Page 1: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

GDC 086R603-001-04Issue 4, 10/17/97

Installation and Operation

Flexi-Voice PlusModel MP 6360

Metroplex ™ 6000

General DataComm

Page 2: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Manual Revision History

Shown below is a chronological listing of revisions to this manual. The issue number, date, and synopsis of revised materials are included to provide the reader with a comprehensive manual history.

Compatibility

Check that you have the required revision of Platform Card firmware and FXS Octet card firmware. See Compatibility on page 3

Note In keeping with the policy of continuing development carried out by General DataComm Inc., the information in this manual is subject to revision without notice.

Issue Date Description1 Jun/96 First issue. This edition describes the Flexi-Voice Plus card2 Nov/96 Updated and reorganized portions of the manual, and added new information on

the Dual OCU-DP and Dual 4W TO option cards3 Apr/97 Updated and Added G.703/64k option card.4 Oct/97 General updates and E1 updates

Page 3: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

GDC 086R603-001-04 i

Flexi-Voice PlusTable of Contents

Flexi-Voice Plus Card............................................................................................................... 1

Front Panel Indicators and Connections................................................................................... 3

Compatibility............................................................................................................................ 3

Installation of Option Cards................................................................................................... 4

Installation of Basecard............................................................................................................. 5

Front Panel Connector Retaining Hardware....................................................................... 6

Dual OB (FXS) Option Card................................................................................................... 7

Application Information..................................................................................................... 8

Diagnostics....................................................................................................................... 12

Dual TB (FXO) Option Card.................................................................................................. 15

Application Information................................................................................................... 15

Diagnostics....................................................................................................................... 18

Dual 4W E&M Option Card................................................................................................... 20

Application Information................................................................................................... 21

Diagnostics....................................................................................................................... 24

Dual 4W TO Option Card....................................................................................................... 27

Application Information................................................................................................... 28

Diagnostics....................................................................................................................... 28

Dual OCU-DP Option Card.................................................................................................... 31

Application Information................................................................................................... 32

Diagnostics....................................................................................................................... 33

Dual G.703/64k Option Card.................................................................................................. 43

Application Information................................................................................................... 43

Diagnostics....................................................................................................................... 45

Wiring Diagram...................................................................................................................... 46

Pinouts..................................................................................................................................... 49

Specifications and Parts List................................................................................................... 51

Page 4: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms
Page 5: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

m the

Flexi-Voice Plus CardThe Flexi-Voice Plus Card provides up to six analog interfaces. The basecard accepts one, two or three dual-channel option cards which provide these interfaces. These interfaces can be voice channels such as FXS, FXO, and E&M or four-wire data channels such as OCU-DP or G.703. Each voice channel appears to a T1 network as a 64 kbps Mu-law encoded PCM channel with robbed-bit signaling. In an E1 network, each channel appears as a 64 kbps A-law encoded PCM channel with Channel Associated Signaling (CAS) in timeslot 16. The OCU-DP channel is a standard DDS channel which occupies one 64 kbps timeslot. The G.703 channel is a standard G.703 64 kbps co-directional channel which occupies one 64 kbps timeslot. Each channel can be assigned to any timeslot on either LIU.

Features

• voice channels such as FXS, FXO and E&M

• four-wire data channels such as OCU-DP and G.703

Configuration

• Interface Type

FXS/LS - for a loop start application

FXS/GS - for a ground start application

DPO (Dial Pulse Originate)

FXO/LS - for a loop start application

FXO/GS - for a ground start application

DPT (Dial Pulse Terminate)

4WE&M

4WTO

OCU-DP

G.703

• Signaling Mode

Standard - for FXS/LS, FXS/GS, and DPO interface types

E&M conversion - for FXS/LS and FXS/GS interface types

PLAR (Private Line Automatic Ringdown) - for FXS/LS interface type

• LIU Assignment

any channel can be assigned to either LIU A or B

• Timeslot

any channel can be assigned to any unused timeslot on either LIU.

• Selectable default TLPs (Transmission Level Point) adjustable in 0.1dB increments frodefault.

J1 (CH1-6)

GDC 086R603-001-04 1

Page 6: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

to the

IS)

RAI,

Diagnostics

• Supports a Card Self-Test

• Supports Conditioning

can force a channel busy.

can force busy on next idle.

can force idle.

Initiated from Manager:

• supports loopback to the network

• supports a digital milliwatt test tone in a system with a CSU or DSX-1 LIU.

a 1000 Hz, 0 dBm0 test tone is transmitted towards the voice channel interface.

If the channel is also in loopback, this test tone can be transmitted in the timeslot network

Initiated from Network:

• 4WTO supports network-initiated tone loopback

• OCU-DP responds to standard network loopback codes

Status

Front panel Indication:

• Idle/Busy status per channel

• Diagnostic status per channel

• In Service status

Displayed on Local Management screen:

• Interface Type

• Signaling Mode

• LIU assignment

• Timeslot

• Idle/Busy

Alarms

• Detects Loss Of Signal on OCU-DP and G.703/64k interfaces

• Detects Loss Of Frame on OCU-DP interface

• Conditions voice and data channels in response to network alarms (LOS, OOF, RAI, Aand network loopbacks.

• Conditions voice channels in response to network timeslot 16 alarms (TS16 OOF, TS16TS16 AIS) on an E1 system.

2 GDC 086R603-001-04

Page 7: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

oice levels,

will

ard

d --

Front Panel Indicators and Connections

Table 1 describes the front panel indicators and electrical connections.

Table 1 Front Panel Indicators and Connectors

Compatibility

Flexi-Voice Plus option cards require a certain revision level of firmware on both the Flexi-VPlus basecard and on the Platform Card for correct operation. To check the firmware revisiongo to the System Utilities screen on the Local Manager. Select Card Revisions . Read the firmware revision level of the Platform Card and the Flexi-Voice Plus Card under the F/W column. The revision level starts at -- and proceeds in the order A-, B-, C-, etc.

If a basecard or option card is not supported by your Platform Card firmware, the card nameappear as Unknown in the Card Type or Option Type heading on the various screens.If an option card is not populated on a basecard, or a basecard is not in a slot, the Card Type or Option Type will appear as -- .

If the firmware revision level of the Flexi-Voice Plus Card is not compatible with the Platform Cfirmware revision level, a “Communication Error ” message may appear. If this occurs, check that the Platform Card and/or the Flexi-Voice Plus Card have up-to-date firmware.

The Flexi-Voice/Flexi-Voice Plus Card (MP6360) -- firmware is compatible with Platform Carfirmware or later.

The Flexi-Voice/Flexi-Voice Plus Card (MP6360) A- firmware or later (which is required to support OCU-DP and 4W TO), requires Platform Card A- or later firmware.

Indicators

LED Use

ON Power on.

OFF = No power to base card.

Green - Has power, and passed its own self-test.

Red - Has power but failed its own self-test.

INS In Service.

OFF = Card not in service. No channels assigned to timeslots.

Green = Card in service. One or more channels are assigned to timeslots.

CH1 - 6 Channel 1 through 6.

OFF = Channel idle. (see each option card for details)

Green = Channel busy. (see each option card for details)

Red = Channel in diagnostic test mode.

Connections

Connector Description

J1 (CH1-6) 50-pin Amphenol connector, RJ2HX female.

GDC 086R603-001-04 3

Page 8: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

can ntries oice (OB,

AT&T

annels option this

rs have nector high-lso has doffs oval

nd help

t ESD

The Flexi-Voice/Flexi-Voice Plus Card (MP6360) D- firmware or later, (which is required to support G.703/64k), requires Platform Card E- or later firmware.

The Flexi-Voice Plus Cards with its various option cards is fully compatible with North AmeriT1 standards. It may also be used in an E1 environment with some limitations. Different coumay require variations in the various analog interfaces which are not supported. The Flexi-VPlus Card supports E1 timeslot 16 Channel Associated Signaling (CAS) for voice interfacesTB, 4W E&M) when the Platform Card is equipped with an E1 LIU. However the signaling protocol used on the A and B signaling bits is the same as the North American T1 standard (Pub 43801, ANSI T1.403-1995). The Flexi-Voice Plus will automatically select Mu-law PCMencoding for T1 and A-law encoding for E1 for OB, TB, 4W E&M and 4WTO interfaces.

Installation of Option CardsThere are no switches or jumpers on the basecard to configure. The number and type of chyou wish to use are selected by plugging in up to three option cards onto the basecard. Eachcard provides for two channels of the same type. Each option card type is described later inchapter. Figure 1 shows the Flexi-Voice Plus basecard with dual voice option cards.

Option cards plug onto the basecard using one or more connectors. The basecard connectosocket (female) contacts and the option card connectors have pin (male) contacts. The conhousing has a small key located at pin 1 to prevent incorrect mating. These surface-mount, density connectors have fragile pins, so they must be handled carefully. Each option card afour plastic snap-in standoffs which secure the card mechanically to the basecard. The stanhave a locking end which remains in the option card, and a non-locking end which allows remof the option card from the basecard. You must make sure that the option card is oriented alocated correctly before attempting installation. One corner of each option card is notched toin orientation, and also one standoff is offset to prevent incorrect installation.

Before handling a card, make sure that you are grounded with an ESD wriststrap, to prevendamage to the card.

Orient the option card so that the notched corner is at the bottom right as shown in Figure 1.

4 GDC 086R603-001-04

Page 9: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

tation. oles in

s snap

rd’s h as the order ectors

card n the

the top

rd will front

Figure 1 Flexi-Voice Plus Basecard With Dual Voice Option Cards

The basecard silkscreen has a notched outline of the option card to help in location and orienPlace the option card over the basecard, locating the four standoffs over the corresponding hthe basecard. Press the four corners of the option card firmly into place until the four standoffinto the holes.

To remove an option card, turn the basecard over and press down on each of the option castandoffs to push the standoffs through the basecard holes. You can use a blunt object sucend of a plastic screwdriver handle. Never use a sharp object or a metal object to do this, into avoid damage to circuit traces or components. When all four standoffs are free, the connwill be unmated, allowing the option card to be lifted off easily.

Installation of BasecardOnce you have properly installed the required option cards, insert the Flexi-Voice Plus baseinto the card guides, pushing on the front panel until the backplane connector mates. Tightetwo captive screws at the top and bottom of the front panel.

To remove a card, loosen the top and bottom captive screws and pull the ring located near of the front panel.

Once you insert a card into a powered system (or when you first power the system up), the caautomatically perform a simple power-on self-test (POST). This test allows you to check the

086P040-001Flexi-Voice Plus Basecard

XA

2J2

XA

1J1

XA

2J1

XA

3J1

XA

1J2

XA

3J2

086P052-001MP6360/EM-1

Dual 4W E&M

086P051-001MP6360/TB-1Dual TB (FXO)

086P050-001MP6360/OB-1Dual OB (FXS)

Channel 1, 2

Channel 3, 4

Channel 5, 6

Note:

J1

Other Option CardsAre Available.

GDC 086R603-001-04 5

Page 10: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

ksum . The

less h the

to the

sends and is

rd.

anel

hown in and

nd the

panel LEDs by turning them red and then green; and it checks that the card’s firmware checis correct. If the self-test passes, the ON LED is turned green; if the test fails, it remains redstatus is also reported in the Status column of the Manager’s Monitor, Diagnostic, and Configuration Slot Selection screens. Since a channel card cannot access the backplane unconfigured by the Platform Card, the power-on self-test does not check the data path througcard.

If you are installing a new card in a system, perform a complete self-test on the card by goingManager’s Diagnostics screen for that card and selecting Card Selftest . The Platform Card then configures the card with a test configuration, performs a ToNet loopback on the card, anda test pattern across the backplane to the card, where it is looped back to the Platform Cardchecked for errors. Both the data and signaling paths are tested. The result of the self-testreported on the Diagnostics screen.

Note that you can run a self-test on all of the cards in the system by selecting Shelf Self-Test in the Diagnostic Slot Selection screen.

Connect a terminal to the TERM port of the Platform Card and configure the Flexi-Voice Plus CaRefer to Local Management - 6.

Front Panel Connector Retaining Hardware

This hardware consists of a retaining plate and screw attached to a dust cover on the front pconnector, and a captive screw screwed into the standoff just above the connector.

Remove the captive screw and use it to replace the long screw on the cable connector as sFigure 2. Remove the screw and retaining plate from the dust cover, discard the dust cover,attach the plate to the cable connector as shown.

The Retaining Plate and the front panel connector clip secure the bottom of the connector ashort screw at the top of the connector screws into the standoff to secure the top.

Figure 2 50-Pin Connector Retaining Kit

Clip

Retaining Plate

Front

50-pin cable

Replace Long Screw

With Short Screw

Replace the originalscrew with the captivescrew from the standoff.

Connector

Panel

Attach the Retaining Plate.

Standoff

6 GDC 086R603-001-04

Page 11: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

ard has

r O

Dual OB (FXS) Option CardCompatibility - This option card is supported with all revisions of the Flexi-Voice Plus Card firmware and Platform Card firmware.

The Dual OB (Originate Battery) option card (Figure 3) provides a two wire voice frequency (VF)interface to telephone equipment such as a telephone set or a PBX trunk. Each OB option ctwo independently configurable voice channels. Features are:

• signaling for FXS (Foreign Exchange Station) Loop Start or Ground Start, Loop Start oGround Start with E&M conversion, PLAR (Private Line Automatic Ringdown), and DP(Dial Pulse Originate)

• selection of any unused timeslot on LIU A or LIU B

• TLP default and adjustment settings

• loopback to network

• digital milliwatt test tone in a system with a CSU or DSX-1 LIU.

• conditioning to a Forced Idle or Forced Busy state

Figure 3 Dual OB Option Card

..........

..

.

....

Key

Dual OB Option Card086P050-001MP6360/OB-1

..........

..

.

....

..........

..

.

....

..........

..

.

....

GDC 086R603-001-04 7

Page 12: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

l, and

an he val

wise it

-hook, of 24 tandby

gher ines

use e loop

to the Bm is

h -15

nd is

to the Bm is

gh -9

Application Information

The Dual OB option card connects to telephone equipment for loop start and ground start applications.

Busy/Idle Indication

The Busy or Idle state of the OB channel is indicated on the front panel LED for that channeon the Local Manager’s Flexi-Voice Plus Monitor screen.

The FXS channel is busy when an off-hook phone causes loop current to flow and initiates outgoing call towards the network; or for an incoming call, when ringing is being applied to tphone. The channel LED will follow the ringing cadence, i.e. it turns off during the silent interbetween rings. The channel is idle when no loop current flows and there is no ringing.

The DPO channel is busy when the loop is seized or when battery polarity is reversed, otheris idle.

Battery Feed

The Dual OB option card provides a battery feed to the telephone loop. When the phone is offthis battery feed provides a constant current of approximately 25 mA from a nominal sourceVDC. This is called Talk Battery. Refer to Table 2 of this manual for maximum loop length. Whenthe phone is on-hook, the battery feed changes to a higher voltage of about 52 VDC, called SBattery.

The lower Talk Battery voltage reduces power consumption in the off-hook state, and the hiStandby Battery voltage provides compatibility with devices such as some answering machwhich require a certain minimum on-hook loop voltage.

TLP Values

The TLP values are entered through the Manager’s Flexi-Voice Plus Configuration screen.

Default 1 (Tx: +3.0dB, Rx: -9.0dB) is used for terminating PSTN service. This is the setting towhen a telephone or analog PBX trunk is connected to the Dual OB option card over a 2-wirwith essentially zero cable loss.

When the voice channel receives a network test tone equal to a digital milliwatt it outputs inanalog voice frequency interface a -9 dBm level. When an analog signal with a level of +3 dinjected into the voice frequency interface it transmits into the network a digital milliwatt.

You can adjust these default TLP values from +9 through -3 dB (transmit) and from -3 througdB (receive) in increments of 0.1 dB.

Default 2 (Tx: +3.0dB, Rx: -3.0dB) is used for dedicated Point-to-Point links where the far ean FXO. This essentially provides a 2-wire to 2-wire extension through the digital network.

When the voice channel receives a network test tone equal to a digital milliwatt it outputs inanalog voice frequency interface a -3 dBm level. When an analog signal with a level of +3 dinjected into the voice frequency interface it transmits into the network a digital milliwatt.

You can adjust these default TLP values from +9 through -3 dB (transmit) and from +3 throudB (receive) in increments of 0.1 dB.

Note Do not connect the Dual OB option card to lines that go outside the building. It is intended for connection to on-premise equipment only.

8 GDC 086R603-001-04

Page 13: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

when with

to the m is

h -12

n.

atible

pplied

ery

ly rrent

tion.

reen.

d there

al OB is is es loop

e the to the y the

ay of least

Default 3 (Tx: 0dB, Rx:-6.0dB) is used for terminating PSTN service. This is the setting to use a telephone or analog PBX trunk is connected to the Dual OB option card over a 2-wire loop3 dB of cable loss.

When the voice channel receives a network test tone equal to a digital milliwatt it outputs inanalog voice frequency interface a -6 dBm level. When an analog signal with a level of 0 dBinjected into the voice frequency interface it transmits into the network a digital milliwatt.

You can adjust these default TLP values from +6 through -6 dB (transmit) and from 0 througdB (receive) in increments of 0.1 dB.

Standard Loop Start

Standard Loop Start is selected through the Manager’s Flexi-Voice Plus Configuration scree

INTERFACE TYPE: ------> FXS/LS

SIGNALING MODE:-------> STND

This mode of operation is used when the far end is an FXO loop start card or is network compwith 43801 signaling.

When the loop is in an idle state (subscriber end equipment is on-hook) standby battery is ato the loop.

When the subscriber end initiates a call it seizes the loop (equipment in off-hook state - battcurrent flows) which signals the network to send dial tone.

When the far end initiates a call it signals the network telling the Dual OB option card to appringing voltage across Tip and Ring. The Dual OB option card waits for the detection of loop cu(Tip and Ring closure by the subscriber equipment going off-hook) to signal the call connec

Standard Ground Start

Standard Ground Start is selected through the Manager’s Flexi-Voice Plus Configuration sc

INTERFACE TYPE: -------> FXS/GS

SIGNALING MODE:-------> STND

This mode of operation is used when the far end is an FXO ground start card or is network compatible with 43801 signaling.

When the loop is in an idle state the subscriber end equipment’s Ring lead is not grounded anis no battery potential across Tip and Ring (open circuit).

When the subscriber end initiates a call it grounds the Ring lead which is detected by the Duoption card. The Dual OB option card then applies battery potential across Tip and Ring. Thdetected by the subscriber end equipment, which then removes the Ring ground, and providclosure. This signals the network to send dial tone.

When the far end initiates a call it signals the network telling the Dual OB option card to closTip lead and so provide battery potential across Tip and Ring. It also applies ringing voltageloop. The Dual OB option card waits for the detection of loop current (Tip and Ring closure bsubscriber equipment going off-hook) to signal the call connection

When the far end hangs up a call, the Dual OB option card will open the Tip lead after a deltwo seconds. This removes Talk Battery from the loop. The Tip lead will remain open for at one second until the next call is initiated.

GDC 086R603-001-04 9

Page 14: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

rk on-

pplied

attery

ly the ply

t (Tip

move nnect l is

rk- on-

d there

al OB ich is es loop

ly the ply

t (Tip

ay of least

Loop Start With E&M Conversion

Loop Start With E&M Conversion is selected through the Manager’s Flexi-Voice Plus Configuration screen.

INTERFACE TYPE: -------> FXS/LS

SIGNALING MODE:-------> CNVSN

This mode of operation is used when the far end is an AT&T 4ESS exchange or uses netwocompatible E&M signaling. In this E&M-like mode, there is only a two-state condition of eitherhook or off-hook.

When the loop is in the idle state (subscriber end equipment is on-hook) standby battery is ato the loop.

When the subscriber end initiates a call, it seizes the loop (equipment in the off-hook state - bcurrent flows) which signals the network which returns dial tone.

When the far end initiates a call, it signals the network telling the Dual OB option card to appcadenced (2 seconds On, 4 seconds Off) ringing voltage across Tip and Ring and also to apRingback tone to the network. The Dual OB option card waits for the detection of loop currenand Ring closure by the subscriber equipment going off-hook) to signal the call connection.

When the far end hangs up a call, after a delay of two seconds the Dual OB option card will reTalk Battery from the loop for a duration of one second and then restore it. This Forward Discoindicates to the subscriber end equipment (modems, answering machines, etc.) that the calterminated.

Ground Start With E&M Conversion

Ground Start With E&M Conversion is selected through the Manager’s Flexi-Voice Plus Configuration screen.

INTERFACE TYPE: -------> FXS/GS

SIGNALING MODE:-------> CNVSN

This mode of operation is used when the far end is an AT&T 4ESS exchange or uses netwocompatible E&M signaling. In this E&M-like mode, there is only a two-state condition of eitherhook or off-hook.

When the loop is in an idle state, the subscriber end equipment’s Ring lead is not grounded anis no battery potential across Tip and Ring (open circuit).

When the subscriber end initiates a call it grounds the Ring lead which is detected by the Duoption card. The Dual OB option card then applies battery potential across Tip and Ring whdetected by the subscriber end equipment, which then removes the Ring ground and providclosure.

When the far end initiates a call it signals the network telling the Dual OB option card to appcadenced (2 seconds On, 4 seconds Off) ringing voltage across Tip and Ring and also to apRingback tone to the network. The Dual OB option card waits for the detection of loop currenand Ring closure by the suscriber equipment going off-hook) to signal the call connection.

When the far end hangs up a call, the Dual OB option card will open the Tip lead after a deltwo seconds. This removes Talk Battery from the loop. The Tip lead will remain open for at one second until the next call is initiated.

10 GDC 086R603-001-04

Page 15: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

i-

n. This

is

attery

ly the ply

f loop

move nnect l is

olarity

current ack by ated

al state.

inging

PLAR Loop Start

PLAR (Private Line Automatic Ringdown) Loop Start is selected through the Manager’s FlexVoice Plus Configuration screen.

INTERFACE TYPE: -------> FXS/LS

SIGNALING MODE:-------> PLAR

This mode of operation is used when the far end is an FXS type card with a phone connectiomode provides a hot-line or ringdown application.

When the loop is in the idle state, subscriber end equipment is on-hook and standby batteryapplied to the loop.

When the subscriber end initiates a call, it seizes the loop (equipment in the off-hook state - bcurrent flows) which signals the far end to ring the phone.

When the far end initiates a call it signals the network telling the Dual OB option card to appcadenced (2 seconds On, 4 seconds Off) ringing voltage across Tip and Ring and also to apRingback tone back to the far end phone. The Dual OB option card waits for the detection ocurrent (Tip and Ring closure by the subscriber equipment going off-hook) to signal the callconnection.

When the far end hangs up a call, after a delay of two seconds the Dual OB option card will reTalk Battery from the loop for a duration of one second and then restore it. This Forward Discoindicates to the subscriber end equipment (modems, answering machines, etc.) that the calterminated.

DPO Loop Start

DPO (Dial Pulse Originate) Loop Start is selected through the Manager’s Flexi-Voice Plus Configuration screen.

INTERFACE TYPE:-------> DPO

SIGNALING MODE:-------> STND

When the loop is in the idle state, the subscriber end equipment is on-hook and the battery pis such that Tip is at ground potential and Ring is at battery potential.

When the subscriber end connects, it seizes the loop (equipment in off-hook state - battery flows) which signals the far end equipment to seize the loop. Answer supervision is passed bmeans of signaling the Dual OB option card to reverse the battery polarity. The call is terminwhen either end goes back on-hook which causes battery polarity to be returned to the norm

Caller-ID

The Dual OB option card passes Caller-ID tones, which are sent from the network between rsignals.

GDC 086R603-001-04 11

Page 16: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

naling

rm Card. n. This oice

nnect tone

Diagnostics

You can perform a loopback test, generate a digital test tone, or force the voice channel sigto a known state in order to verify the functionality of the OB channel. See Figure 4.

Figure 4 Flow Diagram - Dual OB card loopback to network

Card Self-test

Select Card Selftest on the Manager’s Flexi-Voice Plus Diagnostics screen. The PlatfoCard generates a test pattern which it sends in turn to each channel of the Flexi-Voice PlusEach channel is looped back and the Platform Card checks for the correct return of the patterself-test tests both the PCM data and signaling paths and verifies the integrity of the Flexi-VPlus Card and backplane. The pass or fail results are displayed on the screen.

Loopback Test

The Loopback test loops back the signal received from the network back to the network. Cotest equipment at the far end to generate and receive a test tone. Correct receipt of the testverifies the entire voice path from the far end to the OB channel.

BACKPLANE

1000 hertz0dBm test tonefrom Platform Card

Tip

Ring

Platform Card

Flexi-Voice Plus Card

66 E-Block

Network

Dual OB Card(single Channel)

Decoder

Encoder

CODECSLIC

Bat

tery

Transmit Signaling

1 kHz 0 dBm0 Digital Test Tone

VF Interface

Loopback

LIU

12 GDC 086R603-001-04

Page 17: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

by a hook) to be (off-ceive Forced

and only be

if the verify ge the

ted to ce, but el of

it TLP

calls

ic

for 2

Activate the loopback through the Manager’s Flexi-Voice Plus Diagnostic screen.

Local Loopback: ----------> ToNet

During the loopback test, the channel is set to a Forced Idle state for two seconds, followedForced Busy state. Forced Idle causes the signaling towards the network to be the Idle (on-condition which will terminate any call in progress. Forced Idle also causes Standby Batteryapplied to the loop. Forced Busy causes the signaling towards the network to be the Busy hook) state which will prevent new calls from being set up. Forced Busy also ignores any resignaling and causes Talk Battery to be applied to the loop. You can change the state from Busy to Forced Idle after the loopback test is in progress by setting Conditioning to FIdle .

Digital Milliwatt

The digital milliwatt test generates a 1000 Hz 0 dBm0 digital test tone in the Platform Card, sends it to the selected OB channel where it appears on the VF interface. The test tone cangenerated by a Platform Card with CSU or DSX-1 LIUs.

Activate the digital milliwatt test through the Manager’s Flexi-Voice Plus Diagnostic screen.

Dig. MWatt: --------> On

The level of the test tone at the VF interface is equal to the receive TLP level. For example,receive TLP is -3 dB, the level of the test tone will be -3 dBm. Use external test equipment to the correct TLP level. When you activate the test, the channel is forced Busy. You can chanstate from Forced Busy to Forced Idle after the test is in progress by setting Conditioning to FIdle .

Loopback With Digital Milliwatt

On the Manager’s Flexi-Voice Plus Diagnostic screen select

Local Loopback: ----------> ToNet

and

Dig. MWatt: --------> On

to loop the test tone towards the network to the far end. You can use test equipment connecthe channel at the far end to verify the level. The test tone still appears at the local VF interfaat a fixed level of -15 dBm, independent of the receive TLP setting for the channel. The levthe test tone towards the network is at a fixed level of -15 dBm0, independent of the transmsetting. The conditioning is the same as with the Loopback test.

Force Busy Next Idle Condition

Use this test to remove a Flexi-Voice Plus Card’s channel from service without disrupting anyin progress.

Select the Force Busy Next Idle condition through the Manager’s Flexi-Voice Plus Diagnostscreen.

Conditioning: ------> FBNI

After the OB channel has remained in the Idle state (no incoming calls or off-hook requests)seconds, it is placed in a Forced Busy state.

Forced Busy Condition

GDC 086R603-001-04 13

Page 18: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

g or the

.

will es Talk

or the

h will tandby

Use this test to cause the channel to be in a busy condition, independent of receive signalinactual on-hook or off-hook state of the loop.

Select the Forced Busy condition through the Manager’s Flexi-Voice Plus Diagnostic screen

Conditioning: --------> FBusy

Forced Busy causes the signaling towards the network to be the Busy (off-hook) state whichprevent new calls from being set up. Forced Busy also ignores any receive signaling and causBattery to be applied to the loop.

Forced Idle Condition

Use this test to cause the channel to be in an idle condition, independent of receive signalingactual on-hook or off-hook state of the loop.

Select the Forced Idle condition through the Manager’s Flexi-Voice Plus Diagnostic screen.

Conditioning: --------> FIdle

Forced Idle causes the signaling towards the network to be the Idle (on-hook) condition whicterminate any call in progress. Forced Idle ignores any receive signaling and also causes SBattery to be applied to the loop.

14 GDC 086R603-001-04

Page 19: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

l, and

to go

Dual TB (FXO) Option CardCompatibility - This option card is supported with all revisions of the Flexi-Voice Plus Card firmware and Platform Card firmware.

The Dual TB (Terminate Battery) option card (Figure 5) provides a two-wire voice frequency (VF)interface to C.O. subscriber lines or to PBX extension lines. Each TB option card has two independently configurable voice channels. Features are:

• signaling for Loop Start or Ground Start, and DPT

• selection of any unused timeslot on LIU A or LIU B

• 600 or 900 ohm termination

• TLP default and adjustment settings

• loopback towards the network

• digital milliwatt test tone in a system with a CSU or DSX-1 LIU

• conditioning of the channel to a Forced Idle or Forced Busy state

Figure 5 Dual TB Option Card

Application Information

Busy/Idle Indication

The Busy or Idle state of the TB channel is indicated on the front panel LED for that channeon the Local Manager’s Flexi-Voice Plus Monitor screen.

The channel is busy when an incoming call from the network causes the Dual TB option card

..........

..

.

....

Key

Dual TB Option card

.........

..

.

....

086P051-001MP6360/TB-1

CH 1 X1

X2900600

CH 2 X3X4

600

900

default position

Before installing the TB option card onto the basecard, select the type of termination for each channelusing jumpers X1, X2, X3, and X4. The 600 ohm termination is the most common. After the card has been properly installed, you can verify the setting through the Manager’s Flexi-Voice Plus Monitor screenImpedance: (OHMS)--------> * 600 or 900

..........

..

.

....

..........

..

.

....

.

GDC 086R603-001-04 15

Page 20: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

Note en tected

is an

uts of +3 att.

gh -9

uts of +0 att.

h -15

n.

atible

ith Tip nts a

Dual he goes the

B l tone.

reen.

off-hook; or when ringing is detected by the Dual TB option card to initiate an outgoing call. that the LED will follow the ringing cadence, i.e. it will turn off during the silent interval betwerings. The channel is idle when the Dual TB option card is on-hook and there is no ringing deby the card.

TLP Values

The TLP values are entered through the Manager’s Flexi-Voice Plus Configuration screen.

Default 1 (Tx: +3 dB, Rx: -3 dB) is used for dedicated Point-to-Point links where the far end FXS. This essentially provides a 2-wire to 2-wire extension through the digital network.

When the Dual TB option card receives a network test tone equal to a digital milliwatt it outpinto the analog voice frequency interface a -3 dBm level. When an analog signal with a leveldBm is injected into the voice frequency interface it transmits into the network a digital milliw

You can adjust these default TLP values from +9 through -3 dB (transmit) and from -1 throudB (receive) in increments of 0.1 dB.

Default 2 (Tx: 0 dB, Rx: -9 dB) is used for terminating PSTN service.

When the Dual TB option card receives a network test tone equal to a digital milliwatt it outpinto the analog voice frequency interface a -9 dBm level. When an analog signal with a leveldBm is injected into the voice frequency interface it transmits into the network a digital milliw

You can adjust these default TLP values from +6 through -6 dB (transmit) and from -3 througdB (receive) in increments of 0.1 dB.

Standard Loop Start

Standard Loop Start is selected through the Manager’s Flexi-Voice Plus Configuration scree

INTERFACE TYPE: ------> FXO/LS

SIGNALING MODE:-------> STND

This mode of operation is used when the far-end is an FXS loop start card or is network compwith 43801 signaling.

When the loop is in an idle state, the office end equipment (exchange) provides a battery wat ground and Ring at the battery potential. The Dual TB option card is on-hook which presehigh impedance to the loop (no battery current flowing).

When the office end equipment (exchange) initiates a call it applies a ringing voltage to the TB option card. This ring detection by the Dual TB option card signals the far end (through tnetwork) which allows the FXS card to apply a ringing voltage to the phone. When the far endoff-hook the network signaling allows the Dual TB option card to go off-hook thus completingcall.

When the far end initiates a call it goes off-hook which signals the network telling the Dual Toption card to seize the loop (TB off-hook). The office end equipment (exchange) sends dia

Standard Ground Start

Standard Ground Start is selected through the Manager’s Flexi-Voice Plus Configuration sc

INTERFACE TYPE: -------> FXO/GS

SIGNALING MODE:-------> STND

16 GDC 086R603-001-04

Page 21: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

battery

his lows twork

Dual cts to e far-

oop und

n

ntial card attery

sion.

This mode of operation is used when the far end is an FXS ground start card or is network compatible with 43801 signaling.

When the loop is in an idle state the office end equipment opens the Tip lead and there is no potential across Tip and Ring. The Dual TB option card is on-hook which presents a high impedance to the loop.

When the office end initiates a call it supplies a ringing voltage to the Dual TB option card. Tring detection by the Dual TB option card signals the far end (through the network) which althe FXS card to apply a ringing voltage to the phone. When the far end goes off-hook the nesignaling allows the Dual TB option card to go off-hook thus completing the call.

When the far end initiates a call it receives a Ring ground that signals the network telling theTB option card to ground the Ring lead to the office equipment. The office end equipment reathe Ring ground by applying Tip ground which the Dual TB option card detects and signals thend (through the network) to apply Tip ground to its interface. When the far-end seizes the l(goes off-hook) it signals (through the network) the Dual TB option card to remove Ring groand go off-hook thus completing the connection.

DPT

DPT (Dial Pulse Terminate) is selected through the Manager’s Flexi-Voice Plus Configuratioscreen.

INTERFACE TYPE:-------> DPT

SIGNALING MODE:-------> STND

One common application for DPT is for DID (Direct Inward Dialing) service.

The Dual TB option card connects to a PBX trunk which provides battery (Tip at ground poteand Ring at battery potential). An incoming call from the network causes the Dual TB optionto seize the loop. The PBX detects loop current and responds by toggling the polarity of the bto transmit a wink to the network. The network then sends dial pulses to dial the PBX extenDial pulses are transmitted by the Dual TB option card by opening and closing the loop.

GDC 086R603-001-04 17

Page 22: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

naling

rm Card. n. This oice

nnect tone

by a hook)

Diagnostics

You can perform a loopback test, generate a digital test tone, or force the voice channel sigto a known state in order to verify the functionality of the TB channel. See Figure 6.

.

Figure 6 Flow Diagram - Dual TB card loopback to network

Card Self-test

Select Card Selftest on the Manager’s Flexi-Voice Plus Diagnostics screen. The PlatfoCard generates a test pattern which it sends in turn to each channel of the Flexi-Voice PlusEach channel is looped back and the Platform Card checks for the correct return of the patterself-test tests both the PCM data and signaling paths and verifies the integrity of the Flexi-VPlus Card and backplane. The pass or fail results are displayed on the screen.

Loopback Test

The Loopback test loops back the signal received from the network back to the network. Cotest equipment at the far end to generate and receive a test tone. Correct receipt of the testverifies the entire voice path from the far end to the TB channel.

Activate the loopback through the Manager’s Flexi-Voice Plus Diagnostic screen.

Local Loopback: ----------> ToNet

During the loopback test, the channel is set to a Forced Idle state for two seconds, followedForced Busy state. Forced Idle causes the signaling towards the network to be the Idle (on-

BACKPLANE

1000 hertz0dBm test tonefrom Platform Card

Platform Card

Flexi-Voice Plus Card

T1 Network

Dual TB Card(single Channel)

Decoder

Encoder

CODEC

Transmit Signaling

1 kHz 0 dBm0 Digital Test Tone

VF Interface

Loopback

LIU

StationT (Tip)

R (Ring)

Off-HookOn-Hook

Hybrid

Transformer

C.O.

66 E-Block

18 GDC 086R603-001-04

Page 23: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

card -hook) naling pback

and only be

if the verify ge the

ted to ce, but el of

it TLP

ic

) for

g

.

k

condition which will terminate any call in progress. Forced Idle also causes the Dual TB optionto open the loop. Forced Busy causes the signaling towards the network to be the Busy (offstate which will prevent new calls from being set up. Forced Busy also ignores any receive sigand seizes the loop. You can change the state from Forced Busy to Forced Idle after the lootest is in progress by setting Conditioning to FIdle .

Digital Milliwatt

The digital milliwatt test generates a 1000 Hz 0 dBm0 digital test tone in the Platform Card, sends it to the selected TB channel where it appears on the VF interface. The test tone can generated by a Platform Card with CSU or DSX-1 LIUs.

Activate the digital milliwatt test through the Manager’s Flexi-Voice Plus Diagnostic screen.

Dig. MWatt: --------> On

The level of the test tone at the VF interface is equal to the receive TLP level. For example,receive TLP is -3 dB, the level of the test tone will be -3 dBm. Use external test equipment to the correct TLP level. When you activate the test, the channel is forced Busy. You can chanstate from Forced Busy to Forced Idle after the test is in progress by setting Conditioning to FIdle .

Loopback With Digital Milliwatt

On the Manager’s Flexi-Voice Plus Diagnostic screen select

Local Loopback: ----------> ToNet

and

Dig. MWatt: --------> On

to loop the test tone towards the network to the far end. You can use test equipment connecthe channel at the far end to verify the level. The test tone still appears at the local VF interfaat a fixed level of -15 dBm, independent of the receive TLP setting for the channel. The levthe test tone towards the network is at a fixed level of -15 dBm0, independent of the transmsetting. The conditioning is the same as with the Loopback test.

Force Busy Next Idle Condition

Use this test to remove a TB channel from service without disrupting any calls in progress.

Select the Force Busy Next Idle condition through the Manager’s Flexi-Voice Plus Diagnostscreen.

Conditioning: ------> FBNI

After the TB channel has remained in the Idle state (no incoming calls or detection of ringing6 seconds, it is placed in a Forced Busy state.

Forced Busy Condition

Use this test to cause the channel to be in a busy condition, independent of receive signalin

Select the Forced Busy condition through the Manager’s Flexi-Voice Plus Diagnostic screen

Conditioning: --------> FBusy

Forced Busy seizes the line, independent of receive signaling, and sends the correct off-hoosignaling state to the network.

GDC 086R603-001-04 19

Page 24: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

or the

d also

e ntly

Forced Idle Condition

Use this test to cause the channel to be in an idle condition, independent of receive signalingpresence of ringing voltage on the loop.

Select the Forced Idle condition through the Manager’s Flexi-Voice Plus Diagnostic screen.

Conditioning: --------> FIdle

Forced Idle keeps the loop in an idle (on-hook) conditions, ignoring any receive signaling, ancauses the signaling towards the network to be the Idle (on-hook, no ringing) condition.

Dual 4W E&M Option CardCompatibility - This option card is supported with all revisions of the Flexi-Voice Plus Card firmware and Platform Card firmware.

The Dual 4-W E&M Option Card shown in Figure 7 provides a four-wire voice frequency interfacto switching equipment such as a PBX. Each Dual 4W E&M option card has two independeconfigured voice channels. Features are:

• E&M signaling Types I, II, III, and V (using on-card jumpers X1 and X2)

• can be assigned to any unused timeslot on LIU A or LIU B

• TLP default and adjustment settings

• loopback to network

• digital milliwatt test tone in a system with a CSU or DSX-1 LIU

• conditioning to a Forced Idle or Forced Busy state

Figure 7 Dual 4-Wire E&M Option Card

..........

..

.

....

Key

X1

X2

Dual 4-W E&M Option Card086P052-001MP6360/EM-1

IV

III II

Jumpers shown in default position Type I

................

CH1

CH2

Before installing the Dual 4W E&M option card onto the Flexi-Voice Plus basecard, select the type of E&M signaling for each channel using jumpers X1 and X2. The E&M signaling type I, II, III or V should match the signaling type of the PBX. Type I is the most common. After the card has been

properly installed, you can verify the setting of the E&M Type through the Manager’s Flexi-VoicePlus Monitor screen. (Signaling Type:-------->* TYPE (I, II, III, V )

..........

..

.

....

..........

..

.

....

.

20 GDC 086R603-001-04

Page 25: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

nnel,

for an

t it a level

rough

it ith a igital

8.5

ing in the

must g

Application Information

The Dual 4W E&M option card interfaces with a PBX or key system.

Busy/Idle Indication

The Busy or Idle state of the 4W E&M channel is indicated on the front panel LED for that chaand on the Local Manager’s Flexi-Voice Plus Monitor screen.

The channel is busy when the M-lead is busy for an outgoing call, or when the E-lead is busyincoming call. The channel is idle when neither the M-lead nor the E-lead is busy.

TLP Values

The TLP values are entered through the Manager’s Flexi-Voice Plus Configuration screen.

Default 1 (Tx: 0 dB, Rx: 0 dB) is used for connecting to a (0/0) PBX.

When the Dual 4 W E&M option card receives a network test tone equal to a digital milliwatoutputs into the analog voice frequency interface a 0 dBm level. When an analog signal with of 0 dBm is injected into the voice frequency interface it transmits into the network a digital milliwatt.

You can adjust these default TLP values from +1.5 through -8 dB (transmit) and from +1.5 th-8 dB (receive) in increments of 0.1 dB.

Default 2 (Tx: -16 dB, Rx: +7 dB) is used for connecting to a (-16/+7) PBX.

When the Dual 4W E&M option card receives a network test tone equal to a digital milliwattoutputs into the analog voice frequency interface a +7 dBm level. When an analog signal wlevel of -16 dBm is injected into the voice frequency interface it transmits into the network a dmilliwatt.

You can adjust these default TLP values from -8 dB through -17.5 dB (transmit) and from +through -1 dB (receive) in increments of 0.1 dB.

E&M Signaling

E&M Type I and Type V signaling require a separate ground connection between the switchequipment (PBX) and the transmission equipment (Metroplex™ 6000), for the return current E and M signaling leads. On the Metroplex™ 6000, this return path is labeled E&M-GND on the rear of the Wallmount Enclosure or the Universal System Shelf near the terminal block. Youmake sure that a connection is made between E&M-GND and the reference ground of the switchinequipment when using E&M Type I or V. Figure 8 through Figure 11 shows the E&M signaling types and their busy and idle states.

Note Do not connect the Dual 4 W E&M option card to lines that go outside the building. It is intended for connection to on-premise equipment only.

GDC 086R603-001-04 21

Page 26: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

Figure 8 Type I E&M Signaling Connections

Figure 9 Type II E&M Signaling Connections

M-LeadDetector

E-Lead Driver

idle

busy

INTERFACE POINT

Note: The connecting equipment groundmust be connected to the E&M GND ground.

M-Lead Driver

idle

busy

-48V

E-Lead Detector

Ground

-48V

Connecting Equipment

M

E

E&M GND

+

+

Metroplex™ 6000

-48V

_

M-LeadDetector

CurrentLimiter

Connecting Equipment

INTERFACE POINT

M-Lead Driver

idle

busy

idle

busy

E-LeadDetector

-48V

+

Ground

-

E-Lead Driver

Note: The unit and connecting equipment use separate grounds.

SB

M

E

SG

+

Metroplex™ 6000

22 GDC 086R603-001-04

Page 27: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

Figure 10 Type III E&M Signaling Connections

Figure 11 Type V E&M Signaling Connections

-48V

_

M-LeadDetector

CurrentLimiter

Connecting Equipment

INTERFACE POINT

M-Lead Driver

idle

busy

idle

busyE-LeadDetector

-48V

+

-E-Lead Driver

Note: The unit and connecting equipment use separate grounds.

SB

M

E

SG

+

Ground

Metroplex™ 6000

M-Lead

Connecting Equipment

idle

busy

M-Lead Driver

Detector

busy

idle

E-LeadDetector

GroundINTERFACE POINT

Note: The connecting equipment ground

must be connected to the E&M GND ground.

M

E

E&M GND

+ 48 V

+ 48 V

Metroplex™ 6000

GDC 086R603-001-04 23

Page 28: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

naling

rm Card. n. This oice

nnect tone

Diagnostics

You can perform a loopback test, generate a digital test tone, or force the voice channel sigto a known state in order to verify the functionality of the 4W E&M channel. See Figure 12

.

Figure 12 ToNet loopback - Dual 4W E&M Card

Card Self-test

Select Card Selftest on the Manager’s Flexi-Voice Plus Diagnostics screen. The PlatfoCard generates a test pattern which it sends in turn to each channel of the Flexi-Voice PlusEach channel is looped back and the Platform Card checks for the correct return of the patterself-test tests both the PCM data and signaling paths and verifies the integrity of the Flexi-VPlus Card and backplane. The pass or fail results are displayed on the screen.

Loopback Test

The loopback test loops back the signal received from the network back to the network. Cotest equipment at the far end to generate and receive a test tone. Correct receipt of the testverifies the entire voice path from the far end to the 4W E&M channel.

BACKPLANE

1000 hertz0dBm test tonefrom Platform Card

Platform Card

Flexi-Voice Plus Card

66 E-Block

Network

Dual 4W E&M Card(single Channel)

Decoder

Encoder

CODEC

Transmit Signaling

1 kHz 0 dBm0 Digital Test Tone

VF Interface

Loopback

PBX

T (Tip)

R (Ring)

Idle

Transformers

TI

RI

EMSBSG

Busy

E-Lead

LIU

24 GDC 086R603-001-04

Page 29: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

le d is sy to

and e can

if the verify ge the

ted to ce, but el of

it TLP

ress.

ic

g or the

.

Activate the loopback through the Manager’s Flexi-Voice Plus Diagnostic screen.

Local Loopback: ----------> ToNet

During the loopback test, the channel is set to a Forced Idle state (the E-lead is open and idsignaling is sent to the network) for two seconds, followed by a Forced Busy state (the E-leaclosed and busy signaling is sent to the network). You can change the state from Forced BuForced Idle after the loopback test is in progress by setting Conditioning to FIdle .

Digital Milliwatt

The digital milliwatt test generates a 1000 Hz 0 dBm0 digital test tone in the Platform Card, sends it to the selected 4W E&M channel where it appears on the VF interface. The test tononly be generated by a Platform Card with CSU or DSX-1 LIUs.

Activate the digital milliwatt test through the Manager’s Flexi-Voice Plus Diagnostic screen.

Dig. MWatt: --------> On

The level of the test tone at the VF interface is equal to the receive TLP level. For example,receive TLP is -3 dB, the level of the test tone will be -3 dBm. Use external test equipment to the correct TLP level. When you activate the test, the channel is forced Busy. You can chanstate from Forced Busy to Forced Idle after the test is in progress by setting Conditioning to FIdle .

Loopback With Digital Milliwatt

On the Manager’s Flexi-Voice Plus Diagnostic screen select

Local Loopback: ----------> ToNet and

Dig. MWatt: --------> On

to loop the test tone towards the network to the far end. You can use test equipment connecthe channel at the far end to verify the level. The test tone still appears at the local VF interfaat a fixed level of -15 dBm, independent of the receive TLP setting for the channel. The levthe test tone towards the network is at a fixed level of -15 dBm0, independent of the transmsetting. The conditioning is the same as with the Loopback test.

Force Busy Next Idle Condition

Use this test to remove a 4W E&M channel from service without disrupting any calls in prog

Select the Force Busy Next Idle condition through the Manager’s Flexi-Voice Plus Diagnostscreen.

Conditioning: ------> FBNI

After the 4W E&M channel has remained in the Idle state (M-lead and E-lead both idle) for 6seconds, it is placed in a Forced Busy state.

Forced Busy Condition

Use this test to cause the channel to be in a busy condition, independent of receive signalinM-lead input.

Select the Forced Busy condition through the Manager’s Flexi-Voice Plus Diagnostic screen

Conditioning: --------> FBusy

GDC 086R603-001-04 25

Page 30: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

y state,

or the

tate,

Forced Busy closes the E-lead and causes the signaling towards the network to be the Busignoring the actual state of the M-lead.

Forced Idle Condition

Use this test to cause the channel to be in a idle condition, independent of receive signalingM-lead input.

Select the Forced Idle condition through the Manager’s Flexi-Voice Plus Diagnostic screen.

Conditioning: --------> FIdle

Forced Idle opens the E-lead and causes the signaling towards the network to be the Idle signoring the actual state of the M-lead.

26 GDC 086R603-001-04

Page 31: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

and

ncy ng ndent

n this

Dual 4W TO Option CardCompatibilit y - This option card requires Flexi-Voice Plus Card firmware revision A- or later, Platform Card firmware revision A- or later.

The Dual 4W TO (four-wire, transmission only) option card provides two 4-wire voice frequeinterfaces. It is similar to a 4W E&M option card except that it does not provide E&M signalileads, and does not use robbed-bit signaling. Each Dual 4W TO option card has two indepeconfigurable voice channels. Features are:

• assignment to any unused timeslot on LIU A or LIU B

• TLP default and adjustment settings

• Network-initiated tone loopback

• Selection of 2713 or 2813 Hz loopback tone

• Selection of 4 or 20 minutes loopback time-out

• digital milliwatt test tone in a system with a CSU or DSX-1 LIU

Figure 13 shows the layout of the Dual 4W TO option card. There are no hardware options ocard.

Figure 13 Dual 4W TO Option Card

..........

..

.

....

Key

Dual 4W TO Option Card086P053-001M6360/4W TO

.........

..

.

....

..........

..

.

....

..........

..

.

....

.

GDC 086R603-001-04 27

Page 32: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

with a igital .

ith a igital

rm Card. n. This oice

e

Application Information

TLP Values

The TLP values are entered through the Manager’s Flexi-Voice Plus Configuration screen.

Default 1 (Tx: +10 dB, Rx: -3 dB) is used for terminating 4-wire leased line modems.

When the Dual 4W TO option card receives a network test tone equal to a digital milliwatt ittransmits into the analog voice frequency interface a -3.0 dBm level. When an analog signallevel of +10 dBm is injected into the voice frequency interface it transmits into the network a dmilliwatt. These default TLP values allow a total adjustment value of +16.0 through +6.5 dB(transmit) and +1.5 through -11.0 dB (receive) that can be controlled in increments of 0.1 dB

Default 2 (Tx: 0 dB, Rx: 0 dB) is used for terminating 4-wire leased line modems.

When the Dual 4W TO option card receives a network test tone equal to a digital milliwatt ittransmits into the analog voice frequency interface a 0 dBm level. When an analog signal wlevel of 0 dBm is injected into the voice frequency interface it transmits into the network a dmilliwatt. These default TLP values allow a total adjustment value of +6.5 through -3.0 dB (transmit) and +8.0 through -1.5 dB (receive) that can be controlled in increments of 0.1 dB.

Diagnostics

The Dual 4W TO option card supports the following manager-initiated diagnostics:

• Loopback towards the network

• Digital milliwatt test tone in a system with a CSU or DSX-1 LIU

It also supports a network-initiated tone loopback.

Card Self-test

Select Card Selftest on the Manager’s Flexi-Voice Plus Diagnostics screen. The PlatfoCard generates a test pattern which it sends in turn to each channel of the Flexi-Voice PlusEach channel is looped back and the Platform Card checks for the correct return of the patterself-test tests both the PCM data and signaling paths and verifies the integrity of the Flexi-VPlus Card and backplane. The pass or fail results are displayed on the screen.

Manager-Initiated Loopback

See Figure 14. This loops the signal received from the network back towards the network. Thsignal also appears on the 4-wire interface. The loopback point is in the codec

Activate the loopback through the Manager’s Flexi-Voice Plus Diagnostic screen.

Local Loopback: ----------> ToNet

Note Do not connect the Dual 4W TO option card to lines that go outside the building. It is intended for connection to on-premise equipment only.

28 GDC 086R603-001-04

Page 33: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

rface.

if the verify

ted to ce, but el of

it TLP

Digital Milliwatt

See Figure 14. The Digital milliwatt test generates a 1000 Hz 0 dBm0 digital test tone in the Platform Card, and sends it to the selected 4W TO channel where it appears on the VF inteThe test tone can only be generated by a Platform Card with CSU or DSX-1 LIUs.

Activate the digital milliwatt test through the Manager’s Flexi-Voice Plus Diagnostic screen.

Dig. MWatt: --------> On

The level of the test tone at the VF interface is equal to the receive TLP level. For example,receive TLP is -3 dB, the level of the test tone will be -3 dBm. Use external test equipment to the correct TLP level.

Loopback With Digital Milliwatt

On the Manager’s Flexi-Voice Plus Diagnostic screen select

Local Loopback: ----------> ToNet

and

Dig. MWatt: --------> On

to loop the test tone towards the network to the far end. You can use test equipment connecthe channel at the far end to verify the level. The test tone still appears at the local VF interfaat a fixed level of -15 dBm, independent of the receive TLP setting for the channel. The levthe test tone towards the network is at a fixed level of -15 dBm0, independent of the transmsetting.

GDC 086R603-001-04 29

Page 34: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

13 or e card iod can tes if a

onds at m the e side lected time-lights

Figure 14 Test Configuration - Dual 4W TO Card

Network-Initiated Loopback

The Dual 4W TO card will also perform a loopback towards the network in response to a 272813 Hz tone sent from the network. There are two configurable parameters for this test. Thcan be set to respond to a test tone frequency of either 2713 or 2813 Hz, and the time-out perbe set to either 4 or 20 minutes. The time-out causes the loopback to end after 4 or 20 minusecond tone was not received to end the loopback.

In the Manager’s Flexi-Voice Plus Configuration screen, select

Network Loopback Freq(Hz): ----> 2713 or 2813

Network Loopback Timeout(Min): ------> 4 or 20 .

To start the loopback, the network sends a tone of the selected frequency for at least 2.5 seca level between 0 and -16 dBm0. Once the tone is removed, the Dual 4W TO card will perforloopback towards the network. The loopback is implemented by relays on the 4-wire interfacof the transformers. It then remains in a loopback state until either a second tone of the sefrequency, with a level between 0 and -16 dBm0, is received for at least 0.5 seconds, or theout expires. When the loopback is in effect, the 4-wire interface is cut off, the front panel LED Red to indicate test mode, and the Manager’s Flexi-Voice Plus Monitor screen reports

Local Loopback ----> Network .

BACKPLANE

1000 hertz0dBm test tonefrom Platform Card

Platform Card

Flexi-Voice Plus Card

66 E-Block

Network

Dual 4W TO Card(single Channel)

Decoder

Encoder

CODEC

Transmit Signaling

1 kHz 0 dBm0 Digital Test Tone

4-Wire Interface

ToNet Loopback

Modem

T (Tip)

R (Ring)

Transformer

TI

RI

LIU

NetworkLoopback

Transformer

30 GDC 086R603-001-04

Page 35: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

t be s in

and

ith ach

:

Note that if the digital milliwatt test is in progress, the loopback tone from the network will nodetected until the digital milliwatt test is ended. Also, if the Manager-Initiated loopback test iprogress, the Network-Initiated loopback will still be implemented.

Dual OCU-DP Option CardCompatibility - This option card requires Flexi-Voice Plus Card firmware revision A- or later, Platform Card firmware revision A- or later.

The Dual OCU-DP (Office Channel Unit - Data Port) option card (Figure 15) provides a four-wire interface to a DSU. It is compatible with standard Dataphone Digital Service (DDS), DDS wSecondary Channel (DDS/SC), DDS 64k clear channel, and Switched 56 (SW56) Service. EDual OCU-DP option card has two independently configurable data channels. Features are

• data rates of 2.4, 4.8, 9.6, 19.2, 56 or 64 kbps

• assignment of any unused timeslot on LIU A or B

• DDS or SW56 service

• Secondary Channel on or off (always off with SW56 or DDS 64 kbps)

• ZCS (Zero Code Suppression) enable or disable

• responds to DDS network loopbacks

• response to latching loopback codes can be enabled or disabled

Figure 15 Dual OCU-DP Option Card

..........

..

.

....

Key

Dual OCU-DP Option Card086P054-001MP6360/OCU-DP1

..........

..

.

....

..........

..

.

....

..........

..

.

....

GDC 086R603-001-04 31

Page 36: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

also not

and 1-

DDS ith nd 64 .

Us

nnel,

nnel is g a

Application Information

The Dual OCU-DP option card is fully compatible with North American T1 standards. It may be used in an E1 environment with some limitations. For instance, DDS network codes arestandard for E1 networks. Channels may be assigned to timeslots in the ranges 1-24 for T130 for E1.

The Dual OCU-DP is a cost-effective 4-wire solution to the provisioning and maintenance of or SW56 services. The Dual OCU-DP is capable of operating in Standard DDS and DDS wSecondary Channel. In DDS it can operate at synchronous rates of 2.4, 4.8, 9.6, 19.2, 56, akbps. In DDS/SC it can operate at synchronous data rates of 2.4, 4.8, 9.6, 19.2 and 56 kbps

As shown in Figure 16, the Dual OCU-DP allows data to be distributed on 4-wire loops to DSlocated throughout a building.

Figure 16 Typical OCU-DP Application

Busy/Idle Indication

The Busy or Idle state of the OCU-DP channel is indicated on the front panel LED for that chaand on the Manager’s Flexi-Voice Plus Monitor screen.

The channel is busy when the attached DSU is in Data Mode towards the network. The chaidle when the DSU is in control mode towards the network. The front panel LED is Off durinLoss Of Signal (LOS) alarm or a Loss of Framing (LOF) alarm on the 4-wire interface.

Note Do not assign timeslot 31 to an OCU-DP channel in an E1 system.

Note Do not connect the Dual OCU-DP option card to lines that go outside the building. It is intended for connection to on-premise equipment only.

Flexi-Voice

Channels 3 & 4

Dual OCU-DPChannels 1 & 2

Channels 5 & 6

Dual OCU-DP

Dual OCU-DP

4-WireLoop DTE

DSU/CSU

Customer Premises

Plus Basecard

T1Network

Metroplex™ 6000

32 GDC 086R603-001-04

Page 37: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

f the nsmit back, owards nced

ming. four-

ands

this d by

h

T1

or

rm Card. n. This oice

DC Sealing Current

The Dual OCU-DP option card provides a DC sealing current for activation or deactivation oCSU Loopback at the DSU/CSU. In normal operation (CSU Loopback not activated), the trapair (T,R) is kept positive with respect to the receive pair (T1, R1). To activate the CSU Loopthe OCU-DP reverses the polarity, which is sensed by the DSU/CSU and causes a loopback tthe OCU-DP. The DC sealing current is sourced from a 24 VDC internal supply, is DC refereto signal ground and the maximum short-circuit current is 21 mA

.Timing

The external DSU/CSU must be loop timed (synchronized) to the Metroplex™ 6000 system tiThe DSU/CSU does this by deriving its transmit timing from the receive signal present at itswire interface.

Configuration

Latching Loopback Enable or Disable

Enable - Allows the Dual OCU-DP option card to respond to inband latching loopback commfrom the Serving Test Center (STC).

Disable - The Dual OCU-DP will not respond to the inband latching loopback commands. Usesetting if you need to prevent accidental loopback activation which can sometimes be causeimitation of the loopback codes by customer data.

ZCS (Zero Code Suppression) Enable or Disable

Enable - Allows the Dual OCU-DP option card to overwrite an all-zeros byte (00000000) wit(00011000). This prevents strings of zeros from being transmitted toward the network.

Disable - The Dual OCU-DP will not overwrite an all-zeros byte. Always select disable if theline uses B8ZS Coding or for use in an E1 network.

Diagnostics

Figure 17 through Figure 25 illustrate loopback tests that you may perform from the manager network.

Card Self-test

Select Card Selftest on the Manager’s Flexi-Voice Plus Diagnostics screen. The PlatfoCard generates a test pattern which it sends in turn to each channel of the Flexi-Voice Plus Each channel is looped back and the Platform Card checks for the correct return of the patterself-test tests both the PCM data and signaling paths and verifies the integrity of the Flexi-VPlus Card and backplane. The pass or fail results are displayed on the screen.

GDC 086R603-001-04 33

Page 38: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

ct LED ack is

to the

Manager-Initiated Loopbacks

ToChan Loopback

Use external test equipment (or the DSU/CSU) to generate and detect the test pattern. SeleToChan on the Flexi-Voice Plus Four-Wire Data Channel Diagnostic screen. The front panelcorresponding to the channel performing the loopback lights red indicating the ToChan loopbengaged.

This loopback test verifies the integrity of the option card and the cables. The transmit data network is marked.

Figure 17 Manager-initiated - To Chan Loopback

BACKPLANE

1000 hertz0dBm test tonefrom Platform Card

Platform Card

Flexi-Voice Plus Card

T1 Network

Dual OCU-DP Card(single Channel)

LIU

4-WireDriver

4-WireReceiver

DSU/CSU

Test Equipment

DriverLogic

ReceiverLogic

ToChan loopback

66 E-Block

34 GDC 086R603-001-04

Page 39: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

tic ed Card, k, the

ToNet Loopback

Use external test equipment at the Platform Card NETWORK front panel jack to generate and detect the test pattern. Select ToNet on the Flexi-Voice Plus Four-Wire Data Channel Diagnosscreen. The front panel LED corresponding to the channel performing the loopback, lights rindicating the ToNet loopback is engaged. This loopback verifies the integrity of the Platform LIU, backplane, Flexi-Voice Plus basecard, and the option card’s channel. During the loopbacchannel is disconnected from its four-wire loop and external DSU/CSU.

Figure 18 Manager-initiated - To Net Loopback

BACKPLANE

1000 hertz0dBm test tonefrom Platform Card

Platform Card

Flexi-Voice Plus Card

T1 Network

Dual OCU-DP Card(single Channel)

LIU

4-WireDriver

4-WireReceiver

DSU/CSU

Test Equipment

DriverLogic

ReceiverLogic

DTE

ToNet loopback

66 E-Block

GDC 086R603-001-04 35

Page 40: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

es an four-

CSU Loopback

Use external test equipment at the Platform Card NETWORK front panel jack to generate and detect the test pattern. Select CSU-MGR on the Flexi-Voice Plus Four-Wire Data Channel Diagnostic screen. This loopback reverses the sealing current on the 4-wire loop which placexternal DSU/CSU into CSU loopback. This network loopback tests through the channel, thewire loop and the DSU/CSU front end.

Figure 19 Manager-initiated CSU Loopback

BACKPLANE

1000 hertz0dBm test tonefrom Platform Card

Platform Card

Flexi-Voice Plus Card

Dual OCU-DP Card(single Channel)

LIU

4-WireDriver

4-WireReceiver

DSU/CSU

DriverLogic

ReceiverLogic

DTE

66 E-Block

OCU-DP Reversing Sealing Current

4-wire loop

Test CenterTest Equipment

STC

36 GDC 086R603-001-04

Page 41: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

C) for cept 64

f the h the four-

network-initiated Loopbacks

The Dual OCU-DP option card supports inband commands from the Serving Test Center (STeach channel. DDS network non-latching loopback codes are supported at all data rates exkbps. DDS network latching loopback codes are supported at all data rates.

Non-Latching: OCU Loopback

The Dual OCU-DP responds to the OCU loopback code by performing a bipolar loopback oDDS signal as in the Manager-initiated ToNet Loopback. This network loopback tests througchannel performing the loopback. During the loopback, the channel is disconnected from itswire loop and external DSU/CSU.

Figure 20 network-initiated - Non-Latching OCU Loopback

BACKPLANE

1000 hertz0dBm test tonefrom Platform Card

Platform Card

Flexi-Voice Plus Card

Dual OCU-DP Card(single Channel)

LIU

4-WireDriver

4-WireReceiver

DSU/CSU

DriverLogic

ReceiverLogic

DTE

Test CenterTest Equipment

STC

66 E-Block

GDC 086R603-001-04 37

Page 42: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

the 4-sts

Non-Latching: CSU Loopback

The Dual OCU-DP responds to the CSU loopback code by reversing the sealing current onwire loop which places an external DSU/CSU into CSU loopback. This network loopback tethrough the channel, the four-wire loop and the DSU/CSU front end.

The external DSU/CSU must support DDS CSU loopback.

Figure 21 network-initiated - Non-Latching CSU Loopback

BACKPLANE

1000 hertz0dBm test tonefrom Platform Card

Platform Card

Flexi-Voice Plus Card

Dual OCU-DP Card(single Channel)

LIU

4-WireDriver

4-WireReceiver

DSU/CSU

DriverLogic

ReceiverLogic

DTE

Test CenterTest Equipment

STC

OCU-DP ReversingSealing Current

4-wire loop

66 E-Block

38 GDC 086R603-001-04

Page 43: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

control to a ack e four-

Non-Latching: DSU Loopback

For standard DDS, the Dual OCU-DP responds to the DSU loopback code and transmits the code by inserting bipolar violations into the 4-wire loop which puts the external DSU/CSU inDSU loopback. For DDS with secondary channel, the Dual OCU-DP passes the DSU loopbcode transparently through the channel. This network loopback tests through the channel, thwire loop and the DSU/CSU.

The external DSU/CSU must support the DDS DSU loopback.

Figure 22 network-initiated - Non-Latching DSU Loopback

BACKPLANE

1000 hertz0dBm test tonefrom Platform Card

Platform Card

Flexi-Voice Plus Card

Dual OCU-DP Card(single Channel)

LIU

4-WireDriver

4-WireReceiver

DSU/CSU

DriverLogic

ReceiverLogic

DTE

Test CenterTest Equipment

STC

66 E-Block

GDC 086R603-001-04 39

Page 44: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

Latching: OCU Loopback (Refer to Non-Latching: OCU Loopback)

Figure 23 network-initiated - Latching OCU Loopback

BACKPLANE

1000 hertz0dBm test tonefrom Platform Card

Platform Card

Flexi-Voice Plus Card

Dual OCU-DP Card(single Channel)

LIU

4-WireDriver

4-WireReceiver

DSU/CSU

DriverLogic

ReceiverLogic

DTE

Test CenterTest Equipment

STC

66 E-Block

40 GDC 086R603-001-04

Page 45: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

Latching: CSU Loopback (Refer to Non-Latching: CSU Loopback)

Figure 24 network-initiated - Latching CSU Loopback

BACKPLANE

1000 hertz0dBm test tonefrom Platform Card

Platform Card

Flexi-Voice Plus Card

Dual OCU-DP Card(single Channel)

LIU

4-WireDriver

4-WireReceiver

DSU/CSU

DriverLogic

ReceiverLogic

DTE

Test CenterTest Equipment

STC

OCU-DP ReversingSealing Current

66 E-Block

GDC 086R603-001-04 41

Page 46: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

etwork

Latching: DSU Loopback

The Dual OCU-DP passes the DSU loopback code transparently through the channel. This nloopback tests through the channel, the four-wire loop and the DSU/CSU.

The external DSU/CSU must support the DDS DSU loopback.

Figure 25 network-initiated - Latching CSU Loopback

BACKPLANE

1000 hertz0dBm test tonefrom Platform Card

Platform Card

Flexi-Voice Plus Card

Dual OCU-DP Card(single Channel)

LIU

4-WireDriver

4-WireReceiver

DSU/CSU

DriverLogic

ReceiverLogic

DTE

Test CenterTest Equipment

STC

OCU-DP Passes DSU LoopbackCode Transparently

66 E-Block

42 GDC 086R603-001-04

Page 47: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

and

urable

ta

eive octet ive

four-tion

ipolar d by

with

Dual G.703/64k Option CardCompatibility - This option card requires Flexi-Voice Plus Card firmware revision D- or later, Platform Card firmware revision E- or later.

The Dual G.703/64k option card (Figure 26) provides a four-wire interface to a DTE. It is compatible with G.703 64k co-directional interfaces. Each card has two independently config64 kbps data channels which may be assigned to any unused timeslot on LIU A or LIU B.

Figure 26 Dual G.703/64k Option Card

Application Information

G.703/64k is fully compatible with both T1 and E1 networks. Channels may be assigned totimeslots in the ranges 1-24 for T1 and 1-31 for E1.

As shown in Figure 27, the Dual G.703/64k option card distributes data on a 4-wire loop to daterminal equipment with a G.703 interface.

The Dual G.703/64k option card co-directional interface consists of a transmit pair and a recpair. Each pair carries a bipolar signal which conveys 64 kbps data, 64 kHz timing, and 8 kHztiming. Data and timing on the transmit pair flow in the same direction. Likewise, on the recepair, data and timing flow in the same direction. Hence the term co-directional interface.

The 8 kHz octet timing is used to maintain byte alignment. The octet timing is conveyed on thewire interface during the last bit of the byte as a bipolar violation. Therefore, the bipolar violasignifies the end of a byte. In the transmit direction (towards the network), the first bit after a bviolation is transmitted as the first bit in the timeslot and the last bit in the timeslot is indicatea bipolar violation. In the receive direction, the last bit of the timeslot is indicated to the DTEa bipolar violation.

Note Do not connect the Dual G.703/64k option card to lines that go outside the building. It is intended for connection to on-premise equipment only.

..........

..

.

....

Key

Dual G.703/64k Option Card086P055-001MP6360/G.703-1

..........

..

.

....

..........

..

.

....

..........

..

.

....

GDC 086R603-001-04 43

Page 48: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

f

all

h up to ce at

nnel. ata

lways e four-

ing. -wire

The Dual G.703/64k option card will always provide receive octet timing toward the DTE. Itransmit octet timing is not provided by the DTE, the Dual G.703/64k option card will pick anarbitrary bit with which to maintain byte alignment.

The Dual G.703/64k option card supports transmission of the Alarm Indication Signal (AIS -ones).

AIS is transmitted toward the DTE:

• During a loopback toward the network.

• When the Platform Card is in an alarm condition.

AIS is transmitted toward the network:

• When there is no signal present at the four-wire interface.

The Dual G.703/64k option card can accurately recover a standard G.703/64 kbps signal wit6 dB of loss (1600 feet with 26 gauge wire). Loss of signal is declared on the four-wire interfa11 dB of loss or higher.

Figure 27 Typical G.703/64k Application

Busy/Idle Indication

The Busy or Idle state of the G.703/64k channel is indicated on the front panel LED for that chaThere is no indication of the Busy or Idle state of the channel on the Flexi-Voice Four-Wire DMonitor screen.

Since the Dual G.703/64k option card is transparent to the data application, the channel is aassumed to be busy once it is configured and operating normally (i.e. no loss of signal from thwire interface). Otherwise, the channel is idle.

Timing

The external DTE must be looped timed (synchronized) to the Metroplex™ 6000 system timThe DTE does this by deriving its transmit timing from the receive signal present at the fourinterface.

Flexi-Voice

Channels 3 & 4

Dual G.703/64kChannels 1 & 2

Channels 5 & 6

Dual G.703/64k

Dual G.703/64k

4-WireLoop G.703

Customer Premises

Plus Basecard

Network

T, R transmitT1, R1 receive

Loop Timing

DTE

Metroplex™ 6000

44 GDC 086R603-001-04

Page 49: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

or

to the

to the

Diagnostics

Figure 28 through Figure 29 illustrate loopback tests that you may perform from the manager network.

Manager-Initiated

ToChan Loopback

Use external test equipment to generate and detect the test pattern. Select ToChan on the Flexi-Voice Plus Four-Wire Data Channel Diagnostic screen. The front panel LED corresponding channel performing the loopback lights red indicating the ToChan loopback is engaged.

This loopback test verifies the integrity of the option card and the cables. The transmit data network is marked.

Figure 28 Manager-initiated - ToChan Loopback

BACKPLANE

1000 hertz0dBm test tonefrom Platform Card

Platform Card

Flexi-Voice Plus Card

Network

Dual G.703/64k Card(single Channel)

LIU

4-WireDriver

4-WireReceiver

Test Equipment

DriverLogic

ReceiverLogic

ToChan loopback

66 E-Block

GDC 086R603-001-04 45

Page 50: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

tic ed Card, k, the

ual on

ToNet Loopback

Use external test equipment at the Platform Card NETWORK front panel jack to generate and detect the test pattern. Select ToNet on the Flexi-Voice Plus Four-Wire Data Channel Diagnosscreen. The front panel LED corresponding to the channel performing the loopback, lights rindicating the ToNet loopback is engaged. This loopback verifies the integrity of the Platform LIU, backplane, Flexi-Voice Plus basecard, and the option card’s channel. During the loopbacreceive data to the DTE is marked.

Figure 29 Manager-initiated - To Net Loopback

Wiring Diagram

Figure 30 shows examples of wiring for a Dual 4W E&M option card, a Dual TB card and a DOB card. Figure 31 shows an example of wiring for a Dual OCU-DP and Dual G.703/64k opticards.

BACKPLANE

1000 hertz0dBm test tonefrom Platform Card

Platform Card

Flexi-Voice Plus Card

Network

Dual G.703/64k Card(single Channel)

LIU

4-WireDriver

4-WireReceiver

Test Equipment

DriverLogic

ReceiverLogic

DTE

ToNet loopback

66 E-Block

46 GDC 086R603-001-04

Page 51: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

Figure 30 Wiring for Voice Option Cards

66 E-Block

Cable No. 830-002S01150-pin connector to 50-pin connector

Flexi-Voice Plus Basecard086P040-001

Dual 4W E&MChannels 5 & 6

Dual TB

Channels 3 & 4(Terminate Battery)

Dual OB(Originate Battery)Channels 1 & 2

T 42 46

R 17 21

TI 43 47

RI 18 22

E 44 48

M 45 49

SG 19 23

SB 20 24

Dual 4-W

CH-5 & CH-6

Chan 5

Chan 6

T 34 38

R 9 13

E&M

T 26 30

R 1 5

Dual TB (FXO)CH-3 & CH-4

Dual OB (FXS)CH-1 & CH-2

Chan 3 Chan 4

Chan 1 Chan 2

Desig. Pin Nos.

GDC 086R603-001-04 47

Page 52: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

Figure 31 Wiring for Four-Wire Data Channel Option Cards

Cable No. 830-002S01150-pin connector to 50-pin connector

Flexi-Voice Plus Basecard086P040-001

Channels 3 & 4

Dual G.703/64k

Channels 1 & 2

Dual OCU-DP

CH-5 & CH-6

Desig. Pin Nos.

Channels 5 & 6

DSU/CSUDTE

Dual OCU-DP

Dual OCU-DP

Chan 5 Chan 6

TRT1R1

43184217

Dual OCU-DP

CH-3 & CH-4

TRT1R1

3510349

Chan 3 Chan 4

47224621

39143813

Dual G.703/64k

CH-1 & CH-2

TRT1R1

261272

Chan 1 Chan 2

305316

66 E-Block

48 GDC 086R603-001-04

Page 53: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

Plus

Pinouts Figure 32 illustrates the cable and describes the pinout of the J1 connector of the Flexi-VoiceCard.

Pin 1 Contact Side

830-002S011 (10ft), S008 (25ft), S012 (50ft) 50-pin (M) to 50-pin (M) Amphenol Cable

NOTE:

T, R = 4-wire transmit to network, or 2-wire transmit/receive

T1, R1 = 4-wire receive from network

E = receive signaling from network

M = transmit signaling to network

GDC 086R603-001-04 49

Page 54: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

Figure 32 Flexi-Voice Plus Cable and J1 Pinout

Pin Color Code

Band/Stripe

209-036-020

Harmonica (RJ1CX)

Channel 4W E&M

(RJ2HX)

4W TO OB TB OCU-DP

(RJ48T)

G.703/64k

26 WHT/BLU 5 1 T T T T T1 T

1 BLU/WHT 4 1 R R R R R1 R

27 WHT/ORG 1 1 T1 T1 - - T T1

2 ORG/WHT 2 1 R1 R1 - - R R1

28 WHT/GRN 3 1 E - - - - -

3 GRN/WHT 6 1 SG - - - - -

29 WHT/BRN 7 1 M - - - - -

4 BRN/WHT 8 1 SB - - - - -

30 WHT/SLT 5 2 T T T T T1 T

5 SLT/WHT 4 2 R R R R R1 R

31 RED/BLU 1 2 T1 T1 - - T T1

6 BLU/RED 2 2 R1 R1 - - R R1

32 RED/ORG 3 2 E - - - - -

7 ORG/RED 6 2 SG - - - - -

33 RED/GRN 7 2 M - - - - -

8 GRN/RED 8 2 SB - - - - -

34 RED/BRN 5 3 T T T T T1 T

9 BRN/RED 4 3 R R R R R1 R

35 RED/SLT 1 3 T1 T1 - - T T1

10 SLT/RED 2 3 R1 R1 - - R R1

36 BLK/BLU 3 3 E - - - - -

11 BLU/BLK 6 3 SG - - - - -

37 BLK/ORG 7 3 M - - - - -

12 ORG/BLK 8 3 SB - - - - -

38 BLK/GRN 5 4 T T T T T1 T

13 GRN/BLK 4 4 R R R R R1 R

39 BLK/BRN 1 4 T1 T1 - - T T1

14 BRN/BLK 2 4 R1 R1 - - R R1

40 BLK/SLT 3 4 E - - - - -

15 SLT/BLK 6 4 SG - - - - -

41 YEL/BLU 7 4 M - - - - -

16 BLU/YEL 8 4 SB - - - - -

42 YEL/ORG 5 5 T T T T T1 T

17 ORG/YEL 4 5 R R R R R1 R

43 YEL/GRN 1 5 T1 T1 - - T T1

18 GRN/YEL 2 5 R1 R1 - - R R1

44 YEL/BRN 3 5 E - - - - -

19 BRN/YEL 6 5 SG - - - - -

45 YEL/SLT 7 5 M - - - - -

20 SLT/YEL 8 5 SB - - - - -

46 VIO/BLU 5 6 T T T T T1 T

21 BLU/VIO 4 6 R R R R R1 R

47 VIO/ORG 1 6 T1 T1 - - T T1

22 ORG/VIO 2 6 R1 R1 - - R R1

48 VIO/GRN 3 6 E - - - - -

23 GRN/VIO 6 6 SG - - - - -

49 VIO/BRN 7 6 M - - - - -

24 BRN/VIO 8 6 SB - - - - -

50 VIO/SLT not used not used - - -

25 SLT/VIO not used not used - - -

50 GDC 086R603-001-04

Page 55: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

Specifications and Parts List

The specifications and parts list for the Flexi-Voice Card are found in Table 2.

Table 2 Specifications and Parts List

PhysicalCard AssemblyHeight

Width

Depth

Weight

10.4 in. (264 mm)

0.85 in. (22 mm)

10.75 in. (273 mm)

1 lb. 2oz (0.54 kg)

TemperatureOperating

Non-operating

HumidityOperating

AltitudeOperating

Non-operating

0 to 50°C (32 to 122°F) (derate by 1 C/1000 ft above sea level)

-40 to 85°C (-40 to 185°F)

5% to 95%, without condensation

0 to 10,000 ft (0 to 3,048 m)

0 to 40,000 ft (0 to 12,192 m)

ElectricalPower Requirements Power may be either 22 VAC, -24 VDC, or -48 VDC

Fusing One 3.0A, 125V, SB (GDC Part No. 215-311W300)

Dual OB Option CardSignaling types supported Loop and ground start with and without loop conversion, PLAR,

DPO

Subscriber interface Foreign Exchange Station (FXS), Dial Pulse Originate (DPO)

Battery feed Internal -24 VDC Talk Battery

Internal -52 VDC Standby Battery

Loop current 25 mA

Maximum loop resistance 575 ohms (including 430 for telephone) at 25mA

750 ohms (includes 430 ohms for telephone) at 20mA

Maximum loop length 2,500 feet of 24 AWG at 25ma

5,600 feet of 24 AWG at 20mA

Ringer feed Internal 56 Vrms 20 Hertz

Ringer drive capability 2.0 REN (2 - 2500 type phones)

Ringer cadence 2 seconds On, 4 seconds Off or transparent (FXO to FXS)

Ringback tone -15dBm0 440, 480 hertz tone, 2 seconds on, 4 seconds off

Impedance 600 ohms

Return loss >12 dB, 200-3400 Hz

ERL >25 dB

SRL >25 dB

Maximum input level +3 dBm

Maximum output level -3 dBm

Longitudinal Balance > 60 dB, 200-1000Hz; > 40 dB, 1500-4000 Hz. Meets FCC Part 68

Transmit Frequency Response -2.0, +0.2 dB from 200-3400 Hz; referenced to 1000 Hz 0 dB

Receive Frequency Response -2.0, +0.2 dB from 200-3400 Hz; referenced to 1000 Hz 0 dB

GDC 086R603-001-04 51

Page 56: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

Idle Channel Noise < 20 dBrnC0

Ring Ground Detection Detects up to 2000 ohms

Transmit TLP Values Default 1: +3.0 dB (Range from +9.0 dB to -3.0 dB)

Default 2: +3.0 dB (Range from +9.0 dB to -3.0 dB)

Default 3: 0.0 dB (Range from +6.0 dB to -6.0 dB)

Receive TLP Values Default 1: -9.0 dB (Range from -3.0 dB to -15.0 dB)

Default 2: -3.0 dB (Range from +3.0 dB to -9.0 dB)

Default 3: -6.0 dB (Range from 0.0 dB to -12.0 dB)

Dual TB Option CardSignaling types supported Loop Start and ground start, DPT

Exchange interface Foreign Exchange Office (FXO), Dial Pulse Terminate (DPT)

Max. DC impedance 300 ohms

Max Loop current 80 mA

Ringing detector FCC Part 68 Type B ringer

Registration Meets FCC Part 68, UL1459

Impedance 600 or 900 ohms hardware selectable

Return loss >12 dB, 200-3400 Hz

ERL >25 dB

SRL >25 dB

Maximum input level +3 dBm

Maximum output level -3 dBm

Longitudinal Balance > 60 dB, 200-1000Hz; > 40 dB, 1500-4000 Hz. Meets FCC Part 68

Transmit Fequency Response -2.0, +0.2 dB from 200-3400 Hz; referenced to 1000 Hz 0 dB

Receive Frequency Response -2.0, +0.2 dB from 200-3400 Hz; referenced to 1000 Hz 0 dB

Idle Channel Noise < 20 dBrnC0

Peak-to-Average Ratio (P/AR) > 94

TransHybrid Loss 600 ohm >13 dB, 500-2500 Hz; > 18 dB, 2500-3500 Hz

TransHybrid Loss 900 ohm >12 dB, 500-2500 Hz; > 14 dB, 2500-3500 Hz

Gain Tracking (1010 Hz 0dBm0)

±0.5 dB from -37 to +3.0 dBm0; ±1.0 dB from -50 to -37 dBm0

Signal-to-Noise >33dB, 0 to -30dBm0; >27dB, -40dBm0; >22dB, -45dBm0

Transmit TLP Values Default 1: +3.0 dB (Range from +9.0 dB to -3.0 dB)

Default 2: 0.0 dB (Range from +6.0 dB to -6.0 dB)

Receive TLP Values Default 1: -3.0 dB (Range from -1.0 dB to -9.0 dB)

Default 2: -9.0 dB (Range from -3.0 dB to -15.0 dB)

Dual 4-W E&M Option CardSignaling types supported Type 1, 2, 3, and 5

Interface type "B" side E&M

M-lead current detector 2.4 mA

E-lead driver 250 mA max

Impedance 600 ohms

Maximum input level 0 dBm

Maximum output level +7 dBm

Return loss > 12 dB, 200-3400 Hz

Longitudinal Balance > 46 dB, 300-2400Hz; > 41 dB, 2400-3400 Hz

Transmit Fequency Response +1.0, -0.2 dB from 300-3000 Hz; referenced to 1000 Hz 0 dB

Table 2 Specifications and Parts List (Continued)

52 GDC 086R603-001-04

Page 57: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

Receive Frequency Response +0.2. -0.2 dB from 300-3000 Hz; referenced to 1000 Hz 0 dB

Idle Channel Noise < 20 dBrnC0

Transmit TLP Values Default 1: 0.0 dB (Range from +1.5 dB to -8.0 dB)

Default 2: -16.0 dB (Range from -8.0 dB to -17.5 dB)

Receive TLP Values Default 1: 0.0 dB (Range from +1.5 dB to -8.0 dB)

Default 2: +7.0 dB (Range from +8.5 dB to -1.0 dB)

Dual 4-W TO Option CardImpedance 600 ohms

Maximum input level 0 dBm

Maximum output level +7 dBm

Return loss > 12 dB, 200-3400 Hz

Longitudinal Balance > 46 dB, 300-2400Hz; > 41 dB, 2400-3400 Hz

Transmit Fequency Response +1.0, -0.2 dB from 300-3000 Hz; referenced to 1000 Hz 0 dB

Receive Frequency Response +0.2, -0.2 dB from 300-3000 Hz; referenced to 1000 Hz 0 dB

Idle Channel Noise < 20 dBrnC0

Transmit TLP Values Default 1: +10.0 dB (Range from +16.0 dB to +6.5 dB)

Default 2: 0.0 dB (Range from +6.5 dB to -3.0 dB)

Receive TLP Values Default 1: -3.0 dB (Range from -1.5 dB to -11.0 dB)

Default 2: 0.0 dB (Range from +8.0 dB to -1.5 dB)

Dual OCU-DP Option CardCommunications Line DDS or 4-wire, non-loaded metallic lines (19-26 gauge)

Terminating Impedance 135 ohms

Data Rate 2.4, 4.8, 9.6, 19.2, 56, 64 kbps

(synchronous)

Output Power +6 dBm, maximum at 2.4, 4.8, 19.2, 56, and 64 kbps

0 dBm, maximum at 9.6 kbps

RangeLine Rate Mileage with 26 ga. cable

2.4 kbps 10.5 miles

2.4 kbps (DDSII) 8.9 miles

4.8 kbps 8.3 miles

4.8 kbps (DDSII) 7.2 miles

9.6 kbps 6.4 miles

9.6 kbps (DDSII) 5.4 miles

19.2 kbps 5.2 miles

19.2 kbps (DDSII) 4.8 miles

56 kbps 3.3 miles

56 kbps (DDSII) 3.0 miles

64 kbps 3.0 miles

DC Sealing CurrentLoop Length DC Current

3 miles 7.4 mA 1400 ohm termination

6.7 mA 1750 ohm termination

10.5 miles 4.7 mA 1400 ohm termination

4.4 mA 1750 ohm termination

Dual G.703/64k Option card

Table 2 Specifications and Parts List (Continued)

GDC 086R603-001-04 53

Page 58: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

Communications Line 4-wire, non-loaded metallic lines (19-26 gauge)

Terminating Impedance 120 ohms

Data Rate 64 kbps synchronous

Output Power +3dBm, maximum

Range 1600 feet (26 ga. cable) max.

Parts ListFlexi-Voice Plus Basecard 086P040-001

Dual OB Option card (MP6360/OB-1)

086P050-001

Dual TB Option Card (MP6360/TB-1)

086P051-001

Dual 4W E&M Option Card (MP6360/EM-1)

086P052-001

Dual 4W TO Option Card (MP6360/4W TO-1)

086P053-001

Dual OCU-DP Option Card (MP6360/OCU-DP1)

086P054-001

Dual G.703/64k Option Card

(MP6360/G703-1)

086P055-001

Cables50-pin Amphenol (male) to 50-pin Amphenol (male) shielded

830-002S011 (10 ft.)

830-002S008 (25 ft.)

830-002S012 (50 ft.)

50-pin Amphenol (male) to 50-pin Amphenol (female) shielded

830-002S016 (5 ft.)

830-002S007 (25 ft.)

50-pin Amphenol (male) to six 8-position modular jacks,

Harmonica Adapter pinout

209-036-020

66M Punch-down block to 50-pin female Amphenol connector

SYS=326P032

Table 2 Specifications and Parts List (Continued)

54 GDC 086R603-001-04

Page 59: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice PlusIndex

A

Application InformationDual 4W E&M Option Card 21Dual 4W TO Option Card 28Dual G.703/64k Option Card 43Dual OCU-DP Option Card 32Dual TB Option Card 15

B

Battery Feed 8Busy/Idle Indication 8

Dual 4W E&M option card 21Dual G.703/64k Option Card 44Dual OCU-DP Option Card 32Dual TB Option Card 15

C

Caller-ID 11Card Self-test 12, 18, 24, 28, 33Compatibility 3Configuration

Dual OCU-DP 33Flexi-Voice Plus 1

CSU Loopback 36

D

DC Sealing Current 33Diagnostics

Dual 4W E&M Option Card 24Dual 4W TO Option card 28Dual G.703/64k Option Card 45Dual OCU-DP Option Card 33Dual TB Option Card 18Flexi-Voice Plus 2

Digital Milliwatt 13, 19, 25, 29DPO Loop Start 11DPT Loop Start 17Dual 4W E&M Option Card 20Dual 4W TO Option Card 27Dual G.703/64k Option Card 43Dual OB (FXS) Option Card 7Dual OCU-DP Option Card 31Dual TB (FXO) Option Card 15

E

E&M Signaling 21

F

Flexi-Voice Plus 1Flow Diagram - FXS Octet Card 12, 18Force Busy Next Idle Condition 13, 19, 25Forced Busy Condition 13, 19, 25Forced Idle Condition 14, 20, 26Front Panel Connector Retaining Hardware 6Front Panel Indicators and Connections 3

G

Ground Start With E&M Conversion 10

I

Installation of Basecard 5Installation of Option Cards 4

L

LatchingCSU Loopback 41DSU Loopback 42OCU Loopback 40

Latching Loopback Enable or Disable 33Loop Start With E&M Conversion 10Loopback Test 12, 18, 24Loopback With Digital Milliwatt 13, 19, 25, 29

M

Manager Initiated 45Manager Initiated Loopbacks 34Manager-Initiated Loopback 28Manual Revision History 2

N

Network Initiated Loopbacks 37Network-Initiated Loopback 30Non-Latching

CSU Loopback 38DSU Loopback 39OCU Loopback 37

P

Pinouts 49PLAR Loop Start 11

GDC 086R603-001-04 Index-1

Page 60: Metroplex 6000 - General DataComm - Home · Metroplex™ 6000 General DataComm. ... Flexi-Voice Plus Card ... • Conditions voice and data channels in response to network alarms

Flexi-Voice Plus Installation & Operation Manual

Index (Cont’d)

S

Specifications and Parts List 51Standard Ground Start 9

Dual TB Option Card 16Standard Loop Start 9

Dual TB Option Card 16Status 2

T

TimingDual G.703/64k Option Card 44Dual OCU-DP Option Card 33

TLP Values 8Dual 4W E&M Option Card 21Dual 4W TO Option Card 28Dual TB Option Card 16

ToChan LoopbackDual OCU-DP Option Card 34

ToNet LoopbackDual G.703/64k Option card 46Dual OCU-DP Option card 35

W

Wiring Diagram 46

Z

ZCS (Zero Code Suppression) Enable or Disable 33

Index-2 GDC 086R603-001-04