maxsg low voltage switchgear automation technology division wichita falls, texas 940-397-7000
DESCRIPTION
MaxSG Low Voltage Switchgear Automation Technology Division Wichita Falls, Texas 940-397-7000. Value Proposition. Our value proposition that we create for the customer is that we offer: Best of breed World-class, topnotch circuit breakers, switchgear, systems - PowerPoint PPT PresentationTRANSCRIPT
Insert image here
MaxSG Low Voltage SwitchgearAutomation Technology DivisionWichita Falls, Texas940-397-7000
Max
SG
Value Proposition
Our value proposition that we create for the customer is that weoffer: Best of breed World-class, topnotch circuit breakers, switchgear, systems
Engineered with highest safety, reliability and ease of operation We are highly customer-focused
Quick response to customer concerns Topnotch engineering support Accommodate customer change requests Pre-sale design advice Highest customer friendly service and support
Max
SG
LV Power Distribution
Max LINE A full line of low voltage power distribution equipment
Max
SG
StandardsSWITCHGEARANSI C37.20.1 -Metal Enclosed LV Power Circuit Breaker Switchgear
ANSI C37.51 -Testing of Metal Enclosed LV AC Power Circuit Breaker Switchgear
UL 1558 -Switchgear Assemblies
CIRCUIT BREAKERANSI C37.13 – LV AC Power Circuit Breakers Used in Equipment
ANSI C37.16 – Preferred Rating, Related Requirement, Application Recommendations For LV Power Circuit Breakers and AC Power Circuit Protectors
ANSI C37.50 – Testing of Low Voltage AC Power Circuit Breakers
UL 1066 – Low Voltage Power Circuit Breakers
Max
SG
BREAKERS
Max
SG
Breakers of Choice
Power (Air) Circuit Breaker
Max
SG
Emax
Air (Power) Circuit Breakers
800 - 5000 Amps
Fixed / Draw out
Electronic trip
Compact Size High Interrupting
Capability Extremely High Mechanical & Electrical life Manual / Electric Operation
Max
SG
Air (Power) Circuit Breakers - Emax
Five Frame Sizes E1 800 - 1200 Amps E2 800 – 1600 Amps E3 800 - 2500 Amps E4 3200 – 3600 Amps E6 4000 - 5000 Amps
Max
SG
PR121 Protection Features Only
PR122 Protection Features LCD Display Current Measurement Contact Wear Communications option
PR123 PR122 Features Harmonic Measurements Communications option
Air (Power) Circuit Breakers
Emax - Three Trip Unit Versions
Max
SG
Common set of accessories for all breaker frames. Control isolated from power poles. Install or change accessories and maintain UL listing. Pre-wired for quick connection.
Air (Power) Circuit Breakers
Emax Accessories
Max
SG
SWITCHGEAR
Max
SG
LV Switchgear MaxSG
Basic Specification
Operator Safety
Custom Applications Features with functions
Max
SG
LV Switchgear MaxSG - Specification
UL 1558 approved ANSI C37.20.1, C37.51 <=600 VAC 50/60Hz 800-5000 Amps Bus 42 kA to 125 kA Symmetrical Short
Circuit Rating Main-Tie-Main Transfer Schemes Indoor – Nema 1 Outdoor – N3R Non Walk-in & Walk-in Seismic Zone 4 Certified CSA Approved Mimic bus Communication
Max
SG
LV Switchgear MaxSG - Specification Cont.
Complete closed door breaker operation
Silver (Tin) plated bus Kirk Keys Transformer or bus duct
connections Overhead lifting device Breaker lift truck
Max
SG
LAYOUT
Max
SG
LV Switchgear MaxSG
Stack 4 feeder breakers in one section.
Install one feeder breaker below
and above main or tie breaker.
Max
SG
LV Switchgear MaxSG - Layout
Install main or ties in “C” compartment and one feeder breaker in “D”.
21” and 42” instrument
compartment
Max
SG
LV Switchgear MaxSG - Dimensions
E4 3600 Amp E3 2000 AmpE6 5000 Amp E4 3200 Amp E2 1600 AmpE6 4000 Amp E3 2500 Amp E2 800, 1200 Amp
1000 mm, 40” 800 mm, 32” 600 mm, 24”
Max
SG
LV Switchgear MaxSG
Standard Depth 1650 mm / 65” Optional 1900mm / 75”
Standard Height 2290 mm / 90”
Max
SG
NEMA 3R Outdoor•Non Walk-in
•Walk-in, with 36” isle in front of breaker
•Space heaters and thermostat
•Doors with latching mechanism to prevent inadvertent closing
•Fluorescent Lights & Receptacles
•Optional undercoating
Max
SG
CONSTRUCTION
Max
SG
Construction Structure:
12 ga steel rigid self supporting, expandable C-channel frame
Doors: Front doors - Semi-concealed hinges Rear doors – Bolted, optional hinge, Pad-locking handles
available Bus: Sized per ANSI/UL requirements,
Silver plated copper, Full length ground bus, 50 / 100% neutral available.
Max
SG
Structure
Door – Semi-concealed hinges from tampering
Standard bolted rear coverOptional – hinged rear door
Rear cable area
Paint – electro static powder coatANSI gray 61
Max
SG
Bus Design
•All bus rated for ANSI and ULStandard temperature riseMax 65ºC over 40ºC ambient
•Bare bus is standard •Insulated bus system is optional
•Adhesive coated tapes on connection joints•Flexible boots are optional
•Bus bracing using steel supported polyester type fingerplates
Max
SG
Features
•Silver plated bus - standard•Tin plated – optional
•Steel barriers provided as option for rear cable isolation
Max
SG
Customer Connections Control wire terminated at breaker cell
Reduces number of terminations Ample routing and termination areas
Inter-cubical wiring made easy Terminal strips Located in wire way on top of enclosure
Customer power connections made easy NEMA 2 hole pattern set at 45° angle for top
and bottom entry 1650mm / 65in standard depth (1900mm /
75in optional) provides large cable area.
Max
SG
User Safety Safety shutters are standard Pad locking accessories
Lock breaker in open position Lock breaker in test & disconnect position Lock shutters in closed position
Breakers and cells “keyed” Insulated bus available Barriers
Main Bus Compartment
Anti-insertion “key”
Max
SG
Instrument Compartment
Pilot lamps on breaker door
Control switch
Mimic Bus
Max
SG
Control Wiring
CT Mounting on BusControl circuit isolationCustomer terminal blockconnection
Front door grounding
Can offer customer Specified paint color
Max
SG
Breaker Compartment
Max
SG
Breaker – Draw Out Version CAPTION1. Trademark, size of CB2. Trip unit3. PB for manual opening4. PB for manual closing5. Lever to manually charge
closing spring6. Label with electrical
characteristics7. Mechanical device to signal
CB open “O” and Closed “I”8. Signal for springs charged
or discharged9. Mechanical indication of trip10. Key lock in open position11. Key lock and padlock in
racking-in, racking-out position12. Racking-in, racking-out device13. Terminal box14. Sliding contacts15. CB position indicator
Max
SG
Position Switch Contacts
• No T.O.C. contacts standard
• Optional 5 Truck Operated Contacts(2) Racked –in, (2) Racked-out, (1) Test Position
• Optional 10 Truck Operated Contacts(4) Racked –in, (4) Racked-out, (2) Test Position
Max
SG
Auxiliary Switch Contacts
• 4 Auxiliary contacts standard(2) N.O. and (2) N.C. , Plus (2) extra are dedicated to the trip unit
• Optional 10 Auxiliary contacts (5) N.O. and (5) N.C. , Plus (2) extra are dedicated to the trip unit (PR122/PR123 only)
• Optional 15 Auxiliary contacts Contacts are configurable and located outside the breaker
Max
SG
BREAKER COMPARTMENTPADLOCK DOOR (STANDARD)
PADLOCK DOOR LATCHABLE(OPTIONAL)
PADLOCK DEVICE FOR SAFETY SHUTTER
MECHANICAL LOCK FOR COMPARTMENT DOOR (OPTIONAL)
Max
SG
MECHANICAL INTERLOCKS
Max
SG
MECHANICAL INTERLOCKS - Optional
Horizontal Interlock
Vertical Interlock
Max
SG
MECHANICAL INTERLOCK OF BREAKERS
Max
SG
INSTRUMENTATION
Max
SG
LV Switchgear MaxSG
Breaker door mounted lights, meters and control Indicating lights Miniature volt and amp meter Miniature breaker control switch
Digital Multifunction Meters Power Measurement Meters GE PQM GE Multilin Family Square D Circuit Monitors Allen Bradley Meters Electro Industries Meters Shark 100
ABB Color Touchscreen CX Series
Max
SG
LV Switchgear MaxSG - Metering Customer metering for mid and advanced
applications Mid
Volts, Amps, Power, Energy, THD Communications RS-485 Modbus
Advanced Volts, Amps, Power Energy Harmonics Communications
Ethernet or Profibus DCS RS-485 Modbus I/O Revenue Class
Max
SG
Custom Metering/Communication
Provide GE PQM Power Quality Meter and Multilin product line for main-tie-main protection and/or generator protection.
Provide Power Measurement ION 6200, 7300, 7350, 7550, 7650,7700 and 8600 Energy Power Quality Meter with metering modbus configuration setup, and ABB Emax breakers all connected in modbus configuration.
Supply Power Logic series Circuit Monitors in modbus communication to customer for monitoring each breaker status.
Provide central display unit (CX series touch screens) to provide all the breakers trip unit data when they are all connected in modbus communication.
ABB TVSS Surge suppressors or customer specified TVSS. SD-Pocket is an application designed to connect Emax trip units to a PDA or
personal computer. SD-View 2000 and TestBus2.
Max
SG
COMMUNICATION DEVICES
Max
SG
LV Switchgear MaxSG
Breaker Communications Available as option with PR122, and
PR123 trip units Communicates
Metered values Breaker status Protection Parameters Number of Operations Last Event Contact Ware Pre Alarms
Modbus protocol Optional Bluetooth
Max
SG
Communication Systems – SD-View 2000
PC based software system
Max
SG
Communication Systems – SD-View 2000
SD-View 2000, PC-based software system enables communication•Send opening/closing commands to circuit-breakers •Read electrical installation values (current, voltage, power factor, etc.)•Read and modify trip characteristics of protection units•Log of history of installation•Status of apparatus•Abnormal operating situation•Current, voltage, power measurements in real time
Max
SG
Communication Devices - SD Pocket
SD-Pocket is an application designed to connect new protection releases to a PDA or PC
Enables use of wireless communication to: •Configure protection threshold function •Monitor measurement functions•Verify status of the circuit-breaker
SD-Pocket application scenarios include: •During start-up of switchgear, with rapid and error-free transfer of the protection parameters to the releases (also using the dedicated exchange file directly from Docwin); •During normal installation service, gathering information on the circuit-breaker and load conditions (last trip information, runtime currents, and other information)
Max
SG
Test Bus2
Diagnostic software for RS485 bus at startup service Troubleshoot entire modbus network for their
settings and addresses
Max
SG
Touch Screen – CX Series
Max
SG
Touch Screens Man Machine Interface Products
CX553 (5.7” Color TFT) CX553-1 (5.7" Color TFT) CX554-HB (5.7" Color High Contrast) CX554-3 (7.7" Color TFT) CX555 (10.4" Color TFT) Windows CE screen available
CX554-3 & above have printer portsTouch pads, Touch Monitors& Industrial PCs available
•Extended Modbus master Control up to 256 devices•Printer Ports & Ethernet •Available on certain models
Insert image here