micro downlight with trim - mdf - usai lighting

14
Micro Downlight with Trim - MDF Color Rendering Index Source Lumens: White Bevel Performance Lumens Per Watt: Delivered Lumens: Black Bevel Performance Lumens Per Watt: Delivered Lumens: Color Consistency: 2-Step MacAdam Ellipse Performance data based on 3000K, 50 o optic. DELIVERED PERFORMANCE: 80+ 90+ 750 625 68 57 500 425 56 47 400 350 MDF02 2 CELL 8W Color Rendering Index: Multiplier for Lumen Output: CORRELATED COLOR TEMPERATURE 80+ 90+ 0.93 0.79 2700K 80+ 90+ 1.00 0.84 3500K 80+ 90+ 1.00 0.84 3000K 80+ 90+ 1.07 0.93 4000K MICRO DOWNLIGHT PERFORMANCE DATA T 845–565–8500 F 845–561–1130 1126 River Road New Windsor, NY 12553 © 2016. USAI, LLC. All rights reserved. All designs protected by copyright. Patents pending. USAI, BeveLED and Classic White are registered trademarks of USAI, LLC Revised 07/07/2020 usailighting.com [email protected] Meet Micro™our smallest LED downlight which artistically blends technology and sleek design. Micro provides a unique aesthetic for downlights, with a new linear form factor and jewel-like presence in the ceiling plane. Ceilings are powerful yet whisper quiet with Micro’s minimal aperture size of just 1.25”. Available as a downlight in 2, 4, 6, 8 and 12 cell configurations, Micro brings elegance and clean style to lobbies, corporate headquarters, hotels and residential applications. FEATURES Micro downlights offer a new form factor for a modern and innovative downlight aesthetic Overlap flange trims are compatible with sheetrock, ACT, wood/millwork, and many other ceiling materials Industry leading illumination and craftsmanship New construction and remote driver housing options for easy installation in any site condition Page 1 80+ 90+ 1475 1250 76 64 1000 825 62 52 825 700 MDF04 4 CELL 13W 80+ 90+ 2200 1850 72 61 1475 1250 60 50 1225 1025 MDF06 6 CELL 21W 80+ 90+ 2900 2425 72 61 1925 1625 60 50 1600 1350 MDF08 8 CELL 27W 80+ 90+ 4675 3925 76 64 3125 2625 63 53 2575 2175 MDF12 12 CELL 41W MDF02 MDF04 MDF06 MDF12 MDF08 Classic White Classic White

Upload: others

Post on 16-Oct-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Micro Downlight with Trim - MDF - USAI Lighting

Micro™ Downlight with Trim - MDF

Color Render ing Index

Source Lumens:

White Bevel Performance

Lumens Per Wat t :

De l ive red Lumens:

Black Bevel Performance

Lumens Per Wat t :

De l ive red Lumens:

Co lor Consis t ency: 2- S tep MacAdam El l ipse

Pe r fo rmance da ta based on 3000K, 50 o op t ic .

DELIVERED PERFORMANCE:

80+ 90+

750 625

68 57

500 425

56 47

400 350

MDF022 CELL

8W

Color Render ing Index:

Mult iplier for Lumen Output:

CORRELATED COLOR TEMPERATURE

80+ 90+

0.93 0.79

2700K

80+ 90+

1.00 0.84

3500K

80+ 90+

1.00 0.84

3000K

80+ 90+

1.07 0.93

4000K

MICRO DOWNLIGHT PERFORMANCE DATA

T 845–565–8500F 845–561–1130

1126 River RoadNew Windsor, NY 12553

© 2016. USAI, LLC. All rights reserved. All designs protected by copyright.

Patents pending. USAI, BeveLED and Classic White are registered trademarks of USAI, LLC

Revised 07/07/2020

[email protected]

Meet Micro™— our smallest LED downlight which artistically blends technology and sleek design. Micro provides a unique aesthetic for downlights, with

a new linear form factor and jewel-like presence in the ceiling plane. Ceilings are powerful yet whisper quiet with Micro’s minimal aperture size of just

1.25”. Available as a downlight in 2, 4, 6, 8 and 12 cell confi gurations, Micro brings elegance and clean style to lobbies, corporate headquarters, hotels and

residential applications.

FEATURES

• Micro downlights offer a new form factor for a modern and innovative downlight aesthetic

• Overlap fl ange trims are compatible with sheetrock, ACT, wood/millwork, and many other ceiling materials

• Industry leading illumination and craftsmanship

• New construction and remote driver housing options for easy installation in any site condition

Page 1

80+ 90+

1475 1250

76 64

1000 825

62 52

825 700

MDF044 CELL13W

80+ 90+

2200 1850

72 61

1475 1250

60 50

1225 1025

MDF06 6 CELL21W

80+ 90+

2900 2425

72 61

1925 1625

60 50

1600 1350

MDF088 CELL27W

80+ 90+

4675 3925

76 64

3125 2625

63 53

2575 2175

MDF1212 CELL

41W

MDF02 MDF04 MDF06

MDF12MDF08

Classic White

Classic White

Page 2: Micro Downlight with Trim - MDF - USAI Lighting

TRIM DETAILS

T 845–565–8500F 845–561–1130

1126 River RoadNew Windsor, NY 12553

© 2016. USAI, LLC. All rights reserved. All designs protected by copyright.

Patents pending. USAI, BeveLED and Classic White are registered trademarks of USAI, LLC

Revised 07/07/2020

[email protected]

Micro™ Downlight with Trim - MDF

15”

MDF022 CELL

10”

7-1/2”

5”

2-1/2”

5/8”

5/8”

5/8”

5/8”

5/8”

8-1/4”

3-1/4”

5-3/4”

10-3/4”

15-3/4”

1-1/4”

2”

1-1/4”

2”

1-1/4”

2”

1-1/4”

2”

1-1/4”

2”

Flange Finish

Lens

Bevel Finish

MDF044 CELL

MDF066 CELL

MDF088 CELL

MDF1212 CELL

Page 2

Available Housing Options:

Micro Downlight with Integral Driver Housing - Page 3

Micro Downlight with Remote Driver Housing - Page 5

Page 3: Micro Downlight with Trim - MDF - USAI Lighting

CEILING CUTOUT MDF04: 1-11/16” x 5-7/16”MDF06: 1-11/16” x 7-15/16”MDF08: 1-11/16” x 10-7/16”MDF12: 1-11/16” x 15-7/16”

LISTINGS Dry/Damp/Wet location listed for white (WH) and black (BL) bevel fi nishes only. All other bevel fi nishes are Dry/Damp location listed. NRTL/CSA-US tested to UL standards.IBEW union made.

NOTES• Not for use in corrosive environment• Use of pressure washer voids warranty• Ambient temperatures at fi xture location should not exceed 40°C during normal operation.

PHOTOMETRICS Consult factory or website for IES fi les. Tested in accordance with IESNA LM79.

HOW TO SPECIFY

Micro™ Downlight with Integral Driver Housing - MDF

T 845–565–8500F 845–561–1130

1126 River RoadNew Windsor, NY 12553

© 2016. USAI, LLC. All rights reserved. All designs protected by copyright.

Patents pending. USAI, BeveLED and Classic White are registered trademarks of USAI, LLC

Revised 07/07/2020

[email protected]

MicroDownlight

MDFMicroDownlightWithOverlapFlangeTrim

Size / WattageOptions

Remote onlySee page 5

13H113W LED

21H121W LED

27H127W LED

41H141W LED

LED ColorTemperatureOptions

27KS2700K, 80+ CRI

27KH2700K, 90+ CRI

30KS 3000K, 80+ CRI

30KH3000K, 90+ CRI

35KS 3500K, 80+ CRI

35KH3500K, 90+ CRI

40KS 4000K, 80+ CRI

40KH4000K, 90+ CRI

2-Step MacAdamEllipse Color

BeamOptions

3535° Beam

5050° Beam

VoltageOptions

UNV120V-277V

120V

Accessories(Optional)

CB2727” C-ChannelBars

CB5252” C-ChannelBars

NOTE:Emergency battery not available with Integral driver housing – remoteonly – see page 5

Dimming Driver Options

For use with UniversalVoltage 120V - 277V

D2 0-10V dim, 10% (provided standard)

D4H Lutron H ECO, 1% Fade (1)

D6E EldoLED 0-10V, 1%, (1)

D6F EldoLED 0-10V, 1% (1)

D7E EldoLED DALI, 1% (1)

For use with 120V only

D3 Lutron Hi-Lume 1%2-wire, 120V only (1)

D19 Phase dimming 1%,120V only

1 Not available with MDF04NC housing - remote only - see page 5

MDF__ __

FAMILY LED COLOR CHOICES FIXTURE

NC

MountingOptions

NCNew Construction Housing,IntegralDriver

Flange FinishOptions

WH White Flange

BLBlack Flange

Numberof Cells

022 Cell

044 Cell

066 Cell

088 Cell

1212 Cell

Page 3

INTEGRAL DRIVER HOUSING

Please note that MDF02 (8W) is not available with Integral driver housing - see page 5

FIELD REPLACEABLE LED LIGHT ENGINEis serviceable through the aperture with a Philips screwdriver. All USAI Lighting Classic White light engines feature industry-leading color consistency within a 2-Step MacAdam Ellipse.

FIELD REPLACEABLE DRIVER 0-10V, 100%-10% solid state electronic constant current D2 dimming driver with a high power factor provided standard and sources 2mA (MDF12 sources 4mA). Note 12 cell requires two drivers for each type. Driver complies with IEEEC62.41 surge protection and is serviceable from above or below the ceiling. Other dimming drivers optionally available.

FIXTURE WEIGHT Weights do not include optional channel bar mounting hardware. NC Integral driver housing with trim:

MDF04 MDF06 MDF08 MDF12 7LB 9LBS 9LBS 14.5LBS

HOUSING, INTEGRAL DRIVERMicro new construction housing is fabricated of 18 and 20 gauge steel with black fi nish. Thru wire junction box with 6-10 knockouts features a slide mechanism that allows for easy below-ceiling access for service. MDF04 NC housing accepts D2 and D19 drivers only.

MOUNTINGMicro fi xtures that are provided with an overlap fl ange are designed for use in sheetrock, acoustical ceiling tile, wood/millwork, and many other ceiling materials up to 1” thick maximum. Butterfl y brackets and adjustable nailer bars extendible from 14” to 24” centers with integral nails are provided for attachment to building structure. Butterfl y brackets can be relocated in the fi eld to adjacent sides of housing. C-channel bars are optionally available for acoustical ceiling applications.

WARRANTYBased on IESNA LM80-2008, Micro has a 50,000 hour rated life at 70% lumen maintenance (L70). USAI Lighting Warranty covers replacement parts for 5 years from date of shipment.

INTEGRAL DRIVER SPECIFICATIONS

Bevel FinishOptions

WH WhiteMatte

BLBlack Matte

BG Black Specular

SMSilver Matte

SG Silver Specular

BZBronze Specular

RGRose Gold Specular

Classic White

Page 4: Micro Downlight with Trim - MDF - USAI Lighting

T 845–565–8500F 845–561–1130

© 2016. USAI, LLC. All rights reserved. All designs protected by copyright.

Patents pending. USAI, BeveLED and Classic White are registered trademarks of USAI, LLC

Revised 07/07/2020

[email protected]

Micro™ Downlight with Integral Driver Housing - MDF

113⁄16"125⁄8"

51⁄8"

161⁄4"

125⁄8"

MDF06 = 1115⁄16”

MDF08 = 1115⁄16”

MDF12 = 1615⁄16”

41⁄2"

MDF06MDF08MDF12

MDF04

1" Max. Ceiling Thickness

NEW CONSTRUCTION HOUSING - NC

Page 4

1126 River RoadNew Windsor, NY 12553

MDF04 = 615⁄16”

NOTE: MDF04 NC housing accepts D2 and D19 dimming drivers only.

1” Max. Ceiling Thickness

Note: Integral housing butterfl y

brackets are fi eld adjustable

for 1-5/16” of vertical

travel and can be relocated to

adjacent sides in the fi eld

Note: Integral housing butterfl y

brackets are fi eld adjustable

for 1-5/16” of vertical

travel and can be relocated to

adjacent sides in

the fi eld

USAI patent pending slide mechanism provides easy access to internal components for service and maintenance.

Junction Box Service PositionInstalled Position / Light Engine Service Driver service position

3⁄8” Typ.

113⁄16"

113⁄16"113⁄16"

3⁄8” Typ.

315⁄16"

315⁄16"

Page 5: Micro Downlight with Trim - MDF - USAI Lighting

HOW TO SPECIFY

Micro™ Downlight with Remote Driver Housing - MDF

T 845–565–8500F 845–561–1130

1126 River RoadNew Windsor, NY 12553

© 2016. USAI, LLC. All rights reserved. All designs protected by copyright.

Patents pending. USAI, BeveLED and Classic White are registered trademarks of USAI, LLC

Revised 07/07/2020

[email protected]

MicroDownlight

MDFMicroDownlightWithOverlapFlangeTrim

Size / WattageOptions

08H18W LED

13H113W LED

21H121W LED

27H127W LED

41H141W LED

LED ColorTemperatureOptions

27KS2700K, 80+ CRI

27KH2700K, 90+ CRI

30KS 3000K, 80+ CRI

30KH3000K, 90+ CRI

35KS 3500K, 80+ CRI

35KH3500K, 90+ CRI

40KS 4000K, 80+ CRI

40KH4000K, 90+ CRI

2-Step MacAdamEllipse Color Consistency is standard for all

BeamOptions

3535° Beam

5050° Beam

Accessories(Optional)

CB2727” C-ChannelBars

CB5252” C-ChannelBars

MDF__ __

FAMILY LED COLOR CHOICES FIXTURE

RM

MountingOptions

RMRemote Driver Housing

Flange FinishOptions

WH White Flange

BLBlack Flange

Bevel FinishOptions

WH WhiteMatte

BLBlack Matte

BG Black Specular

SMSilver Matte

SG Silver Specular

BZBronze Specular

RGRose Gold Specular

Numberof Cells

022 Cell

044 Cell

066 Cell

088 Cell

1212 Cell

Page 5

REMOTE DRIVER

2. Specify Remote Power SupplySpecify remote power supply part number in table below

1. Specify fi xture part number and options.

120V

RPAMicroRemote Power Supply

EM7Emergency Batteryprovides emergency power to one fi xture perpower supply andrequires remote enclosure (by others) with a minimum size of14.5” L x 6.5” W x 3” H.Emergency battery is not available with 2 cellMDF02-08H1 LED

RPA

D2 0-10V dim, 10% D4H Lutron H ECO, 1% Fade (1) D6E EldoLED 0-10V, 1% D6F EldoLED 0-10V, 1%

D3 Lutron 2-wire, 1% D19 Phase 2-wire, 1% (1)1 Not available with LED 08H1

08H1 2 Cell 8W LED13H1 4 Cell 13W LED21H1 6 Cell 21W LED27H1 8 Cell 27W LED41H1 12 Cell 41W LED

08H1 2 Cell 8W LED

08 Fixtures Max

03 Fixtures Max02 Fixtures Max

02 Fixtures

01 Fixture

SINGLE CHANNEL REMOTE POWER SUPPLIES

D6E EldoLED 0-10V, 1% D6F EldoLED 0-10V, 1% D7E EldoLED DALI, 1% D8E EldoLED DMX, 1%

MULTI CHANNEL REMOTE POWER SUPPLIES

TypeCode

Remote EmergencyOption

Remote Dimming Driver Typeand Dim Level

VoltageFixture Size andWattage Options

Fixture Quantity per Remote Power Supply

04 Fixtures Max UNV120V - 277V

UNV120V - 277V

USAI

Power

Supply

Must Be

Specifi ed

08H1 2 Cell 8W LED13H1 4 Cell 13W LED21H1 6 Cell 21W LED27H1 8 Cell 27W LED41H1 12 Cell 41W LED*

*Note 12 cell requires two drivers for D2, D3, D4E and D19 driver types.

Classic White

Page 6: Micro Downlight with Trim - MDF - USAI Lighting

CEILING CUTOUT MDF02: 1-11/16” x 2-15/16”MDF04: 1-11/16” x 5-7/16”MDF06: 1-11/16” x 7-15/16”MDF08: 1-11/16” x 10-7/16”MDF12: 1-11/16” x 15-7/16”

LISTINGS Dry/Damp/Wet location listed for white (WH) and black (BL) bevel fi nishes only. All other bevel fi nishes are Dry/Damp location listed. NRTL/CSA-US tested to UL standards.IBEW union made.

NOTES• Not for use in corrosive environment• Use of pressure washer voids warranty• Ambient temperatures at fi xture location should not exceed 40°C during normal operation.

PHOTOMETRICS Consult factory or website for IES fi les. Tested in accordance with IESNA LM79.

HOW TO SPECIFY

Micro™ Downlight with Remote Driver Housing - MDF

T 845–565–8500F 845–561–1130

1126 River RoadNew Windsor, NY 12553

© 2016. USAI, LLC. All rights reserved. All designs protected by copyright.

Patents pending. USAI, BeveLED and Classic White are registered trademarks of USAI, LLC

Revised 07/07/2020

[email protected]

Page 6

FIELD REPLACEABLE LED LIGHT ENGINEis serviceable through the aperture with a Philips screwdriver. All USAI Lighting Classic White light engines feature industry-leading color consistency within a 2-Step MacAdam Ellipse..

FIXTURE WEIGHT Weights do not include optional channel bar mounting hardware or remote drivers. RM Remote driver tray with trim weights:

MDF02 MDF04 MDF06 MDF08 MDF12 1LB 2LBS 2.5LBS 3LBS 3.5LBS

REMOTE DRIVER HOUSINGNew construction tray is fabricated of 20 ga. steel construction and is supplied with quick connects for use with remotely located driver. Driver is provided separately for remote location on site, enclosure to be provided by others.

REMOTE LOCATION DRIVER All remote dimming driver options must be clearly specifi ed in the “RP” table. Remote power supplies require enclosures by others that meet local codes and must be located in an accessible service panel within 100ft of the light fi xture; see remote driver details for coordination of enclosure sizes. All dimming drivers comply with IEEE C62.41 surge protection.

REMOTE LOCATION EMERGENCY Remote emergency battery IOTA ILB-CP07 provides 200mA to one fi xture for 90 minutes. When used with multichannel power supplies, emergency battery supplies power to 1 fi xture only through channel 1. Remote power supplies with EM option require an enclosure with minimum size of 14.5”L x 6.5”W x 3”H by others that meets local codes. Battery is not available with 08H1 LED.

MOUNTINGMicro fi xtures that are provided with an overlap fl ange are designed for use in sheetrock, acoustical ceiling tile, wood/millwork, and many other ceiling materials up to 1” thick maximum. Butterfl y brackets and adjustable nailer bars extendible from 14” to 24” centers with integral nails are provided for attachment to building structure. Butterfl y brackets can be relocated in the fi eld to adjacent sides of housing. C-channel bars are optionally available for acoustical ceiling applications.

WARRANTYBased on IESNA LM80-2008, Micro has a 50,000 hour rated life at 70% lumen maintenance (L70). USAI Lighting Warranty covers replacement parts for 5 years from date of shipment. Warranty is void if Micro is used with any power supply other than that which is provided by USAI.

REMOTE DRIVER HOUSING SPECIFICATIONS

Remote Power Supply Dimming Option Wire Gauge Required* (by others) UNV-D6E EldoLED 0-10V, 1% UNV-D6F EldoLED 0-10V, 1% UNV-D7E EldoLED DALI, 1% UNV-D8E EldoLED DMX, 1%

If you want to connect 8 fi xtures maximum per power supply select from the following options:

RPRP2REMOTEREMOTEPOWEPOWERSUPPLYSUPPLY

-

A

+

INPUT WIREINPUT WIRES

-+

USE FOR WIRING FIXTURESUSE FOR WIRING FIXTURESMDF0MDF02M2M DP02DP02MDF0MDF04M4M DP04DP04MDF0MDF06M6M DP06DP06MDF0MDF08M8M DP08DP08

FIXTURFIXTURE

SEE DIMMING COMPSEE DIMMING COMPATIBILITATIBILITYSHEET FOR SHEET FOR DETAILDETAILS

SEE DIMMING COMPSEE DIMMING COMPATIBILITATIBILITYSHEET FOR SHEET FOR DETAILDETAILS

B

USE ONLY FOR WIRING FIXTURESUSE ONLY FOR WIRING FIXTURESMDF0MDF02MDP0MDP02(2) FIXTURES IN SERIES(2) FIXTURES IN SERIES

INPUT WIREINPUT WIRES

FIXTURE FIXTURE 1

+

RPRP2REMOTEREMOTEPOWEPOWERSUPPLYSUPPLY

-+

- FIXTURE FIXTURE 2

-+

If you want to connect 1-2 fi xtures maximum per power supply select from the following options:

Remote Power Supply Dimming Option Wire Gauge Required* (by others) UNV-D2 0-10V dim, 10% 14/12 5.75” W x 2.625” L x 2” H UNV-D6E EldoLED 0-10V, 1% UNV-D6F EldoLED 0-10V, 1% 120V-D3 Lutron 2-wire phase, 1% 14/12 6.25” W x 4” L x 2” H

* Wire gauge 14/12 = Maximum distance from light fi xture to remote power supply is 100’ using 12 gauge wire, 50’ using 14 gauge wire. * Wire gauge 18/16 = Maximum distance from light fi xture to remote power supply is 100’ using 16 gauge wire, 50’ using 18 gauge wire.

SEE DIMMINGCOMPATIBILTY

SHEETS FOR DETAILS

SEE DIMMINGCOMPATIBILTY

SHEETS FOR DETAILS

HOMERUN SERIES

2-Cell Micro Remote Power Supply Requirements and Wiring Diagrams2-Cell can be wired in homeruns (wiring diagram A) or in series pairs (wiring diagram B).

18/16 10.375” W x 4” L x 2” H

18/16 6.25” W x 4” L x 2” H

Requirements and Wiring Diagrams forMDF02 MWF02MDL02 MWL02MDM02 MWM02

RPA-08-08H1

RPA-01-08H1RPA-02-08H1

RPAREMOTEPOWERSUPPLY

RPAREMOTEPOWERSUPPLY

Minimum Enclosure Size Required

Minimum Enclosure Size Required

Page 7: Micro Downlight with Trim - MDF - USAI Lighting

HOW TO SPECIFY

Micro™ Downlight with Remote Driver Housing - MDF

T 845–565–8500F 845–561–1130

1126 River RoadNew Windsor, NY 12553

© 2016. USAI, LLC. All rights reserved. All designs protected by copyright.

Patents pending. USAI, BeveLED and Classic White are registered trademarks of USAI, LLC

Revised 07/07/2020

[email protected]

Page 7

If you want to connect 3-4 fi xtures maximum per power supply select from the following options:

RPRP2REMOTEREMOTEPOWEPOWERSUPPLYSUPPLY

-

A

+

INPUT WIREINPUT WIRES

-+

USE FOR WIRING FIXTURESUSE FOR WIRING FIXTURESMDF0MDF02M2M DP02DP02MDF0MDF04M4M DP04DP04MDF0MDF06M6M DP06DP06MDF0MDF08M8M DP08DP08

FIXTURFIXTURE

SEE DIMMING COMPSEE DIMMING COMPATIBILITATIBILITYSHEET FOR SHEET FOR DETAILDETAILSSEE DIMMING

COMPATIBILTY SHEETS

FOR DETAILS

If you want to connect 2 fi xtures maximum per power supply select from the following options:

-

CSEE SEE DIDIMMING COMMING COMPATMPATIBIBILITILITY

SHSHEEEET T FOFOR R DEDETATAILILS

++++

+

USE ONLY FOR WIRING FIXTURESUSE ONLY FOR WIRING FIXTURESMDF1MDF12MDP12 MDP12 EACH FIXTURE REQUIRES (2) RUNEACH FIXTURE REQUIRES (2) RUNS

-

FIFIXTURXTURE

-

-

RPRP2REMOTEREMOTEPOWEPOWERSUPPLYSUPPLY

+

INPUT WIREINPUT WIRESSEE DIMMINGCOMPATIBILTY

SHEETS FOR DETAILS

4, 6, and 8-Cell Micro Remote Power Supply Requirements and Wiring DiagramsMust be wired in homeruns per wiring diagram “A” below.

HOMERUN

12-Cell Micro Remote Power Supply Requirements and Wiring Diagrams*Must be wired with 2 homeruns per fi xtures as shown in wiring diagram “C” below.*Note 12 cell requires two drivers for D2, D3, D4E and D19 driver types.

2X HOMERUN

Requirements and Wiring Diagrams for MDF04 MWF04 MAF04MDF06 MWF06 MAF06MDF08 MWF08 MAF08MDL04 MWL04 MAL04MDL06 MWL06 MAL06MDL08 MWL08 MAL08MDM04 MWM04 MAM04MDM06 MWM06 MAM06MDM08 MWM08 MAM08

Requirements and Wiring Diagrams for MDF12 MWF12 MAF12MDL12 MWL12 MAL12MDM12 MWM12 MAM12

RPAREMOTEPOWERSUPPLY

RPA-02-41H1

RPAREMOTEPOWERSUPPLY

Remote Power Supply Dimming Option Wire Gauge Required* RP Only RP with EM Option** UNV-D6E EldoLED 0-10V, 1% UNV-D6F EldoLED 0-10V, 1% UNV-D7E EldoLED DALI, 1% UNV-D8E EldoLED DMX, 1%

18/16 10.375” W x 4” L x 2” H 14.5" W x 6.5" L x 3" H

Minimum Enclosure Size Required (by others)

RPA-04-13H1RPA-04-21H1RPA-03-27H1

Remote Power Supply Dimming Option Wire Gauge Required* RP Only RP with EM Option** UNV-D6E EldoLED 0-10V, 1% UNV-D6F EldoLED 0-10V, 1% UNV-D7E EldoLED DALI, 1% UNV-D8E EldoLED DMX, 1%

18/16 10.375” W x 4” L x 2” H 14.5" W x 6.5" L x 3" H

Minimum Enclosure Size Required (by others)

If you want to connect 1 fi xture maximum per power supply select from the following options:

* Wire gauge 14/12 = Maximum distance from light fi xture to remote power supply is 100’ using 12 gauge wire, 50’ using 14 gauge wire. * Wire gauge 18/16 = Maximum distance from light fi xture to remote power supply is 100’ using 16 gauge wire, 50’ using 18 gauge wire. ** Emergency battery remote power supplies cannot be located any more than 50 feet from light fi xture.

Remote Power Supply Dimming Option Wire Gauge Required* RP Only RP with EM Option** UNV-D2 0-10V dim, 10% 14/12 8” W x 6.75” L x 2” H UNV-D4H Lutron H ECO, 1% Fade 14/12 8” W x 6.75” L x 2” H UNV-D6E EldoLED 0-10V, 1% UNV-D6F EldoLED 0-10V, 1% 120V-D3 Lutron 2-wire phase, 1% 14/12 8” W x 6.75” L x 2” H 120V-D19 Hatch 2-wire phase, 1% 14/12 7.25” W x 4” L x 2” H

18/16 8” W x 6.75” L x 2” H 14.5" W x 6.5" L x 3" H

Minimum Enclosure Size Required (by others)

RPA-01-41H1

If you want to connect 1 fi xture maximum per power supply select from the following options:

* Wire gauge 14/12 = Maximum distance from light fi xture to remote power supply is 100’ using 12 gauge wire, 50’ using 14 gauge wire. * Wire gauge 18/16 = Maximum distance from light fi xture to remote power supply is 100’ using 16 gauge wire, 50’ using 18 gauge wire. ** Emergency battery remote power supplies cannot be located any more than 50 feet from light fi xture.

Remote Power Supply Dimming Option Wire Gauge Required* RP Only RP with EM Option** UNV-D2 0-10V dim, 10% 14/12 7” W x 2.625” L x 2” H UNV-D4H Lutron H ECO, 1% Fade 14/12 6.25” W x 4” L x 2” H UNV-D6E EldoLED 0-10V, 1% UNV-D6F EldoLED 0-10V, 1% 120V-D3 Lutron 2-wire phase, 1% 14/12 6.25” W x 4” L x 2” H 120V-D19 Hatch 2-wire phase, 1% 14/12 5.75” W X 2.625” L X 2” H

18/16 6.25” W x 4” L x 2” H 14.5" W x.5" L x 3" H

Minimum Enclosure Size Required (by others)

RPA-01-13H1RPA-01-21H1RPA-01-27H1

Page 8: Micro Downlight with Trim - MDF - USAI Lighting

T 845–565–8500F 845–561–1130

© 2016. USAI, LLC. All rights reserved. All designs protected by copyright.

Patents pending. USAI, BeveLED and Classic White are registered trademarks of USAI, LLC

Revised 07/07/2020

[email protected]

Micro™ Downlight with Remote Driver Housing - MDF

Page 8

1126 River RoadNew Windsor, NY 12553

REMOTE DRIVER HOUSING - RM

MDF04 = 615⁄16”MDF06 = 97⁄16”MDF08 = 1115⁄16”MDF12 = 1615⁄16”

1" Max. Ceiling Thickness

31⁄4”

MDF04 = 413⁄16”MDF06 = 69⁄16”MDF08 = 73⁄4”MDF12 = 813⁄16”

113⁄16” 113⁄16”

Note: Remote housing butterfl y

brackets are fi eld adjustable

1-5/16” of vertical travel

and can be relocated to

adjacent sides in the fi eld.

3⁄8” Typ.

113⁄16"43⁄4"

21⁄2"

MDF02

1” Max. Ceiling Thickness

MDF02 = 45⁄8”

Note: Integral housing butterfl y

brackets are fi eld adjustable

for 1-5/16” of vertical

travel and can be relocated to

adjacent sides in the fi eld

3⁄8” Typ.

113⁄16"

MDF04MDF06MDF08MDF12

Page 9: Micro Downlight with Trim - MDF - USAI Lighting

V+ RED

V- BLACK

DIMMING DRIVER WIRING SCHEMES:

DIMMING DRIVER COMPATIBILITY SELECTION GUIDE

D2 / DIML2

1126 River RoadNew Windsor, NY 12553

[email protected]

© 2016. USAI, LLC.All rights reserved. All designs protected by copyright.I2-264-2 Revised 03/22/2017

T 845–565–8500F 845–561–1130USAI

®

Lighting

D2 / DIML2 LED: 0-10V Dimming Driver Wiring (Dims down to 10%)

LED0-10V (-)

0-10V (+)

SWITCHED HOT

NEUTRAL

USAI®

Lighting

D2 / DIML2 0-10V DIMMING W/RELAY TO SWITCH POWER

D2 / DIML2 Dimmer Compatibility Chart Dimmed Light Qty Fixtures Manufacturer Product Part Number Output Range Per Dimmer* 120V / 277V Crestron iLux dimmer expansion module CLS-EXP-DIMFLV 100% - 10% Crestron DIN Rail dimmer DIN-4DIMFLV4 100% - 10% Crestron DIN Rail analog output module DIN-A08 100% - 10% Crestron 8 Channel dimmer module GLX-DIMFLV8 100% - 10% Crestron 8 Channel dimmer module GLXP-DIMFLV8 100% - 10% Leviton IllumaTech dimmer IP710-DLX 100% - 10% Lightolier (Philips) Vega V2000FAMU 100% - 10% Lutron Diva DVTV-XX 100% - 10%

Use source current per fi xture specifi cation sheet to determine number of fi xtures per dimmer. Max number of fi xtures is limited by dimmer load rating.

* NOTE: Refer to dimmer manufacturer's documentation for installation instructions and circuit details.

DIMMER: 0-10V (BY OTHERS)

GRAY

PURPLE

BLACK

WHITE

GREEN

GND

V+ RED

V- BLACK

FIXTURE

DRIVER

LINE

NEUTRAL

CLASS 2 CONTROL WIRES

RELAY (BY OTHERS)

LED0-10V (-)

0-10V (+)

SWITCHED HOT

NEUTRAL

D2 / DIML2 0-10V DIMMING (NO RELAY)

DIMMER: 0-10V w/POWER SWITCHING

(BY OTHERS)

GRAY

PURPLE

BLACK

WHITE

GREEN

GND

FIXTURE

DRIVER

NEUTRAL

LINE

GROUND

NOTE:If switched, non-dimming operation is desired, cap off purple and gray wires individually at installation. Do NOT cap purple and gray wirestogether.

NOTE:If switched, non-dimming operation is desired, cap off purple and gray wires individually at installation. Do NOT cap purple and gray wirestogether.

NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fi xture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specifi c dimmer manufacturer's documentation for details.

IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

1. Keep these instructions in a safe place for future reference. 2. Only qualifi ed electricians in accordance to local codes should install these fi xtures.3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing.4. Make sure all connections are in accordance with the National Electrical Code and any local regulations.5. Cap any wires not used separately (not together).

Page 10: Micro Downlight with Trim - MDF - USAI Lighting

DIMMING DRIVER WIRING SCHEMES:

DIMMING DRIVER COMPATIBILITY SELECTION GUIDE

D3 / DIML3

1126 River RoadNew Windsor, NY 12553

[email protected]

© 2016. USAI, LLC.All rights reserved. All designs protected by copyright.I2-264-3 Revised 03/22/2017

T 845–565–8500F 845–561–1130USAI

®

Lighting

D3 / DIML3 LED: Lutron Hi-Lume A-Series 2 Wire Fwd Phase (with neutral) / LED Dimming Driver Wiring (Dims down to 1%) 120V

USAI®

Lighting

D3 / DIML3 Dimmer Compatibility Chart Dimmed Light Qty Fixtures Per Dimmer* Manufacturer Product Part Number Output Range Fixture Wattage 120V Only 39W and Less 40W - 80W ETC Sensor+ Cabinet ELV10 100% - 1% 1 – 26 1 – 13 ETC Unison DRd Cabinet ELV10 100% - 1% 1 – 26 1 – 13 Lutron Maestro Wireless® 600W dimmer MRF2-6ND-120- 100% - 1% 1 – 8 1 – 4 Lutron Maestro Wireless® 1000W dimmer MRF2-10ND-120- 100% - 1% 1 – 13 1 – 6 Lutron HomeWorks® QS adaptive dimmer HQRD-6NA- 100% - 1% 1 – 8 1 – 4 Lutron HomeWorks® QS 600W dimmer HQRD-6ND- 100% - 1% 1 – 8 1 – 4 Lutron HomeWorks® QS 1000 W dimmer HQRD-10ND- 100% - 1% 1 – 13 1 – 6 Lutron Caseta Wireless® Pro 1000W dimmer PD-10NXD- 100% - 1% 1 – 13 1 – 6 Lutron Stanza® dimmer SZ-6ND- 100% - 1% 1 – 8 1 – 4 Lutron RadioRA® 2 adaptive dimmer RRD-6NA- 100% - 1% 1 – 8 1 – 4 Lutron RadioRA® 2 1000 W dimmer RRD-10ND- 100% - 1% 1 – 6 1 – 3 Lutron myRoom DIN power module MQSE-4A1-D 100% - 1% 1 – 6 1 – 3 Lutron HomeWorks® QS wallbox power module HQRJ-WPM-6D-120- 100% - 1% 1 – 26 1 – 13 Lutron Homeworks® DIN power module LQSE-4A1-D 100% - 1% 1 – 6 1 – 3 Lutron HomeWorks® wallbox power module HWI-WPM-6D-120 100% - 1% 1 – 26 1 – 13 Lutron GRAFIK Eye® QS control unit QSGR-, QSGRJ- 100% - 1% 1 – 26 1 – 13 Lutron GRAFIK Eye® 3000 control unit GRX-3100-, GRX-3500- 100% - 1% 1 – 26 1 – 13 Lutron RPM-4U module HW-RPM-4U-120, LP-RPM-4U-120 100% - 1% 1 – 26 1 – 13 Lutron RPM-4A module HW-RPM-4A-120, LP-RPM-4A-120 100% - 1% 1 – 26 1 – 13 Lutron GP dimming panels Various 100% - 1% 1 – 26 1 – 13 Lutron Ariadni CL 250W dimmer AYCL-253P- 100%-1% 1 – 8 1 – 4 Lutron Diva CL 250W dimmer DVCL-253P-, DVSCCL-253P- 100%-1% 1 – 8 1 – 4 Lutron Grafi k T CL or RF CL dimmer GT-250M-, GTJ-250M- 100%-1% 1 – 8 1 – 4 Lutron Nova T CL 250W dimmer NTCL-250- 100%-1% 1 – 10 1 – 5

* NOTE: Refer to dimmer manufacturer's documentation for installation instructions and circuit details.

LED

SWITCHED HOT

NEUTRAL

D3 / DIML3 2 WIRE PHASE DIMMING

DIMMER: 2 WIRE PHASE(BY OTHERS)

BLACK

WHITE

GREEN

GND

V+ RED

V- BLACK

FIXTURE

DRIVER

NEUTRAL

LINE

GROUND

ONLY FOR SWITCHES WITH NEUTRAL

NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fi xture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specifi c dimmer manufacturer's documentation for details.

IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS1. Keep these instructions in a safe place for future reference. 2. Only qualifi ed electricians in accordance to local codes should install these fi xtures.3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing.4. Make sure all connections are in accordance with the National Electrical Code and any local regulations.5. Cap any wires not used separately (not together).

Page 11: Micro Downlight with Trim - MDF - USAI Lighting

© 2016. USAI, LLC.All rights reserved. All designs protected by copyright.I2-264-6 Revised 08/16/2019

DIMMING DRIVER COMPATIBILITY SELECTION GUIDE

D6A / DIML6A and D6E / DIML6ED6B / DIML6B and D6F / DIML6F

DIMMING DRIVER WIRING SCHEMES:

USAI®

LightingIMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures.3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing.4. Make sure all connections are in accordance with the National Electrical Code and any local regulations.5. Cap any wires not used separately (not together).

LED0-10V (-)

0-10V (+)

SWITCHED HOT

NEUTRAL

D6 / DIML60-10V DIMMING W/RELAY TO SWITCH POWER

DIMMER: 0-10V

GRAY

PURPLE

BLACK

WHITE

GREEN

GND

FIXTURE

DRIVER

LINE

NEUTRAL

CLASS 2 CONTROL WIRES

RELAY (BY OTHERS)

DIML6A, 6B 0-10V DIMMING (NO RELAY)

DIMMER: 0-10V w/POWER SWITCHING

(BY OTHERS)

FIXTURE

V+ RED

V- BLACK

USAI®

Lighting

1126 River RoadNew Windsor, NY 12553

V+ RED

V- BLACK

LED0-10V (-)

0-10V (+)

SWITCHED HOT

NEUTRAL

D6 / DIML60-10V DIMMING (NO RELAY)

DIMMER: 0-10V w/POWER SWITCHING

(BY OTHERS)

GRAY

PURPLE

BLACK

WHITE

GREEN

GND

FIXTURE

DRIVERLINE

GROUND

D6A / DIML6A and D6E / DIML6E LED Dimming Compatibility TableD6A / DIML6A and D6E / DIML6E are linearly programmed dimming drivers for use with the dimming controls listed in the table below.D6A / DIML6A = EldoLED SOLOdrive 0-10V control dims from 100% to 0.1%D6E / DIML6E = EldoLED ECOdrive 0-10V control dims from 100% to 1%

T 845–565–8500F 845–561–1130

NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details.

Dimmed Light Qty Fixtures Manufacturer Product Part Number Output Range Per Dimmer* 120V & 277V DIML6A 6E Lutron Diva DVTV/NFTV with PP-20 99% - 0.1% 1% Lutron Nova T NTFTV with PP-20 99% - 0.1% 1% Lutron Energi Savr Node QSN-4T16-S 100% - 0.1% 1% Lutron GP Dimming Panels TVM2 Module 99% - 0.1% 1% Lutron Interfaces GRX-TVI w/ GRX3503 100% - 0.1% 1% Sensor Switch nIO nIO EZ 100% - 0.1% 1% enlighted Control Unit CU-3E-1R 100% - 0.1% 1%

Refer to manufacturer's dimmer load rating for maximum and minimum fixture quantities per dimmer.Enlighted compatible.

D6A / DIML6A and D6E / DIML6E Dimmer Compatibility Chart

D6B / DIML6B and D6F / DIML6F LED Dimming Compatibility TableD6B / DIML6B and D6F / DIML6F are logarithmic-programmed dimming drivers for use with the dimming controls listed in the table below.D6B / DIML6B = EldoLED SOLOdrive 0-10V control dims from 100% to 0.1% D6F / DIML6F = EldoLED ECOdrive 0-10V control dims from 100% to 1%

D6B / DIML6B and D6F / DIML6F Dimmer Compatibility Chart Dimmed Light Qty Fixtures Manufacturer Product Part Number Output Range Per Dimmer* 120V & 277V DIML6B 6F Bush-Jaeger Electronic potentiometer 2112U-101 100% - 0.1% 1% Jung Electronic potentiometer 240-10 100% - 0.1% 1% Leviton Iluma Tech dimmer IP710-DLX 100% - 0.1% 1% Lightolier (Philips) Momentum (120V ONLY) ZP600FAM120 100% - 0.1% 1% Merten Electronic potentiometer 5729 100% - 0.1% 1% Pass & Seymour Titan CD4FB-W 100% - 0.1% 1% Watt Stopper Miro DCLV1 100% - 0.1% 1% Synergy Wallbox Dimmers ISD BC 100% - 0.1% 1% ABB i-bus SD/S 2.16.1 100% - 0.1% 1% Crestron Modules GLX-DIMFLV8, GLXP-DIMFLV8 100% - 0.1% 1% Crestron Green Light GLPAC-DIMFLV4-, GLPAC-DIMFLV8- 100% - 0.1% 1% Crestron Green Light Power Pack GLPP-DIMFLVEX-PM, GLPP-1DIMFLV2EX-PM, GLPP-1DIMFLV3EX-PM 100% - 0.1% 1% Crestron DIN Rail Analog Output Module DIN-A08 100% - 0.1% 1% Crestron DIN Rail 0-10V Fluorescent Dimmer DIN-4DIMFLV4 100% - 0.1% 1% Crestron iLux 0-10V Dimmer Expansion Module CLS-EXP-DIMFLV 100% - 0.1% 1% enlighted Control Unit CU-3E-1R 100% - 0.1% 1%

Refer to manufacturer's dimmer load rating for maximum and minimum fixture quantities per dimmer.Enlighted compatible.

[email protected]

Page 12: Micro Downlight with Trim - MDF - USAI Lighting

1126 River RoadNew Windsor, NY 12553

[email protected]

© 2016. USAI, LLC.All rights reserved. All designs protected by copyright.I2-264-7 Revised 08/14/2017

T 845–565–8500F 845–561–1130USAI

®

Lighting

DIMMING DRIVER COMPATIBILITY SELECTION GUIDE

D7 / DIML7 and D7EDIMMING DRIVER WIRING SCHEMES:

USAI®

Lighting

D7 / DIML7 and D7E Dimming Driver WiringD7 / DIML7 and D7E are linearly programmed dimming drivers. D7 / DIML7 = EldoLED SOLOdrive DALI control dims from 100% to 0.1%D7E = EldoLED ECOdrive DALI control dims from 100% to 1%

LED

D7 / DIML7 / D7EDALI CONTROLS

V+ RED

V- BLACK

FIXTURE

DRIVER

DALI BUS

WALL CONTROL(BY OTHERS)

LINENEUTRAL

DA

DA

ORANGE (-)ORANGE/WHITE (+)

BLACK WHITE GREEN

GND

NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fi xture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specifi c dimmer manufacturer's documentation for details.

IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS1. Keep these instructions in a safe place for future reference. 2. Only qualifi ed electricians in accordance to local codes should install these fi xtures.3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing.4. Make sure all connections are in accordance with the National Electrical Code and any local regulations.5. Cap any wires not used separately (not together).

Page 13: Micro Downlight with Trim - MDF - USAI Lighting

1126 River RoadNew Windsor, NY 12553

[email protected]

© 2016. USAI, LLC.All rights reserved. All designs protected by copyright.I2-264-8 Revised 08/14/2017

T 845–565–8500F 845–561–1130USAI

®

Lighting

DIMMING DRIVER COMPATIBILITY SELECTION GUIDE

D8 / DIML8 and D8EDIMMING DRIVER WIRING SCHEMES:

USAI®

Lighting

LED

V+ RED

V- BLACK

FIXTURE

DRIVER

REDBLACKBAREBLACKWHITEGREEN

GND

LINE

NEUTRAL

SHIELD

DMX (-)

DMX (+)

DMX BUS - XLR CABLE OR SHIELDED DATA CABLE

5 PIN XLR JACKS STANDARD

8 BIT DMX 512 CONTROLLER

(BY OTHERS)

The data cable used must meet the following requirements: • type: shielded, 2-conductor twisted pair • maximum capacitance between conductors: 30 pF/ft • maximum capacitance between conductor and shield: 55 pF/ft • maximum resistance: 0.02 ohms/ft • normal impedance: 100-140 ohms • conductive core: 24 AWG is recommendedIf 3-wire data cables are preferred, we suggest a Belden 9841 or equivalent cable which meets the specifi cations for EIA RS-485 applications. Do not use standard microphone cables: they cannot transmit DMX512 data reliably over long distances. NOTE: DMX link termination device (by others) should be used on last fi xture in line on a circuit to avoid signal loss.

DMX BUS - XLR CABLE OR SHIELDED DATA CABLE

NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fi xture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specifi c dimmer manufacturer's documentation for details.

IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS1. Keep these instructions in a safe place for future reference. 2. Only qualifi ed electricians in accordance to local codes should install these fi xtures.3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing.4. Make sure all connections are in accordance with the National Electrical Code and any local regulations.5. Cap any wires not used separately (not together).

D8 / DIML8 and D8E Dimming Driver WiringD8 / DIML8 and D8E are linearly programmed dimming drivers. D8 / DIML8 = EldoLED POWERdrive DMX control dims from 100% to 0.1%D8E = EldoLED POWERdrive DMX control dims from 100% to 1%

D8 / DIML8 / D8EDMX CONTROLS

Page 14: Micro Downlight with Trim - MDF - USAI Lighting

D19 / DIML19 LED: Hatch XTC series or equivalent - Forward and Reverse Phase Dimming Driver. Dims down to 1% contingent upon dimmer specifi cation and load. 120V only.

1126 River RoadNew Windsor, NY 12553

[email protected]

© 2016. USAI, LLC.All rights reserved. All designs protected by copyright.I2-264-19 Revised 03/26/2021

T 845–565–8500F 845–561–1130USAI

®

Lighting

DIMMING DRIVER COMPATIBILITY SELECTION GUIDE

D19 / DIML19DIMMING DRIVER WIRING SCHEMES:

USAI®

Lighting

LED

SWITCHED HOT

NEUTRAL

D19 / DIML192 WIRE PHASE DIMMING

DIMMER: 2 WIRE PHASE(BY OTHERS)

BLACK

WHITE

GREEN

GND

V+ RED

V- BLACK

FIXTURE

DRIVER

NEUTRAL

LINE

GROUND

ONLY FOR SWITCHES WITH NEUTRAL

NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details.

IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures.3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing.4. Make sure all connections are in accordance with the National Electrical Code and any local regulations.5. Cap any wires not used separately (not together).

D19 / DIML19 Dimmer Compatibility Chart 120V ONLY Forward Phase / TRIAC Dimming Manufacturer Product Qty Fixtures Per Dimmer Leviton IPL06-10Z Use fixture wattage per 6613-xxx fixture specification Lutron S-600P sheet to determine S-603P number of fixtures DVSC-603P per dimmer. Max number CT-600P of fixtures is limited by CT-603P dimmer load rating.

120V ONLY Reverse Phase / ELV Dimming Manufacturer Product Qty Fixtures Per Dimmer Leviton 6615 Use fixture wattage per IPE04-xxx fixture specification Lutron NTELV-300 sheet to determine NTELV-600 number of fixtures SELV-300P per dimmer. Max number SELV-303P of fixtures is limited by DVELV-300P dimmer load rating. DVELV-303P