me 300 pro · 2014. 5. 30. · mediaid inc. & amdl health are part of the opto circuits group p/n:...

2
amdl health Three Channel ECG Machine ME 300 Pro Key Features 4.3” inches high resolution TFT 3 Channels realtime print 12 leads ECG signals simultaneously acquisition 80mm Printer Paper width Internal Memory Rechargeable Lithium Battery

Upload: others

Post on 07-Feb-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

  • amdl health

    Three Channel ECG MachineME 300 Pro

    Key Features

    4.3” inches high resolution TFT

    3 Channels realtime print

    12 leads ECG signals simultaneously acquisition

    80mm Printer Paper width

    Internal Memory

    Rechargeable Lithium Battery

    ••

    •••

  • Advanced Micronic Devices Limited

    Phone: +91 80 42991800–855 Email: [email protected] Website: www.amdlcorp.comPinnacle Square, - Amarjyothi Layout, Domlur, Bengaluru 560071, India 154

    Mediaid Inc. & AMDL Health are part of the Opto Circuits Group

    P/N: 51030002500

    amdl health

    Contact us for support : 1800 103 1100

    Three Channel ECG Machine ME 300 ProTechnical Specifications

    315mm (L) x 215mm (W) x 75mm (H)

    1.6Kg

    Record

    AC 100-240V 50/60Hz

    60VA

    Company with IEC 60601-1 and IEC 60601-1-2

    4.3” Color TFT

    480x272 pixels

    100V~220V; 50Hz/60Hz

    11.1V, 2Ah rechargeable lithium battery

    Class I,

    Type CF, (There is defibrillation and pacing

    protection circuit)

    4000V

    40dots/mm

    ≥± 500mV

    100 groups of ECG data

    SD card or U disk

    PDF & XML

    30~350bpm

    ± 1bpm (average time :10s)

    Standard 12-Leads

    Floating and defibrillation protection

    < 10µA≥50M0.0Hz~150Hz (-3dbB)

    Time constant > 3.2s≥ 110db (with AC filter)≤ 15µVp-p

    Ω

    Recording way

    Recording paper

    Paper type

    Resolution

    Paper speed

    Accuracy

    Record format

    Thermal printing system

    80mm (Wide)

    Roll

    Vertical 8dot/mm

    Horizontal 40dot/mm

    5, 5.25, 10, 12.25, 25, 50mm/s

    Error:± 3%

    5% (X axis), 5%(Y axis)

    Manual, Auto 4x3, Auto 3x4+1,

    Auto 3x4, Auto 2x6+1, Auto 2x6,

    Auto 3-2+1, Auto 3-2, Rhythm

    Size and Weight

    Size

    Weight

    Power Supply

    Power Voltage

    Input Current

    Standard

    Display

    Type

    Resolution

    Battery

    AC power

    DC power

    Safety

    Product Safety type

    Isolation voltage

    Vertical resolution

    Enduring polarization voltage

    Data Storage

    Internal Memory

    External Memory

    Data format

    Heart Rate

    HR measurement range

    Accuracy

    Technical

    Lead

    Input way

    Patient leak current

    Input impedance

    Frequency response

    Time constant

    CMRR

    Noise level