mdpo dpp in tibia-fibula fractures fracture.pdf · lower shaft tibia-fibula fracture frame...

26
MDPO DPP in Tibia-Fibula Fractures

Upload: ngomien

Post on 07-Feb-2018

221 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: MDPO DPP in Tibia-Fibula Fractures Fracture.pdf · Lower Shaft Tibia-Fibula Fracture Frame Construct -Proximal block composed of two proximal closed circular rings (above fracture)

MDPO DPP in Tibia-Fibula

Fractures

Page 2: MDPO DPP in Tibia-Fibula Fractures Fracture.pdf · Lower Shaft Tibia-Fibula Fracture Frame Construct -Proximal block composed of two proximal closed circular rings (above fracture)

Mid-shaft Tibial-fibular Fracture

Page 3: MDPO DPP in Tibia-Fibula Fractures Fracture.pdf · Lower Shaft Tibia-Fibula Fracture Frame Construct -Proximal block composed of two proximal closed circular rings (above fracture)

Components Required

4 Compatible Circular

Rings for Midshaft

Tibial Fractures

Page 4: MDPO DPP in Tibia-Fibula Fractures Fracture.pdf · Lower Shaft Tibia-Fibula Fracture Frame Construct -Proximal block composed of two proximal closed circular rings (above fracture)

Components Required

Proximal Fixation Block

Distal Fixation Block

Page 5: MDPO DPP in Tibia-Fibula Fractures Fracture.pdf · Lower Shaft Tibia-Fibula Fracture Frame Construct -Proximal block composed of two proximal closed circular rings (above fracture)

Frame Construct :

External Components

1. Threated Rods

3.Fixation Bolt

4. Nut

2. Columns

5. Posts, Washers,

Threaded Sockets,

Rancho Cubes, Bolts

Page 6: MDPO DPP in Tibia-Fibula Fractures Fracture.pdf · Lower Shaft Tibia-Fibula Fracture Frame Construct -Proximal block composed of two proximal closed circular rings (above fracture)

Frame Construct: Internal

Components

Olive Wire

Smooth Wire

Bayonet Wires

Page 7: MDPO DPP in Tibia-Fibula Fractures Fracture.pdf · Lower Shaft Tibia-Fibula Fracture Frame Construct -Proximal block composed of two proximal closed circular rings (above fracture)

Frame Construct :

Fixation Devices

Wire Cutter, Tensioner, Wreches, Pliers

Page 8: MDPO DPP in Tibia-Fibula Fractures Fracture.pdf · Lower Shaft Tibia-Fibula Fracture Frame Construct -Proximal block composed of two proximal closed circular rings (above fracture)

Final Frame Construct

Proximal Fixation Block

Distal Fixation Block

Fracture Segment

Page 9: MDPO DPP in Tibia-Fibula Fractures Fracture.pdf · Lower Shaft Tibia-Fibula Fracture Frame Construct -Proximal block composed of two proximal closed circular rings (above fracture)

1. Building The Proximal

Fixation Block

Page 10: MDPO DPP in Tibia-Fibula Fractures Fracture.pdf · Lower Shaft Tibia-Fibula Fracture Frame Construct -Proximal block composed of two proximal closed circular rings (above fracture)

1. Building The Proximal

Fixation Block

Components:

1. Closed Circular Rings

2. Threaded Rods or Columns

Page 11: MDPO DPP in Tibia-Fibula Fractures Fracture.pdf · Lower Shaft Tibia-Fibula Fracture Frame Construct -Proximal block composed of two proximal closed circular rings (above fracture)

1. Building The Proximal

Fixation Block

• Marked assigned

holes for threaded

rods or columns.

• Each rod or

columns is

separated by 5 holes.

Page 12: MDPO DPP in Tibia-Fibula Fractures Fracture.pdf · Lower Shaft Tibia-Fibula Fracture Frame Construct -Proximal block composed of two proximal closed circular rings (above fracture)

1. Building The Proximal

Fixation Block

• Insert the threaded rods or

columns in the indicated

white circular hole

• Each rod or column is

separated by five holes for

a stable construct

1

2

3

4 5

Ro

ds

C

olu

mn

s

Page 13: MDPO DPP in Tibia-Fibula Fractures Fracture.pdf · Lower Shaft Tibia-Fibula Fracture Frame Construct -Proximal block composed of two proximal closed circular rings (above fracture)

2. Building The Distal

Fixation Block

• Insert the threaded rods or

columns in the indicated

white circular hole

• Each rod or column is

separated by five holes for

a stable construct

1

2

3

4 5

Ro

ds

C

olu

mn

s

Page 14: MDPO DPP in Tibia-Fibula Fractures Fracture.pdf · Lower Shaft Tibia-Fibula Fracture Frame Construct -Proximal block composed of two proximal closed circular rings (above fracture)

3. Connecting The Two

Fixation Blocks

3. Connect the previously constructed distal fixation block

(step 1) to the proximal fixation block (step 2)

Page 15: MDPO DPP in Tibia-Fibula Fractures Fracture.pdf · Lower Shaft Tibia-Fibula Fracture Frame Construct -Proximal block composed of two proximal closed circular rings (above fracture)

3. Connecting The Two

Fixation Blocks

- Attach the two fixation blocks

with four threaded rods and

corresponding nuts

Proximal

Distal

Page 16: MDPO DPP in Tibia-Fibula Fractures Fracture.pdf · Lower Shaft Tibia-Fibula Fracture Frame Construct -Proximal block composed of two proximal closed circular rings (above fracture)

4. Fitting the Frame to the

Extremity

•Utilize fluoroscopy to ensure proper placement of the frame with the fracture

placed between the proximal and distal blocks.

• Allow 2-3 finger widths of space between the extremity and the posterior

aspect of the tibia for post-operative edema expansion.

Page 17: MDPO DPP in Tibia-Fibula Fractures Fracture.pdf · Lower Shaft Tibia-Fibula Fracture Frame Construct -Proximal block composed of two proximal closed circular rings (above fracture)

5. Proximal Stabilization Wire

The first wire is a frontal plane wire placed lateral to medial on the tibia after distracting distally and correcting rotational and frontal plane deformity as much as possible

When throwing the proximal wire in the proximity of the fibular head care

must be taken to avoid the common peroneal nerve

Page 18: MDPO DPP in Tibia-Fibula Fractures Fracture.pdf · Lower Shaft Tibia-Fibula Fracture Frame Construct -Proximal block composed of two proximal closed circular rings (above fracture)

Distal Reference Wire

Distal wire is placed first in order to give a reference point with the ankle joint.

The wire should be placed from lateral to medial parallel to the ankle joint, this is done under fluoroscopy.

The wire is secured on one side and then tensioned properly.

The distal wire can now be used for traction and reduction of the fracture.

Page 19: MDPO DPP in Tibia-Fibula Fractures Fracture.pdf · Lower Shaft Tibia-Fibula Fracture Frame Construct -Proximal block composed of two proximal closed circular rings (above fracture)

Distraction-Reduction Technique

After rotational deformity

is addressed and

corrected the distal wire

is inserted and tensioned

The foot plate is then

distracted and manual

manipulation of the

fracture is used to assist

in reduction.

Page 20: MDPO DPP in Tibia-Fibula Fractures Fracture.pdf · Lower Shaft Tibia-Fibula Fracture Frame Construct -Proximal block composed of two proximal closed circular rings (above fracture)

The Leg is suspended by reference wires

Rectus alignment of

the limb within the

fracture

The fracture falls

within the working

segment of the

frame.

Page 21: MDPO DPP in Tibia-Fibula Fractures Fracture.pdf · Lower Shaft Tibia-Fibula Fracture Frame Construct -Proximal block composed of two proximal closed circular rings (above fracture)

Reduction Wires

-An olive wire is placed on the proximal fragment

depending on the orientation of the fracture to

facilitate reduction

Page 22: MDPO DPP in Tibia-Fibula Fractures Fracture.pdf · Lower Shaft Tibia-Fibula Fracture Frame Construct -Proximal block composed of two proximal closed circular rings (above fracture)

Distal Reduction Wire

A second olive reduction wire is placed parallel to the first reduction wire from the opposite side.

The wire is place 2 cm from the distal extent of the fracture

The two wire will work together to reduce the fracture

Attach but do not secure the wires to the frame.

Olive Wire

Page 23: MDPO DPP in Tibia-Fibula Fractures Fracture.pdf · Lower Shaft Tibia-Fibula Fracture Frame Construct -Proximal block composed of two proximal closed circular rings (above fracture)

Dual Olive Wire Tensioning

With one tensioner the proximal olive is used to

Reduce the proximal fragment anatomically and

Then locked and tensioned.

The distal wire is tensioned from the opposite side

Of the olive allowing the fracture segment to be

Translated medially.

Photo above demonstrates the reduction with the

Olive wire, once completed the olive side of the

Wire is secured and the wire is tensioned.

Page 24: MDPO DPP in Tibia-Fibula Fractures Fracture.pdf · Lower Shaft Tibia-Fibula Fracture Frame Construct -Proximal block composed of two proximal closed circular rings (above fracture)

Finalized Reduction

Page 25: MDPO DPP in Tibia-Fibula Fractures Fracture.pdf · Lower Shaft Tibia-Fibula Fracture Frame Construct -Proximal block composed of two proximal closed circular rings (above fracture)

Lower Shaft Tibial Fracture

Page 26: MDPO DPP in Tibia-Fibula Fractures Fracture.pdf · Lower Shaft Tibia-Fibula Fracture Frame Construct -Proximal block composed of two proximal closed circular rings (above fracture)

Lower Shaft Tibia-Fibula

Fracture Frame Construct

-Proximal block composed of two proximal

closed circular rings (above fracture)

- Distal block composed of one closed circular

ring (placed below fracture and above ankle

joint) and DP plate