main line flow valve jurisdic - transportation · main line unloading rack oil storage tank...

12
Flow Valve Pump Meter Breakout Tank M Main Line Fenced M JurisdicƟon PHMSA Tank Mixing system Surge Tank (Breakout) Relief To vacuum truck

Upload: others

Post on 28-Jul-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Main Line Flow Valve Jurisdic - Transportation · Main Line Unloading Rack Oil Storage Tank Separator Oil Storage Tank Water Storage Tank Fence e LACT Meter Unregulated M Rural Gathering

 Flow   Valve 

Pump   Meter 

 

Breakout Tank 

 

 Main Line     

Fenced 

 Jurisdic on 

  PHMSA     

       

  Tank Mixing system 

 Surge Tank (Breakout) 

 Relief 

To vacuum truck 

Page 2: Main Line Flow Valve Jurisdic - Transportation · Main Line Unloading Rack Oil Storage Tank Separator Oil Storage Tank Water Storage Tank Fence e LACT Meter Unregulated M Rural Gathering

 Flow   Valve 

Pump   Meter 

 

Storage Tank 

 Main Line     

Fenced 

 

Storage Tank 

Loading Area 

 Jurisdic on 

  PHMSA    Not  Jurisdic onal 

       

If meter is used in conjunc on with Leak detec on system;  jurisdic on ends at Valve #3; if not, it reverts upstream to Valve #1 and #2. 

Pig Re

ceiver 

Page 3: Main Line Flow Valve Jurisdic - Transportation · Main Line Unloading Rack Oil Storage Tank Separator Oil Storage Tank Water Storage Tank Fence e LACT Meter Unregulated M Rural Gathering

 Flow   Valve 

Pump   Meter M 

 Main Line     

Fenced 

 

Storage Tank 

Processing 

Plant 

If meter is used in conjunc on with Leak detec on system;  jurisdic on ends at Valve #2; if not, it reverts up‐stream to Valve #1. 

 M  M 

 Jurisdic on 

  PHMSA   Not  

Jurisdic onal 

       

2  Outlet of Facility:  PHMSA jurisdic‐on extends to 

the pressure influ‐encing device which effects the main pipeline pressure. 

Page 4: Main Line Flow Valve Jurisdic - Transportation · Main Line Unloading Rack Oil Storage Tank Separator Oil Storage Tank Water Storage Tank Fence e LACT Meter Unregulated M Rural Gathering

 Flow   Valve 

Pump   Meter M 

 Main Line     

Fenced 

 

Breakout Tank 

Unloading Rack 

M M 

 

Breakout Tank 

Loading Rack M  M 

 Jurisdic on 

  PHMSA   Not  

Jurisdic onal 

       

Page 5: Main Line Flow Valve Jurisdic - Transportation · Main Line Unloading Rack Oil Storage Tank Separator Oil Storage Tank Water Storage Tank Fence e LACT Meter Unregulated M Rural Gathering

 Flow   Valve 

Pump   Meter M 

 Main Line     

Fenced 

 

Breakout Tank 

 M  M 

 

Breakout Tank 

Loading Rack 

 Jurisdic on 

  PHMSA   Not  

Jurisdic onal 

       

Page 6: Main Line Flow Valve Jurisdic - Transportation · Main Line Unloading Rack Oil Storage Tank Separator Oil Storage Tank Water Storage Tank Fence e LACT Meter Unregulated M Rural Gathering

 Flow   Valve 

Pump   Meter M 

 Main Line     

 Jurisdic on 

  PHMSA   Not  

Jurisdic onal 

       

If meter is used in conjunc on with Leak detec on system;  jurisdic on ends at Valve #2; if not, it reverts up‐stream to Valve #1. 

Fence 

 

Storage Tank 

 M  (Un)Loading Rack 

 

Storage Tank 

 

Storage Tank 

 

Storage Tank 

Storage Tank 

Storage Tank 

 M 

 M 2 

Page 7: Main Line Flow Valve Jurisdic - Transportation · Main Line Unloading Rack Oil Storage Tank Separator Oil Storage Tank Water Storage Tank Fence e LACT Meter Unregulated M Rural Gathering

 Flow   Valve 

Pump   Meter M 

 Main Line     

Fence 

 Breakout Tank 

 M  (Un)Loading Rack 

 Storage Tank 

 Storage Tank 

 Breakout Tank 

 Breakout Tank 

 Breakout Tank 

 M 

 M   

 Jurisdic on 

  PHMSA   Not  

Jurisdic onal 

       

Page 8: Main Line Flow Valve Jurisdic - Transportation · Main Line Unloading Rack Oil Storage Tank Separator Oil Storage Tank Water Storage Tank Fence e LACT Meter Unregulated M Rural Gathering

Main Line

Unloading Rack

Oil Storage

Tank

Separator

Oil Storage

Tank

Water Storage

Tank

Fence

Gas

Lin

e

LACT Meter

M Unregulated Rural Gathering

Line

Rural Gathering Lines must come from production (not truck or rail), are 6 5/8” to 8 5/8”

in diameter, operate at more than 20 % SMYS, and are within 1/4 mile of a USA

M

USA

Separator

M

M

Production Lines

Fence

Unloading Rail or

Truck Rack Fence

This line is not regulated when the

pipeline is low stress and serves

truck or rail, and is less than one mile

Oil Storage

M

Flow Valve PHMSA Regulated Gathering

Version Date:

Pump Meter Not PHMSA Regulated

Unregulated Gathering

3/1/2015

Note: Rural Gathering system

piping that reaches a pipe diame-

ter > 8 5/8 becomes a fully regu-

lated transmission pipeline. If

piping down stream of a transmis-

sion pipeline decreases in size to 8

5/8 or less, it remains a transmis-

sion pipeline.

Regulated Rural Gathering Line

Fully Regulated Non-Rural Gather-ing Line (city limits)

Page 9: Main Line Flow Valve Jurisdic - Transportation · Main Line Unloading Rack Oil Storage Tank Separator Oil Storage Tank Water Storage Tank Fence e LACT Meter Unregulated M Rural Gathering

Flow Valve

Pump Meter M

Main Line

Fenced

Breakout Tank

Refinery

M M

Storage Tank

M Loading Rack

Jurisdiction

PHMSA Not

Jurisdictional

Page 10: Main Line Flow Valve Jurisdic - Transportation · Main Line Unloading Rack Oil Storage Tank Separator Oil Storage Tank Water Storage Tank Fence e LACT Meter Unregulated M Rural Gathering

 Flow   Valve 

Pump   Meter M 

 Jurisdic on 

 Main Line     

Tank Dike 

  

Breakout Tank 

 M  M 

MTR facility (33 CFR 154.1020) ‐ This seg‐ment up to the first valve inside of a tank dike is under Coast Guard Jurisdic on for the purposes of CWA Sec on 311(i). 

Marine  

Loading  

Dock 

  PHMSA    PHMSA/USCG 

 Not  

Jurisdic onal   USCG 

Page 11: Main Line Flow Valve Jurisdic - Transportation · Main Line Unloading Rack Oil Storage Tank Separator Oil Storage Tank Water Storage Tank Fence e LACT Meter Unregulated M Rural Gathering

 Flow   Valve 

Pump   Meter M 

 Main Line     

If meter is used in conjunc on with Leak de-tec on system;  jurisdic on ends at Valve #2; if not, it reverts upstream to Valve #1. 

 

Frac ona on Plant   M  M Loading Rack 

 Jurisdic on 

  PHMSA   Not  

Jurisdic onal 

       

Storage  well 

Storage  well 

Storage  well 

 M 

Page 12: Main Line Flow Valve Jurisdic - Transportation · Main Line Unloading Rack Oil Storage Tank Separator Oil Storage Tank Water Storage Tank Fence e LACT Meter Unregulated M Rural Gathering

 Flow   Valve 

Pump   Meter 

 

Storage Tank 

 Main Line     

Fenced 

 

Storage Tank 

Un‐Loading Area 

 Jurisdic on 

  PHMSA    Unregulated 

       

Pig Laun

cher 

Tank 

Tank 

Tank 

Tank 

  

This line is not regulated when the pipeline is low stress and 

serves truck or rail, and is less than one mile long (measured 

outside facility grounds).