Measure ‐ Control ‐ SwitchSolutions for HV‐MV PowerSwitch : SynchroTeq Product Line
VIZIMAX INC – Confidential – July 11, 2017
2
High performance measurement of Frequency, ROCOF, Phasors Standalone Analog Merging Units
Utility Grade Solutions for HV‐MV Power
Measure
Control
Switch
Inrush current limiters for power transformers and reactive loadsNew approaches for improved PFC and Voltage/VAR Control
Substation automation, remote operation, asset monitoring Switchgear Control Units
3
RightWON Satellite/Plus/Engine : Smart Substation ControllerAutomation + Monitoring + Alarm/Event management + Data gatewayFull support of industrial, energy, power gen and utility protocols Integrated web HMI + local SCADA functionality
SynchroTeq System Controlled switching and monitoring IEDsFor new and existing HV & MV switchgears, regardless of the makesInrush Current Limiters for power transformers & reactive loadsAdvanced switching of reactive loads in VAR compensation, Volt/VAR control, PFC, FACTS, in SVC, STATCOM and standalone applications
PMU / AMUIEEE C37.118 / IEC 61850‐9‐2LE compliant, IEC 61850 , IEC 60870‐5‐10x and ModBus TCP/UDP with RightWON companion product Resilient to harmonics, high‐performance in stressed power systemsFast & stable ROCOF calculation: 1.2 to 2 cycles typical, 3 cycles max.For local control, single phase, Micro‐Grid, islanding, PMS, power quality
Utility Grade Solutions for HV‐MV PowerMeasure
Control
Switch
4
Applications and Markets
Grid Connection of RES Wind, Solar & more
Metal, Mining, Cements, FurnacesAC‐DC Railways, HST
Power Generation:Hydro, CCGT, Coal, Genset
Power Electronics SVC/Statcom, Rectifiers,
Inverters, DrivesOil & Gas
On‐shore/Off‐shoreHV/MV SwitchgearsPower Transformers
TSO & DSO: Grid Stability, Efficiency, Power Quality, Clean Connection of
Consumers/GeneratorsEnergy & Battery Storage
Power Generation Power Grids
IndustryHV- MV Equipment
HV/MV Transfo & FACTSHVDC Substations
6
Highlights
Over 25 years in CSDs, applications and systemsSupport by dedicated CSD experts: [email protected] support thru a network of qualified & trained VARsRemote support via internet (https:// secured connection)CSDs used at 735kV (Hydro‐Quebec, Canada), 765kV & 1200 kV (PGCIL India), HVDC (Manitoba‐Hydro, Canada) among othersRugged solutions for HV & MV switchgears, compliance with international standards, worldwide certificationsFor new and existing switchgears, regardless of the makes
7
SynchroTeq® System Components 2017
SynchroTeq MV
VIZIMAX Unified Communication Services
SynchroTeq Simulation Libraries
Power Studies
Implementation
Controllers
SynchroTeqConfiguration Suite
Networking
SynchroTeq Plus
8
Upgrade, control & monitor standard HV & MV switchgears OPEN and/or CLOSE at any precise electrical instantsOperation times: accurate prediction & compensation
Target switching angles aredynamically determined for
optimal resultswith a variety of load types
and applications
CLOSE command
Interceptionuntil 3ms
before nextzero-crossing
Zero-crossingSync/Start
ControlDelay
SwitchgearOperation time
SynchroTeq® Controlled Switching Devices
(1) Screenshot : SynchroTeq Waveform/Digital Analyzer (Freeware)
ControlOutput
9
For new & existing switchgears ofall types and voltages…
… regardless of the makesUltimate Inrush Current LimiterFor control, monitoring and asset managementTransformers, FACTS, Lines, Cables
SynchroTeq Plus – UHV, EHV, HV Switchgears
10
SynchroTeq Plus – UHV, EHV, HV SwitchgearsFor New and Existing Circuit BreakersCPU‐demanding Apps and Complex Models
Transmission linesNumerous compensation channelsFast‐switching of reactive loads
Strong Engine, Web‐based OperationStores 2,000‐events and waveforms
Best‐in‐Class HV Transformer Energization:Residual Flux Calculation ModulesBushing Sensors for transformer voltage measurements
Additional Modules and Tools:Bypass / Redundancy ModuleDual SPSBO : dual supply DC outputsRe‐energization Advisory System (TRAS)OPC UA Server for SCADA and DCS inSubstations or in Central Sites
11
SynchroTeq Plus – Scalable Platform
Load side AC voltage
measurement
Bypass & Dual Outputs
LAN Plug‐Ins
Advanced CSDWeb‐based Monitoring
Fits in Substation’s Control House,or in Power Transformer’s Cabinetor in Circuit Breaker’s Cabinet
SynchroTeq™ Plus
12
SynchroTeq MV – MV SwitchgearsFor All MV Switchgears up to 69kV:
3‐p operated, w/ and w/o pole staggering1‐p operated
Various Apps and Loads:Reactive Loads, Single‐Phase Transformers, Three‐Phase Transformers and Advanced Switching of Reactive Loads
Strong Engine, Web‐Based Operation:500‐events and waveform storageSupports partially charged reactive loadsFast‐Switching of capacitor banks and filters
Best‐in‐Class MV Transformer Energization:MVX version w/ Residual Flux CalculationFor 1‐p and 3‐p operated Switchgears
OPC Server, Data Transfer for SCADA/DCS in Substations and Central Sites
13
SynchroTeq MV – Compact & Flexible
SynchroTeq™ MV
1, 2, 3 Phase ApplicationsSwitchgears ‐ C/Bs ‐ Reclosers
up to 69 kV
2 Compact Units for FACTS & Transformers
Advanced CSDWeb‐based Monitoring
14
Unified Communication Services ‐ OPC UA Servers
(1) All data exchanges are tunnelled and secure
15
Load Voltage
SynchroTeq Platforms – Side by Side
Applications SynchroTeq MVR SynchroTeq MVX SynchroTeq PlusSynchroTeq Plus
+ VL mea.
Discharged Capacitor Banks ‐ MSC / MSCDN
Shunt Reactors – MSR
Transformers (Peak Voltage)
Transformers (Residual Flux)
Transformers in Parallel (Residual Flux)
Transmission Lines
Partially Charged Capacitor Banks ‐ MSC/FLT
CB and a half (any kV level)
SynchroTeq PlusSynchroTeq MV
Up to 69kV Up to EHV and UHV
16
SynchroTeq vs Switchgear Types
Capacitor Banks ‐ MSC / MSCDN
Shunt Reactors – MSR
Transformers (Peak Voltage)
Transformers (Residual Flux)
Transformers in Parallel (Residual Flux, note 1)
Transmission Lines
(1) : Requires RWS 055000 or TRAS
ApplicationsThree Pole
Operation w/ Staggering
Circuit Breaker/Switchgear
Single Pole Operation
Three Pole Operation
Simultaneous
17
SynchroTeq – Key Factors in Switching Strategies
Applications Voltage Current Residual Voltage Residual Flux
Discharged Capacitor Banks ‐ MSC / MSCDN
Shunt Reactors – MSR
Transformers (Peak Voltage)
Transformers (Residual Flux) ‐ Note 1
Transformers in Parallel (Residual Flux) ‐ Note 2
Transmission Lines ‐ Note 3
Partially Charged Capacitor Banks ‐ MSC/FLT
CB and a half (whichever is the switched load)
Dynamically Calculated StrategyFixed Strategy
(1) Based on continuous voltage measurement (magnetic VT/PT) at transformer’s primary or secondary side, or using optional bushing sensors and junction box (2) Requires RWS 055000 or TRAS (3) SynchroTeq Plus is suitable for Uncompensated and Compensated Transmission Lines – Differences may apply according to the Line type
18
SynchroTeq in Action – Examples
(*) I/O channels and signals: see SynchroTeq Plus & SynchroTeq MV datasheets
19
SynchroTeq in Action – Examples
20
SynchroTeq in Action – Examples
21
SynchroTeq – Web‐based operation – Dashboard
(1) Internet link and Login : https://spdemo.vizimax.com/SynchroTalk.html#login
22
SynchroTeq – Web‐based operation – Status
23
SynchroTeq – Web‐based operation – Journal
Filters
Alarm Tag
Open Waveforms
Check Configuration
24
SynchroTeq – Waveform & Digital Analyzer
Voltage - Phase A
Residual Fluxes Phases A, B, C
AnalogChannels
DigitalChannels
(1) MV Switchgear, Power transformer & Inverter – Residual flux calculation
25
SynchroTeq – Waveform & Digital Analyzer
CursorsTime interval between CursorsControlled switching & switchgear data
Exportable data table
(1) MV Switchgear, Power transformer & Inverter – Switchgear Closing & Inrush current limitation
26
SynchroTeq Plus
SynchroTeq MVR MVX
Source AC voltage measurement 3 ‐‐‐‐‐‐‐‐‐ 1 ‐‐‐‐‐‐‐‐‐Load AC current measurement 3 ‐‐‐‐‐‐‐‐‐ 3 ‐‐‐‐‐‐‐‐‐Load AC voltage measurement 3 (Opt.) N/A 3DC control voltage compensation √ ‐‐‐‐‐‐‐‐‐ √ ‐‐‐‐‐‐‐‐‐Temperature compensation 4‐20mA ‐‐ RTD/4‐20ma‐‐Pressure compensation 3x4‐20mA ‐‐‐‐‐‐‐‐‐N/A‐‐‐‐‐‐‐Coil driver supervision √ ‐‐‐‐‐‐‐‐‐N/A‐‐‐‐‐‐‐Integrated bypass unit √ (Opt.) ‐‐‐‐‐‐‐‐‐N/A‐‐‐‐‐‐‐Web interface √ ‐‐‐‐‐‐‐‐‐ √ ‐‐‐‐‐‐‐‐Event/Waveform storage capacity 2000 ‐‐‐‐‐‐‐‐ 500 ‐‐‐‐‐‐‐
SynchroTeq – I/O Channels & Functions
27
2‐ Switchgear timing at commissioning
1‐ Factory compensation data of a test unit 3‐ Measurement of operatingconditions (Temp, Pressures…)
4 Predicted operation time calculations
Real time calculationConfiguration data – Compensation polynomials
SynchroTeq – Compensation Channels – Example
Example: Opening time vs Temperature
28
SynchroTeq Special Features
Power transformersEnergizing any vector group switched from MV or HV sideFor Single‐pole (1‐p) operated and Three‐pole (3‐p) operated CBs/switchgearsHV bushing sensors for Residual Flux Calculation in alternative to PT/VTTRAS or RWS 055000: energizing power transformers in parallelActive transformer monitoring, independent from CB/switchgear operation
Capacitor banks, Harmonic filtersFast switching of capacitor banks and filters, taking into account the residual charge trapped in capacitors
Circuit breakers in CB and a half configurationsTransmission Line/Power Transformer, Transmission Line/Shunt Reactor…RWS 055000 for SCADA/DCS: system parameterization and control
29
SynchroTeq Advanced Features
CB monitoringI2t electrical wear computing on close/open/trip operations
CSD – Engineering toolsEMTP‐RV SynchroTeq simulation libraries: power studies, power flow analysisPSCAD SynchroTeq simulation libraries SynchroTeq LV units for HIL (Hardware In the Loop) testing
Enhanced output moduleCB control output modules with source/sink/floating capabilities & CB coil supervisionSupport of Dual voltage configuration (different voltages for closing and tripping coils)
NetworkingMeasurement data sharing across multiple networked SynchroTeq Plus units
30
2) HV Bushing sensor
1) VT/PT at the primary or secondary side of the transformer The residual flux is calculated
from the transformer voltage
With additional Voltage Measurement Module
SynchroTeq™ Plus
SynchroTeq Plus – Residual Flux & Voltage
31
Vizimax Sensors (3x)Active Junction
BoxOptional Module for Voltage
Measurement
SynchroTeq Plus – Bushing Sensors
Alternative to HV/MV Voltage Measurement Transformers
32
Discussion – Q/A
ABS Electro
North AmericaLongueuil, Qc CanadaT: +1 450 679‐[email protected]
EMEA + RussiaBrusselsBelgiumT: +32 2 669 [email protected]
IndiaHyderabadIndiaT: +91 [email protected]
ChinaBeijingChinaT: +86 950 4047 [email protected]
Latin AmericaMedellín, AntioquiaColombiaT: +57 315 595‐[email protected]
Vizimax Inc. proprietary and confidential
Central EuropeBohinjska BistricaSloveniaT: +43 676 549 0499+386 70 191 555
Laurent [email protected]