mag switch gears, coimbatore, switch gear equipment
TRANSCRIPT
Oil immersed Starters | Control Panels | Air Break Starters | Single Phase Starters
Suitable for A.C. induction motors & Pumpsets used in HouseholdAgriculture, Industry &
Motor Starters
Safe Guard for Motor
MOTOR ON
Motor Starters
TM
Motor Starters
TM
Motor Starters
TM
Oil Immersed Starter
l
l
l
l
l
l
l
Oil immersed Direct On-Line Starters ranging from 3 HP to 10 HP
Oil immersed Direct On-Line Starters (Heavy Type) OBHD series ranging from 10 HP to 20 HP
Oil immersed Hand operated Star Delta Starter ranging from 5 HP to 35 HP
Contacts made of electrolytic copper material with double break system ensure long life and better conductivity of contacts.
No Volt coil, Tripping coils and Contacts are immersed in oil which absorbs sparking of contacts and coil temperature.
No Volt coils are designed to withstand wide voltage fluctuations.
The magnetic type over load release with adjustable oil dash pot time lag device works on the principle of current and not dependent on the temperature, it enables fine adjustment of the setting even to a fraction of an Ampere, thus eliminating the use of single phase preventor.
Oil immersed Starter Direct on-linewith magnetic / Thermal over load relay
Range 3.0 HP - 20.0 HP
Instructions
Before energizing, remove packing materials and tag along with cotton tape from
guides. Fill in the tank with good quality transformers oil up to the level mark
before energizing (2.25 litres for DOL, 3.25 for HDOL, and 4.25 litres for SD). Oil
must be checked periodically and change oil for better life. To start the motor
press and hold the green colour push button for at least 5 to 10 seconds for
proper functioning in the case of D.O.L starter. In the Star Delta Starters, bring the
handle to “Star” position, then press and hold green colour push button until the
motor gets energized and shift the handle to “Delta” position. it is not possible to
put the handle into “Delta” position without going through “Star” position.
Oil immersed Starter Star-Deltawith magnetic over load relay
Range 7.5 HP - 35 HP
Oil immersed StarterSemi Automatic / Automaticwith Thermal overload relay
Range 7.5 HP - 40 HP
Oil immersed Star Delta Starter Semi Automatic / Automatic
The starter is consisting of three contactors. In the semi automatic starter, the time
delay extends over the period when the start button is kept pressed. The
changeover from star to delta takes place at the instant when the start button is
released. In the automatic starter, delay timer is provided. It changes from star to
delta automatically in the preset time.
OIL IMMERSED STARTER SELECTION TABLE
Motor RatingThree Phase 415 V
HP Kw
Motor Full Load Current
(approx)
Amps
Back-up Fuse RatingMaximum - D.O.L
Back-up Fuse RatingMaximum - Star Delta
(Amps) Amps HRC Fuses
D.O.L Star Delta SDFA
Starter Relay Range
SWG(Rewireable) HRC Fuses SWG (Rewireable)
2.2
3.7
5.5
7.5
9.3
11
15
18.5
22
30
5
7.5
11
14
18
20
28
35
40
60
4-9
8 - 12
12 - 16
15 - 23
18 - 28
22 - 34
30 - 45
20A
35A
50A
50A
50A
63A
80A
25
21
19
19
19
19
17
8 - 12
12 - 16
15 - 23
18 - 28
22 - 34
30 - 45
38 - 45
45 - 65
6 - 10
6 - 10
9 - 15
9 - 15
13 - 21
20 - 32
20 - 32
28 - 44
30 - 50
16A
20A
20A
25A
32A
35A
50A
63A
80A
26
25
25
23
22
21
19
19
17
3
5
7.5
10
12.5
15
20
25
30
40
Motor Starters
TM
Air Break Direct On Line Starter & Star Delta Starter
l
l
l
l
l
l
l
l
Air Break Direct Online Starter ranging from 1 HP to 10 HP
(3 Phase) can be convertable to single phase also.
Air Break Semi Automatic and automatic Star Delta ranging from
5 HP to 15 HP
Contact tips made of thick AgCdo material to withstand extreme
field conditions.
No Volt coils are designed to withstand wide voltage fluctuations.
Bimetal Thermal overload relays are calibrated as per IS
standards will trip off accurately during overload and in phase
failure conditions.
A latch is provided to prevent accidental starting.
Air break starters are suitable for variable load condition motors
with external panel operations such as limit switch and other
electronic controls.
Housed in an attractively powder coated steel enclosure.
Air Break single phase Motor Starter have bimetal overload
auto reset type relay which provides complete protection to single
phase motor. Two pole contactor with No volt coil protects from
voltage variation.
AIR BREAK STARTER SELECTION TABLE
Single Phase 220v Motor Rating (DOL)Three Phase 415 V
Motor Rating ( Star Delta)Three Phase 415 V
Backup Fuse RatingMaximum
HP HP HPKW KW KW
StarterRelayRange
StarterRelayRange
StarterRelayRange
HRCSWG
RewireableSwitches
0.5
1
1.5
2
3
0.37
0.75
1.10
1.50
2.20
4 - 6.5
6 - 10
9 - 14
10 - 16
13 - 21
1
2
3
5
7.5
10
.75
1.5
2.2
3.7
5.5
7.5
1.5 - 2.5
2.5 - 4
4 - 6.5
6 - 10
9 - 14
13-21
16A
25A
25A
32A
32A
32A
35A
25
23
23
21
21
21
21
5
7.5
10
12.5
15
3.7
5.5
7.5
9.3
11
4 - 6.5
6 - 10
9 - 14
11 - 18
13 - 21
Air Break StarterStar - Delta Semi Automatic/
Automatic
Range 5 HP - 15 HP
Air Break StarterDirect On - Line
Range 1.0 HP - 10 HP
l
l
l
Contro l Panels are su i tab le for borewel l and openwel l
submersible pumps.
Single Phase panel with overload auto reset relay and contactor
provides complete protection to single phase motor.
Three phase control panel are provided with Auto Start and single
phase preventer ( It Auto Starts the motor in 3 phase and
Auto Stops in 2 phase )
Control Panels
Air Break StarterDirect On - Line Single Phase
Range 0.5 HP - 3.0 HP
Control Panel(Three Phase)
Control Panel(Single Phase)
Range : 3 HP - 10 HPRange : 0.5 HP - 3 HP
Motor Starters
TM
Motor Starters
TM
www.omaxstarters.com
Motor Starters
TM Site No. E-1, Vasantha Nagar Street No-6, Behind E-B Office, Singanallur, Coimbatore - 641 005.Tamilnadu, INDIA
Phone Mobile : 93622 06195 E - mail : [email protected] : www.omaxstarters.com
: 91-422 - 2272419, 3253253
PRAVIN ENGINEERING
l
l
l
l
l
l
l
l
l
l
l
l
l
l
As given in selection table starter relay ranges are for surface motors. The next higher
relay range must be selected in case of submersible motors where the full load current
is higher than the surface motor.
While placing order please specify motor HP, Voltage, Full load current rating and coil
voltage.
In case of high torque motors, special model starters can be supplied on request.
The local electrical codes and regulations must be followed for installation.
Air Break Starter must be mounted vertically upright
Starter must be protected from rain and direct sunlight. It must have good air
circulation and be away from high temperature locations.
Starter location should be easily accessible for regular inspection and be relatively free
from dust, fumes and moisture.
Starters must be selected with suitable relay range as per motor rating shown in the
selection table.
Turn the current adjustment knobs to set full load current of motor mentioned in the
motor name plate.
Check screws for tightness and give proper earthing to avoid shocks. Starters must
never be used without backup fuses. HRC fuses are preferable for protecting the
installation as well as the relay of the starter against short circuits.
For reverse rotation of motors, interchange any two supply lines. Pilot circuit fuses
must be used incase of remote control operation to protect pilot wiring, which is not
adequately protected by the backup fuses.
There should not be any loose connections in incoming and outgoing terminal.
Please refer operator’s manual supplied along with starter for wiring diagram.
0The ambient temperature should not exceed 40 C
AIR BREAK / OIL IMMERSED STARTERS - INSTRUCTIONS
USE OMAX GENUINE SPARES FOR LONG LIFE AND BETTER PERFORMANCE