measurement and visual evaluation of fluorescent samples · senai/cetiqt colour institute ....

20
Measurement and visual evaluation of fluorescent samples R. Hirschler SENAI/CETIQT Colour Institute Workshop on Colorimetry, Graphic Arts and Colour Management 4 July 2013, University of Leeds, UK

Upload: buidat

Post on 07-Feb-2019

219 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Measurement and visual evaluation of fluorescent samples · SENAI/CETIQT Colour Institute . Workshop on Colorimetry, Graphic Arts and Colour Management. 4 July 2013, ... Slide 1 Author:

Measurement and visual evaluation of fluorescent samples

R. Hirschler

SENAI/CETIQT Colour Institute

Workshop on Colorimetry, Graphic Arts and Colour Management 4 July 2013, University of Leeds, UK

Page 2: Measurement and visual evaluation of fluorescent samples · SENAI/CETIQT Colour Institute . Workshop on Colorimetry, Graphic Arts and Colour Management. 4 July 2013, ... Slide 1 Author:

Non-fluorescent samples may be viewed under any light source and the results calculated for any source or illuminant

XYZ, L*a*b* or any derived quantity may be calculated for any light source or illuminant

Non-fluorescent samples Visual evaluation and measurement

Page 3: Measurement and visual evaluation of fluorescent samples · SENAI/CETIQT Colour Institute . Workshop on Colorimetry, Graphic Arts and Colour Management. 4 July 2013, ... Slide 1 Author:

Fluorescent samples absorb UV radiation and emit visible light

Fluorescent samples

Page 4: Measurement and visual evaluation of fluorescent samples · SENAI/CETIQT Colour Institute . Workshop on Colorimetry, Graphic Arts and Colour Management. 4 July 2013, ... Slide 1 Author:

From the Donaldson matrix of the bispectral measurement of a fluorescent specimen the TRF may be calculated for any desired

light source or illuminant

Fluorescent samples Measurement

Excitation wavelength (nm)

Ref

lect

ance

+ fl

uore

scen

ce

Emis

sion

wav

elen

gth

(nm

)

Page 5: Measurement and visual evaluation of fluorescent samples · SENAI/CETIQT Colour Institute . Workshop on Colorimetry, Graphic Arts and Colour Management. 4 July 2013, ... Slide 1 Author:

The other possible solution is to measure fluorescent samples under the same light source as that used for

visual evaluation

Fluorescent samples Visual evaluation and measurement

Page 6: Measurement and visual evaluation of fluorescent samples · SENAI/CETIQT Colour Institute . Workshop on Colorimetry, Graphic Arts and Colour Management. 4 July 2013, ... Slide 1 Author:

The viable practical solution is to have light sources both in visual systems and in instruments simulate a

standard CIE illuminant

Fluorescent samples Visual evaluation and measurement

ISO 3664:2009 compliant ISO 13655:2009 M1 compliant

Page 7: Measurement and visual evaluation of fluorescent samples · SENAI/CETIQT Colour Institute . Workshop on Colorimetry, Graphic Arts and Colour Management. 4 July 2013, ... Slide 1 Author:

The five standard specimens used in the visual range evaluation of daylight simulators, according to

CIE 51.2 / S 012

Fluorescent samples Evaluation of daylight simulators

MI-type evaluation of light sources: colour difference between pairs of metameric samples under the test source which show

DE*=0 under the reference illuminant

Page 8: Measurement and visual evaluation of fluorescent samples · SENAI/CETIQT Colour Institute . Workshop on Colorimetry, Graphic Arts and Colour Management. 4 July 2013, ... Slide 1 Author:

Spectral reflectance factor of the first two (of five) metameric specimens for the evaluation of D65 simulators in the visible

range by the CIE 51 method

Fluorescent samples Evaluation of daylight simulators

Page 9: Measurement and visual evaluation of fluorescent samples · SENAI/CETIQT Colour Institute . Workshop on Colorimetry, Graphic Arts and Colour Management. 4 July 2013, ... Slide 1 Author:

Spectral external radiant efficiency Q(λ’) for the three UV standards in the UV range by the CIE 51 method

Fluorescent samples Evaluation of daylight simulators

Page 10: Measurement and visual evaluation of fluorescent samples · SENAI/CETIQT Colour Institute . Workshop on Colorimetry, Graphic Arts and Colour Management. 4 July 2013, ... Slide 1 Author:

Total spectral radiance factor βT(λ)) for the three UV standards for illuminant D65 in the CIE 51 method

Fluorescent samples Evaluation of daylight simulators

Page 11: Measurement and visual evaluation of fluorescent samples · SENAI/CETIQT Colour Institute . Workshop on Colorimetry, Graphic Arts and Colour Management. 4 July 2013, ... Slide 1 Author:

ISO 3664:2009 and ISO 13655:2009 M1 Shall: 1.0 / 1.5 - Should 0.5 / 1.0

ASTM E0991: BB; ASTM D1729: BC

Fluorescent samples Evaluation of daylight simulators

CIE Quality Grade

Metamerism Index Mv or Mu

A ≤ 0.25 B > 0.25 to 0.50 C > 0.50 to 1.00 D > 1.00 to 2.00 E > 2.00

Page 12: Measurement and visual evaluation of fluorescent samples · SENAI/CETIQT Colour Institute . Workshop on Colorimetry, Graphic Arts and Colour Management. 4 July 2013, ... Slide 1 Author:

SPD of GTI D50 lamp X-series (3664:2000 compliant) : 0.88 / 2.50

Fluorescent samples Practical implementation: GTI fluorescent lamps

Page 13: Measurement and visual evaluation of fluorescent samples · SENAI/CETIQT Colour Institute . Workshop on Colorimetry, Graphic Arts and Colour Management. 4 July 2013, ... Slide 1 Author:

SPD of GTI D50 lamp E-series (3664:2009 compliant) : 0.84 / 1.20

Fluorescent samples Practical implementation: GTI fluorescent lamps

Page 14: Measurement and visual evaluation of fluorescent samples · SENAI/CETIQT Colour Institute . Workshop on Colorimetry, Graphic Arts and Colour Management. 4 July 2013, ... Slide 1 Author:

SPD of 3664:2009 compliant JUST Normlicht D50 lights CVL (LED): 0.84 / 1.40 – ProGraphics: 0.85 / 0.55

Fluorescent samples Practical implementation: JUST lamps

Page 15: Measurement and visual evaluation of fluorescent samples · SENAI/CETIQT Colour Institute . Workshop on Colorimetry, Graphic Arts and Colour Management. 4 July 2013, ... Slide 1 Author:

GTI E lamp compared to excitation (Mu = 1.20)

Fluorescent samples Practical implementation: different lamps

0.00

0.50

1.00

1.50

2.00

2.50

3.00

300 350 400 450 500 550 600 650 700 Q(λ

') Sp

ectra

l ext

erna

l rad

iant

effi

cien

cy /

SPD

Wavelength (nm)

UV standard 1

UV standard 2

UV standard 3

CIE D50

GTI E lamp

Page 16: Measurement and visual evaluation of fluorescent samples · SENAI/CETIQT Colour Institute . Workshop on Colorimetry, Graphic Arts and Colour Management. 4 July 2013, ... Slide 1 Author:

GTI E and JUST PG lamps compared to excitation

Fluorescent samples Practical implementation: different lamps

0.00

0.50

1.00

1.50

2.00

2.50

3.00

300 350 400 450 500 550 600 650 700 Q(λ

') Sp

ectra

l ext

erna

l rad

iant

effi

cien

cy /

SPD

Wavelength (nm)

UV standard 1

UV standard 2

UV standard 3

CIE D50

GTI E lamp

JUST ProGraphics

Page 17: Measurement and visual evaluation of fluorescent samples · SENAI/CETIQT Colour Institute . Workshop on Colorimetry, Graphic Arts and Colour Management. 4 July 2013, ... Slide 1 Author:

JUST CVL LED lamp (Mu = 1.40) compared to excitation

Fluorescent samples Practical implementation: different lamps

0.00

0.50

1.00

1.50

2.00

2.50

3.00

300 350 400 450 500 550 600 650 700 Q(λ

') Sp

ectra

l ext

erna

l rad

iant

effi

cien

cy /

SPD

Wavelength (nm)

UV standard 1

UV standard 2

UV standard 3

CIE D50

JUST CVL

2.46 – 1.51 – 0.23

Page 18: Measurement and visual evaluation of fluorescent samples · SENAI/CETIQT Colour Institute . Workshop on Colorimetry, Graphic Arts and Colour Management. 4 July 2013, ... Slide 1 Author:

KM FD-7 with VFS technology and X-Rite eXact LED resp. Gas-filled tungsten + UV LED

Implementation of ISO 13655:2009 M1

Fluorescent samples Measurement: KM FD-7 – X-Rite eXact & i1

Page 19: Measurement and visual evaluation of fluorescent samples · SENAI/CETIQT Colour Institute . Workshop on Colorimetry, Graphic Arts and Colour Management. 4 July 2013, ... Slide 1 Author:

1. Standards – ISO 3664:2009 and ISO 13655:2009 M1 are a good

compromise between the desirable and the viable; – CIE 51.2 / S 012 (ISO 23603:2005) needs to be updated

2. Visual evaluation – Fluorescent lamp and LED technology – Compliance to the (ISO) standard may or may not be

enough 3. Instrumental measurement

– Both the VFS (LED) and the Tungsten + UV LED technology are supposed to be ISO M1 conform

Fluorescent samples State of the art

Page 20: Measurement and visual evaluation of fluorescent samples · SENAI/CETIQT Colour Institute . Workshop on Colorimetry, Graphic Arts and Colour Management. 4 July 2013, ... Slide 1 Author:

Acknowledgements Thanks are due to

Bob McCurdy (GTI), Michael Gall (JUST Normlicht) and Claas Bickeböller (Konica-Minolta)

for kindly having provided data and figures.