masonry arch bridge assessment - bridgeforum · 4. a masonry arch is a statically indeterminate...

42
Masonry Arch Bridge Assessment Prof. Matthew Gilbert University of Sheffield Bridge Owners’ Forum 17 th April 2017

Upload: others

Post on 15-May-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Masonry Arch Bridge Assessment - BridgeForum · 4. A masonry arch is a statically indeterminate structure. This means that in an uncracked arch there are many possible load paths,

Masonry Arch Bridge Assessment

Prof. Matthew Gilbert University of Sheffield

Bridge Owners’ Forum17th April 2017

Page 2: Masonry Arch Bridge Assessment - BridgeForum · 4. A masonry arch is a statically indeterminate structure. This means that in an uncracked arch there are many possible load paths,

Contents

• Background & supporting research

• Development of assessment guidance

• Next steps

• Conclusions

Page 3: Masonry Arch Bridge Assessment - BridgeForum · 4. A masonry arch is a statically indeterminate structure. This means that in an uncracked arch there are many possible load paths,

Background & supporting research

Page 4: Masonry Arch Bridge Assessment - BridgeForum · 4. A masonry arch is a statically indeterminate structure. This means that in an uncracked arch there are many possible load paths,

Vital infrastructure

• Approx. 70,000 spans in UK (1M worldwide)

• Almost all >100 years old

• Need regular assessment

Page 5: Masonry Arch Bridge Assessment - BridgeForum · 4. A masonry arch is a statically indeterminate structure. This means that in an uncracked arch there are many possible load paths,

But…

• Current assessment codes (e.g. BD21) don’t take account of research of last few decades

• Also, ‘SLS’ and ‘ULS’ considerations are usually combined (e.g. ‘SLS’ deemed satisfied if working load ≤ 0.5’ULS’ load)

• Over-conservative for bridges where real ‘SLS’ load and ‘ULS’ load are close together

• Under-conservative for bridges where real ‘SLS’ load and ‘ULS’ load are far apart

Page 6: Masonry Arch Bridge Assessment - BridgeForum · 4. A masonry arch is a statically indeterminate structure. This means that in an uncracked arch there are many possible load paths,

1/17/2017 © The University of Sheffield

6

A tale of two bridges…

0

75

150

225

300

0 10 20 30 40 50 60 70 80 90

Deflection (mm)

Un

co

rre

cte

d l

oa

d (

kN

)

Arch 06

Arch 02

Abutment

secured

Page 7: Masonry Arch Bridge Assessment - BridgeForum · 4. A masonry arch is a statically indeterminate structure. This means that in an uncracked arch there are many possible load paths,

Therefore:

• Need a better holistic understanding of arch-bridges at ultimate and working load states

Page 8: Masonry Arch Bridge Assessment - BridgeForum · 4. A masonry arch is a statically indeterminate structure. This means that in an uncracked arch there are many possible load paths,

Therefore:

• Need a better holistic understanding of arch-bridges at ultimate and working load states

• To help achieve this, an EPSRC research project, has recently been undertaken:

• Focus has been on soil-filled bridges, with 3 strands:

1. Experiments 2. Modelling 3. Guidance

Page 9: Masonry Arch Bridge Assessment - BridgeForum · 4. A masonry arch is a statically indeterminate structure. This means that in an uncracked arch there are many possible load paths,

The effect of soil backfill

0

100

200

300

400

500

600

700

0 2 4 6 8 10

displacement (mm)

Lo

ad

(kN

)

Backfilled

No backfill

10x

Page 10: Masonry Arch Bridge Assessment - BridgeForum · 4. A masonry arch is a statically indeterminate structure. This means that in an uncracked arch there are many possible load paths,

The effect of soil backfill (2)

(i) Self-weight;

(ii) Dispersal of live load;

(iii) Passive restraint.

AD

C

BDispersal Passive restraint

Page 11: Masonry Arch Bridge Assessment - BridgeForum · 4. A masonry arch is a statically indeterminate structure. This means that in an uncracked arch there are many possible load paths,

What about working loads?

• Repeated (cyclic) loads can lead to degradation of the bridge

• ‘Permissible limit state’ (PLS) = the state beyond which long term load induced degradation occurs

Page 12: Masonry Arch Bridge Assessment - BridgeForum · 4. A masonry arch is a statically indeterminate structure. This means that in an uncracked arch there are many possible load paths,

Experimental

• New ‘medium scale’ rig

• Automated filling and testing

• Benefits: rapid turnaround and high quality data

WP3: Assessment

Page 13: Masonry Arch Bridge Assessment - BridgeForum · 4. A masonry arch is a statically indeterminate structure. This means that in an uncracked arch there are many possible load paths,

Experimental [2]

• Existing ‘large scale’ rig upgraded to allow cyclic and railway loads to be applied

• Benefits: 3m spans are representative of many bridges in the field

Page 14: Masonry Arch Bridge Assessment - BridgeForum · 4. A masonry arch is a statically indeterminate structure. This means that in an uncracked arch there are many possible load paths,

Sample test results

17/01/2017 © The University of Sheffield

13

Test* Description

ULS1 Benchmark (pseudo-static)

ULS2 Retest (pseudo-static)

ULS3 Retest (pseudo-static)

‘Cyclic ULS’ Progressively increasing cyclic loading intensity

*cyclic loading (min 100,000 cycles) applied prior to each ULS test, helping to compact fill and help restore original arch profile

Page 15: Masonry Arch Bridge Assessment - BridgeForum · 4. A masonry arch is a statically indeterminate structure. This means that in an uncracked arch there are many possible load paths,

ULS1

ULS2

ULS3

Page 16: Masonry Arch Bridge Assessment - BridgeForum · 4. A masonry arch is a statically indeterminate structure. This means that in an uncracked arch there are many possible load paths,

84kN: falling brick disturbs

displacement gauges

90kN: row of bricks falls, reducing load

sustainable to 72kN

Page 17: Masonry Arch Bridge Assessment - BridgeForum · 4. A masonry arch is a statically indeterminate structure. This means that in an uncracked arch there are many possible load paths,
Page 18: Masonry Arch Bridge Assessment - BridgeForum · 4. A masonry arch is a statically indeterminate structure. This means that in an uncracked arch there are many possible load paths,
Page 19: Masonry Arch Bridge Assessment - BridgeForum · 4. A masonry arch is a statically indeterminate structure. This means that in an uncracked arch there are many possible load paths,

Numerical modelling

Various modelling approaches:

1. ‘Crude’: ignores most of the anticipated effects of soil

2. ‘Simplified’: includes the anticipated effects of soil

3. ‘Midrange’: models soil directly (basic material model)

4. ‘Complex’: models soil directly (detailed material model etc)

Page 20: Masonry Arch Bridge Assessment - BridgeForum · 4. A masonry arch is a statically indeterminate structure. This means that in an uncracked arch there are many possible load paths,

‘Simplified’ example

• ‘Rigid block’ limit analysis method (e.g. used by LimitState:RING) models anticipated effects of soil

Page 21: Masonry Arch Bridge Assessment - BridgeForum · 4. A masonry arch is a statically indeterminate structure. This means that in an uncracked arch there are many possible load paths,

‘Midrange’ example

• Discontinuity Layout Optimization (DLO) extends ‘rigid block’ method to allow masonry and soil to be modelled [e.g. see Smith & Gilbert, Proc. Roy. Soc. A, 2007; software: www.limitstate.com/geo]

Page 22: Masonry Arch Bridge Assessment - BridgeForum · 4. A masonry arch is a statically indeterminate structure. This means that in an uncracked arch there are many possible load paths,

‘Midrange’ example

• Discontinuity Layout Optimization (DLO) extends ‘rigid block’ method to allow masonry and soil to be modelled [e.g. see Smith & Gilbert, Proc. Roy. Soc. A, 2007; software: www.limitstate.com/geo]

• Steps in DLO procedure:

Page 23: Masonry Arch Bridge Assessment - BridgeForum · 4. A masonry arch is a statically indeterminate structure. This means that in an uncracked arch there are many possible load paths,

Validation: small-scale bridges• Good agreement (±10%) if mobilized strength used in

passive region [see: Callaway, Gilbert & Smith, Proc. ICE, 2012]

t=tanf

t=0.33tanf

Page 24: Masonry Arch Bridge Assessment - BridgeForum · 4. A masonry arch is a statically indeterminate structure. This means that in an uncracked arch there are many possible load paths,

Validation: large-scale bridges

Page 25: Masonry Arch Bridge Assessment - BridgeForum · 4. A masonry arch is a statically indeterminate structure. This means that in an uncracked arch there are many possible load paths,

Aside: ‘physics engine’ model

23

Page 26: Masonry Arch Bridge Assessment - BridgeForum · 4. A masonry arch is a statically indeterminate structure. This means that in an uncracked arch there are many possible load paths,

Key project findings

• Below a certain load level (e.g. 50kN), repeated cyclic loads can be applied with seemingly no limit

• At higher levels of load repeated cyclic loads will curtail the life of a bridge

• The trigger point appears to be the point at which horizontal soil pressures start to need to be mobilized, to restrain the barrel

24

Page 27: Masonry Arch Bridge Assessment - BridgeForum · 4. A masonry arch is a statically indeterminate structure. This means that in an uncracked arch there are many possible load paths,

Development of assessment guidance

Page 28: Masonry Arch Bridge Assessment - BridgeForum · 4. A masonry arch is a statically indeterminate structure. This means that in an uncracked arch there are many possible load paths,

Assessment guidance

• Guidance document currently being drafted

• Sample areas covered:

• Fundamental arch bridge behaviour

• A critique of multi-level assessment

• Observational & analysis-based assessment

• Ultimate and Permissible Limit State analysis

26

Page 29: Masonry Arch Bridge Assessment - BridgeForum · 4. A masonry arch is a statically indeterminate structure. This means that in an uncracked arch there are many possible load paths,

Contents listSummary

Acknowledgements

Glossary of Terms

1 Introduction

2 Management of Masonry Arch Bridges

3 Bridge Construction and Behaviour

4 Preparing for an Assessment

5 Analysis Methods

6 Monitoring Methods

7 Undertaking an Assessment

Appendices

References

27

Page 30: Masonry Arch Bridge Assessment - BridgeForum · 4. A masonry arch is a statically indeterminate structure. This means that in an uncracked arch there are many possible load paths,

Level 1: [e.g. MEXE]

Level 2: [e.g. rigid block analysis]

Level 3: [e.g. finite, discrete element]

• more complex

• more input parameters

• more expertise required

• should be more accurate (and less conservative)

Multi-level assessment: are current tools compatible with this?

Page 31: Masonry Arch Bridge Assessment - BridgeForum · 4. A masonry arch is a statically indeterminate structure. This means that in an uncracked arch there are many possible load paths,

Aside: the MEXE method

• Semi-empirical method dating from the 1940s, and still in use

• The method was reviewed a few years ago:

• Pippard’s simplified equations (on which MEXE is based) are non-conservative when short span bridges are involved[See: Wang & Melbourne, Proc. ICE, 2010]

• Other issues:

• ‘Black box’ method (engineer left unenlightened…)

• Difficult to improve in the light of research

Page 32: Masonry Arch Bridge Assessment - BridgeForum · 4. A masonry arch is a statically indeterminate structure. This means that in an uncracked arch there are many possible load paths,

Example contents (Table 9)

30

Observation Note

1. The pattern of loading in relation to the shape of a masonry gravity structure governs stability.

This means that it is important to measure the shape of the arch barrel, piers etc. when undertaking an assessment, and to use loadings which are representative of those that will be applied in practice.

2. Masonry gravity structures resist applied actions through their inherent self-weight and thickness.

Since self-weight is normally beneficial it should be factored down (as well as up) for the purposes of assessment. Also the thickness of masonry elements should be carefully measured prior to an assessment.

3. The load carrying capacity of a masonry arch bridge reduces during a flood event.

If the bridge is flooded up to traffic surface level then buoyant self-weights should be used in any assessment calculations. As buoyant self-weight is much lower than dry self-weight then the load carrying capacity is reduced (see 2. above).

4. A masonry arch is a statically indeterminate structure.

This means that in an uncracked arch there are many possible load paths, so that it is not possible to be certain which areas are highly stressed and which are not.

5. Stresses scale linearly with bridge size. This means that in a long span bridge stresses will often be high in comparison to foreseeable material strength.

6. The load carrying capacity of a long span bridge with a multi-ring brickwork arch barrel will be significantly lower than that of an equivalent bridge with a bonded or single-ring voussoir arch barrel.

Because of 5. above it is highly likely that the rings will separate and prevent the load carrying capacity associated with a voussoir arch bridge from being attained.

7. Soil fill material (if present) provides vertical loading which pre-stresses the arch barrel, enhancing resistance. It also distributes axle loads and provides lateral restraint to the arch barrel.

This means that the load carrying capacity of a soil-filled masonry arch will typically be an order of magnitude greater than that of a bare arch vault. An arch with a large depth of soil fill relative to its span is unlikely to be significantly affected by live loads.

8. In a very long span bridge vehicle loads are small in relation to the self-weight of the structure.

Conversely, vehicle loads are high in relation to the self-weight of a short span structure.

9. Stiff elements attract high stresses. This has a wide range of consequences; e.g. repointing with strong/stiff cement mortar a bridge constructed originally with lime mortar is not likely to be worthwhile as the cement mortar will attract high stresses and will fail prematurely.

Page 33: Masonry Arch Bridge Assessment - BridgeForum · 4. A masonry arch is a statically indeterminate structure. This means that in an uncracked arch there are many possible load paths,

Overarching methodology

• Move away from BD21/BA16 approach (& factors); instead use Eurocode factors where possible

• For assessment based on analysis, recommend both ULS and service load checks are carried out

31

Page 34: Masonry Arch Bridge Assessment - BridgeForum · 4. A masonry arch is a statically indeterminate structure. This means that in an uncracked arch there are many possible load paths,

Permissible limit state (PLS)

• PLS = the state beyond which long term load induced degradation occurs

• Very useful for bridge management purposes, but:

• No clear link between the ULS and the PLS

• Hence need to establish the PLS directly

32

Page 35: Masonry Arch Bridge Assessment - BridgeForum · 4. A masonry arch is a statically indeterminate structure. This means that in an uncracked arch there are many possible load paths,

Key PLS trigger

Excessive system level deformation

• Largely rigid body masonry movements due to ‘lack of fit’ and/or reliance on passive soil restraint

• Leads to ratcheting (distortion of profile) and/or degradation of masonry due to opening & closing of joints

33

Page 36: Masonry Arch Bridge Assessment - BridgeForum · 4. A masonry arch is a statically indeterminate structure. This means that in an uncracked arch there are many possible load paths,

PLS analysis - example

• Neglect passive restraint in PLS analysis (as requires large structural deformations to generate)

• Also use ‘degraded’ masonry mechanical properties

Page 37: Masonry Arch Bridge Assessment - BridgeForum · 4. A masonry arch is a statically indeterminate structure. This means that in an uncracked arch there are many possible load paths,

PLS vs. ULS (strong fill)

PLS vs. ULS (weak fill)

PLS with finite crack at crown

Page 38: Masonry Arch Bridge Assessment - BridgeForum · 4. A masonry arch is a statically indeterminate structure. This means that in an uncracked arch there are many possible load paths,

Next steps

Page 39: Masonry Arch Bridge Assessment - BridgeForum · 4. A masonry arch is a statically indeterminate structure. This means that in an uncracked arch there are many possible load paths,

Next steps

• Working hard to complete a full draft of guidance document (for comment)

• Planned future research:

• Investigate behaviour of cracked arches under cyclic loads, and apparent ‘self-healing’ behaviour

• Develop better understanding of 3D behaviour

• More robust multi-level assessment methodology

Page 40: Masonry Arch Bridge Assessment - BridgeForum · 4. A masonry arch is a statically indeterminate structure. This means that in an uncracked arch there are many possible load paths,

Conclusions

Page 41: Masonry Arch Bridge Assessment - BridgeForum · 4. A masonry arch is a statically indeterminate structure. This means that in an uncracked arch there are many possible load paths,

Conclusions

• EPSRC funded research project has provided valuable new data

• Assessment guidance arising from the project is currently being drafted

• However, despite considerable research over the last few decades, still unanswered questions

Page 42: Masonry Arch Bridge Assessment - BridgeForum · 4. A masonry arch is a statically indeterminate structure. This means that in an uncracked arch there are many possible load paths,

Acknowledgements

• Other investigators: Prof. Clive Melbourne, Dr Colin Smith, Dr Gareth Swift, Prof. Robert Harrison

• Researchers: Michal Pytlos, Dr Sam Hawksbee, Dr Levingshan Augusthus Nelson, Hamid Safeer, Dr MaximeGueguin

• Steering Committee: Graham Cole, Dermot Kelly, Dr David Morris, Clive Woodruff, David Castlo, Zoltan Orban, Prof. Peter Walker, Dr Adrienn Tomor

• Sponsors: EPSRC, Network Rail, ADEPT, Balfour Beatty Rail, UIC