MACOM II ® Active Magnetic Field Compensation System
Ensures excellent imaging for research, development, quality assurance and medical engineering – with no magnetic interference
By compensating magnetic interference, MACOM II ® enables precise imaging for research, development, quality control and medical diagnostics.
Electron microscopes, highresolution
medical diagnostic equipment and elec
tron beam lithography systems for scan
ning the smallest of structures (such
as in semiconductor manufacturing
for example) require optimum environ
mental conditions to achieve the best
possible results. Research, development,
quality control and diagnostics are the
main applications for highlysensitive
technologies. In addition to a constant
temperature, minimum vibration and
quiet acoustic conditions, a magneti
cally quiet environment is also crucial
for achieving optimum performance.
Magnetic interference fields of just a
few 10 nT already affect the resolu
tion of sensitive systems, while typical
sources of interference such as trams
and trains, power cables and electrical
installations in buildings often create
magnetic interference fields of several
100 nT. Passive screening of these fields
is usually very expensive. MACOM II ®,
the active magnetic field compensation
system from MüllerBBM, creates the
optimum magnetically quiet environ
mental conditions for your systems with
the minimum of effort.
Optimise your imaging output and ex
ploit the performance of your systems
to the full. By enabling more reliable
and meaningful imaging – without in
terfering magnetic fields – MACOM II ®
ensures that your investment in the
latest analytical and diagnostics techno
logy will pay dividends more quickly.
Creating optimum conditions for your work
5
Our experience – your success
For more than 40 years MüllerBBM has
been a leading engineering company in the
field of technical acoustics and vibration
control, and for the past ten years we have
also been acting as consulting engineers for
electromagnetic compatibility. All three fields
are accredited according to DIN EN ISO/IEC
17025, and the quality management system
of MüllerBBM is also certified according to
ISO 9001. As a result of our wideranging
experience, we are able to provide our
customers with a comprehensive service by
performing a site analysis and/or identifying
sources of interference prior to the installa
tion of a sensitive system. Our goal is to cre
ate complete, fully functioning solutions that
deliver perfect results for your work.
The product we offer for magnetic field re
duction is the state of the art MACOM II ®
magnetic field compensation system. Easy to
operate and maintenancefree, this system
automatically creates the optimum working
conditions for you.
Patented technology
All the knowhow we have gathered over
decades of experience from our develop
ment and consultancy work in the area of
magnetic fields has gone into MACOM II ®.
The result is a patented system successfully
used worldwide which helps scientists, re
searchers and physicians analyze and docu
ment their work better. MACOM II ® actively
helps you obtain better results.
The applications of MACOM technology are as exciting as they are wide-ranging:
Material analyses / metallurgical structural investigations
Nanoparticle research
All scanning electron microscope applications
Semiconductor technology / chip manufacture
Medical diagnostics (especially magnetic resonance tomography)
Userfriendly, maintenancefree operation, perfect results – MACOM II ® is bound to convince you of its benefits.
Maintenance-free operation
MACOM II ® automatically neutralizes
interfering magnetic fields. Once it
has been set up correctly during com
missioning, the system requires no fur
ther maintenance. For operating the
system and monitoring its functions
MACOM II ® has a display on which all
parameters can be viewed and adjusted
if necessary. During operation the dis
play shows either the remaining magne
tic field in all three coordinate directions
or the coil current required to create the
opposing field. For optimum support
MACOM II ® is equipped with one serial
and one Ethernet port, allowing it to be
controlled from an external computer
over an intranet or the internet.
The system also supports optional
re mote control or monitoring by
MüllerBBM. The advantage is obvious:
perfect service anywhere in the world
– without incurring unnecessary travel
expenses.
Convincing results
Image from a scanning electron microscope before and after installing MACOM II ®. Influence of a 50 Hz interference source on imaging. Image section 20 nm.
MACOM II ® and MACOM II ® MR – The advantages at a glance
Automatic compensation of magnetic interference fields
Optimised imaging
Enhances the performance of your systems
Patented technology
Easy to operate
Remote control
No maintenance
As vector fields, magnetic fields can be
cancelled out by another field of the
same magnitude in the other direction.
MACOM II ® automates this process. In
practice the superpositioning does not
provide full cancellation, but it does
considerably reduce magnetic inter
ference fields. The prevailing magnetic
field is measured and a corresponding
opposing field is created by means of an
arrangement of currentcarrying coils.
Since magnetic fields change quickly
or slowly depending on the particu
lar source of the interference (e.g. DC
electric trains, electrical switches or mo
ving metallic objects such as lifts, steel
doors or motor vehicles in the vicinity),
MACOM II ® operates across a wide fre
quency range.
The heart of the system is the patented
sensor which measures interference
fields from 0 Hz (constant field) to over
100 kHz. The sensor signal is processed
in an analogue automatic control unit
with a stable control range between
0 Hz and 50 kHz. A broadband power
amplifier generates the current for the
opposing field. The system works as a
closed control loop, with the oppo
sing field instantaneously following the
changes in the interference field.
The coils for the opposing field are
placed at the edges of the space to be
compensated; depending on the size of
this space, a selfsupporting alumi nium
construction may also be used. The sen
sor is mounted at the point where the
maximum field reduction is to be at
tained. If this is not feasible it can also
be placed outside this area, so to some
extent it is possible to utilize the symme
trical properties of the coil arrangement
to freely select the point of maximum
field reduction.
RS 232 | LANSignal Processor
Multiplexer
Probe Room coil
DC-Offset
DA
Filter Pre-amplifi er Final amplifi er
MACOM II ® represents the distillation of our many years of experience in consulting and magnetic field compensation into a cleverly designed and successful patented system.
MACOM II ® – Principle
MüllerBBM – comprehensive solutions from a single sourceOur strengths: consulting, inspecting, measuring, planning
An international engineering consultancy with more than 250 em
ployees, MüllerBBM is represented at nine locations in Germany
and has numerous project offices all over the world. As leaders in
the building, environment and technology fields, our independent
experts, planners and technical specialists have been advising custo
mers since 1962.
As a consulting and development office, MüllerBBM has the know
ledge and experience to create clientfocused solutions, and custo
mer satisfaction is of paramount importance to us. The success of
MACOM II ® worldwide in research, development and medical tech
nology is one of the many fruits of our endeavours.
MACOM II ® and MACOM II ® MR – Technical data
Field reduction *) ............................ 0 – 1 kHz: > 60 dB
1 – 5 kHz: 20 – 60 dB
10 – 50 kHz: 0 – 20 dB
Noise (0 – 50 kHz) ........................... < 1 nT
Long-time stability ........................ < 1 nT
Maximum interference field **) ..... approx. 10 μT
Output current ............................... 3 x 3A
Display ............................................ Flux density or output current,
system parameters
Interfaces ....................................... RS 232, Ethernet
Power input ....................................max. 270 W
Form factor ..................................... 19" 4U rackmount case or desktop
*) The specifications relate to the location of the probe.
**) The strength of the opposing field, and consequently the maximum interference field, depends on the size of the area to be compensated. A room volume of approximately 4m x 4m x 3m is assumed here.
MüllerBBM GmbH
RobertKochStraße 11
D82152 Planegg / Munich
Germany
Phone + 49 (89) 856020
Fax + 49 (89) 85602111
www.MuellerBBM.com
Buildings
Room Acoustics
Electroacoustics and Audio/Visual Systems
Building Acoustics
Thermal and Hygric Building Physics
Building Climatology
Facade Technology
Fire Protection
Building Dynamics
Environment
Air Quality Control
Traffic Noise Control
Industrial Noise Control
Vibration Control
EMEC
Lighting Engineering
Harmful Substances in Buildings
Safety Technology
Technology
Vehicle Acoustics
Ship Acoustics
Railway Technology
Industrial Plant Acoustics
Machinery Acoustics
Psychoacoustics
Mobile Communication
Product Tests
Office Locations
Planegg / Munich Main office
Berlin
Dresden
Frankfurt
Gelsenkirchen
Hamburg
Cologne
Nuremberg
Stuttgart