Result and Analysis of Micro Vickers Hardness Test
Department of Metallurgical and Materials Engineering
INDIAN INSTITUTE OF TECHNOLOGY KHARAGPUR
• It is used to determine hardness over very small areas.• Hardness of different phases can be
measured using this test.• Indenter is the same as used in the
Vickers Hardness Test.• The load applied in Micro Vickers test is
much smaller compared to the load in the Vickers Test (1 – 1000 gf).
Results of Micro Vickers Test
Load = 50 gf, Dwell Time = 15 sec
Diagonal 1 Diagonal 2 Hardness
17.48 20.35 259.1
21.5 21.96 196.3
21.89 19.57 215.8
21.13 22.05 199
• The main drawback of the Micro Vickers test is the need to optically measure the indent size.
• This requires that the test point be highly polished to be able to see the indent well enough to make an accurate measurement.
(a)Perfect Indentation(b)Pincushion indentation due to sinking
in (Overestimation of diagonal length)(c)Barreled Indentation due to ridging
(Underestimation of diagonal length)