mercmaster led generation 3 series luminaires with ......• led l70 reported at 60,000 hours. •...
TRANSCRIPT
Applications• Enclosedandgasketedfixturessuitableforusein:
—Awiderangeofindustrial,chemicalprocessingandotherareaswhereflammablegasesandvaporsorcombustibledustsarepresent
—Marineandwetlocations—Suitabilityincludesusewheretheremaybesimultaneous
exposuretoflammablegasesandvaporsorcombustibledusts
• Typicalapplicationsinclude:—Powerplants—Processingplants—Chemicalplants—Oilrefineries—Wasteandsewagetreatment—Otherareaswheredust,water,dirtandroughusagearea
problem
Features• Providesupto1400lumensilluminationfor90minutesof
emergencylightingwithclearlensor800lumensilluminationfor180minutesofemergencylighting.
• Functionaldiagnostictestself-initiatesevery14daysafterinitialstartup.
• Durationtestisautomaticallyperformedonceperyear.• GreenandRedLEDlightsindicatechargingstatusandprovide
faultwarning.• Simplequickdisconnectconnectordisconnectspowerbetween
LEDsandbatterymanagementmoduletoallowmaintenanceinhazardouslocations.
• Suitableformountingheightsupto14feet.• Choiceofopticsforoptimallightdistributioninavarietyof
applications:TypeI,TypeIII,TypeVorTypeVWide.• Choiceofcolortemperature(CCT):5000Kcoolwhite,4000K
neutralwhiteor3000Kwarmwhite.• Customizetotheapplicationrequirementswiththreedifferent
globeoptions:clearpolycarbonate,diffusedpolycarbonate,andclearglass.
• Sevenstandardmountinghooddesignsallowformountinginanylocation.UsessamemountinghoodsasMercmasterIII.
• RetrofitadaptersforCrouse-Hinds™,KillarkandMercmasterIIhoodsavailable.SeeMercmaster™CHAdapters.
• Hingehashighlipforaddedsafetyduringinstallationandservicing.Hingeandboltconstructionassures360°compressionatallpointsonfixturehousinggasketforpositivesealing.Swingawaydesignofcaptiveboltandnutsimplifiesinstallation.
• Ruggedhousingwithsuperiorthermaldesigntranslatestolongluminairelife.
Mercmaster™ LED Generation 3 Series Luminaires with Emergency Battery BackupEnclosed and Gasketed Fixtures
• Luminairehousinghaswiringcompartmentwithterminalblockseparateforeasywiringaccess.
• Standardscrew-typeterminalblockcanacceptUL/CSA26-10AWGwire.
• Standard6kVsurgeprotection.• Heavyduty,hightemperaturesiliconegaskets.• Photometricdataandelectronicdrawingsavailable
uponrequest.• AmbientTemperature:-20˚Cto+55˚C(-4˚Fto+131˚F)• LEDL70reportedat60,000hours.• Fieldreplaceableglobes,batterymanagementmodule(BMM),
batterypackandLEDdriver.Options• Globeandrefractorguardsavailable,purchaseseparately• Safetycableavailable,purchaseseparately• Drainisavailabletodivertwaterexistinginthe
conduitsystem,purchaseseparately.Standard Materials• Mountinghoodsandbodies:castcopperfree
(4/10of1%max.)aluminum• Gaskets:silicone• Allhardwareandcatchassemblies:stainlesssteel• Globe:polycarbonateorglass• Glassrefractorguard:diecastaluminum
Standard Finishes• Mountinghoods,bodiesandglassrefractorguard:grayepoxy
powdercoatfinish,electrostaticallyappliedforcompleteuniformprotection
Related Products• Mercmaster™LEDGeneration3Luminaries• Mercmaster™LEDLowProfileLuminaires• Mercmaster™LEDMountingAdapters
MLGL
NEC/CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Group E, F, G Class III Class I, Zone 2 IIC Zone 20 IIIC
NEC/CEC: Type 3R, 4, 4X IP66/IP67 Simultaneous Exposure Suitable for Use in Wet Locations
Standard ModeNominal Lumens HID Equivalent
Emergency ModeNominal Lumens Model Number
3500 70-100W1450 MLGL3H800 MLGL3E
5500 100-150W1450 MLGL5H800 MLGL5E
Nominal lumen value for 5000K, clear glass globe Type V. Detailed lumen information is provided in tables.
Killark is a registered trademark of Hubbell Incorporated Crouse-Hinds is a registered trademarks of Cooper Crouse-Hinds.
NEC/CEC ENClosEd aNd GaskEtEd Class/ZoNE aNd atEX/IEC/NBR IEC ZoNE 2 RatEd — aREa
Visit our website at www.emerson.com or contact us at (800) 621-1506. © December 2018
1
NEC/CEC Certifications and Compliances• ULStandard:UL844;UL1598;UL50E;UL8750;UL60079-0;
UL924• CSAStandard:C22.2No.0-10;C22.2No.94.2-15;
C22.2No.137-18;C22.2No.250.0-08;C22.2No.250.13-14;CSAE60598-1:16
• NEMAANSI/IECStandards:60529• cCSAus:164460,CertificateNumber:70182640
Design Lights™ Consortium• CheckDLCQPLforcurrentlistofproducts.
Mercmaster™ LED Generation 3 Series Luminaires with Emergency Battery BackupEnclosed and Gasketed Fixtures
NEC/CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Group E, F, G Class III Class I, Zone 2 IIC Zone 20 IIIC
NEC/CEC: Type 3R, 4, 4X IP66/IP67 Simultaneous Exposure Suitable for Use in Wet Locations
NEC/
CEC
ENCl
osEd
aNd
Gas
kEtE
d Cl
ass/
ZoNE
aNd
atE
X/IEC
/NBR
IEC
ZoNE
2 R
atEd
— a
REa
Visit our website at www.emerson.com or contact us at (800) 621-1506. © December 2018
2
LED Flexibility and Modular Design
Type I-Longandnarrowdistributionpatterndesignedwithwalkwaysinmind.
Type III-Wallmounteddistributionpatterndesignedwhereyouneedgoodforwardlightprojection.
Type V-Symmetricalcircledistributionpatternidealwhenyouneedevencoverageinalldirections.
Type V Wide-LiketheTypeVdistributionpatternwithmoreverticallumensdesignedtohelpspreadthelightquickerandmoreoutwards.
Choosefromthree color temperatures(CCT):3000K,4000K,and5000KFour light distribution patterns:TypeI,TypeIII,TypeVandTypeVwideforapplicationflexibility.Six mounting hoodsallowonefixturetobeconfiguredforceiling,pendant,stanchion,orwallapplications.Four globes;clearanddiffusedpolycarbonate,clearglassglobe,andprismaticrefractorprovidejusttherightlevelofdiffusion.
Safety Features Type I & Type III Hinge System
12
3
Latch Assembly and Hinge:Captive,stainlesssteellatchassembly(boltandnut)closessecurelywhileprovidingresistancetocorrosiveatmospheres.Swing-awaydesignsimplifieswiringandinstallation.Extrahighhingeprovidesadditionalprotectionagainstaccidentaldriverhousingdisengagementduringinstallationormaintenance.
TypeI&TypeIIIlightdistributionpatternsuseamultiplehingedhousingdesignwhichallowsyoutocorrectlylineupthebeampatterninyourdesireddirection.Byusingoneofthethreeavailablehingesyoucanpositionthefixtureforoptimallightoutput.
Mercmaster™ LED Generation 3 Series Luminaires with Emergency Battery BackupEnclosed and Gasketed Fixtures
NEC/CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Group E, F, G Class III Class I, Zone 2 IIC Zone 20 IIIC
NEC/CEC: Type 3R, 4, 4X IP66/IP67 Simultaneous Exposure Suitable for Use in Wet Locations
Designed for the Environment Quick Disconnect
Watertight Pendant Hood Safety Cable
Field Changeable Duration Setting
Driverhousingdesignincorporatesseparatesectionsfortheterminalblockanddriver.TheefficientthermaldesignensuresreliableheattransferfromtheLEDassemblyoutviatheheatsinkandthecast,epoxypowdercoat,aluminumbody.
SimplequickdisconnectconnectordisconnectspowerbetweenLEDsandbatterymanagementmoduletoallowmaintenanceinhazardouslocations.
NewwatertightpendanthoodprovidesprotectionagainstwateringressintheconduitutilizinganIP68cordgripwith3wireholes4mmindiameter.
Safetycableisslippedaroundthehousingthroughretentionpointsthatarecastedin.Safetycablehasbuiltinloopscombinedwithalockingcarabinertoallowforaquickandsecureinstallation.
Easyfieldchangeabledurationsettingbetween90and180minutes.
NEC/CEC ENClosEd aNd GaskEtEd Class/ZoNE aNd atEX/IEC/NBR IEC ZoNE 2 RatEd — aREa
Visit our website at www.emerson.com or contact us at (800) 621-1506. © December 2018
3
Mercmaster™ LED Family Tree
NEC/CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Group E, F, G Class III Class I, Zone 2 IIC Zone 20 IIIC
NEC/CEC: Type 3R, 4, 4X IP66/IP67 Simultaneous Exposure Suitable for Use in Wet Locations
Glass Globes
VPGL-LED (Clear)
VPGL-GLASS (Clear)
Polycarbonate Globes
VPGL-DIFF (Diffused)
MLGL
See mounting hood section for part numbers.
Mercmaster™ LED Generation 3 Series Luminaires with Emergency Battery BackupEnclosed and Gasketed Fixtures
AdaptersWateright Pendant Hood
Trunnion Mount
Pendant Mount
Pendant Cone
Mount
Ceiling Mount Wall Mount
25° Stanchion Mount
90° Stanchion Mount
Wall and Stanchion
Mount Adapters
Pendant and Ceiling Mount Adapters
KPA-WT KPCT KPA KPCH KPC KPWB KPS KPST
Globe Guards (Optional Accessory)
Emergency Exit Sign (Optional Accessory)
MGU1 EXR400
NEC/
CEC
ENCl
osEd
aNd
Gas
kEtE
d Cl
ass/
ZoNE
aNd
atE
X/IEC
/NBR
IEC
ZoNE
2 R
atEd
— a
REa
Visit our website at www.emerson.com or contact us at (800) 621-1506. © December 2018
4
NEC/CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Group E, F, G Class III Class I, Zone 2 IIC Zone 20 IIIC
NEC/CEC: Type 3R, 4, 4X IP66/IP67 Simultaneous Exposure Suitable for Use in Wet Locations
Orderusingcatalognumberingguidesbeloworselectcatalognumberfromtablesonfollowingpages.
3/4” NPT, 1” NPT and Metric M20 hub entries are not offered in this mounting option For lumen output information, see Lumen Values Table. Guards for the globes are ordered separately. See the Accessories for more information. Only allowed for Type V and Type V wide light distribution. Type I and Type III use a multiple hinge housing. Hub size does not apply to luminaires ordered with adapters. Adapters only certified for cCSAus.
MLG
Series:MLG-Mercmaster™
LEDGeneration3Series
Lumen(nominal):L3-3500L5-5500
HubSize:2-3/4"NPT3-1"NPT4-1-1/4"NPTstanchion5-1-1/2"NPTstanchion6-MetricM20Blank-Ifusingadapteror
nohood
ColorTemperature:C-Cool,5000KN-Neutral,4000KW-Warm,3000K
GlobeMaterial:P-ClearPolycarbonateGlobeD-DiffusedPolycarbonateGlobeG-ClearGlassGlobe
LightDistributionPattern:1-TypeI3-TypeIII5-TypeVW-TypeVWide
Voltage:BU-120-277Vac,50/60Hz;
Mounting:A-PendantB-WatertightPendantC-CeilingD-PendantConeR-90ºStanchionS-25ºStanchionT-TrunnionK-Killark™Adapter
UniversalU-Mercmaster™IIAdapter,
CeilingorPendant
V-Mercmaster™IIAdapter,StanchionorWall
W-WallX-CrouseHinds™Adapter,
CeilingorPendantY-CrouseHinds™Adapter,
StanchionorWallBlank-Nomountinghood
A L3 2 C P 5 BU H
Mercmaster™ LED Generation 3 Series Luminaires with Emergency Battery BackupEnclosed and Gasketed Fixtures
Emergency:H-90MinutesE-180Minutes
NEC/CEC ENClosEd aNd GaskEtEd Class/ZoNE aNd atEX/IEC/NBR IEC ZoNE 2 RatEd — aREa
Visit our website at www.emerson.com or contact us at (800) 621-1506. © December 2018
5
Lumen Values Table
Lumen Output (Efficacy) for Clear Polycarbonate Globe
MLGL3H MLGL5H
TypeI 5000KCCT,70CRI 3200(107) 4800(104)
TypeIII 5000KCCT,70CRI 3500(117) 5200(113)
TypeV 5000KCCT,70CRI 3800(127) 5700(124)
TypeVWide 5000KCCT,70CRI 3600(119) 6000(129)
TypeI 4000KCCT,80CRI 3000(100) 4200(91)
TypeIII 4000KCCT,80CRI 3000(100) 4600(100)
TypeV 4000KCCT,80CRI 3300(110) 5000(109)
TypeVWide 4000KCCT,80CRI 2900(97) 4800(105)
TypeI 3000KCCT,80CRI 2600(87) 3800(83)
TypeIII 3000KCCT,80CRI 2800(93) 4100(89)
TypeV 3000KCCT,80CRI 3000(100) 4500(98)
TypeVWide 3000KCCT,80CRI 2900(96) 4400(94)
Lumen Output (Efficacy) for Clear Glass Globe
MLGL3H MLGL5H
TypeI 5000KCCT,70CRI 3500(117) 5300(115)
TypeIII 5000KCCT,70CRI 3700(123) 5400(117)
TypeV 5000KCCT,70CRI 4000(133) 6000(130)
TypeVWide 5000KCCT,70CRI 3600(120) 5400(117)
TypeI 4000KCCT,80CRI 3100(103) 4600(100)
TypeIII 4000KCCT,80CRI 3200(107) 4800(104)
TypeV 4000KCCT,80CRI 3600(120) 5300(115)
TypeVWide 4000KCCT,80CRI 3200(107) 4800(104)
TypeI 3000KCCT,80CRI 2800(93) 4200(91)
TypeIII 3000KCCT,80CRI 3100(102) 4400(96)
TypeV 3000KCCT,80CRI 3100(102) 4800(104)
TypeVWide 3000KCCT,80CRI 3100(101) 4600(99)
Mercmaster™ LED Generation 3 Series Luminaires with Emergency Battery BackupEnclosed and Gasketed Fixtures
NEC/CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Group E, F, G Class III Class I, Zone 2 IIC Zone 20 IIIC
NEC/CEC: Type 3R, 4, 4X IP66/IP67 Simultaneous Exposure Suitable for Use in Wet Locations
NEC/
CEC
ENCl
osEd
aNd
Gas
kEtE
d Cl
ass/
ZoNE
aNd
atE
X/IEC
/NBR
IEC
ZoNE
2 R
atEd
— a
REa
Visit our website at www.emerson.com or contact us at (800) 621-1506. © December 2018
6
Mercmaster™ LED Generation 3 Series Luminaires with Emergency Battery BackupEnclosed and Gasketed Fixtures
NEC/CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Group E, F, G Class III Class I, Zone 2 IIC Zone 20 IIIC
NEC/CEC: Type 3R, 4, 4X IP66/IP67 Simultaneous Exposure Suitable for Use in Wet Locations
90 Minute Emergency Mode
ModelLumens
Polycarbonate Clear Globe Polycarbonate Diffused Globe Glass Clear Globe
MLGL3H5000KCCT,70CRI 1400 1350 1450
MLGL5H
MLGL3H4000KCCT,80CRI 1280 1230 1330
MLGL5H
MLGL3H3000KCCT,80CRI 1100 1150 1200
MLGL5H
All lumen values are typical (tolerance +/-10%). Diffused polycarbonate globe can be used with Type I, III and V wide. Refer to photometric files for lumen output information.
Lumen Output (Efficacy) for Diffused Polycarbonate Globe
MLGL3 MLGL5
TypeI 5000KCCT,70CRI 3200(108) 4900(107)
TypeIII 5000KCCT,70CRI 3300(112) 5100(110)
TypeV 5000KCCT,70CRI 3700(123) 5500(120)
TypeVWide 5000KCCT,70CRI 3400(113) 5100(110)
TypeI 4000KCCT,80CRI 2900(95) 4400(94)
TypeIII 4000KCCT,80CRI 3000(101) 4600(100)
TypeV 4000KCCT,80CRI 3200(107) 4800(104)
TypeVWide 4000KCCT,80CRI 3000(101) 4600(100)
TypeI 3000KCCT,80CRI 2700(87) 4000(85)
TypeIII 3000KCCT,80CRI 2800(92) 4200(91)
TypeV 3000KCCT,80CRI 2900(97) 4400(96)
TypeVWide 3000KCCT,80CRI 2800(91) 4200(90)
NEC/CEC ENClosEd aNd GaskEtEd Class/ZoNE aNd atEX/IEC/NBR IEC ZoNE 2 RatEd — aREa
Visit our website at www.emerson.com or contact us at (800) 621-1506. © December 2018
7
Mercmaster™ LED Generation 3 Series Luminaires with Emergency Battery BackupEnclosed and Gasketed Fixtures
LED Signals
Color Timing Description
Green 1secON:1secOFF Normalchargingok,Batterynotyetfullycharged,Nofaultdetected,Testingok
Green 0.25secON:0.25secOFF Functional/DurationSelf-Teston-going
Green SteadyON Chargingok,Batteryfullycharged,Nofaultdetected,Testingok
Red 1secON:1secOFF
Faultcondition.Installationissue.Batteryisreverse,notconnectedorshorted.Functionaltestfailure,fullduration
testfailure
LEDIndicatorsOFF,LEDArrayON LEDIndicatorLights(RedandGreen)OFF NoAC,EmergencymodeON
Automatic Testing System (ATS)
Functional Full Duration
Startswithin24to45hoursaftertheinitialpowerupofthemodule Startswithin5to26daysaftertheinitialpowerofthemodule
Occursevery14daysaftertheinitialaforementionedfunctionaltest Occursevery364daysaftertheinitialaforementionedfunctionaltest
Lastsfor5minutes Lastsforthefulldurationoftheratedemergencyperiod
Atthecompletionoffunctionalandfulldurationtests,LEDindicatorwilldisplaythestatusoftheemergencyluminairewhenACispresent
LEDIndicator LEDArray
NEC/CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Group E, F, G Class III Class I, Zone 2 IIC Zone 20 IIIC
NEC/CEC: Type 3R, 4, 4X IP66/IP67 Simultaneous Exposure Suitable for Use in Wet Locations
NEC/
CEC
ENCl
osEd
aNd
Gas
kEtE
d Cl
ass/
ZoNE
aNd
atE
X/IEC
/NBR
IEC
ZoNE
2 R
atEd
— a
REa
Visit our website at www.emerson.com or contact us at (800) 621-1506. © December 2018
8
Mercmaster™ LED Generation 3 Series Luminaires with Emergency Battery BackupEnclosed and Gasketed Fixtures
Electrical Ratings
Model Number Voltage Input Power Input Current (amp) Power Factor THD
MLGL3H BU
120Vac 30 0.26
>0.9 <20%
277Vac 30 0.12
MLGL5H BU
120Vac 46 0.39
>0.9 <20%
277Vac 46 0.17
NEC/CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Group E, F, G Class III Class I, Zone 2 IIC Zone 20 IIIC
NEC/CEC: Type 3R, 4, 4X IP66/IP67 Simultaneous Exposure Suitable for Use in Wet Locations
All values are typical (tolerance +/-10%).
NEC/CEC ENClosEd aNd GaskEtEd Class/ZoNE aNd atEX/IEC/NBR IEC ZoNE 2 RatEd — aREa
Visit our website at www.emerson.com or contact us at (800) 621-1506. © December 2018
9
Mercmaster™ LED Generation 3 Series Luminaires with Emergency Battery BackupEnclosed and Gasketed Fixtures
Technical Data
Model Number
Max. Ambient Temperature
°C (°F)Min. Supply Wire
°C (°F)
Class I Division 2 Groups A, B, C
and DClass I, Zone 2,
Group IIC
Class II, Division 1, Groups E, F
and GZone 21,
Group IIIC
Class I, Division 2 & Class II, Division 1
MLGL340(104)
90(194)T5 T5 T6 T6 T5
55(131) T5 T5 T6 T6 T5
MLGL540(104)
90(194)T5 T5 T6 T6 T4A
55(131) T5 T5 T6 T6 T4A
NEC/CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Group E, F, G Class III Class I, Zone 2 IIC Zone 20 IIIC
NEC/CEC: Type 3R, 4, 4X IP66/IP67 Simultaneous Exposure Suitable for Use in Wet Locations
NEC/
CEC
ENCl
osEd
aNd
Gas
kEtE
d Cl
ass/
ZoNE
aNd
atE
X/IEC
/NBR
IEC
ZoNE
2 R
atEd
— a
REa
Visit our website at www.emerson.com or contact us at (800) 621-1506. © December 2018
10
“T” Numbers Represent the Maximum Internal Temperature or Maximum Surface Temperature
NEC/CEC
“T” # T1 350 325 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6
Temp.RangeºC(ºF)
351–450(664–842)
326–350(619–662)
301–325(574–617)
281–300(538–572)
261–280(502–536)
231–260(448–500)
216–230(421–446)
201–215(394–419)
181–200(358–392)
166–180(547–842)
161–165(322–329)
136–160(277–320)
121–135(250–275)
101–120(214–248)
86–100(187–212)
85(185)
T numbers represent the maximum internal temperature for Class I, Division 2 and Class I, Zone 2 locations designated by the NEC.T numbers represent the maximum surface temperature under a dust blanket for Class II, Division 1 and Class I, Zone 2 as designated by the NEC or Zone 2
(Gas) and 22 (Dust) locations as designated by the IEC.
Mercmaster™ LED Generation 3 Series Luminaires with Emergency Battery BackupEnclosed and Gasketed Fixtures
Catalog Number for Driver Housing and Globe
Lumen Level CCT Optics
Clear Polycarbonate Globe
Polycarbonate Diffused Globe
Clear Glass Globe
90 Min 180 Min 90 Min 180 Min 90 Min 180 Min
3K 5000K
TypeI MLGL3CP1BUH MLGL3CP1BUE MLGL3CP1BUH MLGL3CP1BUE MLGL3CG1BUH MLGL3CG1BUE
TypeIII MLGL3CP3BUH MLGL3CP3BUE MLGL3CP3BUH MLGL3CP3BUE MLGL3CG3BUH MLGL3CG3BUE
TypeV MLGL3CP5BUH MLGL3CP5BUE MLGL3CP5BUH MLGL3CP5BUE MLGL3CG5BUH MLGL3CG5BUE
TypeVWide
MLGL3CPWBUH MLGL3CPWBUE MLGL3CPWBUH MLGL3CPWBUE MLGL3CGWBUH MLGL3CGWBUE
5K 5000K
TypeI MLGL5CP1BUH MLGL5CP1BUE MLGL5CP1BUH MLGL5CP1BUE MLGL5CG1BUH MLGL5CG1BUE
TypeIII MLGL5CP3BUH MLGL5CP3BUE MLGL5CP3BUH MLGL5CP3BUE MLGL5CG3BUH MLGL5CG3BUE
TypeV MLGL5CP5BUH MLGL5CP5BUE MLGL5CP5BUH MLGL5CP5BUE MLGL5CG5BUH MLGL5CG5BUE
TypeVWide
MLGL5CPWBUH MLGL5CPWBUE MLGL5CPWBUH MLGL5CPWBUE MLGL5CGWBUH MLGL5CGWBUE
For other CCT options, change the 6th digit in part number from “C” to “W” for Warm 3000K CCT or “N” for Neutral 4000K CCT.Example: MLGL7CP5BUH to “W” for Warm, MLGL7WP5BUH.
Guards are available. See following pages for accessory ordering information.
NEC/CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Group E, F, G Class III Class I, Zone 2 IIC Zone 20 IIIC
NEC/CEC: Type 3R, 4, 4X IP66/IP67 Simultaneous Exposure Suitable for Use in Wet Locations
NEC/CEC ENClosEd aNd GaskEtEd Class/ZoNE aNd atEX/IEC/NBR IEC ZoNE 2 RatEd — aREa
Visit our website at www.emerson.com or contact us at (800) 621-1506. © December 2018
11
Mounting Hoods
Description Weight in kg (lbs) Hub Size Catalog Number
Pendant
OneHub,RigidMounting1.0(2.3)
3/4 KPA-75
1 KPA-100
M20 KPA-M20
Watertight Pendant Hood
OneHub3/4 KPA-75-WT
1 KPA-100-WT
Pendant Cone
OneHub,RigidMounting1.1(2.5)
3/4 KPCH-75
1 KPCH-100
M20 KPCH-M20
Trunnion
FiveHubs,FourClose-UpPlugs 3/4 KPCT-75
1 KPCT-100
Ceiling
FiveHubs,FourClose-UpPlugs1.4(3.0)
3/4 KPC-75
1 KPC-100
M20 KPC-M20
Wall
FiveHubs,FourClose-UpPlugs1.8(4.0)
3/4 KPWB-75
1 KPWB-100
M20 KPWB-M20
25° Stanchion
OneHub1.5(3.3)
1-1/4 KPS-125
1-1/2 KPS-150
90° Stanchion
OneHub1.7(3.8)
1-1/4 KPST-125
1-1/2 KPST-150
Mercmaster™ LED Generation 3 Series Luminaires with Emergency Battery BackupEnclosed and Gasketed Fixtures
NEC/CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Group E, F, G Class III Class I, Zone 2 IIC Zone 20 IIIC
NEC/CEC: Type 3R, 4, 4X IP66/IP67 Simultaneous Exposure Suitable for Use in Wet Locations
NEC/
CEC
ENCl
osEd
aNd
Gas
kEtE
d Cl
ass/
ZoNE
aNd
atE
X/IEC
/NBR
IEC
ZoNE
2 R
atEd
— a
REa
Visit our website at www.emerson.com or contact us at (800) 621-1506. © December 2018
12
Accessories and Replacement Parts
Description Weight in kg (lbs) Catalog Number
Globes and Gaskets
ClearGlobe(polycarbonate)0.2(0.5)
VPGL-LED
DiffusedGlobe(polycarbonate)0.2(0.5)
VPGL-DIFF
GlassGlobe—Clear0.8(1.7)
VPGL-GLASS
Mercmaster™ LED Generation 3 Series Luminaires with Emergency Battery BackupEnclosed and Gasketed Fixtures
NEC/CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Group E, F, G Class III Class I, Zone 2 IIC Zone 20 IIIC
NEC/CEC: Type 3R, 4, 4X IP66/IP67 Simultaneous Exposure Suitable for Use in Wet Locations
Mounting Hood Adapters
Manufacturer Installed Mounting Hood Appleton Adapter Catalog Number
Crouse-Hinds™
Champ
APM2/3-PendantCM2/3-Ceiling
HPM2-FlexiblePendantMMADCHVS
Appleton™Mercmaster™II
LPA75/100-PendantLPC75/100-Ceiling MMADIIS
Crouse-Hinds™
Champ
TWM2/3-WallJM5-25°AngleStanchionPM5-90°StraightStanchion
MMADCHVA
Appleton™Mercmaster™II
LPWB75,LPWB100-WallLPS125,LPS150-25°AngleStanchion MMADIIA
Killark™
VMX2B,VMX3B,VMX6B,VMX7B,VMX9B-CeilingVMA2B,VMA3B-Pendant
VMD4B,VMD5B,VMS4B,VMS5B-StanchionVMB2B,VMB3B-Wall
VMC2B,VMC3B-PendantCone
MMADKVA
NEC/CEC ENClosEd aNd GaskEtEd Class/ZoNE aNd atEX/IEC/NBR IEC ZoNE 2 RatEd — aREa
Visit our website at www.emerson.com or contact us at (800) 621-1506. © December 2018
13
Replacement Drivers
Voltage Driver Wattage Luminaire ModelConstant Current
Settings Catalog Number
BU50Watt MLGL3
500mA APMS050C135UD50
BH 500mA APMS050C135HD50
BU50Watt MLGL5
780mA APMS050C135UD78
BH 780mA APMS050C135HD78
Mercmaster™ LED Generation 3 Series Luminaires with Emergency Battery BackupEnclosed and Gasketed Fixtures
Luminaire Weights
Model Number Weight in kg (lbs)
MLGL3H 12.4(15.35)
MLGL5H 12.4(15.35)
NEC/CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Group E, F, G Class III Class I, Zone 2 IIC Zone 20 IIIC
NEC/CEC: Type 3R, 4, 4X IP66/IP67 Simultaneous Exposure Suitable for Use in Wet Locations
Accessories and Replacement Parts
Description Weight in kg (lbs) Catalog Number
Globe Guards and Safety Chain
GlobeGuard0.2(0.4) MGU1
SafetyCable0.2(0.4)
LEDSC
Exit Sign
EmergencyExitsign EXR-400
Drain Plug
3”long,1/2”tradesizedrainassemblyusedtodivertwaterexistingintheconduitsystem
0.4(0.9)LEDDR3
Replacement Battery Pack BPMLLED
Replacement Battery Management Module BMMLLED
Replacement Fuse (Emergency system) MLF3
NEC/
CEC
ENCl
osEd
aNd
Gas
kEtE
d Cl
ass/
ZoNE
aNd
atE
X/IEC
/NBR
IEC
ZoNE
2 R
atEd
— a
REa
Visit our website at www.emerson.com or contact us at (800) 621-1506. © December 2018
14
Dimensional Drawings
MLGL3H to MLGL5H
Driver Housing
209.6 mm [8.25 in]
224.3 mm [8.83 in]
321.9 mm [12.67 in]
Ø374.6 mm [14.75 in]
232.3 mm [9.15 in]
383.6 mm [15.10 in]
415.2 mm [16.35 in]
25° Ø374.6 mm [14.75 in]
248.6 mm [9.79 in]
434.8 mm [17.12 in]
469.0 mm [18.46 in]
Ø374.6 mm [14.75 in]
257.0 mm [10.12 in]
103.1 mm [4.06 in]
Ø374.6 mm [14.75 in]
Ø374.6 mm [14.75 in]
Ø374.6 mm [14.75 in] 236.7 mm
[9.32 in]
198.1 mm [7.80 in]
Ø375.0 mm [14.76 in]
Ø372.9 mm [14.68 in]
Ø374.7 mm [14.75 in]
257.6 mm [10.14 in]
25
Watertight Pendant
245.6 mm [9.67 in]
387.0 mm [15.23 in]
274.3 mm [10.80 in]
415.7 mm [16.36 in]
203.6 mm [8.01 in]
345.8 mm [13.61 in]
339.7 mm [13.37 in]
339.7 mm [13.37 in]
LITTLE PRIMO
BIG PRIMO
LOW PROFILE 1.5
Ø374.7 mm [14.75 in]
Ø374.7 mm [14.75 in]
Ø374.7 mm [14.75 in]
Ø374.7 mm [14.75 in]
Pendant
209.6 mm [8.25 in]
224.3 mm [8.83 in]
321.9 mm [12.67 in]
Ø374.6 mm [14.75 in]
232.3 mm [9.15 in]
383.6 mm [15.10 in]
415.2 mm [16.35 in]
25° Ø374.6 mm [14.75 in]
248.6 mm [9.79 in]
434.8 mm [17.12 in]
469.0 mm [18.46 in]
Ø374.6 mm [14.75 in]
257.0 mm [10.12 in]
103.1 mm [4.06 in]
Ø374.6 mm [14.75 in]
Ø374.6 mm [14.75 in]
Ø374.6 mm [14.75 in] 236.7 mm
[9.32 in]
198.1 mm [7.80 in]
Ø375.0 mm [14.76 in]
Ø372.9 mm [14.68 in]
Ø374.7 mm [14.75 in]
257.6 mm [10.14 in]
25
Mercmaster™ LED Generation 3 Series Luminaires with Emergency Battery BackupEnclosed and Gasketed Fixtures
NEC/CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Group E, F, G Class III Class I, Zone 2 IIC Zone 20 IIIC
NEC/CEC: Type 3R, 4, 4X IP66/IP67 Simultaneous Exposure Suitable for Use in Wet Locations
NEC/CEC ENClosEd aNd GaskEtEd Class/ZoNE aNd atEX/IEC/NBR IEC ZoNE 2 RatEd — aREa
Visit our website at www.emerson.com or contact us at (800) 621-1506. © December 2018
15
Dimensional Drawings
MLGL3H to MLGL5H
Pendant Cone
209.6 mm [8.25 in]
224.3 mm [8.83 in]
321.9 mm [12.67 in]
Ø374.6 mm [14.75 in]
232.3 mm [9.15 in]
383.6 mm [15.10 in]
415.2 mm [16.35 in]
25° Ø374.6 mm [14.75 in]
248.6 mm [9.79 in]
434.8 mm [17.12 in]
469.0 mm [18.46 in]
Ø374.6 mm [14.75 in]
257.0 mm [10.12 in]
103.1 mm [4.06 in]
Ø374.6 mm [14.75 in]
Ø374.6 mm [14.75 in]
Ø374.6 mm [14.75 in] 236.7 mm
[9.32 in]
198.1 mm [7.80 in]
Ø375.0 mm [14.76 in]
Ø372.9 mm [14.68 in]
Ø374.7 mm [14.75 in]
257.6 mm [10.14 in]
25
Ceiling
209.6 mm [8.25 in]
224.3 mm [8.83 in]
321.9 mm [12.67 in]
Ø374.6 mm [14.75 in]
232.3 mm [9.15 in]
383.6 mm [15.10 in]
415.2 mm [16.35 in]
25° Ø374.6 mm [14.75 in]
248.6 mm [9.79 in]
434.8 mm [17.12 in]
469.0 mm [18.46 in]
Ø374.6 mm [14.75 in]
257.0 mm [10.12 in]
103.1 mm [4.06 in]
Ø374.6 mm [14.75 in]
Ø374.6 mm [14.75 in]
Ø374.6 mm [14.75 in] 236.7 mm
[9.32 in]
198.1 mm [7.80 in]
Ø375.0 mm [14.76 in]
Ø372.9 mm [14.68 in]
Ø374.7 mm [14.75 in]
257.6 mm [10.14 in]
25
Wall Mount
209.6 mm [8.25 in]
224.3 mm [8.83 in]
321.9 mm [12.67 in]
Ø374.6 mm [14.75 in]
232.3 mm [9.15 in]
383.6 mm [15.10 in]
415.2 mm [16.35 in]
25° Ø374.6 mm [14.75 in]
248.6 mm [9.79 in]
434.8 mm [17.12 in]
469.0 mm [18.46 in]
Ø374.6 mm [14.75 in]
257.0 mm [10.12 in]
103.1 mm [4.06 in]
Ø374.6 mm [14.75 in]
Ø374.6 mm [14.75 in]
Ø374.6 mm [14.75 in] 236.7 mm
[9.32 in]
198.1 mm [7.80 in]
Ø375.0 mm [14.76 in]
Ø372.9 mm [14.68 in]
Ø374.7 mm [14.75 in]
257.6 mm [10.14 in]
25
Mercmaster™ LED Generation 3 Series Luminaires with Emergency Battery BackupEnclosed and Gasketed Fixtures
NEC/CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Group E, F, G Class III Class I, Zone 2 IIC Zone 20 IIIC
NEC/CEC: Type 3R, 4, 4X IP66/IP67 Simultaneous Exposure Suitable for Use in Wet Locations
NEC/
CEC
ENCl
osEd
aNd
Gas
kEtE
d Cl
ass/
ZoNE
aNd
atE
X/IEC
/NBR
IEC
ZoNE
2 R
atEd
— a
REa
Visit our website at www.emerson.com or contact us at (800) 621-1506. © December 2018
16
Dimensional Drawings
MLGL3H to MLGL5H
Trunnion Mount
Luminaire with Small Heat Sink
462.3 mm [18.20 in]
501.5 mm [19.74 in]
502.5 mm [19.78 in]
478.2 mm [18.83 in]
336.9 mm [13.26 in]
[14.04 in]356.5 mm
Ø374.7 mm [14.75 in]
Ø374.7 mm [14.75 in]
Ø374.7 mm [14.75 in]
Ø374.7 mm [14.75 in]
448.2 mm [17.65 in]
306.9 mm [12.08 in]
435.2 mm [17.13 in]
313.0 mm [12.32 in]
480.2 mm [18.91 in]
480.3 mm [18.91 in]
Ø374.7 mm [14.75 in]
Ø374.7 mm [14.75 in]
Ø374.7 mm [14.75 in]
Ø374.7 mm [14.75 in]
Luminaire with Large Heat Sink
25 Degree Stanchion
209.6 mm [8.25 in]
224.3 mm [8.83 in]
321.9 mm [12.67 in]
Ø374.6 mm [14.75 in]
232.3 mm [9.15 in]
383.6 mm [15.10 in]
415.2 mm [16.35 in]
25° Ø374.6 mm [14.75 in]
248.6 mm [9.79 in]
434.8 mm [17.12 in]
469.0 mm [18.46 in]
Ø374.6 mm [14.75 in]
257.0 mm [10.12 in]
103.1 mm [4.06 in]
Ø374.6 mm [14.75 in]
Ø374.6 mm [14.75 in]
Ø374.6 mm [14.75 in] 236.7 mm
[9.32 in]
198.1 mm [7.80 in]
Ø375.0 mm [14.76 in]
Ø372.9 mm [14.68 in]
Ø374.7 mm [14.75 in]
257.6 mm [10.14 in]
25
90 Degree Stanchion
209.6 mm [8.25 in]
224.3 mm [8.83 in]
321.9 mm [12.67 in]
Ø374.6 mm [14.75 in]
232.3 mm [9.15 in]
383.6 mm [15.10 in]
415.2 mm [16.35 in]
25° Ø374.6 mm [14.75 in]
248.6 mm [9.79 in]
434.8 mm [17.12 in]
469.0 mm [18.46 in]
Ø374.6 mm [14.75 in]
257.0 mm [10.12 in]
103.1 mm [4.06 in]
Ø374.6 mm [14.75 in]
Ø374.6 mm [14.75 in]
Ø374.6 mm [14.75 in] 236.7 mm
[9.32 in]
198.1 mm [7.80 in]
Ø375.0 mm [14.76 in]
Ø372.9 mm [14.68 in]
Ø374.7 mm [14.75 in]
257.6 mm [10.14 in]
25
Mercmaster™ LED Generation 3 Series Luminaires with Emergency Battery BackupEnclosed and Gasketed Fixtures
NEC/CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Group E, F, G Class III Class I, Zone 2 IIC Zone 20 IIIC
NEC/CEC: Type 3R, 4, 4X IP66/IP67 Simultaneous Exposure Suitable for Use in Wet Locations
NEC/CEC ENClosEd aNd GaskEtEd Class/ZoNE aNd atEX/IEC/NBR IEC ZoNE 2 RatEd — aREa
Visit our website at www.emerson.com or contact us at (800) 621-1506. © December 2018
17
Photometric Data — DATA SHOWN IS ABSOLUTEType V, Clear Polycarbonate 5000K CCTREPORT NUMBER: MLLED2CP5BUH+EMR
Luminaire Lumens 1,404
POLAR CANDELA DISTRIBUTION ISOFOOT CANDLE PLOT ZONAL LUMEN SUMMARY
180° 170° 160° 150° 140°
130°
120°
110°
100°
90°
80°
70°
60°
525
630
420
315
105
210
315
420
525
630
105
210
0
50°
40°30°20°10°0°
- Max CD: 145°H- 45° H- 67.5° H
- 22.5° H
- 90° H- 0° H
2
2
3
1 0
1
0
1
2
3
2 fc5 fc
Point of Max FC: 3.96
1 fc
20 fc30 fc
2.5 fc0.1 fc
1 fc50% Max Cd
0.5 fc
5 fc0.2 fc
1 2 3
House Side
Street Side
Zone Lumens % Luminaire0-30 407.0 29%0-40 763.6 54.4%0-60 1,388.0 98.8%60-90 16.4 1.2%70-100 3.5 0.3%90-120 0.1 0%0-90 1,404.4 100%90-180 0.1 0%0-180 1,404.5 100%
LUMENS PER ZONEZone Lumens % Total Zone Lumens % Total0-10 44.3 3.2% 90-100 0.1 0%10-20 130.2 9.3% 100-110 0 0%20-30 232.5 16.6% 110-120 0 0%30-40 356.6 25.4% 120-130 0 0%40-50 424.6 30.2% 130-140 0 0%50-60 199.9 14.2% 140-150 0 0%60-70 12.9 0.9% 150-160 0 0%70-80 2.4 0.2% 160-170 0 0%80-90 1.1 0.1% 170-180 0 0%
Type V, Diffused Polycarbonate 5000K CCTREPORT NUMBER: MLLED2CD5BUH+EMR
Luminaire Lumens 1,369
POLAR CANDELA DISTRIBUTION ISOFOOT CANDLE PLOT ZONAL LUMEN SUMMARY
180° 170° 160° 150° 140°
130°
120°
110°
100°
90°
80°
70°
60°
433
520
347
260
87
173
260
347
433
520
87
173
0
50°
40°30°20°10°0°
- Max CD: 145°H- 45° H- 67.5° H
- 22.5° H
- 90° H- 0° H
2
2
3
1 0
1
0
1
2
3
2 fc5 fc
Point of Max FC: 4.36
1 fc
20 fc30 fc
2.5 fc0.1 fc
1 fc50% Max Cd
0.5 fc
5 fc0.2 fc
1 2 3
House Side
Street Side
Zone Lumens % Luminaire0-30 395.3 28.9%0-40 702.3 51.3%0-60 1,231.5 89.9%60-90 126.7 9.2%70-100 44.8 3.3%90-120 10.6 0.8%0-90 1,358.2 99.2%90-180 11.1 0.8%0-180 1,369.3 100%
LUMENS PER ZONEZone Lumens % Total Zone Lumens % Total0-10 43.5 3.2% 90-100 4.2 0.3%10-20 129.9 9.5% 100-110 4.7 0.3%20-30 221.9 16.2% 110-120 1.8 0.1%30-40 307.0 22.4% 120-130 0.5 0%40-50 321.3 23.5% 130-140 0 0%50-60 208.0 15.2% 140-150 0 0%60-70 86.0 6.3% 150-160 0 0%70-80 31.5 2.3% 160-170 0 0%80-90 9.1 0.7% 170-180 0 0%
Mercmaster™ LED Generation 3 Series Luminaires with Emergency Battery BackupEnclosed and Gasketed Fixtures
NEC/CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Group E, F, G Class III Class I, Zone 2 IIC Zone 20 IIIC
NEC/CEC: Type 3R, 4, 4X IP66/IP67 Simultaneous Exposure Suitable for Use in Wet Locations
LED/
ArEA
: NEC
/CEC
EmE
rgEN
Cy
Visit our website at www.emerson.com or contact us at (800) 621-1506. © September 2018
18
Photometric Data — DATA SHOWN IS ABSOLUTEType V, Clear Glass 5000K CCTREPORT NUMBER: MLLED2CG5BUH+EMR
Luminaire Lumens 1,460
POLAR CANDELA DISTRIBUTION ISOFOOT CANDLE PLOT ZONAL LUMEN SUMMARY
180° 170° 160° 150° 140°
130°
120°
110°
100°
90°
80°
70°
60°
558
670
447
335
112
223
335
447
558
670
112
223
0
50°
40°30°20°10°0°
- Max CD: 145°H- 45° H- 67.5° H
- 22.5° H
- 90° H- 0° H
2
2
3
1 0
1
0
1
2
3
2 fc5 fc
Point of Max FC: 3.76
1 fc
20 fc30 fc
2.5 fc0.1 fc
1 fc50% Max Cd
0.5 fc
5 fc0.2 fc
1 2 3
House Side
Street Side
Zone Lumens % Luminaire0-30 420.1 28.8%0-40 792.8 54.3%0-60 1,443.4 98.8%60-90 16.8 1.1%70-100 3.0 0.2%90-120 0.1 0%0-90 1,460.2 100%90-180 0.1 0%0-180 1,460.2 100%
LUMENS PER ZONEZone Lumens % Total Zone Lumens % Total0-10 44.3 3.0% 90-100 0.1 0%10-20 133.9 9.2% 100-110 0 0%20-30 242.0 16.6% 110-120 0 0%30-40 372.6 25.5% 120-130 0 0%40-50 444.7 30.5% 130-140 0 0%50-60 205.9 14.1% 140-150 0 0%60-70 13.8 0.9% 150-160 0 0%70-80 2.1 0.1% 160-170 0 0%80-90 0.8 0.1% 170-180 0 0%
Type V, Clear Polycarbonate 4000K CCTREPORT NUMBER: MLLED4NG5BUH+EMR
Luminaire Lumens 1,330
POLAR CANDELA DISTRIBUTION ISOFOOT CANDLE PLOT ZONAL LUMEN SUMMARY
180° 170° 160° 150° 140°
130°
120°
110°
100°
90°
80°
70°
60°
508
610
407
305
102
203
305
407
508
610
102
203
0
50°
40°30°20°10°0°
- 45° H- 67.5° H
- 22.5° H- 90° H- 0° H
2
2
3
1 0
1
0
1
2
3
2 fc5 fc
Point of Max FC: 3.40
1 fc
20 fc30 fc
2.5 fc0.1 fc
1 fc50% Max Cd
0.5 fc
5 fc0.2 fc
1 2 3
House Side
Street Side
Zone Lumens % Luminaire0-30 392.5 29.5%0-40 733.5 55.1%0-60 1,315.4 98.9%60-90 15.0 1.1%70-100 2.6 0.2%90-120 0 0%0-90 1,330.4 100%90-180 0 0%0-180 1,330.4 100%
LUMENS PER ZONEZone Lumens % Total Zone Lumens % Total0-10 41.9 3.1% 90-100 0 0%10-20 125.8 9.5% 100-110 0 0%20-30 224.8 16.9% 110-120 0 0%30-40 341.0 25.6% 120-130 0 0%40-50 399.6 30.0% 130-140 0 0%50-60 182.3 13.7% 140-150 0 0%60-70 12.4 0.9% 150-160 0 0%70-80 1.9 0.1% 160-170 0 0%80-90 0.7 0.1% 170-180 0 0%
Mercmaster™ LED Generation 3 Series Luminaires with Emergency Battery BackupEnclosed and Gasketed Fixtures
NEC/CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Group E, F, G Class III Class I, Zone 2 IIC Zone 20 IIIC
NEC/CEC: Type 3R, 4, 4X IP66/IP67 Simultaneous Exposure Suitable for Use in Wet Locations
LED/ArEA: NEC/CEC EmErgENCy
Visit our website at www.emerson.com or contact us at (800) 621-1506. © September 2018
19
Photometric Data — DATA SHOWN IS ABSOLUTEType V, Clear Glass 4000K CCTREPORT NUMBER: MLLED4WG5BUH+EMR
Luminaire Lumens 1,207
POLAR CANDELA DISTRIBUTION ISOFOOT CANDLE PLOT ZONAL LUMEN SUMMARY
180° 170° 160° 150° 140°
130°
120°
110°
100°
90°
80°
70°
60°
458
550
367
275
92
183
275
367
458
550
92
183
0
50°
40°30°20°10°0°
- 45° H- 67.5° H
- 22.5° H
- 90° H- 0° H- Max CD: 145°H
2
2
3
1 0
1
0
1
2
3
2 fc5 fc
Point of Max FC: 3.06
1 fc
20 fc30 fc
2.5 fc0.1 fc
1 fc50% Max Cd
0.5 fc
5 fc0.2 fc
1 2 3
House Side
Street Side
Zone Lumens % Luminaire0-30 355.1 29.4%0-40 659.9 54.6%0-60 1,193.4 98.8%60-90 14.4 1.2%70-100 2.4 0.2%90-120 0 0%0-90 1,207.8 100%90-180 0 0%0-180 1,207.8 100%
LUMENS PER ZONEZone Lumens % Total Zone Lumens % Total0-10 38.1 3.2% 90-100 0 0%10-20 114.1 9.4% 100-110 0 0%20-30 202.9 16.8% 110-120 0 0%30-40 304.8 25.2% 120-130 0 0%40-50 360.5 29.8% 130-140 0 0%50-60 173.0 14.3% 140-150 0 0%60-70 12.0 1.0% 150-160 0 0%70-80 1.7 0.1% 160-170 0 0%80-90 0.7 0.1% 170-180 0 0%
Mercmaster™ LED Generation 3 Series Luminaires with Emergency Battery BackupEnclosed and Gasketed Fixtures
NEC/CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Group E, F, G Class III Class I, Zone 2 IIC Zone 20 IIIC
NEC/CEC: Type 3R, 4, 4X IP66/IP67 Simultaneous Exposure Suitable for Use in Wet Locations
LED/
ArEA
: NEC
/CEC
EmE
rgEN
Cy
Visit our website at www.emerson.com or contact us at (800) 621-1506. © September 2018
20