VRFOUTDOOR UNITS
Mini VRF series
Mini VRF Full DC Inverter series units is a system dedicated for family houses, offices and other small commercial sites. Depending on the size of outdoor unit, it is possible to connect from 6 to 15 indoor units to one system.Individual control provides independent setting of required air parameters in each room.
-
73
BROAD FUNCTIONALITYMAIN FEATURES
Outdoor units capacity range from 12.0 to 45.0 kW. Ideal for application in residences, family houses, small offices and other public utility facilities.
Mini VRF system allows to connect up to 15 indoor units to one outdoor unit. Total indoor units capacity can remain in range 50-130% of outdoor unit capacity. Application of the whole lineup of the VRF indoor units ensures high flexibility in use, and independent control guarantees comfort in each room.
FLEXIBLE CONFIGURATION
WIDE OUTDOOR UNITS LINEUP
14/18 kW 22.4/26.0/40.0/45.0 kW
Possible connections:• Max. 6 indoor units for a 14.0 kW outdoor unit• Max. 9 indoor units for a 18.0 kW outdoor unit• Max. 11 indoor units for a 22.4 kW outdoor unit• Max. 12 indoor units for a 26.0 kW outdoor unit• Max. 14 indoor units for a 40.0 kW outdoor unit• Max. 15 indoor units for a 45.0 kW outdoor unit
-
COOLING MODE
HEATING MODE
Outdoor temperature
Outdoor temperature
Outdoor temperature
Height difference betweenoutdoor unit and indoor units
Maximum piping length
Distance from the first branch jointin the system to the farthest indoor unit
Distance from indoor unit tothe nearest branch joint
Height difference betweenindoor units
74
Mini VRF system ensures stable operation in extreme temperatures, from -15°C up to +48°C.
* The above ranges regard 14.0-26.0 kW devices.
WIDE OPERATION RANGE
LONG REFRIGERANT PIPING – FLEXIBLE DESIGN
Allowable value (m)
14/18 kW 22.4/26.0 kW 40.0/45.0 kW
Pipinglength
Total piping length *(actual) 100 120 250
Maximum length (L)Actual length 60 60 100
Equivalent length 70 70 120
Heightdifference
Distance from the first branch joint in the system to the farthest indoor unit 20 20 40
Distance from indoor unit to the nearest branch joint 15 15 15
Between indoor and outdoor unitsOutdoor unit stated above 30 30 30
Outdoor unit stated below 20 20 20
Between indoor units 8 8 8
-
High performance, inner grooved pipesof the heat exchanger with large heat exchange surface
New structure Previous construction Hydrophilic fins+ inner grooved copper pipes
High performance, inner grooved pipesof the heat exchanger with large heat exchange surface
New structure Previous construction Hydrophilic fins+ inner grooved copper pipes
High performance, inner grooved pipesof the heat exchanger with large heat exchange surface
New structure Previous construction Hydrophilic fins+ inner grooved copper pipes
75
HIGH EFFICIENCYMAIN FEATURES
Inside the specially designed heat exchanger there are used fins with greater heat exchange surface and reduced airflow resistance. Fins outside surface is covered with hydrophilic coating. The copper pipes internal surfaces have a special groove embossed, which improves heat transfer on the refrigerant side. These solutions, together with the innovative method of exchanger pipes connection, ensure the highest heat exchange efficiency.
High-performance heat exchanger, top class inverter compressor and DC Inverter fan motor employed in the Mini VRF series air-conditioning units, enables achieving energy efficiency coefficients.
HIGH ENERGY EFFICIENCY COEFFICIENTS - EER AND COP
HIGH-PERFORMANCE HEAT EXCHANGER
EERCOP
14.0 kW
3.543.70
18.0 kW
3.30
3.80
22.4 kW
3.29
4.15
26.0 kW
3.42
4.19
40.0 kW
3.36
4.05
45.0 kW
3.31
3.94
Reduced airflow
resistance
-
Startingcurrent
PipetensionConstant capacity compressor:5-7 times higher current
Constant capacity compressor:3 fold increase
Inventer
Inventer: almost the same as during normal operation
Uncomfortable conditions(energy losses)
Without Inverter -high temperature �uctuations
Inverter -moderate temperature �uctuations
Uncomfortable conditions(energy losses)
Comfortable conditions
Intelligent defrosting
Fastdefrosting
Fastdefrosting
Heating 85 minDefrosting 4 min
Time (min)
Ther
moc
oupl
e te
mpe
ratu
re (o
C)
Ther
moc
oupl
e te
mpe
ratu
re (o
C)
Time (min)
Heating 50 minDefrosting 10 minNormal defrosting
76
HIGH COMFORTMAIN FEATURES
Inverter compressor with the soft start function limits temporary overloads and voltage drops in the building electricity system. High performance inverter compressors achieve rated capacity in a very short time, what directly influences the air-conditioned rooms cooling down or heating up time. Smaller temperature fluctuations guarantee instant feeling of comfort.
ADVANCED DEFROSTING TECHNOLOGY
A specially designed defrosting algorithm provides the removal of ice from outdoor unit heat exchanger in optimal time. Because the defrosting time depends on actual, outside conditions, the heating intervals are reduced to the minimum necessary, what has a significant influence on keeping thermal comfort in the heated rooms.
SOFT START, PRECISE TEMPERATURE CONTROL
-
P Q E P Q E P Q E P Q E
P Q E X Y E X Y E
77
SIMPLE INSTALLATION AND MAINTENANCEMAIN FEATURES
Outdoor unit compact casing leads to considerable savings of the installation space. Small dimensions and low weight makes it possible to install the unit even on the wall brackets. In comparison to traditional split type air-conditioners, the Mini VRF system replaces from several to dozens of smaller units, without affecting current aesthetic of the building.
One, common communication cable. Depending on the requirements, the central controller CCM03 can be connected to the XYE terminal from the outdoor or indoor units side. This solution simplifies and lowers the costs of system wiring.
Compact size and limited weight facilitate transport and installation, reduce ceiling and structure loads. Now, only with help of a forklift and an elevator, the units can be placed on the roof of a high building.
COMPACT CASING - EFFECTIVE USE OF SPACE
INSTALLATION SPACE SAVING - BUILDING AESTHETIC IS MAINTAINED
SIMPLIFIED CONNECTION OF THE COMMUNICATION LINE
Easy transport
Each indoor unit address canbe checked and modified withuse of the wireless controller.
• PQE & XYE, now it takes only one PQE communication cable both for communication between indoor and outdoor units as well as for network communication.
• Two-way communication - the central controller can be connected both from the outdoor unit and indoor unit side.
-
Outdoor unit can assign addresses to indoor unit.
Shielded signal cable
Front side Rigth side Back side Bottom side
Front
Right
Back
Bottom
78
Forced cooling switch enables starting the outdoor unit in cooling mode in any conditions, which facilitate refrigerant charge in case of such need.Self-diagnosis function detects system malfunctions and displays adequate error codes, which makes it considerably easier to perform troubleshooting.
The outdoor unit can automatically assign addresses to indoor units. Indoor units addresses can be checked and in case of need modified with use of an infrared remote controller.
Refrigerant system pipes and electric wires can be lead in any direction, thus considerably facilitating installation works and affects the aesthetic of the finish.
AUTOMATIC ADDRESS SETTING
CONVENIENT INSTALLATION
EASY MAINTENANCE
-
Concentrated winding
Compressor capacityNew DC motor with concentrated windingDC motor with distributed winding
Rotor speed (s-1)
Rot
or p
erfo
rman
ce
Distributed winding
79
TECHNOLOGIESMAIN FEATURES
Application of new inverter technology and DC fan motor allow to achieve high capacity and energy saving, significantly reducing energy consumption during continuous operation, while ensuring stable temperature conditions in the room.
STRONG MAGNETS PROVIDE HIGH TORQUE AND CAPACITY
QUIET FAN WITH DC MOTOR
Special guard design and properly profiled fan blades significantly reduces noise while keeping large airflow.
FULL DC INVERTER – HIGH EFFICIENCY COMPRESSOR
Twin rotaryDC compressor
High performance DC motor• new motor core• high density neodymium magnet• concentrated stator• wide range of operational frequency
Better balance and very low vibrations• twin eccentric discs• two balance weights
More stable moving parts• optimal shaft fitting• optimisation of compressor drive technology• extremely durable bearings• compact construction
DC Panasonic fan motor• fan speed wide adjustment range• lower noise• lower energy consumption
Cap
acity
(%)
Motor rotation speed (rpm)
DC motor efficiency(comparison with conventional alternating current motor)
New fan shield New and larger propeller
DC motor
Increaseby approx.20%
Increase by approx. 20%
AC motor
-
A
C
1650
475
450
500
540
B 505
A
C
1650
475
450
500
540
B 505
80
EXTERNAL UNITSDIMENSIONS
14.0, 18.0 KW
40.0, 45.0 KW
22.4, 26.0 kW
Model A B C
40kW 175 505 1360
45kW 225 555 1460
-
81
TECHNICAL DATA
14.0~18.0 kWModel MDV-V140W/DRN1 MDV-V180W/DRN1
Power supply V/phase/Hz 380~415/3N/50 380~415/3N/50
Cooling
Rated capacity kW 14.0 17.5
Rated power input W 3950 5300
EER kW/ kW 3.54 3.30
Heating
Rated capacity kW 15.4 19.0
Rated power input W 4160 5000
COP kW/ kW 3.70 3.80
Admissible efficiency of internal units % 45-130 45-130
Maximum connectable indoor units quantity 6 9
Compressor - DC Inverter
Type Rotary Rotary
Brand MITSUBISHI MITSUBISHI
Fan motor Type DC motor DC motor
FanType Axial fan Axial fan
Diameter mm 508 508
Heat exchanger Type Aluminium with hydrophilic coating
Airflow m3/min 100 113
Sound pressure level dB(A) 57 59
Dimensions and weights
Net dimensions (width x height x depth) mm 900 x 1327 x 400 900 x 1327 x 400
Transport dimensions (width x height x depth) mm 1030 x 1456 x 435 1030 x 1456 x 435
Net / gross weight kg 95/103 107/118
RefrigerantType R410A R410A
Charge g 3900 4500
Expansion element EXV
Cooling pipes
Liquid pipe/Gas pipe mm Ø9.52/Ø15.9 Ø9.52/Ø19.1
Maximum length of pipes m 100 100
Maximum height difference m 30 30
Electrical cablesPower supply cable mm2 5 conductors x 2.5 5 conductors x 2.5
Communication cable mm2 3 x 0.75 screened conductors 3 x 0.75 screened conductors
Fuse recommended A 25 25
Ambient temperature
Cooling °C -15 ~ 48 -15 ~ 48
Heating °C -15 ~ 27 -15 ~ 27
Note:The capacity is based on the following conditions:Cooling: indoor temperature 27°C DB/19°C WB; outdoor temperature 35°C DBHeating: indoor temperature 20°C DB/15°C WB; outdoor temperature 7°C DB.Refrigerant piping length 7.5 m at the height difference of 0 m.DB - dry bulb, WB - wet bulbSound pressure level measured in a reverberation chamber in a distance of 1 m from the unit front. Microphone is placed 1.3 m above the floor.Main pipelines diameters are provided for the calculated conditions and assuming 100% oversizing of the outdoor unit. Actual diameters should be determined on the basis of the data included in the technical documentation or with use of the selection software.
-
82
TECHNICAL DATA
22.4~26.0 kWModel MDV-V224W/DRN1 MDV-V260W/DRN1
Power supply V/phase/Hz 380~415/3N/50 380~415/3N/50
Cooling
Rated capacity kW 22.4 26.0
Rated power input W 6800 7600
EER kW/ kW 3.29 3.42
Heating
Rated capacity kW 24.5 28.5
Rated power input W 5900 6800
COP kW/ kW 4.15 4.19
Admissible efficiency of internal units % 50-130 50-130
Maximum connectable indoor units quantity 11 12
Compressor - DC Inverter
Type Rotary Rotary
Brand MITSUBISHI MITSUBISHI
Fan motor Type DC motor DC motor
FanType Axial fan Axial fan
Diameter mm 560 560
Heat exchanger Type Aluminium with hydrophilic coating
Airflow m3/min 175 175
Sound pressure level dB(A) 59 60
Dimensions and weights
Net dimensions (width x height x depth) mm 1120×1558×400 1120x1558x400
Shipping dimensions (width x height x depth) mm 1270×1575×480 1270x1575x480
Net / gross weight kg 146.5/162.5 147/163
RefrigerantType R410A R410A
Charge g 6200 6200
Expansion element EXV
Cooling pipes
Liquid pipe/Gas pipe mm Ø9.52/Ø19.1 Ø9.52/Ø22.2
Maximum length of pipes m 120 120
Maximum height difference m 30 30
Electrical cablesPower supply cable mm2 5 conductors x 6.0 5 conductors x 6.0
Communication cable mm2 3 x 0.75 screened conductors 3 x 0.75 screened conductors
Fuse recommended A 40 40
Ambient temperature
Cooling °C -15 ~ 48 -15 ~ 48
Heating °C -15 ~ 27 -15 ~ 27
Note:The capacity is based on the following conditions:Cooling: indoor temperature 27°C DB/19°C WB; outdoor temperature 35°C DBHeating: indoor temperature 20°C DB/15°C WB; outdoor temperature 7°C DB.Refrigerant piping length 7.5 m at the height difference of 0 m.DB - dry bulb, WB - wet bulbSound pressure level measured in a reverberation chamber in a distance of 1 m from the unit front. Microphone is placed 1.3 m above the floor.Main pipelines diameters are provided for the calculated conditions and assuming 100% oversizing of the outdoor unit. Actual diameters should be determined on the basis of the data included in the technical documentation or with use of the selection software.
-
83
TECHNICAL DATA
40.0~45.0 kWModel MDV-V400W/DRN1 MDV-V450W/DRN1
Power supply V/phase/Hz 380~415/3N/50 380~415/3N/50
Cooling
Rated capacity kW 40.0 45.0
Rated power input W 11900 13600
EER kW/ kW 3.36 3.31
Heating
Rated capacity kW 45.0 50.0
Rated power input W 11100 12700
COP kW/ kW 4.05 3.94
Admissible efficiency of internal units % 50-130 50-130
Maximum connectable indoor units quantity 14 15
Compressor - DC Inverter
Type Rotary Rotary
Brand MITSUBISHI MITSUBISHI
Fan motor Type DC motor + AC DC motor + AC
FanType Axial fan Axial fan
Diameter mm 700 700
Heat exchanger Type Aluminium with hydrophilic coating
Airflow m3/min 276 276
Sound pressure level dB(A) 62 62
Dimensions and weights
Net dimensions (width x height x depth) mm 1360x1650x540 1460x1650x540
Transport dimensions (width x height x depth) mm 1450x1785x560 1550x1785x560
Net / gross weight kg 240/260 275/290
RefrigerantType R410A R410A
Charge g 9000 12000
Expansion element EXV
Cooling pipes
Liquid pipe/Gas pipe mm Ø12.7/Ø22.2 Ø12.7/Ø25.4
Maximum length of pipes m 250 250
Maximum height difference m 30 30
Electrical cablesPower supply cable mm2 5 conductors x 10.0 5 conductors x 10.0
Communication cable mm2 3 x 0.75 screened conductors 3 x 0.75 screened conductors
Fuse recommended A 70A 90A
Ambient temperature
Cooling °C -5 ~ 48 -5 ~ 48
Heating °C -15 ~ 25 -15 ~ 24
Note:The capacity is based on the following conditions:Cooling: indoor temperature 27°C DB/19°C WB; outdoor temperature 35°C DBHeating: indoor temperature 20°C DB/15°C WB; outdoor temperature 7°C DB.Refrigerant piping length 7.5 m at the height difference of 0 m.DB - dry bulb, WB - wet bulbSound pressure level measured in a reverberation chamber in a distance of 1 m from the unit front. Microphone is placed 1.3 m above the floor.Main pipelines diameters are provided for the calculated conditions and assuming 100% oversizing of the outdoor unit. Actual diameters should be determined on the basis of the data included in the technical documentation or with use of the selection software.