maestro occupancy sensing switch - w. w. grainger€¦ · ® maestro ® occupancy sensing switches...
TRANSCRIPT
Job Name:
Job Number:
Model Numbers:
PageSPECIFICATION SUBMITTAL
Maestro® Occupancy Sensing Switch Switch with Occupancy and Vacancy Sensor
369488d 1 05.31.12
Maestro® Occupancy Sensing Switch Lutron® Maestro® Occupancy Sensing switches with occupancy and vacancy sensors are lighting
controls with passive infrared sensors that automatically control the lights in an area. These sensors detect the heat from occupants moving within an area to determine when the space is occupied.
The Occupancy Sensing switch combines a Maestro® switch with an occupancy or vacancy sensor.
Family Features• Passive infrared motion detection with exclusive Lutron® XCTTM Technology for fine motion detection• No neutral wire required (ground connection required for functionality)• 180° sensor field-of-view• Upto30ftx30ft(9mx9m)[900ft 2 (81 m2)] major motion coverage and 20 ft x 20 ft (6 m x 6 m)
[400ft 2(36m2)] minor motion coverage 180° field-of-view• Occupancyversioncanbesettoauto-on/auto-offormanual-on/auto-off• VacancyversionavailabletomeetCAtitle24requirements• Adjustabletimeout–1,5,15,or30minutes• High-lowsensitivityadjustment• OccupancySensingswitchlightingloads:incandescent,halogen,MLV,ELV,CFL,LED,magneticfluorescent,and
electronic fluorescent • -OPS5M-XX**,-VPS5M-XX,-OPS6M2-DV-XX,-VPS6M2-DV-XX,workwithasinglestandard3-wayswitchor
upto9companionswitches(MA-AS-XX,MSC-AS-XX,MA-AS-277-XX,orMSC-AS-277-XX).Standard3-wayswitchcannotbecombinedwithcompanionswitch.Totalblueterminalwirelengthmaybeupto150ft(46m).
** XX in model number represents color/finish code
Occupancy Sensing switch:Model Number* Description Sensor Operation Maximum Capacity
MS-OPS2-XX Occupancy/vacancysingle-pole120 V~
Auto-on/auto-offormanual-on/auto-off
250 W–Incandescent,Halogen,ELV200 W –MLV150 W–CFL,LED2 A–FluorescentBallasts
MS-VPS2-XX Vacancysingle-pole 120 V~ Manual-on/auto-off
250 W–Incandescent,Halogen,ELV200 W –MLV150 W–CFL,LED2 A–FluorescentBallasts
MS-OPS5M-XXOccupancy/vacancysingle-pole/multi- location120 V~
Auto-on/auto-offormanual-on/auto-off
600 W–Incandescent,Halogen,ELV450 W–MLV360 W–CFL,LED5 A–FluorescentBallasts3 A–Fan
MS-VPS5M-XXVacancysingle-pole/ multi-location 120 V~
Manual-on/auto-off
600 W–Incandescent,Halogen,ELV450 W–MLV360 W–CFL,LED5 A–FluorescentBallasts3 A–Fan
MS-OPS6M2-DV-XXOccupancy/vacancysingle-pole/multi- location120-277 V~
Auto-on/auto-offormanual-on/auto-off
6 Alighting(120-277 V~)3 Afan(120 V~ only)
MS-VPS6M2-DV-XXVacancysingle-polemulti-location 120-277 V~
Manual-on/auto-off 6 Alighting(120-277 V~)3 Afan(120 V~ only)
* For additional Maestro® Occupancy Sensing switch options, see Lutron P/N 369270 (model number: MS-OPS6M-DV) and P/N 369659 (MS-OPS6M2N-DV).
Job Name:
Job Number:
Model Numbers:
PageSPECIFICATION SUBMITTAL
Maestro® Occupancy Sensing Switch Switch with Occupancy and Vacancy Sensor
369488d 2 05.31.12
Colors and Finishes
Gloss Finishes Satin Finishes
Taupe TP
Turquoise TQ
Plum PL
Merlot MR
Terracotta TC
Sienna SI
Midnight MN
Hot HT
DesertStone DS
Duetoprintinglimitations,colorsandfinishesshowncannotbeguaranteedtoperfectlymatchactualproduct colors.
Eggshell ES
Biscuit BI
Snow SW
Palladium PD
Greenbriar GB
Bluestone BG
Mocha Stone MS
Goldstone GS
Sea Glass SG
Stone ST
Limestone LS
White WH
Gray GR
Brown BR
Ivory IV
Almond AL
Black BL
Light Almond LA
Job Name:
Job Number:
Model Numbers:
PageSPECIFICATION SUBMITTAL
Maestro® Occupancy Sensing Switch Switch with Occupancy and Vacancy Sensor
369488d 3 05.31.12
Control Voltage Load Type Minimum Load
Maximum Load Neutral ConnectionRequired
Not Ganged
End of Gang
Middle of Gang
MS-OPS2MS-VPS2
120V~ Lighting1 0A 2A 2A 2A NO
MS-OPS5MMS-VPS5M
120V~
Lighting1,2 0A 5A 5A 5A NO
Fan2 0A (0HP)
3A (1/10HP)
3A (1/10HP)
3A (1/10HP)
NO
MS-OPS6M2-DVMS-VPS6M2-DV
120-277 V~ Lighting1,2 0A 6A 6A 6A NO
120V~ Fan2 0A (0HP)
3A (1/10HP)
3A (1/10HP)
3A (1/10HP)
NO
Load Type and Capacity
1 OccupancySensingswitchLoadType:designedforusewithpermanentlyinstalledincandescent,halogen,MLV,ELV,CFL,LED,magneticfluorescent,andelectronicfluorescentlightingloads.
2 Whencontrollinglightandfanloadssimultaneously,maximumloadcapacityis3Aat120V~ only.
Additional Information• ForuseonGFI-controlledcircuits,pleaseseeLutronP/N048440.• ForadditionalMaestro®OccupancySensingswitchmodels,pleasesee
LutronP/N369270(modelnumber:MS-OPS6M-DV)andP/N369659(modelnumber:MS-OPS6M2N-DV).• ForusewithMA-ASorforcontrolfrommorethantwolocations,pleaseseeLutronP/N048435.• Formoreinformationonthemodelnumbersinthisdocument,pleaseseewww.lutron.com/occvacsensors.• LutronTechnicalHotline:1.800.523.9466.
Job Name:
Job Number:
Model Numbers:
PageSPECIFICATION SUBMITTAL
Maestro® Occupancy Sensing Switch Switch with Occupancy and Vacancy Sensor
369488d 4 05.31.12
Specifications
Regulatory Approvals
• ULListedtoU.S.andCanadiansafetyrequirements.• NOMCertification(pending).
Power
Operatingvoltage: 120V~50/60Hz 120-277V~50/60Hz (MS-OPS6M2-DVandMS-VPS6M2-DVonly)
Key Design Features
• Alllightingloads.• Crush/tamperresistantlens.
(MS-OPS6M2-DVandMS-VPS6M2-DVonly)• Smartambientlightdetection.Lightsturnononlyif
ambientlightintheroomislow.Automaticallylearnsuser's preferred setting.
• Adaptiveswitchingalgorithmforextendedrelaylife.• XCTTM Technology for fine motion detection.
Environment
• Ambientoperatingtemperature:32°Fto104°F (0°Cto40°C),0%-90%humidity,non-condensing.Indooruseonly.
Warranty
• 5YearLimitedWarranty. ForadditionalWarrantyinformation,pleasevisit http://www.lutron.com/TechnicalDocumentLibrary/
Sensor_Warranty.pdf
Timeout Options
• 1Minute• 5Minutes• 15Minutes• 30Minutes
Sensitivity Options
• Highsensitivity• Lowsensitivity
Auto-On Options (MS-OPS models only)• “Occupancy”–Auto-On/Auto-Off• “Vacancy”*–Manual-On/Auto-Off• “LowLight”–Lightsturnononlyifneeded
(if ambient light is below threshold)* Thereisa15-secondgraceperiodthatbeginswhenthelightsare
automaticallyturnedoff,duringwhichthelightswillautomaticallyturnback on in response to motion. This grace period is provided as a safety and convenience feature in the event the lights turn off while theroomisstilloccupied,sothattheuserdoesnotneedtomanuallyturnthelightsbackon.After15seconds,thegraceperiodexpiresand the lights must be manually turned on.
Manual Off While Occupied Options (MS-OPS models only)
ENABLED (default setting for MS-OPS6M2-DV)
•WhentheOccupancySensingswitchismanually turnedoff,theOccupancySensingswitchwillnot turn the lights back on automatically while the room is occupied.
•Oncetheroomisvacated,theAuto-onfeature returns to normal operation after the timeout period has expired.
•Thismaybethepreferenceinconferenceroomsor classrooms while viewing presentations. This feature requires motion to keep the lights off.
DISABLED (default setting for MS-OPS2 and MS-OPS5M)
•WhentheOccupancySensingswitchismanuallyturnedoff,theAuto-onfeaturewillreturntonormaloperationafter25seconds.
•Thismaybethepreferenceiftheuseralwayswants the lights to turn on upon entering and the lights to turn off when the room is vacant.
Job Name:
Job Number:
Model Numbers:
PageSPECIFICATION SUBMITTAL
Maestro® Occupancy Sensing Switch Switch with Occupancy and Vacancy Sensor
369488d 5 05.31.12
Beam Diagrams
Occupancy Sensing switch Placement and Operation• The ability of the Occupancy Sensing switch to detect motion requires line-of-sight of room occupants.
The Occupancy Sensing switch must have an unobstructed view of the room.• HotobjectsandmovingaircurrentscanaffecttheperformanceoftheOccupancySensingswitch.• The performance of the Occupancy Sensing switch depends on a temperature differential between the
ambient room temperature and that of room occupants. Warmer rooms may reduce the ability of the Occupancy Sensing switch to detect occupants.
Horizontal Beam Diagram
5 ft (1.5 m)
5 ft (1.5 m)
0
10 ft (3 m)
10 ft (3 m)
15 ft (4.5 m)
15 ft (4.5 m)
20 ft (6 m)
20 ft (6 m)
25 ft (7.5 m)
25 ft (7.5 m)
30 ft (9 m)
30 ft (9 m)
Vertical Beam Diagram
5 ft (1.5 m)
0 10 ft (3 m)
15 ft (4.5 m)
20 ft (6 m)
25 ft (7.5 m)
30 ft (9 m)
4 ft (1.2 m)
Compliant to NEMA WD7 test grid shown below
Tested Coverage Area
10 ft (3 m)
15 ft (4.5 m)
20 ft (6 m)
30 ft (9 m)
Major Motion 900 ft2 (81 m2) coverage
Major Motion 400 ft2 (36 m2) coverage
Job Name:
Job Number:
Model Numbers:
PageSPECIFICATION SUBMITTAL
Maestro® Occupancy Sensing Switch Switch with Occupancy and Vacancy Sensor
369488d 6 05.31.12
Mounting
Wallbox
Sensing switch
AdapterMounting Screws
Mounting Screws
Wallplate/Adapterpurchasedseparately.
Operation
Sensor Lens
TapswitchTapon/off
Occupancy Sensing switch
Sensor LED (behind lens) PulsestoacknowledgemotionwhentheloadisON.
Job Name:
Job Number:
Model Numbers:
PageSPECIFICATION SUBMITTAL
Maestro® Occupancy Sensing Switch Switch with Occupancy and Vacancy Sensor
369488d 7 05.31.12
Occupancy Sensing switches can be ganged without derating.
Ganging and Derating
Dimensions
Measurementsshownas:in(mm)
Front View Side View
5/16(8)
1/8(3)
11⁄8(30)
411⁄16
(119)
215⁄16
(75)
Job Name:
Job Number:
Model Numbers:
PageSPECIFICATION SUBMITTAL
Maestro® Occupancy Sensing Switch Switch with Occupancy and Vacancy Sensor
369488d 8 05.31.12
Single Location Installation (120 V~)1,3
-OPS5M,-VPS5M,-OPS6M2-DV,-VPS6M2-DV
Wiring Diagram 2
Occupancy sensing switch
120V~ 50/60Hz
Green
Ground
Hot/Live
Neutral
Load
Blue1
Bare
Black Black
Wiring Diagrams:
Single Location Installation (120 V~)-OPS2and-VPS2
Wiring Diagram 1
Occupancy sensing switch
120V~ 50/60Hz
Green
Ground
Hot/Live
Neutral
LoadBare
Black Black
3-way Installation with Standard Mechanical Switch (120 V~)2, 4
-OPS5M,-VPS5M,-OPS6M2-DV,-VPS6M2-DV
Black
Blue
Green
Ground
Occupancy sensing switch
Green
Ground
120V~ 50/60Hz
Hot/Live
Neutral
Load
Standard mechanical switch
Black
Jumper wire Bare
Differentcolor
screw (Common)
Black
Blue
Green
Ground
Occupancy sensing switch
Green
Ground120V~ 50/60Hz
Hot/Live
Neutral
Load
Standard mechanical switch
Black
Jumper wireBare
Differentcolor screw (Common)
OR
Wiring Diagram 3
1 Whenusingcontrolsinsinglelocationinstallations,tightentheblueterminalorcapbluewire.Do notconnecttheblueterminal/wiretoanyotherwireortoground.2 Only one Occupancy Sensing switch can be used per multi-location circuit.3 Fanloadappliesto120V~only(Notfor277V~).4 Asinglestandard3-wayswitchorupto9companionswitchesmaybeconnectedtoanOccupancySensingswitch.Standard3-wayswitchcannotbe combinedwithcompanionswitch.Totalblueterminalwirelengthmaybeupto150 ft(46 m)
Job Name:
Job Number:
Model Numbers:
PageSPECIFICATION SUBMITTAL
Maestro® Occupancy Sensing Switch Switch with Occupancy and Vacancy Sensor
369488d 9 05.31.12
3-way Installation with Standard Mechanical Switch (277 V~)1,2,3
-OPS6M2-DV,-VPS6M2-DV
Black
Blue
Green
Ground
Occupancy sensing switch
Green
Ground
277V~ 50/60Hz
Hot/Live
Neutral
Load
Standard mechanical switch
Black
Jumper wireBare
Differentcolor
screw (Common)
Black
Blue
Green
Ground
Occupancy sensing switch
Green
Ground277V~ 50/60Hz
Hot/Live
Load
Standard mechanical switch
Black
Jumper wireBare
Differentcolor screw (Common)
OR
Wiring Diagram 4
Wiring Diagrams: (continued)
Wiring Diagram 5Multi-Location Installation (120 V~)1,2,3,4
-OPS5M,-VPS5M,-OPS6M2-DV,-VPS6M2-DVwithMA-ASorMSC-AS
Blue
Green
Ground
Occupancy sensing switch4
Black
Ground120V~ 50/60Hz
Brass BrassBlack
Blue Blue
Green Green
Ground
Hot/Live
Neutral
Load
MA-AS or MSC-AS
MA-AS or MSC-AS
Bare
Black Black
Neutral
1 Asinglestandard3-wayswitchorupto9companionswitchesmaybeconnectedtoanOccupancySensingswitch.Standard3-wayswitchcannotbe combinedwithcompanionswitch.Totalblueterminalwirelengthmaybeupto150 ft(46 m)2 Only one Occupancy Sensing switch can be used per multi-location circuit.3 Fanloadappliesto120V~only(Notfor277V~.).4 Note:Canbeinstalledinanylocation.
4
Job Name:
Job Number:
Model Numbers:
PageSPECIFICATION SUBMITTAL
Maestro® Occupancy Sensing Switch Switch with Occupancy and Vacancy Sensor
369488d 10 05.31.12
1 Asinglestandard3-wayswitchorupto9companionswitchesmaybeconnectedtoanOccupancySensingswitch.Standard3-wayswitchcannotbe combinedwithcompanionswitch.Totalblueterminalwirelengthmaybeupto150 ft(46 m)2 Only one Occupancy Sensing switch can be used per multi-location circuit.3 Fanloadappliesto120V~only(Notfor277V~).4 Note:Canbeinstalledinanylocation.
Wiring Diagram 6Multi-Location Installation (277 V~)1, 2,3, 4
-OPS6M2-DV,-VPS6M2-DVwithMA-AS-277orMSC-AS-277
Occupancy sensing switch4
Black
Blue
Green
Ground
Black
Blue
Green
Ground
277V~ 50/60Hz
Black
Blue
Green
Ground
Hot/Live
Neutral
Load
RedRed
Bare
Black
MA-AS-277 or MSC-AS-277
MA-AS-277 or MSC-AS-277
4