microextraction of organic pollutants from liquid … richter.pdfmicroextraction of organic...

38
Microextraction of organic pollutants from liquid samples by using rotating-disk sorbent extraction Pablo Richter Departamento de Química Inorgánica y Analítica Facultad de Ciencias Químicas y Farmacéuticas Universidad de Chile

Upload: others

Post on 11-Mar-2020

18 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Microextraction of organic pollutants from liquid … Richter.pdfMicroextraction of organic pollutants from liquid samples by using rotating-disk sorbent extraction Pablo Richter Departamento

Microextraction of organic pollutants from liquid samples by using rotating-disk sorbent

extraction

Pablo Richter

Departamento de Química Inorgánica y Analítica

Facultad de Ciencias Químicas y Farmacéuticas

Universidad de Chile

Page 2: Microextraction of organic pollutants from liquid … Richter.pdfMicroextraction of organic pollutants from liquid samples by using rotating-disk sorbent extraction Pablo Richter Departamento

SAMPLE

RESULTS

SAMPLING

TRANSDUCTION OF THE

ANALYTICAL SIGNAL

DATA

TREATMENT

PREPARACIÓN

DE MUESTRA

SAMPLE

PREPARATION•QUALITY

•RAPIDITY

•COSTS

Page 3: Microextraction of organic pollutants from liquid … Richter.pdfMicroextraction of organic pollutants from liquid samples by using rotating-disk sorbent extraction Pablo Richter Departamento

Sample preparation

SOLID SAMPLES(PM10, Soil, Biosolids)

Pressurized solvent extraction

Pesticides, PAHs, PCBs, APs, APEOs, PBDEs

LIQUID SAMPLES(Waters, leachates )

Rotating disk sorbent

extraction

Page 4: Microextraction of organic pollutants from liquid … Richter.pdfMicroextraction of organic pollutants from liquid samples by using rotating-disk sorbent extraction Pablo Richter Departamento

Traditional methods of extraction in solid samples

• Organic solvent use (Green chemistry)

• Low efficiency: Lack of accuracy (quality)

• Heating: slow and no homogeneous.

• Use of open systems: higher contamination, higher

reagent use, no pressure advantages.

• High level of human participation.

Why is important the development of new extraction methods?

Page 5: Microextraction of organic pollutants from liquid … Richter.pdfMicroextraction of organic pollutants from liquid samples by using rotating-disk sorbent extraction Pablo Richter Departamento

Advances in sample extraction

• To increase the efficiency

• To increase rapidity

• To reduce (or ELIMINATE) use of

organic solvents

• Automation

• To improve quality of results

Page 6: Microextraction of organic pollutants from liquid … Richter.pdfMicroextraction of organic pollutants from liquid samples by using rotating-disk sorbent extraction Pablo Richter Departamento

TRADITIONAL

SOXHLET EXTRACTION

Solid samples

• ULTRASOUND

• MICROWAVES

• SUPERCRITICALFLUIDS

• PRESSURIZEDSOLVENT

MO

DER

N T

EC

HN

IQ

UES

Year 1879

Page 7: Microextraction of organic pollutants from liquid … Richter.pdfMicroextraction of organic pollutants from liquid samples by using rotating-disk sorbent extraction Pablo Richter Departamento

Sample preparation

Pesticides, PAHs, PCBs, APs, APEOs, PBDEs

SOLID SAMPLES(PM10, Soil, Biosolids)

Pressurized solvent extraction

LIQUID SAMPLES(Waters, leachates )

Rotating disk sorbent

extraction

Page 8: Microextraction of organic pollutants from liquid … Richter.pdfMicroextraction of organic pollutants from liquid samples by using rotating-disk sorbent extraction Pablo Richter Departamento

LIQUID-LIQUID EXTRACTION

Liquid samples

• SOLID PHASEEXTRACTION(SPE)

• SOLID PHASEMICROEXTRACTION(SPME)

• SBSE (TWISTER)

• SILICON ROD

MO

DER

N T

EC

HN

IQ

UES

Page 9: Microextraction of organic pollutants from liquid … Richter.pdfMicroextraction of organic pollutants from liquid samples by using rotating-disk sorbent extraction Pablo Richter Departamento

SPME involves the use of a fibercoated with an extracting phase,that can be a liquid or a solid,which extracts different kinds ofanalytes (including both volatileand non-volatile) from differentkinds of media, that can be inliquid or gas phase.

After extraction, the SPME fiberis transferred to the injection portof separating instruments, such asa Gas Chromatograph, wheredesorption of the analyte takesplace.

Solid phase microextraction(SPME)

(Pawliszyn, 1989)

Page 10: Microextraction of organic pollutants from liquid … Richter.pdfMicroextraction of organic pollutants from liquid samples by using rotating-disk sorbent extraction Pablo Richter Departamento

Stir bar sorptive extraction, SBSE (Twister)

Twister is a new solventless samplepreparation method for theextraction and enrichment of organiccompounds from aqueous matrices.

The method is based on the sameprinciples as solid-phasemicroextraction (SPME).

Compared with SPME (0.5 μl) , arelatively large amount of extractingphase (100 μl) is coated on a stirbar.

The technique has been appliedsuccessfully to trace analysis inenvironmental, biomedical and foodapplications.

Extremely low detection limits.

E. Baltussen, P. Sandra, F. David, C. Cramers. J. Microcolumn Separations, 11(10) 737-747 (1999)

Page 11: Microextraction of organic pollutants from liquid … Richter.pdfMicroextraction of organic pollutants from liquid samples by using rotating-disk sorbent extraction Pablo Richter Departamento

Silicon rod extraction, SRE

Silicone rod extraction (SRE) is anot commercial technology, whichemploy silicone materials in formof rods and tubes for theenrichment of organic compounds.

SRE is similar to SPME and SBSEbut with the advantage of beinginexpensive, flexible and robust.

SRE with different sizes and phasevolumes (8–635 μL) have beenapplied for the extraction of alarge variety of organicmicropollutants.

P. Popp, C. Bauer, A. Paschke and L. Montero, Anal. Chim. Acta 504 (2004), p. 307

Page 12: Microextraction of organic pollutants from liquid … Richter.pdfMicroextraction of organic pollutants from liquid samples by using rotating-disk sorbent extraction Pablo Richter Departamento

Thin-Film Microextraction

A thin sheet of polydimethylsiloxane (PDMS) membrane is employed as anextraction phase.

This PDMS extraction approach showed much higher extraction ratesbecause of the larger surface area to extraction-phase volume ratio of thethin film.

I. Bruheim, X.C. Liu and J. Pawliszyn, Anal. Chem. 75 (2003), p. 1002.

Figure 1. Drawing of the headspace membrane SPME system. 1. Deactivated stainless steel rod. 2. Flat sheet membrane. 3. Sample solution. 4. Teflon-coated stirring bar. 5. Rolled membrane. 6. Injector nut. 7. Rolled membrane. 8. Glass liner. 9. Capillary column.

Page 13: Microextraction of organic pollutants from liquid … Richter.pdfMicroextraction of organic pollutants from liquid samples by using rotating-disk sorbent extraction Pablo Richter Departamento

• Partition coefficient PDMS-water

• Analyte recovery

KO W K PDMS W C PDMS

CWm PDMS

mW

VW

VPDMS

PDM S

PDM S

W

PDM SWO

mm

m

m

mK

0

WO

WO

PDMS

K

K

m

m

10

Extraction in PDMS

Same Ko/w, recovery in SBSE is higher than in SPME

Page 14: Microextraction of organic pollutants from liquid … Richter.pdfMicroextraction of organic pollutants from liquid samples by using rotating-disk sorbent extraction Pablo Richter Departamento

Theoretical comparison between SBSE and SPME

Extraction in PDMS

0.5 µL100 µL

Page 15: Microextraction of organic pollutants from liquid … Richter.pdfMicroextraction of organic pollutants from liquid samples by using rotating-disk sorbent extraction Pablo Richter Departamento

Drawbacks observed in SBSE

Increasing stirring rate may cause physicaldamage in the extraction phase due to directcontact with the sample vial bottom.

Surface area to extraction-phase volume ratio

High cost.

Page 16: Microextraction of organic pollutants from liquid … Richter.pdfMicroextraction of organic pollutants from liquid samples by using rotating-disk sorbent extraction Pablo Richter Departamento

Rotating disk sorbent extraction (RDSE)

PDMS

Magnet

SBSE RDSE

• > Higher rotation velocity

• > A/V ratio

• < Cost

• > Automation capability

P. Richter, C. Leiva, C. Choque, A. Giordano, B. Sepúlveda, J. Chromatogr. A, 2009, 1216, 8598-8602.

Page 17: Microextraction of organic pollutants from liquid … Richter.pdfMicroextraction of organic pollutants from liquid samples by using rotating-disk sorbent extraction Pablo Richter Departamento

Sample matrix

Stagnant layer

PDMS

Extraction efficiency

Barra Magnetica

PDMS

Page 18: Microextraction of organic pollutants from liquid … Richter.pdfMicroextraction of organic pollutants from liquid samples by using rotating-disk sorbent extraction Pablo Richter Departamento

Analyte desorption:

• Solvent (methanol)

• Thermal

Batch system

Page 19: Microextraction of organic pollutants from liquid … Richter.pdfMicroextraction of organic pollutants from liquid samples by using rotating-disk sorbent extraction Pablo Richter Departamento
Page 20: Microextraction of organic pollutants from liquid … Richter.pdfMicroextraction of organic pollutants from liquid samples by using rotating-disk sorbent extraction Pablo Richter Departamento

Nonylphenol extraction from water

0 500 1000 1500 2000

0.0

0.4

0.8

1.2

Re

lative

sig

na

l

Rotation velocity, rpm

Figure 2. Rotation velocity effect on the extracted amount of NP. Extractions were made from a 250 mL water sample solution spiked with analyte at 10 µg/L. Extraction time, 20 min.

P. Richter, C. Leiva, C. Choque, A. Giordano, B. Sepúlveda, J. Chromatogr. A, 2009, 1216, 8598-8602.

Page 21: Microextraction of organic pollutants from liquid … Richter.pdfMicroextraction of organic pollutants from liquid samples by using rotating-disk sorbent extraction Pablo Richter Departamento

0 20 40 60 80 100 1200.0

0.2

0.4

0.6

0.8

1.0

Am

ount

extr

acte

d, g

Extraction time, min

Figure 3. Effect of extraction time on the extracted amount of NP. Extractions were made from a 250 mL water sample solution spiked with analyte at 10 µg/L. Rotation velocity, 1250 rpm.

Te = 20 min (RDSE)

Te = 60 min (SBSE)

Nonylphenol extraction from water

Page 22: Microextraction of organic pollutants from liquid … Richter.pdfMicroextraction of organic pollutants from liquid samples by using rotating-disk sorbent extraction Pablo Richter Departamento

Precision of the analytical response was determined by using both the same disk (n = 6) and different disks (n = 3) at a concentration of 10 µg/L, showing RSD of 3.7% and 10% for the analyte, respectively.

Page 23: Microextraction of organic pollutants from liquid … Richter.pdfMicroextraction of organic pollutants from liquid samples by using rotating-disk sorbent extraction Pablo Richter Departamento
Page 24: Microextraction of organic pollutants from liquid … Richter.pdfMicroextraction of organic pollutants from liquid samples by using rotating-disk sorbent extraction Pablo Richter Departamento

PESTICIDE log Ko/w

Pirimicarb 1,7

Dichlorvos 1,9

Malathion 2,75

Diazinon 3,86

Tebuconazole 3,89

Lindane 4,25

Chlorpyrifos 5,27

Cypermethrin 6,38

Fenvalerate 6,76

Cyhalothrin 6,85

Extraction of pesticides from water

Page 25: Microextraction of organic pollutants from liquid … Richter.pdfMicroextraction of organic pollutants from liquid samples by using rotating-disk sorbent extraction Pablo Richter Departamento

0

20

40

60

80

100

120

Dichlorvos Fenvalerate

Recovery

, %

30 min 1 h 2 h 3 h 24 h

log Ko/w = 1,9 log Ko/w = 6,8

Extraction of Pesticides from water

Page 26: Microextraction of organic pollutants from liquid … Richter.pdfMicroextraction of organic pollutants from liquid samples by using rotating-disk sorbent extraction Pablo Richter Departamento

Extraction of organochlorinepesticides and PCBs from water

Page 27: Microextraction of organic pollutants from liquid … Richter.pdfMicroextraction of organic pollutants from liquid samples by using rotating-disk sorbent extraction Pablo Richter Departamento

Extraction of organochlorinepesticides

0 50 100 150 200 250 300

0,0

0,5

1,0

1,5

2,0

2,5

HCB

lin

ald

Ra

n d

e á

rea

tiempo (min)

0 20 40 60 80 100

0,0

0,1

0,2

0,3

0,4

0,5

0,6

HCB

lin

ald

zo

n d

e á

rea

tiempo (min)

SAMPLE VOLUME: 50 ml SAMPLE VOLUME: 10 ml

Page 28: Microextraction of organic pollutants from liquid … Richter.pdfMicroextraction of organic pollutants from liquid samples by using rotating-disk sorbent extraction Pablo Richter Departamento

Extraction of organochlorine pesticides: Effect of the sample volume

0,0

0,2

0,4

0,6

0,8

1,0

HCB Lindano Aldrin

Rel

ativ

e re

spo

nse

Relative response (30min)

50mL 30mL 10mL

Page 29: Microextraction of organic pollutants from liquid … Richter.pdfMicroextraction of organic pollutants from liquid samples by using rotating-disk sorbent extraction Pablo Richter Departamento

Pre-concentration of chromogenic organiccompounds and direct determination by solid

phase spectrophotometry (RDSE)

P. Richter, A. Cañas, C. Muñoz, C. Leiva. Anal. Chim. Acta, 2011, in press.

Ex:

• MALACHITE GREEN• CRYSTAL VIOLET

Page 30: Microextraction of organic pollutants from liquid … Richter.pdfMicroextraction of organic pollutants from liquid samples by using rotating-disk sorbent extraction Pablo Richter Departamento

Extraction of chromogenic organic compounds (RDSE)

OH

Page 31: Microextraction of organic pollutants from liquid … Richter.pdfMicroextraction of organic pollutants from liquid samples by using rotating-disk sorbent extraction Pablo Richter Departamento

Extraction of chromogenic organic compounds

Figure 1. Photograph of the Teflon rotating disk containing the PDMS phase. (A) Before and

(B) after extraction of a 100 mL water sample containing 40 µg L-1 MG.

Page 32: Microextraction of organic pollutants from liquid … Richter.pdfMicroextraction of organic pollutants from liquid samples by using rotating-disk sorbent extraction Pablo Richter Departamento

Figure 2. Absorption spectra of MG in (A) aqueous solution at a concentration of 2 mg L-1, using a typical 1 cm cell, and in (B) PDMS disk

phase after concentration from a solution of 0.2 mg L-1, using a path length of 0.1 cm (phase thickness).

A

Extraction of chromogenic organic compounds

Page 33: Microextraction of organic pollutants from liquid … Richter.pdfMicroextraction of organic pollutants from liquid samples by using rotating-disk sorbent extraction Pablo Richter Departamento

Figure 4. Effect of the extraction time on the absorbance in

PDMS disk phase. MG was concentrated at 1000 rpm from

100 mL of aqueous solutions containing 0.5 mg L-1 MG and

10% sodium sulfate at 75ºC.

Figure 5. Effect of the rotation velocity of the disk on

the absorbance. MG was concentrated for 18 min from

100 mL of aqueous solutions containing 0.5 mg L-1 MG

and 10% sodium sulfate at 75ºC.

Extraction of chromogenic organic compounds

Page 34: Microextraction of organic pollutants from liquid … Richter.pdfMicroextraction of organic pollutants from liquid samples by using rotating-disk sorbent extraction Pablo Richter Departamento

A

Figure 6. Effect of pH on the absorbance in PDMS disk phase. MG was

concentrated for 18 min at 1000 rpm from 100 mL of aqueous solutions containing

0.5 mg L-1 MG and 10% sodium sulfate at 75ºC.

Extraction of chromogenic organic compounds

Page 35: Microextraction of organic pollutants from liquid … Richter.pdfMicroextraction of organic pollutants from liquid samples by using rotating-disk sorbent extraction Pablo Richter Departamento

Conclusions The extraction capability of a rotating disk containing a PDMS film has been

demonstrated. In this method, the disk, with a large surface area, can be

stirred at higher velocity than the stir bar used in SBSE, without damaging

the phase because it does not contact the sample vial bottom; thus, analyte

mass transfer to the PDMS surface is facilitated.

PDMS phase on the disk could be used for at least 50 experiments. In any

case, replacement of the PDMS film on the disk is very easy and inexpensive,

as compared to the stir bar used in SBSE.

Another possible variant of the present RDSE technique is to use another

solid phase instead of the PDMS film to extract more polar analytes.

The extraction capability of chromogenic compounds from water samples on

a rotating disk containing a PDMS film has been demonstrated. After

extraction, the PDMS phase was used directly in the solid phase

spectrophotometric determination of the analyte.

PDMS phases on the disk could be reused after desorption of MG. After a

batch of 50 determinations, all phases were cleaned simultaneously for 1 h

by desorption of MG with methanol. Additionally, replacement of the PDMS

film on the disk is simple and low cost.

Page 36: Microextraction of organic pollutants from liquid … Richter.pdfMicroextraction of organic pollutants from liquid samples by using rotating-disk sorbent extraction Pablo Richter Departamento

Agradecimientos

• Muchas gracias a ustedes por la atención

• Financiamiento: Proyectos FONDECYTRegulares y Proyectos CONICYT dedoctorado.

• Integrantes del Laboratorio de QuímicaAnalítica y Ambiental

Page 37: Microextraction of organic pollutants from liquid … Richter.pdfMicroextraction of organic pollutants from liquid samples by using rotating-disk sorbent extraction Pablo Richter Departamento

Agradecimientos

Page 38: Microextraction of organic pollutants from liquid … Richter.pdfMicroextraction of organic pollutants from liquid samples by using rotating-disk sorbent extraction Pablo Richter Departamento

CELDA DE EXTRACCIÓN