maroone honda of hollywood hodgen construction
TRANSCRIPT
441 (STATE ROAD 7 )
SH
ER
IDA
N S
TR
EE
T
G:\HODGEN\2010\F100121-FUTURE HOLLYWOOD HONDA\EXHIBIT\AERIAL OVERLAY EXHIBIT----->LAYOUT: LAYOUT1
SHEET TITLE:
SHEET NUMBER:
PROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
SCALE:
CAD I.D.:
REVISIONS:
PROJECT:
FOR
AERIAL OVERLAY EXHIBIT
AS NOTED
LA
ND
SCA
PE A
RC
HIT
EC
TS
EN
VIR
ON
ME
NT
AL
CO
NSU
LT
AN
TS
CIV
IL &
CO
NSU
LT
ING
EN
GIN
EE
RS
SUR
VE
YO
RS
PRO
JEC
T M
AN
AG
ER
ST
OW
SO
N, M
D
BO
WIE
, M
D
PU
RC
HA
SE
, N
Y
ALB
AN
Y, N
Y
SO
UT
HB
OR
OU
GH
, M
A
OF
FIC
ES
:
CO
RP
OR
AT
E O
FF
IC
E:
WA
RR
EN
, NJ
ST
ER
LIN
G, V
A
RO
NK
ON
KO
MA
, N
Y
CH
ALF
ON
T, P
A
WA
RR
EN
TO
N, V
A
CE
NT
ER
V
ALLE
Y, P
A
FO
RT
L
AU
DE
RD
ALE
, F
L
TA
MP
A, F
L
MAROONEHONDA OF
HOLLYWOOD
HODGENCONSTRUCTION
CITY OF HOLLYWOOD
BROWARD COUNTY, FLORIDA
F100121
CAD
JMG
. .
.
.
.
. .
.
.
.
. .
.
.
.
. .
.
.
.
. .
.
.
.
. .
.
.
.
. .
.
.
.
. .
.
.
.
. .
.
.
.
. .
.
.
.
. .
.
.
.
. .
.
.
.
1000 CORPORATE DRIVE, SUITE 250
FORT LAUDERDALE, FL 33334
PH: (954) 202-7000
FX: (954) 202-7070
www.BohlerEngineering.com
RADICE III
PROFESSIONAL ENGINEER
FLORIDA LICENSE No. 58629
January 3, 2012
1"= 50'
0 5012.52550
EX-1
AERIAL EXHIBIT
EX-1
AERIAL EXHIBIT
Hollywood, Florida Submittal Set 04.11.2013
YSM Design, P.C.1400 Dutch Valley PlSuite 1175Atlanta, GA 30324404-249-4555404-249-0770 fax
Miguel Yelos San [email protected]
Contact:Byung [email protected]
Architects
Nannis & Assoc. INC.5608 Battle Ridge Dr.Flowery Branch, GA 30542
Structural Engineer:
Walid A. Nannis, P.E., F.ASCEPH: 770.614.6114FAX:[email protected]
MEP Engineer MEHA, Engineering Inc.2837 Peterson PlaceNorcross GA 30071770-441-0019770-447-6918 fax
David Lu, P.E.Florida State License # 65228
David Lu - Project [email protected]
SHEET INDEXA001A100A201aA201bA202A251aA251bA252A401A501aA501bA502
COVER, EXTERIOR RENDERINGPROPOSED OVERALL FIRST FLOOR, STREET PROFILE, GENERAL SCOPE
PROPOSED SHOWROOM & PARTS PLANPROPOSED SERVICE DRIVE, NVD, AND SECOND FLOOR
SERVICE PLANSHOWROOM FINISH FLOOR
PROPOSED SERVICE DRIVE, NVD, SECOND FLOOR FINISH FLOORSERVICE FINISH FLOOR PLAN
MATERIAL LEGENDEXTERIOR ELEVATIONS IEXTERIOR ELEVATIONS II
SERVICE ELEVATIONS
Sheet Number:
Project Number:Drawn By:Checked By:Approved By:
Sheet Title:
Project:
Client:
Copyright (c) 2012 YSM Design, P.C.
All reports, plans, specifications, computer files, field data, notes and otherdocuments and instruments prepared by YSM Design, P.C. shall retain allcommon law, statutory and other reserved rights, including copyrightthereto.
This drawing may not be reproduced in whole or in part without writtenpermission of YSM Design. It is to be returned upon request. Scales asstated are only valid on the original drawings.
Signed & Sealed:
1320 Ellsworth Industrial BlvdSuite A-100Atlanta GA 30318404-249-4555 tel404-355-6394 fax
www.ysmdesign.com
AUTOMOTIVERETAIL ARCHITECTURE
4/9/
2013
7:2
8:32
PM
A001
Cover, ProjectDirectory
11050EGBYBY
MarooneHondaHollywood
Autonation Inc.
200 SW 1st Avenue 14th FloorFort Lauderdale, FL 33301
2400 North 60th AveHollywood, Broward County, FL
ABBREVIATIONS@ ATA.B. ANCHOR BOLTACMU ARCHITECTURAL MASONRY UNITADJ ADJACENTA.F.F. ABOVE FINISH FLOORAIA AM INST OF ARCHITECTSAISC AM INST OF STEEL CONSTRUCTIONALT. ALTERNATEALUM. ALUMINUMARCH. ARCHITECTASTM AM SOC OF TESTING & MATERIALSBLKG. BLOCKINGC.I.P. CAST IN PLACECAB CABINETCJ CONTROL JOINTCLG CEILINGCMU CONCRETE MASONRY UNITCOL. COLUMNCONC. CONCRETECONT. CONTINUOUSC.O. CLEAN OUTCSI CONST. SPECIFICATIONS INSTITUTEDBL. DOUBLEDIA. DIAMETERDIAG. DIAGONALDWG DRAWINGDS DOWNSPOUTELEC. ELECTRICALEQ. EQUALEQUIP. EQUIPMENTEJ EXPANSION JOINTEXT. EXTERIORF.O. FACE OFF.T. FIRE TREATEDGA GAUGEGALV. GALVANIZED
INSUL. INSULATIONINT. INTERIORMATL MATERIALMAX. MAXIMUMMECH. MECHANICALMFR. MANUFACTURERMIN. MINIMUMMISC. MISCELLANEOUSM.O. MASONRY OPENINGN.I.C. NOT IN CONTRACTNTS NOT TO SCALEO.C. ON CENTEROPP OPPOSITE HANDPLMB PLUMBINGP.T. PRESSURE TREATEDRAD. RADIUSRCP REFLECTED CEILING PLANREINF. REINFORCEMENTREQD REQUIREDR.L. RAIN LEADERR.O. ROUGH OPENINGS.A.B. SOUND ATTENUATION BATTSIM. SIMILARSTD STANDARDTELE. TELEPHONET&G TOUNGUE AND GROOVETHK THICKNESST.O. TOP OFTYP TYPICALU.N.O. UNLESS NOTED OTHERWISEV.I.F. VERIFY IN FIELDWWF WELDED WIRE FABRICWWM WELDED WIRE MESH
DRAWING TITLE MARK
DETAIL NUMBER
3A201
DRAWING TITLESCALE
SHEET NUMBER
SECTION MARK
3A201
DETAIL NUMBER
SHEET NUMBER
ELEVATION MARK
DETAIL NUMBER3
A201SHEET NUMBER
DETAIL CALLOUT
3A201
DETAIL NUMBER
SHEET NUMBER
FRAME ELEVATION
F17FRAME ELEVATION NUMBER
DOOR NUMBER
123
A
1
COLUMN GRID
EXISTING COLUMN LINE
NEW COLUMN LINE
SYMBOL LEGEND
1 EXISTING COLUMN LINE
Rev Date Comments12.20.12 Permit Set
EXTERIOR RENDERING FOR REFERENCE ONLY, NOT FOR CONSTRUCTION
27' - 0"
27' - 0"
T.O. PARAPET
T.O. CANOPY
S-3 22' - 0"
T.O. PARAPET
T.O. PARAPET
T.O. PARAPET S-1
S-2
S-4
EIFS-1
M-1
CF-3CF-2
EIFS-1
M-1
OPEN
ABE CHP JLNR
EIFS-1
SIGN "S-4", BY SIGNVENDOR, IS 29 SF (+/-)
DLS - 30 2'-6" x VARIES
SIGN "S-2", BY SIGNVENDOR, IS 49 SF (+/-)
EMB - 8'x10' SIGN "S-1", BY SIGNVENDOR, IS 66 SF (+/-)HNL - 30 2'-6" x 22'-5 15/32"
SIGN "S-3", BY SIGNVENDOR, IS 30 SF (+/-)SCL - 24 2'-0" x 20'-11 3/4"
2A602
1A602
4A602
3A602 D
B.O. PARAPET
CMU−1
M−1
EP−1
M−3
M−2
STRUCTURE
FRONT EDGE
UNDERSIDE
COLUMN
FOOTING101A101B
15' - 0"
FG
3' - 0"
EQ SIGNAGE EQ
EQ SIGNAGE EQ
M−2
M−3
EQEQ
EQ EQ EQ EQ EQ EQS-5S-5REVEAL REVEAL REVEAL
2' -
8"4'
- 0"
CF−1
EIFS−1
M−2
ALI
GN
ALI
GN
EQ EQ
ALI
GN
ALI
GN
EQ EQ EQ EQ EQ EQ
M−231' - 0"
ALI
GN
10' - 0"
F52F53F54F55 F57F51
EQ EQ EQEQ1 EQ1 EQ2 EQ2 EQ2 EQ3 EQ3 EQ3 EQ4 EQ4 EQ4
F51
1A607Q
15' -
8"
A501a5
0' - 0"
SHOWROOMF.F.E.
O M K I M2
NEW VEHICLE DELIVERY - M-2 / M-3
25' - 4 1/2"
SHOWROOM - EIFS 1
98' - 11 1/2"
ENTRANCE CYLINDER - M-2
30' - 0"
GL−1
IMPACT RESISTANTNOA - 09-1022.01
GL−1
IMPACT RESISTANTNOA - 09-1022.01
GL−1
IMPACT RESISTANTNOA - 09-1022.01
GL−1
IMPACT RESISTANTNOA - 09-1022.01
SHOWROOM - EIFS - 1
32' - 5"
SERVICE DRIVE - EIFS - 1
43' - 0"
22' - 0"
0' - 0"
NEW EXISTING
27' - 0"
T.O. PARAPET
T.O. PARAPET
F.F.E.
EIFS-1
0' - 0"
S-2
S-1
CF-2
CF−1 CF−1
CF−1
T.O. PARAPET F.F.E.
T.O. PARAPET F.F.E.
F.F.E.
2 4 113 14
12' - 11"
16' - 5"
10 123A601
1A601
4A601
2A601
5A601
T.O. PARAPET
-1' - 6"
M-2
CMU−1
137 136
1
101A
9
135 134B
EIFS−1
EIFS−1
M−2
ALI
GN
ALI
GN
ALI
GN
ALI
GNALI
GN
ALI
GN
ALI
GN
ALI
GN
ALI
GN
2' -
0"4'
- 0"
4' -
0"4'
- 0"
8' -
0"4'
- 0"
1' -
0"
31' - 0"
EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ
8
140 138
M-1
F58 F59 F60 F60
6A601136 M1
EP−1
EXTERIOR SERVICEWALLS AND DOORS
GL−1
IMPACT RESISTANTNOA - 09-1022.01
GL−1
IMPACT RESISTANTNOA - 09-1022.01
GL−1
IMPACT RESISTANTNOA - 09-1022.01
PROPOSED SERVICE DRIVE
121' - 8"
PROPOSED SHOWROOM
56' - 7"
S-1 "HONDA" Brand name with internalillumination.
S-2 "H" logo mounted on Entry Portal with no internal illumination.
S-3 "SERVICE CENTER" logo mounted on service entrance wall with internal illumination.
S-4 "AutoNation" Dealer name with internal illumination
S-5 "Express Service" Oval sign. EG-13BSize 5' - 0" x 1' - 5 5/8"
NOTE:ALL SIGNAGE SHOWN FOR INFORMATIONAND LOCATION ONLY. SIGNAGE SHALL BEPERMITTED & INSTALLED BY OTHERS. G.C.SHALL INSTALL BLOCKING AND PROVIDEELECTRIC CONDUITS AND J-BOXES ASNECESSARY.NOTE:G.C. TO COORDINATE WITH SIGN VENDOREXACT SIZE OF ALL EXTERIOR SIGNAGE.PLEASE CONTACT PLASTI-LINE, INC.(800) 444-7446 FOR MORE INFORMATION.
SIGNAGE LEGEND
M-1
EXTERIOR MATERIAL & FINISH SCHEDULE :
METAL PANEL SYSTEM
CODE MATERIAL
ALUCOBOND OR REYNOBOND
MANUFACTURER
WHITE
COLOR
M-2 METAL PANEL SYSTEM ALUCOBOND OR REYNOBOND HONDA BLUE (PMS 285C)
M-3 METAL PANEL SYSTEM ALUCOBOND OR REYNOBOND SUNRISE SILVER METALLIC
EXTERIOR FACADE, ACCENT
REMARKS
EDGES OF CANOPIES, ENTRANCE CYLINDER
UNDER CANOPIES
EIFS-1 EXTERIOR INSULATION & FINISH SYSTEM DRYVIT HONDA NATURAL WHITE (HOND011021) -
SF-1 ALUMINUM STOREFRONT FRAMING KAWNEER CLEAR ANODIZED ALUMINUM EXTERIOR : VG 451T CENTER-SET. ALL GLASSDOORS AND WINDOWS TO BE IMPACT RESISTANT
CF-1 METAL PARAPET CAP FLASHING METAL-ERA PERMA-TITE TAPERED TO MATCH M-1 -
CF-2 METAL PARAPET CAP FLASHING METAL-ERA PERMA-TITE TAPERED TO MATCH M-2 -
CF-3 METAL PARAPET CAP FLASHING METAL-ERA PERMA-TITE TAPERED TO MATCH M-3 -
EP-1 EXTERIOR PAINT SHERWIN WILLIAMS #SW2423 POLAR WHITE (MATCH EIFS-1) -
CMU-1 CONCRETE MASONRY UNIT ANCHOR CONCRETE PRODUCTS SD-36 -
GL-1 EXTERIOR GLASS - CLEAR LOW E IMPACT RESISTANT NOA - 09-1022.01
A
B
C
B6' - 1 5/8" 7' - 11 3/4" 5' - 6 1/4" 7' - 11 3/4" 5' - 6 1/4" 7' - 11 3/4" 2' - 9 1/8"
6' - 9" 6' - 9" 6' - 9" 6' - 9" 6' - 9" 6' - 9" 3' - 4 1/2"
R 4
' - 1
0 1/
2"
R 5' - 11 1/2"
R 4
' - 1
0 1/
2"
R 5' - 11 1/2"
1' - 1" 1' - 1
"
1' -
11 1
/4"
2' -
1 5/
8"
1' -
11 1
/4"
18' - 10 1/4"
15' - 8"
TOP SIDE
LOW SIDE
2' -
1 1/
8"1'
- 1"DC
B
1' - 1
"
1' -
11 1
/4"
R 4'
- 10
1/2
"
R 5' - 11 1/2"
R 4
' - 1
0 1/
2"
2' -
1 5/
8"
2' -
1 5/
8"
Sheet Number:
Project Number:Drawn By:Checked By:Approved By:
Sheet Title:
Project:
Client:
Copyright (c) 2012 YSM Design, P.C.
All reports, plans, specifications, computer files, field data, notes and otherdocuments and instruments prepared by YSM Design, P.C. shall retain allcommon law, statutory and other reserved rights, including copyrightthereto.
This drawing may not be reproduced in whole or in part without writtenpermission of YSM Design. It is to be returned upon request. Scales asstated are only valid on the original drawings.
Signed & Sealed:
1320 Ellsworth Industrial BlvdSuite A-100Atlanta GA 30318404-249-4555 tel404-355-6394 fax
www.ysmdesign.com
AUTOMOTIVERETAIL ARCHITECTURE
4/9/
2013
7:2
9:38
PM
A501a
Exterior Elevations I
11050EGBYBY
MarooneHondaHollywood
Autonation Inc.
200 SW 1st Avenue 14th FloorFort Lauderdale, FL 33301
2400 North 60th AveHollywood, Broward County, FL
1/8" = 1'-0"A501a
Proposed East Elevation1
1/8" = 1'-0"A501a
Proposed North Elevation3
NOTE ALL SPOT ELEVATIONS AREREFERENCE OFF OF SHOWROOM
F.F.E. REFER TO CIVIL / ALTADRAWINGS FOR ESTABLISHEDGRADE OF SHOWROOM F.F.E.
1/2" = 1'-0"A501a
Honda Canopy Elevation5
1
Rev Date Comments12.20.12 Permit Set
1 04.08.13 Revision 1
27' - 0"
-1' - 6"
T.O. PARAPET
T.O. PARAPET
T.O. PARAPET F.F.E.T.O. PARAPET
T.O. PARAPET
F.F.E.
CF−1
CF-2
OPEN
A B EC H PJ L N R2A602
1A602
4A602
3A602D
0' - 0"
16' - 5"
CF−1
10' - 0"
B.O. PARAPET
31' - 0"
EP−1CMU−1
F G
15' - 0"
T.O. PARAPET
EIFS−1
EIFS−122' - 0"
Q
-1' - 6"
SHOWROOM F.F.E.
SHOWROOM F.F.E.
OMKIM2
CF−1
EIFS−1
EXTERIOR SERVICEWALLS AND DOORS
12' - 0" 12' - 0" 12' - 0" 12' - 0" 12' - 0" 12' - 0" 12' - 0" 12' - 0" 12' - 0" 12' - 0" 12' - 0" 12' - 0"
4' -
0"
ALI
GN
ALI
GN
12' - 0" 12' - 0" 12' - 0" 12' - 0"
27' - 0"
0' - 0"
T.O. PARAPET
T.O. PARAPET
T.O. PARAPET F.F.E.
T.O. PARAPET F.F.E.
F.F.E.
T.O. PARAPET
M-2
S-4
CF-2 2411 3
-1' - 6"
14
16' - 5"
12' - 11"
10123
A6011
A601
4A601
2A601
5A601
NEWEXISTING
162A
111B 100B 109B 108B
M-2
27' - 0"
CMU−1
M−1
EP−1
M−3
M−2
101B
STRUCTURE
FRONT EDGE
UNDERSIDE
COLUMN
FOOTING
EP−1EP−1CMU−1
1
ROOF LINE
9
CF−1
CF−1
EIFS−1
EIFS−1
5' -
0"4'
- 0"
4' -
0"4'
- 0"
4' -
0"4'
- 0"
3' -
6"
1/2" EIFSREVEAL
31' - 0"
7 5
15' - 0"
86A601 13 6M1
EIFS−1
EXTERIOR SERVICEWALLS AND DOORS
EXTERIOR SERVICEWALLS AND DOORS
GL−1
IMPACT RESISTANTNOA - 09-1022.01
GL−1
IMPACT RESISTANTNOA - 09-1022.01
12' - 0"12' - 0"12' - 0"12' - 0"
4' -
0"
12' - 0" 12' - 0" 12' - 0"
12' - 0" 12' - 0" 12' - 0" 12' - 0" 12' - 0"
4' -
0"
S-1 "HONDA" Brand name with internalillumination.
S-2 "H" logo mounted on Entry Portal with no internal illumination.
S-3 "SERVICE CENTER" logo mounted on service entrance wall with internal illumination.
S-4 "AutoNation" Dealer name with internal illumination
S-5 "Express Service" Oval sign. EG-13BSize 5' - 0" x 1' - 5 5/8"
NOTE:ALL SIGNAGE SHOWN FOR INFORMATIONAND LOCATION ONLY. SIGNAGE SHALL BEPERMITTED & INSTALLED BY OTHERS. G.C.SHALL INSTALL BLOCKING AND PROVIDEELECTRIC CONDUITS AND J-BOXES ASNECESSARY.NOTE:G.C. TO COORDINATE WITH SIGN VENDOREXACT SIZE OF ALL EXTERIOR SIGNAGE.PLEASE CONTACT PLASTI-LINE, INC.(800) 444-7446 FOR MORE INFORMATION.
SIGNAGE LEGEND
M-1
EXTERIOR MATERIAL & FINISH SCHEDULE :
METAL PANEL SYSTEM
CODE MATERIAL
ALUCOBOND OR REYNOBOND
MANUFACTURER
WHITE
COLOR
M-2 METAL PANEL SYSTEM ALUCOBOND OR REYNOBOND HONDA BLUE (PMS 285C)
M-3 METAL PANEL SYSTEM ALUCOBOND OR REYNOBOND SUNRISE SILVER METALLIC
EXTERIOR FACADE, ACCENT
REMARKS
EDGES OF CANOPIES, ENTRANCE CYLINDER
UNDER CANOPIES
EIFS-1 EXTERIOR INSULATION & FINISH SYSTEM DRYVIT HONDA NATURAL WHITE (HOND011021) -
SF-1 ALUMINUM STOREFRONT FRAMING KAWNEER CLEAR ANODIZED ALUMINUM EXTERIOR : VG 451T CENTER-SET. ALL GLASSDOORS AND WINDOWS TO BE IMPACT RESISTANT
CF-1 METAL PARAPET CAP FLASHING METAL-ERA PERMA-TITE TAPERED TO MATCH M-1 -
CF-2 METAL PARAPET CAP FLASHING METAL-ERA PERMA-TITE TAPERED TO MATCH M-2 -
CF-3 METAL PARAPET CAP FLASHING METAL-ERA PERMA-TITE TAPERED TO MATCH M-3 -
EP-1 EXTERIOR PAINT SHERWIN WILLIAMS #SW2423 POLAR WHITE (MATCH EIFS-1) -
CMU-1 CONCRETE MASONRY UNIT ANCHOR CONCRETE PRODUCTS SD-36 -
GL-1 EXTERIOR GLASS - CLEAR LOW E IMPACT RESISTANT NOA - 09-1022.01
Sheet Number:
Project Number:Drawn By:Checked By:Approved By:
Sheet Title:
Project:
Client:
Copyright (c) 2012 YSM Design, P.C.
All reports, plans, specifications, computer files, field data, notes and otherdocuments and instruments prepared by YSM Design, P.C. shall retain allcommon law, statutory and other reserved rights, including copyrightthereto.
This drawing may not be reproduced in whole or in part without writtenpermission of YSM Design. It is to be returned upon request. Scales asstated are only valid on the original drawings.
Signed & Sealed:
1320 Ellsworth Industrial BlvdSuite A-100Atlanta GA 30318404-249-4555 tel404-355-6394 fax
www.ysmdesign.com
AUTOMOTIVERETAIL ARCHITECTURE
4/9/
2013
7:3
1:28
PM
A501b
Exterior Elevations II
11050EGBYBY
MarooneHondaHollywood
Autonation Inc.
200 SW 1st Avenue 14th FloorFort Lauderdale, FL 33301
2400 North 60th AveHollywood, Broward County, FL
1/8" = 1'-0"A501b
Proposed West Elevation1
1/8" = 1'-0"A501b
Proposed South Elevation2
Rev Date Comments
LOAD
ING
BUILDING 'A'PROPOSED
MAROONE HONDAHOLLYWOOD
SHOWROOM/OFFICEBUILDING
F.F.E. = 9.00 N.A.V.D.51,295 SF
2,200 SF MEZZANINE
LOAD
ING
LOAD
ING
NEW D
ELIVERY/
CANOPY AREA
RECONSTRUCT FLOOR SLAB TO
ELEVATION F.F.E. = 7.50 N.A.V.D.
SERVICE
RECEPTION
6,436 SF
LOAD
ING
BUILDING 'A'PROPOSED
MAROONE HONDAHOLLYWOOD
SHOWROOM/OFFICEBUILDING
F.F.E. = 9.00 N.A.V.D.51,295 SF
2,200 SF MEZZANINE
LOAD
ING
LOAD
ING
NEW D
ELIVERY/
CANOPY AREA
RECONSTRUCT FLOOR SLAB TO
ELEVATION F.F.E. = 7.50 N.A.V.D.
SERVICE
RECEPTION
6,436 SF
N.W
. 61S
T A
VE
NU
E
THOMAS ST
LEE ST
LEE ST.
U.S
. HW
Y N
o. 4
41
(ST
AT
E R
OA
D N
o. 7
)
(N. 6
0th
AV
E.)
U.S
. HW
Y N
o. 4
41
(ST
AT
E R
OA
D N
o. 7
)
(N. 6
0th
AV
E.)
SHERIDAN ST.(NW 25th ST.)
G:\HODGEN\2010\F100121-FUTURE HOLLYWOOD HONDA\SITEPLAN\F100121-OVERALL SITE PLAN----->LAYOUT: OVERALL SITE PLAN
SHEET TITLE:
SHEET NUMBER:
PROJECT No.:
DRAWN BY:
CHECKED BY:
DATE:
SCALE:
CAD I.D.:
REVISIONS :
PROJECT:
FOR
F100121-OVERALL SITE PLAN
AS NOTED
LA
ND
SCA
PE A
RC
HIT
EC
TS
EN
VIR
ON
ME
NT
AL
CO
NSU
LT
AN
TS
CIV
IL &
CO
NSU
LT
ING
EN
GIN
EE
RS
SUR
VE
YO
RS
PRO
JEC
T M
AN
AG
ER
ST
OW
SO
N, M
D
BO
WIE
, M
D
PU
RC
HA
SE
, N
Y
AL
BA
NY
, N
Y
SO
UT
HB
OR
OU
GH
, M
A
OF
FIC
ES
:
CO
RP
OR
AT
E O
FF
IC
E:
WA
RR
EN
, NJ
ST
ER
LIN
G, V
A
RO
NK
ON
KO
MA
, N
Y
CH
AL
FO
NT
, P
A
WA
RR
EN
TO
N, V
A
CE
NT
ER
V
AL
LE
Y, P
A
FO
RT
L
AU
DE
RD
AL
E, F
L
TA
MP
A, F
L
HOLLYWOODHONDA
HODGENCONSTRUCTION
CITY OF HOLLYWOOD
BROWARD COUNTY, FLORIDA
F100121
JFV
GB
10-01-12
1 03/12/13
BCEPD
COMMENTS
AAM
. .
.
.
.
. .
.
.
.
. .
.
.
.
. .
.
.
.
. .
.
.
.
. .
.
.
.
. .
.
.
.
. .
.
.
.
. .
.
.
.
. .
.
.
.
. .
.
.
.
1000 CORPORATE DRIVE, SUITE 250
FORT LAUDERDALE, FL 33334
PH: (954) 202-7000
FX: (954) 202-7070
www.BohlerEngineering.com
RADICE III
PROFESSIONAL ENGINEER
FLORIDA LICENSE No. 58629
May 8, 2013
C-5
OVERALLSITE PLAN
1"= 50'
0 5012.52550
VARIANCE REQUEST REQUIRED PROPOSED
1. PARKING LOT SETBACKS
EAST 10' 5' (NORTH OF ENTRY)
2. VEHICULAR USE OPEN AREA 25% (60,086 SF) 11.4% (27,354 SF)
ALLOWABLE PROVIDED
3. MAXIMUM SIGN AREA 150 SF 328 SF
4. NUMBER OF SIGNS PER FACADE 1 WALL SIGN PER 7 SIGNS
STREET FRONTAGE
ADDRESS: 2400 N. 60th AVENUE, HOLLYWOOD, FL
CURRENT USE: AUTO SALES, REPAIR AND SERVICE
PROPOSED USE: AUTO SALES, REPAIR AND SERVICE
ZONE DESIGNATION: SR7-CCD-MHC, C-4
LAND USE DESIGNATION: GENERAL BUSINESS
PROJECT LOT AREA : 390,595 SF (8.97 AC)
LESS 18' ALLEY: 15,623 SF (0.36 AC)
LESS FDOT R.O.W. DEDICATION: 2,594 SF (0.06 AC)
NET PARCEL AREA: 372,378 SF (8.55 AC)
BUILDING SETBACKS REQUIRED PROPOSED
NORTH 0' 66.4'
SOUTH 0' 55.7'
EAST 0' 62.6'
WEST 15' 34.5'
STRUCTURE: AREA (SF) USE RATE REQUIRED SPACES
BUILDING A (TOTAL BUILDING SF INCLUDING MEZZANINE = 53,495 SF)
44,795 SF SERVICE / SHOWROOM / OFFICE 1 SPACE PER 400 SF 112
8,700 SF WAREHOUSE / PARTS 1 SPACE PER 1,000 SF 8.9
BUILDING B 16,050 SF AUTO REPAIR 1 SPACE PER 400 SF 40.1
BUILDING C 1,753 SF SHOW ROOM 1 SPACE PER 400 SF 4.4
EXTERIOR 112,926 SF VEHICLE DISPLAY/ INVENTORY 1 SPACE PER 10,000 SF 11.3
TOTAL PARKING REQUIRED: 177 (6 HC)
TOTAL PARKING PROVIDED: 178 (7 HC)
TOTAL INVENTORY PARKING PROVIDED: 387
LOADING ZONE REQUIRED: 3 PROVIDED: 3
*EXISTING AND PROPOSED PERVIOUS AND IMPERVIOUS AREAS REFLECT NET PARCEL AREA LESS 18' ALLEY AND RIGHT-OF-WAY DEDICATION.
NOTES:
1. MAXIMUM FOOT-CANDLE LEVEL ADJACENT TO RESIDENTIAL PROPERTY SHALL NOT EXCEED A MAX. OF 0.5.
2. THERE WILL BE NO ALARM FACING RESIDENTIALLY ZONED PROPERTIES.
3. ALL NEW TERMINAL ISLANDS SHALL BE 190 SF MIN.
4. VEHICLE DISPLAY AREA IN FRONT OF BUILDING WAS NOT COUNTED TOWARDS PARKING.
5. DISPLAY & INVENTORY SPACES TO BE 8.5' x 18 & INCLUDE 22' DRIVE AISLES
6. NO NEW GARAGE DOORS ARE PROPOSED WITHIN 100' OF RESIDENTIALLY ZONED PROPERTY.
7. EXISTING VEHICULAR USE AREE OPEN SPACE IS 2.4%
IMPERVIOUS:
BUILDING AREA:
BUILDING A (FIRST FLOOR): 51,295 SF
MEZZANINE 2,200 SF
BUILDING B: 16,050 SF
BUILDING C: 1,753 SF
BUILDING D + E (DEMOLISHED) (1,292 SF)
TOTAL BUILDING AREA FOOT PRINT: 69,098 SF
CONC. SERVICE RECEPTION AREA: 6,436 SF
CONC. VEHICLE DISPLAY / SIDEWALK: 15,943 SF
VEHICLE USE AREA: 240,343 SF (THIS AREA USED FOR REQUIRED OPEN AREA)
TOTAL PROPOSED IMPERVIOUS: *331,820 SF (89%)
PERVIOUS:
LANDSCAPE BUFFER: (EAST & NORTH) 9,387 SF
INTERNAL LANDSCAPE: 31,171 SF
VUA PERVIOUS 27,354 SF
INVENTORY PERV. 3,817 SF
TOTAL PROPOSED PERVIOUS: *40,558 SF (11%)
EXISTING PERVIOUS *10,232 SF (2.8%)
TOTAL AREA *372,378 SF (100%)
EXISTING
BUILDING
TO REMAIN
LEGENDCUSTOMERPARKING SPACES
VEHICLEINVENTORY SPACES
VEHICLE
DISPLAY/
INVENTORY
AREA
LEGAL DESCRIPTION
PARKING LOT SETBACKS REQUIRED PROPOSED
NORTH 10' 66.4'
SOUTH 10' 55.7'
EAST 10' 62.6'
LANDSCAPE BUFFERS
WEST 10' 34.5'
EXIST. 18'
ALLEY
EASEMENT
O.R.B. 4823,
PAGE 208
PROPOSED
CONCRETE
HATCH LEGEND
EXISTING
CONCRETE
FDOT
DEDICATION
AREA
BUILDING HEIGHT (176' MAX)
BUILDING 'A' 31'
BUILDING 'B' ±30'
BUILDING 'C' ±18'
BUILDING 'D + E' (DEMO'D) 12'
SITE DATA