115 Walgreen Road, R.R.3. Carp, ON K0A 1L0 | T. 613-836-2184 | F. 613-836-3742
[email protected] | www.mcintoshperry.com
MEMORANDUM
To: Brett Gratrix, P.Eng. (City of Barrie)
From: Jacky Ho, P.Eng. (McIntosh Perry)
Date: February 28th, 2020
Re: Dunlop Street West from Sarjeant Drive to Anne Street North Utility Relocation Memo – Dunlop Street Widening
1.0 INTRODUCTION
McIntosh Perry Consulting Engineers Ltd. (MP) has been retained by the City of Barrie to complete a Schedule “C”
Municipal Class Environmental Assessment (MCEA) for Dunlop Street from Ferndale Drive North to Anne Street
North including intersection improvements. This project will be completed in conjunction with Ontario Ministry of
Transportation (MTO) Contract Number: CR 2017-E-0032 (Phase 2 – DD 3 Underpass Structures and Reconstruction
of Hwy 400 and Dunlop Street). MP is responsible to confirm findings of Phase 1 and 2 completed as part of the
MMATMP Update and undertake Phase 3 and 4 of the MCEA process in order to determine City’s transportation
needs on Dunlop Street West as well as complete the preliminary design of the preferred alternative identified
during the MCEA process.
The current design footprint of the Dunlop Street, and the ramp terminals has been based on the original
conceptual design found in the approved Transportation Environmental Study Report (TESR). MP has since further
refined the TESR design to for the Dunlop Street improvements, for Design Option A. This design alternative
includes road improvements between Sarjeant Drive and Anne Street. It follows closely with the TSER conceptual
design and the MTO approved right-of-way requirements. It is a design solution to improve the Dunlop Street
corridor and accommodate the MTO’s Dunlop Interchange project, while minimizing property impacts.
The purpose of this memo is meant to outline any potential conflicts with the proposed widening of Dunlop Street
and corresponding utilities that may need relocation and/or protection in the detail design.
2.0 UTILITIES AND POTENTIAL CONFLICTS
The Dunlop Street corridor has many utilities, both above and underground that will be reviewed in this memo to
document potential conflicts that will need to be resolved as the project progresses through the design stages. The
following section will outline the known utilities from circulation in the summer of 2019 and previous MTO Study
(PDR) as both projects are in conjunction with one another.
At the time of the circulation in summer of 2019, the following utilities notified us that there were no conflicts:
Cogeco, Enwave, Group Telecom, Telus, Toronto Hydro, Hydro One (no underground transmission facilities).
Utility Relocation Memo City of Barrie – Dunlop Street Widening
2
All correspondence and markups received from the utility circulation can be found in Appendix A. The utility plan
can be found in Appendix B and the City of Barrie’s municipal infrastructure needs plan can be found in Appendix C.
2.1 Dunlop Street – Sarjeant Drive to Cedar Pointe Drive
2.1.1 City of Barrie
• 675 mm diameter concrete storm sewer, cover depth 1.2m crossing Dunlop Street (N-S) at Sarjeant Dr.
• 200 mm diameter D.I. water main, cover depth of 1.4m (north side)
• 2 x 300 mm diameter storm lead, cover depth of 1.1m crossing Dunlop Road (NW-SE)
• 2 x 375 mm diameter concrete storm sewer, cover depth of 1.3m crossing Dunlop
• 525 mm diameter storm sewer, cover depth of 1.1m along roadway (E-W)
• 525 mm diameter storm sewer, cover depth of 1.25m along intersection (N-S)
• 300 mm diameter concrete storm sewer, along intersection (N-S)
• 675 mm diameter storm sewer, cover depth of 1.6m (south side)
• 600 mm diameter A.C. sanitary sewer, cover depth 4.4m (north side)
• 200mm diameter sanitary sewer crossing Dunlop Street (N-S) and stub (E-W)
With the listed underground utilities, it is anticipated that some relocations will be required. With the widening of Dunlop
Street, the storm sewer infrastructure may be relocated as determined by the stormwater drainage design team. The
cover depths of the existing utilities will need to be confirmed in the later stages of the project to determine whether
relocation or protection is required. It was noted from a previous MTO study (PDR) that the existing watermain line and
storm sewer conflict with the reconstruction of the interchange. For further information, the City of Barrie’s municipal
infrastructure needs assessment plan can be found in Appendix C.
2.1.2 Bell
• Pedestal at 420 Dunlop St. West (north side)
• Pole at 420 Dunlop St. W (north side)
• 2 x Pedestal at 1 Sarjeant Dr.
• Pedestal at 404 Dunlop St. West
• Handhole at 395 Dunlop St. West
• Pedestal at 402 Dunlop St. West
• Handhole at 402 Dunlop St. West
• Fiber Distribution Interface at 380 Dunlop St. West
• OPI 401-4 at 380 Dunlop St. West
• 4D Manhole 5
• Underground conduit and buried cable
The above listed state the existing infrastructure for Bell along this section as per Bell markups. Locations and severity
of impact/conflict will need to be addressed by Bell in the detail design. Relocation, adjustments and/or protection
is anticipated to be required as there are potential conflicts with the reconstruction. Depths of buried conduit will
have to be confirmed through test pits to determine whether conduits need to be lowered underground or relocated,
Utility Relocation Memo City of Barrie – Dunlop Street Widening
3
as not to impact the reconstruction of Dunlop Street West and boulevard design with the proposed road cross
section.
In addition to the markups provided by Bell, the utility plan as referenced from the MTO Study provided additional
utility lines. However as per the utility plan, “any utility lines with a (QL’D’) designation could not be filed located and
is positioned on the map as accurately as possible by records only”.
2.1.3 Rogers
• Joint use pole at 416 Dunlop St. West
• Hydro pole
• Spare buried coaxial cable
• Buried coaxial cable
• Aerial coaxial cable
• Buried fibre cable
• Aerial fibre cable
• Joint use pole at 391 Dunlop St. West
• Rogers Ground level box at 396 Dunlop St. West
• Rogers pedestal at 396 Dunlop St. West
• 2 x manhole at 396 Dunlop St. West
• Pedestal at 4 Cedar Pointe Drive
The above existing Rogers utilities are portrayed on Roger’s markup of the study area. Relocation will be anticipated,
as Roger’s states that the standard depth of their existing plant is 1 m. Rogers may have to lower their plant in order
to achieve a 1 m vertical clearance from proposed roadway cross section. As identified in the PDR, the Rogers buried
coaxial and fibre cable conflict with the reconstruction of the interchange and relocation is required. It is also noted
that Rogers plant is currently under construction.
2.1.4 Alectra
• 7 poles on Dunlop St. West
• 2 poles on Sarjeant Dr.
• 3 U/G Transformer along Dunlop St. West
• 1 U/G transformer on Sarjeant Dr.
• U/G primary cable
• Trench location for Alectra utilities cable
Based on the markup received from Alectra, the poles are located along the property line of the City’s existing Right-
of-Way (ROW). The underground transformers and primary cables are not within the City’s ROW on Dunlop St.
except for along Sarjeant Drive. Relocation plans is anticipated to be required as some of Alectra’s infrastructure
conflicts with the proposed design.
Utility Relocation Memo City of Barrie – Dunlop Street Widening
4
2.1.5 Enbridge
Enbridge submitted drawings providing the general location of their gas plant and would require detailed drawings
to be submitted before approval. As per these drawings, a gas main is located on the north side of Dunlop St. W,
3.6m offset to the south from the existing City’s ROW. Another gas main is located on the south side of Dunlop St.
W with an offset of 3.7m to the north of the existing City ROW. These two gas mains connect, crossing Dunlop Street.
The MTO Study (PDR) utility plans show a gas main on the north side of Dunlop St. from the intersection of Cedar
Pointe Dr. A gas main is also shown on the south side of Dunlop Street. As part of the Utility meeting for the PDR,
Enbridge had noted that they have a 4-inch plastic gas main near the intersection of Cedar Pointe Drive and Dunlop
Street. It was also noted that potential relocation or protection is dependant on the finalized proposed layout and
design.
2.2 Dunlop Street – Cedar Pointe Drive to West of Hart Drive West Side
2.2.1 City of Barrie
• 600 mm diameter A.C. sanitary sewer, cover depth 4.0m – 4.5m (north side at Cedar Pointe Dr.)
• 200 mm diameter D.I. water main, cover depth of 1.4m (north side at Cedar Pointe Dr.)
• 450 mm diameter concrete storm sewer, insulated (north side on Cedar Pointe Dr.)
• 250mm diameter storm lead, cover depth 1.7m (southeast corner at Cedar Pointe Dr.)
• 250mm diameter storm lead, cover depth 1.5m (southeast corner at Cedar Pointe Dr.)
• 300mm diameter storm (southeast corner on Cedar Pointe)
• 760mm diameter A.C. industrial trunk sanitary sewer (N-S on structure)
• 1400mm diameter tunnel liner, cover depth 8.0m (N-S on structure)
• 150mm diameter watermain, cover depth 1.6m (west of Hart Dr.)
• 1200mm x 1800mm culvert, cover depth 4.0m (NW at the intersection of Hart Dr.)
• 300mm diameter storm sewer, cover depth 1.6m (NW across intersection of Hart Dr.)
City of Barrie utilities conflicts with the reconstruction of Dunlop Street West. As mentioned in the MTO PDR, existing
sanitary sewer conflicts with the replacement of the bridge, and relocation will be required. The water main and storm
sewer near Hart Drive conflicts with the reconstruction of the interchange. It was also noted that field verification of the
watermain could not be located on the east side of the intersection of Cedar Pointe Drive. For further information, the
City of Barrie’s municipal infrastructure needs assessment plan can be found in Appendix C.
2.2.2 Bell
• Pedestal at 356 Dunlop St. West
• Pedestal OPP at 354 Dunlop St. West
• 4D manhole 4 at 354 Dunlop St. West
• 4D manhole 3, manhole 2, manhole 1-1
• Pedestal at 304 Dunlop St. West
• Pedestal at 297 Dunlop St. West
• Pedestal at 5 Hart Dr.
Utility Relocation Memo City of Barrie – Dunlop Street Widening
5
• Underground conduit and buried cable
Relocation will be needed along this section as the Bell infrastructure conflicts with the proposed replacement of the
bridge as well as the reconstruction of the road and interchanges. Coordination with Bell will be required once the
geometry and general layout is finalized for Bell to proceed with relocation drawings. It is also noted on MTO PDR
that Rogers plant is running in Bell duct along Dunlop Street West.
2.2.3 Rogers
• Existing spare buried coaxial cable along Dunlop St. West
• Pedestal on Dunlop St. West
• 2 x manhole on Dunlop St. West
Relocation of the above noted infrastructure is anticipated due to the widening of the Dunlop Street West.
Confirming with the PDR, relocation is required. As stated previously, Roger’s plant is under construction and thus
coordination with Rogers will be required for relocation updates.
2.2.4 Alectra
• 3 poles on Dunlop St. West
• 1 U/G Transformer on Dunlop St. West
• U/G primary cable
• Trench location for Alectra utilities cable
Alectra poles are within the City’s ROW along this section, as well as underground cable crossing Dunlop Street
West. A relocation plan will need to be provided for the poles and possibly some of the underground
transformers.
2.2.5 Enbridge
The gas main discussed in section 2.1.5 crosses the Cedar Pointe Drive intersection from the north of Dunlop
Street West along Cedar Pointe Drive. In addition, as mentioned in the PDR, the existing Enbridge utility also
conflicts with the replacement of the culvert and reconstruction interchange at Cedar Pointe Drive.
Just west of the Hart Drive and Dunlop intersection, the PDR utility plan shows a gas main crossing Dunlop
Street West. Enbridge will need to review and confirm whether utility relocation or protection is required along
this section. The drawings obtained from Enbridge shows a gas main offset of 0.9m from the property line at
304 Dunlop Street West, but does not cross south to 297 Dunlop Street West as it shows on the PDR utility
plans.
2.3 Dunlop Street – East of Hart Drive to West of Anne Street
2.3.1 City of Barrie
• 150mm diameter water main, cover depth 1.6m (E-W)
• 200mm diameter D.I. water main, cover depth 2.3m (N-S at Hart Dr.)
• 1200mm x 1800mm culvert, cover depth 4.0m (NW at the intersection of Hart Dr.)
• 1800mm diameter concrete storm sewer, cover depth 3.2.m (N-S at Hart Drive)
Utility Relocation Memo City of Barrie – Dunlop Street Widening
6
• 300mm diameter storm sewer, cover depth 1.6m (NW across intersection of Hart Dr.)
• 225mm diameter storm sewer, cover depth 1.0m (E-W)
Relocation and protection will be required as the storm sewer and water main conflicts with the reconstruction of the
interchange as mentioned in the MTO PDR. It was also noted that the 200mm watermain was unable to be field verified.
For further information, the City of Barrie’s municipal infrastructure needs assessment plan can be found in Appendix C.
2.3.2 Bell
• Pedestal at 285 Dunlop St. West
• Pedestal R at 281 Dunlop St. West
• Pedestal at 281 Dunlop St. West
• Pole at SW corner of Anne St. and Dunlop St. West
• 4D manhole 1 at NW corner of Anne Street and Dunlop St. West
• Underground conduit and buried cable
As similarly discussed in section 2.1.2 and 2.2.2, utility relocation, adjustments and protection will be required
due to the road reconstruction widening along this section. Location of infrastructure will need to be confirmed
by Bell during circulation.
2.3.3 Rogers
• Hydro pole at 12 Hart Drive
• Buried coaxial cable
• Aerial coaxial cable
• Spare buried coaxial cable
• Hydro pole at 290 Dunlop St. West
• Hydro pole at 285 Dunlop St. West
• Pedestal at 292 Dunlop St. West
• Rogers building attachment at 284 Dunlop St. West
• 3 x manhole at 280 Dunlop St. West
It is noted that PDR utility plan that Rogers record indicate plant is running in Bell duct along Dunlop. Coordination will be
required between Bell and Rogers to determine relocation and planning of the underground plant.
2.3.4 Alectra
• 3 poles on Dunlop St. West
• 2 poles on Hart Dr.
• 2 U/G Transformer on Dunlop St. West
• 1 U/G Transformer on Hart Dr.
• U/G primary cable
• Trench location for Alectra utilities cable
Utility Relocation Memo City of Barrie – Dunlop Street Widening
7
As stated previously, a relocation plan will be required as Alectra poles are within the City’s existing ROW and
conflicts with the proposed design. Although the underground transformers are not within the City’s existing ROW,
potential relocation may be required as per Alectra’s plans.
2.3.5 Enbridge
The gas main discussed in section 2.2.5 at 304 Dunlop Street West continues along the northside of Dunlop
Street to the east to Anne Street. A gas main along Hart Drive, with an offset of 3m to the west from 285 Dunlop
Street West continues north connecting to the previously discussed gas main, crossing Dunlop. As stated
previously, Enbridge will have to review and comment on whether protection and/or relocation is required.
3.0 NEXT STEPS
Proceeding through preliminary and detail design, the circulation of the design plans should follow for all the stated
utilities in this memo. Coordination with all affected parties will be required to discuss the potential conflicts and
relocation and daylighting plans in order to mitigate risk of unexpected utility conflicts in detail design.
Utility Relocation Memo City of Barrie – Dunlop Street Widening
APPENDIX A – Utility Circulation Correspondence
Bell Canada Municipal Operations Centre - C/O TELECON DESIGN INC.
7777 Weston Rd,
Vaughan, Ontario L4L 0G9
Ph: (905) 569-2882
APPLICATION FOR PLANT LOCATION AND CONSENT
Applicant: Mcintosh Perry
Mark Up #: 78262
Applicant Ref #: N/A
Location: Dunlop St W from Ferndale Rd N to Anne St
Switching Center/NNX: Barrie/722
Date Received from Applicant: 2019-07-10
Marked By: THUY DANG
APPLICATION FOR PLANT LOCATION AND REQUEST
Existing and/or proposed Bell Canada underground plant are indicated on the attached plan
Our records show no existing and / or proposed underground plant within 2m of your proposed installation
Conflict indicated
Meets with our approval
Not for PUCC approval - Mark up only
If within 1 meter of Bell plant, hand dig
REMARKS: Call for locates 1.800.400.2255. Tie-in measurements are a guideline only and physical
verification may be required by applicant to determine the true separation between plants. Maintain clearance of 0.6m. Hand dig when crossing Bell plant.
PROCEDURES TO FOLLOW:
1. Request locates prior to construction 1-800-400-2255 2. If exact location and depth are critical - test pits are recommended 3. Bell Canada plant location information is approximate 4. If the location of your proposed design changes, it will be necessary to re-apply 5. Permits expire six (6) months from approval date
Signature: THUY DANG
______________________________
Date: September 20,2019
________________
OVERHEAD PLANT NOTSHOWN ON DRAWING.
THE ACCOMPANYING DATA IS SU PPLIEDAS A MATTER OF COU RTESY AND IS INNO WAY TO BE TAKEN, ASSOCIATEDWITH OR IN PLACEMENT OF COPIES OFTHE OFFICIALLY SIGNED AND SEALEDDOCU MENTS. THE DATA IS PROVIDED“AS IS” WITHOU T A WARRANTY OF ANYKIND EITHER EXPRESSED OR IMPLIED.ANY PERSON(S) MAKING U SE OF ORRELYING U PON THIS DATA IS/ARERESPONSIBLE FOR CONFIRMING ITSACCU RACY AND COMPLETENESS.THESE FILES DO NOT INCLU DE A
PROFESSIONAL ENGINEER’S STAMPONTHE DRAWINGS, AND ONLY DRAWINGSWITH SU CH STAMPS ARE TO BE
CONSIDERED AS TRU E AND FINAL ASISSU ED BY OU R OFFICE.
PRIOR TO ANY EXCAVATION:CALL BEFORE YOU DIG
CONTACT ONTARIO ONE CALL @1 800 400-2255 OR www.on1call.com
LakeSim coe
BAYFIELD ST
MILLER DR
FAIRVIEWRDCOLLIER ST
ANNE ST N
TOWN LINE RD BU RTONAVE
COU NTYROAD90
ANNESTS
ESSA RD
EDGEHILLDRFERNDALE DR NTIFFIN ST
BRADFORD ST
LAKESHOREDR
DU NLOP ST W
HWY400
TOWNLINE
COU NTYROAD 40
ROSS ST
GROVEST E
SU NNIDALE RD
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
wÍ
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Íw
Í
w
Í
w
Í
wÍ
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
!
!
!!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
! !
!
!
!
!
!
!
!
!
!!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
! !
!
! !
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
! !
!
C A U T I O N : D E L T A S E R V I C EC A U T I O N : D E L T A S E R V I C E
S P R O U L E D R
S P R O U L E D R
E L L I O T T A V E
E L L I O T T A V E
SAR
J E AN
T DR
S AR
J E AN
T DR
L E N N O X D RL E N N O X D R
F E R N D A L E I N D U S T R I A L D R
F E R N D A L E I N D U S T R I A L D R
HHAA
RRTT
DDRR
F E RN
DA
L E DR
N
F E RN
DA
L E DR
N
HHWW
YY44
0000
D U N L O P S T W
D U N L O P S T W
CCEE DD
AARR
PPOO
II NNTT
EEDD
RR
³
KEY PLANLegend
! Pole Owned By Others
! Alectra Owned Poles
U /G Prim ary Cable
Aband oned U /G Prim ary Cable
\\\\ Trench Location for Road Crossing
Trench Location for Alectra U tilities Cable
Í
w
U /G Transform er
) Hand hole
Õ̀ Cable Cham ber
Transm ission Lines
Rail Road
Stream s
Water
Dunlop Street West \ 2019-DP-2553
Barrie
19 Jul 20191:2,000
CREATED AND OPTIMIZED FOR 36" x 24"
0 50 10025Meters
ON1 TICKET NU MBER:
SCALE: DATE CREATED:
CITY:
PAPER SIZE:
µÍ
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w
Í
w Í
w
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!!
!
!
!
!
!
!
!
!
!
!
!
!
!
!!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!!
!
!
!
!
!
!
!
!
!!
!
!
!
!
!
!
!
!
!
!
!
!
!
!!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!
!!
!
!
!
!
!
!
! !
!
!
!!
!
!
!
!
!
!
!
!!
C A U T I O N : D E L T A S E R V I C EC A U T I O N : D E L T A S E R V I C E
M U L H O L L A N D S TM U L H O L L A N D S T
R O B E R TR O B E R TS TS T
W E L L I N G T O N S T WW E L L I N G T O N S T W
V I C T O R I A S TV I C T O R I A S T SA
NF O
RD
SA
NF O
RD
ST
ST
E CC L E S
S T N
E CC L E S
S T N
F RA
NC E S S T S
F RA
NC E S S T S
EECCCC
LLEESSS S
T TS S
F RA
NC E S S T N
F RA
NC E S S T N
D O N A L D S TD O N A L D S T
G E O R G E S TG E O R G E S T
AANN
NNEE
SSTTSS
P E R R Y S TP E R R Y S T
AN
NE S T N
AN
NE S T N
V E S P R A S TV E S P R A S T
H WY 4
0 0
H WY 4
0 0
H E N R Y S TH E N R Y S T
D U N L O P S T W
D U N L O P S T W
IINNNN
IISSFFIILL
SSTT
BO
YS
S TB
OY
S S T
CCEE
DDAA
RRPP
OOII NN
TT EEDD
RR
H A R T D RH A R T D R
EGD File Number: 23027784 Re: Dunlop EA - Utility Markup Circulation - Enbridge
o By law utility locates must be obtained prior to starting any excavation or ground disturbance activity, such as pile driving, boring, auguring or digging.
o Contact Ontario One Call at 1-800-400-2255 or www.on1call.com at least 5 business days before beginning work to obtain utility locates. o Please refer to the “Third Party Requirements In the Vicinity of Natural Gas Facilities” for requirements and precautions for working safely
in the vicinity of natural gas pipelines. The most recent version of this document is available at: https://www.enbridgegas.com/~/media/Extranet-Pages/Safety/Before-you-dig/Third-Party-Requirements-in-the-Vicinity-of-Natural-Gas-Facilities
o Enbridge’s responses are based on the information available and are valid for a period of 6 months from issue.
VITAL MAIN
You are working within 3m of a Vital Main Pipeline. In order to accommodate Enbridge vital main standby requirements, our Damage
Prevention department must be contacted a minimum of three business days prior to commencing any excavation at 1-866-922-3622 to
schedule a site meeting.
NEB PERMIT REQUIRED
When crossing or working within 30m of the right-off-way of an NEB regulated natural gas pipeline, a permit must be obtained from the pipeline
company (attached).
Completed permit applications may be submitted to the Enbridge Gas Distribution Inc. NEB Engineer at [email protected]
Completed permit applications may be submitted to the Enbridge Gas Distribution Inc. NEB Engineer at [email protected]
CONFLICT
We have an OBJECTION to your proposed plant as indicated. Please refer to the attached drawings for information on our existing or proposed gas
plant.
You must submit a revised design for our approval that meets the requirements detailed in the Third Party Requirement book before proceeding.
If relocation of our plant is required, please contact:
Toronto Region Jaclyn Mui 416-495-7222 [email protected]
Central Region West Meetpal Chhina 905-458-2159 [email protected]
Central Region East Ashu Kahol 905-927-3017 [email protected]
Niagara Region Rhonda Nicholson 905-641-4815 [email protected]
Eastern Region Ottawa Sonia Padamadan 613-748-6861 [email protected]
Easement Crossing Anissa Trenholm 416-753-6937 [email protected]
NO-CONFLICT
We have NO OBJECTION to your proposed plant as indicated. Please refer to the attached drawings for information on our existing and/or proposed
gas plant. GAS MAINS MUST BE FIELD LOCATED. Before digging, please call ONTARIO ONE CALL at 1-800-400-2255 for free gas locates.
GENERAL LOCATION
Refer to the attached drawings for information on our existing and/or proposed gas plant within the road allowance.
The information provided is for GENERAL LOCATION ONLY and is not an approval. Detailed plans must be submitted for our review before an
approval will be granted.
Kind Regards,
Enbridge Gas Distribution Inc. [email protected] 500 Consumers Rd. North York, ON, M2J 1P8 Canada www.enbridge.com/gas
Plotted By: 7/12/2019 4:38:12 AMMoheswarRao Simadri
HIGHW
AY 90
SPROULE DRIVE
DUNL
OP ST
REET
FERNDALE INDUSTRIAL DRIVE
1.0m
3.6m
3.7m
0.6m0.6m
3.7m
3.7m
0.9m
3.6m
3.7m
4.2m E/HP
8.2 m W/EBL
1.9 m E/HP
4.5 m W/HP
3.5 m E/HP
NPS 6
SC IP
5-61-1
35 to
138
5-59-38 to 40
NPS 2 PE IP
5-41-102
NPS 4 SC IP
5-41-102
NPS 4 SC IP
NPS 2 PE IP
5N515-6
5N515-6
NPS 1 1/4 PE IP
5-65-142 to 144
NPS 4 SC IP
5-36-38
NPS 2 SC IP
5-39-126
NPS 2 SC IP
NPS 2 PE IP5-42-56
NPS 4 SC IP
5-36-36
5-56-66 to 67
NPS 4 SC IP
5-65-142 to 144
NPS 4 SC IP
NPS 4 PE IP
5N515-6
NPS 2 PE IP
5-192-55
5N823-4
NPS 2 PE IP
5N823-5
NPS 2 PE IP
NPS 4 PE IP
5N0823-4
NPS 4 PE IP
5N0823-5
010664
020667
022535
3664434
T
T
T
T
T
NPS 1 1/4 PE IP
5-133-92
5-70-98
NPS 1/2 PE IP
5-192-113
NPS 1 PE IP
5-193-10
NPS 1 PE IP
5-193-12
NPS 1 PE IP
5-84-70
5-193-6
NPS 1 1/4 PE IP
5-53-27
5-171-84
5-193-16
K
K
K
K
K
K
!(3751!(4198
!(4197
!(4190
!(1206
!(609!(1416
!(1282
!(608
!(1207
!(1283
!(4977
!(4979
!(4980
!(4978
!(5271
!(5277
!(5279
!(5487
!2(
!2(
!2(
DUNLOP ST
FERNDALE DR
SPROULE DR
FERNDALE INDUSTRIAL DR
ELLIOTT AVE
LENNOX DR
CENTER ST
¯ Date Plotted:
Note : Map is not to scale.
Plotted By: 7/12/2019 4:41:52 AMMoheswarRao Simadri
LENNOX DRIVE
DUNLOP STREET
FERNDALE DRIVE
SARJEANT DRIVE
ELLIOTT AVENUE
3.6m
3.7m
3.7m
3.6m
3.7m
3.7m
3.7m
2.4m
3.7m
3.7m
3.6m
3.7m
3.7m
0.9m
3.5m
3.7m
3.7m
3.7m
3.6m
3.7m
0.7m N/HP
1.8m
1.5m W/WBL
1.5m
W/W
BL
4.2m E/HP
8.2 m W/EBL
1.9 m E/HP
5-41-102
NPS 4 SC IP
5-41-102
NPS 4 SC IP
5-41-102
NPS 4 SC IP
5-134-104
NPS 2 SC IP
5-48-63
NPS 2 PE IP
NPS 4 SC IP
5-64-26
5-39-126
NPS 2 SC IP
NPS 2 PE IP
5-66-11 to 12
5-65-142 to 144
NPS 4 SC IP
5-36-38
NPS 2 SC IP
5-39-126
NPS 2 SC IP
NPS 4 SC IP
5-36-36
5N0654-1
NPS 2 PE IP
NPS 2 PE IP
5N0654-1
NPS 2 SC IP
5-39-126
NPS 2 PE IP
5-66-11 to 12
5-65-142 to 144
NPS 4 SC IP
NPS 1 1/4 PE IP
5-86-67
5-65-1
46NP
S 4 SC
IP
NPS 1 1/4 PE IP
5-66-113
NPS 4 SC IP
5-64-26
5-66-1
14NP
S 1 1/
4 PE I
P
NPS 4 PE IP
5N0823-4
NPS 4 PE IP
5N0823-5
NPS 2 PE IP
5-64-30
022536
010664
020667
022535
8520273
T
T
T
T
T
NPS 1 1/4 PE IP
5-133-92
5-70-98
NPS 1 1/4 PE IP
5-151-53
NPS 1 PE IP
5-181-145
NPS 1/2 PE IP
5-192-113
NPS 1 PE IP
5-193-12
NPS 1 PE IP
5-84-70
5-193-6
NPS 1 1/4 PE IP
5-53-27
5-171-84
5-193-16
NPS 2 PE IP
5-125-61
K
K
K
K
K
K
K
K
K
K
K
U
!(3751
!(4534
!(4532
!(1400
!(1399
!(1206
!(609!(1416
!(1044
!(1282
!(735
!(1398
!(608
!(1045
!(1422
!(4979
!(4980
!(4978
!(5271
!(5778
!(5782
3WT
3WT
NBT
!2 (! 2(
!2(
!2(
!2(
!2(
DUNLOP ST
FERNDALE DR
LENNOX DR
SARJEANT DR
ELLIOTT AVE
UNKNOWN
CEDA
R PO
INTE
DR
FERNDALE INDUSTRIAL DR
UNKNOWN
¯ Date Plotted:
Note : Map is not to scale.
Plotted By: 7/12/2019 4:43:23 AMMoheswarRao Simadri
HART DRIVE
HART
DRI
VE
HIGHWAY 400
DUNLOP STREETVESPRA STREET
CEDA
R PO
INT D
R
1.8m
3.6m
3.7m
3.7m
0.6m
3.0m
3.6m
3.7m
0.4m
0.6m
3.7m
4.0m E/EBL
2.4m N/NBL
2.4m E/EBL
1.8m S/SBL
16.5m S/SBL
0.7m N/HP
1.8m
2.4m S/SBL
2.4m S/SBL
3.0m W/W
BL
1.5m W/WBL
1.5m
W/W
BL
1.5m N/NBL
3.2m W/WBL
4.2m
N/NB
L
3.0m
N/NB
L
4.5m S/SBL
5-134-104
NPS 2 SC IP
5-48-63
NPS 2 PE IP
5-81-38NPS 2 PE IP
5-81-36
NPS 2 PE IP
NPS 2 PE IP
5N266-3
NPS 2
PE IP
5-63-6
5 to 66
NPS 4 SC IP
5-65-146
NPS 4 SC IP
5-64-26
5-39-126
NPS 2 SC IP
5-65-142 to 144
NPS 4 SC IP
5-39-126
NPS 2 SC IP
5N623-1NPS 2 PE IP
5N623-1NPS 2 PE IP
NPS 2 SC IP
5-39-126
5-68-52NPS 1 1/4 PE IP
5-65-1
46NP
S 4 SC
IP
NPS 1 1/4 PE IP
5-86-67
NPS 1 1/4 PE IP
5-86-66
5-86-65
NPS 1 1/4 PE IP
NPS 1 1/4 PE IP
5-86-63
NPS 1 1/4 PE IP
5-86-64
NPS 1 1/4 PE IP5-104-84
NPS 1 1/4 PE IP5-104-83
5-65-1
46NP
S 4 SC
IP
5-66-115NPS 1 1/4 PE IP
NPS 1 1/4 PE IP
5-66-113
NPS 4 SC IP
5-64-26
NPS 1 1/4 PE IP
5-86-61
5-86-6
1NP
S 1 1/
4 PE I
P
NPS 1 1/4 PE IP5-86-61
5-66-1
14NP
S 1 1/
4 PE I
P
5-73-139
NPS 1 1/4 PE IP
NPS 2 PE IP
5-64-30
022536
8520273
T
T
NPS 1 1/4 PE IP
5-67-132 to 135
NPS 1 1/4 PE IP
5-68-4
NPS 2 PE IP
5-125-61
K
K
K
K
K
K
K
K
K
K
K
U
!(4534
!(4532
!(1400
!(1399
!(1044
!(735
!(1398
!(1343
!(1422
!(1379
!(1719
!(1721
!(2976
!(4938
!(5777
!(5778
!(5780
!(5781
!(5783
!(5782
!(5784
!(5785
!(5787
!(5789
!(5791
!(5788
3WT
3WT
NBT
NBT
NBT
!2 (! 2(
!2(
!2(
!2(
!2(
400
DUNLOP ST
HART DR
UNKNOWN
CEDA
R PO
INTE
DR
VESPRA ST
SARJEANT DR
UNKNOWN
UNKN
OWN
400
UNKNOWN
¯ Date Plotted:
Note : Map is not to scale.
Plotted By: 7/12/2019 4:45:28 AMMoheswarRao Simadri
HART DRIVE
ANNE STREET
ANNE STREET
HIGHWAY 400
HENRY STREET
DUNLOP STREET
GEORGE STREET
DUNLOP STREET
CEDA
R PO
INT D
RIVE
1.8m
1.8m
4.5m
4.5m
3.7m2.7m
2.7m
4.9m
5.2m
3.0m
1.8m
3.4m
0.9m N/NCL
3.0m
3.0m
1.8m
3.7m
4.9m2.2m
3.2m N/NBL
2.5m N/NBL
8.7m W/WBL
18.2m W/WBL
12.8m
W/W
BL
4.8m
W/WB
L
3.7m
W/WB
L3.7
m W/
WBL
4.0m E/EBL
2.4m N/NBL
1.8m S/SBL
16.5m S/SBL
3.2m W/WBL
4.2m
N/NB
L
3.0m
N/NB
L
1m S
/HP
1.2m S/FH
8.1m N/NBL
5-61-73 to 75
NPS 2 PE IP
5-68-1
27NP
S 4 SC
IP
5-11-32
NPS 6 SC IP
NPS 2 SC IP
5-13-50
NPS 2 SC IP
5-13-50
5-64-144
NPS 2 PE IP
5-11-30
NPS 6 SC IP
NPS 6 SC IP
5-11-30
5-12-121
NPS 12 SC IP
5-12-136
5-18-150
5-60-31
NPS 2 SC IP
5-11-36
NPS 12 SC IP
5-18-150
NPS 2 SC IP
NPS 2 PE IP
5-50-144
5-186-124
5-61-73 to 75
NPS 2 PE IP
NPS 2
PE IP
5-63-6
5 to 66
5-13-82
NPS 2 SC IP
5N44-1NPS 1 1/4 PE IP
5-68-1
27NP
S 4 SC
IP
NPS 4 SC IP
5-65-146
5-70-142
NPS 1 1/4 PE IP
5-68-52NPS 1 1/4 PE IP
5-68-5
3NP
S 1 1/
4 PE I
P
5-65-1
46NP
S 4 SC
IP
NPS 1
1/4 P
E IP
5-70-1
41
5-69-9
65-6
9-97
NPS 1
1/4 P
E IP
NPS 1 1/4 PE IP
5-86-67
NPS 1 1/4 PE IP
5-86-66
5-86-65
NPS 1 1/4 PE IP
NPS 1 1/4 PE IP
5-86-63
NPS 1 1/4 PE IP
5-86-64
NPS 1 1/4 PE IP
5-86-61
5-86-6
1NP
S 1 1/
4 PE I
P
NPS 1 1/4 PE IP5-86-61
NPS 2 PE IP
5-73-126
NPS 1 1/4 PE IP
5-75-75
5-75-74
NPS 1 1/4 PE IP
5-75-74
NPS 1 1/4 PE IP
010774
010775
010776
010777
010782
010783
T
T
T
T
T
T
NPS 1 1/4 PE IP
5-69-113
5-103-140
NPS 1 1/4 PE IP
5-69-135
NPS 1 1/4 PE IP
5-65-97
NPS 1 1/4 PE IP
5-93-95 to 107
5-101-118
NPS 1 1/4 PE IP
5-68-4
NPS 1 PE IP
5-192-121
K
K
K
K
K
K
K
K
K
K
K
K
K
!(1674
!(36
!(1106
!(43
!(2115
!(35
!(1342
!(45
!(46
!(1418
!(34
!(1343
!(5773
!(5774
!(5777
!(5779
!(5780
!(5785
!(5787
!(5789
!(5791
!(5792
!(5796
NBT
NBT
NBT
NBT
!2(
!2(!2(
!2(
!2(
5-192-12740
0
DUNLOP ST
UNKNOWN
ANNE ST
HART DR
GEORGE ST
HENRY STCE
DAR
POIN
TE D
R
PERRY ST
VESPRA ST
UNKN
OWN
UNKN
OWN
400
UNKNOWN
¯ Date Plotted:
Note : Map is not to scale.
Plotted By: 7/12/2019 4:47:13 AMMoheswarRao Simadri
ANNE ST
THOMAS ST
BOYS STREET
ANNE STREET
BOYS STREET
ANNE STREET
PERRY STREET
PERRY STREET
HENRY STREET
HENRY STREET
HENRY STREET
DUNLOP STREET
DUNLOP STREET
DUNLOP STREET
FRANCES STREET
3.7m
3.7m
2.7m
4.9m
5.2m
1.2m
5.2m
1.8m
3.6m
4.0m
1.2m
1.2m
3.0m
1.2m
3.4m
1.2m
1.2m
1.2m
1.8m
3.4m
0.9m N/NCL
3.0m
1.8m
3.7m
0.9m 1.2m3.9m
1.2m W/EPOLES
5.1m
4.9m
2.2m
5.1m
5-61-73 to 75
NPS 2 PE IP
NPS 2 PE IP
5-73-109
5-32-60
NPS 2 SC IP
5-11-30
NPS 6 SC IP
NPS 6 SC IP
5-11-30
5-12-121
NPS 12 SC IP
NPS 2 SC IP
5-10-81
NPS 12 SC IP
5-12-121 5-13-39
NPS 2 SC IP
5-15-22
NPS 2 SC IP
5-13-34
NPS 2 SC IP
5-13-88
NPS 2 SC IP
NPS 2 SC IP
5-13-86
5-11-109
5-45-76
NPS 2 SC IP
5-11-35
NPS 12 SC IP
5-12-84
NPS 2 SC IP
5-12-84
NPS 2 SC IP
NPS 2 SC IP
5-11-107
5-12-136
5-18-150
5-60-31
NPS 2 SC IP
5-11-36
NPS 12 SC IP
5-18-150
NPS 2 SC IP
NPS 2 PE IP
5-50-144
5-186-124
5-13-82
NPS 2 SC IP
5N44-1NPS 1 1/4 PE IP
5-11-15
NPS 12 SC IP
5-50-28
NPS 2 PE IP
5-12-124
NPS 12 SC IP
5-15-19
NPS 2 SC IP
T
010775
010776
010777
010778
Closed
010779
010780
010781
010782
010783
010784
010778
Closed
8575393
T
T
T
T
T
TT
T
T
T
T
NPS 1 1/4 PE IP
5-69-113
5-103-140
NPS 1 1/4 PE IP
5-93-95 to 107
5-101-118
NPS 1 PE IP
5-192-121
K
K
K
K
U
U
U
!(27
!(36
!(1106
!(43
!(40!(33
!(519
!(35
!(1342
!(37
!(38
!(42
!(41
!(44 !(50
!(32
!(920
!(847
!(34
!(39
8N
8N
8N
WSS
WSS
!2(
!2(
!2(
!2 (
!2(!2(
5-192-127 DUNLOP ST
ANNE ST
HENRY ST
BOYS ST400
PERRY ST
DONALD ST
FRANCES ST
THOMAS ST
HART DR
VESPRA ST
UNKNOWN
WELLINGTON ST
400
PERRY ST
BOYS ST
UNKNOWN
¯ Date Plotted:
Note : Map is not to scale.
Rogers Communications Outside Plant Engineering
244 Newkirk Rd
Richmond Hill, ON, L4C 3S5
August 2, 2019 Applicant:
August 16, 2019
S191271 Applicant Job No.: N/A
No Conflict
X No Conflict
For your Reference
EXTREME
CAUTION
CONFLICT
X CAUTION Rogers Communications has aerial plant in this area, as it is indicated on the attached plans.
X CAUTION
Note Proposed Fiber Optic Cable in a joint use duct structure .
X Note Plant currently under construction.
X Note
X Note Locates are still required. Call for locates at 1-800-738-7893
X Note Hand dig / Vac truck when crossing, or within 1.0m of existing Rogers plant.
X Note Plant is to Approximation.
August 16, 2019
DATE
289-657-8017
Please inform Rogers Communications a minimum of 6 - 12 months in advance of the proposed construction
schedule in order to coordinate our plant relocation.
Rogers Communications currently has existing plant as marked on your drawing. Our standard depth in this
municipality is: 1m.
Please ensure you maintain clearances of 1.0m vertically and 1.0m horizontally.
Use vactruck and expose ducts, maintain minimum of 1.0m clearance.
Markup Response Form
CAD Tech
Rogers Communications has reviewed your drawing(s) as requested and returns one marked-up copy.
Our comments follow below with an "X" indicating Rogers' stance on your proposed plan.
McIntosh Perry
Mabin Mathew
Comments:
Fiber Optic Cable is present in the area of your proposed construction. Please obtain locates and maintain
minimum 1.0m/1.0m clearance.
Your proposed construction appears to encroach within existing Rogers Communications plant.
Please relocate your proposed construction to allow adequate clearance of 1.0m vertically and 1.0m horizontally.
Application Date
Date Returned:
Rogers Ref. No.:
Location:
Rogers Communications currently does not possess existing plant in the area indicated on your attached plans.
DUNLOP RD
Enwave Utility Clearance Letter Attention: TPUCC Members Date: July 12th, 2016
Bay Adelaide Center, 333 Bay Street, Suite 710, Toronto, ON M5H 2R2 T: 416-338-8944 F: 416-363-6052 [email protected] www.enwave.com
If project falls within our boundaries, please submit your TPUCC application with relevant
drawings to [email protected]. We do not need to receive applications for projects that are
outside of District 1.
District 1 – Toronto & East York
Enwave currently has infrastructure in District 1 and the boundaries are as followed:
Northern: Bloor Street Eastern: Jarvis Street Southern: Lake Ontario Western: Spadina Avenue
This letter is valid until August 14th, 2017
GROUP TELECOM C/O Telecon Design Inc
7777 Weston Road, Vaughan, Ontario L4L 0G9
Ph: (905) 569 2882 Fax: (905) 460-8956
APPLICATION FOR PLANT LOCATION AND CONSENT
Applicant: McIntosh Perry
Mark Up #: GT19-2912
Applicant Ref #: Utility Record Request
Location: Dunlop Street
Date Received from Applicant: 07-10-2019
Marked By: Mary Tina
APPLICATION FOR PLANT LOCATION AND REQUEST
Existing and/or proposed Group Telecom underground plant are indicated on the attached plan
Our records show no existing and / or proposed underground plant within 2m of your proposed installation
Conflict indicated
Meets with our approval
Not for PUCC approval - Mark up only
If within 1 meter of GT plant, hand dig
REMARKS: Call for locates 1.800.400.2255. Maintain clearance of 0.6m. Hand dig when crossing Group Telecom plant. Call 877.865.6193 for locate if plant is in railway property.
PROCEDURES TO FOLLOW:
1. Request locates prior to construction 1-800-400-2255 2. If exact location and depth are critical - test pits are recommended 3. Group Telecom plant location information is approximate 4. If the location of your proposed design changes, it will be necessary to re-apply 5. Permits expire six (6) months from approval date
Signature: Mary Tina ______
Date: Jul 18, 2019 ____
Utility Relocation Memo City of Barrie – Dunlop Street Widening
APPENDIX B – Utility Plan
UT
UT
UT
UT
UT
UT
UTUT
Utility Relocation Memo City of Barrie – Dunlop Street Widening
APPENDIX C – Municipal Infrastructure Needs
Dunlop EA – Linear City Infrastructure Needs Assessment on Dunlop Street West (Preferred Alternative)
Section Asset Existing Need Rationale Plan Proposed Design/Cost Responsibility3
Proposed Construction/ Cost Responsibility3
Sarjeant Drive to WRT
Water 200mm DI, 1975 Replace with 300mm PVC (including new valves, services to property line, hydrants) Current fire flow requirements
Replace watermain with MTO’s Dunlop Project
COB to retain MP to design and MTO to construct at the COB cost.
MTO to construct at the COB cost.
Sanitary 600mm AC, 1972 Adjust MH frames/ grates as required for new road elevations Standard practice
MTO to identify as part of detailed design and construct.
MTO MTO
Storm – Dyments Creek Culverts (through Tim Horton’s/Wendy’s)
2-1800mm CSP, no install date
Project 52 in Drainage Master Plan, not suitable for incorporation into the MTO Dunlop Project due to scope of work. Defer until needed based on condition (noted in good condition on the City’s GIS web portal) or future widening to 7 lanes.
NA NA NA NA
Storm – Linear (Sarjeant Drive to Dyments Creek Daylighting)
675mm CONC, 1999
Assess need to upsize sewers to accommodate increased imperviousness, climate change Standard practice
MTO to assess sizing requirements as part of detailed design and construct recommended improvements.
MTO MTO
Storm – Linear (Keg entrance to WRT)
525mm CONC, 1999 Assess need to upsize sewers to accommodate increased imperviousness, climate change Standard practice
MTO to assess sizing requirements as part of detailed design and construct recommended improvements.
MTO MTO
Storm – Dyments Creek
Open Channel/Culverts at N-W/E & E/W-S ramps, Mainline 400, S-E ramp
MTO to modify channel as necessary to accommodate the road platform and replace culverts Per TESR/PDR MTO to undertake design and construction. MTO/City to discuss culvert termination at Hart Drive
MTO MTO
WRT to CL Hwy 4001
Water (CPD to 100m east)
200mm DI, 1999 Abandon section of watermain. 15 Cedar Pointe Drive fire coverage from Cedar Pointe Drive. NA Remove via excavation as location close to retaining wall footing (or fill with grout).
MTO2 MTO2
Sanitary (CPD to downstream junction)
600mm AC, 1972 Relocation required due to conflict with retaining wall and bridge abutment Conflict City to undertake detailed design City City
Sanitary (north of Dunlop Street, west side of Hwy 400 corridor)
750mm AC, 1971 Partial relocation required due to conflict with retaining wall and bridge abutment Conflict City to undertake detailed design City City
Sanitary (mainline 400 crossing)
750mm AC, 1971 Relocation required due to conflict with bridge abutment and widened platform for mainline 400
Confect City to undertake detailed design City City
Storm – Ditch/culvert south of 15 Cedar Pointe Drive
750mm CSP, 1999 and ditch
Assess need to upsize and lengthen culvert to accommodate road reconstruction. Upstream Drainage from Cedar Pointe Drive must be considered as the existing ditch south of Cedar Pointe Drive is anticipated to require removal to accommodate the retaining wall.
Conflict MTO’s consultant to complete assessment and construct recommended improvements.
MTO MTO
CL Hwy 400 to Hart Drive
Water (90m west of Hart Drive to Hart Drive)
150mm CI, 1963 Replace with 200mm PVC watermain (including new valves, services to property line, hydrants)
Current fire flow requirements, services are connected to this section of watermain
Replace watermain with MTO’s Dunlop Project
COB to retain MP to design and MTO to construct at the COB cost.
MTO to construct at the COB cost.
Sanitary NA NA NA NA NA NA
Storm - Linear Limited ex. infrastructure New local drainage in this section will need to be designed for the MTO road reconstruction project.
Standard Practice
MTO to undertake design and construction
MTO MTO
Storm – Bunkers Creek
1200x1800 CONC BOX, 1800x1800 CONC BOX near outlet
MTO to assess impacts and needs (hydraulic) associated with the interchange reconstruction and widening of Highway 400 both upstream and downstream of Dunlop Street and confirm the adequacy of the existing Bunkers Creek sewer as a suitable outlet per MTO drainage policies.
Standard Practice
MTO to undertake design and construction
MTO MTO
Hart Drive to Anne Street
Water 150mm DI, 1963 Replace with 300mm PVC (including new valves, services to property line, hydrants) Current fire flow requirements/ condition
Replace watermain with MTO’s Dunlop Project
COB to retain MP to design and MTO to construct at the COB cost.
MTO to construct at the COB cost.
Storm Linear (limited ex. Infrastructure)
New local drainage in this section will need to be designed for the MTO road reconstruction project.
Standard Practice
MTO to undertake design and construction
MTO MTO
Sanitary 250mm AC, 1974 Adjust MH frames/ grates as required for new road elevations Standard practice
MTO to identify as part of detailed design and construct.
MTO MTO
2 – minor cost item, if removal does not fall within scope for retaining wall construction, then consideration of City paying for abandonment
3 – subject to the MTO’s cost apportionment policy for utility relocations where the cost is not explicitly MTO’s responsibility as part of standard road reconstruction scope