manual motor puerta corredera

4
IP2006 rev. 2008-12-18 CROSS3E/5EH/7EH - 73R QUICK REFERENCE 1. ELECTRICAL CONNECTIONS FOR STANDARD INSTALLATION Before installing the product, carefully read the instructions. XEL5 XEL2 TX XEL2 RX 01 4x0,5 mm² 3x1,5 mm² ANT 4x0,5 mm² 4x0,5 mm² 01 C NO NC Power supply RG58 (max 10 m) 14 0 2x1,5 mm² CROSS3E CROSS5EH CROSS7EH 73R 14 C NO 13 12 0 11 1 1 5 6 8 9 2041 GOL4-GOL4C LAMPH F1 L N

Upload: jmghera

Post on 22-Mar-2016

303 views

Category:

Documents


12 download

DESCRIPTION

Manual de un motor puerta corredera

TRANSCRIPT

Page 1: Manual motor puerta corredera

IP2006 rev. 2008-12-18

CROSS3E/5EH/7EH - 73R QUICK REFERENCE

1. E

LEC

TRIC

AL

CO

NN

ECTI

ON

S FO

R S

TAN

DA

RD

INST

ALL

ATIO

N

Bef

ore

inst

allin

g th

e pr

oduc

t, ca

refu

lly re

ad th

e in

stru

ctio

ns.

XEL5

XEL2

TXXE

L2R

X

01

4x0,5 mm²

3x1,5 mm²

AN

T

4x0,5 mm²

4x0,5 mm²

01

CNO NC

Pow

er s

uppl

y

RG58 (max 10 m)

140 2x1,5 mm²

CRO

SS3E

CRO

SS5E

HCR

OSS

7EH

73R

14C

NO13

120

111

15

68

920

41

GO

L4-G

OL4

C

LAM

PH

F1

LN

Page 2: Manual motor puerta corredera

2CROSS3E/5EH/7EH-73R QUICK REFERENCE - IP2006

2. LIMIT SWITCHES CONNECTION FOR CROSS5EH - CROSS7EH ONLY (OPTIONAL)

Adjust the limit switch brackets! Adjust the limit switch brackets!

FCMCRFCMCR

12 011

Remove the bridges!

Connect the limit switches!

12 011

Page 3: Manual motor puerta corredera

3 CROSS3E/5EH/7EH-73R QUICK REFERENCE - IP2006

3.1 USAGE WITHOUT LIMIT SWITCHES

3.2 USAGE WITH STOP LIMIT SWITCHES (OPTIONAL)

DIP2=OFF

AOpening limit switch setting

CClosing limit switch setting

- + VA opening speed setting

- + VC closing speed setting

Slow down speed

DIP2=ON

AOpening limit switch setting

CClosing limit switch setting

- + VA opening speed setting

- + VC closing speed setting

Slow down speed

DIP2=OFF

- + VA opening speed setting

- + VC closing speed setting

Slow down speed

OPENING CYCLE

CLOSING CYCLE

CLOSINGMECHANICAL STOP

OPENINGMECHANICAL STOP

OPENING CYCLE

OPENING CYCLE

CLOSING CYCLE

CLOSING CYCLE

A

AC

C

OPENING MECHANICAL STOP

CLOSINGMECHANICAL STOP

CLOSING CYCLE

OPENINGCYCLE

DIP2=ON

- + VA opening speed setting

- + VC closing speed setting

Slow down speed

Page 4: Manual motor puerta corredera

4CROSS3E/5EH/7EH-73R QUICK REFERENCE - IP2006

5. RADIO ENABLING

4. 73R STANDARD SETTING

i For different setting and further information consult the CROSS3E, CROSS5EH, CROSS7EH automation instruction manual, the 73R control panel instruction manual and BIXLR22 radio instruction manual.

DITEC S.p.A.Via Mons. Banfi, 3 - 21042 Caronno Pertusella (VA) - ITALYTel. +39 02 963911 - Fax +39 02 9650314 www.ditec.it - [email protected]

6. AUTOMATIC CLOSING SETTING

- +

TC time settingDISABLED!

MAX

- +

TC time setting ENABLED!

MIN=0 s MAX

120 s

MIN=0 s MAX

120 s

VA VC TC R1

6 4

20 2

NIO1 2 3 4 5

C NO 0 1 1 5 6 8 9 20 4114 13 12 11

SO JR4

JR3

ON

OFF

DIP1 = ON

DIP2 = ON

OPENING RADIO MODE

LEFT OPENING

DIP2 = OFF RIGHT OPENING

DIP1 = OFFSTEP BY STEP RADIO MODE

GOL4-GOL4C

Wait for 10 s

SIG

Push PRG

Led SIG comes on

Push CH

SIG

Led SIG flashes 3 times

1° 2°

SIG

NIO

PRG

JR3