minimum display data sht1

3
HIGH SENSITIVITY ASPIRATING SMOKE DETECTOR HIGH SENSITIVITY ASPIRATING SMOKE DETECTOR Volt-free Fire and Fault relay outputs are available for remote monitoring by local fire detection or BMS systems. Each detector is provided with 3 pairs of remote control input terminals. The inputs may be configured for number of functions, see technical documentation for full details. Applications & Acceptance Stratos detectors have been successfully applied in tens of thousands of applications worldwide, ranging from Clean Rooms to Casinos. Options Available n APIC™ Addressable Protocol Interface Cards available for most industry signalling protocols. n Command Module available for central monitoring and display. n SenseNet computerised remote monitoring compatibl e - up to 127 detectors per loop. n Remote Display units available. n A lower cost Minimum Display option is available. n Suitable for Strat os-MatrixScan, a patented software system which provides virtual addressable location detection - e.g. 10 physical detectors would provide up to 45 unique addressable locations. Approvals n Approved/listed by most major international fire protection certification agencies. (contact AirSense Technology for latest details). Key Features n Ecomnomy version HSSD Standard detector in rugged sheet steel enclosure. n Display offers indication of alarm, fault and normal operation. n Programmable by RS 485 serial connection or Command Module. n High sensitivity provided by laser based forward light scatter for reliable early warning. n Unique ClassiFire ® Perceptive Artificial Intelligence system that dynamically adjusts the detector’s operating parameters, allowing for day to day changes in the protected environment and system contamination. n Unwanted alarms from dust are avoided using patented Dual Technology LDD 3D 3 Laser Dust Discriminatio n and elimination system. n 4 sampling pipes, up to 250m maximum total length. n RS485 communicatio ns built in as standard for networking and remote communications. n LPCB approved for up to 100 sampling holes. Description Stratos-HSSD has unmatched sensitivity potential, providing the very earliest warning of incipient fire with minimum rate of nuisance alarms. ClassiFire Perceptive Artificial Intelli gence ensures that the detector operates at optimum sensitivity for the protected environment, without the need for complex setup. This means the detector will configure itself to provide high sensitivity in a computer room or reduced sensitivity in a smoky area. Minimum Display 

Upload: sayed-hashem

Post on 04-Mar-2016

228 views

Category:

Documents


0 download

DESCRIPTION

fire

TRANSCRIPT

Page 1: Minimum Display Data Sht1

7/21/2019 Minimum Display Data Sht1

http://slidepdf.com/reader/full/minimum-display-data-sht1 1/2

HIGH SENSITIVITY ASPIRATING SMOKE DETECTOR HIGH SENSITIVITY ASPIRATING SMOKE DETECTOR

Volt-free Fire and Fault relay outputs are available for remote monitoring by local firedetection or BMS systems. Each detector is provided with 3 pairs of remote controlinput terminals. The inputs may be configured for number of functions, see technicaldocumentation for full details.

Applications & Acceptance

Stratos detectors have been successfully applied in tens of thousands of applicationsworldwide, ranging from Clean Rooms to Casinos.

Options Available

nAPIC™ Addressable Protocol Interface Cards available for most industrysignalling protocols.nCommand Module available for central monitoring and display.nSenseNet computerised remote monitoring compatible - up to 127 detectors perloop.nRemote Display units available.nA lower cost Minimum Display option is available.nSuitable for Stratos-MatrixScan, a patented software system which providesvirtual addressable location detection - e.g. 10 physical detectors would provideup to 45 unique addressable locations.

Approvals

nApproved/listed by most major international fire protection certificationagencies. (contact AirSense Technology for latest details).

Key FeaturesnEcomnomy version HSSD Standard detector in rugged sheet steel enclosure.nDisplay offers indication of alarm, fault and normal operation.nProgrammable by RS 485 serial connection or Command Module.nHigh sensitivity provided by laser based forward light scatter for reliable earlywarning.nUnique ClassiFire® Perceptive Artificial Intelligence system that dynamicallyadjusts the detector’s operating parameters, allowing for day to day changes in theprotected environment and system contamination.

nUnwanted alarms from dust are avoided using patented Dual Technology LDD 3D3

Laser Dust Discrimination and elimination system.n4 sampling pipes, up to 250m maximum total length.nRS485 communications built in as standard for networking and remotecommunications.nLPCB approved for up to 100 sampling holes.

Description

Stratos-HSSD has unmatched sensitivity potential, providing the very earliest warningof incipient fire with minimum rate of nuisance alarms.

ClassiFire Perceptive Artificial Intelligence ensures that the detector operates at optimumsensitivity for the protected environment, without the need for complex setup. Thismeans the detector will configure itself to provide high sensitivity in a computer room orreduced sensitivity in a smoky area.

Minimum Display

Page 2: Minimum Display Data Sht1

7/21/2019 Minimum Display Data Sht1

http://slidepdf.com/reader/full/minimum-display-data-sht1 2/2

O R D E R I N G I N F O R M A T I O N

Part No. Description30710 Minimum Display Detector

30699 Replacement Dust Separator

30220 Setup and Servicing Software (free of charge)

30419 Serial PC Lead

30821 PS25 Power Supply

140.0

180.0

340.0120.0

6mm dia.3 places

CLEARANCE AREA FOR DETECTOR

200.0

Air Sense Technology Limited71 Knowl Piece • Wilbury Way

Hitchin • Hertfordshire • SG4 0TYTel: +44 (0)1462 440666 • Fax: +44 (0)1462 440888

e-mail: [email protected] • www.airsensetechnology.com

Supply Voltage 21.6V - 26.4V DCCurrent consumption 450mA @ 24V DC at fan speed 8Size 427W x 372H x 95D

Weight 5.2kgOperating temperature range -10 to +38°C (UL268)

-10 to + 60°C (CEA4022)Operating humidity range 0 - 90% non-condensingMeasurement range (%Obs/m) 0.0015% to 25%

Detection principle Laser light scattering massdetection and particle evaluation

Particle sensitivity range 0.003µ to 10µDust discrimination principle 3D 3 Laser Dust Discrimination (LDD)Recommended max. single 100msampling pipe lengthSampling pipe diameter 3/4” nominal bore

(27mm O/D)

Total sampling pipe maximum 250m @ 80 sampling holes -200m @ 100 sampling holes

Alarm levels 4 (Aux, Pre-alarm, Fire 1 and Fire 2)Laser chamber service intervals Greater than 10 years

(dependent on environment)Laser lifetime (MTTF) Greater than 1000 yearsProgramming Front panel, Command Module or

PC via RS232/RS485

Network data bus RS485Maximum data bus length 1.2 kmbetween detectorsIP rating IP50Sampling pipe inlets 4 on top, 4 at rear Exhaust air pipe outlets 1 on top, 1 at rear

S h or t f or m d

a t a s h e e t Mi ni m

um Di s pl a y

I s s u e 1

J a n‘ 0

5

S P E C I F I C A T I O N S S T R A T O S - H S S D M i n i m u m D i s p l a y

Data storage units

Prison cells

Plant rooms

Air conditioning units

Equipment racks

Computer rooms

Air duct protection

Heritage property protection

Critical equipment

Anti-smoking enforcement

Motor rooms

A P P L I C A T I O N S

Dimensions Stratos-HSSDMounting plate