manufacturer of chemical earthing & lightning protection...
TRANSCRIPT
Manufacturer of Chemical Earthing & Lightning Protection System
Earthing is essential in any electrical installation to provide safety. The conventional GI pipe earthing system
employing charcoal & salt are provided for various applications as per IS: 3043. Corrosion of metallic parts is
comparatively fast besides maintenance by way of watering of earth pits and chiselling of corrosion prone
parts & their replacement require monitoring which makes earthing a tough job so to make the earthing job
easy maintenance free chemical earthing are introduced which provides long lasting earthing system.
INTRODCUTION
EARTHCARE TECHNOLOGIES EARTHING ELECTRODES
EARTHING IN MODERN ERA
Solid Rod Type of Earthing (Copper Bonded / Pure Copper)
The Strip In Pipe design incorporates the use of strip inside the pipes joined together for enhancing the
service life and performance of the overall earthing system. The cavity in‐between the electrodes is filled
with crystalline conductive compounds ECGIM Fill for current dissipation and anti corrosive properties.
As per the variegated requirements of our clients, we are offering a broad collection of Solid Rod Type of Earthing. The offered Solid Rod Type of Earthing is integrated in our working unit by utilizing best quality of material with the aid of innovative technology.
PRODUCT CODE EARTHCU333 EARTHCU348 EARTHCU363 EARTHCU376
Diameter 33 48 63 76
Wall Thickness 3.2 3.2 3.6 3.6
Coating Copper Copper Copper Copper
Coating Thickness 250 μ (avg) 250 μ (avg) 250 μ (avg) 250 μ (avg)
Cross Section Area 332 mm² 482.55 mm² 712.5 mm² 860 mm²
Current Rating 8.5 kA Peak 32.5 kA Peak 51.5 kA Peak 76.5 kA Peak
PRODUCT CODE EARTHCR14 EARTHCR17 EARTHCR19 EARTHCR25 EARTHCR32 EARTHCR38 EARTHCR45
Diameter 14 17 19 25 32 38 45
Coating Copper Copper Copper Copper Copper Copper Copper
Coating Thickness 250 μ (avg) 250 μ (avg) 250 μ (avg) 250 μ (avg) 250 μ (avg) 250 μ (avg) 250 μ (avg)
Cross Section Area 153.93 mm² 226.98 mm² 283.53 mm² 490.87 mm² 804.25 mm² 1134 mm² 1590.43 mm²
Current Rating 7 kA Peak 8.5 kA Peak 11 kA Peak 16.5 kA Peak 28 kA Peak 35 kA Peak 42 kA Peak
Strip- In- Pipe Technology (GI/ Copper bonded)
TECHNOLOGY
RECOMMENDATION OF INSTALLTION OF EARTHIN AS PER IS:3043
Installations / 3 Phase Short - Circuit
Current ( Isc Capacity)
IR Value
RequiredSoil Type/ Resistivity Earth System
Normal Soil/ up to 50 ohm-meter Single Electrode
Sandy Soil/ between 50 to 2000 ohm- meter Single Electrode
Rocky Soil/ More than 2000 ohm- meter Multiple Electrodes
Normal Soil/ up to 50 ohm-meter Single Electrode
Sandy Soil/ between 50 to 2000 ohm- meter Multiple Electrodes
Rocky Soil/ More than 2000 ohm- meter Multiple Electrodes
Normal Soil/ up to 50 ohm-meter Single Electrode
Sandy Soil/ between 50 to 2000 ohm- meter Multiple Electrodes
Rocky Soil/ More than 2000 ohm- meter Multiple Electrodes
Normal Soil/ up to 50 ohm-meter Single Electrode
Sandy Soil/ between 50 to 2000 ohm- meter Multiple Electrodes
Rocky Soil/ More than 2000 ohm- meter Multiple Electrodes
Normal Soil/ up to 50 ohm-meter Single Electrode
Sandy Soil/ between 50 to 2000 ohm- meter Multiple Electrodes
Rocky Soil/ More than 2000 ohm- meter Multiple Electrodes
LA, High current Equipment./ 50kAless than 1
ohm
PRS, UTS, RTUs, Data processing centre
etc./5KA
less than 0.5
ohm
House hold earthing/3kA 8 ohm
Commercial premises,Office / 5kA 2 ohm
Transformers, substationearthing, LT line
equipment/ 15kA
less than 1
ohm
NOTES........................................................................................................................................................
....................................................................................................................................................................
....................................................................................................................................................................
....................................................................................................................................................................
....................................................................................................................................................................
....................................................................................................................................................................
....................................................................................................................................................................
INSTALLTION METHOD
The soil in different parts of the world is different and so BFC
is required to give the earth electrode stable surroundings
for functioning.
The Back Fill Compounds are ground enhancing
compounds which are added (mixed with soil) around the
electrode in the earth pit .Their basic properties help in
reducing soil resistivity and improve electrical conductivity
of the earthing system while retaining moisture.
Benefits of Earthcare Grounding Compound
1. Easily forms a homogeneous mixture with water.
2. High moisture retaining capacity.
3. Requires very less time for settling down and getting in
tune with any kind of soil.
4. No need of mixing salt or charcoal with it.
5. Prevents the electrode from corroding as it forms a
protective covering around the earthing electrode.
It is very important that the Earthing System is installed correctly for the system to work at its full efficiency.
Upon proper installation, the system will give very good (desired resistance value) compare to conventional
system of earthing. It will require no maintenance under normal soil conditions except the normal watering
of pits during hot summer seasons. The standard installation method description is packed with every
electrode manufactured by us.
Note: Since there exist varying types of soil & environment conditions around the world, the best resistance
values of an earthing system vary.
Normal Soil
Caution: Avoid excess watering and don’t hammer the electrode.
For instructions on installation methods for other soil types and corresponding BFCs, kindly contact us on
[email protected] or call +91 9825039993/9227511320
· Make a bore of 8” to 10” in dia up to the electrode length of 2/3 meters.
· Fill the bottom 4” of the bore with the supplied BFC (Electrodite).
· Vertically place the electrode in the centre of the pit.
· Fill the cavity around the electrode with the BFC (Electrodite).
· Ensure there are no air gaps in the BFC Filled cavity region.
· Now pour sufficient water into the earth pit until the BFC takes the form of a paste/ mud. Allow
the pit to absorb the water and settle.
· Test the earth pit and make the required connections to the electrical service box.
EARTHCARE GROUNDING COMPOUND
dftrydrft dftrydrft
1:1
NOTE:-
TM
MODEL NO. A B C D E F G H
ECT 33 33 6 25 8 100 40 8 35ECT 48 48 6 32 10 100 40 10 35ECT 60 60 6 50 13 100 40 13 35ECT 76 76 10 50 13 100 40 13 35
150-250Pit Size
Earthcare Grounding Compound(Mixed with Soil)
Ground Level
Inspection Box
Electrode
75 mm Earthing Cable
A
PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCTPR
OD
UC
ED B
Y A
N A
UTO
DES
K E
DU
CA
TIO
NA
L PR
OD
UC
TPRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT
PRO
DU
CED
BY A
N A
UTO
DESK
EDU
CA
TION
AL PR
OD
UC
T