mecom elg programming
TRANSCRIPT
![Page 1: Mecom ELG programming](https://reader036.vdocuments.site/reader036/viewer/2022082812/55ba5a37bb61eb2b348b46fa/html5/thumbnails/1.jpg)
ELG – Easy Programming
Ericsson LG
Unified Communication for Advanced Business Needs
Visit: www.ericssonlg.com
www.mecomdubai.com
![Page 2: Mecom ELG programming](https://reader036.vdocuments.site/reader036/viewer/2022082812/55ba5a37bb61eb2b348b46fa/html5/thumbnails/2.jpg)
Basic Techniques
Default SettingsDefault IP: 10.10.10.2
Subnet: 255.255.255.0
Switch 1, 2, 3 & 4 OFF (restart to have factory reset)
DIP switch 1 – OFF to make changes in the software
DIP switch 4 – OFF to keep the program in memory
On system running mode - keep switch 2&3 in ON position and 1&4 in OFF position
Remember to take program software backup after major changes
![Page 3: Mecom ELG programming](https://reader036.vdocuments.site/reader036/viewer/2022082812/55ba5a37bb61eb2b348b46fa/html5/thumbnails/3.jpg)
Basic Techniques
Web Accesshttps://10.10.10.2
To have http://10.10.10.2
Login to program mode on 24 button telephone
PGM * # PGM then the program number.
change the following
PRG 160 Flex 22 – make it OFF
PRG 161 Flex 14 – web port 0080
Change Country Code PRG100 to UAE
keep (DIP switch 1,2,3 in ON and 4 OFF) for the setup.
![Page 4: Mecom ELG programming](https://reader036.vdocuments.site/reader036/viewer/2022082812/55ba5a37bb61eb2b348b46fa/html5/thumbnails/4.jpg)
Basic Techniques
Telephone Access
To make changes or reset telephone to factory defaults
Press * on start up
login password 147*
Press volume up or down to reach the specifics
Make changes and press SAVE
![Page 5: Mecom ELG programming](https://reader036.vdocuments.site/reader036/viewer/2022082812/55ba5a37bb61eb2b348b46fa/html5/thumbnails/5.jpg)
Basic Techniques
Primary Basic MUST Date & Time (178) Change Trunk Priority (160-161) item 4 Caller ID (114 - 1 & 2) Trunk Ringing assignment (144) Trunk access and grouping (140-142, 117)
![Page 6: Mecom ELG programming](https://reader036.vdocuments.site/reader036/viewer/2022082812/55ba5a37bb61eb2b348b46fa/html5/thumbnails/6.jpg)
Basic Techniques
Trunk Access
Toll Exception table (224, 116)
For Trunks
CO COS 1: Station COS applies
CO COS 2: Exception Table A governs
CO COS 3: Exception Table B governs
CO COS 4: Restricts LD calls and Exception Table C
CO COS 5: Overrides Station COS
![Page 7: Mecom ELG programming](https://reader036.vdocuments.site/reader036/viewer/2022082812/55ba5a37bb61eb2b348b46fa/html5/thumbnails/7.jpg)
Basic Techniques
Trunk Access Toll Exception table (224, 116) - Settings for Extns:
1 - No restrictions are placed on dialing from the station.
2 - The assignments in Exception Table A are monitored for allow and deny numbers.
3 - The assignments in Exception Table B are monitored for allow and deny numbers.
4 - The assignments in both Exception Tables A & B are monitored for allow and deny numbers
5 - The leading digit dialed cannot be a Long Distance code, default “0” or “1”, and further denied/allowed based on Exception Table C.
![Page 8: Mecom ELG programming](https://reader036.vdocuments.site/reader036/viewer/2022082812/55ba5a37bb61eb2b348b46fa/html5/thumbnails/8.jpg)
Basic Techniques
Trunk Access (Cont..)6 - The leading digits dialed cannot be a Long Distance code & digit count cannot exceed the LD digit counter, default 7 digits, and further denied/allowed based on Exc., Table C.
7 - Intercom and paging calls are allowed. No outgoing dialing except for emergency calls is allowed on CO Lines.
8 - The assignments in the Exception Table D are monitored for allow and deny numbers.
9 - The assignments in the Exception Table E are monitored for allow and deny numbers
10 - The assignments in the Exception Table D & E are monitored for allow and deny numbers
11 - The assignments in the Exception Table A & B and D & E are monitored for allow and deny numbers.
![Page 9: Mecom ELG programming](https://reader036.vdocuments.site/reader036/viewer/2022082812/55ba5a37bb61eb2b348b46fa/html5/thumbnails/9.jpg)
PRI Programming - Incomming
Matched with MSN Table Entry ?
NO
YES
TYPE 1(Use ‘as is’)(ex. 1100 => 1100)
Ring toMatched NumberingDestination
Remove digits from start of incomng DID Number
DecideDAY/NIGHT/TIMEDBy Auto Ring Mode Table Index
TYPE 2 (Modify using Flexible)
TYPE 0 (DID Conversion)
DID DGT Conversion
YES
NO
PGM 202
PGM 143 –DID Remove Number
PGM 143 –COLP Table IndexPGM 201 –COLP Table Value
PGM 145 –Number of Digits Expected (from First)/ Digit Mask(ex. 1100 => 110)
Remove DID Digit Set ?
DID Call
ICLI (Incoming CLI) Usage ON ?
PGM 231- ICLID Table Usage
YES
NO
Ring to ICLID Destination
PGM 203/204 – Destination
PGM 231- Auto Ring Mode Table
PGM 231- Destination
Ring to Flexible DID Destination
Remove Matched String setBy CorrespondingCOLP TBL Index and Data
PGM 145 –DID Conversion Type
Ring toMatched NumberingDestination
DID Digit Conversion Type ?
DID DGT Conversion
PGM 145 –Number of Digits Expected (from Last)/ Digit Mask(ex. 1100 => 100)
![Page 10: Mecom ELG programming](https://reader036.vdocuments.site/reader036/viewer/2022082812/55ba5a37bb61eb2b348b46fa/html5/thumbnails/10.jpg)
Auto Attendant & Voice Mail Auto Attendant: VSF access (112 - 36) enabled extension VRS: CCR Table (228), Voice Mail Dialing table (234)
From enabled extension Phone
• Press Trans/PGM
• Dial 0 + 6
• Enter System Message Number (i.e. 001)
• REC Type is 1
• Press # To Start Recording (wait to listen current recording)
• Record your NEW Greeting
• Press Hold/Save to END Recording
Recording from PC VSG tab > Individual upload > file format > 1_5.wav (1 is default and 5 is message number)