The presentation(s)/poster(s) in this publication comprise the Proceedings of the 2017 BiTS Workshop. The content reflects the opinion of the authors and their respective companies. They are reproduced here as they were presented at the 2017 BiTS Workshop. This version of the presentation or poster may differ from the version that was distributed in hardcopy & softcopy form at the 2017 BiTS Workshop. The inclusion of the presentations/posters in this publication does not constitute an endorsement by BiTS Workshop or the workshop’s sponsors. There is NO copyright protection claimed on the presentation/poster content by BiTS Workshop. However, each presentation/poster is the work of the authors and their respective companies: as such, it is strongly encouraged that any use reflect proper acknowledgement to the appropriate source. Any questions regarding the use of any materials presented should be directed to the author(s) or their companies. The BiTS logo and ‘Burn-in & Test Strategies Workshop’ are trademarks of BiTS Workshop. All rights reserved.
BiTS 2017 Poster Session
Burn-in & Test Strategies Workshop
www.bitsworkshop.org March 5-8, 2017
Air Cooled Thermal Tool for System Level
High Volume Manufacturing Testing
Rahima Mohammed, Ridvan Sahan, Ying-feng Pang,
Amy Xia, Hagai Wertheim
Intel Corporation
Thermal Margining tools are used to:
Air-cooled thermal tools (ACTT) remove the liquid detection, harness management issues, and lab infrastructure needs
Design a new low cost high volume manufacturing (HVM) ACTT
solution for System level testing automation environment for Client
Multi-dies with Central Processing Unit (CPU) and Peripheral
Component Hub (PCH) for 2 in 1’s, laptop etc.
Thermal Design Target : CPU Cold Plate Temp (Tcp ) 40 °C @ 30 W
CPU Tcp 60 °C to 85 °C @ 65 W
Keep Out Zone (KOZ) of the ACTT: Active Heatsink (HS) Keep out volume
(KOV) of 45 mm x 60 mm x 26 mm, Single-staged Thermoelectric cooler
(TEC) and the pedestal Kit
Accelerate Fault Detection Identify Bugs
Test and Validate Silicon Thermal Design Power Extraction
Reduce Escapes Cooling and Margining capability
INTRODUCTION
Goal
Active HS design with 2 central heat pipes (HP) (CFD Model (left), actual
design (right)) 2 Fans
Pushing
2 Fans
Pulling
BiTS 2017 Poster Session
Burn-in & Test Strategies Workshop
www.bitsworkshop.org March 5-8, 2017
BiTS 2017 Air Cooled Thermal Tool for System Level High Volume Manufacturing Testing 2
CPU PCH
Final Design for TDP = 30 W with 1 30x30 mm TEC, 2 of 5 mm heatpipe,
Fan Size: 30 x 30 x 15 mm (Sun Tai 24 V) 2 PUSH 2 PULL (QUAD FAN)
CPU PCH
Temperature
Profile for
65 W TDP
Temperature
Profile for
30 W TDP
17.1 14.9
0
5
10
15
20
25
No Heatpipe Y (2 5mmDiagonal)
Y (2 of 5mmCenter)
Y (2 of 5mmCenter)
Y (2 of 5mmCenter)
Y (2 of 5mmCenter)
ICoolPSC30x30x15(4) Push
Pull
ICoolPSC30x30x15(4) Push
Pull
ICoolPSC30x30x15(4) Push
Pull
IcoolPSC40x40x28
(1)
Sun Tai30x30x15(2) Push
Pull
Sun Tai30x30x15(4) Push
Pull
I II III IV V VI
CPU Tcp (°C) PCH Tcp (°C)
Uniform TDP (W) Tcp (°C)
CPU PCH CPU PCH
58 7 52.9 47.9
Same Finalized Design
HVM Air Cooled Thermal
Tool for 65 W also meets
the requirements
Lowest Temp of CPU (TDP=26.8 W) and PCH (TDP = 3.2 W)
BiTS 2017 Poster Session
Burn-in & Test Strategies Workshop
www.bitsworkshop.org March 5-8, 2017
BiTS 2017 3
New HVM ACTT meets all the design requirements removing the liquid detection, harness management issues and lab infrastructure needs
• Reduces the cost by 80% compared to the existing liquid cooled thermal tools
• Next step is to collect the field testing data at HVM
Air Cooled Thermal Tool for System Level High Volume Manufacturing Testing
74.9 mm Gimbaling Mechanism for HVM Automation Environment
Active HS design
New Pedestal Kit design
Actual Prototypes of HVM Client ACTT Received, Functional Testing and Characterization Complete
Uniform TDP (W) Tcp (°C)
CPU PCH CPU PCH
26.8 3.2 15.4 13.7
58 7 49.3 45.3
Finalized Mechanical Design and Actual Prototype
Performance of HVM ACTT latest design w/ updated cold
plate/pedestal and all TIM layers w/ 30 x 30 x 15 mm fan
w/pedestal
Summary