mech
DESCRIPTION
lab manualTRANSCRIPT
-
ME 2405-Mechatronoics Lab Manual
Name :
Reg No :
Branch :
Year & Semester :
Page 1 of 55
-
TABLE OF CONTENTS
S.No. Date Name of the experiment
Page Marks
Staff Remarks
No initial
Control the single acting
1. and double acting cylinders
using pilot valves
Continuous reciprocating of
2.
single acting and double
acting cylinder using pilot
valves
Designing a pneumatic
3.
circuit for the sequence
a+b-a-b
Electro pneumatic control of
4.
double acting cylinder using
SPDT and pushbutton
switch
Actuation of single acting
5. cylinder using ON and OFF
delay timer
PLC control of single acting
6. cylinders ON and OFF delay timer
Automatic actuation of
7. double acting cylinder using
PLC
PLC control of sequencing
8. circuit using PLC ladder
diagram
9.
Design of pneumatic circuit
using pneumosim software
-
10.
Design of hydraulic circuit
using hydrosim software
11.
Servo motor using open
loop system
Servo motor using closed loop system
12.
Study of 8051 13. microcontroller and stepper motor
Run the stepper motor
at 14. different speed and different direction
Run the stepper motor
in 15. forward and reverse
direction
16.
Hydraulic linear actuation
trainer
17.
Real time temperature
controller
Multi process station
current 18. to pressure transmitter and flow transmitter
Page 3 of 55
-
CONTROL THE SINGLE ACTING AND DOUBLE ACTING CYLINDERS USING PILOT VALVES
Expt. No.: Date: AIM: To actuate single and double acting cylinders in a pneumatic circuit. APPARATUS REQUIRED:
1. Single acting cylinder
2. 3/2 push button spring return DCV
3. 3/2 single pilot valve
4. 5/2 single, double pilot DCV
5. Air service unit
6. Connecting tubes CIRCUIT DIAGRAM-SINGLE ACTING CYLINDER.
Page 4 of 55
-
DOUBLE ACTING CYLINDER WITH 5/2 SINGLE PILOT VALVE CIRCUIT DIAGRAM-DOUBLE ACTING CYLINDER WITH 5/2 DOUBLE PILOT
VALVE
Page 5 of 55
-
PROCEDURE:
1. The connection is made as shown in figure.
2. The pilot pressure are fed into the 3/2 direction control valve.
3. When the button is pushed the air is sent into single acting cylinder.
4. The cylinder moves in forward position.
5. When the push button is released, it retracts because of the spring.
6. Feed the air through different valves and make the cylinder to actuate.
RESULT:
Thus the cylinders are actuated by the air pressure in the pneumatic circuit.
Page 6 of 55
-
CONTINUOUS RECIPROCATING OF SINGLE ACTING AND DOUBLE ACTING CYLINDER USING PILOT VALVES
Expt. No.: Date: AIM: To actuate a single and double acting cylinders using pilot valves APPARATUS REQUIRED:
1. Double acting cylinder
2. 3/2 single pilot DCV
3. 5/2 single pilot DCV
4. 5/2 double pilot DCV
5. 3/2 roller lever valves
6. FRL unit
7. Connecting tubes CIRCUIT DIAGRAM-SINGLE ACTING CYLINDER:
Page 7 of 55
-
PROCEDURE:
SINGLE ACTING CYLINDER:
1. The circuit is given as shown in figure.
2. Connect the compressed air supply to FRL unit
3. Check the all circuit
4. Open the hand slide valve
5. Observe the working of continuous running single acting cylinder
CIRCUIT DIAGRAM-DOUBLE ACTING CYLINDER-5/2 DOUBLE PILOT VALVE
Page 8 of 55
-
DOUBLE ACTING:
1. Draw the circuit diagram
2. connect compressor air supply to FRL unit
3. Connect any one of the outputs of FRL unit to 5/2 direction control unit port 1
4. Connect port 4 of DCV to blank end of the double acting cylinder
5. Connect the output of FRL unit to the input of two 3/2 roller lever valves to give
pilot pressure for 5/2 double pilot valve
6. The output of the two roller valves are connected to the either side of the 5/2
double pilot valve properly.
7. When the FRL valve is opened the higher pressure air enters the blank end of
the cylinder through DCT and the piston moves forward.
8. At the end of the forward stroke the piston rod pressures the roller valve. The
output of roller valve is sent to double acting cylinder to change the position.
9. Now the high pressure air from FRL unit is sent to rod end of the double acting
cylinder through the second position of the DCV the piston retracts.
10. At the end of return stroke the roller valve is pressed. The output of the roller
valve is sent to dc change the piston. This is repeated until the FRL valve is closed.
RESULT:
Thus the continuous reciprocating of single and double acting cylinders are actuated by
the air pressure in the pneumatic circuit.
Page 9 of 5
-
DESIGNING A PNEUMATIC CIRCUIT FOR THE SEQUENCE A+B-A-B Expt. No.: Date: AIM
To design a circuit for the sequence A+B A-B APPARATUS REQUIRED
1. Single and Double acting cylinder
2. 3/2 single pilot DCV
3. 5/2 single pilot DCV
4. 5/2 double pilot DCV
5. 3/2 roller lever valves
6. FRL unit
7. Connecting tubes CIRCUIT DIAGRAM:
Page 10 of 55
-
PROCEDURE:
1. Draw the circuit diagram.
2. Connect the compressor air to FRL unit
3. Air both outputs of FRL unit connected to all components.
4. Test your all circuits.
5. Open the hand slide valve.
6. Observe the working of cylinders. RESULT:
The circuit diagram for the sequence is drawn and executed.
Page 11 of 55
-
ELECTRO PNEUMATIC CONTROL OF DOUBLE ACTING CYLINDER USING SPDT
AND PUSHBUTTON SWITCH Expt. No.: Date: AIM: To develop a electro-pneumatic circuit for extension and retraction of double acting cylinder APPARATUS REQUIRED:
1. Double acting cylinder
2. 3/2 solenoid valve
3. 5/2 single and double solenoid valve
4. FRL unit
5. Relay
6. SPDT Switch
7. Pushbutton switch
8. Connecting tubes & wires
9. Data Card CIRCUIT DIAGRAM-SPDT SWITCH
-
PROCEDURE: SPDT SWITCH
1. Provide power supply to the pneumatic trainer from control trainer by
interfacing 24+vand-v
2. Using the SPDT switch energize the corresponding solenoid valve to get the
desired movement in the cylinder.
3. Supply the Air to FRL unit.
4. Assemble all the components.
5. Check all the connections carefully.
6. Test the circuit. Observe the working of the cylinder using the 3/2 and 5/2 solenoid valve. CIRCUIT DIAGRAM-PUSH BUTTON
PUSHBUTTON SWITCH:
1. Draw the circuit diagram and connect the air supply to FRL unit.
2. Connect the electrical circuit from 24 dc source to ON/OFF switch.
3. Solenoids are connected to the pushbutton switch.
Page 13 o
-
4. When the solenoid is given a signal solenoid are cut and the solenoids are de-
energized and the DCV activated to single and double acting cylinder.
5. When off button is pressed the signal solenoid are cut and the solenoids are de-
energized and the DCV comes to the original position.
RESULT:
Thus the movement of double acting cylinder was carried out using switches.
-
ACTUATION OF SINGLE ACTING CYLINDER USING ON AND OFF DELAY TIMER Expt. No.: Date: AIM: To develop an electro-pneumatic circuit for the activation of single acting cylinder using timer. APPARATUS REQUIRED
1. single acting cylinder
2. 3/2 single solenoid valve
3. Slide valve
4. FRL unit
5. Connecting tubes & wires CIRCUIT DIAGRAM-ON TIMER
Page 15 of 5
-
PROCEDURE: ON DELAY TIMER
1. Provide power supply to electrical controller by interfacing the +ve to ve and
ve to -ve
2. Provide power supply to pneumatic trainer for electrical controller by
interfacing 24+ve to +ve and ve to ve.
3. Using the SPDT switch energize the corresponding solenoid to get the
desired movement of the cylinder
4. Actual the time delay circuit.
5. From time delay, give connection to single acting cylinder to actuate the
cylinder according to time set.
6. Design and draw the pneumatic circuit.
7. Connect the air supply.
8. Test the circuit
9. Observe the working of the cylinder.
Circuit diagram-OFF TIMER
Page 16 of 55
-
OFF DELAY TIMER
1. Provide Power supply to pneumatic trainer from electrical controller by
interfacing +24V and -24V
2. Provide 24V power supply to timer
3. Any one of the outputs of FRL unit is directly connected to 3/2 single solenoid valve.
4. Single solenoid valve output is connected to single acting cylinder.
5. Give +24V and -24V in timer
6. Output of Timer is connected to solenoid coil.
7. Check the all circuit
8. Observe the working of cylinder
9. Observe the working circuit.
RESULT:
Thus the movement of single acting cylinder was carried out using time delay.
Page 17 of 55
-
Einstein College of Engineering
-
PLC CONTROL OF SINGLE ACTING CYLINDERS ON AND OFF DELAY TIMER
Expt. No.: Date: AIM:
To design a circuit to extend and retract the single acting cylinder with the help of delay timer controlled by PLC.
APPARATUS REQUIRED: 1. Single acting cylinder 2. RS 232 cable 3. Versa pro software 4. 3/2 single solenoid valve 5. FRL unit 6. PLC 7. Connecting wires and tube CIRCUIT DIAGRAM:-ON DELAY TIMER
Page 18 of 55
-
PROCEDURE: ON DELAY TIMER: 1. Draw the circuit diagram 2. Provide +24V and 24V from PLC trainer to panel. 3. Open the versa pro software in desktop 4. Interface PLC with PC using RS 232 cable. 5. Write a ladder diagram. 6. Output of PLC (q1) is directly connected to input of solenoid coil. 7. Following the opening procedure of versa pro software. 8. Check the ladder diagram. 9. Connect the air supply to FRL unit. 10. Run the PLC. After some delay the cylinder will be activated. CIRCUIT DIAGRAM-OFF DELAY TIMER
Page 19 of 55
-
OFF DELAY TIMER 1. Draw the circuit diagram 2. Provide +24V and 24V from PLC trainer to panel. 3. Open the versa pro software in desktop 4. Interface PLC with PC using RS 232 cable. 5. Write a ladder diagram. 6. Output of PLC (q1) is directly connected to input of solenoid coil. 7. Following the opening procedure of versa pro software. 8. Check the ladder diagram. 9. Connect the air supply to FRL unit. 10. Run the PLC and observe the working of single acting cylinder.
RESULT:
Thus the actuation of single acting cylinder with ON and OFF delay timer
was done using PLC.
Page 20 of 55
-
AUTOMATIC ACTUATION OF DOUBLE ACTING CYLINDER USING PLC
Expt. No.: Date: AIM
To simulate the automatic sequence of double acting cylinder using PLC
APPARATUS REQUIRED
1. Double acting cylinder
2. RS 232 cable
3. versa pro software
4. 5/2 double solenoid valve
5. FRL unit
6. PLC
7. Connecting wires and tube. CIRCUIT DIAGRAM
Page 21 of 55
-
PROCEDURE:
1. Draw the circuit diagram
2. Provide +24V and 24V from PLC trainer to panel.
3. Open the versa pro software in desktop
4. Interface PLC with PC using RS 232 cable.
5. Write a ladder diagram.
6. Both outputs of PLC (q1 and q2) are directly connected to inputs of solenoid coils.
7. Following the opening procedure of versa pro software.
8. Check the ladder diagram.
9. Connect the air supply to FRL unit.
10. Run the PLC and observe the working of double acting cylinder.
RESULT:
Thus the ladder diagram for the automatic running of double acting cylinder is drawn and executed.
Page 22
-
PLC CONTROL OF SEQUENCING CIRCUIT USING PLC LADDER DIAGRAM
Expt. No.: Date: AIM
To design a circuit for the sequence A+B+A-B using PLC
APPARATUS REQUIRED:
1. Single and Double acting cylinder
2. RS 232 cable
3. versa pro software
4. 3/2 single solenoid valve ,5/2 double solenoid valve
5. FRL unit
6. PLC
7. Connecting wires and tube CIRCUIT DIAGRAM:
Page 23 of 55
-
PROCEDURE:
1. Draw the circuit diagram
2. Provide +24V and 24V from PLC trainer to panel.
3. Open the versa pro software in desktop
4. Interface PLC with PC using RS 232 cable.
5. Write a ladder diagram.
6. Outputs of PLC (q1, q2, q3 and q4) are directly connected to the inputs of solenoid coil.
7. Following the opening procedure of versa pro software.
8. Check the ladder diagram.
9. Connect the air supply to FRL unit.
10. Run the PLC and observe the working of double acting cylinder.
RESULT:
Thus the ladder diagram for the automatic running of double acting cylinders is designed and
executed.
Page 24 of 55
-
DESIGN OF PNEUMATIC CIRCUIT USING PNEUMOSIM SOFTWARE
Expt. No.: Date: AIM: To simulate the pneumatic circuit with single acting, double acting cylinders by manual
and automatic mode using pneumatic simulation software
REQUIREMENTS:
1. Personal Computer
2. PHEUMOSIM Software PROCEDURE:
1. Open the software in the personal computer.
2. Select the new file in it.
3. Click on the supply elements and then select, copy, paste the compressor .
4. Click the attenuator and then select copy, paste the single and double acting cylinder.
5. Then select, copy, paste the 3/2, 5/2 single and double solenoid valve.
6. Select the air supply unit.
7. Connect all the components.
8. Start and operate the single, double acting cylinders.
Page 25 of 55
-
RESULT:
Thus the Pneumatic circuit for single acting, double acting cylinder was simulated
using PNEUMOSIM software.
Page 26 of 55
-
DESIGN OF HYDRAULIC CIRCUIT USING HYDROSIM SOFTWARE
Expt. No.: Date: AIM: To simulate the hydraulic circuit with single acting, double acting cylinders by manual and
automatic mode using hydraulic simulation software
REQUIREMENTS:
1. Personal Computer
2. HYDROSIM Software
PROCEDURE:
1. Open the software in the personal computer.
2. Select the new file in it.
3. Click on the supply elements and then select, copy, paste the pump and tanks.
4. Click the attenuator and then select, copy, paste the single and double
acting cylinder.
5. Then select, copy, paste the 3/2, 5/2 single and double solenoid valve.
6. Connect all the components
7. Start and operate the single, double acting cylinders.
Page 27 of 55
-
RESULT:
Thus the Hydraulic circuit for single acting, double acting cylinder was simulated using
HYDROSIM software.
Page 28 of 55
-
SERVO MOTOR USING OPEN LOOP SYSTEM
Expt. No.: Date: AIM:
To study the performance of servomotor control for open loop system
REQUIREMENTS:
1. Servo motor
2. PLC
3. Win Pro Ladder
4. PC
5. connecting cables
6. Patch chords PROCEDURE:
1. Load the Win pro ladder and software to the PC.
2. Open the PLC trainer.
3. Connect the PLC & servo controller kit.
4. Open the new folder and draw the ladder logic diagram.
5. Connect the drive & PC.
6. Set the Speed and direction and other drivers.
7. Connect the PLC and PC.
8. Run the program.
Page 29 of 55
-
RESULT: Thus the Performance of the servo motor was studied for open loop system.
Page 30 of 55
-
SERVO MOTOR USING CLOSED LOOP SYSTEM
Expt. No.: Date: AIM:
To study the performance of servomotor control for closed loop system
REQUIREMENTS:
1. Servo motor
2. PLC
3. Win Pro Ladder
4. PC
5. connecting cables
6. Patch chords PROCEDURE:
1. Load the Win pro ladder and software to the PC
2. Open the PLC trainer
3. Connect the PLC & servo controller kit
4. Open the new folder and draw the ladder logic diagram
5. Connect the drive & PC
6. Set the Speed and direction and other drivers
7. Connect the PLC and PC
8. Run the program
Page 31 of 55
-
RESULT:
Thus the Performance of the servo motor was studied for closed loop system
Page 32 of 55 \
-
STUDY OF 8051 MICROCONTROLLER AND STEPPER MOTOR Expt. No.: Date: AIM:
The study the fundamentals of 8051 microcontrollers and stepper motor. MICROCONTROLLER: A microcontroller is an integration of a microprocessor with memory and input, output
interfaces and other peripherals such as timers on a single chip.
A microcontroller may take an input from the device it is controlling and control the
device by sending signals to different components in the device.
A microcontroller is often small and low cost. The components may be chosen to
minimize size and to be as inexperience as possible.
Another name for a microcontroller is embedded controller. They can control
features or action of the product. Register in microcontroller:
A microcontroller contains a group of registers each type of register having a
different functions. Accumulator:
The accumulator (A) is an 8 bit register where data for an input to the arithmetic
and logic unit is temporarily stored. So the accumulator register is a temporary handling
register for data to be operated on by the arithmetic and logic unit also after the operation
the register for holding the result. B Register:
In addition to accumulator an 8 bit B-register is available as a general purpose
register when it is not used for the hardware multiply/divide operation. Data pointer (DPTR):
The data pointer consists of a high byte (DPH) and a low byte (DPL). Its function is
to hold a 16 bit address. It may be manipulated as a 16 bit data register. It serves as a
base register in direct jumps, lookup table instructions and external data transfer.
Page 33 of 55
-
Stack pointer:
The stack refers to an area of internal RAM that is used in conjunction with certain
opcode data to store and retrieve data quickly. The stack pointer register is used, by the
8051 to hold as internal RAM that is called top of stock. The stack pointer register is 8 bit
wide. It is increased before data is stored during PUSH and CALL instructions and
decremented after data is restored during POP and RET instruction. The stack pointer is
initialized to 07H after a reset. This causes the stack to begin at location 08H. Program counter:
The 8051 has 16 bit program counter. It is used to hold the address of memory location
from which the instruction to be fetched. 8051 is a 16 bit hence it can be address up to 216
byte
i.e. 64k of memory. The PC is the only register that does not have an internal address. Internal RAM:
The 8051 has 128 bytes internal RAM. It is addressed using RAM address register
First thirty two bytes from address 00H to 1FH of internal RAM constitute 32
working registers. They organized into four banks of eight registers each. The
four register banks are numbered 0 to 3 and consist of eight registers named
R0 to R7. Each register can be addressed by name or by its RAM address. Only one register bank is in use at a time. Bits Rs0 and Rs1 in the PSW
determine which bank of register is currently in use. Register banks when not selected can be used as general purpose RAM.
PIN diagram of microcontroller:
The 8051 microcontroller is available in a 40 pin dual in-line (DIL) package arrangement. It
is important to note that many pins of 8051 are used for more than one function.
The function of each of the pins is as follows. PORT 0 (pins 32-39):
Port 0 pins can be used as I/O pins. The output drives and input buffers of port 0
are used to access external memory address, time multiplexed with the data being written
or read. Thus port 0 can be used as multiplexed address data bus. PORT 1 (pins 1-8):
Port 1 pins can be used only as I/O pins. PORT 2 (pins 21-28):
Page 34 of 55
-
The output drives of port 2 are used to access external memory. Port 2 outputs the
high order byte of the external memory address when the address is 16 bits wide
otherwise port 2 is used as I/O ports. PORT 3 (pins 10-17):
All ports pins of port-3 are multifunctional. They have special functions including
two external interrupts two counter two special data lines and two timing control strobes.
Power supply pins Vcc and ground to pin Vcc with rated power supply current of 125mA. Oscillator Pins XTA2 (pin 18) and XTA1 (pin 19):
For generating an internal clock signal the external oscillator is connected at these two pins. ALE (address latch enable) Pin 30:
AD0 to AD7 lines are multiplexed. To determine these lines and for obtaining lower
half of an address, an external latch and ALE of 8051 is used. RST (Reset pin 9):
This pin is used to reset 8051. For proper reset operation, reset signal must be held
high at least for two machine cycles, while oscillator is running. PSEN (Program Store Enable pin29):
It is the active low output control signal used to activate the enable signal if the
external ROM/EPROM. It is activated every six oscillator periods while reading the
external memory. Thus this signal acts as the read store to external program memory. STEPPER MOTOR A motor in which the rotor is able to assume only discrete stationary angular position is a stepper
motor. The rotary motion occurs in a stepwise manner from one equilibrium position to the next. Construction features:
A stepper motor could be either of the reluctance type of or permanent magnet type. A PM
motor consists of multiphase stator and two part permanent magnet rotor variable reluctance motor
has magnetized rotor. PM stepper motor is the most commonly used type. The basic two phase
stepper motor consists of two pairs of stator poles. Each of four poles has its own winding. The
excitation of any one winding generates a north pole and a South Pole gets attracted and the
torque induced at the diametrically opposite side. The rotor magnetic system has two end faces.
The left face is permanently magnetized as south and the right face as North Pole faces.
Page 35 of 55
-
The north pole structure is twisted with respect to the south pole structure so that south
pole precisely between two north poles. In an arrangement where there are four stator poles and
three pairs of rotor poles, there exist 12 possible stable position in which a south pole if the rotor
can lock with a north pole of the stator. From this is can be noted that the step size is
= 360 (Ns*Nr)
Ns number of stator pole
Nr number of pairs of rotor poles
Generally step size of the stepper motor depends up on rotor poles. There are
three different schemes available for stepping a motor. They are
1. wave scheme 2. 2 phase scheme 3. half stepping or missed scheme
Wave switching scheme:
Anticlock wise Clock wise
Step A1 A2 B1 B2 Step A1 A2 B1 B2
1 1 0 0 0 1 1 0 0 0
2 0 0 0 1 2 0 0 1 0
3 0 1 0 0 3 0 1 0 0
4 0 0 1 0 4 0 0 0 0
Two phase switching scheme:
Anticlock wise Clock wise
Step A1 A2 B1 B2 Step A1 A2 B1 B2
1 1 0 0 1 1 1 0 1 0
2 0 1 0 1 2 0 1 1 0
3 0 1 1 0 3 0 1 0 1
4 1 0 1 0 4 1 0 0 1
-
Operational features of stepper motor:
There are many kinds of stepper motor like unipolar type, bipolar type, single phase type,
multiphase type; single phase stepper motor is often used for quartz watch. In PM type stepper
motor, a permanent magnet is used for motor and coils are put on stator. The stepper motor
model which has 4 poles at top and bottom and at either sides. X coil, X coil, r coil and r coil are
put to the upper side and the lower pole. r coil and r coil are rolled up for the direction of the pole
becomes opposite when applying an electric current to the r coil. It is similar about X and X too.
The turn of the motor is controlled by the electric current which pairs into X, X, r, r. The rotor
rotational speed and the direction of turn can be controlled by this control. Speed control of a stepper motor:
The requirement is to use a microcontroller to drive a stepper motor in both forward and
reverse directions of shaft rotation and to implement a two speed arrangement switches
are to be used to produce the two speeds and a reversal of shaft rotation.
Generally a stepper motor has four sets of coils; one end of each coil may be connected
together and then connected to DC supply. The remaining four ends may be driven through
transistors either separately or in integrated circuit form. A four bit code sequence continuously
applied to the drive circuit from the microcontroller port causes the motor shaft to rotate in angular
steps. Stepper motor have step angles of 1.8 degree step revolution and turning force may be
improved by using a step down gear box. The stepping code sequence may be obtained from the
motor manufacturer or distributor. The program in this example was a common four step
sequence of A,9,5,6 that it sent continuously would cause the motor shaft to rotate.
RESULT:
Thus the fundamentals of microcontroller and stepper motor were studied.
Page 37 of 55
-
RUN THE STEPPER MOTOR AT DIFFERENT SPEED AND DIFFERENT DIRECTION
Expt. No.: Date: AIM:
To run a stepper motor at different speed and different direction by using 8051
assemble language APPARATUS REQUIRED:
1. Stepper Motor
2. Interface Board
PROCEDURE:
1. Switch ON the micro controller
2. Initialize the starting address
3. Enter the mnemonics code in the microcontroller
4. Reset the microcontroller
5. Execute the program
PROGRAM:
Address Label Instruction Opcode
4100 ORG 4100H
4100 START MOV DPTR, #4500H
4103 MOV R0, #04
4105 J0 MOVX A, @DPTR
4106 PUSH DPH
4108 PUSH DPL
410A MOV DPTR, #FFCOH
410D MOV R2, #04H
Page 38 of 55
-
410F MOV R1, #FFH
4111 DLY 1 MOV R3, #FFH
4113 DLY DJNZ R3, DLY
4115 DJNZ R1, DLY1
4117 DJNZ R2, DLY1
4119 MOV @DPTR, A
411A POP DPL
411C POP DPH
411E INC DPTR
411F DJNC R0 ,J0
4121 SJMP START
4123 END
4500 TABLE DB 09, 05, 06, 0A
RESULT:
Thus the program to run the stepper motor at different speed and different direction was
derived using 8051 assemble language and was verified.
Page 39 of 55
-
RUN THE STEPPER MOTOR IN FORWARD AND REVERSE DIRECTION
Expt. No.: Date: AIM:
To run a stepper motor in forward and reverse rotation using 8051 assembly language APPARATUS REQUIRED:
1. Stepper Motor
2. Interface Board
PROCEDURE:
1. Switch ON the micro controller
2. Initialize the starting address
3. Enter the mnemonics code in the microcontroller
4. Reset the microcontroller
5. Execute the program
PROGRAM:
Address Label Instruction Opcode
4100 ORG 4100H
4100 START: MOV R4, #33H
4102 L2: DPTR, #FORWARD
4105 L1
4108 R4, L2
410A DELAY
Page 40 of 55
-
410D R4, #33H
410F L3: DPTR, #REVERSE
4112 L1
4115 R4, L3
4117 DELAY
411A START
411C L1: R0, #04H
411E LOOP : A,@DPTR
411F 83H
4121 82H
4123 DPTR, #OFFCOH
4126 R2, #04H
4128 L7: R1, #05H
412A L6: R3, #OFFH
412C L4 : R3, L4
412E R1, L6
4130 R2, L7
4132 @DPTR ,A
4133 82H
4135 83H
4137 DPTR
4138 R0, LOOP
413A
413B DELAY : R5, #01H
Page 41 of 55
-
413D L9 : R2, #05H
413F L8: R2, L8
4141 R5, L9
4143 RET
4144 FORWARD DB 09H,05H,06H,0AH
:
4148 REVERSE : DB 0AH,06H,05H,09H
RESULT:
Thus the program to rotate the stepper motor in forward and reverse direction was
derived using 8051 assemble language and was verified.
Page 42 of
-
HYDRAULIC LINEAR ACTUATION TRAINER
Expt. No.: Date: AIM:
To study the working of linear actuation system.
APPARATUS REQUIRED:
1. Linear actuation system
2. PLC
3. Verse pro software
4. PC
5. RS 232 cable
6. Patch chords CIRCUIT DIAGRAM:
Page 43 of 55
-
PROCEDURE:
1. Load the verse pro software to PC.
2. Open the verse pro software.
3. Switch ON PLC and linear actuation system.
4. Connect the PC and PLC.
5. Draw ladder logic diagram.
6. Download in PLC.
7. Run the program.
8. Check the performance of linear actuation system. SPEED:
Sl.No. Velocity up Flow Velocity down Flow
(cm/sec) (cm3/sec) (cm/sec) (cm
3/sec)
Page 44 of 55
-
FORCE:
Sl.No. Pressure Displayed force in Calculated force in % of error
(kg/cm
2)
kg kg
Force:
Model calculation:
(i) velocity = flow / area
area (a) = ( / 4) x (d2)
flow = velocity x area
Page 45 of 55
-
(ii) pressure in kg/cm2 = force in kg / area in
cm2 calculated force in kg =
% error =[ (displayed force calculated force) / (displayed force) ] x 100
=
=
RESULT:
Thus the working of hydraulic linear actuation system was studied by using
hydraulic linear actuation trainer.
Page 46 of 55
-
REAL TIME TEMPERATURE CONTROLLER
Expt. No.: Date:
AIM:
The Objective of the experiment is to control the temperature process.
REQUIREMENT:
1. VRTTC- 01 Unit
2. Microcontroller / PC
3. Heater Setup
RTD
4. PC Power chord & cable
CIRCUIT DIAGRAM: PROCEDURE:
1. Heater Power plug , Blower, RTD are connected in Back panel (VRTC 01)
connecters named as Heater, Blower, Sensor respectively
2. Switch 1 is provided to control the heater supply voltage either by manually or by
auto mode.
Page 47 of 55
-
3. If switch 1 is selected as int mode potentiometer provided to control heater
supply voltage (0-230V AC) manually.
4. If switch 1 selected as ext mode, potentiometer provided to control the Heater
supply Voltage (0-230V AC) manually.
5. Interfacing should be followed as 1st
pin Gnd, 2nd
pin ADC (Negative), 3rd
pin
ADC (Positive) ,DAC output fed at 4th
&5th
pin of 9 pin D connector.
6. Switch on the VRTTC 01 Unit.
7. Select any one of the control action (ON/OFF, PID) and enter the controller
parameters (Kp, Ki, Kd, DB)
8. Based on the optimum parameters, temperature reaches to designed level (30 C 100o
C)
9. For various set point, controller parameters, Observe the process response. Note:
Run the Blower for at-least 5 minutes after the experiment to cool the heater. Temperature is a slow and smooth process.
Page 48 of 55
-
Tabulation:
S.No Time (s) Temperature (oC)
RESULT:
Thus the controlling of real time temperature is done.
Page 49 of 55
-
MULTI PROCESS STATION CURRENT TO PRESSURE TRANSMITTER AND FLOW
TRANSMITTER
Expt. No.: Date: AIM:
To study the characteristics & working principle of current to pressure converter, control
valve and flow transmitter.
APPARATUS REQUIRED:
1. VMPA 62
2. Data Acquisition card / Digital Controller with cable.
3. PC with process control software
4. Patch chords.
Page 50 of 55
-
CIRCUIT DIAGRAM:
Diagram-1
Procedure:
1. Ensure the availability of Air.
2. Interface the data acquisition card or digital controller with process and PC.
3. Make the connections as per connection diagram 1.
4. Maintain Gauge (G2) pressure at 20 psi by using air regulator knob.
5. Switch ON VMPA 62 unit and Data Acquisition card with PC.
6. Invoke process control software.
7. Select Control >> Manual mode enter the controller power in the dialog box.
Page 51 of 55
-
8. Gradually vary the controller output from 0 to 100% and note down the current
reading and pressure reading (G3) and stem movement (%).
9. Tabulate the readings and draw the graph between current in MA Vs pressure in Psi.
10. Similarly, draw the graph between Pressure (G3) (Psi) Vs stem movement (%).
11. Conclude the behavior of Current to Pressure Converter and Control Valve. Model graph:
Tabulation:
S.No Controller Output Current Input Pressure Output Stem movement
(%)
(mA) (G3)
(%)
Page 52 of 55
-
FLOW TRANSMITTER:
Circuit diagram:
Diagram-2
HAND VALVE SETTINGS:
HV1 Partially Closed
HV2 Fully Opened
HV3 Fully Closed
HV4 Fully Closed
Page 53 of 55
-
HV5 Fully Opened
HV6 Fully Closed
HV7 Fully Opened
FLOW RANGE
Input (50-500) Lph
Output (4-20)mA
PROCEDURE
1. Ensure the availability of Air and Water.
2. Interface the data acquisition card or digital controller with process and PC.
3. Make the connections as per connection diagram 2.
4. Maintain Gauge (G2) pressure at 20 Psi by using air regulator knob.
5. Ensure the hand valve settings are correct.
6. Switch ON VMPA 62 unit and Data Acquisition card with PC.
7. Invoke process control software.
8. Select Flow/Control >> Manual mode and enter a controller output of 100%.
9. Switch ON the pump. Vary pump speed regulator to run pump at desired speed.
10. Gradually increase the flow (say in steps of 50 LPH) by varying the pump speed,
and note down the correct readings.
11. Switch OFF the Pump.
12. Draw the graph between flow Vs output current and conclude the behavior of the DPT.
Page 54 of 55
-
MODEL GRAPH
S.No Flow(LPH) Flow transmitter current Output(mA)
RESULT:
Thus the characteristics of the current to pressure converter, control valve and flow transmitter were studied.
Page 55 of 55