manual may30 a202cr & a204crlogenex.com/oldsite/downloads/discontinued/a200... · when some...

24
6A-7500 Martin Grove Rd. Woodbridge, ON. Canada L4L 8S9 Toll Free: 1.888.790.5900 E-mail: [email protected] Don't open your door to the unknown TeleDoorBell TM Installation & Programming A202CR & A204CR “X” & “S” Series Audio Audio / Video (Day/Night Camera) TeleDoorBell Audio (Stainless Steel)

Upload: others

Post on 31-Jul-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Manual May30 A202CR & A204CRlogenex.com/oldsite/downloads/discontinued/A200... · when some service or repair is required. Opening or removing covers may expose you to dangerous voltages

6A-7500 Martin Grove Rd. Woodbridge, ON. Canada L4L 8S9 Toll Free: 1.888.790.5900 E-mail: [email protected]

Don't open your door to the unknownTeleDoorBell TM

Installation & Programming

A202CR & A204CR“X” & “S” Series

AudioAudio / Video

(Day/Night Camera)

TeleDoorBell

Audio (Stainless Steel)

Page 2: Manual May30 A202CR & A204CRlogenex.com/oldsite/downloads/discontinued/A200... · when some service or repair is required. Opening or removing covers may expose you to dangerous voltages

Table of Contents

Important Notes and Safety Instructions ........................................... Pg 1“X” Series Specifications .............. ............................................................. Pg 2“S” Series Specifications............................................................................. Pg 3Features and Parts Listing.......................................................................... Pg 4Controller Anatomy .................................................................................. Pg 5“X” Series Door Station Wiring.................................................................... Pg 6“S” Series Door Station Wiring.................................................................... Pg 7Controller Wiring Diagram .................................................................... Pg 8TBG-1 Installation Diagram........................................................................ Pg 9DSL Installation Diagram ..........................................................................Pg 10KSU/PBX Installation Diagram.... ............................................................ Pg 11M203HIFI Installation Diagram... ............................................................. Pg 12“X” Series Programming Guide ....................................................... Pg 13-16“HI-FI” Series User/Programming Guide ..................................................Pg 17TroubleShooting Guide....................................................................... Pg 18-19Warranty Information.......................................................................... Pg 20-21

1) Certain cordless phones may not ring or ring properly when Door Station Speaker Button is pressed. Phone will still be operationaland all functions are still active and accessible.

2) An average of (6) six phones limit will apply for having connected phones ring. Exceeding this limit may result in some phone(s) notringing. (Results and phone limitations may vary depending on types of phones and the loads (LN#) they present to the overallsystem).

NOTE:

3) Remote Call Answer may not be compatible with various types of add-on phone features such as Ident-A-Call, Call Display LongDistance ringing or any other feature(s) which will change or produce a different ringing pattern of an incoming call.

4) System may not be compatible with various voice-mails including cell phones when enabling the Door Station Call Forwardingfeature.p (Results and features may vary with your local service provider / supplier).

5) If a Logenex DSL 3-Port High-Speed Filter (LX-DSL3F) is installed and the user places a phone caller ON-HOLD using thecommand to communicate to a Visitor at the Door Station, a low level cross-talk may be heard by the user when communicating tothe Visitor at Door Station.

6) Some Phone Service Providers, phone features and/or command functions may not be compatible with the product(s)

��

TeleDoorBell .

The Load Number (LN) assigned to each terminal device denotes the percentage of the total load to beconnected to a telephone loop which is used by the device to prevent overloading.

COMPATIBILITY ISSUES

Page 3: Manual May30 A202CR & A204CRlogenex.com/oldsite/downloads/discontinued/A200... · when some service or repair is required. Opening or removing covers may expose you to dangerous voltages

Page 1

Safety instructions and Guildlines

A factory default on the unit must be performed prior to initialuse. SEE PAGE 16

PLEASE VERIFY THAT YOUR TELEPHONE SYSTEM COMPLIES WITH A TYPICAL 95VOLTS RMS @ 20 Hz RING. IF INSTALLED WITHOUT VERIFICATION

TELEPHONE EQUIPMEN, THIS PRODUCT

MAY CAUSE DAMAGE TO T. IF YOUR TELEPHONE SYSTEMDOES NOT MEET THE ABOVE REQUIREMENTS PLEASE CONTACT LOGENEX

INNOVATIONS INC. FOR FURTHER INFORMATION.

NOTICE

SAFETY INSTRUCTIONS

When using your telephone equipment, basic safety precautions should always be followed to reduce the risk offire, electric shock and injury to persons, including the following:

1. Read and understand all instructions.2. Follow all warnings and instructions marked on the product.3. Unplug this product from the wall outlet before cleaning. Do not use liquid cleaners or aerosol cleaners. Use

a damp cloth for cleaning.4. Do not use or expose this product to direct water contact: ie: near a bathtub, wash bowl, kitchen sink, laundry

tub, in a wet basement, or near a swimming pool.5. Dropping this product may result in serious damage to the product.6. This product should never be operated near or over a radiator or heat register. This product should not be

placed in a built-in installation unless proper ventilation is provided.7. This product should be operated only from the type of power source indicated on the marking label. If you

are not sure of power supply to your home, consult your dealer or local Power Company.8. Do not allow anything to rest on the power cord. Do not locate this product where the cord will be abused by

persons walking on it.9. Do not overload wall outlets and extension cords as this can result in risk of fire or electric shock.10. Never push objects of any kind into this product through cabinet slots as they may touch dangerous voltage

points or short out parts that could result in a risk of fire or electric shock. Never spill liquid of any kind on theproduct.

11. To reduce the risk of electric shock, do not dissemble this product, but take it to qualified service technicianwhen some service or repair is required. Opening or removing covers may expose you to dangerousvoltages or other risks. Incorrect re-assembly can cause electric shock when the appliance is subsequentlyused.

12. Unplug this product from the wall outlet and refer servicing to a qualified service personnel under thefollowing conditions:

* When the power supply cord or plug is damaged or frayed.* If liquid has been spilled into the product.* If the control unit has been exposed to rain or water.* If the product does not operate normally by following the instructions. Adjust only those controls that

are covered by the operating instructions because improper adjustment of other controls may result indamage and will require extensive work by a qualified technician to restore to normal operation.

* If the product has been dropped or the housing has been damaged.* If the product exhibits a distinct change in performance.

13. Avoid using a telephone (other than cordless type) during an electrical storm. There may be a remote risk ofelectric shock from lightning.

14. Do not use the telephone to report a gas leak near the source of the leak.15. This device may cause harmful interference.16. This device may be susceptible to any interference including interference that may cause undesired

operation.Complies with Part 68, FCC Rules FCC REG NO. 5ERCAN-31264-OT-N REN: 0.5B

Page 4: Manual May30 A202CR & A204CRlogenex.com/oldsite/downloads/discontinued/A200... · when some service or repair is required. Opening or removing covers may expose you to dangerous voltages

Page 2

AD

10

2

X=

Sta

ndard

Unit

(Satin N

ickel)

VC

= D

ay/N

ight cam

era

with ir

(n/a

in s

tain

less s

teel)

Mo

de

l N

um

be

r Id

en

tifica

tio

n (

KIT

)A

CR

2=

2 D

oor

4=

4 D

oor

X=

Sta

ndard

Unit

(Satin N

ickel)

VC

= D

ay/N

ight cam

era

with ir

(n/a

in s

tain

less s

teel)

Mo

de

l N

um

be

r Id

en

tifica

tio

n(I

ND

IVID

UA

LD

OO

RS

TA

TIO

N)

20

-

-

Page 5: Manual May30 A202CR & A204CRlogenex.com/oldsite/downloads/discontinued/A200... · when some service or repair is required. Opening or removing covers may expose you to dangerous voltages

AD

102

S=

(S

urf

ace

Mo

un

tS

tain

less S

tee

l)

VC

= D

ay/N

igh

t ca

me

ra w

ith

ir

Model N

um

ber

Identification (

KIT

)A

CR

2=

2 D

oor

4=

4 D

oor

Model N

um

ber

Identification

(IN

DIV

IDU

AL

DO

OR

STA

TIO

N)

20

-

-

S

F=

Flu

sh

Mo

un

t

VC

= D

ay/N

igh

t ca

me

ra w

ith

ir

S

S

S=

(S

urf

ace

Mo

un

tS

tain

less S

tee

l)

F=

Flu

sh

Mo

un

t

Page 3

Page 6: Manual May30 A202CR & A204CRlogenex.com/oldsite/downloads/discontinued/A200... · when some service or repair is required. Opening or removing covers may expose you to dangerous voltages

Features and Parts Listings

D.O.C. NOTICE:The Canadian Department of Communications label identifies certified equipment. The certification means that the equipmentmeets certain telecommunications network protective, operational and safety requirements. The Department does not guaranteethe equipment will operate to the user’s satisfaction.Before installing this equipment, user should ensure that it is permissible to connect to the facilities of the localtelecommunications company. The equipment must also be installed using an acceptable method of connection. User shouldensure that the telephone lines and metallic water pipe system (if present) are electrically grounded.

The TeleDoorBell is a telephone based doorbell system that provides the system user with the capability of communicating with adoor speaker from any installed telephone set, including cordless. Unmatched in convenience, this unique new product providesthe following features:

* System will work as a replacement or in parallel with any standard doorbell. (see page 7)* Provides high-quality audio conversation capability with any connected Door Station Speaker.* Unique telephone ringing when Door Station Speaker button pressed. (see page 8)* Allows user to activate a Door Station Speaker by entering a unique touch-tone code from any telephone. (see page 13)* Will provide call restriction at the discretion of the owner. (see page 8)* Relays available for doorbell chime activation or any other devices (24Volts 1Amp max rating).* Door Station Speaker has LED illuminated Button.* The system gives a user two minutes to access the Door Station Speaker once the speaker button has been pressed.* Door Station Speaker Call Waiting function which allows the user to switch between a Visitor and an existing Phone Caller.

The user can press on a touch-tone telephone to put the telephone call on hold and connect to the Door StationSpeaker. Pressing again will return the User back to existing Caller. Note: this can only be used once the Door StationSpeaker button is pressed. A second option for switching from Caller to Visitor is by hanging up on the existing telephonecall and then picking up the handset (within the allowed 2 minutes) at which point you will be automatically connected to theDoor Station Speaker.(Beyond the two minute window you will have to manually activate the Door Station Speaker ( (Door Station Speaker#1) ... (Door Station Speaker #4)(Note: Speaker must be connected to a the port which you are trying to communicate with.)

* Relay closure activated by DTMF digit (Normally Open Dry Contact Operation):Each RELAY can be triggered for either LATCHING MODE or TIMER MODE (01 - 98 seconds). Default setting is

seconds.Timer Relays

(Relay #1), (Relay #2), (Relay #3 when applicable), (Relay #4 when applicable),* Will activate the relay which is connected to the door station which initiated communication.

Latching Relays(Relay #1), (Relay #2), (Relay #3 when applicable), (Relay #4 when applicable),

To De-activate latched relays(Relay #1), (Relay #2), (Relay #3 when applicable), (Relay #4 when applicable),

* Call Restriction blocking (up 10 programmable phone number restrictions) [30 digits maximum / phone number].* "Door Station Caller ID Display" feature is available when ENABLED and to be used with Call Display Phones only. An

identification information is transmitted by the controller to the display phone when the Door Station Speaker Button ispressed. Display will show (DOOR 1 ... DOOR 4) which ever speaker port was pressed

* 4-Digit passcode protection for programming system.* Unit contains E Memory Technology for retaining stored memory data in the event of a temporary power failure.

The TeleDoorBell “X Series” system is shipped from the factory with the following components:* TeleDoorBell “X Series” control unit* One (1) Door Station Speaker* CSA/UL approved class 2 power supply, input 120VAC, 60Hz, output 16VAC 250 mA.* One (1) RJ31X/CA 38A Jack.* Two (2) modular RJ-11 Male open-ended patch cord. Used to splice and connect Door Station Speaker and Relay, and

built in door chime relay.* RJ-45 8 pin male to male modular patch cord 36" long.* Two (2) #8 screws 1" for mounting Door Station Speaker* Two (2) plastic anchors for mounting Door Station Speaker* One (1) #6 wood screw 2" for mounting Controller* Dimensions: Controller (17cmX17cmX4cm) Door-speaker (17cmX11cmX3.3cm)

��

��

���

���

��� ��� ��� ���

���

�� �� �� ��

�� �� �� ��

6

Parts list

2

Features and Instructions Overview

Page 4

Page 7: Manual May30 A202CR & A204CRlogenex.com/oldsite/downloads/discontinued/A200... · when some service or repair is required. Opening or removing covers may expose you to dangerous voltages

Controller Anatomy

Page 5

Fig 1

Spk/Rly#1Spk/Rly#2Spk/Rly#3Spk/Rly#4 Tele Line In & Out Power Plug

A202CR & A204CR

26 5 4 37 1[1] Power Supply Jack

.

[2] Power Status LED

NOTE: When unit is first powered up the LED will remain solid for 5 seconds and will begin to flash slowlywhen ready. When the TeleDoorBell is in use the LED will flash rapidly for the duration of connectivity.

[3] Telephone Line In & Out Jack

[4] Speaker / Relay Port #1

(RELAY #1)

[5] Speaker / Relay Port #2

(RELAY #2)

[6] Speaker / Relay Port #3

(RELAY #3)

[7] Speaker / Relay Port #4

(RELAY #4)

This jack is the connecting point for AC power supply to the unit. The supply is typically 16 VAC at a minimum of 250mA

When "FLASHING" this LED indicates the presence of power to the unit and that the controller is operating properly.When LED is "OFF" it indicates the absence of power to the unit. When the LED is “ON” (not flashing) this indicates thatthe unit is locked up and will need to be reset by unplugging the power for 60 seconds and then powering back up.

This jack provides connection to the incoming telephone line on the inner pair and connection to telephone(s) on theouter pair.

This port jack enables a connection to a for communication while also providing (1) dry contactrelay for automated control capability.

This port jack enables a connection to a for communication while also providing (1) drycontact relay for automated control capability.

This port jack enables a connection to a for communications while also providing (1) dry contactrelay for automated control capability.

(see page9)

This port jack enables a connection to a for communications while also providing (1) relay drycontact point for automated control capability.

To complete the installation the installer must supply/install the following:* RJ31X CA38A . (This is recommended in the event that the controller needs to be disconnected. This willprovide a bypass capability whereby the telephone line continues to work if the unit needs to be removedfrom the telephone line. Note: If installation is done at a location that has an existing alarm jack (RJ31X CA38A)then ensure that the alarm is installed before the TeleDoorBell RJ31X CA38A jack. Otherwise, the alarm systemmay not have disconnect priority.

Installation of the system requires that the installer install a 2-conductor wire 22 AWG (Max Length 1000’), from thelocation of the door speaker unit to the location of the system control unit or a CAT-5 wire (Max Length 250’) if you areinstalling a system with Video/Audio features.

It is recommended that the system control unit be installed near the point-of-entry of the customer's main telephone line.

Door Station Speaker

“Door Station Speaker”

Door Station Speaker

**This RELAY is PRESET [DISABLED] to use RELAY#3 for the DOORBELL function, you must [ENABLE] theDOORBELL Function in the programming. This Relay can be changed back to the standard control capability.Doorbell function is applicable for both A202 & A204 models

“Door Station Speaker”

TeleDoorBell

Installation Instructions

and/or (supplied)

and/or

and/or

NOTE: To achieve 1000 ft range with video, you must use COAX Cable in-place ofthe 2 conductor required for the video signal.

IMPORTANT NOTICE:For added protection we strongly recommend you use surge protectors on both your power supply and on the C/O line (phoneline) to protect against lightning and other energy surges. This precaution may be extremely important in rural areas.

Model A204 ONLY

Model A204 ONLY

Page 8: Manual May30 A202CR & A204CRlogenex.com/oldsite/downloads/discontinued/A200... · when some service or repair is required. Opening or removing covers may expose you to dangerous voltages

Page 6

“X” Audio & Video Installation

Red = Audio Input +

Green = Audio Input -

LEFT Side of Speaker RIGHT Side of Speaker

Installation

1) Separate back housing fromfront housing. Step 1 Removeset screw Step 2: swing bottomof housing out. Step 3: pull backhousing out from top hinge. SeeFig-2

2) Knock out wiring hole. Feedwire through opening

See Fig-3

Note: We recommend that youuse silicon sealer to protect thewiring around the hole

3) Mount back box using desiredmounting hole knock outs andsecure firmly.

See Fig-3

4) Connect the two wires to thewiring post on the inside of DoorSpeaker. See Fig 4 and Fig 4.1(Video Model: See Fig 4.2 forvideo connection)

5) Mount front housing of DoorSpeaker on the secured backbox. Secure front housing usingbottom set screw. See Fig-2.1Steps 1, 2 & 3

12Volt +

12Volt -Common Ground

Video

Red

Green

Fig 4

VideoPowerSupply(supplied withdoorstation)

12V DCOutput

Ring On/Off Relay Contacts Door Spkr 2 Door Spkr 1 Tele Line In & Out Power Plug

RJ11 Modular Wire(Supplied with controller)

To Speaker JackTeleDoorBell

RCA Patch Cord(supplied with Speaker)

To Video input or Cable Modulator, DVR,Monitor, or Television

Common(GROUND)

12VDC +

Video +

Video -

Wire can vary from standard quad, CAT-5 and/or RG6 for the Video Signal. Speaker distance from controller is a factor andshould be considered.

VIDEO NOTE: Wire recommended formost applications under 100 ft is CAT-5.RG-6 Wire for video signal should be usedfor longer distances.

Fig 3

Wiring Hole

Fig 2 (Side View)

1

2

VOLUME

MIN MAX

IN-

IN+

VOLUME

MIN MAX

+A

UD

IO

+V

IDE

O

CO

MM

ON

GN

D-

+12V

VIDEO

VideoOut

AudioOut

IN+

IN-

Audio

AudioFig 4.1Fig 4.2 Inside of Door SpeakerVideo and Audio terminals

Volume Control may need to beadjusted to accommodate fordifferent acoustic environments.

+A

UD

IO

+V

IDE

O

CO

MM

ON

GN

D-

+12V

VIDEO

VIDEO

AUDIO

12VDC -

Mounting Holes

Mounting Holes

PreMountingBoxInstall

Fig 2.1 (Side View)

PostMountingBack BoxInstall

1

2

3Set Screw

Page 9: Manual May30 A202CR & A204CRlogenex.com/oldsite/downloads/discontinued/A200... · when some service or repair is required. Opening or removing covers may expose you to dangerous voltages

Page 7

“S” Series Audio & Video Installation

Installation

1) Separate backhousing fromfront housing.Step 1: swingtop of housingout. Step 2: pullunit out of backbox.

2) Mount backbox eithersurface or

flush mount.Run wirethough wiringhole located inthe middle ofthe back box.Secure firmly.

Note: We recommend thatyou use silicone sealer toprotect the wiring around thehole

3) Connect the two wires tothe wiring post on the insideof Door Speaker.

4) Mount the unit back into theback box.

5) Secure stainless steel frontface plate with the two(2) hexset screw using the hex key.

6)Connect 12 volt incomingpower from 12 volttransformerinto the terminals label +12Vand GND.

7) Connect the video output toyour wires via the terminalslabeled +VID and -VID.

See Fig-2

See Fig-3

See Fig-4

See Fig-5

See Fig-6

VIDEO MODEL SETUP

(supplied in kit)

To Speaker TerminalTeleDoorBell

Fig 3

Fig 2 (Side View)

Fig 2 (Side view)

Wiring Hole

TeleDoorBell

Fig 5

Step1

Mounting Holes

+IN

-IN

VO

LU

ME

MIN

MAX

CO

MM

Audio Connection

IN +

IN -Green

Red

Fig 4

NOTICEVolume Control may need to be

adjusted to accommodate fordifferent acoustic environments.

TeleDoorBell

TeleDoorBell

Flush Mount Surface Mount

Step4

Fig 2.1 (Side view)

12V

GND

+VID-VID

+IN

-IN

PO

WE

RV

IDE

O

VO

LU

ME

MIN

MAX

CO

MM

12 Volt +

12 Volt -

Video +

Video -

NOTICEVolume Control may need to be

adjusted to accommodate fordifferent acoustic environments.

Fig 6 Video Connection(applicable to -SVC and -SFVC model only)

Spk/Rly#1Spk/Rly#2Spk/Rly#3Spk/Rly#4 Tele Line In & Out Power Plug

TeleDoorBell “X Series”

TeleDoorBell

12VDCOutput

To Video input or Cable Modulator, DVR,Monitor, or Television

NOTICEThis Video setup is applicable

for video models only.-SVC and SFVC

Page 10: Manual May30 A202CR & A204CRlogenex.com/oldsite/downloads/discontinued/A200... · when some service or repair is required. Opening or removing covers may expose you to dangerous voltages

Controller Wiring Diagram

Page 8

ExistingdoorbellTransformer

120V ACAlready connected

OUT

OUT

IN

IN

Existingdoorbell switch(to be removed)

TransformerFront Door

Door Bell

Disconnectswitch and connectwires together

Wire is reconnectedto the TeleDoorBell

Doorbell rewiring section

Red

Grey Red

Yellow

Yellow

Black

Black

Green

Brown Green

RJ31X(CA38A)Data Jack

16V ACOutput

ToPhone

TeleDoorBell TM Figure 5

Spk/Rly#1Spk/Rly#2Spk/Rly#3Spk/Rly#4 Tele Line In & Out Power Plug

A202CR & A204CR

Relay #1connection

Relay #3connection

���(to activate)

���(to activate or will automatically

activates if configured as theDoorBell function)

Applicablefor bothA202 &A204Models

NOTICE

See Page 6 & 7 forDoor Station Connectivity.

OUT

OUT

IN

IN

RJ31X(CA38A)

Alarm Jack

LINE from phone provider,VOIP Modem or Cable Modem

Alarm jackconnection

only if alarmmonitored

RELAY SPECIFICATIONS:Normally Open Relays are rated for up to:

(1 Amps at 12-24 AC or DC Volts).

(1) Door station Included withany kit purchase

Page 11: Manual May30 A202CR & A204CRlogenex.com/oldsite/downloads/discontinued/A200... · when some service or repair is required. Opening or removing covers may expose you to dangerous voltages

TBG-1 Installation Diagram

Page 9

A202C

R &

A204C

R

RJ1

1 M

odula

rW

ire

(Suppli

ed w

ith u

nit

)

16V

AC

Ou

tpu

t

To te

leph

one

orK

SU

/PB

X p

hone

sys

tem

Exi

stin

g P

ower

Sup

ply

supp

lied

with

Tele

Doo

rBel

lC

ontr

olle

r/ s

peak

erki

t.

Spl

ice

the

pow

erca

bles

and

split

them

betw

een

the

Con

trol

ler

&T

BG

-1

RJ11

RJ4

5

Re

ve

rse

Vie

w

16

VA

C

Fro

nt

Vie

wT

BG

-1F

ron

t&

Rea

rV

iew

Sp

k/R

ly#4

Sp

k/R

ly#3

Sp

k/R

ly#2

Sp

k/R

ly#1

Tele

Lin

e In

&O

ut

Po

wer

Plu

g

Page 12: Manual May30 A202CR & A204CRlogenex.com/oldsite/downloads/discontinued/A200... · when some service or repair is required. Opening or removing covers may expose you to dangerous voltages

DSL Installation Diagram

Page 10

LX-DSL3F 3-PORT FILTER Installation Diagram

Alarm Panel

A202CR & A204CR

OUT

OUT

IN

IN

RJ31X(CA38A)Data Jack

StandardDSL Filter

StandardDSL Filter

High-SpeedInternet Modem(supplied by internet provider)

Brown

Red

Red

Red

Grey

Green

Green

Green

STRUCTURALPANEL

OR

This (TEST / 3rd Output) PORTcan be used for:

1) Test phone (for isolatingand troubleshooting problems)2) For a KSU phone system

configuration3) To all the premise phones

which do not require highspeed internet connection

which will eliminate theneed to have DSL filters

at every phone jack

RJ45 RJ45 RJ45

PHONESYSTEM

KSU

Note: This (DSL 3-PORT FILTER) may cause ato occur. This may result in

the caller to partially hear the low level conversationbetween the home owner and the visitor at the door station

when the caller is placed on hold using theON-HOLD command.

LOW-LEVEL AUDIO CROSS-TALK

ONLY ��

(see also Terms & Conditions on the back for complete Warranty and Issues to avoid)

LINE from phone provider,VOIP Modem or Cable Modem

Page 13: Manual May30 A202CR & A204CRlogenex.com/oldsite/downloads/discontinued/A200... · when some service or repair is required. Opening or removing covers may expose you to dangerous voltages

KSU/PBX Installation Diagram

Page 11

KSU

Phone System

KSU

Phone System

Using one of the existing lines Using the and anavailble C/O port

TeleDoorBell

Eg:3-Linesystem

Eg:3-LinesystemLine 1

Line 1

Line 2

Line 2

Line 3

Line 3

Line 4TeleDoorBell

Line1 / Line2 / Line 3 with TeleDoorBell

Line1 / Line2 / Line 3 / Line4 TeleDoorBell

* Note: In this installation the willfunction properly with the exception of being ableto monitor the door speaker. The speaker willonly be active when the button is pressed. To beable to monitor your door speaker any time youwill require a TBG-1 accessory module. (Page 9)

TeleDoorBell

OUT OUT

IN IN

RJ31X(CA38A)Data Jack

(Not supplied)

Tip Ring

Phone System must be programmed for extensions to ring.Consult your KSU/PBX phone system manual for instructions

Black

Green Red

Yellow

Spk/Rly#4 Spk/Relay#3 Spk/Relay#2 Spk/Relay#1 Tele Line In & Out Power Plug

A202CR & A204CR

Spk/Rly#4 Spk/Relay#3 Spk/Relay#2 Spk/Relay#1 Tele Line In & Out Power Plug

A202CR & A204CR

Grey

Red

Brown

Green

PLEASE VERIFY THAT YOUR TELEPHONE SYSTEM COMPLIES WITH A TYPICAL 95VOLTS RMS @ 20 Hz RING. IF INSTALLED WITHOUT VERIFICATION

TELEPHONE EQUIPMEN, THIS PRODUCT

MAY CAUSE DAMAGE TO T. IF YOUR TELEPHONE SYSTEMDOES NOT MEET THE ABOVE REQUIREMENTS PLEASE CONTACT LOGENEX

INNOVATIONS INC. FOR FURTHER INFORMATION.

NOTICE

Page 14: Manual May30 A202CR & A204CRlogenex.com/oldsite/downloads/discontinued/A200... · when some service or repair is required. Opening or removing covers may expose you to dangerous voltages

M203HIFI Installation Diagram

Page 12

M203H

IFI

OU

T

OU

T

ININ

RJ31X

(CA

38A

)D

ata

Jack

RJ4

5 M

odula

rW

ire

(Suppli

ed w

ith

Tel

eDoorB

ell)

To

Ph

on

eJ

ack

s

RJ1

1 M

odula

rW

ire

(Suppli

ed w

ith P

G-1

00)

16

VA

CO

utp

ut

Spk

/Rly

#1S

pk/R

ly#2

Spk

/Rly

#3H

i-Fi O

utpu

tsTe

le L

ine

In &

Out

Pow

er P

lug

A203H

IFI

OU

T

OU

T

ININ

RJ31X

(CA

38

A)

Ala

rmJack

Ala

rm j

ack

connec

tion

only

if a

larm

monit

ore

d

Door

spea

ker

(In

clu

ded

wit

hT

eleD

oorB

ell)

Am

pli

fier

and s

pea

ker

pag

ing s

yst

em(N

ot

Incl

ud

ed)

Pa

gin

g O

pe

rati

on

- P

ick

up

ha

nd

se

t

- P

res

s

- Te

leD

oo

rBe

ll w

ill

ac

tiv

ate

mu

tin

g a

nd

se

nd

pa

ge

an

no

un

cm

en

tto

ne

s.

To P

AG

ING

IN

of

am

pli

fier

syst

em

Audio

Out

Au

dio

OU

T12

Vo

lt/

Co

nta

ct C

losu

re

C.C

. /

12V

Vo

lum

eC

on

tro

lP

ow

erO

NA

ud

ioIN

PO

WE

R

M203H

IFI

Fro

nt

Vie

w

Rea

rV

iew

12 V

olt

Tri

gger

or

Conta

ct C

losu

re

Au

dio

Ou

tC

on

nec

tion

+ -

Op

tio

nal

Au

dio

Ou

t o

n t

he

bac

k an

d f

ron

t**

* O

NLY

US

E O

NE

OU

TP

UT

ON

L Y**

*

��

-+

-+

+-

- Sw

itch

to l

eft

for

Conta

ct C

losu

re.

- Sw

itch

to r

ight

for

12Volt

tri

gger

.

Mu

tin

gC

on

nec

tion

Muti

ng C

onnec

tion O

utp

ut

Muti

ng

Tri

gger

.

Hi-

Fi

Featu

re O

peratio

ns

On

a d

oo

r st

atio

n c

all

the

Tel

eDo

orB

ell

wil

l m

ute

fo

r 1

min

ute

. I

f th

e ca

ll i

san

swer

ed,

the

syst

em w

ill

rem

ain

mu

ted

fo

r th

e d

ura

tio

n o

f th

e ca

ll.T

he

Tel

eDo

orB

ell

wil

l u

n-m

ute

on

ce c

om

mu

nic

atio

n h

as e

nd

ed.

On

an

in

com

ing

cal

l th

eT

eleD

oo

rBel

l w

ill

mu

te o

n t

he

firs

t ri

ng

. If

th

e ca

llre

mai

ns

un

answ

ered

aft

er t

he

thir

d r

ing

th

eT

eleD

oo

rBel

l w

ill

init

iate

aR

ing

-Ov

er-P

age

feat

ure

fo

r th

e re

mai

nd

er o

f th

e ri

ng

cy

cle.

16

VA

CO

utp

ut

Mu

tin

gF

un

cti

on

ON

/O

FF

���

1)

Pic

k u

p p

ho

ne

ha

nd

se

t a

nd

en

ter

pro

gra

mm

ing

2)

En

ter

pro

gra

mm

ing

pa

ssw

ord

(d

efa

ult is

)3

) E

nte

rto

to

gg

le m

utin

g o

n/

off

2 B

ee

ps =

Mu

tin

g o

n3

Be

ep

s =

Mu

tin

g o

ff

��

����

���

(fa

cto

ry d

efa

ult) G

rey

Red

Bro

wn

Gre

en

LIN

E f

rom

ph

on

e p

rovid

er,

VO

IPM

od

em o

rC

ab

le M

od

em

Page 15: Manual May30 A202CR & A204CRlogenex.com/oldsite/downloads/discontinued/A200... · when some service or repair is required. Opening or removing covers may expose you to dangerous voltages

Programming Guide

This feature allows you to change the ringing pattern when a Door Station Speaker is pressed.DISTINCT RING is ideal if you want to distinguish between an incoming phone call and someone atthe Door Station Speaker. A distinct and different ring pattern will be produced for each Door Station.

1) PRESS2) Listen for .

=

��

��

BEEPS

2

(3) BEEPS

( ) BEEPS = The same (6 RING) pattern for all Speaker Door Station Ports

DISTINCT RINGING PATTERN (a different pattern for every Speaker Port) (FACTORY DEFAULT)

NOTE B: y continuing to Press the Command, the system will toggle between the (6-RING DISTINCT RING pattern)./

This feature allows you to activate the Door Station caller ID display function. When the Door StationSpeaker is pressed, a Caller ID transmission is made to any connected CALL DISPLAY stylephones. (eg: DOOR 1 .... DOOR 4).

1) PRESS2) Listen for .

=

���

���

BEEPS

2

(3) BEEPS

( ) BEEPS = Door Station Caller ID is ENABLED [ON]

Door Station Caller ID is DISABLED [OFF]

(FACTORY DEFAULT)

Note: This setting is recommended if Call Display Phones are not used

NOTE B /: y continuing to Press the Command, the system will toggle between Door Station Call Display (ON OFF)

This feature allows you to prohibit or block phone numbers from being dialed.The user has the ability to block specific phone numbers and/or numbers that begin with a particularsequence (eg: or ).��� ��

1) PRESS2) Listen for .

3) SELECT a Memory BIN Number ( )4)

���

����

(2) BEEPS

��

Listen for .(1) BEEP

(2) BEEPS will be heard for acceptance of programming.

Note: Call restriction requires 3 digits minimum. To restrict 1+ long distance number you will have to enter

To block any other one digit number you simply enter plus the one digit starting number. For a 2 digit number

restriction you will enter plus the 2 digits you wish to restrict.

To DELETE a Call Restriction Programmed Number from a Memory Bin you must performs STEPS 1,2,3,4 and 6 (eliminatingSTEP 5). This will remove the restricted number. (3) BEEPS will confirm deleted memory bin. Repeat STEPS 1-6 to re-enablea number restriction.

) Enter the Phone Number to restrict 1

) PRESS to SAVE

5

6

..... 30 (up to 30 Digits) * see note below

PRESS to go into programming mode

**

�� (Listen for (2) Beeps)

MUST BE ENTERED WITHIN 5 SECONDS OF GOING OFFHOOK

ENTER passcode ���� (Listen for (2) Beeps) (Default Passcode)

Page 13

NOTE: When Entering any programming functions, you have up to 30 seconds idle time before the systemwill hang up at which point any programming started will not be saved

Call Restriction Phone Number Programming ���

Ring Pattern Configuration ��

Door Station Caller ID Configuration ���

Continuedon Page-14

Pick up phone handset and listen for dial tone.

Page 16: Manual May30 A202CR & A204CRlogenex.com/oldsite/downloads/discontinued/A200... · when some service or repair is required. Opening or removing covers may expose you to dangerous voltages

Programming System Features [continued]

Programming Guide

This feature allows the user to program Relay #3 to activate the Doorbell Chime when the DoorStation Speaker is pressed. (see page 7)

1) PRESS2) Listen for .

=

=

���

���

BEEPS

(2) BEEPS

(3) BEEPS

Enables RELAY#3 for Doorbell Function activation of a Doorbell Chime or other notification device.

Disables RELAY#3 from activating as a Doorbell Function (FACTORY DEFAULT)

NOTE B /: y continuing to Press the Command, the system will toggle between (ON OFF)

This feature allows you to activate the Remote Dial-up Answering feature. This feature allows theuser to call in to the unit from most outside phone lines (certain conditions may apply) to program oractivate any of the TeleDoorBell’s functions.Note: An Answering Machine (if installed or subscribed though TelCo) should be configured to answer on 4 or more rings and an "ALARMSYSTEM" (if present) must be configured to answer on "ANSWERING MACHINE OVERRIDE [1+1]" MODE

1) PRESSListen for

���

���

2)

=

=

BEEPS.

(2) BEEPS

(3) BEEPS

3+1 RINGING (this means you call in for 3 rings, hang-up wait for 10-15 Seconds (for the unit to ENABLE itself)and then call back. The unit at this point will answer on the first ring).

[OFF] Unit will not answer

(FACTORY DEFAULT)

NOTE: By continuing to Press the Command, the system will toggle Answering (ON OFF)./

Page 14

Remote Dial-up Answer Configuration ���

Doorbell Relay #3 Configuration ���

Continued

Continuedon Page-15

Multi-Relay Trigger Configuration ���This feature allows multiple (2) relays to be triggered upon a door button press.

1) PRESS2) Listen for one (1) .3) Enter Door Station number.4)

���BEEP

Listen for one (1) .5) Enter relays to be trigger upon button press. (i.e. 12 will fire relays 1 and 2 upon button press. Note:

The system requires a 2 digit entry. If only one relay is required enter a 0 for thesecond digit)

6) Listen for two (2) for acceptance of programming.

BEEP

BEEPS

Page 17: Manual May30 A202CR & A204CRlogenex.com/oldsite/downloads/discontinued/A200... · when some service or repair is required. Opening or removing covers may expose you to dangerous voltages

Programming System Features [continued]

Programming Guide

This feature allows you to activate the Door Station Call Forwarding feature. When the Door StationSpeaker Button is pressed and the call is not answered from one of the premise phone(s) within aspecific time limit, the TeleDoorBell will then pick-up the phone line and dial the pre-programmed callforwarding number and if answered, allows the user to communicate to the Door Station Speakerremotely and perform all the functions as though they were within the premises.

1) PRESS2) Listen for

���

(1) BEEP.

3) Enter the Phone Number you wish to Call Forward to. 1

4) PRESS to SAVE

(up to 30 Digits)

NOTE: To DISABLE the Call Forwarding feature see USER GUIDE Door Station Call Forwarding Functions Page 13.

To Change a Door Station Call Forwarding Number ... Repeat STEPS 1-4.

..... 30

Note: ENTER for inserting a PAUSE (6 Second Delay) anywhere in the dialing sequence.

(2) BEEPS will be heard for acceptance of programming.

Page 15

Programming the Door Station Call Forwarding Phone# ���

Continued

Continuedon Page-16

This feature allows you to program the relay’s activation timing. Relay timing setting can be from 0.5seconds to 49 seconds, latching or for closure upon door station button press.

1) PRESS���

2) Select RELAY you wish to program: PRESS

3) Enter RELAY 2-Digit Timing Setting:

4) Listen for

� � � �OR OR OR .

(2) BEEPS for acceptance of programming.

* A202 models Relays #1 and #2 are programmable.

* A204 models Relays #1, #2, #3 and #4 are programmable.

� �- = in Seconds, [FACTORY DEFAULT SETTING = 6]

NOTE: In a power failure situation, any programmed LATCHED Relay(s) in the LATCHED [ON] position will be reset to UN-LATCHED State [OFF]. This is to prevent any devices from inadvertently being activated for an indefinite period of time.

Relay Timing Configuration ���

Call Forward Hang-Up Time ��

This feature allows the call forwarding hang up time to be shortened from the factory default oftwenty (20) minutes for specialized applications.

1) PRESS2) Listen for

4) Listen for

��(1) BEEP.

3) Enter - seconds. Note: Entering will set the hang up time to the factory default oftwenty (20) minutes.

� �

(2) BEEPS for acceptance of programming.

Page 18: Manual May30 A202CR & A204CRlogenex.com/oldsite/downloads/discontinued/A200... · when some service or repair is required. Opening or removing covers may expose you to dangerous voltages

Programming System Features [continued]

Programming Guide

This function allows the you to restore all programming back to factory default. All programming and settingswill be deleted. PASSCODE not required to perform this programming function. This command should beused only for critical situations where the system might require a reset. This command will erase all settings,including phone numbers in memory.

1) Pick-up Phone Handset (listen for dial tone) and ENTER��

(Unit will be defaulted back to Factory Settings including the PASSCODE)

2)

3) ENTER4) Listen for5) WAIT FOR DIAL TONE6) HANG-UP

Listen for (2) Beeps

�(2) Beeps for acceptance of programming.

(to be heard in the phone handset)

This feature allows the user to change their 4-Digit PASSCODE. (FACTORY DEFAULT )����

1) PRESSListen for

��2) (1) BEEP.

(If a new 4 Digit code is not entered within 10 seconds then the previous programmed code will remain)3) ENTER NEW (4 DIGIT) CODE

4) Listen for

( for acceptance of programming.2) Beeps

Page 16

Changing the 4-Digit PASSCODE ��

RESETTING THE UNIT TO FACTORY DEFAULT SETTINGS

Continued

Page 19: Manual May30 A202CR & A204CRlogenex.com/oldsite/downloads/discontinued/A200... · when some service or repair is required. Opening or removing covers may expose you to dangerous voltages

HI-FI Series User/Programming Guide

Page 17

Muting Function ON / OFF ���

1) Pick up phone handset and enter programming2) Enter programming password (default is )3) Enter to toggle muting on/ off

2 Beeps = Muting on3 Beeps = Muting off

��

����

���

(factory default)

Hi-Fi Feature Operations

On a door station call the will mute for 1 minute. If the call isanswered, the system will remain muted for the duration of the call. The

will un-mute once communication has ended.

TeleDoorBell

TeleDoorBell

On an incoming call the will mute on the first ring. If the callremains unanswered after the third ring the will initiate aRing-Over-Page feature for the remainder of the ring cycle.

TeleDoorBellTeleDoorBell

- Pick up hand set

- Press

- will activate muting and send page announcement tones.TeleDoorBell

��

Paging Operations

**The above features are only available with HI-FI Series Units.

Page 20: Manual May30 A202CR & A204CRlogenex.com/oldsite/downloads/discontinued/A200... · when some service or repair is required. Opening or removing covers may expose you to dangerous voltages

TroubleShooting

Page 18

Controller does not power up.

My phones ring but they do not communicatewith the outside doorstation.

My phones do not ring, but when I answer thephone I have communication to the door station.

I have a dial tone feedback at the speaker whendoor speaker button is pressed.

When pressing ... for monitoring anyof the connected door station speaker(s) you getan operator recording (e.g. "this is an invalidnumber") and you have no communication to thespeaker.

��� ���

Controller powers up but red LED does not flash,it is solid.

Controller powers up, red LED is flashing, but thedoor station does not power up, the phones donot ring, and there is no communication.

Problem SolutionPlease check these items before calling for support.

Problem Solution1)Check your AC voltage and power adapter,

confirm LED light is flashing.2)Check power connection into the unit.

1)The unit may have locked up, unplug the poweradapter and reconnect after 10 seconds.

2)Check for a short between the red and greenwire going to door station.

1)The red and green wire to the door station iseither reversed, has a short, or has a break inconnection. (verify this by plugging the door

station in another available speaker relay port).

1)The line you are connected on may have highspeed DSL internet on it. This will createinterference. A properly installed LX-DSL3F highspeed filter is required.

1)The ringer may be disabled. Please refer toUser Guide to enable the ringer.

2)There may be too many phones whichthe unit is trying to ring. unplug a few phones toverify.

1)Reverse the in and out on the RJ31X/CA38Adata jack.

1)You have the unit in parallel with the phones onthe C/O line.

2)The phone may not be touch tone compatible.3)The controller may be wired on the wrong

phone line.

Page 21: Manual May30 A202CR & A204CRlogenex.com/oldsite/downloads/discontinued/A200... · when some service or repair is required. Opening or removing covers may expose you to dangerous voltages

Page 19

My phones ring as soon as the wires are pluggedinto the door station.

Communication is very low when talking to thedoor station.

My phones ring pattern is the same as anincoming call and I cannot tell the differencebetween the two.

Door stations #3 and #4 do not ring when I pushthe door station button.

I cannot make outgoing long distance phonecalls.

My TeleDoorBell is not cal forwarding to theassigned number.

There is no video feed coming out of door station.Video feed does not modulate or picture quality ispoor on assigned channel.

Problem Solution1)The line you are connected on may have high

speed DSL internet on it. This will createinterference. A properly installed LX-DSL3F highspeed filter is required.

1)The unit is set on 6 standard ring pattern.Please refer the ring pattern setting.

2)Your phones/phone systems do not recognize’s distinctive ring pattern.

(PAGE 13)

TeleDoorBell

1) The may not be an A204 model.Please refer to model label on controller and orbarcode on unit box.

TeleDoorBell

1)Call restriction may be enabled. Please referthe programming section to clear memory bins.

2)A factory reset may be required. Please refer toprogramming section.

(PAGE 13)

(PAGE16)

1)Try reprogramming the call forwarding number.2) Try Adding a pause or pauses ( ) before thecall forwarding number.3)Call forwarding may not be enabled. Please

refer to the call forwarding section in theUser Guide.

1)Check for proper DC voltage power to the doorstation.

2)You may be broadcasting on a channel withsignal already present. An appropriate filtermay be required.

TroubleShooting

Problem SolutionPlease check these items before calling for support.

Problem Solution

1)The red and green wire to the door station iseither reversed, has a short, or has a break inconnection. (verify this by plugging the door

station in another available speaker relay port).

Page 22: Manual May30 A202CR & A204CRlogenex.com/oldsite/downloads/discontinued/A200... · when some service or repair is required. Opening or removing covers may expose you to dangerous voltages

Warranty / Terms & Conditions

Page 20

Limited Warranty

International Warranty

Warranty Procedure

Conditions to Void Warranty

Disclaimer of Warranties

Logenex Innovations Inc. warrants the original purchaser that for a period of one (1) year from the date of purchase, the product shall be free of defects inmaterials and workmanship under normal use.

During the warrantyperiod, Logenex . shall, at its option, repair or replace any defective product upon return of the product to its factory, at no charge for laborand materials (shipping, customs and/or brokerage fees are not included in the warranty). Any replacement and/or repaired parts are warranted for theremainder of the original warranty or sixty (60) days, whichever is longer. The original owner must promptly notify Logenex in writing thatthere is a defect in material or workmanship, such written notice to be received in all events prior to expiration of the warranty period.

.of ur manufactured product(s).

( )

The warranty for international customers is the same as for any customer within Canada and the United States, with the exception that LogenexInnovations Inc. shall not be responsible for any shipping fees, customs fees, taxes, or VAT that may be due.

To obtain service under this warranty, please return the item(s) in question to the point of purchase first for all your warranty and technical support issues.If unable to obtain warranty service, USER / DEALER must then:

All authorized distributors and dealers must have a warranty program.Logenex Innovations Inc. will not accept any shipment whatsoever for which prior authorization has not been obtained.

This warranty applies only to defects in parts and workmanship relating to normal use. It does not cover:- damage incurred in shipping or handling;- damage caused by disaster such as fire, flood, wind, earthquake or lightning;- damage due to causes beyond the control of Logenex Innovations Inc. such as excessive voltage, mechanical shock or water damage;- damage or in-operation of the product(s) as a result of changes made by any other Service Providers (ie: Phone, Electricity, Security, Internetcompanies)

- damage caused by unauthorized attachment, alterations, modifications or foreign objects;- damage caused by peripherals (unless such peripherals were supplied by Logenex Innovations Inc.);- defects caused by failure to provide a suitable installation environment for the products;- damage caused by use of the products for purposes other that those for which it was designed;- damage from improper maintenance;- damage arising out of any other abuse, mishandling or improper application of the product(s).

Logenex Innovations Inc.'s liability for failure to repair the product under this warranty after a reasonable number of attempts will be limed to areplacement of the product, as the exclusive remedy for breach of warranty. Under no circumstances shall Logenex Innovations Inc. be liable for anyspecial, incidental, or consequential damages based upon breach of warranty, breach of contract, negligence, strict liability, or any other legal theory.Such damages include, but are not limited to, loss of profits, loss of the product or any associated equipment, cost of capital, cost of substitute orreplacement equipment, facilities or services, down time, purchaser's time, the claims of third parties, including customers, and injury to property.

This warranty contains the entire warranty and shall be in lieu of any and all other warranties, whether expressed or implied (including all impliedwarranties of merchantability or fitness for a particular purpose) and of all other obligations or liabilities on the par of Logenex Innovations Inc. LogenexInnovations Inc. neither assumes nor authorizes any other person purporting to act on its behalf to modify or to change this warranty, nor to assure for itany other warranty or liability concerning this product. This disclaimer of warranties and limited warranty are governed by the laws of the province ofOntario, Canada.

Except as specifically stated herein, all express or implied warranties whatsoever, statutory or otherwise,including without limitation, any implied warranty of merchantability and fitness for a particular purpose, are expressly excluded.

Innovations Inc

Innovations IncBecause Logenex

Innovations Inc does not install or connect the products and because the products may be used in conjunction with products not manufactured byLogenex Innovations Inc., Logenex Innovations Inc. cannot guarantee the performance o Logenex Innovations Inc.obligation and liability under this warranty is expressly limited to repairing or replacing at Logenex Innovations Inc.'s option any product not meeting thespecifications. In no event shall the Logenex Innovations Inc. be liable to the buyer or any other person for any loss or damages whether direct or indirector consequential or incidental, including without limitation, any damages for lost profits, stolen goods or claims by any other party, caused by defectivegoods or otherwise arising from the improper, incorrect or otherwise faulty installation or use of the merchandise sold.No Dealer and no person other than an officer of Logenex Innovations Inc. may extend or modify this warranty, and no modification or extension of thiswarranty shall be effective unless in writing signed by the authorized officer of Logenex Innovations Inc..

(1) USERS must provide written notice of the malfunction to an authorized Logenex Innovations Inc. Dealer within the warranty period and no later than15 days after the date of the malfunction, whichever occurs first. If the USER is unable to identify an authorized Logenex Innovations Inc. Dealer, USERmust provide written notice of the malfunction, including proof of the date of purchase of the equipment and the serial number of the malfunctioningProduct, to Logenex Innovations Inc. at its corporate offices at 27 Armthorpe Rd Unit 3, Brampton, Ontario, L6T 5M4. Upon receipt of such notice anddetermination by Logenex Innovations Inc. that User is eligible for Warranty service, Logenex Innovations Inc. will provide the USER with the necessaryinstructions to process the warranty service.

(2) DEALERS must provide written notice of the malfunction to Logenex Innovations Inc. no later than the expiration of the warranty period or 15 daysafter the date the Dealer becomes aware of the malfunction, whichever comes first. For purposes of this Warranty, the Issuance by Logenex InnovationsInc. of a Return Material Authorization (RMA) number by telephone to an authorized Dealer shall be deemed to be written notice from the dealer withrespect to the material returned under that RMA number.

Page 1 of 2

Warranty / Terms & Conditions Continued on next page...

Page 23: Manual May30 A202CR & A204CRlogenex.com/oldsite/downloads/discontinued/A200... · when some service or repair is required. Opening or removing covers may expose you to dangerous voltages

Warranty / Terms & Conditions

Page 21

Page 2 of 2

WARNING: Logenex Innovations Inc recommends that the entire system be completely tested on a regular basis. However, despite frequent testing,and due to, but not limited to, criminal tampering, telephone provider breakdowns, interference or poor signal or electrical disruption, it is possible for thisproduct to fail to perform as expected.

Logenex Innovations Inc. will at its option repair or replace out-of-warranty products which are returned to its factory according to the followingconditions. Customers are required to contact their local installation dealer first for proper inspection and diagnostics before returning goods to LogenexInnovations Inc. and must also obtain an authorization Return Number (RMA). Logenex Innovations Inc. will not accept any shipment whatsoeverwithout prior authorization and Return Number (RMA). Products which Logenex Innovations Inc. determines to be repairable will be repaired andreturned. A set fee which Logenex Innovations Inc. has predetermined and which may be revised from time to time, will be charged for each unitrepaired. Products which Logenex Innovations Inc. determines not to be repairable will be replaced by the nearest equivalent product available at thattime. The current market price of the replacement product will be charged for each replacement unit. Customer would also have the option to contacttheir local dealer for product pricing and installation rates (if required).

Out of Warranty Repairs

Notification To Telephone Company

Telephone Connection Requirements

Incident of Harm

Changes in Telephone Company Equipment, Service and/or Facilities

Attachment Limitation Notice

Upon request, customer shall notify telephone company of particular line to which the connection will be made, and provide the FCC registration numberand the ringer equivalence of the protective circuit.

Except for telephone company provided ringers, all connections to the telephone network shall be made through standard plugs and telephonecompany provided jacks, or equivalent, in such a manner as to allow for easy, immediate disconnection of terminal equipment.

Should terminal equipment/protective circuitry cause harm to telephone network, telephone company shall, where practicable, notify customer thattemporary disconnection of service may be required; however, where prior notice is not practicable, the telephone company may temporarily discontinueservice if action is deemed reasonable in circumstances.

The telephone company may make changes in its communication facilities, equipment operations or procedures, where such actions are reasonable,required and proper in its business. Should any such changes render customer's terminal equipment incompatible with the telephone company facilitiesor any products installed, Logenex Innovations Inc. will not held responsible for any failures or problems which may occur as a result of such changes,failures and/or interruptions of the service.

Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company.The equipment must also be installed using an acceptable method of connection. The customer should be aware that compliance with the aboveconditions may not prevent degradation of service in some situations. Users should ensure for their own protection that the electrical ground connectionsof the power utility, telephone lines and internal metallic water pipe system, if present, are connected together. This precaution may be particularlyimportant in rural areas.

The Load Number (LN) assigned to each terminal device denotes the percentage of the total load to be connected to a telephone loop which is used bythe device to prevent overloading. The termination on a loop may consist of any combination of devices subject only to the requirement that the total ofthe Load Numbers of all of the devices does not exceed 100. (Confirm Load Number (LN) with your local Phone Service Provider)

CAUTION: Users should not attempt to make such connections themselves, but should contact the appropriateelectrical inspection authority, or electrician, as appropriate.

Industry Canada certification is only applicable to installation of devices which include transformers approved by the Canadian Standards Association (CSA).

The sole obligation of Logenex Innovations Inc. under this warranty is, at the sole option of Logenex Innovations Inc., therepair or replacement, with new or refurbished parts, of the defective or missing parts that are causing the malfunction andwhich are determined to be defective be Logenex Innovations Inc., and the return shipment of such parts to the DEALER /USER / DISTRIBUTOR. DEALER / USER / DISTRIBUTOR shall be responsible to pay for shipment of the defective part toLogenex Innovations Inc. and for all expenses connected with their removal and reinstallation. In lieu of repair or replacement,Logenex Innovations Inc. may, at its sole option and in full satisfaction of its warranty obligations hereunder, refund the pricecharged by Logenex Innovations Inc. to its DEALER / USER / DISTRIBUTOR for such parts as are determined by Logenex tobe defective and which are returned to Logenex Innovations Inc. through an authorized dealer within the warranty period andno later than 15 days after such malfunction, whichever occurs first.

Warranty / Terms & Conditions Continued ...

Page 24: Manual May30 A202CR & A204CRlogenex.com/oldsite/downloads/discontinued/A200... · when some service or repair is required. Opening or removing covers may expose you to dangerous voltages

Manufacturing Plant:6A-7500 Martin Grove Rd.

Woodbridge, ON. Canada L4L 8S9Phone: 905-790-8823 Toll Free: 1-888-790-5900

E mail: info@ ogenex.com- lwww.logenex.com

May 2008