milli axon basin set · 5 mm. locknut plastic washer. 3. install assembly into basin top, ensure...

2
MILLI AXON BASIN SET CLEANING RECOMMENDATIONS We recommend the use of soapy water or approved cleaners. This product should not be cleaned with abrasive materials. Damage caused by any improper treatment is not covered by the product warranty- refer to Warranty Conditions. To see the complete MILLI range go to www.reece.com.au/bathrooms SPECIFICATIONS Recommended Use Domestic, hotel and commercial Finish Available Chrome Handle with Chrome Outlet Chrome/Black Handle with Black Outlet Pressure Rating Maximum continuous operating pressure 500 kPa. Note: For best performance and longer life, we recommend 150-500 kPa. Temperature Rating Maximum continuous working temperature 75 o C Suitable Hot Water Storage Tank: Yes Continuous Flow: Refer to manufacturer of continuous hot water systems Gravity Feed: No WELS Stars: 5 Flow Rate: 5lt/min Standards AS/NZS 3718 Disclaimer: listed are correct at time of publication however the manufacturer/distributor takes no responsibility for printing errors. Tech Page Version 1 AS/NZS 3718 WM-21009 PHOENIX TAPWARE page 1 of 2 The more stars the more water efficient WATER RATING www.waterrating.gov.au In accordance with AS/NZS 6400 Licence No. 0133 Phoenix Industries Pty Ltd 5.0 litres per minute

Upload: others

Post on 29-May-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: MILLI AXON BASIN SET · 5 mm. Locknut Plastic Washer. 3. Install assembly into basin top, ensure O-rings on Tee Piece are not damaged as they enter the outlet tail. Adjust Locknuts

MILLI AXONBASIN SET

CLEANING RECOMMENDATIONSWe recommend the use of soapy water or approved cleaners. This product should not be cleaned with abrasive materials. Damage caused by any improper treatment is not covered by the product warranty- refer to Warranty Conditions. To see the complete MILLI range go to

www.reece.com.au/bathrooms

SPECIFICATIONSRecommended Use Domestic, hotel and commercial

Finish Available Chrome Handle with Chrome OutletChrome/Black Handle with Black Outlet

Pressure Rating Maximum continuous operating pressure 500 kPa.

Note: For best performance and longer life, we recommend 150-500 kPa.

Temperature Rating Maximum continuous working temperature 75 oC

Suitable Hot Water Storage Tank: YesContinuous Flow: Refer to manufacturer of continuous hot water systemsGravity Feed: No

WELS Stars: 5 Flow Rate: 5lt/min

Standards AS/NZS 3718

Disclaimer:

listed are correct at time of publication however the manufacturer/distributor takes no responsibility for printing errors.

Tech Page Version 1AS/NZS 3718

WM-21009PHOENIX TAPWARE

page 1 of 2

The more stars the more water efficient

WATER RATINGwww.waterrating.gov.au

In accordance with AS/NZS 6400

Licence No. 0133Phoenix Industries Pty Ltd

5.0 litres per minute

Page 2: MILLI AXON BASIN SET · 5 mm. Locknut Plastic Washer. 3. Install assembly into basin top, ensure O-rings on Tee Piece are not damaged as they enter the outlet tail. Adjust Locknuts

MILLI AXONBASIN SET

Plumbers, please ensure a copy of the installation instructions is left with the end user for future reference

WATER SUPPLY REQUIREMENTS

Maximum hot watertemperature

75

550 KPa Max.150 KPa Min.

Recommended WorkingPressure

Note: -If the pressure exceeds or is likely to exceed 550kpa, an approved pressure limiting device must be installed.- Flush out all pipe work prior to installation.- If the water temperature exceeds 75°C, an approved tempering valve must be �tted.- Installation should comply with Australian standard AS3500.1 or relevant local authority requirements.

Failure to comply with the above may void all warranties.

Maintenance and Care-Chrome plated surfaces should be cleaned with mild liquid detergent or soap and water. -Do not use cream cleaners or citrus based cleaning products, as they are abrasive.-Use of unsuitable cleaning agents may damage the surface. Any damage caused in this way will not be covered by warranty.

Tap Operation

IN0222_revA

Milli Axon Basin Set INSTALLATION INSTRUCTIONS

NOTE : The handle with hot marking must be on the left hand side as viewed from the users position.

OFF

3/4 Turn

OFF

3/4 Turn

1 Install Outlet with Dress Plate and Sealing O-ring, position as required. Fit Nylon Washer and Black Nut and tighten securely.

Outlet

Dress PlateSealing O-ring

Basin Top

Nylon WasherBlack Nut

2 Measure centre distance between Tap Body holes in the basin top, cut Tee Piece to required length.Fit Nuts and Nylon Olives to each end of Tee Piece, connect to Tap Bodies and tighten nuts lightly.

NutNylon Olive

Tee Piece

Tap Body O-ring

Locknut2 Fit one Locknut and

Plastic Washer to each Tap Body. Plastic

Washer

Basin Top

5 mmLocknutPlastic Washer

3 Install assembly into basin top, ensure O-rings on Tee Piece are not damaged as they enter the outlet tail. Adjust Locknuts so Tap Bodies protrude 5mm above the basin top surface.

Fit remaining Plastic Washer and Locknut to each Tap Body, Tighten Nuts securely.

Tap Locknut

4 Place Dress Plates over the cartridges, fasten Tap Locknuts firmly. Fit Nylon Rings to the recesses on Tap Locknuts.

Nylon Ring

Dress Plate

4 Turn both taps to close position.Fit Tap Handles onto the cartridge spindles. Fasten Grub Screws firmly. Fit Rubber Caps to positions. G

rub Screw

Rubber C

ap

Tap Handle

INSTALLATION INSTRUCTIONS

Important Note

Mixer must be installed to the requirements of AS/NZS 3500 by a qualified plumber. Your mixer comes to you already factory assembled and tested. We do not recommend the dismantling of any internal part of the mixer. The mixers are factory tested and sealed so as to give the best performance.

page 2 of 2