8.01 SITE PLAN MEPT
8.02 MECHANICAL COVER SHEET
8.03 DEMOLITION PLAN - MECHANICAL & FLOOR PLAN - MECHANICAL
8.04 MECHANICAL SCHEDULES AND DETAILS
10.02 ELECTRICAL COVER SHEET
10.03 DEMOLITION PLAN - ELECTRICAL & FLOOR PLAN - LIGHTING
10.04 FLOOR PLAN POWER
4.00 EXISTING/DEMOLITION & NEW FLOOR PLANS
5.20 EXTERIOR ELEVATIONS
5.60 DOOR SCHEDULES, FRAMES, TYPES & DETAILS
6.00 REFLECTED CEILING PLAN
7.00 FIXTURE, FINISH & EQUIPMENT PLAN
7.30 CASEWORK ELEVATIONS & DETAILS
2.00 GENERAL NOTE
2.10 PAVING/GRADING PLAN
1.00 COVER SHEET
1.01 CITY OF MANOR CONSTRUCTION NOTES
1.02 DEMOLITION & SITE PLAN
1.03 CODE ANALYSIS & LIFE SAFETY PLAN
1.04 SITE DETAILS - FENCES & GATES
ARCHITECTURAL SITE
MANOR ISD / POLICE STATION RENOVATION - CSP #600(RM)21-00 MANOR, TEXAS
SCALE:1" = 2000'-0"
VICINITY MAPNORTH
INDEX OF SHEETS
REVIEWED BY:DIRECTOR OF DEVELOPMENT SERVICES DATE
REVIEWED BY:DEPARTMENT OF PUBLIC WORKS DATE
REVIEWED BY:CITY ENGINEER DATE
REVIEWED BY:TRAVIS COUNTY ESD NO. 12 DATE
ALL RESPONSIBILITY FOR THE ADEQUACY OF THESE PLANS REMAINS WITH THE ENGINEER WHO PREPARED THEM. IN REVIEWING THESE PLANS, THE CITY OF MANOR AND TRAVIS COUNTY ESD NO. 12 MUST RELY UPON THE ADEQUACY OF THE WORK OF THE DESIGN ENGINEER. REVIEW OF THE SUBMITTED MATERIALS DOES NOT CONSTITUTE A VERIFICATION OF ALL DATA, INFORMATION AND CALCULATIONS SUPPLIED BY THE APPLICANT. THE ENGINEER OF RECORD IS SOLELY RESPONSIBLE FOR THE COMPLETENESS, ACCURACY AND ADEQUACY OF HIS/HER SUBMITTAL, WHETHER OR NOT THE APPLICATION IS REVIEWED FOR ORDINANCE COMPLIANCE BY THE CITY ENGINEER.
PROJECT NAME: MANOR ISD POLICE STATION
SITE ADDRESS: 312 W MURRAY AVE., MANOR, TX 78653
CURRENT ZONING: I- INSTITUTIONAL
OWNER: MANOR INDEPENDENT SCHOOL DISTRICT
CONTRACTOR: T.B.D.
ARCHITECT: CLAYCOMB ASSOCIATES ARCHITECTS - (512) 263-7940
ENGINEER: IMEG CORP. - (214) 485-6433
SITE AREA: 1.371 ACRES (CONSTRUCTION AREA)
IMPERVIOUS COVER: 40,820 SF
BUILDING COVERAGE: 9,274 SF (EXISTING FOOTPRINT, RENOVATION)
LEGAL DESCRIPTION: ABS 546 SUR 40 MANOR J ACR1.371
SITE SUMMARY
CIVIL
ARCHITECTURAL
MEPT
MANOR EXPRESSWAY (HWY 290)
MANOR EXPRESSWAY (HWY 290)
PROJECT LOCATION312 W. MURRAY AVE.MANOR, TX
W. MURRAY AVE.
NO
D
AT
E R
EV
ISIO
NS
A
PP
V.
SHEE
T N
O.
CLAY
COM
B AS
SOCI
ATES
, ARC
HITE
CTS
* 511
3 SO
UTHW
EST
PKW
Y * S
UITE
100
AUST
IN, T
EXAS
787
35 *
WW
W.C
LAYC
OM
B.NE
T
1.01
Man
or, T
exas
MAN
OR
IND
EPEN
DAN
TSC
HO
OL
DIS
TRIC
T
MAN
OR
ISD
JOB
NO
. 220
15
DAT
E: 0
8.15
.202
0
POLI
CE
STAT
ION
REN
OVA
TIO
NIS
SUE:
BID
ISSU
E
08/15/20
HC HC HCRSVHC
SIGN #1
VAN
SIGN #2
SIGN #1
REAR PARKING SPACES26 PARKING SPACES
FRONT PARKING SPACES15 REGULAR SPACES 3 HC SPACES18 TOTAL PARKING SPACES
EXISTING HVAC YARD
EXISTING CCC BUILDING9,274 SF
6'-0"
6"
1'-0"
WEST MURRAY AVE HIG
HWAY 290
10A
10B 10B
10B
10B
10B
10D
10E
10F
10M
10M
10M
10L
10L
10L
10L
10L
10L
10L
10L
10C
10Q
10R
10R10R
10R
10R
10R
10C 10L
10N
10N
10P
10G10G10G10G
10R
10R10R10R
10R
10J 10J
45'-0" ±
9'-0" ±
10K
10K
10'-6"
10D
REAR PARKING SPACES19 REGULAR SPACES1 HC SPACE20 PARKING SPACES
FRONT PARKING SPACES17 REGULAR SPACES1 HC SPACE18 TOTAL PARKING SPACES
EXISTING HVAC YARD
EXISTING CCC BUILDING9,274 SF
WEST MURRAY AVE HIG
HWAY 290
9'-0" 9'-0" 9'-8" 11'-0" 10'-0" 9'-0" 9'-0" 9'-0"
9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 10'-0"
109'-0"
75'-8"
50A50B50C
50A50B50C
50A50B50C
50A50B50C
20A
20C
30B
30B
20D
20E
20E
20E
20G
20H
20J
20N
20L
20M
20M
20M
20M
20M
20M
20M
20M
20M
30A
20D20D
30F 30F
30D 30D20G20G
5'-0"
22'-0"
32'-0"
20A
VAN
20A
20B
30E
30D 30D
20K
20D
20H
1.02
5
22'-0"
64'-3
"
42'-0"
9'-0" 9'-0" 9'-0" 11'-0" 15'-0" 9'-0" 9'-0" 9'-0"
80'-0"
9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" 9'-0"
117'-0"
20D
SIGN #3 SIGN #3
SIGN #3
MANOR ISD PROGRAM SIGN
LANDSCAPE PLAN LEGEND
SMALL ORNAMENTAL TREES
CREPE MYRTLE- BURLAP BAGGED (3" CALIPER ORNAMENTAL TREE) - LAGERSTROEMIA INDICA
MOUNTAIN LAUREL - BURLAP BAGGED (3" CALIPER ORNAMENTAL TREE) - SOPHORA SECUNDIFLORA
JAPANESE BOXWOOD SHRUB AT 5'-0" O.C.- BUXUS MICROPHYLLA
SCREENING SHRUBS
3'-6"PER MANUF.6'-0"
NEW 1 1/2" DEEP SAW CUT IN EXISTING PAVEMENT FOR NEW VEHICLE LOOP DETECTOR SYSTEM PER MANUF. DETAILS.
NEW 20' MOTORIZED 6' TALL CANTILEVERED GALV. CHAIN LINK GATE (20' OPENING & 10' COUNTERBALANCE) W/ OPERATOR AND BARBED WIRE, REF DTL 01/1.04
NEW 4' WIDE X 6' TALL CHAIN LINK GATE W/ BARBED WIRE AND EXIT DEVICE
NEW 8' TALL (6' FENCE + 2' WIRE, MATCH EXISTING) CHAIN LINK FENCE W/ BARBED WIRE, REF DTL 2,3 & 4/1.04
NEW PARKING STRIPPING
NEW 6" DIA. BOLLARD, REF DTL 07/1.04
EXISTING CONCRETE CURB TO REMAIN
EXISTING CHAIN LINK FENCING TO REMAIN
GA
TE
PA
TH
SECTION OF CURB REMOVED
SIGN: 3/4" PLYWOOD, EXTERIOR GRADEPOST: 4" X 4" W/ 4" X 4" HORIZONTAL BRACES
PAINT BACKGROUND "WHITE BUFF" (P2519)(TYP ALL BACKGROUND)
NOTE: ALL COLORS REFER TO PITTSBURGHPAINT CO. - ANCHOR PLYWOOD TO POST W/1/2" O THRU BOLTS AND NUTS (6) (SPACING AS INDICATED)
GRAPHIC RENDERING, ELECTRONIC FILE. VERIFY ALL NAMES WITH DISTRICT.
BOLTS
4'-0"
4'-0"
4'-0"
2"
Board of Trustees
President
Vice President
Secretary
Trustee
Trustee
Trustee
Trustee
Superintendent
Elmer Fisher Jr.
Monique Celedon
Johnny R. Velasco
Ana Cortez
Matildy Samaripa, Jr.
Janie Serna
Dr. Royce Avery
Temeika Thomas
Districts' Logo
Contractor's Logo
BOLTS
3'-0"
2'-0"
4'-0"
4'-0"
2"
1'-8"
2"
MANOR ISD
HUMAN SERVICES
AND WELLNESS
PROGRAM VISITOR
ENTRANCE
2" 2'-8" 2"
SHEE
T N
O.
CLAY
COM
B AS
SOCI
ATES
, ARC
HITE
CTS
* 511
3 SO
UTHW
EST
PKW
Y * S
UITE
100
AUST
IN, T
EXAS
787
35 *
WW
W.C
LAYC
OM
B.NE
T
1.02
Man
or, T
exas
MAN
OR
IND
EPEN
DAN
TSC
HO
OL
DIS
TRIC
T
MAN
OR
ISD
JOB
NO
. 220
15
DAT
E: 0
8.15
.202
0
POLI
CE
STAT
ION
REN
OVA
TIO
NIS
SUE:
BID
ISSU
E
08/15/20
SCALE: 1" = 20'-0"1
EXISTING / DEMO SITE PLAN
GENERAL NOTES - SITE PLAN1. THE INFORMATION SHOWN ON THESE DRAWINGS CONCERNING TYPE AND
LOCATION OF UNDERGROUND AND OTHER UTILITIES IS NOT GUARANTEED TO BE ACCURATE OR ALL INCLUSIVE. THE CONTRACTOR IS RESPONSIBLE FOR MAKING HIS OWN DETERMINATIONS AS TO THE LOCATION, EXTENT AND TYPE OF ALL UTILITIES AND STRUCTURES AS NECESSARY TO AVOID DAMAGE AND DETERMINE SCOPE OF WORK. ANY DAMAGE CAUSED BY THE CONTRACTOR SHALL BE AT THE CONTRACTOR'S RISK AND REPAIRED AT THE CONTRACTOR'S EXPENSE. LOWER AND/OR RELOCATE ALL EXISTING UTILITIES AS REQUIRED. CAP AND/OR RE-ROUTE EXISTING UTILITIES AS REQUIRED TO MAINTAIN FUNCTIONS. COORDINATE WITH OWNER TO MAINTAIN CONSISTENT OPERATION OF UTILITIES. THE CONTRACTOR IS TO VISIT THE SITE OF PROPOSED CONSTRUCTION TO VERIFY EXISTING CONDITIONS AND IS TO NOTIFY THE ARCHITECT OF ANY DISCREPANCIES OR QUESTIONS PRIOR TO THE SUBMISSION OF BID. REFER TO THE SPECIFICATIONS. ALL INFORMATION REGARDING EXISTING FIELD CONDITIONS, MATERIALS, METHODS OF CONSTRUCTION AND DIMENSIONS SHALL BE OBSERVED, NOTED, AND VERIFIED BY THE CONTRACTOR PRIOR TO ANY CONSTRUCTION OR FABRICATION.
2. THE CONTRACTOR SHALL PROTECT AND PRESERVE ALL EXISTING IMPROVEMENTS NOT SCHEDULED TO BE REMOVED, REPAIRED OR ADDED AGAINST DAMAGE.REPAIR AND/ OR REPLACE ALL MATERIALS DAMAGED DURING DEMOLITION.ANY DAMAGE DONE SHALL BE REPAIRED TO THE SATISFACTION OF THE OWNER AND THE ARCHITECT.
3. ALL NATURAL VEGETATION SHALL BE MAINTAINED WHERE IT DOES NOT INTERFERE WITH CONSTRUCTION OR THE PERMANENT PLAN OF OPERATION. EVERY EFFORT POSSIBLE SHALL BE MADE TO PROTECT VEGETATION FROM DAMAGE DUE TO EQUIPMENT USAGE. CONTRACTOR SHALL AT ALL TIMES PROTECT ALL MATERIALS AND WORK AGAINST INJURY TO PUBLIC.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY COORDINATION WITH OTHER SITE RELATED WORK BEING PERFORMED.
5. UNDERGROUND FACILITIES, STRUCTURES AND UTILITIES MUST BE CONSIDERED APPROXIMATE ONLY. THERE MAY BE OTHERS NOT PRESENTLY KNOWN OR SHOWN. IT SHALL BE THE CONSTRUCTION MANAGERS OR CONTRACTORS RESPONSIBILITY TO DETERMINE OR VERIFY THE EXISTENCE OF AND EXACT LOCATION OF THE ABOVE.
6. ALL BIDS ARE TO HAVE UNIT PRICES LISTED. 7. SILT FENCE TO BE INSTALLED BEFORE GROUND IS BROKEN AND TO REMAIN UP
AT ALL TIMES UNTIL PROJECT COMPLETION, AND BE COMPLAINT WITH SWPPP.
NORTH
SCALE: 1" = 20'-0"2
NEW SITE PLAN NORTH
DEMO SITE NOTE SCHEDULENUMBER NOTE
10 DEMOLITION SITE WORK
10A REMOVE PORTION OF DAMAGED ASPHALT AS SHOWN ON PLAN
10B REMOVE ALL EXISTING PARKING STRIPING
10C REMOVE ROCKS/GRAVEL, SALVAGE FOR REUSE.
10D REMOVE PORTION OF CURB AND SIDEWALK AS SHOWN ON PLAN
10E REMOVE EXISTING DUMPSTER AND SALVAGE FOR REUSE.
10F REMOVE EXISTING PAVING AND LANDSCAPE FOR MOTORIZED GATE PEDESTAL TRENCH.
10G REMOVE EXISTING CURB AND GUTTER AS SHOWN ON PLANS
10H REMOVE PORTION OF ASPHALT PAVING AS SHOWN
10J REMOVE EXISTING WHEEL STOPS TO BE SALVAGED AND PROTECTED FOR REUSE
10K REMOVE PORTION OF EXISTING CHAIN LINK FENCE W/ BARBED WIRE
10L EXISTING CONCRETE CURB AND GUTTER TO REMAIN, TYP.
10M EXISTING EXTERIOR LIGHT BASES TO REMAIN. EXTERIOR LIGHT FIXTURES TO BE REMOVED AND REPLACED.
10N EXISTING CHAIN LINK FENCING W/ BARBED WIRE TO REMAIN.
10P EXISTING CURB AND RAMP TO REMAIN.
10Q EXISTING FLAG POLE TO REMAIN.
10R EXISTING LANDSCAPE TO REMAIN.
SITE NOTES SCHEDULENUMBER NOTE
20 SITE WORK
20A NEW 6' TALL SECURITY CHAIN LINK FENCE
20B NEW MOTORIZED GATE WITH SECURE ACCESS.
20C NEW 6' TALL MANUALLY OPERATED CHAIN LINK GATE WITH CHAIN CLOSURE AND LOCK.
20D NEW POLE MOUNTED SITE LIGHTING FIXTURES AS SHOWN.
20E NEW LIGHTING FIXTURE IN EXISTING SITE LIGHTING BASE
20F NEW SHRUBS AND TREES AS SHOWN ON PLAN
20G NEW CONCRETE FLUME AS SHOWN. REINSTALL SALVAGED GRAVEL AFTER NEW GRADING IS COMPLETED.
20H NEW CONCRETE CURB, RAMP AND SIDEWALK AS SHOWN ON PLAN
20J NEW 64" TALL MANUAL OVERRIDE KEYPAD W/ 6" DIA BOLLARDS AND TRENCH
20K NEW 8' TALL SECURITY SINGLE CHAIN LINK GATE W/ EXIT DEVICE
20L EXISTING DUMPSTER TO REMAIN.
20M EXISTING CURB AND GUTTER TO REMAIN.
20N EXISTING CURB AND RAMP TO REMAIN.
30 PARKING / CONCRETE
30A NEW HEAVY CONCRETE PAVING (BASE BID)
30B NEW PARKING STRIPING AND ADA PATH STRIPING
30C NEW CONCRETE CURB AND RAMP
30D NEW WHEEL STOPS AS SHOWN ON PLAN
30E NEW BOLLARDS AS SHOWN ON PLAN
30F EXISTING SALVAGED WHEEL STOPS
PAVING NOTESNUMBER NOTE
50 PAVING
50A BASE BID - PROVIDE PATCHING, REPAIRS, AND RESURFACE THE EXISTING PARKING AND DRIVES WITH ASPHALT
50B ALT #1 - REMOVE EXISTING ASPHALT AND CONCRETE, REPLACE WITH NEW ASPHALT PARKING AND DRIVES
50C ALT #2 - REMOVE EXISTING ASPHALT AND CONCRETE, REPLACE WITH NEW CONCRETE PARKING AND DRIVES
LANDSCAPE REQUIREMENTS (COMPLIES WITH MANOR ORDINANCE
SECTION 15.03.005 LANDSCAPE REQUIREMENTS - JUNE 10TH 2020)
THE LANDSCAPES AND IRRIGATION WILL BE PROVIDED BY SCHOOL DISTRICT.
TOTAL SQUARE FOOTAGE OF SITE: 59,677 SQUARE FEET
15% OF PLANTER NEEDED - AS PER CITY OF MANOR ORDINANCE59,677 SF X 15% = 8,952 SQ FT
REQUIRED PLANTING - FOR EVERY 600 SF OF REQUIRED LANDSCAPE AREA (2) TREES AND (4) SHRUBS SHALL BE PLANTED FOR THE FIRST 20,000 SF OF REQUIRED LAND AREA. FOR EVERY 600 SF OF REQUIRED LANDSCAPED AREA IN EXCESS OF 20,000 SF SHALL PLANT (1/8) TREE AND (3) SHRUBS.
REQUIRED TREES - 30 (EXISITNG TREES 10, PROVIDED TREES 20)REQUIRED SHRUBS - 60 (VERIFY IN FIELD FOR THE NUMBER OF EXISTING SHRUBS)
PREFERRED TREE LIST1. CEDAR ELM2. NOUNTAIN LAUREL3. BUR OAK
OPTIONAL TREE LIST1. CREPE MYRTLE
PREFERRED SHRUB LISTA. JAPANESE BOXWOODB. INDIAN HAWTHORN
LANDSCAPING MAINTENANCE NOTE
THE DEVELOPER AND SUBSEQUENT OWNERS OF THE LANDSCAPED PROPERTY, OR THE MANAGER OR AGENT OF THE OWNER, SHALL BE RESPONSIBLE FOR THE MAINTENANCE OF ALL LANDSCAPE AREAS. SAID AREAS SHALL BE MAINTAINED SO AS TO PRESENT A HEALTHY, NEAT AND ORDERLY APPEARANCE AT ALL TIMES AND SHALL BE KEPT FREE OF REFUSEAND DEBRIS. ALL PLANTED AREAS SHALL BE PROVIDED WITH A READILY AVAILABLE WATER SUPPLY AND WATERED AS NECESSARY TO ENSURE CONTINUOUS HEALTHY GROWTH AND DEVELOPMENT. MAINTENANCE SHALL INCLUDE THE REPLACEMENT OF ALL DEAD PLANT MATERIAL IF THAT MATERIAL WAS USED TO MEET THE REQUIREMENTS OF THE SUBDIVISION REGULATIONS.
SCALE: 1/8" = 1'-0"5
ENLARGED FENCING PLANSCALE: 1" = 1'-0"
4JOB SIGN 4X4
SCALE: 1" = 1'-0"3
MISD PROGRAM SIGN
# OCC
FE
EGRESS PATH & TRAVEL DISTANCE
OCCUPANCY LOAD
LIFE SAFETY LEGEND
FIRE EXTINGUISHER CABINET
EX
IT
64"
EX
IT
64"
EXIT
32"
EXIT
32"
22 TOTAL OCCUPANCY
MAX. TRAVEL DISTANCE 111 FT
REQ'D EGRESS WIDTH
22x0.2" = 4.4"
EVIDENCEA109
TRAININGA106
PROCESSING/INTERVIEWA105
SHOPA112
CUBICLE OFFICESA103
VESTIBULEA104
ADMIN. ASSIST.A102
SOFT INTERVIEWA107
OFFICEA108
SEC. DOCS.A110
OFFICESA113
MENSA114
WOMENSA115
STORAGEA116
EXEC. ASSIST.A117
MEETINGA119
COFF/BRKA120
ELECTRICALA121
JAN.A123
MDFA124
STORAGEA125
TRAININGA126
OFFICEA127
P & W COORD.A128
ASST. DIR. HEALTH
SERVICES
A130
MENTOR COORD. &
GRANT DIR.
A132 DIR. HEALTH SERVICESA133
STORAGEA134
5 OCC
4 OCC
3 OCC
2 OCC 1 OCC
8 OCC
1 OCC
1 OCC
2 OCC
3 OCC
7 OCC
3 OCC7 OCC
7 OCC
6 OCC
2 OCC
4 OCC
1 OCC
1 OCC
10 TOTAL OCCUPANCY
MAX. TRAVEL DISTANCE 97 FT
REQ'D EGRESS WIDTH
10x0.2" = 2"
30 TOTAL OCCUPANCY
MAX. TRAVEL DISTANCE 95 FT
REQ'D EGRESS WIDTH
30x0.2" = 6"
8 TOTAL OCCUPANCY
MAX. TRAVEL
DISTANCE 80 FT
REQ'D EGRESS WIDTH
8x0.2" = 1.6"
1 OCC 1 OCC
FE
FE
FE
FE
APPLICABLE BUILDING CODES
2015 INTERNATIONAL BUILDING CODE w/ local amendments
2015 INTERNATIONAL FIRE CODE w/ local amendments
2015 INTERNATIONAL MECHANICAL CODE w/ local amendments
2015 INTERNATIONAL PLUMBING CODE w/ local amendments
2015 INTERNATIONAL FUEL & GAS CODE w/ local amendments
2014 NATIONAL ELECTRICAL CODEw/ local amendments
2015 INTERNATIONAL PROPERTY MAINTENANCE CODE w/ local amendments
2015 INTERNATIONAL ENERGY CONSERVATION CODE w/ local amendments
AMERICAN WITH DISABILITIES ACTS
2012 ICC/ANSI A117.1 - 2003
TEXAS ARCHITECTURAL BARRIERS CODE
CITY OF MANOR ORDINANCE
OCCUPANCY CLASSIFICATIONS
BUSINESS B
EGRESS TRAVEL DISTANCE
CONSTRUCTION TYPE
ADDITIONAL FIRE PROOFING REQUIREMENTS
FIRE EXTINGUISHERS SHALL BE PROVIDED EVERY 75’ OF TRAVEL
DISTANCE PER CITY OF MANOR FIRE DEPARTMENT
V-B - NON-SPRINKLERED
NON-SPRINKLED BUILDINGS: TRAVEL DISTANCE TO AN EXIT
DOOR SHALL NOT BE GREATER THAN 200 FT
AREA CALCULATIONS
EX
IST
ING
MA
NO
R
ISD
PO
LIC
E
ST
AT
ION
RENOVATED AREA CALCULATIONS
EXISTING ONE STORY BUILDING
GROUP B - TYPE V-B CONSTRUCTION - NON SPRINKLERED
CLASSIFICATION OF WORK:
ALTERATIONS LEVEL 2 PER 2015 IEBC SECTION 504
EXISTING TOTAL BUILDING AREA = 9,273 SF
RENOVATED BUILDING AREA = 2,474 SF
RENOVATED BUILDING AREA IS 27% OF TOTAL EXISTING BUILDING AREA
RENOVATED AREA
SHEE
T N
O.
CLAY
COM
B AS
SOCI
ATES
, ARC
HITE
CTS
* 511
3 SO
UTHW
EST
PKW
Y * S
UITE
100
AUST
IN, T
EXAS
787
35 *
WW
W.C
LAYC
OM
B.NE
T
1.03
Man
or, T
exas
MAN
OR
IND
EPEN
DAN
TSC
HO
OL
DIS
TRIC
T
MAN
OR
ISD
JOB
NO
. 220
15
DAT
E: 0
8.15
.202
0
POLI
CE
STAT
ION
REN
OVA
TIO
NIS
SUE:
BID
ISSU
E
08/15/20
SCALE: 1/8" = 1'-0"1
FLOOR PLAN - LIFE SAFETY
GATE OPERATOR
GATE OPERATOR CONCRETE PAD REF MFG
SLIDING GATE
4' OD POST WITH GATE GUIDES PER MFG, (TYP)
PIPE BOLLARD
2 1
/2"
5 1
/2"
1'-9"
4" 1'-4 1/2" 2'-1 1/2"
FENCING, REF PLAN
3'-9"
3'-9"
KNOX BOX W/ CHAIN DROP AS REQ'D
4"
1'-7"
4"
8"
7"
1'-4"
4" 8" 4"
1"
FIN
ISH
GR
AD
E
3'-4"
AB
OV
E2'-0"
4"
CONCRETE FOOTING
8" X 8" PLATE
2" X .120" X 64" BLACK TUBE W/ CONDUIT ACCESS ON BACKSIDE 23 1/2" FROM THE LOWEST POINT
NEW 4" X 4" X 1.20 FACE PLATE
PEDESTAL PLAN
PEDESTAL SECTION
6"
NEW HEAVY CONCRETE AS SCHED.
6" DIA. STEELPIPE FILLED WITHCONC. AND PAINT
ALL SURFACES SAFETY YELLOW
TOP ROUNDEDAND TROWELLED
SMOOTH
PAVING/FLATWORK
CONCRETE FOOTING
SECTIONELEV.
3'-6"
3'-0"
6"
2" SQ. DIAMONDPATTERN 9 GA. WIRE
PROVIDE CONC FOUNDATION @ EACH POST; TROWEL AND
SLOPE FINISH DOWNWARDFOR DRAINAGE
BOTTOM OF FABRIC 1/2" TO 3/4" ABOVECONC OR GRADE WITH KNUCKELED SELVAGE ON BOTTOM.
LINE POSTS TO BE 2.375" O.D. SCH. 40 GALV. PIPE @ 3.65
LBS/FT.
HORIZ BRACE ATENDS, BOTH SIDESOF CORNER ANDGATE POSTS
END, CORNER & PULLPOSTS TO BE 2.875" O.D. GALV. PIPE @ 5.79 LBS/FT.
3/8"DIA. GALV. RODW/ TRUSS TIGHTENER
STRETCHER BAR W/12 GA. GALV. FITTINGS
TIES @ 12" O.C., 9 GA. ON POSTS
TOP RAIL TO BE1.660" O.D. PIPE @2.27 LBS/FT. W/ TIES@ 24" O.C.
POST TOPS, DESIGNED AS A WEATHERTIGHTCLOSURE CAP (TYP).
TENSION WIRE, GALV. 7 GA. W/CLIPS 24" O.C.OR AS NEEDED
@ C
OR
NE
RS
40"
MIN
.
LIN
E P
OS
TS
36"
MIN
. @
6'-0",
UP
TO
8'-0"
10'-0" MAX. 10'-0" MAX. N.T.S.
ALL CHAIN LINK FENCING TO BE
GALVANIZED WITH BLACK VINYL-COATED FINISH, PRIVACY SLATS & RAZORWIRE.
HORIZ BRACE AT BOTH SIDES OF GATE POSTS
3/4" Ø TRUSS ROD AT LEAVES W/ 1" Ø RECEIVER IN SLAB
REF CHAIN LINK FENCE POST DETAIL
3/8"Ø GALV. ROD W/ TRUSS TIGHTENER
GATE POSTS, REF CHART FOR SIZING
REF. CHART
6'-0",
UP
TO
8'-0"
GA
TE
PO
ST
S
40"
MIN
ATMIN
.
8"
2" SQ. DIAMOND PATTERN 9 GA. WIRE
GATE TO BE STEEL PIPE FRAME 1.90" OD @ 2.72 LBS/FT.GATE FABRIC SAME AS FENCING.
FORK TYPE LATCH. LOCK BY OWNER
STRETCHER BAR W/ 12 GA. GALV. FITTINGS
NOTE:1. ALL FENCING SHALL BE HOT-DIP GALVANIZED.2. GATES SHALL COMPLY W/ ASTM-F900-05.
CHAINLINK GATE POST CHART
SIZE OF OPENING (PER LEAF)
UP TO 6'-0"
OVER 6'-0" TO 13'-0"
OVER 13'-0" TO 18'-0"
OVER 18'-0"
PIPE SIZE AND WEIGHT
2.875" OD, 5.79 LBS PER LIN. FT.
4" OD, 9.10 LBS PER LIN. FT.
6.625" OD, 18.97 LBS PER LIN. FT.
8.625" OD, 24.70 LBS PER LIN. FT.
ALL CHAIN LINK FENCING TO BE
GALVANIZED WITH BLACK VINYL-COATED FINISH, PRIVACY SLATS & RAZORWIRE.
HORIZ BRACE AT BOTH SIDES OF GATE POSTS
REF CHAIN LINK FENCE POST DETAIL
3/8"Ø GALV. ROD W/ TRUSS TIGHTENER
GATE POSTS, REF CHART FOR SIZING
REF. CHART
6'-0",
UP
TO
8'-0"
GA
TE
PO
ST
S
40"
MIN
AT
VINYL MINI MESH CHAIN LINK W/ 6 GA WIRE AND 1/4" MESH
GATE TO BE STEEL PIPE FRAME 1.90" OD @ 2.72 LBS/FT.GATE FABRIC SAME AS FENCING.
KEY CHAIN LINK LOCK SET W/ LEVER, GATE STOP AND KEEPER
STRETCHER BAR W/ 12 GA. GALV. FITTINGS
NOTE:1. ALL FENCING SHALL BE HOT-DIP GALVANIZED.2. GATES SHALL COMPLY W/ ASTM-F900-05.
ALL CHAIN LINK FENCING TO BE
GALVANIZED WITH BLACK VINYL-COATED FINISH, PRIVACY SLATS & RAZORWIRE.
CHAINLINK GATE POST CHART
SIZE OF OPENING (PER LEAF)
UP TO 6'-0"
OVER 6'-0" TO 13'-0"
OVER 13'-0" TO 18'-0"
OVER 18'-0"
PIPE SIZE AND WEIGHT
2.875" OD, 5.79 LBS PER LIN. FT.
4" OD, 9.10 LBS PER LIN. FT.
6.625" OD, 18.97 LBS PER LIN. FT.
8.625" OD, 24.70 LBS PER LIN. FT.
PANIC HARDWARE W/ DOOR PULL LESS DOGGING ON GATE W/ TAMPER-PROOF PLATE BY FENCE FABRICATOR
10" KICKPLATE
BOTH SIDES OF GATE
2'-0"
2"
DE
PT
H O
FC
ON
TA
INE
R
6"
MIN
.
REF. PLANFOR
SPACING
1'-0"MIN.
MULCH
SHRUB BALL REMOVED FROMCONTAINER
PLANTING MIX
EXISTING SOIL
NOTE: TOP SURFACE ELEVATION OF MULCH IS TO BE AT THE FINISH GRADE ELEVATION AND SHOULD NOT BLOCK SITE DRAINIAGE.
OF SIGN TO EDGE OF PAVEMENT
NOT LESS THAN 6'-0" (N.T.S.) FROM EDGE
"ST
OP
SIG
N"
ON
LY
2'-0"
@
(7'-0"
AT
PA
VIN
G O
R P
ED
ES
TR
IAN
MO
VE
ME
NT
)
5'-0"
1'-6"
1'-0"
REF SITE PLAN FOR SIGN CONFIGURATION
NOTE:ALL SIGNS TO HAVE RETROREFLECTIVITY LEVEL AS PER REQUIREMENTS.
NOTE:ALL SIGNS TO BE IN ACCORDANCE WITHIN JURISDICTION OR CITY REQUIREMENTS, WHICHEVER IS MORE STRINGENT.
VISITORPARKING
DRUG FREE - GUN FREESCHOOL ZONE
VIOLATORS WILL FACE FEDERAL PENALTIES
NOTICE SEARCH OF VEHICLESALL VEHICLES ENTERING THIS LOT ARE SUBJECT TO SEARCHUPON ANY REASONABLE SUSPICION THAT THE VEHICLE MAY
CONTAIN DANGEROUS, OR ILLEGAL ITEMS AND/ORSUBSTANCES. SEARCHES WILL BE ACCOMPLISHED BY
SCHOOL EMPLOYEES OR BY LAW ENFORCEMENT OFFICERSACTING AT THE REQUEST OF THE DISTRICT OR AN EMPLOYEE.
STRICTLY PROHIBITED* ALCOHOLIC BEVERAGES* WEAPONS OF ANY TYPE* ILLEGAL SUBSTANCES
* FIREARMS* NO SMOKING OR SMOKELESS TOBACCO IN ANY
SCHOOL BUILDING OR ON ANY SCHOOL GROUNDSIN ACCORDANCE WITH STATE LAW
SIGN 2
VISITORSALL VISITORS MUST REGISTER AT THE MAIN OFFICE.
1'-6"
1'-0"
VIOLATORS SUBJECT TO
FINE AND TOWING
SIGN 3
1'-0"
NO PARKING
SIGN 1
1'-6"
1'-0"
AUTHORIZED PERSONNEL
ONLY
1'-0"
RESTRICTED AREA
RED BACKGROUND
BLACK LETTERS
BLACK LETTERS
WHITE BACKGROUND
RED BACKGROUND
1'-6"
BLACK LETTERS
BLACK LETTERS
WHITE BACKGROUND
NOTE: TOP SURFACE ELEVATION OF MULCH IS TO BE AT THE FINISH GRADE ELEVATION AND SHOULD NOT BLOCK SITE DRAINIAGE.
RUBBER HOSE ATFIRST BRANCHING
TREE WRAP
3 GUY WIRES &TURNBUCKLES
SET TREE ATEXIST GRADE
1" MULCHDO NOT
COVER ROOT FLARE
4" SOIL SAUCERPLANTING SOIL
3 PINE STAKES 2" x 2" x 24"
EXISTING GRADE
REMOVE BURLAP & TIES FROM TOP
OF BALL ONLY
EXISTING SOIL
6"
AS
RE
QD
4"
60°
1'-6" 1'-0" NTS AS REQD 1'-0" NTS 1'-6"
RUBBER HOSE AT FIRST BRANCHING
TREE TRUNK
3 TURNBUCKLES& GUY WIRES
OUTLINE OF TREE PIT
TREE STAKE
TREE BALL
120°
A (20'-0") = CLEAR OPENING
A x 0.5 (REF MANUF)
COUNTERBALANCE LENGTH
B = POST SPACING (A/2 - 11")
PLAN VIEW
ELEVATION VIEW
NTS
NTS
5"
GA
TE
HE
IGH
T
PO
ST
HE
IGH
T
BARBED WIRE AND ARMS
ALL POST SHALL BE 4" OD, U.N.O.
1.04
4
1.04
4
1.04
6
1.04
5
3
1.04
ALL CHAIN LINK FENCING TO BE
GALVANIZED WITH BLACK VINYL-COATED
FINISH, PRIVACY SLATS & RAZORWIRE.
A X 1.5 (REF MANUF)
C = OVERALL WIDTH
GATE OPERATOR
4" O.D. POST
BOTTOM GUIDE BRACKET
UL 325 COMPLIANT WHEEL COVERS
GUIDE WHEEL
CATCHER
4" O.D. POST
COMPANION
SMOOTH LEADING EDGE (NO PROTRUSIONS PER ASTM F 2200)
4'-0"
MIN
(N
.T.S
)
5"
(NT
S)
4" O.D. POST
W4 TRUCK
TRACK
ASTM F 2200 COMPLIANT GAP
PROTECTORS
FABRIC
BARBED WIRE AND ARMS
BEARINGS
W4 TRUCK
HANGER BOLT
GUSSETS
HANGER BRACKET
SHEE
T N
O.
CLAY
COM
B AS
SOCI
ATES
, ARC
HITE
CTS
* 511
3 SO
UTHW
EST
PKW
Y * S
UITE
100
AUST
IN, T
EXAS
787
35 *
WW
W.C
LAYC
OM
B.NE
T
1.04
Man
or, T
exas
MAN
OR
IND
EPEN
DAN
TSC
HO
OL
DIS
TRIC
T
MAN
OR
ISD
JOB
NO
. 220
15
DAT
E: 0
8.15
.202
0
POLI
CE
STAT
ION
REN
OVA
TIO
NIS
SUE:
BID
ISSU
E
08/15/20
SCALE: 1/2" = 1'-0"14
GATE OPERATOR PLAN DTL
SCALE: 1/2" = 1'-0"15
PEDESTAL KEYPAD DETAIL
SCALE: 1/2" = 1'-0"16
EXTERIOR BOLLARD DETAIL
SCALE: 1/4" = 1'-0"8
SECURITY CHAIN LINK FENCE ELEVATION
SCALE: 1/2" = 1'-0"7
SECURITY CHAIN LINK GATE ELEVATION (DOUBLE)
SCALE: 1/2" = 1'-0"9
SECURITY CHAIN LINK GATE ELEVATION (SINGLE)
SCALE: 1/2" = 1'-0"13
SHRUB PLANTING DETAIL
SCALE: 1" = 1'-0"11
SITE SIGNAGE DETAIL
SCALE: 3" = 1'-0"1
SITE SIGNSSCALE: 1/2" = 1'-0"
10TREE PLANTING DETAIL
SCALE: 1/2" = 1'-0"12
TREE STAKING PLAN
SCALE: 1/4" = 1'-0"2
SLIDE CHAIN LINK GATE ELEVATION
SCALE: 1/4" = 1'-0"5
GATE - BOTTOM GUIDE
SCALE: 1/4" = 1'-0"4
GATE - CATCH ASSEMBLY
SCALE: 1/4" = 1'-0"3
GATE - ENLARGED SECTION
SCALE: 1/4" = 1'-0"6
GATE HANGER
...\188-262 GN.dgn 8/14/2020 11:24:50 AM
...\188-262 PAVING GRADING PLAN.dgn 8/14/2020 11:25:48 AM
3'-0"
4"
5"
3'-4"
4'-4"
1C
HEALTH SCIENCEA111
STORAGEA111A
MDFA113
JAN.A114
CNA CLASSROOMA110
ELECTRICALA112 COFF/BRK
A115
MEETINGA107
CORRIDORA100E
CORRIDORA100D
MED. ASSISTANTCLASSROOM
A109
MED. ASSISTANTHEALTHCARE
A108
STORAGEA108A
WOMENA106
MENA105
LOBBYA104C
VESTIBULEA100A
OFFICEA101
OFFICEA102
STORAGEA103A
MECHATRONICS, ELEC.HVAC CLASSROOM
A104
PC TECH CLASSROOMA103
BREAK ROOMA100C STORAGE
A104A
1A 1A
1B
1C
1D
1E1F1G
1S
1J
1K
1Q
1M
1J
1Q
1F
1N1N
1N
1M
1L
1B
8'-1"1T
1P
1R
1R
1Q
1B
1A
3'-0" 11'-5" 3'-0" 3'-4"
1V
1B
1W
1X
VESTIBULEA101
A101A
A113A
EVIDENCEA109
TRAININGA106
PROCESSING/INTERVIEWA105
SHOPA112
CUBICLE OFFICESA103
VESTIBULEA104
A105A
A112A
A109A
A118A
A130A
EXISTING CANOPY ABOVE
REF.
A134A
A133A
D4
D4
D4
D4
D4
R14R14
ALIGN
ALIG
N
ALIGN
ALIG
N
ALIGN
D4
D4
D4
MECHANICAL/ELECTRICAL EQUIPMENT
14'-6"
12'-5"
10'-5"
6'-2" ±
6'-6"
±
4'-7"
3'-0"
5'-3"
A108
9'-2"
7'-8"
8'-0"
16'-3"
D4
D4
19'-3"
4'-0"
3'-0"6'-4" 3'-4"
A104D
REF.
ADMIN. ASSIST.A102
SOFT INTERVIEWA107
OFFICEA108
SEC. DOCS.A110
OFFICESA113
MENSA114
WOMENSA115
STORAGEA116
EXEC. ASSIST.A117
CORRIDORA118
MEETINGA119
COFF/BRKA120
ELECTRICALA121
CORRIDORA122
JAN.A123MDF
A124
STORAGEA125
TRAININGA126
OFFICEA127
P & W COORD.A128
ASST. DIR. HEALTHSERVICES
A130
MENTOR COORD. &GRANT DIR.
A132DIR. HEALTH SERVICES
A133
STORAGEA134
D4
D4
APPLY SECURITY/SAFETY FILM OVER EXISTING GLAZING UP TO FIRST TRANSOM WINDOW, APPLY TO INTERIOR AND EXTERIOR FACES
INSTALL NEW RECESSED KNOX BOX
INSTALL NEW KNOX BOX
NEW PRIVACY FILM ON EXISTING WINDOWS
F2 F2
H2
C2
H2
A106A
A107A
A108A
A110A
A112D
A112C
A112B
3'-0" 11'-5" 3'-0" 3'-4"
D~
5/8" GYP BD
SOUND BATT INSULATION
WD STUDS @ 16" OC, BRACED ABOVE CEILING DIAGONALLY @ 48" OC
(RIGHT NUMBER DENOTES STUD SIZE)'4' = 3 1/2" WD STUDS;'6' = 5 1/2" WD STUDS
DRYWALL / STUD WALL
5/8" GYP BD
WD STUDS @ 16" OC W/ BATT INSULATION WHERE SCHED
FLOORING AS SCHED
BASE AS SCHED
1/2
"
R~
1 HOUR (TO DECK)UL DESIGN NO. 314
(LEFT NUMBER DENOTES HOUR RATING, RIGHT NUMBER DENOTES STUD SIZE)'4' = 3 1/2" WD STUDS;'6' = 5 1/2" WD STUDS
5/8" TYPE 'X' GYP BD
SOUND BATT INSULATION
WD STUDS @ 16" OC, BRACED ABOVE CEILING DIAGONALLY @ 48" OC
SHEE
T N
O.
CLAY
COM
B AS
SOCI
ATES
, ARC
HITE
CTS
* 511
3 SO
UTHW
EST
PKW
Y * S
UITE
100
AUST
IN, T
EXAS
787
35 *
WW
W.C
LAYC
OM
B.NE
T
4.00
Man
or, T
exas
MAN
OR
IND
EPEN
DAN
TSC
HO
OL
DIS
TRIC
T
MAN
OR
ISD
JOB
NO
. 220
15
DAT
E: 0
8.15
.202
0
POLI
CE
STAT
ION
REN
OVA
TIO
NIS
SUE:
BID
ISSU
E
08/15/20
SCALE: 1/8" = 1'-0"1
EXISTING/DEMOLITION PLAN
GENERAL NOTES - DEMO PLAN1. THE CONTRACTOR IS TO PROTECT AND PRESERVE ALL EXISTING IMPROVEMENTS
NOT SCHEDULED TO BE REMOVED, REPAIRED OR ADDED AGAINST ALL DAMAGE. REPAIR AND/OR REPLACE ALL MATERIALS DAMAGED DURING DEMOLITION TO A LIKE NEW CONDITION. ANY DAMAGE DONE SHALL BE REPAIRED TO THE SATISFACTION OF THE OWNER AND THE ARCHITECT.
2. THE CONTRACTOR IS TO VISIT THE SITE OF PROPOSED CONSTRUCTION TO VERIFY EXISTING CONDITIONS AND IS TO NOTIFY THE ARCHITECT OF ANY DISCREPANCIES OR QUESTIONS PRIOR TO THE SUBMISSION OF BID.
3. THE CONTRACTOR IS TO COORDINATE STORAGE OF ALL REMOVED BUILDING COMPONENTS AND EQUIPMENT WITH THE OWNER.
4. ALL INFORMATION REGARDING EXISTING FIELD CONDITIONS, MATERIALS, METHODS OF CONSTRUCTION AND DIMENSIONS SHALL BE OBSERVED, NOTED, AND VERIFIED BY THE CONTRACTOR PRIOR TO ANY CONSTRUCTION OR FABRICATION.
5. WHEN REMOVING MECHANICAL, PLUMBING, AND/OR ELECTRICAL FIXTURES, THE ATTACHED UTILITY LINES ARE TO BE CAPPED BEHIND WALLS, CEILINGS AND/OR BELOW FINISH FLOOR IN A MANNER APPROVED BY THE GOVERNING BUILDING CODES AND LOCAL AUTHORITY. THE AFFECTED WALL/CEILNG/FLOORS ARE TO BE PATCHED AND REPAIRED IN A MANNER TO MATCH THE EXISTING ADJACENT SURFACES.
6. EXISTING ROOMS AND REMODELED EXISTING AREAS WHICH ARE SCHEDULED TO RECEIVE NEW FLOOR FINISHES WILL REQUIRE THE EXISTING FLOOR FINISH TO BE REMOVED PRIOR TO INSTALLING THE NEW FLOORING. THE CONTRACTOR IS TO FIELD VERIFY EACH ROOM PRIOR TO BID IN ORDER TO DETERMINE THE AMOUNT OF REMOVAL OF EXISTING FLOOR FINISHES AND FLOOR PREPARATION.
7. EXISTING ELECTRICAL/DATA/TELEPHONE OUTLETS AND ASSOCIATED WIRING THAT ARE UNCOVERED DURING THE DEMOLITION OF EXISTING WALLS ARE TO BE RELOCATED IN ADJACENT WALLS, UNLESS OTHERWISE NOTED. COORDINATE LOCATIONS WITH ARCHITECT.
8. SALVAGE ALL REMOVED SIGNS, BULLETIN BOARDS, AND MARKER BOARDS, LOCKERS, LIGHT FIXTURES AND EQUIPMENT AND RETURN PER OWNER'S DIRECTION.
9. PATCH ALL "EXISTING TO REMAIN" AREAS/ITEMS WITHIN AREAS OF DEMOLITION WITH FINISHES MATCHING THE ADJACENT FINISHES/CONSTRUCTION.IN ROOMS TO BE PREPARED FOR NEW PAINT FINISH CONTRACTOR TO REMOVE ALL SCREWS, NAILS, AND PATCH ALL EXISTING WALLS AS REQUIRED FOR A "LIKE NEW" SURFACE.
10. CONTRACTOR TO COORDINATE ALL UTILITY SHUT-OFFS, AS NEEDED, WITH OWNER TO PREVENT DISRUPTIONS OF ACTIVITIES BEFORE CONSTRUCTION BEGINS.
11. IF CONTRACTOR OBSERVES POTENTIAL ASBESTOS CONTAINING MATERIALS, THEN VERIFY WITH OWNER REGARDING POSSIBLE REMOVAL. ABATEMENT IS NOT PART OF THIS CONTRACT.
12. IN ALL DEMOLITION WORK CAP ANY AND ALL PLUMBING BELOW FLOOR, OR ABOVE NEW CEILING. PRESERVE PLUMBING THAT WILL BE REUSED IN NEW PLUMBING LAYOUT. TERMINATE ELECTRICAL TO THE NEAREST REMAINING JUNCTION BOX OR REUSE AS DIRECTED IN ELECTRICAL DRAWINGS-REFERENCE MEP FOR ADDITIONAL INFORMATION. REFERENCE STRUCTURAL FOR FLOOR RECESS INFILL, SEE ARCHITECTURAL DRAWINGS FOR NEW PLAN. ALL SLAB PENETRATIONS NOT SHOWN ARE TO BE INFILLED, REFERENCE STRUCTURAL DRAWINGS.
SCALE: 1/8" = 1'-0"2
NEW FLOOR PLAN
ROOM FINISH SCHEDULEROOM
NO. ROOM NAME BASE FLOOR WALLSCEILING
MAT'L NOTES
A101 VESTIBULE B1 F1 W1 - -
A102 ADMIN. ASSIST. B1 F1 W1 C1 -
A103 CUBICLE OFFICES B1 F1 W1 C1 -
A104 VESTIBULE B1 F2 W1 C1 -
A105 PROCESSING/INTERVIEW B1 F2 W1 C1 W/ BATT INSUALTION OVER DROP CEILING
A106 TRAINING B1 F4 W1 C1 W/ BATT INSUALTION OVER DROP CEILING
A107 SOFT INTERVIEW - - W1 - -
A108 OFFICE - - W1 - -
A109 EVIDENCE B1 - W1 C1 W/ BATT INSUALTION OVER DROP CEILING
A110 SEC. DOCS. - - W1 C1 W/ BATT INSUALTION OVER DROP CEILING
A112 SHOP B1 F4 W1 C1 W/ BATT INSUALTION OVER DROP CEILING
A113 OFFICES B1 F2 W1 C1 W/ BATT INSUALTION OVER DROP CEILING
A114 MENS - - W1 - -
A115 WOMENS - - W1 - -
A116 STORAGE - - W1 - -
A117 EXEC. ASSIST. B1 F4 W1 C1 W/ BATT INSUALTION OVER DROP CEILING
A118 CORRIDOR B1 - W1 - -
A119 MEETING - - W1 - -
A120 COFF/BRK - - W1 - -
A121 ELECTRICAL - - W1 - -
A122 CORRIDOR - - W1 - -
A123 JAN. - - W1 - -
A124 MDF - - W1 - -
A125 STORAGE - - W1 - -
A126 TRAINING B1 F4 W1 C1 W/ BATT INSUALTION OVER DROP CEILING
A127 OFFICE B1 F4 W1 C1 W/ BATT INSUALTION OVER DROP CEILING
A128 P & W COORD. B1 F3 W1 C1 W/ BATT INSUALTION OVER DROP CEILING
A130 ASST. DIR. HEALTH SERVICES B1 F3 W1 C1 W/ BATT INSUALTION OVER DROP CEILING
A132 MENTOR COORD. & GRANT DIR. B1 F2 W1 C1 W/ BATT INSUALTION OVER DROP CEILING
A133 DIR. HEALTH SERVICES B1 F2 W1 C1 W/ BATT INSUALTION OVER DROP CEILING
A134 STORAGE B1 F2 W1 C1 -
SCALE: 3" = 1'-0"3
WALL BASE (TYP)
DEMOLITION NOTES SCHEDULENUMBER NOTE
1 DEMOLITION WORK
1A REMOVE PORTION OF WALL TO INSTALL WINDOW AND REPAIR
1B EXISTING UPPER AND LOWER CASEWORK, REMOVE SECTION WHERE NEW WALL IS TO BE BUILT. ADD END CLOSURE PANEL TOCASEWORK. ADD FILLER PANEL AND REWORK MILLWORK AS NEEDED.
1C REMOVE PORTION OF WALL TO INSTALL DOOR AND REPAIR.
1D REMOVE EXISTING DOOR AND SALVAGE FOR REUSE. REFER TO DOOR SCHEDULE.
1E CUT AND CAP EXISTING PNUEMATIC LINES ABOVE THE CEILING. REFER TO MEP DRAWINGS
1F REMOVE EXISTING POWER DISCONNECT. REFER TO ELECTRICAL DRAWINGS.
1G REMOVE/RELOCATE EXISTING POWER AND DATA OUTLETS AS NECESSARY TO ACCOMMODATE NEW FURNITURE LAYOUT.REFER TO THE FF&E PLAN AND ELECTRICAL/TECHNOLOGY DRAWINGS.
1H RELOCATE EXISTING PROJECTOR, SCREEN AND CONTROL PANEL TO ROOM A126.
1J REMOVE EXISTING MARKER BOARD, COORDINATE WITH OWNER FOR RELOCATION.
1K REMOVE EXISTING TACK BOARD, COORDINATE WITH OWNER FOR RELOCATION
1L REMOVE EXISTING VINYL TILE FLOOR FINISH AND BASE. COORDINATE WITH OWNER FOR RELOCATION.
1M REMOVE AND INVENTORY EXISTING PROJECTOR AND CONTROL UNIT FOR REUSE.
1N EXISTING PROJECTOR AND CONTROL UNIT TO REMAIN.
1P EXISTING CARPET AND BASE TO BE REMOVED.
1Q EXISTING VCT TILE TO REMAIN, REMOVE BASE.
1R REMOVE EXISTING CEILING MOUNTED CURTAIN TRACK. RETURN TO OWNER
1S REMOVE AND STORE EXISTING FIRE EXTINGUISHER FOR REUSE.
1T REMOVE INTERIOR SIDE WALL ASSEMBLY. INSTALL NEW SOUND BATT INSULATION AND REPAIR OPENING
1V REMOVE EXISTING DIGITAL CLOCK AND SWITCH, PROVIDE TO OWNER.
1W REMOVE EXISTING WALL MOUNTED KNOX BOX. RETURN TO OWNER. CONTRACTOR TO SAW CUT OR HAMMER OUT EXISTINGBRICK AND REPLACE/TUCK POINT JOINTS AS NEEDED.
1X REMOVE EXISTING COUNTER TOP AND SUPPORTS.
NORTHNORTH
ROOM FINISH LEGENDGENERAL FINISH LEGEND NOTES:1. REF. 7.00 SERIES SHEETS FOR ADDITIONAL FINISH SCOPE INFORMATION.
BASEB1 - 4" RUBBER
WALLSW1 - PAINT
GENERAL NOTES - FLOOR PLAN1. DIMENSIONS ARE MEASURED FROM THE FOLLOWING:
A. FACE OF MASONRY.B. CENTER LINE OF COLUMN OR COORD. LINE BETWEEN COLUMNS.C. FACE OF STUD TO FACE OF STUD.
2. ALL DOORS ARE CAPABLE OF OPENING 180° UNLESS NOTED OTHERWISE (U.N.O.).3. FINISH FLOOR ELEVATIONS ARE 100'-0" U.N.O.4. ALL ANGLES ARE 0°, 45°, OR 90° U.N.O.5. DIMENSIONS SHALL HAVE PRECEDENCE OVER SCALE.6. FIELD VERIFY EXISTING CONDITIONS, NOTIFY ARCHITECT OF ANY DISCREPANCIES
PRIOR TO COMMENCEMENT OF THE WORK.7. PROVIDE CORNER GUARDS AT ALL OUTSIDE CORNERS IN CORRIDORS WITH
PAINTED GYP BD WALLS.
FLOORF1 - CARPETF2 - VCTF3 - SALVAGED CARPET TILE F4 - SALVAGED VCT TILE
CEILINGC1 - 2'X2' SUSP. ACOUSTICAL CEILING
W/ SOUND BATT ABOVE
CONTROL JOINT NOTES
1. INSTALL CONTROL JOINTS IN ALL GYP BD WALLS AT BOTH SIDES OF DOORS.
2. INSTALL CONTROL JOINTS IN ALLGYP BD WALLS AT BOTH SIDES OF WINDOW. (ABOVE AND BELOW)
3. INSTALL CONTROL JOINTS AT ALL WALL INTERSECTIONS, AND ALL FURR DOWN INTERSECTIONS.
5. OTHER LOCATIONS WHERE CONTROL JOINTS ARE REQ'D. THAT ARE NOT DESCRIBED ABOVE IN NOTES 1 THRU 4 ARE SHOWN ON THE PLAN WITH THIS SYMBOL.
(THIS SYMBOL IS NOT SHOWN ATALL REQ'D CONTROL JOINTS).
WALL TYPES BY SYMBOLWALL TYPES & GENERAL NOTES:1. REFER TO DETAILS, SECTIONS, REFLECTED CEILING PLANS & SCHEDULES
FOR FINISHES & ADDN INFO.2. REFER TO SPECIFICATIONS FOR MATERIAL GRADES, TYPES & OTHER INFO.3. REFER TO CODE ANALYSIS PLANS AND REFLECTED CEILING PLANS FOR RATED
WALL AND SOUND WALL LOCATIONS.4. REFER RCP FOR WALL EXTENTS.5. INSULATE AND SEAL SOUND WALL CONNECTIONS AND PENETRATIONS.
REFER TO PARTITION DETAILS FOR ADDITIONAL INFORMATION.6. SEAL RATED WALLS, CONNECTIONS & PENETRATIONS ACCORDING TO UL
ASSEMBLY. REFER TO PARTITION DETAILS FOR ADDITIONAL INFORMATION.
CJ
1st FLOOR100'-0"
3 111 8 9 10752 4 6
10"
4"
1'-0"
7'-4"
1'-0"
4"
1'-0"
4"
1'-0"
6'-0"
"MANOR ISD POLICE
DEPARTMENT" ACROVYN
COLOR LOGO.
5'-0"
3'-0"
CENTER WITH EXISTING SERVICE DESK
11'-0"
EXISTING TV TO REMAIN
SHEE
T N
O.
CLAY
COM
B AS
SOCI
ATES
, ARC
HITE
CTS
* 511
3 SO
UTHW
EST
PKW
Y * S
UITE
100
AUST
IN, T
EXAS
787
35 *
WW
W.C
LAYC
OM
B.NE
T
5.20
Man
or, T
exas
MAN
OR
IND
EPEN
DAN
TSC
HO
OL
DIS
TRIC
T
MAN
OR
ISD
JOB
NO
. 220
15
DAT
E: 0
8.15
.202
0
POLI
CE
STAT
ION
REN
OVA
TIO
NIS
SUE:
BID
ISSU
E
08/15/20
SCALE: 1/4" = 1'-0"1
SOUTH ELEVATION
APPLY SECURITY/SAFETY FILM OVER
EXISTING GLAZING UP TO FIRST
TRANSOM WINDOW, APPLY TO
INTERIOR AND EXTERIOR FACESEXISTING SECURITY
CAMERAS TO REMAIN,
EXISTING SECURITY
CAMERAS TO REMAIN
EXISTING ROOF TO
REMAIN
EXISTING MASONRY
TO REMAIN
INSTALL NEW
RECESSED KNOX BOX
EXISTING MASONRY
TO REMAIN
EXISTING STUCCO
TO REMAIN
EXISTING CARD READER TO REMAIN.
GC TO VERIFY OPERABILITY
SCALE: 1/2" = 1'-0"2
ADMINISTRATIVE ASSISTANT GRAPHIC
NEW "MISD HUMAN SERVICES AND
WELLNESS PROGRAM" SIGNAGE
STUD MOUNTED. CAST ALUMINUM
LETTERS OT MATCH EXISTING
14B
NEW "POLICE STATION" SIGNAGE
STUD MOUNTED. CAST ALUMINUM
LETTERS OT MATCH EXISTING
14B
EXISTING "MANOR ISD"
SIGNANGE TO REMAINAPPLY SECURITY/SAFETY FILM OVER
EXISTING GLAZING UP TO FIRST
TRANSOM WINDOW, APPLY TO
INTERIOR AND EXTERIOR FACES
AS SCHED.
FLUSH
AS
SC
HE
D.
AS
SC
HE
D.
2" 2" AS SCHED. 2"
AS SCHED.
2"
2"
AS
SC
HE
D.
2'-6"
2"
3'-8"
2"
3'-4"
2" 2"
2'-10"
BLINDSBLINDS
A2
3'-4"
2"
VA
RIE
S2"
C2 F2
2"
AS SCHED. 2"
45 MIN. RATED WINDOW ASSEMBLY
2"
3'-8"
2"
3'-4"
2" 2"
2'-10"
BLINDS
H2
1'-6"LATCH SIDE OF DOOR
ROOM SIGN - PROVIDE BACKER PANEL WHEN LOCATED ON GLASS (SAME COLOR AS FACE) WHEN NOT LOCATED ON GLASS INSTALL ONE FASTNER AT EACH CORNER OF SIGN.
PROVIDE ONE TACTILE INTERIOR ROOM SIGN AT EACH FIRE ALARMPULL STATION INDICATING "EXIT". CENTER SIGN ON PULL STATION @60" A.F.F. WITH 4" CLEAR SPACE AROUND ALL PERIMETERS OF THE SIGN
48"
MIN
. A
.F.F
. T
O B
AS
ELIN
EO
F L
OW
ES
T T
AC
TIL
E C
HA
RA
CT
ER
ROOM SIGN TEXT
CL
60"
MA
X. A
.F.F
. T
O B
AS
ELIN
EO
F H
IGH
ES
T T
AC
TIL
E C
HA
RA
CT
ER
CLEAR FLOOR SPACE OF 18"x18", CENTERED ON SIGN
BATT INSULATIONWHERE SCHED.
HM FRAME W/ WD STUD ANCHORS
SEALANT - CONT ALL SIDES DOOR AS SCHED. TO SWING 180°
1/2
"F
INIS
HE
DW
ALL T
HIC
KN
ES
S1/2
"
2"
NOTE: REF. WALL TYPES FOR FINISH WALL THICKNESS.
2X WD. STUD &2X CRIPPLE STUD
5/8" GYP BD (U.N.O.)
DOOR AS SCHED.
NOTE: REF. WALL TYPES FOR FINISH WALL THICKNESS.
2"
1/2"
FINISHEDWALL THICKNESS 1/2"
HM FRAME
METAL STUDS @ 16" O.C.
BATT INSULATION WHERE SCHED.
2 - 2X_ WD. HEADERW/ 1/2" PLYWD. BLK'G.
GLAZINGAPPLIED HM STOP (TYP)
PROVIDE WALL BRACING UNDER WINDOW WHERE REQ'D.
HM FRAME
PLU
S 1
"
WA
LL T
HK
2"DOOR AS SCHED.
TO SWING 180°
BATT INSULATIONWHERE SCHED.
HM FRAME W/ ANCHORS
SEALANT - CONT ALL SIDES GLAZING
NOTE: REF. WALL TYPES FOR FINISH WALL THICKNESS.
1/2
"F
INIS
HE
DW
ALL T
HIC
KN
ES
S1/2
"
2"
HM FRAME W/ WD STUD ANCHORS2X WD. STUD &
2X CRIPPLE STUD
HM FRAME
STUDS @ 16" O.C.
GLAZING
5/8" GYP BD
HM FRAME / MULLION BEYOND
NOTE: REF. WALL TYPES FOR FINISH WALL THICKNESS.
1/2"
FINISHEDWALL THICKNESS 1/2"
2"
BATT INSULATION WHERE SCHED.
HM FRAME
METAL STUDS @ 16" O.C.
5/8" GYP BD (U.N.O.)
GLAZING
BATT INSULATION WHERE SCHED.
NOTE: REF. WALL TYPES FOR FINISH WALL THICKNESS.
2"
1/2"
FINISHEDWALL THICKNESS 1/2"
2 - 2X_ WD. HEADERW/ 1/2" PLYWD. BLK'G.
PLU
S 1
"
WA
LL T
HIC
KN
ES
S
2"
PROVIDE WALL BRACING UNDER WINDOW WHERE REQ'D.
HM FRAME
GLAZINGAPPLIED HM STOP (TYP) GLAZING
HM FRAME AS SCHED.
WALL AS SCHED.
GLAZING
MINI BLINDS -ATTACH TO HM FRAME
INT HM WINDOW HEAD - STUD WALL
ROOM SIDE
THICKNESS
FINISHED WALL
NOTE:MOUNT 48" TO TOP OF HANDLE.
16" O.C. (INSUL AS REQ'D.)
DOUBLE STUDS AROUND CAB
WOOD STUDS @
CONTINUOUS SEALANT BEAD
FINISH & WALL TYPE AS SCHED.
6" RECESSED FIRE EXTINGUISHER CABINET
5/8" GYP BD BOTH SIDES (TWO LAYERS AS REQ'D.)
HOLD STUDS AND GYP BD APART 1/8" W/ SPACERS
WHILE WALL IS BUILT -THEN REMOVE SPACERS.
CERAMIC TILE OVER BACKER BOARD
BED AND FLOAT FIN. LINE
METAL "L" JOINT TRIM
SEALANT FLUSH W/ FIN. WALL
GYP BD ONWD STUDS1/8"
1/8" WIDE SEALANT JOINT -COLOR TO MATCH GROUT (DO NOT GROUT JOINT.)
2X WD. STUDS
1/8" WIDE SEALANT JOINT -COLOR TO MATCH GROUT (DO NOT GROUT JOINT.)
HM DOOR / WINDOW FRAME ABOVE / BELOW
METAL "L JOINT TRIM
HOLD STUDS AND GYP BD APART 1/8" W/ SPACERS
WHILE WALL IS BUILT -THEN REMOVE SPACERS.
NOTE: PROVIDE SEALANT AND / OR SAFING TO MAINTAIN RATING OF WALL OR MATERIAL NEEDED FOR SOUND TRANSMISSION AS PER STC RATINGS.
NOTE:SAME DETAIL TO OCCUR ABOVE & BELOWWINDOW FRAMES.
1/8"
GYP BD ON MTL STUDS
CERAMIC TILE OVER BACKER BOARD
BED AND FLOAT FIN. LINE
2X WD. STUD &2X CRIPPLE STUD
BED AND FLOATFINISH LINE
SEALANT FLUSH W/ FINISHED WALL
METAL EDGE TRIM (BACK TO BACK)
GYP BD ON WD STUDS
STUDS
1/8"
HOLD STUDS AND GYP BD APART 1/8" W/ SPACERS
WHILE WALL IS BUILT -THEN REMOVE SPACERS.
4" U.N.O.
Y
DO X
Z DO X
Y
WALL OR CABINET LINE WHERE OCCURS
APPROACH X = 18" MINY = 60" MIN
REQD CLEARANCE
AP
PR
OA
CH
X =
24"
MIN
Y =
48"
MIN
OR
54"
MIN
IF
D
OO
R
HA
S
CLO
SE
R
AP
PR
OA
CH
X =
24"
MIN
Y =
42"
MIN
OR
48"
MIN
IF
D
OO
R
HA
S
CLO
SE
R
REQD CLEARANCE
PULL SIDE
PUSH SIDE
LATCH SIDEHINGE SIDE
DOOR
AP
PR
OA
CH
X =
36"
MIN
Y =
60"
MIN
OR
X =
42"
MIN
Y =
54"
MIN
APPROACH
AP
PR
OA
CH
X =
0Y
= 4
2"
MIN
OR
48"
MIN
IF
DO
OR
HA
S
BO
TH
LA
TC
H &
CLO
SE
RZ
= 2
2"
MIN
X = 0" OR 12" MIN IF DOOR HAS BOTH LATCH & CLOSER
Y = 48" MIN
NOTE: OPENING MUST BE AT LEAST 32" CLEAR BETWEEN THE STOP AND THE DOOR LEAF WHEN THE DOOR IS OPEN TO 90°.
SHEE
T N
O.
CLAY
COM
B AS
SOCI
ATES
, ARC
HITE
CTS
* 511
3 SO
UTHW
EST
PKW
Y * S
UITE
100
AUST
IN, T
EXAS
787
35 *
WW
W.C
LAYC
OM
B.NE
T
5.60
Man
or, T
exas
MAN
OR
IND
EPEN
DAN
TSC
HO
OL
DIS
TRIC
T
MAN
OR
ISD
JOB
NO
. 220
15
DAT
E: 0
8.15
.202
0
POLI
CE
STAT
ION
REN
OVA
TIO
NIS
SUE:
BID
ISSU
E
08/15/20
SCALE: 1/2" = 1'-0"
DOOR TYPES
SCALE: 1/4" = 1'-0"
HM FRAME TYPES
GENERAL NOTES - DOOR SCHEDULE* SEE HARDWARE SPECIFICATIONS FOR ADDITIONAL INFORMATION.
1. FINISH TO BE AS SCHEDULED OR AS SELECTED BY ARCHITECT.
2. AT OVERHEAD COILING/COUNTER DOORS, ALLOW FOR ADDITIONAL SLATS BEYOND FINISH OPENING HEIGHT TO BOTTOM OF DOOR HOUSING.
3. VERIFY ELECTRIC MOTOR LOCATIONS WITH OWNER.
GLAZING SCHEDULEEXTERIOR
REFER TO EXT. ELEVATIONS
INTERIORTEMPERED GLASS(ALL INTERIOR DOORS AND WINDOWS)
GENERAL NOTES1. ALL HOLLOW METAL FRAMES TO BE PAINTED.
2. ALL INTERIOR & EXTERIOR DOORS TO HAVE ROOM SIGNAGE.
3. DIMENSIONS SHOWN ON THIS SCHEDULE ARE APPROXIMATE. FINAL DIMENSIONS ARE TO BE MEASURED AT JOB SITE.
4. PROVIDE HORIZONTAL LOUVER BLINDS AT ALL WINDOWS. INSTALL BLINDS FLUSH WITH AND BETWEEN WINDOW FRAMES WHERE POSSIBLE.
SCALE: 1/2" = 1'-0"1
DOOR SIGNAGE DETAIL
DOOR SCHEDULEDOOR
NO.ROOM NAME
DOOR FRAMETYPE
FIRERATING
NOTESSIZE TYPE MATERIAL
A101A VESTIBULE PR 36 x 84 ALUM PANEL ALUM -
A104D CUBICLE OFFICES 36 x 84 FLUSH WOOD A2
A105A BREAK ROOM 36 x 84 FLUSH WOOD A2
A106A TRAINING 36 x 84 EXISTING EXISTING -
A107A ADMIN. ASSIST. 36 x 84 EXISTING EXISTING -
A108 OFFICE 30 x 84 FLUSH WOOD A2
A108A ADMIN. ASSIST. 36 x 84 EXISTING EXISTING -
A109A EVIDENCE 36 x 84 FLUSH WOOD A2
A110A SEC. DOCS. 36 x 84 EXISTING EXISTING -
A112A TRAINING 36 x 84 FLUSH WOOD A2
A112B SHOP PR 30 x 84 EXISTING EXISTING -
A112C SHOP PR 30 x 84 EXISTING EXISTING -
A112D SHOP PR 30 x 84 EXISTING EXISTING -
A113A OFFICES 36 x 84 FLUSH WOOD A2
A118A CORRIDOR 36 x 84 FLUSH WOOD A2 20 MIN.
A130A P & W COORD. 36 x 84 FLUSH WOOD L2
A133A EXEC. ASSIST. 36 x 84 FLUSH WOOD A2
A134A STORAGE 36 x 84 FLUSH WOOD A2
SCALE: 3" = 1'-0"3
HM DOOR JAMB @ STUD - INT
SCALE: 3" = 1'-0"4
HM DOOR HEAD @ STUD - INT
SCALE: 3" = 1'-0"5
HM DOOR JAMB @ SIDELITE - INT
SCALE: 3" = 1'-0"8
HM WINDOW JAMB @ STUD - INT
SCALE: 3" = 1'-0"9
HM WINDOW SILL @ STUD - INT
SCALE: 3" = 1'-0"10
HM WINDOW HEAD @ STUD - INT
SCALE: 3" = 1'-0"6
HM VERT MULLION - INT
SCALE: 3" = 1'-0"7
BLINDS DETAIL @ HM FRAMESCALE: 1 1/2" = 1'-0"
11FIRE EXTINGUISHER CABINET
SCALE: 6" = 1'-0"13
CONTROL JOINT DETAIL (TYP)
SCALE: 6" = 1'-0"12
CONTROL JOINT DETAIL @ OPENING
SCALE: 12" = 1'-0"14
INT WALL CONTROL JOINT DETAIL
SCALE: 1/2" = 1'-0"2
DOOR CLEARANCES
VESTIBULE
1 HR 1 HR 1 HR
1 HR 1 HR 1 HR
1 H
R1
HR
1 H
R
SUSPENDED ACOUSTICAL CEILING 2' X 2' GRID
GYP BD CEILING
EXISTING AREAS
REFLECTED CEILING PLAN LEGEND
WALL ASSEMBLY BUILT TO DECK
1 HOUR FIRE RATED UL #314(BUILT TO DECK)
6'-6"
+/-
5A
5B
5B
5C
5F
5F
5A
5A
5A
5A
5A
5A
5B
5B
5B
5B
5B
5B
5B
5B
5B
5B
5C
5C
6'-2" ±
5E
5F
5C
MED. ASSISTANT
CLASSROOM
A109
CORRIDORA100D
MEETINGA107
ELECTRICALA112
COFF/BRKA115
WOMENA106
MENA105
MDFA113
STORAGEA111A
JAN.A114
CNA CLASSROOMA110
HEALTH SCIENCEA111
MED. ASSISTANT
HEALTHCARE
A108
STORAGEA108A
LOBBYA104C
OFFICEA101
OFFICEA102
PC TECH CLASSROOMA103
MECHATRONICS, ELEC.
HVAC CLASSROOM
A104
BREAK ROOMA100C
VESTIBULEA100A
STORAGEA103A
5C
5A
5C
5C
18'-2"
+/-
4'-0" +/-
6'-2" +/-
10'-8" +/-
10'-10"
+/-
12'-9 1/2" ± 4'-0"
6C
6A
6A
6B
6C
6C
6D
6E
6F
6C
6C
6A
6G
JAN.A123
MDFA124
STORAGEA125
ELECTRICALA121
COFF/BRKA120
MEETINGA119
WOMENSA115
MENSA114
TRAININGA126
OFFICEA127
P & W COORD.A128
MENTOR COORD. &
GRANT DIR.
A132
EXEC. ASSIST.A117
DIR. HEALTH SERVICESA133
STORAGEA116
VESTIBULEA101
ADMIN. ASSIST.A102
OFFICEA108
SOFT INTERVIEWA107
SEC. DOCS.A110
EVIDENCEA109
OFFICESA113
TRAININGA106
STORAGEA134
SHOPA112
CUBICLE OFFICESA103
CORRIDORA118
PROCESSING/INTERVIEWA105
5
6.00
STUD WALLREF WALL TYPES
CLG AS SCHED
2X4 PURLINNS
2X4 STRUT BRACING @" 48" O.C.
EXIST. CLG. JOIST / TRUSSES
NEW BATT INSULATION AS SCHED.
NEW BATT INSULATION AS SCHED.
STUD WALLREF WALL TYPES
CLG AS SCHED
2X4 PURLINNS
2X4 STRUT BRACING @" 48" O.C.
EXIST. CLG. JOIST / TRUSSES
CLG AS SCHEDNEW BATT INSULATION AS SCHED.
NEW BATT INSULATION AS SCHED.
SUSPENDEDACOUSTICAL LAY-INCEILING SYSTEM.
NEW COMPASSO TRIM , MATCH EXISTING HEIGHT
EXISTING
MATCH
EXISTING
MATCH
SHEE
T N
O.
CLAY
COM
B AS
SOCI
ATES
, ARC
HITE
CTS
* 511
3 SO
UTHW
EST
PKW
Y * S
UITE
100
AUST
IN, T
EXAS
787
35 *
WW
W.C
LAYC
OM
B.NE
T
6.00
Man
or, T
exas
MAN
OR
IND
EPEN
DAN
TSC
HO
OL
DIS
TRIC
T
MAN
OR
ISD
JOB
NO
. 220
15
DAT
E: 0
8.15
.202
0
POLI
CE
STAT
ION
REN
OVA
TIO
NIS
SUE:
BID
ISSU
E
08/15/20
SCALE: 1/8" = 1'-0"1
RCP DEMOLITIONSCALE: 1/8" = 1'-0"
2NEW RCP
REFLECTED CEILING PLAN NOTES SCHEDULENUMBER NOTE
5 CEILING DEMOLITION
5A REMOVE EXISTING LAY-IN CEILINGS AND SUSPENSION SYSTEM TO THE EXTENTS SHOWN. FIELD VERIFY ALL CEILING DIMENSIONS AND REMOVE TO THE NEAREST WHOLE TILE TO ACCOMODATE NEW PARTITIONS.
5B EXISTING CEILING TO REMAIN. CEILING TO BE PROTECTED AND BRACED DURING DEMOLITION. CONTRACTOR TO REPAIR ANY DAMAGED AREAS TO LIKE NEW CONDITION AS WELL AS REPLACE ALL STAINED CEILING TILES TO MATCH EXIST.
5C RELOCATE EXISTING LIGHTING FIXTURE.
5D SALVAGE EXISTING LIGHTING FIXTURES FOR RE-USE. COORDINATE W/OWNER FOR RE-USE OR STORAGE.
5E DEMOLISH EXISTING GYP BD CEILING TO THE EXTENTS SHOWN.
5F SALVAGE LIGHT FOR RELOCATION.
5G SALVAGE PENDANT LIGHT FOR RE-USE.
6 CEILING WORK
6A RELOCATED LIGHTING FIXTURE. REFER TO ELECTRICAL DRAWINGS FOR MORE INFORMATION.
6B INSTALL SALVAGED 2' X 4' LIGHTING FIXTURE. REFER TO ELECTRICAL DRAWINGS FOR MORE INFORATION.
6C INSTALL NEW CEILING TILES TO MATCH EXISTING IN KIND. MODYF TEGULAR SUSPENDED CEILING IN A103 AS SHOWN ON PLANS W/ NEW PERIMETER TRIM.
6D INSTALL SALVAGED LIGHT. CENTER IN ROOM. GC TO VERIFY HEIGHT DOES NOT INTERFERE W/DOOR SWING.
6E INFILL CEILING W/NEW GYP BD. TAPE AND MUD. PAINT TO MATCH EXISTING.
6F RE-INSTALL EXISTING SALVAGED PEMNDANT LIGHT FIXTURE.
6G INSTALL SUPPLY LOUVER. REFER TO MECHANICAL DRAWINGS FOR MORE INFORMATION.
6H INSTALL EXHAUST FAN. REFER TO MECHANICAL DRAWINGS FOR MORE INFORMATION.
SCALE: 1/2" = 1'-0"3
WALL TO BOTTOM OF FRAMINGSCALE: 1/2" = 1'-0"
4WALL TO BOTTOM OF DECK
SCALE: 1 1/2" = 1'-0"5
ACOUSTICAL CLG W/ COMPASSO TRIM
RE
F.
REF.
TRAININGA106
EXISTING CANOPY ABOVE
7.30 5
7.30
9
VESTIBULEA101
EVIDENCEA109
SHOPA112
CUBICLE OFFICESA103
VESTIBULEA104
ADMIN. ASSIST.A102
SOFT INTERVIEWA107
OFFICEA108
SEC. DOCS.A110
OFFICESA113
MENSA114
WOMENSA115
STORAGEA116
EXEC. ASSIST.A117
CORRIDORA118
MEETINGA119
COFF/BRKA120
ELECTRICALA121
CORRIDORA122
JAN.A123
MDFA124
STORAGEA125
TRAININGA126
P & W COORD.A128
ASST. DIR. HEALTH
SERVICES
A130
MENTOR COORD. &
GRANT DIR.
A132
DIR. HEALTH SERVICESA133
STORAGEA134
PROCESSING/INTERVIEWA105
3B 3E
3C
3G
3B
3B3F
12B
2M3B
10A
3D 3D
10A
3F
3H
3K
3M
10B
3J
3L
3K
3J
10B
10A
3N
11A
11A
11B
11B
3A
12A
1B
1B
2B 2B
2B
2B2B
OFFICEA127
2E
SHEE
T N
O.
CLAY
COM
B AS
SOCI
ATES
, ARC
HITE
CTS
* 511
3 SO
UTHW
EST
PKW
Y * S
UITE
100
AUST
IN, T
EXAS
787
35 *
WW
W.C
LAYC
OM
B.NE
T
7.00
Man
or, T
exas
MAN
OR
IND
EPEN
DAN
TSC
HO
OL
DIS
TRIC
T
MAN
OR
ISD
JOB
NO
. 220
15
DAT
E: 0
8.15
.202
0
POLI
CE
STAT
ION
REN
OVA
TIO
NIS
SUE:
BID
ISSU
E
08/15/20
SCALE: 1/8" = 1'-0"1
FLOOR PLAN - FIXTURE AND FINISH PLAN NORTH
FIXTURE SCHEDULE
TAG # DESCRIPTIONWIDTH x HEIGHT x
DEPTH MFG - MODEL # REMARKS
2 - CABINETS & MILLWORK
2E METAL SHELVING 110"Wx12"D 2 REF DTL 12/7.30
2M ADMIN MAIL SLOTS 72"Wx72"Hx14"D - REF DTL 9,10/7.30
3 - VISUAL BOARDS
3A 2' TACK BOARD 24"W x 24"H - --
3B 8' MARKER BOARD 96"W x 48"H - --
3C 12' MARKER BOARD 144"W x 48"H - --
3D 16' MARKER BOARD 192"W x 48"H - --
3E EXISTING 8' TACK BOARD -- - EXISTING TO REMAIN
3F EXISTING 8' MARKER BOARD -- - EXISTING TO REMAIN
3G EXISTING 12' MARKER BOARD -- - EXISTING TO REMAIN
3H FLAT SCREEN - 40" -- -- OFCI
3J FLAT SCREEN - 27" -- -- OFCI
3K FLAT SCREEN - 60" -- -- OFCI
3L EXISTING FLAT SCREEN - 40" -- -- EXISTING TO REMAIN
3M EXIST FLAT SCREEN - 60" -- -- EXISTING TO REMAIN
3N EXISTING FLAT SCREEN - 27" -- -- EXISTING TO REMAIN
10 - MISCELLANEOUS
10A FIRE EXTINGUISHER CABINET -- REF DTL 11/5.60
10B REFRIGERATOR -- -- OFCI
10N PRIVACY CURTAIN & TRACK - - --
11 - PROJECTORS & SCREENS
11A EXISTING VIDEO PROJECTOR AND MOUNT - - EXISTING TO REMAIN
11B VIDEO PROJECTOR AND MOUNT - - OFCI
12 - LOCKERS
12A SENTINEL EVIDENCE LOCKER 36"W X 82"H X 24"D #04AA-NPT --
12B LOCKERS (DBL TIERED) 12"Wx18"Dx36"H -- --
GENERAL NOTES - COLOR SCHEDULE1. THE GENERAL CONTRACTOR IS TO SUBMIT ALL MATERIALS, SAMPLES AND
DRAWINGS IN ACCORDANCE WITH THE SPECIFICATIONS PRIOR TO INSTALLATION.2. ALL CAULK AND SEALANTS ARE TO MATCH THE SURFACE ON WHICH THEY OCCUR. 3. REFER TO SECTION 09 91 00 FOR PAINTING REQUIREMENTS. 4. PAINT ALL AIR REGISTERS OR GRILLS THE COLOR OF THE SURFACE ON WHICH
THEY OCCUR. 5. ALL HANDRAILS AND EXPOSED STEEL SHAPES ARE TO PAINTED PER TNEMEC
SPECIFICATIONS. 6. ALL UNDESIGNATED WALLS ARE TO BE PAINTED MARK '8A'.7. PAINT ALL EXPOSED EXTERIOR GAS PIPING TO MATCH ADJACENT FINISHES,
WHEN EXPOSED TO VIEW.8. PAINT ALL EXPOSED INTERIOR GAS PIPING '8B'.9. PAINT ALL EXPOSED INTERIOR WATER PIPING '8B'.10. PAINT ALL EXPOSED POWER CONDUIT THE COLOR OF THE SURFACE ON WHICH
THEY OCCUR.11. ALL PLASTIC LAMINATE COUNTER TOPS & BACKSPLASHES TO '15B'.12. ALL WOOD DOORS TO BE [P-LAM / STAINED WOOD] '15A'.13. PROVIDE SOUND BATTS ABOVE ALL CEILING TILE OVER ALL AREAS.14. ALL BOLLARDS ARE TO BE 'SAFETY YELLOW'.15. ALL INTERIOR AND EXTERIOR HOLLOW METAL FRAMES ARE TO BE MARK '8A'.16. VERIFY ALL GRAPHICS AND SIGNAGE WITH ARCHITECT BEFORE INSTALLATION
AND PAINTING.17. UTILIZE TILE GROUT '5A' AT ALL WALL SURFACES UNLESS NOTED OTHERWISE.18. CAULK THE PERIMETER OF ALL HOLLOW METAL DOORS AND FRAMES, LOCATED
WITHIN INTERIOR MASONRY WALLS.19. ALL INTERIOR AND EXTERIOR EXPOSED STEEL SHAPES ARE TO BE MARK 8B'
(U.N.O.).20. ALL INTERIOR AND EXTERIOR HANDRAILS ARE TO BE MARK '8B' (U.N.O.).
1A
1A
1A
2A
2A
2A
2A
2A
2A
COLOR SCHEDULECOLOR
NUMBER MATERIAL MANUFACTURER TYPE COLOR REMARKS
FLOOR
1A CARPET PATCRAFT CUBE & COLOR STAR ANISE - 24 X 24 BRICKPATTERN
XP BACKING SYSTEM
1B CARPET -- -- -- SALVAGED EXISTING CARPET TILE
2A VCT ARMSTRONG IMPERIAL TEXTURE STANDARDEXCELON
#51932 LUNAR BLUE USE 5A GROUT
2B VCT -- -- -- SALVAGED EXISTING VCT TILE
5A GROUT ---- ---- CHARCOAL GREY SEE GEN. COLOR NOTES
WALLS
8A PAINT SHERWIN WILLIAMS -- SW 9150 ENDLESS SEA DOOR FRAMES
8B PAINT SHERWIN WILLIAMS -- SW 9144 MOONMIST
BASE
10A RUBBER ROPPE COVE BASE # 40 FAWN USE INTERIOR & EXTERIOR CORNERS
MISC
14A GRAPHIC BANNER ACROVYN BY DESIGN WALL COVERING BLUE/RED W/SILVER LETTERING REFER TO MEDALLION ELEVATION ON 2/5.20
14B CAST ALUMINUM LETTERS GEMINI, INC. TWENTIETH CENTURY FONT 1'-0" -- MATCH EXISTING LETTERING
15A P. LAM WILSONART PREMIUM 7935K-07 SHAKER SHERRY BASE - CASEWORK
15B P. LAM WILSONART STANDARD LAMINATE 4876-38 SHEER MESH TOP - CASEWORK
BASE CABINET - DOUBLE DOORS
& DRAWERS
UPPER CABINET -DOUBLE DOORS
REF ELEV
REF ELEV
CO
UN
TE
R H
EIG
HT
RE
F E
LE
V
7.30
1
REF. CASEWORK ELEVATIONS & CASEWORK DETAILS FOR ADDITIONAL INFORMATION.
7.30
3
7.30
2
ELEVATION SECTION
TIMBERLINE CB-256 SERIES DOUBLE DOOR LOCK
TIMBERLINESP-257BRACKET
TIMBERLINESP-185 BRACKET
WIRE PULL HANDLES (TYP)
NOTE: DIMENSIONS ARE APPROXIMATE. VERIFY HARDWARE AND MOUNTINGWITH TIMBERLINE.
NOTE: PROVIDE CABINET LOCK FOR EACH CABINET (TYP).
(96 m
m)
3 3
/4"
4"
2"
1/8" GAP
2"
1/8" GAP 1"
3/4
"1 7
/8"
2 5
/8"
TIMBERLINE CB-256 SERIES DOUBLE DOOR LOCK
11/16" OFFSET
1 7
/8"
3/4
"
SP-185 STRIKE PLATE
2 5
/8"
WIRE PULL HANDLES (TYP)
TIMBERLINE CB-251 SERIES DOUBLE DOOR LOCK
(96 m
m)
3 3
/4"
4"
2"
1/8" GAP
2"
1 7
/8"
3/4
"
1/8" GAP 1" 11/16" OFFSET
3/4
"1 7
/8"
ELEVATION SECTION
NOTE: DIMENSIONS AREAPPROXIMATE. VERIFYHARDWARE AND MOUNTINGWITH TIMBERLINE.
NOTE: PROVIDE CABINET LOCK FOR EACH CABINET (TYP).
TIMBERLINE SP-185 STRIKE PLATE
TIMBERLINE SP-185 STRIKE PLATE
TIMBERLINE SP-257 BRACKET
TIMBERLINE CB-251 SERIES DOUBLE DOOR LOCK
2 5
/8"
2 5
/8"
SP-185 STRIKE PLATE
TIMBERLINE CB-280SERIES SINGLE LOCK
3 3/4" (96 mm) WIRE PULL HANDLES (TYPICAL)- CENTERED ON DRAWERS LESS THAN 8" HIGH AND4" FROM TOP ON DRAWERS GREATER THAN 8" HIGH.
TIMBERLINE CB-280SERIES SINGLE LOCK
1"
1/2
"G
AP
1/4
"
1"
1/2
"1/4
" G
AP
9/32" SETBACK
13/1
6"
3/8
" T
HR
OW
ELEVATION SECTION
TIMBERLINE SP-185 STRIKE PLATE
NOTE: DIMENSIONS ARE APPROXIMATE. VERIFY HARDWARE AND MOUNTINGWITH TIMBERLINE.
NOTE: PROVIDE CABINET LOCK FOR EACH CABINET (TYP).
1 3
/4"
1 3
/4"
SP
-185 S
TR
IKE
PLA
TE
TIMBERLINE CB-290SERIES SINGLE LOCK
4"
(96 m
m)
3 3
/4"
ELEVATION PLAN
WIRE PULL HANDLE (TYP)
1/4" GAP
2"
1/4" GAP
1 3/4"
FIXED 3/4" CABINET DIVIDER BEYOND
TIMBERLINE CB-290 SERIES SINGLE LOCK
3/4
"1 7
/8"
TIMBERLINESP-185 STRIKE PLATE
NOTE: DIMENSIONS ARE APPROXIMATE. VERIFY HARDWARE AND MOUNTINGWITH TIMBERLINE.
NOTE: PROVIDE CABINET LOCK FOR EACH CABINET (TYP).
2 5
/8"
3/4" 3/4" 1 1/8"
1/4" GAP
1 3/4"
9/3
2"
SE
TB
AC
K
3/4" 3/4" 1 1/8"
THROW3/8"
13/16"
2'-6"
1'-4"
4"
2'-10"
FILLER 2'-6" 2'-6" 2'-6"
FILLER 2'-6" 2'-6" 2'-6"
6
7.30
7
7.30
REF. BY DISTRICT
7'-7"
BASE AS SCHED.
P.LAM COVERED CABINET DOOR
P.LAM COVERED FILLER PANEL AS NEEDED
P.LAM COVERED COUNTER TOP
BACKSPLASH
P.LAM COVERED FILLER PANEL AS NEEDED
P.LAM COVERED CABINET DOORS
15A
15A
15A
15A
15B
10A
WATER LINE TO BE INSTALLED W/ RECESSED BOX UNIT.
PLAM COVERED
BOT, SIDES AND BACK
PLAM COVERED - REF
SPECS
SURFACES TO BE
NOTE: ALL EXPOSED
SPLASH, TOP AND EDGEPLAM COVERED
PLAM COVEREDDOOR AND DRAWER FRONT
W/ PVC EDGES
PLAM COVERED
W/ PVC EDGES
ADJUSTABLE SHELF
DRAWER - REF SPECS
BASE AS SPEC
2'-0"
1 1
/4"
3/8
"6"
1/8
"
3 1
/2"
3" 4"
3/8
"
RE
F E
LE
V4"
SOLID DOOR AS SPECIFIED
BOTTOM AS SPECIFIED
SIDES AS SPECIFIED
BACK AS SPECIFIED
BRACKETS AS SPECHOLES FOR SHELF
ATTACH CABINETS TOWALLS AS SPECIFIED
TOP AS SPECIFIED
ADJUSTABLE SHELVES ASSPECIFIED - QUANTITY AS SCHED
WHERE NOTEDGYP BD FURR DOWN
HT AFF PER CAB MFGR2x6 BLKG IN WALL
RE
F E
LE
VA
TIO
NR
EF
ELE
V
1'-1"
10
7.30
1"
V.I.F. EXIST WALL DIMENSION
6'-0" ±1" FILLER
35 SLOT MAILBOX UNIT
RE
F S
EC
TIO
N
6'-2" ±
BASE AS SCHED.
P.LAM COVERED CABINET DOOR
P.LAM COVERED FILLER PANEL AS NEEDED
15A
15A
10A
P-LAM COVERED BOT, SIDES, PARTITIONS SHELVES AND BACK W/ PVC EDGES
15A
NOTE: ALL EXPOSEDSURFACES TO BEP-LAM COVERED.
GROUND
P-LAM COVERED DOOR FRONTW/ PVC EDGES
ADJUSTABLE SHELF W/ PVC EDGES
GROUND
BASE AS SCHED.
FIXED SHELVESAND PARTITIONS
P-LAM COVERED BOT, SIDES, PARTITIONS SHELVES AND BACK W/ PVC EDGES
2'-10"
8 E
Q S
PA
CE
S =
3'-0"
1 1
/4"
1/4
"2'-4 1
/2"
4"
1'-1"
3"
5'-10"
1'-2"
1'-0 3
/4"
7'-0"
PROVIDE SHELVING, WHERE OCCURS -REF. ELEVATIONS
2'-1"
2'-0"
5'-1"
TILE BASE AT TILE FLOOR -RUBBER BASE AT VCT FLOOR
LOCKERS (SHOWN DASHED)
2x BLOCKING CONT - RECESS 3/4" (PAINT FLAT BLACK)
2x BLOCKING WOOD BLOCKING
CONT. ZEE BASE AND INTERMEDIATE SUPPORTS
REF SCHED
4"
RE
F S
CH
ED
.
3/4
"
5'-0"
AF
F
P-LAM COVERED 1" THICK SHELF- SCREW TO BRACKETS
12" METAL SHELF BRACKET @ 32" O.C.
WALL AS SCHED.
CONTINUOUS 2x4 WOOD BLOCKING
1'-0"
SHEE
T N
O.
CLAY
COM
B AS
SOCI
ATES
, ARC
HITE
CTS
* 511
3 SO
UTHW
EST
PKW
Y * S
UITE
100
AUST
IN, T
EXAS
787
35 *
WW
W.C
LAYC
OM
B.NE
T
7.30
Man
or, T
exas
MAN
OR
IND
EPEN
DAN
TSC
HO
OL
DIS
TRIC
T
MAN
OR
ISD
JOB
NO
. 220
15
DAT
E: 0
8.15
.202
0
POLI
CE
STAT
ION
REN
OVA
TIO
NIS
SUE:
BID
ISSU
E
08/15/20
SCALE: 3/4" = 1'-0"11
CABINET LOCK ELEVATIONS
SCALE: 6" = 1'-0"3
CABINET LOCK @ UPPER CABINET WITHOUT CENTER DIVIDER
SCALE: 6" = 1'-0"2
CABINET LOCK @ BASE CABINET WITHOUT CENTER DIVIDER
SCALE: 6" = 1'-0"1
CABINET LOCK @ DRAWER
SCALE: 6" = 1'-0"4
CABINET LOCK @ SINGLE DOOR UPPER CABINET
SCALE: 1/2" = 1'-0"5
CASEWORK ELEVATION TRAINING A106
SCALE: 1 1/2" = 1'-0"6
BASE CAB - 1 DRAWER AND DOOR
SCALE: 1 1/2" = 1'-0"7
WALL CAB WITH SOLID DOORS
SCALE: 1/2" = 1'-0"9
BUILT-IN MAILBOX UNIT
SCALE: 1 1/2" = 1'-0"10
MAILBOX SECTION - TEACHERS WRK
SCALE: 1 1/2" = 1'-0"8
LOCKER DETAIL
SCALE: 1 1/2" = 1'-0"12
SHELF DETAIL
J
JJ
S4-SS4-S
S1
IV III
S4
S4
S4S4
2
1
3
2
HAR-7
HAR-7HAR-7
HAR-7HAR-7
HAR-7HAR-7
S3HAR-7
44
REFER TO PLANS FORQUANTITY AND TYPE OFLUMINAIRES LAND POLES
SCHEDULE 40 PVC
REFERENCE STRUCTURALDRAWINGS FOR BASEINFORMATION
NOTE:
PROVIDE A 30" SETBACKBETWEEN THE CONCRETEFOUNDATION PERIMETERAND THE ADJACENT CURBOR ROADWAY
HANDHOLE
BASE COVER
1" CHAMFER
#6 BARE COPPERGROUND WIRE
3/4" ∅ X 10'-0" LONGCOPPER GROUND ROD
CADWELDCONNECTION
ANCHOR BASE AND BOLTSPERMANUFACTURER'SREQUIREMENTS
30"
NOTE:
30"
CONCRETEFOUNDATION
NOTE:
GROUT VOID BETWEENBASE FLANGE ANDTOP OF CONCRETE.PROVIDE WEEPHOLETHROUGH GROUT AT BASEOF POLE
FINISHEDGRADE
24"
30"
SHEE
T N
O.
CLAY
COM
B AS
SOCI
ATES
, ARC
HITE
CTS
* 660
0 LB
J FR
EEW
AY *
SUIT
E 20
0DA
LLAS
, TEX
AS 7
5240
* W
WW
.CLA
YCO
MB.
NET
08/1
5/20
20
08.01
Man
or, T
exas
MAN
OR
IND
EPEN
DAN
TSC
HO
OL
DIS
TRIC
T
MAN
OR
ISD
JOB
NO
. 220
125
DAT
E: 0
8.15
.202
0
POLI
CE
STAT
ION
ISSU
E: B
ID S
ET
REFERENCE SCALE IN INCHES
0 1 2 3
PROJECT #
IMEG CORP RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS, TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR DATA ARE THE EXCLUSIVE PROPERTY OF IMEG CORP AND SHALL NOT BE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN APPROVAL AND PARTICIPATION OF IMEG CORP. © 2020 IMEG CORP.
14755 PRESTON ROAD, SUITE 845DALLAS, TX 75254972.239.6100 FAX: 972.239.6102www.imegcorp.com
TBPE# F-18632
20002811.00
NO R
HT
3/32" = 1'-0"
SITE PLAN - MEP1
GENERAL NOTES
1. NEW SITE LIGHTING SHALL BE CIRCUITED TO EXISTING CIRCUIT HAR-7. CONNECT NEW SITE LIGHTING TO EXISTING TIMECLOCK CONTROLS.
DEMOLITION GENERAL NOTES:
1. (3) EXISTING SITE LIGHT POLES AND ASSOCIATED POLE BASES TO BE DEMOLISHED. CONTRACTOR SHALL ALSO REMOVE POLES THAT HAVE ALREADY BEEN DEMOLISHED AND STORED ON SITE.
2. CONTRACTOR MAY RE-USE EXISTING CONDUIT FOR SITE LIGHTING AS HIS OWN DISCRETION. ROUTING OF CONDUIT UNKNOWN.
NO SCALE
POLE BASE DETAIL2
NOTES BY SYMBOL " "#
1. EXISTING PEDESTAL MOUNTED 400A SERVICE ENTRANCE DISCONNECT SWITCH.
2. WEATHERPROOF JUNCTION BOXES FOR SLIDING GATE CONTROL WIRING. FURNISH AND INSTALL 3/4" EMPTY CONDUIT BETWEEN JUNCTION BOXES FOR CONTROL WIRING. COORDINATE JUNCTION BOX LOCATION AND CONDUIT REQUIREMENTS WITH GATE INSTALLER.
3. WEATHERPROOF JUNCTION BOX FOR CONNECTION TO MOTORIZED GATE. CONNECT TO NEW 20A/3P CIRCUIT BREAKER (MATCH EXISTING) TO BE INSTALLED IN EXISTING PANEL 'HAR' WITH (3)#12,#12G-3/4"C. VERIFY ELECTRICAL REQUIREMENTS WITH GATE INSTALLER AND MAKE ALL FINAL CONNECTIONS.
4. TYPE S4H SHIELD SHALL BE INSTALLED ON SIDE INDICATED.
H
C
C2
48
" M
AX
.
20" MAX.
44
" M
AX
.
20"-25" MAX.
48
" M
AX
.
15
" M
IN. 48
" M
AX
.
46
" M
AX
.
10" MAX. 10"-24" MAX.
ADA GUIDELINES - FRONT ACCESS
ADA STANDARDS FOR ACCESSIBLE DESIGN
INSTALL ABOVE COUNTER DEVICE AT 44" ABOVE FINISHED FLOOR.
INSTALL ABOVE COUNTER DEVICE AT 40" ABOVE FINISHED FLOOR.
INSTALL DEVICE AT 18" ABOVE FINISHED FLOOR.
ADA GUIDELINES - SIDE ACCESS
INSTALL DEVICE AT 44" ABOVE FINISHED FLOOR.
INSTALL DEVICE AT 42" ABOVE FINISHED FLOOR.
NTD: DELETE THIS ITEM IF NOT REQUIRED BY PROJECT MANAGER
1. PIPE DRAIN LINES FROM EQUIPMENT TO NEAREST FLOOR DRAIN.2. INSTALL ALL REFRIGERANT LIQUID AND SUCTION PIPING SIZED PER EQUIPMENT
MANUFACTURER RECOMMENDATIONS.3. ALL DOMESTIC WATER PIPING SHALL BE TYPE L COPPER PIPING WITH SOLDERED OR
MECHANICAL PRESS FIT CONNECTIONS.4. ALL CONDENSATE PIPING SHALL BE COPPER DMV OR TYPE M WITH SOLDERED
CONNECTIONS.
PIPING GENERAL NOTES:
1. AFTER CONSTRUCTION ACTIVITIES ARE COMPLETE, TESTING, ADJUSTING (TAB) AND BALANCING CONTRACTOR SHALL REBALANCE OUTSIDE AIR UNIT AS REQUIRED TO ACHIEVE THE NEW AIRFLOW VALUES SHOWN ON THE CONSTRUCTION DRAWINGS.
2. AREAS SERVED BY THIS EQUIPMENT WHICH WERE NOT RENOVATED SHALL BE RE-BALANCED TO THE AIRFLOW RATES MEASURED BEFORE THE RENOVATION OCCURRED (REFER TO THE FINAL PRE- DEMOLITION REPORT).
3. IF DUCT TRAVERSE LOCATION AS MARKED ON THE DRAWINGS IS INACCESSIBLE FOR MEASUREMENT, THE TAB CONTRACTOR SHALL PERFORM THE TRAVERSE AT AN ALTERNATE LOCATION OR SHALL TAKE MULTIPLE DUCT TRAVERSES AND/OR GRILLE READINGS AS REQUIRED TO DETERMINE THE FLOW RATE. IN THE EVENT TRAVERSES ARE TAKEN AT AN ALTERNATE LOCATION(S), TAB CONTRACTOR SHALL INCLUDE A DRAWING THAT SHOWS THE LOCATIONS WHERE THE ACTUAL MEASUREMENTS WERE TAKEN.
4. A DUCT STATIC PRESSURE READING SHALL BE TAKEN AT EACH LOCATION WHERE A DUCT TRAVERSE READING IS TAKEN AND SHALL BE INCLUDED IN THE FINAL POST-CONSTRUCTION TAB REPORT.
5. TAB CONTRACTOR SHALL COMPILE AND SUBMIT COPIES OF THE FINAL POST-CONSTRUCTION TAB REPORT AS REQUIRED BY SECTION 23 05 93.
6. THE FINAL POST CONSTRUCTION REPORT SHALL INCLUDE ALL ITEMS REQUIRED IN THE SPECIFICATIONS.
TAB POST-CONSTRUCTION NOTES:
MECHANICAL GENERAL NOTES:THESE NOTES APPLY TO ALL MECHANICAL SHEETS AND TRADES, INCLUDING BUT NOT LIMITED TO, FIRE PROTECTION, PLUMBING, VENTILATION, PIPING AND TEMPERATURE CONTROL.
1. DRAWINGS SHOWING LOCATIONS OF EQUIPMENT, DUCTWORK, PIPING, ETC. ARE DIAGRAMMATIC AND MAY NOT ALWAYS REFLECT EXACT INSTALLATION CONDITIONS. DRAWINGS SHOW THE GENERAL ARRANGEMENT OF DUCTWORK, PIPING, EQUIPMENT, ETC., AND MAY NOT INCLUDE ALL OFFSETS AND FITTINGS REQUIRED FOR COMPLETE INSTALLATION. THE DRAWINGS SHALL BE FOLLOWED AS CLOSELY AS ACTUAL BUILDING CONSTRUCTION AND THE WORK OF OTHERS WILL PERMIT.
2. DO NOT SCALE DRAWINGS. VERIFY ALL DIMENSIONS AND CLEARANCES FROM ARCHITECTURAL, STRUCTURAL, SUBMITTALS, AND OTHER APPROPRIATE DRAWINGS OR PHYSICALLY AT SITE. REVIEW ALL DRAWINGS, INCLUDING THOSE OF OTHER TRADES.
3. COORDINATE ALL WORK WITH ALL OTHER TRADES PRIOR TO INSTALLATION TO PROVIDE CLEARANCES REQUIRED FOR OPERATION, MAINTENANCE, CODE COMPLIANCE, AND TO VERIFY NON-INTERFERENCE WITH OTHER WORK. DO NOT FABRICATE PRIOR TO VERIFICATION OF NECESSARY CLEARANCES FOR ALL TRADES. BRING ANY INTERFERENCES OR CONFLICTS TO THE ATTENTION OF THE ARCHITECT/ENGINEER BEFORE PROCEEDING WITH FABRICATION OR EQUIPMENT ORDERS.
4. REVIEW SPACE REQUIREMENTS OF EQUIPMENT SPECIFIED OR SUBSTITUTED AND MAKE REASONABLE ACCOMMODATIONS IN LAYOUT AND POSITIONING TO PROVIDE PROPER ACCESS.
5. ANY CHANGES REQUIRED TO ELIMINATE CONFLICTS OR THAT RESULT FROM A FAILURE TO COORDINATE SHALL BE MADE BY THE CONTRACTOR WITHOUT ADDITIONAL COST OR EXPENSE TO OTHERS.
6. EACH CONTRACTOR IS RESPONSIBLE FOR ALL COSTS ASSOCIATED WITH ELECTRICAL CHANGES REQUIRED FOR EQUIPMENT PROPOSED THAT DIFFERS FROM THE BASIS OF DESIGN.
7. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN, ELECTRICAL, TECHNOLOGY AUDIO/VISUAL, AND OTHER MECHANICAL PLANS FOR EXACT LOCATIONS OF ALL CEILING MOUNTED DEVICES, OTHER THAN SPRINKLERS.
8. EACH CONTRACTOR IS RESPONSIBLE FOR DAMAGE CAUSED BY THEIR ACTIONS TO WALLS, FLOORS, CEILINGS, AND ROOFS. THE CONTRACTOR WHOSE WORK CAUSES DAMAGE IS RESPONSIBLE FOR PATCHING TO MATCH ORIGINAL CONSTRUCTION, FIRE RATING, AND FINISH.
9. IN AREAS WITH DRYWALL CEILINGS COORDINATE LOCATIONS OF ACCESS PANELS WITH THE GC FOR ACCESS TO VALVES, DUCTWORK ACCESSORIES, DAMPERS, ETC. COORDINATE PANEL TYPE AND COLOR WITH ARCHITECT. NOTIFY THE GC OF THE REQUIRED ACCESS PANELS PRIOR TO BIDDING.
10. SEAL ALL FLOOR, WALL, AND ROOF PENETRATIONS AIRTIGHT WHERE CONDUITS, PIPING, AND DUCTS PENETRATE. PENETRATIONS THROUGH EXTERIOR WALLS AND ROOF SHALL BE SEALED AIRTIGHT WITH WATERPROOFING MATERIALS RECOMMENDED BY MANUFACTURER FOR OUTDOOR USE.
11. CAULK ALL PIPE AND DUCT PENETRATIONS OF FULL HEIGHT NON-FIRE RATED WALL, PARTITION, FLOOR, AND ROOF ASSEMBLIES. THIS IS ESSENTIAL TO PREVENT NOISE TRANSMISSION FROM ONE ROOM TO ANOTHER AND TO PROVIDE THE DESIRED NC LEVELS WITHIN ROOMS.
12. WHERE PIPES AND DUCTS ARE SHOWN TO PENETRATE FLOORS, PROVIDE SLEEVED OPENINGS WITH THE TOP EDGE RAISED ABOVE FLOOR SURFACE IN ACCORDANCE WITH ALL RELEVANT SPEC SECTIONS. SEAL SLEEVE PERIMETER TO BE WATERTIGHT.
13. EQUIPMENT SIZES AND SERVICE CLEARANCE REQUIREMENTS VARY AMONG DIFFERENT MANUFACTURERS. CONSULT APPROVED SHOP DRAWINGS FOR EQUIPMENT SIZES AND REQUIRED SERVICE CLEARANCES. COORDINATE WITH LAYOUT OF EQUIPMENT PADS, PIPING, DUCTWORK, ETC.
14. DO NOT BLOCK TUBE PULL OR EQUIPMENT SERVICE CLEARANCES. 15. MAINTAIN MINIMUM 3'-6” CLEARANCE IN FRONT OF ALL ELECTRICAL PANELS, MOTOR
STARTERS, SWITCHES, AND DISCONNECTS.16. PROVIDE CONCRETE EQUIPMENT PAD FOR ALL FLOOR MOUNTED EQUIPMENT. PAD SHALL
EXTEND MINIMUM 6” BEYOND ALL SIDES OF EQUIPMENT.17. DO NOT SUPPORT EQUIPMENT, PIPING, OR DUCTWORK FROM METAL DECKING OR OTHER
NON-STRUCTURAL BUILDING ELEMENTS. ANCHORS EMBEDDED IN CONCRETE SHALL BE CRACKED CONCRETE APPROVED IN ACCORDANCE WITH SPECIFICATIONS.
MECHANICAL RENOVATION NOTES:THESE NOTES APPLY TO ALL MECHANICAL SHEETS AND TRADES, INCLUDING BUT NOT LIMITED TO, FIRE PROTECTION, PLUMBING, VENTILATION, PIPING AND TEMPERATURE CONTROL.
1. EXISTING CONDITIONS ARE SHOWN BASED ON INFORMATION OBTAINED FROM FIELD SURVEYS, EXISTING BUILDING DOCUMENTS, AND STAFF. VERIFY EXISTING CONDITIONS AND REPORT ANY CONFLICTS BEFORE PROCEEDING.
2. NOT ALL EXISTING DUCTWORK AND PIPING IS SHOWN. VERIFY EXISTING CONDITIONS BEFORE STARTING WORK. NOTIFY ENGINEER OF ANY CONFLICTS WITH NEW WORK.
3. FIELD VERIFY THE AVAILABLE CLEARANCES FOR DUCTWORK AND PIPING BEFORE FABRICATION. RISES AND DROPS MAY BE NECESSARY BECAUSE OF EXISTING FIELD CONDITIONS.
4. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR CUTTING, REMOVAL AND PATCHING OF ROOFS, WALLS, AND FLOORS ASSOCIATED WITH WORK BY ALL CONTRACTORS. CONTRACTORS SHALL NOTIFY THE GC OF AFFECTED AREAS PRIOR TO BIDDING
5. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR REMOVAL AND REPLACEMENT OF CEILINGS, CEILING TILES, AND CEILING GRIDS ASSOCIATED WITH AREAS OF WORK BY ALL CONTRACTORS. NOTIFY THE GENERAL CONTRACTOR OF AFFECTED AREAS PRIOR TO BIDDING.
6. WHERE EXISTING MECHANICAL SYSTEMS ARE LOCATED IN AREAS THAT CONFLICT WITH NEW EQUIPMENT, PIPING, OR DUCTWORK TO BE INSTALLED, EACH CONTRACTOR SHALL EITHER ARRANGE NEW EQUIPMENT, PIPING, OR DUCTWORK IN SUCH A FASHION THAT IT DOES NOT CONFLICT WITH EXISTING SYSTEMS, OR REWORK EXISTING MECHANICAL SYSTEMS TO ALLOW FOR INSTALLATION OF NEW EQUIPMENT, PIPING, OR DUCTWORK.
7. PROVIDE TEMPORARY CONNECTIONS TO MAINTAIN EXISTING SYSTEMS IN SERVICE DURING CONSTRUCTION. MAINTAIN ACCESS TO EXISTING MECHANICAL INSTALLATIONS THAT REMAIN ACTIVE.
8. OBTAIN PERMISSION FROM OWNER BEFORE SHUTTING DOWN ANY SYSTEM FOR ANY REASON. MAINTAIN SERVICE TO ALL COMPONENTS THAT ARE TO REMAIN UNTIL NEW SYSTEMS ARE INSTALLED.
9. MAINTAIN EXISTING SYSTEM IN SERVICE UNTIL NEW SYSTEM IS COMPLETE AND READY FOR TIE IN AND SWITCHOVER. DRAIN SYSTEM ONLY TO MAKE SWITCHOVERS AND CONNECTIONS. OBTAIN PERMISSION FROM OWNER BEFORE PARTIALLY OR COMPLETELY DRAINING SYSTEM. MAKE CHANGEOVER TO NEW SYSTEMS WITH MINIMUM OUTAGE.
CONTROL VALVE (TWO-WAY)
PITCH PIPE IN DIRECTION
DIELECTRIC CONNECTION
UNION/FLANGE
BALANCING VALVE (NUMBER INDICATES GPM)
PIPE CAP
PIPE DOWN
PIPE UP OR UP/DOWN
DIRECTION OF FLOW IN PIPE
NEW CONNECTION
SHUTOFF VALVE NORMALLY OPEN
SHUTOFF VALVE NORMALLY CLOSED
THROTTLING VALVE
AUTOMATIC BALANCING VALVE
MIXING VALVE
CONTROL VALVE (THREE-WAY)
SOLENOID VALVE
CHECK VALVE
SAFETY/RELIEF VALVE
PRESSURE REDUCING VALVE (LIQUID/GAS)
PRESSURE REDUCING VALVE (STEAM)
TRIPLE DUTY VALVE (ANGLE TYPE)
TRIPLE DUTY VALVE (IN-LINE TYPE)
VACUUM BREAKER
"WYE" - STRAINER
"WYE" - STRAINER W/SHUTOFF VALVE AND HOSE CONNECTION WITH CAP
BASKET STRAINER
FLEXIBLE CONNECTION
PRESSURE/TEMPERATURE TEST PLUG
REDUCER - REFERENCE SPECIFICATIONFOR CONCENTRIC/ECCENTRIC AND FOT/FOB
SUCTION DIFFUSER WITH SUPPORT FOOT
AUTOMATIC AIR VENT
MANUAL AIR VENT
DRAIN VALVE WITH HOSE CONNECTION AND CAP
TT-*
STEAM TRAP (REFER TO SCHEDULE)
T-*F&T STEAM TRAP (REFER TO SCHEDULE)
T-*INVERTED BUCKET STEAM TRAP (REFER TO SCHEDULE)
ALIGNMENT GUIDE
PIPE ANCHOR
EXPANSION JOINT#.#" IS THE EXPANSION TRAVEL INCHES
BOILER BLOW DOWNBD
BOILER FEED WATERBF
CHILLED BEAM RETURNCBR
HEATING/CHILLED WATER RETURNHCR
HEATING/CHILLED WATER SUPPLYHCS
CONDENSER WATER RETURNCR
CONDENSER WATER SUPPLYCS
CLEAN STEAM - NUMBER INDICATES PRESSURE IN PSIG.CS15
CHILLED WATER RETURNCWR
CHILLED WATER SUPPLYCWS
NATURAL GASG
GLYCOL WATER RETURNGWR
GLYCOL WATER SUPPLYGWS
REFRIGERANT HOT GASHG
HIGH PRESSURE CONDENSATEHPC
HEATING WATER RETURNHWR
HEATING WATER SUPPLYHWS
REFRIGERANT LIQUIDLIQ
LOW PRESSURE CONDENSATELPC
OIL RETURNOR
OIL SUPPLYOS
PUMPED CONDENSATEPC
PUMPED DISCHARGEPD
REHEAT WATER RETURNRWR
REHEAT WATER SUPPLYRWS
REFRIGERANT SUCTIONSUC
SAFETY RELIEF VENTSV
HIGH PRESSURE STEAMHPS
LOW PRESSURE STEAMLPS
DRAINDPP
LOW PRESSURE CLEAN STEAMLCS
LOOP WATER RETURNLWR
LOOP WATER SUPPLYLWS
GAS REGULATOR VENTGV
LAB VACUUMVAC
MEDICAL VACUUMMV
METERM
PUMP
STATIC SWITCH
PRESSURE GAUGE (FURNISHED WITH BALL VALVE)P
DIFFERENTIAL PRESSURE SENSOR
PRESSURE SENSOR (FURNISHED WITH BALL VALVE)P
FLOW METERFM
FLOW SWITCHF
FS FLOW SENSOR
MECHANICAL SYMBOL LIST
SYMBOL: DESCRIPTION:
NOT ALL SYMBOLS MAY APPLY.
OCCUPANCY SENSORO
HUMIDISTAT SENSOR
CARBON MONOXIDE SENSOR
CARBON DIOXIDE SENSOR
H HUMIDISTAT / SENSOR
TEMPERATURE SENSOR WITH WELLT
THERMOMETER WITH WELL (DIAL TYPE)T
THERMOMETER WITH WELL (FILLED TYPE)
DIRECTION OF AIR FLOW
FLEXIBLE DUCT
MANUAL VOLUME DAMPER
RISE IN DIRECTION OF AIR FLOWR
DUCT CAP
DROP IN DIRECTION OF AIR FLOWD
DUCT DOWN
DUCT UP
SUPPLY/OUTSIDE AIR DUCT SECTION
RETURN AIR DUCT SECTION
EXHAUST/RELIEF AIR DUCT SECTION
4-WAY DIFFUSER WITH BLANKOFF IN ONE DIRECTION
SD-16/115
AIR TERMINAL PROPERTIES SYMBOLNECK SIZE/CFM
TERMINAL AIR BOX (REFER TO SCHEDULE)###
### TERMINAL AIR BOX w/REHEAT COIL (REFER TO SCHEDULE)
HUMIDIFIERH
OPPOSED BLADE DAMPER (REFER TO SCHEDULE)
PARALLEL BLADE DAMPER (REFER TO SCHEDULE)
DIFFERENTIAL PRESSURE SENSOR
PRESSURE SENSOR/MONITORP
PRESSURE SENSOR (DUCT MOUNTED)P
THERMOSTAT/SENSORT
TEMPERATURE SENSORT
THERMOSTAT/SENSOR WITH HEAVY DUTY ENCLOSURET
MECHANICAL SYMBOL LIST
SYMBOL: DESCRIPTION:
AIRFLOW MEASUREMENT SYMBOLXX - AHU SYMBOLY - SEQUENTIAL NUMBER
XX-Y
NOT ALL SYMBOLS MAY APPLY.
FAN POWERED TERMINAL AIR BOX w/REHEAT COIL (REFER TO SCHEDULE)
SP
BACKFLOW PREVENTER
EJ-#(#.#")
CHILLED BEAM SUPPLYCBS
COMPRESSED AIRCA
RADIANT COOLING RETURNRCR
RADIANT COOLING SUPPLYRCS
PLAN OR DETAIL NUMBER
PLAN OR DETAIL NAME
PLAN OR DETAIL SCALE
DETAIL REFERRED TO BY SECTION CUT
SHEET DETAIL IS LOCATED ON
NAME
1VIEW NAME1/8" = 1'-0"
1
M101
14
32
T101
SIMDETAIL REFERRED TO BY ELEVATION
SHEET DETAIL IS LOCATED ON
INDICATES SIMILAR DETAIL REFERENCED IN MULTIPLE LOCATIONS
SIM
INDICATES SIMILAR DETAIL REFERENCED IN MULTIPLE LOCATIONS
LEVEL NAME
10' - 0" HEIGHT ABOVE PROJECT 0' - 0"
1 INDICATES NOTE USED TO DESCRIBE ADDITIONAL INFORMATION ABOUT WORK REQUIRED, SPECIFIC TO THE SHEET AND/OR DETAIL
NO R HT
INDICATES DIRECTION OF TRUE NORTH
VIEW KEY
NEW WORK BY THIS CONTRACTOR (DARK SOLID LINE)
NEW WORK UNDERFLOOR OR UNDERGROUND BY THIS CONTRACTOR (DARK LONG DASHED LINE)
NEW WORK BY OTHERS AND/OR EXISTING TO REMAIN (LIGHT SOLID LINE)
EXISTING TO BE REMOVED BY THIS CONTRACTOR(DARK SHORT DASHED LINE)
'TAG'-E TAGS WITH DASH 'E' INDICATES THE REFERENCED OBJECT IS EXISTING
TAG-1 UNDERLINED TEXT INDICATES ADDITIONAL INFORMATION CAN BE FOUND ELSEWHERE IN A SCHEDULE, MATERIAL LIST, OR SYMBOL LIST
LINE TYPE AND TAG KEY:
MECHANICAL ABBREVIATION KEY
ABBR: DESCRIPTION:
DIFFERENTIAL PRESSURE GAUGE (RANGE)DPG (0-2")
DIFFERENTIAL PRESSURE SWITCHDPS
AD ACCESS DOOR
ABOVE FINISHED FLOORAFF
NC NEW CONNECTION
NOT IN CONTRACTNIC
CFSD CONTROL/FIRE/SMOKE DAMPER
EA EXHAUST/RELIEF AIR
FD FIRE DAMPER
FOB FLAT ON BOTTOM
FOT FLAT ON TOP
FSD FIRE/SMOKE DAMPER
MA MIXED AIR
OA OUTSIDE AIR
RA RETURN AIR
SA SUPPLY AIR
SD SMOKE DAMPER
TRANSFER DUCTTD
UC-1 DOOR UNDERCUT BY OTHERS (1" TYPICAL)
ECFSD EXISTING CONTROL FIRE SMOKE DAMPER
EFD EXISTING FIRE DAMPER
EFSD EXISTING FIRE SMOKE DAMPER
ESD EXISTING SMOKE DAMPER
TERMINAL AIR BOXTAB
TYPICALTYP
UNO UNLESS NOTED OTHERWISE
NORMALLY CLOSEDN.C.
NORMALLY OPENN.O.
PRESSURE SWITCHPS
MIXING VALVEMV
ELECTRICAL TO PNEUMATIC VALVEEP
CO CLEANOUT
C COMMON
SCCR SHORT CIRCUIT CURRENT RATING
SHEE
T N
O.
CLAY
COM
B AS
SOCI
ATES
, ARC
HITE
CTS
* 660
0 LB
J FR
EEW
AY *
SUIT
E 20
0DA
LLAS
, TEX
AS 7
5240
* W
WW
.CLA
YCO
MB.
NET
08/1
5/20
20
08.02
Man
or, T
exas
MAN
OR
IND
EPEN
DAN
TSC
HO
OL
DIS
TRIC
T
MAN
OR
ISD
JOB
NO
. 220
125
DAT
E: 0
8.15
.202
0
POLI
CE
STAT
ION
ISSU
E: B
ID S
ET
MECHANICAL SHEET INDEX08.01 SITE PLAN - MEP
08.02 MECHANICAL COVERSHEET
08.03 DEMOLITION PLAN-MECHANICAL & FLOOR PLAN-MECHANICAL & PLUMBING
08.04 MECHANICAL SCHEDULES & DETAILS
GRAND TOTAL: 4
REFERENCE SCALE IN INCHES
0 1 2 3
PROJECT #
IMEG CORP RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS, TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR DATA ARE THE EXCLUSIVE PROPERTY OF IMEG CORP AND SHALL NOT BE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN APPROVAL AND PARTICIPATION OF IMEG CORP. © 2020 IMEG CORP.
14755 PRESTON ROAD, SUITE 845DALLAS, TX 75254972.239.6100 FAX: 972.239.6102www.imegcorp.com
TBPE# F-18632
20002811.00
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
C-1-111-A
C-1-111-B
C-1-110-B
C-1-110-A
C-1-108-A
C-1-108-B
C-2-100C-A
C-2-104-A
C-2-104-B
12x12 TD
12x12 TD
CD-1
6/50
CD-E
10/200
CD-E
8/150
CD-1
6/75
CD-1
6/65
CD-1
6/30
CD-1
6/50CD-E
10/205
CD-E
10/190
CD-1
6/50
CD-E
10/180
EF-E
23
3
3
3
3
C-2-A105
4
RG-1
RG-1
RG-1
RG-1
BS-1
BS-2
BS-3
BS-4
7
5
7
7
7
7
7
7
BS-2.1BS-1.2
BS-1.1
7
8
8
9
O/A UNIT-E
11
11
1110
10
11
10
10
11
10
12x12 TD
RG-1
RG-1
3/4
"D
EXISTING
CONDENSATE
5
C-2-100C-B
10
12 12
12
12
14
12
12
12
12
12
12 12
3/4"D
O/A-CU-E
VRF-CU-2-E
VRF-CU-1-E
1/2
"CW
1"CW EXISTING
13
A128P & W COORD.
A130
ASST. DIR.HEALTH
SERVICES
A127
HEALTHSCIENCE
A126TRAINING
A125STORAGE
A124MDF
A123JAN.
A132
MENTORCOORD. &
GRANT DIR.
A117EXEC. ASSIST.
A133
BECKY'SOFFICE
A102ADMIN. ASSIST.
A103
CUBICLEOFFICES
A105PROCESSING/INTERVIEW
A134STORAGE
A106TRAINING
A107
SOFTINTERVIEW
A108
CHEIF'SOFFICE
A110SEC. DOCS.
A109EVIDENCE
A113OFFICES
A118CORRIDOR
A119MEETING
A121ELECTRICAL
A120COFF/BRK
A115WOMEN
A114MEN
A100CBREAK ROOM
A112SHOP
A102ADMIN. ASSIST.
1
5
6
6
5
C-1-108-B
C-1-110-B
6
6
6 6
6 6
6
6
C-1-108-A
C-1-110-A
C-1-111-A C-1-111-B
C-2-100C-A
C-2-100C-B
C-2-104-A
C-2-104-B
BS-3
BS-4
BS-1
BS-2
VRF-CU-2-E
VRF-CU-1-E
O/A-CU-E
C-2-103-A
C-2-103-B
15
14
SHEE
T N
O.
CLAY
COM
B AS
SOCI
ATES
, ARC
HITE
CTS
* 660
0 LB
J FR
EEW
AY *
SUIT
E 20
0DA
LLAS
, TEX
AS 7
5240
* W
WW
.CLA
YCO
MB.
NET
08/1
5/20
20
08.03
Man
or, T
exas
MAN
OR
IND
EPEN
DAN
TSC
HO
OL
DIS
TRIC
T
MAN
OR
ISD
JOB
NO
. 220
125
DAT
E: 0
8.15
.202
0
POLI
CE
STAT
ION
ISSU
E: B
ID S
ET
NO R
HT
1/8" = 1'-0"
FLOOR PLAN - MECHANICAL & PLUMBING2
REFERENCE SCALE IN INCHES
0 1 2 3
PROJECT #
IMEG CORP RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS, TO THIS
DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR DATA ARE
THE EXCLUSIVE PROPERTY OF IMEG CORP AND SHALL NOT BE USED OR
REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN
APPROVAL AND PARTICIPATION OF IMEG CORP. © 2020 IMEG CORP.
14755 PRESTON ROAD, SUITE 845
DALLAS, TX 75254
972.239.6100 FAX: 972.239.6102www.imegcorp.com
TBPE# F-18632
20002811.00
NO R
HT
1/8" = 1'-0"
DEMOLITION PLAN - MECHANICAL1
1. REFER TO GENERAL NOTES ON SHEET 08.02.
2. EXISTING MECHANICAL EQUIPMENT AND
SYSTEMS NOT BEING REMOVED OR
COMMISSIONED IS SHOWN FOR REFERENCE
ONLY. NOT ALL EXISTING SYSTEMS AND
EQUIPMENT IS SHOWN.
3. REFRIGERANT PIPING NOT SHOWN ON PLANS
DUE TO EXACT ROUTING NOT BEING KNOWN.
CONTRACTOR TO FIELD VERIFY REFRIGERANT
ROUTING TO DETERMINE SCOPE OF
DEMOLITION. PIPING CAN BE REUSED AS LONG
AS SIZE IS ACCEPTABLE TO VRF
MANUFACTURER AND INTEGRITY INTACT.
4. CONTRACTOR TO CHECK ALL REFRIGERANT
PIPING AND CONDENSATE PIPING INTEGRITY.
FIX ANY AND ALL LEAKS OR OTHER PROBLEMS.
5. FURNISH MANUAL BALANCING DAMPERS IN ALL
BRANCH DUCTS TO DIFFUSERS OR GRILLES.
RUNOUT DUCT SIZES SHALL MATCH DIFFUSER
NECK SIZE UNLESS OTHERWISE NOTED.
6. MECHANICAL CONTRACTOR SHALL WORK
WITH DAIKIN REPRESENTATIVE FOR NEW
LAYOUT AND DESIGN OF REFRIGERANT PIPING.
1. REMOVE EXISTING EXHAUST FAN AND ALL
ASSOCIATED DUCTWORK SEAL WALL
PENETRATION WATER AND VAPOR TIGHT. SEE
2/08.03 FOR RELOCATION OF FAN.
2. REINSTALL EXISTING INSTALL FAN IN
EVIDENCE ROOM. COORDINATE FINAL
LOCATION WITH OWNER. ROUTE DUCTWORK
TO ROOF AND PROVIDE ROOF CAP FOR
TERMINATION.
3. REBALANCE EXISTING OUTSIDE AIR DIFFUSER
TO AIRFLOW SHOWN.
4. CONNECT NEW CASSETTE TO EXISTING VRF
SYSTEM. CONNECT REFRIGERANT PIPING INTO
NEW BS-2.1. ROUTE CONDENSATE TO
EXISTING CONDENSATE LINE AS SHOWN ON
PLAN.
5. REMOVE C-1-110-B AND C-1-108-B AND SWAP
CASSETTE LOCATIONS. RECONNECT
CONDENSATE ONCE RELOCATED. RECONNECT
REFRIGERANT PIPING AS NOTED ON
SCHEDULE.
6. REMOVE EXISTING REFRIGERANT PIPING BACK
TO BRANCH CONTROLLER.
7. RECONNECT REFRIGERANT PIPING FOR
EXISTING CASSETTE TO BS AS SHOWN ON
SCHEDULE.
8. PROVIDE NEW BS BOX. CONNECT TO VRF-
CU-1. SIZE AND ROUTE PER MANUFACTURERS
RECOMMENDATIONS.
9. PROVIDE NEW BS BOX. CONNECT TO VRF-
CU-2. SIZE AND ROUTE PER MANUFACTURERS
RECOMMENDATIONS.
10. PROVIDE NEW THERMOSTAT, MATCH MODEL
NUMBER THAT IS EXISTING ON SITE. CONNECT
TO CASSETTE LISTED ON PLANS.
11. EXISTING THERMOSTAT CONTROLLING TWO
CASSETTES. REPROGRAM TO CONTROL ONLY
ONE. CASSETTE TO BE CONTROLLED AS
SHOWN ON PLANS.
12. EXISTING VRF CASSETTE TO REMAIN.
13. CONNECT NEW 1/2" CW LINE TO NEW
REFRIGERATOR IN TRAINING A106. PROVIDE
BFP WATTS MODEL SD-2.
14. EXISTING VRF WALL UNIT TO REMAIN.
TROUBLESHOOT PROBLEMS WITH
CONDENSATE AND PROVIDE NEW
CONDENSATE LINE OVER TO MOP SINK AS
SHOWN ON DRAWING 2/08.03.
15. EXISTING THERMOSTAT TO BE RELOCATED.
REVIEW 2/08.03 FOR RELCOATION.
# SHEET NOTESKEYNOTES
D1>D2
45 DEGREE
BUTT FLANGESTRAIGHT TAP
ENTRY Θ 45°45 DEGREE CONICAL
CLINCH LOCK
CORNER FILLERPIECE OR USEGASKET (TYP.)
45 DEGREE LEAD IN
DOVETAIL JOINT
LINED DUCT CONNECTION(NO EXPOSED LINER EDGES)
DUCT LINER
FLANGED
NOTE:STRAIGHT TAP WITH BUTTFLANGE FOR BRANCH AND TEECONNECTION IN RECTANGULAR DUCTSUNDER 1" PRESSURE CLASS ONLY.
ENTRY Θ 45°
D1
W
L
Θ
D2
(L = 4" OR W/4; WHICHEVER IS LARGER)
NOTES:
1. DO NOT USE CONNECTIONS WITH SCOOPS.2. FIT ALL CONNECTIONS TO AVOID VISIBLE OPENINGS AND
SECURE THEM SUITABLY FOR THE PRESSURE CLASS.3. ADDITIONAL MECHANICAL FASTENERS ARE REQUIRED FOR
4"W.G. AND OVER.4. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION.
CEILING
STRUCTURE
ATTACH FLEX DUCT TO THE HARD DUCT. REFER TO NOTE 1.
HARD DUCT
TRIM STRAPS AFTER TIGHTENING
SUSPEND ELBOW WITH TIE
DRAW BANDS SNUG,WITHOUT CRUSHINGFLEXIBLE DUCT
PROVIDE DURABLE ELBOW SUPPORT. REFER TO NOTE 2.
DIFFUSER
1X DUCT DIAMETERMINIMUM STRAIGHTDUCT
NOTES:
1. TO ATTACH FLEX DUCT TO THE HARD DUCT, TAPE THE INNER LINER TO THE HARD DUCT THEN ATTACH WITH TWO NYLON TIE WRAPS; ONE FOR THE INNER LINER AND ONE FOR THE OUTER SHELL. FOLD THE OUTER SHELL INSIDE ITSELF SO IT HAS NEAT EDGES PRIOR TO TIE WRAPPING.
2. DURABLE ELBOW SUPPORT ACCEPTABLE MANUFACTURER AND MODEL: HART AND COOLEY - SMARTFLOW, THERMAFLEX -FLEXFLOW, TITUS - FLEXRIGHT, OR APPROVED EQUAL.
FLEXIBLE DUCT. MAX. LENGTH PER SPECIFICATIONS
DUCT LINER (REFER TOSPECIFICATION SECTION 23 31 00 - DUCTWORK)
REFER TO DRAWINGFOR SIZE
FLOOR OR ROOF
CEILING
WALL
6".
RG-1
SHEE
T N
O.
CLAY
COM
B AS
SOCI
ATES
, ARC
HITE
CTS
* 660
0 LB
J FR
EEW
AY *
SUIT
E 20
0DA
LLAS
, TEX
AS 7
5240
* W
WW
.CLA
YCO
MB.
NET
08/1
5/20
20
08.04
Man
or, T
exas
MAN
OR
IND
EPEN
DAN
TSC
HO
OL
DIS
TRIC
T
MAN
OR
ISD
JOB
NO
. 220
125
DAT
E: 0
8.15
.202
0
POLI
CE
STAT
ION
ISSU
E: B
ID S
ET
REFERENCE SCALE IN INCHES
0 1 2 3
PROJECT #
IMEG CORP RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS, TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR DATA ARE THE EXCLUSIVE PROPERTY OF IMEG CORP AND SHALL NOT BE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN APPROVAL AND PARTICIPATION OF IMEG CORP. © 2020 IMEG CORP.
14755 PRESTON ROAD, SUITE 845DALLAS, TX 75254972.239.6100 FAX: 972.239.6102www.imegcorp.com
TBPE# F-18632
20002811.00
NOTES: 1.CONTRACTOR SHALL DETERMINE PROPER MARGIN STYLE TO MATCH CEILING CONSTRUCTION. 2.ALL RUN OUT DUCTWORK TO DIFFUSERS SHALL BE NECK SIZE UNLESS OTHERWISE NOTED.
3. ALL RG-1 WILL BE USED IN TRANSFER APPLICATIONS
GRILLES REGISTERS & DIFFUSERS SCHEDULE
TAGNAME MATERIAL CONFIGURATION
MARGIN(NOTE 1)
INLET SIZE (IN.)(NOTE 2) FACE SIZE (IN.)
VOLUMEDAMPER
REQUIRED FINISH MANUFACTURER MODEL NOTES
CD-1 STEEL PANEL FACE LAY-IN 6" 24x24 NO WHITE TITUS OMNI FLUSH FACE PANEL
RG-1 STEEL PERFORATED FACE LAY-IN 12 X 12 24x24 NO WHITE TITUS PAR DUCTED RETURN
NO SCALE
BRANCH CONNECTIONS1 NO SCALE
DIFFUSER CONNECTION DETAIL2
5. REMOVE EXISING REFRIGERANT PIPING BACK TO BS UNIT IS CURRENTLY CONNECTED TO. RECONNECT TO BS SHOWN ON SCHEDULE ON ITS OWN PORT. REPROGRAM EXISITING THERMOSTAT TO CONTROL THIS UNIT ONLY
4. REMOVE EXISING REFRIGERANT PIPING BACK TO BS UNIT IS CURRENTLY CONNECTED TO. RECONNECT TO BS SHOWN ON SCHEDULE ON ITS OWN PORT. PROVIDE NEW THERMOSTAT FOR UNIT, MATCH EXISTING THERMOSTATS ON SITE.
3. NEW UNIT SHALL BE PROVIDED WITH CONDENSATE PUMP AND NEW THERMOSTAT. MATCH EXISTING THERMOSTATS ON SITE.
2. NEW UNIT, TIE INTO EXISTING SYSTEM
1. EXISTING UNIT TO REMAIN WITH NO WORK BEING DONE
NOTES:
C-2-A105 A105 VRF-CU-2 BS-2.1 .5 300 208-1 MFR? NF .3 15 DAIKIN FXZQ05TAVJU CASSETTE 2,3
C-2-A104 EXISTING TO REMAIN VRF-CU-2 BS-4 - - - - - - - DAIKIN FXFQ24TVJU CASSETTE 1
C-2-100C-B A103 VRF-CU-2 BS-4 - - - - - - - DAIKIN FXZQ12MVJU9 CASSETTE 4
C-2-100C-A A104 VRF-CU-2 BS-4 - - - - - - - DAIKIN FXZQ12MVJU9 CASSETTE 5
C-2-A112 EXISTING TO REMAIN VRF-CU-2 BS-4 - - - - - - - DAIKIN FXAQ12PVJU WALL MOUNT 1
C-2-104-B A112 VRF-CU-2 BS-2.1 - - - - - - - DAIKIN FXFQ24TVJU CASSETTE 4
C-2-104-A A106 VRF-CU-2 BS-2.1 - - - - - - - DAIKIN FXFQ24TVJU CASSETTE 5
C-2-A103-B EXISTING TO REMAIN VRF-CU-2 BS-3 - - - - - - - DAIKIN FXFQ24TVJU CASSETTE 1
C-2-A103-A EXISTING TO REMAIN VRF-CU-2 BS-3 - - - - - - - DAIKIN FXFQ24TVJU CASSETTE 1
C-2-101 EXISTING TO REMAIN VRF-CU-2 BS-3 - - - - - - - DAIKIN FXZQ07MVJU9 CASSETTE 1
C-2-102 EXISTING TO REMAIN VRF-CU-2 BS-3 - - - - - - - DAIKIN FXZQ07MVJU9 CASSETTE 1
C-1-A111-B A126 VRF-CU-1 BS-2 - - - - - - - DAIKIN FXZQ18MVJU9 CASSETTE 5
C-1-A111-A A127 VRF-CU-1 BS-2 - - - - - - - DAIKIN FXZQ18MVJU9 CASSETTE 4
C-1-A11A EXISTING TO REMAIN VRF-CU-1 BS-2 - - - - - - - DAIKIN FXZQ18MVJU9 CASSETTE 1
C-1-A107-B EXISTING TO REMAIN VRF-CU-1 BS-2 - - - - - - - DAIKIN FXZQ09MVJU9 CASSETTE 1
C-1-A107-A EXISTING TO REMAIN VRF-CU-1 BS-2 - - - - - - - DAIKIN FXZQ09MVJU9 CASSETTE 1
C-1-A108-B A133 VRF-CU-1 BS-1.2 - - - - - - - DAIKIN FXZQ18MVJU9 CASSETTE 4
C-1-A108-A A117 VRF-CU-1 BS-1 - - - - - - - DAIKIN FXZQ18MVJU9 CASSETTE 5
C-1-A109-B EXISTING TO REMAIN VRF-CU-1 BS-1 - - - - - - - DAIKIN FXZQ18MVJU9 CASSETTE 1
C-1-A109-A EXISTING TO REMAIN VRF-CU-1 BS-1 - - - - - - - DAIKIN FXZQ18MVJU9 CASSETTE 1
C-1-A110-B A128 VRF-CU-1 BS-1.1 - - - - - - - DAIKIN FXZQ09MVJU9 CASSETTE 5
C-1-A110-A A130 VRF-CU-1 BS-1 - - - - - - - DAIKIN FXZQ09MVJU9 CASSETTE 4
C-1-A100D EXISTING TO REMAIN VRF-CU-1 BS-1 - - - - - - - DAIKIN FXZQ09MVJU9 CASSETTE 1
BY (NOTE A) BY (NOTE A)
VOLT-PHASE
DISCONNECT CONTROLLER/STARTERMCA MOCP
SYMBOL AREA SERVEDASSOCIATED VRF
HPASSOCIATED VRF
BSNOMINALTONNAGE
CFM
ELECTRICAL
MANUFACTURER MODEL UNIT STYLE REMARKS
INDOOR UNIT SCHEDULE - VRF
4. ALL ASSOCIATED REFRIGERANT PIPING. CAN REUSE EXISITING AS LONG AS SIZE IS CORRECT.
3. TOTAL OF 6 NEW THEROMSTATS
2. PROVIDE WITH, KHFP26A100C, CLOSED PIPE KIT. INSTALL ON OPEN PORT.
1. PROVIDE WITH CONDENSATE PUMP.
NOTES:
N/A THERMOSTAT DAIKIN MATCH EXISITING ON SITE 3
BS-2.1 QUAD PORT BRANCH SELECTOR DAIKIN BS4Q54TVJ 2,4
BS-1.2 SINGLE PORT BRANCH SELECTOR DAIKIN BSQ36TVJ 4
BS-1.1 SINGLE PORT BRANCH SELECTOR DAIKIN BSQ36TVJ 4
C-2-A105 CEILING CASSETTE DAIKIN FXZQ05TAVJU 1,4
TAG TYPE MFR MODEL NOTES
NEW EQUIPMENT SCHEDULE
BS-2.1 BS4Q54TVJ VRF-CU-2 208-230V 1ph 0.4 15.0 54,000 14.6 x 11.7 x 18.9 48.5 NEW
BS-4 BS4Q54TVJ VRF-CU-2 208-230V 1ph 0.4 15.0 54,000 14.6 x 11.7 x 18.9 48.5 EXISTING
BS-3 BS4Q54TVJ VRF-CU-2 208-230V 1ph 0.4 15.0 54,000 14.6 x 11.7 x 18.9 48.5 EXISTING
BS-1.2 BSQ36TVJ VRF-CU-1 208-230V 1ph 0.1 15.0 36,000 15.3 x 8.1 x 12.8 27.0 NEW
BS-1.1 BSQ36TVJ VRF-CU-1 208-230V 1ph 0.1 15.0 36,000 15.3 x 8.1 x 12.8 27.0 NEW
BS-2 BS4Q54TVJ VRF-CU-1 208-230V 1ph 0.4 15.0 54,000 14.6 x 11.7 x 18.9 48.5 EXISTING
BS-1 BS4Q54TVJ VRF-CU-1 208-230V 1ph 0.4 15.0 54,000 14.6 x 11.7 x 18.9 48.5 EXISTING
TAG MODEL CU SERVED VOLTAGE-PHASE MCA MOCPMAX CAPACITY
PER PORTDIMENSIONS WEIGHT NOTES
BRANCH SELECTOR SCHEDULE
NO SCALE
TRANSFER DUCT DETAIL3
DRAWING TITLE##" = 1'-0"
SPD
DRAWING/ DETAIL TITLENOTE:DRAWING TITLE MAYNOT APPEAR ONLARGE SCALE DETAILDRAWINGS
DETAIL NUMBER
SECTION CUT SYMBOL
NORTH ARROW ENLARGED PLAN DETAIL
REFER TO THISSHEET FORENLARGEDPLAN
ELECTRICAL LEGEND
GENERAL NOTES
1. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATIONS OF LIGHT FIXTURES. CONTRACTORS SHALL COORDINATE LOCATIONS OF LIGHTS, SPEAKERS, AIR DIFFUSERS, GRILLES, AND THE LIKE, WITH REFLECTED CEILING PLAN.
2. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN AND/OR ROOM FINISH SCHEDULE AND VERIFY LIGHT FIXTURE TYPE FOR THE CEILING CONSTRUCTION PRIOR TO ORDERING THE FIXTURES. PROVIDE FIXTURES THAT ARE COMPATIBLE WITH THE CEILING SYSTEM.
3. ALL DEVICES, EQUIPMENT, FIXTURES, AND THE LIKE MUST BE GROUNDED BY USE OF A PROPERLY SIZED GROUNDING CONDUCTOR. MECHANICAL AND ELECTRICAL BONDS OF THE METALLIC RACEWAY SYSTEM SHALL BE MAINTAINED.
4. REFER TO MECHANICAL PLANS FOR EXACT LOCATION OF MECHANICAL EQUIPMENT AND LOCATION DISCONNECT SWITCHES IN ACCORDANCE WITH N.E.C.
5. REFER TO MECHANICAL SPECIFICATIONS, HVAC PLANS AND PLUMBING PLANS FOR ADDITIONAL ELECTRICAL WORK AND REQUIREMENTS.
6. REFER TO "CONTROL SCHEMATICS" MECHANICAL DRAWINGS FOR ADDITIONAL CONTROL WIRING AND CONTROL CONNECTIONS.
7. UNLESS OTHERWISE NOTED, ALL DEVICE ELEVATIONS REFER TO CENTER OF OUTLET BOX. THE CONTRACTOR SHALL COORDINATE ALL OUTLET LOCATIONS WITH OTHER TRADES.
8. PROVIDE "SEAL-OFFS" WHEN PIPING PASSES THROUGH AREAS OF DIFFERENT AMBIENT TEMPERATURES AND/OR HAZARDOUS AREAS.
9. IF MORE THAN THREE DIFFERENT PHASE CONDUCTORS ARE ROUTED IN THE SAME CONDUIT, DERATING SHALL BE TAKEN INTO ACCOUNT. INCREASING THE CONDUCTOR AMPACITY (BY INCREASING WIRE SIZE) TO COMPENSATE AS FOLLOWS:
NO. OF CONDUCTORS AMPACITY INCREASE
4 THRU 6 125%7 THRU 9 145%10 THRU 20 (MAX.) 200%
THE CONDUIT CAPACITY SHALL ALSO INCREASE TO CONFORM TO NEC, CHAPTER 9.
10. ALL FIRE ALARM DEVICES ARE TO BE MOUNTED AT HEIGHTS AS SPECIFIED BY ADA.
11. PROVIDE AND INSTALL "PHASE-LOSS" RELAYS FOR NEW THREE PHASE MECHANICAL EQUIPMENT TO PREVENT SINGLE PHASING. COORDINATE WITH MECHANICAL EQUIPMENT CONTRACTOR.
12. ALL EXIT LIGHTS AND EMERGENCY LIGHTS SHALL HAVE THEIR NORMAL BRANCH CIRCUIT WIRING TIED INTO THE LOCAL CIRCUIT IN THE AREA FOR WHICH THEY SERVE AHEAD OF ALL SWITCHING.
13. ALL BREAKERS USED TO FEED MECHANICAL EQUIPMENT SHALL BE "HACR" TYPE.
14. NO CORDS OR RECEPTACLES SHALL BE PERMITTED ABOVE CEILING.
15. IF A FIRE PUMP IS REQUIRED FOR THE SPRINKLER SYSTEM, A REVISION TO THE ISSUED PERMIT MUST BE OBTAINED PRIOR TO THE COMMENCEMENT OF THIS WORK.
NOTE: NOT ALL SYMBOLS ARE USED ON THIS PROJECT.
ELECTRICAL ABBREVIATIONSABBREVIATIONS USED ON DRAWINGS IN GENERAL ARE LISTED BELOW.
A AMPS
AC AIR CONDITIONING
AF AMP FRAME
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AHU AIR HANDLING UNIT
A.I.C. AMPS INTERRUPTING CAPACITY
ATS AUTOMATIC TRANSFER SWITCH
AT AMP TRIP
BRKR BREAKER
C CONDUIT
CATV CABLE ANTENNA TELEVISION
CKT CIRCUIT
CLG CEILING MOUNTED
CPT CONTROL POWER TRANSFORMER
CPU CENTRAL PROCESSING UNIT
CUH CABINET UNIT HEATER
Cu COPPER
DIA DIAMETER
DISTR DISTRIBUTION
E EXISTING
EC ELECTRICAL CONTRACTOR
EF EXHAUST FAN
ELEC ELECTRICAL
EMEMERGENCY LIGHTING WITH CONNECTION TOEMERGENCY POWER SOURCE
EMT ELECTRICAL METALLIC TUBING
ETR EXISTING TO REMAIN
EXP EXPLOSION PROOF
EWC ELECTRIC WATER COOLER
F FUSE
FAAP FIRE ALARM ANNUNCIATOR PANEL
FACP FIRE ALARM CONTROL PANEL
FAGAP FIRE ALARM GRAPHIC ANNUNCIATOR PANEL
FCU FAN COIL UNIT
FIXT LIGHT FIXTURE
FLUOR FLUORESCENT
FS FUSIBLE SWITCH
G GROUND
GFCI GROUND FAULT CIRCUIT INTERRUPTING PROTECTION
GRC GALVANIZED RIGID CONDUIT
HID HIGH INTENSITY DISCHARGE
HP HORSE POWER
IDF INTERMEDIATE DISTRIBUTION FRAME
IG ISOLATED GROUND
J JUNCTION BOX
KEC KITCHEN EQUIPMENT CONTRACTOR
KVA KILOVOLT AMPERE
KW KILOWATTS
LC LIGHTING CONTACTOR
MCB MAIN CIRCUIT BREAKER
MCC MOTOR CONTROL CENTER
MDF MAIN DISTRIBUTION FRAME
MECH MECHANICAL
MLO MAIN LUG ONLY
MSB MAIN SWITCHBOARD
MTD MOUNTED
NAC NOTIFICATION APPLIANCE CIRCUIT
NEC NATIONAL ELECTRICAL CODE
NIC NOT IN CONTRACT
NL NIGHT LIGHT
NTS NOT TO SCALE
OC ON CENTER
PH PHASE
P POLE
PB PULL BOX
PC PHOTOELECTRIC CONTROL
PE PNEUMATIC/ELECTRIC
PNL PANEL
PVC POLYVINYL CHLORIDE
QR QUARTZ RESTRIKE
R RELOCATED
SW SWITCH
TCP TEMPERATURE CONTROL PANEL
TV TELEVISION
TVSS TRANSIENT VOLTAGE SURGE SUPPRESSOR
TYP TYPICAL
UH UNIT HEATER
UNO UNLESS NOTED OTHERWISE
UPS UNINTERRUPTIBLE POWER SUPPLY
V VOLTS
VAV VARIABLE AIR VOLUME
VFD VARIABLE FREQUENCY DRIVE
VIF VERIFY IN FIELD
VC VOLUME CONTROL
W WATTS OR WALL MOUNTED
WG WIRE GUARD
WP WEATHER PROOF TYPE DEVICE
XFMR TRANSFORMER
GENERAL SYMBOLS
SYMBOL DESCRIPTION
CONDUIT CONCEALED ABOVE CEILING OR IN WALL WHEREVER POSSIBLE
CONDUIT CONCEALED BELOW SLAB OR GRADE
CONDUIT EXPOSED ON CEILING, WALL OR BAR JOIST FOR EXPOSEDTYPE BUILDING CONSTRUCTION
INDICATES NUMBER OF HOT, NEUTRAL, AND GROUND CONDUCTORSIN CONDUIT. TO BE USED AS A GENERAL GUIDE TO SHOW INTENT OF CIRCUITING AND SWITCHING ARRANGEMENT. NOT SHOWN IN ALL CASES. CONTRACTOR SHALL VERIFY AND INSTALL ADDITIONAL CONDUCTOR WHERE REQUIRED
HOME RUN TO PANELBOARD SHOWING CIRCUIT DESIGNATION,INDICATING PANEL AND CIRCUIT BREAKER NUMBER WITHIN PANEL
POWER SYMBOLS
SYMBOL DESCRIPTION
DUPLEX RECEPTACLE
DUPLEX RECEPTACLE LOCATED ABOVE COUNTER
DOUBLE DUPLEX RECEPTACLE
DOUBLE DUPLEX RECEPTACLE LOCATED ABOVE COUNTER
ELECTRIC WATER COOLER GFCI RECEPTACLE. THE CONTRACTORSHALL VERIFY EXACT LOCATION OF WATER COOLER RECEPTACLEWITH MANUFACTURERS DWGS.
DUPLEX RECEPTACLE WITH ISOLATED GROUND
SPECIAL PURPOSE OUTLET, AS NOTED ON PLANS OR SPECIFICATIONS
DUPLEX RECEPTACLE WITH FLEXIBLE CONNECTION TO EQUIPMENT
FLUSH FLOOR MOUNTED DUPLEX RECEPTACLE
FLOOR BOX WITH DUPLEX RECEPTACLE AND COMMUNICATIONOUTLET
LIGHTING/ RECEPTACLE PANEL
DISTRIBUTION/ POWER PANEL
SURGE PROTECTION DEVICE
TRANSFORMER
JUNCTION BOX
MOTOR; SINGLE PHASE
MOTOR; THREE PHASE
MANUAL MOTOR STARTER SWITCH WITH THERMAL OVERLOADPROTECTION AND PILOT LIGHT
NON-FUSED DISCONNECT SWITCH
FUSED DISCONNECT SWITCH
MAGNETIC MOTOR STARTER
MAGNETIC MOTOR STARTER COMBINED WITH DISCONNECT SWITCH
PUSH PLATE FOR DOOR OPERATOR
CIRCUIT BREAKER
FUSIBLE SWITCH
SWITCH PROVIDED W/ MOTORIZED PROJECTION SCREEN, INSTALLEDAND WIRED BY ELECTRICAL
RED EMERGENCY STOP PUSH BUTTON TIED TO SHUNT TRIP MAIN BREAKER
VARIABLE FREQUENCY DRIVE; FURNISHED BY OTHERS, INSTALLEDBY ELECTRICAL CONTRACTOR
A-1
LIGHTING SYMBOLS
SYMBOL DESCRIPTION
2' x 4' LED LIGHT FIXTURE
2' x 4' LED LIGHT FIXTURE WITH CONNECTION TOEMERGENCY POWER SOURCE
1' x 4' LED LIGHT FIXTURE
1' x 4' LED LIGHT FIXTURE WITH CONNECTION TOEMERGENCY POWER SOURCE
LED DOWNLIGHT FIXTURE
LED DOWNLIGHT FIXTURE WITHCONNECTION TO EMERGENCY POWER SOURCE
WALL MOUNTED LIGHT FIXTURE
4' LED STRIP FIXTURE
EXIT LIGHT FIXTURE. SHADED AREA DENOTES SINGLE OR DOUBLEFACE. DIRECTIONAL ARROWS AS SHOWN ON PLANS
EMERGENCY BATTERY PACK FIXTURE
POLE MOUNTED SITE LIGHT FIXTURE. NUMBER OF HEADS AS PERDRAWINGS. (NOTE THAT ARROWS INDICATE DIRECTION FOR WHICHOPTIMUM PHOTOMETRIC PERFORMANCE IS DESIRED. FIELD ROTATEREFLECTOR ASSEMBLY IF REQUIRED.
GENERAL PURPOSE SINGLE POLE SWITCH
DOUBLE POLE TOGGLE SWITCH
GENERAL PURPOSE 3-WAY SWITCH
GENERAL PURPOSE 4-WAY SWITCH
GENERAL PURPOSE KEY-OPERATED SWITCH
GENERAL PURPOSE 3-WAY KEY-OPERATED SWITCH
GENERAL PURPOSE 4-WAY KEY-OPERATED SWITCH
GENERAL PURPOSE SWITCH WITH PILOT LIGHT
CONTACTOR
TIME CLOCK
CEILING MOUNT PHOTOCELL EQUAL TO HUBBELL #OMNI-DT-500-RP
CEILING MOUNT OCCUPANCY SENSOR EQUAL TO HUBBELL #OMNI-DT
WALL SOURCE BOX SCHEDULE
ENLARGED PLAN NUMBER
GROUND
NEUTRAL HOT
VFD
JJ
EWC
N
1
1
SECTION NUMBER
SHEET WHERE SECTION IS DRAWN
PROJECT NORTH
TRUE NORTH
T
PS
T
TC
C
H10
OS
V VACANCY SENSOR SWITCH EQUAL TO HUBBELL #LHIRS-1
1
ELECTRICAL SYSTEM INDICATION
HEAVY LINE-WEIGHTINDICATESNEW WORK
LIGHT LINEWEIGHT-INDICATESEXISTINGEQUIPMENT ORREFERENCEDINFORMATION
HATCH MARKS -EQUIPMENT ORMATERIALS TO BEDISCONNECTEDAND REMOVED
TEXT LEADER
NOTES BY SYMBOLDRAWING REVISION SYMBOL
DRAWING REVISIONNUMBER
KEYEDNOTE NUMBER
X
INFORMATION TEXT
VAV-XX
EQUIPMENT TAG IDENTIFICATION
REFERENCE E002 FOR EQUIPMENT BRANCH CIRCUIT REQUIREMENTS
SYMBOL DESCRIPTION
WS1 4-GANG WIREMOLD WALLSOURCE BOX. REFER TO DETAIL 3/10.17
WS2
DUPLEX RECEPTACLE WITH USB CONNECTION.U
CEILING MOUNT VACANCY SENSOR EQUAL TO HUBBELL #OMNI-DTVS
PC
4-GANG WIREMOLD WALLSOURCE BOX. REFER TO DETAIL 6/10.17
DV DIMMER SWITCH WITH VACANCY SENSOR EQUAL TO HUBBELL #LHD-IRS-3
LV LOW VOLTAGE ON/OFF SWITCH EQUAL TO HUBBELL #NXSW-OO
2
3
4
K
3K
4K
P
GFI DUPLEX RECEPTACLE LOCATED ABOVE COUNTERGFI
GFI DUPLEX RECEPTACLEGFI
GFI
GFI
GFI
GFI
O OCCUPANCY SENSOR SWITCH EQUAL TO HUBBELL #LHIRS-1
O2 OCCUPANCY SENSOR SWITCH EQUAL TO HUBBELL #LHIRS-2
D LOW VOLTAGE RAISE/LOWER DIMMER SWITCH EQUAL TO HUBBELL #NXSW-ORLO
LED LIGHT EMMITING DIODE
D4 LOW VOLTAGE RAISE/LOWER DIMMER SWITCH EQUAL TO HUBBELL #NXSW-SS
SHEE
T N
O.
CLAY
COM
B AS
SOCI
ATES
, ARC
HITE
CTS
* 660
0 LB
J FR
EEW
AY *
SUIT
E 20
0DA
LLAS
, TEX
AS 7
5240
* W
WW
.CLA
YCO
MB.
NET
08/1
5/20
20
10.02
Man
or, T
exas
MAN
OR
IND
EPEN
DAN
TSC
HO
OL
DIS
TRIC
T
MAN
OR
ISD
JOB
NO
. 220
125
DAT
E: 0
8.15
.202
0
POLI
CE
STAT
ION
ISSU
E: B
ID S
ET
REFERENCE SCALE IN INCHES
0 1 2 3
PROJECT #
IMEG CORP RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS, TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR DATA ARE THE EXCLUSIVE PROPERTY OF IMEG CORP AND SHALL NOT BE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN APPROVAL AND PARTICIPATION OF IMEG CORP. © 2020 IMEG CORP.
14755 PRESTON ROAD, SUITE 845DALLAS, TX 75254972.239.6100 FAX: 972.239.6102www.imegcorp.com
TBPE# F-18632
20002811.00
J J J J
J J
OS OS
OS
OS OS
OS
OS
OS
OS
OS
OS
1
2
2
5
4
2
3
5
CEILING
6
1
3
3
3
3
3
11
111
1
A A
DD
P P
8
8
9
9
EE
KK
10
10
HH
7
7
5
5
2
2
CC
FF
B B
JJ
LL
N NMM
GG
4
4
6
6
O O
E E E
E E E
E E E
E E E E E
E
E
E
E E
E
E
E
EE
E E
E
E E
E EEEEE
R R E
E E E
E E E
EE
R
E E
E
E
E E
E
EE
EE
E E
E E
EE
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E E
EE
E E E
R
R
E E
E E
E E
E
EE
E
E
E E
E
DV
EE
E
E EE
1
1
1
1
1 1
1
1 1
1 1
1
2
2
D
E
3
4
3
1
1
1
1
1
1
DV
1
E
DV
5
X
X
E
E
E
E
E
E
R
6
D
D
E
a d
ca
a db
b
E E EEa b c d
E E3 3
E3
E3
a b
a
b
a
b
b
b
b b b
2
D
2
D
E
E
E
E
A
E
E
E
EE
EE
R
E
E
EEEE
EXEC.ASST.A117
MENTOR COORD. &GRANT DIR.
A132
CORRIDORA118
MEETINGA119
COFF/BRKA120
ELECTRICALA121
MDFA124 CUST.
A123
STORAGEA125
TRAININGA126HEALTH SCIENCE
A127
P & W COORDINATORA128
ASST. DIR. HEALTHSERVICES
A130 CORRIDORA122
WOMENA115
MENA114
ADMIN. ASSIST.A102
VESTIBULEA101
CHIEF'SOFFICEA108
SOFT INTERVIEW107 SEC. DOCS.
A110
OFFICESA113
EVIDENCEA109
SHOPA112
TRAININGA106
STORAGEA134PROCESSING/INTERVIEW
A105BREAK ROOMA100C
BECKY'S OFFICEA133
STORAGEA116
E
E
EE E
E
5
1
7
8
5
E
2
SHEE
T N
O.
CLAY
COM
B AS
SOCI
ATES
, ARC
HITE
CTS
* 660
0 LB
J FR
EEW
AY *
SUIT
E 20
0DA
LLAS
, TEX
AS 7
5240
* W
WW
.CLA
YCO
MB.
NET
08/1
5/20
20
10.03
Man
or, T
exas
MAN
OR
IND
EPEN
DAN
TSC
HO
OL
DIS
TRIC
T
MAN
OR
ISD
JOB
NO
. 220
125
DAT
E: 0
8.15
.202
0
POLI
CE
STAT
ION
ISSU
E: B
ID S
ET
REFERENCE SCALE IN INCHES
0 1 2 3
PROJECT #
IMEG CORP RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS, TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR DATA ARE THE EXCLUSIVE PROPERTY OF IMEG CORP AND SHALL NOT BE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN APPROVAL AND PARTICIPATION OF IMEG CORP. © 2020 IMEG CORP.
14755 PRESTON ROAD, SUITE 845DALLAS, TX 75254972.239.6100 FAX: 972.239.6102www.imegcorp.com
TBPE# F-18632
20002811.00
NO R
HT
1/8" = 1'-0"
FIRST FLOOR DEMOLITION - ELECTRICAL2
NO R
HT
1/8" = 1'-0"
FIRST FLOOR PLAN - LIGHTING1
LIGHTING NOTES BY SYMBOL " "#
1. EXISTING CONTROLS THIS AREA TO REMAIN.
2. NEW LOW VOLTAGE DIMMING SWITCH TO BE CONNECTED TO EXISTING LIGHTS/OCCUPANCY SENSOR. RE-WIRE EXISTING OCCUPANCY SENSOR AS NECESSARY TO CONTROL NEW SPACE/EXISTING LIGHTS.
3. EXISTING 3-WAY KEYED SWITCH TO BE RELOCATED TO NEW LOCATION AS SHOWN.
4. EXISTING DOWNLIGHT TO BE CONTROLLED BY CORRIDOR LIGHTING SWITCHES. RE-WIRE AS NECESSARY.
5. RELOCATE EXISTING LIGHT AS INDICATED AND RECONNECT TO EXISTING CIRCUIT/SWITCH OR NEW CONTROLS.
6. NEW OCCUPANCY SENSOR TO MATCH EXISTING. INTERWIRE WITH EXISTING LIGHTING CONTROLS.
7. EXISTING LIGHTS TO BE CONNECTED TO NEW CONTROLS. RE-WIRE AS NECESSARY.
8. NEW LIGHT/CONTROLS TO BE CONNECTED TO EXISTING CIRCUIT THIS AREA WITH (2)#!2,#12G-3/4"C.
DEMOLITION NOTES BY SYMBOL " "#
1. EXISTING LIGHTS TO REMOVED AND MAINTAINED FOR RE-USE.
2. EXISTING SWITCHES TO BE REMOVED. DISCONNECT AND REMOVE ALL ASSOCIATED WIRING. REFER TO NEW WORK NOTE BY SYMBOL #2 FOR MORE INFORMATION.
3. EXISTING RECEPTACLE TO BE REMOVED. DISCONNECT AND REMOVE ALL ASSOCIATED WIRE AND CONDUIT.
4. EXISTING SPECIAL PURPOSE OUTLET AND DISCONNECT SWITCH TO BE REMOVED. DISCONNECT AND REMOVE ALL ASSOCIATED WIRE AND CONDUIT.
5. EXISTING PROJECTOR CONTROLS AND PROJECTOR INTERFACES DEVICES AND ASSOCIATED WIRING TO BE REMOVED/RELOCATED BY OWNER. REMOVE EXISTING JUNCTION BOXES AND ASSOCIATED CONDUIT. REFER TO NOTES BY SYMBOL #7 SHEET 10.04, FOR NEW LOCATION AND ADDITIONAL INFORMATION.
6. EXISTING PROJECTOR CONTROLS, PROJECTOR INTERFACE DEVICES, PROJECTOR AND ASSOCIATED WIRING SHALL BE DISCONNECTED AND REMOVED BY OWNER. REMOVE CEILING MOUNTED RECEPTACLE WIRE, CONDUIT AND JUNCTION BOXES AND CONDUIT FOR PROJECTOR CONTROLS/DEVICES.
1. THE INFORMATION ON THE DEMOLOTION DRAWINGS ARE FROM DOCUMENTS PROVIDED TO THE ENGINEER. CONTRACTOR WILL BE RESPONSIBLE FOR VISITING THE SITE PRIOR TO SUBMITTING A BID TO DETERMINE THE AMOUNT OF DEMOLITION THAT WILL BE REQUIRED. CONTRACTOR SHALL EXAMINE THE EXISTING BUILDING AND GENERALLY VERIFY THE LOCATION OF ALL EXISTING WORK AND BECOME INFORMED AS TO THE RELATION TO AND EFFECT ON, THE WORK REQUIRED BEFORE SUBMITTING A BID. SUBMISSION OF A BID WILL CONSTITUTE EVIDENCE THAT THE CONTRACTOR HAS INSPECTED THE SITE OF THE PROPOSED WORK. DEVICES ON EXISTING WALLS TO REMAIN OR TO BE REMOVED MAY NOT APPEAR ON DRAWINGS DUE TO EXISTING FURNITURE, BOOKCASES, EQUIPMENT, ECT. BLOCKING VIEW DURING SITE VISIT.
2. CONTRACTOR SHALL STUDY ALL PLANS AND UNDERSTAND THE FULL SCOPE OF CONSTRUCTION PRIOR TO BIDS AND BEGINNING ANY WORK. CONTRACTOR SHALL UNDERSTAND THAT THE BUILDING WILL BE RENOVATED IN PHASES AND THAT ELECTRICAL EQUIPMENT SERVING THOSE ARES THAT WILL BE RENOVATED IN LATER PHASES SHALL BE RECONNECTED AND RE-ENERGIZED TO MAINTAIN POWER TO THOSE AREAS IF DISRUPTED DURING PHASED CONSTRUCTION. CONTRACTOR SHALL UNDERSTAND THAT THE ELECTRICAL EQUIPMENT SERVING PORTIONS OF THE BUILDING THAT ARE OUTSIDE OF THIS PROJECT’S SCOPE SHALL REMAIN AND BE RECONNECTED AND RE-ENERGIZED TO MAINTAIN POWER TO HOSE AREAS IF DISRUPTED DURING PHASED CONSTRUCTION.
3. COORDINATE DEMOLITION WORK WITH THE BUILDING MAINTENANCE PERSONNEL AND OTHER TRADES PERFORMING WORK IN THE BUILDING PRIOR TO THE REMOVAL OF ANY ITEMS OF EQUIPMENT OR SYSTEMS THAT WILL AFFECT OTHER SYSTEMS WITHIN THE LIMIT OF NEW CONSTRUCTION OR OTHER AREAS OF THE BUILDING. CONTRACTOR SHALL VERIFY WITH THE OWNER IF THE BUILDING WILL BE OCCUPIED DURING CONSTRUCTION, AND THEREFORE UTILITIES MUST REMAIN IN OPERATION AT ALL TIMES. ANY REQUIRED OUTAGES MUST BE COORDINATED WITH THE OWNER.
4. PRIOR TO THE REMOVAL OF ANY EQUIPMENT, CONTRACTOR MUST VERIFY THE ORIGIN AND TERMINATION OF THOSE SYSTEMS AND CONFIRM THAT THE ITEMS BEING REMOVED DO NOT SERVE ANY ITEMS THAT ARE TO REMAIN DOWN/UP STREAM (INCLUDING THOSE IN AREAS OUTSIDE THE CONTRACTOR LIMITS). IF REMOVAL OF ANY ITEMS DOES DISRUPT OTHER SYSTEMS DOWN/UP STREAM, CONTRACTOR SHALL EXTEND, RECONNECT TO NEW OR RELOCATED EQUIPMENT, AND MAINTAIN FULL FUNCTIONALITY OF SYSTEM.
5. REFER TO HVAC & PLUMBING DRAWINGS FOR OTHER DEMOLITION INFORMATION. DISCONECT AND REMOVE ALL WIRE, CONDUIT, AND DISCONNECT SWITCHES SERVING EQUIPMENT TO BE REMOVED AND LABEL CIRCUIT BREAKER ‘SPARE’.
DEMOLITION GENERAL NOTES:
1. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION OF ALL LIGHT FIXTURES.
2. ALL EMERGENCY BATTERY PACKS AND EMERGENCY LIGHTS, I.E. FIXTURES DESIGNATED WITH AN 'X' SUFFIX (SUCH AS 'AX'), AND EXIT SIGNS SHALL BE CIRCUITED TO UNSWITCHED HOT LEG OF ADJACENT LIGHTING CIRCUIT PER N.E.C. ARTICLES 700 AND 701 UNLESS OTHERWISE NOTED.
3. DEVICES WITH AN 'E' SUBSCRIPT ARE EXISTING TO REMAIN.
GENERAL NOTES:
POLE 15'0" SQUARE STEEL POLE AMERICAN LITE POLE SNS-15-40-11
S5 SIMILAR TO TYPE 'S1' EXCEPT SINGLE HEAD AND TYPE 5R DISTRIBUTION80W
4000K-LEDHUBBELL VPS-36L-80-4K7-5R-UNV-A-BLT
S4-S SIMILAR TO TYPE 'S4' EXCEPT WITH SHIELD80W
4000K-LED
HUBBELL VPS-36L-80-4K7-4-UNV-A-BLT
SHIELD - HSS/VP-S/90-LR/BLT
S4 SIMILAR TO TYPE 'S1' EXCEPT SINGLE HEAD AND TYPE 4 DISTRIBUTION80W
4000K-LEDHUBBELL VPS-36L-80-4K7-4-UNV-A-BLT
S3 SIMILAR TO TYPE 'S1' EXCEPT SINGLE HEAD AND TYPE 3 DISTRIBUTION80W
4000K-LEDHUBBELL VPS-36L-80-4K7-3-UNV-A-BLT
S2 SIMILAR TO TYPE 'S1' EXCEPT SINGLE HEAD AND TYPE 2 DISTRIBUTION80W
4000K-LEDHUBBELL VPS-36L-80-4K7-2-UNV-A-BLT
S1DOUBLE HEAD LED PARKING LOT LIGHTS ON 15 SQUARE STEEL POLE, ACRYLIC LENS, (1) TYPE 3
DISTRIBUTION, (1) TYPE 4 DISTRIBUTION, CAST ALUMINUM HOUSING, BLACK FINISH, LED DRIVER
80W
4000K-LED
TYPE 3 - HUBBELL VPS-36L-80-4K7-3-UNV-A-BLT
TYPE 4 - HUBBELL VPS-36L-80-4K7-3-UNV-A-BLT
XWHITE THERMOPLASTIC EXIT SIGN, UNIVERSAL FACE, GREEN LED, WITH EMERGENCY BATTERY
BACKUPLED COMPASS CEG
R EXISTING LIGHT FIXTURE TO BE RELOCATED N/A N/A
E EXISTING LIGHT FIXTURE TO REMAIN N/A N/A
A 4' LED STRIP LIGHT40W
4000K-LEDCOLUMBIA CSL4-4040
TYPE DESCRIPTION LAMPS MANUFACTURER/CATALOG NUMBER NOTES
LIGHTING FIXTURE SCHEDULE
J
J
J
J
J
J
J
J
J J
J
J
J J
J
J
J
1
1
1
1
1
1 1
8
1
1
1
2
1
E
3
3
3
5
HAR
LDPLA
E E E E E E E E E
E
E
EEE E
E E
E
EE
E
E
E
E
E
E E
E E E E
EEEE E E E
E
E E E E E E E
EEEE
EE
E
EE
E
E
E E
E
E E
E
E
E
E
E
E
E
E
E
EE
E
E
E E
6
4TYPICAL E
92
9
14
12
29 10
212
12
12
14
9
9
7
E E
12
E
E
7
10
10
10
10
2
18
EE
11
E
E
EE
13
HEALTH SCIENCEA127
TRAININGA126
STORAGEA125
MDFA124
CUST.A123
CORRIDORA122
COFF/BRKA120
ELECTRICALA121
P & W COORDINATORA128
ASST. DIR. HEALTHSERVICES
A130
CORRIDORA118
MENTOR COORD. &GRANT DIR.
A132
EXEC.ASST.A117
BECKY'S OFFICEA133
ADMIN. ASSIST.A102
VESTIBULEA101
CHIEF'SOFFICEA108
SOFT INTERVIEW107
SEC. DOCS.A110
EVIDENCEA109
OFFICESA113
SHOPA112
STORAGEA134
PROCESSING/INTERVIEWA105
BREAK ROOMA100C
CUBICLE OFFICESA103
TRAININGA106
15
S
16
V V16
V
9
V
16
17
17
17
BS-2.1BS-1.2
BS-1.1
13
13
13
13
9
19
SHEE
T N
O.
CLAY
COM
B AS
SOCI
ATES
, ARC
HITE
CTS
* 660
0 LB
J FR
EEW
AY *
SUIT
E 20
0DA
LLAS
, TEX
AS 7
5240
* W
WW
.CLA
YCO
MB.
NET
08/1
5/20
20
10.04
Man
or, T
exas
MAN
OR
IND
EPEN
DAN
TSC
HO
OL
DIS
TRIC
T
MAN
OR
ISD
JOB
NO
. 220
125
DAT
E: 0
8.15
.202
0
POLI
CE
STAT
ION
ISSU
E: B
ID S
ET
NO R
HT
1/8" = 1'-0"
FIRST FLOOR PLAN - POWER1
REFERENCE SCALE IN INCHES
0 1 2 3
PROJECT #
IMEG CORP RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS, TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR DATA ARE THE EXCLUSIVE PROPERTY OF IMEG CORP AND SHALL NOT BE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN APPROVAL AND PARTICIPATION OF IMEG CORP. © 2020 IMEG CORP.
14755 PRESTON ROAD, SUITE 845DALLAS, TX 75254972.239.6100 FAX: 972.239.6102www.imegcorp.com
TBPE# F-18632
20002811.00
NOTES BY SYMBOL " "#
1. EXISTING ELECTRICAL DEVICES THIS AREA TO REMAIN.
2. RECEPTACLE AND DATA OUTLET MOUNTED AT 60" ABOVE FINISHED FLOOR FOR MONITOR. VERIFY LOCATION WITH ARCHITECT.
3. EXISTING ABOVE COUNTER RECEPTACLE AND DATA OUTLET (AT A103 ONLY) TO BE RELOCATED TO 18" ABOVE FINISHED FLOOR.
4. DATA ROUGH IN LOCATION. FROM ROUGH IN ROUTE 1" EMPTY CONDUIT WITH PULLSTRING TO 6" ABOVE ACCESSIBLE CEILING.
5. EXISTING DISCONNECT SERVING ABOVE CEILING OUTSIDE AIR UNIT TO REMAIN.
6. RECEPTACLE MOUNTED ON CEILING FOR OVERHEAD PROJECTOR. COORDINATE EXACT LOCATION WITH ARCHITECT. CONNECT TO EXISTING RECEPTACLE CIRCUIT IN ADJACENT ROOM PREVIOUSLY SERVING RELOCATED PROJECTOR WITH (2)#12,#12G-3/4"C.
7. JUNCTION BOX MOUNTED AT 48” AND 18” ABOVE FINISHED FLOOR FOR RELOCATED PROJECTOR DEVICES. FROM BOXES PROVIDE CONDUIT, TO MATCH EXISTING, TO 6” ABOVE ACCESSIBLE CEILING. VERIFY LOCATION OF DEVICES WITH OWNER.
8. EXISTING PROJECTOR AND CONTROLS TO REMAIN.
9. CONNECT TO EXISTING RECEPTACLE CIRCUIT THIS AREA WITH 2#12,#12G-3/4”C. VERIFY EXISTING LOAD, NO MORE THAN (7) RECEPTACLES PER CIRCUIT.
10. CONNECT TO SPARE 20A 120V DEDICATED CIRCUIT ABOVE CEILING WITH 2#12,#12G-3/4”C.
11. FURNISH AND INSTALL (1)20A/2P CIRCUIT BREAKER (MATCH EXISTING) IN EXISTING PANEL ‘LDP’ WITH 2#12,#12G-3/4”C FOR CONNECTION TO NEW HVAC EQUIPMENT. FURNISH AND INSTALL NEW 2P/30AS/NF DISCONNECT FOR HVAC EQUIPMENT.
12. JUNCTION BOX MOUNTED AT 48” ABOVE FINISHED FLOOR WITH ¾” EMPTY CONDUIT TO 6” ABOVE ACCESSIBLE CEILING FOR DOOR ACCESS DEVICE. VERIFY LOCATION WITH SYSTEM INSTALLER.
13. SECURITY CAMERA ROUGH IN LOCATION. FROM ROUGH IN ROUTE 1" EMPTY CONDUIT WITH PULLSTRING TO 6" ABOVE ACCESSIBLE CEILING.
14. JUNCTION BOX WITH 3/4" EMPTY CONDUIT TO 6" ABOVE CEILING FOR DOOR RELEASE PUSHBUTTON. VERIFY MOUNTING HEIGHT AND REQUIREMENTS WITH SYSTEM SUPPLIER.
15. EXISTING SILENT KNIGHT 1FP-1000 FIRE ALARM CONTROL PANEL.
16. CEILING MOUNTED FIRE ALARM SMOKE DETECTOR AND VISUAL DEVICES. CONNECT TO EXISTING DATA LOOP OF ASSOCIATED DEVICE. MATCH EXISTING DEVICES, WIRING AND SUPPORT METHOD.
17. JUNCTION BOX FOR CONNECTION TO NEW BRANCH SELECTOR. COORDINATE EXACT LOCATION AND REQUIREMENTS WITH MECHANICAL CONTRACTOR. CIRCUIT TO NEW 20A/2P CIRCUIT BREAKER INSTALLED IN NOTE #11 WITH (2)#12,#12G-3/4"C. FURNISH AND INSTALL 20A/2P TOGGLE SWITCH FOR DISCONNECT.
18. EXISTING PROJECTOR TO BE RELOCATED. RELOCATION RECEPTACLE AS NEEDED. VERIFY LOCATION WITH ARCHITECT.
19. EXISTING EXHAUST FAN PREVIOUSLY LOCATED IN MECHATRONICS CLASSROOM TO BE RELOCATED TO EVIDENCE 109. EXTEND WIRE AND CONDUIT AND RECONNECT. REFER TO MECHANICAL PLANS FOR ADDITIONAL INFORMATION.
GENERAL NOTES:1. 'E' INDICATES EXISTING ELECTRICAL DEVICE TO REMAIN.