meter pits and appurtenances - home | boston water and ... · meter pit details general notes....

7
ELEVATION PLAN INSTALLATION OF REMOTE READING DEVICES BY COMMISSION NOTE: Scale: Not To Scale Boston Water and Sewer Commission DETAIL NO. DATE: Location\Filename: V:\eng\ACAD_STD\Technical Details\M - Meter Details\M-02 - Meter Pit Details.dwg Plotted on: Tuesday, August 11, 2015 - 12:41 PM by Donohoe, William M-02a 980 HARRISON AVE., BOSTON, MA 02119 (617) 989-7000 www.bwsc.org METER PIT FOR UP TO 2-INCH METER Sept. 30, 2012

Upload: others

Post on 08-Sep-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Meter Pits and Appurtenances - Home | Boston Water and ... · meter pit details general notes. sept. 30, 2012. 1. details shown to accommodate two different size details shown to

ELEVATION

PLAN

INSTALLATION OF REMOTE READINGDEVICES BY COMMISSION

NOTE:

Scale: Not To Scale

Boston Water andSewer Commission

DETAIL NO.DATE:

Loca

tion\F

ilena

me: V

:\eng

\ACA

D_ST

D\Te

chnic

al De

tails\

M -

Meter

Deta

ils\M

-02 -

Mete

r Pit D

etails

.dwg

Plott

ed on

: Tue

sday

, Aug

ust 1

1, 20

15 -

12:41

PM

by D

onoh

oe, W

illiam

M-02a980 HARRISON AVE., BOSTON, MA 02119(617) 989-7000 www.bwsc.org

METER PIT FOR UP TO 2-INCH METER

Sept. 30, 2012

AutoCAD SHX Text
FINISHED GRADE
AutoCAD SHX Text
BOSTON WATER AND SEWER COMMISSION STANDARD METER PIT COVER (SEE GENERAL NOTE NO.6 ON DETAIL NO M-02g)
AutoCAD SHX Text
GRADE RINGS
AutoCAD SHX Text
6" x 12" x 30" CONCRETE PAD
AutoCAD SHX Text
METER
AutoCAD SHX Text
FLOW
AutoCAD SHX Text
9" MASONRY OPENING
AutoCAD SHX Text
OF PIPE AND 9" MASONRY OPENING
AutoCAD SHX Text
FOOTING
AutoCAD SHX Text
CONCRETE SLAB
AutoCAD SHX Text
MASONRY FILLER
AutoCAD SHX Text
GATE VALVE(TYP.)
AutoCAD SHX Text
CONTRACTOR SHALL NOTIFY BWSC METER DEPT. TO DETERMINE IF METER CONDUIT MUST BE INSTALLED. IF REQUIRED THE CONTRACTOR SHALL SUPPLY THE WIRE AND INSTALL AS SPECIFIED.
Page 2: Meter Pits and Appurtenances - Home | Boston Water and ... · meter pit details general notes. sept. 30, 2012. 1. details shown to accommodate two different size details shown to

ELEVATION

PLAN

INSTALLATION OF REMOTE READINGDEVICES BY COMMISSION

NOTES:

Scale: Not To Scale

Boston Water andSewer Commission

DETAIL NO.DATE:

Loca

tion\F

ilena

me: V

:\eng

\ACA

D_ST

D\Te

chnic

al De

tails\

M -

Meter

Deta

ils\M

-02 -

Mete

r Pit D

etails

.dwg

Plott

ed on

: Tue

sday

, Aug

ust 1

1, 20

15 -

12:41

PM

by D

onoh

oe, W

illiam

M-02b980 HARRISON AVE., BOSTON, MA 02119(617) 989-7000 www.bwsc.org

METER PIT FOR 3, 4 AND 6-INCH

COMPOUND METERS July 15, 2015

AutoCAD SHX Text
COMPOUND METER w/2" TEST BALL VALVE BUILT INTO TOP OR SIDE OF METER
AutoCAD SHX Text
C
AutoCAD SHX Text
L
AutoCAD SHX Text
OF PIPE AND WALL OPENING
AutoCAD SHX Text
METER FLOW
AutoCAD SHX Text
INSTALL GRADE RINGS AS NECESSARY
AutoCAD SHX Text
2
AutoCAD SHX Text
ALL METERS MUST BE EQUIPPED WITH STRAINERS OF THE SAME MANUFACTURER AS THE METER
AutoCAD SHX Text
4
AutoCAD SHX Text
6" x 18" MECH. JT. TOMECH. JT. WALL PIPE THROUGH 12" OPENING
AutoCAD SHX Text
OF METER PIT
AutoCAD SHX Text
LIFTING HOLE (TYP. OF 4)
AutoCAD SHX Text
FLANGED TO PLAIN END ADAPTER (LENGTH TO FIT CONDITION)
AutoCAD SHX Text
OF METER PIT
AutoCAD SHX Text
FINISHED GRADE
AutoCAD SHX Text
BOSTON WATER AND SEWER COMMISSION STANDARD TYPE A-2 METER PIT
AutoCAD SHX Text
G FRAME AND COVER
AutoCAD SHX Text
1.BY-PASS METER CAN BE 1 SIZE SMALLER THAN BY-PASS METER CAN BE 1 SIZE SMALLER THAN MAIN METER. 2.ALL GATES TO BE TEFLON COATED. ALL GATES TO BE TEFLON COATED. 3.CONTRACTOR SHALL NOTIFY BWSC METER DEPT. CONTRACTOR SHALL NOTIFY BWSC METER DEPT. TO DETERMINE IF METER CONDUIT MUST BE INSTALLED. IF REQUIRED THE CONTRACTOR SHALL SUPPLY THE WIRE AND INSTALL AS SPECIFIED.
AutoCAD SHX Text
FLOW
AutoCAD SHX Text
FLOW
AutoCAD SHX Text
FLOW
AutoCAD SHX Text
FLOW
AutoCAD SHX Text
4 PIPE DIAMETERS BEFORE METER MIN.
AutoCAD SHX Text
COMPOUND METER w/2" TEST BALL VALVE BUILT INTO TOP OR SIDE OF METER
AutoCAD SHX Text
2 PIPE DIAMETERS AFTER METER MIN.
Page 3: Meter Pits and Appurtenances - Home | Boston Water and ... · meter pit details general notes. sept. 30, 2012. 1. details shown to accommodate two different size details shown to

ELEVATION

PLAN

NEPTUNEHP

TURBINE

INSTALLATION OF REMOTE READINGDEVICES BY COMMISSION

NOTES:

Scale: Not To Scale

Boston Water andSewer Commission

DETAIL NO.DATE:

Loca

tion\F

ilena

me: V

:\eng

\ACA

D_ST

D\Te

chnic

al De

tails\

M -

Meter

Deta

ils\M

-02 -

Mete

r Pit D

etails

.dwg

Plott

ed on

: Tue

sday

, Aug

ust 1

1, 20

15 -

12:41

PM

by D

onoh

oe, W

illiam

M-02c980 HARRISON AVE., BOSTON, MA 02119(617) 989-7000 www.bwsc.org

July 15, 2015

METER PIT FOR 3, 4, 6, 8 AND 10-INCH

TURBINE METERS

AutoCAD SHX Text
METER FLOW
AutoCAD SHX Text
2
AutoCAD SHX Text
OF PIPE AND WALL OPENING
AutoCAD SHX Text
4
AutoCAD SHX Text
C
AutoCAD SHX Text
L
AutoCAD SHX Text
2" METER TEST BALL VALVE
AutoCAD SHX Text
MECHANICAL TEE METER DIAMETER BY3"
AutoCAD SHX Text
6" x 18" MECH. JT. TOMECH. JT. WALL PIPE THROUGH 12" OPENING
AutoCAD SHX Text
OF METER PIT
AutoCAD SHX Text
FINISHED GRADE
AutoCAD SHX Text
BOSTON WATER AND SEWER COMMISSION STANDARD TYPE A-2 METER PIT
AutoCAD SHX Text
INSTALL GRADE RINGS AS NECESSARY
AutoCAD SHX Text
G FRAME AND COVER
AutoCAD SHX Text
LIFTING HOLE (TYP. OF 4)
AutoCAD SHX Text
FLANGED TO PLAIN END ADAPTER (LENGTH TO FIT CONDITION)
AutoCAD SHX Text
2 PIPE DIAMETERS AFTER METER MIN.
AutoCAD SHX Text
4 PIPE DIAMETERS BEFORE METER MIN.
AutoCAD SHX Text
FLOW
AutoCAD SHX Text
OF METER PIT
AutoCAD SHX Text
1.BY-PASS METER CAN BE 1 SIZE SMALLER THAN BY-PASS METER CAN BE 1 SIZE SMALLER THAN MAIN METER. 2.ALL GATES TO BE TEFLON COATED. ALL GATES TO BE TEFLON COATED. 3.CONTRACTOR SHALL NOTIFY BWSC METER DEPT. CONTRACTOR SHALL NOTIFY BWSC METER DEPT. TO DETERMINE IF METER CONDUIT MUST BE INSTALLED. IF REQUIRED THE CONTRACTOR SHALL SUPPLY THE WIRE AND INSTALL AS SPECIFIED.
AutoCAD SHX Text
FLOW
AutoCAD SHX Text
FLOW
AutoCAD SHX Text
FLOW
AutoCAD SHX Text
FLOW
AutoCAD SHX Text
2" METER TEST BALL VALVE
AutoCAD SHX Text
ALL METERS MUST BE EQUIPPED WITH STRAINERS OF THE SAME MANUFACTURER AS THE METER
Page 4: Meter Pits and Appurtenances - Home | Boston Water and ... · meter pit details general notes. sept. 30, 2012. 1. details shown to accommodate two different size details shown to

ELEVATION

PLAN

INSTALLATION OF REMOTE READINGDEVICES BY COMMISSION

NOTES:

Scale: Not To Scale

Boston Water andSewer Commission

DETAIL NO.DATE:

Loca

tion\F

ilena

me: V

:\eng

\ACA

D_ST

D\Te

chnic

al De

tails\

M -

Meter

Deta

ils\M

-02 -

Mete

r Pit D

etails

.dwg

Plott

ed on

: Tue

sday

, Aug

ust 1

1, 20

15 -

12:41

PM

by D

onoh

oe, W

illiam

M-02d980 HARRISON AVE., BOSTON, MA 02119(617) 989-7000 www.bwsc.org

METER PIT FOR 4, 6, 8 AND 10-INCH

FIRE FLOW METERS July 15, 2015

AutoCAD SHX Text
OF PIPE AND WALL OPENING
AutoCAD SHX Text
C
AutoCAD SHX Text
L
AutoCAD SHX Text
FINISHED GRADE
AutoCAD SHX Text
INSTALL GRADE RINGS AS NECESSARY
AutoCAD SHX Text
G FRAME AND COVER
AutoCAD SHX Text
2" METER TEST BALL VALVE
AutoCAD SHX Text
6" x 18" MECH. JT. TOMECH. JT. WALL PIPE THROUGH 12" OPENING
AutoCAD SHX Text
OF METER PIT
AutoCAD SHX Text
OF METER PIT
AutoCAD SHX Text
FLANGED TO PLAIN END ADAPTER (LENGTH TO FIT CONDITION)
AutoCAD SHX Text
BOSTON WATER AND SEWER COMMISSION STANDARD TYPE A-2 METER PIT
AutoCAD SHX Text
FLOW
AutoCAD SHX Text
FLOW
AutoCAD SHX Text
FLOW
AutoCAD SHX Text
FLOW
AutoCAD SHX Text
1.BY-PASS METER CAN BE 1 SIZE SMALLER THAN BY-PASS METER CAN BE 1 SIZE SMALLER THAN MAIN METER. 2.ALL GATES TO BE TEFLON COATED. ALL GATES TO BE TEFLON COATED. 3.CONTRACTOR SHALL NOTIFY BWSC METER DEPT. CONTRACTOR SHALL NOTIFY BWSC METER DEPT. TO DETERMINE IF METER CONDUIT MUST BE INSTALLED. IF REQUIRED THE CONTRACTOR SHALL SUPPLY THE WIRE AND INSTALL AS SPECIFIED.
AutoCAD SHX Text
4 PIPE DIAMETERS BEFORE METER MIN.
AutoCAD SHX Text
2 PIPE DIAMETERS AFTER METER MIN.
AutoCAD SHX Text
LIFTING HOLE (TYP. OF 4)
AutoCAD SHX Text
2" METER TEST BALL VALVE
AutoCAD SHX Text
2
AutoCAD SHX Text
4
Page 5: Meter Pits and Appurtenances - Home | Boston Water and ... · meter pit details general notes. sept. 30, 2012. 1. details shown to accommodate two different size details shown to

A

A

B

B PLAN

SECTION A-A

SECTION B-B

PLAN

NOTE:

Scale: Not To Scale

Boston Water andSewer Commission

DETAIL NO.DATE:

Loca

tion\F

ilena

me: V

:\eng

\ACA

D_ST

D\Te

chnic

al De

tails\

M -

Meter

Deta

ils\M

-02 -

Mete

r Pit D

etails

.dwg

Plott

ed on

: Tue

sday

, Aug

ust 1

1, 20

15 -

12:41

PM

by D

onoh

oe, W

illiam

M-02e980 HARRISON AVE., BOSTON, MA 02119(617) 989-7000 www.bwsc.org

REINFORCING DETAILS FOR METER PITS

(1 of 2) Sept. 30, 2012

AutoCAD SHX Text
2-#5 EACH SIDE (TOTAL 8) 1 TOP LAYER,1 BOTT.,EACH SIDE
AutoCAD SHX Text
#5 @7" O.C.
AutoCAD SHX Text
10#4 AS SHOWN
AutoCAD SHX Text
9#4(3'-9"WIDE PANEL) 8#4(3'-6"WIDE PANEL) 7#4(3'-0"WIDE PANEL) 6#4(2'-6"WIDE PANEL)
AutoCAD SHX Text
#5 @7"O.C.
AutoCAD SHX Text
#3 @14"(TYP.)
AutoCAD SHX Text
PROVIDE LIFTING HOOKS 1 EACH END IF REQUIRED (MIN.1/2"DIA.BAR)PANELS MUST ONLY BE LIFTED FROM ENDS
Page 6: Meter Pits and Appurtenances - Home | Boston Water and ... · meter pit details general notes. sept. 30, 2012. 1. details shown to accommodate two different size details shown to

PLAN OF WALL REINFORCING

CC

NOTE:

SECTION C-C

PLAN OF FOOTING REINFORCING

DD

SECTION D-D

Scale: Not To Scale

Boston Water andSewer Commission

DETAIL NO.DATE:

Loca

tion\F

ilena

me: V

:\eng

\ACA

D_ST

D\Te

chnic

al De

tails\

M -

Meter

Deta

ils\M

-02 -

Mete

r Pit D

etails

.dwg

Plott

ed on

: Tue

sday

, Aug

ust 1

1, 20

15 -

12:41

PM

by D

onoh

oe, W

illiam

M-02f980 HARRISON AVE., BOSTON, MA 02119(617) 989-7000 www.bwsc.org

REINFORCING DETAILS FOR METER PITS

(2 of 2) Sept. 30, 2012

AutoCAD SHX Text
WELDED WIRE FABRIC
AutoCAD SHX Text
WELDED WIRE FABRIC
AutoCAD SHX Text
WELDED WIRE FABRIC
AutoCAD SHX Text
WELDED WIRE FABRIC
AutoCAD SHX Text
RELOCATE THESE BARS AS REQUIRED TO AVOID OPENING
AutoCAD SHX Text
4x4xW2.9xW2.9 WELDED WIRE FABRIC EACH FACE
AutoCAD SHX Text
2-#5 (EACH SIDE)
AutoCAD SHX Text
2-#5 OUTER FACE
AutoCAD SHX Text
2-#5 INNER FACE
AutoCAD SHX Text
#3 TIES@18" (TYP. 4 SIDES)
AutoCAD SHX Text
#3 TIES@18"
AutoCAD SHX Text
1 #5 (EACH CORNER)
Page 7: Meter Pits and Appurtenances - Home | Boston Water and ... · meter pit details general notes. sept. 30, 2012. 1. details shown to accommodate two different size details shown to

GENERAL NOTES:

Scale: Not To Scale

Boston Water andSewer Commission

DETAIL NO.DATE:

Loca

tion\F

ilena

me: V

:\eng

\ACA

D_ST

D\Te

chnic

al De

tails\

M -

Meter

Deta

ils\M

-02 -

Mete

r Pit D

etails

.dwg

Plott

ed on

: Tue

sday

, Aug

ust 1

1, 20

15 -

12:41

PM

by D

onoh

oe, W

illiam

M-02g980 HARRISON AVE., BOSTON, MA 02119(617) 989-7000 www.bwsc.org

METER PIT DETAILS GENERAL NOTES

Sept. 30, 2012

AutoCAD SHX Text
1.DETAILS SHOWN TO ACCOMMODATE TWO DIFFERENT SIZE DETAILS SHOWN TO ACCOMMODATE TWO DIFFERENT SIZE METERS ARE DRAWN FOR THE LARGER SIZE. IF USED FOR SMALLER SIZE METER, THE PROPER SIZE SLEEVES AND OTHER NECESSARY ADAPTATION WILL HAVE TO BE MADE TO SUIT THE METER PIT DIMENSIONS. 2.MAKE FLANGE TO PLAIN END ADAPTER PIECES SLIGHTLY MAKE FLANGE TO PLAIN END ADAPTER PIECES SLIGHTLY SHORTER THAN REQUIRED TO ALLOW FOR SOME SLIDING OF ADAPTER PIECES INTO MECHANICAL JOINT WALL PIPE WHEN FLANGES AT METER ARE DISCONNECTED FOR REMOVAL OR INSTALLATION OF METER. 3.AFTER INSTALLING MECHANICAL JOINT WALL PIPES WITH AFTER INSTALLING MECHANICAL JOINT WALL PIPES WITH CENTER RING FLANGE IN THE MIDDLE OF MASONRY OPENING, AND AFTER ALL PIPING HAS BEEN ALIGNED AND CONNECTED, CAULK THE SPACE BETWEEN WALL PIPE AND MASONRY WITH OAKUM AND A CEMENT MORTAR GROUT. 4.ALL CONCRETE USED IN CONSTRUCTION OF THESE METER ALL CONCRETE USED IN CONSTRUCTION OF THESE METER PITS TO BE OF 3000 P.S.I. WITH A MAXIMUM AGGREGATE SIZE OF " 34" 5.REINFORCING STEEL BARS ARE TO BE DEFORMED BARS OF REINFORCING STEEL BARS ARE TO BE DEFORMED BARS OF NEW BILLET STEEL-GRADE 6 6.METER PIT COVERS SHALL BE A2424 HALLIDAY PRODUCT METER PIT COVERS SHALL BE A2424 HALLIDAY PRODUCT OR EQUAL. PEDESTRIAN TRAFFIC COVERS SHALL BE SD300 RATED WITH LIFTING SPRINGS. VEHICULAR TRAFFIC COVERS SHALL BE H20 RATED WITH LIFTING SPRINGS.