marley hot & cold water -...

19
MARLEY HOT & COLD WATER Showcase www.marleypipesystems.co.za

Upload: dangliem

Post on 19-Jun-2018

246 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: MARLEY Hot & CoLd WAtER - AutoSpecfiles.autospec.com/.../marley-hot-an-cold-water-show-and-sell.pdf · MARLEY Hot & CoLd WAtER Showcase ... Fitting the expansion valve vertically

MARLEY Hot & CoLd WAtER Showcase

www.marleypipesystems.co.za

Page 2: MARLEY Hot & CoLd WAtER - AutoSpecfiles.autospec.com/.../marley-hot-an-cold-water-show-and-sell.pdf · MARLEY Hot & CoLd WAtER Showcase ... Fitting the expansion valve vertically

INdEX

INTRODUCTION

PRODUCTS LATCO Pro-Fit

TECHNICAL VIEW LATCO Pro-fit

INSTALLATION LATCO Pro-fit

..............

..............

..............

..............

..............

..............

..............

02

03 - 0506 - 10

0306

1212

1314

15 - 16

17

18

19

..............

..............

..............

..............

..............

..............

FAQ LATCO Pro-Fit

CASE STUDY

MARKETING SUPPORT

TRAINING

CONTACT US

Southern African Vinyls Association

01

Page 3: MARLEY Hot & CoLd WAtER - AutoSpecfiles.autospec.com/.../marley-hot-an-cold-water-show-and-sell.pdf · MARLEY Hot & CoLd WAtER Showcase ... Fitting the expansion valve vertically

INtRodUCtIoN

Marley Pipe Systems, an Aliaxis company, is recognised as the trust-edname influidhandlingsolutionsthroughout southern Africa, offering anextensiverangeofpipesandfit-tings, and related products that set the standard for quality, compliance and customer satisfaction in the plumbing and building market.

For over five decades, we haveserved as a dynamic partner with integrity for our clients, our people, our suppliers and our market. The capacity to supply a comprehen-sive, quality focused product range

coupled with the ability to provide a complete merchandising solu-tion and product support structure is what sets us apart.

It is these values of quality and servicethatcontinuetodefineusas a company as we consistent-ly strive to deliver high level cus-tomer experiences throughout the value chain from factory floor toend-consumer and everything in between.

Southern African Vinyls Association

02www.marleypipesystems.co.za

YoUR EXPERIENCEd PARtNER IN FLUId HANdLING SoLUtIoNS

Page 4: MARLEY Hot & CoLd WAtER - AutoSpecfiles.autospec.com/.../marley-hot-an-cold-water-show-and-sell.pdf · MARLEY Hot & CoLd WAtER Showcase ... Fitting the expansion valve vertically

03

LAtCo PRESSURE REGULAtING VALVESCONVENIENCE AND QUALITY IN ONE SYSTEM

LATCO presents a reliable generation of pressure regulating valves and pressure con-trol valves for hot and cold water systems that saves time and money, offering maxi-mum value at unbeatable prices.

Manufactured from a tough, corrosion resistant Acetal copolymer, LATCO Standard has been in use for over 35 years on a substantial number of dwellings without change to its principal design.Thebenefits of plastic over copper andbrassalternatives isthat there is no electrolytic action with the water and no scale build up. Another key advantage of LATCO valves is that they have no scrap value meaning that there is less pilferage from merchants and building sites.

The range is available in 100kPa, 200kPa, 400kPa and 600kPa models for both BSP and CC connections, and is compatible with all SANS 151 compliant hot water cylin-ders.

www.marleypipesystems.co.za

1. LATCO Neptune Pressure Control Valve 2. LATCO Expansion Relief Valve3. Hot Water Cylinder 4. Temperature & Pressure Safety Valve with separate 5. LATCO Vacuum Breaker 6. Hot Water Pipe7. Drip Tray 8. Pipework to Mixer / Taps9. Drip Tray Outlet Pipe10. Cold Water Inlet Pipe11. Stopcock

1

79

10

11

8

2

3 45

6

Page 5: MARLEY Hot & CoLd WAtER - AutoSpecfiles.autospec.com/.../marley-hot-an-cold-water-show-and-sell.pdf · MARLEY Hot & CoLd WAtER Showcase ... Fitting the expansion valve vertically

04

LAtCo PRodUCtRANGE

www.marleypipesystems.co.za

STANDARD LATCO - 100KPA

LAT27Twin Pack

LAT25 Pressure Control Valve

LAT26 Relief Valve

NEPTUNE BLUE - 100KPA

LAT12Twin Pack - BSP

LAT10Pressure Control Valve- BSP

LAT11Relief Valve - BSP

NEPTUNE BLACK - 200KPA

LAT15Twin Pack - BSP

LAT13Pressure Control Valve- BSP

LAT14Relief Valve - BSP

Page 6: MARLEY Hot & CoLd WAtER - AutoSpecfiles.autospec.com/.../marley-hot-an-cold-water-show-and-sell.pdf · MARLEY Hot & CoLd WAtER Showcase ... Fitting the expansion valve vertically

05

LAtCo PRodUCtRANGE

www.marleypipesystems.co.za

NEPTUNE RED - 400KPA

LAT18Twin Pack - BSP

LAT16Pressure Control Valve- BSP

LAT17Relief Valve - BSP

LAT18CTwin Pack - CxC

LAT18CON“Contractor’s Pack”Including Relief Valve and Vaccuum Breaker

NEPTUNE GREEN - 600KPA

LAT602 Twin Pack - BSP

LAT600Pressure Control Valve- BSP

LAT601 Relief Valve - BSP

VACCUUM BREAKER

LAT49Double Seat, Brass Body - 20mm - BSP

Page 7: MARLEY Hot & CoLd WAtER - AutoSpecfiles.autospec.com/.../marley-hot-an-cold-water-show-and-sell.pdf · MARLEY Hot & CoLd WAtER Showcase ... Fitting the expansion valve vertically

06

PRo-FIt PoLYMERSYStEMLEVERAGING ADVANTAGES IN MATERIAL TECHNOLOGY

Pro-fitisacompletehotandcoldwatersupplysolutionthatissuitableforresidentialandcommercial installations, offering contractors ease of use and up to 50% time savings on installations. This revolutionary hot and cold technology requires minimal training, is cost effective and offers many advantages, some of which include:

Manufactured from the highest grade PE-RT (Polyethylene with Raised Temperature Re-sistance), Pro-fit is tough, puncture and tear resistant and offers greater flexibility with a bending radius of up to 180°, allowing ease of use and the reduction in the use of fittings required.

www.marleypipesystems.co.za

11

○ Corrosion & impact resistance○ No scale build up○ Quieter plumbing○ Healthier water

○ No scrap value○ Decreasedturbulentflow○ Lowco-efficientoffriction○ 100% certain joints

Page 8: MARLEY Hot & CoLd WAtER - AutoSpecfiles.autospec.com/.../marley-hot-an-cold-water-show-and-sell.pdf · MARLEY Hot & CoLd WAtER Showcase ... Fitting the expansion valve vertically

PRo-FIt PRodUCt RANGE

www.marleypipesystems.co.za07

PRO-FIT PIPE

PRP016006Pipe 16mm length 6mPRP020006Pipe 20mm length 6m

PRP016050Pipe 16mm Coil 50mPRP020050Pipe 20mm Coil 50m

PRESSURE SLEEVES

PRFSL16Pressure Sleeve 16mm

PRFSL20Pressure Sleeve 20mm

COUPLINGS

PRFCP16Coupling Equal 16mmPRFCP20Coupling Equal 20mm

PRFCPR2016Coupling Reducing 20mm-16mm

ELBOWS

PRFEL16Elbow 90° 16mmPRFEL20Elbow 90° 20mm

PRFEF1612 Elbow 90° Female 16mm - 1/2”

PRFEC1615Elbow 90° Copper Adaptor 16mm - Cu 15

PRFEM1612Elbow 90° Male 16mm - 1/2”

Page 9: MARLEY Hot & CoLd WAtER - AutoSpecfiles.autospec.com/.../marley-hot-an-cold-water-show-and-sell.pdf · MARLEY Hot & CoLd WAtER Showcase ... Fitting the expansion valve vertically

08www.marleypipesystems.co.za

PRo-FIt PRodUCt RANGE

TEES

PRFTE16Tee Equal 16mm PRFTE20Tee Equal 20mm

PRFTR161620Tee Reducing 16mm-16mm-20mmPRFTR202016Tee Reducing 20mm-20mm-16mmPRFTR201616Tee Reducing 20mm-16mm-16mmPRFTR201620Tee Reducing 20mm-16mm-20mm

PRFTC161516Tee Copper Adaptor 16mm - Cu 15 - 16mm

PRFTM161216Tee Male Branch 16mm - 1/2”

CONNECTORS

PRFCM1612Connector Male 16-1/2”PRFCM1634Connector Male 16-3/4”

PRFCM2012 Connector Male 20-1/2”PRFCM2034Connector Male 20-3/4”

PRFCF1612Connector Female 16-1/2”PRFCF1634Connector Female 16-3/4”

PRFCF2012Connector Female 20-1/2”PRFCF2034Connector Female 20-3/4”

PRFCC1615Copper Adaptor 16mm - Cu 15

PRFCC2022Copper Connector 20mm - Cu 22

Page 10: MARLEY Hot & CoLd WAtER - AutoSpecfiles.autospec.com/.../marley-hot-an-cold-water-show-and-sell.pdf · MARLEY Hot & CoLd WAtER Showcase ... Fitting the expansion valve vertically

www.marleypipesystems.co.za

PRo-FIt PRodUCt RANGE

09

EXTENSIONS

PRFEX1225Extension 1/2” - 25mmPRFEX1220Extension 1/2” - 20mm

PRFEX1215Extension 1/2” - 15mmPRFEX1210Extension 1/2” - 10mm

END PLUGS

PRFPL16End Plug 16mm

PRFPL20End Plug 20mm

WALL OUTLETS

PRFOS1612Wall Outlet 16mm - 1/2”

PRFOS2034Wall Outlet 20mm - 3/4”

PRFOD90Double Entry Wall Outlet - 90° 16mmx1/2”

PRFODPLDouble Entry Wall Outlet - Parallel 16mmx1/2”

REMS - FLARING TOOLS

PRTEXT1620Pipe Flaring Tool (Incl. 16mm & 20mm Expanding Jaws)PRTEXJ16Expanding Jaws 16mmPRTEXJ20Expanding Jaws 20mmPRTEXTPipe Flaring Tool Only

Page 11: MARLEY Hot & CoLd WAtER - AutoSpecfiles.autospec.com/.../marley-hot-an-cold-water-show-and-sell.pdf · MARLEY Hot & CoLd WAtER Showcase ... Fitting the expansion valve vertically

10www.marleypipesystems.co.za

PRo-FIt PRodUCt RANGE

VULCAN - CLOSING TOOLS

PRTCLT1620Pressure Sleeve Closing Tool (Incl 16mm & 20mm Jaws)PRTCLJ16Pressure Sleeve Jaws 16mmPRTCLJ20Pressure Sleeve Jaws 20mmPRTCLTPressure Sleeve Closing Tool Only

REMS - CLOSING TOOLS

PRTCLT1620REMSPressure Sleeve Closing Tool (Incl 16mm & 20mm Jaws)PRTCLJ16REMSPressure Sleeve Jaws 16mm REMSPRTCLJ20REMSPressure Sleeve Jaws 20mm REMSPRTCLTREMSPressure Sleeve Closing Tool Only REMS

DUAL PLATE UNIVERSAL

PRFDARDual Plate Universal RecessedPRFDAFDual Plate Universal - Assembly Unit

SINGLE PLATE

PRFSARSingle Plate RecessedPRFSAFSingle Plate - PlasticPRFSAROSingle Plate - Recessed

Page 12: MARLEY Hot & CoLd WAtER - AutoSpecfiles.autospec.com/.../marley-hot-an-cold-water-show-and-sell.pdf · MARLEY Hot & CoLd WAtER Showcase ... Fitting the expansion valve vertically

1

36

76

8

9

5

2

4

10

INStALLAtIoN

LATCO high pressure control and expansion relief valves should only be installed with SABS approved pressurised electric geysers of the corresponding pressure rating. See

diagram on the next page for further instruction.

By following the installation guidelines below you are guaranteed a high-performing result and many years of

trouble-free use.

www.marleypipesystems.co.za 11

1. LATCO Neptune 100, 200, 400 and 600kPa Twin Packs are factory pre-set and need no adjustment.

2. Valves must be installed above the geyser. By doing so, it is not necessary between the LATCO pressure control valve and the geyser.

3. Fitting the expansion valve vertically will reduce the possibility of dirt lodging in the valve.

4. As heating takes place, the water in the geyser will expand and cause intermittent dripping from the expansion valve – this is normal.

5. The drain from the valve should be protected against freezing andshouldbedischargeddownwardsintoagulley,flowerbed,etc., where expansion drip will not cause annoyance. On no account should expansion drip be discharged over a paved area or directly into waste, soil or vent pipes.

6. Whereveryhighmainspressureexists,rigidlyfixinletcoldwater supply pipe as close to the valve as possible to prevent vibrations.

7. Afterinitiallyfillingthegeyser,closethecoldwatermainssupply and clean all hemp, pipe cuttings, etc., from the valve filter.Thefiltermayberemovedforcleaningbyunscrewingthecapmarked‘filter-sif’ontheinletsideofthevalve.

8. Where hot and cold water feeds to mixing points are not bal-anced,fitanon-returnvalveonthehotwaterdrawofflinetoprevent high pressure cold water being forced back through thesystem.Thisfittingmustnotbeinstalledbetweenthevacuum and geyser outlet.

9. A 25mm expansion pipe must extend at least 2.5m vertically above both the valve and the highest hot water draw off point from the geyser.

10. With all hot taps closed, adjust the water level in the expan-sion pipe by slowly turning the adjusting nut clockwise, until allwaterflowsoutoftheexpansionpipe,thenturntheadjust-ing nut back one full turn.

11. Provide air breaks if the drain: o Exceeds a 6 metre run o Drops more than 1 metre o Runs horizontal after a fall

Page 13: MARLEY Hot & CoLd WAtER - AutoSpecfiles.autospec.com/.../marley-hot-an-cold-water-show-and-sell.pdf · MARLEY Hot & CoLd WAtER Showcase ... Fitting the expansion valve vertically

LAtCoFAQs

www.marleypipesystems.co.za

Can LAtCo Neptune valves be used on unbalanced systems?

Which pressure valve should I use for my system?

Yes, however we recommend that the system be changed to a SANS 10254 balanced system.

The rated pressure of the valve must match the rated pressure of the geyser. The pressure rating of the valve is indicated by colour, i.e. Blue: 100kPa, Black: 200kPa, Red: 400kPa, Green: 600kPa.

The cause would have to be diagnosed further, however possible causes could be a faulty valve or incorrect installation.

If the valve is leaking, there may be dirt in the valve that needs to beflushedandcleaned.

Yes, LATCO Neptune valves are SABS approved, however the LATCO Standard valve (100kPa) is not.

No LATCO is not to be used on systems with an uncontrolled heat source.

Yes, because the LATCO Expan-sion Relief Valve incorporates a vacuum breaker function.

www.marleypipesystems.co.za 13

Why does my LATCO flying saucer leak?

I fitted a new valve yesterday – why is it leaking?

Are LAtCo valves SABS approved?

Can LAtCo valves be used on a system with an uncontrolled heat source?

Is it true that you only need to purchase one vacuum breaker when using the Neptune Twin Pack?

Page 14: MARLEY Hot & CoLd WAtER - AutoSpecfiles.autospec.com/.../marley-hot-an-cold-water-show-and-sell.pdf · MARLEY Hot & CoLd WAtER Showcase ... Fitting the expansion valve vertically

14 www.marleypipesystems.co.za

PRo-FItFAQs

What tools are required to join Pro-fit pipes?

Can connection to copper pipes be made?

No consumables, heat or elec-tricityarerequiredtojoinPro-fitpipe – only a pipe cutter, an expanding tool and a closing tool. NB: a hacksaw should not beusedtocutPro-fitpipe.

Yes.Byusingatransitionfitting,you can easily connect a plastic Pro-fitpipetoanexistingcopperpipe.

Yes,Pro-fitpipesandfittingscarry the SABS mark for SANS10508.

Pro-fitshouldnotbeinstalledoutside to connect a solar geyser as pipes are not UV stabilised and would require additional pro-tection to prevent deterioration from the sun.

No. It is not recommended to use Pro-fitpipeingasinstallations.

Pro-fitPE-RTpipedemonstrateslower thermal conductivity than mild steel and copper pipes, however it is still recommended to use the same precautions against heat loss as required by plumbing codes, regulations and bylaws.

The process of pressurising the line can take place immediately after a joint has been made.

Is the Pro-fit system SABS approved?

Can Pro-fit pipes be installed in a solar geyser set up?

Can Pro-fit be used with gas geyser systems?

Do Pro-fit pipes need to be insulated to prevent heat loss?

When should pressurisation occur when installing Pro-fit pipe?

Page 15: MARLEY Hot & CoLd WAtER - AutoSpecfiles.autospec.com/.../marley-hot-an-cold-water-show-and-sell.pdf · MARLEY Hot & CoLd WAtER Showcase ... Fitting the expansion valve vertically

CASE StUdY: PRo-FIt Hot & CoLd WAtER SYStEM, JoHANNESBURG CBd

Reaching new heights of delivery

In recent years, Joburg has been on a drive to regenerate its inner city to better accommo-date its current and future residents. As part of this huge regeneration strategy, a number of old and dilapidated high rise buildings are being completely stripped and converted into living apartments in areas such as Braamfon-tein, Joubert Park, Yeoville and Doornfontein.

During construction, there were a number of factorsthatwouldinfluencethesuccessfulcompletion of each and every project, one of which was the choice of plumbing system. Op-erating in areas where the crime rate is high, copper parts had to be ruled out due to theft risks on site.

Pro-fitishelpingtoreducethoserisksbyof-fering a polymer-based range of products that make up the hot and cold water system for multi-storey buildings.

tHE CHALLENGE

Marley was initially involved in the project to convert a 17 storey building from copper to Pro-fit.Thesuccessofthisparticularprojectled them to secure a contract for the next building to be renovated, a 29 storey behe-moth that would serve over 450 living apart-ments.

Providing hot and cold water to the upper floorsofhighrisebuildingslikethisisafun-damental requirement and the main challenge for plumbing system engineers who must con-sider a number of variables such as available municipalwaterpressure,flowdemand,pipeand valve materials, riser locations, pressure regulating stations not to mention economics and even acoustics.

Requirements:

Safe and reliable hot and cold water plumbing solution Quick and hassle-free installation and maintenance

one System. Countless Satisfied End Users

StoreyBuilding

Apartments per Floor

totalApartments

29 16 450

www.marleypipesystems.co.zawww.marleypipesystems.co.za 15

Page 16: MARLEY Hot & CoLd WAtER - AutoSpecfiles.autospec.com/.../marley-hot-an-cold-water-show-and-sell.pdf · MARLEY Hot & CoLd WAtER Showcase ... Fitting the expansion valve vertically

A winning system for high rise buildings

For the project,Pro-fitwasusedas part of a fusionPPR (Polypropylene Random) plastic piping system to supply water throughout the building. The lower storeys are supplied directly from the pressure in the public water main while the upper storeys are supplied from pressure-boosted main risers through a pressure reduction valve for each group.

PE (Polyethylene) has been widely used for the safe transport of potable water for more than 35 years with no harmful leaching of elements into the supply line. Addedtothistrackrecord,ThePro-fitsystemisJAS-WIC approved and has been tested and rated in ac-cordance with SANS ISO22391 for hot and cold water supply systems. The ingenuity in design and material propertiesofthesystemofferedmanybenefitsfortheproject:

Ease of installation Increased reliability Reduced costs Reduced noise levels No scrap value

Ensuring value for years to come

For Marley, working on big projects like this one is nev-er just about the sale, it’s about ensuring sustainable installations that add value to everyone it touches. To this end, Marley was closely involved in the project to make sure that contractors and installers had access to expert advice at all times. This included the provi-sion of training to each project team to help familiarise them with the product so that they would be comfort-able using it. On-site technicians were also available to provide fault-finding support for any installationtroubles that were encountered.

The Final Result

Although the project is still in progress, the outcomes of the installations so far have demonstrated the Pro-fitsystem’spowerfulcapabilities.

Helping Joburg meet its promisefor a better future

For the latest product information and local distributors, visit

www.marleypipesystems.co.za

The contractors were impressed by the ease of use, hassle-free oper-ation and cost-effectiveness of the system, as well as the value-added service that was provided. So much so that they are keen to work with the Pro-fit system and Marley again in their next renovation – this one, a 19 storey building.

16 www.marleypipesystems.co.za

Page 17: MARLEY Hot & CoLd WAtER - AutoSpecfiles.autospec.com/.../marley-hot-an-cold-water-show-and-sell.pdf · MARLEY Hot & CoLd WAtER Showcase ... Fitting the expansion valve vertically

MARKEtING SUPPoRt

YOUR SUCCESS IS OURS, SO WE MAKE SURE YOU’VE GOT SUPPORT IN ALL SORTS OF WAYS

An important part of our business philosophy is to build good partnerships and trading relationships with our custom-ers. To do this, a large portion of our service offering is dedicated to providing support for merchants, partners and end users alike.

So,notonlycanpartnershavefullconfidenceinabrandthatcustomerstrust,buttheywillalsohaveaccesstosalesandmarketingsupport,strategicguidanceandmerchandisingplansthathelpoptimiseprofitabilitybymovingprod-ucts off the shelf quicker.

○ Dedicated account service and knowledgeable product support ○ Access to a library of support catalogues and product literature ○ POS display and merchandising solutions tailored to your own needs ○ Promotional campaigns to drive customer adoption

LATCO PRESSURE REGULATING VALVESMarley’s trusted polymer system for pressure control in hot and cold water systems

KEY FEATURES

BENEFITS:

1. Can LATCO valves be used on SANS 10254 balanced systems? Yes.2. Can LATCO Neptune valves be used on unbalanced systems? Yes, however we recommend that the system be changed to a balanced system.3. What pressure valve must I use? The rated pressure of the valve must match the rated pressure of the geyser.4. How can I identify the pressure class of a LATCO valve? The pressure rating of the valve is indicated by colour, i.e. Blue: 100kPa, Black: 200kPa, Red: 400kPa, Green: 600kPa.5. WhydoesmyLATCOflyingsaucer leak? The cause would have to be diagnosed further, however possible causes could be a faulty valve or incorrect installation.6. Ifittedanewvalveyesterday–whyis itleaking?If the valve is leaking, there may be dirt in the valve that needs to be flushedandcleaned.7. Whyisthevalvemakingafunny noise? Pressure and air in the valve may cause it to make a noise.8. Are LATCO valves SABS approved? Yes, LATCO Neptune valves are SABS approved, however the LATCO Standard valve (100kPa) is not.9. Can LATCO valves be used on a system with an uncontrolled heat source? No LATCO is not to be used on systems with an uncontrolled heat source. 10.Is it true that you only need to purchase one vacuum breaker when usingtheNeptuneTwinpack?Yes, because the LATCO expansion relief valve incorporates a vacuum breaker function.

Available as BSP or CC connections Easy installation Available countrywide Proudly manufactured in South Africa No theft risk – no copper parts Corrosion-free No scale build up Compatible with all SANS 151 hot water cylinders UV stabilised

www.marleypipesystems.co.za

Shut-off Seat 8mm Pressure Spring

15mm BSP Male Inlet

Adjusting Nut

D3 Diaphragm 150mm

20mm BSP Female Outlet

LATCO Standard

FREQUENTLY ASKED QUESTIONS

Time proven simplicity of design and reliable operation

Manufactured from tough,corrosion resistant Acetal copolymer

Most affordable pressure regulating valve on the market

Can be installed with an open standpipe or with a relief valve

Outlet 20mm BSP Male

Inlet 20mm BSP Male

Balance Piston

Balance Piston Sleeve

LATCO Neptune

Adjusting Spindle

Expansion Relief andVacuum Breaker Seat

20mm BSP Male Outlet

Pressure Spring

Diaphragm20mm BSP Male Inlet

LATCO ExpansionRelief/Vacuum Breaker

CONNECTING PIPES• Ensureleaktightjoints• Pipesmustbefirmlyanchored

POSITION OF PRESSURE CONTROL VALVE• 100kPAvalvesmustbepositionedcloseto thegeyser(notmorethan2mbelow thecylinder)• Ensureabalancedpressuretoallshowers andmixers• Pressurecontrolvalvemustbeaccessible sothatitcanbeservicedwithoutdrainingall thewater

VACUUM BREAKERS• Mustbefittedonhotsupplyandcoldsupply (expansionreliefvalveincludesvacuum breakerfunction)• Shouldbefittedon300mmrisersonthehot outletpipe(ifcloserthan700mmfromthe outlet)• Onacoldpipe,mustbeinstalledonan anti-syphonloop

TEMPERATURE AND PRESSURE SAFETY VALVE• Mustbecorrectlyfittedintothehotwatercylinder

ACCESS• Mustbeinstalledforsafeoperation• Ensureeasyaccessforrepairsand maintenance• Useenoughunionsandcouplingstoallowfor removalwithoutcuttingpipework

SAFETY TRAY• Allgeysersmustbeinstalledwithasafetytray largeenoughtocapturedropsfromsurrounding valvesandpipework• Mustbefittedoveraload-bearingwalland slopedtowardstheoutlet• Thehotwatercylindermuststandonsupports• Ensureaminimum40mmoutlettodischarge excesswaterfromthetraytotheoutsideofthe building

LOCATION OF ISOLATING VALVE• Mustbeaheadofthepressurecontrolvalve• Ifitisnotalreadypartofthesystem,there shouldbeanisolatingvalveontheexterior ofthebuilding

LATCO PRESSURE REGULATING VALVESMarley’s trusted polymer system for pressure control in hot and cold water systems

COMPONENTSAllcomponentsmustbeinstalledaccordingtoSANS10254.

Checkthepressureratingofthegeysertomatchthepressureratingofthevalve.

GEYSERINSTALLATION & INSPECTION

CHECKLIST

DISCHARGE PIPE FROM VALVES• Nowatertraps• DischargepipesmustNEVERjointogether• Pipesmustbethesamediameterasthevalve outlet• Pipesmustbeinclineddownwardsfrom temperatureandpressuresafetyvalves• Metallicpipesmayonlybeusedfrom temperatureandpressuresafetyvalves• Ensurethatpipesdischargewhereitwillcause nonuisancebutalsosothatthedischargeis visible• Dischargedoverflowmustbedirectedoutside• Maximumlengthfora20mmpipeis4mandfor 28mmpipe,9m• Amaximumof3bendsispermitted

TESTING• Allinstallationsmustbeflushed,inspectedand testedforleakspriortohandover

DONOTinstallanisolatingvalveonthesamelineasthepressurereliefvalve

Itpreventsthenormalfunctioningofapressurereliefvalvetoreleaseexcesspressure

www.marleypipesystems.co.zawww.marleypipesystems.co.za

- 17 -

Y o u r V a l u e P a r t n e r

PRO-FIT HOT & COLD WATER SYSTEM

10508

Pro-fit Pipe Lengths

PRP016006 - Pipe 16mm Length 6mPRP020006 - Pipe 20mm Length 6m

PRP016050 - Pipe 16mm Coil 50mPRP020050 - Pipe 20mm Coil 50m

Pro-fit Pipe Coils Pressure Sleeves Couplings Reducing Couplings

Elbows

PRFSL16 - Pressure Sleeve 16mmPRFSL20 - Pressure Sleeve 20mm

PRFCP16 - Coupling Equal 16mmPRFCP20 - Coupling Equal 20mm

PRFCPR2016 - Coupling Reducing20mm-16mm

PRFEL16 - Elbow 90° 16mmPRFEL20 - Elbow 90° 20mm

Male Branch Tee

PRFTM161216 - Tee Male Branch16mm - 1/2"

PRFTR161620 - 16mm-16mm-20mmPRFTR202016 - 20mm-20mm-16mmPRFTR201616 - 20mm-16mm-16mmPRFTR201620 - 20mm-16mm-20mm

Reducing Tees Copper Tee

PRFTC161516 - Tee Copper Adaptor 16mm - Cu 15 - 16mm

Equal Tees

PRFTE16 - Tee Equal 16mmPRFTE20 - Tee Equal 20mm

Male Connectors Female Connectors Extensions End Plugs

PRFCM1612 - Connector Male 16-1/2"PRFCM1634 - Connector Male 16-3/4"PRFCM2012 - Connector Male 20-1/2"PRFCM2034 - Connector Male 20-3/4"

PRFEX1225 - Extension 1/2" - 25mmPRFEX1220 - Extension 1/2" - 20mmPRFEX1215 - Extension 1/2" - 15mmPRFEX1210 - Extension 1/2" - 10mm

PRFCF1612 - Connector Female 16-1/2"PRFCF1634 - Connector Female 16-3/4"PRFCF2012 - Connector Female 20-1/2"PRFCF2034 - Connector Female 20-3/4"

PRFPL16 - End Plug 16mmPRFPL20 - End Plug 20mm

Wall Outlets

Double Entry Wall Outlet Male Elbow

PRFEM1612 - Elbow 90° Male 16mm - 1/2"

Straight Copper Adaptor/Connector Female Elbow Elbow Connector

AdaptorPRFCC1615 - Copper Adaptor 16mm - Cu 15PRFCC2022 - Copper Connector 20mm - Cu 22

PRFEF1612 - Elbow 90° Female 16mm - 1/2"

PRFEC1615 -Elbow 90° Copper Adaptor 16mm - Cu 15

PRFOS1612 - Wall Outlet 16mm - 1/2"PRFOS2034 - Wall Outlet 20mm - 3/4"

PRFOD90 - Double Entry Wall Outlet - 90° 16mmx1/2”PRFODPL - Double Entry Wall Outlet - Parallel 16mmx1/2”

17www.marleypipesystems.co.za

Page 18: MARLEY Hot & CoLd WAtER - AutoSpecfiles.autospec.com/.../marley-hot-an-cold-water-show-and-sell.pdf · MARLEY Hot & CoLd WAtER Showcase ... Fitting the expansion valve vertically

the price of success is hard work, dedication to the job at hand, and the determination that whether we win or lose, we have applied the best of ourselves to the task at hand.

- Vince Lombardi

tRAINING

EMPoWERING tHE INdUStRY toWARdS BEttER PRodUCt INStALLAtIoNS

Marley is a company that prides itself on nothing but quality – not only in the products that we manufacture, but also the very integrity of the product installations that make up the backbone of every building in South Africa, from a freestanding house to a multi-storey high rise.

As part of our commitment to sustainable development at all levels of the value chain, we strive to create opportunities for skills development. Not only do we offer on-site and classroom training led by industry experts to support plumbers and installers, but we also aim to provide knowledgeable technical training at school and FET level to empower the plumbers and installers of tomorrow.

18 www.marleypipesystems.co.za

Page 19: MARLEY Hot & CoLd WAtER - AutoSpecfiles.autospec.com/.../marley-hot-an-cold-water-show-and-sell.pdf · MARLEY Hot & CoLd WAtER Showcase ... Fitting the expansion valve vertically

CoNtACt USBranch Offices

Bloemfontein: +27 51 434 2331/5Cape Town: +27 21 045 0050Durban: +27 31 791 5800East London: +27 43 726 6505George: +27 44 874 1160Jet Park (MEGAFLEX): +27 11 823 1160Namibia: +264 81 237 200Nelspruit: +27 13 753 2571Polokwane: +27 15 292 4141Port Elizabeth: +27 41 045 0998Zimbabwe +263 772 229 940 Agents: Contract Supplies (Botswana): +267 392 2922

www.marleypipesystems.co.za

Building Head Office1 Bickley Road,Pretoriusstad, NigelTel: +27 11 739-8600Fax: +27 11 739-8680

Mining and IndustrialHead Office1 Piet Pretorius Street,Rosslyn, PretoriaTel: 0861 MARLEYTel: +27 12 045-0997

ENQUIRE HERE