mechanical intro 14.5 appa buckling

Upload: sullivan-fg

Post on 10-Feb-2018

243 views

Category:

Documents


1 download

TRANSCRIPT

  • 7/22/2019 Mechanical Intro 14.5 AppA Buckling

    1/34

    2012 ANSYS, Inc. December 19, 20121 Release 14.5

    Introduction to ANSYS

    Mechanical

    14.5 Release

    Appendix A

    Linear Buckling Analysis

  • 7/22/2019 Mechanical Intro 14.5 AppA Buckling

    2/34

    2012 ANSYS, Inc. December 19, 20122 Release 14.5

    Chapter OverviewIn this chapter, performing linear buckling analyses in Mechanical will be covered.

    Contents:

    A. Background On Buckling

    B. Buckling Analysis Procedure

    C. Workshop 7-1

  • 7/22/2019 Mechanical Intro 14.5 AppA Buckling

    3/34

  • 7/22/2019 Mechanical Intro 14.5 AppA Buckling

    4/34

    2012 ANSYS, Inc. December 19, 20124 Release 14.5

    Background on Buckling

    Eigenvalue or linear buckling analysispredicts the theoretical buckling strength of

    an ideal linear elasticstructure.

    This method corresponds to the textbook approach of linear elastic buckling

    analysis.

    The eigenvalue buckling solution of a Euler column will match the classical Euler solution.

    Imperfections and nonlinear behaviors prevent most real world structures fromachieving their theoretical elastic buckling strength.

    Linear buckling generally yields unconservativeresults by not accounting for these

    effects.

    Although unconservative, linear buckling has the advantage of beingcomputationally cheap compared to nonlinear buckling solutions.

  • 7/22/2019 Mechanical Intro 14.5 AppA Buckling

    5/34

    2012 ANSYS, Inc. December 19, 20125 Release 14.5

    Basics of Linear Buckling

    For a linear buckling analysis, the eigenvalue problem below is solved to get the

    buckling load multiplier liand buckling modes yi:

    Assumptions:

    [K] and [S] are constant: Linear elastic material behavior is assumed

    Small deflection theory is used, and nononlinearities included

    It is important to remember these assumptions related to performing linear

    bucklinganalysesin Mechanical.

    0ii

    SK yl

  • 7/22/2019 Mechanical Intro 14.5 AppA Buckling

    6/34

    2012 ANSYS, Inc. December 19, 20126 Release 14.5

    B. Buckling Analysis Procedure

    A Static Structural analysis will need to be performed prior to (or in conjunction

    with) a buckling analysis.

  • 7/22/2019 Mechanical Intro 14.5 AppA Buckling

    7/34 2012 ANSYS, Inc. December 19, 20127 Release 14.5

    Geometry and Material Properties

    Any type of geometry supported by Mechanical may be used in buckling analyses:

    Solid bodies

    Surface bodies (with appropriate thickness defined)

    Line bodies (with appropriate cross-sections defined)

    Only buckling modes and displacement results are available for line bodies.

    Although Point Masses may be included in the model, only inertial loads affect point

    masses, so the applicability of this feature may be limited in buckling analyses

    For material properties, Youngs Modulus and Poissons Ratio are required as a

    minimum

  • 7/22/2019 Mechanical Intro 14.5 AppA Buckling

    8/34 2012 ANSYS, Inc. December 19, 20128 Release 14.5

    Contact Regions

    Contact regions are available in free vibration analyses, however,

    contact behavior will differ for the nonlinearcontact types

    exactly as with modal analyses.

    Discussed earlier (see chapter 5).

    Initially Touching Inside Pinball Region Outside Pinball Region

    Bonded Bonded Bonded Free

    No Separation No Separation No Separation Free

    Rough Bonded Free Free

    Frictionless No Separation Free Free

    Contact TypeLinear Buckling Analysis

  • 7/22/2019 Mechanical Intro 14.5 AppA Buckling

    9/34 2012 ANSYS, Inc. December 19, 20129 Release 14.5

    Loads and Supports

    At least one structural load, which causes buckling, should be applied to the

    model: Allstructural loads will be multiplied by the load multiplier (l)to determine the buckling

    load (see below).

    Compression-only supports are not recommended.

    The structure should be fully constrained to prevent rigid-body motion.

    F x l = Buckling Load

    In a buckling analysis all appliedloads (F) are scaled by a

    multiplication factor (l) until thecritical (buckling) load is reached

  • 7/22/2019 Mechanical Intro 14.5 AppA Buckling

    10/34 2012 ANSYS, Inc. December 19, 201210 Release 14.5

    Loads and Supports

    Special considerations must be given if constant andproportional loads are

    present.

    The user may iterate on the buckling solution, adjusting the variable loads until the load

    multiplier becomes 1.0 or nearly 1.0.

    Consider the example of a column with self weight WOand an externally applied forceA.

    A solution can be reached by iterating while adjusting the value ofAuntil l= 1.0. Thisinsures the self weight = actual weight or WO* l WO .

  • 7/22/2019 Mechanical Intro 14.5 AppA Buckling

    11/34

    2012 ANSYS, Inc. December 19, 201211 Release 14.5

    Buckling SetupBuckling analyses are always coupled to a structural analysis within the project

    schematic.

    The Pre-Stress object in the tree contains the results from a structural analysis.

    The Details view of the Analysis Settings under the Linear Buckling branch allows theuser to specify the number of buckling modes to find.

  • 7/22/2019 Mechanical Intro 14.5 AppA Buckling

    12/34

    2012 ANSYS, Inc. December 19, 201212 Release 14.5

    Solving the Model

    After setting up the model the buckling analysis can be solved along with the static

    structural analysis.

    A linear buckling analysis is more computationally expensivethan a static analysis on the

    same model.

    The Solution Information branch provides detailed solution output.

  • 7/22/2019 Mechanical Intro 14.5 AppA Buckling

    13/34

    2012 ANSYS, Inc. December 19, 201213 Release 14.5

    Reviewing ResultsAfter the solution is complete, the buckling modes can be reviewed:

    The Load Multiplier for each buckling mode is shown in the Details view as well as the

    graph and chart areas. The load multiplier times the applied loads represent thepredicted buckling load.

    Fbuckle= (Fappliedx l)

  • 7/22/2019 Mechanical Intro 14.5 AppA Buckling

    14/34

    2012 ANSYS, Inc. December 19, 201214 Release 14.5

    Reviewing Results

    Interpreting the Load Multiplier (l): The tower model below has been solved twice. In the first case a unit load is applied. In

    the second an expected load applied (see next page)

  • 7/22/2019 Mechanical Intro 14.5 AppA Buckling

    15/34

    2012 ANSYS, Inc. December 19, 201215 Release 14.5

    Reviewing Results

    Interpreting the Load Multiplier (l):

    LoadUnitadBucklingLo _*l

    l adBucklingLo

    LoadActualadBucklingLo _*l

    FactorSafetyLoadActual

    adBucklingLo_

    _

    l

  • 7/22/2019 Mechanical Intro 14.5 AppA Buckling

    16/34

    2012 ANSYS, Inc. December 19, 201216 Release 14.5

    Reviewing Results

    The buckling load multipliers can be reviewed in the Timeline section of the

    results under the Linear Buckling analysis branch

    It is good practice to request more than one buckling mode to see if the structure may be

    able to buckle in more than one way under a given applied load.

  • 7/22/2019 Mechanical Intro 14.5 AppA Buckling

    17/34

    2012 ANSYS, Inc. December 19, 201217 Release 14.5

    C. Workshop AA.1Linear Buckling

    Workshop WSAA.1Linear Buckling

    Goal:

    Verify linear buckling results in Mechanical for the pipe model

    shown below. Results will be compared to closed form

    calculations from a handbook.

    http://localhost/var/www/apps/conversion/tmp/ANSYS_Mechanical-Intro_12.1_1st-edition/Workshops/WB-Mech_120_WS_07.1.ppthttp://localhost/var/www/apps/conversion/tmp/ANSYS_Mechanical-Intro_12.1_1st-edition/Workshops/WB-Mech_120_WS_07.1.ppthttp://localhost/var/www/apps/conversion/tmp/ANSYS_Mechanical-Intro_12.1_1st-edition/Workshops/WB-Mech_120_WS_07.1.ppthttp://localhost/var/www/apps/conversion/tmp/ANSYS_Mechanical-Intro_12.1_1st-edition/Workshops/WB-Mech_120_WS_07.1.ppthttp://localhost/var/www/apps/conversion/tmp/ANSYS_Mechanical-Intro_12.1_1st-edition/Workshops/WB-Mech_120_WS_07.1.ppthttp://localhost/var/www/apps/conversion/tmp/ANSYS_Mechanical-Intro_12.1_1st-edition/Workshops/WB-Mech_120_WS_07.1.ppthttp://localhost/var/www/apps/conversion/tmp/ANSYS_Mechanical-Intro_12.1_1st-edition/Workshops/WB-Mech_120_WS_07.1.ppt
  • 7/22/2019 Mechanical Intro 14.5 AppA Buckling

    18/34

    2012 ANSYS, Inc. December 19, 201218 Release 14.5

    GoalsThe goal in this workshop is to verify linear buckling results in ANSYS Mechanical.

    Results will be compared to closed form calculations from a handbook.

    Next we will apply an expected load of 10,000 lbf to the model and determine its

    factor of safety.

    Finally we will verify that the structures material will not fail before buckling

    occurs.

  • 7/22/2019 Mechanical Intro 14.5 AppA Buckling

    19/34

    2012 ANSYS, Inc. December 19, 201219 Release 14.5

    Assumptions

    The model is a steel pipe that is assumed to be fixed at one end and

    free at the other with a purely compressive load applied to the

    free end. Dimensions and properties of the pipe are:

    OD = 4.5 in ID = 3.5 in. E = 30e6 psi, I = 12.7 in^4, L = 120 in.

    In this case we assume the pipe conforms to the following handbookformula where P is the critical load:

    For the case of a fixed / free beam the parameter K = 0.25.

    2

    2

    'L

    IEKP

  • 7/22/2019 Mechanical Intro 14.5 AppA Buckling

    20/34

    2012 ANSYS, Inc. December 19, 201220 Release 14.5

    Assumptions

    Using the formula and data from the previous page we can

    predict the buckling load will be:

    lbfeP 3.65648)120( 771.1263025.0' 22

  • 7/22/2019 Mechanical Intro 14.5 AppA Buckling

    21/34

    2012 ANSYS, Inc. December 19, 201221 Release 14.5

    Project Schematic1. Double click Static Structural in the

    Toolbox to create a new system.

    2. Drag/drop a Linear Buckling systemonto the Solution cell of the staticstructural system.

    2.

    1.

  • 7/22/2019 Mechanical Intro 14.5 AppA Buckling

    22/34

    2012 ANSYS, Inc. December 19, 201222 Release 14.5

    When the schematic is correctly set up it should appear as shown

    here.

    The drop target from the previous page indicates the outcome ofthe drag and drop operation. Cells A2 thru A4 from system (A) are

    shared by system (B). Similarly the solution cell A6 is transferred to

    the system B setup. In fact, the structural solution drives the

    buckling analysis.

    Project Schematic

    Drop Target

  • 7/22/2019 Mechanical Intro 14.5 AppA Buckling

    23/34

    2012 ANSYS, Inc. December 19, 201223 Release 14.5

    Project SchematicVerify that the Project units are set to US Customary (lbm, in, s, F, A, lbf, V).

    Verify units are set to Display Values in Project Units.

  • 7/22/2019 Mechanical Intro 14.5 AppA Buckling

    24/34

    2012 ANSYS, Inc. December 19, 201224 Release 14.5

    3. From the static structural system (A),double click the Engineering Data cell.

    4. To match the hand calculations referencedearlier, change the Youngs modulus of thestructural steel.

    a. Highlight Structural Steel.b. Expand Isotropic Elasticity and modify

    Youngs Modulus to 3.0E7 psi.

    c. Return to Project.

    Note : changing this property here does not affect thestored value for Structural Steel in the General Materiallibrary. To save a material for future use we wouldExport the properties as a new material to the materiallibrary.

    . . . Project Schematic

    3.

    b.

    a.

    c.

  • 7/22/2019 Mechanical Intro 14.5 AppA Buckling

    25/34

    2012 ANSYS, Inc. December 19, 201225 Release 14.5

    . . . Project Schematic5. From the static structural system (A),

    RMB the Geometry cell and Import

    Geometry. Browse to the filePipe.stp.

    6. Double click the Model cell to start

    Mechanical.

    When the Mechanical application opens the tree

    will reflect the setup from the project schematic.

    5.

    6.

  • 7/22/2019 Mechanical Intro 14.5 AppA Buckling

    26/34

    2012 ANSYS, Inc. December 19, 201226 Release 14.5

    Preprocessing7. Set the working unit system to the U.S. customary

    system:

    a. U.S. Customary (in, lbm, psi, F, s, V, A).

    8. Apply constraints to the pipe:

    a. Highlight the Static Structural branch (A5).

    b. Select the surface on one end of the pipe.

    c.RMB > Insert > Fixed Support.

    a.

    b.

    a.

    c.

  • 7/22/2019 Mechanical Intro 14.5 AppA Buckling

    27/34

    2012 ANSYS, Inc. December 19, 201227 Release 14.5

    Environment9. Add buckling loads:

    a. Select the surface on the opposite end of the pipe from the

    fixed support.

    b. RMB > Insert > Force.

    c. In the force detail change the Define by field toComponents.

    d. In the force detail enter 1 in the Magnitude field for the

    Z Component (or use -1 depending on which ends of thepipe are selected).

    c.

    d.

    a.

    b.

  • 7/22/2019 Mechanical Intro 14.5 AppA Buckling

    28/34

    2012 ANSYS, Inc. December 19, 201228 Release 14.5

    . . . Environment10. Solve the model:

    a. Highlight the Solution branch for the Linear Buckling analysis

    (B6) and Solve.

    Note, this will automatically trigger a solve for the

    static structural analysis above it.

    11. When the solution completes:

    a. Highlight the buckling Solution branch (B6).

    The Timeline graph and the Tabular Data will display

    the 1stbuckling mode (more modes can be requested).

    b. RMB in the Timeline and choose Select All.

    c. RMB > Create Mode Shape Results (this will add a TotalDeformation branch to the tree).

    c.

    b.

    a.

    a.

  • 7/22/2019 Mechanical Intro 14.5 AppA Buckling

    29/34

    2012 ANSYS, Inc. December 19, 201229 Release 14.5

    Click Solve to view the first mode

    Results

  • 7/22/2019 Mechanical Intro 14.5 AppA Buckling

    30/34

    2012 ANSYS, Inc. December 19, 201230 Release 14.5

    . . . Results12. Change the force value to the expected load (10000

    lbf):

    a. Highlight the Force under the Static Structural (A5)branch

    b. In the details, change the Z Component of the forceto 10000 (or use -10000 depending on your selections).

    13. Solve:

    a. Highlight the Linear Buckling Solution branch (B6),RMB and Solve.

    11b.

    11a.

    12a.

  • 7/22/2019 Mechanical Intro 14.5 AppA Buckling

    31/34

    2012 ANSYS, Inc. December 19, 201231 Release 14.5

    . . . ResultsWhen the solution completes note the Load Multiplier field now shows a value

    of 6.56. Since we now have a real world load applied, the load multiplier is

    interpreted as the buckling factor of safety for the applied load.

    Given that we have already calculated a buckling load of 65600 lbf, the result is

    obviously trivial (65600 / 10000). It is shown here only for completeness.

  • 7/22/2019 Mechanical Intro 14.5 AppA Buckling

    32/34

    2012 ANSYS, Inc. December 19, 201232 Release 14.5

    VerificationA final step in the buckling analysis is added here as a best practices exercise.

    We have already predicted the expected buckling load and calculated the factor of

    safety for our expected load. The results so far ONLY indicate results as they

    relate to buckling failure. To this point we can say nothing about how our

    expected load will affect the stresses and deflections in the structure.

    As a final check we will verify that the expected load (10000 lbf) will not cause

    excessive stresses or deflections before it is reached.

  • 7/22/2019 Mechanical Intro 14.5 AppA Buckling

    33/34

    2012 ANSYS, Inc. December 19, 201233 Release 14.5

    . . . Verification14. Review Stresses for 10,000lbf load:

    a. Highlight the Solution branch under the Static

    Structural environment (A6).b. RMB > Insert > Stress > Equivalent Von Mises Stress.

    c. RMB > Insert > Deformation > Total.

    d. Solve.

    a.

    b.

    c.

  • 7/22/2019 Mechanical Intro 14.5 AppA Buckling

    34/34

    . . . VerificationA quick check of the stress results shows the model as loaded is well within the

    mechanical limits of the material being used (Engineering Data shows

    compressive yield = 36,259 psi).

    As stated, this is not a required step in a buckling analysis but should be regarded

    as good engineering practice.