metode optice pentru detectia alimentelor iradiate cu radiatii ionizante
DESCRIPTION
METODE OPTICE PENTRU DETECTIA ALIMENTELOR IRADIATE CU RADIATII IONIZANTE. Dr. Mihail SECU. Institutul National de Cercetare si Dezvoltare pentru Fizica Materialelor (INCDFM) Bucuresti-Magurele. Cuprins. 1. Principiile de baza ale termoluminescentei si luminescentei stimulate optic - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: METODE OPTICE PENTRU DETECTIA ALIMENTELOR IRADIATE CU RADIATII IONIZANTE](https://reader033.vdocuments.site/reader033/viewer/2022061614/56815931550346895dc6650e/html5/thumbnails/1.jpg)
METODE OPTICE PENTRU DETECTIA ALIMENTELOR IRADIATE CU RADIATII IONIZANTE
Institutul National de Cercetare si Dezvoltare pentru Fizica Materialelor (INCDFM) Bucuresti-Magurele
Dr. Mihail SECU
![Page 2: METODE OPTICE PENTRU DETECTIA ALIMENTELOR IRADIATE CU RADIATII IONIZANTE](https://reader033.vdocuments.site/reader033/viewer/2022061614/56815931550346895dc6650e/html5/thumbnails/2.jpg)
Cuprins
1. Principiile de baza ale termoluminescentei si luminescentei stimulate optic 1.1. Echipamente de masura ale TL si OSL.
2. Termoluminescenta (TL) ca metoda de detectie a alimentelor irradiate cu radiatii ionizante2.1. Metodologia de lucru.2.2. Tehnica de masura a TL. 2.3. Rezultate experimentale si interpretarea lor.
3. Luminescenta stimulata optic (OSL) ca metoda de detectie a alimentelor iradiate cu radiatii ionizante3.1. Metodologia de lucru. 3.2. Tehnica de masura a OSL.3.3. Rezultate experimentale si interpretarea lor.3.4. Efectuarea de masuratori OSL comparative pe o instalatie RISØ.
4. Concluzii.
![Page 3: METODE OPTICE PENTRU DETECTIA ALIMENTELOR IRADIATE CU RADIATII IONIZANTE](https://reader033.vdocuments.site/reader033/viewer/2022061614/56815931550346895dc6650e/html5/thumbnails/3.jpg)
1. Principiile de baza ale termoluminescentei (TL) si luminescentei stimulate optic(OSL)
Termoluminescenta (TL) siLuminescenta stimulataoptic(OSL) sunt tehniciexperimentale ce masoaracantitatea de energie stocatade catre reteaua materialuluiin cursul iradierii acestuia
Aplicatii: studiul defectelor de iradiere, dozimetria de radiatii, datarea geologica si arheologica, detectia alimentelor iradiate.
![Page 4: METODE OPTICE PENTRU DETECTIA ALIMENTELOR IRADIATE CU RADIATII IONIZANTE](https://reader033.vdocuments.site/reader033/viewer/2022061614/56815931550346895dc6650e/html5/thumbnails/4.jpg)
1. Echipamentele de masura ale TL si OSL tip RISØ
Stimulare cu LED-uri:in “albastru” la 470nm sau in “infrarosu” la 875nm
Domeniul de temperatura: 20-700C Rata de incalzire: 0.1-30 K/s,
![Page 5: METODE OPTICE PENTRU DETECTIA ALIMENTELOR IRADIATE CU RADIATII IONIZANTE](https://reader033.vdocuments.site/reader033/viewer/2022061614/56815931550346895dc6650e/html5/thumbnails/5.jpg)
2.1. Metodologia de lucru pentru detectia alimentelor iradiate cu ajutorul TL.
1. Separarea mineralelorEtapa de preconcentrare a mineralelor- desprinderea mineralelor aderente si cresterea concentratiei lor intr-o solutie apoasa prin: ultrasonare, cernere, decantare, centrifugareEtapa de separare prin densitate- separarea si sedimentarea in solutie si centrifugareEliminarea carbonatilor aderenti prin dizolvare cu acid si neutralizarea lor.Fixarea pe discurile de inox.
2. Efectuarea masuratorilor de TL pe probe inainte si dupa iradierea lor cu o doza cunoscuta (1kGy).
3. Prelucrarea datelor si interpretarea rezultatelor.
![Page 6: METODE OPTICE PENTRU DETECTIA ALIMENTELOR IRADIATE CU RADIATII IONIZANTE](https://reader033.vdocuments.site/reader033/viewer/2022061614/56815931550346895dc6650e/html5/thumbnails/6.jpg)
2.2. Tehnica de masura folosita pentru inregistrarea termoluminescentei
H= element incalzitor ; CT=controlor de temperatura ; FM=fotomultiplicatorS1= sursa alimentare a FM ; A=amplificator ; I=interfata ; PC=calculator
![Page 7: METODE OPTICE PENTRU DETECTIA ALIMENTELOR IRADIATE CU RADIATII IONIZANTE](https://reader033.vdocuments.site/reader033/viewer/2022061614/56815931550346895dc6650e/html5/thumbnails/7.jpg)
2.3. Efectuarea masuratorilor de TL pe probe inainte si dupa iradierea lor cu 1kGy. Rezultate experimentale
Scortisoara
Dafin
Extragere minerale masurare TL(1) iradiere 1kGy
masurare TL(2) raport semnale TL(1)/TL(2) iradiata sau neiradiata
![Page 8: METODE OPTICE PENTRU DETECTIA ALIMENTELOR IRADIATE CU RADIATII IONIZANTE](https://reader033.vdocuments.site/reader033/viewer/2022061614/56815931550346895dc6650e/html5/thumbnails/8.jpg)
Efectuarea masuratorilor de TL pe probe inainte si dupa iradierea lor cu 1kGy. Rezultate experimentale
Fasole
Boia
![Page 9: METODE OPTICE PENTRU DETECTIA ALIMENTELOR IRADIATE CU RADIATII IONIZANTE](https://reader033.vdocuments.site/reader033/viewer/2022061614/56815931550346895dc6650e/html5/thumbnails/9.jpg)
Interpretarea masuratorilor de termoluminescenta
Raport > 0.1 alimentul a fost iradiat
Raport < 0.1 alimentul nu a fost iradiat
![Page 10: METODE OPTICE PENTRU DETECTIA ALIMENTELOR IRADIATE CU RADIATII IONIZANTE](https://reader033.vdocuments.site/reader033/viewer/2022061614/56815931550346895dc6650e/html5/thumbnails/10.jpg)
3.1. Metodologia de lucru pentru detectia alimentelor iradiate cu ajutorul OSL.
1. Efectuarea masuratorilor de OSL pe probe inainte si dupa iradierea lor cu o doza cunoscuta (1kGy).
2. Prelucrarea datelor si interpretarea rezultatelor experimentale.
![Page 11: METODE OPTICE PENTRU DETECTIA ALIMENTELOR IRADIATE CU RADIATII IONIZANTE](https://reader033.vdocuments.site/reader033/viewer/2022061614/56815931550346895dc6650e/html5/thumbnails/11.jpg)
3.2. Tehnica de masura folosita pentru inregistrarea luminescentei stimulate optic
A=alimentator ; S=sursa de lumina ; F=filtru optic ; FO=fibra optica ; R=inel optic ; D=disc; P=proba; C=condensor de lumina ; CO=cutieoptica; FM= fotomultiplicator ; Acc=amplificator ; I=interfata ; PC= calculator ; HV= alimentator pentru FM
![Page 12: METODE OPTICE PENTRU DETECTIA ALIMENTELOR IRADIATE CU RADIATII IONIZANTE](https://reader033.vdocuments.site/reader033/viewer/2022061614/56815931550346895dc6650e/html5/thumbnails/12.jpg)
Efectuarea masuratorilor de OSL pe probe inainte si dupa iradierea lor cu o doza cunoscuta (1kGy). Rezultate experimentale
Scortisoara
Dafin
![Page 13: METODE OPTICE PENTRU DETECTIA ALIMENTELOR IRADIATE CU RADIATII IONIZANTE](https://reader033.vdocuments.site/reader033/viewer/2022061614/56815931550346895dc6650e/html5/thumbnails/13.jpg)
Efectuarea masuratorilor de OSL pe probe de dafin inainte si dupa iradierea lor cu o doza cunoscuta(1kGy)
Raport 0.9 alimentul a fost iradiat
Raport < 0.9 alimentul nu a fost iradiat
![Page 14: METODE OPTICE PENTRU DETECTIA ALIMENTELOR IRADIATE CU RADIATII IONIZANTE](https://reader033.vdocuments.site/reader033/viewer/2022061614/56815931550346895dc6650e/html5/thumbnails/14.jpg)
Efectuarea de masuratori OSL comparative pe o instalatie tip TL/OSL Reader tip RISØ
Imbunatatirea raportului semnal/zgomot !
TL/OSL Reader Risø
Echipament construit
![Page 15: METODE OPTICE PENTRU DETECTIA ALIMENTELOR IRADIATE CU RADIATII IONIZANTE](https://reader033.vdocuments.site/reader033/viewer/2022061614/56815931550346895dc6650e/html5/thumbnails/15.jpg)
5. Concluzii.
1. Masuratorile de termoluminescenta si luminescenta stimulata optic efectuate asupra unui esantion de produse de pe piata au aratat eficienta acestor metode in detectia alimentelor iradiate.
2. Termoluminescenta este o metoda laborioasa dar mult mai sigura decat luminescenta stimulata optic care este rapida dar mai nesigura.
2. Dintre alimentele studiate scortisoara, boia, graul si piperul sunt foarte probabil iradiate iar celelalte, dafin, patrunjel, cimbru, ceapa, fasole, orez, cartof nu sunt iradiate.
3. Concluziile celor doua metode prezentate privitoare la alimentele sunt consistente.
4. A fost construit un montaj dedicat masuratorilor de luminescenta stimulata optic ale catui performante pot fi imbunatatite.