltij
~ [008
Jj
J
)
]
[004 ]
o
VV V [ Low
VV
vV High
Middle
I Rated point
[282] [318) [353] [388] [424] [459] [494] [530] [565J
Airllow rat e [CFM]
SEZ-KD18NA4 (External static pressure O06[inwG]) 208230V 60Hz
50 10 20]
] 40
5 [016
s 30 [ (012 )
ltij 20 ~ [008 )~Jj
10 [004]
V
Low
v Limit
rIV High
V [ Middle
~
1
Rated point
f318) [353) [388] [424] [459] [494] [530] [565] [600] [636] [671 )
Airllow rate [CFM]
(External static pressure O14[inwG]) 208230V 60Hz 80
[0 32
70 [028
5 60 [024
20 [0 08
10 [004
]
]
J
]
]
J
]V
]
U~it
V
k
High
~V Rated POI~1 V Middle Low
~
o [141] [1 76] 12121 )247J [282] [318]
Airtlow rate [CFM)
SEZ-KD12NA4 (External stat ic pressure O14[inwG]) 208230V 60Hz
[032]
[028J
5
[353]
J
~ [024
-~ [020] V-is
J V Il Hi9h Rated point
[016
~ ]
V V1 Middle
~ [012
[008]~
[004)
o [212)
[247)
SEZ-KD1SNA4
Low r
[282] [31 8) [353]
Airllow rale [CFM]
[388]
(External static pressure O14(inwG]) 208230V 60Hz
[032J
[424
]
2 V[028
5 [024]
V-i
] V High i [020
] K
Middle Rated point [0 16
g ]
~ -
QJj [0 12
J Low
[008
] I
~
[004
o [282J [318) [353J [388J [424) [459] [4 94] [530) [565)
Airt low rate [CFM]
SEZ-KD18NA4 (External statiC pressure O14(inwG]) 208230V 60Hz
1032
1028
~ 1024
-~ [0 20
is (0 16 ltij E ~ [012
(008
(004
o
I
]
]
)
]
)vlt ]
]
~ V
VV
Low
Limit
V
Ji9h
Middle l
Rated point
1 t
1
~ [318] [353] [388] [424] [459) [4 94] [530) [565) [600] [636] [671)
Airllow rate [CFM]
(External static pressure O20(inwG]) 208230V 60Hz
[032 ]
[028 J
5 [024
~ [020
is [016
1 [012Jj
[008
[004
J
]
]
] )
]
V Low
umz V High
~V
Rated point
Middle
1
[141] [176] [212) [247) [282) [318) [353J
Airtlow rat e [CFM]
SEZ-KD12NA4 (External static pressure O20(inwG]) 208230V 60H z
[032 ] LLimit
)
[0 28
5 ]
V
[024 -~ [020] V Rated point
Highis ~
) V
bull Middle
]~V I
[016
~ ~ [012
] Low
[008
]
[0 04
o [212) [247] [282] [318] [353] [388] [424]
Airllow rate [CFM]
SEZ-KD1SNA4 (External static pressure O20(inwG]) 208230V 60Hz
80 [032 ]
70 [0 28
~ [ O~~ -
ltij
E 30 ~ [0 12
20 [008
10 [004
o
)
J
]
]
JV
J
J
Limit V
LV High
V ~
K Rated point
Middle
VV 1gt
Low
I-
~ [282) [318) (353] (388) (424) 1459] [494] 15301 [565)
Airtlow rate [CFM]
SEZ-KD18NA4 (External static pressure O20[inwG]) 208230V 60Hz
[032
[028
~ [024sect
I [020
~ [016
~ Jj [0 12
[008
[004
o
]
)
]
]
]
~ )
]
]
1V
V 1
V
Low
1 limit
~~~ I ~~ High
~ R~ted pOini
Middle
1 1 -
[31 8) [353] [388] [424) [459] [494] [530] (565) [600] (636) [671J
Airllow rate [CFM)
Vl ~ ca (I)
I
N o ~ (I)
Vl m N Vl
-0 (I) n 3-i n QJ ~ o ~ tn
Note ESP 20S230V 60 Hz See manual for Static Performance Curve including 002 in WG
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts ~MITSUBISH[ ELECTRIC 15
SLZ HEAT PUMP (SLZ-KA12NA MODEL SHOWN)
Model Name Indoor Unit SLZ-KA09NA SLZ-KA12NA SLZ-KA15NA
Outdoor Unit SUZ-KA09NA SUZ-KA12NA SUZ-KA15NA Rated Capacity Btuh 8400 11100 15000
Capacity Range Btuh 3100-10900 3100-13300 3100-22200
Cooling 1 Total Input W 700 920 1460
Energy Efficiency SEER 15 154 16 Moisture Removal Pintsh 12 23 45 Sensible Heat Factor 080 076 080
Rated Capacity Btuh 10900 13 600 18000
Heating at 4r F 2 Capacity Range Btuh 3100-14100 3100-17100 3100-17100 Total Input W 930 1180 1950 HSPF (IV) BtuhIW 96 Rated Capacity Btuh 6200 8300 10200
Heating at 17deg F 3 Rated Total Input W 740 930 1310 Maximum Capacity Btuh 8300 10200 12000
Power Supply Phase Cycle Voltage 1 Phase 60Hz 208 230V 4 Indoor - Outdoor S1 - S2 AC 208-230V
Voltage Indoor - Outdoor S2 - S3 DC 12-24V
Indoor - Remote Controller See optional accessories chart (pg 26 and 27) MCA A 1 Fan Motor FLA 023 028 028
Airflow (Lo-Med-Hi) DRY (CFM) 280-320-350 280-320-390 280-320-390
WET (CFM) 250-290-320 250-290-350 250-290-350
Sound Pressure Level dB(Al 29-32-38 30-34-39 31-35-40
Indoor Unit External Finish Galvanized-Steel Sheets Grille Munsell 64Y 8904
W In 22-7 16 (25-58)
Dimension Unit (Grille) D In 22-716 (25-58
H In 8-316 (1316)
Weight Unit (Grille) Lbs 36 (7) Field Drainpipe Size 0 0 In 1-14 MCA A 12 MOCP A 15 Fan Motor FLA 050
Model (Type) DC INVERTER-driven DC INVERTER-driven
Compressor RLA 66
LRA 82
Airflow (CoolingHeating) CFM 11511225 1 229 1 172
Outdoor Unit Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(AJ 46 49 Sound Pressure Level at Heating 2 dB(AJ 50 51
External Finish Color Munsell No 3Y 781 1
W In 31 shy12
Dimensions 0 In 11-14
H In 21-58
Weight Lbs 66 77
~e R410A
Refrigerant Charge Lbs Oz 1 16
Oil Type (fl oz) NE022 108)
Refrigerant Pipe Gas Side 0 0 In 38 Liquid Side 00 In 14
Height Difference (Max) Ft 40 Refrigerant Pipe Length
Length (Max) Ft 65
Connection Method IndoorOutdoor FlaredFlared
29
Twin Rotary 74
93
12431 229
80
NE022 l152) 12
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg C) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F(8deg C) WB 43deg F(6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 17deg F(-8deg C) WB 15deg F(-9deg C) 4 Indoor units receive power from outdoor units through field-supplied interconnectedwiring Specifications are subject to change without notice
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
16 MITSUBISHI ELECTRIC
MHK1 WIRELESS REMOTE CONTROLLER KIT Exclusive for INVERTER-driven Mr Slimreg Systems VlWireless Technology a J
JMITSUBISHI ELECTRIC
Wireless Receiver
MHK1 Kit includes
09 mMRCH1 WIRELESS REMOTE CONTROLLER I Nbull Backlit easy-to-read display o
bull Dual setpoint control with system changeover J m
bull Enabled with RedLlNKTM reliability
bull Compatible with MCCH1 Vl Portable Central Controller m
N bull Installs Anywhere Vl
MFH1 WIRELESS RECEIVER N Vlbull Required for MRCH1 Wireless
CRemote Controller m bull Enabled with RedLiNK reliability n
31 n OJ o J en
SEZ and SLZ 11 systems with SUZ outdoor unit
Function Description
ONOFF OnOff operation for a single indoor unit
Operation Mode Cool I Drying I Auto I Heat I Fan only Available operation modes dependant on connected system
Temperature Setting Set temperature from 50degF - 8rF depending on operation mode and connected system
System Changeover Deadband Value 2-8degF
Schedule Operation 5-25-1-1
Fan Speed Setting HiMid-2Mid-1 IlowlAuto Available fan speed settings dependant on connected system
Air Flow Direction Setting Air flow angles 100deg - 80deg - 60deg - 40deg and oscilate Available air flow direction settings dependant on connected system
PermitProhibit Function Individual prohibit operations for each remote controller function (ONI OFF Set Temperature and Operation Mode)
Space Temperature Displays the measured space temperature
Error Indication Displays error code
Display Outside Temperature and Humidity
Requires optional MOS1 Outside Air Sensor
Dimensions - ryv x D x H) Remote Controller 5-316 x 1-12 x 3-916 Receiver 3-14 x 1-516 x 6-716
Operating Ambient Temperature Remote Controller 32 - 120degF Receiver -40 - 165degF
Operating Ambient Humidity Remote Controller 5 - 90 RH (non-condensing) Receiver 5 - 90 RH (non-condensing)
Power Supply 2 AA batteries
MRCH1 MIFH1 MRC1
Wireless Wall-Mounted Remote Controllers Wireless Receiver Cable
Accessories MCCH1 MOS1
Portable Central Controllers Outside Air Sensor
MITSUBISHI ELECTRIC 17
MULTIPLE ROOMS WITH INDIVIDUAL CONTROL FROM A SINGLE SYSTEM Enjoy ideal levels of comfort in the rooms you use most with our multi-room system Each room (zone) operates independently People in different rooms - the kitchen master bedroom or living room - can enjoy temperature settings that make each of them most comfortable
If you re looking for a complete comfort solution for several different rooms the MXZ multi-room system is the right choice The system is flexible enough to conform to a particular cooling and heating need and offers numerous different indoor unit combinations In addition up to eight indoor units can be connected to one outdoor unit Now with a SEZ horizontal ducted unit and a MFZ floorshystanding unit homeowners can enjoy an even greater range of zoning options provided by an MXZ system
An MXZ multi-room system is an excellent choice for supplementing capacity to a current system conditioning newly furnished spaces or new additions and replacing a system within a home Homeowners can also benefit from lower energy costs year-round while staying comfortable thanks to Mitsubishi Electrics energy-efficient technologies that are a part of every system that we make
To add to the level of energy efficiency the MXZ -2B20NA and MXZ -3B24NA systems qualify for both ENERGY STARreg and the federal tax credit (See details on page 21 for applicable indoor unit combinations)
At right a single level home with several system types represented (For illustrative purposes only)
MFZ Floor-Standing Indoor Units for MXZ Heat Pump Systems
Floor-standing indoor unit mounts three inches above the floor and has front panel access to the filter for ease of cleaning
The MFZ units provide energy-efficient solutions to provide personalized comfort for difficult areas that may be smaller or dont have usable space on the walls
MFZ units on MXZ systems include the following features bull Top and bottom discharge vanes bull Hot-start technology bull Quiet operation bull Wireless remote control (optional wall-mounted controller)
18 MITSUBISHI ELECTRIC
MSZ Wall-Mounted Indoor Units for MXZ Heat Pump Systems
Providing a wide range of cooling and heating capacities each wall-mounted indoor unit mounts high on a wall and connects to a branch box or the outdoor unit by a refrigerant line run via a 3 hole The MSZ units provide highly efficient solutions to cooling and heating needs and provide personalized comfort for the individual zones in which they are installed
MSZ units on MXZ systems include the following features bull Sleek flat panel design bull Hot-start technology bull Quiet operation bull i-seeM sensor technology (MSZ-FE0912NA models only) bull Enhanced filtration system (MSZ-FE0912NA models only) bull Wireless remote control (optional wired wall-mounted controller)
SLZ Ceiling-Recessed Indoor Units for MXZ Heat Pump Systems
The new SLZ-KA ceiling casette systems offer a wide air-flow pattern for better air distribution
offered to your customers Installation can be done in a hard ceiling (with a access panel for servicing) or placed into a 2x2 drop ceiling With a built-in drain lift mechanism for condensate
removal and a 4 ventilation air intake knockout option the SLZ is ready to handle a variety of installation needs
SLZ units on MXZ systems include the following features bull Wide air-flow pattern for better air distibution bull 4 ventillation air intake knockout bull Built-in condensate lift mechanism bull Wireless RedLlNKTM remote controller
SEZ Horizontal Ducted Indoor Units for MXZ Heat Pump Systems
SEZ ducted units can provide split air-conditioning system advantages with the added benefit of being concealed to provide virtually no visual footprint within the conditioned space other than a register and grille for the air to flow With the use of short run ductwork these units can provide comfort to a single room that needs air dispersed evenly throughout the space unusually shaped rooms and adjacent rooms
The SEZ unit on MXZ systems include the fOllvowin fatures _
g~e~~~~==Zl[bull Concealed design for short-run ductwork bull Quiet operation bull Built-in condensate lift mechanism
JMITSUBISHI ELECTRIC 19
s c t
I
N o J ro o ltro ~ ro ~
DIAMOND COMFORT MXZ MULTI-ZONE SYSTEMS MXZ-B Series multi-zone systems provide personalized comfort control and energy efficiency in up to eight rooms with only a single outdoor unit The MXZ-B Series system features include
bull Individual zone control bull Mix and match flexibility of indoor unit styles and combinations bull A wide range of indoor unit capacities that match the room size and requirements bull Flexible design options to tackle the most challenging multi-room installations bull Efficient systems including three systems [mxz series] that meet energy starltID and
federal tax credit requirements bull Simple quick and cost-effective installation keeps install costs down on new construction
and disruption to a minimum on renovations and refits
Efficiency and performance ratings depend on the number style and capacity of the indoor units installed with each Multi-Zone System
MXZ -2 B20 NA - 1 (2 1 ) MXZ -3 B24 NA (2 13 1) Ou tdoo r Unit Outdoor Uni t
MSZ-GE09NA Indoor Units
SEZ-KD12NA Indoor Unit
MSZ- GE06NA
~~~~li
(At least two indoor units MSZ-GE06NAIndoor Unit must be installed) Indoor Unit
(Two indoor units must be installed )
MXZ -3 B30 NA (2 1 3 1) Outdoor Unit
SEZ-KD12NA Indoor Unit
~~~i
(At least two indoor units MSZ-GE06NA must be installed)
Indoor Unit ~
MFZ- KD12NA Indoor Unit
MXZ-8B48NA (2 1-8 1) Outdoor Unit
(At least two indoor units
must be installed)
(At least two indoor units must be installed)
MFZ-KD09NA Indoor Units
MSZ-GE09NA Indoor Units
SEZ-KD12NA Indoor Unit
MSZ INDOOR UNIT
MSZ-FE18NA
PEAD HORIZONTAL -DUCTED INDOOR UNIT
PEAD-A24AA
MSZ INDOOR UNIT SEZ HORIZONTAL-DUCTED MSZ-FE18NA
INDOOR UNIT MFZ FLOOR-STANDING SEZ-KD18NA INDOOR UNIT
MFZ-KA12NA
20 AMITSUBISHI ELECTRIC
MULTI-ROOM MXZ-8 INVERTER HEAT PUMP R
Model Name Outdoor Unit MXZ-2B20NA-1 5 MXZ-3B24NA 6 MXZ-3B30NA MXZ-4B36NA 7
Indoor Unit
Cooling 1 Non-ductedl Ducted
Rated Capacity Btuh 1800020000 2200023600 28400127400 3540034400
Capacity Range Btuh 7800-20000 12600-25500 12600-28400 12600-36400
Total Input W 2190 (630-219QL 2460 (1000-2950) 3330 l1 000-3330) 3 940 (1 000-4020)
Heating at 4JO F 2 Non-ductedl Ducted
Rated Capacity Btuh 2200022000 2500024600 2860027600 3600034400
Capacity Range Btuh 8500-25500 11400-30600 11 400-36000 11400-43000
Total Input W 2620 (520-2620) 1900 (740-2600) 2220 (740-2820) 3100 (740-3940)
Heating at 1JO F 3 Non-ductedl Ducted
Rated Capacity Btuh 1250012500 1400014000 1600015100 2220020300
Rated Total Input W 13501430 13801570 21202 140 24302340
Maximum Capacity Btu h 1450014500 1880017000 1880018000 2460025400
Maximum Total Inl2ut W 15001590 21202230 21202140 33403450
Power Supply Phase Cycle Voltage 1-phase 60Hz 2081 230V 8
Voltage Indoor shy Outdoor S1 - S2 AC 2081 230V
Indoor shy Outdoor S2 - S3 DC12-24V
Outdoor Unit 4
MCA A 15 19
MOCP A 20
Fan Motor FLA 096 093
Compressor
Model (Type)
DC INVERTER-driven Twin Rotary
RLA 101 11 144
LRA 15
Airflow (CoolingHeating) CFM 14851 640 20681605 13651605 20682068
Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1
dB(A) 49 54 49 54
Sound Pressure Level at Heating 2
dB(A) 51 49 57
External Finish Color Munsell No 30Y 781 1
Dimensions
W In 33-116 35-716
D In 13 12-58
H In 27-1516 35-7116
Weight Lbs 130 150 153
Indoor Unit No of Units 2 23 23 234
Remote Controller Type Associated with the Indoor Unit
Refrigerant
Type R410A
Charge Lbs Oz 515 7 11 813
Oil Type (fl oz)
NE022 (237) NE022 (294)
Refrigerant Pipe Gas Side 00 In AB 38 A 12 BC 38 A 12 BCD 38
Liquid Side 00 In 14
Refrigerant Pipe Length Height Difference (Max) Ft 4933 9
Length (Max) Ft 164 (A+B) 230 (A+B+C) 230 (A+B+C+D)
Connection Method IndoorOutdoor FlaredlFlared
Compatible with the MSZ-A MSZ-GA MSZ-FD MSZ-FE MSZ-GE MFZ-KA and SEZ-KD series indoor units (PLA-18 amp PCA-24 on the MXZ-MXZ-3B PLA-24 amp PCA-24 on the MXZ-4B)
NOTES Test conditions are based on AHRI 210240 One indoor unit is turned off during low-speed testing under the new test conditions Systems actually exhibit higher energy efficiencies during normal operation
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F (35deg C) WB 75deg F (24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F (6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 600 F (160 C) Outdoor DB 17deg F (_80 C) WB 150 F (_90 C) 4 Refer to pages 12 and 13 for Indoor Unit specifications 5 Data from combination of two Indoor Units 9000 Btuh (non-ducted) or one 9000 Btuh and one 12000 Btuh (ducted) 6 Data from combination of two Indoor Units 6000 Btuh and one 9000 Btuh (non-ducted) or three 9000 Btuh (ducted) 7 Data from combination of four Indoor Units 9000 Btuh (non-ducted and ducted) 8 Indoor units receive power from outdoor units through field-supplied interconnected wiring 9 49 Applies to installations where the outdoor unit is installed below the indoor unit
Power factor equals 97 percent
Specifications are subject to change without notice
MULTI-ZONE ENERGY STAR AND TAX CREDIT SYSTEMS
Model Indoor Unit Combinations SEER HSPF
MXZ-2B20NA-1 2 x MSZ- GE09NA 18 8 9
MXZ- 3B24NA 2 x MSZ- GE06NA 1 x MSZshy GE09NA
17 5 9 3
MXZ- 3B24NA 2 x MSZ-GE06NA 1 x MSZ- GE12NA
17 5 93
For more details on all ENERGY STAR and tax credit systems go to wwwmitsubishicomfortcomtaxcredit
See page 25 for additional info on efficiency
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 21
MXZ-8B48NA THE ULTIMATE ZONING SOLUTION
The Mitsubishi Electric MXZ-S84SNA eight-zone unit As a member of the expanding MXZ-B Series of multi-zone systems the MXZ-8B outdoor unit incorporates branch boxes to connect up to eight indoor units MXZ- 8 B48 NA (2 1 - 8 1 )
Outd oor Uni t The INVERTER-driven compressor at the heart of the MXZ-8B -~-- shy
outdoor unit provides variable capacity control allowing the system to adjust to the specific demands of the interior space ~ as needed not the hard start and stop of a traditional system I[iDA Jinstalled in most US homes
The MXZ -8B48NA has only one port on the outdoor unit for two insulated refrigerant lines which run into the home or business to connect to a branch box or boxes From the branch box(es) gas and liquid refrigerant piping run to each of the indoor units The LEV in the branch box(es) controls the refrigerant flow as the load of each zone changes
Through the branch box(es) (the PAC-AKA31 BC three-port andor the PAC-AKA51 BC five-port) the system can connect from two indoor units up to eight indoor units depending on application requirements
The flexibility of the system doesnt stop there The MXZ-8B48NA has rated capacities of 48000 Btuh for cooling and 54000 Btuh for heating System operation however can range from a minimum 12000 Btuh to a maximum 54000 Btuh in cooling and a maximum of 60000 Btuh in heating This type of performance supports a large variety of applications
The MXZ-8B48NA allows for further flexibility because it supports a connected indoor unit capacity from 22 to 130 or 12000 Btuh to a maximum 70200 Btuh depending on diversity
Connectable Indoor Units General Features bull Four-ton outdoor unit can support up to
eight indoor units using branch boxes bull Wide variety of indoor unit styles
-=--_-=-----= - - J _ 1
including wall-mounted floor-standing MSZ-FE09 12 18NA MSZ-GE06 09 12 15 18 24NA ceiling-cassette ducted
bull Individual control up to eight (8) zones using wired or wireless controls
bull Advanced microprocessor control bull Auto restart following a power outage bull Self-check function offering SEZ-KD09 1215 18NA PEAD-A24AA
integrated diagnostics ~--- Jbull Limited warranty five years on parts and
defects and seven years on compressors
SLZ-KA09 1215NA MFZ-KA09 12 18NA
22 MITSUBISHI ELECTRIC LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
I
RMULTI-ROOM MXZ-8 INVERTER HEAT PUMP
Model Name Outdoor Unit MXZ-BB4BNA Cooling 1 Rated Capacity
Non-ducted Rated Total Input Ducted
Maximum Capacity
Rated CapacityHeating at
Rated Total InputIndoor Unit 4JO F 2 Non-
ductedDucted Maximum Capacity
Rated Capacity Heating at
Rated Total InputlJO F 3 Non-ductedDucted Maximum Capacity
Power Supply Phase Cycle Voltage
Indoor - Outdoor Sl - S2 Voltage
Indoor - Outdoor S2 - S3
MCA
Recommended FuseBreaker Size
Fan Motor
Compressor
Airflow (CoolingHeating)
Refrigerant Control
Outdoor Unit Sound Pressure Level at Cooling 1
Sound Pressure Level at Heating 2
External Finish Color
Dimensions
Weight
Total Capacity 22-130
Indoor Unit ModelQuantity
Remote Controller Type
Type
Refrigerant Charge
Oil
Gas Side OD Refrigerant Pipe
Liquid Side OD
Height Difference (Max)
Maximum Distance between (Outdoor unit and farthest indoor unit)
Refrigerant Pipe Length Maximum Pipe Length -Branch box to Indoor Unit
Total Maximum line length between Branch Box and All Connected Indoor Units
Total Length (Max)
Connection Method IndoorOutdoor
Includes both branch boxes if there are two
Branch Boxes (At least one branch box required)
Btuh
W
Btuh
Btuh
W
Btuh
Btuh
W
Btuh
A
A
Type x Quantity
Motor Output (kW)
Model (Type)
Motor Output (kW)
CFM
dB(A)
dB(A)
W In
D In
H In
Lbs
Btuh
Lbs Oz
Type (fl oz)
In
In
Ft
Ft
Ft
Ft
Ft
4800048000
57806470
54000
5400054000
48205270
60000
3300034700
29503390
3660036550
1 Phase 60Hz 208 230V
AC 208-230V
DC12-24V
32
40
Propeller x 2
0086 + 0086
DC INVERTER-driven Scroll
29
3530
Linear Expansion Valve
54
55
Munsell No 3Y 78 11
37-716
13+1-3 16
53-3 16
278
12000 - 70200
600 - 24000 2-8
Associated with Indoor Unit Model
R410A
18 112
FV50S (73)
58
38
6698 4
230
49
197
377
FlaredFlared
Compatible with the MSZ-A MSZ-FO MSZ-FE MSZ-GE MFZ-KA SEZ-KD PLA and PEAD series indoor units
NOTES Test conditions are based on AHRI 210240 One indoor unit is turned off during low-speed testing under the new test conditions Systems actually exhibit higher energy efficiencies during normal operation
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F (35deg C) WB 75deg F (24deg C)
2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 4]0 F (8deg C) WB 43deg F (6deg C)
3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 17deg F (-8deg C) WB 15deg F(-9deg C)
4 66 applies to installations when the outdoor unit is installed below the indoor unit
Power factor equals 97 percent
Specifications are subject to change without notice
Note Maximum installed capacity is the maximum total of all connected indoor units NOT the maximum capacity produced
Only a single Lineset is needed from the outdoor unit to branch box
See page 25 for MXZ-B information on efficiency
Required Branch Boxes for MXZ-SB4BNA (Maximum of 2 branch boxes can be connected to one outdoor unit requires joint MSDD-50AR-E or MSDD-50BR-E)
s c d N o J ro Vl
0 ro n 3i n OJ d o J U)
PAC-AKA51 BC Branch Box
PAC-AKA31 BC Branch Box LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 23
MSZ WALL-MOUNTED INDOOR UNITS (FOR MXZ-8 OUTDOOR UNITS)
R
(MSZ-GE12NA MODEL SHOWN)
-000 IIIIIII 9000 9000 12000 12000 14000 17200
Heating at 4r Rated Capacity Btuh 7200 10900 10900 14400 13600 18000 21600
F2 Power Supply I Phase Cycle Voltage J -phase 60Hz 208 230V 3
Iindoor Outdoor S1 S2 AC 208 230V
Iindoor Outdoor S2 S3 DC12-24V Voltage
Iindoor Remote vomr Iller Wireless Type (Optional Wired vomroller DC 12V)
IMCA A 10 IFan Motor FLA 076
DRY 162-226shy145-170shy
162-226shy205-272shy 230-275shy
Airflow at Cooling (CFM)
145-170-237-321-399 339-381
237 -321shy381-410
335-420shy 339-420shy(Quiet-Lo-Med-Hishy 399 533 533 Super Hi or Lo-Med-
WET 144-202shy109-134shy
144-202shy170-237shy 194-240shy
Fan Hi-Powerful)1 (CFM)
109-134-201-286-364 307-343
201-286shy350-367
300-385shy 304-385shy364 498 498
Airflow at Heating 145-170shy 145-170shy 145-170shy 205-247shy 230-275shy
(Quiet-Lo-Med-Hi- WET 233-321shy 237-321shy
166-240shy237-321shy
166-240shy304-367shy 339-431shy
Super Hi or Lo-Medshy (CFM) 406 406
367 -381 406
399-420 463 512
Hi-Powerful) 2 Sound Pressure Level at Cooling
19-22-30shy 26-32-38shy 28-33-38shy(Quiet-Lo-Med-Hi-Super Hi or Loshy dB(A) 19-22-30-37 -43 22-31-39-42
37-45 22-33-43-45
44-49 44-49Med-Hi-Powerful) 1
Sound Pressure Level at Heating 19-22-30shy 26-30-35shy 28-33-38shy
(Quiet-Lo-Med-Hi-Super Hi or Loshy dB(A) 19-22-30-37 -43 22-31-40-42 37-43
22-23-43-44 40-46 43-48
Med-Hi-Powerful) 2
I External Finish Color Munsell No 10Y 92 02
IWln 31 middot716
Dimension Unit 10 In 9 18 10-18 9middot18 10-18 9-18
IH In 11-58
I Weight Unit ILbs 22 27 22 27 22 I Field Drainpipe ~D lin 58 Remote Con-
Type Wireless Remote (Optional Wired Controller) troller
ITvpe B41QA Refrigerant ~s$ideOD lin 38 Pipe I Liquid Side 00 In 14
Connection IndoorOutdoor FlaredFlared
Method
1~
II 18000 22500
21600 27600
388-469shy 38$-469shy628-738 628-738
347-420shy 347-420shy562-661 562-661
388-469shy 388-469shy628-738 628-738
34-41-49-53 34-41-49-53
32-41-49-52 32-41-49-52
43-516
9-38
12-1316 37
58 38
MXZ-2B20NA is also compatible with the MSZ-A and MSZ-FD series indoor units NOTES Test conditions are based on AHRI 210240
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F(6deg C) 3 Indoor units receive power from outdoor units through field-supplied wiring
Specifications are subject to change without notice LIMITED WARRANTY Seven-year warranty on compressor Five-year warranty on parts For data on specific indoor unit combinations see page 21
SEZ DUCTED INDOOR UNIT (FOR MXZ-8 OUTDOOR UNITS)
I
Notes 1 Cooling-Indoor DS 80deg F(267deg C) WS 67deg F(194deg C) Outdoor DS 95deg F (35deg C) WS 75deg F(239deg C)
2 Heating-Indoor DS 70deg F(211 deg C) WS 60deg F(156deg C) Outdoor DS 47deg F (83deg C) WS 43deg F(61 deg C)
3 External static pressure is factory set to 006 WGAdjustable via the
1---------t---+-----L-------------1~---__I PAR-21MAA
1--_____----__________+-____---L____----~_____________1 4 Indoor units receive power
jE~~~~-------------r----1-----~-~~~~~~~~-----___1 from outdoor units through fieldsupplied interconnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven-year warranty on compressor Five-year
1---------------------+---+------------------------1 warranty on parts
~--__I_~----------+-------~l----------I For data on specific indoor unit combinations see page 21 - 23
I--~------+~-----------~----------r_------------I
- Reference page 17 for SEZ static performance curves
24 MITSUBISHI ELECTRIC
25-30-35-40 26-31-36-41 35-38-42-46
25-30-35-40 28-31-36-41 35-38-42-47
MFZ FLOORLOW WALL INDOOR UNIT (FOR middotMXZ-8 OUTDOOR UNITS)
------shy
-==
Airflow at Heating (CFM) 177-198-219-332 184-201-219-335 261-275-297-434
Voltage
Fan
Airflow at Cooling (Lo-Med-Hi-Super Hi)1
169-205-251-314 251-279-325-394
163-197-241-303 170-207-252-309 241-269-313-379
(Lo-Med-Hi-Super Hi) 2
SLZ CEILING-RECESSED INDOOR UNIT (FOR MXZ-8 OUTDOOR UNITS) EFFICIENCY RATINGS
Voltage
Fan
Galvanized-steel SheetsMunsell 64Y 89 04
Refrigerant Pipe
Model Indoor Unit Type SEER HSPF
MXZ-2B20NA-1
Non-dueted 18 89
Dueted and Non-dueted 1675 87
Dueted 155 85
MXZ-2B20NA-1 ENERGY STAR amp
TAX CREDIT 2 x MSZ-GE09NA 18 89
MXZ-3B24NA
lJon-dueted 175 93
Dueted and Non-dueted 1625 89
Dueted 150 85
MXZ-3B24NA ENERGY STAR amp
TAX CREDIT
2 x MSZ-GE06NA 1 x MSZ-GE09NA
175 93
MXZ-3B24NA ENERGY STAR amp
TAX CREDIT
2 x MSZ-GE06NA 1 x MSZ-GE12NA
175 93
MXZ-3B30NA
Non-dueted 175 105
Dueted and Non-dueted 16 100
Dueted 145 95
MXZ-4B36NA
Non-dueted 18 93
Dueted and Non-dueted 16 5 92
Dueted 150 9 0
MXZ-BB4BNA
Non-dueted 15 87
Dueted and Non-dueted 14B B8
Dueted 147 89
Connection IndoorOutdoor FlaredFlared
Method
Notes 1 Cooling-Indoor DB 80deg F(267deg C) WB 67deg F(194deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(239deg C) 2 Heating-Indoor DB 70deg F(21 1 deg C) WB 60deg F(156deg C) Outdoor DB 47deg F(83deg C) WB 43deg F(61 deg C) 3 Indoor units receive power from outdoor units through field supplied interconnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 25
Notes 1 Cooling-Indoor DB 80deg F(267deg C) WB 67deg F (194deg C) Outdoor DB 95deg F (35deg C)WB 75deg F (239deg C)
2 Heating-Indoor DB 70deg F(211deg C) WB 60deg F (156deg C) Outdoor DB 47 F (83deg C) WB 43deg F (61 deg C)
3 Indoor units receive power from outdoor units through field supplied interco(lnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven -year warranty on compressor Five-year warranty on parts
Presently there is no 1 1 system with the MFZ indoor unit
s c
N o J ro Vl
C ro n ~ n OJ t o J V)
M-SERIES RATING CONDITIONS
INDOOR INTAKE AIR TEMPERATURE
OUTDOOR INTAKE AIR TEMPERATURE
COOLING
MAXIMUM
95degF DB 71 degF WB (MU SUZ MXZ-2B20-13B243B304B36) 90degF DB 73degF WB (MUZY-GE MUZ-FE MUzy-D)
115degF DB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B24 3B304B368B48)
MINIMUM 67degF DB 57degF WB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B201 3B243B304B36)
14degF DB (MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B24 3B304B36) 23degF DB (MXZ-8B48) 6rF DB (MU)
MAXIMUM 80degF DB 6rF WB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B243B304B36)
75degF DB 65degF WB (MUZY-GE MUZY-GA24 MUZ-FE SUZ MXZ-2B20-1 3B243B304B36) 70degF DB (MXZ-8B48)
HEATING
MINIMUM 70degF DB 60degFWB (MUZ-GE MUZ-GA24 MUZ-D MUZ-FE SUZ MXZ-2B20-1 3B243B304B36)
-13degF DB -15degFWB (MUZ-FE) -4degF DB -5degF WB (SUZ MUZ-GE) 5degF DB 4degF WB (MUZ-GA24 MXZ-8B48NA) 6degF DB 5degF WB (MXZ-2B20-1 3B24 3B304B36) 14degF DB 13degFWB (MUZ-D)
MU units operate at intake air temperature down to 10deg Fwith the addition of an ICM-326HM-1 low temperature control
REFRIGERANT TUBING SETS
OPTIONAL ACCESSORIES
REFRIGERANT LINE LENGTH FLARE FLARE _INDOOR UNIT OUTDOOR UNIT
MS-A09WA MU-A09WA 35 MS-A12WA
65 MU-A12WA 35
MSY-GE09NA 65
MUY-GE09NA 40
MSY-GE12NA
65
MUY-GE12NA 65 40
MSY-GE15NA MUY-GE15NA 40
MSY-GE18NA
65
MUY-GE18NA 100 50
MSZ-GE09NA MUZ-GE09NA 65 40
MSZ-GE12NA MUZ-GE12NA 40
MSZ-GE15NA
65
MUZ-GE15NA 40
MSZ-GE18NA
65
MUZ-GE18NA 100 50
MSY-GE24NA MUY-GE24NA 100 50
MSZ-GE24NA MUZ-GE24NA 100 50
MSY-D30NA MUY-D30NA 100 50
MSZ-D30NA MUZ-D30NA 50
MSY-D36NA
100
MUY-D36NA 50
MSZ-D36NA
100
MUZ-D36NA 100 50
MSZ-FE09NA MUZ-FE09NA 40
MSZ-FE12NA
65
MUZ-FE12NA 40
MSZ-GE06091215NA MSZ-FE0912NA
65
MXZ-2B20NA-1 164 4933MFZ-KA0912NA SEZ-KD09 1215NA
MSZ-GE0609 121518NA MSZ-FE091218N MFZ-KA09 1218NA MXZ-3B24NA 164 4933 SEZ -KD09 12 15 18NA SLZ-KA09 12 15NA
MSZ-GE0609 121518NA MSZ-GA24NA MSZ-FE091218NA
MXZ-3B30NA 4933230MFZ-KA091218NA SEZ -KD09 121518NA SLZ-KA09 12 15NA
MSZ-GE0609121518NA MSZ-GE24NA MSZ-FE09 12 18NA
MXZ-4B36NA 230 4933MFZ-KA091218NA SEZ -KD09121518NA SLZ-KA09 12 15NA
MSZ-GE0609 12 15 18NA MSZ-GE24NA MSZ-FE09 12 18NA
MXZ-8B48NA 6698377MFZ-KA091218NA SEZ-KD09121518NA SLZ-KA09 12 15NA
PART NUMBER I USE WITH I DESCRIPTION
Port Adapters and Connection Pipes MAC-A454JP-E MXZ-Series Adapter 38 X12
MAC-A455JP-E MXZ-Series Adapter 12 X38
MAC-A456JP-E MXZ-Series Adapter 12 X58
MSDD-50AR-E MXZ-Series Branch Box Tee Distribution Pipe - Flare Connection between two branch boxes
MSDD-50BR-E MXZ-Series Branch Box Tee Distribution Pipe - Braze Connection between two branch boxes
PAC-493PI MXZ-Series Adapter 14 X38
PAC-SG76RJ-E MXZ-Series Adapter 38 X58
OPTIONAL ACCESSORIES CONTINUED ON NEXT PAGE
49 amp 66 applies to installations in which the outdoor unit is installed below indoor unit26 MITSUBISHI ELECTRIC
OPTIONAL ACCESSORIES (CONTINUED)
PART NUMBER USE WITH DESCRIPTION Control Options and Accessories
M21 JKO 307 M-Series Indoor Units Remote temperature sensor for M-Series indoor units
MAC-397IF-E
MAC-399IF-E
PAC-YU25HT
PAR-21 MM-G
M-Series INVERTER Units
M-Series INVERTER Units
SEZ-KD Indoor Units
Use with P-Series SEZ and for wired M-Series Controller
MA and contact terminal interface - Required to use PAR-21 MM wired wall mount controller with M-Series Systems
CMCN M-NET control adapter I Interface for Mr Slim M-Series MSYZ SEZ I MFZ
External Fan I Heater control relay adapter
Deluxe MA remote controller (Requires MAC-397IF-E for use with M-Series - MSYZ MFZ)
SEZ Wireless remote controller for SEZ units (Requires signal receiver PAR-SA9FA-E)PAR-FL32MA
PAR-SA9CA-E SEZ Wireless signal receiver for SEZ
3-pole disconnect switch 30A 600V turns off power between indoor and outdoor units shyM-SeriesTAZ-MS303
mounts in 2 X 4 utility box and requires standard single gang switch platecover - Low Ambient
ICM-326HM-2 M-Series Non-INVERTER units Low ambient head pressure controller MUZ-GE091215 IVIUZ-FE0912 SUZ-KD091215
Drain pan heaterMAC-640BH-U outdoor unit
MAC-641 BH-U MUZ-GE18 SUZ-KD18 outdoor unit Drain pan heater Filters
MAC-1415FT-E Anti-allergy enzyme filter
MAC-2300FT
MSZlMSY-D3036
Anti -allergy enzyme filter
MAC-308FT
MSYMSZ-GA24
MSZ-FD912 I FE0912 Platinum deodorizing filter
MAC-408FT-E Anti-allergy enzyme filter
MAC-415FT-E
M-Series Indoor Unit - GE09GE12GE15GE18
MFZ-KA Air Cleaning FilterAnti-Aliergy Enzyme Filter
MAC-418FT Anti-allergy enzyme filter
Filter Boxes
FBL1-1
MSZ- FD912 I FE091 2
FB Series Filter Box for SEZ-KD09NA Optional filter box with MERV 8 filters
FB Series Filter Box for SEZ-KD1215NAFBL1-2 Optional filter box with MERV 8 filters
and PEA-A 12M
FBL1-3 FB Series Filter Box for SEZ-KD18NA Optional filter box with MERV 8 filters
Pumps
SI1730-230 MSYZ - 30000 Btuh or greater Sauermann mini condensation pump 230V
S13100-115 MS-Series - non-INVERTER Sauermann mini condensation pump 115V
S13100-230 Sauermann mini condensation pump 230VMSYZ - Less than 30000 Btuh
Miscellaneous BRP-1 Bottom Return Plate for SEZ-KD09NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-2 Bottom Return Plate for SEZ-KD12KD15-NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-3 Bottom Return Plate for SEZ-KD18NA Converts low profile ducted indoor unit from rear return to bottom return
BV12FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderreglnsulated - 12
BV14FSI Use with any Mr Sl im multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 14
BV38FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 38
BV58FSI Use with any IVIr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 58
Condensing unit wall mounting brackets (set of 2) - 440 lb capacity painted steel NOTE CWMB1 IVIU and PU outdoor units Installer is responsible to select and provide suitable hardware and materials to insure proper
mount of bracket to wall
DSD-400N M-Series DiamondBacktrade Platform Stands MUZ-GE18 I MUZ(y)-03036 I
MAC-811DS Drain socket assemblySUZ-KA18
MAC-851DS MUZ-FD0912 Drain socket
MAC-855SG M-Series Air outlet guide
MAC-856SG M-Series Air outlet guide - MXZ-3B24 I 3B30 I 4B36 NA
MAC-860DS MUZ-GE091215 I MUZ-FE0912 Drain socket
MAC-889SG M-Series Air outlet guide- MXZ-2B20NA
MAC-S99SG M-Series Air outlet guide
PAC-SG59SG-E IVIXZ-SB4SNA Air outlet guide (1 piece) I MXZ-SB48NA (Requires 2 pieces)
PAC-SG61 DS-E MXZ-8B4SNA Drain socket - connector
PAC-SG64DP-E MXZ-SB48NA Drain pan
RCMKP1CB lVI-Series Wireless Lockdown bracket for remote controller
lILTRILlTE1 All M-Series Condensing unit mounting pad 16 x 36 x 3
MITSUBISHI ELECTRIC 27
MXZ-8 Series Port Adapter chart Port Adapter Unit Port
Combinations Required Size
MXZ-2B20NA-1
2-zone combinations wi NA
A 38 x both units s12K 14
1-MAC-A454JP-E B 38 x
6+15 14
9+15 1-MAC-A454JP-E
MXZ-3B24NA
All rated 2-zone combina-NA
A 12 x tions 14
All rated 3-zone combina-NA
B 38 x tions 14
C 38 x 14
MXZ-3B30NA
2-zone combinations wi at NA
A 12 x least one unit s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
9 + 24 14
3-zone combinations wi 1-MAC-A455JP-E
all units s12K
All other rated 3-zone NA
comb
MXZ-4B36NA
2-zone combinations wi at NA
A 12 x least one un it s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
6 + 24 14
1-MAC-A456JP-E D 38 x
9 + 24 14
3-zone combinations wi at NA
least two units s12K
3-zone combinations wi 1-MAC-A454JP-E
two units15K
6+6+24 or 6+9+24 1-MAC-A456JP-E
9+9+24 1-MAC-A456JP-E
4-zone combinations wi at 1-MAC-A455JP-E
least three units s12K
6+6+15+15 1-MAC-A454JP-E
6+6+15+15 1-MAC-A454JP-E
Note When using the Pu-A24BA PCA-A24KA or PEAD-A24AA two port adapter will be needed 1-MAC-A456JP-E (12 x 58) A port or 1-PACshySG76RJ-E (38 x 58) B C and D ports and 1-PAC493PI (14 x 38)
28 JMITSUBISHI ELECTRIC
6+6+246+9+24 6+12+249+9+24 9+12+24 or 12+12+24
6+15+24 6+18+24 9+15+249+18+24 12+15+24 or 12+18+24
15+15+24 15+18+24 or 18+18+24
15+24+24 or 18+24+24
Combinations of 4 or more zones
1-PAC-SG76RJ-E
See notes for application below
2
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
See notes for application below
PORT A =38 gas x 14 liquid
PORT B =38 gas x 14 liquid
PORT C =38 gas x 14 liquid
PORT A =38 gas x 14 liquid
PORT B = 38 gas x 14 liquid
PORT C = 38 gas x 14 liquid
PORT D =38 gas x 14 liquid
PORT E =12 gas x 14 liquid
Notes for application bull Check the lineset sizes for your indoor selected models bull Select the branch box or boxes needed for your application bull Compare indoor unit lineset sizes as compared to branch
box sizes bull Connect 15K + indoor units to the larger port on the
(PAC-AKA51 BC) bull Adapt lineset size with appropriate port adapter from
above list bull When using the PU-A24BA or PEAD-A24AA two port
adapter will be needed 1-MAC-A456JP-E (12 x 58) or 1-PAC-SG76RJ-E (38 x 58) and 1-PAC493PI (14 x 38)
-fv
~ DIAMONDBACKtrade
~) BV-Series Ball Valves Model numbers
BV14FFSI BV38FFSI
LISTED 891N REFRIGERANT
BV12FFSI VALVE bull Engineered for Mini-split andBV58FFSI
Multi-split HVAC Units bull Size available 14 38 12 58
bull Full Port Designbull Fully factory assembled bull Furnace brazed and pressure tested bull 700 PSIG Rated bull Each ball valve is equipped with Schraderreg Valve
for refrigerant service bull R-410A Compatible bull Design working pressure 700 PSIG bull Temperature range bull Flare Connections
-40 0 F to +3250 F (-400 C to + 1490
C) bull Forged brass body and seal cap bull Teflonreg seals and gaskets (no synthetic a-rings) bull Seal cap design permits valve operation without
removal of seal cap bull Suitable for use with R-11 R-22 R-123 R-125
R-134A R-236FA R-4202A R-402B R-404A R-407C R-410A R-500 R-502 and R-507
bull One year limited materials and workmanship
Part Number SAE Flare
A B C 0 E F
BV14FFSI 14 619 260 180 122 142 110
BV38FFSI 38 630 267 180 122 142 110
BV12FFSI 12 651 267 180 122 142 110
BV58FFSI 58 664 267 180 128 142 110
Ball valves come With an insulation piece warranty on Ball Valves
~ DIAMONDBACKtrade
~) Platform Stands
Lift the Mitsubishi Electric Comfort Solution
outdoor unit to new heights with our Diamondback Platform Stands
bull Easy to install
bull Available for all sizes of Mr Slim outdoor units
bull Color matched to the outdoor units
Model Number DSD-400N
L 15-34 x W 3-14 x H 3-14
r
)MITSUBISHI ELECTRIC 29
~ DIAMONDBACKtrade LINESETS
~~
Twin-Tube Lineset Insulation Design
bull Balanced outside diameter for uniform coiluncoil position stability
bull Minimum 12 insulation thickness on both tubes Diamondback Advantages include the following features
bull Quick efficient and economical field installation using factory applied Twin Tube insulation and flare connections with flare nuts mounted
bull Correct lengths for reducing waste and time
bull Quality consistency and economy
bull All Diamondback Lineset tubing is tested in accordance with ASTM E243
Filter Boxes
FB Series filter boxes are available in compatible sizes for all Mr Slim horizontal ducted indoor units
FBL 1 filter boxes include 1 thick pleated MERV 8 filter(s) installed Filters are tested in accordance with ANSIASHRAE Standard 522 and Rated Class 2 under UL Standard 900
The cabinet is constructed of non-insulated 20 gauge G-60 galvanized
FBL1-1 FB Series Filter Box for SEZ-KD09NA
FBL1-2 FB Series Filter Box for SEZ-KD12KD15-NA
FBL1-3 FB Series Filter Box for SEZ-KD18NA
steel with foam gasket and provides an air-tight connection to indoor unit and access door Gasket material complies with UL 723 requirements
A screw-through cabinet design for secure attachment to indoor unit and return connection in rear is easily field-converted to bottom return
30 MITSUBISHI ELECTRIC
bull
bull
bull
bull
bull
bull
LINE-HIDE~ Put a professional finish on air-conditioning
installations with an easy-to-install modular
system that beautifies exteriors and
protects Linesets drainlines and wiring
Can be use it indoors too Meets UL94v-O for interior applications
Has snap-on covers and a full selection of couplings elbows T-joints caps and more for any application complex or simple
Offers high-quality PVC with UV inhibitors for outdoor service in all weather conditions
Can be painted with most house paints to match exterior decors
Is not just for HVAC Hide any exterior cabling piping or wiring
Available in four sizes 2-14 3 4 and 6 tubes
Download a brochure at wwwline-hidecom to find out more information
For more information on our CITY MULTI VRF product line visit our website at wwwmitsubishiprocom
_lIJrUlllln ~ ~IIII1 fInll l
~
l bull bull
JMITSUBISHI ELECTRIC 31
I
R ---I Vl
J(MSY-GE1 7NA MODEL SHOWN) OQ
MSY COOLI NG-ON LY (CO NT ) CD N o J CD
s Vl OJ J
Cooling 1 0shy
s Vl -lt Vl
~~~~~-=~------~~--------------------------~~~~----------------------------~ jVoltage
205-272-335shy145-170-237 -321-399
420-533 170-237 -300shy
385-498
26-32-38-44-49Indoor Unit
Outdoor Unit
194-240-304shy385-498
28-33-38-44-49
388-469-628-738
347-420-562-661
34-41-49-53
CD n 3-i n OJ 0389-639-848 o J350-576-763 V)
32-42-49
2 9 43Refrigerant
FV50S (040) NE022 (295)
Refrigerant Pipe
Refrigerant Pipe Length
Connection IndoorOutdoor FlaredFlared
Method
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling) - Indoor DB 80deg F(27deg e) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice
LIMITED WARRANTY ISeven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 11
~ (MSZ-FE12NA MODEL SHOWN)
MSZ HEAT PUMP TAX
CREDIT
Model Name
Cooling 1
Indoor Unit Outdoor Unit
Rated Capacity Btuh
MSZ-GE09NA MUZ-GE09NA
9000
MSZ-FE09NA HshyMUZ-FE09NA bull
9000
MSZ-GE12NA MUZ-GE12NA
12000
MSZ-FE12NA MUZ-FE12NA
12000
H-bull MSZ-G MUZ-G
14000
Capacity Range Btuh 3800-12200 2800-9000 3800-13600 2800-12000 3100-18200
Total Input W 660 (205-1200) 580 (160-650) 960 (205-1300) 930 (160-960) 1080 (160-2000)
Energy Efficiency SEER 21 26 205 23 21
Moisture Removal Pintsh 15 21 25 29 27
Sensible Heat Factor 082 076 074 073 080
Heating at 47deg F 2
Rated Capacity Btuh 10900 10900 14400 13600 18000
Capacity Range Btuh 4500-14100 3000-18000 5500-18100 3000-21000 4800-20900
Total Input W 760 (255-1200) 710 (150-2250) 1170 (340-1660) 950 (150-2250) 1600 (270-2010) HSPF (IV) BtuhlW 10 106 10
Heating at 17deg F3 Rated Capacity Btuh 6600 6700 8800 8300 11300 Rated Total Input W 700 650 900 800 1150 Maximum Capacity Btuh 8700 12500 11200 13600 15900
Heating at 5deg F Maximum Capacity Btuh 7061 10900 9194 12500 13022
Power Supply Phase Cycle Voltage 1-phase 60Hz 208 230V 4
Voltage
Indoor - Outdoor S1 - S2 AC 208 230V
Indoor - Outdoor S2 - S3 DC12-24V
Indoor - Remote Controller Wireless Type (Optional Wired Controller DC 12V)
Indoor Unit
MCA A 10
Fan Motor FLA 076
Airflow at Cooling (Lo-Med-Hi-Super HI-Powerful) 1
DRY (CFM) 145-170-237-321-399 162-226-339-381 145-170-237-321-399 162-226-381-410 205-272-335-420-533
WET (CFM) 109-134-201-286-364 144-202-307-343 109-134-201-286-364 144-202-350-367 170-237-300-385-498
Airflow at Heating (Lo-Med-Hi-Super HI-Powerful) 2
WET (CFM) 145-170-237-321-406 166-240-367-381 145-170-237-321-406 166-240-399-420 205-247 -304-367-463
Sound Pressure Level at Cooling (Lo-Med-Hi-Super HI-Powerful) 1
dB(A) 19-22-30-37-43 22-31-39-42 19-22-30-37-45 22-33-43-45 26-32-38-44-49
Sound Pressure Level at Heating (Lo-Med-Hi-Super HI-Powerful) 2
dB(A) 19-22-30-37-43 22-31-40-42 19-22-30-37-43 22-33-43-44 26-30-35-40-46
External Finish Color Munsell No 10Y 92 I 02
Dimension Unit
Wln 31-716 31-38 31-716 31-38 31-716
0 In 9-118 10-18 9-18 10-18 9-18
H In 11-58
Weight Unit Lbs 22 27 22 27 22
Field Drainpipe Size 00 In 58
Outdoor Unit
MCA A 12
MOCP A 15
Fan Motor FLA 050 056 050 056 050
Compressor
lVIodel (Type) DC INVERTER-driven DC INVERTER-driven Twin
Rotary DC INVERTER-driven DC IIWERTER-driven Twin Rotary
RLA 66 86 66 86 74
LRA 82 108 82 108 93
Airflow (CoolingHeating) CFM 11511225 1102 11187 12291172 1102 11187 12431229 Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(A) 46 48 49 48 49
Sound Pressure Level at Heating 2 dB(A) 50 49 51 49 51
External Finish Color Munsell No 3Y 78 11
Dimensions
Wln 31-12
0 In 11-114
H In 21-58
Weight Lbs 66 80 77 80
Remote Controller Type Wireless Remote (Optional Wired Controller)
Refrigerant
Type R410A
Charge Lbs Oz 112 29
Oil Type (fl oz) NE022 (108) NE022 (152)
Refrigerant Pipe Gas Side 00 In 38 12
Liquid Side 00 In 14 14
Refrigerant Pipe Length Height Difference (Max) Ft 40
Length (Max) Ft 65 I
Connection Method IndoorOutdoor FlaredFlared
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg e) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg e) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg e) Outdoor DB 47deg F(8deg e) WB 43deg F(6deg e) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg e) Outdoor DB 17deg F(-8deg e) WB 15deg F(-9deg e) 4 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice
12 +MITSUBISHI ELECTRIC LIMITED WARRANTY ISeven-year warranty on compressor Five-year warranty on parts
- shy(MSY(Z)-D30NA MODEL SHOWN)
Vl J
09 (I)
I
N o J (I)
s Vl N Vl
-0 (I) n 31 n OJ 0 o J V)
Model Name Indoor Unit MSZ-GE18NA MSZ-FE18N MSZ-GE24NA MSZ-D30NA MSZ-D36NA
Outdoor Unit MUZ-GE18NA MUZ-FE18rK MUZ-GE24NA MUZ-D30NA MUZ-D36NA Rated Capacity Btuh 17200 18000 22500 30700 33200
Capacity Range Btuh 3700-18700 8200-25200 8200-31400 9800-30700 9800-33200
Total Input W 1640 (240-2070) 1270 (570-2280) 1800 (570- 3580) 3850 (620-3850) 4360 (620-4360) Cooling 1
Energy Efficiency SEER 192 202 190 145
Moisture Removal Pintsh 46 27 27 99 11 3
Sensible Heat Factor 071 084 075 064 062
Rated Capacity Btuh 21600 21600 27600 32600 35200
Capacity Range Btuh 3500-25200 7500-29700 7500-36900 8700-34000 8700-36000 Heating at 47deg F 2
Total Input W 1900 (230-2680) 1540 (520-2240) 2340 (520- 3650) 3360 (520-3600) 3840 (520-4100)
HSPF (Region IV) BtuhIW 10 103 10 82
Rated Capacity Btuh 13400 11700 16000 19500 21800
Heating at 17deg F 3 Total Input W 1450 2180 3290 2400 2820
Maximum Capacity Btuh 17200 19300 24600 20800 22800 Heating at 5deg F
Maximum Capacity Btuh 13562 21 600 21160 16305 19090
Power Supply Phase Cycle Voltage 1 Phase 60Hz 208230V 4
Indoor - Outdoor S1-S2 AC 208 230V Voltage Indoor - Outdoor S2-S3 DC12-24
Indoor - Remote Controller Wireless Type (Optional Wired Controller DC12V) MCA A 10 Fan Motor FLA 076
DRY (CFM) 230-275-339-420-533 388-469-628-738 388-469-628-738 389-639-848 Airilow (Cool) (Lo-Med-Hi-Super HI-Poweriul) 1
WET (CFM) 194-240-304-385-498 347-420-562-661 347-420-562-661 350-576-763
Airilow (Heat) (Lo-Med-Hi-Super HI-Poweriul) 2 DRY (CFM) 230-275-339-431-512 388-469-628-738 388-469-628-738 445-639-848
Sound Pressure Level (Cooling) (Lo-Med-Hi-Super 28-33-38-44-49 34-41-49-53 34-41-49-53 32-42-49
HI-Poweriul) 1
Sound Pressure Level (Heating) (Lo-Med-Hi-Super dB(A)
Indoor Unit 28-33-38-43-48 32-41-49-52 32-41-49-52 34-42-49-49HI-Poweriul) 2
External Finish Color Munsell No 1 OY 9202
W In 31-716 43-516 46-116
Dimension Unit D In 9-18 9-38 11-58
H In 11-5 8 12-1316 14-38
Weight Unit Lbs 22 37 40
Field Drainpipe Size OD In 58
MCA A 14 171 21
MOCP A 15 20 25
Fan Motor FLA 093
Model (Type) DC INVERTER-driven Twin Rotary
Compressor RLA 100 129 16
LRA 125 161 20
Airilow CFM 1730 1659 17691 701 1941
Outdoor Unit Refrigerant Control Linear Ex~ansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(A) 54 55 56
Sound Pressure Level at Heating 2 dB(A) 56 55 57
External Finish Color Munsell No 3Y 7811
W In 33-116
Dimensions D In 13
H In 33-716 34-58 33-716
Weight Lbs 119 141
Remote Controller Type Wireless Remote (Optional Wired Controller)
Type R410A
Refrigerant Charge Lbs Oz 3 7 43 410
Oil Type (FI Oz) NE022 (152) FV50S (135) NE022 (29)
Gas Side OD 12 58In
Refrigerant Pipe Liquid Side OD 14 38
Height Difference (Max) 50
Length (Max) Ft
100 I Connection
Mpthon IndoorOutdoor Flared Flared
NOTESTest conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg C) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F (24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F(6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 17deg F(-8deg C) WB 15deg F(-9deg C) 4 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice LIMITED WARRANTY ISeven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 13
(SEZ-KD12NA MODEL SHOWN)
SEZ HEAT PUMP TAX
CREDIT
Model Name Indoor Unit SEZ-KD09NA4 SEZ-KD12NA4 SEZ-KD15NA4 SEZ-KD18NA4
Outdoor Unit SUZ-KA09NA SUZ-KA12NA SUZ-KA15NA SUZ-KA18NA Rated Capacity Btuh 8100 11500 14100 17200
Capacity Range Btuh 3800-10900 3800-13300 3800-17000 3800-19000
Cooling 1 Total Input W 670 920 1170 1380
Energy Efficiency SEER 15 16 155 175 Moisture Removal Pintsh 15 24 26 34 Sensible Heat Factor 080 076 080 079
Rated Capacity Btuh 10900 13600 18000 21600
Heating at 4YO F 2 Capacity Range Btuh 4800-14100 4800-16400 4800-21100 4800-24900
Total Input W 1020 1140 1500 1700 HSPF(lV) BtuhIW 100 Rated Capacity Btuh 6700 9000 11900 13100
Heating at 1 yo F 3 Rated Total Input W 810 920 1200 1350 Maximum Capacity Btuh 7300 9800 13700 15000
Power Supply Phase Cycle Voltage 1 Phase 60Hz 208 230V 4 Indoor - Outdoor S1 - S2 AC 208-230V
Voltage Indoor - Outdoor S2 - S3 DC 12-24V Indoor - Remote Controller See optional accessories chart (pg 26 and 27) MCA A 1 Fan Motor FLA 051 057 074
Airflow (Lo-Med-Hi) DRY (CFM) 194-247-317 247-317-388 353-441-529 423-529-635
WET (CFM) 174-222-285 222-285-349 317 -396-4 76 381-476-572 External Static Pressure 3 In wG 002-006-014-020 Sound Pressure Level dB(A) 23-26-30 23-28-33 30-34-37 30-34-38
Indoor Unit External Finish Galvanized-Steel Sheets
W In 31-18 39 46-78
Dimension Unit D In 27-916
H In 7-78
Weight Unit Lbs 42 50 54 62 Field Drainpipe Size 00 In 1-14
MCA A 12 14
MOCP A 15 Fan Motor FLA 050 093
Model DC Inverter DC Inverter Twin Rotary
I (Type)Compressor
RLA 66 74 10
LRA 82 93 125
Airflow (CoolingHeating) CFM 11511225 12291172 1 2431 229 17301659
Outdoor Unit Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(A) 46 49 54 Sound Pressure Level at Heating 2 dB(A) 50 51 56
External Finish Color Munsell No 3Y 7811
W In 31-12 33-16
Dimensions D In 11-14 13
H In 21-58 33-716
Weight Lbs 66 77 80 119 Remote Controller Type See optional accessories chart (pg 26 and 27)
Type R410A
Refrigerant Charge Lbs Oz 116 2 9
Type (fl Oil
oz) NE022 (108)
Refrigerant Pipe Gas Side OD In 38 Liquid Side 00 In 14
Refrigerant Pipe Height Difference (Max) Ft 40 Length Length (Max) Ft 65
Connection IndoorOutdoor FlaredFlared
Method
316
NE022 (152)
12
50
100
I
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg C) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F(8deg C) WB 43deg F(6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 17deg F(-8deg C) WB 15deg F(-9deg C) 4 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
14 MITSUBISHI ELECTRIC
SEZ STATIC PERFORMANCE CURVES (SEZ-KD12NA4 MODEL SHOWN)
SEZ-KD09NA4 SEZ-KD09NA4 (External static pressure O06[inwG]) 208230V 60Hz
[020] V L
5 [016
~l [0 12
]
SEZ-KD09NA4
~ ltij
~ [008
Jj
]
]
[004J ~
V V Middle
Low
V
19h
Rated point
1
o [141] [176J 1212) )247] [282J [318]
Airll ow rat e [CFM)
SEZ-KD12NA4 (External static pressure O06[inwG]) 208230V 60Hz
[020
5 [016
]
]
[353J
Limit
]
~ V
~ [ [0 12
u ltijJ[008
[004
]
_V ]~ Low
V
k-iddle
Rated POint
o [212) [247] [2 82] [318] [353] [388]
Airtlow rate [C FM]
SEZ-KD1SNA4 (External static pressure O06[inwGl) 208230V 60Hz
[424)
1020]
5 [016
~ ~ [012
~ ltij
~ [008
Jj
J
)
]
[004 ]
o
VV V [ Low
VV
vV High
Middle
I Rated point
[282] [318) [353] [388] [424] [459] [494] [530] [565J
Airllow rat e [CFM]
SEZ-KD18NA4 (External static pressure O06[inwG]) 208230V 60Hz
50 10 20]
] 40
5 [016
s 30 [ (012 )
ltij 20 ~ [008 )~Jj
10 [004]
V
Low
v Limit
rIV High
V [ Middle
~
1
Rated point
f318) [353) [388] [424] [459] [494] [530] [565] [600] [636] [671 )
Airllow rate [CFM]
(External static pressure O14[inwG]) 208230V 60Hz 80
[0 32
70 [028
5 60 [024
20 [0 08
10 [004
]
]
J
]
]
J
]V
]
U~it
V
k
High
~V Rated POI~1 V Middle Low
~
o [141] [1 76] 12121 )247J [282] [318]
Airtlow rate [CFM)
SEZ-KD12NA4 (External stat ic pressure O14[inwG]) 208230V 60Hz
[032]
[028J
5
[353]
J
~ [024
-~ [020] V-is
J V Il Hi9h Rated point
[016
~ ]
V V1 Middle
~ [012
[008]~
[004)
o [212)
[247)
SEZ-KD1SNA4
Low r
[282] [31 8) [353]
Airllow rale [CFM]
[388]
(External static pressure O14(inwG]) 208230V 60Hz
[032J
[424
]
2 V[028
5 [024]
V-i
] V High i [020
] K
Middle Rated point [0 16
g ]
~ -
QJj [0 12
J Low
[008
] I
~
[004
o [282J [318) [353J [388J [424) [459] [4 94] [530) [565)
Airt low rate [CFM]
SEZ-KD18NA4 (External statiC pressure O14(inwG]) 208230V 60Hz
1032
1028
~ 1024
-~ [0 20
is (0 16 ltij E ~ [012
(008
(004
o
I
]
]
)
]
)vlt ]
]
~ V
VV
Low
Limit
V
Ji9h
Middle l
Rated point
1 t
1
~ [318] [353] [388] [424] [459) [4 94] [530) [565) [600] [636] [671)
Airllow rate [CFM]
(External static pressure O20(inwG]) 208230V 60Hz
[032 ]
[028 J
5 [024
~ [020
is [016
1 [012Jj
[008
[004
J
]
]
] )
]
V Low
umz V High
~V
Rated point
Middle
1
[141] [176] [212) [247) [282) [318) [353J
Airtlow rat e [CFM]
SEZ-KD12NA4 (External static pressure O20(inwG]) 208230V 60H z
[032 ] LLimit
)
[0 28
5 ]
V
[024 -~ [020] V Rated point
Highis ~
) V
bull Middle
]~V I
[016
~ ~ [012
] Low
[008
]
[0 04
o [212) [247] [282] [318] [353] [388] [424]
Airllow rate [CFM]
SEZ-KD1SNA4 (External static pressure O20(inwG]) 208230V 60Hz
80 [032 ]
70 [0 28
~ [ O~~ -
ltij
E 30 ~ [0 12
20 [008
10 [004
o
)
J
]
]
JV
J
J
Limit V
LV High
V ~
K Rated point
Middle
VV 1gt
Low
I-
~ [282) [318) (353] (388) (424) 1459] [494] 15301 [565)
Airtlow rate [CFM]
SEZ-KD18NA4 (External static pressure O20[inwG]) 208230V 60Hz
[032
[028
~ [024sect
I [020
~ [016
~ Jj [0 12
[008
[004
o
]
)
]
]
]
~ )
]
]
1V
V 1
V
Low
1 limit
~~~ I ~~ High
~ R~ted pOini
Middle
1 1 -
[31 8) [353] [388] [424) [459] [494] [530] (565) [600] (636) [671J
Airllow rate [CFM)
Vl ~ ca (I)
I
N o ~ (I)
Vl m N Vl
-0 (I) n 3-i n QJ ~ o ~ tn
Note ESP 20S230V 60 Hz See manual for Static Performance Curve including 002 in WG
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts ~MITSUBISH[ ELECTRIC 15
SLZ HEAT PUMP (SLZ-KA12NA MODEL SHOWN)
Model Name Indoor Unit SLZ-KA09NA SLZ-KA12NA SLZ-KA15NA
Outdoor Unit SUZ-KA09NA SUZ-KA12NA SUZ-KA15NA Rated Capacity Btuh 8400 11100 15000
Capacity Range Btuh 3100-10900 3100-13300 3100-22200
Cooling 1 Total Input W 700 920 1460
Energy Efficiency SEER 15 154 16 Moisture Removal Pintsh 12 23 45 Sensible Heat Factor 080 076 080
Rated Capacity Btuh 10900 13 600 18000
Heating at 4r F 2 Capacity Range Btuh 3100-14100 3100-17100 3100-17100 Total Input W 930 1180 1950 HSPF (IV) BtuhIW 96 Rated Capacity Btuh 6200 8300 10200
Heating at 17deg F 3 Rated Total Input W 740 930 1310 Maximum Capacity Btuh 8300 10200 12000
Power Supply Phase Cycle Voltage 1 Phase 60Hz 208 230V 4 Indoor - Outdoor S1 - S2 AC 208-230V
Voltage Indoor - Outdoor S2 - S3 DC 12-24V
Indoor - Remote Controller See optional accessories chart (pg 26 and 27) MCA A 1 Fan Motor FLA 023 028 028
Airflow (Lo-Med-Hi) DRY (CFM) 280-320-350 280-320-390 280-320-390
WET (CFM) 250-290-320 250-290-350 250-290-350
Sound Pressure Level dB(Al 29-32-38 30-34-39 31-35-40
Indoor Unit External Finish Galvanized-Steel Sheets Grille Munsell 64Y 8904
W In 22-7 16 (25-58)
Dimension Unit (Grille) D In 22-716 (25-58
H In 8-316 (1316)
Weight Unit (Grille) Lbs 36 (7) Field Drainpipe Size 0 0 In 1-14 MCA A 12 MOCP A 15 Fan Motor FLA 050
Model (Type) DC INVERTER-driven DC INVERTER-driven
Compressor RLA 66
LRA 82
Airflow (CoolingHeating) CFM 11511225 1 229 1 172
Outdoor Unit Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(AJ 46 49 Sound Pressure Level at Heating 2 dB(AJ 50 51
External Finish Color Munsell No 3Y 781 1
W In 31 shy12
Dimensions 0 In 11-14
H In 21-58
Weight Lbs 66 77
~e R410A
Refrigerant Charge Lbs Oz 1 16
Oil Type (fl oz) NE022 108)
Refrigerant Pipe Gas Side 0 0 In 38 Liquid Side 00 In 14
Height Difference (Max) Ft 40 Refrigerant Pipe Length
Length (Max) Ft 65
Connection Method IndoorOutdoor FlaredFlared
29
Twin Rotary 74
93
12431 229
80
NE022 l152) 12
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg C) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F(8deg C) WB 43deg F(6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 17deg F(-8deg C) WB 15deg F(-9deg C) 4 Indoor units receive power from outdoor units through field-supplied interconnectedwiring Specifications are subject to change without notice
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
16 MITSUBISHI ELECTRIC
MHK1 WIRELESS REMOTE CONTROLLER KIT Exclusive for INVERTER-driven Mr Slimreg Systems VlWireless Technology a J
JMITSUBISHI ELECTRIC
Wireless Receiver
MHK1 Kit includes
09 mMRCH1 WIRELESS REMOTE CONTROLLER I Nbull Backlit easy-to-read display o
bull Dual setpoint control with system changeover J m
bull Enabled with RedLlNKTM reliability
bull Compatible with MCCH1 Vl Portable Central Controller m
N bull Installs Anywhere Vl
MFH1 WIRELESS RECEIVER N Vlbull Required for MRCH1 Wireless
CRemote Controller m bull Enabled with RedLiNK reliability n
31 n OJ o J en
SEZ and SLZ 11 systems with SUZ outdoor unit
Function Description
ONOFF OnOff operation for a single indoor unit
Operation Mode Cool I Drying I Auto I Heat I Fan only Available operation modes dependant on connected system
Temperature Setting Set temperature from 50degF - 8rF depending on operation mode and connected system
System Changeover Deadband Value 2-8degF
Schedule Operation 5-25-1-1
Fan Speed Setting HiMid-2Mid-1 IlowlAuto Available fan speed settings dependant on connected system
Air Flow Direction Setting Air flow angles 100deg - 80deg - 60deg - 40deg and oscilate Available air flow direction settings dependant on connected system
PermitProhibit Function Individual prohibit operations for each remote controller function (ONI OFF Set Temperature and Operation Mode)
Space Temperature Displays the measured space temperature
Error Indication Displays error code
Display Outside Temperature and Humidity
Requires optional MOS1 Outside Air Sensor
Dimensions - ryv x D x H) Remote Controller 5-316 x 1-12 x 3-916 Receiver 3-14 x 1-516 x 6-716
Operating Ambient Temperature Remote Controller 32 - 120degF Receiver -40 - 165degF
Operating Ambient Humidity Remote Controller 5 - 90 RH (non-condensing) Receiver 5 - 90 RH (non-condensing)
Power Supply 2 AA batteries
MRCH1 MIFH1 MRC1
Wireless Wall-Mounted Remote Controllers Wireless Receiver Cable
Accessories MCCH1 MOS1
Portable Central Controllers Outside Air Sensor
MITSUBISHI ELECTRIC 17
MULTIPLE ROOMS WITH INDIVIDUAL CONTROL FROM A SINGLE SYSTEM Enjoy ideal levels of comfort in the rooms you use most with our multi-room system Each room (zone) operates independently People in different rooms - the kitchen master bedroom or living room - can enjoy temperature settings that make each of them most comfortable
If you re looking for a complete comfort solution for several different rooms the MXZ multi-room system is the right choice The system is flexible enough to conform to a particular cooling and heating need and offers numerous different indoor unit combinations In addition up to eight indoor units can be connected to one outdoor unit Now with a SEZ horizontal ducted unit and a MFZ floorshystanding unit homeowners can enjoy an even greater range of zoning options provided by an MXZ system
An MXZ multi-room system is an excellent choice for supplementing capacity to a current system conditioning newly furnished spaces or new additions and replacing a system within a home Homeowners can also benefit from lower energy costs year-round while staying comfortable thanks to Mitsubishi Electrics energy-efficient technologies that are a part of every system that we make
To add to the level of energy efficiency the MXZ -2B20NA and MXZ -3B24NA systems qualify for both ENERGY STARreg and the federal tax credit (See details on page 21 for applicable indoor unit combinations)
At right a single level home with several system types represented (For illustrative purposes only)
MFZ Floor-Standing Indoor Units for MXZ Heat Pump Systems
Floor-standing indoor unit mounts three inches above the floor and has front panel access to the filter for ease of cleaning
The MFZ units provide energy-efficient solutions to provide personalized comfort for difficult areas that may be smaller or dont have usable space on the walls
MFZ units on MXZ systems include the following features bull Top and bottom discharge vanes bull Hot-start technology bull Quiet operation bull Wireless remote control (optional wall-mounted controller)
18 MITSUBISHI ELECTRIC
MSZ Wall-Mounted Indoor Units for MXZ Heat Pump Systems
Providing a wide range of cooling and heating capacities each wall-mounted indoor unit mounts high on a wall and connects to a branch box or the outdoor unit by a refrigerant line run via a 3 hole The MSZ units provide highly efficient solutions to cooling and heating needs and provide personalized comfort for the individual zones in which they are installed
MSZ units on MXZ systems include the following features bull Sleek flat panel design bull Hot-start technology bull Quiet operation bull i-seeM sensor technology (MSZ-FE0912NA models only) bull Enhanced filtration system (MSZ-FE0912NA models only) bull Wireless remote control (optional wired wall-mounted controller)
SLZ Ceiling-Recessed Indoor Units for MXZ Heat Pump Systems
The new SLZ-KA ceiling casette systems offer a wide air-flow pattern for better air distribution
offered to your customers Installation can be done in a hard ceiling (with a access panel for servicing) or placed into a 2x2 drop ceiling With a built-in drain lift mechanism for condensate
removal and a 4 ventilation air intake knockout option the SLZ is ready to handle a variety of installation needs
SLZ units on MXZ systems include the following features bull Wide air-flow pattern for better air distibution bull 4 ventillation air intake knockout bull Built-in condensate lift mechanism bull Wireless RedLlNKTM remote controller
SEZ Horizontal Ducted Indoor Units for MXZ Heat Pump Systems
SEZ ducted units can provide split air-conditioning system advantages with the added benefit of being concealed to provide virtually no visual footprint within the conditioned space other than a register and grille for the air to flow With the use of short run ductwork these units can provide comfort to a single room that needs air dispersed evenly throughout the space unusually shaped rooms and adjacent rooms
The SEZ unit on MXZ systems include the fOllvowin fatures _
g~e~~~~==Zl[bull Concealed design for short-run ductwork bull Quiet operation bull Built-in condensate lift mechanism
JMITSUBISHI ELECTRIC 19
s c t
I
N o J ro o ltro ~ ro ~
DIAMOND COMFORT MXZ MULTI-ZONE SYSTEMS MXZ-B Series multi-zone systems provide personalized comfort control and energy efficiency in up to eight rooms with only a single outdoor unit The MXZ-B Series system features include
bull Individual zone control bull Mix and match flexibility of indoor unit styles and combinations bull A wide range of indoor unit capacities that match the room size and requirements bull Flexible design options to tackle the most challenging multi-room installations bull Efficient systems including three systems [mxz series] that meet energy starltID and
federal tax credit requirements bull Simple quick and cost-effective installation keeps install costs down on new construction
and disruption to a minimum on renovations and refits
Efficiency and performance ratings depend on the number style and capacity of the indoor units installed with each Multi-Zone System
MXZ -2 B20 NA - 1 (2 1 ) MXZ -3 B24 NA (2 13 1) Ou tdoo r Unit Outdoor Uni t
MSZ-GE09NA Indoor Units
SEZ-KD12NA Indoor Unit
MSZ- GE06NA
~~~~li
(At least two indoor units MSZ-GE06NAIndoor Unit must be installed) Indoor Unit
(Two indoor units must be installed )
MXZ -3 B30 NA (2 1 3 1) Outdoor Unit
SEZ-KD12NA Indoor Unit
~~~i
(At least two indoor units MSZ-GE06NA must be installed)
Indoor Unit ~
MFZ- KD12NA Indoor Unit
MXZ-8B48NA (2 1-8 1) Outdoor Unit
(At least two indoor units
must be installed)
(At least two indoor units must be installed)
MFZ-KD09NA Indoor Units
MSZ-GE09NA Indoor Units
SEZ-KD12NA Indoor Unit
MSZ INDOOR UNIT
MSZ-FE18NA
PEAD HORIZONTAL -DUCTED INDOOR UNIT
PEAD-A24AA
MSZ INDOOR UNIT SEZ HORIZONTAL-DUCTED MSZ-FE18NA
INDOOR UNIT MFZ FLOOR-STANDING SEZ-KD18NA INDOOR UNIT
MFZ-KA12NA
20 AMITSUBISHI ELECTRIC
MULTI-ROOM MXZ-8 INVERTER HEAT PUMP R
Model Name Outdoor Unit MXZ-2B20NA-1 5 MXZ-3B24NA 6 MXZ-3B30NA MXZ-4B36NA 7
Indoor Unit
Cooling 1 Non-ductedl Ducted
Rated Capacity Btuh 1800020000 2200023600 28400127400 3540034400
Capacity Range Btuh 7800-20000 12600-25500 12600-28400 12600-36400
Total Input W 2190 (630-219QL 2460 (1000-2950) 3330 l1 000-3330) 3 940 (1 000-4020)
Heating at 4JO F 2 Non-ductedl Ducted
Rated Capacity Btuh 2200022000 2500024600 2860027600 3600034400
Capacity Range Btuh 8500-25500 11400-30600 11 400-36000 11400-43000
Total Input W 2620 (520-2620) 1900 (740-2600) 2220 (740-2820) 3100 (740-3940)
Heating at 1JO F 3 Non-ductedl Ducted
Rated Capacity Btuh 1250012500 1400014000 1600015100 2220020300
Rated Total Input W 13501430 13801570 21202 140 24302340
Maximum Capacity Btu h 1450014500 1880017000 1880018000 2460025400
Maximum Total Inl2ut W 15001590 21202230 21202140 33403450
Power Supply Phase Cycle Voltage 1-phase 60Hz 2081 230V 8
Voltage Indoor shy Outdoor S1 - S2 AC 2081 230V
Indoor shy Outdoor S2 - S3 DC12-24V
Outdoor Unit 4
MCA A 15 19
MOCP A 20
Fan Motor FLA 096 093
Compressor
Model (Type)
DC INVERTER-driven Twin Rotary
RLA 101 11 144
LRA 15
Airflow (CoolingHeating) CFM 14851 640 20681605 13651605 20682068
Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1
dB(A) 49 54 49 54
Sound Pressure Level at Heating 2
dB(A) 51 49 57
External Finish Color Munsell No 30Y 781 1
Dimensions
W In 33-116 35-716
D In 13 12-58
H In 27-1516 35-7116
Weight Lbs 130 150 153
Indoor Unit No of Units 2 23 23 234
Remote Controller Type Associated with the Indoor Unit
Refrigerant
Type R410A
Charge Lbs Oz 515 7 11 813
Oil Type (fl oz)
NE022 (237) NE022 (294)
Refrigerant Pipe Gas Side 00 In AB 38 A 12 BC 38 A 12 BCD 38
Liquid Side 00 In 14
Refrigerant Pipe Length Height Difference (Max) Ft 4933 9
Length (Max) Ft 164 (A+B) 230 (A+B+C) 230 (A+B+C+D)
Connection Method IndoorOutdoor FlaredlFlared
Compatible with the MSZ-A MSZ-GA MSZ-FD MSZ-FE MSZ-GE MFZ-KA and SEZ-KD series indoor units (PLA-18 amp PCA-24 on the MXZ-MXZ-3B PLA-24 amp PCA-24 on the MXZ-4B)
NOTES Test conditions are based on AHRI 210240 One indoor unit is turned off during low-speed testing under the new test conditions Systems actually exhibit higher energy efficiencies during normal operation
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F (35deg C) WB 75deg F (24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F (6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 600 F (160 C) Outdoor DB 17deg F (_80 C) WB 150 F (_90 C) 4 Refer to pages 12 and 13 for Indoor Unit specifications 5 Data from combination of two Indoor Units 9000 Btuh (non-ducted) or one 9000 Btuh and one 12000 Btuh (ducted) 6 Data from combination of two Indoor Units 6000 Btuh and one 9000 Btuh (non-ducted) or three 9000 Btuh (ducted) 7 Data from combination of four Indoor Units 9000 Btuh (non-ducted and ducted) 8 Indoor units receive power from outdoor units through field-supplied interconnected wiring 9 49 Applies to installations where the outdoor unit is installed below the indoor unit
Power factor equals 97 percent
Specifications are subject to change without notice
MULTI-ZONE ENERGY STAR AND TAX CREDIT SYSTEMS
Model Indoor Unit Combinations SEER HSPF
MXZ-2B20NA-1 2 x MSZ- GE09NA 18 8 9
MXZ- 3B24NA 2 x MSZ- GE06NA 1 x MSZshy GE09NA
17 5 9 3
MXZ- 3B24NA 2 x MSZ-GE06NA 1 x MSZ- GE12NA
17 5 93
For more details on all ENERGY STAR and tax credit systems go to wwwmitsubishicomfortcomtaxcredit
See page 25 for additional info on efficiency
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 21
MXZ-8B48NA THE ULTIMATE ZONING SOLUTION
The Mitsubishi Electric MXZ-S84SNA eight-zone unit As a member of the expanding MXZ-B Series of multi-zone systems the MXZ-8B outdoor unit incorporates branch boxes to connect up to eight indoor units MXZ- 8 B48 NA (2 1 - 8 1 )
Outd oor Uni t The INVERTER-driven compressor at the heart of the MXZ-8B -~-- shy
outdoor unit provides variable capacity control allowing the system to adjust to the specific demands of the interior space ~ as needed not the hard start and stop of a traditional system I[iDA Jinstalled in most US homes
The MXZ -8B48NA has only one port on the outdoor unit for two insulated refrigerant lines which run into the home or business to connect to a branch box or boxes From the branch box(es) gas and liquid refrigerant piping run to each of the indoor units The LEV in the branch box(es) controls the refrigerant flow as the load of each zone changes
Through the branch box(es) (the PAC-AKA31 BC three-port andor the PAC-AKA51 BC five-port) the system can connect from two indoor units up to eight indoor units depending on application requirements
The flexibility of the system doesnt stop there The MXZ-8B48NA has rated capacities of 48000 Btuh for cooling and 54000 Btuh for heating System operation however can range from a minimum 12000 Btuh to a maximum 54000 Btuh in cooling and a maximum of 60000 Btuh in heating This type of performance supports a large variety of applications
The MXZ-8B48NA allows for further flexibility because it supports a connected indoor unit capacity from 22 to 130 or 12000 Btuh to a maximum 70200 Btuh depending on diversity
Connectable Indoor Units General Features bull Four-ton outdoor unit can support up to
eight indoor units using branch boxes bull Wide variety of indoor unit styles
-=--_-=-----= - - J _ 1
including wall-mounted floor-standing MSZ-FE09 12 18NA MSZ-GE06 09 12 15 18 24NA ceiling-cassette ducted
bull Individual control up to eight (8) zones using wired or wireless controls
bull Advanced microprocessor control bull Auto restart following a power outage bull Self-check function offering SEZ-KD09 1215 18NA PEAD-A24AA
integrated diagnostics ~--- Jbull Limited warranty five years on parts and
defects and seven years on compressors
SLZ-KA09 1215NA MFZ-KA09 12 18NA
22 MITSUBISHI ELECTRIC LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
I
RMULTI-ROOM MXZ-8 INVERTER HEAT PUMP
Model Name Outdoor Unit MXZ-BB4BNA Cooling 1 Rated Capacity
Non-ducted Rated Total Input Ducted
Maximum Capacity
Rated CapacityHeating at
Rated Total InputIndoor Unit 4JO F 2 Non-
ductedDucted Maximum Capacity
Rated Capacity Heating at
Rated Total InputlJO F 3 Non-ductedDucted Maximum Capacity
Power Supply Phase Cycle Voltage
Indoor - Outdoor Sl - S2 Voltage
Indoor - Outdoor S2 - S3
MCA
Recommended FuseBreaker Size
Fan Motor
Compressor
Airflow (CoolingHeating)
Refrigerant Control
Outdoor Unit Sound Pressure Level at Cooling 1
Sound Pressure Level at Heating 2
External Finish Color
Dimensions
Weight
Total Capacity 22-130
Indoor Unit ModelQuantity
Remote Controller Type
Type
Refrigerant Charge
Oil
Gas Side OD Refrigerant Pipe
Liquid Side OD
Height Difference (Max)
Maximum Distance between (Outdoor unit and farthest indoor unit)
Refrigerant Pipe Length Maximum Pipe Length -Branch box to Indoor Unit
Total Maximum line length between Branch Box and All Connected Indoor Units
Total Length (Max)
Connection Method IndoorOutdoor
Includes both branch boxes if there are two
Branch Boxes (At least one branch box required)
Btuh
W
Btuh
Btuh
W
Btuh
Btuh
W
Btuh
A
A
Type x Quantity
Motor Output (kW)
Model (Type)
Motor Output (kW)
CFM
dB(A)
dB(A)
W In
D In
H In
Lbs
Btuh
Lbs Oz
Type (fl oz)
In
In
Ft
Ft
Ft
Ft
Ft
4800048000
57806470
54000
5400054000
48205270
60000
3300034700
29503390
3660036550
1 Phase 60Hz 208 230V
AC 208-230V
DC12-24V
32
40
Propeller x 2
0086 + 0086
DC INVERTER-driven Scroll
29
3530
Linear Expansion Valve
54
55
Munsell No 3Y 78 11
37-716
13+1-3 16
53-3 16
278
12000 - 70200
600 - 24000 2-8
Associated with Indoor Unit Model
R410A
18 112
FV50S (73)
58
38
6698 4
230
49
197
377
FlaredFlared
Compatible with the MSZ-A MSZ-FO MSZ-FE MSZ-GE MFZ-KA SEZ-KD PLA and PEAD series indoor units
NOTES Test conditions are based on AHRI 210240 One indoor unit is turned off during low-speed testing under the new test conditions Systems actually exhibit higher energy efficiencies during normal operation
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F (35deg C) WB 75deg F (24deg C)
2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 4]0 F (8deg C) WB 43deg F (6deg C)
3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 17deg F (-8deg C) WB 15deg F(-9deg C)
4 66 applies to installations when the outdoor unit is installed below the indoor unit
Power factor equals 97 percent
Specifications are subject to change without notice
Note Maximum installed capacity is the maximum total of all connected indoor units NOT the maximum capacity produced
Only a single Lineset is needed from the outdoor unit to branch box
See page 25 for MXZ-B information on efficiency
Required Branch Boxes for MXZ-SB4BNA (Maximum of 2 branch boxes can be connected to one outdoor unit requires joint MSDD-50AR-E or MSDD-50BR-E)
s c d N o J ro Vl
0 ro n 3i n OJ d o J U)
PAC-AKA51 BC Branch Box
PAC-AKA31 BC Branch Box LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 23
MSZ WALL-MOUNTED INDOOR UNITS (FOR MXZ-8 OUTDOOR UNITS)
R
(MSZ-GE12NA MODEL SHOWN)
-000 IIIIIII 9000 9000 12000 12000 14000 17200
Heating at 4r Rated Capacity Btuh 7200 10900 10900 14400 13600 18000 21600
F2 Power Supply I Phase Cycle Voltage J -phase 60Hz 208 230V 3
Iindoor Outdoor S1 S2 AC 208 230V
Iindoor Outdoor S2 S3 DC12-24V Voltage
Iindoor Remote vomr Iller Wireless Type (Optional Wired vomroller DC 12V)
IMCA A 10 IFan Motor FLA 076
DRY 162-226shy145-170shy
162-226shy205-272shy 230-275shy
Airflow at Cooling (CFM)
145-170-237-321-399 339-381
237 -321shy381-410
335-420shy 339-420shy(Quiet-Lo-Med-Hishy 399 533 533 Super Hi or Lo-Med-
WET 144-202shy109-134shy
144-202shy170-237shy 194-240shy
Fan Hi-Powerful)1 (CFM)
109-134-201-286-364 307-343
201-286shy350-367
300-385shy 304-385shy364 498 498
Airflow at Heating 145-170shy 145-170shy 145-170shy 205-247shy 230-275shy
(Quiet-Lo-Med-Hi- WET 233-321shy 237-321shy
166-240shy237-321shy
166-240shy304-367shy 339-431shy
Super Hi or Lo-Medshy (CFM) 406 406
367 -381 406
399-420 463 512
Hi-Powerful) 2 Sound Pressure Level at Cooling
19-22-30shy 26-32-38shy 28-33-38shy(Quiet-Lo-Med-Hi-Super Hi or Loshy dB(A) 19-22-30-37 -43 22-31-39-42
37-45 22-33-43-45
44-49 44-49Med-Hi-Powerful) 1
Sound Pressure Level at Heating 19-22-30shy 26-30-35shy 28-33-38shy
(Quiet-Lo-Med-Hi-Super Hi or Loshy dB(A) 19-22-30-37 -43 22-31-40-42 37-43
22-23-43-44 40-46 43-48
Med-Hi-Powerful) 2
I External Finish Color Munsell No 10Y 92 02
IWln 31 middot716
Dimension Unit 10 In 9 18 10-18 9middot18 10-18 9-18
IH In 11-58
I Weight Unit ILbs 22 27 22 27 22 I Field Drainpipe ~D lin 58 Remote Con-
Type Wireless Remote (Optional Wired Controller) troller
ITvpe B41QA Refrigerant ~s$ideOD lin 38 Pipe I Liquid Side 00 In 14
Connection IndoorOutdoor FlaredFlared
Method
1~
II 18000 22500
21600 27600
388-469shy 38$-469shy628-738 628-738
347-420shy 347-420shy562-661 562-661
388-469shy 388-469shy628-738 628-738
34-41-49-53 34-41-49-53
32-41-49-52 32-41-49-52
43-516
9-38
12-1316 37
58 38
MXZ-2B20NA is also compatible with the MSZ-A and MSZ-FD series indoor units NOTES Test conditions are based on AHRI 210240
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F(6deg C) 3 Indoor units receive power from outdoor units through field-supplied wiring
Specifications are subject to change without notice LIMITED WARRANTY Seven-year warranty on compressor Five-year warranty on parts For data on specific indoor unit combinations see page 21
SEZ DUCTED INDOOR UNIT (FOR MXZ-8 OUTDOOR UNITS)
I
Notes 1 Cooling-Indoor DS 80deg F(267deg C) WS 67deg F(194deg C) Outdoor DS 95deg F (35deg C) WS 75deg F(239deg C)
2 Heating-Indoor DS 70deg F(211 deg C) WS 60deg F(156deg C) Outdoor DS 47deg F (83deg C) WS 43deg F(61 deg C)
3 External static pressure is factory set to 006 WGAdjustable via the
1---------t---+-----L-------------1~---__I PAR-21MAA
1--_____----__________+-____---L____----~_____________1 4 Indoor units receive power
jE~~~~-------------r----1-----~-~~~~~~~~-----___1 from outdoor units through fieldsupplied interconnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven-year warranty on compressor Five-year
1---------------------+---+------------------------1 warranty on parts
~--__I_~----------+-------~l----------I For data on specific indoor unit combinations see page 21 - 23
I--~------+~-----------~----------r_------------I
- Reference page 17 for SEZ static performance curves
24 MITSUBISHI ELECTRIC
25-30-35-40 26-31-36-41 35-38-42-46
25-30-35-40 28-31-36-41 35-38-42-47
MFZ FLOORLOW WALL INDOOR UNIT (FOR middotMXZ-8 OUTDOOR UNITS)
------shy
-==
Airflow at Heating (CFM) 177-198-219-332 184-201-219-335 261-275-297-434
Voltage
Fan
Airflow at Cooling (Lo-Med-Hi-Super Hi)1
169-205-251-314 251-279-325-394
163-197-241-303 170-207-252-309 241-269-313-379
(Lo-Med-Hi-Super Hi) 2
SLZ CEILING-RECESSED INDOOR UNIT (FOR MXZ-8 OUTDOOR UNITS) EFFICIENCY RATINGS
Voltage
Fan
Galvanized-steel SheetsMunsell 64Y 89 04
Refrigerant Pipe
Model Indoor Unit Type SEER HSPF
MXZ-2B20NA-1
Non-dueted 18 89
Dueted and Non-dueted 1675 87
Dueted 155 85
MXZ-2B20NA-1 ENERGY STAR amp
TAX CREDIT 2 x MSZ-GE09NA 18 89
MXZ-3B24NA
lJon-dueted 175 93
Dueted and Non-dueted 1625 89
Dueted 150 85
MXZ-3B24NA ENERGY STAR amp
TAX CREDIT
2 x MSZ-GE06NA 1 x MSZ-GE09NA
175 93
MXZ-3B24NA ENERGY STAR amp
TAX CREDIT
2 x MSZ-GE06NA 1 x MSZ-GE12NA
175 93
MXZ-3B30NA
Non-dueted 175 105
Dueted and Non-dueted 16 100
Dueted 145 95
MXZ-4B36NA
Non-dueted 18 93
Dueted and Non-dueted 16 5 92
Dueted 150 9 0
MXZ-BB4BNA
Non-dueted 15 87
Dueted and Non-dueted 14B B8
Dueted 147 89
Connection IndoorOutdoor FlaredFlared
Method
Notes 1 Cooling-Indoor DB 80deg F(267deg C) WB 67deg F(194deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(239deg C) 2 Heating-Indoor DB 70deg F(21 1 deg C) WB 60deg F(156deg C) Outdoor DB 47deg F(83deg C) WB 43deg F(61 deg C) 3 Indoor units receive power from outdoor units through field supplied interconnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 25
Notes 1 Cooling-Indoor DB 80deg F(267deg C) WB 67deg F (194deg C) Outdoor DB 95deg F (35deg C)WB 75deg F (239deg C)
2 Heating-Indoor DB 70deg F(211deg C) WB 60deg F (156deg C) Outdoor DB 47 F (83deg C) WB 43deg F (61 deg C)
3 Indoor units receive power from outdoor units through field supplied interco(lnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven -year warranty on compressor Five-year warranty on parts
Presently there is no 1 1 system with the MFZ indoor unit
s c
N o J ro Vl
C ro n ~ n OJ t o J V)
M-SERIES RATING CONDITIONS
INDOOR INTAKE AIR TEMPERATURE
OUTDOOR INTAKE AIR TEMPERATURE
COOLING
MAXIMUM
95degF DB 71 degF WB (MU SUZ MXZ-2B20-13B243B304B36) 90degF DB 73degF WB (MUZY-GE MUZ-FE MUzy-D)
115degF DB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B24 3B304B368B48)
MINIMUM 67degF DB 57degF WB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B201 3B243B304B36)
14degF DB (MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B24 3B304B36) 23degF DB (MXZ-8B48) 6rF DB (MU)
MAXIMUM 80degF DB 6rF WB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B243B304B36)
75degF DB 65degF WB (MUZY-GE MUZY-GA24 MUZ-FE SUZ MXZ-2B20-1 3B243B304B36) 70degF DB (MXZ-8B48)
HEATING
MINIMUM 70degF DB 60degFWB (MUZ-GE MUZ-GA24 MUZ-D MUZ-FE SUZ MXZ-2B20-1 3B243B304B36)
-13degF DB -15degFWB (MUZ-FE) -4degF DB -5degF WB (SUZ MUZ-GE) 5degF DB 4degF WB (MUZ-GA24 MXZ-8B48NA) 6degF DB 5degF WB (MXZ-2B20-1 3B24 3B304B36) 14degF DB 13degFWB (MUZ-D)
MU units operate at intake air temperature down to 10deg Fwith the addition of an ICM-326HM-1 low temperature control
REFRIGERANT TUBING SETS
OPTIONAL ACCESSORIES
REFRIGERANT LINE LENGTH FLARE FLARE _INDOOR UNIT OUTDOOR UNIT
MS-A09WA MU-A09WA 35 MS-A12WA
65 MU-A12WA 35
MSY-GE09NA 65
MUY-GE09NA 40
MSY-GE12NA
65
MUY-GE12NA 65 40
MSY-GE15NA MUY-GE15NA 40
MSY-GE18NA
65
MUY-GE18NA 100 50
MSZ-GE09NA MUZ-GE09NA 65 40
MSZ-GE12NA MUZ-GE12NA 40
MSZ-GE15NA
65
MUZ-GE15NA 40
MSZ-GE18NA
65
MUZ-GE18NA 100 50
MSY-GE24NA MUY-GE24NA 100 50
MSZ-GE24NA MUZ-GE24NA 100 50
MSY-D30NA MUY-D30NA 100 50
MSZ-D30NA MUZ-D30NA 50
MSY-D36NA
100
MUY-D36NA 50
MSZ-D36NA
100
MUZ-D36NA 100 50
MSZ-FE09NA MUZ-FE09NA 40
MSZ-FE12NA
65
MUZ-FE12NA 40
MSZ-GE06091215NA MSZ-FE0912NA
65
MXZ-2B20NA-1 164 4933MFZ-KA0912NA SEZ-KD09 1215NA
MSZ-GE0609 121518NA MSZ-FE091218N MFZ-KA09 1218NA MXZ-3B24NA 164 4933 SEZ -KD09 12 15 18NA SLZ-KA09 12 15NA
MSZ-GE0609 121518NA MSZ-GA24NA MSZ-FE091218NA
MXZ-3B30NA 4933230MFZ-KA091218NA SEZ -KD09 121518NA SLZ-KA09 12 15NA
MSZ-GE0609121518NA MSZ-GE24NA MSZ-FE09 12 18NA
MXZ-4B36NA 230 4933MFZ-KA091218NA SEZ -KD09121518NA SLZ-KA09 12 15NA
MSZ-GE0609 12 15 18NA MSZ-GE24NA MSZ-FE09 12 18NA
MXZ-8B48NA 6698377MFZ-KA091218NA SEZ-KD09121518NA SLZ-KA09 12 15NA
PART NUMBER I USE WITH I DESCRIPTION
Port Adapters and Connection Pipes MAC-A454JP-E MXZ-Series Adapter 38 X12
MAC-A455JP-E MXZ-Series Adapter 12 X38
MAC-A456JP-E MXZ-Series Adapter 12 X58
MSDD-50AR-E MXZ-Series Branch Box Tee Distribution Pipe - Flare Connection between two branch boxes
MSDD-50BR-E MXZ-Series Branch Box Tee Distribution Pipe - Braze Connection between two branch boxes
PAC-493PI MXZ-Series Adapter 14 X38
PAC-SG76RJ-E MXZ-Series Adapter 38 X58
OPTIONAL ACCESSORIES CONTINUED ON NEXT PAGE
49 amp 66 applies to installations in which the outdoor unit is installed below indoor unit26 MITSUBISHI ELECTRIC
OPTIONAL ACCESSORIES (CONTINUED)
PART NUMBER USE WITH DESCRIPTION Control Options and Accessories
M21 JKO 307 M-Series Indoor Units Remote temperature sensor for M-Series indoor units
MAC-397IF-E
MAC-399IF-E
PAC-YU25HT
PAR-21 MM-G
M-Series INVERTER Units
M-Series INVERTER Units
SEZ-KD Indoor Units
Use with P-Series SEZ and for wired M-Series Controller
MA and contact terminal interface - Required to use PAR-21 MM wired wall mount controller with M-Series Systems
CMCN M-NET control adapter I Interface for Mr Slim M-Series MSYZ SEZ I MFZ
External Fan I Heater control relay adapter
Deluxe MA remote controller (Requires MAC-397IF-E for use with M-Series - MSYZ MFZ)
SEZ Wireless remote controller for SEZ units (Requires signal receiver PAR-SA9FA-E)PAR-FL32MA
PAR-SA9CA-E SEZ Wireless signal receiver for SEZ
3-pole disconnect switch 30A 600V turns off power between indoor and outdoor units shyM-SeriesTAZ-MS303
mounts in 2 X 4 utility box and requires standard single gang switch platecover - Low Ambient
ICM-326HM-2 M-Series Non-INVERTER units Low ambient head pressure controller MUZ-GE091215 IVIUZ-FE0912 SUZ-KD091215
Drain pan heaterMAC-640BH-U outdoor unit
MAC-641 BH-U MUZ-GE18 SUZ-KD18 outdoor unit Drain pan heater Filters
MAC-1415FT-E Anti-allergy enzyme filter
MAC-2300FT
MSZlMSY-D3036
Anti -allergy enzyme filter
MAC-308FT
MSYMSZ-GA24
MSZ-FD912 I FE0912 Platinum deodorizing filter
MAC-408FT-E Anti-allergy enzyme filter
MAC-415FT-E
M-Series Indoor Unit - GE09GE12GE15GE18
MFZ-KA Air Cleaning FilterAnti-Aliergy Enzyme Filter
MAC-418FT Anti-allergy enzyme filter
Filter Boxes
FBL1-1
MSZ- FD912 I FE091 2
FB Series Filter Box for SEZ-KD09NA Optional filter box with MERV 8 filters
FB Series Filter Box for SEZ-KD1215NAFBL1-2 Optional filter box with MERV 8 filters
and PEA-A 12M
FBL1-3 FB Series Filter Box for SEZ-KD18NA Optional filter box with MERV 8 filters
Pumps
SI1730-230 MSYZ - 30000 Btuh or greater Sauermann mini condensation pump 230V
S13100-115 MS-Series - non-INVERTER Sauermann mini condensation pump 115V
S13100-230 Sauermann mini condensation pump 230VMSYZ - Less than 30000 Btuh
Miscellaneous BRP-1 Bottom Return Plate for SEZ-KD09NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-2 Bottom Return Plate for SEZ-KD12KD15-NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-3 Bottom Return Plate for SEZ-KD18NA Converts low profile ducted indoor unit from rear return to bottom return
BV12FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderreglnsulated - 12
BV14FSI Use with any Mr Sl im multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 14
BV38FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 38
BV58FSI Use with any IVIr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 58
Condensing unit wall mounting brackets (set of 2) - 440 lb capacity painted steel NOTE CWMB1 IVIU and PU outdoor units Installer is responsible to select and provide suitable hardware and materials to insure proper
mount of bracket to wall
DSD-400N M-Series DiamondBacktrade Platform Stands MUZ-GE18 I MUZ(y)-03036 I
MAC-811DS Drain socket assemblySUZ-KA18
MAC-851DS MUZ-FD0912 Drain socket
MAC-855SG M-Series Air outlet guide
MAC-856SG M-Series Air outlet guide - MXZ-3B24 I 3B30 I 4B36 NA
MAC-860DS MUZ-GE091215 I MUZ-FE0912 Drain socket
MAC-889SG M-Series Air outlet guide- MXZ-2B20NA
MAC-S99SG M-Series Air outlet guide
PAC-SG59SG-E IVIXZ-SB4SNA Air outlet guide (1 piece) I MXZ-SB48NA (Requires 2 pieces)
PAC-SG61 DS-E MXZ-8B4SNA Drain socket - connector
PAC-SG64DP-E MXZ-SB48NA Drain pan
RCMKP1CB lVI-Series Wireless Lockdown bracket for remote controller
lILTRILlTE1 All M-Series Condensing unit mounting pad 16 x 36 x 3
MITSUBISHI ELECTRIC 27
MXZ-8 Series Port Adapter chart Port Adapter Unit Port
Combinations Required Size
MXZ-2B20NA-1
2-zone combinations wi NA
A 38 x both units s12K 14
1-MAC-A454JP-E B 38 x
6+15 14
9+15 1-MAC-A454JP-E
MXZ-3B24NA
All rated 2-zone combina-NA
A 12 x tions 14
All rated 3-zone combina-NA
B 38 x tions 14
C 38 x 14
MXZ-3B30NA
2-zone combinations wi at NA
A 12 x least one unit s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
9 + 24 14
3-zone combinations wi 1-MAC-A455JP-E
all units s12K
All other rated 3-zone NA
comb
MXZ-4B36NA
2-zone combinations wi at NA
A 12 x least one un it s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
6 + 24 14
1-MAC-A456JP-E D 38 x
9 + 24 14
3-zone combinations wi at NA
least two units s12K
3-zone combinations wi 1-MAC-A454JP-E
two units15K
6+6+24 or 6+9+24 1-MAC-A456JP-E
9+9+24 1-MAC-A456JP-E
4-zone combinations wi at 1-MAC-A455JP-E
least three units s12K
6+6+15+15 1-MAC-A454JP-E
6+6+15+15 1-MAC-A454JP-E
Note When using the Pu-A24BA PCA-A24KA or PEAD-A24AA two port adapter will be needed 1-MAC-A456JP-E (12 x 58) A port or 1-PACshySG76RJ-E (38 x 58) B C and D ports and 1-PAC493PI (14 x 38)
28 JMITSUBISHI ELECTRIC
6+6+246+9+24 6+12+249+9+24 9+12+24 or 12+12+24
6+15+24 6+18+24 9+15+249+18+24 12+15+24 or 12+18+24
15+15+24 15+18+24 or 18+18+24
15+24+24 or 18+24+24
Combinations of 4 or more zones
1-PAC-SG76RJ-E
See notes for application below
2
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
See notes for application below
PORT A =38 gas x 14 liquid
PORT B =38 gas x 14 liquid
PORT C =38 gas x 14 liquid
PORT A =38 gas x 14 liquid
PORT B = 38 gas x 14 liquid
PORT C = 38 gas x 14 liquid
PORT D =38 gas x 14 liquid
PORT E =12 gas x 14 liquid
Notes for application bull Check the lineset sizes for your indoor selected models bull Select the branch box or boxes needed for your application bull Compare indoor unit lineset sizes as compared to branch
box sizes bull Connect 15K + indoor units to the larger port on the
(PAC-AKA51 BC) bull Adapt lineset size with appropriate port adapter from
above list bull When using the PU-A24BA or PEAD-A24AA two port
adapter will be needed 1-MAC-A456JP-E (12 x 58) or 1-PAC-SG76RJ-E (38 x 58) and 1-PAC493PI (14 x 38)
-fv
~ DIAMONDBACKtrade
~) BV-Series Ball Valves Model numbers
BV14FFSI BV38FFSI
LISTED 891N REFRIGERANT
BV12FFSI VALVE bull Engineered for Mini-split andBV58FFSI
Multi-split HVAC Units bull Size available 14 38 12 58
bull Full Port Designbull Fully factory assembled bull Furnace brazed and pressure tested bull 700 PSIG Rated bull Each ball valve is equipped with Schraderreg Valve
for refrigerant service bull R-410A Compatible bull Design working pressure 700 PSIG bull Temperature range bull Flare Connections
-40 0 F to +3250 F (-400 C to + 1490
C) bull Forged brass body and seal cap bull Teflonreg seals and gaskets (no synthetic a-rings) bull Seal cap design permits valve operation without
removal of seal cap bull Suitable for use with R-11 R-22 R-123 R-125
R-134A R-236FA R-4202A R-402B R-404A R-407C R-410A R-500 R-502 and R-507
bull One year limited materials and workmanship
Part Number SAE Flare
A B C 0 E F
BV14FFSI 14 619 260 180 122 142 110
BV38FFSI 38 630 267 180 122 142 110
BV12FFSI 12 651 267 180 122 142 110
BV58FFSI 58 664 267 180 128 142 110
Ball valves come With an insulation piece warranty on Ball Valves
~ DIAMONDBACKtrade
~) Platform Stands
Lift the Mitsubishi Electric Comfort Solution
outdoor unit to new heights with our Diamondback Platform Stands
bull Easy to install
bull Available for all sizes of Mr Slim outdoor units
bull Color matched to the outdoor units
Model Number DSD-400N
L 15-34 x W 3-14 x H 3-14
r
)MITSUBISHI ELECTRIC 29
~ DIAMONDBACKtrade LINESETS
~~
Twin-Tube Lineset Insulation Design
bull Balanced outside diameter for uniform coiluncoil position stability
bull Minimum 12 insulation thickness on both tubes Diamondback Advantages include the following features
bull Quick efficient and economical field installation using factory applied Twin Tube insulation and flare connections with flare nuts mounted
bull Correct lengths for reducing waste and time
bull Quality consistency and economy
bull All Diamondback Lineset tubing is tested in accordance with ASTM E243
Filter Boxes
FB Series filter boxes are available in compatible sizes for all Mr Slim horizontal ducted indoor units
FBL 1 filter boxes include 1 thick pleated MERV 8 filter(s) installed Filters are tested in accordance with ANSIASHRAE Standard 522 and Rated Class 2 under UL Standard 900
The cabinet is constructed of non-insulated 20 gauge G-60 galvanized
FBL1-1 FB Series Filter Box for SEZ-KD09NA
FBL1-2 FB Series Filter Box for SEZ-KD12KD15-NA
FBL1-3 FB Series Filter Box for SEZ-KD18NA
steel with foam gasket and provides an air-tight connection to indoor unit and access door Gasket material complies with UL 723 requirements
A screw-through cabinet design for secure attachment to indoor unit and return connection in rear is easily field-converted to bottom return
30 MITSUBISHI ELECTRIC
bull
bull
bull
bull
bull
bull
LINE-HIDE~ Put a professional finish on air-conditioning
installations with an easy-to-install modular
system that beautifies exteriors and
protects Linesets drainlines and wiring
Can be use it indoors too Meets UL94v-O for interior applications
Has snap-on covers and a full selection of couplings elbows T-joints caps and more for any application complex or simple
Offers high-quality PVC with UV inhibitors for outdoor service in all weather conditions
Can be painted with most house paints to match exterior decors
Is not just for HVAC Hide any exterior cabling piping or wiring
Available in four sizes 2-14 3 4 and 6 tubes
Download a brochure at wwwline-hidecom to find out more information
For more information on our CITY MULTI VRF product line visit our website at wwwmitsubishiprocom
_lIJrUlllln ~ ~IIII1 fInll l
~
l bull bull
JMITSUBISHI ELECTRIC 31
~ (MSZ-FE12NA MODEL SHOWN)
MSZ HEAT PUMP TAX
CREDIT
Model Name
Cooling 1
Indoor Unit Outdoor Unit
Rated Capacity Btuh
MSZ-GE09NA MUZ-GE09NA
9000
MSZ-FE09NA HshyMUZ-FE09NA bull
9000
MSZ-GE12NA MUZ-GE12NA
12000
MSZ-FE12NA MUZ-FE12NA
12000
H-bull MSZ-G MUZ-G
14000
Capacity Range Btuh 3800-12200 2800-9000 3800-13600 2800-12000 3100-18200
Total Input W 660 (205-1200) 580 (160-650) 960 (205-1300) 930 (160-960) 1080 (160-2000)
Energy Efficiency SEER 21 26 205 23 21
Moisture Removal Pintsh 15 21 25 29 27
Sensible Heat Factor 082 076 074 073 080
Heating at 47deg F 2
Rated Capacity Btuh 10900 10900 14400 13600 18000
Capacity Range Btuh 4500-14100 3000-18000 5500-18100 3000-21000 4800-20900
Total Input W 760 (255-1200) 710 (150-2250) 1170 (340-1660) 950 (150-2250) 1600 (270-2010) HSPF (IV) BtuhlW 10 106 10
Heating at 17deg F3 Rated Capacity Btuh 6600 6700 8800 8300 11300 Rated Total Input W 700 650 900 800 1150 Maximum Capacity Btuh 8700 12500 11200 13600 15900
Heating at 5deg F Maximum Capacity Btuh 7061 10900 9194 12500 13022
Power Supply Phase Cycle Voltage 1-phase 60Hz 208 230V 4
Voltage
Indoor - Outdoor S1 - S2 AC 208 230V
Indoor - Outdoor S2 - S3 DC12-24V
Indoor - Remote Controller Wireless Type (Optional Wired Controller DC 12V)
Indoor Unit
MCA A 10
Fan Motor FLA 076
Airflow at Cooling (Lo-Med-Hi-Super HI-Powerful) 1
DRY (CFM) 145-170-237-321-399 162-226-339-381 145-170-237-321-399 162-226-381-410 205-272-335-420-533
WET (CFM) 109-134-201-286-364 144-202-307-343 109-134-201-286-364 144-202-350-367 170-237-300-385-498
Airflow at Heating (Lo-Med-Hi-Super HI-Powerful) 2
WET (CFM) 145-170-237-321-406 166-240-367-381 145-170-237-321-406 166-240-399-420 205-247 -304-367-463
Sound Pressure Level at Cooling (Lo-Med-Hi-Super HI-Powerful) 1
dB(A) 19-22-30-37-43 22-31-39-42 19-22-30-37-45 22-33-43-45 26-32-38-44-49
Sound Pressure Level at Heating (Lo-Med-Hi-Super HI-Powerful) 2
dB(A) 19-22-30-37-43 22-31-40-42 19-22-30-37-43 22-33-43-44 26-30-35-40-46
External Finish Color Munsell No 10Y 92 I 02
Dimension Unit
Wln 31-716 31-38 31-716 31-38 31-716
0 In 9-118 10-18 9-18 10-18 9-18
H In 11-58
Weight Unit Lbs 22 27 22 27 22
Field Drainpipe Size 00 In 58
Outdoor Unit
MCA A 12
MOCP A 15
Fan Motor FLA 050 056 050 056 050
Compressor
lVIodel (Type) DC INVERTER-driven DC INVERTER-driven Twin
Rotary DC INVERTER-driven DC IIWERTER-driven Twin Rotary
RLA 66 86 66 86 74
LRA 82 108 82 108 93
Airflow (CoolingHeating) CFM 11511225 1102 11187 12291172 1102 11187 12431229 Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(A) 46 48 49 48 49
Sound Pressure Level at Heating 2 dB(A) 50 49 51 49 51
External Finish Color Munsell No 3Y 78 11
Dimensions
Wln 31-12
0 In 11-114
H In 21-58
Weight Lbs 66 80 77 80
Remote Controller Type Wireless Remote (Optional Wired Controller)
Refrigerant
Type R410A
Charge Lbs Oz 112 29
Oil Type (fl oz) NE022 (108) NE022 (152)
Refrigerant Pipe Gas Side 00 In 38 12
Liquid Side 00 In 14 14
Refrigerant Pipe Length Height Difference (Max) Ft 40
Length (Max) Ft 65 I
Connection Method IndoorOutdoor FlaredFlared
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg e) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg e) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg e) Outdoor DB 47deg F(8deg e) WB 43deg F(6deg e) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg e) Outdoor DB 17deg F(-8deg e) WB 15deg F(-9deg e) 4 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice
12 +MITSUBISHI ELECTRIC LIMITED WARRANTY ISeven-year warranty on compressor Five-year warranty on parts
- shy(MSY(Z)-D30NA MODEL SHOWN)
Vl J
09 (I)
I
N o J (I)
s Vl N Vl
-0 (I) n 31 n OJ 0 o J V)
Model Name Indoor Unit MSZ-GE18NA MSZ-FE18N MSZ-GE24NA MSZ-D30NA MSZ-D36NA
Outdoor Unit MUZ-GE18NA MUZ-FE18rK MUZ-GE24NA MUZ-D30NA MUZ-D36NA Rated Capacity Btuh 17200 18000 22500 30700 33200
Capacity Range Btuh 3700-18700 8200-25200 8200-31400 9800-30700 9800-33200
Total Input W 1640 (240-2070) 1270 (570-2280) 1800 (570- 3580) 3850 (620-3850) 4360 (620-4360) Cooling 1
Energy Efficiency SEER 192 202 190 145
Moisture Removal Pintsh 46 27 27 99 11 3
Sensible Heat Factor 071 084 075 064 062
Rated Capacity Btuh 21600 21600 27600 32600 35200
Capacity Range Btuh 3500-25200 7500-29700 7500-36900 8700-34000 8700-36000 Heating at 47deg F 2
Total Input W 1900 (230-2680) 1540 (520-2240) 2340 (520- 3650) 3360 (520-3600) 3840 (520-4100)
HSPF (Region IV) BtuhIW 10 103 10 82
Rated Capacity Btuh 13400 11700 16000 19500 21800
Heating at 17deg F 3 Total Input W 1450 2180 3290 2400 2820
Maximum Capacity Btuh 17200 19300 24600 20800 22800 Heating at 5deg F
Maximum Capacity Btuh 13562 21 600 21160 16305 19090
Power Supply Phase Cycle Voltage 1 Phase 60Hz 208230V 4
Indoor - Outdoor S1-S2 AC 208 230V Voltage Indoor - Outdoor S2-S3 DC12-24
Indoor - Remote Controller Wireless Type (Optional Wired Controller DC12V) MCA A 10 Fan Motor FLA 076
DRY (CFM) 230-275-339-420-533 388-469-628-738 388-469-628-738 389-639-848 Airilow (Cool) (Lo-Med-Hi-Super HI-Poweriul) 1
WET (CFM) 194-240-304-385-498 347-420-562-661 347-420-562-661 350-576-763
Airilow (Heat) (Lo-Med-Hi-Super HI-Poweriul) 2 DRY (CFM) 230-275-339-431-512 388-469-628-738 388-469-628-738 445-639-848
Sound Pressure Level (Cooling) (Lo-Med-Hi-Super 28-33-38-44-49 34-41-49-53 34-41-49-53 32-42-49
HI-Poweriul) 1
Sound Pressure Level (Heating) (Lo-Med-Hi-Super dB(A)
Indoor Unit 28-33-38-43-48 32-41-49-52 32-41-49-52 34-42-49-49HI-Poweriul) 2
External Finish Color Munsell No 1 OY 9202
W In 31-716 43-516 46-116
Dimension Unit D In 9-18 9-38 11-58
H In 11-5 8 12-1316 14-38
Weight Unit Lbs 22 37 40
Field Drainpipe Size OD In 58
MCA A 14 171 21
MOCP A 15 20 25
Fan Motor FLA 093
Model (Type) DC INVERTER-driven Twin Rotary
Compressor RLA 100 129 16
LRA 125 161 20
Airilow CFM 1730 1659 17691 701 1941
Outdoor Unit Refrigerant Control Linear Ex~ansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(A) 54 55 56
Sound Pressure Level at Heating 2 dB(A) 56 55 57
External Finish Color Munsell No 3Y 7811
W In 33-116
Dimensions D In 13
H In 33-716 34-58 33-716
Weight Lbs 119 141
Remote Controller Type Wireless Remote (Optional Wired Controller)
Type R410A
Refrigerant Charge Lbs Oz 3 7 43 410
Oil Type (FI Oz) NE022 (152) FV50S (135) NE022 (29)
Gas Side OD 12 58In
Refrigerant Pipe Liquid Side OD 14 38
Height Difference (Max) 50
Length (Max) Ft
100 I Connection
Mpthon IndoorOutdoor Flared Flared
NOTESTest conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg C) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F (24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F(6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 17deg F(-8deg C) WB 15deg F(-9deg C) 4 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice LIMITED WARRANTY ISeven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 13
(SEZ-KD12NA MODEL SHOWN)
SEZ HEAT PUMP TAX
CREDIT
Model Name Indoor Unit SEZ-KD09NA4 SEZ-KD12NA4 SEZ-KD15NA4 SEZ-KD18NA4
Outdoor Unit SUZ-KA09NA SUZ-KA12NA SUZ-KA15NA SUZ-KA18NA Rated Capacity Btuh 8100 11500 14100 17200
Capacity Range Btuh 3800-10900 3800-13300 3800-17000 3800-19000
Cooling 1 Total Input W 670 920 1170 1380
Energy Efficiency SEER 15 16 155 175 Moisture Removal Pintsh 15 24 26 34 Sensible Heat Factor 080 076 080 079
Rated Capacity Btuh 10900 13600 18000 21600
Heating at 4YO F 2 Capacity Range Btuh 4800-14100 4800-16400 4800-21100 4800-24900
Total Input W 1020 1140 1500 1700 HSPF(lV) BtuhIW 100 Rated Capacity Btuh 6700 9000 11900 13100
Heating at 1 yo F 3 Rated Total Input W 810 920 1200 1350 Maximum Capacity Btuh 7300 9800 13700 15000
Power Supply Phase Cycle Voltage 1 Phase 60Hz 208 230V 4 Indoor - Outdoor S1 - S2 AC 208-230V
Voltage Indoor - Outdoor S2 - S3 DC 12-24V Indoor - Remote Controller See optional accessories chart (pg 26 and 27) MCA A 1 Fan Motor FLA 051 057 074
Airflow (Lo-Med-Hi) DRY (CFM) 194-247-317 247-317-388 353-441-529 423-529-635
WET (CFM) 174-222-285 222-285-349 317 -396-4 76 381-476-572 External Static Pressure 3 In wG 002-006-014-020 Sound Pressure Level dB(A) 23-26-30 23-28-33 30-34-37 30-34-38
Indoor Unit External Finish Galvanized-Steel Sheets
W In 31-18 39 46-78
Dimension Unit D In 27-916
H In 7-78
Weight Unit Lbs 42 50 54 62 Field Drainpipe Size 00 In 1-14
MCA A 12 14
MOCP A 15 Fan Motor FLA 050 093
Model DC Inverter DC Inverter Twin Rotary
I (Type)Compressor
RLA 66 74 10
LRA 82 93 125
Airflow (CoolingHeating) CFM 11511225 12291172 1 2431 229 17301659
Outdoor Unit Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(A) 46 49 54 Sound Pressure Level at Heating 2 dB(A) 50 51 56
External Finish Color Munsell No 3Y 7811
W In 31-12 33-16
Dimensions D In 11-14 13
H In 21-58 33-716
Weight Lbs 66 77 80 119 Remote Controller Type See optional accessories chart (pg 26 and 27)
Type R410A
Refrigerant Charge Lbs Oz 116 2 9
Type (fl Oil
oz) NE022 (108)
Refrigerant Pipe Gas Side OD In 38 Liquid Side 00 In 14
Refrigerant Pipe Height Difference (Max) Ft 40 Length Length (Max) Ft 65
Connection IndoorOutdoor FlaredFlared
Method
316
NE022 (152)
12
50
100
I
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg C) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F(8deg C) WB 43deg F(6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 17deg F(-8deg C) WB 15deg F(-9deg C) 4 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
14 MITSUBISHI ELECTRIC
SEZ STATIC PERFORMANCE CURVES (SEZ-KD12NA4 MODEL SHOWN)
SEZ-KD09NA4 SEZ-KD09NA4 (External static pressure O06[inwG]) 208230V 60Hz
[020] V L
5 [016
~l [0 12
]
SEZ-KD09NA4
~ ltij
~ [008
Jj
]
]
[004J ~
V V Middle
Low
V
19h
Rated point
1
o [141] [176J 1212) )247] [282J [318]
Airll ow rat e [CFM)
SEZ-KD12NA4 (External static pressure O06[inwG]) 208230V 60Hz
[020
5 [016
]
]
[353J
Limit
]
~ V
~ [ [0 12
u ltijJ[008
[004
]
_V ]~ Low
V
k-iddle
Rated POint
o [212) [247] [2 82] [318] [353] [388]
Airtlow rate [C FM]
SEZ-KD1SNA4 (External static pressure O06[inwGl) 208230V 60Hz
[424)
1020]
5 [016
~ ~ [012
~ ltij
~ [008
Jj
J
)
]
[004 ]
o
VV V [ Low
VV
vV High
Middle
I Rated point
[282] [318) [353] [388] [424] [459] [494] [530] [565J
Airllow rat e [CFM]
SEZ-KD18NA4 (External static pressure O06[inwG]) 208230V 60Hz
50 10 20]
] 40
5 [016
s 30 [ (012 )
ltij 20 ~ [008 )~Jj
10 [004]
V
Low
v Limit
rIV High
V [ Middle
~
1
Rated point
f318) [353) [388] [424] [459] [494] [530] [565] [600] [636] [671 )
Airllow rate [CFM]
(External static pressure O14[inwG]) 208230V 60Hz 80
[0 32
70 [028
5 60 [024
20 [0 08
10 [004
]
]
J
]
]
J
]V
]
U~it
V
k
High
~V Rated POI~1 V Middle Low
~
o [141] [1 76] 12121 )247J [282] [318]
Airtlow rate [CFM)
SEZ-KD12NA4 (External stat ic pressure O14[inwG]) 208230V 60Hz
[032]
[028J
5
[353]
J
~ [024
-~ [020] V-is
J V Il Hi9h Rated point
[016
~ ]
V V1 Middle
~ [012
[008]~
[004)
o [212)
[247)
SEZ-KD1SNA4
Low r
[282] [31 8) [353]
Airllow rale [CFM]
[388]
(External static pressure O14(inwG]) 208230V 60Hz
[032J
[424
]
2 V[028
5 [024]
V-i
] V High i [020
] K
Middle Rated point [0 16
g ]
~ -
QJj [0 12
J Low
[008
] I
~
[004
o [282J [318) [353J [388J [424) [459] [4 94] [530) [565)
Airt low rate [CFM]
SEZ-KD18NA4 (External statiC pressure O14(inwG]) 208230V 60Hz
1032
1028
~ 1024
-~ [0 20
is (0 16 ltij E ~ [012
(008
(004
o
I
]
]
)
]
)vlt ]
]
~ V
VV
Low
Limit
V
Ji9h
Middle l
Rated point
1 t
1
~ [318] [353] [388] [424] [459) [4 94] [530) [565) [600] [636] [671)
Airllow rate [CFM]
(External static pressure O20(inwG]) 208230V 60Hz
[032 ]
[028 J
5 [024
~ [020
is [016
1 [012Jj
[008
[004
J
]
]
] )
]
V Low
umz V High
~V
Rated point
Middle
1
[141] [176] [212) [247) [282) [318) [353J
Airtlow rat e [CFM]
SEZ-KD12NA4 (External static pressure O20(inwG]) 208230V 60H z
[032 ] LLimit
)
[0 28
5 ]
V
[024 -~ [020] V Rated point
Highis ~
) V
bull Middle
]~V I
[016
~ ~ [012
] Low
[008
]
[0 04
o [212) [247] [282] [318] [353] [388] [424]
Airllow rate [CFM]
SEZ-KD1SNA4 (External static pressure O20(inwG]) 208230V 60Hz
80 [032 ]
70 [0 28
~ [ O~~ -
ltij
E 30 ~ [0 12
20 [008
10 [004
o
)
J
]
]
JV
J
J
Limit V
LV High
V ~
K Rated point
Middle
VV 1gt
Low
I-
~ [282) [318) (353] (388) (424) 1459] [494] 15301 [565)
Airtlow rate [CFM]
SEZ-KD18NA4 (External static pressure O20[inwG]) 208230V 60Hz
[032
[028
~ [024sect
I [020
~ [016
~ Jj [0 12
[008
[004
o
]
)
]
]
]
~ )
]
]
1V
V 1
V
Low
1 limit
~~~ I ~~ High
~ R~ted pOini
Middle
1 1 -
[31 8) [353] [388] [424) [459] [494] [530] (565) [600] (636) [671J
Airllow rate [CFM)
Vl ~ ca (I)
I
N o ~ (I)
Vl m N Vl
-0 (I) n 3-i n QJ ~ o ~ tn
Note ESP 20S230V 60 Hz See manual for Static Performance Curve including 002 in WG
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts ~MITSUBISH[ ELECTRIC 15
SLZ HEAT PUMP (SLZ-KA12NA MODEL SHOWN)
Model Name Indoor Unit SLZ-KA09NA SLZ-KA12NA SLZ-KA15NA
Outdoor Unit SUZ-KA09NA SUZ-KA12NA SUZ-KA15NA Rated Capacity Btuh 8400 11100 15000
Capacity Range Btuh 3100-10900 3100-13300 3100-22200
Cooling 1 Total Input W 700 920 1460
Energy Efficiency SEER 15 154 16 Moisture Removal Pintsh 12 23 45 Sensible Heat Factor 080 076 080
Rated Capacity Btuh 10900 13 600 18000
Heating at 4r F 2 Capacity Range Btuh 3100-14100 3100-17100 3100-17100 Total Input W 930 1180 1950 HSPF (IV) BtuhIW 96 Rated Capacity Btuh 6200 8300 10200
Heating at 17deg F 3 Rated Total Input W 740 930 1310 Maximum Capacity Btuh 8300 10200 12000
Power Supply Phase Cycle Voltage 1 Phase 60Hz 208 230V 4 Indoor - Outdoor S1 - S2 AC 208-230V
Voltage Indoor - Outdoor S2 - S3 DC 12-24V
Indoor - Remote Controller See optional accessories chart (pg 26 and 27) MCA A 1 Fan Motor FLA 023 028 028
Airflow (Lo-Med-Hi) DRY (CFM) 280-320-350 280-320-390 280-320-390
WET (CFM) 250-290-320 250-290-350 250-290-350
Sound Pressure Level dB(Al 29-32-38 30-34-39 31-35-40
Indoor Unit External Finish Galvanized-Steel Sheets Grille Munsell 64Y 8904
W In 22-7 16 (25-58)
Dimension Unit (Grille) D In 22-716 (25-58
H In 8-316 (1316)
Weight Unit (Grille) Lbs 36 (7) Field Drainpipe Size 0 0 In 1-14 MCA A 12 MOCP A 15 Fan Motor FLA 050
Model (Type) DC INVERTER-driven DC INVERTER-driven
Compressor RLA 66
LRA 82
Airflow (CoolingHeating) CFM 11511225 1 229 1 172
Outdoor Unit Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(AJ 46 49 Sound Pressure Level at Heating 2 dB(AJ 50 51
External Finish Color Munsell No 3Y 781 1
W In 31 shy12
Dimensions 0 In 11-14
H In 21-58
Weight Lbs 66 77
~e R410A
Refrigerant Charge Lbs Oz 1 16
Oil Type (fl oz) NE022 108)
Refrigerant Pipe Gas Side 0 0 In 38 Liquid Side 00 In 14
Height Difference (Max) Ft 40 Refrigerant Pipe Length
Length (Max) Ft 65
Connection Method IndoorOutdoor FlaredFlared
29
Twin Rotary 74
93
12431 229
80
NE022 l152) 12
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg C) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F(8deg C) WB 43deg F(6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 17deg F(-8deg C) WB 15deg F(-9deg C) 4 Indoor units receive power from outdoor units through field-supplied interconnectedwiring Specifications are subject to change without notice
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
16 MITSUBISHI ELECTRIC
MHK1 WIRELESS REMOTE CONTROLLER KIT Exclusive for INVERTER-driven Mr Slimreg Systems VlWireless Technology a J
JMITSUBISHI ELECTRIC
Wireless Receiver
MHK1 Kit includes
09 mMRCH1 WIRELESS REMOTE CONTROLLER I Nbull Backlit easy-to-read display o
bull Dual setpoint control with system changeover J m
bull Enabled with RedLlNKTM reliability
bull Compatible with MCCH1 Vl Portable Central Controller m
N bull Installs Anywhere Vl
MFH1 WIRELESS RECEIVER N Vlbull Required for MRCH1 Wireless
CRemote Controller m bull Enabled with RedLiNK reliability n
31 n OJ o J en
SEZ and SLZ 11 systems with SUZ outdoor unit
Function Description
ONOFF OnOff operation for a single indoor unit
Operation Mode Cool I Drying I Auto I Heat I Fan only Available operation modes dependant on connected system
Temperature Setting Set temperature from 50degF - 8rF depending on operation mode and connected system
System Changeover Deadband Value 2-8degF
Schedule Operation 5-25-1-1
Fan Speed Setting HiMid-2Mid-1 IlowlAuto Available fan speed settings dependant on connected system
Air Flow Direction Setting Air flow angles 100deg - 80deg - 60deg - 40deg and oscilate Available air flow direction settings dependant on connected system
PermitProhibit Function Individual prohibit operations for each remote controller function (ONI OFF Set Temperature and Operation Mode)
Space Temperature Displays the measured space temperature
Error Indication Displays error code
Display Outside Temperature and Humidity
Requires optional MOS1 Outside Air Sensor
Dimensions - ryv x D x H) Remote Controller 5-316 x 1-12 x 3-916 Receiver 3-14 x 1-516 x 6-716
Operating Ambient Temperature Remote Controller 32 - 120degF Receiver -40 - 165degF
Operating Ambient Humidity Remote Controller 5 - 90 RH (non-condensing) Receiver 5 - 90 RH (non-condensing)
Power Supply 2 AA batteries
MRCH1 MIFH1 MRC1
Wireless Wall-Mounted Remote Controllers Wireless Receiver Cable
Accessories MCCH1 MOS1
Portable Central Controllers Outside Air Sensor
MITSUBISHI ELECTRIC 17
MULTIPLE ROOMS WITH INDIVIDUAL CONTROL FROM A SINGLE SYSTEM Enjoy ideal levels of comfort in the rooms you use most with our multi-room system Each room (zone) operates independently People in different rooms - the kitchen master bedroom or living room - can enjoy temperature settings that make each of them most comfortable
If you re looking for a complete comfort solution for several different rooms the MXZ multi-room system is the right choice The system is flexible enough to conform to a particular cooling and heating need and offers numerous different indoor unit combinations In addition up to eight indoor units can be connected to one outdoor unit Now with a SEZ horizontal ducted unit and a MFZ floorshystanding unit homeowners can enjoy an even greater range of zoning options provided by an MXZ system
An MXZ multi-room system is an excellent choice for supplementing capacity to a current system conditioning newly furnished spaces or new additions and replacing a system within a home Homeowners can also benefit from lower energy costs year-round while staying comfortable thanks to Mitsubishi Electrics energy-efficient technologies that are a part of every system that we make
To add to the level of energy efficiency the MXZ -2B20NA and MXZ -3B24NA systems qualify for both ENERGY STARreg and the federal tax credit (See details on page 21 for applicable indoor unit combinations)
At right a single level home with several system types represented (For illustrative purposes only)
MFZ Floor-Standing Indoor Units for MXZ Heat Pump Systems
Floor-standing indoor unit mounts three inches above the floor and has front panel access to the filter for ease of cleaning
The MFZ units provide energy-efficient solutions to provide personalized comfort for difficult areas that may be smaller or dont have usable space on the walls
MFZ units on MXZ systems include the following features bull Top and bottom discharge vanes bull Hot-start technology bull Quiet operation bull Wireless remote control (optional wall-mounted controller)
18 MITSUBISHI ELECTRIC
MSZ Wall-Mounted Indoor Units for MXZ Heat Pump Systems
Providing a wide range of cooling and heating capacities each wall-mounted indoor unit mounts high on a wall and connects to a branch box or the outdoor unit by a refrigerant line run via a 3 hole The MSZ units provide highly efficient solutions to cooling and heating needs and provide personalized comfort for the individual zones in which they are installed
MSZ units on MXZ systems include the following features bull Sleek flat panel design bull Hot-start technology bull Quiet operation bull i-seeM sensor technology (MSZ-FE0912NA models only) bull Enhanced filtration system (MSZ-FE0912NA models only) bull Wireless remote control (optional wired wall-mounted controller)
SLZ Ceiling-Recessed Indoor Units for MXZ Heat Pump Systems
The new SLZ-KA ceiling casette systems offer a wide air-flow pattern for better air distribution
offered to your customers Installation can be done in a hard ceiling (with a access panel for servicing) or placed into a 2x2 drop ceiling With a built-in drain lift mechanism for condensate
removal and a 4 ventilation air intake knockout option the SLZ is ready to handle a variety of installation needs
SLZ units on MXZ systems include the following features bull Wide air-flow pattern for better air distibution bull 4 ventillation air intake knockout bull Built-in condensate lift mechanism bull Wireless RedLlNKTM remote controller
SEZ Horizontal Ducted Indoor Units for MXZ Heat Pump Systems
SEZ ducted units can provide split air-conditioning system advantages with the added benefit of being concealed to provide virtually no visual footprint within the conditioned space other than a register and grille for the air to flow With the use of short run ductwork these units can provide comfort to a single room that needs air dispersed evenly throughout the space unusually shaped rooms and adjacent rooms
The SEZ unit on MXZ systems include the fOllvowin fatures _
g~e~~~~==Zl[bull Concealed design for short-run ductwork bull Quiet operation bull Built-in condensate lift mechanism
JMITSUBISHI ELECTRIC 19
s c t
I
N o J ro o ltro ~ ro ~
DIAMOND COMFORT MXZ MULTI-ZONE SYSTEMS MXZ-B Series multi-zone systems provide personalized comfort control and energy efficiency in up to eight rooms with only a single outdoor unit The MXZ-B Series system features include
bull Individual zone control bull Mix and match flexibility of indoor unit styles and combinations bull A wide range of indoor unit capacities that match the room size and requirements bull Flexible design options to tackle the most challenging multi-room installations bull Efficient systems including three systems [mxz series] that meet energy starltID and
federal tax credit requirements bull Simple quick and cost-effective installation keeps install costs down on new construction
and disruption to a minimum on renovations and refits
Efficiency and performance ratings depend on the number style and capacity of the indoor units installed with each Multi-Zone System
MXZ -2 B20 NA - 1 (2 1 ) MXZ -3 B24 NA (2 13 1) Ou tdoo r Unit Outdoor Uni t
MSZ-GE09NA Indoor Units
SEZ-KD12NA Indoor Unit
MSZ- GE06NA
~~~~li
(At least two indoor units MSZ-GE06NAIndoor Unit must be installed) Indoor Unit
(Two indoor units must be installed )
MXZ -3 B30 NA (2 1 3 1) Outdoor Unit
SEZ-KD12NA Indoor Unit
~~~i
(At least two indoor units MSZ-GE06NA must be installed)
Indoor Unit ~
MFZ- KD12NA Indoor Unit
MXZ-8B48NA (2 1-8 1) Outdoor Unit
(At least two indoor units
must be installed)
(At least two indoor units must be installed)
MFZ-KD09NA Indoor Units
MSZ-GE09NA Indoor Units
SEZ-KD12NA Indoor Unit
MSZ INDOOR UNIT
MSZ-FE18NA
PEAD HORIZONTAL -DUCTED INDOOR UNIT
PEAD-A24AA
MSZ INDOOR UNIT SEZ HORIZONTAL-DUCTED MSZ-FE18NA
INDOOR UNIT MFZ FLOOR-STANDING SEZ-KD18NA INDOOR UNIT
MFZ-KA12NA
20 AMITSUBISHI ELECTRIC
MULTI-ROOM MXZ-8 INVERTER HEAT PUMP R
Model Name Outdoor Unit MXZ-2B20NA-1 5 MXZ-3B24NA 6 MXZ-3B30NA MXZ-4B36NA 7
Indoor Unit
Cooling 1 Non-ductedl Ducted
Rated Capacity Btuh 1800020000 2200023600 28400127400 3540034400
Capacity Range Btuh 7800-20000 12600-25500 12600-28400 12600-36400
Total Input W 2190 (630-219QL 2460 (1000-2950) 3330 l1 000-3330) 3 940 (1 000-4020)
Heating at 4JO F 2 Non-ductedl Ducted
Rated Capacity Btuh 2200022000 2500024600 2860027600 3600034400
Capacity Range Btuh 8500-25500 11400-30600 11 400-36000 11400-43000
Total Input W 2620 (520-2620) 1900 (740-2600) 2220 (740-2820) 3100 (740-3940)
Heating at 1JO F 3 Non-ductedl Ducted
Rated Capacity Btuh 1250012500 1400014000 1600015100 2220020300
Rated Total Input W 13501430 13801570 21202 140 24302340
Maximum Capacity Btu h 1450014500 1880017000 1880018000 2460025400
Maximum Total Inl2ut W 15001590 21202230 21202140 33403450
Power Supply Phase Cycle Voltage 1-phase 60Hz 2081 230V 8
Voltage Indoor shy Outdoor S1 - S2 AC 2081 230V
Indoor shy Outdoor S2 - S3 DC12-24V
Outdoor Unit 4
MCA A 15 19
MOCP A 20
Fan Motor FLA 096 093
Compressor
Model (Type)
DC INVERTER-driven Twin Rotary
RLA 101 11 144
LRA 15
Airflow (CoolingHeating) CFM 14851 640 20681605 13651605 20682068
Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1
dB(A) 49 54 49 54
Sound Pressure Level at Heating 2
dB(A) 51 49 57
External Finish Color Munsell No 30Y 781 1
Dimensions
W In 33-116 35-716
D In 13 12-58
H In 27-1516 35-7116
Weight Lbs 130 150 153
Indoor Unit No of Units 2 23 23 234
Remote Controller Type Associated with the Indoor Unit
Refrigerant
Type R410A
Charge Lbs Oz 515 7 11 813
Oil Type (fl oz)
NE022 (237) NE022 (294)
Refrigerant Pipe Gas Side 00 In AB 38 A 12 BC 38 A 12 BCD 38
Liquid Side 00 In 14
Refrigerant Pipe Length Height Difference (Max) Ft 4933 9
Length (Max) Ft 164 (A+B) 230 (A+B+C) 230 (A+B+C+D)
Connection Method IndoorOutdoor FlaredlFlared
Compatible with the MSZ-A MSZ-GA MSZ-FD MSZ-FE MSZ-GE MFZ-KA and SEZ-KD series indoor units (PLA-18 amp PCA-24 on the MXZ-MXZ-3B PLA-24 amp PCA-24 on the MXZ-4B)
NOTES Test conditions are based on AHRI 210240 One indoor unit is turned off during low-speed testing under the new test conditions Systems actually exhibit higher energy efficiencies during normal operation
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F (35deg C) WB 75deg F (24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F (6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 600 F (160 C) Outdoor DB 17deg F (_80 C) WB 150 F (_90 C) 4 Refer to pages 12 and 13 for Indoor Unit specifications 5 Data from combination of two Indoor Units 9000 Btuh (non-ducted) or one 9000 Btuh and one 12000 Btuh (ducted) 6 Data from combination of two Indoor Units 6000 Btuh and one 9000 Btuh (non-ducted) or three 9000 Btuh (ducted) 7 Data from combination of four Indoor Units 9000 Btuh (non-ducted and ducted) 8 Indoor units receive power from outdoor units through field-supplied interconnected wiring 9 49 Applies to installations where the outdoor unit is installed below the indoor unit
Power factor equals 97 percent
Specifications are subject to change without notice
MULTI-ZONE ENERGY STAR AND TAX CREDIT SYSTEMS
Model Indoor Unit Combinations SEER HSPF
MXZ-2B20NA-1 2 x MSZ- GE09NA 18 8 9
MXZ- 3B24NA 2 x MSZ- GE06NA 1 x MSZshy GE09NA
17 5 9 3
MXZ- 3B24NA 2 x MSZ-GE06NA 1 x MSZ- GE12NA
17 5 93
For more details on all ENERGY STAR and tax credit systems go to wwwmitsubishicomfortcomtaxcredit
See page 25 for additional info on efficiency
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 21
MXZ-8B48NA THE ULTIMATE ZONING SOLUTION
The Mitsubishi Electric MXZ-S84SNA eight-zone unit As a member of the expanding MXZ-B Series of multi-zone systems the MXZ-8B outdoor unit incorporates branch boxes to connect up to eight indoor units MXZ- 8 B48 NA (2 1 - 8 1 )
Outd oor Uni t The INVERTER-driven compressor at the heart of the MXZ-8B -~-- shy
outdoor unit provides variable capacity control allowing the system to adjust to the specific demands of the interior space ~ as needed not the hard start and stop of a traditional system I[iDA Jinstalled in most US homes
The MXZ -8B48NA has only one port on the outdoor unit for two insulated refrigerant lines which run into the home or business to connect to a branch box or boxes From the branch box(es) gas and liquid refrigerant piping run to each of the indoor units The LEV in the branch box(es) controls the refrigerant flow as the load of each zone changes
Through the branch box(es) (the PAC-AKA31 BC three-port andor the PAC-AKA51 BC five-port) the system can connect from two indoor units up to eight indoor units depending on application requirements
The flexibility of the system doesnt stop there The MXZ-8B48NA has rated capacities of 48000 Btuh for cooling and 54000 Btuh for heating System operation however can range from a minimum 12000 Btuh to a maximum 54000 Btuh in cooling and a maximum of 60000 Btuh in heating This type of performance supports a large variety of applications
The MXZ-8B48NA allows for further flexibility because it supports a connected indoor unit capacity from 22 to 130 or 12000 Btuh to a maximum 70200 Btuh depending on diversity
Connectable Indoor Units General Features bull Four-ton outdoor unit can support up to
eight indoor units using branch boxes bull Wide variety of indoor unit styles
-=--_-=-----= - - J _ 1
including wall-mounted floor-standing MSZ-FE09 12 18NA MSZ-GE06 09 12 15 18 24NA ceiling-cassette ducted
bull Individual control up to eight (8) zones using wired or wireless controls
bull Advanced microprocessor control bull Auto restart following a power outage bull Self-check function offering SEZ-KD09 1215 18NA PEAD-A24AA
integrated diagnostics ~--- Jbull Limited warranty five years on parts and
defects and seven years on compressors
SLZ-KA09 1215NA MFZ-KA09 12 18NA
22 MITSUBISHI ELECTRIC LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
I
RMULTI-ROOM MXZ-8 INVERTER HEAT PUMP
Model Name Outdoor Unit MXZ-BB4BNA Cooling 1 Rated Capacity
Non-ducted Rated Total Input Ducted
Maximum Capacity
Rated CapacityHeating at
Rated Total InputIndoor Unit 4JO F 2 Non-
ductedDucted Maximum Capacity
Rated Capacity Heating at
Rated Total InputlJO F 3 Non-ductedDucted Maximum Capacity
Power Supply Phase Cycle Voltage
Indoor - Outdoor Sl - S2 Voltage
Indoor - Outdoor S2 - S3
MCA
Recommended FuseBreaker Size
Fan Motor
Compressor
Airflow (CoolingHeating)
Refrigerant Control
Outdoor Unit Sound Pressure Level at Cooling 1
Sound Pressure Level at Heating 2
External Finish Color
Dimensions
Weight
Total Capacity 22-130
Indoor Unit ModelQuantity
Remote Controller Type
Type
Refrigerant Charge
Oil
Gas Side OD Refrigerant Pipe
Liquid Side OD
Height Difference (Max)
Maximum Distance between (Outdoor unit and farthest indoor unit)
Refrigerant Pipe Length Maximum Pipe Length -Branch box to Indoor Unit
Total Maximum line length between Branch Box and All Connected Indoor Units
Total Length (Max)
Connection Method IndoorOutdoor
Includes both branch boxes if there are two
Branch Boxes (At least one branch box required)
Btuh
W
Btuh
Btuh
W
Btuh
Btuh
W
Btuh
A
A
Type x Quantity
Motor Output (kW)
Model (Type)
Motor Output (kW)
CFM
dB(A)
dB(A)
W In
D In
H In
Lbs
Btuh
Lbs Oz
Type (fl oz)
In
In
Ft
Ft
Ft
Ft
Ft
4800048000
57806470
54000
5400054000
48205270
60000
3300034700
29503390
3660036550
1 Phase 60Hz 208 230V
AC 208-230V
DC12-24V
32
40
Propeller x 2
0086 + 0086
DC INVERTER-driven Scroll
29
3530
Linear Expansion Valve
54
55
Munsell No 3Y 78 11
37-716
13+1-3 16
53-3 16
278
12000 - 70200
600 - 24000 2-8
Associated with Indoor Unit Model
R410A
18 112
FV50S (73)
58
38
6698 4
230
49
197
377
FlaredFlared
Compatible with the MSZ-A MSZ-FO MSZ-FE MSZ-GE MFZ-KA SEZ-KD PLA and PEAD series indoor units
NOTES Test conditions are based on AHRI 210240 One indoor unit is turned off during low-speed testing under the new test conditions Systems actually exhibit higher energy efficiencies during normal operation
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F (35deg C) WB 75deg F (24deg C)
2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 4]0 F (8deg C) WB 43deg F (6deg C)
3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 17deg F (-8deg C) WB 15deg F(-9deg C)
4 66 applies to installations when the outdoor unit is installed below the indoor unit
Power factor equals 97 percent
Specifications are subject to change without notice
Note Maximum installed capacity is the maximum total of all connected indoor units NOT the maximum capacity produced
Only a single Lineset is needed from the outdoor unit to branch box
See page 25 for MXZ-B information on efficiency
Required Branch Boxes for MXZ-SB4BNA (Maximum of 2 branch boxes can be connected to one outdoor unit requires joint MSDD-50AR-E or MSDD-50BR-E)
s c d N o J ro Vl
0 ro n 3i n OJ d o J U)
PAC-AKA51 BC Branch Box
PAC-AKA31 BC Branch Box LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 23
MSZ WALL-MOUNTED INDOOR UNITS (FOR MXZ-8 OUTDOOR UNITS)
R
(MSZ-GE12NA MODEL SHOWN)
-000 IIIIIII 9000 9000 12000 12000 14000 17200
Heating at 4r Rated Capacity Btuh 7200 10900 10900 14400 13600 18000 21600
F2 Power Supply I Phase Cycle Voltage J -phase 60Hz 208 230V 3
Iindoor Outdoor S1 S2 AC 208 230V
Iindoor Outdoor S2 S3 DC12-24V Voltage
Iindoor Remote vomr Iller Wireless Type (Optional Wired vomroller DC 12V)
IMCA A 10 IFan Motor FLA 076
DRY 162-226shy145-170shy
162-226shy205-272shy 230-275shy
Airflow at Cooling (CFM)
145-170-237-321-399 339-381
237 -321shy381-410
335-420shy 339-420shy(Quiet-Lo-Med-Hishy 399 533 533 Super Hi or Lo-Med-
WET 144-202shy109-134shy
144-202shy170-237shy 194-240shy
Fan Hi-Powerful)1 (CFM)
109-134-201-286-364 307-343
201-286shy350-367
300-385shy 304-385shy364 498 498
Airflow at Heating 145-170shy 145-170shy 145-170shy 205-247shy 230-275shy
(Quiet-Lo-Med-Hi- WET 233-321shy 237-321shy
166-240shy237-321shy
166-240shy304-367shy 339-431shy
Super Hi or Lo-Medshy (CFM) 406 406
367 -381 406
399-420 463 512
Hi-Powerful) 2 Sound Pressure Level at Cooling
19-22-30shy 26-32-38shy 28-33-38shy(Quiet-Lo-Med-Hi-Super Hi or Loshy dB(A) 19-22-30-37 -43 22-31-39-42
37-45 22-33-43-45
44-49 44-49Med-Hi-Powerful) 1
Sound Pressure Level at Heating 19-22-30shy 26-30-35shy 28-33-38shy
(Quiet-Lo-Med-Hi-Super Hi or Loshy dB(A) 19-22-30-37 -43 22-31-40-42 37-43
22-23-43-44 40-46 43-48
Med-Hi-Powerful) 2
I External Finish Color Munsell No 10Y 92 02
IWln 31 middot716
Dimension Unit 10 In 9 18 10-18 9middot18 10-18 9-18
IH In 11-58
I Weight Unit ILbs 22 27 22 27 22 I Field Drainpipe ~D lin 58 Remote Con-
Type Wireless Remote (Optional Wired Controller) troller
ITvpe B41QA Refrigerant ~s$ideOD lin 38 Pipe I Liquid Side 00 In 14
Connection IndoorOutdoor FlaredFlared
Method
1~
II 18000 22500
21600 27600
388-469shy 38$-469shy628-738 628-738
347-420shy 347-420shy562-661 562-661
388-469shy 388-469shy628-738 628-738
34-41-49-53 34-41-49-53
32-41-49-52 32-41-49-52
43-516
9-38
12-1316 37
58 38
MXZ-2B20NA is also compatible with the MSZ-A and MSZ-FD series indoor units NOTES Test conditions are based on AHRI 210240
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F(6deg C) 3 Indoor units receive power from outdoor units through field-supplied wiring
Specifications are subject to change without notice LIMITED WARRANTY Seven-year warranty on compressor Five-year warranty on parts For data on specific indoor unit combinations see page 21
SEZ DUCTED INDOOR UNIT (FOR MXZ-8 OUTDOOR UNITS)
I
Notes 1 Cooling-Indoor DS 80deg F(267deg C) WS 67deg F(194deg C) Outdoor DS 95deg F (35deg C) WS 75deg F(239deg C)
2 Heating-Indoor DS 70deg F(211 deg C) WS 60deg F(156deg C) Outdoor DS 47deg F (83deg C) WS 43deg F(61 deg C)
3 External static pressure is factory set to 006 WGAdjustable via the
1---------t---+-----L-------------1~---__I PAR-21MAA
1--_____----__________+-____---L____----~_____________1 4 Indoor units receive power
jE~~~~-------------r----1-----~-~~~~~~~~-----___1 from outdoor units through fieldsupplied interconnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven-year warranty on compressor Five-year
1---------------------+---+------------------------1 warranty on parts
~--__I_~----------+-------~l----------I For data on specific indoor unit combinations see page 21 - 23
I--~------+~-----------~----------r_------------I
- Reference page 17 for SEZ static performance curves
24 MITSUBISHI ELECTRIC
25-30-35-40 26-31-36-41 35-38-42-46
25-30-35-40 28-31-36-41 35-38-42-47
MFZ FLOORLOW WALL INDOOR UNIT (FOR middotMXZ-8 OUTDOOR UNITS)
------shy
-==
Airflow at Heating (CFM) 177-198-219-332 184-201-219-335 261-275-297-434
Voltage
Fan
Airflow at Cooling (Lo-Med-Hi-Super Hi)1
169-205-251-314 251-279-325-394
163-197-241-303 170-207-252-309 241-269-313-379
(Lo-Med-Hi-Super Hi) 2
SLZ CEILING-RECESSED INDOOR UNIT (FOR MXZ-8 OUTDOOR UNITS) EFFICIENCY RATINGS
Voltage
Fan
Galvanized-steel SheetsMunsell 64Y 89 04
Refrigerant Pipe
Model Indoor Unit Type SEER HSPF
MXZ-2B20NA-1
Non-dueted 18 89
Dueted and Non-dueted 1675 87
Dueted 155 85
MXZ-2B20NA-1 ENERGY STAR amp
TAX CREDIT 2 x MSZ-GE09NA 18 89
MXZ-3B24NA
lJon-dueted 175 93
Dueted and Non-dueted 1625 89
Dueted 150 85
MXZ-3B24NA ENERGY STAR amp
TAX CREDIT
2 x MSZ-GE06NA 1 x MSZ-GE09NA
175 93
MXZ-3B24NA ENERGY STAR amp
TAX CREDIT
2 x MSZ-GE06NA 1 x MSZ-GE12NA
175 93
MXZ-3B30NA
Non-dueted 175 105
Dueted and Non-dueted 16 100
Dueted 145 95
MXZ-4B36NA
Non-dueted 18 93
Dueted and Non-dueted 16 5 92
Dueted 150 9 0
MXZ-BB4BNA
Non-dueted 15 87
Dueted and Non-dueted 14B B8
Dueted 147 89
Connection IndoorOutdoor FlaredFlared
Method
Notes 1 Cooling-Indoor DB 80deg F(267deg C) WB 67deg F(194deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(239deg C) 2 Heating-Indoor DB 70deg F(21 1 deg C) WB 60deg F(156deg C) Outdoor DB 47deg F(83deg C) WB 43deg F(61 deg C) 3 Indoor units receive power from outdoor units through field supplied interconnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 25
Notes 1 Cooling-Indoor DB 80deg F(267deg C) WB 67deg F (194deg C) Outdoor DB 95deg F (35deg C)WB 75deg F (239deg C)
2 Heating-Indoor DB 70deg F(211deg C) WB 60deg F (156deg C) Outdoor DB 47 F (83deg C) WB 43deg F (61 deg C)
3 Indoor units receive power from outdoor units through field supplied interco(lnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven -year warranty on compressor Five-year warranty on parts
Presently there is no 1 1 system with the MFZ indoor unit
s c
N o J ro Vl
C ro n ~ n OJ t o J V)
M-SERIES RATING CONDITIONS
INDOOR INTAKE AIR TEMPERATURE
OUTDOOR INTAKE AIR TEMPERATURE
COOLING
MAXIMUM
95degF DB 71 degF WB (MU SUZ MXZ-2B20-13B243B304B36) 90degF DB 73degF WB (MUZY-GE MUZ-FE MUzy-D)
115degF DB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B24 3B304B368B48)
MINIMUM 67degF DB 57degF WB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B201 3B243B304B36)
14degF DB (MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B24 3B304B36) 23degF DB (MXZ-8B48) 6rF DB (MU)
MAXIMUM 80degF DB 6rF WB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B243B304B36)
75degF DB 65degF WB (MUZY-GE MUZY-GA24 MUZ-FE SUZ MXZ-2B20-1 3B243B304B36) 70degF DB (MXZ-8B48)
HEATING
MINIMUM 70degF DB 60degFWB (MUZ-GE MUZ-GA24 MUZ-D MUZ-FE SUZ MXZ-2B20-1 3B243B304B36)
-13degF DB -15degFWB (MUZ-FE) -4degF DB -5degF WB (SUZ MUZ-GE) 5degF DB 4degF WB (MUZ-GA24 MXZ-8B48NA) 6degF DB 5degF WB (MXZ-2B20-1 3B24 3B304B36) 14degF DB 13degFWB (MUZ-D)
MU units operate at intake air temperature down to 10deg Fwith the addition of an ICM-326HM-1 low temperature control
REFRIGERANT TUBING SETS
OPTIONAL ACCESSORIES
REFRIGERANT LINE LENGTH FLARE FLARE _INDOOR UNIT OUTDOOR UNIT
MS-A09WA MU-A09WA 35 MS-A12WA
65 MU-A12WA 35
MSY-GE09NA 65
MUY-GE09NA 40
MSY-GE12NA
65
MUY-GE12NA 65 40
MSY-GE15NA MUY-GE15NA 40
MSY-GE18NA
65
MUY-GE18NA 100 50
MSZ-GE09NA MUZ-GE09NA 65 40
MSZ-GE12NA MUZ-GE12NA 40
MSZ-GE15NA
65
MUZ-GE15NA 40
MSZ-GE18NA
65
MUZ-GE18NA 100 50
MSY-GE24NA MUY-GE24NA 100 50
MSZ-GE24NA MUZ-GE24NA 100 50
MSY-D30NA MUY-D30NA 100 50
MSZ-D30NA MUZ-D30NA 50
MSY-D36NA
100
MUY-D36NA 50
MSZ-D36NA
100
MUZ-D36NA 100 50
MSZ-FE09NA MUZ-FE09NA 40
MSZ-FE12NA
65
MUZ-FE12NA 40
MSZ-GE06091215NA MSZ-FE0912NA
65
MXZ-2B20NA-1 164 4933MFZ-KA0912NA SEZ-KD09 1215NA
MSZ-GE0609 121518NA MSZ-FE091218N MFZ-KA09 1218NA MXZ-3B24NA 164 4933 SEZ -KD09 12 15 18NA SLZ-KA09 12 15NA
MSZ-GE0609 121518NA MSZ-GA24NA MSZ-FE091218NA
MXZ-3B30NA 4933230MFZ-KA091218NA SEZ -KD09 121518NA SLZ-KA09 12 15NA
MSZ-GE0609121518NA MSZ-GE24NA MSZ-FE09 12 18NA
MXZ-4B36NA 230 4933MFZ-KA091218NA SEZ -KD09121518NA SLZ-KA09 12 15NA
MSZ-GE0609 12 15 18NA MSZ-GE24NA MSZ-FE09 12 18NA
MXZ-8B48NA 6698377MFZ-KA091218NA SEZ-KD09121518NA SLZ-KA09 12 15NA
PART NUMBER I USE WITH I DESCRIPTION
Port Adapters and Connection Pipes MAC-A454JP-E MXZ-Series Adapter 38 X12
MAC-A455JP-E MXZ-Series Adapter 12 X38
MAC-A456JP-E MXZ-Series Adapter 12 X58
MSDD-50AR-E MXZ-Series Branch Box Tee Distribution Pipe - Flare Connection between two branch boxes
MSDD-50BR-E MXZ-Series Branch Box Tee Distribution Pipe - Braze Connection between two branch boxes
PAC-493PI MXZ-Series Adapter 14 X38
PAC-SG76RJ-E MXZ-Series Adapter 38 X58
OPTIONAL ACCESSORIES CONTINUED ON NEXT PAGE
49 amp 66 applies to installations in which the outdoor unit is installed below indoor unit26 MITSUBISHI ELECTRIC
OPTIONAL ACCESSORIES (CONTINUED)
PART NUMBER USE WITH DESCRIPTION Control Options and Accessories
M21 JKO 307 M-Series Indoor Units Remote temperature sensor for M-Series indoor units
MAC-397IF-E
MAC-399IF-E
PAC-YU25HT
PAR-21 MM-G
M-Series INVERTER Units
M-Series INVERTER Units
SEZ-KD Indoor Units
Use with P-Series SEZ and for wired M-Series Controller
MA and contact terminal interface - Required to use PAR-21 MM wired wall mount controller with M-Series Systems
CMCN M-NET control adapter I Interface for Mr Slim M-Series MSYZ SEZ I MFZ
External Fan I Heater control relay adapter
Deluxe MA remote controller (Requires MAC-397IF-E for use with M-Series - MSYZ MFZ)
SEZ Wireless remote controller for SEZ units (Requires signal receiver PAR-SA9FA-E)PAR-FL32MA
PAR-SA9CA-E SEZ Wireless signal receiver for SEZ
3-pole disconnect switch 30A 600V turns off power between indoor and outdoor units shyM-SeriesTAZ-MS303
mounts in 2 X 4 utility box and requires standard single gang switch platecover - Low Ambient
ICM-326HM-2 M-Series Non-INVERTER units Low ambient head pressure controller MUZ-GE091215 IVIUZ-FE0912 SUZ-KD091215
Drain pan heaterMAC-640BH-U outdoor unit
MAC-641 BH-U MUZ-GE18 SUZ-KD18 outdoor unit Drain pan heater Filters
MAC-1415FT-E Anti-allergy enzyme filter
MAC-2300FT
MSZlMSY-D3036
Anti -allergy enzyme filter
MAC-308FT
MSYMSZ-GA24
MSZ-FD912 I FE0912 Platinum deodorizing filter
MAC-408FT-E Anti-allergy enzyme filter
MAC-415FT-E
M-Series Indoor Unit - GE09GE12GE15GE18
MFZ-KA Air Cleaning FilterAnti-Aliergy Enzyme Filter
MAC-418FT Anti-allergy enzyme filter
Filter Boxes
FBL1-1
MSZ- FD912 I FE091 2
FB Series Filter Box for SEZ-KD09NA Optional filter box with MERV 8 filters
FB Series Filter Box for SEZ-KD1215NAFBL1-2 Optional filter box with MERV 8 filters
and PEA-A 12M
FBL1-3 FB Series Filter Box for SEZ-KD18NA Optional filter box with MERV 8 filters
Pumps
SI1730-230 MSYZ - 30000 Btuh or greater Sauermann mini condensation pump 230V
S13100-115 MS-Series - non-INVERTER Sauermann mini condensation pump 115V
S13100-230 Sauermann mini condensation pump 230VMSYZ - Less than 30000 Btuh
Miscellaneous BRP-1 Bottom Return Plate for SEZ-KD09NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-2 Bottom Return Plate for SEZ-KD12KD15-NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-3 Bottom Return Plate for SEZ-KD18NA Converts low profile ducted indoor unit from rear return to bottom return
BV12FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderreglnsulated - 12
BV14FSI Use with any Mr Sl im multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 14
BV38FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 38
BV58FSI Use with any IVIr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 58
Condensing unit wall mounting brackets (set of 2) - 440 lb capacity painted steel NOTE CWMB1 IVIU and PU outdoor units Installer is responsible to select and provide suitable hardware and materials to insure proper
mount of bracket to wall
DSD-400N M-Series DiamondBacktrade Platform Stands MUZ-GE18 I MUZ(y)-03036 I
MAC-811DS Drain socket assemblySUZ-KA18
MAC-851DS MUZ-FD0912 Drain socket
MAC-855SG M-Series Air outlet guide
MAC-856SG M-Series Air outlet guide - MXZ-3B24 I 3B30 I 4B36 NA
MAC-860DS MUZ-GE091215 I MUZ-FE0912 Drain socket
MAC-889SG M-Series Air outlet guide- MXZ-2B20NA
MAC-S99SG M-Series Air outlet guide
PAC-SG59SG-E IVIXZ-SB4SNA Air outlet guide (1 piece) I MXZ-SB48NA (Requires 2 pieces)
PAC-SG61 DS-E MXZ-8B4SNA Drain socket - connector
PAC-SG64DP-E MXZ-SB48NA Drain pan
RCMKP1CB lVI-Series Wireless Lockdown bracket for remote controller
lILTRILlTE1 All M-Series Condensing unit mounting pad 16 x 36 x 3
MITSUBISHI ELECTRIC 27
MXZ-8 Series Port Adapter chart Port Adapter Unit Port
Combinations Required Size
MXZ-2B20NA-1
2-zone combinations wi NA
A 38 x both units s12K 14
1-MAC-A454JP-E B 38 x
6+15 14
9+15 1-MAC-A454JP-E
MXZ-3B24NA
All rated 2-zone combina-NA
A 12 x tions 14
All rated 3-zone combina-NA
B 38 x tions 14
C 38 x 14
MXZ-3B30NA
2-zone combinations wi at NA
A 12 x least one unit s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
9 + 24 14
3-zone combinations wi 1-MAC-A455JP-E
all units s12K
All other rated 3-zone NA
comb
MXZ-4B36NA
2-zone combinations wi at NA
A 12 x least one un it s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
6 + 24 14
1-MAC-A456JP-E D 38 x
9 + 24 14
3-zone combinations wi at NA
least two units s12K
3-zone combinations wi 1-MAC-A454JP-E
two units15K
6+6+24 or 6+9+24 1-MAC-A456JP-E
9+9+24 1-MAC-A456JP-E
4-zone combinations wi at 1-MAC-A455JP-E
least three units s12K
6+6+15+15 1-MAC-A454JP-E
6+6+15+15 1-MAC-A454JP-E
Note When using the Pu-A24BA PCA-A24KA or PEAD-A24AA two port adapter will be needed 1-MAC-A456JP-E (12 x 58) A port or 1-PACshySG76RJ-E (38 x 58) B C and D ports and 1-PAC493PI (14 x 38)
28 JMITSUBISHI ELECTRIC
6+6+246+9+24 6+12+249+9+24 9+12+24 or 12+12+24
6+15+24 6+18+24 9+15+249+18+24 12+15+24 or 12+18+24
15+15+24 15+18+24 or 18+18+24
15+24+24 or 18+24+24
Combinations of 4 or more zones
1-PAC-SG76RJ-E
See notes for application below
2
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
See notes for application below
PORT A =38 gas x 14 liquid
PORT B =38 gas x 14 liquid
PORT C =38 gas x 14 liquid
PORT A =38 gas x 14 liquid
PORT B = 38 gas x 14 liquid
PORT C = 38 gas x 14 liquid
PORT D =38 gas x 14 liquid
PORT E =12 gas x 14 liquid
Notes for application bull Check the lineset sizes for your indoor selected models bull Select the branch box or boxes needed for your application bull Compare indoor unit lineset sizes as compared to branch
box sizes bull Connect 15K + indoor units to the larger port on the
(PAC-AKA51 BC) bull Adapt lineset size with appropriate port adapter from
above list bull When using the PU-A24BA or PEAD-A24AA two port
adapter will be needed 1-MAC-A456JP-E (12 x 58) or 1-PAC-SG76RJ-E (38 x 58) and 1-PAC493PI (14 x 38)
-fv
~ DIAMONDBACKtrade
~) BV-Series Ball Valves Model numbers
BV14FFSI BV38FFSI
LISTED 891N REFRIGERANT
BV12FFSI VALVE bull Engineered for Mini-split andBV58FFSI
Multi-split HVAC Units bull Size available 14 38 12 58
bull Full Port Designbull Fully factory assembled bull Furnace brazed and pressure tested bull 700 PSIG Rated bull Each ball valve is equipped with Schraderreg Valve
for refrigerant service bull R-410A Compatible bull Design working pressure 700 PSIG bull Temperature range bull Flare Connections
-40 0 F to +3250 F (-400 C to + 1490
C) bull Forged brass body and seal cap bull Teflonreg seals and gaskets (no synthetic a-rings) bull Seal cap design permits valve operation without
removal of seal cap bull Suitable for use with R-11 R-22 R-123 R-125
R-134A R-236FA R-4202A R-402B R-404A R-407C R-410A R-500 R-502 and R-507
bull One year limited materials and workmanship
Part Number SAE Flare
A B C 0 E F
BV14FFSI 14 619 260 180 122 142 110
BV38FFSI 38 630 267 180 122 142 110
BV12FFSI 12 651 267 180 122 142 110
BV58FFSI 58 664 267 180 128 142 110
Ball valves come With an insulation piece warranty on Ball Valves
~ DIAMONDBACKtrade
~) Platform Stands
Lift the Mitsubishi Electric Comfort Solution
outdoor unit to new heights with our Diamondback Platform Stands
bull Easy to install
bull Available for all sizes of Mr Slim outdoor units
bull Color matched to the outdoor units
Model Number DSD-400N
L 15-34 x W 3-14 x H 3-14
r
)MITSUBISHI ELECTRIC 29
~ DIAMONDBACKtrade LINESETS
~~
Twin-Tube Lineset Insulation Design
bull Balanced outside diameter for uniform coiluncoil position stability
bull Minimum 12 insulation thickness on both tubes Diamondback Advantages include the following features
bull Quick efficient and economical field installation using factory applied Twin Tube insulation and flare connections with flare nuts mounted
bull Correct lengths for reducing waste and time
bull Quality consistency and economy
bull All Diamondback Lineset tubing is tested in accordance with ASTM E243
Filter Boxes
FB Series filter boxes are available in compatible sizes for all Mr Slim horizontal ducted indoor units
FBL 1 filter boxes include 1 thick pleated MERV 8 filter(s) installed Filters are tested in accordance with ANSIASHRAE Standard 522 and Rated Class 2 under UL Standard 900
The cabinet is constructed of non-insulated 20 gauge G-60 galvanized
FBL1-1 FB Series Filter Box for SEZ-KD09NA
FBL1-2 FB Series Filter Box for SEZ-KD12KD15-NA
FBL1-3 FB Series Filter Box for SEZ-KD18NA
steel with foam gasket and provides an air-tight connection to indoor unit and access door Gasket material complies with UL 723 requirements
A screw-through cabinet design for secure attachment to indoor unit and return connection in rear is easily field-converted to bottom return
30 MITSUBISHI ELECTRIC
bull
bull
bull
bull
bull
bull
LINE-HIDE~ Put a professional finish on air-conditioning
installations with an easy-to-install modular
system that beautifies exteriors and
protects Linesets drainlines and wiring
Can be use it indoors too Meets UL94v-O for interior applications
Has snap-on covers and a full selection of couplings elbows T-joints caps and more for any application complex or simple
Offers high-quality PVC with UV inhibitors for outdoor service in all weather conditions
Can be painted with most house paints to match exterior decors
Is not just for HVAC Hide any exterior cabling piping or wiring
Available in four sizes 2-14 3 4 and 6 tubes
Download a brochure at wwwline-hidecom to find out more information
For more information on our CITY MULTI VRF product line visit our website at wwwmitsubishiprocom
_lIJrUlllln ~ ~IIII1 fInll l
~
l bull bull
JMITSUBISHI ELECTRIC 31
- shy(MSY(Z)-D30NA MODEL SHOWN)
Vl J
09 (I)
I
N o J (I)
s Vl N Vl
-0 (I) n 31 n OJ 0 o J V)
Model Name Indoor Unit MSZ-GE18NA MSZ-FE18N MSZ-GE24NA MSZ-D30NA MSZ-D36NA
Outdoor Unit MUZ-GE18NA MUZ-FE18rK MUZ-GE24NA MUZ-D30NA MUZ-D36NA Rated Capacity Btuh 17200 18000 22500 30700 33200
Capacity Range Btuh 3700-18700 8200-25200 8200-31400 9800-30700 9800-33200
Total Input W 1640 (240-2070) 1270 (570-2280) 1800 (570- 3580) 3850 (620-3850) 4360 (620-4360) Cooling 1
Energy Efficiency SEER 192 202 190 145
Moisture Removal Pintsh 46 27 27 99 11 3
Sensible Heat Factor 071 084 075 064 062
Rated Capacity Btuh 21600 21600 27600 32600 35200
Capacity Range Btuh 3500-25200 7500-29700 7500-36900 8700-34000 8700-36000 Heating at 47deg F 2
Total Input W 1900 (230-2680) 1540 (520-2240) 2340 (520- 3650) 3360 (520-3600) 3840 (520-4100)
HSPF (Region IV) BtuhIW 10 103 10 82
Rated Capacity Btuh 13400 11700 16000 19500 21800
Heating at 17deg F 3 Total Input W 1450 2180 3290 2400 2820
Maximum Capacity Btuh 17200 19300 24600 20800 22800 Heating at 5deg F
Maximum Capacity Btuh 13562 21 600 21160 16305 19090
Power Supply Phase Cycle Voltage 1 Phase 60Hz 208230V 4
Indoor - Outdoor S1-S2 AC 208 230V Voltage Indoor - Outdoor S2-S3 DC12-24
Indoor - Remote Controller Wireless Type (Optional Wired Controller DC12V) MCA A 10 Fan Motor FLA 076
DRY (CFM) 230-275-339-420-533 388-469-628-738 388-469-628-738 389-639-848 Airilow (Cool) (Lo-Med-Hi-Super HI-Poweriul) 1
WET (CFM) 194-240-304-385-498 347-420-562-661 347-420-562-661 350-576-763
Airilow (Heat) (Lo-Med-Hi-Super HI-Poweriul) 2 DRY (CFM) 230-275-339-431-512 388-469-628-738 388-469-628-738 445-639-848
Sound Pressure Level (Cooling) (Lo-Med-Hi-Super 28-33-38-44-49 34-41-49-53 34-41-49-53 32-42-49
HI-Poweriul) 1
Sound Pressure Level (Heating) (Lo-Med-Hi-Super dB(A)
Indoor Unit 28-33-38-43-48 32-41-49-52 32-41-49-52 34-42-49-49HI-Poweriul) 2
External Finish Color Munsell No 1 OY 9202
W In 31-716 43-516 46-116
Dimension Unit D In 9-18 9-38 11-58
H In 11-5 8 12-1316 14-38
Weight Unit Lbs 22 37 40
Field Drainpipe Size OD In 58
MCA A 14 171 21
MOCP A 15 20 25
Fan Motor FLA 093
Model (Type) DC INVERTER-driven Twin Rotary
Compressor RLA 100 129 16
LRA 125 161 20
Airilow CFM 1730 1659 17691 701 1941
Outdoor Unit Refrigerant Control Linear Ex~ansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(A) 54 55 56
Sound Pressure Level at Heating 2 dB(A) 56 55 57
External Finish Color Munsell No 3Y 7811
W In 33-116
Dimensions D In 13
H In 33-716 34-58 33-716
Weight Lbs 119 141
Remote Controller Type Wireless Remote (Optional Wired Controller)
Type R410A
Refrigerant Charge Lbs Oz 3 7 43 410
Oil Type (FI Oz) NE022 (152) FV50S (135) NE022 (29)
Gas Side OD 12 58In
Refrigerant Pipe Liquid Side OD 14 38
Height Difference (Max) 50
Length (Max) Ft
100 I Connection
Mpthon IndoorOutdoor Flared Flared
NOTESTest conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg C) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F (24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F(6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 17deg F(-8deg C) WB 15deg F(-9deg C) 4 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice LIMITED WARRANTY ISeven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 13
(SEZ-KD12NA MODEL SHOWN)
SEZ HEAT PUMP TAX
CREDIT
Model Name Indoor Unit SEZ-KD09NA4 SEZ-KD12NA4 SEZ-KD15NA4 SEZ-KD18NA4
Outdoor Unit SUZ-KA09NA SUZ-KA12NA SUZ-KA15NA SUZ-KA18NA Rated Capacity Btuh 8100 11500 14100 17200
Capacity Range Btuh 3800-10900 3800-13300 3800-17000 3800-19000
Cooling 1 Total Input W 670 920 1170 1380
Energy Efficiency SEER 15 16 155 175 Moisture Removal Pintsh 15 24 26 34 Sensible Heat Factor 080 076 080 079
Rated Capacity Btuh 10900 13600 18000 21600
Heating at 4YO F 2 Capacity Range Btuh 4800-14100 4800-16400 4800-21100 4800-24900
Total Input W 1020 1140 1500 1700 HSPF(lV) BtuhIW 100 Rated Capacity Btuh 6700 9000 11900 13100
Heating at 1 yo F 3 Rated Total Input W 810 920 1200 1350 Maximum Capacity Btuh 7300 9800 13700 15000
Power Supply Phase Cycle Voltage 1 Phase 60Hz 208 230V 4 Indoor - Outdoor S1 - S2 AC 208-230V
Voltage Indoor - Outdoor S2 - S3 DC 12-24V Indoor - Remote Controller See optional accessories chart (pg 26 and 27) MCA A 1 Fan Motor FLA 051 057 074
Airflow (Lo-Med-Hi) DRY (CFM) 194-247-317 247-317-388 353-441-529 423-529-635
WET (CFM) 174-222-285 222-285-349 317 -396-4 76 381-476-572 External Static Pressure 3 In wG 002-006-014-020 Sound Pressure Level dB(A) 23-26-30 23-28-33 30-34-37 30-34-38
Indoor Unit External Finish Galvanized-Steel Sheets
W In 31-18 39 46-78
Dimension Unit D In 27-916
H In 7-78
Weight Unit Lbs 42 50 54 62 Field Drainpipe Size 00 In 1-14
MCA A 12 14
MOCP A 15 Fan Motor FLA 050 093
Model DC Inverter DC Inverter Twin Rotary
I (Type)Compressor
RLA 66 74 10
LRA 82 93 125
Airflow (CoolingHeating) CFM 11511225 12291172 1 2431 229 17301659
Outdoor Unit Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(A) 46 49 54 Sound Pressure Level at Heating 2 dB(A) 50 51 56
External Finish Color Munsell No 3Y 7811
W In 31-12 33-16
Dimensions D In 11-14 13
H In 21-58 33-716
Weight Lbs 66 77 80 119 Remote Controller Type See optional accessories chart (pg 26 and 27)
Type R410A
Refrigerant Charge Lbs Oz 116 2 9
Type (fl Oil
oz) NE022 (108)
Refrigerant Pipe Gas Side OD In 38 Liquid Side 00 In 14
Refrigerant Pipe Height Difference (Max) Ft 40 Length Length (Max) Ft 65
Connection IndoorOutdoor FlaredFlared
Method
316
NE022 (152)
12
50
100
I
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg C) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F(8deg C) WB 43deg F(6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 17deg F(-8deg C) WB 15deg F(-9deg C) 4 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
14 MITSUBISHI ELECTRIC
SEZ STATIC PERFORMANCE CURVES (SEZ-KD12NA4 MODEL SHOWN)
SEZ-KD09NA4 SEZ-KD09NA4 (External static pressure O06[inwG]) 208230V 60Hz
[020] V L
5 [016
~l [0 12
]
SEZ-KD09NA4
~ ltij
~ [008
Jj
]
]
[004J ~
V V Middle
Low
V
19h
Rated point
1
o [141] [176J 1212) )247] [282J [318]
Airll ow rat e [CFM)
SEZ-KD12NA4 (External static pressure O06[inwG]) 208230V 60Hz
[020
5 [016
]
]
[353J
Limit
]
~ V
~ [ [0 12
u ltijJ[008
[004
]
_V ]~ Low
V
k-iddle
Rated POint
o [212) [247] [2 82] [318] [353] [388]
Airtlow rate [C FM]
SEZ-KD1SNA4 (External static pressure O06[inwGl) 208230V 60Hz
[424)
1020]
5 [016
~ ~ [012
~ ltij
~ [008
Jj
J
)
]
[004 ]
o
VV V [ Low
VV
vV High
Middle
I Rated point
[282] [318) [353] [388] [424] [459] [494] [530] [565J
Airllow rat e [CFM]
SEZ-KD18NA4 (External static pressure O06[inwG]) 208230V 60Hz
50 10 20]
] 40
5 [016
s 30 [ (012 )
ltij 20 ~ [008 )~Jj
10 [004]
V
Low
v Limit
rIV High
V [ Middle
~
1
Rated point
f318) [353) [388] [424] [459] [494] [530] [565] [600] [636] [671 )
Airllow rate [CFM]
(External static pressure O14[inwG]) 208230V 60Hz 80
[0 32
70 [028
5 60 [024
20 [0 08
10 [004
]
]
J
]
]
J
]V
]
U~it
V
k
High
~V Rated POI~1 V Middle Low
~
o [141] [1 76] 12121 )247J [282] [318]
Airtlow rate [CFM)
SEZ-KD12NA4 (External stat ic pressure O14[inwG]) 208230V 60Hz
[032]
[028J
5
[353]
J
~ [024
-~ [020] V-is
J V Il Hi9h Rated point
[016
~ ]
V V1 Middle
~ [012
[008]~
[004)
o [212)
[247)
SEZ-KD1SNA4
Low r
[282] [31 8) [353]
Airllow rale [CFM]
[388]
(External static pressure O14(inwG]) 208230V 60Hz
[032J
[424
]
2 V[028
5 [024]
V-i
] V High i [020
] K
Middle Rated point [0 16
g ]
~ -
QJj [0 12
J Low
[008
] I
~
[004
o [282J [318) [353J [388J [424) [459] [4 94] [530) [565)
Airt low rate [CFM]
SEZ-KD18NA4 (External statiC pressure O14(inwG]) 208230V 60Hz
1032
1028
~ 1024
-~ [0 20
is (0 16 ltij E ~ [012
(008
(004
o
I
]
]
)
]
)vlt ]
]
~ V
VV
Low
Limit
V
Ji9h
Middle l
Rated point
1 t
1
~ [318] [353] [388] [424] [459) [4 94] [530) [565) [600] [636] [671)
Airllow rate [CFM]
(External static pressure O20(inwG]) 208230V 60Hz
[032 ]
[028 J
5 [024
~ [020
is [016
1 [012Jj
[008
[004
J
]
]
] )
]
V Low
umz V High
~V
Rated point
Middle
1
[141] [176] [212) [247) [282) [318) [353J
Airtlow rat e [CFM]
SEZ-KD12NA4 (External static pressure O20(inwG]) 208230V 60H z
[032 ] LLimit
)
[0 28
5 ]
V
[024 -~ [020] V Rated point
Highis ~
) V
bull Middle
]~V I
[016
~ ~ [012
] Low
[008
]
[0 04
o [212) [247] [282] [318] [353] [388] [424]
Airllow rate [CFM]
SEZ-KD1SNA4 (External static pressure O20(inwG]) 208230V 60Hz
80 [032 ]
70 [0 28
~ [ O~~ -
ltij
E 30 ~ [0 12
20 [008
10 [004
o
)
J
]
]
JV
J
J
Limit V
LV High
V ~
K Rated point
Middle
VV 1gt
Low
I-
~ [282) [318) (353] (388) (424) 1459] [494] 15301 [565)
Airtlow rate [CFM]
SEZ-KD18NA4 (External static pressure O20[inwG]) 208230V 60Hz
[032
[028
~ [024sect
I [020
~ [016
~ Jj [0 12
[008
[004
o
]
)
]
]
]
~ )
]
]
1V
V 1
V
Low
1 limit
~~~ I ~~ High
~ R~ted pOini
Middle
1 1 -
[31 8) [353] [388] [424) [459] [494] [530] (565) [600] (636) [671J
Airllow rate [CFM)
Vl ~ ca (I)
I
N o ~ (I)
Vl m N Vl
-0 (I) n 3-i n QJ ~ o ~ tn
Note ESP 20S230V 60 Hz See manual for Static Performance Curve including 002 in WG
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts ~MITSUBISH[ ELECTRIC 15
SLZ HEAT PUMP (SLZ-KA12NA MODEL SHOWN)
Model Name Indoor Unit SLZ-KA09NA SLZ-KA12NA SLZ-KA15NA
Outdoor Unit SUZ-KA09NA SUZ-KA12NA SUZ-KA15NA Rated Capacity Btuh 8400 11100 15000
Capacity Range Btuh 3100-10900 3100-13300 3100-22200
Cooling 1 Total Input W 700 920 1460
Energy Efficiency SEER 15 154 16 Moisture Removal Pintsh 12 23 45 Sensible Heat Factor 080 076 080
Rated Capacity Btuh 10900 13 600 18000
Heating at 4r F 2 Capacity Range Btuh 3100-14100 3100-17100 3100-17100 Total Input W 930 1180 1950 HSPF (IV) BtuhIW 96 Rated Capacity Btuh 6200 8300 10200
Heating at 17deg F 3 Rated Total Input W 740 930 1310 Maximum Capacity Btuh 8300 10200 12000
Power Supply Phase Cycle Voltage 1 Phase 60Hz 208 230V 4 Indoor - Outdoor S1 - S2 AC 208-230V
Voltage Indoor - Outdoor S2 - S3 DC 12-24V
Indoor - Remote Controller See optional accessories chart (pg 26 and 27) MCA A 1 Fan Motor FLA 023 028 028
Airflow (Lo-Med-Hi) DRY (CFM) 280-320-350 280-320-390 280-320-390
WET (CFM) 250-290-320 250-290-350 250-290-350
Sound Pressure Level dB(Al 29-32-38 30-34-39 31-35-40
Indoor Unit External Finish Galvanized-Steel Sheets Grille Munsell 64Y 8904
W In 22-7 16 (25-58)
Dimension Unit (Grille) D In 22-716 (25-58
H In 8-316 (1316)
Weight Unit (Grille) Lbs 36 (7) Field Drainpipe Size 0 0 In 1-14 MCA A 12 MOCP A 15 Fan Motor FLA 050
Model (Type) DC INVERTER-driven DC INVERTER-driven
Compressor RLA 66
LRA 82
Airflow (CoolingHeating) CFM 11511225 1 229 1 172
Outdoor Unit Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(AJ 46 49 Sound Pressure Level at Heating 2 dB(AJ 50 51
External Finish Color Munsell No 3Y 781 1
W In 31 shy12
Dimensions 0 In 11-14
H In 21-58
Weight Lbs 66 77
~e R410A
Refrigerant Charge Lbs Oz 1 16
Oil Type (fl oz) NE022 108)
Refrigerant Pipe Gas Side 0 0 In 38 Liquid Side 00 In 14
Height Difference (Max) Ft 40 Refrigerant Pipe Length
Length (Max) Ft 65
Connection Method IndoorOutdoor FlaredFlared
29
Twin Rotary 74
93
12431 229
80
NE022 l152) 12
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg C) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F(8deg C) WB 43deg F(6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 17deg F(-8deg C) WB 15deg F(-9deg C) 4 Indoor units receive power from outdoor units through field-supplied interconnectedwiring Specifications are subject to change without notice
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
16 MITSUBISHI ELECTRIC
MHK1 WIRELESS REMOTE CONTROLLER KIT Exclusive for INVERTER-driven Mr Slimreg Systems VlWireless Technology a J
JMITSUBISHI ELECTRIC
Wireless Receiver
MHK1 Kit includes
09 mMRCH1 WIRELESS REMOTE CONTROLLER I Nbull Backlit easy-to-read display o
bull Dual setpoint control with system changeover J m
bull Enabled with RedLlNKTM reliability
bull Compatible with MCCH1 Vl Portable Central Controller m
N bull Installs Anywhere Vl
MFH1 WIRELESS RECEIVER N Vlbull Required for MRCH1 Wireless
CRemote Controller m bull Enabled with RedLiNK reliability n
31 n OJ o J en
SEZ and SLZ 11 systems with SUZ outdoor unit
Function Description
ONOFF OnOff operation for a single indoor unit
Operation Mode Cool I Drying I Auto I Heat I Fan only Available operation modes dependant on connected system
Temperature Setting Set temperature from 50degF - 8rF depending on operation mode and connected system
System Changeover Deadband Value 2-8degF
Schedule Operation 5-25-1-1
Fan Speed Setting HiMid-2Mid-1 IlowlAuto Available fan speed settings dependant on connected system
Air Flow Direction Setting Air flow angles 100deg - 80deg - 60deg - 40deg and oscilate Available air flow direction settings dependant on connected system
PermitProhibit Function Individual prohibit operations for each remote controller function (ONI OFF Set Temperature and Operation Mode)
Space Temperature Displays the measured space temperature
Error Indication Displays error code
Display Outside Temperature and Humidity
Requires optional MOS1 Outside Air Sensor
Dimensions - ryv x D x H) Remote Controller 5-316 x 1-12 x 3-916 Receiver 3-14 x 1-516 x 6-716
Operating Ambient Temperature Remote Controller 32 - 120degF Receiver -40 - 165degF
Operating Ambient Humidity Remote Controller 5 - 90 RH (non-condensing) Receiver 5 - 90 RH (non-condensing)
Power Supply 2 AA batteries
MRCH1 MIFH1 MRC1
Wireless Wall-Mounted Remote Controllers Wireless Receiver Cable
Accessories MCCH1 MOS1
Portable Central Controllers Outside Air Sensor
MITSUBISHI ELECTRIC 17
MULTIPLE ROOMS WITH INDIVIDUAL CONTROL FROM A SINGLE SYSTEM Enjoy ideal levels of comfort in the rooms you use most with our multi-room system Each room (zone) operates independently People in different rooms - the kitchen master bedroom or living room - can enjoy temperature settings that make each of them most comfortable
If you re looking for a complete comfort solution for several different rooms the MXZ multi-room system is the right choice The system is flexible enough to conform to a particular cooling and heating need and offers numerous different indoor unit combinations In addition up to eight indoor units can be connected to one outdoor unit Now with a SEZ horizontal ducted unit and a MFZ floorshystanding unit homeowners can enjoy an even greater range of zoning options provided by an MXZ system
An MXZ multi-room system is an excellent choice for supplementing capacity to a current system conditioning newly furnished spaces or new additions and replacing a system within a home Homeowners can also benefit from lower energy costs year-round while staying comfortable thanks to Mitsubishi Electrics energy-efficient technologies that are a part of every system that we make
To add to the level of energy efficiency the MXZ -2B20NA and MXZ -3B24NA systems qualify for both ENERGY STARreg and the federal tax credit (See details on page 21 for applicable indoor unit combinations)
At right a single level home with several system types represented (For illustrative purposes only)
MFZ Floor-Standing Indoor Units for MXZ Heat Pump Systems
Floor-standing indoor unit mounts three inches above the floor and has front panel access to the filter for ease of cleaning
The MFZ units provide energy-efficient solutions to provide personalized comfort for difficult areas that may be smaller or dont have usable space on the walls
MFZ units on MXZ systems include the following features bull Top and bottom discharge vanes bull Hot-start technology bull Quiet operation bull Wireless remote control (optional wall-mounted controller)
18 MITSUBISHI ELECTRIC
MSZ Wall-Mounted Indoor Units for MXZ Heat Pump Systems
Providing a wide range of cooling and heating capacities each wall-mounted indoor unit mounts high on a wall and connects to a branch box or the outdoor unit by a refrigerant line run via a 3 hole The MSZ units provide highly efficient solutions to cooling and heating needs and provide personalized comfort for the individual zones in which they are installed
MSZ units on MXZ systems include the following features bull Sleek flat panel design bull Hot-start technology bull Quiet operation bull i-seeM sensor technology (MSZ-FE0912NA models only) bull Enhanced filtration system (MSZ-FE0912NA models only) bull Wireless remote control (optional wired wall-mounted controller)
SLZ Ceiling-Recessed Indoor Units for MXZ Heat Pump Systems
The new SLZ-KA ceiling casette systems offer a wide air-flow pattern for better air distribution
offered to your customers Installation can be done in a hard ceiling (with a access panel for servicing) or placed into a 2x2 drop ceiling With a built-in drain lift mechanism for condensate
removal and a 4 ventilation air intake knockout option the SLZ is ready to handle a variety of installation needs
SLZ units on MXZ systems include the following features bull Wide air-flow pattern for better air distibution bull 4 ventillation air intake knockout bull Built-in condensate lift mechanism bull Wireless RedLlNKTM remote controller
SEZ Horizontal Ducted Indoor Units for MXZ Heat Pump Systems
SEZ ducted units can provide split air-conditioning system advantages with the added benefit of being concealed to provide virtually no visual footprint within the conditioned space other than a register and grille for the air to flow With the use of short run ductwork these units can provide comfort to a single room that needs air dispersed evenly throughout the space unusually shaped rooms and adjacent rooms
The SEZ unit on MXZ systems include the fOllvowin fatures _
g~e~~~~==Zl[bull Concealed design for short-run ductwork bull Quiet operation bull Built-in condensate lift mechanism
JMITSUBISHI ELECTRIC 19
s c t
I
N o J ro o ltro ~ ro ~
DIAMOND COMFORT MXZ MULTI-ZONE SYSTEMS MXZ-B Series multi-zone systems provide personalized comfort control and energy efficiency in up to eight rooms with only a single outdoor unit The MXZ-B Series system features include
bull Individual zone control bull Mix and match flexibility of indoor unit styles and combinations bull A wide range of indoor unit capacities that match the room size and requirements bull Flexible design options to tackle the most challenging multi-room installations bull Efficient systems including three systems [mxz series] that meet energy starltID and
federal tax credit requirements bull Simple quick and cost-effective installation keeps install costs down on new construction
and disruption to a minimum on renovations and refits
Efficiency and performance ratings depend on the number style and capacity of the indoor units installed with each Multi-Zone System
MXZ -2 B20 NA - 1 (2 1 ) MXZ -3 B24 NA (2 13 1) Ou tdoo r Unit Outdoor Uni t
MSZ-GE09NA Indoor Units
SEZ-KD12NA Indoor Unit
MSZ- GE06NA
~~~~li
(At least two indoor units MSZ-GE06NAIndoor Unit must be installed) Indoor Unit
(Two indoor units must be installed )
MXZ -3 B30 NA (2 1 3 1) Outdoor Unit
SEZ-KD12NA Indoor Unit
~~~i
(At least two indoor units MSZ-GE06NA must be installed)
Indoor Unit ~
MFZ- KD12NA Indoor Unit
MXZ-8B48NA (2 1-8 1) Outdoor Unit
(At least two indoor units
must be installed)
(At least two indoor units must be installed)
MFZ-KD09NA Indoor Units
MSZ-GE09NA Indoor Units
SEZ-KD12NA Indoor Unit
MSZ INDOOR UNIT
MSZ-FE18NA
PEAD HORIZONTAL -DUCTED INDOOR UNIT
PEAD-A24AA
MSZ INDOOR UNIT SEZ HORIZONTAL-DUCTED MSZ-FE18NA
INDOOR UNIT MFZ FLOOR-STANDING SEZ-KD18NA INDOOR UNIT
MFZ-KA12NA
20 AMITSUBISHI ELECTRIC
MULTI-ROOM MXZ-8 INVERTER HEAT PUMP R
Model Name Outdoor Unit MXZ-2B20NA-1 5 MXZ-3B24NA 6 MXZ-3B30NA MXZ-4B36NA 7
Indoor Unit
Cooling 1 Non-ductedl Ducted
Rated Capacity Btuh 1800020000 2200023600 28400127400 3540034400
Capacity Range Btuh 7800-20000 12600-25500 12600-28400 12600-36400
Total Input W 2190 (630-219QL 2460 (1000-2950) 3330 l1 000-3330) 3 940 (1 000-4020)
Heating at 4JO F 2 Non-ductedl Ducted
Rated Capacity Btuh 2200022000 2500024600 2860027600 3600034400
Capacity Range Btuh 8500-25500 11400-30600 11 400-36000 11400-43000
Total Input W 2620 (520-2620) 1900 (740-2600) 2220 (740-2820) 3100 (740-3940)
Heating at 1JO F 3 Non-ductedl Ducted
Rated Capacity Btuh 1250012500 1400014000 1600015100 2220020300
Rated Total Input W 13501430 13801570 21202 140 24302340
Maximum Capacity Btu h 1450014500 1880017000 1880018000 2460025400
Maximum Total Inl2ut W 15001590 21202230 21202140 33403450
Power Supply Phase Cycle Voltage 1-phase 60Hz 2081 230V 8
Voltage Indoor shy Outdoor S1 - S2 AC 2081 230V
Indoor shy Outdoor S2 - S3 DC12-24V
Outdoor Unit 4
MCA A 15 19
MOCP A 20
Fan Motor FLA 096 093
Compressor
Model (Type)
DC INVERTER-driven Twin Rotary
RLA 101 11 144
LRA 15
Airflow (CoolingHeating) CFM 14851 640 20681605 13651605 20682068
Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1
dB(A) 49 54 49 54
Sound Pressure Level at Heating 2
dB(A) 51 49 57
External Finish Color Munsell No 30Y 781 1
Dimensions
W In 33-116 35-716
D In 13 12-58
H In 27-1516 35-7116
Weight Lbs 130 150 153
Indoor Unit No of Units 2 23 23 234
Remote Controller Type Associated with the Indoor Unit
Refrigerant
Type R410A
Charge Lbs Oz 515 7 11 813
Oil Type (fl oz)
NE022 (237) NE022 (294)
Refrigerant Pipe Gas Side 00 In AB 38 A 12 BC 38 A 12 BCD 38
Liquid Side 00 In 14
Refrigerant Pipe Length Height Difference (Max) Ft 4933 9
Length (Max) Ft 164 (A+B) 230 (A+B+C) 230 (A+B+C+D)
Connection Method IndoorOutdoor FlaredlFlared
Compatible with the MSZ-A MSZ-GA MSZ-FD MSZ-FE MSZ-GE MFZ-KA and SEZ-KD series indoor units (PLA-18 amp PCA-24 on the MXZ-MXZ-3B PLA-24 amp PCA-24 on the MXZ-4B)
NOTES Test conditions are based on AHRI 210240 One indoor unit is turned off during low-speed testing under the new test conditions Systems actually exhibit higher energy efficiencies during normal operation
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F (35deg C) WB 75deg F (24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F (6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 600 F (160 C) Outdoor DB 17deg F (_80 C) WB 150 F (_90 C) 4 Refer to pages 12 and 13 for Indoor Unit specifications 5 Data from combination of two Indoor Units 9000 Btuh (non-ducted) or one 9000 Btuh and one 12000 Btuh (ducted) 6 Data from combination of two Indoor Units 6000 Btuh and one 9000 Btuh (non-ducted) or three 9000 Btuh (ducted) 7 Data from combination of four Indoor Units 9000 Btuh (non-ducted and ducted) 8 Indoor units receive power from outdoor units through field-supplied interconnected wiring 9 49 Applies to installations where the outdoor unit is installed below the indoor unit
Power factor equals 97 percent
Specifications are subject to change without notice
MULTI-ZONE ENERGY STAR AND TAX CREDIT SYSTEMS
Model Indoor Unit Combinations SEER HSPF
MXZ-2B20NA-1 2 x MSZ- GE09NA 18 8 9
MXZ- 3B24NA 2 x MSZ- GE06NA 1 x MSZshy GE09NA
17 5 9 3
MXZ- 3B24NA 2 x MSZ-GE06NA 1 x MSZ- GE12NA
17 5 93
For more details on all ENERGY STAR and tax credit systems go to wwwmitsubishicomfortcomtaxcredit
See page 25 for additional info on efficiency
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 21
MXZ-8B48NA THE ULTIMATE ZONING SOLUTION
The Mitsubishi Electric MXZ-S84SNA eight-zone unit As a member of the expanding MXZ-B Series of multi-zone systems the MXZ-8B outdoor unit incorporates branch boxes to connect up to eight indoor units MXZ- 8 B48 NA (2 1 - 8 1 )
Outd oor Uni t The INVERTER-driven compressor at the heart of the MXZ-8B -~-- shy
outdoor unit provides variable capacity control allowing the system to adjust to the specific demands of the interior space ~ as needed not the hard start and stop of a traditional system I[iDA Jinstalled in most US homes
The MXZ -8B48NA has only one port on the outdoor unit for two insulated refrigerant lines which run into the home or business to connect to a branch box or boxes From the branch box(es) gas and liquid refrigerant piping run to each of the indoor units The LEV in the branch box(es) controls the refrigerant flow as the load of each zone changes
Through the branch box(es) (the PAC-AKA31 BC three-port andor the PAC-AKA51 BC five-port) the system can connect from two indoor units up to eight indoor units depending on application requirements
The flexibility of the system doesnt stop there The MXZ-8B48NA has rated capacities of 48000 Btuh for cooling and 54000 Btuh for heating System operation however can range from a minimum 12000 Btuh to a maximum 54000 Btuh in cooling and a maximum of 60000 Btuh in heating This type of performance supports a large variety of applications
The MXZ-8B48NA allows for further flexibility because it supports a connected indoor unit capacity from 22 to 130 or 12000 Btuh to a maximum 70200 Btuh depending on diversity
Connectable Indoor Units General Features bull Four-ton outdoor unit can support up to
eight indoor units using branch boxes bull Wide variety of indoor unit styles
-=--_-=-----= - - J _ 1
including wall-mounted floor-standing MSZ-FE09 12 18NA MSZ-GE06 09 12 15 18 24NA ceiling-cassette ducted
bull Individual control up to eight (8) zones using wired or wireless controls
bull Advanced microprocessor control bull Auto restart following a power outage bull Self-check function offering SEZ-KD09 1215 18NA PEAD-A24AA
integrated diagnostics ~--- Jbull Limited warranty five years on parts and
defects and seven years on compressors
SLZ-KA09 1215NA MFZ-KA09 12 18NA
22 MITSUBISHI ELECTRIC LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
I
RMULTI-ROOM MXZ-8 INVERTER HEAT PUMP
Model Name Outdoor Unit MXZ-BB4BNA Cooling 1 Rated Capacity
Non-ducted Rated Total Input Ducted
Maximum Capacity
Rated CapacityHeating at
Rated Total InputIndoor Unit 4JO F 2 Non-
ductedDucted Maximum Capacity
Rated Capacity Heating at
Rated Total InputlJO F 3 Non-ductedDucted Maximum Capacity
Power Supply Phase Cycle Voltage
Indoor - Outdoor Sl - S2 Voltage
Indoor - Outdoor S2 - S3
MCA
Recommended FuseBreaker Size
Fan Motor
Compressor
Airflow (CoolingHeating)
Refrigerant Control
Outdoor Unit Sound Pressure Level at Cooling 1
Sound Pressure Level at Heating 2
External Finish Color
Dimensions
Weight
Total Capacity 22-130
Indoor Unit ModelQuantity
Remote Controller Type
Type
Refrigerant Charge
Oil
Gas Side OD Refrigerant Pipe
Liquid Side OD
Height Difference (Max)
Maximum Distance between (Outdoor unit and farthest indoor unit)
Refrigerant Pipe Length Maximum Pipe Length -Branch box to Indoor Unit
Total Maximum line length between Branch Box and All Connected Indoor Units
Total Length (Max)
Connection Method IndoorOutdoor
Includes both branch boxes if there are two
Branch Boxes (At least one branch box required)
Btuh
W
Btuh
Btuh
W
Btuh
Btuh
W
Btuh
A
A
Type x Quantity
Motor Output (kW)
Model (Type)
Motor Output (kW)
CFM
dB(A)
dB(A)
W In
D In
H In
Lbs
Btuh
Lbs Oz
Type (fl oz)
In
In
Ft
Ft
Ft
Ft
Ft
4800048000
57806470
54000
5400054000
48205270
60000
3300034700
29503390
3660036550
1 Phase 60Hz 208 230V
AC 208-230V
DC12-24V
32
40
Propeller x 2
0086 + 0086
DC INVERTER-driven Scroll
29
3530
Linear Expansion Valve
54
55
Munsell No 3Y 78 11
37-716
13+1-3 16
53-3 16
278
12000 - 70200
600 - 24000 2-8
Associated with Indoor Unit Model
R410A
18 112
FV50S (73)
58
38
6698 4
230
49
197
377
FlaredFlared
Compatible with the MSZ-A MSZ-FO MSZ-FE MSZ-GE MFZ-KA SEZ-KD PLA and PEAD series indoor units
NOTES Test conditions are based on AHRI 210240 One indoor unit is turned off during low-speed testing under the new test conditions Systems actually exhibit higher energy efficiencies during normal operation
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F (35deg C) WB 75deg F (24deg C)
2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 4]0 F (8deg C) WB 43deg F (6deg C)
3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 17deg F (-8deg C) WB 15deg F(-9deg C)
4 66 applies to installations when the outdoor unit is installed below the indoor unit
Power factor equals 97 percent
Specifications are subject to change without notice
Note Maximum installed capacity is the maximum total of all connected indoor units NOT the maximum capacity produced
Only a single Lineset is needed from the outdoor unit to branch box
See page 25 for MXZ-B information on efficiency
Required Branch Boxes for MXZ-SB4BNA (Maximum of 2 branch boxes can be connected to one outdoor unit requires joint MSDD-50AR-E or MSDD-50BR-E)
s c d N o J ro Vl
0 ro n 3i n OJ d o J U)
PAC-AKA51 BC Branch Box
PAC-AKA31 BC Branch Box LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 23
MSZ WALL-MOUNTED INDOOR UNITS (FOR MXZ-8 OUTDOOR UNITS)
R
(MSZ-GE12NA MODEL SHOWN)
-000 IIIIIII 9000 9000 12000 12000 14000 17200
Heating at 4r Rated Capacity Btuh 7200 10900 10900 14400 13600 18000 21600
F2 Power Supply I Phase Cycle Voltage J -phase 60Hz 208 230V 3
Iindoor Outdoor S1 S2 AC 208 230V
Iindoor Outdoor S2 S3 DC12-24V Voltage
Iindoor Remote vomr Iller Wireless Type (Optional Wired vomroller DC 12V)
IMCA A 10 IFan Motor FLA 076
DRY 162-226shy145-170shy
162-226shy205-272shy 230-275shy
Airflow at Cooling (CFM)
145-170-237-321-399 339-381
237 -321shy381-410
335-420shy 339-420shy(Quiet-Lo-Med-Hishy 399 533 533 Super Hi or Lo-Med-
WET 144-202shy109-134shy
144-202shy170-237shy 194-240shy
Fan Hi-Powerful)1 (CFM)
109-134-201-286-364 307-343
201-286shy350-367
300-385shy 304-385shy364 498 498
Airflow at Heating 145-170shy 145-170shy 145-170shy 205-247shy 230-275shy
(Quiet-Lo-Med-Hi- WET 233-321shy 237-321shy
166-240shy237-321shy
166-240shy304-367shy 339-431shy
Super Hi or Lo-Medshy (CFM) 406 406
367 -381 406
399-420 463 512
Hi-Powerful) 2 Sound Pressure Level at Cooling
19-22-30shy 26-32-38shy 28-33-38shy(Quiet-Lo-Med-Hi-Super Hi or Loshy dB(A) 19-22-30-37 -43 22-31-39-42
37-45 22-33-43-45
44-49 44-49Med-Hi-Powerful) 1
Sound Pressure Level at Heating 19-22-30shy 26-30-35shy 28-33-38shy
(Quiet-Lo-Med-Hi-Super Hi or Loshy dB(A) 19-22-30-37 -43 22-31-40-42 37-43
22-23-43-44 40-46 43-48
Med-Hi-Powerful) 2
I External Finish Color Munsell No 10Y 92 02
IWln 31 middot716
Dimension Unit 10 In 9 18 10-18 9middot18 10-18 9-18
IH In 11-58
I Weight Unit ILbs 22 27 22 27 22 I Field Drainpipe ~D lin 58 Remote Con-
Type Wireless Remote (Optional Wired Controller) troller
ITvpe B41QA Refrigerant ~s$ideOD lin 38 Pipe I Liquid Side 00 In 14
Connection IndoorOutdoor FlaredFlared
Method
1~
II 18000 22500
21600 27600
388-469shy 38$-469shy628-738 628-738
347-420shy 347-420shy562-661 562-661
388-469shy 388-469shy628-738 628-738
34-41-49-53 34-41-49-53
32-41-49-52 32-41-49-52
43-516
9-38
12-1316 37
58 38
MXZ-2B20NA is also compatible with the MSZ-A and MSZ-FD series indoor units NOTES Test conditions are based on AHRI 210240
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F(6deg C) 3 Indoor units receive power from outdoor units through field-supplied wiring
Specifications are subject to change without notice LIMITED WARRANTY Seven-year warranty on compressor Five-year warranty on parts For data on specific indoor unit combinations see page 21
SEZ DUCTED INDOOR UNIT (FOR MXZ-8 OUTDOOR UNITS)
I
Notes 1 Cooling-Indoor DS 80deg F(267deg C) WS 67deg F(194deg C) Outdoor DS 95deg F (35deg C) WS 75deg F(239deg C)
2 Heating-Indoor DS 70deg F(211 deg C) WS 60deg F(156deg C) Outdoor DS 47deg F (83deg C) WS 43deg F(61 deg C)
3 External static pressure is factory set to 006 WGAdjustable via the
1---------t---+-----L-------------1~---__I PAR-21MAA
1--_____----__________+-____---L____----~_____________1 4 Indoor units receive power
jE~~~~-------------r----1-----~-~~~~~~~~-----___1 from outdoor units through fieldsupplied interconnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven-year warranty on compressor Five-year
1---------------------+---+------------------------1 warranty on parts
~--__I_~----------+-------~l----------I For data on specific indoor unit combinations see page 21 - 23
I--~------+~-----------~----------r_------------I
- Reference page 17 for SEZ static performance curves
24 MITSUBISHI ELECTRIC
25-30-35-40 26-31-36-41 35-38-42-46
25-30-35-40 28-31-36-41 35-38-42-47
MFZ FLOORLOW WALL INDOOR UNIT (FOR middotMXZ-8 OUTDOOR UNITS)
------shy
-==
Airflow at Heating (CFM) 177-198-219-332 184-201-219-335 261-275-297-434
Voltage
Fan
Airflow at Cooling (Lo-Med-Hi-Super Hi)1
169-205-251-314 251-279-325-394
163-197-241-303 170-207-252-309 241-269-313-379
(Lo-Med-Hi-Super Hi) 2
SLZ CEILING-RECESSED INDOOR UNIT (FOR MXZ-8 OUTDOOR UNITS) EFFICIENCY RATINGS
Voltage
Fan
Galvanized-steel SheetsMunsell 64Y 89 04
Refrigerant Pipe
Model Indoor Unit Type SEER HSPF
MXZ-2B20NA-1
Non-dueted 18 89
Dueted and Non-dueted 1675 87
Dueted 155 85
MXZ-2B20NA-1 ENERGY STAR amp
TAX CREDIT 2 x MSZ-GE09NA 18 89
MXZ-3B24NA
lJon-dueted 175 93
Dueted and Non-dueted 1625 89
Dueted 150 85
MXZ-3B24NA ENERGY STAR amp
TAX CREDIT
2 x MSZ-GE06NA 1 x MSZ-GE09NA
175 93
MXZ-3B24NA ENERGY STAR amp
TAX CREDIT
2 x MSZ-GE06NA 1 x MSZ-GE12NA
175 93
MXZ-3B30NA
Non-dueted 175 105
Dueted and Non-dueted 16 100
Dueted 145 95
MXZ-4B36NA
Non-dueted 18 93
Dueted and Non-dueted 16 5 92
Dueted 150 9 0
MXZ-BB4BNA
Non-dueted 15 87
Dueted and Non-dueted 14B B8
Dueted 147 89
Connection IndoorOutdoor FlaredFlared
Method
Notes 1 Cooling-Indoor DB 80deg F(267deg C) WB 67deg F(194deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(239deg C) 2 Heating-Indoor DB 70deg F(21 1 deg C) WB 60deg F(156deg C) Outdoor DB 47deg F(83deg C) WB 43deg F(61 deg C) 3 Indoor units receive power from outdoor units through field supplied interconnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 25
Notes 1 Cooling-Indoor DB 80deg F(267deg C) WB 67deg F (194deg C) Outdoor DB 95deg F (35deg C)WB 75deg F (239deg C)
2 Heating-Indoor DB 70deg F(211deg C) WB 60deg F (156deg C) Outdoor DB 47 F (83deg C) WB 43deg F (61 deg C)
3 Indoor units receive power from outdoor units through field supplied interco(lnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven -year warranty on compressor Five-year warranty on parts
Presently there is no 1 1 system with the MFZ indoor unit
s c
N o J ro Vl
C ro n ~ n OJ t o J V)
M-SERIES RATING CONDITIONS
INDOOR INTAKE AIR TEMPERATURE
OUTDOOR INTAKE AIR TEMPERATURE
COOLING
MAXIMUM
95degF DB 71 degF WB (MU SUZ MXZ-2B20-13B243B304B36) 90degF DB 73degF WB (MUZY-GE MUZ-FE MUzy-D)
115degF DB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B24 3B304B368B48)
MINIMUM 67degF DB 57degF WB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B201 3B243B304B36)
14degF DB (MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B24 3B304B36) 23degF DB (MXZ-8B48) 6rF DB (MU)
MAXIMUM 80degF DB 6rF WB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B243B304B36)
75degF DB 65degF WB (MUZY-GE MUZY-GA24 MUZ-FE SUZ MXZ-2B20-1 3B243B304B36) 70degF DB (MXZ-8B48)
HEATING
MINIMUM 70degF DB 60degFWB (MUZ-GE MUZ-GA24 MUZ-D MUZ-FE SUZ MXZ-2B20-1 3B243B304B36)
-13degF DB -15degFWB (MUZ-FE) -4degF DB -5degF WB (SUZ MUZ-GE) 5degF DB 4degF WB (MUZ-GA24 MXZ-8B48NA) 6degF DB 5degF WB (MXZ-2B20-1 3B24 3B304B36) 14degF DB 13degFWB (MUZ-D)
MU units operate at intake air temperature down to 10deg Fwith the addition of an ICM-326HM-1 low temperature control
REFRIGERANT TUBING SETS
OPTIONAL ACCESSORIES
REFRIGERANT LINE LENGTH FLARE FLARE _INDOOR UNIT OUTDOOR UNIT
MS-A09WA MU-A09WA 35 MS-A12WA
65 MU-A12WA 35
MSY-GE09NA 65
MUY-GE09NA 40
MSY-GE12NA
65
MUY-GE12NA 65 40
MSY-GE15NA MUY-GE15NA 40
MSY-GE18NA
65
MUY-GE18NA 100 50
MSZ-GE09NA MUZ-GE09NA 65 40
MSZ-GE12NA MUZ-GE12NA 40
MSZ-GE15NA
65
MUZ-GE15NA 40
MSZ-GE18NA
65
MUZ-GE18NA 100 50
MSY-GE24NA MUY-GE24NA 100 50
MSZ-GE24NA MUZ-GE24NA 100 50
MSY-D30NA MUY-D30NA 100 50
MSZ-D30NA MUZ-D30NA 50
MSY-D36NA
100
MUY-D36NA 50
MSZ-D36NA
100
MUZ-D36NA 100 50
MSZ-FE09NA MUZ-FE09NA 40
MSZ-FE12NA
65
MUZ-FE12NA 40
MSZ-GE06091215NA MSZ-FE0912NA
65
MXZ-2B20NA-1 164 4933MFZ-KA0912NA SEZ-KD09 1215NA
MSZ-GE0609 121518NA MSZ-FE091218N MFZ-KA09 1218NA MXZ-3B24NA 164 4933 SEZ -KD09 12 15 18NA SLZ-KA09 12 15NA
MSZ-GE0609 121518NA MSZ-GA24NA MSZ-FE091218NA
MXZ-3B30NA 4933230MFZ-KA091218NA SEZ -KD09 121518NA SLZ-KA09 12 15NA
MSZ-GE0609121518NA MSZ-GE24NA MSZ-FE09 12 18NA
MXZ-4B36NA 230 4933MFZ-KA091218NA SEZ -KD09121518NA SLZ-KA09 12 15NA
MSZ-GE0609 12 15 18NA MSZ-GE24NA MSZ-FE09 12 18NA
MXZ-8B48NA 6698377MFZ-KA091218NA SEZ-KD09121518NA SLZ-KA09 12 15NA
PART NUMBER I USE WITH I DESCRIPTION
Port Adapters and Connection Pipes MAC-A454JP-E MXZ-Series Adapter 38 X12
MAC-A455JP-E MXZ-Series Adapter 12 X38
MAC-A456JP-E MXZ-Series Adapter 12 X58
MSDD-50AR-E MXZ-Series Branch Box Tee Distribution Pipe - Flare Connection between two branch boxes
MSDD-50BR-E MXZ-Series Branch Box Tee Distribution Pipe - Braze Connection between two branch boxes
PAC-493PI MXZ-Series Adapter 14 X38
PAC-SG76RJ-E MXZ-Series Adapter 38 X58
OPTIONAL ACCESSORIES CONTINUED ON NEXT PAGE
49 amp 66 applies to installations in which the outdoor unit is installed below indoor unit26 MITSUBISHI ELECTRIC
OPTIONAL ACCESSORIES (CONTINUED)
PART NUMBER USE WITH DESCRIPTION Control Options and Accessories
M21 JKO 307 M-Series Indoor Units Remote temperature sensor for M-Series indoor units
MAC-397IF-E
MAC-399IF-E
PAC-YU25HT
PAR-21 MM-G
M-Series INVERTER Units
M-Series INVERTER Units
SEZ-KD Indoor Units
Use with P-Series SEZ and for wired M-Series Controller
MA and contact terminal interface - Required to use PAR-21 MM wired wall mount controller with M-Series Systems
CMCN M-NET control adapter I Interface for Mr Slim M-Series MSYZ SEZ I MFZ
External Fan I Heater control relay adapter
Deluxe MA remote controller (Requires MAC-397IF-E for use with M-Series - MSYZ MFZ)
SEZ Wireless remote controller for SEZ units (Requires signal receiver PAR-SA9FA-E)PAR-FL32MA
PAR-SA9CA-E SEZ Wireless signal receiver for SEZ
3-pole disconnect switch 30A 600V turns off power between indoor and outdoor units shyM-SeriesTAZ-MS303
mounts in 2 X 4 utility box and requires standard single gang switch platecover - Low Ambient
ICM-326HM-2 M-Series Non-INVERTER units Low ambient head pressure controller MUZ-GE091215 IVIUZ-FE0912 SUZ-KD091215
Drain pan heaterMAC-640BH-U outdoor unit
MAC-641 BH-U MUZ-GE18 SUZ-KD18 outdoor unit Drain pan heater Filters
MAC-1415FT-E Anti-allergy enzyme filter
MAC-2300FT
MSZlMSY-D3036
Anti -allergy enzyme filter
MAC-308FT
MSYMSZ-GA24
MSZ-FD912 I FE0912 Platinum deodorizing filter
MAC-408FT-E Anti-allergy enzyme filter
MAC-415FT-E
M-Series Indoor Unit - GE09GE12GE15GE18
MFZ-KA Air Cleaning FilterAnti-Aliergy Enzyme Filter
MAC-418FT Anti-allergy enzyme filter
Filter Boxes
FBL1-1
MSZ- FD912 I FE091 2
FB Series Filter Box for SEZ-KD09NA Optional filter box with MERV 8 filters
FB Series Filter Box for SEZ-KD1215NAFBL1-2 Optional filter box with MERV 8 filters
and PEA-A 12M
FBL1-3 FB Series Filter Box for SEZ-KD18NA Optional filter box with MERV 8 filters
Pumps
SI1730-230 MSYZ - 30000 Btuh or greater Sauermann mini condensation pump 230V
S13100-115 MS-Series - non-INVERTER Sauermann mini condensation pump 115V
S13100-230 Sauermann mini condensation pump 230VMSYZ - Less than 30000 Btuh
Miscellaneous BRP-1 Bottom Return Plate for SEZ-KD09NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-2 Bottom Return Plate for SEZ-KD12KD15-NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-3 Bottom Return Plate for SEZ-KD18NA Converts low profile ducted indoor unit from rear return to bottom return
BV12FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderreglnsulated - 12
BV14FSI Use with any Mr Sl im multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 14
BV38FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 38
BV58FSI Use with any IVIr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 58
Condensing unit wall mounting brackets (set of 2) - 440 lb capacity painted steel NOTE CWMB1 IVIU and PU outdoor units Installer is responsible to select and provide suitable hardware and materials to insure proper
mount of bracket to wall
DSD-400N M-Series DiamondBacktrade Platform Stands MUZ-GE18 I MUZ(y)-03036 I
MAC-811DS Drain socket assemblySUZ-KA18
MAC-851DS MUZ-FD0912 Drain socket
MAC-855SG M-Series Air outlet guide
MAC-856SG M-Series Air outlet guide - MXZ-3B24 I 3B30 I 4B36 NA
MAC-860DS MUZ-GE091215 I MUZ-FE0912 Drain socket
MAC-889SG M-Series Air outlet guide- MXZ-2B20NA
MAC-S99SG M-Series Air outlet guide
PAC-SG59SG-E IVIXZ-SB4SNA Air outlet guide (1 piece) I MXZ-SB48NA (Requires 2 pieces)
PAC-SG61 DS-E MXZ-8B4SNA Drain socket - connector
PAC-SG64DP-E MXZ-SB48NA Drain pan
RCMKP1CB lVI-Series Wireless Lockdown bracket for remote controller
lILTRILlTE1 All M-Series Condensing unit mounting pad 16 x 36 x 3
MITSUBISHI ELECTRIC 27
MXZ-8 Series Port Adapter chart Port Adapter Unit Port
Combinations Required Size
MXZ-2B20NA-1
2-zone combinations wi NA
A 38 x both units s12K 14
1-MAC-A454JP-E B 38 x
6+15 14
9+15 1-MAC-A454JP-E
MXZ-3B24NA
All rated 2-zone combina-NA
A 12 x tions 14
All rated 3-zone combina-NA
B 38 x tions 14
C 38 x 14
MXZ-3B30NA
2-zone combinations wi at NA
A 12 x least one unit s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
9 + 24 14
3-zone combinations wi 1-MAC-A455JP-E
all units s12K
All other rated 3-zone NA
comb
MXZ-4B36NA
2-zone combinations wi at NA
A 12 x least one un it s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
6 + 24 14
1-MAC-A456JP-E D 38 x
9 + 24 14
3-zone combinations wi at NA
least two units s12K
3-zone combinations wi 1-MAC-A454JP-E
two units15K
6+6+24 or 6+9+24 1-MAC-A456JP-E
9+9+24 1-MAC-A456JP-E
4-zone combinations wi at 1-MAC-A455JP-E
least three units s12K
6+6+15+15 1-MAC-A454JP-E
6+6+15+15 1-MAC-A454JP-E
Note When using the Pu-A24BA PCA-A24KA or PEAD-A24AA two port adapter will be needed 1-MAC-A456JP-E (12 x 58) A port or 1-PACshySG76RJ-E (38 x 58) B C and D ports and 1-PAC493PI (14 x 38)
28 JMITSUBISHI ELECTRIC
6+6+246+9+24 6+12+249+9+24 9+12+24 or 12+12+24
6+15+24 6+18+24 9+15+249+18+24 12+15+24 or 12+18+24
15+15+24 15+18+24 or 18+18+24
15+24+24 or 18+24+24
Combinations of 4 or more zones
1-PAC-SG76RJ-E
See notes for application below
2
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
See notes for application below
PORT A =38 gas x 14 liquid
PORT B =38 gas x 14 liquid
PORT C =38 gas x 14 liquid
PORT A =38 gas x 14 liquid
PORT B = 38 gas x 14 liquid
PORT C = 38 gas x 14 liquid
PORT D =38 gas x 14 liquid
PORT E =12 gas x 14 liquid
Notes for application bull Check the lineset sizes for your indoor selected models bull Select the branch box or boxes needed for your application bull Compare indoor unit lineset sizes as compared to branch
box sizes bull Connect 15K + indoor units to the larger port on the
(PAC-AKA51 BC) bull Adapt lineset size with appropriate port adapter from
above list bull When using the PU-A24BA or PEAD-A24AA two port
adapter will be needed 1-MAC-A456JP-E (12 x 58) or 1-PAC-SG76RJ-E (38 x 58) and 1-PAC493PI (14 x 38)
-fv
~ DIAMONDBACKtrade
~) BV-Series Ball Valves Model numbers
BV14FFSI BV38FFSI
LISTED 891N REFRIGERANT
BV12FFSI VALVE bull Engineered for Mini-split andBV58FFSI
Multi-split HVAC Units bull Size available 14 38 12 58
bull Full Port Designbull Fully factory assembled bull Furnace brazed and pressure tested bull 700 PSIG Rated bull Each ball valve is equipped with Schraderreg Valve
for refrigerant service bull R-410A Compatible bull Design working pressure 700 PSIG bull Temperature range bull Flare Connections
-40 0 F to +3250 F (-400 C to + 1490
C) bull Forged brass body and seal cap bull Teflonreg seals and gaskets (no synthetic a-rings) bull Seal cap design permits valve operation without
removal of seal cap bull Suitable for use with R-11 R-22 R-123 R-125
R-134A R-236FA R-4202A R-402B R-404A R-407C R-410A R-500 R-502 and R-507
bull One year limited materials and workmanship
Part Number SAE Flare
A B C 0 E F
BV14FFSI 14 619 260 180 122 142 110
BV38FFSI 38 630 267 180 122 142 110
BV12FFSI 12 651 267 180 122 142 110
BV58FFSI 58 664 267 180 128 142 110
Ball valves come With an insulation piece warranty on Ball Valves
~ DIAMONDBACKtrade
~) Platform Stands
Lift the Mitsubishi Electric Comfort Solution
outdoor unit to new heights with our Diamondback Platform Stands
bull Easy to install
bull Available for all sizes of Mr Slim outdoor units
bull Color matched to the outdoor units
Model Number DSD-400N
L 15-34 x W 3-14 x H 3-14
r
)MITSUBISHI ELECTRIC 29
~ DIAMONDBACKtrade LINESETS
~~
Twin-Tube Lineset Insulation Design
bull Balanced outside diameter for uniform coiluncoil position stability
bull Minimum 12 insulation thickness on both tubes Diamondback Advantages include the following features
bull Quick efficient and economical field installation using factory applied Twin Tube insulation and flare connections with flare nuts mounted
bull Correct lengths for reducing waste and time
bull Quality consistency and economy
bull All Diamondback Lineset tubing is tested in accordance with ASTM E243
Filter Boxes
FB Series filter boxes are available in compatible sizes for all Mr Slim horizontal ducted indoor units
FBL 1 filter boxes include 1 thick pleated MERV 8 filter(s) installed Filters are tested in accordance with ANSIASHRAE Standard 522 and Rated Class 2 under UL Standard 900
The cabinet is constructed of non-insulated 20 gauge G-60 galvanized
FBL1-1 FB Series Filter Box for SEZ-KD09NA
FBL1-2 FB Series Filter Box for SEZ-KD12KD15-NA
FBL1-3 FB Series Filter Box for SEZ-KD18NA
steel with foam gasket and provides an air-tight connection to indoor unit and access door Gasket material complies with UL 723 requirements
A screw-through cabinet design for secure attachment to indoor unit and return connection in rear is easily field-converted to bottom return
30 MITSUBISHI ELECTRIC
bull
bull
bull
bull
bull
bull
LINE-HIDE~ Put a professional finish on air-conditioning
installations with an easy-to-install modular
system that beautifies exteriors and
protects Linesets drainlines and wiring
Can be use it indoors too Meets UL94v-O for interior applications
Has snap-on covers and a full selection of couplings elbows T-joints caps and more for any application complex or simple
Offers high-quality PVC with UV inhibitors for outdoor service in all weather conditions
Can be painted with most house paints to match exterior decors
Is not just for HVAC Hide any exterior cabling piping or wiring
Available in four sizes 2-14 3 4 and 6 tubes
Download a brochure at wwwline-hidecom to find out more information
For more information on our CITY MULTI VRF product line visit our website at wwwmitsubishiprocom
_lIJrUlllln ~ ~IIII1 fInll l
~
l bull bull
JMITSUBISHI ELECTRIC 31
(SEZ-KD12NA MODEL SHOWN)
SEZ HEAT PUMP TAX
CREDIT
Model Name Indoor Unit SEZ-KD09NA4 SEZ-KD12NA4 SEZ-KD15NA4 SEZ-KD18NA4
Outdoor Unit SUZ-KA09NA SUZ-KA12NA SUZ-KA15NA SUZ-KA18NA Rated Capacity Btuh 8100 11500 14100 17200
Capacity Range Btuh 3800-10900 3800-13300 3800-17000 3800-19000
Cooling 1 Total Input W 670 920 1170 1380
Energy Efficiency SEER 15 16 155 175 Moisture Removal Pintsh 15 24 26 34 Sensible Heat Factor 080 076 080 079
Rated Capacity Btuh 10900 13600 18000 21600
Heating at 4YO F 2 Capacity Range Btuh 4800-14100 4800-16400 4800-21100 4800-24900
Total Input W 1020 1140 1500 1700 HSPF(lV) BtuhIW 100 Rated Capacity Btuh 6700 9000 11900 13100
Heating at 1 yo F 3 Rated Total Input W 810 920 1200 1350 Maximum Capacity Btuh 7300 9800 13700 15000
Power Supply Phase Cycle Voltage 1 Phase 60Hz 208 230V 4 Indoor - Outdoor S1 - S2 AC 208-230V
Voltage Indoor - Outdoor S2 - S3 DC 12-24V Indoor - Remote Controller See optional accessories chart (pg 26 and 27) MCA A 1 Fan Motor FLA 051 057 074
Airflow (Lo-Med-Hi) DRY (CFM) 194-247-317 247-317-388 353-441-529 423-529-635
WET (CFM) 174-222-285 222-285-349 317 -396-4 76 381-476-572 External Static Pressure 3 In wG 002-006-014-020 Sound Pressure Level dB(A) 23-26-30 23-28-33 30-34-37 30-34-38
Indoor Unit External Finish Galvanized-Steel Sheets
W In 31-18 39 46-78
Dimension Unit D In 27-916
H In 7-78
Weight Unit Lbs 42 50 54 62 Field Drainpipe Size 00 In 1-14
MCA A 12 14
MOCP A 15 Fan Motor FLA 050 093
Model DC Inverter DC Inverter Twin Rotary
I (Type)Compressor
RLA 66 74 10
LRA 82 93 125
Airflow (CoolingHeating) CFM 11511225 12291172 1 2431 229 17301659
Outdoor Unit Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(A) 46 49 54 Sound Pressure Level at Heating 2 dB(A) 50 51 56
External Finish Color Munsell No 3Y 7811
W In 31-12 33-16
Dimensions D In 11-14 13
H In 21-58 33-716
Weight Lbs 66 77 80 119 Remote Controller Type See optional accessories chart (pg 26 and 27)
Type R410A
Refrigerant Charge Lbs Oz 116 2 9
Type (fl Oil
oz) NE022 (108)
Refrigerant Pipe Gas Side OD In 38 Liquid Side 00 In 14
Refrigerant Pipe Height Difference (Max) Ft 40 Length Length (Max) Ft 65
Connection IndoorOutdoor FlaredFlared
Method
316
NE022 (152)
12
50
100
I
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg C) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F(8deg C) WB 43deg F(6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 17deg F(-8deg C) WB 15deg F(-9deg C) 4 Indoor units receive power from outdoor units through field-supplied interconnected wiring Specifications are subject to change without notice
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
14 MITSUBISHI ELECTRIC
SEZ STATIC PERFORMANCE CURVES (SEZ-KD12NA4 MODEL SHOWN)
SEZ-KD09NA4 SEZ-KD09NA4 (External static pressure O06[inwG]) 208230V 60Hz
[020] V L
5 [016
~l [0 12
]
SEZ-KD09NA4
~ ltij
~ [008
Jj
]
]
[004J ~
V V Middle
Low
V
19h
Rated point
1
o [141] [176J 1212) )247] [282J [318]
Airll ow rat e [CFM)
SEZ-KD12NA4 (External static pressure O06[inwG]) 208230V 60Hz
[020
5 [016
]
]
[353J
Limit
]
~ V
~ [ [0 12
u ltijJ[008
[004
]
_V ]~ Low
V
k-iddle
Rated POint
o [212) [247] [2 82] [318] [353] [388]
Airtlow rate [C FM]
SEZ-KD1SNA4 (External static pressure O06[inwGl) 208230V 60Hz
[424)
1020]
5 [016
~ ~ [012
~ ltij
~ [008
Jj
J
)
]
[004 ]
o
VV V [ Low
VV
vV High
Middle
I Rated point
[282] [318) [353] [388] [424] [459] [494] [530] [565J
Airllow rat e [CFM]
SEZ-KD18NA4 (External static pressure O06[inwG]) 208230V 60Hz
50 10 20]
] 40
5 [016
s 30 [ (012 )
ltij 20 ~ [008 )~Jj
10 [004]
V
Low
v Limit
rIV High
V [ Middle
~
1
Rated point
f318) [353) [388] [424] [459] [494] [530] [565] [600] [636] [671 )
Airllow rate [CFM]
(External static pressure O14[inwG]) 208230V 60Hz 80
[0 32
70 [028
5 60 [024
20 [0 08
10 [004
]
]
J
]
]
J
]V
]
U~it
V
k
High
~V Rated POI~1 V Middle Low
~
o [141] [1 76] 12121 )247J [282] [318]
Airtlow rate [CFM)
SEZ-KD12NA4 (External stat ic pressure O14[inwG]) 208230V 60Hz
[032]
[028J
5
[353]
J
~ [024
-~ [020] V-is
J V Il Hi9h Rated point
[016
~ ]
V V1 Middle
~ [012
[008]~
[004)
o [212)
[247)
SEZ-KD1SNA4
Low r
[282] [31 8) [353]
Airllow rale [CFM]
[388]
(External static pressure O14(inwG]) 208230V 60Hz
[032J
[424
]
2 V[028
5 [024]
V-i
] V High i [020
] K
Middle Rated point [0 16
g ]
~ -
QJj [0 12
J Low
[008
] I
~
[004
o [282J [318) [353J [388J [424) [459] [4 94] [530) [565)
Airt low rate [CFM]
SEZ-KD18NA4 (External statiC pressure O14(inwG]) 208230V 60Hz
1032
1028
~ 1024
-~ [0 20
is (0 16 ltij E ~ [012
(008
(004
o
I
]
]
)
]
)vlt ]
]
~ V
VV
Low
Limit
V
Ji9h
Middle l
Rated point
1 t
1
~ [318] [353] [388] [424] [459) [4 94] [530) [565) [600] [636] [671)
Airllow rate [CFM]
(External static pressure O20(inwG]) 208230V 60Hz
[032 ]
[028 J
5 [024
~ [020
is [016
1 [012Jj
[008
[004
J
]
]
] )
]
V Low
umz V High
~V
Rated point
Middle
1
[141] [176] [212) [247) [282) [318) [353J
Airtlow rat e [CFM]
SEZ-KD12NA4 (External static pressure O20(inwG]) 208230V 60H z
[032 ] LLimit
)
[0 28
5 ]
V
[024 -~ [020] V Rated point
Highis ~
) V
bull Middle
]~V I
[016
~ ~ [012
] Low
[008
]
[0 04
o [212) [247] [282] [318] [353] [388] [424]
Airllow rate [CFM]
SEZ-KD1SNA4 (External static pressure O20(inwG]) 208230V 60Hz
80 [032 ]
70 [0 28
~ [ O~~ -
ltij
E 30 ~ [0 12
20 [008
10 [004
o
)
J
]
]
JV
J
J
Limit V
LV High
V ~
K Rated point
Middle
VV 1gt
Low
I-
~ [282) [318) (353] (388) (424) 1459] [494] 15301 [565)
Airtlow rate [CFM]
SEZ-KD18NA4 (External static pressure O20[inwG]) 208230V 60Hz
[032
[028
~ [024sect
I [020
~ [016
~ Jj [0 12
[008
[004
o
]
)
]
]
]
~ )
]
]
1V
V 1
V
Low
1 limit
~~~ I ~~ High
~ R~ted pOini
Middle
1 1 -
[31 8) [353] [388] [424) [459] [494] [530] (565) [600] (636) [671J
Airllow rate [CFM)
Vl ~ ca (I)
I
N o ~ (I)
Vl m N Vl
-0 (I) n 3-i n QJ ~ o ~ tn
Note ESP 20S230V 60 Hz See manual for Static Performance Curve including 002 in WG
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts ~MITSUBISH[ ELECTRIC 15
SLZ HEAT PUMP (SLZ-KA12NA MODEL SHOWN)
Model Name Indoor Unit SLZ-KA09NA SLZ-KA12NA SLZ-KA15NA
Outdoor Unit SUZ-KA09NA SUZ-KA12NA SUZ-KA15NA Rated Capacity Btuh 8400 11100 15000
Capacity Range Btuh 3100-10900 3100-13300 3100-22200
Cooling 1 Total Input W 700 920 1460
Energy Efficiency SEER 15 154 16 Moisture Removal Pintsh 12 23 45 Sensible Heat Factor 080 076 080
Rated Capacity Btuh 10900 13 600 18000
Heating at 4r F 2 Capacity Range Btuh 3100-14100 3100-17100 3100-17100 Total Input W 930 1180 1950 HSPF (IV) BtuhIW 96 Rated Capacity Btuh 6200 8300 10200
Heating at 17deg F 3 Rated Total Input W 740 930 1310 Maximum Capacity Btuh 8300 10200 12000
Power Supply Phase Cycle Voltage 1 Phase 60Hz 208 230V 4 Indoor - Outdoor S1 - S2 AC 208-230V
Voltage Indoor - Outdoor S2 - S3 DC 12-24V
Indoor - Remote Controller See optional accessories chart (pg 26 and 27) MCA A 1 Fan Motor FLA 023 028 028
Airflow (Lo-Med-Hi) DRY (CFM) 280-320-350 280-320-390 280-320-390
WET (CFM) 250-290-320 250-290-350 250-290-350
Sound Pressure Level dB(Al 29-32-38 30-34-39 31-35-40
Indoor Unit External Finish Galvanized-Steel Sheets Grille Munsell 64Y 8904
W In 22-7 16 (25-58)
Dimension Unit (Grille) D In 22-716 (25-58
H In 8-316 (1316)
Weight Unit (Grille) Lbs 36 (7) Field Drainpipe Size 0 0 In 1-14 MCA A 12 MOCP A 15 Fan Motor FLA 050
Model (Type) DC INVERTER-driven DC INVERTER-driven
Compressor RLA 66
LRA 82
Airflow (CoolingHeating) CFM 11511225 1 229 1 172
Outdoor Unit Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(AJ 46 49 Sound Pressure Level at Heating 2 dB(AJ 50 51
External Finish Color Munsell No 3Y 781 1
W In 31 shy12
Dimensions 0 In 11-14
H In 21-58
Weight Lbs 66 77
~e R410A
Refrigerant Charge Lbs Oz 1 16
Oil Type (fl oz) NE022 108)
Refrigerant Pipe Gas Side 0 0 In 38 Liquid Side 00 In 14
Height Difference (Max) Ft 40 Refrigerant Pipe Length
Length (Max) Ft 65
Connection Method IndoorOutdoor FlaredFlared
29
Twin Rotary 74
93
12431 229
80
NE022 l152) 12
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg C) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F(8deg C) WB 43deg F(6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 17deg F(-8deg C) WB 15deg F(-9deg C) 4 Indoor units receive power from outdoor units through field-supplied interconnectedwiring Specifications are subject to change without notice
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
16 MITSUBISHI ELECTRIC
MHK1 WIRELESS REMOTE CONTROLLER KIT Exclusive for INVERTER-driven Mr Slimreg Systems VlWireless Technology a J
JMITSUBISHI ELECTRIC
Wireless Receiver
MHK1 Kit includes
09 mMRCH1 WIRELESS REMOTE CONTROLLER I Nbull Backlit easy-to-read display o
bull Dual setpoint control with system changeover J m
bull Enabled with RedLlNKTM reliability
bull Compatible with MCCH1 Vl Portable Central Controller m
N bull Installs Anywhere Vl
MFH1 WIRELESS RECEIVER N Vlbull Required for MRCH1 Wireless
CRemote Controller m bull Enabled with RedLiNK reliability n
31 n OJ o J en
SEZ and SLZ 11 systems with SUZ outdoor unit
Function Description
ONOFF OnOff operation for a single indoor unit
Operation Mode Cool I Drying I Auto I Heat I Fan only Available operation modes dependant on connected system
Temperature Setting Set temperature from 50degF - 8rF depending on operation mode and connected system
System Changeover Deadband Value 2-8degF
Schedule Operation 5-25-1-1
Fan Speed Setting HiMid-2Mid-1 IlowlAuto Available fan speed settings dependant on connected system
Air Flow Direction Setting Air flow angles 100deg - 80deg - 60deg - 40deg and oscilate Available air flow direction settings dependant on connected system
PermitProhibit Function Individual prohibit operations for each remote controller function (ONI OFF Set Temperature and Operation Mode)
Space Temperature Displays the measured space temperature
Error Indication Displays error code
Display Outside Temperature and Humidity
Requires optional MOS1 Outside Air Sensor
Dimensions - ryv x D x H) Remote Controller 5-316 x 1-12 x 3-916 Receiver 3-14 x 1-516 x 6-716
Operating Ambient Temperature Remote Controller 32 - 120degF Receiver -40 - 165degF
Operating Ambient Humidity Remote Controller 5 - 90 RH (non-condensing) Receiver 5 - 90 RH (non-condensing)
Power Supply 2 AA batteries
MRCH1 MIFH1 MRC1
Wireless Wall-Mounted Remote Controllers Wireless Receiver Cable
Accessories MCCH1 MOS1
Portable Central Controllers Outside Air Sensor
MITSUBISHI ELECTRIC 17
MULTIPLE ROOMS WITH INDIVIDUAL CONTROL FROM A SINGLE SYSTEM Enjoy ideal levels of comfort in the rooms you use most with our multi-room system Each room (zone) operates independently People in different rooms - the kitchen master bedroom or living room - can enjoy temperature settings that make each of them most comfortable
If you re looking for a complete comfort solution for several different rooms the MXZ multi-room system is the right choice The system is flexible enough to conform to a particular cooling and heating need and offers numerous different indoor unit combinations In addition up to eight indoor units can be connected to one outdoor unit Now with a SEZ horizontal ducted unit and a MFZ floorshystanding unit homeowners can enjoy an even greater range of zoning options provided by an MXZ system
An MXZ multi-room system is an excellent choice for supplementing capacity to a current system conditioning newly furnished spaces or new additions and replacing a system within a home Homeowners can also benefit from lower energy costs year-round while staying comfortable thanks to Mitsubishi Electrics energy-efficient technologies that are a part of every system that we make
To add to the level of energy efficiency the MXZ -2B20NA and MXZ -3B24NA systems qualify for both ENERGY STARreg and the federal tax credit (See details on page 21 for applicable indoor unit combinations)
At right a single level home with several system types represented (For illustrative purposes only)
MFZ Floor-Standing Indoor Units for MXZ Heat Pump Systems
Floor-standing indoor unit mounts three inches above the floor and has front panel access to the filter for ease of cleaning
The MFZ units provide energy-efficient solutions to provide personalized comfort for difficult areas that may be smaller or dont have usable space on the walls
MFZ units on MXZ systems include the following features bull Top and bottom discharge vanes bull Hot-start technology bull Quiet operation bull Wireless remote control (optional wall-mounted controller)
18 MITSUBISHI ELECTRIC
MSZ Wall-Mounted Indoor Units for MXZ Heat Pump Systems
Providing a wide range of cooling and heating capacities each wall-mounted indoor unit mounts high on a wall and connects to a branch box or the outdoor unit by a refrigerant line run via a 3 hole The MSZ units provide highly efficient solutions to cooling and heating needs and provide personalized comfort for the individual zones in which they are installed
MSZ units on MXZ systems include the following features bull Sleek flat panel design bull Hot-start technology bull Quiet operation bull i-seeM sensor technology (MSZ-FE0912NA models only) bull Enhanced filtration system (MSZ-FE0912NA models only) bull Wireless remote control (optional wired wall-mounted controller)
SLZ Ceiling-Recessed Indoor Units for MXZ Heat Pump Systems
The new SLZ-KA ceiling casette systems offer a wide air-flow pattern for better air distribution
offered to your customers Installation can be done in a hard ceiling (with a access panel for servicing) or placed into a 2x2 drop ceiling With a built-in drain lift mechanism for condensate
removal and a 4 ventilation air intake knockout option the SLZ is ready to handle a variety of installation needs
SLZ units on MXZ systems include the following features bull Wide air-flow pattern for better air distibution bull 4 ventillation air intake knockout bull Built-in condensate lift mechanism bull Wireless RedLlNKTM remote controller
SEZ Horizontal Ducted Indoor Units for MXZ Heat Pump Systems
SEZ ducted units can provide split air-conditioning system advantages with the added benefit of being concealed to provide virtually no visual footprint within the conditioned space other than a register and grille for the air to flow With the use of short run ductwork these units can provide comfort to a single room that needs air dispersed evenly throughout the space unusually shaped rooms and adjacent rooms
The SEZ unit on MXZ systems include the fOllvowin fatures _
g~e~~~~==Zl[bull Concealed design for short-run ductwork bull Quiet operation bull Built-in condensate lift mechanism
JMITSUBISHI ELECTRIC 19
s c t
I
N o J ro o ltro ~ ro ~
DIAMOND COMFORT MXZ MULTI-ZONE SYSTEMS MXZ-B Series multi-zone systems provide personalized comfort control and energy efficiency in up to eight rooms with only a single outdoor unit The MXZ-B Series system features include
bull Individual zone control bull Mix and match flexibility of indoor unit styles and combinations bull A wide range of indoor unit capacities that match the room size and requirements bull Flexible design options to tackle the most challenging multi-room installations bull Efficient systems including three systems [mxz series] that meet energy starltID and
federal tax credit requirements bull Simple quick and cost-effective installation keeps install costs down on new construction
and disruption to a minimum on renovations and refits
Efficiency and performance ratings depend on the number style and capacity of the indoor units installed with each Multi-Zone System
MXZ -2 B20 NA - 1 (2 1 ) MXZ -3 B24 NA (2 13 1) Ou tdoo r Unit Outdoor Uni t
MSZ-GE09NA Indoor Units
SEZ-KD12NA Indoor Unit
MSZ- GE06NA
~~~~li
(At least two indoor units MSZ-GE06NAIndoor Unit must be installed) Indoor Unit
(Two indoor units must be installed )
MXZ -3 B30 NA (2 1 3 1) Outdoor Unit
SEZ-KD12NA Indoor Unit
~~~i
(At least two indoor units MSZ-GE06NA must be installed)
Indoor Unit ~
MFZ- KD12NA Indoor Unit
MXZ-8B48NA (2 1-8 1) Outdoor Unit
(At least two indoor units
must be installed)
(At least two indoor units must be installed)
MFZ-KD09NA Indoor Units
MSZ-GE09NA Indoor Units
SEZ-KD12NA Indoor Unit
MSZ INDOOR UNIT
MSZ-FE18NA
PEAD HORIZONTAL -DUCTED INDOOR UNIT
PEAD-A24AA
MSZ INDOOR UNIT SEZ HORIZONTAL-DUCTED MSZ-FE18NA
INDOOR UNIT MFZ FLOOR-STANDING SEZ-KD18NA INDOOR UNIT
MFZ-KA12NA
20 AMITSUBISHI ELECTRIC
MULTI-ROOM MXZ-8 INVERTER HEAT PUMP R
Model Name Outdoor Unit MXZ-2B20NA-1 5 MXZ-3B24NA 6 MXZ-3B30NA MXZ-4B36NA 7
Indoor Unit
Cooling 1 Non-ductedl Ducted
Rated Capacity Btuh 1800020000 2200023600 28400127400 3540034400
Capacity Range Btuh 7800-20000 12600-25500 12600-28400 12600-36400
Total Input W 2190 (630-219QL 2460 (1000-2950) 3330 l1 000-3330) 3 940 (1 000-4020)
Heating at 4JO F 2 Non-ductedl Ducted
Rated Capacity Btuh 2200022000 2500024600 2860027600 3600034400
Capacity Range Btuh 8500-25500 11400-30600 11 400-36000 11400-43000
Total Input W 2620 (520-2620) 1900 (740-2600) 2220 (740-2820) 3100 (740-3940)
Heating at 1JO F 3 Non-ductedl Ducted
Rated Capacity Btuh 1250012500 1400014000 1600015100 2220020300
Rated Total Input W 13501430 13801570 21202 140 24302340
Maximum Capacity Btu h 1450014500 1880017000 1880018000 2460025400
Maximum Total Inl2ut W 15001590 21202230 21202140 33403450
Power Supply Phase Cycle Voltage 1-phase 60Hz 2081 230V 8
Voltage Indoor shy Outdoor S1 - S2 AC 2081 230V
Indoor shy Outdoor S2 - S3 DC12-24V
Outdoor Unit 4
MCA A 15 19
MOCP A 20
Fan Motor FLA 096 093
Compressor
Model (Type)
DC INVERTER-driven Twin Rotary
RLA 101 11 144
LRA 15
Airflow (CoolingHeating) CFM 14851 640 20681605 13651605 20682068
Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1
dB(A) 49 54 49 54
Sound Pressure Level at Heating 2
dB(A) 51 49 57
External Finish Color Munsell No 30Y 781 1
Dimensions
W In 33-116 35-716
D In 13 12-58
H In 27-1516 35-7116
Weight Lbs 130 150 153
Indoor Unit No of Units 2 23 23 234
Remote Controller Type Associated with the Indoor Unit
Refrigerant
Type R410A
Charge Lbs Oz 515 7 11 813
Oil Type (fl oz)
NE022 (237) NE022 (294)
Refrigerant Pipe Gas Side 00 In AB 38 A 12 BC 38 A 12 BCD 38
Liquid Side 00 In 14
Refrigerant Pipe Length Height Difference (Max) Ft 4933 9
Length (Max) Ft 164 (A+B) 230 (A+B+C) 230 (A+B+C+D)
Connection Method IndoorOutdoor FlaredlFlared
Compatible with the MSZ-A MSZ-GA MSZ-FD MSZ-FE MSZ-GE MFZ-KA and SEZ-KD series indoor units (PLA-18 amp PCA-24 on the MXZ-MXZ-3B PLA-24 amp PCA-24 on the MXZ-4B)
NOTES Test conditions are based on AHRI 210240 One indoor unit is turned off during low-speed testing under the new test conditions Systems actually exhibit higher energy efficiencies during normal operation
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F (35deg C) WB 75deg F (24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F (6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 600 F (160 C) Outdoor DB 17deg F (_80 C) WB 150 F (_90 C) 4 Refer to pages 12 and 13 for Indoor Unit specifications 5 Data from combination of two Indoor Units 9000 Btuh (non-ducted) or one 9000 Btuh and one 12000 Btuh (ducted) 6 Data from combination of two Indoor Units 6000 Btuh and one 9000 Btuh (non-ducted) or three 9000 Btuh (ducted) 7 Data from combination of four Indoor Units 9000 Btuh (non-ducted and ducted) 8 Indoor units receive power from outdoor units through field-supplied interconnected wiring 9 49 Applies to installations where the outdoor unit is installed below the indoor unit
Power factor equals 97 percent
Specifications are subject to change without notice
MULTI-ZONE ENERGY STAR AND TAX CREDIT SYSTEMS
Model Indoor Unit Combinations SEER HSPF
MXZ-2B20NA-1 2 x MSZ- GE09NA 18 8 9
MXZ- 3B24NA 2 x MSZ- GE06NA 1 x MSZshy GE09NA
17 5 9 3
MXZ- 3B24NA 2 x MSZ-GE06NA 1 x MSZ- GE12NA
17 5 93
For more details on all ENERGY STAR and tax credit systems go to wwwmitsubishicomfortcomtaxcredit
See page 25 for additional info on efficiency
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 21
MXZ-8B48NA THE ULTIMATE ZONING SOLUTION
The Mitsubishi Electric MXZ-S84SNA eight-zone unit As a member of the expanding MXZ-B Series of multi-zone systems the MXZ-8B outdoor unit incorporates branch boxes to connect up to eight indoor units MXZ- 8 B48 NA (2 1 - 8 1 )
Outd oor Uni t The INVERTER-driven compressor at the heart of the MXZ-8B -~-- shy
outdoor unit provides variable capacity control allowing the system to adjust to the specific demands of the interior space ~ as needed not the hard start and stop of a traditional system I[iDA Jinstalled in most US homes
The MXZ -8B48NA has only one port on the outdoor unit for two insulated refrigerant lines which run into the home or business to connect to a branch box or boxes From the branch box(es) gas and liquid refrigerant piping run to each of the indoor units The LEV in the branch box(es) controls the refrigerant flow as the load of each zone changes
Through the branch box(es) (the PAC-AKA31 BC three-port andor the PAC-AKA51 BC five-port) the system can connect from two indoor units up to eight indoor units depending on application requirements
The flexibility of the system doesnt stop there The MXZ-8B48NA has rated capacities of 48000 Btuh for cooling and 54000 Btuh for heating System operation however can range from a minimum 12000 Btuh to a maximum 54000 Btuh in cooling and a maximum of 60000 Btuh in heating This type of performance supports a large variety of applications
The MXZ-8B48NA allows for further flexibility because it supports a connected indoor unit capacity from 22 to 130 or 12000 Btuh to a maximum 70200 Btuh depending on diversity
Connectable Indoor Units General Features bull Four-ton outdoor unit can support up to
eight indoor units using branch boxes bull Wide variety of indoor unit styles
-=--_-=-----= - - J _ 1
including wall-mounted floor-standing MSZ-FE09 12 18NA MSZ-GE06 09 12 15 18 24NA ceiling-cassette ducted
bull Individual control up to eight (8) zones using wired or wireless controls
bull Advanced microprocessor control bull Auto restart following a power outage bull Self-check function offering SEZ-KD09 1215 18NA PEAD-A24AA
integrated diagnostics ~--- Jbull Limited warranty five years on parts and
defects and seven years on compressors
SLZ-KA09 1215NA MFZ-KA09 12 18NA
22 MITSUBISHI ELECTRIC LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
I
RMULTI-ROOM MXZ-8 INVERTER HEAT PUMP
Model Name Outdoor Unit MXZ-BB4BNA Cooling 1 Rated Capacity
Non-ducted Rated Total Input Ducted
Maximum Capacity
Rated CapacityHeating at
Rated Total InputIndoor Unit 4JO F 2 Non-
ductedDucted Maximum Capacity
Rated Capacity Heating at
Rated Total InputlJO F 3 Non-ductedDucted Maximum Capacity
Power Supply Phase Cycle Voltage
Indoor - Outdoor Sl - S2 Voltage
Indoor - Outdoor S2 - S3
MCA
Recommended FuseBreaker Size
Fan Motor
Compressor
Airflow (CoolingHeating)
Refrigerant Control
Outdoor Unit Sound Pressure Level at Cooling 1
Sound Pressure Level at Heating 2
External Finish Color
Dimensions
Weight
Total Capacity 22-130
Indoor Unit ModelQuantity
Remote Controller Type
Type
Refrigerant Charge
Oil
Gas Side OD Refrigerant Pipe
Liquid Side OD
Height Difference (Max)
Maximum Distance between (Outdoor unit and farthest indoor unit)
Refrigerant Pipe Length Maximum Pipe Length -Branch box to Indoor Unit
Total Maximum line length between Branch Box and All Connected Indoor Units
Total Length (Max)
Connection Method IndoorOutdoor
Includes both branch boxes if there are two
Branch Boxes (At least one branch box required)
Btuh
W
Btuh
Btuh
W
Btuh
Btuh
W
Btuh
A
A
Type x Quantity
Motor Output (kW)
Model (Type)
Motor Output (kW)
CFM
dB(A)
dB(A)
W In
D In
H In
Lbs
Btuh
Lbs Oz
Type (fl oz)
In
In
Ft
Ft
Ft
Ft
Ft
4800048000
57806470
54000
5400054000
48205270
60000
3300034700
29503390
3660036550
1 Phase 60Hz 208 230V
AC 208-230V
DC12-24V
32
40
Propeller x 2
0086 + 0086
DC INVERTER-driven Scroll
29
3530
Linear Expansion Valve
54
55
Munsell No 3Y 78 11
37-716
13+1-3 16
53-3 16
278
12000 - 70200
600 - 24000 2-8
Associated with Indoor Unit Model
R410A
18 112
FV50S (73)
58
38
6698 4
230
49
197
377
FlaredFlared
Compatible with the MSZ-A MSZ-FO MSZ-FE MSZ-GE MFZ-KA SEZ-KD PLA and PEAD series indoor units
NOTES Test conditions are based on AHRI 210240 One indoor unit is turned off during low-speed testing under the new test conditions Systems actually exhibit higher energy efficiencies during normal operation
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F (35deg C) WB 75deg F (24deg C)
2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 4]0 F (8deg C) WB 43deg F (6deg C)
3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 17deg F (-8deg C) WB 15deg F(-9deg C)
4 66 applies to installations when the outdoor unit is installed below the indoor unit
Power factor equals 97 percent
Specifications are subject to change without notice
Note Maximum installed capacity is the maximum total of all connected indoor units NOT the maximum capacity produced
Only a single Lineset is needed from the outdoor unit to branch box
See page 25 for MXZ-B information on efficiency
Required Branch Boxes for MXZ-SB4BNA (Maximum of 2 branch boxes can be connected to one outdoor unit requires joint MSDD-50AR-E or MSDD-50BR-E)
s c d N o J ro Vl
0 ro n 3i n OJ d o J U)
PAC-AKA51 BC Branch Box
PAC-AKA31 BC Branch Box LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 23
MSZ WALL-MOUNTED INDOOR UNITS (FOR MXZ-8 OUTDOOR UNITS)
R
(MSZ-GE12NA MODEL SHOWN)
-000 IIIIIII 9000 9000 12000 12000 14000 17200
Heating at 4r Rated Capacity Btuh 7200 10900 10900 14400 13600 18000 21600
F2 Power Supply I Phase Cycle Voltage J -phase 60Hz 208 230V 3
Iindoor Outdoor S1 S2 AC 208 230V
Iindoor Outdoor S2 S3 DC12-24V Voltage
Iindoor Remote vomr Iller Wireless Type (Optional Wired vomroller DC 12V)
IMCA A 10 IFan Motor FLA 076
DRY 162-226shy145-170shy
162-226shy205-272shy 230-275shy
Airflow at Cooling (CFM)
145-170-237-321-399 339-381
237 -321shy381-410
335-420shy 339-420shy(Quiet-Lo-Med-Hishy 399 533 533 Super Hi or Lo-Med-
WET 144-202shy109-134shy
144-202shy170-237shy 194-240shy
Fan Hi-Powerful)1 (CFM)
109-134-201-286-364 307-343
201-286shy350-367
300-385shy 304-385shy364 498 498
Airflow at Heating 145-170shy 145-170shy 145-170shy 205-247shy 230-275shy
(Quiet-Lo-Med-Hi- WET 233-321shy 237-321shy
166-240shy237-321shy
166-240shy304-367shy 339-431shy
Super Hi or Lo-Medshy (CFM) 406 406
367 -381 406
399-420 463 512
Hi-Powerful) 2 Sound Pressure Level at Cooling
19-22-30shy 26-32-38shy 28-33-38shy(Quiet-Lo-Med-Hi-Super Hi or Loshy dB(A) 19-22-30-37 -43 22-31-39-42
37-45 22-33-43-45
44-49 44-49Med-Hi-Powerful) 1
Sound Pressure Level at Heating 19-22-30shy 26-30-35shy 28-33-38shy
(Quiet-Lo-Med-Hi-Super Hi or Loshy dB(A) 19-22-30-37 -43 22-31-40-42 37-43
22-23-43-44 40-46 43-48
Med-Hi-Powerful) 2
I External Finish Color Munsell No 10Y 92 02
IWln 31 middot716
Dimension Unit 10 In 9 18 10-18 9middot18 10-18 9-18
IH In 11-58
I Weight Unit ILbs 22 27 22 27 22 I Field Drainpipe ~D lin 58 Remote Con-
Type Wireless Remote (Optional Wired Controller) troller
ITvpe B41QA Refrigerant ~s$ideOD lin 38 Pipe I Liquid Side 00 In 14
Connection IndoorOutdoor FlaredFlared
Method
1~
II 18000 22500
21600 27600
388-469shy 38$-469shy628-738 628-738
347-420shy 347-420shy562-661 562-661
388-469shy 388-469shy628-738 628-738
34-41-49-53 34-41-49-53
32-41-49-52 32-41-49-52
43-516
9-38
12-1316 37
58 38
MXZ-2B20NA is also compatible with the MSZ-A and MSZ-FD series indoor units NOTES Test conditions are based on AHRI 210240
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F(6deg C) 3 Indoor units receive power from outdoor units through field-supplied wiring
Specifications are subject to change without notice LIMITED WARRANTY Seven-year warranty on compressor Five-year warranty on parts For data on specific indoor unit combinations see page 21
SEZ DUCTED INDOOR UNIT (FOR MXZ-8 OUTDOOR UNITS)
I
Notes 1 Cooling-Indoor DS 80deg F(267deg C) WS 67deg F(194deg C) Outdoor DS 95deg F (35deg C) WS 75deg F(239deg C)
2 Heating-Indoor DS 70deg F(211 deg C) WS 60deg F(156deg C) Outdoor DS 47deg F (83deg C) WS 43deg F(61 deg C)
3 External static pressure is factory set to 006 WGAdjustable via the
1---------t---+-----L-------------1~---__I PAR-21MAA
1--_____----__________+-____---L____----~_____________1 4 Indoor units receive power
jE~~~~-------------r----1-----~-~~~~~~~~-----___1 from outdoor units through fieldsupplied interconnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven-year warranty on compressor Five-year
1---------------------+---+------------------------1 warranty on parts
~--__I_~----------+-------~l----------I For data on specific indoor unit combinations see page 21 - 23
I--~------+~-----------~----------r_------------I
- Reference page 17 for SEZ static performance curves
24 MITSUBISHI ELECTRIC
25-30-35-40 26-31-36-41 35-38-42-46
25-30-35-40 28-31-36-41 35-38-42-47
MFZ FLOORLOW WALL INDOOR UNIT (FOR middotMXZ-8 OUTDOOR UNITS)
------shy
-==
Airflow at Heating (CFM) 177-198-219-332 184-201-219-335 261-275-297-434
Voltage
Fan
Airflow at Cooling (Lo-Med-Hi-Super Hi)1
169-205-251-314 251-279-325-394
163-197-241-303 170-207-252-309 241-269-313-379
(Lo-Med-Hi-Super Hi) 2
SLZ CEILING-RECESSED INDOOR UNIT (FOR MXZ-8 OUTDOOR UNITS) EFFICIENCY RATINGS
Voltage
Fan
Galvanized-steel SheetsMunsell 64Y 89 04
Refrigerant Pipe
Model Indoor Unit Type SEER HSPF
MXZ-2B20NA-1
Non-dueted 18 89
Dueted and Non-dueted 1675 87
Dueted 155 85
MXZ-2B20NA-1 ENERGY STAR amp
TAX CREDIT 2 x MSZ-GE09NA 18 89
MXZ-3B24NA
lJon-dueted 175 93
Dueted and Non-dueted 1625 89
Dueted 150 85
MXZ-3B24NA ENERGY STAR amp
TAX CREDIT
2 x MSZ-GE06NA 1 x MSZ-GE09NA
175 93
MXZ-3B24NA ENERGY STAR amp
TAX CREDIT
2 x MSZ-GE06NA 1 x MSZ-GE12NA
175 93
MXZ-3B30NA
Non-dueted 175 105
Dueted and Non-dueted 16 100
Dueted 145 95
MXZ-4B36NA
Non-dueted 18 93
Dueted and Non-dueted 16 5 92
Dueted 150 9 0
MXZ-BB4BNA
Non-dueted 15 87
Dueted and Non-dueted 14B B8
Dueted 147 89
Connection IndoorOutdoor FlaredFlared
Method
Notes 1 Cooling-Indoor DB 80deg F(267deg C) WB 67deg F(194deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(239deg C) 2 Heating-Indoor DB 70deg F(21 1 deg C) WB 60deg F(156deg C) Outdoor DB 47deg F(83deg C) WB 43deg F(61 deg C) 3 Indoor units receive power from outdoor units through field supplied interconnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 25
Notes 1 Cooling-Indoor DB 80deg F(267deg C) WB 67deg F (194deg C) Outdoor DB 95deg F (35deg C)WB 75deg F (239deg C)
2 Heating-Indoor DB 70deg F(211deg C) WB 60deg F (156deg C) Outdoor DB 47 F (83deg C) WB 43deg F (61 deg C)
3 Indoor units receive power from outdoor units through field supplied interco(lnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven -year warranty on compressor Five-year warranty on parts
Presently there is no 1 1 system with the MFZ indoor unit
s c
N o J ro Vl
C ro n ~ n OJ t o J V)
M-SERIES RATING CONDITIONS
INDOOR INTAKE AIR TEMPERATURE
OUTDOOR INTAKE AIR TEMPERATURE
COOLING
MAXIMUM
95degF DB 71 degF WB (MU SUZ MXZ-2B20-13B243B304B36) 90degF DB 73degF WB (MUZY-GE MUZ-FE MUzy-D)
115degF DB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B24 3B304B368B48)
MINIMUM 67degF DB 57degF WB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B201 3B243B304B36)
14degF DB (MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B24 3B304B36) 23degF DB (MXZ-8B48) 6rF DB (MU)
MAXIMUM 80degF DB 6rF WB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B243B304B36)
75degF DB 65degF WB (MUZY-GE MUZY-GA24 MUZ-FE SUZ MXZ-2B20-1 3B243B304B36) 70degF DB (MXZ-8B48)
HEATING
MINIMUM 70degF DB 60degFWB (MUZ-GE MUZ-GA24 MUZ-D MUZ-FE SUZ MXZ-2B20-1 3B243B304B36)
-13degF DB -15degFWB (MUZ-FE) -4degF DB -5degF WB (SUZ MUZ-GE) 5degF DB 4degF WB (MUZ-GA24 MXZ-8B48NA) 6degF DB 5degF WB (MXZ-2B20-1 3B24 3B304B36) 14degF DB 13degFWB (MUZ-D)
MU units operate at intake air temperature down to 10deg Fwith the addition of an ICM-326HM-1 low temperature control
REFRIGERANT TUBING SETS
OPTIONAL ACCESSORIES
REFRIGERANT LINE LENGTH FLARE FLARE _INDOOR UNIT OUTDOOR UNIT
MS-A09WA MU-A09WA 35 MS-A12WA
65 MU-A12WA 35
MSY-GE09NA 65
MUY-GE09NA 40
MSY-GE12NA
65
MUY-GE12NA 65 40
MSY-GE15NA MUY-GE15NA 40
MSY-GE18NA
65
MUY-GE18NA 100 50
MSZ-GE09NA MUZ-GE09NA 65 40
MSZ-GE12NA MUZ-GE12NA 40
MSZ-GE15NA
65
MUZ-GE15NA 40
MSZ-GE18NA
65
MUZ-GE18NA 100 50
MSY-GE24NA MUY-GE24NA 100 50
MSZ-GE24NA MUZ-GE24NA 100 50
MSY-D30NA MUY-D30NA 100 50
MSZ-D30NA MUZ-D30NA 50
MSY-D36NA
100
MUY-D36NA 50
MSZ-D36NA
100
MUZ-D36NA 100 50
MSZ-FE09NA MUZ-FE09NA 40
MSZ-FE12NA
65
MUZ-FE12NA 40
MSZ-GE06091215NA MSZ-FE0912NA
65
MXZ-2B20NA-1 164 4933MFZ-KA0912NA SEZ-KD09 1215NA
MSZ-GE0609 121518NA MSZ-FE091218N MFZ-KA09 1218NA MXZ-3B24NA 164 4933 SEZ -KD09 12 15 18NA SLZ-KA09 12 15NA
MSZ-GE0609 121518NA MSZ-GA24NA MSZ-FE091218NA
MXZ-3B30NA 4933230MFZ-KA091218NA SEZ -KD09 121518NA SLZ-KA09 12 15NA
MSZ-GE0609121518NA MSZ-GE24NA MSZ-FE09 12 18NA
MXZ-4B36NA 230 4933MFZ-KA091218NA SEZ -KD09121518NA SLZ-KA09 12 15NA
MSZ-GE0609 12 15 18NA MSZ-GE24NA MSZ-FE09 12 18NA
MXZ-8B48NA 6698377MFZ-KA091218NA SEZ-KD09121518NA SLZ-KA09 12 15NA
PART NUMBER I USE WITH I DESCRIPTION
Port Adapters and Connection Pipes MAC-A454JP-E MXZ-Series Adapter 38 X12
MAC-A455JP-E MXZ-Series Adapter 12 X38
MAC-A456JP-E MXZ-Series Adapter 12 X58
MSDD-50AR-E MXZ-Series Branch Box Tee Distribution Pipe - Flare Connection between two branch boxes
MSDD-50BR-E MXZ-Series Branch Box Tee Distribution Pipe - Braze Connection between two branch boxes
PAC-493PI MXZ-Series Adapter 14 X38
PAC-SG76RJ-E MXZ-Series Adapter 38 X58
OPTIONAL ACCESSORIES CONTINUED ON NEXT PAGE
49 amp 66 applies to installations in which the outdoor unit is installed below indoor unit26 MITSUBISHI ELECTRIC
OPTIONAL ACCESSORIES (CONTINUED)
PART NUMBER USE WITH DESCRIPTION Control Options and Accessories
M21 JKO 307 M-Series Indoor Units Remote temperature sensor for M-Series indoor units
MAC-397IF-E
MAC-399IF-E
PAC-YU25HT
PAR-21 MM-G
M-Series INVERTER Units
M-Series INVERTER Units
SEZ-KD Indoor Units
Use with P-Series SEZ and for wired M-Series Controller
MA and contact terminal interface - Required to use PAR-21 MM wired wall mount controller with M-Series Systems
CMCN M-NET control adapter I Interface for Mr Slim M-Series MSYZ SEZ I MFZ
External Fan I Heater control relay adapter
Deluxe MA remote controller (Requires MAC-397IF-E for use with M-Series - MSYZ MFZ)
SEZ Wireless remote controller for SEZ units (Requires signal receiver PAR-SA9FA-E)PAR-FL32MA
PAR-SA9CA-E SEZ Wireless signal receiver for SEZ
3-pole disconnect switch 30A 600V turns off power between indoor and outdoor units shyM-SeriesTAZ-MS303
mounts in 2 X 4 utility box and requires standard single gang switch platecover - Low Ambient
ICM-326HM-2 M-Series Non-INVERTER units Low ambient head pressure controller MUZ-GE091215 IVIUZ-FE0912 SUZ-KD091215
Drain pan heaterMAC-640BH-U outdoor unit
MAC-641 BH-U MUZ-GE18 SUZ-KD18 outdoor unit Drain pan heater Filters
MAC-1415FT-E Anti-allergy enzyme filter
MAC-2300FT
MSZlMSY-D3036
Anti -allergy enzyme filter
MAC-308FT
MSYMSZ-GA24
MSZ-FD912 I FE0912 Platinum deodorizing filter
MAC-408FT-E Anti-allergy enzyme filter
MAC-415FT-E
M-Series Indoor Unit - GE09GE12GE15GE18
MFZ-KA Air Cleaning FilterAnti-Aliergy Enzyme Filter
MAC-418FT Anti-allergy enzyme filter
Filter Boxes
FBL1-1
MSZ- FD912 I FE091 2
FB Series Filter Box for SEZ-KD09NA Optional filter box with MERV 8 filters
FB Series Filter Box for SEZ-KD1215NAFBL1-2 Optional filter box with MERV 8 filters
and PEA-A 12M
FBL1-3 FB Series Filter Box for SEZ-KD18NA Optional filter box with MERV 8 filters
Pumps
SI1730-230 MSYZ - 30000 Btuh or greater Sauermann mini condensation pump 230V
S13100-115 MS-Series - non-INVERTER Sauermann mini condensation pump 115V
S13100-230 Sauermann mini condensation pump 230VMSYZ - Less than 30000 Btuh
Miscellaneous BRP-1 Bottom Return Plate for SEZ-KD09NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-2 Bottom Return Plate for SEZ-KD12KD15-NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-3 Bottom Return Plate for SEZ-KD18NA Converts low profile ducted indoor unit from rear return to bottom return
BV12FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderreglnsulated - 12
BV14FSI Use with any Mr Sl im multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 14
BV38FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 38
BV58FSI Use with any IVIr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 58
Condensing unit wall mounting brackets (set of 2) - 440 lb capacity painted steel NOTE CWMB1 IVIU and PU outdoor units Installer is responsible to select and provide suitable hardware and materials to insure proper
mount of bracket to wall
DSD-400N M-Series DiamondBacktrade Platform Stands MUZ-GE18 I MUZ(y)-03036 I
MAC-811DS Drain socket assemblySUZ-KA18
MAC-851DS MUZ-FD0912 Drain socket
MAC-855SG M-Series Air outlet guide
MAC-856SG M-Series Air outlet guide - MXZ-3B24 I 3B30 I 4B36 NA
MAC-860DS MUZ-GE091215 I MUZ-FE0912 Drain socket
MAC-889SG M-Series Air outlet guide- MXZ-2B20NA
MAC-S99SG M-Series Air outlet guide
PAC-SG59SG-E IVIXZ-SB4SNA Air outlet guide (1 piece) I MXZ-SB48NA (Requires 2 pieces)
PAC-SG61 DS-E MXZ-8B4SNA Drain socket - connector
PAC-SG64DP-E MXZ-SB48NA Drain pan
RCMKP1CB lVI-Series Wireless Lockdown bracket for remote controller
lILTRILlTE1 All M-Series Condensing unit mounting pad 16 x 36 x 3
MITSUBISHI ELECTRIC 27
MXZ-8 Series Port Adapter chart Port Adapter Unit Port
Combinations Required Size
MXZ-2B20NA-1
2-zone combinations wi NA
A 38 x both units s12K 14
1-MAC-A454JP-E B 38 x
6+15 14
9+15 1-MAC-A454JP-E
MXZ-3B24NA
All rated 2-zone combina-NA
A 12 x tions 14
All rated 3-zone combina-NA
B 38 x tions 14
C 38 x 14
MXZ-3B30NA
2-zone combinations wi at NA
A 12 x least one unit s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
9 + 24 14
3-zone combinations wi 1-MAC-A455JP-E
all units s12K
All other rated 3-zone NA
comb
MXZ-4B36NA
2-zone combinations wi at NA
A 12 x least one un it s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
6 + 24 14
1-MAC-A456JP-E D 38 x
9 + 24 14
3-zone combinations wi at NA
least two units s12K
3-zone combinations wi 1-MAC-A454JP-E
two units15K
6+6+24 or 6+9+24 1-MAC-A456JP-E
9+9+24 1-MAC-A456JP-E
4-zone combinations wi at 1-MAC-A455JP-E
least three units s12K
6+6+15+15 1-MAC-A454JP-E
6+6+15+15 1-MAC-A454JP-E
Note When using the Pu-A24BA PCA-A24KA or PEAD-A24AA two port adapter will be needed 1-MAC-A456JP-E (12 x 58) A port or 1-PACshySG76RJ-E (38 x 58) B C and D ports and 1-PAC493PI (14 x 38)
28 JMITSUBISHI ELECTRIC
6+6+246+9+24 6+12+249+9+24 9+12+24 or 12+12+24
6+15+24 6+18+24 9+15+249+18+24 12+15+24 or 12+18+24
15+15+24 15+18+24 or 18+18+24
15+24+24 or 18+24+24
Combinations of 4 or more zones
1-PAC-SG76RJ-E
See notes for application below
2
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
See notes for application below
PORT A =38 gas x 14 liquid
PORT B =38 gas x 14 liquid
PORT C =38 gas x 14 liquid
PORT A =38 gas x 14 liquid
PORT B = 38 gas x 14 liquid
PORT C = 38 gas x 14 liquid
PORT D =38 gas x 14 liquid
PORT E =12 gas x 14 liquid
Notes for application bull Check the lineset sizes for your indoor selected models bull Select the branch box or boxes needed for your application bull Compare indoor unit lineset sizes as compared to branch
box sizes bull Connect 15K + indoor units to the larger port on the
(PAC-AKA51 BC) bull Adapt lineset size with appropriate port adapter from
above list bull When using the PU-A24BA or PEAD-A24AA two port
adapter will be needed 1-MAC-A456JP-E (12 x 58) or 1-PAC-SG76RJ-E (38 x 58) and 1-PAC493PI (14 x 38)
-fv
~ DIAMONDBACKtrade
~) BV-Series Ball Valves Model numbers
BV14FFSI BV38FFSI
LISTED 891N REFRIGERANT
BV12FFSI VALVE bull Engineered for Mini-split andBV58FFSI
Multi-split HVAC Units bull Size available 14 38 12 58
bull Full Port Designbull Fully factory assembled bull Furnace brazed and pressure tested bull 700 PSIG Rated bull Each ball valve is equipped with Schraderreg Valve
for refrigerant service bull R-410A Compatible bull Design working pressure 700 PSIG bull Temperature range bull Flare Connections
-40 0 F to +3250 F (-400 C to + 1490
C) bull Forged brass body and seal cap bull Teflonreg seals and gaskets (no synthetic a-rings) bull Seal cap design permits valve operation without
removal of seal cap bull Suitable for use with R-11 R-22 R-123 R-125
R-134A R-236FA R-4202A R-402B R-404A R-407C R-410A R-500 R-502 and R-507
bull One year limited materials and workmanship
Part Number SAE Flare
A B C 0 E F
BV14FFSI 14 619 260 180 122 142 110
BV38FFSI 38 630 267 180 122 142 110
BV12FFSI 12 651 267 180 122 142 110
BV58FFSI 58 664 267 180 128 142 110
Ball valves come With an insulation piece warranty on Ball Valves
~ DIAMONDBACKtrade
~) Platform Stands
Lift the Mitsubishi Electric Comfort Solution
outdoor unit to new heights with our Diamondback Platform Stands
bull Easy to install
bull Available for all sizes of Mr Slim outdoor units
bull Color matched to the outdoor units
Model Number DSD-400N
L 15-34 x W 3-14 x H 3-14
r
)MITSUBISHI ELECTRIC 29
~ DIAMONDBACKtrade LINESETS
~~
Twin-Tube Lineset Insulation Design
bull Balanced outside diameter for uniform coiluncoil position stability
bull Minimum 12 insulation thickness on both tubes Diamondback Advantages include the following features
bull Quick efficient and economical field installation using factory applied Twin Tube insulation and flare connections with flare nuts mounted
bull Correct lengths for reducing waste and time
bull Quality consistency and economy
bull All Diamondback Lineset tubing is tested in accordance with ASTM E243
Filter Boxes
FB Series filter boxes are available in compatible sizes for all Mr Slim horizontal ducted indoor units
FBL 1 filter boxes include 1 thick pleated MERV 8 filter(s) installed Filters are tested in accordance with ANSIASHRAE Standard 522 and Rated Class 2 under UL Standard 900
The cabinet is constructed of non-insulated 20 gauge G-60 galvanized
FBL1-1 FB Series Filter Box for SEZ-KD09NA
FBL1-2 FB Series Filter Box for SEZ-KD12KD15-NA
FBL1-3 FB Series Filter Box for SEZ-KD18NA
steel with foam gasket and provides an air-tight connection to indoor unit and access door Gasket material complies with UL 723 requirements
A screw-through cabinet design for secure attachment to indoor unit and return connection in rear is easily field-converted to bottom return
30 MITSUBISHI ELECTRIC
bull
bull
bull
bull
bull
bull
LINE-HIDE~ Put a professional finish on air-conditioning
installations with an easy-to-install modular
system that beautifies exteriors and
protects Linesets drainlines and wiring
Can be use it indoors too Meets UL94v-O for interior applications
Has snap-on covers and a full selection of couplings elbows T-joints caps and more for any application complex or simple
Offers high-quality PVC with UV inhibitors for outdoor service in all weather conditions
Can be painted with most house paints to match exterior decors
Is not just for HVAC Hide any exterior cabling piping or wiring
Available in four sizes 2-14 3 4 and 6 tubes
Download a brochure at wwwline-hidecom to find out more information
For more information on our CITY MULTI VRF product line visit our website at wwwmitsubishiprocom
_lIJrUlllln ~ ~IIII1 fInll l
~
l bull bull
JMITSUBISHI ELECTRIC 31
SEZ STATIC PERFORMANCE CURVES (SEZ-KD12NA4 MODEL SHOWN)
SEZ-KD09NA4 SEZ-KD09NA4 (External static pressure O06[inwG]) 208230V 60Hz
[020] V L
5 [016
~l [0 12
]
SEZ-KD09NA4
~ ltij
~ [008
Jj
]
]
[004J ~
V V Middle
Low
V
19h
Rated point
1
o [141] [176J 1212) )247] [282J [318]
Airll ow rat e [CFM)
SEZ-KD12NA4 (External static pressure O06[inwG]) 208230V 60Hz
[020
5 [016
]
]
[353J
Limit
]
~ V
~ [ [0 12
u ltijJ[008
[004
]
_V ]~ Low
V
k-iddle
Rated POint
o [212) [247] [2 82] [318] [353] [388]
Airtlow rate [C FM]
SEZ-KD1SNA4 (External static pressure O06[inwGl) 208230V 60Hz
[424)
1020]
5 [016
~ ~ [012
~ ltij
~ [008
Jj
J
)
]
[004 ]
o
VV V [ Low
VV
vV High
Middle
I Rated point
[282] [318) [353] [388] [424] [459] [494] [530] [565J
Airllow rat e [CFM]
SEZ-KD18NA4 (External static pressure O06[inwG]) 208230V 60Hz
50 10 20]
] 40
5 [016
s 30 [ (012 )
ltij 20 ~ [008 )~Jj
10 [004]
V
Low
v Limit
rIV High
V [ Middle
~
1
Rated point
f318) [353) [388] [424] [459] [494] [530] [565] [600] [636] [671 )
Airllow rate [CFM]
(External static pressure O14[inwG]) 208230V 60Hz 80
[0 32
70 [028
5 60 [024
20 [0 08
10 [004
]
]
J
]
]
J
]V
]
U~it
V
k
High
~V Rated POI~1 V Middle Low
~
o [141] [1 76] 12121 )247J [282] [318]
Airtlow rate [CFM)
SEZ-KD12NA4 (External stat ic pressure O14[inwG]) 208230V 60Hz
[032]
[028J
5
[353]
J
~ [024
-~ [020] V-is
J V Il Hi9h Rated point
[016
~ ]
V V1 Middle
~ [012
[008]~
[004)
o [212)
[247)
SEZ-KD1SNA4
Low r
[282] [31 8) [353]
Airllow rale [CFM]
[388]
(External static pressure O14(inwG]) 208230V 60Hz
[032J
[424
]
2 V[028
5 [024]
V-i
] V High i [020
] K
Middle Rated point [0 16
g ]
~ -
QJj [0 12
J Low
[008
] I
~
[004
o [282J [318) [353J [388J [424) [459] [4 94] [530) [565)
Airt low rate [CFM]
SEZ-KD18NA4 (External statiC pressure O14(inwG]) 208230V 60Hz
1032
1028
~ 1024
-~ [0 20
is (0 16 ltij E ~ [012
(008
(004
o
I
]
]
)
]
)vlt ]
]
~ V
VV
Low
Limit
V
Ji9h
Middle l
Rated point
1 t
1
~ [318] [353] [388] [424] [459) [4 94] [530) [565) [600] [636] [671)
Airllow rate [CFM]
(External static pressure O20(inwG]) 208230V 60Hz
[032 ]
[028 J
5 [024
~ [020
is [016
1 [012Jj
[008
[004
J
]
]
] )
]
V Low
umz V High
~V
Rated point
Middle
1
[141] [176] [212) [247) [282) [318) [353J
Airtlow rat e [CFM]
SEZ-KD12NA4 (External static pressure O20(inwG]) 208230V 60H z
[032 ] LLimit
)
[0 28
5 ]
V
[024 -~ [020] V Rated point
Highis ~
) V
bull Middle
]~V I
[016
~ ~ [012
] Low
[008
]
[0 04
o [212) [247] [282] [318] [353] [388] [424]
Airllow rate [CFM]
SEZ-KD1SNA4 (External static pressure O20(inwG]) 208230V 60Hz
80 [032 ]
70 [0 28
~ [ O~~ -
ltij
E 30 ~ [0 12
20 [008
10 [004
o
)
J
]
]
JV
J
J
Limit V
LV High
V ~
K Rated point
Middle
VV 1gt
Low
I-
~ [282) [318) (353] (388) (424) 1459] [494] 15301 [565)
Airtlow rate [CFM]
SEZ-KD18NA4 (External static pressure O20[inwG]) 208230V 60Hz
[032
[028
~ [024sect
I [020
~ [016
~ Jj [0 12
[008
[004
o
]
)
]
]
]
~ )
]
]
1V
V 1
V
Low
1 limit
~~~ I ~~ High
~ R~ted pOini
Middle
1 1 -
[31 8) [353] [388] [424) [459] [494] [530] (565) [600] (636) [671J
Airllow rate [CFM)
Vl ~ ca (I)
I
N o ~ (I)
Vl m N Vl
-0 (I) n 3-i n QJ ~ o ~ tn
Note ESP 20S230V 60 Hz See manual for Static Performance Curve including 002 in WG
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts ~MITSUBISH[ ELECTRIC 15
SLZ HEAT PUMP (SLZ-KA12NA MODEL SHOWN)
Model Name Indoor Unit SLZ-KA09NA SLZ-KA12NA SLZ-KA15NA
Outdoor Unit SUZ-KA09NA SUZ-KA12NA SUZ-KA15NA Rated Capacity Btuh 8400 11100 15000
Capacity Range Btuh 3100-10900 3100-13300 3100-22200
Cooling 1 Total Input W 700 920 1460
Energy Efficiency SEER 15 154 16 Moisture Removal Pintsh 12 23 45 Sensible Heat Factor 080 076 080
Rated Capacity Btuh 10900 13 600 18000
Heating at 4r F 2 Capacity Range Btuh 3100-14100 3100-17100 3100-17100 Total Input W 930 1180 1950 HSPF (IV) BtuhIW 96 Rated Capacity Btuh 6200 8300 10200
Heating at 17deg F 3 Rated Total Input W 740 930 1310 Maximum Capacity Btuh 8300 10200 12000
Power Supply Phase Cycle Voltage 1 Phase 60Hz 208 230V 4 Indoor - Outdoor S1 - S2 AC 208-230V
Voltage Indoor - Outdoor S2 - S3 DC 12-24V
Indoor - Remote Controller See optional accessories chart (pg 26 and 27) MCA A 1 Fan Motor FLA 023 028 028
Airflow (Lo-Med-Hi) DRY (CFM) 280-320-350 280-320-390 280-320-390
WET (CFM) 250-290-320 250-290-350 250-290-350
Sound Pressure Level dB(Al 29-32-38 30-34-39 31-35-40
Indoor Unit External Finish Galvanized-Steel Sheets Grille Munsell 64Y 8904
W In 22-7 16 (25-58)
Dimension Unit (Grille) D In 22-716 (25-58
H In 8-316 (1316)
Weight Unit (Grille) Lbs 36 (7) Field Drainpipe Size 0 0 In 1-14 MCA A 12 MOCP A 15 Fan Motor FLA 050
Model (Type) DC INVERTER-driven DC INVERTER-driven
Compressor RLA 66
LRA 82
Airflow (CoolingHeating) CFM 11511225 1 229 1 172
Outdoor Unit Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(AJ 46 49 Sound Pressure Level at Heating 2 dB(AJ 50 51
External Finish Color Munsell No 3Y 781 1
W In 31 shy12
Dimensions 0 In 11-14
H In 21-58
Weight Lbs 66 77
~e R410A
Refrigerant Charge Lbs Oz 1 16
Oil Type (fl oz) NE022 108)
Refrigerant Pipe Gas Side 0 0 In 38 Liquid Side 00 In 14
Height Difference (Max) Ft 40 Refrigerant Pipe Length
Length (Max) Ft 65
Connection Method IndoorOutdoor FlaredFlared
29
Twin Rotary 74
93
12431 229
80
NE022 l152) 12
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg C) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F(8deg C) WB 43deg F(6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 17deg F(-8deg C) WB 15deg F(-9deg C) 4 Indoor units receive power from outdoor units through field-supplied interconnectedwiring Specifications are subject to change without notice
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
16 MITSUBISHI ELECTRIC
MHK1 WIRELESS REMOTE CONTROLLER KIT Exclusive for INVERTER-driven Mr Slimreg Systems VlWireless Technology a J
JMITSUBISHI ELECTRIC
Wireless Receiver
MHK1 Kit includes
09 mMRCH1 WIRELESS REMOTE CONTROLLER I Nbull Backlit easy-to-read display o
bull Dual setpoint control with system changeover J m
bull Enabled with RedLlNKTM reliability
bull Compatible with MCCH1 Vl Portable Central Controller m
N bull Installs Anywhere Vl
MFH1 WIRELESS RECEIVER N Vlbull Required for MRCH1 Wireless
CRemote Controller m bull Enabled with RedLiNK reliability n
31 n OJ o J en
SEZ and SLZ 11 systems with SUZ outdoor unit
Function Description
ONOFF OnOff operation for a single indoor unit
Operation Mode Cool I Drying I Auto I Heat I Fan only Available operation modes dependant on connected system
Temperature Setting Set temperature from 50degF - 8rF depending on operation mode and connected system
System Changeover Deadband Value 2-8degF
Schedule Operation 5-25-1-1
Fan Speed Setting HiMid-2Mid-1 IlowlAuto Available fan speed settings dependant on connected system
Air Flow Direction Setting Air flow angles 100deg - 80deg - 60deg - 40deg and oscilate Available air flow direction settings dependant on connected system
PermitProhibit Function Individual prohibit operations for each remote controller function (ONI OFF Set Temperature and Operation Mode)
Space Temperature Displays the measured space temperature
Error Indication Displays error code
Display Outside Temperature and Humidity
Requires optional MOS1 Outside Air Sensor
Dimensions - ryv x D x H) Remote Controller 5-316 x 1-12 x 3-916 Receiver 3-14 x 1-516 x 6-716
Operating Ambient Temperature Remote Controller 32 - 120degF Receiver -40 - 165degF
Operating Ambient Humidity Remote Controller 5 - 90 RH (non-condensing) Receiver 5 - 90 RH (non-condensing)
Power Supply 2 AA batteries
MRCH1 MIFH1 MRC1
Wireless Wall-Mounted Remote Controllers Wireless Receiver Cable
Accessories MCCH1 MOS1
Portable Central Controllers Outside Air Sensor
MITSUBISHI ELECTRIC 17
MULTIPLE ROOMS WITH INDIVIDUAL CONTROL FROM A SINGLE SYSTEM Enjoy ideal levels of comfort in the rooms you use most with our multi-room system Each room (zone) operates independently People in different rooms - the kitchen master bedroom or living room - can enjoy temperature settings that make each of them most comfortable
If you re looking for a complete comfort solution for several different rooms the MXZ multi-room system is the right choice The system is flexible enough to conform to a particular cooling and heating need and offers numerous different indoor unit combinations In addition up to eight indoor units can be connected to one outdoor unit Now with a SEZ horizontal ducted unit and a MFZ floorshystanding unit homeowners can enjoy an even greater range of zoning options provided by an MXZ system
An MXZ multi-room system is an excellent choice for supplementing capacity to a current system conditioning newly furnished spaces or new additions and replacing a system within a home Homeowners can also benefit from lower energy costs year-round while staying comfortable thanks to Mitsubishi Electrics energy-efficient technologies that are a part of every system that we make
To add to the level of energy efficiency the MXZ -2B20NA and MXZ -3B24NA systems qualify for both ENERGY STARreg and the federal tax credit (See details on page 21 for applicable indoor unit combinations)
At right a single level home with several system types represented (For illustrative purposes only)
MFZ Floor-Standing Indoor Units for MXZ Heat Pump Systems
Floor-standing indoor unit mounts three inches above the floor and has front panel access to the filter for ease of cleaning
The MFZ units provide energy-efficient solutions to provide personalized comfort for difficult areas that may be smaller or dont have usable space on the walls
MFZ units on MXZ systems include the following features bull Top and bottom discharge vanes bull Hot-start technology bull Quiet operation bull Wireless remote control (optional wall-mounted controller)
18 MITSUBISHI ELECTRIC
MSZ Wall-Mounted Indoor Units for MXZ Heat Pump Systems
Providing a wide range of cooling and heating capacities each wall-mounted indoor unit mounts high on a wall and connects to a branch box or the outdoor unit by a refrigerant line run via a 3 hole The MSZ units provide highly efficient solutions to cooling and heating needs and provide personalized comfort for the individual zones in which they are installed
MSZ units on MXZ systems include the following features bull Sleek flat panel design bull Hot-start technology bull Quiet operation bull i-seeM sensor technology (MSZ-FE0912NA models only) bull Enhanced filtration system (MSZ-FE0912NA models only) bull Wireless remote control (optional wired wall-mounted controller)
SLZ Ceiling-Recessed Indoor Units for MXZ Heat Pump Systems
The new SLZ-KA ceiling casette systems offer a wide air-flow pattern for better air distribution
offered to your customers Installation can be done in a hard ceiling (with a access panel for servicing) or placed into a 2x2 drop ceiling With a built-in drain lift mechanism for condensate
removal and a 4 ventilation air intake knockout option the SLZ is ready to handle a variety of installation needs
SLZ units on MXZ systems include the following features bull Wide air-flow pattern for better air distibution bull 4 ventillation air intake knockout bull Built-in condensate lift mechanism bull Wireless RedLlNKTM remote controller
SEZ Horizontal Ducted Indoor Units for MXZ Heat Pump Systems
SEZ ducted units can provide split air-conditioning system advantages with the added benefit of being concealed to provide virtually no visual footprint within the conditioned space other than a register and grille for the air to flow With the use of short run ductwork these units can provide comfort to a single room that needs air dispersed evenly throughout the space unusually shaped rooms and adjacent rooms
The SEZ unit on MXZ systems include the fOllvowin fatures _
g~e~~~~==Zl[bull Concealed design for short-run ductwork bull Quiet operation bull Built-in condensate lift mechanism
JMITSUBISHI ELECTRIC 19
s c t
I
N o J ro o ltro ~ ro ~
DIAMOND COMFORT MXZ MULTI-ZONE SYSTEMS MXZ-B Series multi-zone systems provide personalized comfort control and energy efficiency in up to eight rooms with only a single outdoor unit The MXZ-B Series system features include
bull Individual zone control bull Mix and match flexibility of indoor unit styles and combinations bull A wide range of indoor unit capacities that match the room size and requirements bull Flexible design options to tackle the most challenging multi-room installations bull Efficient systems including three systems [mxz series] that meet energy starltID and
federal tax credit requirements bull Simple quick and cost-effective installation keeps install costs down on new construction
and disruption to a minimum on renovations and refits
Efficiency and performance ratings depend on the number style and capacity of the indoor units installed with each Multi-Zone System
MXZ -2 B20 NA - 1 (2 1 ) MXZ -3 B24 NA (2 13 1) Ou tdoo r Unit Outdoor Uni t
MSZ-GE09NA Indoor Units
SEZ-KD12NA Indoor Unit
MSZ- GE06NA
~~~~li
(At least two indoor units MSZ-GE06NAIndoor Unit must be installed) Indoor Unit
(Two indoor units must be installed )
MXZ -3 B30 NA (2 1 3 1) Outdoor Unit
SEZ-KD12NA Indoor Unit
~~~i
(At least two indoor units MSZ-GE06NA must be installed)
Indoor Unit ~
MFZ- KD12NA Indoor Unit
MXZ-8B48NA (2 1-8 1) Outdoor Unit
(At least two indoor units
must be installed)
(At least two indoor units must be installed)
MFZ-KD09NA Indoor Units
MSZ-GE09NA Indoor Units
SEZ-KD12NA Indoor Unit
MSZ INDOOR UNIT
MSZ-FE18NA
PEAD HORIZONTAL -DUCTED INDOOR UNIT
PEAD-A24AA
MSZ INDOOR UNIT SEZ HORIZONTAL-DUCTED MSZ-FE18NA
INDOOR UNIT MFZ FLOOR-STANDING SEZ-KD18NA INDOOR UNIT
MFZ-KA12NA
20 AMITSUBISHI ELECTRIC
MULTI-ROOM MXZ-8 INVERTER HEAT PUMP R
Model Name Outdoor Unit MXZ-2B20NA-1 5 MXZ-3B24NA 6 MXZ-3B30NA MXZ-4B36NA 7
Indoor Unit
Cooling 1 Non-ductedl Ducted
Rated Capacity Btuh 1800020000 2200023600 28400127400 3540034400
Capacity Range Btuh 7800-20000 12600-25500 12600-28400 12600-36400
Total Input W 2190 (630-219QL 2460 (1000-2950) 3330 l1 000-3330) 3 940 (1 000-4020)
Heating at 4JO F 2 Non-ductedl Ducted
Rated Capacity Btuh 2200022000 2500024600 2860027600 3600034400
Capacity Range Btuh 8500-25500 11400-30600 11 400-36000 11400-43000
Total Input W 2620 (520-2620) 1900 (740-2600) 2220 (740-2820) 3100 (740-3940)
Heating at 1JO F 3 Non-ductedl Ducted
Rated Capacity Btuh 1250012500 1400014000 1600015100 2220020300
Rated Total Input W 13501430 13801570 21202 140 24302340
Maximum Capacity Btu h 1450014500 1880017000 1880018000 2460025400
Maximum Total Inl2ut W 15001590 21202230 21202140 33403450
Power Supply Phase Cycle Voltage 1-phase 60Hz 2081 230V 8
Voltage Indoor shy Outdoor S1 - S2 AC 2081 230V
Indoor shy Outdoor S2 - S3 DC12-24V
Outdoor Unit 4
MCA A 15 19
MOCP A 20
Fan Motor FLA 096 093
Compressor
Model (Type)
DC INVERTER-driven Twin Rotary
RLA 101 11 144
LRA 15
Airflow (CoolingHeating) CFM 14851 640 20681605 13651605 20682068
Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1
dB(A) 49 54 49 54
Sound Pressure Level at Heating 2
dB(A) 51 49 57
External Finish Color Munsell No 30Y 781 1
Dimensions
W In 33-116 35-716
D In 13 12-58
H In 27-1516 35-7116
Weight Lbs 130 150 153
Indoor Unit No of Units 2 23 23 234
Remote Controller Type Associated with the Indoor Unit
Refrigerant
Type R410A
Charge Lbs Oz 515 7 11 813
Oil Type (fl oz)
NE022 (237) NE022 (294)
Refrigerant Pipe Gas Side 00 In AB 38 A 12 BC 38 A 12 BCD 38
Liquid Side 00 In 14
Refrigerant Pipe Length Height Difference (Max) Ft 4933 9
Length (Max) Ft 164 (A+B) 230 (A+B+C) 230 (A+B+C+D)
Connection Method IndoorOutdoor FlaredlFlared
Compatible with the MSZ-A MSZ-GA MSZ-FD MSZ-FE MSZ-GE MFZ-KA and SEZ-KD series indoor units (PLA-18 amp PCA-24 on the MXZ-MXZ-3B PLA-24 amp PCA-24 on the MXZ-4B)
NOTES Test conditions are based on AHRI 210240 One indoor unit is turned off during low-speed testing under the new test conditions Systems actually exhibit higher energy efficiencies during normal operation
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F (35deg C) WB 75deg F (24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F (6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 600 F (160 C) Outdoor DB 17deg F (_80 C) WB 150 F (_90 C) 4 Refer to pages 12 and 13 for Indoor Unit specifications 5 Data from combination of two Indoor Units 9000 Btuh (non-ducted) or one 9000 Btuh and one 12000 Btuh (ducted) 6 Data from combination of two Indoor Units 6000 Btuh and one 9000 Btuh (non-ducted) or three 9000 Btuh (ducted) 7 Data from combination of four Indoor Units 9000 Btuh (non-ducted and ducted) 8 Indoor units receive power from outdoor units through field-supplied interconnected wiring 9 49 Applies to installations where the outdoor unit is installed below the indoor unit
Power factor equals 97 percent
Specifications are subject to change without notice
MULTI-ZONE ENERGY STAR AND TAX CREDIT SYSTEMS
Model Indoor Unit Combinations SEER HSPF
MXZ-2B20NA-1 2 x MSZ- GE09NA 18 8 9
MXZ- 3B24NA 2 x MSZ- GE06NA 1 x MSZshy GE09NA
17 5 9 3
MXZ- 3B24NA 2 x MSZ-GE06NA 1 x MSZ- GE12NA
17 5 93
For more details on all ENERGY STAR and tax credit systems go to wwwmitsubishicomfortcomtaxcredit
See page 25 for additional info on efficiency
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 21
MXZ-8B48NA THE ULTIMATE ZONING SOLUTION
The Mitsubishi Electric MXZ-S84SNA eight-zone unit As a member of the expanding MXZ-B Series of multi-zone systems the MXZ-8B outdoor unit incorporates branch boxes to connect up to eight indoor units MXZ- 8 B48 NA (2 1 - 8 1 )
Outd oor Uni t The INVERTER-driven compressor at the heart of the MXZ-8B -~-- shy
outdoor unit provides variable capacity control allowing the system to adjust to the specific demands of the interior space ~ as needed not the hard start and stop of a traditional system I[iDA Jinstalled in most US homes
The MXZ -8B48NA has only one port on the outdoor unit for two insulated refrigerant lines which run into the home or business to connect to a branch box or boxes From the branch box(es) gas and liquid refrigerant piping run to each of the indoor units The LEV in the branch box(es) controls the refrigerant flow as the load of each zone changes
Through the branch box(es) (the PAC-AKA31 BC three-port andor the PAC-AKA51 BC five-port) the system can connect from two indoor units up to eight indoor units depending on application requirements
The flexibility of the system doesnt stop there The MXZ-8B48NA has rated capacities of 48000 Btuh for cooling and 54000 Btuh for heating System operation however can range from a minimum 12000 Btuh to a maximum 54000 Btuh in cooling and a maximum of 60000 Btuh in heating This type of performance supports a large variety of applications
The MXZ-8B48NA allows for further flexibility because it supports a connected indoor unit capacity from 22 to 130 or 12000 Btuh to a maximum 70200 Btuh depending on diversity
Connectable Indoor Units General Features bull Four-ton outdoor unit can support up to
eight indoor units using branch boxes bull Wide variety of indoor unit styles
-=--_-=-----= - - J _ 1
including wall-mounted floor-standing MSZ-FE09 12 18NA MSZ-GE06 09 12 15 18 24NA ceiling-cassette ducted
bull Individual control up to eight (8) zones using wired or wireless controls
bull Advanced microprocessor control bull Auto restart following a power outage bull Self-check function offering SEZ-KD09 1215 18NA PEAD-A24AA
integrated diagnostics ~--- Jbull Limited warranty five years on parts and
defects and seven years on compressors
SLZ-KA09 1215NA MFZ-KA09 12 18NA
22 MITSUBISHI ELECTRIC LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
I
RMULTI-ROOM MXZ-8 INVERTER HEAT PUMP
Model Name Outdoor Unit MXZ-BB4BNA Cooling 1 Rated Capacity
Non-ducted Rated Total Input Ducted
Maximum Capacity
Rated CapacityHeating at
Rated Total InputIndoor Unit 4JO F 2 Non-
ductedDucted Maximum Capacity
Rated Capacity Heating at
Rated Total InputlJO F 3 Non-ductedDucted Maximum Capacity
Power Supply Phase Cycle Voltage
Indoor - Outdoor Sl - S2 Voltage
Indoor - Outdoor S2 - S3
MCA
Recommended FuseBreaker Size
Fan Motor
Compressor
Airflow (CoolingHeating)
Refrigerant Control
Outdoor Unit Sound Pressure Level at Cooling 1
Sound Pressure Level at Heating 2
External Finish Color
Dimensions
Weight
Total Capacity 22-130
Indoor Unit ModelQuantity
Remote Controller Type
Type
Refrigerant Charge
Oil
Gas Side OD Refrigerant Pipe
Liquid Side OD
Height Difference (Max)
Maximum Distance between (Outdoor unit and farthest indoor unit)
Refrigerant Pipe Length Maximum Pipe Length -Branch box to Indoor Unit
Total Maximum line length between Branch Box and All Connected Indoor Units
Total Length (Max)
Connection Method IndoorOutdoor
Includes both branch boxes if there are two
Branch Boxes (At least one branch box required)
Btuh
W
Btuh
Btuh
W
Btuh
Btuh
W
Btuh
A
A
Type x Quantity
Motor Output (kW)
Model (Type)
Motor Output (kW)
CFM
dB(A)
dB(A)
W In
D In
H In
Lbs
Btuh
Lbs Oz
Type (fl oz)
In
In
Ft
Ft
Ft
Ft
Ft
4800048000
57806470
54000
5400054000
48205270
60000
3300034700
29503390
3660036550
1 Phase 60Hz 208 230V
AC 208-230V
DC12-24V
32
40
Propeller x 2
0086 + 0086
DC INVERTER-driven Scroll
29
3530
Linear Expansion Valve
54
55
Munsell No 3Y 78 11
37-716
13+1-3 16
53-3 16
278
12000 - 70200
600 - 24000 2-8
Associated with Indoor Unit Model
R410A
18 112
FV50S (73)
58
38
6698 4
230
49
197
377
FlaredFlared
Compatible with the MSZ-A MSZ-FO MSZ-FE MSZ-GE MFZ-KA SEZ-KD PLA and PEAD series indoor units
NOTES Test conditions are based on AHRI 210240 One indoor unit is turned off during low-speed testing under the new test conditions Systems actually exhibit higher energy efficiencies during normal operation
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F (35deg C) WB 75deg F (24deg C)
2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 4]0 F (8deg C) WB 43deg F (6deg C)
3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 17deg F (-8deg C) WB 15deg F(-9deg C)
4 66 applies to installations when the outdoor unit is installed below the indoor unit
Power factor equals 97 percent
Specifications are subject to change without notice
Note Maximum installed capacity is the maximum total of all connected indoor units NOT the maximum capacity produced
Only a single Lineset is needed from the outdoor unit to branch box
See page 25 for MXZ-B information on efficiency
Required Branch Boxes for MXZ-SB4BNA (Maximum of 2 branch boxes can be connected to one outdoor unit requires joint MSDD-50AR-E or MSDD-50BR-E)
s c d N o J ro Vl
0 ro n 3i n OJ d o J U)
PAC-AKA51 BC Branch Box
PAC-AKA31 BC Branch Box LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 23
MSZ WALL-MOUNTED INDOOR UNITS (FOR MXZ-8 OUTDOOR UNITS)
R
(MSZ-GE12NA MODEL SHOWN)
-000 IIIIIII 9000 9000 12000 12000 14000 17200
Heating at 4r Rated Capacity Btuh 7200 10900 10900 14400 13600 18000 21600
F2 Power Supply I Phase Cycle Voltage J -phase 60Hz 208 230V 3
Iindoor Outdoor S1 S2 AC 208 230V
Iindoor Outdoor S2 S3 DC12-24V Voltage
Iindoor Remote vomr Iller Wireless Type (Optional Wired vomroller DC 12V)
IMCA A 10 IFan Motor FLA 076
DRY 162-226shy145-170shy
162-226shy205-272shy 230-275shy
Airflow at Cooling (CFM)
145-170-237-321-399 339-381
237 -321shy381-410
335-420shy 339-420shy(Quiet-Lo-Med-Hishy 399 533 533 Super Hi or Lo-Med-
WET 144-202shy109-134shy
144-202shy170-237shy 194-240shy
Fan Hi-Powerful)1 (CFM)
109-134-201-286-364 307-343
201-286shy350-367
300-385shy 304-385shy364 498 498
Airflow at Heating 145-170shy 145-170shy 145-170shy 205-247shy 230-275shy
(Quiet-Lo-Med-Hi- WET 233-321shy 237-321shy
166-240shy237-321shy
166-240shy304-367shy 339-431shy
Super Hi or Lo-Medshy (CFM) 406 406
367 -381 406
399-420 463 512
Hi-Powerful) 2 Sound Pressure Level at Cooling
19-22-30shy 26-32-38shy 28-33-38shy(Quiet-Lo-Med-Hi-Super Hi or Loshy dB(A) 19-22-30-37 -43 22-31-39-42
37-45 22-33-43-45
44-49 44-49Med-Hi-Powerful) 1
Sound Pressure Level at Heating 19-22-30shy 26-30-35shy 28-33-38shy
(Quiet-Lo-Med-Hi-Super Hi or Loshy dB(A) 19-22-30-37 -43 22-31-40-42 37-43
22-23-43-44 40-46 43-48
Med-Hi-Powerful) 2
I External Finish Color Munsell No 10Y 92 02
IWln 31 middot716
Dimension Unit 10 In 9 18 10-18 9middot18 10-18 9-18
IH In 11-58
I Weight Unit ILbs 22 27 22 27 22 I Field Drainpipe ~D lin 58 Remote Con-
Type Wireless Remote (Optional Wired Controller) troller
ITvpe B41QA Refrigerant ~s$ideOD lin 38 Pipe I Liquid Side 00 In 14
Connection IndoorOutdoor FlaredFlared
Method
1~
II 18000 22500
21600 27600
388-469shy 38$-469shy628-738 628-738
347-420shy 347-420shy562-661 562-661
388-469shy 388-469shy628-738 628-738
34-41-49-53 34-41-49-53
32-41-49-52 32-41-49-52
43-516
9-38
12-1316 37
58 38
MXZ-2B20NA is also compatible with the MSZ-A and MSZ-FD series indoor units NOTES Test conditions are based on AHRI 210240
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F(6deg C) 3 Indoor units receive power from outdoor units through field-supplied wiring
Specifications are subject to change without notice LIMITED WARRANTY Seven-year warranty on compressor Five-year warranty on parts For data on specific indoor unit combinations see page 21
SEZ DUCTED INDOOR UNIT (FOR MXZ-8 OUTDOOR UNITS)
I
Notes 1 Cooling-Indoor DS 80deg F(267deg C) WS 67deg F(194deg C) Outdoor DS 95deg F (35deg C) WS 75deg F(239deg C)
2 Heating-Indoor DS 70deg F(211 deg C) WS 60deg F(156deg C) Outdoor DS 47deg F (83deg C) WS 43deg F(61 deg C)
3 External static pressure is factory set to 006 WGAdjustable via the
1---------t---+-----L-------------1~---__I PAR-21MAA
1--_____----__________+-____---L____----~_____________1 4 Indoor units receive power
jE~~~~-------------r----1-----~-~~~~~~~~-----___1 from outdoor units through fieldsupplied interconnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven-year warranty on compressor Five-year
1---------------------+---+------------------------1 warranty on parts
~--__I_~----------+-------~l----------I For data on specific indoor unit combinations see page 21 - 23
I--~------+~-----------~----------r_------------I
- Reference page 17 for SEZ static performance curves
24 MITSUBISHI ELECTRIC
25-30-35-40 26-31-36-41 35-38-42-46
25-30-35-40 28-31-36-41 35-38-42-47
MFZ FLOORLOW WALL INDOOR UNIT (FOR middotMXZ-8 OUTDOOR UNITS)
------shy
-==
Airflow at Heating (CFM) 177-198-219-332 184-201-219-335 261-275-297-434
Voltage
Fan
Airflow at Cooling (Lo-Med-Hi-Super Hi)1
169-205-251-314 251-279-325-394
163-197-241-303 170-207-252-309 241-269-313-379
(Lo-Med-Hi-Super Hi) 2
SLZ CEILING-RECESSED INDOOR UNIT (FOR MXZ-8 OUTDOOR UNITS) EFFICIENCY RATINGS
Voltage
Fan
Galvanized-steel SheetsMunsell 64Y 89 04
Refrigerant Pipe
Model Indoor Unit Type SEER HSPF
MXZ-2B20NA-1
Non-dueted 18 89
Dueted and Non-dueted 1675 87
Dueted 155 85
MXZ-2B20NA-1 ENERGY STAR amp
TAX CREDIT 2 x MSZ-GE09NA 18 89
MXZ-3B24NA
lJon-dueted 175 93
Dueted and Non-dueted 1625 89
Dueted 150 85
MXZ-3B24NA ENERGY STAR amp
TAX CREDIT
2 x MSZ-GE06NA 1 x MSZ-GE09NA
175 93
MXZ-3B24NA ENERGY STAR amp
TAX CREDIT
2 x MSZ-GE06NA 1 x MSZ-GE12NA
175 93
MXZ-3B30NA
Non-dueted 175 105
Dueted and Non-dueted 16 100
Dueted 145 95
MXZ-4B36NA
Non-dueted 18 93
Dueted and Non-dueted 16 5 92
Dueted 150 9 0
MXZ-BB4BNA
Non-dueted 15 87
Dueted and Non-dueted 14B B8
Dueted 147 89
Connection IndoorOutdoor FlaredFlared
Method
Notes 1 Cooling-Indoor DB 80deg F(267deg C) WB 67deg F(194deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(239deg C) 2 Heating-Indoor DB 70deg F(21 1 deg C) WB 60deg F(156deg C) Outdoor DB 47deg F(83deg C) WB 43deg F(61 deg C) 3 Indoor units receive power from outdoor units through field supplied interconnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 25
Notes 1 Cooling-Indoor DB 80deg F(267deg C) WB 67deg F (194deg C) Outdoor DB 95deg F (35deg C)WB 75deg F (239deg C)
2 Heating-Indoor DB 70deg F(211deg C) WB 60deg F (156deg C) Outdoor DB 47 F (83deg C) WB 43deg F (61 deg C)
3 Indoor units receive power from outdoor units through field supplied interco(lnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven -year warranty on compressor Five-year warranty on parts
Presently there is no 1 1 system with the MFZ indoor unit
s c
N o J ro Vl
C ro n ~ n OJ t o J V)
M-SERIES RATING CONDITIONS
INDOOR INTAKE AIR TEMPERATURE
OUTDOOR INTAKE AIR TEMPERATURE
COOLING
MAXIMUM
95degF DB 71 degF WB (MU SUZ MXZ-2B20-13B243B304B36) 90degF DB 73degF WB (MUZY-GE MUZ-FE MUzy-D)
115degF DB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B24 3B304B368B48)
MINIMUM 67degF DB 57degF WB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B201 3B243B304B36)
14degF DB (MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B24 3B304B36) 23degF DB (MXZ-8B48) 6rF DB (MU)
MAXIMUM 80degF DB 6rF WB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B243B304B36)
75degF DB 65degF WB (MUZY-GE MUZY-GA24 MUZ-FE SUZ MXZ-2B20-1 3B243B304B36) 70degF DB (MXZ-8B48)
HEATING
MINIMUM 70degF DB 60degFWB (MUZ-GE MUZ-GA24 MUZ-D MUZ-FE SUZ MXZ-2B20-1 3B243B304B36)
-13degF DB -15degFWB (MUZ-FE) -4degF DB -5degF WB (SUZ MUZ-GE) 5degF DB 4degF WB (MUZ-GA24 MXZ-8B48NA) 6degF DB 5degF WB (MXZ-2B20-1 3B24 3B304B36) 14degF DB 13degFWB (MUZ-D)
MU units operate at intake air temperature down to 10deg Fwith the addition of an ICM-326HM-1 low temperature control
REFRIGERANT TUBING SETS
OPTIONAL ACCESSORIES
REFRIGERANT LINE LENGTH FLARE FLARE _INDOOR UNIT OUTDOOR UNIT
MS-A09WA MU-A09WA 35 MS-A12WA
65 MU-A12WA 35
MSY-GE09NA 65
MUY-GE09NA 40
MSY-GE12NA
65
MUY-GE12NA 65 40
MSY-GE15NA MUY-GE15NA 40
MSY-GE18NA
65
MUY-GE18NA 100 50
MSZ-GE09NA MUZ-GE09NA 65 40
MSZ-GE12NA MUZ-GE12NA 40
MSZ-GE15NA
65
MUZ-GE15NA 40
MSZ-GE18NA
65
MUZ-GE18NA 100 50
MSY-GE24NA MUY-GE24NA 100 50
MSZ-GE24NA MUZ-GE24NA 100 50
MSY-D30NA MUY-D30NA 100 50
MSZ-D30NA MUZ-D30NA 50
MSY-D36NA
100
MUY-D36NA 50
MSZ-D36NA
100
MUZ-D36NA 100 50
MSZ-FE09NA MUZ-FE09NA 40
MSZ-FE12NA
65
MUZ-FE12NA 40
MSZ-GE06091215NA MSZ-FE0912NA
65
MXZ-2B20NA-1 164 4933MFZ-KA0912NA SEZ-KD09 1215NA
MSZ-GE0609 121518NA MSZ-FE091218N MFZ-KA09 1218NA MXZ-3B24NA 164 4933 SEZ -KD09 12 15 18NA SLZ-KA09 12 15NA
MSZ-GE0609 121518NA MSZ-GA24NA MSZ-FE091218NA
MXZ-3B30NA 4933230MFZ-KA091218NA SEZ -KD09 121518NA SLZ-KA09 12 15NA
MSZ-GE0609121518NA MSZ-GE24NA MSZ-FE09 12 18NA
MXZ-4B36NA 230 4933MFZ-KA091218NA SEZ -KD09121518NA SLZ-KA09 12 15NA
MSZ-GE0609 12 15 18NA MSZ-GE24NA MSZ-FE09 12 18NA
MXZ-8B48NA 6698377MFZ-KA091218NA SEZ-KD09121518NA SLZ-KA09 12 15NA
PART NUMBER I USE WITH I DESCRIPTION
Port Adapters and Connection Pipes MAC-A454JP-E MXZ-Series Adapter 38 X12
MAC-A455JP-E MXZ-Series Adapter 12 X38
MAC-A456JP-E MXZ-Series Adapter 12 X58
MSDD-50AR-E MXZ-Series Branch Box Tee Distribution Pipe - Flare Connection between two branch boxes
MSDD-50BR-E MXZ-Series Branch Box Tee Distribution Pipe - Braze Connection between two branch boxes
PAC-493PI MXZ-Series Adapter 14 X38
PAC-SG76RJ-E MXZ-Series Adapter 38 X58
OPTIONAL ACCESSORIES CONTINUED ON NEXT PAGE
49 amp 66 applies to installations in which the outdoor unit is installed below indoor unit26 MITSUBISHI ELECTRIC
OPTIONAL ACCESSORIES (CONTINUED)
PART NUMBER USE WITH DESCRIPTION Control Options and Accessories
M21 JKO 307 M-Series Indoor Units Remote temperature sensor for M-Series indoor units
MAC-397IF-E
MAC-399IF-E
PAC-YU25HT
PAR-21 MM-G
M-Series INVERTER Units
M-Series INVERTER Units
SEZ-KD Indoor Units
Use with P-Series SEZ and for wired M-Series Controller
MA and contact terminal interface - Required to use PAR-21 MM wired wall mount controller with M-Series Systems
CMCN M-NET control adapter I Interface for Mr Slim M-Series MSYZ SEZ I MFZ
External Fan I Heater control relay adapter
Deluxe MA remote controller (Requires MAC-397IF-E for use with M-Series - MSYZ MFZ)
SEZ Wireless remote controller for SEZ units (Requires signal receiver PAR-SA9FA-E)PAR-FL32MA
PAR-SA9CA-E SEZ Wireless signal receiver for SEZ
3-pole disconnect switch 30A 600V turns off power between indoor and outdoor units shyM-SeriesTAZ-MS303
mounts in 2 X 4 utility box and requires standard single gang switch platecover - Low Ambient
ICM-326HM-2 M-Series Non-INVERTER units Low ambient head pressure controller MUZ-GE091215 IVIUZ-FE0912 SUZ-KD091215
Drain pan heaterMAC-640BH-U outdoor unit
MAC-641 BH-U MUZ-GE18 SUZ-KD18 outdoor unit Drain pan heater Filters
MAC-1415FT-E Anti-allergy enzyme filter
MAC-2300FT
MSZlMSY-D3036
Anti -allergy enzyme filter
MAC-308FT
MSYMSZ-GA24
MSZ-FD912 I FE0912 Platinum deodorizing filter
MAC-408FT-E Anti-allergy enzyme filter
MAC-415FT-E
M-Series Indoor Unit - GE09GE12GE15GE18
MFZ-KA Air Cleaning FilterAnti-Aliergy Enzyme Filter
MAC-418FT Anti-allergy enzyme filter
Filter Boxes
FBL1-1
MSZ- FD912 I FE091 2
FB Series Filter Box for SEZ-KD09NA Optional filter box with MERV 8 filters
FB Series Filter Box for SEZ-KD1215NAFBL1-2 Optional filter box with MERV 8 filters
and PEA-A 12M
FBL1-3 FB Series Filter Box for SEZ-KD18NA Optional filter box with MERV 8 filters
Pumps
SI1730-230 MSYZ - 30000 Btuh or greater Sauermann mini condensation pump 230V
S13100-115 MS-Series - non-INVERTER Sauermann mini condensation pump 115V
S13100-230 Sauermann mini condensation pump 230VMSYZ - Less than 30000 Btuh
Miscellaneous BRP-1 Bottom Return Plate for SEZ-KD09NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-2 Bottom Return Plate for SEZ-KD12KD15-NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-3 Bottom Return Plate for SEZ-KD18NA Converts low profile ducted indoor unit from rear return to bottom return
BV12FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderreglnsulated - 12
BV14FSI Use with any Mr Sl im multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 14
BV38FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 38
BV58FSI Use with any IVIr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 58
Condensing unit wall mounting brackets (set of 2) - 440 lb capacity painted steel NOTE CWMB1 IVIU and PU outdoor units Installer is responsible to select and provide suitable hardware and materials to insure proper
mount of bracket to wall
DSD-400N M-Series DiamondBacktrade Platform Stands MUZ-GE18 I MUZ(y)-03036 I
MAC-811DS Drain socket assemblySUZ-KA18
MAC-851DS MUZ-FD0912 Drain socket
MAC-855SG M-Series Air outlet guide
MAC-856SG M-Series Air outlet guide - MXZ-3B24 I 3B30 I 4B36 NA
MAC-860DS MUZ-GE091215 I MUZ-FE0912 Drain socket
MAC-889SG M-Series Air outlet guide- MXZ-2B20NA
MAC-S99SG M-Series Air outlet guide
PAC-SG59SG-E IVIXZ-SB4SNA Air outlet guide (1 piece) I MXZ-SB48NA (Requires 2 pieces)
PAC-SG61 DS-E MXZ-8B4SNA Drain socket - connector
PAC-SG64DP-E MXZ-SB48NA Drain pan
RCMKP1CB lVI-Series Wireless Lockdown bracket for remote controller
lILTRILlTE1 All M-Series Condensing unit mounting pad 16 x 36 x 3
MITSUBISHI ELECTRIC 27
MXZ-8 Series Port Adapter chart Port Adapter Unit Port
Combinations Required Size
MXZ-2B20NA-1
2-zone combinations wi NA
A 38 x both units s12K 14
1-MAC-A454JP-E B 38 x
6+15 14
9+15 1-MAC-A454JP-E
MXZ-3B24NA
All rated 2-zone combina-NA
A 12 x tions 14
All rated 3-zone combina-NA
B 38 x tions 14
C 38 x 14
MXZ-3B30NA
2-zone combinations wi at NA
A 12 x least one unit s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
9 + 24 14
3-zone combinations wi 1-MAC-A455JP-E
all units s12K
All other rated 3-zone NA
comb
MXZ-4B36NA
2-zone combinations wi at NA
A 12 x least one un it s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
6 + 24 14
1-MAC-A456JP-E D 38 x
9 + 24 14
3-zone combinations wi at NA
least two units s12K
3-zone combinations wi 1-MAC-A454JP-E
two units15K
6+6+24 or 6+9+24 1-MAC-A456JP-E
9+9+24 1-MAC-A456JP-E
4-zone combinations wi at 1-MAC-A455JP-E
least three units s12K
6+6+15+15 1-MAC-A454JP-E
6+6+15+15 1-MAC-A454JP-E
Note When using the Pu-A24BA PCA-A24KA or PEAD-A24AA two port adapter will be needed 1-MAC-A456JP-E (12 x 58) A port or 1-PACshySG76RJ-E (38 x 58) B C and D ports and 1-PAC493PI (14 x 38)
28 JMITSUBISHI ELECTRIC
6+6+246+9+24 6+12+249+9+24 9+12+24 or 12+12+24
6+15+24 6+18+24 9+15+249+18+24 12+15+24 or 12+18+24
15+15+24 15+18+24 or 18+18+24
15+24+24 or 18+24+24
Combinations of 4 or more zones
1-PAC-SG76RJ-E
See notes for application below
2
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
See notes for application below
PORT A =38 gas x 14 liquid
PORT B =38 gas x 14 liquid
PORT C =38 gas x 14 liquid
PORT A =38 gas x 14 liquid
PORT B = 38 gas x 14 liquid
PORT C = 38 gas x 14 liquid
PORT D =38 gas x 14 liquid
PORT E =12 gas x 14 liquid
Notes for application bull Check the lineset sizes for your indoor selected models bull Select the branch box or boxes needed for your application bull Compare indoor unit lineset sizes as compared to branch
box sizes bull Connect 15K + indoor units to the larger port on the
(PAC-AKA51 BC) bull Adapt lineset size with appropriate port adapter from
above list bull When using the PU-A24BA or PEAD-A24AA two port
adapter will be needed 1-MAC-A456JP-E (12 x 58) or 1-PAC-SG76RJ-E (38 x 58) and 1-PAC493PI (14 x 38)
-fv
~ DIAMONDBACKtrade
~) BV-Series Ball Valves Model numbers
BV14FFSI BV38FFSI
LISTED 891N REFRIGERANT
BV12FFSI VALVE bull Engineered for Mini-split andBV58FFSI
Multi-split HVAC Units bull Size available 14 38 12 58
bull Full Port Designbull Fully factory assembled bull Furnace brazed and pressure tested bull 700 PSIG Rated bull Each ball valve is equipped with Schraderreg Valve
for refrigerant service bull R-410A Compatible bull Design working pressure 700 PSIG bull Temperature range bull Flare Connections
-40 0 F to +3250 F (-400 C to + 1490
C) bull Forged brass body and seal cap bull Teflonreg seals and gaskets (no synthetic a-rings) bull Seal cap design permits valve operation without
removal of seal cap bull Suitable for use with R-11 R-22 R-123 R-125
R-134A R-236FA R-4202A R-402B R-404A R-407C R-410A R-500 R-502 and R-507
bull One year limited materials and workmanship
Part Number SAE Flare
A B C 0 E F
BV14FFSI 14 619 260 180 122 142 110
BV38FFSI 38 630 267 180 122 142 110
BV12FFSI 12 651 267 180 122 142 110
BV58FFSI 58 664 267 180 128 142 110
Ball valves come With an insulation piece warranty on Ball Valves
~ DIAMONDBACKtrade
~) Platform Stands
Lift the Mitsubishi Electric Comfort Solution
outdoor unit to new heights with our Diamondback Platform Stands
bull Easy to install
bull Available for all sizes of Mr Slim outdoor units
bull Color matched to the outdoor units
Model Number DSD-400N
L 15-34 x W 3-14 x H 3-14
r
)MITSUBISHI ELECTRIC 29
~ DIAMONDBACKtrade LINESETS
~~
Twin-Tube Lineset Insulation Design
bull Balanced outside diameter for uniform coiluncoil position stability
bull Minimum 12 insulation thickness on both tubes Diamondback Advantages include the following features
bull Quick efficient and economical field installation using factory applied Twin Tube insulation and flare connections with flare nuts mounted
bull Correct lengths for reducing waste and time
bull Quality consistency and economy
bull All Diamondback Lineset tubing is tested in accordance with ASTM E243
Filter Boxes
FB Series filter boxes are available in compatible sizes for all Mr Slim horizontal ducted indoor units
FBL 1 filter boxes include 1 thick pleated MERV 8 filter(s) installed Filters are tested in accordance with ANSIASHRAE Standard 522 and Rated Class 2 under UL Standard 900
The cabinet is constructed of non-insulated 20 gauge G-60 galvanized
FBL1-1 FB Series Filter Box for SEZ-KD09NA
FBL1-2 FB Series Filter Box for SEZ-KD12KD15-NA
FBL1-3 FB Series Filter Box for SEZ-KD18NA
steel with foam gasket and provides an air-tight connection to indoor unit and access door Gasket material complies with UL 723 requirements
A screw-through cabinet design for secure attachment to indoor unit and return connection in rear is easily field-converted to bottom return
30 MITSUBISHI ELECTRIC
bull
bull
bull
bull
bull
bull
LINE-HIDE~ Put a professional finish on air-conditioning
installations with an easy-to-install modular
system that beautifies exteriors and
protects Linesets drainlines and wiring
Can be use it indoors too Meets UL94v-O for interior applications
Has snap-on covers and a full selection of couplings elbows T-joints caps and more for any application complex or simple
Offers high-quality PVC with UV inhibitors for outdoor service in all weather conditions
Can be painted with most house paints to match exterior decors
Is not just for HVAC Hide any exterior cabling piping or wiring
Available in four sizes 2-14 3 4 and 6 tubes
Download a brochure at wwwline-hidecom to find out more information
For more information on our CITY MULTI VRF product line visit our website at wwwmitsubishiprocom
_lIJrUlllln ~ ~IIII1 fInll l
~
l bull bull
JMITSUBISHI ELECTRIC 31
SLZ HEAT PUMP (SLZ-KA12NA MODEL SHOWN)
Model Name Indoor Unit SLZ-KA09NA SLZ-KA12NA SLZ-KA15NA
Outdoor Unit SUZ-KA09NA SUZ-KA12NA SUZ-KA15NA Rated Capacity Btuh 8400 11100 15000
Capacity Range Btuh 3100-10900 3100-13300 3100-22200
Cooling 1 Total Input W 700 920 1460
Energy Efficiency SEER 15 154 16 Moisture Removal Pintsh 12 23 45 Sensible Heat Factor 080 076 080
Rated Capacity Btuh 10900 13 600 18000
Heating at 4r F 2 Capacity Range Btuh 3100-14100 3100-17100 3100-17100 Total Input W 930 1180 1950 HSPF (IV) BtuhIW 96 Rated Capacity Btuh 6200 8300 10200
Heating at 17deg F 3 Rated Total Input W 740 930 1310 Maximum Capacity Btuh 8300 10200 12000
Power Supply Phase Cycle Voltage 1 Phase 60Hz 208 230V 4 Indoor - Outdoor S1 - S2 AC 208-230V
Voltage Indoor - Outdoor S2 - S3 DC 12-24V
Indoor - Remote Controller See optional accessories chart (pg 26 and 27) MCA A 1 Fan Motor FLA 023 028 028
Airflow (Lo-Med-Hi) DRY (CFM) 280-320-350 280-320-390 280-320-390
WET (CFM) 250-290-320 250-290-350 250-290-350
Sound Pressure Level dB(Al 29-32-38 30-34-39 31-35-40
Indoor Unit External Finish Galvanized-Steel Sheets Grille Munsell 64Y 8904
W In 22-7 16 (25-58)
Dimension Unit (Grille) D In 22-716 (25-58
H In 8-316 (1316)
Weight Unit (Grille) Lbs 36 (7) Field Drainpipe Size 0 0 In 1-14 MCA A 12 MOCP A 15 Fan Motor FLA 050
Model (Type) DC INVERTER-driven DC INVERTER-driven
Compressor RLA 66
LRA 82
Airflow (CoolingHeating) CFM 11511225 1 229 1 172
Outdoor Unit Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1 dB(AJ 46 49 Sound Pressure Level at Heating 2 dB(AJ 50 51
External Finish Color Munsell No 3Y 781 1
W In 31 shy12
Dimensions 0 In 11-14
H In 21-58
Weight Lbs 66 77
~e R410A
Refrigerant Charge Lbs Oz 1 16
Oil Type (fl oz) NE022 108)
Refrigerant Pipe Gas Side 0 0 In 38 Liquid Side 00 In 14
Height Difference (Max) Ft 40 Refrigerant Pipe Length
Length (Max) Ft 65
Connection Method IndoorOutdoor FlaredFlared
29
Twin Rotary 74
93
12431 229
80
NE022 l152) 12
NOTES Test conditions are based on AHRI 210240 1 Rating conditions (cooling)-Indoor DB 80deg F(27deg C) WB 67deg F(19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F(8deg C) WB 43deg F(6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 17deg F(-8deg C) WB 15deg F(-9deg C) 4 Indoor units receive power from outdoor units through field-supplied interconnectedwiring Specifications are subject to change without notice
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
16 MITSUBISHI ELECTRIC
MHK1 WIRELESS REMOTE CONTROLLER KIT Exclusive for INVERTER-driven Mr Slimreg Systems VlWireless Technology a J
JMITSUBISHI ELECTRIC
Wireless Receiver
MHK1 Kit includes
09 mMRCH1 WIRELESS REMOTE CONTROLLER I Nbull Backlit easy-to-read display o
bull Dual setpoint control with system changeover J m
bull Enabled with RedLlNKTM reliability
bull Compatible with MCCH1 Vl Portable Central Controller m
N bull Installs Anywhere Vl
MFH1 WIRELESS RECEIVER N Vlbull Required for MRCH1 Wireless
CRemote Controller m bull Enabled with RedLiNK reliability n
31 n OJ o J en
SEZ and SLZ 11 systems with SUZ outdoor unit
Function Description
ONOFF OnOff operation for a single indoor unit
Operation Mode Cool I Drying I Auto I Heat I Fan only Available operation modes dependant on connected system
Temperature Setting Set temperature from 50degF - 8rF depending on operation mode and connected system
System Changeover Deadband Value 2-8degF
Schedule Operation 5-25-1-1
Fan Speed Setting HiMid-2Mid-1 IlowlAuto Available fan speed settings dependant on connected system
Air Flow Direction Setting Air flow angles 100deg - 80deg - 60deg - 40deg and oscilate Available air flow direction settings dependant on connected system
PermitProhibit Function Individual prohibit operations for each remote controller function (ONI OFF Set Temperature and Operation Mode)
Space Temperature Displays the measured space temperature
Error Indication Displays error code
Display Outside Temperature and Humidity
Requires optional MOS1 Outside Air Sensor
Dimensions - ryv x D x H) Remote Controller 5-316 x 1-12 x 3-916 Receiver 3-14 x 1-516 x 6-716
Operating Ambient Temperature Remote Controller 32 - 120degF Receiver -40 - 165degF
Operating Ambient Humidity Remote Controller 5 - 90 RH (non-condensing) Receiver 5 - 90 RH (non-condensing)
Power Supply 2 AA batteries
MRCH1 MIFH1 MRC1
Wireless Wall-Mounted Remote Controllers Wireless Receiver Cable
Accessories MCCH1 MOS1
Portable Central Controllers Outside Air Sensor
MITSUBISHI ELECTRIC 17
MULTIPLE ROOMS WITH INDIVIDUAL CONTROL FROM A SINGLE SYSTEM Enjoy ideal levels of comfort in the rooms you use most with our multi-room system Each room (zone) operates independently People in different rooms - the kitchen master bedroom or living room - can enjoy temperature settings that make each of them most comfortable
If you re looking for a complete comfort solution for several different rooms the MXZ multi-room system is the right choice The system is flexible enough to conform to a particular cooling and heating need and offers numerous different indoor unit combinations In addition up to eight indoor units can be connected to one outdoor unit Now with a SEZ horizontal ducted unit and a MFZ floorshystanding unit homeowners can enjoy an even greater range of zoning options provided by an MXZ system
An MXZ multi-room system is an excellent choice for supplementing capacity to a current system conditioning newly furnished spaces or new additions and replacing a system within a home Homeowners can also benefit from lower energy costs year-round while staying comfortable thanks to Mitsubishi Electrics energy-efficient technologies that are a part of every system that we make
To add to the level of energy efficiency the MXZ -2B20NA and MXZ -3B24NA systems qualify for both ENERGY STARreg and the federal tax credit (See details on page 21 for applicable indoor unit combinations)
At right a single level home with several system types represented (For illustrative purposes only)
MFZ Floor-Standing Indoor Units for MXZ Heat Pump Systems
Floor-standing indoor unit mounts three inches above the floor and has front panel access to the filter for ease of cleaning
The MFZ units provide energy-efficient solutions to provide personalized comfort for difficult areas that may be smaller or dont have usable space on the walls
MFZ units on MXZ systems include the following features bull Top and bottom discharge vanes bull Hot-start technology bull Quiet operation bull Wireless remote control (optional wall-mounted controller)
18 MITSUBISHI ELECTRIC
MSZ Wall-Mounted Indoor Units for MXZ Heat Pump Systems
Providing a wide range of cooling and heating capacities each wall-mounted indoor unit mounts high on a wall and connects to a branch box or the outdoor unit by a refrigerant line run via a 3 hole The MSZ units provide highly efficient solutions to cooling and heating needs and provide personalized comfort for the individual zones in which they are installed
MSZ units on MXZ systems include the following features bull Sleek flat panel design bull Hot-start technology bull Quiet operation bull i-seeM sensor technology (MSZ-FE0912NA models only) bull Enhanced filtration system (MSZ-FE0912NA models only) bull Wireless remote control (optional wired wall-mounted controller)
SLZ Ceiling-Recessed Indoor Units for MXZ Heat Pump Systems
The new SLZ-KA ceiling casette systems offer a wide air-flow pattern for better air distribution
offered to your customers Installation can be done in a hard ceiling (with a access panel for servicing) or placed into a 2x2 drop ceiling With a built-in drain lift mechanism for condensate
removal and a 4 ventilation air intake knockout option the SLZ is ready to handle a variety of installation needs
SLZ units on MXZ systems include the following features bull Wide air-flow pattern for better air distibution bull 4 ventillation air intake knockout bull Built-in condensate lift mechanism bull Wireless RedLlNKTM remote controller
SEZ Horizontal Ducted Indoor Units for MXZ Heat Pump Systems
SEZ ducted units can provide split air-conditioning system advantages with the added benefit of being concealed to provide virtually no visual footprint within the conditioned space other than a register and grille for the air to flow With the use of short run ductwork these units can provide comfort to a single room that needs air dispersed evenly throughout the space unusually shaped rooms and adjacent rooms
The SEZ unit on MXZ systems include the fOllvowin fatures _
g~e~~~~==Zl[bull Concealed design for short-run ductwork bull Quiet operation bull Built-in condensate lift mechanism
JMITSUBISHI ELECTRIC 19
s c t
I
N o J ro o ltro ~ ro ~
DIAMOND COMFORT MXZ MULTI-ZONE SYSTEMS MXZ-B Series multi-zone systems provide personalized comfort control and energy efficiency in up to eight rooms with only a single outdoor unit The MXZ-B Series system features include
bull Individual zone control bull Mix and match flexibility of indoor unit styles and combinations bull A wide range of indoor unit capacities that match the room size and requirements bull Flexible design options to tackle the most challenging multi-room installations bull Efficient systems including three systems [mxz series] that meet energy starltID and
federal tax credit requirements bull Simple quick and cost-effective installation keeps install costs down on new construction
and disruption to a minimum on renovations and refits
Efficiency and performance ratings depend on the number style and capacity of the indoor units installed with each Multi-Zone System
MXZ -2 B20 NA - 1 (2 1 ) MXZ -3 B24 NA (2 13 1) Ou tdoo r Unit Outdoor Uni t
MSZ-GE09NA Indoor Units
SEZ-KD12NA Indoor Unit
MSZ- GE06NA
~~~~li
(At least two indoor units MSZ-GE06NAIndoor Unit must be installed) Indoor Unit
(Two indoor units must be installed )
MXZ -3 B30 NA (2 1 3 1) Outdoor Unit
SEZ-KD12NA Indoor Unit
~~~i
(At least two indoor units MSZ-GE06NA must be installed)
Indoor Unit ~
MFZ- KD12NA Indoor Unit
MXZ-8B48NA (2 1-8 1) Outdoor Unit
(At least two indoor units
must be installed)
(At least two indoor units must be installed)
MFZ-KD09NA Indoor Units
MSZ-GE09NA Indoor Units
SEZ-KD12NA Indoor Unit
MSZ INDOOR UNIT
MSZ-FE18NA
PEAD HORIZONTAL -DUCTED INDOOR UNIT
PEAD-A24AA
MSZ INDOOR UNIT SEZ HORIZONTAL-DUCTED MSZ-FE18NA
INDOOR UNIT MFZ FLOOR-STANDING SEZ-KD18NA INDOOR UNIT
MFZ-KA12NA
20 AMITSUBISHI ELECTRIC
MULTI-ROOM MXZ-8 INVERTER HEAT PUMP R
Model Name Outdoor Unit MXZ-2B20NA-1 5 MXZ-3B24NA 6 MXZ-3B30NA MXZ-4B36NA 7
Indoor Unit
Cooling 1 Non-ductedl Ducted
Rated Capacity Btuh 1800020000 2200023600 28400127400 3540034400
Capacity Range Btuh 7800-20000 12600-25500 12600-28400 12600-36400
Total Input W 2190 (630-219QL 2460 (1000-2950) 3330 l1 000-3330) 3 940 (1 000-4020)
Heating at 4JO F 2 Non-ductedl Ducted
Rated Capacity Btuh 2200022000 2500024600 2860027600 3600034400
Capacity Range Btuh 8500-25500 11400-30600 11 400-36000 11400-43000
Total Input W 2620 (520-2620) 1900 (740-2600) 2220 (740-2820) 3100 (740-3940)
Heating at 1JO F 3 Non-ductedl Ducted
Rated Capacity Btuh 1250012500 1400014000 1600015100 2220020300
Rated Total Input W 13501430 13801570 21202 140 24302340
Maximum Capacity Btu h 1450014500 1880017000 1880018000 2460025400
Maximum Total Inl2ut W 15001590 21202230 21202140 33403450
Power Supply Phase Cycle Voltage 1-phase 60Hz 2081 230V 8
Voltage Indoor shy Outdoor S1 - S2 AC 2081 230V
Indoor shy Outdoor S2 - S3 DC12-24V
Outdoor Unit 4
MCA A 15 19
MOCP A 20
Fan Motor FLA 096 093
Compressor
Model (Type)
DC INVERTER-driven Twin Rotary
RLA 101 11 144
LRA 15
Airflow (CoolingHeating) CFM 14851 640 20681605 13651605 20682068
Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1
dB(A) 49 54 49 54
Sound Pressure Level at Heating 2
dB(A) 51 49 57
External Finish Color Munsell No 30Y 781 1
Dimensions
W In 33-116 35-716
D In 13 12-58
H In 27-1516 35-7116
Weight Lbs 130 150 153
Indoor Unit No of Units 2 23 23 234
Remote Controller Type Associated with the Indoor Unit
Refrigerant
Type R410A
Charge Lbs Oz 515 7 11 813
Oil Type (fl oz)
NE022 (237) NE022 (294)
Refrigerant Pipe Gas Side 00 In AB 38 A 12 BC 38 A 12 BCD 38
Liquid Side 00 In 14
Refrigerant Pipe Length Height Difference (Max) Ft 4933 9
Length (Max) Ft 164 (A+B) 230 (A+B+C) 230 (A+B+C+D)
Connection Method IndoorOutdoor FlaredlFlared
Compatible with the MSZ-A MSZ-GA MSZ-FD MSZ-FE MSZ-GE MFZ-KA and SEZ-KD series indoor units (PLA-18 amp PCA-24 on the MXZ-MXZ-3B PLA-24 amp PCA-24 on the MXZ-4B)
NOTES Test conditions are based on AHRI 210240 One indoor unit is turned off during low-speed testing under the new test conditions Systems actually exhibit higher energy efficiencies during normal operation
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F (35deg C) WB 75deg F (24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F (6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 600 F (160 C) Outdoor DB 17deg F (_80 C) WB 150 F (_90 C) 4 Refer to pages 12 and 13 for Indoor Unit specifications 5 Data from combination of two Indoor Units 9000 Btuh (non-ducted) or one 9000 Btuh and one 12000 Btuh (ducted) 6 Data from combination of two Indoor Units 6000 Btuh and one 9000 Btuh (non-ducted) or three 9000 Btuh (ducted) 7 Data from combination of four Indoor Units 9000 Btuh (non-ducted and ducted) 8 Indoor units receive power from outdoor units through field-supplied interconnected wiring 9 49 Applies to installations where the outdoor unit is installed below the indoor unit
Power factor equals 97 percent
Specifications are subject to change without notice
MULTI-ZONE ENERGY STAR AND TAX CREDIT SYSTEMS
Model Indoor Unit Combinations SEER HSPF
MXZ-2B20NA-1 2 x MSZ- GE09NA 18 8 9
MXZ- 3B24NA 2 x MSZ- GE06NA 1 x MSZshy GE09NA
17 5 9 3
MXZ- 3B24NA 2 x MSZ-GE06NA 1 x MSZ- GE12NA
17 5 93
For more details on all ENERGY STAR and tax credit systems go to wwwmitsubishicomfortcomtaxcredit
See page 25 for additional info on efficiency
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 21
MXZ-8B48NA THE ULTIMATE ZONING SOLUTION
The Mitsubishi Electric MXZ-S84SNA eight-zone unit As a member of the expanding MXZ-B Series of multi-zone systems the MXZ-8B outdoor unit incorporates branch boxes to connect up to eight indoor units MXZ- 8 B48 NA (2 1 - 8 1 )
Outd oor Uni t The INVERTER-driven compressor at the heart of the MXZ-8B -~-- shy
outdoor unit provides variable capacity control allowing the system to adjust to the specific demands of the interior space ~ as needed not the hard start and stop of a traditional system I[iDA Jinstalled in most US homes
The MXZ -8B48NA has only one port on the outdoor unit for two insulated refrigerant lines which run into the home or business to connect to a branch box or boxes From the branch box(es) gas and liquid refrigerant piping run to each of the indoor units The LEV in the branch box(es) controls the refrigerant flow as the load of each zone changes
Through the branch box(es) (the PAC-AKA31 BC three-port andor the PAC-AKA51 BC five-port) the system can connect from two indoor units up to eight indoor units depending on application requirements
The flexibility of the system doesnt stop there The MXZ-8B48NA has rated capacities of 48000 Btuh for cooling and 54000 Btuh for heating System operation however can range from a minimum 12000 Btuh to a maximum 54000 Btuh in cooling and a maximum of 60000 Btuh in heating This type of performance supports a large variety of applications
The MXZ-8B48NA allows for further flexibility because it supports a connected indoor unit capacity from 22 to 130 or 12000 Btuh to a maximum 70200 Btuh depending on diversity
Connectable Indoor Units General Features bull Four-ton outdoor unit can support up to
eight indoor units using branch boxes bull Wide variety of indoor unit styles
-=--_-=-----= - - J _ 1
including wall-mounted floor-standing MSZ-FE09 12 18NA MSZ-GE06 09 12 15 18 24NA ceiling-cassette ducted
bull Individual control up to eight (8) zones using wired or wireless controls
bull Advanced microprocessor control bull Auto restart following a power outage bull Self-check function offering SEZ-KD09 1215 18NA PEAD-A24AA
integrated diagnostics ~--- Jbull Limited warranty five years on parts and
defects and seven years on compressors
SLZ-KA09 1215NA MFZ-KA09 12 18NA
22 MITSUBISHI ELECTRIC LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
I
RMULTI-ROOM MXZ-8 INVERTER HEAT PUMP
Model Name Outdoor Unit MXZ-BB4BNA Cooling 1 Rated Capacity
Non-ducted Rated Total Input Ducted
Maximum Capacity
Rated CapacityHeating at
Rated Total InputIndoor Unit 4JO F 2 Non-
ductedDucted Maximum Capacity
Rated Capacity Heating at
Rated Total InputlJO F 3 Non-ductedDucted Maximum Capacity
Power Supply Phase Cycle Voltage
Indoor - Outdoor Sl - S2 Voltage
Indoor - Outdoor S2 - S3
MCA
Recommended FuseBreaker Size
Fan Motor
Compressor
Airflow (CoolingHeating)
Refrigerant Control
Outdoor Unit Sound Pressure Level at Cooling 1
Sound Pressure Level at Heating 2
External Finish Color
Dimensions
Weight
Total Capacity 22-130
Indoor Unit ModelQuantity
Remote Controller Type
Type
Refrigerant Charge
Oil
Gas Side OD Refrigerant Pipe
Liquid Side OD
Height Difference (Max)
Maximum Distance between (Outdoor unit and farthest indoor unit)
Refrigerant Pipe Length Maximum Pipe Length -Branch box to Indoor Unit
Total Maximum line length between Branch Box and All Connected Indoor Units
Total Length (Max)
Connection Method IndoorOutdoor
Includes both branch boxes if there are two
Branch Boxes (At least one branch box required)
Btuh
W
Btuh
Btuh
W
Btuh
Btuh
W
Btuh
A
A
Type x Quantity
Motor Output (kW)
Model (Type)
Motor Output (kW)
CFM
dB(A)
dB(A)
W In
D In
H In
Lbs
Btuh
Lbs Oz
Type (fl oz)
In
In
Ft
Ft
Ft
Ft
Ft
4800048000
57806470
54000
5400054000
48205270
60000
3300034700
29503390
3660036550
1 Phase 60Hz 208 230V
AC 208-230V
DC12-24V
32
40
Propeller x 2
0086 + 0086
DC INVERTER-driven Scroll
29
3530
Linear Expansion Valve
54
55
Munsell No 3Y 78 11
37-716
13+1-3 16
53-3 16
278
12000 - 70200
600 - 24000 2-8
Associated with Indoor Unit Model
R410A
18 112
FV50S (73)
58
38
6698 4
230
49
197
377
FlaredFlared
Compatible with the MSZ-A MSZ-FO MSZ-FE MSZ-GE MFZ-KA SEZ-KD PLA and PEAD series indoor units
NOTES Test conditions are based on AHRI 210240 One indoor unit is turned off during low-speed testing under the new test conditions Systems actually exhibit higher energy efficiencies during normal operation
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F (35deg C) WB 75deg F (24deg C)
2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 4]0 F (8deg C) WB 43deg F (6deg C)
3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 17deg F (-8deg C) WB 15deg F(-9deg C)
4 66 applies to installations when the outdoor unit is installed below the indoor unit
Power factor equals 97 percent
Specifications are subject to change without notice
Note Maximum installed capacity is the maximum total of all connected indoor units NOT the maximum capacity produced
Only a single Lineset is needed from the outdoor unit to branch box
See page 25 for MXZ-B information on efficiency
Required Branch Boxes for MXZ-SB4BNA (Maximum of 2 branch boxes can be connected to one outdoor unit requires joint MSDD-50AR-E or MSDD-50BR-E)
s c d N o J ro Vl
0 ro n 3i n OJ d o J U)
PAC-AKA51 BC Branch Box
PAC-AKA31 BC Branch Box LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 23
MSZ WALL-MOUNTED INDOOR UNITS (FOR MXZ-8 OUTDOOR UNITS)
R
(MSZ-GE12NA MODEL SHOWN)
-000 IIIIIII 9000 9000 12000 12000 14000 17200
Heating at 4r Rated Capacity Btuh 7200 10900 10900 14400 13600 18000 21600
F2 Power Supply I Phase Cycle Voltage J -phase 60Hz 208 230V 3
Iindoor Outdoor S1 S2 AC 208 230V
Iindoor Outdoor S2 S3 DC12-24V Voltage
Iindoor Remote vomr Iller Wireless Type (Optional Wired vomroller DC 12V)
IMCA A 10 IFan Motor FLA 076
DRY 162-226shy145-170shy
162-226shy205-272shy 230-275shy
Airflow at Cooling (CFM)
145-170-237-321-399 339-381
237 -321shy381-410
335-420shy 339-420shy(Quiet-Lo-Med-Hishy 399 533 533 Super Hi or Lo-Med-
WET 144-202shy109-134shy
144-202shy170-237shy 194-240shy
Fan Hi-Powerful)1 (CFM)
109-134-201-286-364 307-343
201-286shy350-367
300-385shy 304-385shy364 498 498
Airflow at Heating 145-170shy 145-170shy 145-170shy 205-247shy 230-275shy
(Quiet-Lo-Med-Hi- WET 233-321shy 237-321shy
166-240shy237-321shy
166-240shy304-367shy 339-431shy
Super Hi or Lo-Medshy (CFM) 406 406
367 -381 406
399-420 463 512
Hi-Powerful) 2 Sound Pressure Level at Cooling
19-22-30shy 26-32-38shy 28-33-38shy(Quiet-Lo-Med-Hi-Super Hi or Loshy dB(A) 19-22-30-37 -43 22-31-39-42
37-45 22-33-43-45
44-49 44-49Med-Hi-Powerful) 1
Sound Pressure Level at Heating 19-22-30shy 26-30-35shy 28-33-38shy
(Quiet-Lo-Med-Hi-Super Hi or Loshy dB(A) 19-22-30-37 -43 22-31-40-42 37-43
22-23-43-44 40-46 43-48
Med-Hi-Powerful) 2
I External Finish Color Munsell No 10Y 92 02
IWln 31 middot716
Dimension Unit 10 In 9 18 10-18 9middot18 10-18 9-18
IH In 11-58
I Weight Unit ILbs 22 27 22 27 22 I Field Drainpipe ~D lin 58 Remote Con-
Type Wireless Remote (Optional Wired Controller) troller
ITvpe B41QA Refrigerant ~s$ideOD lin 38 Pipe I Liquid Side 00 In 14
Connection IndoorOutdoor FlaredFlared
Method
1~
II 18000 22500
21600 27600
388-469shy 38$-469shy628-738 628-738
347-420shy 347-420shy562-661 562-661
388-469shy 388-469shy628-738 628-738
34-41-49-53 34-41-49-53
32-41-49-52 32-41-49-52
43-516
9-38
12-1316 37
58 38
MXZ-2B20NA is also compatible with the MSZ-A and MSZ-FD series indoor units NOTES Test conditions are based on AHRI 210240
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F(6deg C) 3 Indoor units receive power from outdoor units through field-supplied wiring
Specifications are subject to change without notice LIMITED WARRANTY Seven-year warranty on compressor Five-year warranty on parts For data on specific indoor unit combinations see page 21
SEZ DUCTED INDOOR UNIT (FOR MXZ-8 OUTDOOR UNITS)
I
Notes 1 Cooling-Indoor DS 80deg F(267deg C) WS 67deg F(194deg C) Outdoor DS 95deg F (35deg C) WS 75deg F(239deg C)
2 Heating-Indoor DS 70deg F(211 deg C) WS 60deg F(156deg C) Outdoor DS 47deg F (83deg C) WS 43deg F(61 deg C)
3 External static pressure is factory set to 006 WGAdjustable via the
1---------t---+-----L-------------1~---__I PAR-21MAA
1--_____----__________+-____---L____----~_____________1 4 Indoor units receive power
jE~~~~-------------r----1-----~-~~~~~~~~-----___1 from outdoor units through fieldsupplied interconnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven-year warranty on compressor Five-year
1---------------------+---+------------------------1 warranty on parts
~--__I_~----------+-------~l----------I For data on specific indoor unit combinations see page 21 - 23
I--~------+~-----------~----------r_------------I
- Reference page 17 for SEZ static performance curves
24 MITSUBISHI ELECTRIC
25-30-35-40 26-31-36-41 35-38-42-46
25-30-35-40 28-31-36-41 35-38-42-47
MFZ FLOORLOW WALL INDOOR UNIT (FOR middotMXZ-8 OUTDOOR UNITS)
------shy
-==
Airflow at Heating (CFM) 177-198-219-332 184-201-219-335 261-275-297-434
Voltage
Fan
Airflow at Cooling (Lo-Med-Hi-Super Hi)1
169-205-251-314 251-279-325-394
163-197-241-303 170-207-252-309 241-269-313-379
(Lo-Med-Hi-Super Hi) 2
SLZ CEILING-RECESSED INDOOR UNIT (FOR MXZ-8 OUTDOOR UNITS) EFFICIENCY RATINGS
Voltage
Fan
Galvanized-steel SheetsMunsell 64Y 89 04
Refrigerant Pipe
Model Indoor Unit Type SEER HSPF
MXZ-2B20NA-1
Non-dueted 18 89
Dueted and Non-dueted 1675 87
Dueted 155 85
MXZ-2B20NA-1 ENERGY STAR amp
TAX CREDIT 2 x MSZ-GE09NA 18 89
MXZ-3B24NA
lJon-dueted 175 93
Dueted and Non-dueted 1625 89
Dueted 150 85
MXZ-3B24NA ENERGY STAR amp
TAX CREDIT
2 x MSZ-GE06NA 1 x MSZ-GE09NA
175 93
MXZ-3B24NA ENERGY STAR amp
TAX CREDIT
2 x MSZ-GE06NA 1 x MSZ-GE12NA
175 93
MXZ-3B30NA
Non-dueted 175 105
Dueted and Non-dueted 16 100
Dueted 145 95
MXZ-4B36NA
Non-dueted 18 93
Dueted and Non-dueted 16 5 92
Dueted 150 9 0
MXZ-BB4BNA
Non-dueted 15 87
Dueted and Non-dueted 14B B8
Dueted 147 89
Connection IndoorOutdoor FlaredFlared
Method
Notes 1 Cooling-Indoor DB 80deg F(267deg C) WB 67deg F(194deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(239deg C) 2 Heating-Indoor DB 70deg F(21 1 deg C) WB 60deg F(156deg C) Outdoor DB 47deg F(83deg C) WB 43deg F(61 deg C) 3 Indoor units receive power from outdoor units through field supplied interconnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 25
Notes 1 Cooling-Indoor DB 80deg F(267deg C) WB 67deg F (194deg C) Outdoor DB 95deg F (35deg C)WB 75deg F (239deg C)
2 Heating-Indoor DB 70deg F(211deg C) WB 60deg F (156deg C) Outdoor DB 47 F (83deg C) WB 43deg F (61 deg C)
3 Indoor units receive power from outdoor units through field supplied interco(lnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven -year warranty on compressor Five-year warranty on parts
Presently there is no 1 1 system with the MFZ indoor unit
s c
N o J ro Vl
C ro n ~ n OJ t o J V)
M-SERIES RATING CONDITIONS
INDOOR INTAKE AIR TEMPERATURE
OUTDOOR INTAKE AIR TEMPERATURE
COOLING
MAXIMUM
95degF DB 71 degF WB (MU SUZ MXZ-2B20-13B243B304B36) 90degF DB 73degF WB (MUZY-GE MUZ-FE MUzy-D)
115degF DB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B24 3B304B368B48)
MINIMUM 67degF DB 57degF WB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B201 3B243B304B36)
14degF DB (MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B24 3B304B36) 23degF DB (MXZ-8B48) 6rF DB (MU)
MAXIMUM 80degF DB 6rF WB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B243B304B36)
75degF DB 65degF WB (MUZY-GE MUZY-GA24 MUZ-FE SUZ MXZ-2B20-1 3B243B304B36) 70degF DB (MXZ-8B48)
HEATING
MINIMUM 70degF DB 60degFWB (MUZ-GE MUZ-GA24 MUZ-D MUZ-FE SUZ MXZ-2B20-1 3B243B304B36)
-13degF DB -15degFWB (MUZ-FE) -4degF DB -5degF WB (SUZ MUZ-GE) 5degF DB 4degF WB (MUZ-GA24 MXZ-8B48NA) 6degF DB 5degF WB (MXZ-2B20-1 3B24 3B304B36) 14degF DB 13degFWB (MUZ-D)
MU units operate at intake air temperature down to 10deg Fwith the addition of an ICM-326HM-1 low temperature control
REFRIGERANT TUBING SETS
OPTIONAL ACCESSORIES
REFRIGERANT LINE LENGTH FLARE FLARE _INDOOR UNIT OUTDOOR UNIT
MS-A09WA MU-A09WA 35 MS-A12WA
65 MU-A12WA 35
MSY-GE09NA 65
MUY-GE09NA 40
MSY-GE12NA
65
MUY-GE12NA 65 40
MSY-GE15NA MUY-GE15NA 40
MSY-GE18NA
65
MUY-GE18NA 100 50
MSZ-GE09NA MUZ-GE09NA 65 40
MSZ-GE12NA MUZ-GE12NA 40
MSZ-GE15NA
65
MUZ-GE15NA 40
MSZ-GE18NA
65
MUZ-GE18NA 100 50
MSY-GE24NA MUY-GE24NA 100 50
MSZ-GE24NA MUZ-GE24NA 100 50
MSY-D30NA MUY-D30NA 100 50
MSZ-D30NA MUZ-D30NA 50
MSY-D36NA
100
MUY-D36NA 50
MSZ-D36NA
100
MUZ-D36NA 100 50
MSZ-FE09NA MUZ-FE09NA 40
MSZ-FE12NA
65
MUZ-FE12NA 40
MSZ-GE06091215NA MSZ-FE0912NA
65
MXZ-2B20NA-1 164 4933MFZ-KA0912NA SEZ-KD09 1215NA
MSZ-GE0609 121518NA MSZ-FE091218N MFZ-KA09 1218NA MXZ-3B24NA 164 4933 SEZ -KD09 12 15 18NA SLZ-KA09 12 15NA
MSZ-GE0609 121518NA MSZ-GA24NA MSZ-FE091218NA
MXZ-3B30NA 4933230MFZ-KA091218NA SEZ -KD09 121518NA SLZ-KA09 12 15NA
MSZ-GE0609121518NA MSZ-GE24NA MSZ-FE09 12 18NA
MXZ-4B36NA 230 4933MFZ-KA091218NA SEZ -KD09121518NA SLZ-KA09 12 15NA
MSZ-GE0609 12 15 18NA MSZ-GE24NA MSZ-FE09 12 18NA
MXZ-8B48NA 6698377MFZ-KA091218NA SEZ-KD09121518NA SLZ-KA09 12 15NA
PART NUMBER I USE WITH I DESCRIPTION
Port Adapters and Connection Pipes MAC-A454JP-E MXZ-Series Adapter 38 X12
MAC-A455JP-E MXZ-Series Adapter 12 X38
MAC-A456JP-E MXZ-Series Adapter 12 X58
MSDD-50AR-E MXZ-Series Branch Box Tee Distribution Pipe - Flare Connection between two branch boxes
MSDD-50BR-E MXZ-Series Branch Box Tee Distribution Pipe - Braze Connection between two branch boxes
PAC-493PI MXZ-Series Adapter 14 X38
PAC-SG76RJ-E MXZ-Series Adapter 38 X58
OPTIONAL ACCESSORIES CONTINUED ON NEXT PAGE
49 amp 66 applies to installations in which the outdoor unit is installed below indoor unit26 MITSUBISHI ELECTRIC
OPTIONAL ACCESSORIES (CONTINUED)
PART NUMBER USE WITH DESCRIPTION Control Options and Accessories
M21 JKO 307 M-Series Indoor Units Remote temperature sensor for M-Series indoor units
MAC-397IF-E
MAC-399IF-E
PAC-YU25HT
PAR-21 MM-G
M-Series INVERTER Units
M-Series INVERTER Units
SEZ-KD Indoor Units
Use with P-Series SEZ and for wired M-Series Controller
MA and contact terminal interface - Required to use PAR-21 MM wired wall mount controller with M-Series Systems
CMCN M-NET control adapter I Interface for Mr Slim M-Series MSYZ SEZ I MFZ
External Fan I Heater control relay adapter
Deluxe MA remote controller (Requires MAC-397IF-E for use with M-Series - MSYZ MFZ)
SEZ Wireless remote controller for SEZ units (Requires signal receiver PAR-SA9FA-E)PAR-FL32MA
PAR-SA9CA-E SEZ Wireless signal receiver for SEZ
3-pole disconnect switch 30A 600V turns off power between indoor and outdoor units shyM-SeriesTAZ-MS303
mounts in 2 X 4 utility box and requires standard single gang switch platecover - Low Ambient
ICM-326HM-2 M-Series Non-INVERTER units Low ambient head pressure controller MUZ-GE091215 IVIUZ-FE0912 SUZ-KD091215
Drain pan heaterMAC-640BH-U outdoor unit
MAC-641 BH-U MUZ-GE18 SUZ-KD18 outdoor unit Drain pan heater Filters
MAC-1415FT-E Anti-allergy enzyme filter
MAC-2300FT
MSZlMSY-D3036
Anti -allergy enzyme filter
MAC-308FT
MSYMSZ-GA24
MSZ-FD912 I FE0912 Platinum deodorizing filter
MAC-408FT-E Anti-allergy enzyme filter
MAC-415FT-E
M-Series Indoor Unit - GE09GE12GE15GE18
MFZ-KA Air Cleaning FilterAnti-Aliergy Enzyme Filter
MAC-418FT Anti-allergy enzyme filter
Filter Boxes
FBL1-1
MSZ- FD912 I FE091 2
FB Series Filter Box for SEZ-KD09NA Optional filter box with MERV 8 filters
FB Series Filter Box for SEZ-KD1215NAFBL1-2 Optional filter box with MERV 8 filters
and PEA-A 12M
FBL1-3 FB Series Filter Box for SEZ-KD18NA Optional filter box with MERV 8 filters
Pumps
SI1730-230 MSYZ - 30000 Btuh or greater Sauermann mini condensation pump 230V
S13100-115 MS-Series - non-INVERTER Sauermann mini condensation pump 115V
S13100-230 Sauermann mini condensation pump 230VMSYZ - Less than 30000 Btuh
Miscellaneous BRP-1 Bottom Return Plate for SEZ-KD09NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-2 Bottom Return Plate for SEZ-KD12KD15-NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-3 Bottom Return Plate for SEZ-KD18NA Converts low profile ducted indoor unit from rear return to bottom return
BV12FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderreglnsulated - 12
BV14FSI Use with any Mr Sl im multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 14
BV38FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 38
BV58FSI Use with any IVIr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 58
Condensing unit wall mounting brackets (set of 2) - 440 lb capacity painted steel NOTE CWMB1 IVIU and PU outdoor units Installer is responsible to select and provide suitable hardware and materials to insure proper
mount of bracket to wall
DSD-400N M-Series DiamondBacktrade Platform Stands MUZ-GE18 I MUZ(y)-03036 I
MAC-811DS Drain socket assemblySUZ-KA18
MAC-851DS MUZ-FD0912 Drain socket
MAC-855SG M-Series Air outlet guide
MAC-856SG M-Series Air outlet guide - MXZ-3B24 I 3B30 I 4B36 NA
MAC-860DS MUZ-GE091215 I MUZ-FE0912 Drain socket
MAC-889SG M-Series Air outlet guide- MXZ-2B20NA
MAC-S99SG M-Series Air outlet guide
PAC-SG59SG-E IVIXZ-SB4SNA Air outlet guide (1 piece) I MXZ-SB48NA (Requires 2 pieces)
PAC-SG61 DS-E MXZ-8B4SNA Drain socket - connector
PAC-SG64DP-E MXZ-SB48NA Drain pan
RCMKP1CB lVI-Series Wireless Lockdown bracket for remote controller
lILTRILlTE1 All M-Series Condensing unit mounting pad 16 x 36 x 3
MITSUBISHI ELECTRIC 27
MXZ-8 Series Port Adapter chart Port Adapter Unit Port
Combinations Required Size
MXZ-2B20NA-1
2-zone combinations wi NA
A 38 x both units s12K 14
1-MAC-A454JP-E B 38 x
6+15 14
9+15 1-MAC-A454JP-E
MXZ-3B24NA
All rated 2-zone combina-NA
A 12 x tions 14
All rated 3-zone combina-NA
B 38 x tions 14
C 38 x 14
MXZ-3B30NA
2-zone combinations wi at NA
A 12 x least one unit s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
9 + 24 14
3-zone combinations wi 1-MAC-A455JP-E
all units s12K
All other rated 3-zone NA
comb
MXZ-4B36NA
2-zone combinations wi at NA
A 12 x least one un it s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
6 + 24 14
1-MAC-A456JP-E D 38 x
9 + 24 14
3-zone combinations wi at NA
least two units s12K
3-zone combinations wi 1-MAC-A454JP-E
two units15K
6+6+24 or 6+9+24 1-MAC-A456JP-E
9+9+24 1-MAC-A456JP-E
4-zone combinations wi at 1-MAC-A455JP-E
least three units s12K
6+6+15+15 1-MAC-A454JP-E
6+6+15+15 1-MAC-A454JP-E
Note When using the Pu-A24BA PCA-A24KA or PEAD-A24AA two port adapter will be needed 1-MAC-A456JP-E (12 x 58) A port or 1-PACshySG76RJ-E (38 x 58) B C and D ports and 1-PAC493PI (14 x 38)
28 JMITSUBISHI ELECTRIC
6+6+246+9+24 6+12+249+9+24 9+12+24 or 12+12+24
6+15+24 6+18+24 9+15+249+18+24 12+15+24 or 12+18+24
15+15+24 15+18+24 or 18+18+24
15+24+24 or 18+24+24
Combinations of 4 or more zones
1-PAC-SG76RJ-E
See notes for application below
2
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
See notes for application below
PORT A =38 gas x 14 liquid
PORT B =38 gas x 14 liquid
PORT C =38 gas x 14 liquid
PORT A =38 gas x 14 liquid
PORT B = 38 gas x 14 liquid
PORT C = 38 gas x 14 liquid
PORT D =38 gas x 14 liquid
PORT E =12 gas x 14 liquid
Notes for application bull Check the lineset sizes for your indoor selected models bull Select the branch box or boxes needed for your application bull Compare indoor unit lineset sizes as compared to branch
box sizes bull Connect 15K + indoor units to the larger port on the
(PAC-AKA51 BC) bull Adapt lineset size with appropriate port adapter from
above list bull When using the PU-A24BA or PEAD-A24AA two port
adapter will be needed 1-MAC-A456JP-E (12 x 58) or 1-PAC-SG76RJ-E (38 x 58) and 1-PAC493PI (14 x 38)
-fv
~ DIAMONDBACKtrade
~) BV-Series Ball Valves Model numbers
BV14FFSI BV38FFSI
LISTED 891N REFRIGERANT
BV12FFSI VALVE bull Engineered for Mini-split andBV58FFSI
Multi-split HVAC Units bull Size available 14 38 12 58
bull Full Port Designbull Fully factory assembled bull Furnace brazed and pressure tested bull 700 PSIG Rated bull Each ball valve is equipped with Schraderreg Valve
for refrigerant service bull R-410A Compatible bull Design working pressure 700 PSIG bull Temperature range bull Flare Connections
-40 0 F to +3250 F (-400 C to + 1490
C) bull Forged brass body and seal cap bull Teflonreg seals and gaskets (no synthetic a-rings) bull Seal cap design permits valve operation without
removal of seal cap bull Suitable for use with R-11 R-22 R-123 R-125
R-134A R-236FA R-4202A R-402B R-404A R-407C R-410A R-500 R-502 and R-507
bull One year limited materials and workmanship
Part Number SAE Flare
A B C 0 E F
BV14FFSI 14 619 260 180 122 142 110
BV38FFSI 38 630 267 180 122 142 110
BV12FFSI 12 651 267 180 122 142 110
BV58FFSI 58 664 267 180 128 142 110
Ball valves come With an insulation piece warranty on Ball Valves
~ DIAMONDBACKtrade
~) Platform Stands
Lift the Mitsubishi Electric Comfort Solution
outdoor unit to new heights with our Diamondback Platform Stands
bull Easy to install
bull Available for all sizes of Mr Slim outdoor units
bull Color matched to the outdoor units
Model Number DSD-400N
L 15-34 x W 3-14 x H 3-14
r
)MITSUBISHI ELECTRIC 29
~ DIAMONDBACKtrade LINESETS
~~
Twin-Tube Lineset Insulation Design
bull Balanced outside diameter for uniform coiluncoil position stability
bull Minimum 12 insulation thickness on both tubes Diamondback Advantages include the following features
bull Quick efficient and economical field installation using factory applied Twin Tube insulation and flare connections with flare nuts mounted
bull Correct lengths for reducing waste and time
bull Quality consistency and economy
bull All Diamondback Lineset tubing is tested in accordance with ASTM E243
Filter Boxes
FB Series filter boxes are available in compatible sizes for all Mr Slim horizontal ducted indoor units
FBL 1 filter boxes include 1 thick pleated MERV 8 filter(s) installed Filters are tested in accordance with ANSIASHRAE Standard 522 and Rated Class 2 under UL Standard 900
The cabinet is constructed of non-insulated 20 gauge G-60 galvanized
FBL1-1 FB Series Filter Box for SEZ-KD09NA
FBL1-2 FB Series Filter Box for SEZ-KD12KD15-NA
FBL1-3 FB Series Filter Box for SEZ-KD18NA
steel with foam gasket and provides an air-tight connection to indoor unit and access door Gasket material complies with UL 723 requirements
A screw-through cabinet design for secure attachment to indoor unit and return connection in rear is easily field-converted to bottom return
30 MITSUBISHI ELECTRIC
bull
bull
bull
bull
bull
bull
LINE-HIDE~ Put a professional finish on air-conditioning
installations with an easy-to-install modular
system that beautifies exteriors and
protects Linesets drainlines and wiring
Can be use it indoors too Meets UL94v-O for interior applications
Has snap-on covers and a full selection of couplings elbows T-joints caps and more for any application complex or simple
Offers high-quality PVC with UV inhibitors for outdoor service in all weather conditions
Can be painted with most house paints to match exterior decors
Is not just for HVAC Hide any exterior cabling piping or wiring
Available in four sizes 2-14 3 4 and 6 tubes
Download a brochure at wwwline-hidecom to find out more information
For more information on our CITY MULTI VRF product line visit our website at wwwmitsubishiprocom
_lIJrUlllln ~ ~IIII1 fInll l
~
l bull bull
JMITSUBISHI ELECTRIC 31
MHK1 WIRELESS REMOTE CONTROLLER KIT Exclusive for INVERTER-driven Mr Slimreg Systems VlWireless Technology a J
JMITSUBISHI ELECTRIC
Wireless Receiver
MHK1 Kit includes
09 mMRCH1 WIRELESS REMOTE CONTROLLER I Nbull Backlit easy-to-read display o
bull Dual setpoint control with system changeover J m
bull Enabled with RedLlNKTM reliability
bull Compatible with MCCH1 Vl Portable Central Controller m
N bull Installs Anywhere Vl
MFH1 WIRELESS RECEIVER N Vlbull Required for MRCH1 Wireless
CRemote Controller m bull Enabled with RedLiNK reliability n
31 n OJ o J en
SEZ and SLZ 11 systems with SUZ outdoor unit
Function Description
ONOFF OnOff operation for a single indoor unit
Operation Mode Cool I Drying I Auto I Heat I Fan only Available operation modes dependant on connected system
Temperature Setting Set temperature from 50degF - 8rF depending on operation mode and connected system
System Changeover Deadband Value 2-8degF
Schedule Operation 5-25-1-1
Fan Speed Setting HiMid-2Mid-1 IlowlAuto Available fan speed settings dependant on connected system
Air Flow Direction Setting Air flow angles 100deg - 80deg - 60deg - 40deg and oscilate Available air flow direction settings dependant on connected system
PermitProhibit Function Individual prohibit operations for each remote controller function (ONI OFF Set Temperature and Operation Mode)
Space Temperature Displays the measured space temperature
Error Indication Displays error code
Display Outside Temperature and Humidity
Requires optional MOS1 Outside Air Sensor
Dimensions - ryv x D x H) Remote Controller 5-316 x 1-12 x 3-916 Receiver 3-14 x 1-516 x 6-716
Operating Ambient Temperature Remote Controller 32 - 120degF Receiver -40 - 165degF
Operating Ambient Humidity Remote Controller 5 - 90 RH (non-condensing) Receiver 5 - 90 RH (non-condensing)
Power Supply 2 AA batteries
MRCH1 MIFH1 MRC1
Wireless Wall-Mounted Remote Controllers Wireless Receiver Cable
Accessories MCCH1 MOS1
Portable Central Controllers Outside Air Sensor
MITSUBISHI ELECTRIC 17
MULTIPLE ROOMS WITH INDIVIDUAL CONTROL FROM A SINGLE SYSTEM Enjoy ideal levels of comfort in the rooms you use most with our multi-room system Each room (zone) operates independently People in different rooms - the kitchen master bedroom or living room - can enjoy temperature settings that make each of them most comfortable
If you re looking for a complete comfort solution for several different rooms the MXZ multi-room system is the right choice The system is flexible enough to conform to a particular cooling and heating need and offers numerous different indoor unit combinations In addition up to eight indoor units can be connected to one outdoor unit Now with a SEZ horizontal ducted unit and a MFZ floorshystanding unit homeowners can enjoy an even greater range of zoning options provided by an MXZ system
An MXZ multi-room system is an excellent choice for supplementing capacity to a current system conditioning newly furnished spaces or new additions and replacing a system within a home Homeowners can also benefit from lower energy costs year-round while staying comfortable thanks to Mitsubishi Electrics energy-efficient technologies that are a part of every system that we make
To add to the level of energy efficiency the MXZ -2B20NA and MXZ -3B24NA systems qualify for both ENERGY STARreg and the federal tax credit (See details on page 21 for applicable indoor unit combinations)
At right a single level home with several system types represented (For illustrative purposes only)
MFZ Floor-Standing Indoor Units for MXZ Heat Pump Systems
Floor-standing indoor unit mounts three inches above the floor and has front panel access to the filter for ease of cleaning
The MFZ units provide energy-efficient solutions to provide personalized comfort for difficult areas that may be smaller or dont have usable space on the walls
MFZ units on MXZ systems include the following features bull Top and bottom discharge vanes bull Hot-start technology bull Quiet operation bull Wireless remote control (optional wall-mounted controller)
18 MITSUBISHI ELECTRIC
MSZ Wall-Mounted Indoor Units for MXZ Heat Pump Systems
Providing a wide range of cooling and heating capacities each wall-mounted indoor unit mounts high on a wall and connects to a branch box or the outdoor unit by a refrigerant line run via a 3 hole The MSZ units provide highly efficient solutions to cooling and heating needs and provide personalized comfort for the individual zones in which they are installed
MSZ units on MXZ systems include the following features bull Sleek flat panel design bull Hot-start technology bull Quiet operation bull i-seeM sensor technology (MSZ-FE0912NA models only) bull Enhanced filtration system (MSZ-FE0912NA models only) bull Wireless remote control (optional wired wall-mounted controller)
SLZ Ceiling-Recessed Indoor Units for MXZ Heat Pump Systems
The new SLZ-KA ceiling casette systems offer a wide air-flow pattern for better air distribution
offered to your customers Installation can be done in a hard ceiling (with a access panel for servicing) or placed into a 2x2 drop ceiling With a built-in drain lift mechanism for condensate
removal and a 4 ventilation air intake knockout option the SLZ is ready to handle a variety of installation needs
SLZ units on MXZ systems include the following features bull Wide air-flow pattern for better air distibution bull 4 ventillation air intake knockout bull Built-in condensate lift mechanism bull Wireless RedLlNKTM remote controller
SEZ Horizontal Ducted Indoor Units for MXZ Heat Pump Systems
SEZ ducted units can provide split air-conditioning system advantages with the added benefit of being concealed to provide virtually no visual footprint within the conditioned space other than a register and grille for the air to flow With the use of short run ductwork these units can provide comfort to a single room that needs air dispersed evenly throughout the space unusually shaped rooms and adjacent rooms
The SEZ unit on MXZ systems include the fOllvowin fatures _
g~e~~~~==Zl[bull Concealed design for short-run ductwork bull Quiet operation bull Built-in condensate lift mechanism
JMITSUBISHI ELECTRIC 19
s c t
I
N o J ro o ltro ~ ro ~
DIAMOND COMFORT MXZ MULTI-ZONE SYSTEMS MXZ-B Series multi-zone systems provide personalized comfort control and energy efficiency in up to eight rooms with only a single outdoor unit The MXZ-B Series system features include
bull Individual zone control bull Mix and match flexibility of indoor unit styles and combinations bull A wide range of indoor unit capacities that match the room size and requirements bull Flexible design options to tackle the most challenging multi-room installations bull Efficient systems including three systems [mxz series] that meet energy starltID and
federal tax credit requirements bull Simple quick and cost-effective installation keeps install costs down on new construction
and disruption to a minimum on renovations and refits
Efficiency and performance ratings depend on the number style and capacity of the indoor units installed with each Multi-Zone System
MXZ -2 B20 NA - 1 (2 1 ) MXZ -3 B24 NA (2 13 1) Ou tdoo r Unit Outdoor Uni t
MSZ-GE09NA Indoor Units
SEZ-KD12NA Indoor Unit
MSZ- GE06NA
~~~~li
(At least two indoor units MSZ-GE06NAIndoor Unit must be installed) Indoor Unit
(Two indoor units must be installed )
MXZ -3 B30 NA (2 1 3 1) Outdoor Unit
SEZ-KD12NA Indoor Unit
~~~i
(At least two indoor units MSZ-GE06NA must be installed)
Indoor Unit ~
MFZ- KD12NA Indoor Unit
MXZ-8B48NA (2 1-8 1) Outdoor Unit
(At least two indoor units
must be installed)
(At least two indoor units must be installed)
MFZ-KD09NA Indoor Units
MSZ-GE09NA Indoor Units
SEZ-KD12NA Indoor Unit
MSZ INDOOR UNIT
MSZ-FE18NA
PEAD HORIZONTAL -DUCTED INDOOR UNIT
PEAD-A24AA
MSZ INDOOR UNIT SEZ HORIZONTAL-DUCTED MSZ-FE18NA
INDOOR UNIT MFZ FLOOR-STANDING SEZ-KD18NA INDOOR UNIT
MFZ-KA12NA
20 AMITSUBISHI ELECTRIC
MULTI-ROOM MXZ-8 INVERTER HEAT PUMP R
Model Name Outdoor Unit MXZ-2B20NA-1 5 MXZ-3B24NA 6 MXZ-3B30NA MXZ-4B36NA 7
Indoor Unit
Cooling 1 Non-ductedl Ducted
Rated Capacity Btuh 1800020000 2200023600 28400127400 3540034400
Capacity Range Btuh 7800-20000 12600-25500 12600-28400 12600-36400
Total Input W 2190 (630-219QL 2460 (1000-2950) 3330 l1 000-3330) 3 940 (1 000-4020)
Heating at 4JO F 2 Non-ductedl Ducted
Rated Capacity Btuh 2200022000 2500024600 2860027600 3600034400
Capacity Range Btuh 8500-25500 11400-30600 11 400-36000 11400-43000
Total Input W 2620 (520-2620) 1900 (740-2600) 2220 (740-2820) 3100 (740-3940)
Heating at 1JO F 3 Non-ductedl Ducted
Rated Capacity Btuh 1250012500 1400014000 1600015100 2220020300
Rated Total Input W 13501430 13801570 21202 140 24302340
Maximum Capacity Btu h 1450014500 1880017000 1880018000 2460025400
Maximum Total Inl2ut W 15001590 21202230 21202140 33403450
Power Supply Phase Cycle Voltage 1-phase 60Hz 2081 230V 8
Voltage Indoor shy Outdoor S1 - S2 AC 2081 230V
Indoor shy Outdoor S2 - S3 DC12-24V
Outdoor Unit 4
MCA A 15 19
MOCP A 20
Fan Motor FLA 096 093
Compressor
Model (Type)
DC INVERTER-driven Twin Rotary
RLA 101 11 144
LRA 15
Airflow (CoolingHeating) CFM 14851 640 20681605 13651605 20682068
Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1
dB(A) 49 54 49 54
Sound Pressure Level at Heating 2
dB(A) 51 49 57
External Finish Color Munsell No 30Y 781 1
Dimensions
W In 33-116 35-716
D In 13 12-58
H In 27-1516 35-7116
Weight Lbs 130 150 153
Indoor Unit No of Units 2 23 23 234
Remote Controller Type Associated with the Indoor Unit
Refrigerant
Type R410A
Charge Lbs Oz 515 7 11 813
Oil Type (fl oz)
NE022 (237) NE022 (294)
Refrigerant Pipe Gas Side 00 In AB 38 A 12 BC 38 A 12 BCD 38
Liquid Side 00 In 14
Refrigerant Pipe Length Height Difference (Max) Ft 4933 9
Length (Max) Ft 164 (A+B) 230 (A+B+C) 230 (A+B+C+D)
Connection Method IndoorOutdoor FlaredlFlared
Compatible with the MSZ-A MSZ-GA MSZ-FD MSZ-FE MSZ-GE MFZ-KA and SEZ-KD series indoor units (PLA-18 amp PCA-24 on the MXZ-MXZ-3B PLA-24 amp PCA-24 on the MXZ-4B)
NOTES Test conditions are based on AHRI 210240 One indoor unit is turned off during low-speed testing under the new test conditions Systems actually exhibit higher energy efficiencies during normal operation
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F (35deg C) WB 75deg F (24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F (6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 600 F (160 C) Outdoor DB 17deg F (_80 C) WB 150 F (_90 C) 4 Refer to pages 12 and 13 for Indoor Unit specifications 5 Data from combination of two Indoor Units 9000 Btuh (non-ducted) or one 9000 Btuh and one 12000 Btuh (ducted) 6 Data from combination of two Indoor Units 6000 Btuh and one 9000 Btuh (non-ducted) or three 9000 Btuh (ducted) 7 Data from combination of four Indoor Units 9000 Btuh (non-ducted and ducted) 8 Indoor units receive power from outdoor units through field-supplied interconnected wiring 9 49 Applies to installations where the outdoor unit is installed below the indoor unit
Power factor equals 97 percent
Specifications are subject to change without notice
MULTI-ZONE ENERGY STAR AND TAX CREDIT SYSTEMS
Model Indoor Unit Combinations SEER HSPF
MXZ-2B20NA-1 2 x MSZ- GE09NA 18 8 9
MXZ- 3B24NA 2 x MSZ- GE06NA 1 x MSZshy GE09NA
17 5 9 3
MXZ- 3B24NA 2 x MSZ-GE06NA 1 x MSZ- GE12NA
17 5 93
For more details on all ENERGY STAR and tax credit systems go to wwwmitsubishicomfortcomtaxcredit
See page 25 for additional info on efficiency
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 21
MXZ-8B48NA THE ULTIMATE ZONING SOLUTION
The Mitsubishi Electric MXZ-S84SNA eight-zone unit As a member of the expanding MXZ-B Series of multi-zone systems the MXZ-8B outdoor unit incorporates branch boxes to connect up to eight indoor units MXZ- 8 B48 NA (2 1 - 8 1 )
Outd oor Uni t The INVERTER-driven compressor at the heart of the MXZ-8B -~-- shy
outdoor unit provides variable capacity control allowing the system to adjust to the specific demands of the interior space ~ as needed not the hard start and stop of a traditional system I[iDA Jinstalled in most US homes
The MXZ -8B48NA has only one port on the outdoor unit for two insulated refrigerant lines which run into the home or business to connect to a branch box or boxes From the branch box(es) gas and liquid refrigerant piping run to each of the indoor units The LEV in the branch box(es) controls the refrigerant flow as the load of each zone changes
Through the branch box(es) (the PAC-AKA31 BC three-port andor the PAC-AKA51 BC five-port) the system can connect from two indoor units up to eight indoor units depending on application requirements
The flexibility of the system doesnt stop there The MXZ-8B48NA has rated capacities of 48000 Btuh for cooling and 54000 Btuh for heating System operation however can range from a minimum 12000 Btuh to a maximum 54000 Btuh in cooling and a maximum of 60000 Btuh in heating This type of performance supports a large variety of applications
The MXZ-8B48NA allows for further flexibility because it supports a connected indoor unit capacity from 22 to 130 or 12000 Btuh to a maximum 70200 Btuh depending on diversity
Connectable Indoor Units General Features bull Four-ton outdoor unit can support up to
eight indoor units using branch boxes bull Wide variety of indoor unit styles
-=--_-=-----= - - J _ 1
including wall-mounted floor-standing MSZ-FE09 12 18NA MSZ-GE06 09 12 15 18 24NA ceiling-cassette ducted
bull Individual control up to eight (8) zones using wired or wireless controls
bull Advanced microprocessor control bull Auto restart following a power outage bull Self-check function offering SEZ-KD09 1215 18NA PEAD-A24AA
integrated diagnostics ~--- Jbull Limited warranty five years on parts and
defects and seven years on compressors
SLZ-KA09 1215NA MFZ-KA09 12 18NA
22 MITSUBISHI ELECTRIC LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
I
RMULTI-ROOM MXZ-8 INVERTER HEAT PUMP
Model Name Outdoor Unit MXZ-BB4BNA Cooling 1 Rated Capacity
Non-ducted Rated Total Input Ducted
Maximum Capacity
Rated CapacityHeating at
Rated Total InputIndoor Unit 4JO F 2 Non-
ductedDucted Maximum Capacity
Rated Capacity Heating at
Rated Total InputlJO F 3 Non-ductedDucted Maximum Capacity
Power Supply Phase Cycle Voltage
Indoor - Outdoor Sl - S2 Voltage
Indoor - Outdoor S2 - S3
MCA
Recommended FuseBreaker Size
Fan Motor
Compressor
Airflow (CoolingHeating)
Refrigerant Control
Outdoor Unit Sound Pressure Level at Cooling 1
Sound Pressure Level at Heating 2
External Finish Color
Dimensions
Weight
Total Capacity 22-130
Indoor Unit ModelQuantity
Remote Controller Type
Type
Refrigerant Charge
Oil
Gas Side OD Refrigerant Pipe
Liquid Side OD
Height Difference (Max)
Maximum Distance between (Outdoor unit and farthest indoor unit)
Refrigerant Pipe Length Maximum Pipe Length -Branch box to Indoor Unit
Total Maximum line length between Branch Box and All Connected Indoor Units
Total Length (Max)
Connection Method IndoorOutdoor
Includes both branch boxes if there are two
Branch Boxes (At least one branch box required)
Btuh
W
Btuh
Btuh
W
Btuh
Btuh
W
Btuh
A
A
Type x Quantity
Motor Output (kW)
Model (Type)
Motor Output (kW)
CFM
dB(A)
dB(A)
W In
D In
H In
Lbs
Btuh
Lbs Oz
Type (fl oz)
In
In
Ft
Ft
Ft
Ft
Ft
4800048000
57806470
54000
5400054000
48205270
60000
3300034700
29503390
3660036550
1 Phase 60Hz 208 230V
AC 208-230V
DC12-24V
32
40
Propeller x 2
0086 + 0086
DC INVERTER-driven Scroll
29
3530
Linear Expansion Valve
54
55
Munsell No 3Y 78 11
37-716
13+1-3 16
53-3 16
278
12000 - 70200
600 - 24000 2-8
Associated with Indoor Unit Model
R410A
18 112
FV50S (73)
58
38
6698 4
230
49
197
377
FlaredFlared
Compatible with the MSZ-A MSZ-FO MSZ-FE MSZ-GE MFZ-KA SEZ-KD PLA and PEAD series indoor units
NOTES Test conditions are based on AHRI 210240 One indoor unit is turned off during low-speed testing under the new test conditions Systems actually exhibit higher energy efficiencies during normal operation
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F (35deg C) WB 75deg F (24deg C)
2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 4]0 F (8deg C) WB 43deg F (6deg C)
3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 17deg F (-8deg C) WB 15deg F(-9deg C)
4 66 applies to installations when the outdoor unit is installed below the indoor unit
Power factor equals 97 percent
Specifications are subject to change without notice
Note Maximum installed capacity is the maximum total of all connected indoor units NOT the maximum capacity produced
Only a single Lineset is needed from the outdoor unit to branch box
See page 25 for MXZ-B information on efficiency
Required Branch Boxes for MXZ-SB4BNA (Maximum of 2 branch boxes can be connected to one outdoor unit requires joint MSDD-50AR-E or MSDD-50BR-E)
s c d N o J ro Vl
0 ro n 3i n OJ d o J U)
PAC-AKA51 BC Branch Box
PAC-AKA31 BC Branch Box LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 23
MSZ WALL-MOUNTED INDOOR UNITS (FOR MXZ-8 OUTDOOR UNITS)
R
(MSZ-GE12NA MODEL SHOWN)
-000 IIIIIII 9000 9000 12000 12000 14000 17200
Heating at 4r Rated Capacity Btuh 7200 10900 10900 14400 13600 18000 21600
F2 Power Supply I Phase Cycle Voltage J -phase 60Hz 208 230V 3
Iindoor Outdoor S1 S2 AC 208 230V
Iindoor Outdoor S2 S3 DC12-24V Voltage
Iindoor Remote vomr Iller Wireless Type (Optional Wired vomroller DC 12V)
IMCA A 10 IFan Motor FLA 076
DRY 162-226shy145-170shy
162-226shy205-272shy 230-275shy
Airflow at Cooling (CFM)
145-170-237-321-399 339-381
237 -321shy381-410
335-420shy 339-420shy(Quiet-Lo-Med-Hishy 399 533 533 Super Hi or Lo-Med-
WET 144-202shy109-134shy
144-202shy170-237shy 194-240shy
Fan Hi-Powerful)1 (CFM)
109-134-201-286-364 307-343
201-286shy350-367
300-385shy 304-385shy364 498 498
Airflow at Heating 145-170shy 145-170shy 145-170shy 205-247shy 230-275shy
(Quiet-Lo-Med-Hi- WET 233-321shy 237-321shy
166-240shy237-321shy
166-240shy304-367shy 339-431shy
Super Hi or Lo-Medshy (CFM) 406 406
367 -381 406
399-420 463 512
Hi-Powerful) 2 Sound Pressure Level at Cooling
19-22-30shy 26-32-38shy 28-33-38shy(Quiet-Lo-Med-Hi-Super Hi or Loshy dB(A) 19-22-30-37 -43 22-31-39-42
37-45 22-33-43-45
44-49 44-49Med-Hi-Powerful) 1
Sound Pressure Level at Heating 19-22-30shy 26-30-35shy 28-33-38shy
(Quiet-Lo-Med-Hi-Super Hi or Loshy dB(A) 19-22-30-37 -43 22-31-40-42 37-43
22-23-43-44 40-46 43-48
Med-Hi-Powerful) 2
I External Finish Color Munsell No 10Y 92 02
IWln 31 middot716
Dimension Unit 10 In 9 18 10-18 9middot18 10-18 9-18
IH In 11-58
I Weight Unit ILbs 22 27 22 27 22 I Field Drainpipe ~D lin 58 Remote Con-
Type Wireless Remote (Optional Wired Controller) troller
ITvpe B41QA Refrigerant ~s$ideOD lin 38 Pipe I Liquid Side 00 In 14
Connection IndoorOutdoor FlaredFlared
Method
1~
II 18000 22500
21600 27600
388-469shy 38$-469shy628-738 628-738
347-420shy 347-420shy562-661 562-661
388-469shy 388-469shy628-738 628-738
34-41-49-53 34-41-49-53
32-41-49-52 32-41-49-52
43-516
9-38
12-1316 37
58 38
MXZ-2B20NA is also compatible with the MSZ-A and MSZ-FD series indoor units NOTES Test conditions are based on AHRI 210240
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F(6deg C) 3 Indoor units receive power from outdoor units through field-supplied wiring
Specifications are subject to change without notice LIMITED WARRANTY Seven-year warranty on compressor Five-year warranty on parts For data on specific indoor unit combinations see page 21
SEZ DUCTED INDOOR UNIT (FOR MXZ-8 OUTDOOR UNITS)
I
Notes 1 Cooling-Indoor DS 80deg F(267deg C) WS 67deg F(194deg C) Outdoor DS 95deg F (35deg C) WS 75deg F(239deg C)
2 Heating-Indoor DS 70deg F(211 deg C) WS 60deg F(156deg C) Outdoor DS 47deg F (83deg C) WS 43deg F(61 deg C)
3 External static pressure is factory set to 006 WGAdjustable via the
1---------t---+-----L-------------1~---__I PAR-21MAA
1--_____----__________+-____---L____----~_____________1 4 Indoor units receive power
jE~~~~-------------r----1-----~-~~~~~~~~-----___1 from outdoor units through fieldsupplied interconnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven-year warranty on compressor Five-year
1---------------------+---+------------------------1 warranty on parts
~--__I_~----------+-------~l----------I For data on specific indoor unit combinations see page 21 - 23
I--~------+~-----------~----------r_------------I
- Reference page 17 for SEZ static performance curves
24 MITSUBISHI ELECTRIC
25-30-35-40 26-31-36-41 35-38-42-46
25-30-35-40 28-31-36-41 35-38-42-47
MFZ FLOORLOW WALL INDOOR UNIT (FOR middotMXZ-8 OUTDOOR UNITS)
------shy
-==
Airflow at Heating (CFM) 177-198-219-332 184-201-219-335 261-275-297-434
Voltage
Fan
Airflow at Cooling (Lo-Med-Hi-Super Hi)1
169-205-251-314 251-279-325-394
163-197-241-303 170-207-252-309 241-269-313-379
(Lo-Med-Hi-Super Hi) 2
SLZ CEILING-RECESSED INDOOR UNIT (FOR MXZ-8 OUTDOOR UNITS) EFFICIENCY RATINGS
Voltage
Fan
Galvanized-steel SheetsMunsell 64Y 89 04
Refrigerant Pipe
Model Indoor Unit Type SEER HSPF
MXZ-2B20NA-1
Non-dueted 18 89
Dueted and Non-dueted 1675 87
Dueted 155 85
MXZ-2B20NA-1 ENERGY STAR amp
TAX CREDIT 2 x MSZ-GE09NA 18 89
MXZ-3B24NA
lJon-dueted 175 93
Dueted and Non-dueted 1625 89
Dueted 150 85
MXZ-3B24NA ENERGY STAR amp
TAX CREDIT
2 x MSZ-GE06NA 1 x MSZ-GE09NA
175 93
MXZ-3B24NA ENERGY STAR amp
TAX CREDIT
2 x MSZ-GE06NA 1 x MSZ-GE12NA
175 93
MXZ-3B30NA
Non-dueted 175 105
Dueted and Non-dueted 16 100
Dueted 145 95
MXZ-4B36NA
Non-dueted 18 93
Dueted and Non-dueted 16 5 92
Dueted 150 9 0
MXZ-BB4BNA
Non-dueted 15 87
Dueted and Non-dueted 14B B8
Dueted 147 89
Connection IndoorOutdoor FlaredFlared
Method
Notes 1 Cooling-Indoor DB 80deg F(267deg C) WB 67deg F(194deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(239deg C) 2 Heating-Indoor DB 70deg F(21 1 deg C) WB 60deg F(156deg C) Outdoor DB 47deg F(83deg C) WB 43deg F(61 deg C) 3 Indoor units receive power from outdoor units through field supplied interconnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 25
Notes 1 Cooling-Indoor DB 80deg F(267deg C) WB 67deg F (194deg C) Outdoor DB 95deg F (35deg C)WB 75deg F (239deg C)
2 Heating-Indoor DB 70deg F(211deg C) WB 60deg F (156deg C) Outdoor DB 47 F (83deg C) WB 43deg F (61 deg C)
3 Indoor units receive power from outdoor units through field supplied interco(lnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven -year warranty on compressor Five-year warranty on parts
Presently there is no 1 1 system with the MFZ indoor unit
s c
N o J ro Vl
C ro n ~ n OJ t o J V)
M-SERIES RATING CONDITIONS
INDOOR INTAKE AIR TEMPERATURE
OUTDOOR INTAKE AIR TEMPERATURE
COOLING
MAXIMUM
95degF DB 71 degF WB (MU SUZ MXZ-2B20-13B243B304B36) 90degF DB 73degF WB (MUZY-GE MUZ-FE MUzy-D)
115degF DB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B24 3B304B368B48)
MINIMUM 67degF DB 57degF WB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B201 3B243B304B36)
14degF DB (MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B24 3B304B36) 23degF DB (MXZ-8B48) 6rF DB (MU)
MAXIMUM 80degF DB 6rF WB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B243B304B36)
75degF DB 65degF WB (MUZY-GE MUZY-GA24 MUZ-FE SUZ MXZ-2B20-1 3B243B304B36) 70degF DB (MXZ-8B48)
HEATING
MINIMUM 70degF DB 60degFWB (MUZ-GE MUZ-GA24 MUZ-D MUZ-FE SUZ MXZ-2B20-1 3B243B304B36)
-13degF DB -15degFWB (MUZ-FE) -4degF DB -5degF WB (SUZ MUZ-GE) 5degF DB 4degF WB (MUZ-GA24 MXZ-8B48NA) 6degF DB 5degF WB (MXZ-2B20-1 3B24 3B304B36) 14degF DB 13degFWB (MUZ-D)
MU units operate at intake air temperature down to 10deg Fwith the addition of an ICM-326HM-1 low temperature control
REFRIGERANT TUBING SETS
OPTIONAL ACCESSORIES
REFRIGERANT LINE LENGTH FLARE FLARE _INDOOR UNIT OUTDOOR UNIT
MS-A09WA MU-A09WA 35 MS-A12WA
65 MU-A12WA 35
MSY-GE09NA 65
MUY-GE09NA 40
MSY-GE12NA
65
MUY-GE12NA 65 40
MSY-GE15NA MUY-GE15NA 40
MSY-GE18NA
65
MUY-GE18NA 100 50
MSZ-GE09NA MUZ-GE09NA 65 40
MSZ-GE12NA MUZ-GE12NA 40
MSZ-GE15NA
65
MUZ-GE15NA 40
MSZ-GE18NA
65
MUZ-GE18NA 100 50
MSY-GE24NA MUY-GE24NA 100 50
MSZ-GE24NA MUZ-GE24NA 100 50
MSY-D30NA MUY-D30NA 100 50
MSZ-D30NA MUZ-D30NA 50
MSY-D36NA
100
MUY-D36NA 50
MSZ-D36NA
100
MUZ-D36NA 100 50
MSZ-FE09NA MUZ-FE09NA 40
MSZ-FE12NA
65
MUZ-FE12NA 40
MSZ-GE06091215NA MSZ-FE0912NA
65
MXZ-2B20NA-1 164 4933MFZ-KA0912NA SEZ-KD09 1215NA
MSZ-GE0609 121518NA MSZ-FE091218N MFZ-KA09 1218NA MXZ-3B24NA 164 4933 SEZ -KD09 12 15 18NA SLZ-KA09 12 15NA
MSZ-GE0609 121518NA MSZ-GA24NA MSZ-FE091218NA
MXZ-3B30NA 4933230MFZ-KA091218NA SEZ -KD09 121518NA SLZ-KA09 12 15NA
MSZ-GE0609121518NA MSZ-GE24NA MSZ-FE09 12 18NA
MXZ-4B36NA 230 4933MFZ-KA091218NA SEZ -KD09121518NA SLZ-KA09 12 15NA
MSZ-GE0609 12 15 18NA MSZ-GE24NA MSZ-FE09 12 18NA
MXZ-8B48NA 6698377MFZ-KA091218NA SEZ-KD09121518NA SLZ-KA09 12 15NA
PART NUMBER I USE WITH I DESCRIPTION
Port Adapters and Connection Pipes MAC-A454JP-E MXZ-Series Adapter 38 X12
MAC-A455JP-E MXZ-Series Adapter 12 X38
MAC-A456JP-E MXZ-Series Adapter 12 X58
MSDD-50AR-E MXZ-Series Branch Box Tee Distribution Pipe - Flare Connection between two branch boxes
MSDD-50BR-E MXZ-Series Branch Box Tee Distribution Pipe - Braze Connection between two branch boxes
PAC-493PI MXZ-Series Adapter 14 X38
PAC-SG76RJ-E MXZ-Series Adapter 38 X58
OPTIONAL ACCESSORIES CONTINUED ON NEXT PAGE
49 amp 66 applies to installations in which the outdoor unit is installed below indoor unit26 MITSUBISHI ELECTRIC
OPTIONAL ACCESSORIES (CONTINUED)
PART NUMBER USE WITH DESCRIPTION Control Options and Accessories
M21 JKO 307 M-Series Indoor Units Remote temperature sensor for M-Series indoor units
MAC-397IF-E
MAC-399IF-E
PAC-YU25HT
PAR-21 MM-G
M-Series INVERTER Units
M-Series INVERTER Units
SEZ-KD Indoor Units
Use with P-Series SEZ and for wired M-Series Controller
MA and contact terminal interface - Required to use PAR-21 MM wired wall mount controller with M-Series Systems
CMCN M-NET control adapter I Interface for Mr Slim M-Series MSYZ SEZ I MFZ
External Fan I Heater control relay adapter
Deluxe MA remote controller (Requires MAC-397IF-E for use with M-Series - MSYZ MFZ)
SEZ Wireless remote controller for SEZ units (Requires signal receiver PAR-SA9FA-E)PAR-FL32MA
PAR-SA9CA-E SEZ Wireless signal receiver for SEZ
3-pole disconnect switch 30A 600V turns off power between indoor and outdoor units shyM-SeriesTAZ-MS303
mounts in 2 X 4 utility box and requires standard single gang switch platecover - Low Ambient
ICM-326HM-2 M-Series Non-INVERTER units Low ambient head pressure controller MUZ-GE091215 IVIUZ-FE0912 SUZ-KD091215
Drain pan heaterMAC-640BH-U outdoor unit
MAC-641 BH-U MUZ-GE18 SUZ-KD18 outdoor unit Drain pan heater Filters
MAC-1415FT-E Anti-allergy enzyme filter
MAC-2300FT
MSZlMSY-D3036
Anti -allergy enzyme filter
MAC-308FT
MSYMSZ-GA24
MSZ-FD912 I FE0912 Platinum deodorizing filter
MAC-408FT-E Anti-allergy enzyme filter
MAC-415FT-E
M-Series Indoor Unit - GE09GE12GE15GE18
MFZ-KA Air Cleaning FilterAnti-Aliergy Enzyme Filter
MAC-418FT Anti-allergy enzyme filter
Filter Boxes
FBL1-1
MSZ- FD912 I FE091 2
FB Series Filter Box for SEZ-KD09NA Optional filter box with MERV 8 filters
FB Series Filter Box for SEZ-KD1215NAFBL1-2 Optional filter box with MERV 8 filters
and PEA-A 12M
FBL1-3 FB Series Filter Box for SEZ-KD18NA Optional filter box with MERV 8 filters
Pumps
SI1730-230 MSYZ - 30000 Btuh or greater Sauermann mini condensation pump 230V
S13100-115 MS-Series - non-INVERTER Sauermann mini condensation pump 115V
S13100-230 Sauermann mini condensation pump 230VMSYZ - Less than 30000 Btuh
Miscellaneous BRP-1 Bottom Return Plate for SEZ-KD09NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-2 Bottom Return Plate for SEZ-KD12KD15-NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-3 Bottom Return Plate for SEZ-KD18NA Converts low profile ducted indoor unit from rear return to bottom return
BV12FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderreglnsulated - 12
BV14FSI Use with any Mr Sl im multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 14
BV38FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 38
BV58FSI Use with any IVIr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 58
Condensing unit wall mounting brackets (set of 2) - 440 lb capacity painted steel NOTE CWMB1 IVIU and PU outdoor units Installer is responsible to select and provide suitable hardware and materials to insure proper
mount of bracket to wall
DSD-400N M-Series DiamondBacktrade Platform Stands MUZ-GE18 I MUZ(y)-03036 I
MAC-811DS Drain socket assemblySUZ-KA18
MAC-851DS MUZ-FD0912 Drain socket
MAC-855SG M-Series Air outlet guide
MAC-856SG M-Series Air outlet guide - MXZ-3B24 I 3B30 I 4B36 NA
MAC-860DS MUZ-GE091215 I MUZ-FE0912 Drain socket
MAC-889SG M-Series Air outlet guide- MXZ-2B20NA
MAC-S99SG M-Series Air outlet guide
PAC-SG59SG-E IVIXZ-SB4SNA Air outlet guide (1 piece) I MXZ-SB48NA (Requires 2 pieces)
PAC-SG61 DS-E MXZ-8B4SNA Drain socket - connector
PAC-SG64DP-E MXZ-SB48NA Drain pan
RCMKP1CB lVI-Series Wireless Lockdown bracket for remote controller
lILTRILlTE1 All M-Series Condensing unit mounting pad 16 x 36 x 3
MITSUBISHI ELECTRIC 27
MXZ-8 Series Port Adapter chart Port Adapter Unit Port
Combinations Required Size
MXZ-2B20NA-1
2-zone combinations wi NA
A 38 x both units s12K 14
1-MAC-A454JP-E B 38 x
6+15 14
9+15 1-MAC-A454JP-E
MXZ-3B24NA
All rated 2-zone combina-NA
A 12 x tions 14
All rated 3-zone combina-NA
B 38 x tions 14
C 38 x 14
MXZ-3B30NA
2-zone combinations wi at NA
A 12 x least one unit s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
9 + 24 14
3-zone combinations wi 1-MAC-A455JP-E
all units s12K
All other rated 3-zone NA
comb
MXZ-4B36NA
2-zone combinations wi at NA
A 12 x least one un it s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
6 + 24 14
1-MAC-A456JP-E D 38 x
9 + 24 14
3-zone combinations wi at NA
least two units s12K
3-zone combinations wi 1-MAC-A454JP-E
two units15K
6+6+24 or 6+9+24 1-MAC-A456JP-E
9+9+24 1-MAC-A456JP-E
4-zone combinations wi at 1-MAC-A455JP-E
least three units s12K
6+6+15+15 1-MAC-A454JP-E
6+6+15+15 1-MAC-A454JP-E
Note When using the Pu-A24BA PCA-A24KA or PEAD-A24AA two port adapter will be needed 1-MAC-A456JP-E (12 x 58) A port or 1-PACshySG76RJ-E (38 x 58) B C and D ports and 1-PAC493PI (14 x 38)
28 JMITSUBISHI ELECTRIC
6+6+246+9+24 6+12+249+9+24 9+12+24 or 12+12+24
6+15+24 6+18+24 9+15+249+18+24 12+15+24 or 12+18+24
15+15+24 15+18+24 or 18+18+24
15+24+24 or 18+24+24
Combinations of 4 or more zones
1-PAC-SG76RJ-E
See notes for application below
2
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
See notes for application below
PORT A =38 gas x 14 liquid
PORT B =38 gas x 14 liquid
PORT C =38 gas x 14 liquid
PORT A =38 gas x 14 liquid
PORT B = 38 gas x 14 liquid
PORT C = 38 gas x 14 liquid
PORT D =38 gas x 14 liquid
PORT E =12 gas x 14 liquid
Notes for application bull Check the lineset sizes for your indoor selected models bull Select the branch box or boxes needed for your application bull Compare indoor unit lineset sizes as compared to branch
box sizes bull Connect 15K + indoor units to the larger port on the
(PAC-AKA51 BC) bull Adapt lineset size with appropriate port adapter from
above list bull When using the PU-A24BA or PEAD-A24AA two port
adapter will be needed 1-MAC-A456JP-E (12 x 58) or 1-PAC-SG76RJ-E (38 x 58) and 1-PAC493PI (14 x 38)
-fv
~ DIAMONDBACKtrade
~) BV-Series Ball Valves Model numbers
BV14FFSI BV38FFSI
LISTED 891N REFRIGERANT
BV12FFSI VALVE bull Engineered for Mini-split andBV58FFSI
Multi-split HVAC Units bull Size available 14 38 12 58
bull Full Port Designbull Fully factory assembled bull Furnace brazed and pressure tested bull 700 PSIG Rated bull Each ball valve is equipped with Schraderreg Valve
for refrigerant service bull R-410A Compatible bull Design working pressure 700 PSIG bull Temperature range bull Flare Connections
-40 0 F to +3250 F (-400 C to + 1490
C) bull Forged brass body and seal cap bull Teflonreg seals and gaskets (no synthetic a-rings) bull Seal cap design permits valve operation without
removal of seal cap bull Suitable for use with R-11 R-22 R-123 R-125
R-134A R-236FA R-4202A R-402B R-404A R-407C R-410A R-500 R-502 and R-507
bull One year limited materials and workmanship
Part Number SAE Flare
A B C 0 E F
BV14FFSI 14 619 260 180 122 142 110
BV38FFSI 38 630 267 180 122 142 110
BV12FFSI 12 651 267 180 122 142 110
BV58FFSI 58 664 267 180 128 142 110
Ball valves come With an insulation piece warranty on Ball Valves
~ DIAMONDBACKtrade
~) Platform Stands
Lift the Mitsubishi Electric Comfort Solution
outdoor unit to new heights with our Diamondback Platform Stands
bull Easy to install
bull Available for all sizes of Mr Slim outdoor units
bull Color matched to the outdoor units
Model Number DSD-400N
L 15-34 x W 3-14 x H 3-14
r
)MITSUBISHI ELECTRIC 29
~ DIAMONDBACKtrade LINESETS
~~
Twin-Tube Lineset Insulation Design
bull Balanced outside diameter for uniform coiluncoil position stability
bull Minimum 12 insulation thickness on both tubes Diamondback Advantages include the following features
bull Quick efficient and economical field installation using factory applied Twin Tube insulation and flare connections with flare nuts mounted
bull Correct lengths for reducing waste and time
bull Quality consistency and economy
bull All Diamondback Lineset tubing is tested in accordance with ASTM E243
Filter Boxes
FB Series filter boxes are available in compatible sizes for all Mr Slim horizontal ducted indoor units
FBL 1 filter boxes include 1 thick pleated MERV 8 filter(s) installed Filters are tested in accordance with ANSIASHRAE Standard 522 and Rated Class 2 under UL Standard 900
The cabinet is constructed of non-insulated 20 gauge G-60 galvanized
FBL1-1 FB Series Filter Box for SEZ-KD09NA
FBL1-2 FB Series Filter Box for SEZ-KD12KD15-NA
FBL1-3 FB Series Filter Box for SEZ-KD18NA
steel with foam gasket and provides an air-tight connection to indoor unit and access door Gasket material complies with UL 723 requirements
A screw-through cabinet design for secure attachment to indoor unit and return connection in rear is easily field-converted to bottom return
30 MITSUBISHI ELECTRIC
bull
bull
bull
bull
bull
bull
LINE-HIDE~ Put a professional finish on air-conditioning
installations with an easy-to-install modular
system that beautifies exteriors and
protects Linesets drainlines and wiring
Can be use it indoors too Meets UL94v-O for interior applications
Has snap-on covers and a full selection of couplings elbows T-joints caps and more for any application complex or simple
Offers high-quality PVC with UV inhibitors for outdoor service in all weather conditions
Can be painted with most house paints to match exterior decors
Is not just for HVAC Hide any exterior cabling piping or wiring
Available in four sizes 2-14 3 4 and 6 tubes
Download a brochure at wwwline-hidecom to find out more information
For more information on our CITY MULTI VRF product line visit our website at wwwmitsubishiprocom
_lIJrUlllln ~ ~IIII1 fInll l
~
l bull bull
JMITSUBISHI ELECTRIC 31
MULTIPLE ROOMS WITH INDIVIDUAL CONTROL FROM A SINGLE SYSTEM Enjoy ideal levels of comfort in the rooms you use most with our multi-room system Each room (zone) operates independently People in different rooms - the kitchen master bedroom or living room - can enjoy temperature settings that make each of them most comfortable
If you re looking for a complete comfort solution for several different rooms the MXZ multi-room system is the right choice The system is flexible enough to conform to a particular cooling and heating need and offers numerous different indoor unit combinations In addition up to eight indoor units can be connected to one outdoor unit Now with a SEZ horizontal ducted unit and a MFZ floorshystanding unit homeowners can enjoy an even greater range of zoning options provided by an MXZ system
An MXZ multi-room system is an excellent choice for supplementing capacity to a current system conditioning newly furnished spaces or new additions and replacing a system within a home Homeowners can also benefit from lower energy costs year-round while staying comfortable thanks to Mitsubishi Electrics energy-efficient technologies that are a part of every system that we make
To add to the level of energy efficiency the MXZ -2B20NA and MXZ -3B24NA systems qualify for both ENERGY STARreg and the federal tax credit (See details on page 21 for applicable indoor unit combinations)
At right a single level home with several system types represented (For illustrative purposes only)
MFZ Floor-Standing Indoor Units for MXZ Heat Pump Systems
Floor-standing indoor unit mounts three inches above the floor and has front panel access to the filter for ease of cleaning
The MFZ units provide energy-efficient solutions to provide personalized comfort for difficult areas that may be smaller or dont have usable space on the walls
MFZ units on MXZ systems include the following features bull Top and bottom discharge vanes bull Hot-start technology bull Quiet operation bull Wireless remote control (optional wall-mounted controller)
18 MITSUBISHI ELECTRIC
MSZ Wall-Mounted Indoor Units for MXZ Heat Pump Systems
Providing a wide range of cooling and heating capacities each wall-mounted indoor unit mounts high on a wall and connects to a branch box or the outdoor unit by a refrigerant line run via a 3 hole The MSZ units provide highly efficient solutions to cooling and heating needs and provide personalized comfort for the individual zones in which they are installed
MSZ units on MXZ systems include the following features bull Sleek flat panel design bull Hot-start technology bull Quiet operation bull i-seeM sensor technology (MSZ-FE0912NA models only) bull Enhanced filtration system (MSZ-FE0912NA models only) bull Wireless remote control (optional wired wall-mounted controller)
SLZ Ceiling-Recessed Indoor Units for MXZ Heat Pump Systems
The new SLZ-KA ceiling casette systems offer a wide air-flow pattern for better air distribution
offered to your customers Installation can be done in a hard ceiling (with a access panel for servicing) or placed into a 2x2 drop ceiling With a built-in drain lift mechanism for condensate
removal and a 4 ventilation air intake knockout option the SLZ is ready to handle a variety of installation needs
SLZ units on MXZ systems include the following features bull Wide air-flow pattern for better air distibution bull 4 ventillation air intake knockout bull Built-in condensate lift mechanism bull Wireless RedLlNKTM remote controller
SEZ Horizontal Ducted Indoor Units for MXZ Heat Pump Systems
SEZ ducted units can provide split air-conditioning system advantages with the added benefit of being concealed to provide virtually no visual footprint within the conditioned space other than a register and grille for the air to flow With the use of short run ductwork these units can provide comfort to a single room that needs air dispersed evenly throughout the space unusually shaped rooms and adjacent rooms
The SEZ unit on MXZ systems include the fOllvowin fatures _
g~e~~~~==Zl[bull Concealed design for short-run ductwork bull Quiet operation bull Built-in condensate lift mechanism
JMITSUBISHI ELECTRIC 19
s c t
I
N o J ro o ltro ~ ro ~
DIAMOND COMFORT MXZ MULTI-ZONE SYSTEMS MXZ-B Series multi-zone systems provide personalized comfort control and energy efficiency in up to eight rooms with only a single outdoor unit The MXZ-B Series system features include
bull Individual zone control bull Mix and match flexibility of indoor unit styles and combinations bull A wide range of indoor unit capacities that match the room size and requirements bull Flexible design options to tackle the most challenging multi-room installations bull Efficient systems including three systems [mxz series] that meet energy starltID and
federal tax credit requirements bull Simple quick and cost-effective installation keeps install costs down on new construction
and disruption to a minimum on renovations and refits
Efficiency and performance ratings depend on the number style and capacity of the indoor units installed with each Multi-Zone System
MXZ -2 B20 NA - 1 (2 1 ) MXZ -3 B24 NA (2 13 1) Ou tdoo r Unit Outdoor Uni t
MSZ-GE09NA Indoor Units
SEZ-KD12NA Indoor Unit
MSZ- GE06NA
~~~~li
(At least two indoor units MSZ-GE06NAIndoor Unit must be installed) Indoor Unit
(Two indoor units must be installed )
MXZ -3 B30 NA (2 1 3 1) Outdoor Unit
SEZ-KD12NA Indoor Unit
~~~i
(At least two indoor units MSZ-GE06NA must be installed)
Indoor Unit ~
MFZ- KD12NA Indoor Unit
MXZ-8B48NA (2 1-8 1) Outdoor Unit
(At least two indoor units
must be installed)
(At least two indoor units must be installed)
MFZ-KD09NA Indoor Units
MSZ-GE09NA Indoor Units
SEZ-KD12NA Indoor Unit
MSZ INDOOR UNIT
MSZ-FE18NA
PEAD HORIZONTAL -DUCTED INDOOR UNIT
PEAD-A24AA
MSZ INDOOR UNIT SEZ HORIZONTAL-DUCTED MSZ-FE18NA
INDOOR UNIT MFZ FLOOR-STANDING SEZ-KD18NA INDOOR UNIT
MFZ-KA12NA
20 AMITSUBISHI ELECTRIC
MULTI-ROOM MXZ-8 INVERTER HEAT PUMP R
Model Name Outdoor Unit MXZ-2B20NA-1 5 MXZ-3B24NA 6 MXZ-3B30NA MXZ-4B36NA 7
Indoor Unit
Cooling 1 Non-ductedl Ducted
Rated Capacity Btuh 1800020000 2200023600 28400127400 3540034400
Capacity Range Btuh 7800-20000 12600-25500 12600-28400 12600-36400
Total Input W 2190 (630-219QL 2460 (1000-2950) 3330 l1 000-3330) 3 940 (1 000-4020)
Heating at 4JO F 2 Non-ductedl Ducted
Rated Capacity Btuh 2200022000 2500024600 2860027600 3600034400
Capacity Range Btuh 8500-25500 11400-30600 11 400-36000 11400-43000
Total Input W 2620 (520-2620) 1900 (740-2600) 2220 (740-2820) 3100 (740-3940)
Heating at 1JO F 3 Non-ductedl Ducted
Rated Capacity Btuh 1250012500 1400014000 1600015100 2220020300
Rated Total Input W 13501430 13801570 21202 140 24302340
Maximum Capacity Btu h 1450014500 1880017000 1880018000 2460025400
Maximum Total Inl2ut W 15001590 21202230 21202140 33403450
Power Supply Phase Cycle Voltage 1-phase 60Hz 2081 230V 8
Voltage Indoor shy Outdoor S1 - S2 AC 2081 230V
Indoor shy Outdoor S2 - S3 DC12-24V
Outdoor Unit 4
MCA A 15 19
MOCP A 20
Fan Motor FLA 096 093
Compressor
Model (Type)
DC INVERTER-driven Twin Rotary
RLA 101 11 144
LRA 15
Airflow (CoolingHeating) CFM 14851 640 20681605 13651605 20682068
Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1
dB(A) 49 54 49 54
Sound Pressure Level at Heating 2
dB(A) 51 49 57
External Finish Color Munsell No 30Y 781 1
Dimensions
W In 33-116 35-716
D In 13 12-58
H In 27-1516 35-7116
Weight Lbs 130 150 153
Indoor Unit No of Units 2 23 23 234
Remote Controller Type Associated with the Indoor Unit
Refrigerant
Type R410A
Charge Lbs Oz 515 7 11 813
Oil Type (fl oz)
NE022 (237) NE022 (294)
Refrigerant Pipe Gas Side 00 In AB 38 A 12 BC 38 A 12 BCD 38
Liquid Side 00 In 14
Refrigerant Pipe Length Height Difference (Max) Ft 4933 9
Length (Max) Ft 164 (A+B) 230 (A+B+C) 230 (A+B+C+D)
Connection Method IndoorOutdoor FlaredlFlared
Compatible with the MSZ-A MSZ-GA MSZ-FD MSZ-FE MSZ-GE MFZ-KA and SEZ-KD series indoor units (PLA-18 amp PCA-24 on the MXZ-MXZ-3B PLA-24 amp PCA-24 on the MXZ-4B)
NOTES Test conditions are based on AHRI 210240 One indoor unit is turned off during low-speed testing under the new test conditions Systems actually exhibit higher energy efficiencies during normal operation
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F (35deg C) WB 75deg F (24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F (6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 600 F (160 C) Outdoor DB 17deg F (_80 C) WB 150 F (_90 C) 4 Refer to pages 12 and 13 for Indoor Unit specifications 5 Data from combination of two Indoor Units 9000 Btuh (non-ducted) or one 9000 Btuh and one 12000 Btuh (ducted) 6 Data from combination of two Indoor Units 6000 Btuh and one 9000 Btuh (non-ducted) or three 9000 Btuh (ducted) 7 Data from combination of four Indoor Units 9000 Btuh (non-ducted and ducted) 8 Indoor units receive power from outdoor units through field-supplied interconnected wiring 9 49 Applies to installations where the outdoor unit is installed below the indoor unit
Power factor equals 97 percent
Specifications are subject to change without notice
MULTI-ZONE ENERGY STAR AND TAX CREDIT SYSTEMS
Model Indoor Unit Combinations SEER HSPF
MXZ-2B20NA-1 2 x MSZ- GE09NA 18 8 9
MXZ- 3B24NA 2 x MSZ- GE06NA 1 x MSZshy GE09NA
17 5 9 3
MXZ- 3B24NA 2 x MSZ-GE06NA 1 x MSZ- GE12NA
17 5 93
For more details on all ENERGY STAR and tax credit systems go to wwwmitsubishicomfortcomtaxcredit
See page 25 for additional info on efficiency
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 21
MXZ-8B48NA THE ULTIMATE ZONING SOLUTION
The Mitsubishi Electric MXZ-S84SNA eight-zone unit As a member of the expanding MXZ-B Series of multi-zone systems the MXZ-8B outdoor unit incorporates branch boxes to connect up to eight indoor units MXZ- 8 B48 NA (2 1 - 8 1 )
Outd oor Uni t The INVERTER-driven compressor at the heart of the MXZ-8B -~-- shy
outdoor unit provides variable capacity control allowing the system to adjust to the specific demands of the interior space ~ as needed not the hard start and stop of a traditional system I[iDA Jinstalled in most US homes
The MXZ -8B48NA has only one port on the outdoor unit for two insulated refrigerant lines which run into the home or business to connect to a branch box or boxes From the branch box(es) gas and liquid refrigerant piping run to each of the indoor units The LEV in the branch box(es) controls the refrigerant flow as the load of each zone changes
Through the branch box(es) (the PAC-AKA31 BC three-port andor the PAC-AKA51 BC five-port) the system can connect from two indoor units up to eight indoor units depending on application requirements
The flexibility of the system doesnt stop there The MXZ-8B48NA has rated capacities of 48000 Btuh for cooling and 54000 Btuh for heating System operation however can range from a minimum 12000 Btuh to a maximum 54000 Btuh in cooling and a maximum of 60000 Btuh in heating This type of performance supports a large variety of applications
The MXZ-8B48NA allows for further flexibility because it supports a connected indoor unit capacity from 22 to 130 or 12000 Btuh to a maximum 70200 Btuh depending on diversity
Connectable Indoor Units General Features bull Four-ton outdoor unit can support up to
eight indoor units using branch boxes bull Wide variety of indoor unit styles
-=--_-=-----= - - J _ 1
including wall-mounted floor-standing MSZ-FE09 12 18NA MSZ-GE06 09 12 15 18 24NA ceiling-cassette ducted
bull Individual control up to eight (8) zones using wired or wireless controls
bull Advanced microprocessor control bull Auto restart following a power outage bull Self-check function offering SEZ-KD09 1215 18NA PEAD-A24AA
integrated diagnostics ~--- Jbull Limited warranty five years on parts and
defects and seven years on compressors
SLZ-KA09 1215NA MFZ-KA09 12 18NA
22 MITSUBISHI ELECTRIC LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
I
RMULTI-ROOM MXZ-8 INVERTER HEAT PUMP
Model Name Outdoor Unit MXZ-BB4BNA Cooling 1 Rated Capacity
Non-ducted Rated Total Input Ducted
Maximum Capacity
Rated CapacityHeating at
Rated Total InputIndoor Unit 4JO F 2 Non-
ductedDucted Maximum Capacity
Rated Capacity Heating at
Rated Total InputlJO F 3 Non-ductedDucted Maximum Capacity
Power Supply Phase Cycle Voltage
Indoor - Outdoor Sl - S2 Voltage
Indoor - Outdoor S2 - S3
MCA
Recommended FuseBreaker Size
Fan Motor
Compressor
Airflow (CoolingHeating)
Refrigerant Control
Outdoor Unit Sound Pressure Level at Cooling 1
Sound Pressure Level at Heating 2
External Finish Color
Dimensions
Weight
Total Capacity 22-130
Indoor Unit ModelQuantity
Remote Controller Type
Type
Refrigerant Charge
Oil
Gas Side OD Refrigerant Pipe
Liquid Side OD
Height Difference (Max)
Maximum Distance between (Outdoor unit and farthest indoor unit)
Refrigerant Pipe Length Maximum Pipe Length -Branch box to Indoor Unit
Total Maximum line length between Branch Box and All Connected Indoor Units
Total Length (Max)
Connection Method IndoorOutdoor
Includes both branch boxes if there are two
Branch Boxes (At least one branch box required)
Btuh
W
Btuh
Btuh
W
Btuh
Btuh
W
Btuh
A
A
Type x Quantity
Motor Output (kW)
Model (Type)
Motor Output (kW)
CFM
dB(A)
dB(A)
W In
D In
H In
Lbs
Btuh
Lbs Oz
Type (fl oz)
In
In
Ft
Ft
Ft
Ft
Ft
4800048000
57806470
54000
5400054000
48205270
60000
3300034700
29503390
3660036550
1 Phase 60Hz 208 230V
AC 208-230V
DC12-24V
32
40
Propeller x 2
0086 + 0086
DC INVERTER-driven Scroll
29
3530
Linear Expansion Valve
54
55
Munsell No 3Y 78 11
37-716
13+1-3 16
53-3 16
278
12000 - 70200
600 - 24000 2-8
Associated with Indoor Unit Model
R410A
18 112
FV50S (73)
58
38
6698 4
230
49
197
377
FlaredFlared
Compatible with the MSZ-A MSZ-FO MSZ-FE MSZ-GE MFZ-KA SEZ-KD PLA and PEAD series indoor units
NOTES Test conditions are based on AHRI 210240 One indoor unit is turned off during low-speed testing under the new test conditions Systems actually exhibit higher energy efficiencies during normal operation
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F (35deg C) WB 75deg F (24deg C)
2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 4]0 F (8deg C) WB 43deg F (6deg C)
3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 17deg F (-8deg C) WB 15deg F(-9deg C)
4 66 applies to installations when the outdoor unit is installed below the indoor unit
Power factor equals 97 percent
Specifications are subject to change without notice
Note Maximum installed capacity is the maximum total of all connected indoor units NOT the maximum capacity produced
Only a single Lineset is needed from the outdoor unit to branch box
See page 25 for MXZ-B information on efficiency
Required Branch Boxes for MXZ-SB4BNA (Maximum of 2 branch boxes can be connected to one outdoor unit requires joint MSDD-50AR-E or MSDD-50BR-E)
s c d N o J ro Vl
0 ro n 3i n OJ d o J U)
PAC-AKA51 BC Branch Box
PAC-AKA31 BC Branch Box LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 23
MSZ WALL-MOUNTED INDOOR UNITS (FOR MXZ-8 OUTDOOR UNITS)
R
(MSZ-GE12NA MODEL SHOWN)
-000 IIIIIII 9000 9000 12000 12000 14000 17200
Heating at 4r Rated Capacity Btuh 7200 10900 10900 14400 13600 18000 21600
F2 Power Supply I Phase Cycle Voltage J -phase 60Hz 208 230V 3
Iindoor Outdoor S1 S2 AC 208 230V
Iindoor Outdoor S2 S3 DC12-24V Voltage
Iindoor Remote vomr Iller Wireless Type (Optional Wired vomroller DC 12V)
IMCA A 10 IFan Motor FLA 076
DRY 162-226shy145-170shy
162-226shy205-272shy 230-275shy
Airflow at Cooling (CFM)
145-170-237-321-399 339-381
237 -321shy381-410
335-420shy 339-420shy(Quiet-Lo-Med-Hishy 399 533 533 Super Hi or Lo-Med-
WET 144-202shy109-134shy
144-202shy170-237shy 194-240shy
Fan Hi-Powerful)1 (CFM)
109-134-201-286-364 307-343
201-286shy350-367
300-385shy 304-385shy364 498 498
Airflow at Heating 145-170shy 145-170shy 145-170shy 205-247shy 230-275shy
(Quiet-Lo-Med-Hi- WET 233-321shy 237-321shy
166-240shy237-321shy
166-240shy304-367shy 339-431shy
Super Hi or Lo-Medshy (CFM) 406 406
367 -381 406
399-420 463 512
Hi-Powerful) 2 Sound Pressure Level at Cooling
19-22-30shy 26-32-38shy 28-33-38shy(Quiet-Lo-Med-Hi-Super Hi or Loshy dB(A) 19-22-30-37 -43 22-31-39-42
37-45 22-33-43-45
44-49 44-49Med-Hi-Powerful) 1
Sound Pressure Level at Heating 19-22-30shy 26-30-35shy 28-33-38shy
(Quiet-Lo-Med-Hi-Super Hi or Loshy dB(A) 19-22-30-37 -43 22-31-40-42 37-43
22-23-43-44 40-46 43-48
Med-Hi-Powerful) 2
I External Finish Color Munsell No 10Y 92 02
IWln 31 middot716
Dimension Unit 10 In 9 18 10-18 9middot18 10-18 9-18
IH In 11-58
I Weight Unit ILbs 22 27 22 27 22 I Field Drainpipe ~D lin 58 Remote Con-
Type Wireless Remote (Optional Wired Controller) troller
ITvpe B41QA Refrigerant ~s$ideOD lin 38 Pipe I Liquid Side 00 In 14
Connection IndoorOutdoor FlaredFlared
Method
1~
II 18000 22500
21600 27600
388-469shy 38$-469shy628-738 628-738
347-420shy 347-420shy562-661 562-661
388-469shy 388-469shy628-738 628-738
34-41-49-53 34-41-49-53
32-41-49-52 32-41-49-52
43-516
9-38
12-1316 37
58 38
MXZ-2B20NA is also compatible with the MSZ-A and MSZ-FD series indoor units NOTES Test conditions are based on AHRI 210240
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F(6deg C) 3 Indoor units receive power from outdoor units through field-supplied wiring
Specifications are subject to change without notice LIMITED WARRANTY Seven-year warranty on compressor Five-year warranty on parts For data on specific indoor unit combinations see page 21
SEZ DUCTED INDOOR UNIT (FOR MXZ-8 OUTDOOR UNITS)
I
Notes 1 Cooling-Indoor DS 80deg F(267deg C) WS 67deg F(194deg C) Outdoor DS 95deg F (35deg C) WS 75deg F(239deg C)
2 Heating-Indoor DS 70deg F(211 deg C) WS 60deg F(156deg C) Outdoor DS 47deg F (83deg C) WS 43deg F(61 deg C)
3 External static pressure is factory set to 006 WGAdjustable via the
1---------t---+-----L-------------1~---__I PAR-21MAA
1--_____----__________+-____---L____----~_____________1 4 Indoor units receive power
jE~~~~-------------r----1-----~-~~~~~~~~-----___1 from outdoor units through fieldsupplied interconnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven-year warranty on compressor Five-year
1---------------------+---+------------------------1 warranty on parts
~--__I_~----------+-------~l----------I For data on specific indoor unit combinations see page 21 - 23
I--~------+~-----------~----------r_------------I
- Reference page 17 for SEZ static performance curves
24 MITSUBISHI ELECTRIC
25-30-35-40 26-31-36-41 35-38-42-46
25-30-35-40 28-31-36-41 35-38-42-47
MFZ FLOORLOW WALL INDOOR UNIT (FOR middotMXZ-8 OUTDOOR UNITS)
------shy
-==
Airflow at Heating (CFM) 177-198-219-332 184-201-219-335 261-275-297-434
Voltage
Fan
Airflow at Cooling (Lo-Med-Hi-Super Hi)1
169-205-251-314 251-279-325-394
163-197-241-303 170-207-252-309 241-269-313-379
(Lo-Med-Hi-Super Hi) 2
SLZ CEILING-RECESSED INDOOR UNIT (FOR MXZ-8 OUTDOOR UNITS) EFFICIENCY RATINGS
Voltage
Fan
Galvanized-steel SheetsMunsell 64Y 89 04
Refrigerant Pipe
Model Indoor Unit Type SEER HSPF
MXZ-2B20NA-1
Non-dueted 18 89
Dueted and Non-dueted 1675 87
Dueted 155 85
MXZ-2B20NA-1 ENERGY STAR amp
TAX CREDIT 2 x MSZ-GE09NA 18 89
MXZ-3B24NA
lJon-dueted 175 93
Dueted and Non-dueted 1625 89
Dueted 150 85
MXZ-3B24NA ENERGY STAR amp
TAX CREDIT
2 x MSZ-GE06NA 1 x MSZ-GE09NA
175 93
MXZ-3B24NA ENERGY STAR amp
TAX CREDIT
2 x MSZ-GE06NA 1 x MSZ-GE12NA
175 93
MXZ-3B30NA
Non-dueted 175 105
Dueted and Non-dueted 16 100
Dueted 145 95
MXZ-4B36NA
Non-dueted 18 93
Dueted and Non-dueted 16 5 92
Dueted 150 9 0
MXZ-BB4BNA
Non-dueted 15 87
Dueted and Non-dueted 14B B8
Dueted 147 89
Connection IndoorOutdoor FlaredFlared
Method
Notes 1 Cooling-Indoor DB 80deg F(267deg C) WB 67deg F(194deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(239deg C) 2 Heating-Indoor DB 70deg F(21 1 deg C) WB 60deg F(156deg C) Outdoor DB 47deg F(83deg C) WB 43deg F(61 deg C) 3 Indoor units receive power from outdoor units through field supplied interconnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 25
Notes 1 Cooling-Indoor DB 80deg F(267deg C) WB 67deg F (194deg C) Outdoor DB 95deg F (35deg C)WB 75deg F (239deg C)
2 Heating-Indoor DB 70deg F(211deg C) WB 60deg F (156deg C) Outdoor DB 47 F (83deg C) WB 43deg F (61 deg C)
3 Indoor units receive power from outdoor units through field supplied interco(lnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven -year warranty on compressor Five-year warranty on parts
Presently there is no 1 1 system with the MFZ indoor unit
s c
N o J ro Vl
C ro n ~ n OJ t o J V)
M-SERIES RATING CONDITIONS
INDOOR INTAKE AIR TEMPERATURE
OUTDOOR INTAKE AIR TEMPERATURE
COOLING
MAXIMUM
95degF DB 71 degF WB (MU SUZ MXZ-2B20-13B243B304B36) 90degF DB 73degF WB (MUZY-GE MUZ-FE MUzy-D)
115degF DB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B24 3B304B368B48)
MINIMUM 67degF DB 57degF WB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B201 3B243B304B36)
14degF DB (MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B24 3B304B36) 23degF DB (MXZ-8B48) 6rF DB (MU)
MAXIMUM 80degF DB 6rF WB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B243B304B36)
75degF DB 65degF WB (MUZY-GE MUZY-GA24 MUZ-FE SUZ MXZ-2B20-1 3B243B304B36) 70degF DB (MXZ-8B48)
HEATING
MINIMUM 70degF DB 60degFWB (MUZ-GE MUZ-GA24 MUZ-D MUZ-FE SUZ MXZ-2B20-1 3B243B304B36)
-13degF DB -15degFWB (MUZ-FE) -4degF DB -5degF WB (SUZ MUZ-GE) 5degF DB 4degF WB (MUZ-GA24 MXZ-8B48NA) 6degF DB 5degF WB (MXZ-2B20-1 3B24 3B304B36) 14degF DB 13degFWB (MUZ-D)
MU units operate at intake air temperature down to 10deg Fwith the addition of an ICM-326HM-1 low temperature control
REFRIGERANT TUBING SETS
OPTIONAL ACCESSORIES
REFRIGERANT LINE LENGTH FLARE FLARE _INDOOR UNIT OUTDOOR UNIT
MS-A09WA MU-A09WA 35 MS-A12WA
65 MU-A12WA 35
MSY-GE09NA 65
MUY-GE09NA 40
MSY-GE12NA
65
MUY-GE12NA 65 40
MSY-GE15NA MUY-GE15NA 40
MSY-GE18NA
65
MUY-GE18NA 100 50
MSZ-GE09NA MUZ-GE09NA 65 40
MSZ-GE12NA MUZ-GE12NA 40
MSZ-GE15NA
65
MUZ-GE15NA 40
MSZ-GE18NA
65
MUZ-GE18NA 100 50
MSY-GE24NA MUY-GE24NA 100 50
MSZ-GE24NA MUZ-GE24NA 100 50
MSY-D30NA MUY-D30NA 100 50
MSZ-D30NA MUZ-D30NA 50
MSY-D36NA
100
MUY-D36NA 50
MSZ-D36NA
100
MUZ-D36NA 100 50
MSZ-FE09NA MUZ-FE09NA 40
MSZ-FE12NA
65
MUZ-FE12NA 40
MSZ-GE06091215NA MSZ-FE0912NA
65
MXZ-2B20NA-1 164 4933MFZ-KA0912NA SEZ-KD09 1215NA
MSZ-GE0609 121518NA MSZ-FE091218N MFZ-KA09 1218NA MXZ-3B24NA 164 4933 SEZ -KD09 12 15 18NA SLZ-KA09 12 15NA
MSZ-GE0609 121518NA MSZ-GA24NA MSZ-FE091218NA
MXZ-3B30NA 4933230MFZ-KA091218NA SEZ -KD09 121518NA SLZ-KA09 12 15NA
MSZ-GE0609121518NA MSZ-GE24NA MSZ-FE09 12 18NA
MXZ-4B36NA 230 4933MFZ-KA091218NA SEZ -KD09121518NA SLZ-KA09 12 15NA
MSZ-GE0609 12 15 18NA MSZ-GE24NA MSZ-FE09 12 18NA
MXZ-8B48NA 6698377MFZ-KA091218NA SEZ-KD09121518NA SLZ-KA09 12 15NA
PART NUMBER I USE WITH I DESCRIPTION
Port Adapters and Connection Pipes MAC-A454JP-E MXZ-Series Adapter 38 X12
MAC-A455JP-E MXZ-Series Adapter 12 X38
MAC-A456JP-E MXZ-Series Adapter 12 X58
MSDD-50AR-E MXZ-Series Branch Box Tee Distribution Pipe - Flare Connection between two branch boxes
MSDD-50BR-E MXZ-Series Branch Box Tee Distribution Pipe - Braze Connection between two branch boxes
PAC-493PI MXZ-Series Adapter 14 X38
PAC-SG76RJ-E MXZ-Series Adapter 38 X58
OPTIONAL ACCESSORIES CONTINUED ON NEXT PAGE
49 amp 66 applies to installations in which the outdoor unit is installed below indoor unit26 MITSUBISHI ELECTRIC
OPTIONAL ACCESSORIES (CONTINUED)
PART NUMBER USE WITH DESCRIPTION Control Options and Accessories
M21 JKO 307 M-Series Indoor Units Remote temperature sensor for M-Series indoor units
MAC-397IF-E
MAC-399IF-E
PAC-YU25HT
PAR-21 MM-G
M-Series INVERTER Units
M-Series INVERTER Units
SEZ-KD Indoor Units
Use with P-Series SEZ and for wired M-Series Controller
MA and contact terminal interface - Required to use PAR-21 MM wired wall mount controller with M-Series Systems
CMCN M-NET control adapter I Interface for Mr Slim M-Series MSYZ SEZ I MFZ
External Fan I Heater control relay adapter
Deluxe MA remote controller (Requires MAC-397IF-E for use with M-Series - MSYZ MFZ)
SEZ Wireless remote controller for SEZ units (Requires signal receiver PAR-SA9FA-E)PAR-FL32MA
PAR-SA9CA-E SEZ Wireless signal receiver for SEZ
3-pole disconnect switch 30A 600V turns off power between indoor and outdoor units shyM-SeriesTAZ-MS303
mounts in 2 X 4 utility box and requires standard single gang switch platecover - Low Ambient
ICM-326HM-2 M-Series Non-INVERTER units Low ambient head pressure controller MUZ-GE091215 IVIUZ-FE0912 SUZ-KD091215
Drain pan heaterMAC-640BH-U outdoor unit
MAC-641 BH-U MUZ-GE18 SUZ-KD18 outdoor unit Drain pan heater Filters
MAC-1415FT-E Anti-allergy enzyme filter
MAC-2300FT
MSZlMSY-D3036
Anti -allergy enzyme filter
MAC-308FT
MSYMSZ-GA24
MSZ-FD912 I FE0912 Platinum deodorizing filter
MAC-408FT-E Anti-allergy enzyme filter
MAC-415FT-E
M-Series Indoor Unit - GE09GE12GE15GE18
MFZ-KA Air Cleaning FilterAnti-Aliergy Enzyme Filter
MAC-418FT Anti-allergy enzyme filter
Filter Boxes
FBL1-1
MSZ- FD912 I FE091 2
FB Series Filter Box for SEZ-KD09NA Optional filter box with MERV 8 filters
FB Series Filter Box for SEZ-KD1215NAFBL1-2 Optional filter box with MERV 8 filters
and PEA-A 12M
FBL1-3 FB Series Filter Box for SEZ-KD18NA Optional filter box with MERV 8 filters
Pumps
SI1730-230 MSYZ - 30000 Btuh or greater Sauermann mini condensation pump 230V
S13100-115 MS-Series - non-INVERTER Sauermann mini condensation pump 115V
S13100-230 Sauermann mini condensation pump 230VMSYZ - Less than 30000 Btuh
Miscellaneous BRP-1 Bottom Return Plate for SEZ-KD09NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-2 Bottom Return Plate for SEZ-KD12KD15-NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-3 Bottom Return Plate for SEZ-KD18NA Converts low profile ducted indoor unit from rear return to bottom return
BV12FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderreglnsulated - 12
BV14FSI Use with any Mr Sl im multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 14
BV38FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 38
BV58FSI Use with any IVIr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 58
Condensing unit wall mounting brackets (set of 2) - 440 lb capacity painted steel NOTE CWMB1 IVIU and PU outdoor units Installer is responsible to select and provide suitable hardware and materials to insure proper
mount of bracket to wall
DSD-400N M-Series DiamondBacktrade Platform Stands MUZ-GE18 I MUZ(y)-03036 I
MAC-811DS Drain socket assemblySUZ-KA18
MAC-851DS MUZ-FD0912 Drain socket
MAC-855SG M-Series Air outlet guide
MAC-856SG M-Series Air outlet guide - MXZ-3B24 I 3B30 I 4B36 NA
MAC-860DS MUZ-GE091215 I MUZ-FE0912 Drain socket
MAC-889SG M-Series Air outlet guide- MXZ-2B20NA
MAC-S99SG M-Series Air outlet guide
PAC-SG59SG-E IVIXZ-SB4SNA Air outlet guide (1 piece) I MXZ-SB48NA (Requires 2 pieces)
PAC-SG61 DS-E MXZ-8B4SNA Drain socket - connector
PAC-SG64DP-E MXZ-SB48NA Drain pan
RCMKP1CB lVI-Series Wireless Lockdown bracket for remote controller
lILTRILlTE1 All M-Series Condensing unit mounting pad 16 x 36 x 3
MITSUBISHI ELECTRIC 27
MXZ-8 Series Port Adapter chart Port Adapter Unit Port
Combinations Required Size
MXZ-2B20NA-1
2-zone combinations wi NA
A 38 x both units s12K 14
1-MAC-A454JP-E B 38 x
6+15 14
9+15 1-MAC-A454JP-E
MXZ-3B24NA
All rated 2-zone combina-NA
A 12 x tions 14
All rated 3-zone combina-NA
B 38 x tions 14
C 38 x 14
MXZ-3B30NA
2-zone combinations wi at NA
A 12 x least one unit s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
9 + 24 14
3-zone combinations wi 1-MAC-A455JP-E
all units s12K
All other rated 3-zone NA
comb
MXZ-4B36NA
2-zone combinations wi at NA
A 12 x least one un it s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
6 + 24 14
1-MAC-A456JP-E D 38 x
9 + 24 14
3-zone combinations wi at NA
least two units s12K
3-zone combinations wi 1-MAC-A454JP-E
two units15K
6+6+24 or 6+9+24 1-MAC-A456JP-E
9+9+24 1-MAC-A456JP-E
4-zone combinations wi at 1-MAC-A455JP-E
least three units s12K
6+6+15+15 1-MAC-A454JP-E
6+6+15+15 1-MAC-A454JP-E
Note When using the Pu-A24BA PCA-A24KA or PEAD-A24AA two port adapter will be needed 1-MAC-A456JP-E (12 x 58) A port or 1-PACshySG76RJ-E (38 x 58) B C and D ports and 1-PAC493PI (14 x 38)
28 JMITSUBISHI ELECTRIC
6+6+246+9+24 6+12+249+9+24 9+12+24 or 12+12+24
6+15+24 6+18+24 9+15+249+18+24 12+15+24 or 12+18+24
15+15+24 15+18+24 or 18+18+24
15+24+24 or 18+24+24
Combinations of 4 or more zones
1-PAC-SG76RJ-E
See notes for application below
2
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
See notes for application below
PORT A =38 gas x 14 liquid
PORT B =38 gas x 14 liquid
PORT C =38 gas x 14 liquid
PORT A =38 gas x 14 liquid
PORT B = 38 gas x 14 liquid
PORT C = 38 gas x 14 liquid
PORT D =38 gas x 14 liquid
PORT E =12 gas x 14 liquid
Notes for application bull Check the lineset sizes for your indoor selected models bull Select the branch box or boxes needed for your application bull Compare indoor unit lineset sizes as compared to branch
box sizes bull Connect 15K + indoor units to the larger port on the
(PAC-AKA51 BC) bull Adapt lineset size with appropriate port adapter from
above list bull When using the PU-A24BA or PEAD-A24AA two port
adapter will be needed 1-MAC-A456JP-E (12 x 58) or 1-PAC-SG76RJ-E (38 x 58) and 1-PAC493PI (14 x 38)
-fv
~ DIAMONDBACKtrade
~) BV-Series Ball Valves Model numbers
BV14FFSI BV38FFSI
LISTED 891N REFRIGERANT
BV12FFSI VALVE bull Engineered for Mini-split andBV58FFSI
Multi-split HVAC Units bull Size available 14 38 12 58
bull Full Port Designbull Fully factory assembled bull Furnace brazed and pressure tested bull 700 PSIG Rated bull Each ball valve is equipped with Schraderreg Valve
for refrigerant service bull R-410A Compatible bull Design working pressure 700 PSIG bull Temperature range bull Flare Connections
-40 0 F to +3250 F (-400 C to + 1490
C) bull Forged brass body and seal cap bull Teflonreg seals and gaskets (no synthetic a-rings) bull Seal cap design permits valve operation without
removal of seal cap bull Suitable for use with R-11 R-22 R-123 R-125
R-134A R-236FA R-4202A R-402B R-404A R-407C R-410A R-500 R-502 and R-507
bull One year limited materials and workmanship
Part Number SAE Flare
A B C 0 E F
BV14FFSI 14 619 260 180 122 142 110
BV38FFSI 38 630 267 180 122 142 110
BV12FFSI 12 651 267 180 122 142 110
BV58FFSI 58 664 267 180 128 142 110
Ball valves come With an insulation piece warranty on Ball Valves
~ DIAMONDBACKtrade
~) Platform Stands
Lift the Mitsubishi Electric Comfort Solution
outdoor unit to new heights with our Diamondback Platform Stands
bull Easy to install
bull Available for all sizes of Mr Slim outdoor units
bull Color matched to the outdoor units
Model Number DSD-400N
L 15-34 x W 3-14 x H 3-14
r
)MITSUBISHI ELECTRIC 29
~ DIAMONDBACKtrade LINESETS
~~
Twin-Tube Lineset Insulation Design
bull Balanced outside diameter for uniform coiluncoil position stability
bull Minimum 12 insulation thickness on both tubes Diamondback Advantages include the following features
bull Quick efficient and economical field installation using factory applied Twin Tube insulation and flare connections with flare nuts mounted
bull Correct lengths for reducing waste and time
bull Quality consistency and economy
bull All Diamondback Lineset tubing is tested in accordance with ASTM E243
Filter Boxes
FB Series filter boxes are available in compatible sizes for all Mr Slim horizontal ducted indoor units
FBL 1 filter boxes include 1 thick pleated MERV 8 filter(s) installed Filters are tested in accordance with ANSIASHRAE Standard 522 and Rated Class 2 under UL Standard 900
The cabinet is constructed of non-insulated 20 gauge G-60 galvanized
FBL1-1 FB Series Filter Box for SEZ-KD09NA
FBL1-2 FB Series Filter Box for SEZ-KD12KD15-NA
FBL1-3 FB Series Filter Box for SEZ-KD18NA
steel with foam gasket and provides an air-tight connection to indoor unit and access door Gasket material complies with UL 723 requirements
A screw-through cabinet design for secure attachment to indoor unit and return connection in rear is easily field-converted to bottom return
30 MITSUBISHI ELECTRIC
bull
bull
bull
bull
bull
bull
LINE-HIDE~ Put a professional finish on air-conditioning
installations with an easy-to-install modular
system that beautifies exteriors and
protects Linesets drainlines and wiring
Can be use it indoors too Meets UL94v-O for interior applications
Has snap-on covers and a full selection of couplings elbows T-joints caps and more for any application complex or simple
Offers high-quality PVC with UV inhibitors for outdoor service in all weather conditions
Can be painted with most house paints to match exterior decors
Is not just for HVAC Hide any exterior cabling piping or wiring
Available in four sizes 2-14 3 4 and 6 tubes
Download a brochure at wwwline-hidecom to find out more information
For more information on our CITY MULTI VRF product line visit our website at wwwmitsubishiprocom
_lIJrUlllln ~ ~IIII1 fInll l
~
l bull bull
JMITSUBISHI ELECTRIC 31
MSZ Wall-Mounted Indoor Units for MXZ Heat Pump Systems
Providing a wide range of cooling and heating capacities each wall-mounted indoor unit mounts high on a wall and connects to a branch box or the outdoor unit by a refrigerant line run via a 3 hole The MSZ units provide highly efficient solutions to cooling and heating needs and provide personalized comfort for the individual zones in which they are installed
MSZ units on MXZ systems include the following features bull Sleek flat panel design bull Hot-start technology bull Quiet operation bull i-seeM sensor technology (MSZ-FE0912NA models only) bull Enhanced filtration system (MSZ-FE0912NA models only) bull Wireless remote control (optional wired wall-mounted controller)
SLZ Ceiling-Recessed Indoor Units for MXZ Heat Pump Systems
The new SLZ-KA ceiling casette systems offer a wide air-flow pattern for better air distribution
offered to your customers Installation can be done in a hard ceiling (with a access panel for servicing) or placed into a 2x2 drop ceiling With a built-in drain lift mechanism for condensate
removal and a 4 ventilation air intake knockout option the SLZ is ready to handle a variety of installation needs
SLZ units on MXZ systems include the following features bull Wide air-flow pattern for better air distibution bull 4 ventillation air intake knockout bull Built-in condensate lift mechanism bull Wireless RedLlNKTM remote controller
SEZ Horizontal Ducted Indoor Units for MXZ Heat Pump Systems
SEZ ducted units can provide split air-conditioning system advantages with the added benefit of being concealed to provide virtually no visual footprint within the conditioned space other than a register and grille for the air to flow With the use of short run ductwork these units can provide comfort to a single room that needs air dispersed evenly throughout the space unusually shaped rooms and adjacent rooms
The SEZ unit on MXZ systems include the fOllvowin fatures _
g~e~~~~==Zl[bull Concealed design for short-run ductwork bull Quiet operation bull Built-in condensate lift mechanism
JMITSUBISHI ELECTRIC 19
s c t
I
N o J ro o ltro ~ ro ~
DIAMOND COMFORT MXZ MULTI-ZONE SYSTEMS MXZ-B Series multi-zone systems provide personalized comfort control and energy efficiency in up to eight rooms with only a single outdoor unit The MXZ-B Series system features include
bull Individual zone control bull Mix and match flexibility of indoor unit styles and combinations bull A wide range of indoor unit capacities that match the room size and requirements bull Flexible design options to tackle the most challenging multi-room installations bull Efficient systems including three systems [mxz series] that meet energy starltID and
federal tax credit requirements bull Simple quick and cost-effective installation keeps install costs down on new construction
and disruption to a minimum on renovations and refits
Efficiency and performance ratings depend on the number style and capacity of the indoor units installed with each Multi-Zone System
MXZ -2 B20 NA - 1 (2 1 ) MXZ -3 B24 NA (2 13 1) Ou tdoo r Unit Outdoor Uni t
MSZ-GE09NA Indoor Units
SEZ-KD12NA Indoor Unit
MSZ- GE06NA
~~~~li
(At least two indoor units MSZ-GE06NAIndoor Unit must be installed) Indoor Unit
(Two indoor units must be installed )
MXZ -3 B30 NA (2 1 3 1) Outdoor Unit
SEZ-KD12NA Indoor Unit
~~~i
(At least two indoor units MSZ-GE06NA must be installed)
Indoor Unit ~
MFZ- KD12NA Indoor Unit
MXZ-8B48NA (2 1-8 1) Outdoor Unit
(At least two indoor units
must be installed)
(At least two indoor units must be installed)
MFZ-KD09NA Indoor Units
MSZ-GE09NA Indoor Units
SEZ-KD12NA Indoor Unit
MSZ INDOOR UNIT
MSZ-FE18NA
PEAD HORIZONTAL -DUCTED INDOOR UNIT
PEAD-A24AA
MSZ INDOOR UNIT SEZ HORIZONTAL-DUCTED MSZ-FE18NA
INDOOR UNIT MFZ FLOOR-STANDING SEZ-KD18NA INDOOR UNIT
MFZ-KA12NA
20 AMITSUBISHI ELECTRIC
MULTI-ROOM MXZ-8 INVERTER HEAT PUMP R
Model Name Outdoor Unit MXZ-2B20NA-1 5 MXZ-3B24NA 6 MXZ-3B30NA MXZ-4B36NA 7
Indoor Unit
Cooling 1 Non-ductedl Ducted
Rated Capacity Btuh 1800020000 2200023600 28400127400 3540034400
Capacity Range Btuh 7800-20000 12600-25500 12600-28400 12600-36400
Total Input W 2190 (630-219QL 2460 (1000-2950) 3330 l1 000-3330) 3 940 (1 000-4020)
Heating at 4JO F 2 Non-ductedl Ducted
Rated Capacity Btuh 2200022000 2500024600 2860027600 3600034400
Capacity Range Btuh 8500-25500 11400-30600 11 400-36000 11400-43000
Total Input W 2620 (520-2620) 1900 (740-2600) 2220 (740-2820) 3100 (740-3940)
Heating at 1JO F 3 Non-ductedl Ducted
Rated Capacity Btuh 1250012500 1400014000 1600015100 2220020300
Rated Total Input W 13501430 13801570 21202 140 24302340
Maximum Capacity Btu h 1450014500 1880017000 1880018000 2460025400
Maximum Total Inl2ut W 15001590 21202230 21202140 33403450
Power Supply Phase Cycle Voltage 1-phase 60Hz 2081 230V 8
Voltage Indoor shy Outdoor S1 - S2 AC 2081 230V
Indoor shy Outdoor S2 - S3 DC12-24V
Outdoor Unit 4
MCA A 15 19
MOCP A 20
Fan Motor FLA 096 093
Compressor
Model (Type)
DC INVERTER-driven Twin Rotary
RLA 101 11 144
LRA 15
Airflow (CoolingHeating) CFM 14851 640 20681605 13651605 20682068
Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1
dB(A) 49 54 49 54
Sound Pressure Level at Heating 2
dB(A) 51 49 57
External Finish Color Munsell No 30Y 781 1
Dimensions
W In 33-116 35-716
D In 13 12-58
H In 27-1516 35-7116
Weight Lbs 130 150 153
Indoor Unit No of Units 2 23 23 234
Remote Controller Type Associated with the Indoor Unit
Refrigerant
Type R410A
Charge Lbs Oz 515 7 11 813
Oil Type (fl oz)
NE022 (237) NE022 (294)
Refrigerant Pipe Gas Side 00 In AB 38 A 12 BC 38 A 12 BCD 38
Liquid Side 00 In 14
Refrigerant Pipe Length Height Difference (Max) Ft 4933 9
Length (Max) Ft 164 (A+B) 230 (A+B+C) 230 (A+B+C+D)
Connection Method IndoorOutdoor FlaredlFlared
Compatible with the MSZ-A MSZ-GA MSZ-FD MSZ-FE MSZ-GE MFZ-KA and SEZ-KD series indoor units (PLA-18 amp PCA-24 on the MXZ-MXZ-3B PLA-24 amp PCA-24 on the MXZ-4B)
NOTES Test conditions are based on AHRI 210240 One indoor unit is turned off during low-speed testing under the new test conditions Systems actually exhibit higher energy efficiencies during normal operation
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F (35deg C) WB 75deg F (24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F (6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 600 F (160 C) Outdoor DB 17deg F (_80 C) WB 150 F (_90 C) 4 Refer to pages 12 and 13 for Indoor Unit specifications 5 Data from combination of two Indoor Units 9000 Btuh (non-ducted) or one 9000 Btuh and one 12000 Btuh (ducted) 6 Data from combination of two Indoor Units 6000 Btuh and one 9000 Btuh (non-ducted) or three 9000 Btuh (ducted) 7 Data from combination of four Indoor Units 9000 Btuh (non-ducted and ducted) 8 Indoor units receive power from outdoor units through field-supplied interconnected wiring 9 49 Applies to installations where the outdoor unit is installed below the indoor unit
Power factor equals 97 percent
Specifications are subject to change without notice
MULTI-ZONE ENERGY STAR AND TAX CREDIT SYSTEMS
Model Indoor Unit Combinations SEER HSPF
MXZ-2B20NA-1 2 x MSZ- GE09NA 18 8 9
MXZ- 3B24NA 2 x MSZ- GE06NA 1 x MSZshy GE09NA
17 5 9 3
MXZ- 3B24NA 2 x MSZ-GE06NA 1 x MSZ- GE12NA
17 5 93
For more details on all ENERGY STAR and tax credit systems go to wwwmitsubishicomfortcomtaxcredit
See page 25 for additional info on efficiency
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 21
MXZ-8B48NA THE ULTIMATE ZONING SOLUTION
The Mitsubishi Electric MXZ-S84SNA eight-zone unit As a member of the expanding MXZ-B Series of multi-zone systems the MXZ-8B outdoor unit incorporates branch boxes to connect up to eight indoor units MXZ- 8 B48 NA (2 1 - 8 1 )
Outd oor Uni t The INVERTER-driven compressor at the heart of the MXZ-8B -~-- shy
outdoor unit provides variable capacity control allowing the system to adjust to the specific demands of the interior space ~ as needed not the hard start and stop of a traditional system I[iDA Jinstalled in most US homes
The MXZ -8B48NA has only one port on the outdoor unit for two insulated refrigerant lines which run into the home or business to connect to a branch box or boxes From the branch box(es) gas and liquid refrigerant piping run to each of the indoor units The LEV in the branch box(es) controls the refrigerant flow as the load of each zone changes
Through the branch box(es) (the PAC-AKA31 BC three-port andor the PAC-AKA51 BC five-port) the system can connect from two indoor units up to eight indoor units depending on application requirements
The flexibility of the system doesnt stop there The MXZ-8B48NA has rated capacities of 48000 Btuh for cooling and 54000 Btuh for heating System operation however can range from a minimum 12000 Btuh to a maximum 54000 Btuh in cooling and a maximum of 60000 Btuh in heating This type of performance supports a large variety of applications
The MXZ-8B48NA allows for further flexibility because it supports a connected indoor unit capacity from 22 to 130 or 12000 Btuh to a maximum 70200 Btuh depending on diversity
Connectable Indoor Units General Features bull Four-ton outdoor unit can support up to
eight indoor units using branch boxes bull Wide variety of indoor unit styles
-=--_-=-----= - - J _ 1
including wall-mounted floor-standing MSZ-FE09 12 18NA MSZ-GE06 09 12 15 18 24NA ceiling-cassette ducted
bull Individual control up to eight (8) zones using wired or wireless controls
bull Advanced microprocessor control bull Auto restart following a power outage bull Self-check function offering SEZ-KD09 1215 18NA PEAD-A24AA
integrated diagnostics ~--- Jbull Limited warranty five years on parts and
defects and seven years on compressors
SLZ-KA09 1215NA MFZ-KA09 12 18NA
22 MITSUBISHI ELECTRIC LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
I
RMULTI-ROOM MXZ-8 INVERTER HEAT PUMP
Model Name Outdoor Unit MXZ-BB4BNA Cooling 1 Rated Capacity
Non-ducted Rated Total Input Ducted
Maximum Capacity
Rated CapacityHeating at
Rated Total InputIndoor Unit 4JO F 2 Non-
ductedDucted Maximum Capacity
Rated Capacity Heating at
Rated Total InputlJO F 3 Non-ductedDucted Maximum Capacity
Power Supply Phase Cycle Voltage
Indoor - Outdoor Sl - S2 Voltage
Indoor - Outdoor S2 - S3
MCA
Recommended FuseBreaker Size
Fan Motor
Compressor
Airflow (CoolingHeating)
Refrigerant Control
Outdoor Unit Sound Pressure Level at Cooling 1
Sound Pressure Level at Heating 2
External Finish Color
Dimensions
Weight
Total Capacity 22-130
Indoor Unit ModelQuantity
Remote Controller Type
Type
Refrigerant Charge
Oil
Gas Side OD Refrigerant Pipe
Liquid Side OD
Height Difference (Max)
Maximum Distance between (Outdoor unit and farthest indoor unit)
Refrigerant Pipe Length Maximum Pipe Length -Branch box to Indoor Unit
Total Maximum line length between Branch Box and All Connected Indoor Units
Total Length (Max)
Connection Method IndoorOutdoor
Includes both branch boxes if there are two
Branch Boxes (At least one branch box required)
Btuh
W
Btuh
Btuh
W
Btuh
Btuh
W
Btuh
A
A
Type x Quantity
Motor Output (kW)
Model (Type)
Motor Output (kW)
CFM
dB(A)
dB(A)
W In
D In
H In
Lbs
Btuh
Lbs Oz
Type (fl oz)
In
In
Ft
Ft
Ft
Ft
Ft
4800048000
57806470
54000
5400054000
48205270
60000
3300034700
29503390
3660036550
1 Phase 60Hz 208 230V
AC 208-230V
DC12-24V
32
40
Propeller x 2
0086 + 0086
DC INVERTER-driven Scroll
29
3530
Linear Expansion Valve
54
55
Munsell No 3Y 78 11
37-716
13+1-3 16
53-3 16
278
12000 - 70200
600 - 24000 2-8
Associated with Indoor Unit Model
R410A
18 112
FV50S (73)
58
38
6698 4
230
49
197
377
FlaredFlared
Compatible with the MSZ-A MSZ-FO MSZ-FE MSZ-GE MFZ-KA SEZ-KD PLA and PEAD series indoor units
NOTES Test conditions are based on AHRI 210240 One indoor unit is turned off during low-speed testing under the new test conditions Systems actually exhibit higher energy efficiencies during normal operation
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F (35deg C) WB 75deg F (24deg C)
2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 4]0 F (8deg C) WB 43deg F (6deg C)
3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 17deg F (-8deg C) WB 15deg F(-9deg C)
4 66 applies to installations when the outdoor unit is installed below the indoor unit
Power factor equals 97 percent
Specifications are subject to change without notice
Note Maximum installed capacity is the maximum total of all connected indoor units NOT the maximum capacity produced
Only a single Lineset is needed from the outdoor unit to branch box
See page 25 for MXZ-B information on efficiency
Required Branch Boxes for MXZ-SB4BNA (Maximum of 2 branch boxes can be connected to one outdoor unit requires joint MSDD-50AR-E or MSDD-50BR-E)
s c d N o J ro Vl
0 ro n 3i n OJ d o J U)
PAC-AKA51 BC Branch Box
PAC-AKA31 BC Branch Box LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 23
MSZ WALL-MOUNTED INDOOR UNITS (FOR MXZ-8 OUTDOOR UNITS)
R
(MSZ-GE12NA MODEL SHOWN)
-000 IIIIIII 9000 9000 12000 12000 14000 17200
Heating at 4r Rated Capacity Btuh 7200 10900 10900 14400 13600 18000 21600
F2 Power Supply I Phase Cycle Voltage J -phase 60Hz 208 230V 3
Iindoor Outdoor S1 S2 AC 208 230V
Iindoor Outdoor S2 S3 DC12-24V Voltage
Iindoor Remote vomr Iller Wireless Type (Optional Wired vomroller DC 12V)
IMCA A 10 IFan Motor FLA 076
DRY 162-226shy145-170shy
162-226shy205-272shy 230-275shy
Airflow at Cooling (CFM)
145-170-237-321-399 339-381
237 -321shy381-410
335-420shy 339-420shy(Quiet-Lo-Med-Hishy 399 533 533 Super Hi or Lo-Med-
WET 144-202shy109-134shy
144-202shy170-237shy 194-240shy
Fan Hi-Powerful)1 (CFM)
109-134-201-286-364 307-343
201-286shy350-367
300-385shy 304-385shy364 498 498
Airflow at Heating 145-170shy 145-170shy 145-170shy 205-247shy 230-275shy
(Quiet-Lo-Med-Hi- WET 233-321shy 237-321shy
166-240shy237-321shy
166-240shy304-367shy 339-431shy
Super Hi or Lo-Medshy (CFM) 406 406
367 -381 406
399-420 463 512
Hi-Powerful) 2 Sound Pressure Level at Cooling
19-22-30shy 26-32-38shy 28-33-38shy(Quiet-Lo-Med-Hi-Super Hi or Loshy dB(A) 19-22-30-37 -43 22-31-39-42
37-45 22-33-43-45
44-49 44-49Med-Hi-Powerful) 1
Sound Pressure Level at Heating 19-22-30shy 26-30-35shy 28-33-38shy
(Quiet-Lo-Med-Hi-Super Hi or Loshy dB(A) 19-22-30-37 -43 22-31-40-42 37-43
22-23-43-44 40-46 43-48
Med-Hi-Powerful) 2
I External Finish Color Munsell No 10Y 92 02
IWln 31 middot716
Dimension Unit 10 In 9 18 10-18 9middot18 10-18 9-18
IH In 11-58
I Weight Unit ILbs 22 27 22 27 22 I Field Drainpipe ~D lin 58 Remote Con-
Type Wireless Remote (Optional Wired Controller) troller
ITvpe B41QA Refrigerant ~s$ideOD lin 38 Pipe I Liquid Side 00 In 14
Connection IndoorOutdoor FlaredFlared
Method
1~
II 18000 22500
21600 27600
388-469shy 38$-469shy628-738 628-738
347-420shy 347-420shy562-661 562-661
388-469shy 388-469shy628-738 628-738
34-41-49-53 34-41-49-53
32-41-49-52 32-41-49-52
43-516
9-38
12-1316 37
58 38
MXZ-2B20NA is also compatible with the MSZ-A and MSZ-FD series indoor units NOTES Test conditions are based on AHRI 210240
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F(6deg C) 3 Indoor units receive power from outdoor units through field-supplied wiring
Specifications are subject to change without notice LIMITED WARRANTY Seven-year warranty on compressor Five-year warranty on parts For data on specific indoor unit combinations see page 21
SEZ DUCTED INDOOR UNIT (FOR MXZ-8 OUTDOOR UNITS)
I
Notes 1 Cooling-Indoor DS 80deg F(267deg C) WS 67deg F(194deg C) Outdoor DS 95deg F (35deg C) WS 75deg F(239deg C)
2 Heating-Indoor DS 70deg F(211 deg C) WS 60deg F(156deg C) Outdoor DS 47deg F (83deg C) WS 43deg F(61 deg C)
3 External static pressure is factory set to 006 WGAdjustable via the
1---------t---+-----L-------------1~---__I PAR-21MAA
1--_____----__________+-____---L____----~_____________1 4 Indoor units receive power
jE~~~~-------------r----1-----~-~~~~~~~~-----___1 from outdoor units through fieldsupplied interconnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven-year warranty on compressor Five-year
1---------------------+---+------------------------1 warranty on parts
~--__I_~----------+-------~l----------I For data on specific indoor unit combinations see page 21 - 23
I--~------+~-----------~----------r_------------I
- Reference page 17 for SEZ static performance curves
24 MITSUBISHI ELECTRIC
25-30-35-40 26-31-36-41 35-38-42-46
25-30-35-40 28-31-36-41 35-38-42-47
MFZ FLOORLOW WALL INDOOR UNIT (FOR middotMXZ-8 OUTDOOR UNITS)
------shy
-==
Airflow at Heating (CFM) 177-198-219-332 184-201-219-335 261-275-297-434
Voltage
Fan
Airflow at Cooling (Lo-Med-Hi-Super Hi)1
169-205-251-314 251-279-325-394
163-197-241-303 170-207-252-309 241-269-313-379
(Lo-Med-Hi-Super Hi) 2
SLZ CEILING-RECESSED INDOOR UNIT (FOR MXZ-8 OUTDOOR UNITS) EFFICIENCY RATINGS
Voltage
Fan
Galvanized-steel SheetsMunsell 64Y 89 04
Refrigerant Pipe
Model Indoor Unit Type SEER HSPF
MXZ-2B20NA-1
Non-dueted 18 89
Dueted and Non-dueted 1675 87
Dueted 155 85
MXZ-2B20NA-1 ENERGY STAR amp
TAX CREDIT 2 x MSZ-GE09NA 18 89
MXZ-3B24NA
lJon-dueted 175 93
Dueted and Non-dueted 1625 89
Dueted 150 85
MXZ-3B24NA ENERGY STAR amp
TAX CREDIT
2 x MSZ-GE06NA 1 x MSZ-GE09NA
175 93
MXZ-3B24NA ENERGY STAR amp
TAX CREDIT
2 x MSZ-GE06NA 1 x MSZ-GE12NA
175 93
MXZ-3B30NA
Non-dueted 175 105
Dueted and Non-dueted 16 100
Dueted 145 95
MXZ-4B36NA
Non-dueted 18 93
Dueted and Non-dueted 16 5 92
Dueted 150 9 0
MXZ-BB4BNA
Non-dueted 15 87
Dueted and Non-dueted 14B B8
Dueted 147 89
Connection IndoorOutdoor FlaredFlared
Method
Notes 1 Cooling-Indoor DB 80deg F(267deg C) WB 67deg F(194deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(239deg C) 2 Heating-Indoor DB 70deg F(21 1 deg C) WB 60deg F(156deg C) Outdoor DB 47deg F(83deg C) WB 43deg F(61 deg C) 3 Indoor units receive power from outdoor units through field supplied interconnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 25
Notes 1 Cooling-Indoor DB 80deg F(267deg C) WB 67deg F (194deg C) Outdoor DB 95deg F (35deg C)WB 75deg F (239deg C)
2 Heating-Indoor DB 70deg F(211deg C) WB 60deg F (156deg C) Outdoor DB 47 F (83deg C) WB 43deg F (61 deg C)
3 Indoor units receive power from outdoor units through field supplied interco(lnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven -year warranty on compressor Five-year warranty on parts
Presently there is no 1 1 system with the MFZ indoor unit
s c
N o J ro Vl
C ro n ~ n OJ t o J V)
M-SERIES RATING CONDITIONS
INDOOR INTAKE AIR TEMPERATURE
OUTDOOR INTAKE AIR TEMPERATURE
COOLING
MAXIMUM
95degF DB 71 degF WB (MU SUZ MXZ-2B20-13B243B304B36) 90degF DB 73degF WB (MUZY-GE MUZ-FE MUzy-D)
115degF DB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B24 3B304B368B48)
MINIMUM 67degF DB 57degF WB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B201 3B243B304B36)
14degF DB (MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B24 3B304B36) 23degF DB (MXZ-8B48) 6rF DB (MU)
MAXIMUM 80degF DB 6rF WB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B243B304B36)
75degF DB 65degF WB (MUZY-GE MUZY-GA24 MUZ-FE SUZ MXZ-2B20-1 3B243B304B36) 70degF DB (MXZ-8B48)
HEATING
MINIMUM 70degF DB 60degFWB (MUZ-GE MUZ-GA24 MUZ-D MUZ-FE SUZ MXZ-2B20-1 3B243B304B36)
-13degF DB -15degFWB (MUZ-FE) -4degF DB -5degF WB (SUZ MUZ-GE) 5degF DB 4degF WB (MUZ-GA24 MXZ-8B48NA) 6degF DB 5degF WB (MXZ-2B20-1 3B24 3B304B36) 14degF DB 13degFWB (MUZ-D)
MU units operate at intake air temperature down to 10deg Fwith the addition of an ICM-326HM-1 low temperature control
REFRIGERANT TUBING SETS
OPTIONAL ACCESSORIES
REFRIGERANT LINE LENGTH FLARE FLARE _INDOOR UNIT OUTDOOR UNIT
MS-A09WA MU-A09WA 35 MS-A12WA
65 MU-A12WA 35
MSY-GE09NA 65
MUY-GE09NA 40
MSY-GE12NA
65
MUY-GE12NA 65 40
MSY-GE15NA MUY-GE15NA 40
MSY-GE18NA
65
MUY-GE18NA 100 50
MSZ-GE09NA MUZ-GE09NA 65 40
MSZ-GE12NA MUZ-GE12NA 40
MSZ-GE15NA
65
MUZ-GE15NA 40
MSZ-GE18NA
65
MUZ-GE18NA 100 50
MSY-GE24NA MUY-GE24NA 100 50
MSZ-GE24NA MUZ-GE24NA 100 50
MSY-D30NA MUY-D30NA 100 50
MSZ-D30NA MUZ-D30NA 50
MSY-D36NA
100
MUY-D36NA 50
MSZ-D36NA
100
MUZ-D36NA 100 50
MSZ-FE09NA MUZ-FE09NA 40
MSZ-FE12NA
65
MUZ-FE12NA 40
MSZ-GE06091215NA MSZ-FE0912NA
65
MXZ-2B20NA-1 164 4933MFZ-KA0912NA SEZ-KD09 1215NA
MSZ-GE0609 121518NA MSZ-FE091218N MFZ-KA09 1218NA MXZ-3B24NA 164 4933 SEZ -KD09 12 15 18NA SLZ-KA09 12 15NA
MSZ-GE0609 121518NA MSZ-GA24NA MSZ-FE091218NA
MXZ-3B30NA 4933230MFZ-KA091218NA SEZ -KD09 121518NA SLZ-KA09 12 15NA
MSZ-GE0609121518NA MSZ-GE24NA MSZ-FE09 12 18NA
MXZ-4B36NA 230 4933MFZ-KA091218NA SEZ -KD09121518NA SLZ-KA09 12 15NA
MSZ-GE0609 12 15 18NA MSZ-GE24NA MSZ-FE09 12 18NA
MXZ-8B48NA 6698377MFZ-KA091218NA SEZ-KD09121518NA SLZ-KA09 12 15NA
PART NUMBER I USE WITH I DESCRIPTION
Port Adapters and Connection Pipes MAC-A454JP-E MXZ-Series Adapter 38 X12
MAC-A455JP-E MXZ-Series Adapter 12 X38
MAC-A456JP-E MXZ-Series Adapter 12 X58
MSDD-50AR-E MXZ-Series Branch Box Tee Distribution Pipe - Flare Connection between two branch boxes
MSDD-50BR-E MXZ-Series Branch Box Tee Distribution Pipe - Braze Connection between two branch boxes
PAC-493PI MXZ-Series Adapter 14 X38
PAC-SG76RJ-E MXZ-Series Adapter 38 X58
OPTIONAL ACCESSORIES CONTINUED ON NEXT PAGE
49 amp 66 applies to installations in which the outdoor unit is installed below indoor unit26 MITSUBISHI ELECTRIC
OPTIONAL ACCESSORIES (CONTINUED)
PART NUMBER USE WITH DESCRIPTION Control Options and Accessories
M21 JKO 307 M-Series Indoor Units Remote temperature sensor for M-Series indoor units
MAC-397IF-E
MAC-399IF-E
PAC-YU25HT
PAR-21 MM-G
M-Series INVERTER Units
M-Series INVERTER Units
SEZ-KD Indoor Units
Use with P-Series SEZ and for wired M-Series Controller
MA and contact terminal interface - Required to use PAR-21 MM wired wall mount controller with M-Series Systems
CMCN M-NET control adapter I Interface for Mr Slim M-Series MSYZ SEZ I MFZ
External Fan I Heater control relay adapter
Deluxe MA remote controller (Requires MAC-397IF-E for use with M-Series - MSYZ MFZ)
SEZ Wireless remote controller for SEZ units (Requires signal receiver PAR-SA9FA-E)PAR-FL32MA
PAR-SA9CA-E SEZ Wireless signal receiver for SEZ
3-pole disconnect switch 30A 600V turns off power between indoor and outdoor units shyM-SeriesTAZ-MS303
mounts in 2 X 4 utility box and requires standard single gang switch platecover - Low Ambient
ICM-326HM-2 M-Series Non-INVERTER units Low ambient head pressure controller MUZ-GE091215 IVIUZ-FE0912 SUZ-KD091215
Drain pan heaterMAC-640BH-U outdoor unit
MAC-641 BH-U MUZ-GE18 SUZ-KD18 outdoor unit Drain pan heater Filters
MAC-1415FT-E Anti-allergy enzyme filter
MAC-2300FT
MSZlMSY-D3036
Anti -allergy enzyme filter
MAC-308FT
MSYMSZ-GA24
MSZ-FD912 I FE0912 Platinum deodorizing filter
MAC-408FT-E Anti-allergy enzyme filter
MAC-415FT-E
M-Series Indoor Unit - GE09GE12GE15GE18
MFZ-KA Air Cleaning FilterAnti-Aliergy Enzyme Filter
MAC-418FT Anti-allergy enzyme filter
Filter Boxes
FBL1-1
MSZ- FD912 I FE091 2
FB Series Filter Box for SEZ-KD09NA Optional filter box with MERV 8 filters
FB Series Filter Box for SEZ-KD1215NAFBL1-2 Optional filter box with MERV 8 filters
and PEA-A 12M
FBL1-3 FB Series Filter Box for SEZ-KD18NA Optional filter box with MERV 8 filters
Pumps
SI1730-230 MSYZ - 30000 Btuh or greater Sauermann mini condensation pump 230V
S13100-115 MS-Series - non-INVERTER Sauermann mini condensation pump 115V
S13100-230 Sauermann mini condensation pump 230VMSYZ - Less than 30000 Btuh
Miscellaneous BRP-1 Bottom Return Plate for SEZ-KD09NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-2 Bottom Return Plate for SEZ-KD12KD15-NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-3 Bottom Return Plate for SEZ-KD18NA Converts low profile ducted indoor unit from rear return to bottom return
BV12FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderreglnsulated - 12
BV14FSI Use with any Mr Sl im multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 14
BV38FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 38
BV58FSI Use with any IVIr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 58
Condensing unit wall mounting brackets (set of 2) - 440 lb capacity painted steel NOTE CWMB1 IVIU and PU outdoor units Installer is responsible to select and provide suitable hardware and materials to insure proper
mount of bracket to wall
DSD-400N M-Series DiamondBacktrade Platform Stands MUZ-GE18 I MUZ(y)-03036 I
MAC-811DS Drain socket assemblySUZ-KA18
MAC-851DS MUZ-FD0912 Drain socket
MAC-855SG M-Series Air outlet guide
MAC-856SG M-Series Air outlet guide - MXZ-3B24 I 3B30 I 4B36 NA
MAC-860DS MUZ-GE091215 I MUZ-FE0912 Drain socket
MAC-889SG M-Series Air outlet guide- MXZ-2B20NA
MAC-S99SG M-Series Air outlet guide
PAC-SG59SG-E IVIXZ-SB4SNA Air outlet guide (1 piece) I MXZ-SB48NA (Requires 2 pieces)
PAC-SG61 DS-E MXZ-8B4SNA Drain socket - connector
PAC-SG64DP-E MXZ-SB48NA Drain pan
RCMKP1CB lVI-Series Wireless Lockdown bracket for remote controller
lILTRILlTE1 All M-Series Condensing unit mounting pad 16 x 36 x 3
MITSUBISHI ELECTRIC 27
MXZ-8 Series Port Adapter chart Port Adapter Unit Port
Combinations Required Size
MXZ-2B20NA-1
2-zone combinations wi NA
A 38 x both units s12K 14
1-MAC-A454JP-E B 38 x
6+15 14
9+15 1-MAC-A454JP-E
MXZ-3B24NA
All rated 2-zone combina-NA
A 12 x tions 14
All rated 3-zone combina-NA
B 38 x tions 14
C 38 x 14
MXZ-3B30NA
2-zone combinations wi at NA
A 12 x least one unit s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
9 + 24 14
3-zone combinations wi 1-MAC-A455JP-E
all units s12K
All other rated 3-zone NA
comb
MXZ-4B36NA
2-zone combinations wi at NA
A 12 x least one un it s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
6 + 24 14
1-MAC-A456JP-E D 38 x
9 + 24 14
3-zone combinations wi at NA
least two units s12K
3-zone combinations wi 1-MAC-A454JP-E
two units15K
6+6+24 or 6+9+24 1-MAC-A456JP-E
9+9+24 1-MAC-A456JP-E
4-zone combinations wi at 1-MAC-A455JP-E
least three units s12K
6+6+15+15 1-MAC-A454JP-E
6+6+15+15 1-MAC-A454JP-E
Note When using the Pu-A24BA PCA-A24KA or PEAD-A24AA two port adapter will be needed 1-MAC-A456JP-E (12 x 58) A port or 1-PACshySG76RJ-E (38 x 58) B C and D ports and 1-PAC493PI (14 x 38)
28 JMITSUBISHI ELECTRIC
6+6+246+9+24 6+12+249+9+24 9+12+24 or 12+12+24
6+15+24 6+18+24 9+15+249+18+24 12+15+24 or 12+18+24
15+15+24 15+18+24 or 18+18+24
15+24+24 or 18+24+24
Combinations of 4 or more zones
1-PAC-SG76RJ-E
See notes for application below
2
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
See notes for application below
PORT A =38 gas x 14 liquid
PORT B =38 gas x 14 liquid
PORT C =38 gas x 14 liquid
PORT A =38 gas x 14 liquid
PORT B = 38 gas x 14 liquid
PORT C = 38 gas x 14 liquid
PORT D =38 gas x 14 liquid
PORT E =12 gas x 14 liquid
Notes for application bull Check the lineset sizes for your indoor selected models bull Select the branch box or boxes needed for your application bull Compare indoor unit lineset sizes as compared to branch
box sizes bull Connect 15K + indoor units to the larger port on the
(PAC-AKA51 BC) bull Adapt lineset size with appropriate port adapter from
above list bull When using the PU-A24BA or PEAD-A24AA two port
adapter will be needed 1-MAC-A456JP-E (12 x 58) or 1-PAC-SG76RJ-E (38 x 58) and 1-PAC493PI (14 x 38)
-fv
~ DIAMONDBACKtrade
~) BV-Series Ball Valves Model numbers
BV14FFSI BV38FFSI
LISTED 891N REFRIGERANT
BV12FFSI VALVE bull Engineered for Mini-split andBV58FFSI
Multi-split HVAC Units bull Size available 14 38 12 58
bull Full Port Designbull Fully factory assembled bull Furnace brazed and pressure tested bull 700 PSIG Rated bull Each ball valve is equipped with Schraderreg Valve
for refrigerant service bull R-410A Compatible bull Design working pressure 700 PSIG bull Temperature range bull Flare Connections
-40 0 F to +3250 F (-400 C to + 1490
C) bull Forged brass body and seal cap bull Teflonreg seals and gaskets (no synthetic a-rings) bull Seal cap design permits valve operation without
removal of seal cap bull Suitable for use with R-11 R-22 R-123 R-125
R-134A R-236FA R-4202A R-402B R-404A R-407C R-410A R-500 R-502 and R-507
bull One year limited materials and workmanship
Part Number SAE Flare
A B C 0 E F
BV14FFSI 14 619 260 180 122 142 110
BV38FFSI 38 630 267 180 122 142 110
BV12FFSI 12 651 267 180 122 142 110
BV58FFSI 58 664 267 180 128 142 110
Ball valves come With an insulation piece warranty on Ball Valves
~ DIAMONDBACKtrade
~) Platform Stands
Lift the Mitsubishi Electric Comfort Solution
outdoor unit to new heights with our Diamondback Platform Stands
bull Easy to install
bull Available for all sizes of Mr Slim outdoor units
bull Color matched to the outdoor units
Model Number DSD-400N
L 15-34 x W 3-14 x H 3-14
r
)MITSUBISHI ELECTRIC 29
~ DIAMONDBACKtrade LINESETS
~~
Twin-Tube Lineset Insulation Design
bull Balanced outside diameter for uniform coiluncoil position stability
bull Minimum 12 insulation thickness on both tubes Diamondback Advantages include the following features
bull Quick efficient and economical field installation using factory applied Twin Tube insulation and flare connections with flare nuts mounted
bull Correct lengths for reducing waste and time
bull Quality consistency and economy
bull All Diamondback Lineset tubing is tested in accordance with ASTM E243
Filter Boxes
FB Series filter boxes are available in compatible sizes for all Mr Slim horizontal ducted indoor units
FBL 1 filter boxes include 1 thick pleated MERV 8 filter(s) installed Filters are tested in accordance with ANSIASHRAE Standard 522 and Rated Class 2 under UL Standard 900
The cabinet is constructed of non-insulated 20 gauge G-60 galvanized
FBL1-1 FB Series Filter Box for SEZ-KD09NA
FBL1-2 FB Series Filter Box for SEZ-KD12KD15-NA
FBL1-3 FB Series Filter Box for SEZ-KD18NA
steel with foam gasket and provides an air-tight connection to indoor unit and access door Gasket material complies with UL 723 requirements
A screw-through cabinet design for secure attachment to indoor unit and return connection in rear is easily field-converted to bottom return
30 MITSUBISHI ELECTRIC
bull
bull
bull
bull
bull
bull
LINE-HIDE~ Put a professional finish on air-conditioning
installations with an easy-to-install modular
system that beautifies exteriors and
protects Linesets drainlines and wiring
Can be use it indoors too Meets UL94v-O for interior applications
Has snap-on covers and a full selection of couplings elbows T-joints caps and more for any application complex or simple
Offers high-quality PVC with UV inhibitors for outdoor service in all weather conditions
Can be painted with most house paints to match exterior decors
Is not just for HVAC Hide any exterior cabling piping or wiring
Available in four sizes 2-14 3 4 and 6 tubes
Download a brochure at wwwline-hidecom to find out more information
For more information on our CITY MULTI VRF product line visit our website at wwwmitsubishiprocom
_lIJrUlllln ~ ~IIII1 fInll l
~
l bull bull
JMITSUBISHI ELECTRIC 31
DIAMOND COMFORT MXZ MULTI-ZONE SYSTEMS MXZ-B Series multi-zone systems provide personalized comfort control and energy efficiency in up to eight rooms with only a single outdoor unit The MXZ-B Series system features include
bull Individual zone control bull Mix and match flexibility of indoor unit styles and combinations bull A wide range of indoor unit capacities that match the room size and requirements bull Flexible design options to tackle the most challenging multi-room installations bull Efficient systems including three systems [mxz series] that meet energy starltID and
federal tax credit requirements bull Simple quick and cost-effective installation keeps install costs down on new construction
and disruption to a minimum on renovations and refits
Efficiency and performance ratings depend on the number style and capacity of the indoor units installed with each Multi-Zone System
MXZ -2 B20 NA - 1 (2 1 ) MXZ -3 B24 NA (2 13 1) Ou tdoo r Unit Outdoor Uni t
MSZ-GE09NA Indoor Units
SEZ-KD12NA Indoor Unit
MSZ- GE06NA
~~~~li
(At least two indoor units MSZ-GE06NAIndoor Unit must be installed) Indoor Unit
(Two indoor units must be installed )
MXZ -3 B30 NA (2 1 3 1) Outdoor Unit
SEZ-KD12NA Indoor Unit
~~~i
(At least two indoor units MSZ-GE06NA must be installed)
Indoor Unit ~
MFZ- KD12NA Indoor Unit
MXZ-8B48NA (2 1-8 1) Outdoor Unit
(At least two indoor units
must be installed)
(At least two indoor units must be installed)
MFZ-KD09NA Indoor Units
MSZ-GE09NA Indoor Units
SEZ-KD12NA Indoor Unit
MSZ INDOOR UNIT
MSZ-FE18NA
PEAD HORIZONTAL -DUCTED INDOOR UNIT
PEAD-A24AA
MSZ INDOOR UNIT SEZ HORIZONTAL-DUCTED MSZ-FE18NA
INDOOR UNIT MFZ FLOOR-STANDING SEZ-KD18NA INDOOR UNIT
MFZ-KA12NA
20 AMITSUBISHI ELECTRIC
MULTI-ROOM MXZ-8 INVERTER HEAT PUMP R
Model Name Outdoor Unit MXZ-2B20NA-1 5 MXZ-3B24NA 6 MXZ-3B30NA MXZ-4B36NA 7
Indoor Unit
Cooling 1 Non-ductedl Ducted
Rated Capacity Btuh 1800020000 2200023600 28400127400 3540034400
Capacity Range Btuh 7800-20000 12600-25500 12600-28400 12600-36400
Total Input W 2190 (630-219QL 2460 (1000-2950) 3330 l1 000-3330) 3 940 (1 000-4020)
Heating at 4JO F 2 Non-ductedl Ducted
Rated Capacity Btuh 2200022000 2500024600 2860027600 3600034400
Capacity Range Btuh 8500-25500 11400-30600 11 400-36000 11400-43000
Total Input W 2620 (520-2620) 1900 (740-2600) 2220 (740-2820) 3100 (740-3940)
Heating at 1JO F 3 Non-ductedl Ducted
Rated Capacity Btuh 1250012500 1400014000 1600015100 2220020300
Rated Total Input W 13501430 13801570 21202 140 24302340
Maximum Capacity Btu h 1450014500 1880017000 1880018000 2460025400
Maximum Total Inl2ut W 15001590 21202230 21202140 33403450
Power Supply Phase Cycle Voltage 1-phase 60Hz 2081 230V 8
Voltage Indoor shy Outdoor S1 - S2 AC 2081 230V
Indoor shy Outdoor S2 - S3 DC12-24V
Outdoor Unit 4
MCA A 15 19
MOCP A 20
Fan Motor FLA 096 093
Compressor
Model (Type)
DC INVERTER-driven Twin Rotary
RLA 101 11 144
LRA 15
Airflow (CoolingHeating) CFM 14851 640 20681605 13651605 20682068
Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1
dB(A) 49 54 49 54
Sound Pressure Level at Heating 2
dB(A) 51 49 57
External Finish Color Munsell No 30Y 781 1
Dimensions
W In 33-116 35-716
D In 13 12-58
H In 27-1516 35-7116
Weight Lbs 130 150 153
Indoor Unit No of Units 2 23 23 234
Remote Controller Type Associated with the Indoor Unit
Refrigerant
Type R410A
Charge Lbs Oz 515 7 11 813
Oil Type (fl oz)
NE022 (237) NE022 (294)
Refrigerant Pipe Gas Side 00 In AB 38 A 12 BC 38 A 12 BCD 38
Liquid Side 00 In 14
Refrigerant Pipe Length Height Difference (Max) Ft 4933 9
Length (Max) Ft 164 (A+B) 230 (A+B+C) 230 (A+B+C+D)
Connection Method IndoorOutdoor FlaredlFlared
Compatible with the MSZ-A MSZ-GA MSZ-FD MSZ-FE MSZ-GE MFZ-KA and SEZ-KD series indoor units (PLA-18 amp PCA-24 on the MXZ-MXZ-3B PLA-24 amp PCA-24 on the MXZ-4B)
NOTES Test conditions are based on AHRI 210240 One indoor unit is turned off during low-speed testing under the new test conditions Systems actually exhibit higher energy efficiencies during normal operation
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F (35deg C) WB 75deg F (24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F (6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 600 F (160 C) Outdoor DB 17deg F (_80 C) WB 150 F (_90 C) 4 Refer to pages 12 and 13 for Indoor Unit specifications 5 Data from combination of two Indoor Units 9000 Btuh (non-ducted) or one 9000 Btuh and one 12000 Btuh (ducted) 6 Data from combination of two Indoor Units 6000 Btuh and one 9000 Btuh (non-ducted) or three 9000 Btuh (ducted) 7 Data from combination of four Indoor Units 9000 Btuh (non-ducted and ducted) 8 Indoor units receive power from outdoor units through field-supplied interconnected wiring 9 49 Applies to installations where the outdoor unit is installed below the indoor unit
Power factor equals 97 percent
Specifications are subject to change without notice
MULTI-ZONE ENERGY STAR AND TAX CREDIT SYSTEMS
Model Indoor Unit Combinations SEER HSPF
MXZ-2B20NA-1 2 x MSZ- GE09NA 18 8 9
MXZ- 3B24NA 2 x MSZ- GE06NA 1 x MSZshy GE09NA
17 5 9 3
MXZ- 3B24NA 2 x MSZ-GE06NA 1 x MSZ- GE12NA
17 5 93
For more details on all ENERGY STAR and tax credit systems go to wwwmitsubishicomfortcomtaxcredit
See page 25 for additional info on efficiency
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 21
MXZ-8B48NA THE ULTIMATE ZONING SOLUTION
The Mitsubishi Electric MXZ-S84SNA eight-zone unit As a member of the expanding MXZ-B Series of multi-zone systems the MXZ-8B outdoor unit incorporates branch boxes to connect up to eight indoor units MXZ- 8 B48 NA (2 1 - 8 1 )
Outd oor Uni t The INVERTER-driven compressor at the heart of the MXZ-8B -~-- shy
outdoor unit provides variable capacity control allowing the system to adjust to the specific demands of the interior space ~ as needed not the hard start and stop of a traditional system I[iDA Jinstalled in most US homes
The MXZ -8B48NA has only one port on the outdoor unit for two insulated refrigerant lines which run into the home or business to connect to a branch box or boxes From the branch box(es) gas and liquid refrigerant piping run to each of the indoor units The LEV in the branch box(es) controls the refrigerant flow as the load of each zone changes
Through the branch box(es) (the PAC-AKA31 BC three-port andor the PAC-AKA51 BC five-port) the system can connect from two indoor units up to eight indoor units depending on application requirements
The flexibility of the system doesnt stop there The MXZ-8B48NA has rated capacities of 48000 Btuh for cooling and 54000 Btuh for heating System operation however can range from a minimum 12000 Btuh to a maximum 54000 Btuh in cooling and a maximum of 60000 Btuh in heating This type of performance supports a large variety of applications
The MXZ-8B48NA allows for further flexibility because it supports a connected indoor unit capacity from 22 to 130 or 12000 Btuh to a maximum 70200 Btuh depending on diversity
Connectable Indoor Units General Features bull Four-ton outdoor unit can support up to
eight indoor units using branch boxes bull Wide variety of indoor unit styles
-=--_-=-----= - - J _ 1
including wall-mounted floor-standing MSZ-FE09 12 18NA MSZ-GE06 09 12 15 18 24NA ceiling-cassette ducted
bull Individual control up to eight (8) zones using wired or wireless controls
bull Advanced microprocessor control bull Auto restart following a power outage bull Self-check function offering SEZ-KD09 1215 18NA PEAD-A24AA
integrated diagnostics ~--- Jbull Limited warranty five years on parts and
defects and seven years on compressors
SLZ-KA09 1215NA MFZ-KA09 12 18NA
22 MITSUBISHI ELECTRIC LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
I
RMULTI-ROOM MXZ-8 INVERTER HEAT PUMP
Model Name Outdoor Unit MXZ-BB4BNA Cooling 1 Rated Capacity
Non-ducted Rated Total Input Ducted
Maximum Capacity
Rated CapacityHeating at
Rated Total InputIndoor Unit 4JO F 2 Non-
ductedDucted Maximum Capacity
Rated Capacity Heating at
Rated Total InputlJO F 3 Non-ductedDucted Maximum Capacity
Power Supply Phase Cycle Voltage
Indoor - Outdoor Sl - S2 Voltage
Indoor - Outdoor S2 - S3
MCA
Recommended FuseBreaker Size
Fan Motor
Compressor
Airflow (CoolingHeating)
Refrigerant Control
Outdoor Unit Sound Pressure Level at Cooling 1
Sound Pressure Level at Heating 2
External Finish Color
Dimensions
Weight
Total Capacity 22-130
Indoor Unit ModelQuantity
Remote Controller Type
Type
Refrigerant Charge
Oil
Gas Side OD Refrigerant Pipe
Liquid Side OD
Height Difference (Max)
Maximum Distance between (Outdoor unit and farthest indoor unit)
Refrigerant Pipe Length Maximum Pipe Length -Branch box to Indoor Unit
Total Maximum line length between Branch Box and All Connected Indoor Units
Total Length (Max)
Connection Method IndoorOutdoor
Includes both branch boxes if there are two
Branch Boxes (At least one branch box required)
Btuh
W
Btuh
Btuh
W
Btuh
Btuh
W
Btuh
A
A
Type x Quantity
Motor Output (kW)
Model (Type)
Motor Output (kW)
CFM
dB(A)
dB(A)
W In
D In
H In
Lbs
Btuh
Lbs Oz
Type (fl oz)
In
In
Ft
Ft
Ft
Ft
Ft
4800048000
57806470
54000
5400054000
48205270
60000
3300034700
29503390
3660036550
1 Phase 60Hz 208 230V
AC 208-230V
DC12-24V
32
40
Propeller x 2
0086 + 0086
DC INVERTER-driven Scroll
29
3530
Linear Expansion Valve
54
55
Munsell No 3Y 78 11
37-716
13+1-3 16
53-3 16
278
12000 - 70200
600 - 24000 2-8
Associated with Indoor Unit Model
R410A
18 112
FV50S (73)
58
38
6698 4
230
49
197
377
FlaredFlared
Compatible with the MSZ-A MSZ-FO MSZ-FE MSZ-GE MFZ-KA SEZ-KD PLA and PEAD series indoor units
NOTES Test conditions are based on AHRI 210240 One indoor unit is turned off during low-speed testing under the new test conditions Systems actually exhibit higher energy efficiencies during normal operation
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F (35deg C) WB 75deg F (24deg C)
2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 4]0 F (8deg C) WB 43deg F (6deg C)
3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 17deg F (-8deg C) WB 15deg F(-9deg C)
4 66 applies to installations when the outdoor unit is installed below the indoor unit
Power factor equals 97 percent
Specifications are subject to change without notice
Note Maximum installed capacity is the maximum total of all connected indoor units NOT the maximum capacity produced
Only a single Lineset is needed from the outdoor unit to branch box
See page 25 for MXZ-B information on efficiency
Required Branch Boxes for MXZ-SB4BNA (Maximum of 2 branch boxes can be connected to one outdoor unit requires joint MSDD-50AR-E or MSDD-50BR-E)
s c d N o J ro Vl
0 ro n 3i n OJ d o J U)
PAC-AKA51 BC Branch Box
PAC-AKA31 BC Branch Box LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 23
MSZ WALL-MOUNTED INDOOR UNITS (FOR MXZ-8 OUTDOOR UNITS)
R
(MSZ-GE12NA MODEL SHOWN)
-000 IIIIIII 9000 9000 12000 12000 14000 17200
Heating at 4r Rated Capacity Btuh 7200 10900 10900 14400 13600 18000 21600
F2 Power Supply I Phase Cycle Voltage J -phase 60Hz 208 230V 3
Iindoor Outdoor S1 S2 AC 208 230V
Iindoor Outdoor S2 S3 DC12-24V Voltage
Iindoor Remote vomr Iller Wireless Type (Optional Wired vomroller DC 12V)
IMCA A 10 IFan Motor FLA 076
DRY 162-226shy145-170shy
162-226shy205-272shy 230-275shy
Airflow at Cooling (CFM)
145-170-237-321-399 339-381
237 -321shy381-410
335-420shy 339-420shy(Quiet-Lo-Med-Hishy 399 533 533 Super Hi or Lo-Med-
WET 144-202shy109-134shy
144-202shy170-237shy 194-240shy
Fan Hi-Powerful)1 (CFM)
109-134-201-286-364 307-343
201-286shy350-367
300-385shy 304-385shy364 498 498
Airflow at Heating 145-170shy 145-170shy 145-170shy 205-247shy 230-275shy
(Quiet-Lo-Med-Hi- WET 233-321shy 237-321shy
166-240shy237-321shy
166-240shy304-367shy 339-431shy
Super Hi or Lo-Medshy (CFM) 406 406
367 -381 406
399-420 463 512
Hi-Powerful) 2 Sound Pressure Level at Cooling
19-22-30shy 26-32-38shy 28-33-38shy(Quiet-Lo-Med-Hi-Super Hi or Loshy dB(A) 19-22-30-37 -43 22-31-39-42
37-45 22-33-43-45
44-49 44-49Med-Hi-Powerful) 1
Sound Pressure Level at Heating 19-22-30shy 26-30-35shy 28-33-38shy
(Quiet-Lo-Med-Hi-Super Hi or Loshy dB(A) 19-22-30-37 -43 22-31-40-42 37-43
22-23-43-44 40-46 43-48
Med-Hi-Powerful) 2
I External Finish Color Munsell No 10Y 92 02
IWln 31 middot716
Dimension Unit 10 In 9 18 10-18 9middot18 10-18 9-18
IH In 11-58
I Weight Unit ILbs 22 27 22 27 22 I Field Drainpipe ~D lin 58 Remote Con-
Type Wireless Remote (Optional Wired Controller) troller
ITvpe B41QA Refrigerant ~s$ideOD lin 38 Pipe I Liquid Side 00 In 14
Connection IndoorOutdoor FlaredFlared
Method
1~
II 18000 22500
21600 27600
388-469shy 38$-469shy628-738 628-738
347-420shy 347-420shy562-661 562-661
388-469shy 388-469shy628-738 628-738
34-41-49-53 34-41-49-53
32-41-49-52 32-41-49-52
43-516
9-38
12-1316 37
58 38
MXZ-2B20NA is also compatible with the MSZ-A and MSZ-FD series indoor units NOTES Test conditions are based on AHRI 210240
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F(6deg C) 3 Indoor units receive power from outdoor units through field-supplied wiring
Specifications are subject to change without notice LIMITED WARRANTY Seven-year warranty on compressor Five-year warranty on parts For data on specific indoor unit combinations see page 21
SEZ DUCTED INDOOR UNIT (FOR MXZ-8 OUTDOOR UNITS)
I
Notes 1 Cooling-Indoor DS 80deg F(267deg C) WS 67deg F(194deg C) Outdoor DS 95deg F (35deg C) WS 75deg F(239deg C)
2 Heating-Indoor DS 70deg F(211 deg C) WS 60deg F(156deg C) Outdoor DS 47deg F (83deg C) WS 43deg F(61 deg C)
3 External static pressure is factory set to 006 WGAdjustable via the
1---------t---+-----L-------------1~---__I PAR-21MAA
1--_____----__________+-____---L____----~_____________1 4 Indoor units receive power
jE~~~~-------------r----1-----~-~~~~~~~~-----___1 from outdoor units through fieldsupplied interconnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven-year warranty on compressor Five-year
1---------------------+---+------------------------1 warranty on parts
~--__I_~----------+-------~l----------I For data on specific indoor unit combinations see page 21 - 23
I--~------+~-----------~----------r_------------I
- Reference page 17 for SEZ static performance curves
24 MITSUBISHI ELECTRIC
25-30-35-40 26-31-36-41 35-38-42-46
25-30-35-40 28-31-36-41 35-38-42-47
MFZ FLOORLOW WALL INDOOR UNIT (FOR middotMXZ-8 OUTDOOR UNITS)
------shy
-==
Airflow at Heating (CFM) 177-198-219-332 184-201-219-335 261-275-297-434
Voltage
Fan
Airflow at Cooling (Lo-Med-Hi-Super Hi)1
169-205-251-314 251-279-325-394
163-197-241-303 170-207-252-309 241-269-313-379
(Lo-Med-Hi-Super Hi) 2
SLZ CEILING-RECESSED INDOOR UNIT (FOR MXZ-8 OUTDOOR UNITS) EFFICIENCY RATINGS
Voltage
Fan
Galvanized-steel SheetsMunsell 64Y 89 04
Refrigerant Pipe
Model Indoor Unit Type SEER HSPF
MXZ-2B20NA-1
Non-dueted 18 89
Dueted and Non-dueted 1675 87
Dueted 155 85
MXZ-2B20NA-1 ENERGY STAR amp
TAX CREDIT 2 x MSZ-GE09NA 18 89
MXZ-3B24NA
lJon-dueted 175 93
Dueted and Non-dueted 1625 89
Dueted 150 85
MXZ-3B24NA ENERGY STAR amp
TAX CREDIT
2 x MSZ-GE06NA 1 x MSZ-GE09NA
175 93
MXZ-3B24NA ENERGY STAR amp
TAX CREDIT
2 x MSZ-GE06NA 1 x MSZ-GE12NA
175 93
MXZ-3B30NA
Non-dueted 175 105
Dueted and Non-dueted 16 100
Dueted 145 95
MXZ-4B36NA
Non-dueted 18 93
Dueted and Non-dueted 16 5 92
Dueted 150 9 0
MXZ-BB4BNA
Non-dueted 15 87
Dueted and Non-dueted 14B B8
Dueted 147 89
Connection IndoorOutdoor FlaredFlared
Method
Notes 1 Cooling-Indoor DB 80deg F(267deg C) WB 67deg F(194deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(239deg C) 2 Heating-Indoor DB 70deg F(21 1 deg C) WB 60deg F(156deg C) Outdoor DB 47deg F(83deg C) WB 43deg F(61 deg C) 3 Indoor units receive power from outdoor units through field supplied interconnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 25
Notes 1 Cooling-Indoor DB 80deg F(267deg C) WB 67deg F (194deg C) Outdoor DB 95deg F (35deg C)WB 75deg F (239deg C)
2 Heating-Indoor DB 70deg F(211deg C) WB 60deg F (156deg C) Outdoor DB 47 F (83deg C) WB 43deg F (61 deg C)
3 Indoor units receive power from outdoor units through field supplied interco(lnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven -year warranty on compressor Five-year warranty on parts
Presently there is no 1 1 system with the MFZ indoor unit
s c
N o J ro Vl
C ro n ~ n OJ t o J V)
M-SERIES RATING CONDITIONS
INDOOR INTAKE AIR TEMPERATURE
OUTDOOR INTAKE AIR TEMPERATURE
COOLING
MAXIMUM
95degF DB 71 degF WB (MU SUZ MXZ-2B20-13B243B304B36) 90degF DB 73degF WB (MUZY-GE MUZ-FE MUzy-D)
115degF DB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B24 3B304B368B48)
MINIMUM 67degF DB 57degF WB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B201 3B243B304B36)
14degF DB (MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B24 3B304B36) 23degF DB (MXZ-8B48) 6rF DB (MU)
MAXIMUM 80degF DB 6rF WB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B243B304B36)
75degF DB 65degF WB (MUZY-GE MUZY-GA24 MUZ-FE SUZ MXZ-2B20-1 3B243B304B36) 70degF DB (MXZ-8B48)
HEATING
MINIMUM 70degF DB 60degFWB (MUZ-GE MUZ-GA24 MUZ-D MUZ-FE SUZ MXZ-2B20-1 3B243B304B36)
-13degF DB -15degFWB (MUZ-FE) -4degF DB -5degF WB (SUZ MUZ-GE) 5degF DB 4degF WB (MUZ-GA24 MXZ-8B48NA) 6degF DB 5degF WB (MXZ-2B20-1 3B24 3B304B36) 14degF DB 13degFWB (MUZ-D)
MU units operate at intake air temperature down to 10deg Fwith the addition of an ICM-326HM-1 low temperature control
REFRIGERANT TUBING SETS
OPTIONAL ACCESSORIES
REFRIGERANT LINE LENGTH FLARE FLARE _INDOOR UNIT OUTDOOR UNIT
MS-A09WA MU-A09WA 35 MS-A12WA
65 MU-A12WA 35
MSY-GE09NA 65
MUY-GE09NA 40
MSY-GE12NA
65
MUY-GE12NA 65 40
MSY-GE15NA MUY-GE15NA 40
MSY-GE18NA
65
MUY-GE18NA 100 50
MSZ-GE09NA MUZ-GE09NA 65 40
MSZ-GE12NA MUZ-GE12NA 40
MSZ-GE15NA
65
MUZ-GE15NA 40
MSZ-GE18NA
65
MUZ-GE18NA 100 50
MSY-GE24NA MUY-GE24NA 100 50
MSZ-GE24NA MUZ-GE24NA 100 50
MSY-D30NA MUY-D30NA 100 50
MSZ-D30NA MUZ-D30NA 50
MSY-D36NA
100
MUY-D36NA 50
MSZ-D36NA
100
MUZ-D36NA 100 50
MSZ-FE09NA MUZ-FE09NA 40
MSZ-FE12NA
65
MUZ-FE12NA 40
MSZ-GE06091215NA MSZ-FE0912NA
65
MXZ-2B20NA-1 164 4933MFZ-KA0912NA SEZ-KD09 1215NA
MSZ-GE0609 121518NA MSZ-FE091218N MFZ-KA09 1218NA MXZ-3B24NA 164 4933 SEZ -KD09 12 15 18NA SLZ-KA09 12 15NA
MSZ-GE0609 121518NA MSZ-GA24NA MSZ-FE091218NA
MXZ-3B30NA 4933230MFZ-KA091218NA SEZ -KD09 121518NA SLZ-KA09 12 15NA
MSZ-GE0609121518NA MSZ-GE24NA MSZ-FE09 12 18NA
MXZ-4B36NA 230 4933MFZ-KA091218NA SEZ -KD09121518NA SLZ-KA09 12 15NA
MSZ-GE0609 12 15 18NA MSZ-GE24NA MSZ-FE09 12 18NA
MXZ-8B48NA 6698377MFZ-KA091218NA SEZ-KD09121518NA SLZ-KA09 12 15NA
PART NUMBER I USE WITH I DESCRIPTION
Port Adapters and Connection Pipes MAC-A454JP-E MXZ-Series Adapter 38 X12
MAC-A455JP-E MXZ-Series Adapter 12 X38
MAC-A456JP-E MXZ-Series Adapter 12 X58
MSDD-50AR-E MXZ-Series Branch Box Tee Distribution Pipe - Flare Connection between two branch boxes
MSDD-50BR-E MXZ-Series Branch Box Tee Distribution Pipe - Braze Connection between two branch boxes
PAC-493PI MXZ-Series Adapter 14 X38
PAC-SG76RJ-E MXZ-Series Adapter 38 X58
OPTIONAL ACCESSORIES CONTINUED ON NEXT PAGE
49 amp 66 applies to installations in which the outdoor unit is installed below indoor unit26 MITSUBISHI ELECTRIC
OPTIONAL ACCESSORIES (CONTINUED)
PART NUMBER USE WITH DESCRIPTION Control Options and Accessories
M21 JKO 307 M-Series Indoor Units Remote temperature sensor for M-Series indoor units
MAC-397IF-E
MAC-399IF-E
PAC-YU25HT
PAR-21 MM-G
M-Series INVERTER Units
M-Series INVERTER Units
SEZ-KD Indoor Units
Use with P-Series SEZ and for wired M-Series Controller
MA and contact terminal interface - Required to use PAR-21 MM wired wall mount controller with M-Series Systems
CMCN M-NET control adapter I Interface for Mr Slim M-Series MSYZ SEZ I MFZ
External Fan I Heater control relay adapter
Deluxe MA remote controller (Requires MAC-397IF-E for use with M-Series - MSYZ MFZ)
SEZ Wireless remote controller for SEZ units (Requires signal receiver PAR-SA9FA-E)PAR-FL32MA
PAR-SA9CA-E SEZ Wireless signal receiver for SEZ
3-pole disconnect switch 30A 600V turns off power between indoor and outdoor units shyM-SeriesTAZ-MS303
mounts in 2 X 4 utility box and requires standard single gang switch platecover - Low Ambient
ICM-326HM-2 M-Series Non-INVERTER units Low ambient head pressure controller MUZ-GE091215 IVIUZ-FE0912 SUZ-KD091215
Drain pan heaterMAC-640BH-U outdoor unit
MAC-641 BH-U MUZ-GE18 SUZ-KD18 outdoor unit Drain pan heater Filters
MAC-1415FT-E Anti-allergy enzyme filter
MAC-2300FT
MSZlMSY-D3036
Anti -allergy enzyme filter
MAC-308FT
MSYMSZ-GA24
MSZ-FD912 I FE0912 Platinum deodorizing filter
MAC-408FT-E Anti-allergy enzyme filter
MAC-415FT-E
M-Series Indoor Unit - GE09GE12GE15GE18
MFZ-KA Air Cleaning FilterAnti-Aliergy Enzyme Filter
MAC-418FT Anti-allergy enzyme filter
Filter Boxes
FBL1-1
MSZ- FD912 I FE091 2
FB Series Filter Box for SEZ-KD09NA Optional filter box with MERV 8 filters
FB Series Filter Box for SEZ-KD1215NAFBL1-2 Optional filter box with MERV 8 filters
and PEA-A 12M
FBL1-3 FB Series Filter Box for SEZ-KD18NA Optional filter box with MERV 8 filters
Pumps
SI1730-230 MSYZ - 30000 Btuh or greater Sauermann mini condensation pump 230V
S13100-115 MS-Series - non-INVERTER Sauermann mini condensation pump 115V
S13100-230 Sauermann mini condensation pump 230VMSYZ - Less than 30000 Btuh
Miscellaneous BRP-1 Bottom Return Plate for SEZ-KD09NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-2 Bottom Return Plate for SEZ-KD12KD15-NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-3 Bottom Return Plate for SEZ-KD18NA Converts low profile ducted indoor unit from rear return to bottom return
BV12FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderreglnsulated - 12
BV14FSI Use with any Mr Sl im multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 14
BV38FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 38
BV58FSI Use with any IVIr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 58
Condensing unit wall mounting brackets (set of 2) - 440 lb capacity painted steel NOTE CWMB1 IVIU and PU outdoor units Installer is responsible to select and provide suitable hardware and materials to insure proper
mount of bracket to wall
DSD-400N M-Series DiamondBacktrade Platform Stands MUZ-GE18 I MUZ(y)-03036 I
MAC-811DS Drain socket assemblySUZ-KA18
MAC-851DS MUZ-FD0912 Drain socket
MAC-855SG M-Series Air outlet guide
MAC-856SG M-Series Air outlet guide - MXZ-3B24 I 3B30 I 4B36 NA
MAC-860DS MUZ-GE091215 I MUZ-FE0912 Drain socket
MAC-889SG M-Series Air outlet guide- MXZ-2B20NA
MAC-S99SG M-Series Air outlet guide
PAC-SG59SG-E IVIXZ-SB4SNA Air outlet guide (1 piece) I MXZ-SB48NA (Requires 2 pieces)
PAC-SG61 DS-E MXZ-8B4SNA Drain socket - connector
PAC-SG64DP-E MXZ-SB48NA Drain pan
RCMKP1CB lVI-Series Wireless Lockdown bracket for remote controller
lILTRILlTE1 All M-Series Condensing unit mounting pad 16 x 36 x 3
MITSUBISHI ELECTRIC 27
MXZ-8 Series Port Adapter chart Port Adapter Unit Port
Combinations Required Size
MXZ-2B20NA-1
2-zone combinations wi NA
A 38 x both units s12K 14
1-MAC-A454JP-E B 38 x
6+15 14
9+15 1-MAC-A454JP-E
MXZ-3B24NA
All rated 2-zone combina-NA
A 12 x tions 14
All rated 3-zone combina-NA
B 38 x tions 14
C 38 x 14
MXZ-3B30NA
2-zone combinations wi at NA
A 12 x least one unit s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
9 + 24 14
3-zone combinations wi 1-MAC-A455JP-E
all units s12K
All other rated 3-zone NA
comb
MXZ-4B36NA
2-zone combinations wi at NA
A 12 x least one un it s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
6 + 24 14
1-MAC-A456JP-E D 38 x
9 + 24 14
3-zone combinations wi at NA
least two units s12K
3-zone combinations wi 1-MAC-A454JP-E
two units15K
6+6+24 or 6+9+24 1-MAC-A456JP-E
9+9+24 1-MAC-A456JP-E
4-zone combinations wi at 1-MAC-A455JP-E
least three units s12K
6+6+15+15 1-MAC-A454JP-E
6+6+15+15 1-MAC-A454JP-E
Note When using the Pu-A24BA PCA-A24KA or PEAD-A24AA two port adapter will be needed 1-MAC-A456JP-E (12 x 58) A port or 1-PACshySG76RJ-E (38 x 58) B C and D ports and 1-PAC493PI (14 x 38)
28 JMITSUBISHI ELECTRIC
6+6+246+9+24 6+12+249+9+24 9+12+24 or 12+12+24
6+15+24 6+18+24 9+15+249+18+24 12+15+24 or 12+18+24
15+15+24 15+18+24 or 18+18+24
15+24+24 or 18+24+24
Combinations of 4 or more zones
1-PAC-SG76RJ-E
See notes for application below
2
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
See notes for application below
PORT A =38 gas x 14 liquid
PORT B =38 gas x 14 liquid
PORT C =38 gas x 14 liquid
PORT A =38 gas x 14 liquid
PORT B = 38 gas x 14 liquid
PORT C = 38 gas x 14 liquid
PORT D =38 gas x 14 liquid
PORT E =12 gas x 14 liquid
Notes for application bull Check the lineset sizes for your indoor selected models bull Select the branch box or boxes needed for your application bull Compare indoor unit lineset sizes as compared to branch
box sizes bull Connect 15K + indoor units to the larger port on the
(PAC-AKA51 BC) bull Adapt lineset size with appropriate port adapter from
above list bull When using the PU-A24BA or PEAD-A24AA two port
adapter will be needed 1-MAC-A456JP-E (12 x 58) or 1-PAC-SG76RJ-E (38 x 58) and 1-PAC493PI (14 x 38)
-fv
~ DIAMONDBACKtrade
~) BV-Series Ball Valves Model numbers
BV14FFSI BV38FFSI
LISTED 891N REFRIGERANT
BV12FFSI VALVE bull Engineered for Mini-split andBV58FFSI
Multi-split HVAC Units bull Size available 14 38 12 58
bull Full Port Designbull Fully factory assembled bull Furnace brazed and pressure tested bull 700 PSIG Rated bull Each ball valve is equipped with Schraderreg Valve
for refrigerant service bull R-410A Compatible bull Design working pressure 700 PSIG bull Temperature range bull Flare Connections
-40 0 F to +3250 F (-400 C to + 1490
C) bull Forged brass body and seal cap bull Teflonreg seals and gaskets (no synthetic a-rings) bull Seal cap design permits valve operation without
removal of seal cap bull Suitable for use with R-11 R-22 R-123 R-125
R-134A R-236FA R-4202A R-402B R-404A R-407C R-410A R-500 R-502 and R-507
bull One year limited materials and workmanship
Part Number SAE Flare
A B C 0 E F
BV14FFSI 14 619 260 180 122 142 110
BV38FFSI 38 630 267 180 122 142 110
BV12FFSI 12 651 267 180 122 142 110
BV58FFSI 58 664 267 180 128 142 110
Ball valves come With an insulation piece warranty on Ball Valves
~ DIAMONDBACKtrade
~) Platform Stands
Lift the Mitsubishi Electric Comfort Solution
outdoor unit to new heights with our Diamondback Platform Stands
bull Easy to install
bull Available for all sizes of Mr Slim outdoor units
bull Color matched to the outdoor units
Model Number DSD-400N
L 15-34 x W 3-14 x H 3-14
r
)MITSUBISHI ELECTRIC 29
~ DIAMONDBACKtrade LINESETS
~~
Twin-Tube Lineset Insulation Design
bull Balanced outside diameter for uniform coiluncoil position stability
bull Minimum 12 insulation thickness on both tubes Diamondback Advantages include the following features
bull Quick efficient and economical field installation using factory applied Twin Tube insulation and flare connections with flare nuts mounted
bull Correct lengths for reducing waste and time
bull Quality consistency and economy
bull All Diamondback Lineset tubing is tested in accordance with ASTM E243
Filter Boxes
FB Series filter boxes are available in compatible sizes for all Mr Slim horizontal ducted indoor units
FBL 1 filter boxes include 1 thick pleated MERV 8 filter(s) installed Filters are tested in accordance with ANSIASHRAE Standard 522 and Rated Class 2 under UL Standard 900
The cabinet is constructed of non-insulated 20 gauge G-60 galvanized
FBL1-1 FB Series Filter Box for SEZ-KD09NA
FBL1-2 FB Series Filter Box for SEZ-KD12KD15-NA
FBL1-3 FB Series Filter Box for SEZ-KD18NA
steel with foam gasket and provides an air-tight connection to indoor unit and access door Gasket material complies with UL 723 requirements
A screw-through cabinet design for secure attachment to indoor unit and return connection in rear is easily field-converted to bottom return
30 MITSUBISHI ELECTRIC
bull
bull
bull
bull
bull
bull
LINE-HIDE~ Put a professional finish on air-conditioning
installations with an easy-to-install modular
system that beautifies exteriors and
protects Linesets drainlines and wiring
Can be use it indoors too Meets UL94v-O for interior applications
Has snap-on covers and a full selection of couplings elbows T-joints caps and more for any application complex or simple
Offers high-quality PVC with UV inhibitors for outdoor service in all weather conditions
Can be painted with most house paints to match exterior decors
Is not just for HVAC Hide any exterior cabling piping or wiring
Available in four sizes 2-14 3 4 and 6 tubes
Download a brochure at wwwline-hidecom to find out more information
For more information on our CITY MULTI VRF product line visit our website at wwwmitsubishiprocom
_lIJrUlllln ~ ~IIII1 fInll l
~
l bull bull
JMITSUBISHI ELECTRIC 31
MULTI-ROOM MXZ-8 INVERTER HEAT PUMP R
Model Name Outdoor Unit MXZ-2B20NA-1 5 MXZ-3B24NA 6 MXZ-3B30NA MXZ-4B36NA 7
Indoor Unit
Cooling 1 Non-ductedl Ducted
Rated Capacity Btuh 1800020000 2200023600 28400127400 3540034400
Capacity Range Btuh 7800-20000 12600-25500 12600-28400 12600-36400
Total Input W 2190 (630-219QL 2460 (1000-2950) 3330 l1 000-3330) 3 940 (1 000-4020)
Heating at 4JO F 2 Non-ductedl Ducted
Rated Capacity Btuh 2200022000 2500024600 2860027600 3600034400
Capacity Range Btuh 8500-25500 11400-30600 11 400-36000 11400-43000
Total Input W 2620 (520-2620) 1900 (740-2600) 2220 (740-2820) 3100 (740-3940)
Heating at 1JO F 3 Non-ductedl Ducted
Rated Capacity Btuh 1250012500 1400014000 1600015100 2220020300
Rated Total Input W 13501430 13801570 21202 140 24302340
Maximum Capacity Btu h 1450014500 1880017000 1880018000 2460025400
Maximum Total Inl2ut W 15001590 21202230 21202140 33403450
Power Supply Phase Cycle Voltage 1-phase 60Hz 2081 230V 8
Voltage Indoor shy Outdoor S1 - S2 AC 2081 230V
Indoor shy Outdoor S2 - S3 DC12-24V
Outdoor Unit 4
MCA A 15 19
MOCP A 20
Fan Motor FLA 096 093
Compressor
Model (Type)
DC INVERTER-driven Twin Rotary
RLA 101 11 144
LRA 15
Airflow (CoolingHeating) CFM 14851 640 20681605 13651605 20682068
Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling 1
dB(A) 49 54 49 54
Sound Pressure Level at Heating 2
dB(A) 51 49 57
External Finish Color Munsell No 30Y 781 1
Dimensions
W In 33-116 35-716
D In 13 12-58
H In 27-1516 35-7116
Weight Lbs 130 150 153
Indoor Unit No of Units 2 23 23 234
Remote Controller Type Associated with the Indoor Unit
Refrigerant
Type R410A
Charge Lbs Oz 515 7 11 813
Oil Type (fl oz)
NE022 (237) NE022 (294)
Refrigerant Pipe Gas Side 00 In AB 38 A 12 BC 38 A 12 BCD 38
Liquid Side 00 In 14
Refrigerant Pipe Length Height Difference (Max) Ft 4933 9
Length (Max) Ft 164 (A+B) 230 (A+B+C) 230 (A+B+C+D)
Connection Method IndoorOutdoor FlaredlFlared
Compatible with the MSZ-A MSZ-GA MSZ-FD MSZ-FE MSZ-GE MFZ-KA and SEZ-KD series indoor units (PLA-18 amp PCA-24 on the MXZ-MXZ-3B PLA-24 amp PCA-24 on the MXZ-4B)
NOTES Test conditions are based on AHRI 210240 One indoor unit is turned off during low-speed testing under the new test conditions Systems actually exhibit higher energy efficiencies during normal operation
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F (35deg C) WB 75deg F (24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F (6deg C) 3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 600 F (160 C) Outdoor DB 17deg F (_80 C) WB 150 F (_90 C) 4 Refer to pages 12 and 13 for Indoor Unit specifications 5 Data from combination of two Indoor Units 9000 Btuh (non-ducted) or one 9000 Btuh and one 12000 Btuh (ducted) 6 Data from combination of two Indoor Units 6000 Btuh and one 9000 Btuh (non-ducted) or three 9000 Btuh (ducted) 7 Data from combination of four Indoor Units 9000 Btuh (non-ducted and ducted) 8 Indoor units receive power from outdoor units through field-supplied interconnected wiring 9 49 Applies to installations where the outdoor unit is installed below the indoor unit
Power factor equals 97 percent
Specifications are subject to change without notice
MULTI-ZONE ENERGY STAR AND TAX CREDIT SYSTEMS
Model Indoor Unit Combinations SEER HSPF
MXZ-2B20NA-1 2 x MSZ- GE09NA 18 8 9
MXZ- 3B24NA 2 x MSZ- GE06NA 1 x MSZshy GE09NA
17 5 9 3
MXZ- 3B24NA 2 x MSZ-GE06NA 1 x MSZ- GE12NA
17 5 93
For more details on all ENERGY STAR and tax credit systems go to wwwmitsubishicomfortcomtaxcredit
See page 25 for additional info on efficiency
LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 21
MXZ-8B48NA THE ULTIMATE ZONING SOLUTION
The Mitsubishi Electric MXZ-S84SNA eight-zone unit As a member of the expanding MXZ-B Series of multi-zone systems the MXZ-8B outdoor unit incorporates branch boxes to connect up to eight indoor units MXZ- 8 B48 NA (2 1 - 8 1 )
Outd oor Uni t The INVERTER-driven compressor at the heart of the MXZ-8B -~-- shy
outdoor unit provides variable capacity control allowing the system to adjust to the specific demands of the interior space ~ as needed not the hard start and stop of a traditional system I[iDA Jinstalled in most US homes
The MXZ -8B48NA has only one port on the outdoor unit for two insulated refrigerant lines which run into the home or business to connect to a branch box or boxes From the branch box(es) gas and liquid refrigerant piping run to each of the indoor units The LEV in the branch box(es) controls the refrigerant flow as the load of each zone changes
Through the branch box(es) (the PAC-AKA31 BC three-port andor the PAC-AKA51 BC five-port) the system can connect from two indoor units up to eight indoor units depending on application requirements
The flexibility of the system doesnt stop there The MXZ-8B48NA has rated capacities of 48000 Btuh for cooling and 54000 Btuh for heating System operation however can range from a minimum 12000 Btuh to a maximum 54000 Btuh in cooling and a maximum of 60000 Btuh in heating This type of performance supports a large variety of applications
The MXZ-8B48NA allows for further flexibility because it supports a connected indoor unit capacity from 22 to 130 or 12000 Btuh to a maximum 70200 Btuh depending on diversity
Connectable Indoor Units General Features bull Four-ton outdoor unit can support up to
eight indoor units using branch boxes bull Wide variety of indoor unit styles
-=--_-=-----= - - J _ 1
including wall-mounted floor-standing MSZ-FE09 12 18NA MSZ-GE06 09 12 15 18 24NA ceiling-cassette ducted
bull Individual control up to eight (8) zones using wired or wireless controls
bull Advanced microprocessor control bull Auto restart following a power outage bull Self-check function offering SEZ-KD09 1215 18NA PEAD-A24AA
integrated diagnostics ~--- Jbull Limited warranty five years on parts and
defects and seven years on compressors
SLZ-KA09 1215NA MFZ-KA09 12 18NA
22 MITSUBISHI ELECTRIC LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
I
RMULTI-ROOM MXZ-8 INVERTER HEAT PUMP
Model Name Outdoor Unit MXZ-BB4BNA Cooling 1 Rated Capacity
Non-ducted Rated Total Input Ducted
Maximum Capacity
Rated CapacityHeating at
Rated Total InputIndoor Unit 4JO F 2 Non-
ductedDucted Maximum Capacity
Rated Capacity Heating at
Rated Total InputlJO F 3 Non-ductedDucted Maximum Capacity
Power Supply Phase Cycle Voltage
Indoor - Outdoor Sl - S2 Voltage
Indoor - Outdoor S2 - S3
MCA
Recommended FuseBreaker Size
Fan Motor
Compressor
Airflow (CoolingHeating)
Refrigerant Control
Outdoor Unit Sound Pressure Level at Cooling 1
Sound Pressure Level at Heating 2
External Finish Color
Dimensions
Weight
Total Capacity 22-130
Indoor Unit ModelQuantity
Remote Controller Type
Type
Refrigerant Charge
Oil
Gas Side OD Refrigerant Pipe
Liquid Side OD
Height Difference (Max)
Maximum Distance between (Outdoor unit and farthest indoor unit)
Refrigerant Pipe Length Maximum Pipe Length -Branch box to Indoor Unit
Total Maximum line length between Branch Box and All Connected Indoor Units
Total Length (Max)
Connection Method IndoorOutdoor
Includes both branch boxes if there are two
Branch Boxes (At least one branch box required)
Btuh
W
Btuh
Btuh
W
Btuh
Btuh
W
Btuh
A
A
Type x Quantity
Motor Output (kW)
Model (Type)
Motor Output (kW)
CFM
dB(A)
dB(A)
W In
D In
H In
Lbs
Btuh
Lbs Oz
Type (fl oz)
In
In
Ft
Ft
Ft
Ft
Ft
4800048000
57806470
54000
5400054000
48205270
60000
3300034700
29503390
3660036550
1 Phase 60Hz 208 230V
AC 208-230V
DC12-24V
32
40
Propeller x 2
0086 + 0086
DC INVERTER-driven Scroll
29
3530
Linear Expansion Valve
54
55
Munsell No 3Y 78 11
37-716
13+1-3 16
53-3 16
278
12000 - 70200
600 - 24000 2-8
Associated with Indoor Unit Model
R410A
18 112
FV50S (73)
58
38
6698 4
230
49
197
377
FlaredFlared
Compatible with the MSZ-A MSZ-FO MSZ-FE MSZ-GE MFZ-KA SEZ-KD PLA and PEAD series indoor units
NOTES Test conditions are based on AHRI 210240 One indoor unit is turned off during low-speed testing under the new test conditions Systems actually exhibit higher energy efficiencies during normal operation
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F (35deg C) WB 75deg F (24deg C)
2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 4]0 F (8deg C) WB 43deg F (6deg C)
3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 17deg F (-8deg C) WB 15deg F(-9deg C)
4 66 applies to installations when the outdoor unit is installed below the indoor unit
Power factor equals 97 percent
Specifications are subject to change without notice
Note Maximum installed capacity is the maximum total of all connected indoor units NOT the maximum capacity produced
Only a single Lineset is needed from the outdoor unit to branch box
See page 25 for MXZ-B information on efficiency
Required Branch Boxes for MXZ-SB4BNA (Maximum of 2 branch boxes can be connected to one outdoor unit requires joint MSDD-50AR-E or MSDD-50BR-E)
s c d N o J ro Vl
0 ro n 3i n OJ d o J U)
PAC-AKA51 BC Branch Box
PAC-AKA31 BC Branch Box LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 23
MSZ WALL-MOUNTED INDOOR UNITS (FOR MXZ-8 OUTDOOR UNITS)
R
(MSZ-GE12NA MODEL SHOWN)
-000 IIIIIII 9000 9000 12000 12000 14000 17200
Heating at 4r Rated Capacity Btuh 7200 10900 10900 14400 13600 18000 21600
F2 Power Supply I Phase Cycle Voltage J -phase 60Hz 208 230V 3
Iindoor Outdoor S1 S2 AC 208 230V
Iindoor Outdoor S2 S3 DC12-24V Voltage
Iindoor Remote vomr Iller Wireless Type (Optional Wired vomroller DC 12V)
IMCA A 10 IFan Motor FLA 076
DRY 162-226shy145-170shy
162-226shy205-272shy 230-275shy
Airflow at Cooling (CFM)
145-170-237-321-399 339-381
237 -321shy381-410
335-420shy 339-420shy(Quiet-Lo-Med-Hishy 399 533 533 Super Hi or Lo-Med-
WET 144-202shy109-134shy
144-202shy170-237shy 194-240shy
Fan Hi-Powerful)1 (CFM)
109-134-201-286-364 307-343
201-286shy350-367
300-385shy 304-385shy364 498 498
Airflow at Heating 145-170shy 145-170shy 145-170shy 205-247shy 230-275shy
(Quiet-Lo-Med-Hi- WET 233-321shy 237-321shy
166-240shy237-321shy
166-240shy304-367shy 339-431shy
Super Hi or Lo-Medshy (CFM) 406 406
367 -381 406
399-420 463 512
Hi-Powerful) 2 Sound Pressure Level at Cooling
19-22-30shy 26-32-38shy 28-33-38shy(Quiet-Lo-Med-Hi-Super Hi or Loshy dB(A) 19-22-30-37 -43 22-31-39-42
37-45 22-33-43-45
44-49 44-49Med-Hi-Powerful) 1
Sound Pressure Level at Heating 19-22-30shy 26-30-35shy 28-33-38shy
(Quiet-Lo-Med-Hi-Super Hi or Loshy dB(A) 19-22-30-37 -43 22-31-40-42 37-43
22-23-43-44 40-46 43-48
Med-Hi-Powerful) 2
I External Finish Color Munsell No 10Y 92 02
IWln 31 middot716
Dimension Unit 10 In 9 18 10-18 9middot18 10-18 9-18
IH In 11-58
I Weight Unit ILbs 22 27 22 27 22 I Field Drainpipe ~D lin 58 Remote Con-
Type Wireless Remote (Optional Wired Controller) troller
ITvpe B41QA Refrigerant ~s$ideOD lin 38 Pipe I Liquid Side 00 In 14
Connection IndoorOutdoor FlaredFlared
Method
1~
II 18000 22500
21600 27600
388-469shy 38$-469shy628-738 628-738
347-420shy 347-420shy562-661 562-661
388-469shy 388-469shy628-738 628-738
34-41-49-53 34-41-49-53
32-41-49-52 32-41-49-52
43-516
9-38
12-1316 37
58 38
MXZ-2B20NA is also compatible with the MSZ-A and MSZ-FD series indoor units NOTES Test conditions are based on AHRI 210240
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F(6deg C) 3 Indoor units receive power from outdoor units through field-supplied wiring
Specifications are subject to change without notice LIMITED WARRANTY Seven-year warranty on compressor Five-year warranty on parts For data on specific indoor unit combinations see page 21
SEZ DUCTED INDOOR UNIT (FOR MXZ-8 OUTDOOR UNITS)
I
Notes 1 Cooling-Indoor DS 80deg F(267deg C) WS 67deg F(194deg C) Outdoor DS 95deg F (35deg C) WS 75deg F(239deg C)
2 Heating-Indoor DS 70deg F(211 deg C) WS 60deg F(156deg C) Outdoor DS 47deg F (83deg C) WS 43deg F(61 deg C)
3 External static pressure is factory set to 006 WGAdjustable via the
1---------t---+-----L-------------1~---__I PAR-21MAA
1--_____----__________+-____---L____----~_____________1 4 Indoor units receive power
jE~~~~-------------r----1-----~-~~~~~~~~-----___1 from outdoor units through fieldsupplied interconnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven-year warranty on compressor Five-year
1---------------------+---+------------------------1 warranty on parts
~--__I_~----------+-------~l----------I For data on specific indoor unit combinations see page 21 - 23
I--~------+~-----------~----------r_------------I
- Reference page 17 for SEZ static performance curves
24 MITSUBISHI ELECTRIC
25-30-35-40 26-31-36-41 35-38-42-46
25-30-35-40 28-31-36-41 35-38-42-47
MFZ FLOORLOW WALL INDOOR UNIT (FOR middotMXZ-8 OUTDOOR UNITS)
------shy
-==
Airflow at Heating (CFM) 177-198-219-332 184-201-219-335 261-275-297-434
Voltage
Fan
Airflow at Cooling (Lo-Med-Hi-Super Hi)1
169-205-251-314 251-279-325-394
163-197-241-303 170-207-252-309 241-269-313-379
(Lo-Med-Hi-Super Hi) 2
SLZ CEILING-RECESSED INDOOR UNIT (FOR MXZ-8 OUTDOOR UNITS) EFFICIENCY RATINGS
Voltage
Fan
Galvanized-steel SheetsMunsell 64Y 89 04
Refrigerant Pipe
Model Indoor Unit Type SEER HSPF
MXZ-2B20NA-1
Non-dueted 18 89
Dueted and Non-dueted 1675 87
Dueted 155 85
MXZ-2B20NA-1 ENERGY STAR amp
TAX CREDIT 2 x MSZ-GE09NA 18 89
MXZ-3B24NA
lJon-dueted 175 93
Dueted and Non-dueted 1625 89
Dueted 150 85
MXZ-3B24NA ENERGY STAR amp
TAX CREDIT
2 x MSZ-GE06NA 1 x MSZ-GE09NA
175 93
MXZ-3B24NA ENERGY STAR amp
TAX CREDIT
2 x MSZ-GE06NA 1 x MSZ-GE12NA
175 93
MXZ-3B30NA
Non-dueted 175 105
Dueted and Non-dueted 16 100
Dueted 145 95
MXZ-4B36NA
Non-dueted 18 93
Dueted and Non-dueted 16 5 92
Dueted 150 9 0
MXZ-BB4BNA
Non-dueted 15 87
Dueted and Non-dueted 14B B8
Dueted 147 89
Connection IndoorOutdoor FlaredFlared
Method
Notes 1 Cooling-Indoor DB 80deg F(267deg C) WB 67deg F(194deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(239deg C) 2 Heating-Indoor DB 70deg F(21 1 deg C) WB 60deg F(156deg C) Outdoor DB 47deg F(83deg C) WB 43deg F(61 deg C) 3 Indoor units receive power from outdoor units through field supplied interconnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 25
Notes 1 Cooling-Indoor DB 80deg F(267deg C) WB 67deg F (194deg C) Outdoor DB 95deg F (35deg C)WB 75deg F (239deg C)
2 Heating-Indoor DB 70deg F(211deg C) WB 60deg F (156deg C) Outdoor DB 47 F (83deg C) WB 43deg F (61 deg C)
3 Indoor units receive power from outdoor units through field supplied interco(lnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven -year warranty on compressor Five-year warranty on parts
Presently there is no 1 1 system with the MFZ indoor unit
s c
N o J ro Vl
C ro n ~ n OJ t o J V)
M-SERIES RATING CONDITIONS
INDOOR INTAKE AIR TEMPERATURE
OUTDOOR INTAKE AIR TEMPERATURE
COOLING
MAXIMUM
95degF DB 71 degF WB (MU SUZ MXZ-2B20-13B243B304B36) 90degF DB 73degF WB (MUZY-GE MUZ-FE MUzy-D)
115degF DB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B24 3B304B368B48)
MINIMUM 67degF DB 57degF WB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B201 3B243B304B36)
14degF DB (MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B24 3B304B36) 23degF DB (MXZ-8B48) 6rF DB (MU)
MAXIMUM 80degF DB 6rF WB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B243B304B36)
75degF DB 65degF WB (MUZY-GE MUZY-GA24 MUZ-FE SUZ MXZ-2B20-1 3B243B304B36) 70degF DB (MXZ-8B48)
HEATING
MINIMUM 70degF DB 60degFWB (MUZ-GE MUZ-GA24 MUZ-D MUZ-FE SUZ MXZ-2B20-1 3B243B304B36)
-13degF DB -15degFWB (MUZ-FE) -4degF DB -5degF WB (SUZ MUZ-GE) 5degF DB 4degF WB (MUZ-GA24 MXZ-8B48NA) 6degF DB 5degF WB (MXZ-2B20-1 3B24 3B304B36) 14degF DB 13degFWB (MUZ-D)
MU units operate at intake air temperature down to 10deg Fwith the addition of an ICM-326HM-1 low temperature control
REFRIGERANT TUBING SETS
OPTIONAL ACCESSORIES
REFRIGERANT LINE LENGTH FLARE FLARE _INDOOR UNIT OUTDOOR UNIT
MS-A09WA MU-A09WA 35 MS-A12WA
65 MU-A12WA 35
MSY-GE09NA 65
MUY-GE09NA 40
MSY-GE12NA
65
MUY-GE12NA 65 40
MSY-GE15NA MUY-GE15NA 40
MSY-GE18NA
65
MUY-GE18NA 100 50
MSZ-GE09NA MUZ-GE09NA 65 40
MSZ-GE12NA MUZ-GE12NA 40
MSZ-GE15NA
65
MUZ-GE15NA 40
MSZ-GE18NA
65
MUZ-GE18NA 100 50
MSY-GE24NA MUY-GE24NA 100 50
MSZ-GE24NA MUZ-GE24NA 100 50
MSY-D30NA MUY-D30NA 100 50
MSZ-D30NA MUZ-D30NA 50
MSY-D36NA
100
MUY-D36NA 50
MSZ-D36NA
100
MUZ-D36NA 100 50
MSZ-FE09NA MUZ-FE09NA 40
MSZ-FE12NA
65
MUZ-FE12NA 40
MSZ-GE06091215NA MSZ-FE0912NA
65
MXZ-2B20NA-1 164 4933MFZ-KA0912NA SEZ-KD09 1215NA
MSZ-GE0609 121518NA MSZ-FE091218N MFZ-KA09 1218NA MXZ-3B24NA 164 4933 SEZ -KD09 12 15 18NA SLZ-KA09 12 15NA
MSZ-GE0609 121518NA MSZ-GA24NA MSZ-FE091218NA
MXZ-3B30NA 4933230MFZ-KA091218NA SEZ -KD09 121518NA SLZ-KA09 12 15NA
MSZ-GE0609121518NA MSZ-GE24NA MSZ-FE09 12 18NA
MXZ-4B36NA 230 4933MFZ-KA091218NA SEZ -KD09121518NA SLZ-KA09 12 15NA
MSZ-GE0609 12 15 18NA MSZ-GE24NA MSZ-FE09 12 18NA
MXZ-8B48NA 6698377MFZ-KA091218NA SEZ-KD09121518NA SLZ-KA09 12 15NA
PART NUMBER I USE WITH I DESCRIPTION
Port Adapters and Connection Pipes MAC-A454JP-E MXZ-Series Adapter 38 X12
MAC-A455JP-E MXZ-Series Adapter 12 X38
MAC-A456JP-E MXZ-Series Adapter 12 X58
MSDD-50AR-E MXZ-Series Branch Box Tee Distribution Pipe - Flare Connection between two branch boxes
MSDD-50BR-E MXZ-Series Branch Box Tee Distribution Pipe - Braze Connection between two branch boxes
PAC-493PI MXZ-Series Adapter 14 X38
PAC-SG76RJ-E MXZ-Series Adapter 38 X58
OPTIONAL ACCESSORIES CONTINUED ON NEXT PAGE
49 amp 66 applies to installations in which the outdoor unit is installed below indoor unit26 MITSUBISHI ELECTRIC
OPTIONAL ACCESSORIES (CONTINUED)
PART NUMBER USE WITH DESCRIPTION Control Options and Accessories
M21 JKO 307 M-Series Indoor Units Remote temperature sensor for M-Series indoor units
MAC-397IF-E
MAC-399IF-E
PAC-YU25HT
PAR-21 MM-G
M-Series INVERTER Units
M-Series INVERTER Units
SEZ-KD Indoor Units
Use with P-Series SEZ and for wired M-Series Controller
MA and contact terminal interface - Required to use PAR-21 MM wired wall mount controller with M-Series Systems
CMCN M-NET control adapter I Interface for Mr Slim M-Series MSYZ SEZ I MFZ
External Fan I Heater control relay adapter
Deluxe MA remote controller (Requires MAC-397IF-E for use with M-Series - MSYZ MFZ)
SEZ Wireless remote controller for SEZ units (Requires signal receiver PAR-SA9FA-E)PAR-FL32MA
PAR-SA9CA-E SEZ Wireless signal receiver for SEZ
3-pole disconnect switch 30A 600V turns off power between indoor and outdoor units shyM-SeriesTAZ-MS303
mounts in 2 X 4 utility box and requires standard single gang switch platecover - Low Ambient
ICM-326HM-2 M-Series Non-INVERTER units Low ambient head pressure controller MUZ-GE091215 IVIUZ-FE0912 SUZ-KD091215
Drain pan heaterMAC-640BH-U outdoor unit
MAC-641 BH-U MUZ-GE18 SUZ-KD18 outdoor unit Drain pan heater Filters
MAC-1415FT-E Anti-allergy enzyme filter
MAC-2300FT
MSZlMSY-D3036
Anti -allergy enzyme filter
MAC-308FT
MSYMSZ-GA24
MSZ-FD912 I FE0912 Platinum deodorizing filter
MAC-408FT-E Anti-allergy enzyme filter
MAC-415FT-E
M-Series Indoor Unit - GE09GE12GE15GE18
MFZ-KA Air Cleaning FilterAnti-Aliergy Enzyme Filter
MAC-418FT Anti-allergy enzyme filter
Filter Boxes
FBL1-1
MSZ- FD912 I FE091 2
FB Series Filter Box for SEZ-KD09NA Optional filter box with MERV 8 filters
FB Series Filter Box for SEZ-KD1215NAFBL1-2 Optional filter box with MERV 8 filters
and PEA-A 12M
FBL1-3 FB Series Filter Box for SEZ-KD18NA Optional filter box with MERV 8 filters
Pumps
SI1730-230 MSYZ - 30000 Btuh or greater Sauermann mini condensation pump 230V
S13100-115 MS-Series - non-INVERTER Sauermann mini condensation pump 115V
S13100-230 Sauermann mini condensation pump 230VMSYZ - Less than 30000 Btuh
Miscellaneous BRP-1 Bottom Return Plate for SEZ-KD09NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-2 Bottom Return Plate for SEZ-KD12KD15-NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-3 Bottom Return Plate for SEZ-KD18NA Converts low profile ducted indoor unit from rear return to bottom return
BV12FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderreglnsulated - 12
BV14FSI Use with any Mr Sl im multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 14
BV38FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 38
BV58FSI Use with any IVIr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 58
Condensing unit wall mounting brackets (set of 2) - 440 lb capacity painted steel NOTE CWMB1 IVIU and PU outdoor units Installer is responsible to select and provide suitable hardware and materials to insure proper
mount of bracket to wall
DSD-400N M-Series DiamondBacktrade Platform Stands MUZ-GE18 I MUZ(y)-03036 I
MAC-811DS Drain socket assemblySUZ-KA18
MAC-851DS MUZ-FD0912 Drain socket
MAC-855SG M-Series Air outlet guide
MAC-856SG M-Series Air outlet guide - MXZ-3B24 I 3B30 I 4B36 NA
MAC-860DS MUZ-GE091215 I MUZ-FE0912 Drain socket
MAC-889SG M-Series Air outlet guide- MXZ-2B20NA
MAC-S99SG M-Series Air outlet guide
PAC-SG59SG-E IVIXZ-SB4SNA Air outlet guide (1 piece) I MXZ-SB48NA (Requires 2 pieces)
PAC-SG61 DS-E MXZ-8B4SNA Drain socket - connector
PAC-SG64DP-E MXZ-SB48NA Drain pan
RCMKP1CB lVI-Series Wireless Lockdown bracket for remote controller
lILTRILlTE1 All M-Series Condensing unit mounting pad 16 x 36 x 3
MITSUBISHI ELECTRIC 27
MXZ-8 Series Port Adapter chart Port Adapter Unit Port
Combinations Required Size
MXZ-2B20NA-1
2-zone combinations wi NA
A 38 x both units s12K 14
1-MAC-A454JP-E B 38 x
6+15 14
9+15 1-MAC-A454JP-E
MXZ-3B24NA
All rated 2-zone combina-NA
A 12 x tions 14
All rated 3-zone combina-NA
B 38 x tions 14
C 38 x 14
MXZ-3B30NA
2-zone combinations wi at NA
A 12 x least one unit s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
9 + 24 14
3-zone combinations wi 1-MAC-A455JP-E
all units s12K
All other rated 3-zone NA
comb
MXZ-4B36NA
2-zone combinations wi at NA
A 12 x least one un it s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
6 + 24 14
1-MAC-A456JP-E D 38 x
9 + 24 14
3-zone combinations wi at NA
least two units s12K
3-zone combinations wi 1-MAC-A454JP-E
two units15K
6+6+24 or 6+9+24 1-MAC-A456JP-E
9+9+24 1-MAC-A456JP-E
4-zone combinations wi at 1-MAC-A455JP-E
least three units s12K
6+6+15+15 1-MAC-A454JP-E
6+6+15+15 1-MAC-A454JP-E
Note When using the Pu-A24BA PCA-A24KA or PEAD-A24AA two port adapter will be needed 1-MAC-A456JP-E (12 x 58) A port or 1-PACshySG76RJ-E (38 x 58) B C and D ports and 1-PAC493PI (14 x 38)
28 JMITSUBISHI ELECTRIC
6+6+246+9+24 6+12+249+9+24 9+12+24 or 12+12+24
6+15+24 6+18+24 9+15+249+18+24 12+15+24 or 12+18+24
15+15+24 15+18+24 or 18+18+24
15+24+24 or 18+24+24
Combinations of 4 or more zones
1-PAC-SG76RJ-E
See notes for application below
2
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
See notes for application below
PORT A =38 gas x 14 liquid
PORT B =38 gas x 14 liquid
PORT C =38 gas x 14 liquid
PORT A =38 gas x 14 liquid
PORT B = 38 gas x 14 liquid
PORT C = 38 gas x 14 liquid
PORT D =38 gas x 14 liquid
PORT E =12 gas x 14 liquid
Notes for application bull Check the lineset sizes for your indoor selected models bull Select the branch box or boxes needed for your application bull Compare indoor unit lineset sizes as compared to branch
box sizes bull Connect 15K + indoor units to the larger port on the
(PAC-AKA51 BC) bull Adapt lineset size with appropriate port adapter from
above list bull When using the PU-A24BA or PEAD-A24AA two port
adapter will be needed 1-MAC-A456JP-E (12 x 58) or 1-PAC-SG76RJ-E (38 x 58) and 1-PAC493PI (14 x 38)
-fv
~ DIAMONDBACKtrade
~) BV-Series Ball Valves Model numbers
BV14FFSI BV38FFSI
LISTED 891N REFRIGERANT
BV12FFSI VALVE bull Engineered for Mini-split andBV58FFSI
Multi-split HVAC Units bull Size available 14 38 12 58
bull Full Port Designbull Fully factory assembled bull Furnace brazed and pressure tested bull 700 PSIG Rated bull Each ball valve is equipped with Schraderreg Valve
for refrigerant service bull R-410A Compatible bull Design working pressure 700 PSIG bull Temperature range bull Flare Connections
-40 0 F to +3250 F (-400 C to + 1490
C) bull Forged brass body and seal cap bull Teflonreg seals and gaskets (no synthetic a-rings) bull Seal cap design permits valve operation without
removal of seal cap bull Suitable for use with R-11 R-22 R-123 R-125
R-134A R-236FA R-4202A R-402B R-404A R-407C R-410A R-500 R-502 and R-507
bull One year limited materials and workmanship
Part Number SAE Flare
A B C 0 E F
BV14FFSI 14 619 260 180 122 142 110
BV38FFSI 38 630 267 180 122 142 110
BV12FFSI 12 651 267 180 122 142 110
BV58FFSI 58 664 267 180 128 142 110
Ball valves come With an insulation piece warranty on Ball Valves
~ DIAMONDBACKtrade
~) Platform Stands
Lift the Mitsubishi Electric Comfort Solution
outdoor unit to new heights with our Diamondback Platform Stands
bull Easy to install
bull Available for all sizes of Mr Slim outdoor units
bull Color matched to the outdoor units
Model Number DSD-400N
L 15-34 x W 3-14 x H 3-14
r
)MITSUBISHI ELECTRIC 29
~ DIAMONDBACKtrade LINESETS
~~
Twin-Tube Lineset Insulation Design
bull Balanced outside diameter for uniform coiluncoil position stability
bull Minimum 12 insulation thickness on both tubes Diamondback Advantages include the following features
bull Quick efficient and economical field installation using factory applied Twin Tube insulation and flare connections with flare nuts mounted
bull Correct lengths for reducing waste and time
bull Quality consistency and economy
bull All Diamondback Lineset tubing is tested in accordance with ASTM E243
Filter Boxes
FB Series filter boxes are available in compatible sizes for all Mr Slim horizontal ducted indoor units
FBL 1 filter boxes include 1 thick pleated MERV 8 filter(s) installed Filters are tested in accordance with ANSIASHRAE Standard 522 and Rated Class 2 under UL Standard 900
The cabinet is constructed of non-insulated 20 gauge G-60 galvanized
FBL1-1 FB Series Filter Box for SEZ-KD09NA
FBL1-2 FB Series Filter Box for SEZ-KD12KD15-NA
FBL1-3 FB Series Filter Box for SEZ-KD18NA
steel with foam gasket and provides an air-tight connection to indoor unit and access door Gasket material complies with UL 723 requirements
A screw-through cabinet design for secure attachment to indoor unit and return connection in rear is easily field-converted to bottom return
30 MITSUBISHI ELECTRIC
bull
bull
bull
bull
bull
bull
LINE-HIDE~ Put a professional finish on air-conditioning
installations with an easy-to-install modular
system that beautifies exteriors and
protects Linesets drainlines and wiring
Can be use it indoors too Meets UL94v-O for interior applications
Has snap-on covers and a full selection of couplings elbows T-joints caps and more for any application complex or simple
Offers high-quality PVC with UV inhibitors for outdoor service in all weather conditions
Can be painted with most house paints to match exterior decors
Is not just for HVAC Hide any exterior cabling piping or wiring
Available in four sizes 2-14 3 4 and 6 tubes
Download a brochure at wwwline-hidecom to find out more information
For more information on our CITY MULTI VRF product line visit our website at wwwmitsubishiprocom
_lIJrUlllln ~ ~IIII1 fInll l
~
l bull bull
JMITSUBISHI ELECTRIC 31
MXZ-8B48NA THE ULTIMATE ZONING SOLUTION
The Mitsubishi Electric MXZ-S84SNA eight-zone unit As a member of the expanding MXZ-B Series of multi-zone systems the MXZ-8B outdoor unit incorporates branch boxes to connect up to eight indoor units MXZ- 8 B48 NA (2 1 - 8 1 )
Outd oor Uni t The INVERTER-driven compressor at the heart of the MXZ-8B -~-- shy
outdoor unit provides variable capacity control allowing the system to adjust to the specific demands of the interior space ~ as needed not the hard start and stop of a traditional system I[iDA Jinstalled in most US homes
The MXZ -8B48NA has only one port on the outdoor unit for two insulated refrigerant lines which run into the home or business to connect to a branch box or boxes From the branch box(es) gas and liquid refrigerant piping run to each of the indoor units The LEV in the branch box(es) controls the refrigerant flow as the load of each zone changes
Through the branch box(es) (the PAC-AKA31 BC three-port andor the PAC-AKA51 BC five-port) the system can connect from two indoor units up to eight indoor units depending on application requirements
The flexibility of the system doesnt stop there The MXZ-8B48NA has rated capacities of 48000 Btuh for cooling and 54000 Btuh for heating System operation however can range from a minimum 12000 Btuh to a maximum 54000 Btuh in cooling and a maximum of 60000 Btuh in heating This type of performance supports a large variety of applications
The MXZ-8B48NA allows for further flexibility because it supports a connected indoor unit capacity from 22 to 130 or 12000 Btuh to a maximum 70200 Btuh depending on diversity
Connectable Indoor Units General Features bull Four-ton outdoor unit can support up to
eight indoor units using branch boxes bull Wide variety of indoor unit styles
-=--_-=-----= - - J _ 1
including wall-mounted floor-standing MSZ-FE09 12 18NA MSZ-GE06 09 12 15 18 24NA ceiling-cassette ducted
bull Individual control up to eight (8) zones using wired or wireless controls
bull Advanced microprocessor control bull Auto restart following a power outage bull Self-check function offering SEZ-KD09 1215 18NA PEAD-A24AA
integrated diagnostics ~--- Jbull Limited warranty five years on parts and
defects and seven years on compressors
SLZ-KA09 1215NA MFZ-KA09 12 18NA
22 MITSUBISHI ELECTRIC LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
I
RMULTI-ROOM MXZ-8 INVERTER HEAT PUMP
Model Name Outdoor Unit MXZ-BB4BNA Cooling 1 Rated Capacity
Non-ducted Rated Total Input Ducted
Maximum Capacity
Rated CapacityHeating at
Rated Total InputIndoor Unit 4JO F 2 Non-
ductedDucted Maximum Capacity
Rated Capacity Heating at
Rated Total InputlJO F 3 Non-ductedDucted Maximum Capacity
Power Supply Phase Cycle Voltage
Indoor - Outdoor Sl - S2 Voltage
Indoor - Outdoor S2 - S3
MCA
Recommended FuseBreaker Size
Fan Motor
Compressor
Airflow (CoolingHeating)
Refrigerant Control
Outdoor Unit Sound Pressure Level at Cooling 1
Sound Pressure Level at Heating 2
External Finish Color
Dimensions
Weight
Total Capacity 22-130
Indoor Unit ModelQuantity
Remote Controller Type
Type
Refrigerant Charge
Oil
Gas Side OD Refrigerant Pipe
Liquid Side OD
Height Difference (Max)
Maximum Distance between (Outdoor unit and farthest indoor unit)
Refrigerant Pipe Length Maximum Pipe Length -Branch box to Indoor Unit
Total Maximum line length between Branch Box and All Connected Indoor Units
Total Length (Max)
Connection Method IndoorOutdoor
Includes both branch boxes if there are two
Branch Boxes (At least one branch box required)
Btuh
W
Btuh
Btuh
W
Btuh
Btuh
W
Btuh
A
A
Type x Quantity
Motor Output (kW)
Model (Type)
Motor Output (kW)
CFM
dB(A)
dB(A)
W In
D In
H In
Lbs
Btuh
Lbs Oz
Type (fl oz)
In
In
Ft
Ft
Ft
Ft
Ft
4800048000
57806470
54000
5400054000
48205270
60000
3300034700
29503390
3660036550
1 Phase 60Hz 208 230V
AC 208-230V
DC12-24V
32
40
Propeller x 2
0086 + 0086
DC INVERTER-driven Scroll
29
3530
Linear Expansion Valve
54
55
Munsell No 3Y 78 11
37-716
13+1-3 16
53-3 16
278
12000 - 70200
600 - 24000 2-8
Associated with Indoor Unit Model
R410A
18 112
FV50S (73)
58
38
6698 4
230
49
197
377
FlaredFlared
Compatible with the MSZ-A MSZ-FO MSZ-FE MSZ-GE MFZ-KA SEZ-KD PLA and PEAD series indoor units
NOTES Test conditions are based on AHRI 210240 One indoor unit is turned off during low-speed testing under the new test conditions Systems actually exhibit higher energy efficiencies during normal operation
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F (35deg C) WB 75deg F (24deg C)
2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 4]0 F (8deg C) WB 43deg F (6deg C)
3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 17deg F (-8deg C) WB 15deg F(-9deg C)
4 66 applies to installations when the outdoor unit is installed below the indoor unit
Power factor equals 97 percent
Specifications are subject to change without notice
Note Maximum installed capacity is the maximum total of all connected indoor units NOT the maximum capacity produced
Only a single Lineset is needed from the outdoor unit to branch box
See page 25 for MXZ-B information on efficiency
Required Branch Boxes for MXZ-SB4BNA (Maximum of 2 branch boxes can be connected to one outdoor unit requires joint MSDD-50AR-E or MSDD-50BR-E)
s c d N o J ro Vl
0 ro n 3i n OJ d o J U)
PAC-AKA51 BC Branch Box
PAC-AKA31 BC Branch Box LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 23
MSZ WALL-MOUNTED INDOOR UNITS (FOR MXZ-8 OUTDOOR UNITS)
R
(MSZ-GE12NA MODEL SHOWN)
-000 IIIIIII 9000 9000 12000 12000 14000 17200
Heating at 4r Rated Capacity Btuh 7200 10900 10900 14400 13600 18000 21600
F2 Power Supply I Phase Cycle Voltage J -phase 60Hz 208 230V 3
Iindoor Outdoor S1 S2 AC 208 230V
Iindoor Outdoor S2 S3 DC12-24V Voltage
Iindoor Remote vomr Iller Wireless Type (Optional Wired vomroller DC 12V)
IMCA A 10 IFan Motor FLA 076
DRY 162-226shy145-170shy
162-226shy205-272shy 230-275shy
Airflow at Cooling (CFM)
145-170-237-321-399 339-381
237 -321shy381-410
335-420shy 339-420shy(Quiet-Lo-Med-Hishy 399 533 533 Super Hi or Lo-Med-
WET 144-202shy109-134shy
144-202shy170-237shy 194-240shy
Fan Hi-Powerful)1 (CFM)
109-134-201-286-364 307-343
201-286shy350-367
300-385shy 304-385shy364 498 498
Airflow at Heating 145-170shy 145-170shy 145-170shy 205-247shy 230-275shy
(Quiet-Lo-Med-Hi- WET 233-321shy 237-321shy
166-240shy237-321shy
166-240shy304-367shy 339-431shy
Super Hi or Lo-Medshy (CFM) 406 406
367 -381 406
399-420 463 512
Hi-Powerful) 2 Sound Pressure Level at Cooling
19-22-30shy 26-32-38shy 28-33-38shy(Quiet-Lo-Med-Hi-Super Hi or Loshy dB(A) 19-22-30-37 -43 22-31-39-42
37-45 22-33-43-45
44-49 44-49Med-Hi-Powerful) 1
Sound Pressure Level at Heating 19-22-30shy 26-30-35shy 28-33-38shy
(Quiet-Lo-Med-Hi-Super Hi or Loshy dB(A) 19-22-30-37 -43 22-31-40-42 37-43
22-23-43-44 40-46 43-48
Med-Hi-Powerful) 2
I External Finish Color Munsell No 10Y 92 02
IWln 31 middot716
Dimension Unit 10 In 9 18 10-18 9middot18 10-18 9-18
IH In 11-58
I Weight Unit ILbs 22 27 22 27 22 I Field Drainpipe ~D lin 58 Remote Con-
Type Wireless Remote (Optional Wired Controller) troller
ITvpe B41QA Refrigerant ~s$ideOD lin 38 Pipe I Liquid Side 00 In 14
Connection IndoorOutdoor FlaredFlared
Method
1~
II 18000 22500
21600 27600
388-469shy 38$-469shy628-738 628-738
347-420shy 347-420shy562-661 562-661
388-469shy 388-469shy628-738 628-738
34-41-49-53 34-41-49-53
32-41-49-52 32-41-49-52
43-516
9-38
12-1316 37
58 38
MXZ-2B20NA is also compatible with the MSZ-A and MSZ-FD series indoor units NOTES Test conditions are based on AHRI 210240
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F(6deg C) 3 Indoor units receive power from outdoor units through field-supplied wiring
Specifications are subject to change without notice LIMITED WARRANTY Seven-year warranty on compressor Five-year warranty on parts For data on specific indoor unit combinations see page 21
SEZ DUCTED INDOOR UNIT (FOR MXZ-8 OUTDOOR UNITS)
I
Notes 1 Cooling-Indoor DS 80deg F(267deg C) WS 67deg F(194deg C) Outdoor DS 95deg F (35deg C) WS 75deg F(239deg C)
2 Heating-Indoor DS 70deg F(211 deg C) WS 60deg F(156deg C) Outdoor DS 47deg F (83deg C) WS 43deg F(61 deg C)
3 External static pressure is factory set to 006 WGAdjustable via the
1---------t---+-----L-------------1~---__I PAR-21MAA
1--_____----__________+-____---L____----~_____________1 4 Indoor units receive power
jE~~~~-------------r----1-----~-~~~~~~~~-----___1 from outdoor units through fieldsupplied interconnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven-year warranty on compressor Five-year
1---------------------+---+------------------------1 warranty on parts
~--__I_~----------+-------~l----------I For data on specific indoor unit combinations see page 21 - 23
I--~------+~-----------~----------r_------------I
- Reference page 17 for SEZ static performance curves
24 MITSUBISHI ELECTRIC
25-30-35-40 26-31-36-41 35-38-42-46
25-30-35-40 28-31-36-41 35-38-42-47
MFZ FLOORLOW WALL INDOOR UNIT (FOR middotMXZ-8 OUTDOOR UNITS)
------shy
-==
Airflow at Heating (CFM) 177-198-219-332 184-201-219-335 261-275-297-434
Voltage
Fan
Airflow at Cooling (Lo-Med-Hi-Super Hi)1
169-205-251-314 251-279-325-394
163-197-241-303 170-207-252-309 241-269-313-379
(Lo-Med-Hi-Super Hi) 2
SLZ CEILING-RECESSED INDOOR UNIT (FOR MXZ-8 OUTDOOR UNITS) EFFICIENCY RATINGS
Voltage
Fan
Galvanized-steel SheetsMunsell 64Y 89 04
Refrigerant Pipe
Model Indoor Unit Type SEER HSPF
MXZ-2B20NA-1
Non-dueted 18 89
Dueted and Non-dueted 1675 87
Dueted 155 85
MXZ-2B20NA-1 ENERGY STAR amp
TAX CREDIT 2 x MSZ-GE09NA 18 89
MXZ-3B24NA
lJon-dueted 175 93
Dueted and Non-dueted 1625 89
Dueted 150 85
MXZ-3B24NA ENERGY STAR amp
TAX CREDIT
2 x MSZ-GE06NA 1 x MSZ-GE09NA
175 93
MXZ-3B24NA ENERGY STAR amp
TAX CREDIT
2 x MSZ-GE06NA 1 x MSZ-GE12NA
175 93
MXZ-3B30NA
Non-dueted 175 105
Dueted and Non-dueted 16 100
Dueted 145 95
MXZ-4B36NA
Non-dueted 18 93
Dueted and Non-dueted 16 5 92
Dueted 150 9 0
MXZ-BB4BNA
Non-dueted 15 87
Dueted and Non-dueted 14B B8
Dueted 147 89
Connection IndoorOutdoor FlaredFlared
Method
Notes 1 Cooling-Indoor DB 80deg F(267deg C) WB 67deg F(194deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(239deg C) 2 Heating-Indoor DB 70deg F(21 1 deg C) WB 60deg F(156deg C) Outdoor DB 47deg F(83deg C) WB 43deg F(61 deg C) 3 Indoor units receive power from outdoor units through field supplied interconnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 25
Notes 1 Cooling-Indoor DB 80deg F(267deg C) WB 67deg F (194deg C) Outdoor DB 95deg F (35deg C)WB 75deg F (239deg C)
2 Heating-Indoor DB 70deg F(211deg C) WB 60deg F (156deg C) Outdoor DB 47 F (83deg C) WB 43deg F (61 deg C)
3 Indoor units receive power from outdoor units through field supplied interco(lnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven -year warranty on compressor Five-year warranty on parts
Presently there is no 1 1 system with the MFZ indoor unit
s c
N o J ro Vl
C ro n ~ n OJ t o J V)
M-SERIES RATING CONDITIONS
INDOOR INTAKE AIR TEMPERATURE
OUTDOOR INTAKE AIR TEMPERATURE
COOLING
MAXIMUM
95degF DB 71 degF WB (MU SUZ MXZ-2B20-13B243B304B36) 90degF DB 73degF WB (MUZY-GE MUZ-FE MUzy-D)
115degF DB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B24 3B304B368B48)
MINIMUM 67degF DB 57degF WB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B201 3B243B304B36)
14degF DB (MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B24 3B304B36) 23degF DB (MXZ-8B48) 6rF DB (MU)
MAXIMUM 80degF DB 6rF WB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B243B304B36)
75degF DB 65degF WB (MUZY-GE MUZY-GA24 MUZ-FE SUZ MXZ-2B20-1 3B243B304B36) 70degF DB (MXZ-8B48)
HEATING
MINIMUM 70degF DB 60degFWB (MUZ-GE MUZ-GA24 MUZ-D MUZ-FE SUZ MXZ-2B20-1 3B243B304B36)
-13degF DB -15degFWB (MUZ-FE) -4degF DB -5degF WB (SUZ MUZ-GE) 5degF DB 4degF WB (MUZ-GA24 MXZ-8B48NA) 6degF DB 5degF WB (MXZ-2B20-1 3B24 3B304B36) 14degF DB 13degFWB (MUZ-D)
MU units operate at intake air temperature down to 10deg Fwith the addition of an ICM-326HM-1 low temperature control
REFRIGERANT TUBING SETS
OPTIONAL ACCESSORIES
REFRIGERANT LINE LENGTH FLARE FLARE _INDOOR UNIT OUTDOOR UNIT
MS-A09WA MU-A09WA 35 MS-A12WA
65 MU-A12WA 35
MSY-GE09NA 65
MUY-GE09NA 40
MSY-GE12NA
65
MUY-GE12NA 65 40
MSY-GE15NA MUY-GE15NA 40
MSY-GE18NA
65
MUY-GE18NA 100 50
MSZ-GE09NA MUZ-GE09NA 65 40
MSZ-GE12NA MUZ-GE12NA 40
MSZ-GE15NA
65
MUZ-GE15NA 40
MSZ-GE18NA
65
MUZ-GE18NA 100 50
MSY-GE24NA MUY-GE24NA 100 50
MSZ-GE24NA MUZ-GE24NA 100 50
MSY-D30NA MUY-D30NA 100 50
MSZ-D30NA MUZ-D30NA 50
MSY-D36NA
100
MUY-D36NA 50
MSZ-D36NA
100
MUZ-D36NA 100 50
MSZ-FE09NA MUZ-FE09NA 40
MSZ-FE12NA
65
MUZ-FE12NA 40
MSZ-GE06091215NA MSZ-FE0912NA
65
MXZ-2B20NA-1 164 4933MFZ-KA0912NA SEZ-KD09 1215NA
MSZ-GE0609 121518NA MSZ-FE091218N MFZ-KA09 1218NA MXZ-3B24NA 164 4933 SEZ -KD09 12 15 18NA SLZ-KA09 12 15NA
MSZ-GE0609 121518NA MSZ-GA24NA MSZ-FE091218NA
MXZ-3B30NA 4933230MFZ-KA091218NA SEZ -KD09 121518NA SLZ-KA09 12 15NA
MSZ-GE0609121518NA MSZ-GE24NA MSZ-FE09 12 18NA
MXZ-4B36NA 230 4933MFZ-KA091218NA SEZ -KD09121518NA SLZ-KA09 12 15NA
MSZ-GE0609 12 15 18NA MSZ-GE24NA MSZ-FE09 12 18NA
MXZ-8B48NA 6698377MFZ-KA091218NA SEZ-KD09121518NA SLZ-KA09 12 15NA
PART NUMBER I USE WITH I DESCRIPTION
Port Adapters and Connection Pipes MAC-A454JP-E MXZ-Series Adapter 38 X12
MAC-A455JP-E MXZ-Series Adapter 12 X38
MAC-A456JP-E MXZ-Series Adapter 12 X58
MSDD-50AR-E MXZ-Series Branch Box Tee Distribution Pipe - Flare Connection between two branch boxes
MSDD-50BR-E MXZ-Series Branch Box Tee Distribution Pipe - Braze Connection between two branch boxes
PAC-493PI MXZ-Series Adapter 14 X38
PAC-SG76RJ-E MXZ-Series Adapter 38 X58
OPTIONAL ACCESSORIES CONTINUED ON NEXT PAGE
49 amp 66 applies to installations in which the outdoor unit is installed below indoor unit26 MITSUBISHI ELECTRIC
OPTIONAL ACCESSORIES (CONTINUED)
PART NUMBER USE WITH DESCRIPTION Control Options and Accessories
M21 JKO 307 M-Series Indoor Units Remote temperature sensor for M-Series indoor units
MAC-397IF-E
MAC-399IF-E
PAC-YU25HT
PAR-21 MM-G
M-Series INVERTER Units
M-Series INVERTER Units
SEZ-KD Indoor Units
Use with P-Series SEZ and for wired M-Series Controller
MA and contact terminal interface - Required to use PAR-21 MM wired wall mount controller with M-Series Systems
CMCN M-NET control adapter I Interface for Mr Slim M-Series MSYZ SEZ I MFZ
External Fan I Heater control relay adapter
Deluxe MA remote controller (Requires MAC-397IF-E for use with M-Series - MSYZ MFZ)
SEZ Wireless remote controller for SEZ units (Requires signal receiver PAR-SA9FA-E)PAR-FL32MA
PAR-SA9CA-E SEZ Wireless signal receiver for SEZ
3-pole disconnect switch 30A 600V turns off power between indoor and outdoor units shyM-SeriesTAZ-MS303
mounts in 2 X 4 utility box and requires standard single gang switch platecover - Low Ambient
ICM-326HM-2 M-Series Non-INVERTER units Low ambient head pressure controller MUZ-GE091215 IVIUZ-FE0912 SUZ-KD091215
Drain pan heaterMAC-640BH-U outdoor unit
MAC-641 BH-U MUZ-GE18 SUZ-KD18 outdoor unit Drain pan heater Filters
MAC-1415FT-E Anti-allergy enzyme filter
MAC-2300FT
MSZlMSY-D3036
Anti -allergy enzyme filter
MAC-308FT
MSYMSZ-GA24
MSZ-FD912 I FE0912 Platinum deodorizing filter
MAC-408FT-E Anti-allergy enzyme filter
MAC-415FT-E
M-Series Indoor Unit - GE09GE12GE15GE18
MFZ-KA Air Cleaning FilterAnti-Aliergy Enzyme Filter
MAC-418FT Anti-allergy enzyme filter
Filter Boxes
FBL1-1
MSZ- FD912 I FE091 2
FB Series Filter Box for SEZ-KD09NA Optional filter box with MERV 8 filters
FB Series Filter Box for SEZ-KD1215NAFBL1-2 Optional filter box with MERV 8 filters
and PEA-A 12M
FBL1-3 FB Series Filter Box for SEZ-KD18NA Optional filter box with MERV 8 filters
Pumps
SI1730-230 MSYZ - 30000 Btuh or greater Sauermann mini condensation pump 230V
S13100-115 MS-Series - non-INVERTER Sauermann mini condensation pump 115V
S13100-230 Sauermann mini condensation pump 230VMSYZ - Less than 30000 Btuh
Miscellaneous BRP-1 Bottom Return Plate for SEZ-KD09NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-2 Bottom Return Plate for SEZ-KD12KD15-NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-3 Bottom Return Plate for SEZ-KD18NA Converts low profile ducted indoor unit from rear return to bottom return
BV12FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderreglnsulated - 12
BV14FSI Use with any Mr Sl im multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 14
BV38FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 38
BV58FSI Use with any IVIr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 58
Condensing unit wall mounting brackets (set of 2) - 440 lb capacity painted steel NOTE CWMB1 IVIU and PU outdoor units Installer is responsible to select and provide suitable hardware and materials to insure proper
mount of bracket to wall
DSD-400N M-Series DiamondBacktrade Platform Stands MUZ-GE18 I MUZ(y)-03036 I
MAC-811DS Drain socket assemblySUZ-KA18
MAC-851DS MUZ-FD0912 Drain socket
MAC-855SG M-Series Air outlet guide
MAC-856SG M-Series Air outlet guide - MXZ-3B24 I 3B30 I 4B36 NA
MAC-860DS MUZ-GE091215 I MUZ-FE0912 Drain socket
MAC-889SG M-Series Air outlet guide- MXZ-2B20NA
MAC-S99SG M-Series Air outlet guide
PAC-SG59SG-E IVIXZ-SB4SNA Air outlet guide (1 piece) I MXZ-SB48NA (Requires 2 pieces)
PAC-SG61 DS-E MXZ-8B4SNA Drain socket - connector
PAC-SG64DP-E MXZ-SB48NA Drain pan
RCMKP1CB lVI-Series Wireless Lockdown bracket for remote controller
lILTRILlTE1 All M-Series Condensing unit mounting pad 16 x 36 x 3
MITSUBISHI ELECTRIC 27
MXZ-8 Series Port Adapter chart Port Adapter Unit Port
Combinations Required Size
MXZ-2B20NA-1
2-zone combinations wi NA
A 38 x both units s12K 14
1-MAC-A454JP-E B 38 x
6+15 14
9+15 1-MAC-A454JP-E
MXZ-3B24NA
All rated 2-zone combina-NA
A 12 x tions 14
All rated 3-zone combina-NA
B 38 x tions 14
C 38 x 14
MXZ-3B30NA
2-zone combinations wi at NA
A 12 x least one unit s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
9 + 24 14
3-zone combinations wi 1-MAC-A455JP-E
all units s12K
All other rated 3-zone NA
comb
MXZ-4B36NA
2-zone combinations wi at NA
A 12 x least one un it s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
6 + 24 14
1-MAC-A456JP-E D 38 x
9 + 24 14
3-zone combinations wi at NA
least two units s12K
3-zone combinations wi 1-MAC-A454JP-E
two units15K
6+6+24 or 6+9+24 1-MAC-A456JP-E
9+9+24 1-MAC-A456JP-E
4-zone combinations wi at 1-MAC-A455JP-E
least three units s12K
6+6+15+15 1-MAC-A454JP-E
6+6+15+15 1-MAC-A454JP-E
Note When using the Pu-A24BA PCA-A24KA or PEAD-A24AA two port adapter will be needed 1-MAC-A456JP-E (12 x 58) A port or 1-PACshySG76RJ-E (38 x 58) B C and D ports and 1-PAC493PI (14 x 38)
28 JMITSUBISHI ELECTRIC
6+6+246+9+24 6+12+249+9+24 9+12+24 or 12+12+24
6+15+24 6+18+24 9+15+249+18+24 12+15+24 or 12+18+24
15+15+24 15+18+24 or 18+18+24
15+24+24 or 18+24+24
Combinations of 4 or more zones
1-PAC-SG76RJ-E
See notes for application below
2
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
See notes for application below
PORT A =38 gas x 14 liquid
PORT B =38 gas x 14 liquid
PORT C =38 gas x 14 liquid
PORT A =38 gas x 14 liquid
PORT B = 38 gas x 14 liquid
PORT C = 38 gas x 14 liquid
PORT D =38 gas x 14 liquid
PORT E =12 gas x 14 liquid
Notes for application bull Check the lineset sizes for your indoor selected models bull Select the branch box or boxes needed for your application bull Compare indoor unit lineset sizes as compared to branch
box sizes bull Connect 15K + indoor units to the larger port on the
(PAC-AKA51 BC) bull Adapt lineset size with appropriate port adapter from
above list bull When using the PU-A24BA or PEAD-A24AA two port
adapter will be needed 1-MAC-A456JP-E (12 x 58) or 1-PAC-SG76RJ-E (38 x 58) and 1-PAC493PI (14 x 38)
-fv
~ DIAMONDBACKtrade
~) BV-Series Ball Valves Model numbers
BV14FFSI BV38FFSI
LISTED 891N REFRIGERANT
BV12FFSI VALVE bull Engineered for Mini-split andBV58FFSI
Multi-split HVAC Units bull Size available 14 38 12 58
bull Full Port Designbull Fully factory assembled bull Furnace brazed and pressure tested bull 700 PSIG Rated bull Each ball valve is equipped with Schraderreg Valve
for refrigerant service bull R-410A Compatible bull Design working pressure 700 PSIG bull Temperature range bull Flare Connections
-40 0 F to +3250 F (-400 C to + 1490
C) bull Forged brass body and seal cap bull Teflonreg seals and gaskets (no synthetic a-rings) bull Seal cap design permits valve operation without
removal of seal cap bull Suitable for use with R-11 R-22 R-123 R-125
R-134A R-236FA R-4202A R-402B R-404A R-407C R-410A R-500 R-502 and R-507
bull One year limited materials and workmanship
Part Number SAE Flare
A B C 0 E F
BV14FFSI 14 619 260 180 122 142 110
BV38FFSI 38 630 267 180 122 142 110
BV12FFSI 12 651 267 180 122 142 110
BV58FFSI 58 664 267 180 128 142 110
Ball valves come With an insulation piece warranty on Ball Valves
~ DIAMONDBACKtrade
~) Platform Stands
Lift the Mitsubishi Electric Comfort Solution
outdoor unit to new heights with our Diamondback Platform Stands
bull Easy to install
bull Available for all sizes of Mr Slim outdoor units
bull Color matched to the outdoor units
Model Number DSD-400N
L 15-34 x W 3-14 x H 3-14
r
)MITSUBISHI ELECTRIC 29
~ DIAMONDBACKtrade LINESETS
~~
Twin-Tube Lineset Insulation Design
bull Balanced outside diameter for uniform coiluncoil position stability
bull Minimum 12 insulation thickness on both tubes Diamondback Advantages include the following features
bull Quick efficient and economical field installation using factory applied Twin Tube insulation and flare connections with flare nuts mounted
bull Correct lengths for reducing waste and time
bull Quality consistency and economy
bull All Diamondback Lineset tubing is tested in accordance with ASTM E243
Filter Boxes
FB Series filter boxes are available in compatible sizes for all Mr Slim horizontal ducted indoor units
FBL 1 filter boxes include 1 thick pleated MERV 8 filter(s) installed Filters are tested in accordance with ANSIASHRAE Standard 522 and Rated Class 2 under UL Standard 900
The cabinet is constructed of non-insulated 20 gauge G-60 galvanized
FBL1-1 FB Series Filter Box for SEZ-KD09NA
FBL1-2 FB Series Filter Box for SEZ-KD12KD15-NA
FBL1-3 FB Series Filter Box for SEZ-KD18NA
steel with foam gasket and provides an air-tight connection to indoor unit and access door Gasket material complies with UL 723 requirements
A screw-through cabinet design for secure attachment to indoor unit and return connection in rear is easily field-converted to bottom return
30 MITSUBISHI ELECTRIC
bull
bull
bull
bull
bull
bull
LINE-HIDE~ Put a professional finish on air-conditioning
installations with an easy-to-install modular
system that beautifies exteriors and
protects Linesets drainlines and wiring
Can be use it indoors too Meets UL94v-O for interior applications
Has snap-on covers and a full selection of couplings elbows T-joints caps and more for any application complex or simple
Offers high-quality PVC with UV inhibitors for outdoor service in all weather conditions
Can be painted with most house paints to match exterior decors
Is not just for HVAC Hide any exterior cabling piping or wiring
Available in four sizes 2-14 3 4 and 6 tubes
Download a brochure at wwwline-hidecom to find out more information
For more information on our CITY MULTI VRF product line visit our website at wwwmitsubishiprocom
_lIJrUlllln ~ ~IIII1 fInll l
~
l bull bull
JMITSUBISHI ELECTRIC 31
I
RMULTI-ROOM MXZ-8 INVERTER HEAT PUMP
Model Name Outdoor Unit MXZ-BB4BNA Cooling 1 Rated Capacity
Non-ducted Rated Total Input Ducted
Maximum Capacity
Rated CapacityHeating at
Rated Total InputIndoor Unit 4JO F 2 Non-
ductedDucted Maximum Capacity
Rated Capacity Heating at
Rated Total InputlJO F 3 Non-ductedDucted Maximum Capacity
Power Supply Phase Cycle Voltage
Indoor - Outdoor Sl - S2 Voltage
Indoor - Outdoor S2 - S3
MCA
Recommended FuseBreaker Size
Fan Motor
Compressor
Airflow (CoolingHeating)
Refrigerant Control
Outdoor Unit Sound Pressure Level at Cooling 1
Sound Pressure Level at Heating 2
External Finish Color
Dimensions
Weight
Total Capacity 22-130
Indoor Unit ModelQuantity
Remote Controller Type
Type
Refrigerant Charge
Oil
Gas Side OD Refrigerant Pipe
Liquid Side OD
Height Difference (Max)
Maximum Distance between (Outdoor unit and farthest indoor unit)
Refrigerant Pipe Length Maximum Pipe Length -Branch box to Indoor Unit
Total Maximum line length between Branch Box and All Connected Indoor Units
Total Length (Max)
Connection Method IndoorOutdoor
Includes both branch boxes if there are two
Branch Boxes (At least one branch box required)
Btuh
W
Btuh
Btuh
W
Btuh
Btuh
W
Btuh
A
A
Type x Quantity
Motor Output (kW)
Model (Type)
Motor Output (kW)
CFM
dB(A)
dB(A)
W In
D In
H In
Lbs
Btuh
Lbs Oz
Type (fl oz)
In
In
Ft
Ft
Ft
Ft
Ft
4800048000
57806470
54000
5400054000
48205270
60000
3300034700
29503390
3660036550
1 Phase 60Hz 208 230V
AC 208-230V
DC12-24V
32
40
Propeller x 2
0086 + 0086
DC INVERTER-driven Scroll
29
3530
Linear Expansion Valve
54
55
Munsell No 3Y 78 11
37-716
13+1-3 16
53-3 16
278
12000 - 70200
600 - 24000 2-8
Associated with Indoor Unit Model
R410A
18 112
FV50S (73)
58
38
6698 4
230
49
197
377
FlaredFlared
Compatible with the MSZ-A MSZ-FO MSZ-FE MSZ-GE MFZ-KA SEZ-KD PLA and PEAD series indoor units
NOTES Test conditions are based on AHRI 210240 One indoor unit is turned off during low-speed testing under the new test conditions Systems actually exhibit higher energy efficiencies during normal operation
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F (35deg C) WB 75deg F (24deg C)
2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 4]0 F (8deg C) WB 43deg F (6deg C)
3 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F (16deg C) Outdoor DB 17deg F (-8deg C) WB 15deg F(-9deg C)
4 66 applies to installations when the outdoor unit is installed below the indoor unit
Power factor equals 97 percent
Specifications are subject to change without notice
Note Maximum installed capacity is the maximum total of all connected indoor units NOT the maximum capacity produced
Only a single Lineset is needed from the outdoor unit to branch box
See page 25 for MXZ-B information on efficiency
Required Branch Boxes for MXZ-SB4BNA (Maximum of 2 branch boxes can be connected to one outdoor unit requires joint MSDD-50AR-E or MSDD-50BR-E)
s c d N o J ro Vl
0 ro n 3i n OJ d o J U)
PAC-AKA51 BC Branch Box
PAC-AKA31 BC Branch Box LIMITED WARRANTY I Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 23
MSZ WALL-MOUNTED INDOOR UNITS (FOR MXZ-8 OUTDOOR UNITS)
R
(MSZ-GE12NA MODEL SHOWN)
-000 IIIIIII 9000 9000 12000 12000 14000 17200
Heating at 4r Rated Capacity Btuh 7200 10900 10900 14400 13600 18000 21600
F2 Power Supply I Phase Cycle Voltage J -phase 60Hz 208 230V 3
Iindoor Outdoor S1 S2 AC 208 230V
Iindoor Outdoor S2 S3 DC12-24V Voltage
Iindoor Remote vomr Iller Wireless Type (Optional Wired vomroller DC 12V)
IMCA A 10 IFan Motor FLA 076
DRY 162-226shy145-170shy
162-226shy205-272shy 230-275shy
Airflow at Cooling (CFM)
145-170-237-321-399 339-381
237 -321shy381-410
335-420shy 339-420shy(Quiet-Lo-Med-Hishy 399 533 533 Super Hi or Lo-Med-
WET 144-202shy109-134shy
144-202shy170-237shy 194-240shy
Fan Hi-Powerful)1 (CFM)
109-134-201-286-364 307-343
201-286shy350-367
300-385shy 304-385shy364 498 498
Airflow at Heating 145-170shy 145-170shy 145-170shy 205-247shy 230-275shy
(Quiet-Lo-Med-Hi- WET 233-321shy 237-321shy
166-240shy237-321shy
166-240shy304-367shy 339-431shy
Super Hi or Lo-Medshy (CFM) 406 406
367 -381 406
399-420 463 512
Hi-Powerful) 2 Sound Pressure Level at Cooling
19-22-30shy 26-32-38shy 28-33-38shy(Quiet-Lo-Med-Hi-Super Hi or Loshy dB(A) 19-22-30-37 -43 22-31-39-42
37-45 22-33-43-45
44-49 44-49Med-Hi-Powerful) 1
Sound Pressure Level at Heating 19-22-30shy 26-30-35shy 28-33-38shy
(Quiet-Lo-Med-Hi-Super Hi or Loshy dB(A) 19-22-30-37 -43 22-31-40-42 37-43
22-23-43-44 40-46 43-48
Med-Hi-Powerful) 2
I External Finish Color Munsell No 10Y 92 02
IWln 31 middot716
Dimension Unit 10 In 9 18 10-18 9middot18 10-18 9-18
IH In 11-58
I Weight Unit ILbs 22 27 22 27 22 I Field Drainpipe ~D lin 58 Remote Con-
Type Wireless Remote (Optional Wired Controller) troller
ITvpe B41QA Refrigerant ~s$ideOD lin 38 Pipe I Liquid Side 00 In 14
Connection IndoorOutdoor FlaredFlared
Method
1~
II 18000 22500
21600 27600
388-469shy 38$-469shy628-738 628-738
347-420shy 347-420shy562-661 562-661
388-469shy 388-469shy628-738 628-738
34-41-49-53 34-41-49-53
32-41-49-52 32-41-49-52
43-516
9-38
12-1316 37
58 38
MXZ-2B20NA is also compatible with the MSZ-A and MSZ-FD series indoor units NOTES Test conditions are based on AHRI 210240
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F(6deg C) 3 Indoor units receive power from outdoor units through field-supplied wiring
Specifications are subject to change without notice LIMITED WARRANTY Seven-year warranty on compressor Five-year warranty on parts For data on specific indoor unit combinations see page 21
SEZ DUCTED INDOOR UNIT (FOR MXZ-8 OUTDOOR UNITS)
I
Notes 1 Cooling-Indoor DS 80deg F(267deg C) WS 67deg F(194deg C) Outdoor DS 95deg F (35deg C) WS 75deg F(239deg C)
2 Heating-Indoor DS 70deg F(211 deg C) WS 60deg F(156deg C) Outdoor DS 47deg F (83deg C) WS 43deg F(61 deg C)
3 External static pressure is factory set to 006 WGAdjustable via the
1---------t---+-----L-------------1~---__I PAR-21MAA
1--_____----__________+-____---L____----~_____________1 4 Indoor units receive power
jE~~~~-------------r----1-----~-~~~~~~~~-----___1 from outdoor units through fieldsupplied interconnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven-year warranty on compressor Five-year
1---------------------+---+------------------------1 warranty on parts
~--__I_~----------+-------~l----------I For data on specific indoor unit combinations see page 21 - 23
I--~------+~-----------~----------r_------------I
- Reference page 17 for SEZ static performance curves
24 MITSUBISHI ELECTRIC
25-30-35-40 26-31-36-41 35-38-42-46
25-30-35-40 28-31-36-41 35-38-42-47
MFZ FLOORLOW WALL INDOOR UNIT (FOR middotMXZ-8 OUTDOOR UNITS)
------shy
-==
Airflow at Heating (CFM) 177-198-219-332 184-201-219-335 261-275-297-434
Voltage
Fan
Airflow at Cooling (Lo-Med-Hi-Super Hi)1
169-205-251-314 251-279-325-394
163-197-241-303 170-207-252-309 241-269-313-379
(Lo-Med-Hi-Super Hi) 2
SLZ CEILING-RECESSED INDOOR UNIT (FOR MXZ-8 OUTDOOR UNITS) EFFICIENCY RATINGS
Voltage
Fan
Galvanized-steel SheetsMunsell 64Y 89 04
Refrigerant Pipe
Model Indoor Unit Type SEER HSPF
MXZ-2B20NA-1
Non-dueted 18 89
Dueted and Non-dueted 1675 87
Dueted 155 85
MXZ-2B20NA-1 ENERGY STAR amp
TAX CREDIT 2 x MSZ-GE09NA 18 89
MXZ-3B24NA
lJon-dueted 175 93
Dueted and Non-dueted 1625 89
Dueted 150 85
MXZ-3B24NA ENERGY STAR amp
TAX CREDIT
2 x MSZ-GE06NA 1 x MSZ-GE09NA
175 93
MXZ-3B24NA ENERGY STAR amp
TAX CREDIT
2 x MSZ-GE06NA 1 x MSZ-GE12NA
175 93
MXZ-3B30NA
Non-dueted 175 105
Dueted and Non-dueted 16 100
Dueted 145 95
MXZ-4B36NA
Non-dueted 18 93
Dueted and Non-dueted 16 5 92
Dueted 150 9 0
MXZ-BB4BNA
Non-dueted 15 87
Dueted and Non-dueted 14B B8
Dueted 147 89
Connection IndoorOutdoor FlaredFlared
Method
Notes 1 Cooling-Indoor DB 80deg F(267deg C) WB 67deg F(194deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(239deg C) 2 Heating-Indoor DB 70deg F(21 1 deg C) WB 60deg F(156deg C) Outdoor DB 47deg F(83deg C) WB 43deg F(61 deg C) 3 Indoor units receive power from outdoor units through field supplied interconnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 25
Notes 1 Cooling-Indoor DB 80deg F(267deg C) WB 67deg F (194deg C) Outdoor DB 95deg F (35deg C)WB 75deg F (239deg C)
2 Heating-Indoor DB 70deg F(211deg C) WB 60deg F (156deg C) Outdoor DB 47 F (83deg C) WB 43deg F (61 deg C)
3 Indoor units receive power from outdoor units through field supplied interco(lnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven -year warranty on compressor Five-year warranty on parts
Presently there is no 1 1 system with the MFZ indoor unit
s c
N o J ro Vl
C ro n ~ n OJ t o J V)
M-SERIES RATING CONDITIONS
INDOOR INTAKE AIR TEMPERATURE
OUTDOOR INTAKE AIR TEMPERATURE
COOLING
MAXIMUM
95degF DB 71 degF WB (MU SUZ MXZ-2B20-13B243B304B36) 90degF DB 73degF WB (MUZY-GE MUZ-FE MUzy-D)
115degF DB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B24 3B304B368B48)
MINIMUM 67degF DB 57degF WB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B201 3B243B304B36)
14degF DB (MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B24 3B304B36) 23degF DB (MXZ-8B48) 6rF DB (MU)
MAXIMUM 80degF DB 6rF WB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B243B304B36)
75degF DB 65degF WB (MUZY-GE MUZY-GA24 MUZ-FE SUZ MXZ-2B20-1 3B243B304B36) 70degF DB (MXZ-8B48)
HEATING
MINIMUM 70degF DB 60degFWB (MUZ-GE MUZ-GA24 MUZ-D MUZ-FE SUZ MXZ-2B20-1 3B243B304B36)
-13degF DB -15degFWB (MUZ-FE) -4degF DB -5degF WB (SUZ MUZ-GE) 5degF DB 4degF WB (MUZ-GA24 MXZ-8B48NA) 6degF DB 5degF WB (MXZ-2B20-1 3B24 3B304B36) 14degF DB 13degFWB (MUZ-D)
MU units operate at intake air temperature down to 10deg Fwith the addition of an ICM-326HM-1 low temperature control
REFRIGERANT TUBING SETS
OPTIONAL ACCESSORIES
REFRIGERANT LINE LENGTH FLARE FLARE _INDOOR UNIT OUTDOOR UNIT
MS-A09WA MU-A09WA 35 MS-A12WA
65 MU-A12WA 35
MSY-GE09NA 65
MUY-GE09NA 40
MSY-GE12NA
65
MUY-GE12NA 65 40
MSY-GE15NA MUY-GE15NA 40
MSY-GE18NA
65
MUY-GE18NA 100 50
MSZ-GE09NA MUZ-GE09NA 65 40
MSZ-GE12NA MUZ-GE12NA 40
MSZ-GE15NA
65
MUZ-GE15NA 40
MSZ-GE18NA
65
MUZ-GE18NA 100 50
MSY-GE24NA MUY-GE24NA 100 50
MSZ-GE24NA MUZ-GE24NA 100 50
MSY-D30NA MUY-D30NA 100 50
MSZ-D30NA MUZ-D30NA 50
MSY-D36NA
100
MUY-D36NA 50
MSZ-D36NA
100
MUZ-D36NA 100 50
MSZ-FE09NA MUZ-FE09NA 40
MSZ-FE12NA
65
MUZ-FE12NA 40
MSZ-GE06091215NA MSZ-FE0912NA
65
MXZ-2B20NA-1 164 4933MFZ-KA0912NA SEZ-KD09 1215NA
MSZ-GE0609 121518NA MSZ-FE091218N MFZ-KA09 1218NA MXZ-3B24NA 164 4933 SEZ -KD09 12 15 18NA SLZ-KA09 12 15NA
MSZ-GE0609 121518NA MSZ-GA24NA MSZ-FE091218NA
MXZ-3B30NA 4933230MFZ-KA091218NA SEZ -KD09 121518NA SLZ-KA09 12 15NA
MSZ-GE0609121518NA MSZ-GE24NA MSZ-FE09 12 18NA
MXZ-4B36NA 230 4933MFZ-KA091218NA SEZ -KD09121518NA SLZ-KA09 12 15NA
MSZ-GE0609 12 15 18NA MSZ-GE24NA MSZ-FE09 12 18NA
MXZ-8B48NA 6698377MFZ-KA091218NA SEZ-KD09121518NA SLZ-KA09 12 15NA
PART NUMBER I USE WITH I DESCRIPTION
Port Adapters and Connection Pipes MAC-A454JP-E MXZ-Series Adapter 38 X12
MAC-A455JP-E MXZ-Series Adapter 12 X38
MAC-A456JP-E MXZ-Series Adapter 12 X58
MSDD-50AR-E MXZ-Series Branch Box Tee Distribution Pipe - Flare Connection between two branch boxes
MSDD-50BR-E MXZ-Series Branch Box Tee Distribution Pipe - Braze Connection between two branch boxes
PAC-493PI MXZ-Series Adapter 14 X38
PAC-SG76RJ-E MXZ-Series Adapter 38 X58
OPTIONAL ACCESSORIES CONTINUED ON NEXT PAGE
49 amp 66 applies to installations in which the outdoor unit is installed below indoor unit26 MITSUBISHI ELECTRIC
OPTIONAL ACCESSORIES (CONTINUED)
PART NUMBER USE WITH DESCRIPTION Control Options and Accessories
M21 JKO 307 M-Series Indoor Units Remote temperature sensor for M-Series indoor units
MAC-397IF-E
MAC-399IF-E
PAC-YU25HT
PAR-21 MM-G
M-Series INVERTER Units
M-Series INVERTER Units
SEZ-KD Indoor Units
Use with P-Series SEZ and for wired M-Series Controller
MA and contact terminal interface - Required to use PAR-21 MM wired wall mount controller with M-Series Systems
CMCN M-NET control adapter I Interface for Mr Slim M-Series MSYZ SEZ I MFZ
External Fan I Heater control relay adapter
Deluxe MA remote controller (Requires MAC-397IF-E for use with M-Series - MSYZ MFZ)
SEZ Wireless remote controller for SEZ units (Requires signal receiver PAR-SA9FA-E)PAR-FL32MA
PAR-SA9CA-E SEZ Wireless signal receiver for SEZ
3-pole disconnect switch 30A 600V turns off power between indoor and outdoor units shyM-SeriesTAZ-MS303
mounts in 2 X 4 utility box and requires standard single gang switch platecover - Low Ambient
ICM-326HM-2 M-Series Non-INVERTER units Low ambient head pressure controller MUZ-GE091215 IVIUZ-FE0912 SUZ-KD091215
Drain pan heaterMAC-640BH-U outdoor unit
MAC-641 BH-U MUZ-GE18 SUZ-KD18 outdoor unit Drain pan heater Filters
MAC-1415FT-E Anti-allergy enzyme filter
MAC-2300FT
MSZlMSY-D3036
Anti -allergy enzyme filter
MAC-308FT
MSYMSZ-GA24
MSZ-FD912 I FE0912 Platinum deodorizing filter
MAC-408FT-E Anti-allergy enzyme filter
MAC-415FT-E
M-Series Indoor Unit - GE09GE12GE15GE18
MFZ-KA Air Cleaning FilterAnti-Aliergy Enzyme Filter
MAC-418FT Anti-allergy enzyme filter
Filter Boxes
FBL1-1
MSZ- FD912 I FE091 2
FB Series Filter Box for SEZ-KD09NA Optional filter box with MERV 8 filters
FB Series Filter Box for SEZ-KD1215NAFBL1-2 Optional filter box with MERV 8 filters
and PEA-A 12M
FBL1-3 FB Series Filter Box for SEZ-KD18NA Optional filter box with MERV 8 filters
Pumps
SI1730-230 MSYZ - 30000 Btuh or greater Sauermann mini condensation pump 230V
S13100-115 MS-Series - non-INVERTER Sauermann mini condensation pump 115V
S13100-230 Sauermann mini condensation pump 230VMSYZ - Less than 30000 Btuh
Miscellaneous BRP-1 Bottom Return Plate for SEZ-KD09NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-2 Bottom Return Plate for SEZ-KD12KD15-NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-3 Bottom Return Plate for SEZ-KD18NA Converts low profile ducted indoor unit from rear return to bottom return
BV12FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderreglnsulated - 12
BV14FSI Use with any Mr Sl im multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 14
BV38FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 38
BV58FSI Use with any IVIr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 58
Condensing unit wall mounting brackets (set of 2) - 440 lb capacity painted steel NOTE CWMB1 IVIU and PU outdoor units Installer is responsible to select and provide suitable hardware and materials to insure proper
mount of bracket to wall
DSD-400N M-Series DiamondBacktrade Platform Stands MUZ-GE18 I MUZ(y)-03036 I
MAC-811DS Drain socket assemblySUZ-KA18
MAC-851DS MUZ-FD0912 Drain socket
MAC-855SG M-Series Air outlet guide
MAC-856SG M-Series Air outlet guide - MXZ-3B24 I 3B30 I 4B36 NA
MAC-860DS MUZ-GE091215 I MUZ-FE0912 Drain socket
MAC-889SG M-Series Air outlet guide- MXZ-2B20NA
MAC-S99SG M-Series Air outlet guide
PAC-SG59SG-E IVIXZ-SB4SNA Air outlet guide (1 piece) I MXZ-SB48NA (Requires 2 pieces)
PAC-SG61 DS-E MXZ-8B4SNA Drain socket - connector
PAC-SG64DP-E MXZ-SB48NA Drain pan
RCMKP1CB lVI-Series Wireless Lockdown bracket for remote controller
lILTRILlTE1 All M-Series Condensing unit mounting pad 16 x 36 x 3
MITSUBISHI ELECTRIC 27
MXZ-8 Series Port Adapter chart Port Adapter Unit Port
Combinations Required Size
MXZ-2B20NA-1
2-zone combinations wi NA
A 38 x both units s12K 14
1-MAC-A454JP-E B 38 x
6+15 14
9+15 1-MAC-A454JP-E
MXZ-3B24NA
All rated 2-zone combina-NA
A 12 x tions 14
All rated 3-zone combina-NA
B 38 x tions 14
C 38 x 14
MXZ-3B30NA
2-zone combinations wi at NA
A 12 x least one unit s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
9 + 24 14
3-zone combinations wi 1-MAC-A455JP-E
all units s12K
All other rated 3-zone NA
comb
MXZ-4B36NA
2-zone combinations wi at NA
A 12 x least one un it s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
6 + 24 14
1-MAC-A456JP-E D 38 x
9 + 24 14
3-zone combinations wi at NA
least two units s12K
3-zone combinations wi 1-MAC-A454JP-E
two units15K
6+6+24 or 6+9+24 1-MAC-A456JP-E
9+9+24 1-MAC-A456JP-E
4-zone combinations wi at 1-MAC-A455JP-E
least three units s12K
6+6+15+15 1-MAC-A454JP-E
6+6+15+15 1-MAC-A454JP-E
Note When using the Pu-A24BA PCA-A24KA or PEAD-A24AA two port adapter will be needed 1-MAC-A456JP-E (12 x 58) A port or 1-PACshySG76RJ-E (38 x 58) B C and D ports and 1-PAC493PI (14 x 38)
28 JMITSUBISHI ELECTRIC
6+6+246+9+24 6+12+249+9+24 9+12+24 or 12+12+24
6+15+24 6+18+24 9+15+249+18+24 12+15+24 or 12+18+24
15+15+24 15+18+24 or 18+18+24
15+24+24 or 18+24+24
Combinations of 4 or more zones
1-PAC-SG76RJ-E
See notes for application below
2
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
See notes for application below
PORT A =38 gas x 14 liquid
PORT B =38 gas x 14 liquid
PORT C =38 gas x 14 liquid
PORT A =38 gas x 14 liquid
PORT B = 38 gas x 14 liquid
PORT C = 38 gas x 14 liquid
PORT D =38 gas x 14 liquid
PORT E =12 gas x 14 liquid
Notes for application bull Check the lineset sizes for your indoor selected models bull Select the branch box or boxes needed for your application bull Compare indoor unit lineset sizes as compared to branch
box sizes bull Connect 15K + indoor units to the larger port on the
(PAC-AKA51 BC) bull Adapt lineset size with appropriate port adapter from
above list bull When using the PU-A24BA or PEAD-A24AA two port
adapter will be needed 1-MAC-A456JP-E (12 x 58) or 1-PAC-SG76RJ-E (38 x 58) and 1-PAC493PI (14 x 38)
-fv
~ DIAMONDBACKtrade
~) BV-Series Ball Valves Model numbers
BV14FFSI BV38FFSI
LISTED 891N REFRIGERANT
BV12FFSI VALVE bull Engineered for Mini-split andBV58FFSI
Multi-split HVAC Units bull Size available 14 38 12 58
bull Full Port Designbull Fully factory assembled bull Furnace brazed and pressure tested bull 700 PSIG Rated bull Each ball valve is equipped with Schraderreg Valve
for refrigerant service bull R-410A Compatible bull Design working pressure 700 PSIG bull Temperature range bull Flare Connections
-40 0 F to +3250 F (-400 C to + 1490
C) bull Forged brass body and seal cap bull Teflonreg seals and gaskets (no synthetic a-rings) bull Seal cap design permits valve operation without
removal of seal cap bull Suitable for use with R-11 R-22 R-123 R-125
R-134A R-236FA R-4202A R-402B R-404A R-407C R-410A R-500 R-502 and R-507
bull One year limited materials and workmanship
Part Number SAE Flare
A B C 0 E F
BV14FFSI 14 619 260 180 122 142 110
BV38FFSI 38 630 267 180 122 142 110
BV12FFSI 12 651 267 180 122 142 110
BV58FFSI 58 664 267 180 128 142 110
Ball valves come With an insulation piece warranty on Ball Valves
~ DIAMONDBACKtrade
~) Platform Stands
Lift the Mitsubishi Electric Comfort Solution
outdoor unit to new heights with our Diamondback Platform Stands
bull Easy to install
bull Available for all sizes of Mr Slim outdoor units
bull Color matched to the outdoor units
Model Number DSD-400N
L 15-34 x W 3-14 x H 3-14
r
)MITSUBISHI ELECTRIC 29
~ DIAMONDBACKtrade LINESETS
~~
Twin-Tube Lineset Insulation Design
bull Balanced outside diameter for uniform coiluncoil position stability
bull Minimum 12 insulation thickness on both tubes Diamondback Advantages include the following features
bull Quick efficient and economical field installation using factory applied Twin Tube insulation and flare connections with flare nuts mounted
bull Correct lengths for reducing waste and time
bull Quality consistency and economy
bull All Diamondback Lineset tubing is tested in accordance with ASTM E243
Filter Boxes
FB Series filter boxes are available in compatible sizes for all Mr Slim horizontal ducted indoor units
FBL 1 filter boxes include 1 thick pleated MERV 8 filter(s) installed Filters are tested in accordance with ANSIASHRAE Standard 522 and Rated Class 2 under UL Standard 900
The cabinet is constructed of non-insulated 20 gauge G-60 galvanized
FBL1-1 FB Series Filter Box for SEZ-KD09NA
FBL1-2 FB Series Filter Box for SEZ-KD12KD15-NA
FBL1-3 FB Series Filter Box for SEZ-KD18NA
steel with foam gasket and provides an air-tight connection to indoor unit and access door Gasket material complies with UL 723 requirements
A screw-through cabinet design for secure attachment to indoor unit and return connection in rear is easily field-converted to bottom return
30 MITSUBISHI ELECTRIC
bull
bull
bull
bull
bull
bull
LINE-HIDE~ Put a professional finish on air-conditioning
installations with an easy-to-install modular
system that beautifies exteriors and
protects Linesets drainlines and wiring
Can be use it indoors too Meets UL94v-O for interior applications
Has snap-on covers and a full selection of couplings elbows T-joints caps and more for any application complex or simple
Offers high-quality PVC with UV inhibitors for outdoor service in all weather conditions
Can be painted with most house paints to match exterior decors
Is not just for HVAC Hide any exterior cabling piping or wiring
Available in four sizes 2-14 3 4 and 6 tubes
Download a brochure at wwwline-hidecom to find out more information
For more information on our CITY MULTI VRF product line visit our website at wwwmitsubishiprocom
_lIJrUlllln ~ ~IIII1 fInll l
~
l bull bull
JMITSUBISHI ELECTRIC 31
MSZ WALL-MOUNTED INDOOR UNITS (FOR MXZ-8 OUTDOOR UNITS)
R
(MSZ-GE12NA MODEL SHOWN)
-000 IIIIIII 9000 9000 12000 12000 14000 17200
Heating at 4r Rated Capacity Btuh 7200 10900 10900 14400 13600 18000 21600
F2 Power Supply I Phase Cycle Voltage J -phase 60Hz 208 230V 3
Iindoor Outdoor S1 S2 AC 208 230V
Iindoor Outdoor S2 S3 DC12-24V Voltage
Iindoor Remote vomr Iller Wireless Type (Optional Wired vomroller DC 12V)
IMCA A 10 IFan Motor FLA 076
DRY 162-226shy145-170shy
162-226shy205-272shy 230-275shy
Airflow at Cooling (CFM)
145-170-237-321-399 339-381
237 -321shy381-410
335-420shy 339-420shy(Quiet-Lo-Med-Hishy 399 533 533 Super Hi or Lo-Med-
WET 144-202shy109-134shy
144-202shy170-237shy 194-240shy
Fan Hi-Powerful)1 (CFM)
109-134-201-286-364 307-343
201-286shy350-367
300-385shy 304-385shy364 498 498
Airflow at Heating 145-170shy 145-170shy 145-170shy 205-247shy 230-275shy
(Quiet-Lo-Med-Hi- WET 233-321shy 237-321shy
166-240shy237-321shy
166-240shy304-367shy 339-431shy
Super Hi or Lo-Medshy (CFM) 406 406
367 -381 406
399-420 463 512
Hi-Powerful) 2 Sound Pressure Level at Cooling
19-22-30shy 26-32-38shy 28-33-38shy(Quiet-Lo-Med-Hi-Super Hi or Loshy dB(A) 19-22-30-37 -43 22-31-39-42
37-45 22-33-43-45
44-49 44-49Med-Hi-Powerful) 1
Sound Pressure Level at Heating 19-22-30shy 26-30-35shy 28-33-38shy
(Quiet-Lo-Med-Hi-Super Hi or Loshy dB(A) 19-22-30-37 -43 22-31-40-42 37-43
22-23-43-44 40-46 43-48
Med-Hi-Powerful) 2
I External Finish Color Munsell No 10Y 92 02
IWln 31 middot716
Dimension Unit 10 In 9 18 10-18 9middot18 10-18 9-18
IH In 11-58
I Weight Unit ILbs 22 27 22 27 22 I Field Drainpipe ~D lin 58 Remote Con-
Type Wireless Remote (Optional Wired Controller) troller
ITvpe B41QA Refrigerant ~s$ideOD lin 38 Pipe I Liquid Side 00 In 14
Connection IndoorOutdoor FlaredFlared
Method
1~
II 18000 22500
21600 27600
388-469shy 38$-469shy628-738 628-738
347-420shy 347-420shy562-661 562-661
388-469shy 388-469shy628-738 628-738
34-41-49-53 34-41-49-53
32-41-49-52 32-41-49-52
43-516
9-38
12-1316 37
58 38
MXZ-2B20NA is also compatible with the MSZ-A and MSZ-FD series indoor units NOTES Test conditions are based on AHRI 210240
1 Rating conditions (cooling)-Indoor DB 80deg F (27deg C) WB 67deg F (19deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(24deg C) 2 Rating conditions (heating)-Indoor DB 70deg F (21 deg C) WB 60deg F(16deg C) Outdoor DB 47deg F (8deg C) WB 43deg F(6deg C) 3 Indoor units receive power from outdoor units through field-supplied wiring
Specifications are subject to change without notice LIMITED WARRANTY Seven-year warranty on compressor Five-year warranty on parts For data on specific indoor unit combinations see page 21
SEZ DUCTED INDOOR UNIT (FOR MXZ-8 OUTDOOR UNITS)
I
Notes 1 Cooling-Indoor DS 80deg F(267deg C) WS 67deg F(194deg C) Outdoor DS 95deg F (35deg C) WS 75deg F(239deg C)
2 Heating-Indoor DS 70deg F(211 deg C) WS 60deg F(156deg C) Outdoor DS 47deg F (83deg C) WS 43deg F(61 deg C)
3 External static pressure is factory set to 006 WGAdjustable via the
1---------t---+-----L-------------1~---__I PAR-21MAA
1--_____----__________+-____---L____----~_____________1 4 Indoor units receive power
jE~~~~-------------r----1-----~-~~~~~~~~-----___1 from outdoor units through fieldsupplied interconnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven-year warranty on compressor Five-year
1---------------------+---+------------------------1 warranty on parts
~--__I_~----------+-------~l----------I For data on specific indoor unit combinations see page 21 - 23
I--~------+~-----------~----------r_------------I
- Reference page 17 for SEZ static performance curves
24 MITSUBISHI ELECTRIC
25-30-35-40 26-31-36-41 35-38-42-46
25-30-35-40 28-31-36-41 35-38-42-47
MFZ FLOORLOW WALL INDOOR UNIT (FOR middotMXZ-8 OUTDOOR UNITS)
------shy
-==
Airflow at Heating (CFM) 177-198-219-332 184-201-219-335 261-275-297-434
Voltage
Fan
Airflow at Cooling (Lo-Med-Hi-Super Hi)1
169-205-251-314 251-279-325-394
163-197-241-303 170-207-252-309 241-269-313-379
(Lo-Med-Hi-Super Hi) 2
SLZ CEILING-RECESSED INDOOR UNIT (FOR MXZ-8 OUTDOOR UNITS) EFFICIENCY RATINGS
Voltage
Fan
Galvanized-steel SheetsMunsell 64Y 89 04
Refrigerant Pipe
Model Indoor Unit Type SEER HSPF
MXZ-2B20NA-1
Non-dueted 18 89
Dueted and Non-dueted 1675 87
Dueted 155 85
MXZ-2B20NA-1 ENERGY STAR amp
TAX CREDIT 2 x MSZ-GE09NA 18 89
MXZ-3B24NA
lJon-dueted 175 93
Dueted and Non-dueted 1625 89
Dueted 150 85
MXZ-3B24NA ENERGY STAR amp
TAX CREDIT
2 x MSZ-GE06NA 1 x MSZ-GE09NA
175 93
MXZ-3B24NA ENERGY STAR amp
TAX CREDIT
2 x MSZ-GE06NA 1 x MSZ-GE12NA
175 93
MXZ-3B30NA
Non-dueted 175 105
Dueted and Non-dueted 16 100
Dueted 145 95
MXZ-4B36NA
Non-dueted 18 93
Dueted and Non-dueted 16 5 92
Dueted 150 9 0
MXZ-BB4BNA
Non-dueted 15 87
Dueted and Non-dueted 14B B8
Dueted 147 89
Connection IndoorOutdoor FlaredFlared
Method
Notes 1 Cooling-Indoor DB 80deg F(267deg C) WB 67deg F(194deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(239deg C) 2 Heating-Indoor DB 70deg F(21 1 deg C) WB 60deg F(156deg C) Outdoor DB 47deg F(83deg C) WB 43deg F(61 deg C) 3 Indoor units receive power from outdoor units through field supplied interconnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 25
Notes 1 Cooling-Indoor DB 80deg F(267deg C) WB 67deg F (194deg C) Outdoor DB 95deg F (35deg C)WB 75deg F (239deg C)
2 Heating-Indoor DB 70deg F(211deg C) WB 60deg F (156deg C) Outdoor DB 47 F (83deg C) WB 43deg F (61 deg C)
3 Indoor units receive power from outdoor units through field supplied interco(lnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven -year warranty on compressor Five-year warranty on parts
Presently there is no 1 1 system with the MFZ indoor unit
s c
N o J ro Vl
C ro n ~ n OJ t o J V)
M-SERIES RATING CONDITIONS
INDOOR INTAKE AIR TEMPERATURE
OUTDOOR INTAKE AIR TEMPERATURE
COOLING
MAXIMUM
95degF DB 71 degF WB (MU SUZ MXZ-2B20-13B243B304B36) 90degF DB 73degF WB (MUZY-GE MUZ-FE MUzy-D)
115degF DB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B24 3B304B368B48)
MINIMUM 67degF DB 57degF WB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B201 3B243B304B36)
14degF DB (MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B24 3B304B36) 23degF DB (MXZ-8B48) 6rF DB (MU)
MAXIMUM 80degF DB 6rF WB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B243B304B36)
75degF DB 65degF WB (MUZY-GE MUZY-GA24 MUZ-FE SUZ MXZ-2B20-1 3B243B304B36) 70degF DB (MXZ-8B48)
HEATING
MINIMUM 70degF DB 60degFWB (MUZ-GE MUZ-GA24 MUZ-D MUZ-FE SUZ MXZ-2B20-1 3B243B304B36)
-13degF DB -15degFWB (MUZ-FE) -4degF DB -5degF WB (SUZ MUZ-GE) 5degF DB 4degF WB (MUZ-GA24 MXZ-8B48NA) 6degF DB 5degF WB (MXZ-2B20-1 3B24 3B304B36) 14degF DB 13degFWB (MUZ-D)
MU units operate at intake air temperature down to 10deg Fwith the addition of an ICM-326HM-1 low temperature control
REFRIGERANT TUBING SETS
OPTIONAL ACCESSORIES
REFRIGERANT LINE LENGTH FLARE FLARE _INDOOR UNIT OUTDOOR UNIT
MS-A09WA MU-A09WA 35 MS-A12WA
65 MU-A12WA 35
MSY-GE09NA 65
MUY-GE09NA 40
MSY-GE12NA
65
MUY-GE12NA 65 40
MSY-GE15NA MUY-GE15NA 40
MSY-GE18NA
65
MUY-GE18NA 100 50
MSZ-GE09NA MUZ-GE09NA 65 40
MSZ-GE12NA MUZ-GE12NA 40
MSZ-GE15NA
65
MUZ-GE15NA 40
MSZ-GE18NA
65
MUZ-GE18NA 100 50
MSY-GE24NA MUY-GE24NA 100 50
MSZ-GE24NA MUZ-GE24NA 100 50
MSY-D30NA MUY-D30NA 100 50
MSZ-D30NA MUZ-D30NA 50
MSY-D36NA
100
MUY-D36NA 50
MSZ-D36NA
100
MUZ-D36NA 100 50
MSZ-FE09NA MUZ-FE09NA 40
MSZ-FE12NA
65
MUZ-FE12NA 40
MSZ-GE06091215NA MSZ-FE0912NA
65
MXZ-2B20NA-1 164 4933MFZ-KA0912NA SEZ-KD09 1215NA
MSZ-GE0609 121518NA MSZ-FE091218N MFZ-KA09 1218NA MXZ-3B24NA 164 4933 SEZ -KD09 12 15 18NA SLZ-KA09 12 15NA
MSZ-GE0609 121518NA MSZ-GA24NA MSZ-FE091218NA
MXZ-3B30NA 4933230MFZ-KA091218NA SEZ -KD09 121518NA SLZ-KA09 12 15NA
MSZ-GE0609121518NA MSZ-GE24NA MSZ-FE09 12 18NA
MXZ-4B36NA 230 4933MFZ-KA091218NA SEZ -KD09121518NA SLZ-KA09 12 15NA
MSZ-GE0609 12 15 18NA MSZ-GE24NA MSZ-FE09 12 18NA
MXZ-8B48NA 6698377MFZ-KA091218NA SEZ-KD09121518NA SLZ-KA09 12 15NA
PART NUMBER I USE WITH I DESCRIPTION
Port Adapters and Connection Pipes MAC-A454JP-E MXZ-Series Adapter 38 X12
MAC-A455JP-E MXZ-Series Adapter 12 X38
MAC-A456JP-E MXZ-Series Adapter 12 X58
MSDD-50AR-E MXZ-Series Branch Box Tee Distribution Pipe - Flare Connection between two branch boxes
MSDD-50BR-E MXZ-Series Branch Box Tee Distribution Pipe - Braze Connection between two branch boxes
PAC-493PI MXZ-Series Adapter 14 X38
PAC-SG76RJ-E MXZ-Series Adapter 38 X58
OPTIONAL ACCESSORIES CONTINUED ON NEXT PAGE
49 amp 66 applies to installations in which the outdoor unit is installed below indoor unit26 MITSUBISHI ELECTRIC
OPTIONAL ACCESSORIES (CONTINUED)
PART NUMBER USE WITH DESCRIPTION Control Options and Accessories
M21 JKO 307 M-Series Indoor Units Remote temperature sensor for M-Series indoor units
MAC-397IF-E
MAC-399IF-E
PAC-YU25HT
PAR-21 MM-G
M-Series INVERTER Units
M-Series INVERTER Units
SEZ-KD Indoor Units
Use with P-Series SEZ and for wired M-Series Controller
MA and contact terminal interface - Required to use PAR-21 MM wired wall mount controller with M-Series Systems
CMCN M-NET control adapter I Interface for Mr Slim M-Series MSYZ SEZ I MFZ
External Fan I Heater control relay adapter
Deluxe MA remote controller (Requires MAC-397IF-E for use with M-Series - MSYZ MFZ)
SEZ Wireless remote controller for SEZ units (Requires signal receiver PAR-SA9FA-E)PAR-FL32MA
PAR-SA9CA-E SEZ Wireless signal receiver for SEZ
3-pole disconnect switch 30A 600V turns off power between indoor and outdoor units shyM-SeriesTAZ-MS303
mounts in 2 X 4 utility box and requires standard single gang switch platecover - Low Ambient
ICM-326HM-2 M-Series Non-INVERTER units Low ambient head pressure controller MUZ-GE091215 IVIUZ-FE0912 SUZ-KD091215
Drain pan heaterMAC-640BH-U outdoor unit
MAC-641 BH-U MUZ-GE18 SUZ-KD18 outdoor unit Drain pan heater Filters
MAC-1415FT-E Anti-allergy enzyme filter
MAC-2300FT
MSZlMSY-D3036
Anti -allergy enzyme filter
MAC-308FT
MSYMSZ-GA24
MSZ-FD912 I FE0912 Platinum deodorizing filter
MAC-408FT-E Anti-allergy enzyme filter
MAC-415FT-E
M-Series Indoor Unit - GE09GE12GE15GE18
MFZ-KA Air Cleaning FilterAnti-Aliergy Enzyme Filter
MAC-418FT Anti-allergy enzyme filter
Filter Boxes
FBL1-1
MSZ- FD912 I FE091 2
FB Series Filter Box for SEZ-KD09NA Optional filter box with MERV 8 filters
FB Series Filter Box for SEZ-KD1215NAFBL1-2 Optional filter box with MERV 8 filters
and PEA-A 12M
FBL1-3 FB Series Filter Box for SEZ-KD18NA Optional filter box with MERV 8 filters
Pumps
SI1730-230 MSYZ - 30000 Btuh or greater Sauermann mini condensation pump 230V
S13100-115 MS-Series - non-INVERTER Sauermann mini condensation pump 115V
S13100-230 Sauermann mini condensation pump 230VMSYZ - Less than 30000 Btuh
Miscellaneous BRP-1 Bottom Return Plate for SEZ-KD09NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-2 Bottom Return Plate for SEZ-KD12KD15-NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-3 Bottom Return Plate for SEZ-KD18NA Converts low profile ducted indoor unit from rear return to bottom return
BV12FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderreglnsulated - 12
BV14FSI Use with any Mr Sl im multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 14
BV38FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 38
BV58FSI Use with any IVIr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 58
Condensing unit wall mounting brackets (set of 2) - 440 lb capacity painted steel NOTE CWMB1 IVIU and PU outdoor units Installer is responsible to select and provide suitable hardware and materials to insure proper
mount of bracket to wall
DSD-400N M-Series DiamondBacktrade Platform Stands MUZ-GE18 I MUZ(y)-03036 I
MAC-811DS Drain socket assemblySUZ-KA18
MAC-851DS MUZ-FD0912 Drain socket
MAC-855SG M-Series Air outlet guide
MAC-856SG M-Series Air outlet guide - MXZ-3B24 I 3B30 I 4B36 NA
MAC-860DS MUZ-GE091215 I MUZ-FE0912 Drain socket
MAC-889SG M-Series Air outlet guide- MXZ-2B20NA
MAC-S99SG M-Series Air outlet guide
PAC-SG59SG-E IVIXZ-SB4SNA Air outlet guide (1 piece) I MXZ-SB48NA (Requires 2 pieces)
PAC-SG61 DS-E MXZ-8B4SNA Drain socket - connector
PAC-SG64DP-E MXZ-SB48NA Drain pan
RCMKP1CB lVI-Series Wireless Lockdown bracket for remote controller
lILTRILlTE1 All M-Series Condensing unit mounting pad 16 x 36 x 3
MITSUBISHI ELECTRIC 27
MXZ-8 Series Port Adapter chart Port Adapter Unit Port
Combinations Required Size
MXZ-2B20NA-1
2-zone combinations wi NA
A 38 x both units s12K 14
1-MAC-A454JP-E B 38 x
6+15 14
9+15 1-MAC-A454JP-E
MXZ-3B24NA
All rated 2-zone combina-NA
A 12 x tions 14
All rated 3-zone combina-NA
B 38 x tions 14
C 38 x 14
MXZ-3B30NA
2-zone combinations wi at NA
A 12 x least one unit s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
9 + 24 14
3-zone combinations wi 1-MAC-A455JP-E
all units s12K
All other rated 3-zone NA
comb
MXZ-4B36NA
2-zone combinations wi at NA
A 12 x least one un it s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
6 + 24 14
1-MAC-A456JP-E D 38 x
9 + 24 14
3-zone combinations wi at NA
least two units s12K
3-zone combinations wi 1-MAC-A454JP-E
two units15K
6+6+24 or 6+9+24 1-MAC-A456JP-E
9+9+24 1-MAC-A456JP-E
4-zone combinations wi at 1-MAC-A455JP-E
least three units s12K
6+6+15+15 1-MAC-A454JP-E
6+6+15+15 1-MAC-A454JP-E
Note When using the Pu-A24BA PCA-A24KA or PEAD-A24AA two port adapter will be needed 1-MAC-A456JP-E (12 x 58) A port or 1-PACshySG76RJ-E (38 x 58) B C and D ports and 1-PAC493PI (14 x 38)
28 JMITSUBISHI ELECTRIC
6+6+246+9+24 6+12+249+9+24 9+12+24 or 12+12+24
6+15+24 6+18+24 9+15+249+18+24 12+15+24 or 12+18+24
15+15+24 15+18+24 or 18+18+24
15+24+24 or 18+24+24
Combinations of 4 or more zones
1-PAC-SG76RJ-E
See notes for application below
2
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
See notes for application below
PORT A =38 gas x 14 liquid
PORT B =38 gas x 14 liquid
PORT C =38 gas x 14 liquid
PORT A =38 gas x 14 liquid
PORT B = 38 gas x 14 liquid
PORT C = 38 gas x 14 liquid
PORT D =38 gas x 14 liquid
PORT E =12 gas x 14 liquid
Notes for application bull Check the lineset sizes for your indoor selected models bull Select the branch box or boxes needed for your application bull Compare indoor unit lineset sizes as compared to branch
box sizes bull Connect 15K + indoor units to the larger port on the
(PAC-AKA51 BC) bull Adapt lineset size with appropriate port adapter from
above list bull When using the PU-A24BA or PEAD-A24AA two port
adapter will be needed 1-MAC-A456JP-E (12 x 58) or 1-PAC-SG76RJ-E (38 x 58) and 1-PAC493PI (14 x 38)
-fv
~ DIAMONDBACKtrade
~) BV-Series Ball Valves Model numbers
BV14FFSI BV38FFSI
LISTED 891N REFRIGERANT
BV12FFSI VALVE bull Engineered for Mini-split andBV58FFSI
Multi-split HVAC Units bull Size available 14 38 12 58
bull Full Port Designbull Fully factory assembled bull Furnace brazed and pressure tested bull 700 PSIG Rated bull Each ball valve is equipped with Schraderreg Valve
for refrigerant service bull R-410A Compatible bull Design working pressure 700 PSIG bull Temperature range bull Flare Connections
-40 0 F to +3250 F (-400 C to + 1490
C) bull Forged brass body and seal cap bull Teflonreg seals and gaskets (no synthetic a-rings) bull Seal cap design permits valve operation without
removal of seal cap bull Suitable for use with R-11 R-22 R-123 R-125
R-134A R-236FA R-4202A R-402B R-404A R-407C R-410A R-500 R-502 and R-507
bull One year limited materials and workmanship
Part Number SAE Flare
A B C 0 E F
BV14FFSI 14 619 260 180 122 142 110
BV38FFSI 38 630 267 180 122 142 110
BV12FFSI 12 651 267 180 122 142 110
BV58FFSI 58 664 267 180 128 142 110
Ball valves come With an insulation piece warranty on Ball Valves
~ DIAMONDBACKtrade
~) Platform Stands
Lift the Mitsubishi Electric Comfort Solution
outdoor unit to new heights with our Diamondback Platform Stands
bull Easy to install
bull Available for all sizes of Mr Slim outdoor units
bull Color matched to the outdoor units
Model Number DSD-400N
L 15-34 x W 3-14 x H 3-14
r
)MITSUBISHI ELECTRIC 29
~ DIAMONDBACKtrade LINESETS
~~
Twin-Tube Lineset Insulation Design
bull Balanced outside diameter for uniform coiluncoil position stability
bull Minimum 12 insulation thickness on both tubes Diamondback Advantages include the following features
bull Quick efficient and economical field installation using factory applied Twin Tube insulation and flare connections with flare nuts mounted
bull Correct lengths for reducing waste and time
bull Quality consistency and economy
bull All Diamondback Lineset tubing is tested in accordance with ASTM E243
Filter Boxes
FB Series filter boxes are available in compatible sizes for all Mr Slim horizontal ducted indoor units
FBL 1 filter boxes include 1 thick pleated MERV 8 filter(s) installed Filters are tested in accordance with ANSIASHRAE Standard 522 and Rated Class 2 under UL Standard 900
The cabinet is constructed of non-insulated 20 gauge G-60 galvanized
FBL1-1 FB Series Filter Box for SEZ-KD09NA
FBL1-2 FB Series Filter Box for SEZ-KD12KD15-NA
FBL1-3 FB Series Filter Box for SEZ-KD18NA
steel with foam gasket and provides an air-tight connection to indoor unit and access door Gasket material complies with UL 723 requirements
A screw-through cabinet design for secure attachment to indoor unit and return connection in rear is easily field-converted to bottom return
30 MITSUBISHI ELECTRIC
bull
bull
bull
bull
bull
bull
LINE-HIDE~ Put a professional finish on air-conditioning
installations with an easy-to-install modular
system that beautifies exteriors and
protects Linesets drainlines and wiring
Can be use it indoors too Meets UL94v-O for interior applications
Has snap-on covers and a full selection of couplings elbows T-joints caps and more for any application complex or simple
Offers high-quality PVC with UV inhibitors for outdoor service in all weather conditions
Can be painted with most house paints to match exterior decors
Is not just for HVAC Hide any exterior cabling piping or wiring
Available in four sizes 2-14 3 4 and 6 tubes
Download a brochure at wwwline-hidecom to find out more information
For more information on our CITY MULTI VRF product line visit our website at wwwmitsubishiprocom
_lIJrUlllln ~ ~IIII1 fInll l
~
l bull bull
JMITSUBISHI ELECTRIC 31
25-30-35-40 26-31-36-41 35-38-42-46
25-30-35-40 28-31-36-41 35-38-42-47
MFZ FLOORLOW WALL INDOOR UNIT (FOR middotMXZ-8 OUTDOOR UNITS)
------shy
-==
Airflow at Heating (CFM) 177-198-219-332 184-201-219-335 261-275-297-434
Voltage
Fan
Airflow at Cooling (Lo-Med-Hi-Super Hi)1
169-205-251-314 251-279-325-394
163-197-241-303 170-207-252-309 241-269-313-379
(Lo-Med-Hi-Super Hi) 2
SLZ CEILING-RECESSED INDOOR UNIT (FOR MXZ-8 OUTDOOR UNITS) EFFICIENCY RATINGS
Voltage
Fan
Galvanized-steel SheetsMunsell 64Y 89 04
Refrigerant Pipe
Model Indoor Unit Type SEER HSPF
MXZ-2B20NA-1
Non-dueted 18 89
Dueted and Non-dueted 1675 87
Dueted 155 85
MXZ-2B20NA-1 ENERGY STAR amp
TAX CREDIT 2 x MSZ-GE09NA 18 89
MXZ-3B24NA
lJon-dueted 175 93
Dueted and Non-dueted 1625 89
Dueted 150 85
MXZ-3B24NA ENERGY STAR amp
TAX CREDIT
2 x MSZ-GE06NA 1 x MSZ-GE09NA
175 93
MXZ-3B24NA ENERGY STAR amp
TAX CREDIT
2 x MSZ-GE06NA 1 x MSZ-GE12NA
175 93
MXZ-3B30NA
Non-dueted 175 105
Dueted and Non-dueted 16 100
Dueted 145 95
MXZ-4B36NA
Non-dueted 18 93
Dueted and Non-dueted 16 5 92
Dueted 150 9 0
MXZ-BB4BNA
Non-dueted 15 87
Dueted and Non-dueted 14B B8
Dueted 147 89
Connection IndoorOutdoor FlaredFlared
Method
Notes 1 Cooling-Indoor DB 80deg F(267deg C) WB 67deg F(194deg C) Outdoor DB 95deg F(35deg C) WB 75deg F(239deg C) 2 Heating-Indoor DB 70deg F(21 1 deg C) WB 60deg F(156deg C) Outdoor DB 47deg F(83deg C) WB 43deg F(61 deg C) 3 Indoor units receive power from outdoor units through field supplied interconnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven-year warranty on compressor Five-year warranty on parts
MITSUBISHI ELECTRIC 25
Notes 1 Cooling-Indoor DB 80deg F(267deg C) WB 67deg F (194deg C) Outdoor DB 95deg F (35deg C)WB 75deg F (239deg C)
2 Heating-Indoor DB 70deg F(211deg C) WB 60deg F (156deg C) Outdoor DB 47 F (83deg C) WB 43deg F (61 deg C)
3 Indoor units receive power from outdoor units through field supplied interco(lnected wiring
Specifications are subject to change without notice
LIMITED WARRANTY Seven -year warranty on compressor Five-year warranty on parts
Presently there is no 1 1 system with the MFZ indoor unit
s c
N o J ro Vl
C ro n ~ n OJ t o J V)
M-SERIES RATING CONDITIONS
INDOOR INTAKE AIR TEMPERATURE
OUTDOOR INTAKE AIR TEMPERATURE
COOLING
MAXIMUM
95degF DB 71 degF WB (MU SUZ MXZ-2B20-13B243B304B36) 90degF DB 73degF WB (MUZY-GE MUZ-FE MUzy-D)
115degF DB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B24 3B304B368B48)
MINIMUM 67degF DB 57degF WB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B201 3B243B304B36)
14degF DB (MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B24 3B304B36) 23degF DB (MXZ-8B48) 6rF DB (MU)
MAXIMUM 80degF DB 6rF WB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B243B304B36)
75degF DB 65degF WB (MUZY-GE MUZY-GA24 MUZ-FE SUZ MXZ-2B20-1 3B243B304B36) 70degF DB (MXZ-8B48)
HEATING
MINIMUM 70degF DB 60degFWB (MUZ-GE MUZ-GA24 MUZ-D MUZ-FE SUZ MXZ-2B20-1 3B243B304B36)
-13degF DB -15degFWB (MUZ-FE) -4degF DB -5degF WB (SUZ MUZ-GE) 5degF DB 4degF WB (MUZ-GA24 MXZ-8B48NA) 6degF DB 5degF WB (MXZ-2B20-1 3B24 3B304B36) 14degF DB 13degFWB (MUZ-D)
MU units operate at intake air temperature down to 10deg Fwith the addition of an ICM-326HM-1 low temperature control
REFRIGERANT TUBING SETS
OPTIONAL ACCESSORIES
REFRIGERANT LINE LENGTH FLARE FLARE _INDOOR UNIT OUTDOOR UNIT
MS-A09WA MU-A09WA 35 MS-A12WA
65 MU-A12WA 35
MSY-GE09NA 65
MUY-GE09NA 40
MSY-GE12NA
65
MUY-GE12NA 65 40
MSY-GE15NA MUY-GE15NA 40
MSY-GE18NA
65
MUY-GE18NA 100 50
MSZ-GE09NA MUZ-GE09NA 65 40
MSZ-GE12NA MUZ-GE12NA 40
MSZ-GE15NA
65
MUZ-GE15NA 40
MSZ-GE18NA
65
MUZ-GE18NA 100 50
MSY-GE24NA MUY-GE24NA 100 50
MSZ-GE24NA MUZ-GE24NA 100 50
MSY-D30NA MUY-D30NA 100 50
MSZ-D30NA MUZ-D30NA 50
MSY-D36NA
100
MUY-D36NA 50
MSZ-D36NA
100
MUZ-D36NA 100 50
MSZ-FE09NA MUZ-FE09NA 40
MSZ-FE12NA
65
MUZ-FE12NA 40
MSZ-GE06091215NA MSZ-FE0912NA
65
MXZ-2B20NA-1 164 4933MFZ-KA0912NA SEZ-KD09 1215NA
MSZ-GE0609 121518NA MSZ-FE091218N MFZ-KA09 1218NA MXZ-3B24NA 164 4933 SEZ -KD09 12 15 18NA SLZ-KA09 12 15NA
MSZ-GE0609 121518NA MSZ-GA24NA MSZ-FE091218NA
MXZ-3B30NA 4933230MFZ-KA091218NA SEZ -KD09 121518NA SLZ-KA09 12 15NA
MSZ-GE0609121518NA MSZ-GE24NA MSZ-FE09 12 18NA
MXZ-4B36NA 230 4933MFZ-KA091218NA SEZ -KD09121518NA SLZ-KA09 12 15NA
MSZ-GE0609 12 15 18NA MSZ-GE24NA MSZ-FE09 12 18NA
MXZ-8B48NA 6698377MFZ-KA091218NA SEZ-KD09121518NA SLZ-KA09 12 15NA
PART NUMBER I USE WITH I DESCRIPTION
Port Adapters and Connection Pipes MAC-A454JP-E MXZ-Series Adapter 38 X12
MAC-A455JP-E MXZ-Series Adapter 12 X38
MAC-A456JP-E MXZ-Series Adapter 12 X58
MSDD-50AR-E MXZ-Series Branch Box Tee Distribution Pipe - Flare Connection between two branch boxes
MSDD-50BR-E MXZ-Series Branch Box Tee Distribution Pipe - Braze Connection between two branch boxes
PAC-493PI MXZ-Series Adapter 14 X38
PAC-SG76RJ-E MXZ-Series Adapter 38 X58
OPTIONAL ACCESSORIES CONTINUED ON NEXT PAGE
49 amp 66 applies to installations in which the outdoor unit is installed below indoor unit26 MITSUBISHI ELECTRIC
OPTIONAL ACCESSORIES (CONTINUED)
PART NUMBER USE WITH DESCRIPTION Control Options and Accessories
M21 JKO 307 M-Series Indoor Units Remote temperature sensor for M-Series indoor units
MAC-397IF-E
MAC-399IF-E
PAC-YU25HT
PAR-21 MM-G
M-Series INVERTER Units
M-Series INVERTER Units
SEZ-KD Indoor Units
Use with P-Series SEZ and for wired M-Series Controller
MA and contact terminal interface - Required to use PAR-21 MM wired wall mount controller with M-Series Systems
CMCN M-NET control adapter I Interface for Mr Slim M-Series MSYZ SEZ I MFZ
External Fan I Heater control relay adapter
Deluxe MA remote controller (Requires MAC-397IF-E for use with M-Series - MSYZ MFZ)
SEZ Wireless remote controller for SEZ units (Requires signal receiver PAR-SA9FA-E)PAR-FL32MA
PAR-SA9CA-E SEZ Wireless signal receiver for SEZ
3-pole disconnect switch 30A 600V turns off power between indoor and outdoor units shyM-SeriesTAZ-MS303
mounts in 2 X 4 utility box and requires standard single gang switch platecover - Low Ambient
ICM-326HM-2 M-Series Non-INVERTER units Low ambient head pressure controller MUZ-GE091215 IVIUZ-FE0912 SUZ-KD091215
Drain pan heaterMAC-640BH-U outdoor unit
MAC-641 BH-U MUZ-GE18 SUZ-KD18 outdoor unit Drain pan heater Filters
MAC-1415FT-E Anti-allergy enzyme filter
MAC-2300FT
MSZlMSY-D3036
Anti -allergy enzyme filter
MAC-308FT
MSYMSZ-GA24
MSZ-FD912 I FE0912 Platinum deodorizing filter
MAC-408FT-E Anti-allergy enzyme filter
MAC-415FT-E
M-Series Indoor Unit - GE09GE12GE15GE18
MFZ-KA Air Cleaning FilterAnti-Aliergy Enzyme Filter
MAC-418FT Anti-allergy enzyme filter
Filter Boxes
FBL1-1
MSZ- FD912 I FE091 2
FB Series Filter Box for SEZ-KD09NA Optional filter box with MERV 8 filters
FB Series Filter Box for SEZ-KD1215NAFBL1-2 Optional filter box with MERV 8 filters
and PEA-A 12M
FBL1-3 FB Series Filter Box for SEZ-KD18NA Optional filter box with MERV 8 filters
Pumps
SI1730-230 MSYZ - 30000 Btuh or greater Sauermann mini condensation pump 230V
S13100-115 MS-Series - non-INVERTER Sauermann mini condensation pump 115V
S13100-230 Sauermann mini condensation pump 230VMSYZ - Less than 30000 Btuh
Miscellaneous BRP-1 Bottom Return Plate for SEZ-KD09NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-2 Bottom Return Plate for SEZ-KD12KD15-NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-3 Bottom Return Plate for SEZ-KD18NA Converts low profile ducted indoor unit from rear return to bottom return
BV12FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderreglnsulated - 12
BV14FSI Use with any Mr Sl im multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 14
BV38FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 38
BV58FSI Use with any IVIr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 58
Condensing unit wall mounting brackets (set of 2) - 440 lb capacity painted steel NOTE CWMB1 IVIU and PU outdoor units Installer is responsible to select and provide suitable hardware and materials to insure proper
mount of bracket to wall
DSD-400N M-Series DiamondBacktrade Platform Stands MUZ-GE18 I MUZ(y)-03036 I
MAC-811DS Drain socket assemblySUZ-KA18
MAC-851DS MUZ-FD0912 Drain socket
MAC-855SG M-Series Air outlet guide
MAC-856SG M-Series Air outlet guide - MXZ-3B24 I 3B30 I 4B36 NA
MAC-860DS MUZ-GE091215 I MUZ-FE0912 Drain socket
MAC-889SG M-Series Air outlet guide- MXZ-2B20NA
MAC-S99SG M-Series Air outlet guide
PAC-SG59SG-E IVIXZ-SB4SNA Air outlet guide (1 piece) I MXZ-SB48NA (Requires 2 pieces)
PAC-SG61 DS-E MXZ-8B4SNA Drain socket - connector
PAC-SG64DP-E MXZ-SB48NA Drain pan
RCMKP1CB lVI-Series Wireless Lockdown bracket for remote controller
lILTRILlTE1 All M-Series Condensing unit mounting pad 16 x 36 x 3
MITSUBISHI ELECTRIC 27
MXZ-8 Series Port Adapter chart Port Adapter Unit Port
Combinations Required Size
MXZ-2B20NA-1
2-zone combinations wi NA
A 38 x both units s12K 14
1-MAC-A454JP-E B 38 x
6+15 14
9+15 1-MAC-A454JP-E
MXZ-3B24NA
All rated 2-zone combina-NA
A 12 x tions 14
All rated 3-zone combina-NA
B 38 x tions 14
C 38 x 14
MXZ-3B30NA
2-zone combinations wi at NA
A 12 x least one unit s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
9 + 24 14
3-zone combinations wi 1-MAC-A455JP-E
all units s12K
All other rated 3-zone NA
comb
MXZ-4B36NA
2-zone combinations wi at NA
A 12 x least one un it s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
6 + 24 14
1-MAC-A456JP-E D 38 x
9 + 24 14
3-zone combinations wi at NA
least two units s12K
3-zone combinations wi 1-MAC-A454JP-E
two units15K
6+6+24 or 6+9+24 1-MAC-A456JP-E
9+9+24 1-MAC-A456JP-E
4-zone combinations wi at 1-MAC-A455JP-E
least three units s12K
6+6+15+15 1-MAC-A454JP-E
6+6+15+15 1-MAC-A454JP-E
Note When using the Pu-A24BA PCA-A24KA or PEAD-A24AA two port adapter will be needed 1-MAC-A456JP-E (12 x 58) A port or 1-PACshySG76RJ-E (38 x 58) B C and D ports and 1-PAC493PI (14 x 38)
28 JMITSUBISHI ELECTRIC
6+6+246+9+24 6+12+249+9+24 9+12+24 or 12+12+24
6+15+24 6+18+24 9+15+249+18+24 12+15+24 or 12+18+24
15+15+24 15+18+24 or 18+18+24
15+24+24 or 18+24+24
Combinations of 4 or more zones
1-PAC-SG76RJ-E
See notes for application below
2
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
See notes for application below
PORT A =38 gas x 14 liquid
PORT B =38 gas x 14 liquid
PORT C =38 gas x 14 liquid
PORT A =38 gas x 14 liquid
PORT B = 38 gas x 14 liquid
PORT C = 38 gas x 14 liquid
PORT D =38 gas x 14 liquid
PORT E =12 gas x 14 liquid
Notes for application bull Check the lineset sizes for your indoor selected models bull Select the branch box or boxes needed for your application bull Compare indoor unit lineset sizes as compared to branch
box sizes bull Connect 15K + indoor units to the larger port on the
(PAC-AKA51 BC) bull Adapt lineset size with appropriate port adapter from
above list bull When using the PU-A24BA or PEAD-A24AA two port
adapter will be needed 1-MAC-A456JP-E (12 x 58) or 1-PAC-SG76RJ-E (38 x 58) and 1-PAC493PI (14 x 38)
-fv
~ DIAMONDBACKtrade
~) BV-Series Ball Valves Model numbers
BV14FFSI BV38FFSI
LISTED 891N REFRIGERANT
BV12FFSI VALVE bull Engineered for Mini-split andBV58FFSI
Multi-split HVAC Units bull Size available 14 38 12 58
bull Full Port Designbull Fully factory assembled bull Furnace brazed and pressure tested bull 700 PSIG Rated bull Each ball valve is equipped with Schraderreg Valve
for refrigerant service bull R-410A Compatible bull Design working pressure 700 PSIG bull Temperature range bull Flare Connections
-40 0 F to +3250 F (-400 C to + 1490
C) bull Forged brass body and seal cap bull Teflonreg seals and gaskets (no synthetic a-rings) bull Seal cap design permits valve operation without
removal of seal cap bull Suitable for use with R-11 R-22 R-123 R-125
R-134A R-236FA R-4202A R-402B R-404A R-407C R-410A R-500 R-502 and R-507
bull One year limited materials and workmanship
Part Number SAE Flare
A B C 0 E F
BV14FFSI 14 619 260 180 122 142 110
BV38FFSI 38 630 267 180 122 142 110
BV12FFSI 12 651 267 180 122 142 110
BV58FFSI 58 664 267 180 128 142 110
Ball valves come With an insulation piece warranty on Ball Valves
~ DIAMONDBACKtrade
~) Platform Stands
Lift the Mitsubishi Electric Comfort Solution
outdoor unit to new heights with our Diamondback Platform Stands
bull Easy to install
bull Available for all sizes of Mr Slim outdoor units
bull Color matched to the outdoor units
Model Number DSD-400N
L 15-34 x W 3-14 x H 3-14
r
)MITSUBISHI ELECTRIC 29
~ DIAMONDBACKtrade LINESETS
~~
Twin-Tube Lineset Insulation Design
bull Balanced outside diameter for uniform coiluncoil position stability
bull Minimum 12 insulation thickness on both tubes Diamondback Advantages include the following features
bull Quick efficient and economical field installation using factory applied Twin Tube insulation and flare connections with flare nuts mounted
bull Correct lengths for reducing waste and time
bull Quality consistency and economy
bull All Diamondback Lineset tubing is tested in accordance with ASTM E243
Filter Boxes
FB Series filter boxes are available in compatible sizes for all Mr Slim horizontal ducted indoor units
FBL 1 filter boxes include 1 thick pleated MERV 8 filter(s) installed Filters are tested in accordance with ANSIASHRAE Standard 522 and Rated Class 2 under UL Standard 900
The cabinet is constructed of non-insulated 20 gauge G-60 galvanized
FBL1-1 FB Series Filter Box for SEZ-KD09NA
FBL1-2 FB Series Filter Box for SEZ-KD12KD15-NA
FBL1-3 FB Series Filter Box for SEZ-KD18NA
steel with foam gasket and provides an air-tight connection to indoor unit and access door Gasket material complies with UL 723 requirements
A screw-through cabinet design for secure attachment to indoor unit and return connection in rear is easily field-converted to bottom return
30 MITSUBISHI ELECTRIC
bull
bull
bull
bull
bull
bull
LINE-HIDE~ Put a professional finish on air-conditioning
installations with an easy-to-install modular
system that beautifies exteriors and
protects Linesets drainlines and wiring
Can be use it indoors too Meets UL94v-O for interior applications
Has snap-on covers and a full selection of couplings elbows T-joints caps and more for any application complex or simple
Offers high-quality PVC with UV inhibitors for outdoor service in all weather conditions
Can be painted with most house paints to match exterior decors
Is not just for HVAC Hide any exterior cabling piping or wiring
Available in four sizes 2-14 3 4 and 6 tubes
Download a brochure at wwwline-hidecom to find out more information
For more information on our CITY MULTI VRF product line visit our website at wwwmitsubishiprocom
_lIJrUlllln ~ ~IIII1 fInll l
~
l bull bull
JMITSUBISHI ELECTRIC 31
M-SERIES RATING CONDITIONS
INDOOR INTAKE AIR TEMPERATURE
OUTDOOR INTAKE AIR TEMPERATURE
COOLING
MAXIMUM
95degF DB 71 degF WB (MU SUZ MXZ-2B20-13B243B304B36) 90degF DB 73degF WB (MUZY-GE MUZ-FE MUzy-D)
115degF DB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B24 3B304B368B48)
MINIMUM 67degF DB 57degF WB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B201 3B243B304B36)
14degF DB (MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B24 3B304B36) 23degF DB (MXZ-8B48) 6rF DB (MU)
MAXIMUM 80degF DB 6rF WB (MU MUZY-GE MUzy-D MUZ-FE SUZ MXZ-2B20-1 3B243B304B36)
75degF DB 65degF WB (MUZY-GE MUZY-GA24 MUZ-FE SUZ MXZ-2B20-1 3B243B304B36) 70degF DB (MXZ-8B48)
HEATING
MINIMUM 70degF DB 60degFWB (MUZ-GE MUZ-GA24 MUZ-D MUZ-FE SUZ MXZ-2B20-1 3B243B304B36)
-13degF DB -15degFWB (MUZ-FE) -4degF DB -5degF WB (SUZ MUZ-GE) 5degF DB 4degF WB (MUZ-GA24 MXZ-8B48NA) 6degF DB 5degF WB (MXZ-2B20-1 3B24 3B304B36) 14degF DB 13degFWB (MUZ-D)
MU units operate at intake air temperature down to 10deg Fwith the addition of an ICM-326HM-1 low temperature control
REFRIGERANT TUBING SETS
OPTIONAL ACCESSORIES
REFRIGERANT LINE LENGTH FLARE FLARE _INDOOR UNIT OUTDOOR UNIT
MS-A09WA MU-A09WA 35 MS-A12WA
65 MU-A12WA 35
MSY-GE09NA 65
MUY-GE09NA 40
MSY-GE12NA
65
MUY-GE12NA 65 40
MSY-GE15NA MUY-GE15NA 40
MSY-GE18NA
65
MUY-GE18NA 100 50
MSZ-GE09NA MUZ-GE09NA 65 40
MSZ-GE12NA MUZ-GE12NA 40
MSZ-GE15NA
65
MUZ-GE15NA 40
MSZ-GE18NA
65
MUZ-GE18NA 100 50
MSY-GE24NA MUY-GE24NA 100 50
MSZ-GE24NA MUZ-GE24NA 100 50
MSY-D30NA MUY-D30NA 100 50
MSZ-D30NA MUZ-D30NA 50
MSY-D36NA
100
MUY-D36NA 50
MSZ-D36NA
100
MUZ-D36NA 100 50
MSZ-FE09NA MUZ-FE09NA 40
MSZ-FE12NA
65
MUZ-FE12NA 40
MSZ-GE06091215NA MSZ-FE0912NA
65
MXZ-2B20NA-1 164 4933MFZ-KA0912NA SEZ-KD09 1215NA
MSZ-GE0609 121518NA MSZ-FE091218N MFZ-KA09 1218NA MXZ-3B24NA 164 4933 SEZ -KD09 12 15 18NA SLZ-KA09 12 15NA
MSZ-GE0609 121518NA MSZ-GA24NA MSZ-FE091218NA
MXZ-3B30NA 4933230MFZ-KA091218NA SEZ -KD09 121518NA SLZ-KA09 12 15NA
MSZ-GE0609121518NA MSZ-GE24NA MSZ-FE09 12 18NA
MXZ-4B36NA 230 4933MFZ-KA091218NA SEZ -KD09121518NA SLZ-KA09 12 15NA
MSZ-GE0609 12 15 18NA MSZ-GE24NA MSZ-FE09 12 18NA
MXZ-8B48NA 6698377MFZ-KA091218NA SEZ-KD09121518NA SLZ-KA09 12 15NA
PART NUMBER I USE WITH I DESCRIPTION
Port Adapters and Connection Pipes MAC-A454JP-E MXZ-Series Adapter 38 X12
MAC-A455JP-E MXZ-Series Adapter 12 X38
MAC-A456JP-E MXZ-Series Adapter 12 X58
MSDD-50AR-E MXZ-Series Branch Box Tee Distribution Pipe - Flare Connection between two branch boxes
MSDD-50BR-E MXZ-Series Branch Box Tee Distribution Pipe - Braze Connection between two branch boxes
PAC-493PI MXZ-Series Adapter 14 X38
PAC-SG76RJ-E MXZ-Series Adapter 38 X58
OPTIONAL ACCESSORIES CONTINUED ON NEXT PAGE
49 amp 66 applies to installations in which the outdoor unit is installed below indoor unit26 MITSUBISHI ELECTRIC
OPTIONAL ACCESSORIES (CONTINUED)
PART NUMBER USE WITH DESCRIPTION Control Options and Accessories
M21 JKO 307 M-Series Indoor Units Remote temperature sensor for M-Series indoor units
MAC-397IF-E
MAC-399IF-E
PAC-YU25HT
PAR-21 MM-G
M-Series INVERTER Units
M-Series INVERTER Units
SEZ-KD Indoor Units
Use with P-Series SEZ and for wired M-Series Controller
MA and contact terminal interface - Required to use PAR-21 MM wired wall mount controller with M-Series Systems
CMCN M-NET control adapter I Interface for Mr Slim M-Series MSYZ SEZ I MFZ
External Fan I Heater control relay adapter
Deluxe MA remote controller (Requires MAC-397IF-E for use with M-Series - MSYZ MFZ)
SEZ Wireless remote controller for SEZ units (Requires signal receiver PAR-SA9FA-E)PAR-FL32MA
PAR-SA9CA-E SEZ Wireless signal receiver for SEZ
3-pole disconnect switch 30A 600V turns off power between indoor and outdoor units shyM-SeriesTAZ-MS303
mounts in 2 X 4 utility box and requires standard single gang switch platecover - Low Ambient
ICM-326HM-2 M-Series Non-INVERTER units Low ambient head pressure controller MUZ-GE091215 IVIUZ-FE0912 SUZ-KD091215
Drain pan heaterMAC-640BH-U outdoor unit
MAC-641 BH-U MUZ-GE18 SUZ-KD18 outdoor unit Drain pan heater Filters
MAC-1415FT-E Anti-allergy enzyme filter
MAC-2300FT
MSZlMSY-D3036
Anti -allergy enzyme filter
MAC-308FT
MSYMSZ-GA24
MSZ-FD912 I FE0912 Platinum deodorizing filter
MAC-408FT-E Anti-allergy enzyme filter
MAC-415FT-E
M-Series Indoor Unit - GE09GE12GE15GE18
MFZ-KA Air Cleaning FilterAnti-Aliergy Enzyme Filter
MAC-418FT Anti-allergy enzyme filter
Filter Boxes
FBL1-1
MSZ- FD912 I FE091 2
FB Series Filter Box for SEZ-KD09NA Optional filter box with MERV 8 filters
FB Series Filter Box for SEZ-KD1215NAFBL1-2 Optional filter box with MERV 8 filters
and PEA-A 12M
FBL1-3 FB Series Filter Box for SEZ-KD18NA Optional filter box with MERV 8 filters
Pumps
SI1730-230 MSYZ - 30000 Btuh or greater Sauermann mini condensation pump 230V
S13100-115 MS-Series - non-INVERTER Sauermann mini condensation pump 115V
S13100-230 Sauermann mini condensation pump 230VMSYZ - Less than 30000 Btuh
Miscellaneous BRP-1 Bottom Return Plate for SEZ-KD09NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-2 Bottom Return Plate for SEZ-KD12KD15-NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-3 Bottom Return Plate for SEZ-KD18NA Converts low profile ducted indoor unit from rear return to bottom return
BV12FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderreglnsulated - 12
BV14FSI Use with any Mr Sl im multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 14
BV38FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 38
BV58FSI Use with any IVIr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 58
Condensing unit wall mounting brackets (set of 2) - 440 lb capacity painted steel NOTE CWMB1 IVIU and PU outdoor units Installer is responsible to select and provide suitable hardware and materials to insure proper
mount of bracket to wall
DSD-400N M-Series DiamondBacktrade Platform Stands MUZ-GE18 I MUZ(y)-03036 I
MAC-811DS Drain socket assemblySUZ-KA18
MAC-851DS MUZ-FD0912 Drain socket
MAC-855SG M-Series Air outlet guide
MAC-856SG M-Series Air outlet guide - MXZ-3B24 I 3B30 I 4B36 NA
MAC-860DS MUZ-GE091215 I MUZ-FE0912 Drain socket
MAC-889SG M-Series Air outlet guide- MXZ-2B20NA
MAC-S99SG M-Series Air outlet guide
PAC-SG59SG-E IVIXZ-SB4SNA Air outlet guide (1 piece) I MXZ-SB48NA (Requires 2 pieces)
PAC-SG61 DS-E MXZ-8B4SNA Drain socket - connector
PAC-SG64DP-E MXZ-SB48NA Drain pan
RCMKP1CB lVI-Series Wireless Lockdown bracket for remote controller
lILTRILlTE1 All M-Series Condensing unit mounting pad 16 x 36 x 3
MITSUBISHI ELECTRIC 27
MXZ-8 Series Port Adapter chart Port Adapter Unit Port
Combinations Required Size
MXZ-2B20NA-1
2-zone combinations wi NA
A 38 x both units s12K 14
1-MAC-A454JP-E B 38 x
6+15 14
9+15 1-MAC-A454JP-E
MXZ-3B24NA
All rated 2-zone combina-NA
A 12 x tions 14
All rated 3-zone combina-NA
B 38 x tions 14
C 38 x 14
MXZ-3B30NA
2-zone combinations wi at NA
A 12 x least one unit s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
9 + 24 14
3-zone combinations wi 1-MAC-A455JP-E
all units s12K
All other rated 3-zone NA
comb
MXZ-4B36NA
2-zone combinations wi at NA
A 12 x least one un it s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
6 + 24 14
1-MAC-A456JP-E D 38 x
9 + 24 14
3-zone combinations wi at NA
least two units s12K
3-zone combinations wi 1-MAC-A454JP-E
two units15K
6+6+24 or 6+9+24 1-MAC-A456JP-E
9+9+24 1-MAC-A456JP-E
4-zone combinations wi at 1-MAC-A455JP-E
least three units s12K
6+6+15+15 1-MAC-A454JP-E
6+6+15+15 1-MAC-A454JP-E
Note When using the Pu-A24BA PCA-A24KA or PEAD-A24AA two port adapter will be needed 1-MAC-A456JP-E (12 x 58) A port or 1-PACshySG76RJ-E (38 x 58) B C and D ports and 1-PAC493PI (14 x 38)
28 JMITSUBISHI ELECTRIC
6+6+246+9+24 6+12+249+9+24 9+12+24 or 12+12+24
6+15+24 6+18+24 9+15+249+18+24 12+15+24 or 12+18+24
15+15+24 15+18+24 or 18+18+24
15+24+24 or 18+24+24
Combinations of 4 or more zones
1-PAC-SG76RJ-E
See notes for application below
2
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
See notes for application below
PORT A =38 gas x 14 liquid
PORT B =38 gas x 14 liquid
PORT C =38 gas x 14 liquid
PORT A =38 gas x 14 liquid
PORT B = 38 gas x 14 liquid
PORT C = 38 gas x 14 liquid
PORT D =38 gas x 14 liquid
PORT E =12 gas x 14 liquid
Notes for application bull Check the lineset sizes for your indoor selected models bull Select the branch box or boxes needed for your application bull Compare indoor unit lineset sizes as compared to branch
box sizes bull Connect 15K + indoor units to the larger port on the
(PAC-AKA51 BC) bull Adapt lineset size with appropriate port adapter from
above list bull When using the PU-A24BA or PEAD-A24AA two port
adapter will be needed 1-MAC-A456JP-E (12 x 58) or 1-PAC-SG76RJ-E (38 x 58) and 1-PAC493PI (14 x 38)
-fv
~ DIAMONDBACKtrade
~) BV-Series Ball Valves Model numbers
BV14FFSI BV38FFSI
LISTED 891N REFRIGERANT
BV12FFSI VALVE bull Engineered for Mini-split andBV58FFSI
Multi-split HVAC Units bull Size available 14 38 12 58
bull Full Port Designbull Fully factory assembled bull Furnace brazed and pressure tested bull 700 PSIG Rated bull Each ball valve is equipped with Schraderreg Valve
for refrigerant service bull R-410A Compatible bull Design working pressure 700 PSIG bull Temperature range bull Flare Connections
-40 0 F to +3250 F (-400 C to + 1490
C) bull Forged brass body and seal cap bull Teflonreg seals and gaskets (no synthetic a-rings) bull Seal cap design permits valve operation without
removal of seal cap bull Suitable for use with R-11 R-22 R-123 R-125
R-134A R-236FA R-4202A R-402B R-404A R-407C R-410A R-500 R-502 and R-507
bull One year limited materials and workmanship
Part Number SAE Flare
A B C 0 E F
BV14FFSI 14 619 260 180 122 142 110
BV38FFSI 38 630 267 180 122 142 110
BV12FFSI 12 651 267 180 122 142 110
BV58FFSI 58 664 267 180 128 142 110
Ball valves come With an insulation piece warranty on Ball Valves
~ DIAMONDBACKtrade
~) Platform Stands
Lift the Mitsubishi Electric Comfort Solution
outdoor unit to new heights with our Diamondback Platform Stands
bull Easy to install
bull Available for all sizes of Mr Slim outdoor units
bull Color matched to the outdoor units
Model Number DSD-400N
L 15-34 x W 3-14 x H 3-14
r
)MITSUBISHI ELECTRIC 29
~ DIAMONDBACKtrade LINESETS
~~
Twin-Tube Lineset Insulation Design
bull Balanced outside diameter for uniform coiluncoil position stability
bull Minimum 12 insulation thickness on both tubes Diamondback Advantages include the following features
bull Quick efficient and economical field installation using factory applied Twin Tube insulation and flare connections with flare nuts mounted
bull Correct lengths for reducing waste and time
bull Quality consistency and economy
bull All Diamondback Lineset tubing is tested in accordance with ASTM E243
Filter Boxes
FB Series filter boxes are available in compatible sizes for all Mr Slim horizontal ducted indoor units
FBL 1 filter boxes include 1 thick pleated MERV 8 filter(s) installed Filters are tested in accordance with ANSIASHRAE Standard 522 and Rated Class 2 under UL Standard 900
The cabinet is constructed of non-insulated 20 gauge G-60 galvanized
FBL1-1 FB Series Filter Box for SEZ-KD09NA
FBL1-2 FB Series Filter Box for SEZ-KD12KD15-NA
FBL1-3 FB Series Filter Box for SEZ-KD18NA
steel with foam gasket and provides an air-tight connection to indoor unit and access door Gasket material complies with UL 723 requirements
A screw-through cabinet design for secure attachment to indoor unit and return connection in rear is easily field-converted to bottom return
30 MITSUBISHI ELECTRIC
bull
bull
bull
bull
bull
bull
LINE-HIDE~ Put a professional finish on air-conditioning
installations with an easy-to-install modular
system that beautifies exteriors and
protects Linesets drainlines and wiring
Can be use it indoors too Meets UL94v-O for interior applications
Has snap-on covers and a full selection of couplings elbows T-joints caps and more for any application complex or simple
Offers high-quality PVC with UV inhibitors for outdoor service in all weather conditions
Can be painted with most house paints to match exterior decors
Is not just for HVAC Hide any exterior cabling piping or wiring
Available in four sizes 2-14 3 4 and 6 tubes
Download a brochure at wwwline-hidecom to find out more information
For more information on our CITY MULTI VRF product line visit our website at wwwmitsubishiprocom
_lIJrUlllln ~ ~IIII1 fInll l
~
l bull bull
JMITSUBISHI ELECTRIC 31
OPTIONAL ACCESSORIES (CONTINUED)
PART NUMBER USE WITH DESCRIPTION Control Options and Accessories
M21 JKO 307 M-Series Indoor Units Remote temperature sensor for M-Series indoor units
MAC-397IF-E
MAC-399IF-E
PAC-YU25HT
PAR-21 MM-G
M-Series INVERTER Units
M-Series INVERTER Units
SEZ-KD Indoor Units
Use with P-Series SEZ and for wired M-Series Controller
MA and contact terminal interface - Required to use PAR-21 MM wired wall mount controller with M-Series Systems
CMCN M-NET control adapter I Interface for Mr Slim M-Series MSYZ SEZ I MFZ
External Fan I Heater control relay adapter
Deluxe MA remote controller (Requires MAC-397IF-E for use with M-Series - MSYZ MFZ)
SEZ Wireless remote controller for SEZ units (Requires signal receiver PAR-SA9FA-E)PAR-FL32MA
PAR-SA9CA-E SEZ Wireless signal receiver for SEZ
3-pole disconnect switch 30A 600V turns off power between indoor and outdoor units shyM-SeriesTAZ-MS303
mounts in 2 X 4 utility box and requires standard single gang switch platecover - Low Ambient
ICM-326HM-2 M-Series Non-INVERTER units Low ambient head pressure controller MUZ-GE091215 IVIUZ-FE0912 SUZ-KD091215
Drain pan heaterMAC-640BH-U outdoor unit
MAC-641 BH-U MUZ-GE18 SUZ-KD18 outdoor unit Drain pan heater Filters
MAC-1415FT-E Anti-allergy enzyme filter
MAC-2300FT
MSZlMSY-D3036
Anti -allergy enzyme filter
MAC-308FT
MSYMSZ-GA24
MSZ-FD912 I FE0912 Platinum deodorizing filter
MAC-408FT-E Anti-allergy enzyme filter
MAC-415FT-E
M-Series Indoor Unit - GE09GE12GE15GE18
MFZ-KA Air Cleaning FilterAnti-Aliergy Enzyme Filter
MAC-418FT Anti-allergy enzyme filter
Filter Boxes
FBL1-1
MSZ- FD912 I FE091 2
FB Series Filter Box for SEZ-KD09NA Optional filter box with MERV 8 filters
FB Series Filter Box for SEZ-KD1215NAFBL1-2 Optional filter box with MERV 8 filters
and PEA-A 12M
FBL1-3 FB Series Filter Box for SEZ-KD18NA Optional filter box with MERV 8 filters
Pumps
SI1730-230 MSYZ - 30000 Btuh or greater Sauermann mini condensation pump 230V
S13100-115 MS-Series - non-INVERTER Sauermann mini condensation pump 115V
S13100-230 Sauermann mini condensation pump 230VMSYZ - Less than 30000 Btuh
Miscellaneous BRP-1 Bottom Return Plate for SEZ-KD09NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-2 Bottom Return Plate for SEZ-KD12KD15-NA Converts low profile ducted indoor unit from rear return to bottom return
BRP-3 Bottom Return Plate for SEZ-KD18NA Converts low profile ducted indoor unit from rear return to bottom return
BV12FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderreglnsulated - 12
BV14FSI Use with any Mr Sl im multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 14
BV38FSI Use with any Mr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 38
BV58FSI Use with any IVIr Slim multi-zone product Refrigeration Ball Valve-FlareSchraderlnsulated - 58
Condensing unit wall mounting brackets (set of 2) - 440 lb capacity painted steel NOTE CWMB1 IVIU and PU outdoor units Installer is responsible to select and provide suitable hardware and materials to insure proper
mount of bracket to wall
DSD-400N M-Series DiamondBacktrade Platform Stands MUZ-GE18 I MUZ(y)-03036 I
MAC-811DS Drain socket assemblySUZ-KA18
MAC-851DS MUZ-FD0912 Drain socket
MAC-855SG M-Series Air outlet guide
MAC-856SG M-Series Air outlet guide - MXZ-3B24 I 3B30 I 4B36 NA
MAC-860DS MUZ-GE091215 I MUZ-FE0912 Drain socket
MAC-889SG M-Series Air outlet guide- MXZ-2B20NA
MAC-S99SG M-Series Air outlet guide
PAC-SG59SG-E IVIXZ-SB4SNA Air outlet guide (1 piece) I MXZ-SB48NA (Requires 2 pieces)
PAC-SG61 DS-E MXZ-8B4SNA Drain socket - connector
PAC-SG64DP-E MXZ-SB48NA Drain pan
RCMKP1CB lVI-Series Wireless Lockdown bracket for remote controller
lILTRILlTE1 All M-Series Condensing unit mounting pad 16 x 36 x 3
MITSUBISHI ELECTRIC 27
MXZ-8 Series Port Adapter chart Port Adapter Unit Port
Combinations Required Size
MXZ-2B20NA-1
2-zone combinations wi NA
A 38 x both units s12K 14
1-MAC-A454JP-E B 38 x
6+15 14
9+15 1-MAC-A454JP-E
MXZ-3B24NA
All rated 2-zone combina-NA
A 12 x tions 14
All rated 3-zone combina-NA
B 38 x tions 14
C 38 x 14
MXZ-3B30NA
2-zone combinations wi at NA
A 12 x least one unit s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
9 + 24 14
3-zone combinations wi 1-MAC-A455JP-E
all units s12K
All other rated 3-zone NA
comb
MXZ-4B36NA
2-zone combinations wi at NA
A 12 x least one un it s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
6 + 24 14
1-MAC-A456JP-E D 38 x
9 + 24 14
3-zone combinations wi at NA
least two units s12K
3-zone combinations wi 1-MAC-A454JP-E
two units15K
6+6+24 or 6+9+24 1-MAC-A456JP-E
9+9+24 1-MAC-A456JP-E
4-zone combinations wi at 1-MAC-A455JP-E
least three units s12K
6+6+15+15 1-MAC-A454JP-E
6+6+15+15 1-MAC-A454JP-E
Note When using the Pu-A24BA PCA-A24KA or PEAD-A24AA two port adapter will be needed 1-MAC-A456JP-E (12 x 58) A port or 1-PACshySG76RJ-E (38 x 58) B C and D ports and 1-PAC493PI (14 x 38)
28 JMITSUBISHI ELECTRIC
6+6+246+9+24 6+12+249+9+24 9+12+24 or 12+12+24
6+15+24 6+18+24 9+15+249+18+24 12+15+24 or 12+18+24
15+15+24 15+18+24 or 18+18+24
15+24+24 or 18+24+24
Combinations of 4 or more zones
1-PAC-SG76RJ-E
See notes for application below
2
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
See notes for application below
PORT A =38 gas x 14 liquid
PORT B =38 gas x 14 liquid
PORT C =38 gas x 14 liquid
PORT A =38 gas x 14 liquid
PORT B = 38 gas x 14 liquid
PORT C = 38 gas x 14 liquid
PORT D =38 gas x 14 liquid
PORT E =12 gas x 14 liquid
Notes for application bull Check the lineset sizes for your indoor selected models bull Select the branch box or boxes needed for your application bull Compare indoor unit lineset sizes as compared to branch
box sizes bull Connect 15K + indoor units to the larger port on the
(PAC-AKA51 BC) bull Adapt lineset size with appropriate port adapter from
above list bull When using the PU-A24BA or PEAD-A24AA two port
adapter will be needed 1-MAC-A456JP-E (12 x 58) or 1-PAC-SG76RJ-E (38 x 58) and 1-PAC493PI (14 x 38)
-fv
~ DIAMONDBACKtrade
~) BV-Series Ball Valves Model numbers
BV14FFSI BV38FFSI
LISTED 891N REFRIGERANT
BV12FFSI VALVE bull Engineered for Mini-split andBV58FFSI
Multi-split HVAC Units bull Size available 14 38 12 58
bull Full Port Designbull Fully factory assembled bull Furnace brazed and pressure tested bull 700 PSIG Rated bull Each ball valve is equipped with Schraderreg Valve
for refrigerant service bull R-410A Compatible bull Design working pressure 700 PSIG bull Temperature range bull Flare Connections
-40 0 F to +3250 F (-400 C to + 1490
C) bull Forged brass body and seal cap bull Teflonreg seals and gaskets (no synthetic a-rings) bull Seal cap design permits valve operation without
removal of seal cap bull Suitable for use with R-11 R-22 R-123 R-125
R-134A R-236FA R-4202A R-402B R-404A R-407C R-410A R-500 R-502 and R-507
bull One year limited materials and workmanship
Part Number SAE Flare
A B C 0 E F
BV14FFSI 14 619 260 180 122 142 110
BV38FFSI 38 630 267 180 122 142 110
BV12FFSI 12 651 267 180 122 142 110
BV58FFSI 58 664 267 180 128 142 110
Ball valves come With an insulation piece warranty on Ball Valves
~ DIAMONDBACKtrade
~) Platform Stands
Lift the Mitsubishi Electric Comfort Solution
outdoor unit to new heights with our Diamondback Platform Stands
bull Easy to install
bull Available for all sizes of Mr Slim outdoor units
bull Color matched to the outdoor units
Model Number DSD-400N
L 15-34 x W 3-14 x H 3-14
r
)MITSUBISHI ELECTRIC 29
~ DIAMONDBACKtrade LINESETS
~~
Twin-Tube Lineset Insulation Design
bull Balanced outside diameter for uniform coiluncoil position stability
bull Minimum 12 insulation thickness on both tubes Diamondback Advantages include the following features
bull Quick efficient and economical field installation using factory applied Twin Tube insulation and flare connections with flare nuts mounted
bull Correct lengths for reducing waste and time
bull Quality consistency and economy
bull All Diamondback Lineset tubing is tested in accordance with ASTM E243
Filter Boxes
FB Series filter boxes are available in compatible sizes for all Mr Slim horizontal ducted indoor units
FBL 1 filter boxes include 1 thick pleated MERV 8 filter(s) installed Filters are tested in accordance with ANSIASHRAE Standard 522 and Rated Class 2 under UL Standard 900
The cabinet is constructed of non-insulated 20 gauge G-60 galvanized
FBL1-1 FB Series Filter Box for SEZ-KD09NA
FBL1-2 FB Series Filter Box for SEZ-KD12KD15-NA
FBL1-3 FB Series Filter Box for SEZ-KD18NA
steel with foam gasket and provides an air-tight connection to indoor unit and access door Gasket material complies with UL 723 requirements
A screw-through cabinet design for secure attachment to indoor unit and return connection in rear is easily field-converted to bottom return
30 MITSUBISHI ELECTRIC
bull
bull
bull
bull
bull
bull
LINE-HIDE~ Put a professional finish on air-conditioning
installations with an easy-to-install modular
system that beautifies exteriors and
protects Linesets drainlines and wiring
Can be use it indoors too Meets UL94v-O for interior applications
Has snap-on covers and a full selection of couplings elbows T-joints caps and more for any application complex or simple
Offers high-quality PVC with UV inhibitors for outdoor service in all weather conditions
Can be painted with most house paints to match exterior decors
Is not just for HVAC Hide any exterior cabling piping or wiring
Available in four sizes 2-14 3 4 and 6 tubes
Download a brochure at wwwline-hidecom to find out more information
For more information on our CITY MULTI VRF product line visit our website at wwwmitsubishiprocom
_lIJrUlllln ~ ~IIII1 fInll l
~
l bull bull
JMITSUBISHI ELECTRIC 31
MXZ-8 Series Port Adapter chart Port Adapter Unit Port
Combinations Required Size
MXZ-2B20NA-1
2-zone combinations wi NA
A 38 x both units s12K 14
1-MAC-A454JP-E B 38 x
6+15 14
9+15 1-MAC-A454JP-E
MXZ-3B24NA
All rated 2-zone combina-NA
A 12 x tions 14
All rated 3-zone combina-NA
B 38 x tions 14
C 38 x 14
MXZ-3B30NA
2-zone combinations wi at NA
A 12 x least one unit s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
9 + 24 14
3-zone combinations wi 1-MAC-A455JP-E
all units s12K
All other rated 3-zone NA
comb
MXZ-4B36NA
2-zone combinations wi at NA
A 12 x least one un it s12K 14
2-zone combinations wi 1-MAC-A454JP-E
B 38 x both units 15K 14
1-MAC-A456JP-E C 38 x
6 + 24 14
1-MAC-A456JP-E D 38 x
9 + 24 14
3-zone combinations wi at NA
least two units s12K
3-zone combinations wi 1-MAC-A454JP-E
two units15K
6+6+24 or 6+9+24 1-MAC-A456JP-E
9+9+24 1-MAC-A456JP-E
4-zone combinations wi at 1-MAC-A455JP-E
least three units s12K
6+6+15+15 1-MAC-A454JP-E
6+6+15+15 1-MAC-A454JP-E
Note When using the Pu-A24BA PCA-A24KA or PEAD-A24AA two port adapter will be needed 1-MAC-A456JP-E (12 x 58) A port or 1-PACshySG76RJ-E (38 x 58) B C and D ports and 1-PAC493PI (14 x 38)
28 JMITSUBISHI ELECTRIC
6+6+246+9+24 6+12+249+9+24 9+12+24 or 12+12+24
6+15+24 6+18+24 9+15+249+18+24 12+15+24 or 12+18+24
15+15+24 15+18+24 or 18+18+24
15+24+24 or 18+24+24
Combinations of 4 or more zones
1-PAC-SG76RJ-E
See notes for application below
2
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
1-PAC-SG76RJ-E
See notes for application below
PORT A =38 gas x 14 liquid
PORT B =38 gas x 14 liquid
PORT C =38 gas x 14 liquid
PORT A =38 gas x 14 liquid
PORT B = 38 gas x 14 liquid
PORT C = 38 gas x 14 liquid
PORT D =38 gas x 14 liquid
PORT E =12 gas x 14 liquid
Notes for application bull Check the lineset sizes for your indoor selected models bull Select the branch box or boxes needed for your application bull Compare indoor unit lineset sizes as compared to branch
box sizes bull Connect 15K + indoor units to the larger port on the
(PAC-AKA51 BC) bull Adapt lineset size with appropriate port adapter from
above list bull When using the PU-A24BA or PEAD-A24AA two port
adapter will be needed 1-MAC-A456JP-E (12 x 58) or 1-PAC-SG76RJ-E (38 x 58) and 1-PAC493PI (14 x 38)
-fv
~ DIAMONDBACKtrade
~) BV-Series Ball Valves Model numbers
BV14FFSI BV38FFSI
LISTED 891N REFRIGERANT
BV12FFSI VALVE bull Engineered for Mini-split andBV58FFSI
Multi-split HVAC Units bull Size available 14 38 12 58
bull Full Port Designbull Fully factory assembled bull Furnace brazed and pressure tested bull 700 PSIG Rated bull Each ball valve is equipped with Schraderreg Valve
for refrigerant service bull R-410A Compatible bull Design working pressure 700 PSIG bull Temperature range bull Flare Connections
-40 0 F to +3250 F (-400 C to + 1490
C) bull Forged brass body and seal cap bull Teflonreg seals and gaskets (no synthetic a-rings) bull Seal cap design permits valve operation without
removal of seal cap bull Suitable for use with R-11 R-22 R-123 R-125
R-134A R-236FA R-4202A R-402B R-404A R-407C R-410A R-500 R-502 and R-507
bull One year limited materials and workmanship
Part Number SAE Flare
A B C 0 E F
BV14FFSI 14 619 260 180 122 142 110
BV38FFSI 38 630 267 180 122 142 110
BV12FFSI 12 651 267 180 122 142 110
BV58FFSI 58 664 267 180 128 142 110
Ball valves come With an insulation piece warranty on Ball Valves
~ DIAMONDBACKtrade
~) Platform Stands
Lift the Mitsubishi Electric Comfort Solution
outdoor unit to new heights with our Diamondback Platform Stands
bull Easy to install
bull Available for all sizes of Mr Slim outdoor units
bull Color matched to the outdoor units
Model Number DSD-400N
L 15-34 x W 3-14 x H 3-14
r
)MITSUBISHI ELECTRIC 29
~ DIAMONDBACKtrade LINESETS
~~
Twin-Tube Lineset Insulation Design
bull Balanced outside diameter for uniform coiluncoil position stability
bull Minimum 12 insulation thickness on both tubes Diamondback Advantages include the following features
bull Quick efficient and economical field installation using factory applied Twin Tube insulation and flare connections with flare nuts mounted
bull Correct lengths for reducing waste and time
bull Quality consistency and economy
bull All Diamondback Lineset tubing is tested in accordance with ASTM E243
Filter Boxes
FB Series filter boxes are available in compatible sizes for all Mr Slim horizontal ducted indoor units
FBL 1 filter boxes include 1 thick pleated MERV 8 filter(s) installed Filters are tested in accordance with ANSIASHRAE Standard 522 and Rated Class 2 under UL Standard 900
The cabinet is constructed of non-insulated 20 gauge G-60 galvanized
FBL1-1 FB Series Filter Box for SEZ-KD09NA
FBL1-2 FB Series Filter Box for SEZ-KD12KD15-NA
FBL1-3 FB Series Filter Box for SEZ-KD18NA
steel with foam gasket and provides an air-tight connection to indoor unit and access door Gasket material complies with UL 723 requirements
A screw-through cabinet design for secure attachment to indoor unit and return connection in rear is easily field-converted to bottom return
30 MITSUBISHI ELECTRIC
bull
bull
bull
bull
bull
bull
LINE-HIDE~ Put a professional finish on air-conditioning
installations with an easy-to-install modular
system that beautifies exteriors and
protects Linesets drainlines and wiring
Can be use it indoors too Meets UL94v-O for interior applications
Has snap-on covers and a full selection of couplings elbows T-joints caps and more for any application complex or simple
Offers high-quality PVC with UV inhibitors for outdoor service in all weather conditions
Can be painted with most house paints to match exterior decors
Is not just for HVAC Hide any exterior cabling piping or wiring
Available in four sizes 2-14 3 4 and 6 tubes
Download a brochure at wwwline-hidecom to find out more information
For more information on our CITY MULTI VRF product line visit our website at wwwmitsubishiprocom
_lIJrUlllln ~ ~IIII1 fInll l
~
l bull bull
JMITSUBISHI ELECTRIC 31
-fv
~ DIAMONDBACKtrade
~) BV-Series Ball Valves Model numbers
BV14FFSI BV38FFSI
LISTED 891N REFRIGERANT
BV12FFSI VALVE bull Engineered for Mini-split andBV58FFSI
Multi-split HVAC Units bull Size available 14 38 12 58
bull Full Port Designbull Fully factory assembled bull Furnace brazed and pressure tested bull 700 PSIG Rated bull Each ball valve is equipped with Schraderreg Valve
for refrigerant service bull R-410A Compatible bull Design working pressure 700 PSIG bull Temperature range bull Flare Connections
-40 0 F to +3250 F (-400 C to + 1490
C) bull Forged brass body and seal cap bull Teflonreg seals and gaskets (no synthetic a-rings) bull Seal cap design permits valve operation without
removal of seal cap bull Suitable for use with R-11 R-22 R-123 R-125
R-134A R-236FA R-4202A R-402B R-404A R-407C R-410A R-500 R-502 and R-507
bull One year limited materials and workmanship
Part Number SAE Flare
A B C 0 E F
BV14FFSI 14 619 260 180 122 142 110
BV38FFSI 38 630 267 180 122 142 110
BV12FFSI 12 651 267 180 122 142 110
BV58FFSI 58 664 267 180 128 142 110
Ball valves come With an insulation piece warranty on Ball Valves
~ DIAMONDBACKtrade
~) Platform Stands
Lift the Mitsubishi Electric Comfort Solution
outdoor unit to new heights with our Diamondback Platform Stands
bull Easy to install
bull Available for all sizes of Mr Slim outdoor units
bull Color matched to the outdoor units
Model Number DSD-400N
L 15-34 x W 3-14 x H 3-14
r
)MITSUBISHI ELECTRIC 29
~ DIAMONDBACKtrade LINESETS
~~
Twin-Tube Lineset Insulation Design
bull Balanced outside diameter for uniform coiluncoil position stability
bull Minimum 12 insulation thickness on both tubes Diamondback Advantages include the following features
bull Quick efficient and economical field installation using factory applied Twin Tube insulation and flare connections with flare nuts mounted
bull Correct lengths for reducing waste and time
bull Quality consistency and economy
bull All Diamondback Lineset tubing is tested in accordance with ASTM E243
Filter Boxes
FB Series filter boxes are available in compatible sizes for all Mr Slim horizontal ducted indoor units
FBL 1 filter boxes include 1 thick pleated MERV 8 filter(s) installed Filters are tested in accordance with ANSIASHRAE Standard 522 and Rated Class 2 under UL Standard 900
The cabinet is constructed of non-insulated 20 gauge G-60 galvanized
FBL1-1 FB Series Filter Box for SEZ-KD09NA
FBL1-2 FB Series Filter Box for SEZ-KD12KD15-NA
FBL1-3 FB Series Filter Box for SEZ-KD18NA
steel with foam gasket and provides an air-tight connection to indoor unit and access door Gasket material complies with UL 723 requirements
A screw-through cabinet design for secure attachment to indoor unit and return connection in rear is easily field-converted to bottom return
30 MITSUBISHI ELECTRIC
bull
bull
bull
bull
bull
bull
LINE-HIDE~ Put a professional finish on air-conditioning
installations with an easy-to-install modular
system that beautifies exteriors and
protects Linesets drainlines and wiring
Can be use it indoors too Meets UL94v-O for interior applications
Has snap-on covers and a full selection of couplings elbows T-joints caps and more for any application complex or simple
Offers high-quality PVC with UV inhibitors for outdoor service in all weather conditions
Can be painted with most house paints to match exterior decors
Is not just for HVAC Hide any exterior cabling piping or wiring
Available in four sizes 2-14 3 4 and 6 tubes
Download a brochure at wwwline-hidecom to find out more information
For more information on our CITY MULTI VRF product line visit our website at wwwmitsubishiprocom
_lIJrUlllln ~ ~IIII1 fInll l
~
l bull bull
JMITSUBISHI ELECTRIC 31
~ DIAMONDBACKtrade LINESETS
~~
Twin-Tube Lineset Insulation Design
bull Balanced outside diameter for uniform coiluncoil position stability
bull Minimum 12 insulation thickness on both tubes Diamondback Advantages include the following features
bull Quick efficient and economical field installation using factory applied Twin Tube insulation and flare connections with flare nuts mounted
bull Correct lengths for reducing waste and time
bull Quality consistency and economy
bull All Diamondback Lineset tubing is tested in accordance with ASTM E243
Filter Boxes
FB Series filter boxes are available in compatible sizes for all Mr Slim horizontal ducted indoor units
FBL 1 filter boxes include 1 thick pleated MERV 8 filter(s) installed Filters are tested in accordance with ANSIASHRAE Standard 522 and Rated Class 2 under UL Standard 900
The cabinet is constructed of non-insulated 20 gauge G-60 galvanized
FBL1-1 FB Series Filter Box for SEZ-KD09NA
FBL1-2 FB Series Filter Box for SEZ-KD12KD15-NA
FBL1-3 FB Series Filter Box for SEZ-KD18NA
steel with foam gasket and provides an air-tight connection to indoor unit and access door Gasket material complies with UL 723 requirements
A screw-through cabinet design for secure attachment to indoor unit and return connection in rear is easily field-converted to bottom return
30 MITSUBISHI ELECTRIC
bull
bull
bull
bull
bull
bull
LINE-HIDE~ Put a professional finish on air-conditioning
installations with an easy-to-install modular
system that beautifies exteriors and
protects Linesets drainlines and wiring
Can be use it indoors too Meets UL94v-O for interior applications
Has snap-on covers and a full selection of couplings elbows T-joints caps and more for any application complex or simple
Offers high-quality PVC with UV inhibitors for outdoor service in all weather conditions
Can be painted with most house paints to match exterior decors
Is not just for HVAC Hide any exterior cabling piping or wiring
Available in four sizes 2-14 3 4 and 6 tubes
Download a brochure at wwwline-hidecom to find out more information
For more information on our CITY MULTI VRF product line visit our website at wwwmitsubishiprocom
_lIJrUlllln ~ ~IIII1 fInll l
~
l bull bull
JMITSUBISHI ELECTRIC 31
bull
bull
bull
bull
bull
bull
LINE-HIDE~ Put a professional finish on air-conditioning
installations with an easy-to-install modular
system that beautifies exteriors and
protects Linesets drainlines and wiring
Can be use it indoors too Meets UL94v-O for interior applications
Has snap-on covers and a full selection of couplings elbows T-joints caps and more for any application complex or simple
Offers high-quality PVC with UV inhibitors for outdoor service in all weather conditions
Can be painted with most house paints to match exterior decors
Is not just for HVAC Hide any exterior cabling piping or wiring
Available in four sizes 2-14 3 4 and 6 tubes
Download a brochure at wwwline-hidecom to find out more information
For more information on our CITY MULTI VRF product line visit our website at wwwmitsubishiprocom
_lIJrUlllln ~ ~IIII1 fInll l
~