max wiegand converter · 2021. 2. 1. · max wiegand converter residential / commercial application...

16
MAX.US.COM 01-26-21 _Rev 3.3 QUICK INSTALLATION GUIDE MAX WIEGAND CONVERTER RESIDENTIAL / COMMERCIAL APPLICATION Timers Diagnose Users Settings GATE STATUS: OPEN, OPENING, CLOSED CLOSE OPEN LAGUNA WOODS GATE GATE RELEASE Max Cloud App Max Wiegand Converter Max Operator Max Cell Hub

Upload: others

Post on 18-Mar-2021

10 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: MAX wiegand converter · 2021. 2. 1. · MAX WIEGAND CONVERTER RESIDENTIAL / COMMERCIAL APPLICATION sse GATE STATUS: OPEN, OP ENI G, CL S D CLOSE OPEN LAGUN AW ODS G TE GATE RELEASE

www.max.us.com

www.max.us.com

MAX.US.COM01-26-21 _Rev 3.3

QUICK INSTALLATION GUIDEMAX WIEGAND CONVERTER

RESIDENTIAL / COMMERCIAL APPLICATION

Timers Diagnose Users Settings

GATE STATUS: OPEN, OPENING, CLOSED

CLOSE

OPEN

LAGUNA WOODS GATE

GATE RELEASE

Max Cloud App

Max Wiegand Converter

MAX CELL HUB

POWER

COMMLINK

ONLINE

CELLLINK

RS485

5V(-) (+) GND

Max Operator

Max Cell Hub

Page 2: MAX wiegand converter · 2021. 2. 1. · MAX WIEGAND CONVERTER RESIDENTIAL / COMMERCIAL APPLICATION sse GATE STATUS: OPEN, OP ENI G, CL S D CLOSE OPEN LAGUN AW ODS G TE GATE RELEASE

2

www.max.us.com

www.max.us.com

TABLE OF CONTENT

Max Wiegand ConverterOverviewPedestrian Door Application Entry Gate ApplicationOverview Wireless Pedestrian Door Application - wirelessEntry Gate Application - wireless Testing and Pairing - wirelessProgram Wiegand Keycodes with time restrictions

3456891012

Page 3: MAX wiegand converter · 2021. 2. 1. · MAX WIEGAND CONVERTER RESIDENTIAL / COMMERCIAL APPLICATION sse GATE STATUS: OPEN, OP ENI G, CL S D CLOSE OPEN LAGUN AW ODS G TE GATE RELEASE

01-26-21 _Rev 3.3 3

www.max.us.com

www.max.us.com

Max Wiegand Converter

MAX WIEGAND CONVERTER OVERVIEW

WIEGAND PORT • To support 26-bit card readers, radio receivers & RFID transponders

• Program cards/keyfob, radio transmitters & transponder tags via Max Cloud App and assign optional time restrictions

• Track wiegand device activity in event log

RELAY PORT• Control access point with

dedicated relay

ACCESS PTRotary switch to

select access point #

REQUEST TO EXIT (RTE) PORT• Supports exit switch request

on pedestrian gates

RS-485 COMM PORT• To connect to Max Cell Hub

STATUS LEDs• Each port has indicator LEDs

for easy troubleshooting

POWER IN: 12 VDC / VAC

Max Wiegand Converter requires a Max Cell Hub. Both work exclusively with Max Gate Operators

Page 4: MAX wiegand converter · 2021. 2. 1. · MAX WIEGAND CONVERTER RESIDENTIAL / COMMERCIAL APPLICATION sse GATE STATUS: OPEN, OP ENI G, CL S D CLOSE OPEN LAGUN AW ODS G TE GATE RELEASE

4

www.max.us.com

www.max.us.com

01-21-21 _Rev 3.2 4

www.max.us.com

www.max.us.com

SOLENOID LOCK

Gnd

NO

Pow

er

GND

3

2

Wiring Solenoid Lock

Wiring Exit Push Button

Install Solenoid Lock as is shown

Install request to Exit Push Button as shown

NOCOM

(+)

(-)

PEDESTRIAN DOOR APPLICATIONUSING WIEGAND CONVERTER

PEDESTRIAN DOOR

MAX CELL HUB

MAX CELL HUB

POWER

COMMLINK

ONLINE

CELLLINK

RS485

5V(-) (+) GND

GND

MAX CELL HUB

POWER

COMMLINK

ONLINE

CELLLINK

RS485

5V(-)(+)GND

MAX CELL HUB

POWER

COMMLINK

ONLINE

CELLLINK

RS485

5V(-) (+) GND

D1

GND

GND

D0

Card Reader

4 Wiring Hub to Wiegand ConverterConnect RS-485 port of Max Cell Hub to RS-485 port of Max Wiegand Converter (+) to (+) (-) to (-) GND to GND

5

6

1

Wiring Power Input

Wiring Wiegand device

Connect 12VDC, 1A power transformer to Power Input port of Max Wiegand Converter(polarity does NOT matter)

Connect wiegand device as shown

GND+12V

Max Card Reader

Max Wiegand Converter

(+)

(+)

(-)

(-)

Select "Access PT#" using rotary switch

Select #0: to open gate via Cell Hub (note: wiegand relay NOT activated)

Select #1-9, A-E to trigger local relay on wiegand converterSelect #F: to open gate via Cell Hub (note: wiegand relay is also activated)

EXIT PUSH BUTTON

PRESS

to EXIT

RTEGND

Page 5: MAX wiegand converter · 2021. 2. 1. · MAX WIEGAND CONVERTER RESIDENTIAL / COMMERCIAL APPLICATION sse GATE STATUS: OPEN, OP ENI G, CL S D CLOSE OPEN LAGUN AW ODS G TE GATE RELEASE

12-21-20 _Rev 2.9 5

www.max.us.com

www.max.us.com

GND

MAX CELL HUB

POWER

COMMLINK

ONLINE

CELLLINK

RS485

5V(-)(+)GND

MAX CELL HUB

POWER

COMMLINK

ONLINE

CELLLINK

RS485

5V(-) (+) GND

Wiegand Receiver

+12V

GND

EXIT PUSH BUTTON

PRESS

to EXIT

Transponder

Transponder

OR

5 Wiring Power Input

Connect 12VDC, 1A power transformer to Power Input port of Max Keypad(polarity does NOT matter)

4 Wiring Wiegand device

Connect wiegand device as shown

3 Wiring Hub to Wiegand ConverterConnect RS-485 port of Max Cell Hub to RS-485 port of Max Wiegand Converter (+) to (+) (-) to (-) GND to GND

2 Wiring Exit Push Button

Install request to Exit Push Button as shown

MAX OPERATOR

MAX CELL HUB

POWER

COMMLINK

ONLINE

CELLLINK

RS485

5V(-) (+) GND

1 Select "Access PT#" using rotary switch

RTE

GND

GND

GND

ENTRY GATE APPLICATION USING WIEGAND CONVERTER

(+)

(+)

(-)

(-)

D1D0

Select #0: to open gate via Cell Hub (note: wiegand relay NOT activated)Select #1-9, A-E to trigger local relay on wiegand converterSelect #F: to open gate via Cell Hub (note: wiegand relay is also activated)

Page 6: MAX wiegand converter · 2021. 2. 1. · MAX WIEGAND CONVERTER RESIDENTIAL / COMMERCIAL APPLICATION sse GATE STATUS: OPEN, OP ENI G, CL S D CLOSE OPEN LAGUN AW ODS G TE GATE RELEASE

6

www.max.us.com

www.max.us.com

ACCESS PTRotary switch to

select access point #

RF CHANNELRotary switch to

select RF Channel #

WIRED-WIRELESS SWITCHAllow you to select wired or wireless connection

RANGE TEST SWITCHAllow you to test the signal strength between Master and Slave Units

PAIR BUTTONTo pair Slave to Master unit

REQUEST TO EXIT (RTE) PORT• Supports exit switch request

on pedestrian gates

STATUS LEDsEach port has indicator LEDs

for easy troubleshooting

WIRELESS MAX WIEGAND CONVERTER OVERVIEW

Select #0: to open gate via Cell Hub (note: wiegand relay

NOT activated)

Select #1-9, A-E to trigger local relay on wiegand

converterSelect #F: to open gate via

Cell Hub (note: wiegand relay is also activated)

RELAY PORT• Control access point with

dedicated relay

RS-485 COMM PORT• To connect to Max Cell Hub

POWER IN: 12 VDC / VAC

WIEGAND PORT • To support 26-bit card readers, radio receivers & RFID transponders• Program cards/keyfob, radio transmitters & transponder tags via Max Cloud App and assign optional time restrictions• Track wiegand device activity in event log

Wireless Max Wiegand Converter requires a Max Cell Hub. Both work exclusively with Max Gate Operators

Wireless Max Wiegand Converter

Page 7: MAX wiegand converter · 2021. 2. 1. · MAX WIEGAND CONVERTER RESIDENTIAL / COMMERCIAL APPLICATION sse GATE STATUS: OPEN, OP ENI G, CL S D CLOSE OPEN LAGUN AW ODS G TE GATE RELEASE

01-21-21 _Rev 3.2 7

www.max.us.com

www.max.us.com

Each facility need a unique ACCESS PT # and RF Channel #

WIRELESS MASTER - SLAVE CONNECTION OVERVIEW

Up to 1 mile range direct line off site

MAX CELL HUB

GND

MAX CELL HUB

POWER

COMMLINK

ONLINE

CELLLINK

RS485

5V(-)(+)GND

MAX CELL HUB

POWER

COMMLINK

ONLINE

CELLLINK

RS485

5V(-) (+) GND

GND

(+)

(+)

(-)

(-)

One master wireless Max Wiegand Converter can communicate with up to 15 slave units

Wireless Max Wiegand Converter

Wireless Max Wiegand Converter

Wireless Max Wiegand Converter

Wireless Max Wiegand Converter

Wireless Max Wiegand Converter

MASTER

SLAVE #1

SLAVE #4

SLAVE #2

SLAVE #3

Page 8: MAX wiegand converter · 2021. 2. 1. · MAX WIEGAND CONVERTER RESIDENTIAL / COMMERCIAL APPLICATION sse GATE STATUS: OPEN, OP ENI G, CL S D CLOSE OPEN LAGUN AW ODS G TE GATE RELEASE

ENTRY GATE APPLICATION USING WIRELESS MAX WIEGAND CONVERTER

ENTRY GATE APPLICATION USING WIRELESS MAX WIEGAND CONVERTER

8

www.max.us.com

www.max.us.com

8

4

6

Wire Wiegand device to Slave Wiegand Converter

Connect wiegand device as shown

Slide switch to WIREDon Master

Slide switch to WIRELESSon Slave

PEDESTRIAN DOORPEDESTRIAN DOOR APPLICATION

USING WIRELESS MAX WIEGAND CONVERTER

3 Wiring Hub to Master Wiegand Converter

Connect RS-485 port of Max Cell Hub to RS-485 port of Max Wiegand Con-verter (+) to (+) (-) to (-) GND to GND

Up to 1 mile range direct line of site

10

11

Install Selenoid Lock as shown

Install Push Button as shown

4

9

Wiring Power Input

Connect Power Input

Connect 12VDC, 1A power transformer to Power Input port of Max Wiegand Converter (polarity does NOT matter)

1 Select RF channel

5 Use same RF channel as Master Unit

2

7

Select "Access PT#" using rotary switch

Select "Access PT#" same as Master

Select #0: to open gate via Cell Hub (note: wiegand relay NOT activated)

Select #1-9, A-E to trigger local relay on wiegand converterSelect #F: to open gate via Cell Hub (note: wiegand relay is also activated)

MAX OPERATORMAX CELL HUB

MAX CELL HUB

POWER

COMMLINK

ONLINE

CELLLINK

RS485

5V(-) (+) GND

GND

MAX CELL HUB

POWER

COMMLINK

ONLINE

CELLLINK

RS485

5V(-)(+)GND

MAX CELL HUB

POWER

COMMLINK

ONLINE

CELLLINK

RS485

5V(-) (+) GND

GND

GND

D0

Card Reader

GND

GND

+12V

+12V

Wireless Max Wiegand Converter

Wireless Max Wiegand Converter

MASTER

SLAVE

(+)

(+)

(-)

(-)

RTE

GND

PRESS

to EXIT

NOCO

M

Gnd

NO

Pow

er

(+)

(-) GND

SOLENOID LOCK

D1

Page 9: MAX wiegand converter · 2021. 2. 1. · MAX WIEGAND CONVERTER RESIDENTIAL / COMMERCIAL APPLICATION sse GATE STATUS: OPEN, OP ENI G, CL S D CLOSE OPEN LAGUN AW ODS G TE GATE RELEASE

12-21-20 _Rev 2.9 9

Slide switch to WIREDon Master

Transponder

www.max.us.com

www.max.us.com

ENTRY GATE APPLICATION USING WIRELESS MAX WIEGAND CONVERTER

ENTRY GATE APPLICATION USING WIRELESS MAX WIEGAND CONVERTER

3 Wiring Hub to Master Wiegand Converter

Connect RS-485 port of Max Cell Hub to RS-485 port of Max Wiegand Con-verter (+) to (+) (-) to (-) GND to GND

9

5

7

Wire Wiegand device to Slave Wiegand Converter

Connect wiegand device as shown

Up to 1 mile range direct line of site

MAX CELL HUB

MAX CELL HUB

POWER

COMMLINK

ONLINE

CELLLINK

RS485

5V(-) (+) GND

GND

MAX CELL HUB

POWER

COMMLINK

ONLINE

CELLLINK

RS485

5V(-)(+)GND

MAX CELL HUB

POWER

COMMLINK

ONLINE

CELLLINK

RS485

5V(-) (+) GND

D1GN

D

GND

D0

GND

GND

+12V

+12V

Wireless Max Wiegand Converter

Wireless Max Wiegand Converter

(+)

(+)

(-)

(-)

Wiegand Receiver

Transponder

OR

4

10

Wiring Power Input

Connect Power Input

Connect 12VDC, 1A power transformer to Power Input port of Max Wiegand Converter(polarity does NOT matter)

Slide switch to WIRELESS on Slave

1 Select RF channel

6 Use same RF channel as Master Unit

2Select "Access PT#" using rotary switch

Select #0: to open gate via Cell Hub (note: wiegand relay NOT activated)

Select #1-9, A-E to trigger local relay on wiegand converterSelect #F: to open gate via Cell Hub (note: wiegand relay is also activated)

8 Select "Access PT#" same as Master

SLAVE

MASTER

Page 10: MAX wiegand converter · 2021. 2. 1. · MAX WIEGAND CONVERTER RESIDENTIAL / COMMERCIAL APPLICATION sse GATE STATUS: OPEN, OP ENI G, CL S D CLOSE OPEN LAGUN AW ODS G TE GATE RELEASE

10

www.max.us.com

www.max.us.com

To obtain optimum wireless communication, install wiegand wireless units min. 10ft above ground and ensure their antennas are not near metal surfaces.

RANGE TESTING AND PAIRING USING WIRELESS MAX WIEGAND CONVERTERS

3 Slide switch to WIREDon Master

1 Select RF channel

Turn ON Range Test Switch

Up to 1 mile range direct line off site

MAX CELL HUB

MAX CELL HUB

POWER

COMMLINK

ONLINE

CELLLINK

RS485

5V(-) (+) GND

GND

MAX CELL HUB

POWER

COMMLINK

ONLINE

CELLLINK

RS485

5V(-)(+)GND

MAX CELL HUB

POWER

COMMLINK

ONLINE

CELLLINK

RS485

5V(-) (+) GND

GND

(+)

(+)

(-)

(-)

Wireless Max Wiegand Converter

MASTER

2 Select "Access PT#" using rotary switch

LED signal lights will start flashing sequentially. Go to the Slave unit to verify and complete test.

4

Page 11: MAX wiegand converter · 2021. 2. 1. · MAX WIEGAND CONVERTER RESIDENTIAL / COMMERCIAL APPLICATION sse GATE STATUS: OPEN, OP ENI G, CL S D CLOSE OPEN LAGUN AW ODS G TE GATE RELEASE

01-26-21 _Rev 3.3 11

www.max.us.com

www.max.us.com

RANGE TESTING AND PAIRING USING WIRELESS MAX WIEGAND CONVERTERS

7 Slide switch to WIRELESSon Slave

5 Use same RF channel as Master Unit

Wireless Max Wiegand Converter

SLAVE

To erase all paired slave units, PRESS and HOLD the pair button on Master for at least 5 seconds, until the pair LED starts blinking, then let go of the pair button.The LED will blink three times once the erase is completed.

6 Use same PT# as Master Unit

Repeat above steps for each additional SLAVE wireless unitsAfter all slave units are paired

TURN OFF RANGE TEST ON MASTER WIRELESS UNIT

The pair LED will come ON as on confirmation.

Once Master and Slave unitare paired, turn OFF range test switch on slave.

9

10

After few seconds, all three LED's will TURN ON when RF range is ok. If range is poor, (less than 3 LED's on) reposition Master or Slave unit to get better range.

8 Turn ON Range Test Switch

Press the Pair Switch shortly

Turn OFF Range Test Swicth

Page 12: MAX wiegand converter · 2021. 2. 1. · MAX WIEGAND CONVERTER RESIDENTIAL / COMMERCIAL APPLICATION sse GATE STATUS: OPEN, OP ENI G, CL S D CLOSE OPEN LAGUN AW ODS G TE GATE RELEASE

12

www.max.us.com

www.max.us.com

1

2

3

4

Press Users icon in the main menu

Then Press Add a User in the following menu

Enter Name of your visitor

Program Wiegand Keycode

Enter Facility and Wiegand Keycode for the transmitter, keyfob or tag

User Name

PROGRAM WIEGAND KEYCODES WITH RESTRICTIVE TIME ZONES

Rose

Facility Wiegand Keycode

123 12345

Page 13: MAX wiegand converter · 2021. 2. 1. · MAX WIEGAND CONVERTER RESIDENTIAL / COMMERCIAL APPLICATION sse GATE STATUS: OPEN, OP ENI G, CL S D CLOSE OPEN LAGUN AW ODS G TE GATE RELEASE

01-26-21 _Rev 3.3 13

www.max.us.com

www.max.us.com

PROGRAM WIEGAND KEYCODES WITH RESTRICTIVE TIME ZONES

5 Assign a timer for wiegand keycode (OPTIONAL)

If you choose No Timerwiegand Keycode has no time restriction

Choose one of six timer schedules

Watch video tutorials from Max Cloud App, just go to the home screen

Watch video tutorials from Max Cloud App, just go to the home screen

Applying restrictive time period to keycodes improves the security to your gate site

6 Press the back button [<] on the top left of the screen to confirm creating a user

Timer

ORSCAN CODEto watch tutorial

Page 14: MAX wiegand converter · 2021. 2. 1. · MAX WIEGAND CONVERTER RESIDENTIAL / COMMERCIAL APPLICATION sse GATE STATUS: OPEN, OP ENI G, CL S D CLOSE OPEN LAGUN AW ODS G TE GATE RELEASE

14

www.max.us.com

www.max.us.com

CARD READER

Max Wiegand Converter Max Wiegand Converter Max Wiegand ConverterRS485 COMM LINK

Access Point # 1Access Point # 2Access Point # 3

Max Cell Hub

RADIORECEIVER

RFID Transponder

• Wiegand Keycodes with optional time zone restrictions• Keypad Keycodes with optional time zone restrictions• Virtual Transmitters (App Users) with optional time restrictions • Guest Passes with date and time restrictions• Auto Open / Close Timer to set daily recurring schedule for gate operator• Text Alerts on App for gate status, gate tamper and sensor fail events• EVENT LOG to track gate site events on App. Events tracked includes:

- Max Cloud App OPEN commands - Guest Pass OPEN commands - Keypad keycode entries - Wiegand keycodes scans - All programming changes

• ERROR LOG to monitor and diagnose gate operator issues remotely

MAX CELL HUB

POWER

COMMLINK

ONLINE

CELLLINK

RS485

5V(-) (+) GND

Max Hub can support up to 16 access points using Max Keypads and/or Max Wiegand Converter Units

INTEGRATED ACCESS CONTROLINTEGRATED ACCESS CONTROL

Timers Diagnose Users Settings

GATE STATUS: OPEN, OPENING, CLOSED

CLOSE

OPEN

LAGUNA WOODS GATE

GATE RELEASE

MAX WIEGAND CONVERTERS

Page 15: MAX wiegand converter · 2021. 2. 1. · MAX WIEGAND CONVERTER RESIDENTIAL / COMMERCIAL APPLICATION sse GATE STATUS: OPEN, OP ENI G, CL S D CLOSE OPEN LAGUN AW ODS G TE GATE RELEASE

01-26-21 _Rev 3.3 15

www.max.us.com

www.max.us.com

CARD READER

WirelessMax Wiegand Converter

WirelessMax Wiegand Converter

WirelessMax Wiegand Converter

RS485 COMM LINK

Max Cell Hub

RADIORECEIVER

RFID Transponder

• Wiegand Keycodes with optional time zone restrictions• Keypad Keycodes with optional time zone restrictions• Virtual Transmitters (App Users) with optional time restrictions • Guest Passes with date and time restrictions• Auto Open / Close Timer to set daily recurring schedule for gate operator• Text Alerts on App for gate status, gate tamper and sensor fail events• EVENT LOG to track gate site events on App. Events tracked includes:

- Max Cloud App OPEN commands - Guest Pass OPEN commands - Keypad keycode entries - Wiegand keycodes scans - All programming changes

• ERROR LOG to monitor and diagnose gate operator issues remotely

MAX CELL HUB

POWER

COMMLINK

ONLINE

CELLLINK

RS485

5V(-) (+) GND

Max Hub can support up to 16 access points using Max Keypads and/or Wireless Max Wiegand Converter Units

INTEGRATED ACCESS CONTROLINTEGRATED ACCESS CONTROL

Timers Diagnose Users Settings

GATE STATUS: OPEN, OPENING, CLOSED

CLOSE

OPEN

LAGUNA WOODS GATE

GATE RELEASE

WIRELESS MAX WIEGAND CONVERTERS

MASTERMASTER

SLAVE #2

SLAVE #1

Page 16: MAX wiegand converter · 2021. 2. 1. · MAX WIEGAND CONVERTER RESIDENTIAL / COMMERCIAL APPLICATION sse GATE STATUS: OPEN, OP ENI G, CL S D CLOSE OPEN LAGUN AW ODS G TE GATE RELEASE

QUICK INSTALLATION GUIDEMAX WIEGAND CONVERTER

RESIDENTIAL / COMMERCIAL APPLICATION

Timers Diagnose Users Settings

GATE STATUS: OPEN, OPENING, CLOSED

CLOSE

OPEN

LAGUNA WOODS GATE

GATE RELEASE

Max Cloud App

Max Wiegand Converter

MAX CELL HUB

POWER

COMMLINK

ONLINE

CELLLINK

RS485

5V(-) (+) GND

Max Operator

Max Cell Hub

www.max.us.com

www.max.us.com

10530 Lawson River Ave., Fountain Valley, CA 92708(949) 699-0220 | [email protected] | MAX.US.COM