mercmaster led generation 3 series luminaires with ......• led l70 reported at 60,000 hours. •...

20
Applications Enclosed and gasketed fixtures suitable for use in: — A wide range of industrial, chemical processing and other areas where flammable gases and vapors or combustible dusts are present — Marine and wet locations — Suitability includes use where there may be simultaneous exposure to flammable gases and vapors or combustible dusts Typical applications include: — Power plants — Processing plants — Chemical plants — Oil refineries — Waste and sewage treatment — Other areas where dust, water, dirt and rough usage are a problem Features Provides up to 1400 lumens illumination for 90 minutes of emergency lighting with clear lens or 800 lumens illumination for 180 minutes of emergency lighting. Functional diagnostic test self-initiates every 14 days after initial start up. Duration test is automatically performed once per year. Green and Red LED lights indicate charging status and provide fault warning. Simple quick disconnect connector disconnects power between LEDs and battery management module to allow maintenance in hazardous locations. Suitable for mounting heights up to 14 feet. Choice of optics for optimal light distribution in a variety of applications: Type I, Type III, Type V or Type V Wide. Choice of color temperature (CCT): 5000K cool white, 4000K neutral white or 3000K warm white. Customize to the application requirements with three different globe options: clear polycarbonate, diffused polycarbonate, and clear glass. Seven standard mounting hood designs allow for mounting in any location. Uses same mounting hoods as Mercmaster III. Retrofit adapters for Crouse-Hinds™, Killark and Mercmaster II hoods available. See Mercmaster™ CH Adapters. Hinge has high lip for added safety during installation and servicing. Hinge and bolt construction assures 360° compression at all points on fixture housing gasket for positive sealing. Swing away design of captive bolt and nut simplifies installation. Rugged housing with superior thermal design translates to long luminaire life. Mercmaster LED Generation 3 Series Luminaires with Emergency Battery Backup Enclosed and Gasketed Fixtures Luminaire housing has wiring compartment with terminal block separate for easy wiring access. Standard screw-type terminal block can accept UL/CSA 26-10 AWG wire. Standard 6 kV surge protection. Heavy duty, high temperature silicone gaskets. Photometric data and electronic drawings available upon request. Ambient Temperature: -20 ˚C to +55 ˚C (-4 ˚F to +131 ˚F) LED L70 reported at 60,000 hours. Field replaceable globes, battery management module (BMM), battery pack and LED driver. Options Globe and refractor guards available, purchase separately Safety cable available, purchase separately Drain is available to divert water existing in the conduit system, purchase separately. Standard Materials Mounting hoods and bodies: cast copperfree (4/10 of 1% max.) aluminum Gaskets: silicone All hardware and catch assemblies: stainless steel Globe: polycarbonate or glass Glass refractor guard: die cast aluminum Standard Finishes Mounting hoods, bodies and glass refractor guard: gray epoxy powder coat finish, electrostatically applied for complete uniform protection Related Products Mercmaster™ LED Generation 3 Luminaries Mercmaster™ LED Low Profile Luminaires Mercmaster™ LED Mounting Adapters MLGL NEC/CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Group E, F, G Class III Class I, Zone 2 IIC Zone 20 IIIC NEC/CEC: Type 3R, 4, 4X IP66/IP67 Simultaneous Exposure Suitable for Use in Wet Locations Standard Mode Nominal Lumens HID Equivalent Emergency Mode Nominal Lumens Model Number 3500 70-100W 1450 MLGL3H 800 MLGL3E 5500 100-150W 1450 MLGL5H 800 MLGL5E Nominal lumen value for 5000K, clear glass globe Type V. Detailed lumen information is provided in tables. Killark is a registered trademark of Hubbell Incorporated Crouse-Hinds is a registered trademarks of Cooper Crouse-Hinds. NEC/CEC ENCLOSED AND GASKETED CLASS/ZONE AND ATEX/IEC/NBR IEC ZONE 2 RATED — AREA Visit our website at www.emerson.com or contact us at (800) 621-1506. © December 2018 1

Upload: others

Post on 24-Sep-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Mercmaster LED Generation 3 Series Luminaires with ......• LED L70 reported at 60,000 hours. • Field replaceable globes, battery management module (BMM), battery pack and LED driver

Applications• Enclosedandgasketedfixturessuitableforusein:

—Awiderangeofindustrial,chemicalprocessingandotherareaswhereflammablegasesandvaporsorcombustibledustsarepresent

—Marineandwetlocations—Suitabilityincludesusewheretheremaybesimultaneous

exposuretoflammablegasesandvaporsorcombustibledusts

• Typicalapplicationsinclude:—Powerplants—Processingplants—Chemicalplants—Oilrefineries—Wasteandsewagetreatment—Otherareaswheredust,water,dirtandroughusagearea

problem

Features• Providesupto1400lumensilluminationfor90minutesof

emergencylightingwithclearlensor800lumensilluminationfor180minutesofemergencylighting.

• Functionaldiagnostictestself-initiatesevery14daysafterinitialstartup.

• Durationtestisautomaticallyperformedonceperyear.• GreenandRedLEDlightsindicatechargingstatusandprovide

faultwarning.• Simplequickdisconnectconnectordisconnectspowerbetween

LEDsandbatterymanagementmoduletoallowmaintenanceinhazardouslocations.

• Suitableformountingheightsupto14feet.• Choiceofopticsforoptimallightdistributioninavarietyof

applications:TypeI,TypeIII,TypeVorTypeVWide.• Choiceofcolortemperature(CCT):5000Kcoolwhite,4000K

neutralwhiteor3000Kwarmwhite.• Customizetotheapplicationrequirementswiththreedifferent

globeoptions:clearpolycarbonate,diffusedpolycarbonate,andclearglass.

• Sevenstandardmountinghooddesignsallowformountinginanylocation.UsessamemountinghoodsasMercmasterIII.

• RetrofitadaptersforCrouse-Hinds™,KillarkandMercmasterIIhoodsavailable.SeeMercmaster™CHAdapters.

• Hingehashighlipforaddedsafetyduringinstallationandservicing.Hingeandboltconstructionassures360°compressionatallpointsonfixturehousinggasketforpositivesealing.Swingawaydesignofcaptiveboltandnutsimplifiesinstallation.

• Ruggedhousingwithsuperiorthermaldesigntranslatestolongluminairelife.

Mercmaster™ LED Generation 3 Series Luminaires with Emergency Battery BackupEnclosed and Gasketed Fixtures

• Luminairehousinghaswiringcompartmentwithterminalblockseparateforeasywiringaccess.

• Standardscrew-typeterminalblockcanacceptUL/CSA26-10AWGwire.

• Standard6kVsurgeprotection.• Heavyduty,hightemperaturesiliconegaskets.• Photometricdataandelectronicdrawingsavailable

uponrequest.• AmbientTemperature:-20˚Cto+55˚C(-4˚Fto+131˚F)• LEDL70reportedat60,000hours.• Fieldreplaceableglobes,batterymanagementmodule(BMM),

batterypackandLEDdriver.Options• Globeandrefractorguardsavailable,purchaseseparately• Safetycableavailable,purchaseseparately• Drainisavailabletodivertwaterexistinginthe

conduitsystem,purchaseseparately.Standard Materials• Mountinghoodsandbodies:castcopperfree

(4/10of1%max.)aluminum• Gaskets:silicone• Allhardwareandcatchassemblies:stainlesssteel• Globe:polycarbonateorglass• Glassrefractorguard:diecastaluminum

Standard Finishes• Mountinghoods,bodiesandglassrefractorguard:grayepoxy

powdercoatfinish,electrostaticallyappliedforcompleteuniformprotection

Related Products• Mercmaster™LEDGeneration3Luminaries• Mercmaster™LEDLowProfileLuminaires• Mercmaster™LEDMountingAdapters

MLGL

NEC/CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Group E, F, G Class III Class I, Zone 2 IIC Zone 20 IIIC

NEC/CEC: Type 3R, 4, 4X IP66/IP67 Simultaneous Exposure Suitable for Use in Wet Locations

Standard ModeNominal Lumens HID Equivalent

Emergency ModeNominal Lumens Model Number

3500 70-100W1450 MLGL3H800 MLGL3E

5500 100-150W1450 MLGL5H800 MLGL5E

Nominal lumen value for 5000K, clear glass globe Type V. Detailed lumen information is provided in tables.

Killark is a registered trademark of Hubbell Incorporated Crouse-Hinds is a registered trademarks of Cooper Crouse-Hinds.

NEC/CEC ENClosEd aNd GaskEtEd Class/ZoNE aNd atEX/IEC/NBR IEC ZoNE 2 RatEd — aREa

Visit our website at www.emerson.com or contact us at (800) 621-1506. © December 2018

1

Page 2: Mercmaster LED Generation 3 Series Luminaires with ......• LED L70 reported at 60,000 hours. • Field replaceable globes, battery management module (BMM), battery pack and LED driver

NEC/CEC Certifications and Compliances• ULStandard:UL844;UL1598;UL50E;UL8750;UL60079-0;

UL924• CSAStandard:C22.2No.0-10;C22.2No.94.2-15;

C22.2No.137-18;C22.2No.250.0-08;C22.2No.250.13-14;CSAE60598-1:16

• NEMAANSI/IECStandards:60529• cCSAus:164460,CertificateNumber:70182640

Design Lights™ Consortium• CheckDLCQPLforcurrentlistofproducts.

Mercmaster™ LED Generation 3 Series Luminaires with Emergency Battery BackupEnclosed and Gasketed Fixtures

NEC/CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Group E, F, G Class III Class I, Zone 2 IIC Zone 20 IIIC

NEC/CEC: Type 3R, 4, 4X IP66/IP67 Simultaneous Exposure Suitable for Use in Wet Locations

NEC/

CEC

ENCl

osEd

aNd

Gas

kEtE

d Cl

ass/

ZoNE

aNd

atE

X/IEC

/NBR

IEC

ZoNE

2 R

atEd

— a

REa

Visit our website at www.emerson.com or contact us at (800) 621-1506. © December 2018

2

Page 3: Mercmaster LED Generation 3 Series Luminaires with ......• LED L70 reported at 60,000 hours. • Field replaceable globes, battery management module (BMM), battery pack and LED driver

LED Flexibility and Modular Design

Type I-Longandnarrowdistributionpatterndesignedwithwalkwaysinmind.

Type III-Wallmounteddistributionpatterndesignedwhereyouneedgoodforwardlightprojection.

Type V-Symmetricalcircledistributionpatternidealwhenyouneedevencoverageinalldirections.

Type V Wide-LiketheTypeVdistributionpatternwithmoreverticallumensdesignedtohelpspreadthelightquickerandmoreoutwards.

Choosefromthree color temperatures(CCT):3000K,4000K,and5000KFour light distribution patterns:TypeI,TypeIII,TypeVandTypeVwideforapplicationflexibility.Six mounting hoodsallowonefixturetobeconfiguredforceiling,pendant,stanchion,orwallapplications.Four globes;clearanddiffusedpolycarbonate,clearglassglobe,andprismaticrefractorprovidejusttherightlevelofdiffusion.

Safety Features Type I & Type III Hinge System

12

3

Latch Assembly and Hinge:Captive,stainlesssteellatchassembly(boltandnut)closessecurelywhileprovidingresistancetocorrosiveatmospheres.Swing-awaydesignsimplifieswiringandinstallation.Extrahighhingeprovidesadditionalprotectionagainstaccidentaldriverhousingdisengagementduringinstallationormaintenance.

TypeI&TypeIIIlightdistributionpatternsuseamultiplehingedhousingdesignwhichallowsyoutocorrectlylineupthebeampatterninyourdesireddirection.Byusingoneofthethreeavailablehingesyoucanpositionthefixtureforoptimallightoutput.

Mercmaster™ LED Generation 3 Series Luminaires with Emergency Battery BackupEnclosed and Gasketed Fixtures

NEC/CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Group E, F, G Class III Class I, Zone 2 IIC Zone 20 IIIC

NEC/CEC: Type 3R, 4, 4X IP66/IP67 Simultaneous Exposure Suitable for Use in Wet Locations

Designed for the Environment Quick Disconnect

Watertight Pendant Hood Safety Cable

Field Changeable Duration Setting

Driverhousingdesignincorporatesseparatesectionsfortheterminalblockanddriver.TheefficientthermaldesignensuresreliableheattransferfromtheLEDassemblyoutviatheheatsinkandthecast,epoxypowdercoat,aluminumbody.

SimplequickdisconnectconnectordisconnectspowerbetweenLEDsandbatterymanagementmoduletoallowmaintenanceinhazardouslocations.

NewwatertightpendanthoodprovidesprotectionagainstwateringressintheconduitutilizinganIP68cordgripwith3wireholes4mmindiameter.

Safetycableisslippedaroundthehousingthroughretentionpointsthatarecastedin.Safetycablehasbuiltinloopscombinedwithalockingcarabinertoallowforaquickandsecureinstallation.

Easyfieldchangeabledurationsettingbetween90and180minutes.

NEC/CEC ENClosEd aNd GaskEtEd Class/ZoNE aNd atEX/IEC/NBR IEC ZoNE 2 RatEd — aREa

Visit our website at www.emerson.com or contact us at (800) 621-1506. © December 2018

3

Page 4: Mercmaster LED Generation 3 Series Luminaires with ......• LED L70 reported at 60,000 hours. • Field replaceable globes, battery management module (BMM), battery pack and LED driver

Mercmaster™ LED Family Tree

NEC/CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Group E, F, G Class III Class I, Zone 2 IIC Zone 20 IIIC

NEC/CEC: Type 3R, 4, 4X IP66/IP67 Simultaneous Exposure Suitable for Use in Wet Locations

Glass Globes

VPGL-LED (Clear)

VPGL-GLASS (Clear)

Polycarbonate Globes

VPGL-DIFF (Diffused)

MLGL

See mounting hood section for part numbers.

Mercmaster™ LED Generation 3 Series Luminaires with Emergency Battery BackupEnclosed and Gasketed Fixtures

AdaptersWateright Pendant Hood

Trunnion Mount

Pendant Mount

Pendant Cone

Mount

Ceiling Mount Wall Mount

25° Stanchion Mount

90° Stanchion Mount

Wall and Stanchion

Mount Adapters

Pendant and Ceiling Mount Adapters

KPA-WT KPCT KPA KPCH KPC KPWB KPS KPST

Globe Guards (Optional Accessory)

Emergency Exit Sign (Optional Accessory)

MGU1 EXR400

NEC/

CEC

ENCl

osEd

aNd

Gas

kEtE

d Cl

ass/

ZoNE

aNd

atE

X/IEC

/NBR

IEC

ZoNE

2 R

atEd

— a

REa

Visit our website at www.emerson.com or contact us at (800) 621-1506. © December 2018

4

Page 5: Mercmaster LED Generation 3 Series Luminaires with ......• LED L70 reported at 60,000 hours. • Field replaceable globes, battery management module (BMM), battery pack and LED driver

NEC/CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Group E, F, G Class III Class I, Zone 2 IIC Zone 20 IIIC

NEC/CEC: Type 3R, 4, 4X IP66/IP67 Simultaneous Exposure Suitable for Use in Wet Locations

Orderusingcatalognumberingguidesbeloworselectcatalognumberfromtablesonfollowingpages.

3/4” NPT, 1” NPT and Metric M20 hub entries are not offered in this mounting option For lumen output information, see Lumen Values Table. Guards for the globes are ordered separately. See the Accessories for more information. Only allowed for Type V and Type V wide light distribution. Type I and Type III use a multiple hinge housing. Hub size does not apply to luminaires ordered with adapters. Adapters only certified for cCSAus.

MLG

Series:MLG-Mercmaster™

LEDGeneration3Series

Lumen(nominal):L3-3500L5-5500

HubSize:2-3/4"NPT3-1"NPT4-1-1/4"NPTstanchion5-1-1/2"NPTstanchion6-MetricM20Blank-Ifusingadapteror

nohood

ColorTemperature:C-Cool,5000KN-Neutral,4000KW-Warm,3000K

GlobeMaterial:P-ClearPolycarbonateGlobeD-DiffusedPolycarbonateGlobeG-ClearGlassGlobe

LightDistributionPattern:1-TypeI3-TypeIII5-TypeVW-TypeVWide

Voltage:BU-120-277Vac,50/60Hz;

Mounting:A-PendantB-WatertightPendantC-CeilingD-PendantConeR-90ºStanchionS-25ºStanchionT-TrunnionK-Killark™Adapter

UniversalU-Mercmaster™IIAdapter,

CeilingorPendant

V-Mercmaster™IIAdapter,StanchionorWall

W-WallX-CrouseHinds™Adapter,

CeilingorPendantY-CrouseHinds™Adapter,

StanchionorWallBlank-Nomountinghood

A L3 2 C P 5 BU H

Mercmaster™ LED Generation 3 Series Luminaires with Emergency Battery BackupEnclosed and Gasketed Fixtures

Emergency:H-90MinutesE-180Minutes

NEC/CEC ENClosEd aNd GaskEtEd Class/ZoNE aNd atEX/IEC/NBR IEC ZoNE 2 RatEd — aREa

Visit our website at www.emerson.com or contact us at (800) 621-1506. © December 2018

5

Page 6: Mercmaster LED Generation 3 Series Luminaires with ......• LED L70 reported at 60,000 hours. • Field replaceable globes, battery management module (BMM), battery pack and LED driver

Lumen Values Table

Lumen Output (Efficacy) for Clear Polycarbonate Globe

MLGL3H MLGL5H

TypeI 5000KCCT,70CRI 3200(107) 4800(104)

TypeIII 5000KCCT,70CRI 3500(117) 5200(113)

TypeV 5000KCCT,70CRI 3800(127) 5700(124)

TypeVWide 5000KCCT,70CRI 3600(119) 6000(129)

TypeI 4000KCCT,80CRI 3000(100) 4200(91)

TypeIII 4000KCCT,80CRI 3000(100) 4600(100)

TypeV 4000KCCT,80CRI 3300(110) 5000(109)

TypeVWide 4000KCCT,80CRI 2900(97) 4800(105)

TypeI 3000KCCT,80CRI 2600(87) 3800(83)

TypeIII 3000KCCT,80CRI 2800(93) 4100(89)

TypeV 3000KCCT,80CRI 3000(100) 4500(98)

TypeVWide 3000KCCT,80CRI 2900(96) 4400(94)

Lumen Output (Efficacy) for Clear Glass Globe

MLGL3H MLGL5H

TypeI 5000KCCT,70CRI 3500(117) 5300(115)

TypeIII 5000KCCT,70CRI 3700(123) 5400(117)

TypeV 5000KCCT,70CRI 4000(133) 6000(130)

TypeVWide 5000KCCT,70CRI 3600(120) 5400(117)

TypeI 4000KCCT,80CRI 3100(103) 4600(100)

TypeIII 4000KCCT,80CRI 3200(107) 4800(104)

TypeV 4000KCCT,80CRI 3600(120) 5300(115)

TypeVWide 4000KCCT,80CRI 3200(107) 4800(104)

TypeI 3000KCCT,80CRI 2800(93) 4200(91)

TypeIII 3000KCCT,80CRI 3100(102) 4400(96)

TypeV 3000KCCT,80CRI 3100(102) 4800(104)

TypeVWide 3000KCCT,80CRI 3100(101) 4600(99)

Mercmaster™ LED Generation 3 Series Luminaires with Emergency Battery BackupEnclosed and Gasketed Fixtures

NEC/CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Group E, F, G Class III Class I, Zone 2 IIC Zone 20 IIIC

NEC/CEC: Type 3R, 4, 4X IP66/IP67 Simultaneous Exposure Suitable for Use in Wet Locations

NEC/

CEC

ENCl

osEd

aNd

Gas

kEtE

d Cl

ass/

ZoNE

aNd

atE

X/IEC

/NBR

IEC

ZoNE

2 R

atEd

— a

REa

Visit our website at www.emerson.com or contact us at (800) 621-1506. © December 2018

6

Page 7: Mercmaster LED Generation 3 Series Luminaires with ......• LED L70 reported at 60,000 hours. • Field replaceable globes, battery management module (BMM), battery pack and LED driver

Mercmaster™ LED Generation 3 Series Luminaires with Emergency Battery BackupEnclosed and Gasketed Fixtures

NEC/CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Group E, F, G Class III Class I, Zone 2 IIC Zone 20 IIIC

NEC/CEC: Type 3R, 4, 4X IP66/IP67 Simultaneous Exposure Suitable for Use in Wet Locations

90 Minute Emergency Mode

ModelLumens

Polycarbonate Clear Globe Polycarbonate Diffused Globe Glass Clear Globe

MLGL3H5000KCCT,70CRI 1400 1350 1450

MLGL5H

MLGL3H4000KCCT,80CRI 1280 1230 1330

MLGL5H

MLGL3H3000KCCT,80CRI 1100 1150 1200

MLGL5H

All lumen values are typical (tolerance +/-10%). Diffused polycarbonate globe can be used with Type I, III and V wide. Refer to photometric files for lumen output information.

Lumen Output (Efficacy) for Diffused Polycarbonate Globe

MLGL3 MLGL5

TypeI 5000KCCT,70CRI 3200(108) 4900(107)

TypeIII 5000KCCT,70CRI 3300(112) 5100(110)

TypeV 5000KCCT,70CRI 3700(123) 5500(120)

TypeVWide 5000KCCT,70CRI 3400(113) 5100(110)

TypeI 4000KCCT,80CRI 2900(95) 4400(94)

TypeIII 4000KCCT,80CRI 3000(101) 4600(100)

TypeV 4000KCCT,80CRI 3200(107) 4800(104)

TypeVWide 4000KCCT,80CRI 3000(101) 4600(100)

TypeI 3000KCCT,80CRI 2700(87) 4000(85)

TypeIII 3000KCCT,80CRI 2800(92) 4200(91)

TypeV 3000KCCT,80CRI 2900(97) 4400(96)

TypeVWide 3000KCCT,80CRI 2800(91) 4200(90)

NEC/CEC ENClosEd aNd GaskEtEd Class/ZoNE aNd atEX/IEC/NBR IEC ZoNE 2 RatEd — aREa

Visit our website at www.emerson.com or contact us at (800) 621-1506. © December 2018

7

Page 8: Mercmaster LED Generation 3 Series Luminaires with ......• LED L70 reported at 60,000 hours. • Field replaceable globes, battery management module (BMM), battery pack and LED driver

Mercmaster™ LED Generation 3 Series Luminaires with Emergency Battery BackupEnclosed and Gasketed Fixtures

LED Signals

Color Timing Description

Green 1secON:1secOFF Normalchargingok,Batterynotyetfullycharged,Nofaultdetected,Testingok

Green 0.25secON:0.25secOFF Functional/DurationSelf-Teston-going

Green SteadyON Chargingok,Batteryfullycharged,Nofaultdetected,Testingok

Red 1secON:1secOFF

Faultcondition.Installationissue.Batteryisreverse,notconnectedorshorted.Functionaltestfailure,fullduration

testfailure

LEDIndicatorsOFF,LEDArrayON LEDIndicatorLights(RedandGreen)OFF NoAC,EmergencymodeON

Automatic Testing System (ATS)

Functional Full Duration

Startswithin24to45hoursaftertheinitialpowerupofthemodule Startswithin5to26daysaftertheinitialpowerofthemodule

Occursevery14daysaftertheinitialaforementionedfunctionaltest Occursevery364daysaftertheinitialaforementionedfunctionaltest

Lastsfor5minutes Lastsforthefulldurationoftheratedemergencyperiod

Atthecompletionoffunctionalandfulldurationtests,LEDindicatorwilldisplaythestatusoftheemergencyluminairewhenACispresent

LEDIndicator LEDArray

NEC/CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Group E, F, G Class III Class I, Zone 2 IIC Zone 20 IIIC

NEC/CEC: Type 3R, 4, 4X IP66/IP67 Simultaneous Exposure Suitable for Use in Wet Locations

NEC/

CEC

ENCl

osEd

aNd

Gas

kEtE

d Cl

ass/

ZoNE

aNd

atE

X/IEC

/NBR

IEC

ZoNE

2 R

atEd

— a

REa

Visit our website at www.emerson.com or contact us at (800) 621-1506. © December 2018

8

Page 9: Mercmaster LED Generation 3 Series Luminaires with ......• LED L70 reported at 60,000 hours. • Field replaceable globes, battery management module (BMM), battery pack and LED driver

Mercmaster™ LED Generation 3 Series Luminaires with Emergency Battery BackupEnclosed and Gasketed Fixtures

Electrical Ratings

Model Number Voltage Input Power Input Current (amp) Power Factor THD

MLGL3H BU

120Vac 30 0.26

>0.9 <20%

277Vac 30 0.12

MLGL5H BU

120Vac 46 0.39

>0.9 <20%

277Vac 46 0.17

NEC/CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Group E, F, G Class III Class I, Zone 2 IIC Zone 20 IIIC

NEC/CEC: Type 3R, 4, 4X IP66/IP67 Simultaneous Exposure Suitable for Use in Wet Locations

All values are typical (tolerance +/-10%).

NEC/CEC ENClosEd aNd GaskEtEd Class/ZoNE aNd atEX/IEC/NBR IEC ZoNE 2 RatEd — aREa

Visit our website at www.emerson.com or contact us at (800) 621-1506. © December 2018

9

Page 10: Mercmaster LED Generation 3 Series Luminaires with ......• LED L70 reported at 60,000 hours. • Field replaceable globes, battery management module (BMM), battery pack and LED driver

Mercmaster™ LED Generation 3 Series Luminaires with Emergency Battery BackupEnclosed and Gasketed Fixtures

Technical Data

Model Number

Max. Ambient Temperature

°C (°F)Min. Supply Wire

°C (°F)

Class I Division 2 Groups A, B, C

and DClass I, Zone 2,

Group IIC

Class II, Division 1, Groups E, F

and GZone 21,

Group IIIC

Class I, Division 2 & Class II, Division 1

MLGL340(104)

90(194)T5 T5 T6 T6 T5

55(131) T5 T5 T6 T6 T5

MLGL540(104)

90(194)T5 T5 T6 T6 T4A

55(131) T5 T5 T6 T6 T4A

NEC/CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Group E, F, G Class III Class I, Zone 2 IIC Zone 20 IIIC

NEC/CEC: Type 3R, 4, 4X IP66/IP67 Simultaneous Exposure Suitable for Use in Wet Locations

NEC/

CEC

ENCl

osEd

aNd

Gas

kEtE

d Cl

ass/

ZoNE

aNd

atE

X/IEC

/NBR

IEC

ZoNE

2 R

atEd

— a

REa

Visit our website at www.emerson.com or contact us at (800) 621-1506. © December 2018

10

“T” Numbers Represent the Maximum Internal Temperature or Maximum Surface Temperature

NEC/CEC

“T” # T1 350 325 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6

Temp.RangeºC(ºF)

351–450(664–842)

326–350(619–662)

301–325(574–617)

281–300(538–572)

261–280(502–536)

231–260(448–500)

216–230(421–446)

201–215(394–419)

181–200(358–392)

166–180(547–842)

161–165(322–329)

136–160(277–320)

121–135(250–275)

101–120(214–248)

86–100(187–212)

85(185)

T numbers represent the maximum internal temperature for Class I, Division 2 and Class I, Zone 2 locations designated by the NEC.T numbers represent the maximum surface temperature under a dust blanket for Class II, Division 1 and Class I, Zone 2 as designated by the NEC or Zone 2

(Gas) and 22 (Dust) locations as designated by the IEC.

Page 11: Mercmaster LED Generation 3 Series Luminaires with ......• LED L70 reported at 60,000 hours. • Field replaceable globes, battery management module (BMM), battery pack and LED driver

Mercmaster™ LED Generation 3 Series Luminaires with Emergency Battery BackupEnclosed and Gasketed Fixtures

Catalog Number for Driver Housing and Globe

Lumen Level CCT Optics

Clear Polycarbonate Globe

Polycarbonate Diffused Globe

Clear Glass Globe

90 Min 180 Min 90 Min 180 Min 90 Min 180 Min

3K 5000K

TypeI MLGL3CP1BUH MLGL3CP1BUE MLGL3CP1BUH MLGL3CP1BUE MLGL3CG1BUH MLGL3CG1BUE

TypeIII MLGL3CP3BUH MLGL3CP3BUE MLGL3CP3BUH MLGL3CP3BUE MLGL3CG3BUH MLGL3CG3BUE

TypeV MLGL3CP5BUH MLGL3CP5BUE MLGL3CP5BUH MLGL3CP5BUE MLGL3CG5BUH MLGL3CG5BUE

TypeVWide

MLGL3CPWBUH MLGL3CPWBUE MLGL3CPWBUH MLGL3CPWBUE MLGL3CGWBUH MLGL3CGWBUE

5K 5000K

TypeI MLGL5CP1BUH MLGL5CP1BUE MLGL5CP1BUH MLGL5CP1BUE MLGL5CG1BUH MLGL5CG1BUE

TypeIII MLGL5CP3BUH MLGL5CP3BUE MLGL5CP3BUH MLGL5CP3BUE MLGL5CG3BUH MLGL5CG3BUE

TypeV MLGL5CP5BUH MLGL5CP5BUE MLGL5CP5BUH MLGL5CP5BUE MLGL5CG5BUH MLGL5CG5BUE

TypeVWide

MLGL5CPWBUH MLGL5CPWBUE MLGL5CPWBUH MLGL5CPWBUE MLGL5CGWBUH MLGL5CGWBUE

For other CCT options, change the 6th digit in part number from “C” to “W” for Warm 3000K CCT or “N” for Neutral 4000K CCT.Example: MLGL7CP5BUH to “W” for Warm, MLGL7WP5BUH.

Guards are available. See following pages for accessory ordering information.

NEC/CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Group E, F, G Class III Class I, Zone 2 IIC Zone 20 IIIC

NEC/CEC: Type 3R, 4, 4X IP66/IP67 Simultaneous Exposure Suitable for Use in Wet Locations

NEC/CEC ENClosEd aNd GaskEtEd Class/ZoNE aNd atEX/IEC/NBR IEC ZoNE 2 RatEd — aREa

Visit our website at www.emerson.com or contact us at (800) 621-1506. © December 2018

11

Page 12: Mercmaster LED Generation 3 Series Luminaires with ......• LED L70 reported at 60,000 hours. • Field replaceable globes, battery management module (BMM), battery pack and LED driver

Mounting Hoods

Description Weight in kg (lbs) Hub Size Catalog Number

Pendant

OneHub,RigidMounting1.0(2.3)

3/4 KPA-75

1 KPA-100

M20 KPA-M20

Watertight Pendant Hood

OneHub3/4 KPA-75-WT

1 KPA-100-WT

Pendant Cone

OneHub,RigidMounting1.1(2.5)

3/4 KPCH-75

1 KPCH-100

M20 KPCH-M20

Trunnion

FiveHubs,FourClose-UpPlugs 3/4 KPCT-75

1 KPCT-100

Ceiling

FiveHubs,FourClose-UpPlugs1.4(3.0)

3/4 KPC-75

1 KPC-100

M20 KPC-M20

Wall

FiveHubs,FourClose-UpPlugs1.8(4.0)

3/4 KPWB-75

1 KPWB-100

M20 KPWB-M20

25° Stanchion

OneHub1.5(3.3)

1-1/4 KPS-125

1-1/2 KPS-150

90° Stanchion

OneHub1.7(3.8)

1-1/4 KPST-125

1-1/2 KPST-150

Mercmaster™ LED Generation 3 Series Luminaires with Emergency Battery BackupEnclosed and Gasketed Fixtures

NEC/CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Group E, F, G Class III Class I, Zone 2 IIC Zone 20 IIIC

NEC/CEC: Type 3R, 4, 4X IP66/IP67 Simultaneous Exposure Suitable for Use in Wet Locations

NEC/

CEC

ENCl

osEd

aNd

Gas

kEtE

d Cl

ass/

ZoNE

aNd

atE

X/IEC

/NBR

IEC

ZoNE

2 R

atEd

— a

REa

Visit our website at www.emerson.com or contact us at (800) 621-1506. © December 2018

12

Page 13: Mercmaster LED Generation 3 Series Luminaires with ......• LED L70 reported at 60,000 hours. • Field replaceable globes, battery management module (BMM), battery pack and LED driver

Accessories and Replacement Parts

Description Weight in kg (lbs) Catalog Number

Globes and Gaskets

ClearGlobe(polycarbonate)0.2(0.5)

VPGL-LED

DiffusedGlobe(polycarbonate)0.2(0.5)

VPGL-DIFF

GlassGlobe—Clear0.8(1.7)

VPGL-GLASS

Mercmaster™ LED Generation 3 Series Luminaires with Emergency Battery BackupEnclosed and Gasketed Fixtures

NEC/CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Group E, F, G Class III Class I, Zone 2 IIC Zone 20 IIIC

NEC/CEC: Type 3R, 4, 4X IP66/IP67 Simultaneous Exposure Suitable for Use in Wet Locations

Mounting Hood Adapters

Manufacturer Installed Mounting Hood Appleton Adapter Catalog Number

Crouse-Hinds™

Champ

APM2/3-PendantCM2/3-Ceiling

HPM2-FlexiblePendantMMADCHVS

Appleton™Mercmaster™II

LPA75/100-PendantLPC75/100-Ceiling MMADIIS

Crouse-Hinds™

Champ

TWM2/3-WallJM5-25°AngleStanchionPM5-90°StraightStanchion

MMADCHVA

Appleton™Mercmaster™II

LPWB75,LPWB100-WallLPS125,LPS150-25°AngleStanchion MMADIIA

Killark™

VMX2B,VMX3B,VMX6B,VMX7B,VMX9B-CeilingVMA2B,VMA3B-Pendant

VMD4B,VMD5B,VMS4B,VMS5B-StanchionVMB2B,VMB3B-Wall

VMC2B,VMC3B-PendantCone

MMADKVA

NEC/CEC ENClosEd aNd GaskEtEd Class/ZoNE aNd atEX/IEC/NBR IEC ZoNE 2 RatEd — aREa

Visit our website at www.emerson.com or contact us at (800) 621-1506. © December 2018

13

Page 14: Mercmaster LED Generation 3 Series Luminaires with ......• LED L70 reported at 60,000 hours. • Field replaceable globes, battery management module (BMM), battery pack and LED driver

Replacement Drivers

Voltage Driver Wattage Luminaire ModelConstant Current

Settings Catalog Number

BU50Watt MLGL3

500mA APMS050C135UD50

BH 500mA APMS050C135HD50

BU50Watt MLGL5

780mA APMS050C135UD78

BH 780mA APMS050C135HD78

Mercmaster™ LED Generation 3 Series Luminaires with Emergency Battery BackupEnclosed and Gasketed Fixtures

Luminaire Weights

Model Number Weight in kg (lbs)

MLGL3H 12.4(15.35)

MLGL5H 12.4(15.35)

NEC/CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Group E, F, G Class III Class I, Zone 2 IIC Zone 20 IIIC

NEC/CEC: Type 3R, 4, 4X IP66/IP67 Simultaneous Exposure Suitable for Use in Wet Locations

Accessories and Replacement Parts

Description Weight in kg (lbs) Catalog Number

Globe Guards and Safety Chain

GlobeGuard0.2(0.4) MGU1

SafetyCable0.2(0.4)

LEDSC

Exit Sign

EmergencyExitsign EXR-400

Drain Plug

3”long,1/2”tradesizedrainassemblyusedtodivertwaterexistingintheconduitsystem

0.4(0.9)LEDDR3

Replacement Battery Pack BPMLLED

Replacement Battery Management Module BMMLLED

Replacement Fuse (Emergency system) MLF3

NEC/

CEC

ENCl

osEd

aNd

Gas

kEtE

d Cl

ass/

ZoNE

aNd

atE

X/IEC

/NBR

IEC

ZoNE

2 R

atEd

— a

REa

Visit our website at www.emerson.com or contact us at (800) 621-1506. © December 2018

14

Page 15: Mercmaster LED Generation 3 Series Luminaires with ......• LED L70 reported at 60,000 hours. • Field replaceable globes, battery management module (BMM), battery pack and LED driver

Dimensional Drawings

MLGL3H to MLGL5H

Driver Housing

209.6 mm [8.25 in]

224.3 mm [8.83 in]

321.9 mm [12.67 in]

Ø374.6 mm [14.75 in]

232.3 mm [9.15 in]

383.6 mm [15.10 in]

415.2 mm [16.35 in]

25° Ø374.6 mm [14.75 in]

248.6 mm [9.79 in]

434.8 mm [17.12 in]

469.0 mm [18.46 in]

Ø374.6 mm [14.75 in]

257.0 mm [10.12 in]

103.1 mm [4.06 in]

Ø374.6 mm [14.75 in]

Ø374.6 mm [14.75 in]

Ø374.6 mm [14.75 in] 236.7 mm

[9.32 in]

198.1 mm [7.80 in]

Ø375.0 mm [14.76 in]

Ø372.9 mm [14.68 in]

Ø374.7 mm [14.75 in]

257.6 mm [10.14 in]

25

Watertight Pendant

245.6 mm [9.67 in]

387.0 mm [15.23 in]

274.3 mm [10.80 in]

415.7 mm [16.36 in]

203.6 mm [8.01 in]

345.8 mm [13.61 in]

339.7 mm [13.37 in]

339.7 mm [13.37 in]

LITTLE PRIMO

BIG PRIMO

LOW PROFILE 1.5

Ø374.7 mm [14.75 in]

Ø374.7 mm [14.75 in]

Ø374.7 mm [14.75 in]

Ø374.7 mm [14.75 in]

Pendant

209.6 mm [8.25 in]

224.3 mm [8.83 in]

321.9 mm [12.67 in]

Ø374.6 mm [14.75 in]

232.3 mm [9.15 in]

383.6 mm [15.10 in]

415.2 mm [16.35 in]

25° Ø374.6 mm [14.75 in]

248.6 mm [9.79 in]

434.8 mm [17.12 in]

469.0 mm [18.46 in]

Ø374.6 mm [14.75 in]

257.0 mm [10.12 in]

103.1 mm [4.06 in]

Ø374.6 mm [14.75 in]

Ø374.6 mm [14.75 in]

Ø374.6 mm [14.75 in] 236.7 mm

[9.32 in]

198.1 mm [7.80 in]

Ø375.0 mm [14.76 in]

Ø372.9 mm [14.68 in]

Ø374.7 mm [14.75 in]

257.6 mm [10.14 in]

25

Mercmaster™ LED Generation 3 Series Luminaires with Emergency Battery BackupEnclosed and Gasketed Fixtures

NEC/CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Group E, F, G Class III Class I, Zone 2 IIC Zone 20 IIIC

NEC/CEC: Type 3R, 4, 4X IP66/IP67 Simultaneous Exposure Suitable for Use in Wet Locations

NEC/CEC ENClosEd aNd GaskEtEd Class/ZoNE aNd atEX/IEC/NBR IEC ZoNE 2 RatEd — aREa

Visit our website at www.emerson.com or contact us at (800) 621-1506. © December 2018

15

Page 16: Mercmaster LED Generation 3 Series Luminaires with ......• LED L70 reported at 60,000 hours. • Field replaceable globes, battery management module (BMM), battery pack and LED driver

Dimensional Drawings

MLGL3H to MLGL5H

Pendant Cone

209.6 mm [8.25 in]

224.3 mm [8.83 in]

321.9 mm [12.67 in]

Ø374.6 mm [14.75 in]

232.3 mm [9.15 in]

383.6 mm [15.10 in]

415.2 mm [16.35 in]

25° Ø374.6 mm [14.75 in]

248.6 mm [9.79 in]

434.8 mm [17.12 in]

469.0 mm [18.46 in]

Ø374.6 mm [14.75 in]

257.0 mm [10.12 in]

103.1 mm [4.06 in]

Ø374.6 mm [14.75 in]

Ø374.6 mm [14.75 in]

Ø374.6 mm [14.75 in] 236.7 mm

[9.32 in]

198.1 mm [7.80 in]

Ø375.0 mm [14.76 in]

Ø372.9 mm [14.68 in]

Ø374.7 mm [14.75 in]

257.6 mm [10.14 in]

25

Ceiling

209.6 mm [8.25 in]

224.3 mm [8.83 in]

321.9 mm [12.67 in]

Ø374.6 mm [14.75 in]

232.3 mm [9.15 in]

383.6 mm [15.10 in]

415.2 mm [16.35 in]

25° Ø374.6 mm [14.75 in]

248.6 mm [9.79 in]

434.8 mm [17.12 in]

469.0 mm [18.46 in]

Ø374.6 mm [14.75 in]

257.0 mm [10.12 in]

103.1 mm [4.06 in]

Ø374.6 mm [14.75 in]

Ø374.6 mm [14.75 in]

Ø374.6 mm [14.75 in] 236.7 mm

[9.32 in]

198.1 mm [7.80 in]

Ø375.0 mm [14.76 in]

Ø372.9 mm [14.68 in]

Ø374.7 mm [14.75 in]

257.6 mm [10.14 in]

25

Wall Mount

209.6 mm [8.25 in]

224.3 mm [8.83 in]

321.9 mm [12.67 in]

Ø374.6 mm [14.75 in]

232.3 mm [9.15 in]

383.6 mm [15.10 in]

415.2 mm [16.35 in]

25° Ø374.6 mm [14.75 in]

248.6 mm [9.79 in]

434.8 mm [17.12 in]

469.0 mm [18.46 in]

Ø374.6 mm [14.75 in]

257.0 mm [10.12 in]

103.1 mm [4.06 in]

Ø374.6 mm [14.75 in]

Ø374.6 mm [14.75 in]

Ø374.6 mm [14.75 in] 236.7 mm

[9.32 in]

198.1 mm [7.80 in]

Ø375.0 mm [14.76 in]

Ø372.9 mm [14.68 in]

Ø374.7 mm [14.75 in]

257.6 mm [10.14 in]

25

Mercmaster™ LED Generation 3 Series Luminaires with Emergency Battery BackupEnclosed and Gasketed Fixtures

NEC/CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Group E, F, G Class III Class I, Zone 2 IIC Zone 20 IIIC

NEC/CEC: Type 3R, 4, 4X IP66/IP67 Simultaneous Exposure Suitable for Use in Wet Locations

NEC/

CEC

ENCl

osEd

aNd

Gas

kEtE

d Cl

ass/

ZoNE

aNd

atE

X/IEC

/NBR

IEC

ZoNE

2 R

atEd

— a

REa

Visit our website at www.emerson.com or contact us at (800) 621-1506. © December 2018

16

Page 17: Mercmaster LED Generation 3 Series Luminaires with ......• LED L70 reported at 60,000 hours. • Field replaceable globes, battery management module (BMM), battery pack and LED driver

Dimensional Drawings

MLGL3H to MLGL5H

Trunnion Mount

Luminaire with Small Heat Sink

462.3 mm [18.20 in]

501.5 mm [19.74 in]

502.5 mm [19.78 in]

478.2 mm [18.83 in]

336.9 mm [13.26 in]

[14.04 in]356.5 mm

Ø374.7 mm [14.75 in]

Ø374.7 mm [14.75 in]

Ø374.7 mm [14.75 in]

Ø374.7 mm [14.75 in]

448.2 mm [17.65 in]

306.9 mm [12.08 in]

435.2 mm [17.13 in]

313.0 mm [12.32 in]

480.2 mm [18.91 in]

480.3 mm [18.91 in]

Ø374.7 mm [14.75 in]

Ø374.7 mm [14.75 in]

Ø374.7 mm [14.75 in]

Ø374.7 mm [14.75 in]

Luminaire with Large Heat Sink

25 Degree Stanchion

209.6 mm [8.25 in]

224.3 mm [8.83 in]

321.9 mm [12.67 in]

Ø374.6 mm [14.75 in]

232.3 mm [9.15 in]

383.6 mm [15.10 in]

415.2 mm [16.35 in]

25° Ø374.6 mm [14.75 in]

248.6 mm [9.79 in]

434.8 mm [17.12 in]

469.0 mm [18.46 in]

Ø374.6 mm [14.75 in]

257.0 mm [10.12 in]

103.1 mm [4.06 in]

Ø374.6 mm [14.75 in]

Ø374.6 mm [14.75 in]

Ø374.6 mm [14.75 in] 236.7 mm

[9.32 in]

198.1 mm [7.80 in]

Ø375.0 mm [14.76 in]

Ø372.9 mm [14.68 in]

Ø374.7 mm [14.75 in]

257.6 mm [10.14 in]

25

90 Degree Stanchion

209.6 mm [8.25 in]

224.3 mm [8.83 in]

321.9 mm [12.67 in]

Ø374.6 mm [14.75 in]

232.3 mm [9.15 in]

383.6 mm [15.10 in]

415.2 mm [16.35 in]

25° Ø374.6 mm [14.75 in]

248.6 mm [9.79 in]

434.8 mm [17.12 in]

469.0 mm [18.46 in]

Ø374.6 mm [14.75 in]

257.0 mm [10.12 in]

103.1 mm [4.06 in]

Ø374.6 mm [14.75 in]

Ø374.6 mm [14.75 in]

Ø374.6 mm [14.75 in] 236.7 mm

[9.32 in]

198.1 mm [7.80 in]

Ø375.0 mm [14.76 in]

Ø372.9 mm [14.68 in]

Ø374.7 mm [14.75 in]

257.6 mm [10.14 in]

25

Mercmaster™ LED Generation 3 Series Luminaires with Emergency Battery BackupEnclosed and Gasketed Fixtures

NEC/CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Group E, F, G Class III Class I, Zone 2 IIC Zone 20 IIIC

NEC/CEC: Type 3R, 4, 4X IP66/IP67 Simultaneous Exposure Suitable for Use in Wet Locations

NEC/CEC ENClosEd aNd GaskEtEd Class/ZoNE aNd atEX/IEC/NBR IEC ZoNE 2 RatEd — aREa

Visit our website at www.emerson.com or contact us at (800) 621-1506. © December 2018

17

Page 18: Mercmaster LED Generation 3 Series Luminaires with ......• LED L70 reported at 60,000 hours. • Field replaceable globes, battery management module (BMM), battery pack and LED driver

Photometric Data — DATA SHOWN IS ABSOLUTEType V, Clear Polycarbonate 5000K CCTREPORT NUMBER: MLLED2CP5BUH+EMR

Luminaire Lumens 1,404

POLAR CANDELA DISTRIBUTION ISOFOOT CANDLE PLOT ZONAL LUMEN SUMMARY

180° 170° 160° 150° 140°

130°

120°

110°

100°

90°

80°

70°

60°

525

630

420

315

105

210

315

420

525

630

105

210

0

50°

40°30°20°10°0°

- Max CD: 145°H- 45° H- 67.5° H

- 22.5° H

- 90° H- 0° H

2

2

3

1 0

1

0

1

2

3

2 fc5 fc

Point of Max FC: 3.96

1 fc

20 fc30 fc

2.5 fc0.1 fc

1 fc50% Max Cd

0.5 fc

5 fc0.2 fc

1 2 3

House Side

Street Side

Zone Lumens % Luminaire0-30 407.0 29%0-40 763.6 54.4%0-60 1,388.0 98.8%60-90 16.4 1.2%70-100 3.5 0.3%90-120 0.1 0%0-90 1,404.4 100%90-180 0.1 0%0-180 1,404.5 100%

LUMENS PER ZONEZone Lumens % Total Zone Lumens % Total0-10 44.3 3.2% 90-100 0.1 0%10-20 130.2 9.3% 100-110 0 0%20-30 232.5 16.6% 110-120 0 0%30-40 356.6 25.4% 120-130 0 0%40-50 424.6 30.2% 130-140 0 0%50-60 199.9 14.2% 140-150 0 0%60-70 12.9 0.9% 150-160 0 0%70-80 2.4 0.2% 160-170 0 0%80-90 1.1 0.1% 170-180 0 0%

Type V, Diffused Polycarbonate 5000K CCTREPORT NUMBER: MLLED2CD5BUH+EMR

Luminaire Lumens 1,369

POLAR CANDELA DISTRIBUTION ISOFOOT CANDLE PLOT ZONAL LUMEN SUMMARY

180° 170° 160° 150° 140°

130°

120°

110°

100°

90°

80°

70°

60°

433

520

347

260

87

173

260

347

433

520

87

173

0

50°

40°30°20°10°0°

- Max CD: 145°H- 45° H- 67.5° H

- 22.5° H

- 90° H- 0° H

2

2

3

1 0

1

0

1

2

3

2 fc5 fc

Point of Max FC: 4.36

1 fc

20 fc30 fc

2.5 fc0.1 fc

1 fc50% Max Cd

0.5 fc

5 fc0.2 fc

1 2 3

House Side

Street Side

Zone Lumens % Luminaire0-30 395.3 28.9%0-40 702.3 51.3%0-60 1,231.5 89.9%60-90 126.7 9.2%70-100 44.8 3.3%90-120 10.6 0.8%0-90 1,358.2 99.2%90-180 11.1 0.8%0-180 1,369.3 100%

LUMENS PER ZONEZone Lumens % Total Zone Lumens % Total0-10 43.5 3.2% 90-100 4.2 0.3%10-20 129.9 9.5% 100-110 4.7 0.3%20-30 221.9 16.2% 110-120 1.8 0.1%30-40 307.0 22.4% 120-130 0.5 0%40-50 321.3 23.5% 130-140 0 0%50-60 208.0 15.2% 140-150 0 0%60-70 86.0 6.3% 150-160 0 0%70-80 31.5 2.3% 160-170 0 0%80-90 9.1 0.7% 170-180 0 0%

Mercmaster™ LED Generation 3 Series Luminaires with Emergency Battery BackupEnclosed and Gasketed Fixtures

NEC/CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Group E, F, G Class III Class I, Zone 2 IIC Zone 20 IIIC

NEC/CEC: Type 3R, 4, 4X IP66/IP67 Simultaneous Exposure Suitable for Use in Wet Locations

LED/

ArEA

: NEC

/CEC

EmE

rgEN

Cy

Visit our website at www.emerson.com or contact us at (800) 621-1506. © September 2018

18

Page 19: Mercmaster LED Generation 3 Series Luminaires with ......• LED L70 reported at 60,000 hours. • Field replaceable globes, battery management module (BMM), battery pack and LED driver

Photometric Data — DATA SHOWN IS ABSOLUTEType V, Clear Glass 5000K CCTREPORT NUMBER: MLLED2CG5BUH+EMR

Luminaire Lumens 1,460

POLAR CANDELA DISTRIBUTION ISOFOOT CANDLE PLOT ZONAL LUMEN SUMMARY

180° 170° 160° 150° 140°

130°

120°

110°

100°

90°

80°

70°

60°

558

670

447

335

112

223

335

447

558

670

112

223

0

50°

40°30°20°10°0°

- Max CD: 145°H- 45° H- 67.5° H

- 22.5° H

- 90° H- 0° H

2

2

3

1 0

1

0

1

2

3

2 fc5 fc

Point of Max FC: 3.76

1 fc

20 fc30 fc

2.5 fc0.1 fc

1 fc50% Max Cd

0.5 fc

5 fc0.2 fc

1 2 3

House Side

Street Side

Zone Lumens % Luminaire0-30 420.1 28.8%0-40 792.8 54.3%0-60 1,443.4 98.8%60-90 16.8 1.1%70-100 3.0 0.2%90-120 0.1 0%0-90 1,460.2 100%90-180 0.1 0%0-180 1,460.2 100%

LUMENS PER ZONEZone Lumens % Total Zone Lumens % Total0-10 44.3 3.0% 90-100 0.1 0%10-20 133.9 9.2% 100-110 0 0%20-30 242.0 16.6% 110-120 0 0%30-40 372.6 25.5% 120-130 0 0%40-50 444.7 30.5% 130-140 0 0%50-60 205.9 14.1% 140-150 0 0%60-70 13.8 0.9% 150-160 0 0%70-80 2.1 0.1% 160-170 0 0%80-90 0.8 0.1% 170-180 0 0%

Type V, Clear Polycarbonate 4000K CCTREPORT NUMBER: MLLED4NG5BUH+EMR

Luminaire Lumens 1,330

POLAR CANDELA DISTRIBUTION ISOFOOT CANDLE PLOT ZONAL LUMEN SUMMARY

180° 170° 160° 150° 140°

130°

120°

110°

100°

90°

80°

70°

60°

508

610

407

305

102

203

305

407

508

610

102

203

0

50°

40°30°20°10°0°

- 45° H- 67.5° H

- 22.5° H- 90° H- 0° H

2

2

3

1 0

1

0

1

2

3

2 fc5 fc

Point of Max FC: 3.40

1 fc

20 fc30 fc

2.5 fc0.1 fc

1 fc50% Max Cd

0.5 fc

5 fc0.2 fc

1 2 3

House Side

Street Side

Zone Lumens % Luminaire0-30 392.5 29.5%0-40 733.5 55.1%0-60 1,315.4 98.9%60-90 15.0 1.1%70-100 2.6 0.2%90-120 0 0%0-90 1,330.4 100%90-180 0 0%0-180 1,330.4 100%

LUMENS PER ZONEZone Lumens % Total Zone Lumens % Total0-10 41.9 3.1% 90-100 0 0%10-20 125.8 9.5% 100-110 0 0%20-30 224.8 16.9% 110-120 0 0%30-40 341.0 25.6% 120-130 0 0%40-50 399.6 30.0% 130-140 0 0%50-60 182.3 13.7% 140-150 0 0%60-70 12.4 0.9% 150-160 0 0%70-80 1.9 0.1% 160-170 0 0%80-90 0.7 0.1% 170-180 0 0%

Mercmaster™ LED Generation 3 Series Luminaires with Emergency Battery BackupEnclosed and Gasketed Fixtures

NEC/CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Group E, F, G Class III Class I, Zone 2 IIC Zone 20 IIIC

NEC/CEC: Type 3R, 4, 4X IP66/IP67 Simultaneous Exposure Suitable for Use in Wet Locations

LED/ArEA: NEC/CEC EmErgENCy

Visit our website at www.emerson.com or contact us at (800) 621-1506. © September 2018

19

Page 20: Mercmaster LED Generation 3 Series Luminaires with ......• LED L70 reported at 60,000 hours. • Field replaceable globes, battery management module (BMM), battery pack and LED driver

Photometric Data — DATA SHOWN IS ABSOLUTEType V, Clear Glass 4000K CCTREPORT NUMBER: MLLED4WG5BUH+EMR

Luminaire Lumens 1,207

POLAR CANDELA DISTRIBUTION ISOFOOT CANDLE PLOT ZONAL LUMEN SUMMARY

180° 170° 160° 150° 140°

130°

120°

110°

100°

90°

80°

70°

60°

458

550

367

275

92

183

275

367

458

550

92

183

0

50°

40°30°20°10°0°

- 45° H- 67.5° H

- 22.5° H

- 90° H- 0° H- Max CD: 145°H

2

2

3

1 0

1

0

1

2

3

2 fc5 fc

Point of Max FC: 3.06

1 fc

20 fc30 fc

2.5 fc0.1 fc

1 fc50% Max Cd

0.5 fc

5 fc0.2 fc

1 2 3

House Side

Street Side

Zone Lumens % Luminaire0-30 355.1 29.4%0-40 659.9 54.6%0-60 1,193.4 98.8%60-90 14.4 1.2%70-100 2.4 0.2%90-120 0 0%0-90 1,207.8 100%90-180 0 0%0-180 1,207.8 100%

LUMENS PER ZONEZone Lumens % Total Zone Lumens % Total0-10 38.1 3.2% 90-100 0 0%10-20 114.1 9.4% 100-110 0 0%20-30 202.9 16.8% 110-120 0 0%30-40 304.8 25.2% 120-130 0 0%40-50 360.5 29.8% 130-140 0 0%50-60 173.0 14.3% 140-150 0 0%60-70 12.0 1.0% 150-160 0 0%70-80 1.7 0.1% 160-170 0 0%80-90 0.7 0.1% 170-180 0 0%

Mercmaster™ LED Generation 3 Series Luminaires with Emergency Battery BackupEnclosed and Gasketed Fixtures

NEC/CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Group E, F, G Class III Class I, Zone 2 IIC Zone 20 IIIC

NEC/CEC: Type 3R, 4, 4X IP66/IP67 Simultaneous Exposure Suitable for Use in Wet Locations

LED/

ArEA

: NEC

/CEC

EmE

rgEN

Cy

Visit our website at www.emerson.com or contact us at (800) 621-1506. © September 2018

20