Page 1: MEL 80 - BSCRS...patient management and best treatment results. Equipped to outperform Through the combined use of the pivoting patient supporting system between the VisuMax femtosecond

MEL 80High performance meets versatility

Page 2: MEL 80 - BSCRS...patient management and best treatment results. Equipped to outperform Through the combined use of the pivoting patient supporting system between the VisuMax femtosecond

2 3

Just what your clinic is looking for

Invest in the latest refractive excimer technology

The MEL 80™ is a top quality Carl Zeiss Meditec product, designed to make the

correction of vision defects even safer, more patient-friendly and individual. All

the parameters of this ultramodern work platform are oriented towards increasing

efficiency, achieving optimum treatment results and the rapid recovery of vision.

Key factors here are the very high ablation rate, the high-performance

eyetracker system, individual treatment planning with the optional CRS-Master®,

and the Eye Registration torsion compensation system.

MEL 80 – the excimer laser with the widest field of application

With immediate effect you now have the option of performing binocular treatment

planning with Laser Blended Vision for presbyopic patients. The corresponding

ablation profile aims to increase the depth of focus so that there is an overlapping

area after binocular treatment.

The best outlook for you and your patients

Added to this are tangible benefits for your daily work such as the overall

ergonomic design concept and the economical operation of the system. Reap the

advantages of an investment which is forward-looking, practical and profitable!

Aspherical profiles

Wavefront-guided treatment

Topography-guided treatment

Laser Blended Vision

Fast 1 kHz eyetracker

Eye registration

Data link to VisuMax® femtosecond laser// MEL 80 MadE By CarL ZEiss

Page 3: MEL 80 - BSCRS...patient management and best treatment results. Equipped to outperform Through the combined use of the pivoting patient supporting system between the VisuMax femtosecond

4 5

The faster the treatment,

the lower the stress

The MEL 80™ helps you significantly re-

duce the duration of treatment for your

patients. This has the following benefits:

•Thestromalbedisonlyopenfora

short period; this reduces dehydration

and shortens the regeneration process

•Thethermally-optimizeddistribution

of the laser firing pattern protects the

stroma – despite the high ablation

speed

•Patientstressisrelieved;theyonly

need to concentrate for a few seconds

on the fixation light

•Youcanincreaseyourefficiencylevels

and the number of patients you see

Everything’s under control!

An active eyetracker with excellent

feedback times and an ultrarapid IR

camera provides exact positioning

during the laser treatment. Thanks to

automatic pupil recognition you can

adjust the desired centering point

within seconds. This also includes the

limbus. If the center of the pupil shifts

with relation to the limbus during

ablation – through asymmetrical

contraction, for instance – the

eyetracker compensates for this.

By the way – no pupil-dilating medica-

tion and related waiting times are

necessary prior to this treatment.

Taylor-madeHighly user-friendly

Plume removal system

It couldn’t be simpler to operate

At Carl Zeiss, we strive to make ad-

vanced technology applications as

simple and ergonomic as possible for

our customers. When using the MEL 80

take advantage of an extensive list of

standardizedtreatmentproceduresfor

optimum results.

The software has been specially

developed for this workstation and its

graphic interface is clearly structured

and takes you step by step through

treatment. Click the mouse to enter

data or to import CRS-Master® files.

A large number of other helpful features

facilitate and support your work with

the MEL 80: the ergonomically designed

workstation, the individually positionable

monitor and the integrated video camera.

There are also practical options such as

a pivoting slit lamp.

The MEL 80 is also designed to accom-

modate future system developments

through various interfaces.

Page 4: MEL 80 - BSCRS...patient management and best treatment results. Equipped to outperform Through the combined use of the pivoting patient supporting system between the VisuMax femtosecond

6 7

CRS-Master

For a truly individual treatment

A top-notch treatment planning tool,

the CRS-Master integrates wavefront

examination and corneal topography

data for the MEL 80, thereby allowing

you to create truly individual treatment

programs. The inclusion of additional

patient-relevant data offers complete

individualizedopticalprofilesofyour

patients for tailored laser applications

VisuMax

Improved precision for incisions

The new VisuMax femtosecond system

allows you to operate with great accuracy

and, what’s more, less invasively. Thanks

to the system’s highly advanced laser

technology and innovative optical design,

corneal incisions with improved precision

are easily performed.

As such, the VisuMax offers a very

gentle treatment option for corneal

surgical procedures – for you and your

patients.

Perfectworkflow with a new swing

Efficient and individual at the same time! With the CRS-Master®, the MEL 80™ excimer laser and the VisuMax® femtosecond laser, Carl Zeiss has assembled three top-of-the-line products as a seamlessly coordinated systems solution for refractive laser surgery, including preoperative examinations,individualizedtreatmentplanningandpreciseflaps,followed by highly accurate refractive corrections and follow-up examinations–alldesignedtoensureconvenientworkflow,efficientpatient management and best treatment results.

Equipped to outperform

Through the combined use of the

pivoting patient supporting system

between the VisuMax femtosecond

system and the MEL 80 excimer laser,

patient transfers between surgical steps

are no longer necessary. The patient

experiences the surgery as an integrated

process. Unnecessary waiting periods

areminimizedandtreatmentefficiency

increased.

Systems that communicate

with each other

For efficient practice management

you benefit from optimally coordinated

product portfolio, diagnostics and

planning station, CRS-Master, MEL 80

excimer laser and VisuMax femto second

laser. We thus offer you an integrated

solution from a single source; a solution

that offers you the potential to sub-

sequently expand your networking

capabilities with continuously enhanced

dataflowefficiencyandindividualized

patient treatments.

CRS-Master®

VisuMax®

Page 5: MEL 80 - BSCRS...patient management and best treatment results. Equipped to outperform Through the combined use of the pivoting patient supporting system between the VisuMax femtosecond

Hyperopia Binocular Vision

20/25 & J5: 98.9%20/20 & J5: 97.7%

20/25 & J2: 92.0%20/20 & J2: 93.2%

45%

40%

35%

30%

25%

20%

15%

10%

5%

0%

J3J5

J7J12

J2

20/12,520/16

20/2020/25

20/32

Emmetropia

35%

30%

25%

20%

15%

10%

5%

0%

J3J5

J7J12

J2

20/12,520/16

20/2020/25

20/32

20/25 & J5: 99.1%20/20 & J5: 94.5%

20/25 & J2: 80.0%20/20 & J2: 77.3%

Hyperopia

45%

40%

35%

30%

25%

20%

15%

10%

5%

0%

J3J5

J7J12

J2

20/12,520/16

20/2020/25

20/32

20/25 & J5: 99.3%20/20 & J5: 98.5%

20/25 & J2: 94.9%20/20 & J2: 94.9%

Myopia

20/25 & J5: 98.9%20/20 & J5: 97.7%

20/25 & J2: 92.0%20/20 & J2: 93.2%

45%

40%

35%

30%

25%

20%

15%

10%

5%

0%

J3J5

J7J12

J2

20/12,520/16

20/2020/25

20/32

Emmetropia

35%

30%

25%

20%

15%

10%

5%

0%

J3J5

J7J12

J2

20/12,520/16

20/2020/25

20/32

20/25 & J5: 99.1%20/20 & J5: 94.5%

20/25 & J2: 80.0%20/20 & J2: 77.3%

Hyperopia

45%

40%

35%

30%

25%

20%

15%

10%

5%

0%

J3J5

J7J12

J2

20/12,520/16

20/2020/25

20/32

20/25 & J5: 99.3%20/20 & J5: 98.5%

20/25 & J2: 94.9%20/20 & J2: 94.9%

Myopia

20/25 & J5: 98.9%20/20 & J5: 97.7%

20/25 & J2: 92.0%20/20 & J2: 93.2%

45%

40%

35%

30%

25%

20%

15%

10%

5%

0%

J3J5

J7J12

J2

20/12,520/16

20/2020/25

20/32

Emmetropia

35%

30%

25%

20%

15%

10%

5%

0%

J3J5

J7J12

J2

20/12,520/16

20/2020/25

20/32

20/25 & J5: 99.1%20/20 & J5: 94.5%

20/25 & J2: 80.0%20/20 & J2: 77.3%

Hyperopia

45%

40%

35%

30%

25%

20%

15%

10%

5%

0%

J3J5

J7J12

J2

20/12,520/16

20/2020/25

20/32

20/25 & J5: 99.3%20/20 & J5: 98.5%

20/25 & J2: 94.9%20/20 & J2: 94.9%

Myopia

Precisionforpresbyopicpatients Laser Blended Vision

The next stage of

Eye Care Excellence

A growing group of patients is reaching

presbyopic age. The Laser Blended Vision

option of the CRS-Master® optimally pre-

pares you for this trend. The software

assists you in planning binocular treat-

ments for the MEL 80™ andoptimizing

them for presbyopic patients. In this

way,individualizedtreatmentplanning

has reached the next stage of Eye Care

Excellence.

Improved quality of vision*

The principle: the great depth of focus

of the ablation profile in both eyes and

the true binocular approach produce an

overlap in the field of focus for medium

distances. Laser Blended Vision improves

the reading ability in the non-dominant

eye.

Scientific studies have shown that this

procedure also achieves a high degree

of tolerance compared with classical

monovision.

It was also shown that average binocular

distance visual acuity is better than the

visual acuity in the ‘distance eye’. This

suggests a constructive matching of

both images in the brain.

* Sources: Reinstein DZ, Archer TJ, Gobbe M, LASIK for Myopic Astigmatism and Presbyopia Using Non-linear Aspheric Micro-monovision With the Carl Zeiss Meditec MEL 80® Platform, in: Journal of Refractive Surgery, 2011 Jan; 27(1): 23–37.

Reinstein DZ, Archer TJ, Couch DG, LASIK for Hyperopic Astigmatism and Presbyopia Using Micro-monovision With the Carl Zeiss Meditec MEL 80® Platform, in: Journal of Refractive Surgery, 2009 Jan; 25: 23–37. Reinstein DZ, Laser Blended Vision: Using the most "natural" optical language of the visual system for treating presbyopia (Presentation), ESCRS Vienna 2011.

Combined Binocular Distance and Near UCVA*

Emmetropia Binocular Vision

Myopia BV

Myopia Binocular Vision

% P

atients

Near VisionDista

nce Vision

% P

atients

Near VisionDista

nce Vision

% P

atients

Near VisionDista

nce Vision

Your advantages

Option can be combined with eye registration

K-value optimized ablation

Simple binocular treatment planning

Overall, 93.2 % of the emmetropic, 94.9 % of the myopic and 77.3 % of the hyperopic presbyopic patients showed the combination 20/20 far vision and at the same time J2 near vision (binocular).

8 9

Page 6: MEL 80 - BSCRS...patient management and best treatment results. Equipped to outperform Through the combined use of the pivoting patient supporting system between the VisuMax femtosecond

10 11

MEL 80 the excimer laser with the broadest performance scope

What your colleagues say

" Laser Blended Vision is very easy to use, all the surgeons in the

center use it without any difficulty. The enthusiasm of the oper-

ated patients is revealing of its efficiency..."

Dr. Yves Guldenfels, Expert Vision Center, Strasbourg

" Laser Blended Vision (LBV) is a logical approach to treating

presbyopicindividuals.Patientshaveremarkedonthecomfort-

able vision. Importantly, subjective assessment of visual quality

demonstrates minimal perceived problems for all ranges of vision.

The Laser Blended Vision module has been an important addition

to my practice and I now find myself recommending laser

corrections for patients who would previously have been guided

to have refractive lens exchange."

Dr. Patrick Versace, The Eye Institute, Sydney

" Laser Blended Vision, so that age is not anymore an obstacle."

Dr. Charvier, Dr. Donate, Centre Laser Vision Roosevelt, Lyon

Laser data

Type ArF excimer laser

Wavelength 193 nm

Frequency10 / 250 Hz depending on treatment mode

Aiming beam diode 650 nm (laser class 1)

Device data

Weight of basic device

approximately 260 kg, total

Dimensions (Laser, L x W x H)

155 x 80 x 149 cm

Footprint including patient supporting system(L x W x H)

314 x 180 x 149 cm

Power supply

100 V AC; 50 / 60 Hz; 17.5 A 120 V AC; 50 / 60 Hz; 14.6 A208 / 220 / 230 / 240 V AC; 50 / 60 Hz; 7.9 A

ApprovalCE mark as per Medical Device Directive 93/42/EEC

Gas supply1 integrated ArF-Premix cylinder 10 l

Power consumption max. 1600 W

Equipment

Surgical microscopeOPMI pico with integrated video camera

Eye trackingActive eyetracking, IR, 1000 fps, pupil and limbus

CCA+ (plume removal system)

Integrated in device

Spot scanning-parameters

Beam dimensions0.7 mm FWHM, Gaussian beam profile

PTK-treatment

Area ablation Programmed PTK shaping

Spot ablation PTK spot

Options

Pivoting slit lamp

Technical data

The benefits

Only flying-spot laser where the eyetracker´s response

time is shorter than the time between two consecutive

laser pulses.

Gentle treatment: extremely rapid recovery

of vision

Broadest portfolio of applications

Fastest available excimer/femtosecond

laser combination

Rapid workflow at the push of a button

No need for flushing gas systems and

extra gas cylinders

Simple fluence test

Intuitive software

Seamless data transfer to VisuMax®

Easy installation

Short start-up time

Ergonomically designed workstation

CCA+ plume removal system

Swivel-type patient supporting system

Page 7: MEL 80 - BSCRS...patient management and best treatment results. Equipped to outperform Through the combined use of the pivoting patient supporting system between the VisuMax femtosecond

Manufacturer:

Carl Zeiss Meditec AG Goeschwitzer Strasse 51–5207745 JenaGermanywww.meditec.zeiss.com/MEL80

Your local contact:

ArgentinaCarl Zeiss Argentina S.A.Calle Nahuel Huapi 4015 / 25C1430 BCO Buenos AiresArgentinaPhone: +54 11 45 45 66 [email protected]

AustraliaCarl Zeiss Pty Ltd Tenancy Office 4, Level 1 40-52 Talavera Road North Ryde NSW 2113 Australia Phone: +61 2 9020 1333 [email protected]

AustriaCarl Zeiss GmbHLaxenburger Str. 21100 ViennaAustriaPhone: +43 1 79 51 [email protected]

BelgiumCarl Zeiss NV-SAIkaroslaan 491930 ZaventemBelgiumPhone: +32 2 719 39 [email protected]

BrazilCarl Zeiss do Brasil Ltda.Av. Naçoes Unidas, 21711CEP04795-100 São PauloBrazilPhone: +55 11 5693 [email protected]

CanadaCarl Zeiss Canada Ltd.45 Valleybrook DriveToronto, ON M3B 2S6CanadaPhone: +1 800 387 [email protected]

ChinaCarl Zeiss Shanghai Co. Ltd.1/f., Ke Yuan Building11 Ri Yin Nan RoadWaigaoqiao Free Trade Zone2005 Yang Gao Bei RoadShanghai 200131ChinaPhone: +86 21 5048 17 [email protected]

Czech RepublicCarl Zeiss spol. s.r.o.Radlická 14/3201150 00 Prague 5Czech RepublicPhone: +420 233 101 [email protected]

FranceCarl Zeiss Meditec France SAS60, route de Sartrouville78230 Le PecqFrancePhone: +33 1 34 80 21 [email protected]

GermanyCarl Zeiss Meditec VG mbHCarl-Zeiss-Strasse 2273446 OberkochenGermanyPhone: +49 7364 20 [email protected] Ophthalmology:Phone: +49 800 470 50 [email protected]

Hong KongCarl Zeiss Far East Co. Ltd.Units 11-12. 25/FTower 2, Ever Gain PlazaNo. 88 Container Port RoadKwai ChungHong KongPhone: +852 2332 [email protected]

IndiaCarl Zeiss India Pvt. Ltd.22. Kensington RoadUlsoorBangalore 560 008IndiaPhone: +91 80 2557 88 [email protected]

ItalyCarl Zeiss S.p.A.Viale delle Industrie 2020020 Arese (Milan)ItalyPhone: +39 02 93773 [email protected]

JapanCarl Zeiss Meditec Japan Co. Ltd.Shinjuku KuTokyo 160-000322 Honchio-ChoJapanOphthalmic instruments:Phone: +81 3 33 55 [email protected] instruments:Phone: +81 3 33 55 [email protected]

MalaysiaCarl Zeiss Sdn Bhd.Lot2, Jalan 243/51 A46100 Petaling JayaSelangor Darul EhsanMalaysiaPhone: +60 3 7877 50 [email protected]

MexicoCarl Zeiss de México S.A. de C.V.Avenida Miguel Angel de Quevedo49604010 Mexico CityMexicoPhone: +52 55 59 99 [email protected]

NetherlandsCarl Zeiss B.V.Trapezium 300Postbus 3103364 DL SliedrechtNetherlandsPhone: +31 184 43 34 [email protected]

New ZealandCarl Zeiss NZ Ltd 15B Paramount Drive P.O. Box 121 - 1001 Henderson, Auckland 0650 Ph: +64 9 838 5626 [email protected]

PolandCarl Zeiss sp. Z o.o.ul. Lopuszanska 3202-220 WarsawPolandPhone: +48 22 858 [email protected]

SingaporeCarl Zeiss Ptd. Ltd.50 Kaki Bukit PlaceSingapore 415926SingaporePhone: +65 6741 [email protected]

South AfricaCarl Zeiss (Pty.) Ltd.363 Oak AvenueFerndaleRandburg 2194South AfricaPhone: +27 11 886 [email protected]

South KoreaCarl Zeiss Co. Ltd.Seoul 121-828Mapo-gu141-1, Sangsu-dong2F, BR Elitel Bldg.South KoreaPhone: +82 2 3140 [email protected]

SpainCarl Zeiss Meditec Iberia S.A.Ronda de Poniente, 15Tres Cantos28760 MadridSpainPhone: +34 91 203 37 [email protected]

SwedenCarl Zeiss ABTegeluddsvaegen 7610254 StockholmSwedenPhone: +46 84 59 25 [email protected]

SwitzerlandCarl Zeiss AGFeldbachstrasse 818714 FeldbachSwitzerlandPhone: +41 55 254 [email protected]

ThailandCarl Zeiss ThailandFloor 8, Thosapol Land Building 2230 Ratchadapisek RoadHuaykwang, Bangkok 10310ThailandPhone: +66 2 2 74 06 [email protected]

United KingdomCarl Zeiss Ltd.15-20 Woodfield RoadWelwyn Garden CityHertfordshire, AL7 1JQUnited KingdomPhone: +44 1707 [email protected]

United States of AmericaCarl Zeiss Meditec, Inc.5160 Hacienda DriveDublin, CA 94568USAPhone: +1 925 557 [email protected]

Publ

icat

ion

No:

000

000-

1986

-611

Pr

inte

d in

Ger

man

y CZ

-I/20

12Th

e co

nten

ts o

f the

bro

chur

e m

ay d

iffer

from

the

curre

nt s

tatu

s of

app

rova

l of t

he p

rodu

ct in

you

r cou

ntry

. Ple

ase

cont

act o

ur re

gion

al re

pres

enta

tive

for m

ore

info

rmat

ion.

Subj

ect t

o ch

ange

in d

esig

n an

d sc

ope

of d

eliv

ery

and

as a

resu

lt of

ong

oing

tech

nica

l dev

elop

men

t. Pr

inte

d on

ele

men

tal c

hlor

ine-

free

blea

ched

pap

er.

© 2

012

by C

arl Z

eiss

Med

itec

AG. A

ll co

pyrig

hts

rese

rved

.

0297