Gas Detection
Terry Marshall [Manufacturing Technical]
Bournville/Birmingham. UK
-
8/8/2019 MBP Presentation Revision 1
2/26
Leak Management Strategy
CTB strategy is to identify system components which are about tomalfunction before they do and minimise the loss of hazardous,environmentally damaging substances.
CTB aims to improve the safety, reliability, productivity, andenvironmental impact of our process plants and building services
through predictive maintenance programmes leading to:
Better planned maintenance
Reduced machine downtime
Better use of in-house manpower
Lower overall maintenance costs
Enhanced quality of processed product and reduced waste
Potential lower insurance costs
-
8/8/2019 MBP Presentation Revision 1
3/26
-
8/8/2019 MBP Presentation Revision 1
4/26
Gas Detection Equipment Refrigerant Detectors
Bespoke Design [CFC/HCFC Dependant]
Unsuitable for Air, Nitrogen and other Fluids
Non Quantifiable Detection
Poor Sensitivity Detection Levels
Manual Data Collection
Manual Cost Analysis/Loss Levels
Dated Technology
-
8/8/2019 MBP Presentation Revision 1
5/26
-
8/8/2019 MBP Presentation Revision 1
6/26
SonicMan Leak Detector
-
8/8/2019 MBP Presentation Revision 1
7/26
Gas Detection- Instrument Diagnosis
Capability
Refrigeration/Air Conditioning Systems
Steam Compressed Air
Gas
Other Fluids [Ultrasonic Wave Generation Capability].
-
8/8/2019 MBP Presentation Revision 1
8/26
Gas Detection- Instrument Diagnosis
Capability
Refrigeration/Air Conditioning Systems
Steam
Compressed Air
Gas
Other Fluids [Ultrasonic Wave Generation Capability].
-
8/8/2019 MBP Presentation Revision 1
9/26
Case Studies
U Block [Manufacturing]
Bournville Birmingham.
United Kingdom
-
8/8/2019 MBP Presentation Revision 1
10/26
Refrigeration Systems
-
8/8/2019 MBP Presentation Revision 1
11/26
U1W No. 8 & 9 Refrigeration System
Isolation Valve [Condenser/Receiver]
Fluid: HFC-134A
Loss Rate 0.3m3/Hr Cost/Annum [2,500]
-
8/8/2019 MBP Presentation Revision 1
12/26
U1E Packing Refrigeration System
TEV Inlet Pipework
Fluid: HCFC-69L
Loss Rate 0.3m3/Hr Cost/Annum [2,500]
-
8/8/2019 MBP Presentation Revision 1
13/26
U2WChilled Water Refrigeration System
Compressor HP Gauge Line
Fluid: HCFC-22
Loss Rate 0.3m3/Hr Cost/Annum [1,500]
-
8/8/2019 MBP Presentation Revision 1
14/26
U2WChilled Water Refrigeration System
TEV Equalisation Pipework
Fluid: HCFC-22
Loss Rate 0.5m3/Hr Cost/Annum [1,800]
-
8/8/2019 MBP Presentation Revision 1
15/26
U3WChilled Water Refrigeration System
Air Cooled Condenser
Fluid: HFC-134a
Loss Rate 0.5m3/Hr Cost/Annum [2,800]
-
8/8/2019 MBP Presentation Revision 1
16/26
U4W Intense Process Cooling Refrigeration System
Oil Separator Flanged Connection
Fluid: HCFC-22
Loss Rate 0.3m3/Hr Cost/Annum [2,500]
-
8/8/2019 MBP Presentation Revision 1
17/26
U5EChilled Water Refrigeration System
Oil SeparatorLeak
Fluid: HFC-134a
Loss Rate 0.3m3/Hr Cost/Annum [2,500]
-
8/8/2019 MBP Presentation Revision 1
18/26
Compressed Air Systems
-
8/8/2019 MBP Presentation Revision 1
19/26
U3E Refrigeration System
Cooling Water Hydronic Control Valve [PM]
Fluid: Compressed Air
Loss Rate 1.0m3/Hr Cost/Annum [1,000]
-
8/8/2019 MBP Presentation Revision 1
20/26
-
8/8/2019 MBP Presentation Revision 1
21/26
Manufacturing Wrapping Machinery
[Compressed AirLeaks]
-
8/8/2019 MBP Presentation Revision 1
22/26
Manufacturing Equipment Services
[Compressed AirLeaks]
-
8/8/2019 MBP Presentation Revision 1
23/26
Manufacturing Services [Steam Leaks]
-
8/8/2019 MBP Presentation Revision 1
24/26
Operational Cost Savings
35-40,000 PER ANNUM!!!
-