lrg cfi

150
8 Reliable Fluorescent Solutions From CFI Fluorescent. It's in our name.You can depend on it. Dependability is our promise. Specifiers tell us we deliver on it with every order. How do we do it? Our well-designed luminaires are built with the most modern technology, practically applied, so you don't have to worry. CFI’s proven quality comes from a manufacturing and testing facility second to none, located in Cornwall, Ontario. Recently expanded, it is North America’s most modern fluorescent production facility and the only one in Canada dedicated to fluorescent lighting. We make sure our luminaires provide the latest in energy efficiency, visual com- fort, controlled light distribution and all the features you need to meet your most challenging specifications. Above all, CFI is committed to producing the best fluo- rescent lighting fixtures you can find. The CFI family of fluorescent systems builds upon a solid foundation of quality design, high technology and engineering performance. Innovative luminaires support a thorough understanding of end-user requirements. Continually devel- oping new products (see opposite page), CFI offers innumerable cost-effective, quality lighting solutions suited to a wide range of fluorescent applications. Fluorescent Lighting

Upload: canlyte-canlyte

Post on 29-Mar-2016

322 views

Category:

Documents


11 download

DESCRIPTION

Lighting Resource Guide

TRANSCRIPT

Page 1: LRG CFI

8

Reliable Fluorescent Solutions

From CFI Fluorescent. It's in our name. You can depend on it.Dependability is our promise. Specifiers tell us we deliver on it with every order.How do we do it? Our well-designed luminaires are built with the most moderntechnology, practically applied, so you don't have to worry.

CFI’s proven quality comes from a manufacturing and testing facility second tonone, located in Cornwall, Ontario. Recently expanded, it is North America’s mostmodern fluorescent production facility and the only one in Canada dedicated tofluorescent lighting.

We make sure our luminaires provide the latest in energy efficiency, visual com-fort, controlled light distribution and all the features you need to meet your mostchallenging specifications. Above all, CFI is committed to producing the best fluo-rescent lighting fixtures you can find.

The CFI family of fluorescent systems builds upon a solid foundation of qualitydesign, high technology and engineering performance. Innovative luminairessupport a thorough understanding of end-user requirements. Continually devel-oping new products (see opposite page), CFI offers innumerable cost-effective,quality lighting solutions suited to a wide range of fluorescent applications.

Fluorescent Lighting

Page 2: LRG CFI

9

Introducing more choice, more dependabilityOver 50 new CFI products are featured in the 2006 edition ofthe Canlyte Lighting Resource Guide, including Lytecel, TriLyte,Video Teleconference, Cleanguard and Guardsman.

CFI Fluorescent has always taken a leading role in advancinglighting practices, allowing architects, specifiers and otherlighting professionals to take full advantage of the most up-to-date lighting techniques. Discover all the reasons whyyou can rely on CFI: see pages 8 to 157.

New products

Lytecel pages 40-43

TriLyte pages 102-105

Video Teleconference pages 114-117

Cleanguard pages 108-123

Guardsman pages 124-137

Page 3: LRG CFI

10

The ninth edition of the Illuminating Engineering Society of North America (IESNA) Lighting Handbook opens up a whole new era in lighting design. Itintroduces a wide range of lighting quality factors intended to improve the quality of the visual environment. These factors may include eyesource- taskgeometry, appearance. And lighting solutions based on the Quality of the Visual Environment will be providing many of the answers. Why? For one, welive in a customer driven world. Success is measured more and more in terms of how well people’s needs are met. This shift in values also has animpact. Different lighting is required for different needs, in accordance with important lighting design criteria. The IESNA (illuminating EngineeringSociety of North America) recognizes this.

VDT Story — Outline

Human needs• visibility• task performance• visual performance• social communication• mood and atmosphere• health, safety, well-being• aesthetic udgment

LIGHTINGQUALITY

Economics andthe environment• installation• maintenance• operation• energy• environment

Architecture• form• composition• style• codes and

standards

IESNA Lighting handbook 9th Edition

IESNA Quality of the VisualEnvironment

The IES developed its first recommended practice for VDT lighting in 1989 with theintroduction of IES RP-24. This document outlined the working environment and maderecommendations for lighting an area filled with the VDT vertical tasks combined withthe normal reading and writing horizontal tasks. People working in this environment hadto deal with glare on their screens from windows and the luminance of luminaries visi-ble in their VDT screens. They also had to deal with glare from luminaries visible to themfar off in the distance. The original recommended practice used luminance measured incandelas per meter squared as a benchmark for luminaire selection.

In 2003 the office committee upgraded this standard and created a new benchmarkbase on new data and new VDT technology. The new recommended practice uses max-imum candlepower as part of the luminaire selection criteria. VDT screens havechanged from curved to flat and from monochrome to full color. This led to the changesin the luminaire selection criteria. CFI Fluorescent offers a broad range of VDT solutionsto meet the new criteria. The following table shows a sample list of products suitablefor these applications. There are 2 sets of criteria one for intensive use and one con-sidered the basic design. This criteria can be used as a guide when the VDT quality isunknown.

Maximum Luminous Intensity

Angle From Vertical VDT Intensive VDT Normal

55° 300 cd —65° 220 cd 300 cd75° 135 cd 185 cd85° 45 cd 60 cd

ANSI/IESNA RP-1-04

• Newly developed intensity limits

• To prevent selection fixture with high light intensity at critical viewing angles

• Can cause distraction and glare

• Intensity of light is measured in candelas

• Chart shows new classification for fixtures used withinoffice areas with VDT screens.

• Office areas with older style glass faced screens are the most critcal in regards to glare, Newer LCD Flat Panel displays reduce this concern due to their non-glare surface

• Consideration still needs to be exercised for visual discomfort from the direct view of the luminaire (VCP)

Quality Lighting Criteria Behind the IESNA Lighting Design GuideTo help in evaluating a lighting task, the IESNA has developed a list of 19 quality lighting criteria, the following in abbreviated form is taken fromthe design criteria for Interior Applications. Their relative (weighted) importance to interior lighting applications is illustrated in the Lighting DesignGuide shown opposite.

Appearance of space and luminairesBoth the arrangement of elements and their relationship toone another can provide visual clues that assist occupant ori-entation. It is important that the style of the luminaires, coor-dinate with and enhance the design and architecture of thespace.

Colour appearanceColour appearance can affect visibility and aesthetics.

Daylight integration and controlOutdoor views are deemed physiologically and psychological-ly important (e.g. focusing on distant objects helps relax themuscle of the eyes). Daylight and sunlight can be used to helplight a space, but care should be taken to control the quanti-ty and distribution of the light, and to control heat gain.

Direct glareGlare can cause discomfort and interfere with visibility.Direct glare occurs when light travels directly from thesource to the eye. The IESNA has established glare criteriafor luminaire luminances (see explanation of RP-1 Intensiveand normal luminaire selection for VDT (visual display termi-nal) applications, page 10).

FlickerFlicker is the rapid variation in light sourceintensity, usually most noticeable in peripheral vision. Flickercan make objects or people appear to move at a differentrate from their actual movement.

Light distribution on surfacesPatterns of light resulting from the spacing and light distribu-tion of the luminaires, as well as from objects that can castshadows, can affect task visibility, comfort and perceptions.

Light distribution on task plane (uniformity)Patterns of light on the task plane can be distracting, confus-ing or beneficial. These patterns of light and shadow canaffect task visibility, comfort and perception. Task illumi-nance should be higher than the immediate surround. Worksurface illuminances that are 1.5 to 3 times higher thanthose in the surrounding areas assist in directing the occu-pants’ attention to the task.

Luminances of room surfacesRoom surface luminances influence the perception of bright-ness in a space. Illuminance and reflectance affect lumi-nance. Matte surfaces of high reflectance are effectivematerials for increasing room surface luminances.Luminaires expressly designed for lighting walls or ceilingsare effective tools for increasing room surface luminances.

Page 4: LRG CFI

11

(1, 2)

(1, 2)

B

B

B

D

E

E

Modelling of faces or objectsLighting can reveal the depth, shape and texture of anobject. Through the creation or elimination of shadows,faces and objects can have more or less contrast. Also,because a high percentage of communication is nonverbal,such as in office environments, it is important that the pat-tern of light on faces enables clear recognition and interpre-tation of expressions.

Point(s) of interestA point of interest is the object or place to which attentionis drawn, using a variety of techniques including configura-tion rhythm, luminance contrast and colour contrast.

Reflected glareAlso known as indirect glare, reflected glare occurs whenpolished or glossy surfaces emit uncomfortable bright reflec-tions that reduce task visibility. Veiling reflections are con-trast reducing reflections from semi-specular surfaces thatreduce task visibility. Both phenomena can be mitigated byspecial luminaire optical designs that provide adequate cut-off, especially for VDT applications (see pages 10 and 11).

ShadowsShadows can interfere with task visibility by placing detail indarkness. They can also enhance definition of three-dimen-sional details. Fewer shadows (more uniform brightness) elim-inate points of interest, contributing to a feeling of openness.

Source/Task/Eye geometryThe angular relationships between the viewer, the task andthe luminaire are frequently critical to task visibility. Thisgeometry can both enhance contrast and reduce it.

Sparkle/Desirable reflected highlightsSmall points of high luminance from the luminaire or its com-ponents can enhance visual interest and architecturaldetails.

Surface characteristicsObject characteristics such as texture, colour, and speculari-ty and reflectance values of surfaces, can affect the per-ceived brightness of walls and ceilings. High reflectancesalso allow the designer to produce an effective lighted envi-ronment with fewer watts and fewer luminaires.

System control and flexibilityMany spaces require different light levels for a variety oftasks. Conference rooms, for example, need to have equip-ment that provides for settings for slide shows, personnelinterviews, presentations and cleaning.

Special considerationsOften there are special issues associated with a specificlocation or task. These are usually presented in the form ofnotes relating to the recommended practice.

Illuminance (horizontal)Horizontal illuminance is the density of luminous flux fallingonto a horizontal surface.

Illuminance (vertical)Vertical illuminance is the density of luminous flux fallingonto a vertical surface.

Notes:• (1) Lighting should be flexible to accommodate changes in office furniture. • (2) Acoustical aspects of luminaires need to be considered. • (3) Consider lighting for video cameras.• (4) See special considerations for lighting healthcare facilities in Chapter 16 of the IESNA Lighting Handbook. • (5) The task may be horizontal, inclined or vertical.• (6) The minimum illuminance in a prison cell is 200 lx (20 fc); 300 lx (30 fc) should be provided for reading at the head of the bed.

*Determination of illuminance categoriesOrientation and simple visual tasksA Public spaces 30 lx (3 fc)B Simple orientation for short visits 50 lx (5 fc)C Working spaces where simple visual tasks are performed 100 lx (10 fc)

Common visual tasksD Performance of visual tasks of high contrast and large size 300 lx (30 fc)E Performance of visual tasks of high contrast and small size, or visual tasks of low contrast and large size 500 lx (50 fc)F Performance of visual tasks of low contrast and small size 1,000 lx (100 fc)Special visual tasksG Performance of visual tasks near threshold 3,000 to 10,000 lx

(300 to 1,000 fc)

†CFI Fluorescent has edited the IESNA Design Guidefor purposes of simplicity and brevity. The Guide is basedon examples taken from the IESNA Lighting Handbbook9th Edition Chapter 10. Lighting professionals requiringfurther details should consult the ninth edition of theIESNA Lighting Handbook. A copy of the Handbook canbe obtained by contacting the Publications Departmentof the IESNA at 212- 248- 5000 or www. iesna. org.

Quality Lighting IESNA Lighting Design Guide†

LIG

HTI

NG

DES

IGN

ISSU

ES

INTERIOR APPLICATIONS

Setting a new course for

lighting quality

The Design Guide† (opposite)illustrates the new IESNAlighting recommendationsfor common interiorapplications.

OFFICES

Open-plan office:

Intensive VDT use

Intermittent VDT use

Private office

Very important Important Somewhat Blank = Not important important or not applicable

Appe

aran

ce o

f spa

ce a

nd lu

min

aire

s

Colo

ur a

ppea

ranc

e

Dayl

ight

inte

grat

ion

and

cont

rol

Dire

ct g

lare

Flic

ker

Ligh

t dis

tribu

tion

on s

urfa

ces

Ligh

t dis

tribu

tion

on ta

sk p

lane

(uni

form

ity)

Lum

inan

ces

of ro

om s

urfa

ces

Mod

ellin

g of

face

s or

obe

cts

Poin

t(s) o

f int

eres

t

Refle

cted

gla

re

Shad

ows

Sour

ce /

Task

/ Ey

e ge

omet

ry

Spar

kle

/ Des

irabl

e re

flect

ed h

ighl

ight

s

Surfa

ce c

hara

cter

istic

s

Syst

em c

ontro

l and

flex

ibili

ty

Spec

ial c

onsi

dera

tions

Not

es o

n sp

ecia

l con

side

ratio

ns

Illum

inan

ce (h

orizo

ntal

)

Cate

gory

/ Va

lue

(lux)

*

Illum

inan

ce (v

ertic

al)

Cate

gory

/ Va

lue

(lux)

*

Page 5: LRG CFI

12

With TriLyte, CFI Fluorescent now offers a T5/T8 fluorescent solution forlowbay/ highbay lighting in retail, recreational and industrial applica-tions. TriLyte provides the cost-effective benefits of fluorescent lamps,including quality lighting, superior energy efficiency and occupancysensing capabilities.

See the Benefits that Fluorescent Light Can Give You

Instant Light: TriLyte features no restrike/warmup delays.Instant-on T5/T8 TriLyte is well-adapted to speedy warehouse material placement and

retrieval. Also, TriLyte fluorescent lighting is compatible with energy-saving controls, therebycreating new opportunities for occupancy sensing and full-intensity dimming.

High CRI:TriLyte's punch of white light ideal for making merchandise stand out.

TriLyte T5/T8 fluorescent lighting features high colour rendering indices that yield true, vividcolours ideally suited to retail applications.

Low-Shadow Optic DesignBoth T8 and T5 lamps are effective at room temperature, with T5 lamping more ideally suitedto warmer environments, such as gymnasiums and warehouses without climate control. Thereflector design of this fixture is multi-chambered and individual to the lamp. This results in

efficient, directional light which yeilds uniform and highly luminous light on vertical surfaces inareas such as warehouse racking and inventory storage.

Lumen MaintenanceNew fluorescent lamps have improved lumen depreciation with some losing only 5% over

their life, resulting in fewer fixtures needed for the same maintained light lowering both ini-tial cost and operating cost

Sensor Positioning : On The Luminaire Or In The Lighted Area ?Much depends on your application. As a rule, remotely mounted configurations require fewer occupancy detectors per aisle because of the sensor’s longand narrow field of view. However, wider coverage with luminaire-mounted occupancy detectors may be better suited to certain locations.

Luminaire-Mounted Motion SensorField of view

• Wide coverage, ideal for warehouse aisle applications.

• Detection pattern: 30-50 foot width at mounting heights of up to 45 ft.

• Uses passive infrared (PIR) technology shielded by a fresnel lens; upon detection of infrared energy levels, the sensor is triggered and switches the light on.

Remote-Mounted Motion SensorField of view

• Narrow coverage, ideal for long aisles.

• Detection pattern: When mounted 30 ft. from floor (typical), range is 110 ft. x 15 ft. (width).

• For aisles 100 ft. and over, use one sensor at each aisle extremity.

• Uses passive infrared (PIR) technology

T5 Highbay Story

Page 6: LRG CFI

13

ENERGY SMART

Lens Troffer Story

Lens technologies are an important element in fluorescent lighting, they provide economic solutions for many less sensitive work and utlity areaswithin projects. Through the aide of lens technology application, the recessed troffer can even accommodate for specialized lighting needs at anaffordable cost.

The proper lens can supply:• Radio frequency emissions control • Computer friendly lenses for VDT environments• Ultra violet filtering • Energy efficiency by a combination of symmetric / asymmetric distribution

CFI Fluorescent offers three levels of quality to service every application.

General Specification Troffer AA family• Shallow 3 5/8” depth for low plenum application • Hemmed edges for safe handling• Good value recessed luminaire for general lighting and design build projects • Hinged door frame with mitered corners• Very competitive pricing for high volume markets • Cam action latches• Very efficient – over 74% luminaire efficiency (3-lamp model) • Regressed aluminum door frame option• Built in hold down clips on 2x2 and 2x4 models • Reversible door frame

Mid-Grade Specification Troffer SQS family• 4” depth helps reduce lamp image against lens • Cam action latches• Competitive performance with most specification grade troffers • One piece housing• Very efficient – up to 74% luminaire efficiency • Built in hold down clips on 2x2 and 2x4 models• Full size steel lens frame

Premium Specification Grade Troffers SPS family• 5” depth results in further reduction of lamp image against lens • Door jamb finished black on four sides for positive light stop• Up to 83% efficiency • Flush and regressed aluminum door frame options• One piece housing has ribbed construction for added strength • Spring loaded latches• Slimline door frame with 1,000 square inch lens opening

Healthcare and Cleanroom Lighting• MD4 and MD Coffer surface multi-function fixtures• Precise light control for glare free environment• Multi-level control that includes Ambient, Reading, Examination and optional Nurse’s Night Light functions• Possiblities for integral low voltage sequential switch mounted in fixture that allows individual control by the patient throught the use of a pillow switch (others)• Wall mount fixture models BED and OBL offer possibilities independent uplight/downlight switching and nurse’s night light options.• Cleanroom fixture (see pages 118-119 ) availability includes a recessed troffer series with ratings of Class 1,000 to Class 10,000 . Designed for 1.5” and

standard 15/16” tee and meets Federal Standard 209E for cleanroom application.

Industrial and Security Lighting• Fixtures available to suit a majority of needs within Industrial environments• Fixtures suited for applications of concerns of gasses, vapors and liquids, combustible dust or fibers,or simply areas of wet locations, damp locations

or areas of vibration or shock.• For security environments we have options in vandal resistance. A new line of fixtures address for higher security concerns with variations of 14-18

gauge steel housings and optional lenses materials of polycarbonate and tempered glass.

Special Visual Environments• A new fixture designed for video teleconferencing, where vertical distribution and lighting control through dimming solutions are essential.• Specialized wall washing luminaries provide uniform wall washing of vertical surfaces• Wall mounted luminaries designed to light the ceilings in small office spaces

New Canadian Energy Efficient regulations — Fluorescent Lamp BallastsNational Resources Canada has assigned new ballast efficacies to comply with new regulations being set forth in the United States by the Department of energy. The new bal-last efficacies affect ballasts that operate F32T8, F34T12, F40T10, or F40T12 rapid start; or F96T12IS, F96T12ES, F96T12HO, or F96T12HO ES fluorescent lamps. The new regula-tion has set higher limits to ballast efficacies, which as a result, will leave some ballast’s non-compliant. Ballasts affected by this new ruling are primarily T12 magnetic in ori-gin. At present, all magnetic T12 ballast requests are presently being fulfilled by internal inventory supply. All T12 requests will be subject to availability by CFI Fluorescent basedon its inventory at the time. In order to comply with the new regulation, ballast manufacturers have had to cease production of these models for OEM use since April 2005.Further information regarding the OEE — Canada’s Energy Efficient regulations can be found through this NRC - Natural Resources Canada website link : http://oee.nrcan.gc.ca/regulations/fluorescent_august2005.cfm?text=N&printview=N

Special Applications

Page 7: LRG CFI

14

DDA/DQA 20”x 60” - 20”x 48”p. 44-45 MPA 2’x 2’ - 2’x 4’ p. 46-47 PRA 1’x 4’ - 2’x 2’ - 2’x 4’ p. 48-49 SPS 1’x 4’ - 2’x 2’ - 2’x 4’ p. 50-51

SQS 2’x 4’ p. 52-53 MR 1’x 4’ - 1’x 8’ p. 52-53 AA 1’x 4’ - 2’x 2’ - 2’x 4’ p. 54-55 AAS/ELS 1’x 4’ - 2’x 2’ - 2’x 4’ p. 56-57

DSA 20”x 60” p. 58-59 DTA 20”x 48”p. 58-59 WLRN 24”x 48” p. 60-61 WMRL 24”x 48” p. 62-63

VPA/VRA 2’x 2’ p. 20-21 VRA 2’x 2’ p. 22-23 ADS/ADA 8”x 48’p. 24-25

ADS 1’x 4’ p. 24-25 DZA/DXA 1’x 4’ - 1’x 5’ p. 26-27 DVS 20”x 60” p. 26-27 DVA 20”x 60” p. 26-27

VPA 1’x 4’ p. 28-29 VRA/STA 1’x 4’ p. 30-31 DPA 2’x 4’ p. 32-33 DPA 2’x 2’ p. 34-35

PLA 2’x 4’ p. 36-37 PLA 2’x 2’ p. 38-39 LIA9 9”x 48” p. 40-41 LCA9 9”x 48” / LCS8 8”x 48” p. 42-43

VPA/VRA 2’x 4’ p. 18-19

PARABOLIC AND LENS RECESSED LUMINAIRES

Page 8: LRG CFI

15

CCW p. 86 CVW 2’ - 3’ - 4’ p.87

CWBU/LWBU 2’ - 3’ - 4’ p. 88-89 Belmont II 4’ p. 90 Belmont Cloud 4’ p. 91

Lumiplex 1’x 4’ - 2’x 2’ - 2’x 4’ p. 91

DPB 2’x 2’ - 2’x 4’ p. 70-71 ADB 8”x 48” - 1’x 4’ p. 72-73 MLB 2’x 2’ - 2’x 4’ p. 72-73

PNB 1’x 4’. - 2’x 2’ - 2’x 4’ p. 74-75

TH 4’ - 8’ p. 80-81

GMB 4’ - 8’ p. 78-79

TT 4’ p. 82-83 TX 4’ p. 84-85

CSW/CTW 2’ - 3’ - 4’ p. 86-87

Belmont I 4’ p. 90

TN 2’ - 4’ - 8’ p. 82-83

CBS 4’ p. 80-81SLB 1’x 4’ - 2’x 2’ - 2’x 4’ p. 76-77

TSL p. 66-67 TCU p. 66-67

Vandal 1’x 2’ - 1’x 4’ p. 84-85

VRB 1’x 4’ p. 68-69

BLSW 24”x 48” (ceiling) p. 64-65 BLSW 24”x 48” (wall) p. 64-65

PENDANT AND SURFACE

Page 9: LRG CFI

16

T5 SV p. 92-93 T5 SM p. 92-93 T5 SS p. 92-93

SB Strips p. 96-97

T5 SV5R Symmetric p. 94-95

SB9R Narrow Beam Reflectorsp. 100-101

STG Staggered Strip p. 98-99 CSM Side Mount Strip p. 98-99T5 SV5R Asymmetric p. 94-95

SB9R Wide Beam Reflectorsp. 100-101

Trilyte 4’ - 8’ p. 102-103 Trilyte 4’ 6-Lamp p. 104-105

STRIPS AND INDUSTRIALS

EE/FF Industrial p. 106-107 TU Turret Industrial p. 106-107

VT/VTS 4’- 8’ p. 108-109 SW 4’- 8’ 110-111 RVS 1’x 4’ - 2’x 2’ - 2’x 4’ p. 110-111 HSC 4’ p. 112-113

VTS 2’x 4’ p. 114-115 VTS 2’x 2’ p. 116-117 CXSW 2’x 2’ - 2’x 4’ p.118-119 CXS 2’x 2’ - 2’x 4’ p. 120-121

WES 2’x 2’- 2’x 4’ p. 122-123 RV Guardsman Corner Mount4’ p. 124-125

RV Guardsman 1’x 4’ - 2’x 2, - 2’x 4’p. 126-127

RV Guardsman 1’x 4’ - 2’x 2, - 2’x 4’p. 128-129

SPECIAL APPLICATIONS

Page 10: LRG CFI

17

SPECIAL APPLICATIONS

MD2 2’x 2’ / MD4 2’x 4’ p. 138-139Multi-Function Luminaire

MDC 2’x 2’ - 2’x 4’ p. 140-141Multi-Function Luminaire

MDS p. 144-145Recessed for Medical Exams

OBL 4’ p. 146-147 BED 3’- 4’ p. 146-147

MÉDICAL

SUS p.142-143Recessed for Operating Room

GVS 1’x 4’ - 2’x 2’- 2’x 4’p. 130-131

GVB 1’x 4’ - 2’x 2’- 2’x 4’p. 132-133

GV4 4’- 8’ p. 134-135 GSW 2’- 4’ p. 136-137

Page 11: LRG CFI

1437

1000

500

0

30°

60°24" (610 mm)

18 cells

6"(152 mm)

48"(1219 mm)

12 cells

24" (610 mm)

6"(152 mm)

48"(1219 mm)

1510

1000

500

0

30°

60°

24" (610 mm)

27 cells

6"(152 mm)

48"(1219 mm) 2798

2000

1000

0

30°

60°

24" (610 mm)

18 cells

6"(152 mm)

48"(1219 mm) 2532

2000

1000

0

30°

60°

18

VPA 2’x 4’

VRA 2’x 4’

VPA 2’x 4’

VRA 2’x 4’

18 Cells

VRA2G18LP332120O3 (Data)

VPA2G27PP332120O3 (Data)

27 Cells

12 Cells

18 Cells

VPA2G29PR232120SO (Data)

VRA2G12LS232120SO (Data)

Vision Smart 2 x 4 Parabolics meet the Preferred and Basic Criteria ofIES RP-1. The troffers deliver medium to high levels with the bestperformance in terms of efficiency, wide spacing, and excellent glarecontrol. The VP Series complies with the Preferred criteria and is espe-cially suited wherever use of VDTs is prolonged and intensive. The VRSeries complies with the Basic Criteria and is suited wherever use ofVDTs is occasional or nonintensive. The 2-lamp models perform betterthan 3-lamp models. They deliver the RP-1 required 30-50 footcandles,with balanced brightness. They do not wash out the VDT or createexcessive luminance ratios.

Features•VP unit meets RP-1 preferred criteria for lighting VDT areas.•Candelas at Nadir (0°), 1437 on 2-lamp VP.•VP 2 lamp unit provides 50 maintained footcandles at .78 watts/sq. ft.

(8 x 10) module.•Specular low iridescence pre-anodized louver in VP model.•VR unit meets IES RP-1 recommended criteria for lighting

VDT areas.•Candelas at Nadir (0°), 1510 on 2-lamp VR.•Semi-specular low iridescence pre-anodized louver in VR model.•Concealed spring-loaded latch/hinge can be opened either side.•Only 6" deep.•Hold-down clips.•Protective film dust guard.•4” deep aluminum parabolic louver.

Options pages 150-156Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO.Magnetic Electronic PowerSpec DimmingT8: OC T8: SO T8: PS

3 LPB T8: O3 (not avail. in 347V)T12 not available.LPB : Number of lamps per ballast. Drywall Kit For plaster frames, order Cat. No.: FK92X4 (2’ x 4’).Radio Interference Filter 120, 277 or 347 volt, 50 or 60 Hz. Suffix: R.Emergency Lighting System Suffix: O (e.g. VPA2G29PR232120SOO).Emergency battery pack with charger.(90 minutes at 15% of lumens for 1 lamp).Louver Finish Low iridescence specular is standard on VP models. Lowiridescence semi-specular is standard on VR models. Air Pattern Control and Air Slot Closure For horizontal and verticalair supply and to balance return air. Suffix: S.Static For static luminaires, replace A in the basic catalogue numberby S.

RCR C. U.1 782 703 634 565 506 447 398 359 3110 27

RCR C. U.1 772 703 644 575 526 477 428 389 3310 30

RCR C. U.1 722 663 604 555 506 467 428 399 3610 34

RCR C. U.1 702 643 584 525 486 447 408 379 3410 31

Recessed Luminaires ParabolicVision Smart 2’ x 4’ (VPA, VRA)4” Deep Cells • Air Handling/Static Luminaires

PARABOLICS

Page 12: LRG CFI

VPA2G29PR232 120 SO

VRA2G12LS232 120 SO

VPA2G27PP32 120 03

VRA2G18LP332 120 03

19

Ordering Guide

Ordering Guide

Type Cells Lamps Exposed Exposed Slot-T orqty/type T-Grid Concealed T-Grid

Air 18 2-T8 VPA2G29PR232 VPA2T29PR232Handling

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :4" Deep Precision 120 See page 18 See page 18Contoured Preanodized 277 Add appropriateAluminum Parabolic Louver 347 suffix to catalogue

number

Type Cells Lamps Exposed Exposed Slot-T orqty/type T-Grid Concealed T-Grid

Air 12 2-T8 VRA2G12LS232 VRA2T12LS232Handling

Basic catalogue number : Voltage : Ballast : Options :

Type Cells Lamps Exposed Exposed Slot-T orqty/type T-Grid Concealed T-Grid

Air 27 3-T8 VPA2G27PP332 VPA2T27PP332Handling

Basic catalogue number : Voltage : Ballast : Options :

Ordering GuideType Cells Lamps Exposed Exposed Slot-T or

qty/type T-Grid Concealed T-GridAir 18 3-T8 VRA2G18LP332 VRA2T18LP332Handling

Basic catalogue number : Voltage : Ballast : Options :

*Average Footcandles Maintained Total LLF=.82 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens

Recessed LuminairesParabolic

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 62 99 0.9

8' x 10' (80 sq ft/luminaire) 50 99 0.8

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 64 94 1.2

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 40 99 0.9

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 62 97 0.9

8' x 10' (80 sq ft/luminaire) 50 97 0.8

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 63 91 1.2

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 40 97 0.9

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 87 99 1.3

8' x 10' (80 sq ft/luminaire) 71 98 1.1

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 95 95 1.8

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 57 99 1.3

Reference Data

Efficiency 70.0%Spacing Ratio 1.8

LUMINOUS INTENSITY

55° 75cd65° 0cd75° 0cd85° 0cd

Electronic Ballast

Input Watts (120V) 62.0WBallast Factor .88

Reference Data

Efficiency 70.9%Spacing Ratio 1.8

LUMINOUS INTENSITY

55° 537cd65° 45cd75° 10cd85° 2cd

Electronic Ballast

Input Watts (120V) 62.0WBallast Factor .88

Reference Data

Efficiency 66.0%Spacing Ratio 1.5

LUMINOUS INTENSITY

55° 41cd65° 0cd75° 0cd85° 0cd

Electronic Ballast

Input Watts (120V) 85.0WBallast Factor .88

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 85 96 1.3

8' x 10' (80 sq ft/luminaire) 70 96 1.1

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 90 87 1.8

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 55 96 1.3

Reference Data

Efficiency 64.5%Spacing Ratio 1.4

LUMINOUS INTENSITY

55° 971cd65° 81cd75° 24cd85° 0cd

Electronic Ballast

Input Watts (120V) 85.0WBallast Factor .88

Page 13: LRG CFI

1598

1000

500

0

30°

60°

24" (610 mm)

16 cells

6"(152 mm)

24"(610 mm)

24" (610 mm)

16 cells

6"(152 mm)

24"(610 mm)

1224

1000

500

0

30°

60°

24" (610 mm)

12 cells

6"(152 mm)

24"(610 mm)

1225

1000

500

0

30°

60°

24" (610 mm)

9 cells

6"(152 mm)

24"(610 mm) 1219

1000

500

0

30°

60°

20

VRA 2’x 2’

VPA 2’x 2’

VRA 2’x 2’

VPA 2’x 2’

PARABOLICS

Vision Smart VP/VR architecturally symmetrical 2 x 2 Parabolics meet thePreferred and Basic Criteria of IES RP-1. The troffers deliver medium tohigh levels with the best performance in terms of efficiency, wide spac-ing, and excellent glare control. The VP Series complies with thePreferred criteria and is especially suited wherever use of VDTs is pro-longed and intensive. The VR Series complies with the Basic Criteria andis suited wherever use of VDTs is occasional or nonintensive.

Features•VP unit meets IES RP-1 preferred criteria for lighting VDT areas.•Candelas at Nadir (0°), 1598 on 2-lamp VP.•Specular low iridescence pre-anodized louver in VP model.•VR 9 cell unit meets IES RP-1 recommended criteria for lighting

VDT areas.•Candelas at Nadir (0°), 1224 on 2-lamp VR.•Semi-specular low iridescence pre-anodized louver in VR models.•Concealed spring-loaded latch/hinge can be opened either side.•Only 6" deep.•Louver frame with integral positive light stop.•Hold-down clips.•Protective film dust guard.•4” deep aluminum parabolic louver.

VPA2G16PR2FT120SB (Data)

VRA2G16LV2FT120SB (Data)

VPA2G12PP317120O3 (Data)

VRA2G9LP317120O3 (Data)

Options pages 150-156Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO.Magnetic Electronic PowerSpec Dimming40W TT5: BX 40W TT5: SB 40W TT5: PBT8: OC 50W TT5: BE T8: PS

55W TT5: BF (not avail. in 347V)T8: SO3 LPB T8: O3

T12 not available.LPB : Number of lamps per ballast.Drywall Kit For plaster frames, order Cat. No.: FK92X2 (2’ x 2’).Radio Interference Filter 120, 277 or 347 volt, 50 or 60 Hz. Suffix: R.Emergency Lighting System Suffix: O (e.g. VPA2G16PR2FT120SBO).Emergency battery pack with charger.(90 minutes at 15% of lumens for 1 lamp).Louver Finish Low iridescence specular is standard on VP models. Lowiridescence semi-specular is standard on VR models. Air Pattern Control and Air Slot Closure For horizontal and verticalair supply and to balance return air. Suffix: S.Static For static luminaires, replace A in the basic catalogue numberby S.

RCR C. U.1 662 613 554 505 466 427 388 359 3210 30

RCR C. U.1 572 523 484 435 396 367 328 299 2610 23

RCR C. U.1 682 633 584 535 496 457 418 379 3410 31

RCR C. U.1 692 633 584 535 486 447 408 379 3310 30

16 Cells

16 Cells

12 Cells

9 Cells

Recessed Luminaires ParabolicVision Smart 2’ x 2’ (VPA, VRA)4” Deep Cells • Air Handling/Static Luminaires

Page 14: LRG CFI

VPA2G16PR2FT 120 BX

VRA2G16LV2FT 120 SB

VPA2G12PP317 120 03

VRA2G9LP317 120 03

21

Type Cells Lamps Exposed Exposed Slot-T orqty/type T-Grid Concealed T-Grid

Air 16 2-TT5 VPA2G16PR2FT VPA2T16PR2FTHandling

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :4" Deep Precision 120 See page 20 See page 20Contoured Preanodized 277 Add appropriateAluminum Parabolic Louver 347 suffix to catalogue

number

Type Cells Lamps Exposed Exposed Slot-T orqty/type T-Grid Concealed T-Grid

Air 16 2-TT5 VRA2G16LV2FT VRA2T16LV2FTHandling

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :

Type Cells Lamps Exposed Exposed Slot-T orqty/type T-Grid Concealed T-Grid

Air 12 3-T8 VPA2G12PP317 VPA2T12PP317Handling

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :

Type Cells Lamps Exposed Exposed Slot-T orqty/type T-Grid Concealed T-Grid

Air 9 3-T8 VRA2G9LP317 VRA2T9LP317Handling

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :

*Average Footcandles Maintained Total LLF=.82 Reflectance: 80% Ceiling, 50% Wall, 20% Floor.

Recessed LuminairesParabolic

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 56 98 1.1

8' x 10' (80 sq ft/luminaire) 46 98 0.9

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 60 93 1.5

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 36 98 1.1

RE835 lamp rated at 3150 lumens

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 48 98 1.1

8' x 10' (80 sq ft/luminaire) 39 98 0.9

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 46 94 1.5

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 31 98 1.1

RE835 lamp rated at 3150 lumens

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 36 99 0.7

8' x 10' (80 sq ft/luminaire) 30 99 0.6

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 40 95 1.0

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 23 99 0.7

RE835 lamp rated at 1400 lumens

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 36 98 0.7

8' x 10' (80 sq ft/luminaire) 30 98 0.6

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 40 92 1.0

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 23 98 0.7

RE835 lamp rated at 1400 lumens

Reference Data

Efficiency 60.9%Spacing Ratio 1.7

LUMINOUS INTENSITY

55° 145cd65° 5cd75° 0cd85° 0cd

Electronic Ballast

Input Watts (120V) 74.0WBallast Factor .90

Reference Data

Efficiency 52.2%Spacing Ratio 1.8

LUMINOUS INTENSITY

55° 191cd65° 36cd75° 10cd85° 2cd

Electronic Ballast

Input Watts (120V) 74.0WBallast Factor .90

Reference Data

Efficiency 62.1%Spacing Ratio 1.4

LUMINOUS INTENSITY

55° 93cd65° 4cd75° 1cd85° 0cd

Electronic Ballast

Input Watts (120V) 47.0WBallast Factor .90

Reference Data

Efficiency 62.7%Spacing Ratio 1.4

LUMINOUS INTENSITY

55° 377cd65° 30cd75° 7cd85° 0cd

Electronic Ballast

Input Watts (120V) 47.0WBallast Factor .90

Page 15: LRG CFI

1521

1000

500

0

30°

60°

9 cells

6"(152 mm)

24" (610 mm)

24"(610 mm)

24" (610 mm)

16 cells

6"(152 mm)

24"(610 mm)

1737

1000

500

0

30°

60°

24" (610 mm)

9 cells

6"(152 mm)

24"(610 mm)

2442

2000

1000

0

30°

60°

24" (610 mm)

6"(152 mm)

2453

1000

500

0

30°

60°

24"(610 mm)

22

VRA 2’x 2’

VRA 2’x 2’

VRA 2’x 2’

Vision Smart architecturally symmetrical 2 x 2 VR Parabolics meet theBasic Criteria of IES RP-1 (except 9 cells, 3 x TT5). This luminaire deliversmedium to high levels with the best performance in terms of efficiency,wide spacing, and excellent glare control. The VR Series complieswith the Basic Criteria and is suited wherever use of VDTs is occasionalor non intensive.

Features•VR units meet IES RP-1 recommended criteria for lighting

VDT areas (except 9 cells, 3 x TT5).•Only 6" deep.•Specular low iridescence pre-anodized louver.•Concealed spring-loaded latch/hinge can be opened either side.•Louver frame with integral positive light stop.•Hold-Down clips.•Shipped with removable protective film dust guard.•4” deep aluminum parabolic louver.

VRA2G9LS26U120SO (Data)

VRA2G16LS26U120SO (Data)

VRA2G9LP32U120O3 (Data)

VRA2G12PP32U120O3 (Data)

Options pages 150-156Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO.Magnetic Electronic PowerSpec Dimming40W TT5: BX 40W TT5: SB 40W TT5: PBT8: OC 50W TT5: BE T8: PS

55W TT5: BF (not avail. in 347V)3 LPB TT5: X3T8: SO3 LPB T8: O3

LPB : Number of lamps per ballast. .Drywall Kit For plaster frames, order Cat. No.: FK92X2 (2’ x 2’).Radio Interference Filter 120, 277 or 347 volt, 50 or 60 Hz. Suffix: R.Emergency Lighting System Suffix: O (e.g. VRA2G9LS26U120SOO).Emergency battery pack with charger.(90 minutes at 15% of lumens for 1 lamp).Louver Finish Low iridescence semi-specular is standard.Air Pattern Control and Air Slot Closure For horizontal and verticalair supply and to balance return air. Suffix: S.Static For static luminaires, replace A in the basic catalogue numberby S.

RCR C. U.1 622 563 504 465 416 387 348 329 2910 27

RCR C. U.1 572 523 474 445 406 377 348 329 2910 27

RCR C. U.1 622 573 524 485 446 407 378 339 3010 27

RCR C. U.1 612 563 524 485 446 407 378 349 3010 28

9 Cells

16 Cells

9 Cells

12 Cells

Recessed Luminaires ParabolicVision Smart 2’ x 2’ (VRA)4” Deep Cells • Air Handling/Static Luminaires

PARABOLICS

VRA 2’x 2’

Page 16: LRG CFI

VRA2G9LS26U 120 SO

VRA2G16LS26U 120 SO

VRA2G9LP32U 120 03

VRA2G12PP32U 120 03

23

Type Cells Lamps Exposed Exposed Slot-T orqty/type T-Grid Concealed T-Grid

Air 9 2-T8U6 VRA2G9LS26U VRA2T9LS26UHandling

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :4" Deep Precision 120 See page 22 See page 22Contoured Preanodized 277 Add appropriateAluminum Parabolic Louver 347 suffix to catalogue

number

Type Cells Lamps Exposed Exposed Slot-T orqty/type T-Grid Concealed T-Grid

Air 16 2-T8U6 VRA2G16LS26U VRA2T16LS26UHandling

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :

Type Cells Lamps Exposed Exposed Slot-T orqty/type T-Grid Concealed T-Grid

Air 9 3-T8U1.6 VRA2G9LP32U VRA2T9LP32UHandling 9 3-TT5 VRA2G9LP3FT VRA2T9LP3FT

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :

Type Cells Lamps Exposed Exposed Slot-T orqty/type T-Grid Concealed T-Grid

Air 12 3-T8U1.6 VRA2G12PP32U VRA2T12PP32UHandling 12 3-TT5 VRA2G12PP3FT VRA2T12PP3FT

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :

*Average Footcandles Maintained Total LLF=.82 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens.

Recessed LuminairesParabolic

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 50 96 0.9

8' x 10' (80 sq ft/luminaire) 41 97 0.8

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 53 87 1.2

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 33 96 0.9

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 43 98 0.9

8' x 10' (80 sq ft/luminaire) 36 98 0.8

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 49 93 1.2

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 28 98 0.9

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 74 96 1.3

8' x 10' (80 sq ft/luminaire) 62 96 1.0

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 82 84 1.8

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 55 96 1.3

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 73 98 1.3

8' x 10' (80 sq ft/luminaire) 61 98 1.0

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 81 90 1.8

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 56 98 1.3

Reference Data

Efficiency 57.1%Spacing Ratio 1.3

LUMINOUS INTENSITY

55° 565cd65° 45cd75° 10cd85° 1cd

Electronic Ballast

Input Watts (120V) 60.0WBallast Factor .88

Reference Data

Efficiency 51.7%Spacing Ratio 1.2

LUMINOUS INTENSITY

55° 277cd65° 37cd75° 8cd85° 0cd

Electronic Ballast

Input Watts (120V) 60.0WBallast Factor .88

Reference Data

Efficiency 56.7%Spacing Ratio 1.4

LUMINOUS INTENSITY

55° 1009cd65° 80cd75° 19cd85° 1cd

Electronic Ballast

Input Watts (120V) 83.0WBallast Factor .92

Reference Data

Efficiency 55.5%Spacing Ratio 1.4

LUMINOUS INTENSITY

55° 229cd65° 13cd75° 5cd85° 2cd

Electronic Ballast

Input Watts (120V) 83.0WBallast Factor .92

Page 17: LRG CFI

1462

1000

500

0

30°

60°

48"(1219 mm)

5-1/2"(140 mm)

8" (203 mm)

16 Cells

5-1/2"(140 mm)

8" (203 mm)

16 Cells

5-1/2"(140 mm)

5-1/2"(140 mm)

48"(1219 mm)

1462

1000

500

0

30°

60°

10-13/16" (275 mm)

12" (305 mm)

32 Cells

48"(1219 mm)

4"(102 mm)

2340

2000

1000

0

30°

60°

24

ADS8G16MS132

ADS1G32MS232

16 Cells

16 Cells

32 Cells

ADS8G16MS132120SO (Data)

ADA8G16MS132120SO (Data)

ADS1G32MS232120SO (Data)

RCR C. U.1 672 633 584 545 506 467 438 399 3610 33

RCR C. U.1 672 633 584 545 506 467 438 399 3610 33

RCR C. U.1 682 633 584 535 496 457 428 399 3610 34

Features•Meets IES RP-1 Preferred Criteria.•Ideal for intensive VDT use areas.•Body 5-1/2" deep, 16 cell model.•Body 4" deep, 32 cell model.•Louver securely held with concealed torsionite spring clips.•Luminaire efficiency 62.4% (16 cell).•Luminaire efficiency 62% (32 cell).•Ceiling Compatability Exposed T-Grid G only.

Options pages 150-156Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO.Magnetic Electronic PowerSpec DimmingT8: OC T8: SO T8: PST12 not available.Drywall Kit For plaster frames, order Cat. No.: FK91X4 (1’ x 4’),FK907X4 (8” x 4’).Radio Interference Filter 120, 277 or 347 volt, 50 or 60 Hz. Suffix: R.Emergency Lighting System Suffix: O (e.g. ADS8G16MS132120SOO).Emergency battery pack with charger.(90 minutes at 15% of lumens for 1 lamp).Louver Finish Reflector matte low iridescence, pre-anodizedaluminum (standard). For other finishes, consult factory.

A unique one lamp luminaire that meets IES RP-1 prefered criteria witha smooth light distribution for 300 to 500 lux light levels.

Ultra shallow 4” (102 mm) 2-lamp luminaire that meets IES RP-1preferred criteria with a smooth light distribution for 300-700 lux lightlevels.

Recessed Luminaires ParabolicVision Smart 8” x 48”, 1’ x 4’ (ADS, ADA)Linear • Air Handling/Static Luminaires

PARABOLICS

ADS 8”x 48”

ADA 8”x 48”

ADS 1’x 4’

Page 18: LRG CFI

ADS8G16MS132 120 SO

ADA8G16MS132 120 SO

ADS1G32MS232 120 SO

5-1/2"(140 mm)

8 1/4"(210mm)

25*Average Footcandles Maintained Total LLF=BF (.88)x .85 = .75 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens.

Ceiling Tile

Self-flange ADS8L.

Type Luminaire Cells Lamp Cataloguesize qty/type number

Static 8" x 48" 16 1-T8 ADS8G16MS1328" x 48" 16 1-T5 28W ADS8G16MS1288" x 48" 16 1-T5 54W ADS8G16MS154

Static 8" x 48" 16 1-T8 ADS8L16MS132Self-flange 8" x 48" 16 1-T5 28W ADS8L16MS128

8" x 48" 16 1-T5 54W ADS8L16MS154

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :4" Deep Precision 120 See page 24 See page 24Contoured Preanodized 277 Add appropriateAluminum Parabolic Louver 347 suffix to catalogue

number

Type Luminaire Cells Lamp Cataloguesize qty/type number

Air Handling 8" x 48" 16 1-T8 ADA8G16MS1328" x 48" 16 1-T5 28W ADA8G16MS1288" x 48" 16 1-T5 54W ADA8G16MS154

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :

Type Luminaire Cells Lamp Cataloguesize qty/type number

Static 12" x 48" 32 2-T8 ADS1G32MS23212" x 48" 32 2-T5 28W ADS1G32MS22812" x 48" 32 2-T5 54W ADS1G32MS254

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :

Reference Data

Efficiency 62.4%Spacing Ratio 1.0

LUMINOUS INTENSITY

55° 5 cd65° 0 cd75° 0 cd85° 0 cd

Electronic Ballast

Input Watts (120V) 31.0WBallast Factor .88

Reference Data

Efficiency 62.0%Spacing Ratio 1.2

LUMINOUS INTENSITY

55° 4 cd65° 0 cd75° 0 cd85° 0 cd

Electronic Ballast

Input Watts (120V) 62.0WBallast Factor .88

Recessed LuminairesParabolic

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 6' (48 sq ft/luminaire) 33 99 0.6

8' x 8' (64 sq ft/luminaire) 25 99 0.5

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 26 99 0.6

8' x 8' x 8.5' Cubicle/60" Partition

8' x 6' (48 sq ft/luminaire) 21 99 0.6

Reference Data

Efficiency 62.4%Spacing Ratio 1.0

LUMINOUS INTENSITY

55° 5 cd65° 0 cd75° 0 cd85° 0 cd

Electronic Ballast

Input Watts (120V) 31.0WBallast Factor .88

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 6' (48 sq ft/luminaire) 33 99 0.6

8' x 8' (64 sq ft/luminaire) 25 99 0.5

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 26 99 0.6

8' x 8' x 8.5' Cubicle/60" Partition

8' x 6' (48 sq ft/luminaire) 21 99 0.6

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 46 99 1.0

8' x 10' (80 sq ft/luminaire) 39 99 0.8

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 46 99 1.3

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 31 99 1.0

Page 19: LRG CFI

1462

1000

500

0

30°

60°

12" (305 mm)

5-1/2"(140 mm)

6-1/4"(158 mm)

60"(1525 mm)

5-1/2"(140 mm)

6-1/4"(158mm)

12" (305 mm)

48"(1219 mm)

4"(102 mm)

10-13/16"(275 mm)

20" (508 mm)

60"(1525 mm)

2340

2000

1000

0

30°

60°

1462

1000

500

0

30°

60°

26

Recessed Luminaires ParabolicVision Smart 1’x 4’, 12”x 60”, 20”x 60”, 300mm x 1500mm, 500mm x 1500mmFaceplate • Imperial and Metric • Air Handling/Static Luminaires

Features•Meets IES RP-1 Preferred Luminance Criteria.•Ideal for intensive VDT use areas.•Body 5-1/2" deep, 16 cells model.•Body 4" deep, 32 cells model.•Faceplate made with die-formed 20 gauge steel with edges hemmed

for rigidity (DXA, DZA, DKA, DNA and DVA).•Full length 40” air slots with bent edge for rigidity (air

supply, return luminaire) (DXA, DZA, DKA, DNA and DVA).•Louver securely held with concealed torsionite spring clips.•Luminaire efficiency 62.4% (16 cell).•Luminaire efficiency 62% (32 cell).•Ceiling Compatability Exposed T-Grid G only.

Options pages 150-156Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO.Magnetic Electronic PowerSpec HDF DimmingT8: OC T8: SO T8: PS (not available in 347)T12 not available.Drywall Kit For plaster frames, order Cat. No.: FK91X4 (DZ),FK20X60 (DV-20” x 60”).Radio Interference Filter 120, 277 or 347 volt, 50 or 60 Hz. Suffix: R.Emergency Lighting System Suffix: O (e.g. DXA1G16MS132120SOO).Emergency battery pack with charger. (90 minutes at 15% of lumens for 1lamp).Louver Finish Reflector matte low iridescence, pre-anodized aluminum(standard). For other finishes, consult factory. Static For static luminaires, replace A in the basic catalogue number by S.

DVS5G32MS232

DZA1G16MS132120S0 DXA1G16MS132120SO (Data)

DZA1G16MS132120SO (Data)

DVA5G32MS232120SO (Data)

RCR C. U.1 672 633 584 545 506 467 438 399 3610 33

RCR C. U.1 672 633 584 545 506 467 438 399 3610 33

RCR C. U.1 682 633 584 535 496 457 428 399 3610 34

DVA5G32MS232

A unique one lamp luminaire that meets IES RP-1 prefered criteria witha smooth light distribution for 300 to 500 lux light levels.

16 Cells

16 Cells

32 Cells

PARABOLICS

DZA 1’x 4’

DVA 20”x 60”

DXA 12”x 60”

Page 20: LRG CFI

DXA1G16MS132 120

1190 mm

16 Cell

1500 mm

140 mm

159 mm

163 mm

300 mm

105 mm

276 mm

279 mm

500 mm

32 Cell

1016 mm1500 mm

SO

DZA1G16MS132 120 SO

DVA5G32MS232 120 SO

27

Luminaire : Voltage : Ballast : Options :

Type Luminaire Cells Lamp Cataloguesize qty/type number

Air Handling 20" x 60" 32 2-T8 DVA5G32MS232

500mm x 1500mm 32 2-T8 DNA5G32MS232

Ordering Guide

Ordering Guide

Type Luminaire Cells Lamp Cataloguesize qty/type number

Air Handling 12" x 60" 16 1-T8 DXA1G16MS132

300mm x 1500mm 16 1-T8 DKA1G16MS132

Ordering Guide

Luminaire : Voltage : Ballast : Options :Vision Smart 120 See page 26 See page 2612” x 60” 277

347

Type Luminaire Cells Lamp Cataloguesize qty/type number

Air Handling 12" x 48" 16 1-T8 DZA1G16MS132

Luminaire : Voltage : Ballast : Options :

16 Cells

32 Cells

Recessed LuminairesParabolic

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

10' x 10' checkerboard 33 99 0.5(50 sq ft/luminaire)

8' x 8' (64 sq ft/luminaire) 25 99 0.5

10' x 15' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 27 99 0.6

Reference Data

Efficiency 62.4%Spacing Ratio 1.0

LUMINOUS INTENSITY

55° 5cd65° 0cd75° 0cd85° 0cd

Electronic Ballast

Input Watts (120V) 31.0WBallast Factor .88

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 6' (48 sq ft/luminaire) 33 99 0.6

8' x 8' (64 sq ft/luminaire) 25 99 0.5

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 26 99 0.6

Reference Data

Efficiency 62.4%Spacing Ratio 1.0

LUMINOUS INTENSITY

55° 5cd65° 0cd75° 0cd85° 0cd

Electronic Ballast

Input Watts (120V) 31.0WBallast Factor .88

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

10' x 10' checkerboard 63 99 1.0(50 sq ft/luminaire)

13.3' x 10' checkerboard 65 99 0.9(64 sq ft/luminaire)

10' x 15' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 52 99 1.2

Reference Data

Efficiency 62.0%Spacing Ratio 1.2

LUMINOUS INTENSITY

55° 4cd65° 0cd75° 0cd85° 0cd

Electronic Ballast

Input Watts (120V) 62.0WBallast Factor .90

300mm x 1500mmDK Series

500mm x 1500mmDN Series

*Average Footcandles Maintained Total LLF=BF (.88) x .85 = .75 Reflectance: 80% Ceiling, 50% Wall, 20% Floor. RE835 lamp rated at 3000 lumens

Page 21: LRG CFI

967

500

250

0

30°

60°12" (305 mm)

12 cells

6-5/8"(168 mm)

48"(1219 mm)

12" (305 mm)

24 cells

6-5/8"(168 mm)

48"(1219 mm) 2267

2000

1000

0

30°

60°

12" (305 mm)

12 cells

6-5/8"(168 mm)

48"(1219 mm)

60°

30°

817

1000

500

0

30°

60°

28

24 Cells

Recessed Luminaires ParabolicVision Smart 1’x 4’ (VPA, Asymmetric VPA)3” Deep Cells • Air Handling/Static Luminaires

Vision Smart 1' x 4' VP Parabolics meet the preferred criteria ofIES RP-1. This luminaire delivers low to medium light levels with the bestperformance in terms of efficiency, wide spacing, and excellent glarecontrol. Both 1 lamp and 2 lamp models are especially suited whereveruse of VDT’s is prolonged and intense. The 1 lamp model is ideal for VDTareas where there are no paper tasks and 20 to 30 footcandle lightlevels may be preferred. The Asymmetric 1' x 4' is for lighting wallsadjacent to perimeter fixtures and eliminates “cave” effect caused bysharp cut-off luminaires.

Features•Meets IES RP-1 preferred for lighting VDT areas.•Vertical grain on louver eliminates reflected lamp images on cross

baffle.•Asymmetric side baffle and semi-specular aluminum upper reflector

(Asymmetric 1 lamp unit only).•Louver frame with positive light stop.•Spring-loaded latches (self-centering).•Only 6-5/8" deep.•Black housing exterior for cooler ballast operating temperature.•Hold-Down clip (pat. No. 5,072,344).•3” deep aluminum parabolic louver.

VPA1G12PR132120SO (Data)

VPA1G24PS232120SO (Data)

VPA1G12PA132120SO (Data)

VPA 1’x 4’

VPA 1’x 4’

Asymmetric VPA 1’x 4’

Options pages 150-156Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO.Magnetic Electronic PowerSpec DimmingT8: OC T8: SO T8: PS

(not avail. in 347V)T12 not available.Drywall Kit For plaster frames, order Cat. No.: FK91X4 (1’ x 4’).Radio Interference Filter 120, 277 or 347 volt, 50 or 60 Hz. Suffix: R.Emergency Lighting System Suffix: O (e.g. VPA1G12PR132120SOO).Emergency battery pack with charger.(90 minutes at 15% of lumens for 1 lamp).Louver Finish Low iridescence specular is standard on VP models.Consult factoy for other finishes.Air Pattern Control and Air Slot Closure For horizontal and verticalair supply and to balance return air. Suffix: S.Static For static luminaires, replace A in the basic catalogue numberby S.

RCR C. U.1 792 733 674 615 566 527 478 439 3810 35

RCR C. U.1 682 633 584 545 496 467 428 399 3510 33

12 Cells

12 Cells

PARABOLICS

Hold-Down clip installedHold-Down clip

before installation

Page 22: LRG CFI

VPA1G12PR132 120 SO

VPA1G24PS232 120 SO

VPA1G12PA132 120 SO

29*Average Footcandles Maintained Total LLF=.82 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens.

Spacing

MH 4' 5' 6' 7' 8' 9' 10' 11' 12' 13' 14' 15' 16' 17' 18' 19' 20'

9.50 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4

8.50 23 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24

7.50 22 24 24 25 25 25 25 25 25 25 25 25 25 25 25 25 25

6.50 24 26 28 28 28 28 28 28 28 28 28 28 28 28 28 28 28

5.50 23 26 27 28 28 28 28 28 28 28 28 28 28 28 28 28 28

4.50 19 21 22 23 24 24 24 24 24 24 24 24 24 24 24 24 24

3.50 15 16 18 18 19 19 20 20 20 20 20 20 20 20 20 19 19

2.50 12 14 14 15 16 16 16 16 17 17 17 17 17 16 16 16 16

1.50 10 11 12 12 13 13 13 13 14 14 14 14 14 13 13 13 13

0.50 9 10 10 11 11 11 12 12 12 12 12 12 12 12 12 11 11

Type Cells Lamps Exposed Slot-T orqty/type T-Grid Concealed T

Air 12 1-T8 VPA1G12PR132 VPA1T12PR132Handling

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :Vision Smart 120 See page 28 See page 283" Deep Parabolic 277 Add appropriate

347 suffix to catalogue number

Basic catalogue number : Voltage : Ballast : Options :

Basic catalogue number : Voltage : Ballast : Options :

Type Cells Lamps Exposed Slot-T orqty/type T-Grid Concealed T

Air 24 2-T8 VPA1G24PS232 VPA1T24PS232Handling

Ordering Guide

Type Cells Lamps Exposed Slot-T orqty/type T-Grid Concealed T

Air 12 1-T8 VPA1G12PA132 VPA1T12PA132Handling

Ordering Guide

Recessed LuminairesParabolic

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 32 95 0.5

8' x 10' (80 sq ft/luminaire) 26 96 0.4

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 31 93 0.6

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 16 98 0.5

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 48 94 1.0

8' x 10' (80 sq ft/luminaire) 40 84 0.8

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 51 96 1.3

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 31 94 0.8

Reference Data

Efficiency 72.0%Spacing Ratio 1.6

LUMINOUS INTENSITY

55° 65cd65° 0cd75° 0cd85° 0cd

Electronic Ballast

Input Watts (120V) 30WBallast Factor .88

Reference Data

Efficiency 61.5%Spacing Ratio 1.1

LUMINOUS INTENSITY

55° 114cd65° 5cd75° 1cd85° 0cd

Electronic Ballast

Input Watts (120V) 62WBallast Factor .88

Page 23: LRG CFI

649

250

500

0

30°

60°12" (305 mm)

8 cells 12 cells

6-5/8"(168 mm)

48"(1219 mm)

12" (305 mm)

6-5/8"(168 mm)

1687

1000

500

0

30°

60°

12" (305 mm)

6-5/8"(168 mm)

12" (305 mm)

6-5/8"(168 mm)

927

500

250

0

30°

60°

30

24 cells

48"(1219 mm)

8 cells

12 cells

48"(1219 mm)

48"(1219 mm)

24 Cells

Recessed Luminaires ParabolicVision Smart, Stacklyte 1’x 4’ (VRA, STA)3” Deep Cells • Air Handling/Static Luminaires

Vision Smart (VR) luminaires 1 lamp 8 cell, 2 lamp 12 cell comply withthe Basic Criteria of RP-1 and are suited for use in VDT areas. The 1 lampmodel is ideal for VDT areas with task/ambient lighting and 20 to 30footcandle light levels may be preferred. Stacklyte (STA) is excellent forlighting library bookshelves with 97.5% of the luminaire distribution inthe 0°-60° zone. This achieved with a 95% reflective specular reflector.

FeaturesMeets IES RP-1 recommended (minimum requirements) for lighting VDTareas (VR 1 lamp 8 and 12 cell, 2 lamp 12 cell)• Semi-specular low iridescence pre-anodized louver.• Vertical grain on louver eliminates reflected lamp images on cross

baffle.• Louver frame with positive light stop.• Spring-loaded latches (self centering).• Black housing exterior for cooler ballast operating temperature.• Turned-in edges for safe handling.•3” deep aluminum parabolic louver.

VRA1G8LS132120SO (Data)

VRA1G24LS232120SO (Data)

STA1G8LR132120SO (Data)

VRA 1’x 4’

VRA 1’x 4’

Stacklyte STA 1’x 4’

Options pages 150-156Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO.Magnetic Electronic PowerSpec DimmingT8: OC T8: SO T8: PS

(not avail. in 347V)Drywall Kit For plaster frames, order Cat. No.: FK91X4 (1’ x 4’).Radio Interference Filter 120, 277 or 347 volt, 50 or 60 Hz. Suffix: R.Emergency Lighting System Suffix: O (e.g. VRA1G8LS132120SOO).Emergency battery pack with charger.(90 minutes at 15% of lumens for 1 lamp).Louver Finish Low iridescence semi-specular is standard. Consultfactoy for other finishes.Air Pattern Control and Air Slot Closure For horizontal and verticalair supply and to balance return air. Suffix: S.Static For static luminaires, replace A in the basic catalogue numberby S.

RCR C. U.1 732 663 604 545 486 437 398 349 3010 27

8 Cells 12 Cells

12 Cells

8 Cells

RCR C. U.1 612 563 514 475 426 397 358 329 2910 27

PARABOLICS

Page 24: LRG CFI

VRA1G8LS132 120 SO

VRA1G24LS232 120 SO

STA1G12LR232 120 SO

31

VERTICAL FOOTCANDLES ON BOOK SHELVESCeiling 1' 2' 3' 4'

1.00 48 48 49 48 48 48 49 48 482.00 36 36 36 36 36 36 36 36 363.00 28 28 28 28 28 28 28 28 284.00 24 24 24 24 24 24 24 24 245.00 21 21 21 21 21 21 21 21 216.00 18 18 18 18 18 18 18 18 187.00 16 16 16 16 16 16 16 16 168.00 16 16 16 16 16 16 16 16 169.00 15 15 15 15 15 15 15 15 15

10.00 14 14 14 14 14 14 14 14 1411.00 12 12 12 12 12 12 12 12 1212.00 10 10 10 10 10 10 10 10 10

0' 1' 2' 3' 4'Book shelf aisle width, 36"

Floor

*Application Data

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 30 89 0.5

8' x 10' (80 sq ft/luminaire) 25 90 0.4

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 29 87 0.6

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 15 91 0.5

*Application Data

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 39 81 1.0

8' x 10' (80 sq ft/luminaire) 33 82 0.8

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 41 71 1.3

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire 25 83 1.0

Reference Data

Efficiency 67.9%Spacing Ratio 1.9

LUMINOUS INTENSITY

55° 548cd65° 65cd75° 17cd85° 5cd

Electronic Ballast

Input Watts (120V) 30WBallast Factor .88

Reference Data

Efficiency 50%Spacing Ratio 1.1

Electronic Ballast

Input Watts (120V) 62WBallast Factor .88

* Average Footcandles Maintained Total LLF=.82 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens.

Recessed LuminairesParabolic

Basic catalogue number : Voltage : Ballast : Options :Vision Smart 1’ x 4’ 120 See page 30 See page 30

277 Add appropriate347 suffix to catalogue

number

Basic catalogue number : Voltage : Ballast : Options :

Basic catalogue number : Voltage : Ballast : Options :

Type Cells Lamps Exposed Slot-T orqty/type T-Grid Concealed T

Air 8 1-T8 VRA1G8LS132 VRA1T8LS132Handling 12 1-T8 VRA1G12LW132 VRA1T12LW132

8 2-T8 VRA1G8LS232 VRA1T8LS23212 2-T8 VRA1G12LW232 VRA1T12LW232

Ordering Guide

Type Cells Lamps Exposed Slot-T orqty/type T-Grid Concealed T

Air 24 2-T8 VRA1G24LS232 VRA1T24LS232Handling

Ordering Guide

Type Cells Lamps Exposed Slot-T orqty/type T-Grid Concealed T

Air 8 1-T8 STA1G8LR132 STA1T8LR132Handling 8 2-T8 STA1G8LR232 STA1T8LR232

12 1-T8 STA1G12LR132 STA1T12LR13212 2-T8 STA1G12LR232 STA1T12LR232

Ordering Guide

Page 25: LRG CFI

24" (610 mm)

12 Cells

5"(127 mm)

48"(1219 mm)

1800

2400 0°

1200

600

0

30°

60°

24" (610 mm)

5"(127 mm)

18 Cells

48"(1219 mm)

2502

2000

1000

0

30°

60°

24" (610 mm)

5"(127 mm)

18 Cells 24 Cells

48"(1219 mm)

2620

2000

1000

0

30°

60°

24" (610 mm)

5"(127 mm)

32 Cells

48"(1219 mm)

3182

2000

1000

0

30°

60°

32

RCR C. U.1 692 623 564 505 456 417 378 349 3210 29

12 Cells

18 Cells

18 Cells 24 Cells

32 Cells

Recessed Luminaires ParabolicDeepcel Series 2’ x 4’ (DPA)3” Deep Cells • Air Handling/Static Luminaires

Lightolier Deepcel is the industry standard 3" parabolic louver trofferwith features that offer value above the industry standard. Deepcelhousings have a clean white interior without holes or bends. Blackpainted exteriors reduce heat build-up within the lamp/ballast compart-ment(s) for optimum lamp and ballast efficiency. 24 cell configurationmeets IES RP-1 recommended (basic) criteria for VDT areas.

Features•Only 5" deep.•Vertical grain on louver eliminates reflected lamp image on cross baffle.•Spring-loaded latches.•Mitered aluminum louver flange.•3 lamp, 18 cell (77.7% efficient).•1.6 spacing to mounting height ratio.•Snap-in ballast cover.•Louver has polyethylene dust guard.•Black exterior finish for cooler ballast operation.•24 cell louver configuration meets IES RP-1 recommended (basic) for

VDT applications (3-T8 only).•Built-in Hold-Down clip.•3" deep aluminum parabolic louver.•Available in in T8, T5 and T5HO combinations.

DPA2G12LS232120SO (Data)

DPA2G18LS332120O3 (Data)

DPA2G18LP332120O3 (Data)

DPA2G32LS432120O4 (Data)

Options pages 150-156Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO.Magnetic Electronic PowerSpec DimmingT8: OC T8: SO T8: PS

T5/T5HO: PG3 LPB T5/T5HO: PU (not avail. in 347V)4 LPB T5/T5HO: PV

LPB : Number of lamps per ballast. Drywall Kit For plaster frames, order Cat. No.: FK92X4 (2’ x 4’).Radio Interference Filter 120, 277 or 347 volt, 50 or 60 Hz. Suffix: R.Emergency Lighting System Suffix: O (e.g. DPA2G12LS232120SOO).Emergency battery pack with charger.(90 minutes at 15% of lumens for 1 lamp).Louver Finish Low iridescence semi-specular is standard. Except DPA24 cells : Low iridescence specular. Consult factoy for other finishes.Air Pattern Control and Air Slot Closure For horizontal and verticalair supply and to balance return air. Suffix: S.Static For static luminaires, replace A in the basic catalogue numberby S.

RCR C. U.1 852 763 674 595 536 487 438 399 3610 33

RCR C. U.1 832 743 664 595 536 487 438 409 3610 33

RCR C. U.1 842 753 674 605 546 497 448 409 3710 34

PARABOLICS

DPA 2’x 4’

DPA 2’x 4’

DPA 2’x 4’

DPA 2’x 4’

Page 26: LRG CFI

DPA2G12LS232 120 SO

DPA2G18LS332 120 03

DPA2G18LP332 120 03

DPA2G32LS432 120 04

33

Basic catalogue number : Voltage : Ballast : Options :3" Deep Precision 120 See page 32 See page 32Contoured Preanodized 277 Add appropriateAluminum Parabolic Louver 347 suffix to catalogue

number

Basic catalogue number : Voltage : Ballast : Options :

Basic catalogue number : Voltage : Ballast : Options :

Basic catalogue number : Voltage : Ballast : Options :

Ordering Guide

Ordering Guide

Ordering Guide

Ordering Guide

Recessed LuminairesParabolic

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 69 92 0.9

8' x 10' (80 sq ft/luminaire) 56 93 0.8

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 66 80 1.2

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 36 92 0.9

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 102 92 1.3

8' x 10' (80 sq ft/luminaire) 84 93 1.1

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 85 79 1.8

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 55 92 1.3

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 100 92 1.3

8' x 10' (80 sq ft/luminaire) 82 93 1.1

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 97 79 1.8

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 56 92 1.3

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 109 93 1.8

8' x 10' (80 sq ft/luminaire) 90 94 1.4

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 112 79 2.3

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 67 93 1.8

Reference Data

Efficiency 77.6%Spacing Ratio 1.6

Electronic Ballast

Input Watts (120V) 85.0WBallast Factor .88

Reference Data

Efficiency 77.7%Spacing Ratio 1.6

Electronic Ballast

Input Watts (120V) 85.0WBallast Factor .88

Reference Data

Efficiency 64.1%Spacing Ratio 1.4

Electronic Ballast

Input Watts (120V) 112.0WBallast Factor .88

Reference Data

Efficiency 80.0%Spacing Ratio 2.0

Electronic Ballast

Input Watts (120V) 62.0WBallast Factor .88

*Average Footcandles Maintained Total LLF=.82 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens.

Type Cells Lamps Exposed Slot-T orqty/type T-Grid Concealed T

Air 12 2-T8 DPA2G12LS232 DPA2T12LS232Handling 12 2-T5 DPA2G12LS228 DPA2T12LS228

12 2-T5HO DPA2G12LS254 DPA2T12LS254

Type Cells Lamps Exposed Slot-T orqty/type T-Grid Concealed T

Air 18 3-T8 DPA2G18LS332 DPA2T18LS332Handling 18 4-T8 DPA2G18LS432 DPA2T18LS432

18 3-T5 DPA2G18LS328 DPA2T18LS32818 3-T5HO DPA2G18LS354 DPA2T18LS35418 4-T5 DPA2G18LS428 DPA2T18LS42818 4-T5HO DPA2G18LS454 DPA2T18LS454

Type Cells Lamps Exposed Slot-T orqty/type T-Grid Concealed T

Air 18 3-T8 DPA2G18LP332 DPA2T18LP332Handling 24 3-T8 DPA2G24PP332 DPA2T24PP332

18 3-T5 DPA2G18LP328 DPA2T18LP32818 3-T5HO DPA2G18LP354 DPA2T18LP35424 3-T5 DPA2G24PP328 DPA2T24PP32824 3-T5HO DPA2G24PP354 DPA2T24PP354

Type Cells Lamps Exposed Slot-T orqty/type T-Grid Concealed T

Air 32 4-T8 DPA2G32LS432 DPA2T32LS432Handling 32 4-T5 DPA2G32LS428 DPA2T32LS428

32 4-T5HO DPA2G32LS454 DPA2T32LS454

Page 27: LRG CFI

34

1552

1000

500

0

30°

60°24" (610 mm)

5"(127 mm)

24"(610 mm)

24" (610 mm)

5"(127 mm)

24"(610 mm)

2102

1000

500

0

30°

60°

24" (610 mm)

5"(127 mm)

24"(610 mm)

3014

1000

500

0

30°

60°

24" (610 mm)

5"(127 mm)

24"(610 mm)

1573

1000

500

0

30°

60°

9 Cells 12 Cells

9 Cells 12 Cells

9 Cells 12 Cells

16 Cells

Recessed Luminaires ParabolicDeepcel Series 2’ x 2’ (DPA)3” Deep Cells • Air Handling/Static Luminaires

Deepcel 2 x 2 parabolic troffers feature all of the design benefits of the2 x 4 product. Available with T12, T8 and TT5 type lamps in 9 or 16 cellconfigurations, Deepcel 2 x 2 is only 5" deep and is fast becoming thepreferred choice in performance lighting specifications for general officelighting.

Features•Only 5" deep.•3" deep aluminum parabolic louver.•Vertical grain on louver eliminates reflected lamp image on cross baffle.•2 lamp, 9 cell T8U6 (66.2% efficient).•3 lamp, 9 cell TT5 (72.0% efficient).•Spring-loaded latches.•Mitered aluminum louver flange.•Snap-in ballast cover.•Louver has polyethylene dust guard.•Black exterior finish for cooler ballast operation.•3" deep aluminum parabolic louver.

DPA2G9LS26U120SO (Data)

DPA2G9LP32U120O3 (Data)

DPA2G9LP3FT120X3 (Data)

DPA2G16LS26U120SO (Data)

Options pages 150-156Ballast Specify voltage (120, 277 or 347) add suffix, e.g. 120SO.Magnetic Electronic PowerSpec Dimming40W TT5: BX 40W TT5: SB 40W TT5: PBT8: OC 50W TT5: BE T8: PS

55W TT5: BF (not avail. in 347V)3 LPB 40W TT5: X3T8: SO3 LPB T8: O3

LPB : Number of lamps per ballast. Drywall Kit For plaster frames, order Cat. No.: FK92X2 (2’ x 2’).Radio Interference Filter 120, 277 or 347 volt, 50 or 60 Hz. Suffix: R.Emergency Lighting System Consult CFI Fluorecent Representative.Louver Finish Low iridescence semi-specular is standard. Consultfactoy for other finishes.Air Pattern Control and Air Slot Closure For horizontal and verticalair supply and to balance return air. Suffix: S.Static For static luminaires, replace A in the basic catalogue numberby S.

RCR C. U.1 712 633 564 505 456 417 378 349 3110 29

RCR C. U.1 682 623 564 505 456 407 368 329 2910 26

RCR C. U.1 782 703 634 575 516 477 438 399 3610 33

RCR C. U.1 662 603 544 485 446 407 368 339 3110 28

PARABOLICS

DPA 2’x 2’

DPA 2’x 2’

DPA 2’x 2’

DPA 2’x 2’

Page 28: LRG CFI

DPA2G9LS26U 120 SO

DPA2G9LP32U 120 03

DPA2G9LP3FT 120 X3

DPA2G16LS26U 120 SO

35

Basic catalogue number : Voltage : Ballast : Options :3” Deep Precision 120 See page 34 See page 34Contoured Preanodized 277 Add appropriateAluminum Parabolic Louver 347 suffix to catalogue

number

Basic catalogue number : Voltage : Ballast : Options :

Basic catalogue number : Voltage : Ballast : Options :

Basic catalogue number : Voltage : Ballast : Options :

Type Cells Lamps Exposed Slot-T orqty/type T-Grid Concealed T

Air 9 2-T8U6 DPA2G9LS26U DPA2T9LS26UHandling 12 2-T8U6 DPA2G12LS26U DPA2T12LS26U

Ordering Guide

Type Cells Lamps Exposed Slot-T orqty/type T-Grid Concealed T

Air 9 3-T8U1.6 DPA2G9LP32U DPA2T9LP32UHandling 12 3-T8U1.6 DPA2G12LP32U DPA2T12LP32U

Ordering Guide

Type Cells Lamps Exposed Slot-T orqty/type T-Grid Concealed T

Air 9 3-TT5 DPA2G9LP3FT DPA2T9LP3FTHandling 12 3-TT5 DPA2G12LP3FT DPA2T12LP3FT

Ordering Guide

Type Cells Lamps Exposed Slot-T orqty/type T-Grid Concealed T

Air 16 2-T8U6 DPA2G16LS26U DPA2T16LS26UHandling

Ordering Guide

Recessed LuminairesParabolic

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 57 89 0.9

8' x 10' (80 sq ft/luminaire) 47 90 0.8

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 57 72 1.2

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 34 89 0.9

RE835 lamp rated at 3000 lumens

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 79 85 1.3

8' x 10' (80 sq ft/luminaire) 65 86 1.0

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 80 64 1.8

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 48 85 1.3

RE835 lamp rated at 2900 lumens

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 98 91 1.6

8' x 10' (80 sq ft/luminaire) 81 92 1.3

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 100 74 2.1

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 62 91 1.6

RE835 lamp rated at 3150 lumens

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 53 95 0.9

8' x 10' (80 sq ft/luminaire) 44 96 0.8

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 56 85 1.2

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 35 95 0.9

RE835 lamp rated at 3000 lumens

Reference Data

Efficiency 66.2%Spacing Ratio 1.2

Electronic Ballast

Input Watts (120V) 60.0WBallast Factor .88

Reference Data

Efficiency 63.4%Spacing Ratio 1.4

Electronic Ballast

Input Watts (120V) 83.0WBallast Factor .92

Reference Data

Efficiency 72.0%Spacing Ratio 1.5

Electronic Ballast

Input Watts (120V) 103.0WBallast Factor .90

Reference Data

Efficiency 61.6%Spacing Ratio 1.3

Electronic Ballast

Input Watts (120V) 60.0WBallast Factor .88

*Average Footcandles Maintained Total LLF=.82 Reflectance: 80% Ceiling, 50% Wall, 20% Floor.

Page 29: LRG CFI

1634

1000

500

0

30°

60°24" (610 mm)

12 ll

5-1/2"(140 mm)

48"(1219 mm)

24" (610 mm)

5-1/2"(140 mm)

48"(1219 mm)

2444

2000

1000

0

30°

60°

36

18Cells

12 Cells

24Cells

Recessed Luminaires ParabolicParalyte 2448 2’ x 4’ (PLA)3” Deep Cells • Air Return Luminaires

Features•2 lamp, 12 cell (78.9% efficient).•3 lamp, 18 cell (73.3% efficient).•Full 23" x 47" aluminum parabolic louver.•Low iridescence, semi-specular aluminum, standard.•Vertical grain louver eliminates reflected lamp image on cross baffle.•One luminaire fits 50 lay-in G type and Slot Grid type ceiling systems.•Only 5-1/2" deep housing.•Individual lamp compartments.•Spring-loaded latches.•Shipped with removable polyethylene dust guard to protect louver.•Captive bolt ballast mounting.•Capable of returning up to 300 CFM at .05 negative static pressure

depending on ceiling system.•3” deep aluminum parabolic louver.

PLA2G12LS232120SO (Data)

PLA2G18LP332120O3 (Data)

Options pages 150-156Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO.Magnetic Electronic PowerSpec DimmingT8: OC T8: SO T8: PS

3 LPB T8: O3 (not avail. in 347V)4 LPB T8: O4

LPB : Number of lamps per ballast.

Radio Interference Filter 120, 277 or 347 volt, 50 or 60 Hz. Suffix: R.Emergency Lighting System Suffix: O (e.g. PLA2G12LS232120SOO).Emergency battery pack with charger.(90 minutes at 15% of lumens for 1 lamp).Louver Finish Low iridescence semi-specular is standard. Consultfactoy for other finishes.One Luminaire Fits All These Ceiling Types

narrow grid system.slot grid.standard grid.two-directional concealed grid.

Paralyte 2’ x 4’ luminaires are highly efficient, more so than virtually anycomparable parabolic luminaire because of the greater width of theoptical chamber. Paralyte luminaries are suitable for a wide variety ofapplications, especially merchandising and showroom lighting whereceilings are high and maximum light output is required. 23" x 47" louvereliminates black reveal in standard grid ceilings and has only 1/4" revealin slot or narrow grid ceilings. (NOT for continuous row mounting.)

Automatic locking and adjustableleveling from outside or inside theluminaire.

Capable of returning up to 300 CFM at .05 negative staticpressure depending on ceiling system.

RCR C. U.1 852 763 684 605 546 487 438 389 3410 30

RCR C. U.1 792 713 644 585 526 467 428 379 3410 30

Hold-Down ClipP

ARABOLICS

PLA 2’x 4’

PLA 2’x 4’

Page 30: LRG CFI

PLA2G12LS232 120 SO

PLA2G18LP332 120 03

37

Recessed LuminairesParabolic

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 67 92 0.9

8' x 10' (80 sq ft/luminaire) 56 92 0.8

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 65 78 1.2

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 36 99 0.9

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 94 89 1.3

8' x 10' (80 sq ft/luminaire) 78 90 1.1

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 93 77 1.8

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 55 97 1.3

Type Cells Lamps CatalogueQty/Type Number

Air 12 2-T8 PLA2G12LS232Return

Ordering GuideReference Data

Efficiency 78.9%Spacing Ratio 1.6

Electronic Ballast

Input Watts (120V) 62.0WBallast Factor .88

Reference Data

Efficiency 73.3%Spacing Ratio 1.5

Electronic Ballast

Input Watts (120V) 85.0WBallast Factor .88

Basic catalogue number : Voltage : Ballast : Options :3” Deep Precision 120 See page 36 See page 36Contoured Preanodized 277 Add appropriateAluminum Parabolic Louver 347 suffix to catalogue

number

Not for continuous row mounting

Type Cells Lamps Catalogueqty/type number

Air 18 3-T8 PLA2G18LP332Return 18 4-T8 PLA2G18LS432

Ordering Guide

Not for continuous row mounting.

Basic catalogue number : Voltage : Ballast : Options :

*Average Footcandles Maintained Total LLF=.82 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens.

Mounting Method

Narrow Grid System Slot Grid Standard Grid Two Directional Concealed Grid

Page 31: LRG CFI

24"(610 mm)

1482

1000

500

0

30°

60°24" (610 mm)

5-1/2"(140 mm)

24"(610 mm)

24" (610 mm)

5-1/2"(140 mm)

2470

2000

1000

0

30°

60°

24" (610 mm)

5-1/2"(140 mm)

24"(610 mm)

1389

1000

500

0

30°

60°

38

T8U1.6:

TT5:

9 Cells

9 Cells

16 Cells

Recessed Luminaires ParabolicParalyte 2424 2’ x 2’ (PLA)3” Deep Cells • Air Return Luminaires

Architecturally symmetric Paralyte 2’ x 2’ luminaires are the first choicefor department stores, specialty shop and designer showroom lighting.Up to 3 TT5 type lamps or T8U1.6 lamps can be accommodated in thisluminaire with 9 cell louvers for high light output. 23" x 23"louver eliminates black reveal in standard grid ceilings and has only 1/4"reveal in slot or narrow grid ceilings. (NOT for continuous row mounting.)

Features•2U lamp, 9 cell (68.7% efficient).•9 cell 3 T8U1.6 lamps (72.6% efficient). 9 cell 3 TT5 lamps

(72.8% efficient). Either unit can provide the same lighting levels asan 18 cell, 3 lamps 2' x 4' parabolic without additional units.

•Full 23" square aluminum parabolic louver.•Non-directional in appearance.•Low-iridescence, semi-specular aluminum, standard.•3-1/8" deep louver.•Vertical grain on louver eliminates reflected lamp image

on cross baffle.•One luminaire fits 50 lay-in Grid and Slot Grid type ceiling systems.•Only 5-1/2" deep housing.•Automatic engaging hold-down clips.•Individual lamp compartments.•Black exterior finish for cooler ballast operation.•Spring-loaded latches.•Shipped with removable polyethylene dust guard to protect Louver.

PLA2G9LS26U120SO (Data)

PLA2G9LP32U120O3 (Data)

PLA2G16LS26U120SO (Data)

Options pages 150-156Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO.Magnetic Electronic PowerSpec DimmingT8: OC 3 LPB T8: O3 T8: PS

T8: SO (not avail. in 347V)LPB : Number of lamps per ballast.

Radio Interference Filter 120, 277 or 347 volt, 50 or 60 Hz. Suffix: R.Emergency Lighting System Consult CFI Fluorescent Representative.Louver Finish Low iridescence semi-specular is standard. Consultfactoy for other finishes.One Luminaire Fits All These Ceiling Types

narrow grid system.slot grid.standard grid.two-directional concealed grid.

RCR C. U.1 732 653 584 515 466 427 388 349 3210 29

RCR C. U.1 782 713 644 575 516 467 428 379 3310 30

RCR C. U.1 652 593 534 485 436 397 358 329 2810 26

Hold-Down Clip

Automatic locking and adjustableleveling from outside or inside theluminaire.

Capable of returning up to 175 CFM at .05 negative staticpressure depending on ceiling system.

PARABOLICS

PLA 2’x 2’

PLA 2’x 2’

PLA 2’x 2’

Page 32: LRG CFI

PLA2G9LS26U 120 SO

PLA2G9LP32U 120 03

PLA2G16LS26U 120 SO

39

Basic catalogue number : Voltage : Ballast : Options :3" Deep Precision 120 See page 38 See page 38Contoured Preanodized 277 Add appropriateAluminum Parabolic Louver 347 suffix to catalogue

number

Basic catalogue number : Voltage : Ballast : Options :

Basic catalogue number : Voltage : Ballast : Options :

Type Cells Lamps Catalogueqty/type number

Air 9 2-T8U6 PLA2G9LS26UReturn

Ordering Guide

Not for continuous row mounting.

Type Cells Lamps Catalogueqty/type number

Air 9 3-T8U1.6 PLA2G9LP32UReturn

Ordering Guide

Not for continuous row mounting.

Type Cells Lamps Catalogueqty/type number

Air 16 2-T8U6 PLA2G16LS26UReturn

Ordering Guide

Not for continuous row mounting.

Recessed LuminairesParabolic

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 59 85 0.9

8' x 10' (80 sq ft/luminaire) 49 86 0.8

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 58 67 1.2

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 35 85 0.9

RE835 lamp rated at 3000 lumens

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 91 79 1.3

8' x 10' (80 sq ft/luminaire) 76 80 1.0

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 91 60 1.8

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 55 79 1.3

RE835 lamp rated at 2900 lumens

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 51 92 0.9

8' x 10' (80 sq ft/luminaire) 43 93 0.8

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 53 81 1.2

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 33 92 0.9

RE835 lamp rated at 3000 lumens

Reference Data

Efficiency 68.7%Spacing Ratio 1.3

Electronic Ballast

Input Watts (120V) 60.0WBallast Factor .88

Reference Data

Efficiency 72.6%Spacing Ratio 1.5

Electronic Ballast

Input Watts (120V) 83.0WBallast Factor .92

Reference Data

Efficiency 59.9%Spacing Ratio 1.4

Electronic Ballast

Input Watts (120V) 60.0WBallast Factor .88

*Average Footcandles Maintained Total LLF=.82 Reflectance: 80% Ceiling, 50% Wall, 20% Floor.

Mounting Method

Narrow Grid System Slot Grid Standard Grid Two Directional Concealed Grid

Page 33: LRG CFI

2250

0

1500

750

0

30

60

2250

0

1500

750

0

30

60

40

9" (229mm)

6-1/8"(156mm)

6-1/2" (165mm)

9" (229mm)

6-1/8"(156mm)

6-1/2" (165mm)

Recessed Luminaires ParabolicLytecel - Individual 9”x 48” (LIA, LIS)Air Handling / Static Luminaires

Features• Narrow 6-1/2" wide louver openings • Meets IES RP1 for lighting VDT areas.• 65.2% efficient T8-1 light.• 61.0% efficient T8-2 light.• 1.5 and 1.4 spacing mounting ratio.• Specular, low iridescence, pre-anodized

aluminum louver.• Vertical grain on louver eliminates reflected

lamp image on cross baffle.• Louver frame with positive light stop.• Spring loaded latches (self centering).• Reversible louver hinging.• Louver has protective dust guard.• Only 6-1/8" deep body.• Black housing exterior for cooler ballast

operating temperature.• Turned-in edges for safe handling.• Air closure strips (optional).

Options pages 150-156Ballast Specify voltage (120, 277 or UNV) and type and add as suffix,e.g. 120SO

<20THD <10THDElectronic T8 SO* HI*LOL T8 Dimming PS –*Instant StartConsult factory for other wattages.Electrical/Wiring Options For special wiring, fusing, electronic dimming ballasts, consult factory.Fusing Internal fast-blow fusing. SUFFIX: F.Radio Interference Filter 120 or 277 volt, 50 or 60 Hz. One per fixture. SUFFIX: R.Air Closure Strips: Suffix: S (factory installed),

Cat no. ACS4 (Field installed).Drywall Kit Order catalog number FK99X4 with “G”type fixtures for drywall of plaster ceilings. This FK99X4 kit is only forLytecel individual mounts.

LIA9G12PR132120SO (Data)

LIA9G12PR232120SO (Data)

RCR C. U.1 732 693 644 605 566 537 498 469 4310 41

RCR C. U.1 692 653 604 575 536 507 468 449 4110 39

PARABOLICS

12 Cells

12 Cells

LIA 9“ x 48“

LIA 9“ x 48“

Lytecel 9 Continuous Louver

Lytecel 8 Continuous Louver

Page 34: LRG CFI

LIA9G12PR132 120 SO

LIS9G12PR232 120 SO

41

Recessed LuminairesParabolic

Basic catalogue number : Voltage : Ballast : Options :Lytecell Individual 120 See page 40 See page 409“ x 48“ 277 Add appropriate

347 suffix to catalogueUNV number

Basic catalogue number : Voltage : Ballast : Options :

Reference Data

Efficiency 65.2%Spacing Ratio 1.5

LUMINOUS INTENSITY

55° 47cd65° 5cd75° 3cd85° 2cd

Electronic Ballast

Input Watts (120V) 31.0WBallast Factor 0.88

Type Cells Lamps Exposed Exposed Slot-Tqty/type T-Grid Concealed T-Grid

Static 12 1-T8 LIS9G12PR132 LIS9T12PR132Air Handling 12 1-T8 LIA9G12PR132 LIA9T12PR132

Ordering Guide

Type Cells Lamp Exposed Exposed Slot-Tqty/type T-Grid Concealed T-Grid

Static 12 2-T8 LIS9G12PR232 LIS9T12PR232Air Handling 12 2-T8 LIA9G12PR232 LIA9T12PR232

Ordering Guide

Application Data*

Luminaire Spacing FC W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 25 0.45

8' x 10' (80 sq ft/luminaire) 20.9 0.45

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 37.4 1.08

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 28.8 1.08

Reference Data

Efficiency 61.0%Spacing Ratio 1.4

LUMINOUS INTENSITY

55° 90cd65° 12cd75° 6cd85° 4cd

Electronic Ballast

Input Watts (120V) 62.0WBallast Factor 0.88

Application Data*

Luminaire Spacing FC W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 30.4 0.56

8' x 10' (80 sq ft/luminaire) 26 0.56

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 21.3 0.51

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 27.2 0.87

*Average Footcandles Maintained Total LLF=BF (.88) x .85= .75 Reflectance: 80% Ceiling, 50% Wall, 20% Floor. RE835 lamp rated at 3000 lumens.

* For low iridescence semi-spectacular louver finish order LIA9G12LR132

* For low iridescence semi-spectacular louver finish order LIA9G12LR132

Page 35: LRG CFI

1200

0

800

400

0

30

60

2250

0

1500

750

0

30

60

42

9" (229mm)

6-1/8"(156mm)

6-1/2" (165mm)

9" (229mm)

6-1/8"(156mm)

6-1/2" (165mm)

6-1/8"(156mm)

T-Type 8" (203mm)6-1/2" (165mm)

6-1/8"(156mm)

T-Type 8" (203mm)6-1/2" (165mm)

Lytecel 9 Continuous

Lytecel 8 Continous

Lytecel 9 or Lytecel 8

1 Lamp 2 Lamp

Recessed Luminaires ParabolicLytecel - Continuous Row 9“x 48”, 8”x 48” (LCA, LCS)Air Handling / Static Luminaires

LCA9G12PR232120SO (Data)

LCS8G12PR232120SO (Data)

RCR C. U.1 692 653 604 575 536 507 468 449 4110 39

PARABOLICS

12 Cells

12 Cells

Lytecel Continuous is a unique versatile narrow recessed linearparabolic that can be used with a variety of ceiling systems to create uninterrupted lines of light with a continuous louver appearance for theentire row.

Lytecel will provide illumunination that meets IES RP-1 requirementsfor lighting VDT areas at low energy cost.

Features• Narrow 6-1/2" wide louver.• 48" long louver gives an uninterrupted louver appearance when row

mounted.• Meets IES RP1 for lighting VDT areas.• 61.0% efficient (T8) 2 light.• 65.2% efficient (T8) 1-light.• 1.5 and 1.4 spacing mounting ratio.• Specular, low iridescence, pre-anodized aluminum louver.• Vertical grain on cross blades eliminates reflected lamp image.• Spring loaded latches (self centering).• Reversible louver hinging.• Louver has protective dust guard.• Only 6-1/8" deep body.• Black housing exterior for cooler ballast operating temperature.• Turned-in edges for safe handling.• Air closure strips (optional).• 8” wide model only available in static.

Options pages 150-156Ballast Specify voltage (120, 277 or UNV) and type and add as suffix,e.g. 120SO

<20THD <10THDElectronic T8 SO* HI*LOL T8 Dimming PS –*Instant StartConsult factory for other wattages.Electrical/Wiring Options For special wiring, fusing, electronic dimming ballasts, consult factory.Fusing Internal fast-blow fusing. SUFFIX: F.Radio Interference Filter 120 or 277 volt, 50 or 60 Hz. One per fixture. SUFFIX: R.Air Closure Strips: Suffix: S (factory installed),

Cat no. ACS4 (Field installed).

Lytecel 9 Continuous Louver

Lytecel 8 Continuous Louver

Page 36: LRG CFI

LCA9G12PR232 120 SO

LCS8G12PR232 120 SO

43

Basic catalogue number : Voltage : Ballast : Options :

Type Cells Lamp 15/16 9/16 Exposed Slot-Tqty/ Grid Grid or type Concealed T

Static 12 2-T8 LCS8G12PR232 LCS8N12PR232 LCS8T12PR232Static 12 1-T8 LCS8G12PR132 LCS8N12PR132 LCS8T12PR132

Each fixture is 4' in length and can be run in any desired row length of 4' increments.

Ordering Guide

*Average Footcandles Maintained Total LLF=BF (.88) x .85= .75 Reflectance: 80% Ceiling, 50% Wall, 20% Floor. RE835 lamp rated at 3000 lumens.

Recessed LuminairesParabolic

Basic catalogue number : Voltage : Ballast : Options :Lytecell 9 Continuous 120 See page 42 See page 42

277 Add appropriate347 suffix to catalogueUNV number

Reference Data

Efficiency 65.2%Spacing Ratio 1.5

LUMINOUS INTENSITY

55° 47cd65° 5cd75° 3cd85° 2cd

Electronic Ballast

Input Watts (120V) 31.0WBallast Factor 0.88

Type Cells Lamps Exposed Exposed Slot-Tqty/type T-Grid Concealed T-Grid

Static 12 1-T8 LCS9G12PR132 LCS9T12PR132Air Handling 12 2-T8 LCS9G12PR232 LCA9T12PR232

12 1-T8 LCA9G12PR132 LCA9T12PR13212 2-T8 LCA9G12PR232 LCA9T12PR232

Each fixture is 4' in length and can be run in any desired row length of 4' increments.

Ordering GuideApplication Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 30.4 0.56

8' x 10' (80 sq ft/luminaire)

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire)

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire)

Reference Data

Efficiency 61.0%Spacing Ratio 1.4

LUMINOUS INTENSITY

55° 90cd65° 12cd75° 6cd85° 4cd

Electronic Ballast

Input Watts (120V) 62.0WBallast Factor 0.88

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire)

8' x 10' (80 sq ft/luminaire)

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire)

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire)

* For low Iridescence Semi-Spectacular louver finish order LCA9G12LR132

* For low Iridescence Semi-Spectacular louver finish order LCS8G12LR132

Page 37: LRG CFI

250

1239

750

0

30°

60°

(1016 mm)(1525 mm)60" 40"

20" (508mm)

15-5/8"(397mm)

6-1/2"(165mm)

(1016 mm)(1525 mm)

6-1/2"(165mm)

20" (508mm)

15-5/8"(397mm)

40"60"1535

1000

500

0

30°

60°

(1016 mm)(1525 mm)60" 40"

20" (508mm)

15-5/8"(397mm)

6-1/2"(165mm)

1131

1500

500

0

30°

60°

5-1/2"(140 mm)

16" (406 mm)

40"(1016 mm)

48"(1219 mm)

20" (508 mm)

1386

1000

500

0

30°

60°

44

27 Cells

12 Cells

18 Cells

18 Cells

Recessed Luminaires ParabolicDeepcel 20” x 60”, 20” x 48” (DDA, DQA)Air Handling/Static Luminaire

DDA5G27LL232120SO (Data)

DDA5G12LL232120SO (Data)

DDA5G18LL232120SO (Data)

DQA5G29LS232120SO (Data)DQA 20” x 48”

RCR C. U.1 672 593 524 465 416 367 328 289 2410 21

RCR C. U.1 722 653 584 525 476 427 388 349 3110 28

RCR C. U.1 662 603 544 485 436 397 358 319 2810 25

RCR C. U.1 712 633 564 505 456 407 368 339 3010 28

DDA 20” x 60”

DDA 20” x 60”

DDA 20” x 60”

Full length air slots and one-piece faceplate create clean lines andattractive ceiling appearance. The precise fitting 3” deep louver pro-vides good glare control, while maintaining luminaire efficiency of 66.4%(12-cell, 2-T8).

Features•Only 6-1/2” deep housing.•One-piece faceplate.•Side-mounted ballast cover for cooler ballast operation.•Contoured ballast cover for maximum light efficiency.•Double-hemmed edge along louver opening eliminates light leaks

and provides maximum strength.•Full-length air slot with right angle stiffener for maximum rigidity

and no slot interference.•Heavy-gauge faceplate will not distort during transport and installation.•Also available for metric ceiling systems, consult factory.•DQA is a full width 20” x 48” Parabolic luminaire.

Options pages 150-156Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO.Magnetic Electronic PowerSpec DimmingT8: OC T8: SO T8: PS

3 LPB T8: 03For T12 lamp see page 151.LPB : Number of lamps per ballast.Drywall Kit For plaster frames, order Cat. No.: FK920X5 (20” x 60”),FK920X4 (20” x 48”).Radio Interference Filter 120, 277 or 347 volt, 50 or 60 Hz. Suffix: R.Emergency Lighting System Suffix: O (e.g. DDA5G27LL232120OCO).Emergency battery pack with charger.(90 minutes at 15% of lumens for 1 lamp).Louver Finish Low iridescence semi-specular is standard.Static For static luminaires, replace A in the basic catalogue numberby S.

Double-hemmed edge along louver opening for flat surfacewith no light leaks.

PARABOLICS

Page 38: LRG CFI

DDA5G27LL232 120 SO

DQA5G29PR232 120 SO

DDA5G12LL232 120 SO

DDA5G18LL332 120 03

45

Recessed LuminairesParabolic

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8 ' (64 sq ft/luminaire) 57 84 0.9

8' x 10' (80 sq ft/luminaire) 45 84 0.7

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 52 83 1.2

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 58 87 0.9

8' x 10' (80 sq ft/luminaire) 46 87 0.7

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 52 78 1.2

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 55 89 0.9

8' x 10' (80 sq ft/luminaire) 41 89 0.7

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 49 81 1.2

Reference Data

Efficiency 65.8%Spacing Ratio 2.0

Electronic Ballast

Input Watts (120V) 60.0WBallast Factor .88

Application Data

Luminaire Spacing FC W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 58 .9

8' x 10' (80 sq ft/luminaire) 40 .7

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 51 1.2

Basic catalogue number : Voltage : Ballast : Options :3" Deep Precision 120 See page 44 See page 44Contoured Preanodized 277Aluminum Parabolic Louver 347

Reference Data

Efficiency 66.3%Spacing Ratio 2.0

Electronic Ballast

Input Watts (120V) 60.0WBallast Factor .88

Reference Data

Efficiency 66.4%Spacing Ratio 1.4

Electronic Ballast

Input Watts (120V) 60.0WBallast Factor .88

Reference Data

Efficiency 61.1%Spacing Ratio 1.8

Electronic Ballast

Input Watts (120V) 60.0WBallast Factor .88

Type Cells Lamps Catalogueqty/type number

Air Handling 27 2-T8 DDA5G27LL23227 3-T8 DDA5G27LL332

Ordering Guide

Type Cells Lamps Catalogueqty/type number

Air Handling 12 2-T8 DDA5G12LL23212 3-T8 DDA5G12LL332

Ordering Guide

Type Cells Lamps Catalogueqty/type number

Air Handling 18 2-T8 DDA5G18LL23218 3-T8 DDA5G18LL332

Ordering Guide

Basic catalogue number : Voltage : Ballast :

Type Cells Lamps Catalogueqty/type number

Air Handling 18 2-T8 DQA5G29LS232Air Handling 18 2-T8 DQA5G29PR232

Ordering Guide

*Average Footcandles Maintained Total LLF=.82 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens.

Basic catalogue number : Voltage : Ballast : Options :

Basic catalogue number : Voltage : Ballast : Options :

Page 39: LRG CFI

1270

1000

500

0

30°

60°24" (610 mm)

36 C ll

5"(127 mm)

24"(610 mm)

24" (610 mm)

5"(127 mm)

36 Cells

24"(610 mm)

2284

1000

500

0

30°

60°

24" (610 mm)

78 Cells

5"(127 mm)

24" (610 mm)

5"(127 mm)

48"(1219 mm)

1968

1000

500

0

30°

60°

46

36 Cells

36 Cells

78 Cells

Recessed Luminaires ParabolicParabaffle 2’ x 2’ & 2’ x 4’ (MPA)1 1/2” Deep Cells • Air Handling/Static Luminaires

Parabaffle’s 3-1/2" x 3-1/2" cell size creates the illusion of greater shield-ing and smaller overall size than large cell parabolics. This luminaire isonly 5" deep, allowing it to fit in restricted plenums. It is low in bright-ness and versions are available that meet IES RP-1 recommended (basic)practice for VDT areas.

Features•3-1/2" x 3-1/2" cell (2' x 4' and 2' x 2') aluminum parabolic louver,

1-1/2" deep.•Built-in hold-down clips (2’ x 4’ & 2’ x 2’)•5" deep body. (2'x 4', 2' x 2') “T” types 5-1/4".•Captive bolt ballast mounting.•1-1/2” deep aluminum parabolic louver.

MPA2G36LS26U120SO (Data)

MPA2G36LP32U120O3 (Data)

MPA2G78LS332120O3 (Data)

Options pages 150-156Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO.Magnetic Electronic PowerSpec Dimming40W TT5: BX 40W TT5: SB 40W TT5: PBT8: OC 50W TT5: BE T8: PS

55W TT5: BF (not avail. in 347V)3 LPB 40W TT5: X3T8: SO3 LPB T8: O34 LPB T8: O4

LPB : Number of lamps per ballast. Drywall Kit For plaster frames, order Cat. No.: FK92X4 (2’ x 4’),FK92X2 (2’ x 2’).Radio Interference Filter 120, 277 or 347 volt, 50 or 60 Hz. Suffix: R.Emergency Lighting System Suffix: O (e.g. MPA2G78LS23212003O).Emergency battery pack with charger.(90 minutes at 15% of lumens for 1 lamp). For 2’ x 2’, consult CFI Fluorescent Representative.Louver Finish Low iridescence semi-specular is standard.Air Pattern Control and Air Slot Closure For horizontal and verticalair supply and to balance return air. Suffix: S. (MPA only)Static For static luminaires, replace A in the basic catalogue numberby S.

RCR C. U.1 602 543 494 445 396 357 328 289 2510 23

RCR C. U.1 602 543 494 455 406 377 338 309 2710 24

RCR C. U.1 672 603 544 495 446 407 358 329 2810 25

MPA 2’ x 2’

MPA 2’ x 2’

MPA 2’ x 4’

PARABOLICS

Page 40: LRG CFI

MPA2G36LS26U 120 SO

MPA2G36LS32U 120 03

MPA2G78LS432 120 04

47

Ordering Guide

Ordering Guide

Ordering Guide

*Meets IES RP-1 recommended (basic) for VDT applications.

Recessed LuminairesParabolic

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 48 93 0.9

8' x 10' (80 sq ft/luminaire) 39 94 0.8

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 48 80 1.2

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 29 93 0.9

RE835 lamp rated at 3000 lumens

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 70 92 1.3

8' x 10' (80 sq ft/luminaire) 58 93 1.0

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 73 80 1.8

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 46 92 1.3

RE835 lamp rated at 2900 lumens

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 80 95 1.3

8' x 10' (80 sq ft/luminaire) 66 96 1.1

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 80 83 1.8

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 46 97 1.3

RE835 lamp rated at 3000 lumens

Basic catalogue number : Voltage : Ballast : Options :Parabaffle 120 See page 46 See page 46Recessed 277 Add appropriateParabolic 347 suffix to catalogue

number

Basic catalogue number : Voltage : Ballast : Options :

Basic catalogue number : Voltage : Ballast : Options :

Reference Data

Efficiency 58.2%Spacing Ratio 1.1

Electronic Ballast

Input Watts (120V) 60.0WBallast Factor .88

Reference Data

Efficiency 54.8%Spacing Ratio 1.4

Electronic Ballast

Input Watts (120V) 83.0WBallast Factor .92

Reference Data

Efficiency 62.6%Spacing Ratio 1.6

Electronic Ballast

Input Watts (120V) 85.0WBallast Factor .88

Type Luminaire Cells Lamps Exposed Exposed Slot-T orsize qty/type T-Grid Concealed T-Grid

Air 2 x 2 36 2-T8U6 MPA2G36LS26U MPA2T36LS26UHandling

Type Luminaire Cells Lamps Exposed Exposed Slot-T orsize qty/type T-Grid Concealed T-Grid

Air 2 x 2 36 3-T8U1.6 MPA2G36LS32U MPA2T36LS32UHandling 2 x 2 36 3-TT5 MPA2G36LS3FT MPA2T36LS3FT

Type Luminaire Cells Lamps Exposed Exposed Slot-T orsize qty/type T-Grid Concealed T-Grid

Air 2 x 4 78 3-T8 MPA2G78LS332 MPA2T78LS332Handling 2 x 4* 78 3-T8 MPA2G78PP332 MPA2T78PP332

2 x 4 78 4-T8 MPA2G78LS432 MPA2T78LS432

*Average Footcandles Maintained Total LLF=.82 Reflectance: 80% Ceiling, 50% Wall, 20% Floor.

Page 41: LRG CFI

1681

1000

500

0

30°

60°

12" (305 mm)

4-3/4"(121 mm)

24" (610 mm)

5"(127 mm)

1464

0°i

1000

500

0

30°

60°

24" (610 mm)

5"(127 mm)

2465

2000

1000

0

30°

60°

24" (610 mm)

5"(127 mm)

24" (610 mm)

5"(127 mm)

24" (610 mm)

5"(127 mm)

3685

2000

1000

0

30°

60°

48

Recessed Luminaires Lens and AsymmetricPrismalyte Plus 1’x 4’, 2’x 2’, 2’x 4’ (PRA)Premium Specification Grade Lens • Air Handling/Static Luminaires

Features•5" deep. (2' x 4') (2' x 2').•2-31/32” lamp to lens for better lamp obscuration (2’ x 2’, 2’ x 4’).•4-3/4" deep. (1' x 4' model for exposed slot-T or consealted T-grid)•One-piece housing is embossed construction for added strength.•Efficiency 76.7%, 4 light.•Black housing exterior for cooler ballast operating temperature.•Turned-up edges for safe handling.•Built-in hold-down clips (2'x2'/2'x4').•Perfectly uniform four side reveal with black finish for floating effect.•Door jamb finished black on four sides for positive light stop.•Spring-loaded latches.

PRA1GRFVA232120SO (Data)

PRA2GRFVA26U120SO (Data)

PRA2GRFVA32U120O3 (Data)

Options pages 150-156Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO.Magnetic Electronic PowerSpec Dimming40W TT5: BX 40W TT5: SB 40WTT5: PBT8: OC 50W TT5: BE T8: PS

55W TT5: BF (not avail. in 347V)3 LPB 40W TT5: X31 or 2 LPB T8: SO3 LPB T8: O34 LPB T8: O4

For T12 lamp see page 151.LPB : Number of lamps per ballast.Drywall Kit For plaster frames, order Cat. No.: FK92X4 (2’ x 4’),FK92X2 (2’ x 2’), FK91X4 (1’ x 4’).Internal Fusing Consult your CFI Fluorescent representative.Radio Interference Filter 120, 277 or 347 volt, 50 or 60Hz. Suffix: R.Emergency Lighting System Suffix: O (e.g. PRA1GRFVA232120SOO).Emergency battery pack with charger.(90 minutes at 15% of lumens for 1 lamp).For 2’ x 2’ consult CFI Fluorescent Representative.Special Lens - VA lens pattern 12 prismatic virgin acrylic is standard.For other available lenses, see page 155.Air Pattern Control and Air Slot Closure For horizontal and verticalsupply and to balance return air. Suffix: S.Static For static luminaires, replace PRA in the basic cataloguenumber by PRS.

Prismalyte Plus luminaires are top of the line air handling lensedfluorescent luminaires with floating door appearance, regressedaluminum doors and black painted housing for optimum lamp andballast operation. Luminaires are a full 5" deep for minimal lamp imagedemanded in a high specification troffer.

PRA2GRFVA432120O4 (Data)

RCR C. U.1 682 613 554 495 446 407 368 329 2910 27

RCR C. U.1 642 573 514 465 426 387 348 319 2810 25

RCR C. U.1 662 593 534 475 436 397 368 339 3010 28

RCR C. U.1 812 713 634 575 516 467 428 399 3610 33

PRA 1’ x 4’

PRA 2’ x 2’

PRA 2’ x 2’

PRA 2’ x 4’L

ENSRECESSED

Page 42: LRG CFI

PRA1GRFVA232 120 OC

PRA2GRFVA26U 120 SO

PRA2GRFVA32U 120 03

PRA2GRFVA432 120 04

49

Recessed LuminairesLens

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 50 59 0.9

8' x 10' (80 sq ft/luminaire) 41 59 0.8

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 49 84 1.2

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 30 59 0.9

RE835 lamp rated at 3000 lumens

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 47 66 0.9

8' x 10' (80 sq ft/luminaire) 39 66 0.8

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 46 85 1.2

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 29 66 0.9

RE835 lamp rated at 3000 lumens

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 70 57 1.3

8' x 10' (80 sq ft/luminaire) 59 58 1.0

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 71 78 1.8

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 46 57 1.3

RE835 lamp rated at 2900 lumens

Type Luminaire Lamps Exposedsize qty/type T-Grid

Air 1 x 4 1-T8 PRA1GRFVA132Handling 1 x 4 2-T8 PRA1GRFVA232

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :Floating Lens Frame 120 See page 48 See page 48Recessed Fluorescent 277 Add appropriateTroffer 347 suffix to catalogue

number

Basic catalogue number : Voltage : Ballast : Options :

Basic catalogue number : Voltage : Ballast : Options :

Reference Data

Efficiency 63.7%Spacing Ratio 1.3

Electronic Ballast

Input Watts (120V) 60.0WBallast Factor .88

Reference Data

Efficiency 59.8%Spacing Ratio 1.4

Electronic Ballast

Input Watts (120V) 60.0WBallast Factor .88

Reference Data

Efficiency 62.2%Spacing Ratio 1.3

Electronic Ballast

Input Watts (120V) 83.0WBallast Factor .92

Reference Data

Efficiency 76.7%Spacing Ratio 1.3

Electronic Ballast

Input Watts (120V) 112.0WBallast Factor .88

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 118 64 1.8

8' x 10' (80 sq ft/luminaire) 98 64 1.4

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 117 81 2.3

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 70 64 1.8

RE835 lamp rated at 3000 lumens

Basic catalogue number : Voltage : Ballast : Options :

Type Luminaire Lamps Exposed Exposed Slot-T orsize qty/type T-Grid Concealed T-Grid

Air 2 x 2 2-T8U6 PRA2GRFVA26U PRA2TRFVA26UHandling

Ordering Guide

Type Luminaire Lamps Exposed Exposed Slot-T orsize qty/type T-Grid Concealed T-Grid

Air 2 x 2 3-T8U1.6 PRA2GRFVA32U PRA2TRFVA32UHandling 2 x 2 3-TT5 PRA2GRFVA3FT PRA2TRFVA3FT

Ordering Guide

Type Luminaire Lamps Exposed Exposed Slot-T orsize qty/type T-Grid Concealed T-Grid

Air 2 x 4 2-T8 PRA2GRFVA232 PRA2TRFVA232Handling 2 x 4 3-T8 PRA2GRFVA332 PRA2TRFVA332

2 x 4 4-T8 PRA2GRFVA432 PRA2TRFVA432

Ordering Guide

*Average Footcandles Maintained Total LLF=.75 Reflectance: 80% Ceiling, 50% Wall, 20% Floor.

Page 43: LRG CFI

1681

1000

500

0

30°

60°

12" (305 mm)

4-3/4"(121 mm)

24" (610 mm)

5"(127 mm)

1567

1000

500

0

30°

60°

24" (610 mm)

5"(127 mm)

2125

1000

500

0

30°

60°

24" (610 mm)

5"(127 mm)

24" (610 mm)

5"(127 mm)

24" (610 mm)

5"(127 mm)

3690

2000

1000

0

30°

60°

50

FS RA

Recessed Luminaires Lens and AsymmetricSpecPlus 1’x 4’, 2’x 2’, 2’x 4’ (SPS)Premium Specification Grade Lens • Static Fluorescent Luminaires

SpecPlus offers higher quality and more features than any other specifi-cation grade troffer. Full 5" deep body, built-in clips with positive clamping by screws, easy re-lamping, and an extraordinary 1000 sq. inchlens area puts this luminaire in the lead on performance, safety and easeof maintenance.

Features•Full 5" deep (2’ x 2’ and 2’ x 4’).•2-31/32" lamp to lens for better lamp obscuration.•Efficiency 81.2%, (4 light).•Built-in hold-down clips (2’ x 2’ / 2’ x 4’).•One-piece housing is embossed for added strength.•Smoothly-turned edges for safe handling.•Captive bolt ballast mounting.•Reversible slim-line lens frames with 1,000 square inch lens

area (2’ x 4’).•Door jamb with integral positive light stop.•Mitered lens frames, flange and trim.•Cam-action latches.

SPS1GFSVA232120SO (Data)

SPS2GFSVA26U120SO (Data)

SPS2GFSVA32U120O3 (Data)

SPS2GFSVA432120O4 (Data)

Options pages 150-156Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO.Magnetic Electronic PowerSpec Dimming40W TT5: BX 40W TT5: SB 40W TT5: PBT8: OC 50W TT5: BE T8: PS

55W TT5: BF (not avail. in 347V)3 LPB 40W TT5: X31 or 2 LPB T8: SO3 LPB T8: O34 LPB T8: O4

For T12 lamp see page 151.LPB : Number of lamps per ballast.Drywall Kit For plaster frames, order Cat. No.: FK92X4 (2’ x 4’),FK92X2 (2’ x 2’), FK91X4 (1’ x 4’).Internal Fusing Consult your CFI Fluorescent representative.Radio Interference Filter 120, 277 or 347 volt, 50 or 60Hz. Suffix: R.Emergency Lighting System Suffix: O (e.g. SPS1GFSVA232120SOO).Emergency battery pack with charger.(90 minutes at 15% of lumens for 1 lamp).Special Lens - VA lens pattern 12 prismatic virgin acrylic is standard.For other available lenses, see page 155.Door Option - FS Flat steel door is standard. For regressed aluminumdoor frame, replace FS by RA. For flush aluminum door frame, replaceFS by FA.

RCR C. U.1 692 623 554 505 456 417 378 339 3010 27

RCR C. U.1 742 653 584 525 476 427 388 359 3210 30

RCR C. U.1 622 563 514 465 426 387 358 359 2910 27

RCR C. U.1 852 753 674 605 546 497 448 409 3710 34

SPS 1’ x 4’

SPS 2’ x 2’

SPS 2’ x 2’

SPS 2’ x 4’L

ENSRECESSED

SPS, AA, AAS and ELS fixtures all have thesedoor frame options.

Flush Steel (Standard) Regressed Aluminum

Page 44: LRG CFI

SPS1GFSVA232 120 SO

SPS2GFSVA26U 120 SO

SPS2GFSVA32U 120 03

SPS2GFSVA432 120 04

51

Recessed LuminairesLens

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 50 57 0.9

8' x 10' (80 sq ft/luminaire) 42 57 0.8

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 50 85 1.2

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 31 57 0.9

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 53 56 0.85

8' x 10' (80 sq ft/luminaire) 44 56 0.68

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 51 80 1.1

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 33 56 0.85

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 67 52 1.3

8' x 10' (80 sq ft/luminaire) 54 53 1.0

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 64 77 1.8

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 41 52 1.3

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 125 60 1.8

8' x 10' (80 sq ft/luminaire) 103 60 1.4

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 114 81 2.3

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 74 96 1.8

Type Luminaire Lamps Exposedsize qty/type T-Grid

Static 1 x 4 1-T8 SPS1GFSVA1321 x 4 2-T8 SPS1GFSVA232

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :Lens Frame 120 See page 50 See page 50Recessed Fluorescent 277 Add appropriateTroffer 347 suffix to catalogue

number

Basic catalogue number : Voltage : Ballast : Options :

Basic catalogue number : Voltage : Ballast : Options :

Basic catalogue number : Voltage : Ballast : Options :

Reference Data

Efficiency 64.6%Spacing Ratio 1.3

Electronic Ballast

Input Watts (120V) 62.0WBallast Factor .88

Reference Data

Efficiency 70.5%Spacing Ratio 1.3

Electronic Ballast

Input Watts (120V) 60.0WBallast Factor .88

Reference Data

Efficiency 57.9%Spacing Ratio 1.2

Electronic Ballast

Input Watts (120V) 83.0WBallast Factor .88

Reference Data

Efficiency 81.2%Spacing Ratio 1.3

Electronic Ballast

Input Watts (120V) 112.0WBallast Factor .88

Type Luminaire Lamps Exposedsize qty/type T-Grid

Static 2 x 2 2-T8U6 SPS2GFSVA26U

Ordering Guide

Type Luminaire Lamps Exposedsize qty/type T-Grid

Static 2 x 2 3-T8U1.6 SPS2GFSVA32U2 x 2 3-TT5 SPS2GFSVA3FT

Ordering Guide

Type Luminaire Lamps Exposedsize qty/type T-Grid

Static 2 x 4 2-T8 SPS2GFSVA2322 x 4 3-T8 SPS2GFSVA3322 x 4 4-T8 SPS2GFSVA432

Ordering Guide

*Average Footcandles Maintained Total LLF=.75 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens.

Page 45: LRG CFI

1674

1100

550

0

30°

60°

4"(102mm)

48"(1220mm)

24" (610mm)

1797

1000

500

0

30°

60°

4"(102mm)

24" (610mm)

2626

2000

1000

0

30°

60°4"

(102mm)

48"(1220mm)

24" (610mm)

52

or

Recessed Luminaires LensSpecTroffer 1’x 4’, 2’x 4’ (SQS)Specification Grade Shallow Design Troffer • Static Luminaires

MR4WS232120SO (Data)

SQS2GFSVA232120SO (Data)SQS 2’ x 4’

SQS2GFSVA332120O3 (Data)SQS 2’ x 4’

Options pages 150-156Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO.Magnetic Electronic PowerSpec DimmingT8: OC T8: SO T8: PS

3 LPB T8: O3 (not avail. in 347V)4 LPB T8: O4

For T12 lamp see page 151.LPB : Number of lamps per ballast.Drywall Kit For plaster frames, order Cat. No.: FK92X4 (2’ x 4’).Internal Fusing Consult your CFI Fluorescent representative.Radio Interference Filter 120, 277 or 347 volt, 50 or 60Hz. Suffix: R.Emergency Lighting System Suffix: O (e.g. SQS2GFSVA232120SOO).Emergency battery pack with charger. (90 minutes at 15% of lumens for 1 lamp).Special Lens - VA lens pattern 12 prismatic virgin acrylic is standard.For other available lenses, see page 155.

RCR C. U.1 902 783 684 605 546 487 438 409 3610 33

RCR C. U.1 792 703 624 565 506 457 418 389 3510 32

RCR C. U.1 772 693 624 565 506 457 418 379 3310 30

Features• Continuous trough appearance without interruption of ceiling cross tees.•Post painted baked white acrylic enamel reflector finish for better

non-yellowing properties vs. other paints.•Hangers lock ceiling system together.•Uninterrupted wiring trough when mounted in continuous rows.• Spring-loaded lampholders.•Luminaire supports ceiling tile at end of row.•Non continuous trough available.•Optional silver reflector.

Options pages 150-156Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO.Magnetic Electronic PowerSpec DimmingT8: OC T8: SO T8: PST12: LE† 4 LPB T8: O4 (not avail. in 347V)LPB : Number of lamps per ballast.Electrical/Wiring Options For special wiring, fusing, consult factory.Internal Fusing Consult your CFI Fluorescent representative.Radio Interference Filter 120, 277 or 347 volt, 50 or 60Hz. Suffix: R.Emergency Lighting System Suffix: O (e.g. MRWS232120SOO).Emergency battery pack with charger. (90 minutes at 15% of lumens for 1 lamp).

MR

Merchandizer 1’x 4’, 1’x 8’ (MR) Recessed Open Reflector

LENSR

ECESSED

• T12 options are limited due to new regulations.Please consult factory for their availability.

• Please refer to page 13 for more information regarding the availability of T12and the New Energy Efficient regulations set forth by National Resources Canada.

Page 46: LRG CFI

MR4WS232 120 SO

SQS2GFSVA232 120 SO

SQS2GFSVA432 120 04

53

Recessed LuminairesLens and Open

Reference Data

Efficiency 91.9%Spacing Ratio 1.4

Electronic Ballast

Input Watts (120V) 62.0WBallast Factor .88

Application Data*

Luminaire Spacing FC W/Sq Ft

50' x 70' x 12' Space

12' on centre 84 1.2

50' x 70' x 12' Space

16' on centre 74 1.0

50' x 70' x 8.5' Space

12' on centre 96 1.3

30' x 30' x 8.5' Space

12' on centre 95 1.5

Reference Data

Efficiency 74.7%Spacing Ratio 1.4

Electronic Ballast

Input Watts (120V) 62.0WBallast Factor .88

Application Data*

Luminaire Spacing FC W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 55 0.8

8' x 10' (80 sq ft/luminaire) 45 0.7

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 62 1.2

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 35 0.8

Reference Data

Efficiency 72.2%Spacing Ratio 1.4

Electronic Ballast

Input Watts (120V) 85.0WBallast Factor .90

Application Data*

Luminaire Spacing FC W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 81 1.2

8' x 10' (80 sq ft/luminaire) 66 1.0

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 89 1.9

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 47 1.2

Type Luminaire Luminaire Lamps Cataloguewidth length qty /type number

Recess 12” 48” 1-T8 MR4WS132Static 12” 48” 2-T8 MR4WS232

12” 48” 3-T8 MR4WS33212” 96” 4-T8 (tandem) MR8WS23212” 96” 6-T8 MR8WS332

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :MR series 120 See page 52 See page 522-T8 32W 277 Add appropriate

347 suffix to cataloguenumber

Type Luminaire Lamps Exposedsize qty/type T-Grid

Static 1 x 4 1-T8 SQS1GFSVA1321 x 4 2-T8 SQS1GFSVA232

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :Spec Troffer 120 See page 52 See page 52Luminaire 277 add appropriate

347 suffix to cataloguenumber

Type Luminaire Lamps Exposedsize qty/type T-Grid

Static 2 x 4 2-T8 SQS2GFSVA2322 x 4 3-T8 SQS2GFSVA3322 x 4 4-T8 SQS2GFSVA432

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :

When ordering for row mounting replace middle unit S by M.When ordering silver reflector change W by S.

Page 47: LRG CFI

48

1929

1000

500

0

30°

60°

4"(102 mm)

24" (610 mm)

24" (610 mm)

1500

1000

500

0

30°

60°

48"1219 mm)

24" (610 mm)

3-5/8"(92 mm)

2758

2000

1000

0

30°

60°

3-5/8"(92 mm)

48"(1219 mm)

24" (610 mm)

3337

2000

1000

0

30°

60°

AA 4 120 SO VA

54

Recessed Luminaires LensAA Troffer 1’ x 4’, 2’ x 2’ & 2’ x 4’High Performance Lens Troffer • Static Luminaires

CFI’s high performance AA series of lens troffers offers unique featuresthat outperform and extend more value for money than any othercomparable fluorescent troffer. The 2’ x 4’ and 1’ x 4’ models offer rolledover edges, integrated light leak stops, mitered corners on door framesto make this the toughest and highest performance troffer in its class.Side mount ballast on 1’ x 4’ ideal for 1 lamp applications.

Features•73.3% efficient (4 lamp T8), 80.9% (3 lamp T8), 78.6% (2 lamp T8).•3-5/8" deep (2' x 4').•All other types 4" deep.•2' x 4' luminaire side rails have rolled-over edges for maximum

safety.•Flush steel full-sized door frame with mitered corner detailing.

(1' x 4', 2' x 4')•Angle regressed extruded aluminum door (optional).•Built-in Hold-Down clip. (2' x 2', 2' x 4')

AA248-120SOVA (Data)

AA2U6-120SOVA (Data)

AA348-120O3VA (Data)

AA448-120O4VA (Data)

Options pages 150-156Drywall Kit For plaster frames, order Cat. No.: FK92X4 for (2' x 4')troffer; FK92X2 for (2' x 2') troffer; FK91X4 for (1' x 4') troffer.Internal Fusing Consult your CFI Fluorescent representative.Radio Interference Filter 120, 277 or 347 volt, 50 or 60Hz. Suffix: R.Emergency Lighting System Suffix: O (e.g. AA248-120SOVAO).Emergency battery pack with charger.(90 minutes at 15% of lumens for 1 lamp).Special Lens - VA lens pattern 12 prismatic virgin acrylic is standard.For other available lenses, see page 155.

FamilyAATheTroffer

BallastdesignationLE = T12 MagneticOC = T8 MagneticSO = T8 ElectronicO3 = T8 Electronic

(one 3-lamp)O4 = T8 Electronic

(one 4-lamp)

Shielding designationVA = 0.095”

Pattern 12Acrylic Lens

For complete shieldingoption listing, refer to page155. CFI has standardizedthe suffix designation for alltypes of Troffers and Trofferoptions.

LampQuantity1 = 1 Lamp2 = 2 Lamp3 = 3 Lamp4 = 4 Lamp

Nominal LampSize24 = 24”48 = 48”U2 = 6” U Lamp T12U6 = 6” U Lamp T8W8 = 2 Lamps 48” 2x4

Voltage120 = 120V277 = 277V347 = 347V

Door FrameBlank= Flush steelRA = Regressed

aluminum

Special OptionsFor complete optionlisting, refer to pages150-156.

Hemmed edge 2’ x 4’ and1’ x 4’ for safe handling.

End cap hold-down clip.(2' x 2', 2' x 4')

RCR C. U.1 752 673 604 545 496 447 408 379 3410 32

RCR C. U.1 732 653 584 525 476 427 388 359 3210 30

RCR C. U.1 812 713 634 565 516 467 428 389 3510 32

RCR C. U.1 772 683 604 545 486 447 408 369 3410 31

AA 1’ x 4’

AA 2’ x 2’

AA 2’ x 4’

AA 2’ x 4’

AA series catalogue numbering system

Examples of catalogue number:AA448-120O4VA = AA Troffer, 4 lamp, T8 Electronic, 0.095” Pattern

12 lens, flush steel door frame

LENSR

ECESSED

• T12 options are limited due to new regulations.Please consult factory for their availability.

• Please refer to page 13 for more information regarding the availability of T12 and the New Energy Efficient regulations set forthby National Resources Canada.

Page 48: LRG CFI

AA 2 48 120 SO VA

AA 2 U6 120 SO VA

AA 3 48 120 o3 VA

AA 2 W8 120 SO VA

55

Type Luminaire Lamps Exposedsize qty/type T-Grid

AAFlush Steel Static 2 x 4 2-T8/T12 AA2W8†Door Frame Static 2 x 4 4-T8/T12 AA448

Ordering Guide

† Efficiency of 78.6% with (2) T8 lamps. 82.7% efficiency with AAS2G luminaire, see pages 56-57.

Ordering Guide

Ordering Guide

Ballastdesignation

Shieldingdesignation

Voltage DoorFrame

SpecialOptions

Basic Catalogue Number Ballastdesignation

Shieldingdesignation

Voltage DoorFrame

SpecialOptions

Basic Catalogue Number Ballastdesignation

Shieldingdesignation

Voltage DoorFrame

SpecialOptions

Recessed LuminairesLens

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 52 59 .9

8' x 10' (80 sq ft/luminaire) 42 59 .8

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 45 84 1.3

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 48 58 0.9

8' x 10' (80 sq ft/luminaire) 40 58 0.8

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 47 81 1.2

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 30 58 0.9

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 94 61 1.3

8' x 10' (80 sq ft/luminaire) 78 61 1.1

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 90 81 1.8

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 54 97 1.3

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 113 58 1.8

8' x 10' (80 sq ft/luminaire) 94 59 1.4

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 111 80 2.3

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 68 96 1.8

Type Luminaire Lamps Exposedsize qty/type T-Grid

AAFlush Steel Static 1 x 4 1-T8/T12 AA148Door Frame 1 x 4 2-T8/T12 AA248

Ordering Guide

Type Luminaire Lamps Exposedsize qty/type T-Grid

AAFlush Steel Static 2 x 2 2-T8/T12 AA224Door Frame Static 2 x 2 2-T8U6 AA2U6

Static 2 x 2 2-T12U6 AA2U2

Type Luminaire Lamps Exposedsize qty/type T-Grid

AAFlush Steel Static 2 x 4 3-T8/T12 AA348Door Frame

Reference Data

Efficiency 70.7%Spacing Ratio 1.3

Electronic Ballast

Input Watts (120V) 60.0WBallast Factor .88

Reference Data

Efficiency 69.5%Spacing Ratio 1.3

Electronic Ballast

Input Watts (120V) 60.0WBallast Factor .88

Reference Data

Efficiency 80.9%Spacing Ratio 1.3

Electronic Ballast

Input Watts (120V) 85.0WBallast Factor .88

Reference Data

Efficiency 73.3%Spacing Ratio 1.4

Electronic Ballast

Input Watts (120V) 112.0WBallast Factor .88

*Average Footcandles Maintained Total LLF=.75 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens.

Basic Catalogue NumberAA Troffer

Basic Catalogue Number Ballastdesignation

Shieldingdesignation

Voltage DoorFrame

SpecialOptions

Page 49: LRG CFI

2390

1500

750

0

30°

60°

24" (609.6 mm)

3-5/8"(92.1 mm)

24" (609.6 mm)

3-5/8"(92.1 mm)

48"(1219 mm)

1128

600

200

0

30°

60°

24" (609.6 mm)

3-5/8"(92.1 mm)

1943

1000

500

0

30°

60°

48"(1219 mm)

56

FS* RA*

SPECULAR SILVERREFLECTOR

RCR C. U.1 872 783 694 625 566 507 458 419 3710 33

ELS2GFSVA232120SO (Data)

ELS1GFSVA132120OC (Data)

AAS2GFSVA232120SO (Data)

ELS 2’ x 4’

ELS 1’ x 4’

AAS 2’ x 4’

RCR C. U.1 922 833 744 675 606 557 498 459 4010 37

RCR C. U.1 862 773 694 625 566 517 468 429 3810 34

Recessed Luminaires LensSilverescent 1’x 4’, 2’x 2’, 2’x 4’ (ELS) • High Efficiency White Paint 1’x 4’, 2’x 2’, 2’x 4’ (AAS)Energy Saving Lens Troffer • Static Luminaires

Silverescent luminaires (ELS) are designed to conserve energy. The widedistribution and the 95% reflective silver laminate specular reflector inthe 2 x 4, 2 lamp luminaire, provides the same lighting level as a 10 yearold 2 x 4, 4 lamp luminaire with as little as 30% of the energy consump-tion. The high efficiency white paint (AAS) is a cost-effective way to saveenergy compared to specular reflector luminaires.

Features•95% reflective silver laminate specular reflector protected with

strippable film (ELS).•86.2% efficient (2' x 4' T8) (ELS - Silverescent).•One-piece housing is embossed for added strength.•End cap has single form configuration and formed edges for easy

lamping and safety.•Turned up edges for safe handling (2' x 4').•Lens frame overlaps end cap for positive light stop.•Reversible slim-line lens frames with 1,000 square inch lens area (2' x 4').•Mitered appearance lens frames.•Angle regressed extruded aluminum door (RA optional).•Cam-action latches.•92% reflective white paint on AAS.•Built-in Hold-Down clip (2’ x 4’).

Options pages 150-156Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO.Magnetic Electronic PowerSpec DimmingT8: OC T8: SO T8: PS

3 LPB T8: O3 (not avail. in 347V)4 LPB T8: O4

For T12 lamp see page 151.LPB : Number of lamps per ballast.Drywall Kit For plaster frames, order Cat. No.: FK92X4 (2’ x 4’),FK91X4 (1’ x 4’), FK92X2 (2’ x 2’),Internal Fusing Consult your CFI Fluorescent representative.Radio Interference Filter 120, 277 or 347 volt, 50 or 60Hz. Suffix: R.Emergency Lighting System Suffix: O (e.g. ELS2GFSVA232120SOO).(N/A 2’ x 2’)Emergency battery pack with charger.(90 minutes at 15% of lumens for 1 lamp).Special Lens - VA lens pattern 12 prismatic virgin acrylic is standard.For other available lenses, see page 156.

Flush SteelDoor Frame

STANDARD OPTION

Regressed AluminumDoor Frame

*Note: Replace FS by RA in the number for regressed aluminum door frame.

LENSR

ECESSEDSPS, SQS, AA, AAS and ELS fixtures all have these door frame options.

Page 50: LRG CFI

ELS2GFSVA232 120 SO

ELS1GFSVA232 120 SO

AAS2GFSVA232 120 SO

57

Recessed LuminairesLens

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 66 69 0.9

8' x 10' (80 sq ft/luminaire) 52 69 0.8

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 59 87 1.2

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 39 98 0.9

RE835 lamp rated at 3000 lumens

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8’ on centre 34 59 1.0

10’ on centre 28 59 0.8

12' x 16' x 8.5' Space

6' on centre 36 84 1.3

RE835 lamp rated at 2900 lumens

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 64 69 0.9

8' x 10' (80 sq ft/luminaire) 51 69 0.8

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 57 87 1.2

RE835 lamp rated at 3000 lumens

Type Luminaire Lamps Exposedsize qty/type T-Grid

Flush Steel Static 2 x 2 2-T8U6 ELS2GFSVA26UDoor Frame 2 x 4 2-T8 ELS2GFSVA232

3-T8 ELS2GFSVA3324-T8 ELS2GFSVA432

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :3 1/2" Deep 120 See page 56 See page 56Troffer - 95% Reflective 277 Add appropriateSilver Insert 347 suffix to catalogue

number

Type Luminaire Lamps Exposedsize qty/type T-Grid

Flush Steel Static 1 x 4 1-T8 ELS1GFSVA132Door Frame 2-T8 ELS1GFSVA232

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :

Type Luminaire Lamps Exposedsize qty/type T-Grid

Flush Steel Static 1 x 4 1-T8 AAS1GFSVA132Door Frame 1 x 4 2-T8 AAS1GFSVA232

2 x 2 2-T8U6 AAS2GFSVA26U2 x 4 2-T8 AAS2GFSVA2322 x 4 3-T8 AAS2GFSVA332

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :

Reference Data

Efficiency 86.2%Spacing Ratio 1.2

Electronic Ballast

Input Watts (120V) 62.0WBallast Factor .88

Reference Data

Efficiency 80%Spacing Ratio 1.3

Electronic Ballast

Input Watts (120V) 31.0WBallast Factor .88

Reference Data

Efficiency 82.7%Spacing Ratio 1.4

Electronic Ballast

Input Watts (120V) 62.0WBallast Factor .88

*Average Footcandles Maintained Total LLF=.75 Reflectance: 80% Ceiling, 50% Wall, 20% Floor

Page 51: LRG CFI

1821

1000

500

0

30°

60°

5"127 mm)

40"1016 mm)

60"(1524 mm)

20" (508 mm)

15-5/8" (397 mm)

5"127 mm)

40"1016 mm)

48"1219 mm)

20" (508 mm)

15-5/8" (397 mm)

1821

1000

500

0

30°

60°

58

20” x 60”

20” x 48”

Recessed Luminaires LensTroffer (imperial or metric) 20”x 60”, 500 x 1500Air Supply / Return or Static

Features•Only 5” deep.•Faceplate made with die formed 20 gauge cold rolled steel with

edges hemmed for rigidity.•Easily removable ballast cover.•Twin knockout access plate.•Luminaire efficiency 73.2%.•Lay in lens standard (see drawing LI on page 155).•Regressed and flush aluminium door frames available. Replace LI

with SA, RA, FA.

DSA5GLIVA232120SO (Data)DSA 20” x 60”

Options pages 150-156Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO.Magnetic Electronic PowerSpec Dimming

T8:SO T8:PST8:OC 3 LPB T8:O3 (not avail. in 347V)For T12 lamp see page 151.LPB : Number of lamps per ballast. Drywall Kit For plaster frames, order Cat. No.: FK9204 (20” x 48”),FK9205 (20” x 60”).Internal Fusing Consult your CFI Fluorescent representative.Radio Interference Filter 120, 277 or 347 volt, 50 or 60Hz. Suffix: R.Emergency Lighting System Suffix: O (e.g. DSA5GLIVA232120SOO).Emergency battery pack with charger. (90 minutes at 15% of lumens for 1 lamp).Special Lens - VA lens pattern 12 prismatic virgin acrylic is standard.For other available lenses, see page 155.Static For static luminaires, replace DSA, DMA, DTA or DLA in thebasic catalogue number by DSS, DMS, DTS or DLS.Filler Plate For 20” x 60” opening with 20” x 48” luminaire, orderFP9205.

Double-hemmed edge along louver opening for flat surface with no light leaks.

DTA5GLIVA232120SO (Data)DTA 20” x 48”

RCR C. U.1 772 683 614 545 496 447 408 379 3410 32

RCR C. U.1 772 683 614 545 496 447 408 379 3410 32

LENSR

ECESSED

Page 52: LRG CFI

DSA5GLIVA232 120 SO

DTA5GLIVA232 120 SO

59

LENS

Faceplate ViewRegressed Aluminum Door (RA)

Faceplate ViewFlush Steel Door (FA)

Faceplate ViewLay in Aluminum Frame (SA)

Faceplate ViewStandard Lay in Lens (LI)

FACEPLATE

FACEPLATE

DOORFRAME

FACEPLATE

DOORFRAME

LENS

FACEPLATEDOORFRAME

LENS

LENS

*Average Footcandles Maintained Total LLF=BF (.90) x .85 = .74 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens.

Recessed LuminairesLens

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 54 64 1.3

8' x 10' (80 sq ft/luminaire) 44 64 1.0

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 50 81 1.7

Type Luminaire Lamps Cataloguesize qty/type number

Air Handling 20” x 60” 2-T8 DSA5GLIVA23220” x 60” 3-T8 DSA5GLIVA332500mm x 1500mm 2-T8 DMA5GLIVA232500mm x 1500mm 3-T8 DMA5GLIVA332

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :Troffer 20” x 60” 120 See page 58. See page 58

277 add appropriate347 suffix to catalogue

number

Reference Data

Efficiency 73.2%Spacing Ratio 1.4

Electronic Ballast

Input Watts (120V) 60.0WBallast Factor .88

Not for continuous row mounting.

SAStandard Lift & ShiftAluminum Frame.Replace LI by SA.

LI

Note: Subsitute LI for:

RARegressed AluminumLift & Shift Frame.Replace LI by RA.

FAFlush Aluminum Lift &Shift Frame.Replace LI by FA.

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 54 64 1.3

8' x 10' (80 sq ft/luminaire) 44 64 1.0

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 50 81 1.7

Type Luminaire Lamps Cataloguesize qty/type number

Air Handling 20” x 48” 2-T8 DTA5GLIVA23220” x 48” 3-T8 DTA5GLIVA332500mm x 1200mm 2-T8 DLA5GLIVA232500mm x 1200mm 3-T8 DLA5GLIVA332

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :

Reference Data

Efficiency 73.2%Spacing Ratio 1.4

Electronic Ballast

Input Watts (120V) 60.0WBallast Factor .88

Not for continuous row mounting.

Page 53: LRG CFI

1500

1000

500

0

30°

60°

7-13-16"(183 mm)Opening

4-7/16"(113 mm)

10-13/16" (275 mm)

7-13-16"(183 mm)Opening

4-7/16"(113 mm)

10-13/16" (275 mm)

24" (610 mm)

7-13-16"(183 mm)Opening

4-7/16"(113 mm)

10-13/16" (275 mm)

7-13-16"(183 mm)Opening

4-7/16"(113 mm)

10-13/16" (275 mm)

48" (1219 mm)

3000

2000

1000

0

30°

60°

60

Opening

Opening

Opening

Opening

Recessed Wallwasher LuminairesWal-Lyter 2’, 4’Wall Washer / Accent Light • High Performance / Specular Optic

Wal-Lyter is a high performance wall-washer that delivers the highestlight levels and an exceptionally even wash of light from the ceiling lineto the floor line utilizing TT5 compact fluorescent lamps. It is much moreefficient and more cost effective than most incandescent units producingequivalent illumination. Wal-Lyter is ideal for highlighting merchandisedisplays, brightening the walls in offices illuminated with sharp cut-offparabolics and for many other wall lighting applications. Lamp is neverin view for normal wall wash applications.

Features•Low iridescent specular reflector system for precise controlled light

output.•Evenly lights vertical surfaces or displays.•87% energy savings vs. incandescent.•3150 lumen (40 watt) TT5 type lamp requires fewer luminaires to pro-

vide the same wall illumination as a 60 watt incandescent wallwash-er.

•20,000 hours TT5 lamp life requires less maintenance than incandes-cent wallwasher.

•Fits all lay-in grid ceiling systems.•One-piece body and integral hanger for easy, quick installation.•WLRK lens, extruded acrylic prismatic lens to hide lamp from direct

view when looking into the luminaire.

WLRN124120BX (Data)

WLRN244120BX (Data)

Options pages 150-156Ballast Specify voltage (120, 277 or 347) and add uffix, e.g. 120SO.Magnetic Electronic PowerSpec Dimming40W TT5: BX 40W TT5: SB 40W TT5: PB

50W TT5: BE 50W, 55W TT5: PC55W TT5: BF (not avail. in 347V)

T8 and T12 not available*.Drywall Kit For plaster frames, order Cat. No.: WL2DF (2’ luminaires),WL4DF (4’ luminaires).Internal Fusing Consult your CFI Fluorescent representative.Radio Interference Filter 120, 277 or 347 volt, 50 or 60Hz. Suffix: R.Lamp Shield K19 acrylic prismatic lens shield on WLRK luminaire.

* For T8 see Wallmaster on page 151.

Drywall FrameCatalogue No., WL2DF (2'), WL4DF (4').

Integral Hanger Luminaire installseasily with adjustable integral hangerthat clamps to T bar. Wire luminairethrough access plate without openinglamp compartment.

Wal-Lyter 24”

Wal-Lyter 48”

WALLW

ASHING OptionalLens

OptionalLens

Page 54: LRG CFI

WLRN124 120 SB

WALL

3'

61

WALL

Recessed LuminairesWallwash

Ordering GuideLamp Lamp Catalogue Numberqty/type watts no lens with lens1-TT5 40W WLRN124 WLRK1241-TT5 50W WLRN125 WLRK1251-TT5 55W WLRN126 WLRK126

Nominal Length 24"

Individual Wal-Lyter Multiple Units0' 1' 2' 3' 4' 5' 6' 7' 8' 4'

Ceiling8' 76 67 46 25 14 8 5 4 3 107 104 102 104 1077' 64 60 46 29 17 10 7 5 4 102 104 106 104 1026' 47 44 36 24 17 12 8 6 4 85 86 88 86 855' 33 34 29 24 14 10 8 6 5 66 74 74 74 664' 26 28 23 20 14 11 8 6 5 59 65 62 65 593' 19 21 20 17 12 9 8 6 5 48 53 56 53 482' 15 16 15 13 11 9 8 6 5 42 44 46 44 421' 13 12 11 11 10 8 7 6 5 38 37 36 37 38

Floor

6'

86 79 63 50 63 79 8678 75 67 58 67 75 7863 62 57 48 57 62 6349 50 48 48 48 50 4942 45 42 40 42 45 4235 36 37 34 37 36 3531 31 31 26 31 31 3128 26 26 22 26 26 27

Ordering GuideLamp Lamp Catalogue Numberqty/type watts no lens with lens2-TT5 40W WLRN244 WLRK2442-TT5 50W WLRN245 WLRK2452-TT5 55W WLRN246 WLRK246

Nominal Length 48"

Footcandles on Wall Luminaires: 3 feet from wall to outside trim on lamp side of luminaire (without lens)* WLRN244BXIndividual Wal-Lyter Multiple Units

0' 1' 2' 3' 4' 5' 6' 7' 8' 6'Ceiling

8' 111 101 76 48 28 18 13 10 9 124 119 104 95 104 119 1247' 113 104 82 56 36 24 17 13 10 130 127 117 111 117 127 1306' 86 81 67 50 35 25 18 13 10 104 106 102 100 102 106 1045' 63 59 51 42 32 24 18 14 11 81 84 83 83 83 83 814' 51 49 43 36 29 23 18 14 11 69 71 72 71 72 71 693' 40 39 35 30 25 21 17 14 11 57 59 60 60 60 59 572' 31 30 28 25 22 19 16 13 11 47 49 50 50 50 49 471' 24 24 23 21 19 17 15 13 11 39 40 41 42 41 40 39

Floor

Multiple Units Continuous Row8' 0' 1' 2' 3' 4' 5' 6' 7' 8'

Ceiling8' 120 111 89 66 57 66 89 111 120 181 182 183 183 184 183 183 182 1817' 124 117 98 79 71 79 98 117 124 200 201 203 203 203 203 203 201 2006' 98 95 85 74 70 74 85 95 98 173 175 176 177 177 177 176 175 1735' 74 74 70 66 64 66 70 74 74 143 146 147 148 148 148 147 146 1434' 62 63 61 58 57 58 61 63 63 125 128 129 130 130 130 129 128 1253' 52 53 52 51 50 51 52 53 52 108 110 111 112 113 112 111 110 1082' 43 44 44 43 43 43 44 44 43 92 94 95 96 96 96 95 94 921' 36 37 37 37 37 37 37 37 36 79 80 81 82 83 82 81 80 77

Floor

Basic catalogue number : Voltage : Ballast : Options :Wal-Lyter 120 See page 60 See page 60

277 Add appropriate347 suffix to catalogue

*Recommended position

Footcandles on Wall Luminaires: 3 feet from wall to outside trim on lamp side of luminaire (without lens)*

WLRN124BX

Page 55: LRG CFI

1800

1200

600

0

30°

60°7-7/8"(178 mm)

4-7/16"(113 mm)

24" (610 mm)

9-7/8" (251 mm)

48" (1219 mm)

7-7/8"(178 mm)

4-7/16"(113 mm)

9-7/8" (251 mm)

3000

2000

1000

0

30°

60°

48" (1219 mm)

7-7/8"(178 mm)

4-7/16"(113 mm)

9-7/8" (251 mm)

1500

1000

500

0

30°

60°

62

Recessed Wallwasher LuminairesWalmaster 2’, 4’Wall Washer / Accent Light • Semi-Specular Optic

WMRL124120BX (Data)

WMRL244120BX (Data)

WMRL143120OC (Data)

Walmaster 24”TT5 lamp

Walmaster 48”TT5 lamp

Walmaster 48”T8 lamp

Integral HangerLuminaire installs easily withhanger clips. Wire luminairethru access plate without opening lamp compartment.

Drywall FrameCatalogue No. WL2DF (2')WL4DF (4').

Walmaster is a cost-effective high performance luminaire that deliversgood light levels and an even wash of light. Low-iridescence semi-spec-ular reflectors do not protrude below the ceiling line. This provides aclean appearance while controlling the light output of a T8 or TT5 lampto illuminate vertical surfaces uniformly.

Features•Low iridescent semi-specular reflector system for precise controlled

light output.•Evenly lights vertical surfaces or displays (no scallops).•87% energy savings vs. incandescent.•Less than 3:1 maximum to minimum wall illumination when installed

6 feet on centre.•20,000 hours lamp life requires less maintenance than incandescent.•No edges protrude below ceiling line.•Can be installed only 2 feet from wall to farthest edge of luminaire

(3' maximum).•Fits all standard and narrow grid ceiling systems.•One-piece body and integral hanger for easy, quick installation.•Sides of luminaire can support tile or sit on T-bar.

Options pages 150-156Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO.Magnetic Electronic PowerSpec Dimming40W TT5: BX 40W TT5: SB 40W TT5: PBT8: OC 50W TT5: BE 50W, 55W TT5: PC

55W TT5: BF T8:PST8: SO (not avail. in 347V)

T12 not available.Drywall Kit For plaster frames, order Cat. No.: WL2DF (2’ luminaire),WL4DF (4’ luminaire).Internal Fusing Consult your CFI Fluorescent representative.Radio Interference Filter 120, 277 or 347 volt, 50 or 60Hz. Suffix: R.

WALLW

ASHING

Page 56: LRG CFI

WMRL124 120 SB

WALL

3'

63

Footcandles on Wall Luminaires: 3 feet from wall to outside trim on lamp side of luminaire* WMRL244120BX

Footcandles on Wall Luminaires: 3 feet from wall to outside trim on lamp side of luminaire* WMRL143120SO

Footcandles on Wall Luminaires: 3 feet from wall to outside trim on lamp side of luminaire* WMRL124120BX

Recessed LuminairesWallwash

INDIVIDUAL WALMASTER MULTIPLE UNITS0' 1' 2' 3' 4' 5' 6' 7' 6'

Ceiling8' 116 88 51 30 19 13 10 8 135 109 77 67 77 110 1377' 119 102 71 45 29 19 14 11 142 130 108 88 109 133 1476' 92 83 64 45 31 22 16 12 117 114 104 99 105 117 1235' 69 64 53 40 30 22 16 13 95 95 92 90 94 99 1024' 52 50 43 35 27 21 17 13 79 80 79 79 81 84 863' 40 39 35 30 24 19 16 13 66 67 67 69 70 71 722' 32 31 29 25 21 17 15 12 56 57 58 59 60 61 611' 26 25 23 21 18 15 13 12 47 49 50 51 51 52 52

Floor

MULTIPLE UNITS CONTINUOUS ROW8' 0' 1' 2' 3' 4' 5' 6' 7' 8'

Ceiling8' 124 97 61 43 37 43 61 97 124 151 134 119 139 162 140 122 140 1627' 128 113 85 65 58 65 85 113 128 166 167 164 176 186 178 170 178 1866' 102 95 80 67 62 67 80 96 102 142 149 152 159 164 162 159 162 1645' 80 77 69 62 59 62 70 77 80 119 126 131 136 139 139 139 139 1394' 64 63 60 56 54 56 60 63 64 100 106 112 115 117 118 119 118 1173' 52 52 51 49 47 49 51 52 52 85 90 94 97 99 100 101 100 992' 43 44 43 42 42 42 43 44 43 73 77 80 83 85 86 86 86 851' 36 36 36 36 36 36 36 36 36 63 66 68 70 72 72 73 72 72

Floor

INDIVIDUAL WALMASTER MULTIPLE UNITS0' 1' 2' 3' 4' 5' 6' 7' 6'

Ceiling8' 49 38 21 12 8 5 4 3 58 46 32 28 32 46 587' 49 42 29 18 12 8 6 4 59 54 44 40 44 54 596' 36 33 25 18 12 8 6 5 48 45 41 39 41 45 485' 27 25 21 16 12 9 7 5 39 38 37 36 37 38 394' 21 20 17 14 11 8 7 5 33 32 32 31 32 32 333' 16 16 14 12 9 8 6 5 28 28 28 28 28 28 282' 13 13 12 10 9 7 6 5 25 24 24 24 24 24 251' 11 10 10 9 8 6 6 5 21 21 21 21 21 21 21

Floor

MULTIPLE UNITS CONTINUOUS ROW8' 0' 1' 2' 3' 4' 5' 6' 7' 8'

Ceiling8' 53 41 26 18 16 18 26 41 53 50 59 68 59 51 59 68 59 507' 52 46 34 26 23 26 34 46 52 67 71 76 72 69 72 76 71 676' 41 38 32 26 24 26 32 38 41 60 63 65 64 63 64 65 63 605' 32 30 27 25 24 25 27 30 32 52 54 55 55 55 55 55 54 524' 25 25 24 22 21 22 24 25 25 46 46 47 47 48 47 46 46 463' 21 21 20 20 19 20 20 21 21 38 39 40 40 41 40 40 39 382' 18 18 18 17 17 17 18 18 18 33 34 35 35 35 35 35 34 331' 15 15 15 15 15 15 15 15 15 28 29 30 30 30 30 30 29 28

Floor

Ordering GuideLamp Lamp Catalogueqty/type watts number2-TT5 40W WMRL2442-TT5 50W WMRL2452-TT5 55W WMRL246

Nominal length 48”

Ordering GuideLamp Lamp Catalogueqty/type watts number1-TT5 40W WMRL1241-TT5 50W WMRL1251-TT5 55W WMRL126

Nominal length 24”

Ordering GuideLamp Lamp Catalogueqty/type watts number1-T8 32W WMRL143

Nominal length 48”

INDIVIDUAL WALMASTER MULTIPLE UNITS CONTINUOUS ROW0’ 1’ 2’ 3’ 4’ 5’ 6’ 7’ 4' 6' 0' 1' 2' 3' 4' 5' 6' 7' 8'

Ceiling8' 52 41 24 13 8 6 5 4 71 64 56 64 71 61 51 35 29 35 51 61 119 122 123 124 124 124 123 122 1197' 56 48 32 19 12 8 6 5 83 79 74 79 83 66 60 47 41 47 60 66 144 149 152 153 153 153 152 149 1446' 43 39 29 19 13 9 7 5 72 70 69 70 72 54 51 45 41 45 51 54 125 131 134 136 136 136 134 131 1255' 32 30 24 18 13 9 7 6 60 60 60 60 60 44 42 40 38 40 42 44 105 109 113 114 115 114 113 109 1054' 24 23 20 15 12 9 7 6 50 50 50 50 50 35 34 34 33 34 34 35 86 91 94 95 96 95 94 91 863' 19 18 16 13 11 9 7 6 41 41 41 41 41 28 28 28 28 28 28 28 71 74 77 78 78 78 77 74 712' 15 14 13 11 9 8 7 6 34 34 34 34 34 24 24 24 24 24 24 24 58 61 63 64 65 64 63 61 581' 12 12 11 10 8 7 7 6 28 28 28 28 28 20 20 20 20 20 20 20 47 50 51 52 52 52 51 50 47

Floor

Basic catalogue number : Voltage : Ballast : Options :Walmaster 120 See page 62 See page 62

277 Add appropriate347 suffix to catalogue

*Recommended position

W

A

L

L

Page 57: LRG CFI

1000

500

0

30°

60°4"(102 mm)

4-3/8"(111 mm)

4"(102 mm)

4-3/8"(111 mm)

150°

120°

90°

500

0

250

708

180°

4-3/8"(111 mm)

24-3/8" (619 mm)

18-3/8" (467 mm)

9/32"

1/2"(13mm)

15/16"(24mm)

7/8"

25-7/8" (657 mm)

4-3/8"(111 mm)

48-11/16" (1237 mm)

43-3/8" (1102 mm)

9/32"

7/8"

50-3/16" (1275 mm)

21-11/16" (551mm)1/2"(13mm)

15/16"(24mm)

4"(102 mm)

4-3/8"(111 mm)

4"(102 mm)

4-3/8"(111 mm)

64

Dia. K.O.

Dia. K.O.

Mounting Hole

Mounting Hole

Surface Wallwasher LuminairesBi-Lyter 2’, 4’Wall Washer Ceiling Mount or Indirect Wall Mount

Features•Same luminaire can be used as a wall washer when ceiling mounted,

or for indirect lighting when wall mounted.•Only 4” deep.•Meets ADA when wall mounted.•Soft rounded corners and edges create an elegant appearance.•20 gauge cold rolled steel body.•Specular reflector.•No visible hardware.•4’ unit: 2-TT5 or 1-T8 lamps.•2’ unit: 1-TT5 lamp.•Matte white baked acrylic finish.•Can be used in continuous rows. Consult factory.•Can be stem mounted.

BLSW124120SB (Data)

BLSW124120SB (Data)

Wall WasherTT5

Indirect Wall MountTT5

Wall Washer T8

2' Unit

Wall Washer

Indirect Wall Mount

C E I L I N G

W

A

L

L

Options pages 150-156Ballast Specify voltage (120 or 277) and add suffix, e.g. 120SO.Magnetic Electronic PowerSpec Dimming— 40W TT5: SB 40W TT5: PB

50W TT5: BE 50W, 55W TT5: PC55W TT5: BF T8: PST8: SO (not avail. in 347V)

T12 not available.Internal Fusing Internal fast-blow fusing. SUFFIX: GLRInternal slow-blow fusing. SUFFIX: GMF.Electrical/Wiring Options Consult factory.For Linear T5 Consult factory.

Note: Fixture N/A for 347V.For continuous row mounting,order part number BLSWCOUPLER for each joint.

Indirect Wall Mount T8

C E I L I N G W

A

L

L

4' Unit

WALLW

ASHING

Page 58: LRG CFI

BLSW126 120 BF

65

51 50 50 50 51

53 53 52 53 53

54 54 53 54 54

53 53 52 53 53

51 50 50 50 51

North wall

Wes

t wal

l East Wall

DK Door South wall

1.68 watts per square foot

17 17 18 19 19 19 19 19 19 19 19 19 19 18 18

17 18 18 19 19 20 19 19 19 19 19 19 19 19 18

17 18 19 19 19 20 19 19 19 19 19 19 19 19 18

18 18 19 19 19 20 20 20 20 20 19 19 19 18 18

18 19 19 19 19 19 19 20 20 20 19 19 19 18 18

18 19 19 19 19 19 19 19 19 20 19 19 18 18 17

17 18 19 19 19 19 19 19 19 19 19 19 18 17 17

Surface / Wall LuminairesWall Washer

Basic catalogue number :Voltage : Ballast : Option :Bi-Lyter 120 See page 64 See page 64Surface Wall or 277 Add appropriateCeiling Mounted suffix to catalogue

number

Footcandles on Wall Luminaires: 3 feet from wall to outside trim on lamp side of luminaire. BLSW124120SBMaintained footcandle readings on wall with 40-watt lamp.

Individual Bi-Lyter Multiple Units Continuous Row0' 1' 2' 3' 4' 5' 6' 7' 8' 4'

Ceiling8' 4 5 6 9 14 25 46 72 86 100 98 92 98 1007' 4 5 6 9 14 24 40 60 70 83 84 81 84 836' 4 5 6 9 13 20 31 42 47 59 63 63 63 595' 4 5 6 7 10 16 22 27 30 40 43 43 43 404' 3 4 5 6 8 10 13 15 17 24 26 26 26 243' 3 3 4 5 6 7 8 9 9 15 16 16 16 152' 3 3 3 4 4 5 5 6 6 10 10 11 10 101' 2 3 3 3 3 4 4 4 4 8 8 8 8 8

Floor

6' 0' 1' 2' 3' 4' 5' 6' 7' 8'

93 82 60 50 60 82 93 157 184 199 204 207 204 199 184 15776 69 54 47 54 69 76 134 158 170 176 178 176 170 158 13453 51 44 41 44 51 53 101 118 128 134 135 134 128 118 10135 35 32 31 32 35 35 71 82 89 93 94 93 89 82 7121 21 21 21 21 21 21 45 51 55 57 58 57 55 51 4513 14 14 14 14 14 13 30 33 35 36 36 36 35 33 309 9 9 9 9 9 9 21 23 24 25 25 25 24 23 217 7 7 7 7 7 7 17 17 18 18 19 18 18 17 17

Corridor Application Corridor maintained footcandle readings at floor level with40 watt lamp (BLSW124120SB). Luminaire mounted 18" from ceiling.

Small Office Application

Only four By-Lyters 55 watt lamp are required toilluminate a 12' x 12' (80/80/50) office space to50 maintained footcandles with only 1.68 wattsper square foot.

Luminaire mounted 18" from ceiling12' x 12' Office Space / 9' Ceiling Height

Reflectance: 80% Ceiling, 80% Wall,50% Floor.

Reported numbers are maintainedfootcandles at desk top level with 55 wattlamp. Footcandle readings will varydepending on room reflectance.

Ordering Guide

Luminaire Lamp Lamp Cataloguelength qty/type watts number24" 1-TT5 40W BLSW12424" 1-TT5 50W BLSW12524" 1-TT5 55W BLSW12648" 2-TT5 40W BLSW24448" 2-TT5 50W BLSW24548" 2-TT5 55W BLSW24648" 1-T8 32W BLSW143

T-Grid MountingOrder Catalog Number : BLSMOUNT

Continuous Row CouplerOrder Catalog Number :BLSWCOUPLER

Wall Mount SpacerFor uneven walls or a floating visual effect. OrderCatalog Number : BLSWSPACER

Page 59: LRG CFI

66

1 1/32"

2 7/16"

A

WATTAGE A

14W 22 19/32" 21W 34 7/16" 28W 46 7/32"

1 1/32"

2 7/16"

A

Features

Slimlyte• 11/32" shallow depth.• Use high efficiency compact linear T5 lamp.• Three nominal lengths: 22-19/32”, 34-7/16”, 46-7/32”.• Grounded convenience outlet, optional.• On/off rocker switch included.• Baked white enamel finish.

OptionsInternal Fusing Add Sufix: F.

Slimlyte TSL

Surface LuminairesSlimlyte T5 (TSL)Under Shelf Task Luminaires

Taskmaster II TCU

SURFACE

Taskmaster II (TCU)

Features

Taskmaster II• 17/8" shallow depth• Four nominal lengths: 18", 24", 36", 48"• Grounded convenience outlet (optional).• On/off switch, optional.• Baked white enamel finish.

OptionsRocker Switch Add Suffix: H (120V only). Grounded Convenience Outlet Add Suffix: CO.Internal Fusing Add Sufix: F.

15W 18 1/8"17W or 20W 24 1/8"25W or 30W 36 1/8"32W or 34W 48 1/8"

Page 60: LRG CFI

67

TSL4128 120 PI

TCU32W 120 SO

Surface Luminaires

Type Luminaire Lamps* Cataloguesize qty/type number

Slimlyte 22-19/32" 1-14W T5 TSL211434-7/16" 1-21W T5 TSL312146-7/32" 1-28W T5 TSL4128

Ordering Guide

Type Luminaire Lamps* Cataloguesize qty/type number

Taskmaster II 18-1/8" 1-15TS TCU15W12024-1/8" 1-20TS TCU20W12036-1/8" 1-25RS TCU25W48-1/8" 1-34RS TCU34W24-1/8" 1-17W T8 TCU17W36-1/8" 1-25W T8 TCU25W48-1/8" 1-32W T8 TCU32W

* TS = Trigger Start T12RS = T12

Ordering Guide

Basic catalogue Voltage : Ballast : Options :number:Slimlyte T5 120 See See page 66Surface luminaire 277 page 66 Add appropriate

suffix to cataloguenumber

Basic catalogue Voltage : Ballast : Options :number:Taskmaster 120 See See page 66Surface luminaire 277 page 66 Add appropriate

347 suffix to cataloguenumber

Page 61: LRG CFI

68

8 Cells 12 Cells

12" (305mm)

5-1/2"(140mm)

•••

•• •

24 Cells

12" (305mm)

5-1/2"(140mm)

60°

30°0°

60°

30°0°

VRB1S24LS232120SO

VRB1S8LS132120SO

VRB 1’ x 4’

VRB 1’ x 4’

8 cells 12 cells

24 cells

Pendant and Surface LuminairesVision Smart Surface 1’x 4’ (VRB)3’’ Deep Cells Parabolic Louver

Features• 20 gauge steel welded body.• Side mounted ballast for cooler operation.• 45° mitered corners (body and louver).• 3" deep cell aluminum parabolic louver.• Spring-loaded latches.• Perfectly uniform four side reveal.• Low-iridescence, semi-specular aluminum, standard.• Louver has polyethylene dust guard.• Louver assembly can be replaced with any of

3 standard Lightolier door frames.

Options pages 150-156Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO.Magnetic Electronic PowerSpec DimmingT8: OC T8: SO T8: PS

For T12 options see page 151. LPB : Number of lamps per ballast. Internal Fusing Consult your CFI Fluorescent representative.Electrical/Wiring Options For special wiring or emergency pack,consult factory.Stem and Canopy Sets Suspend luminaire 12", 18", 24", 36" or 48" fromsurface. (Four per luminaire is recommended.) catalogue Number: STKF12(12"); STKF18 (18"); STKF24 (24"); STKF36 (36"); STKF48 (48").

SURFACE

Page 62: LRG CFI

VRB1S24LS232 120 SO

VRB1S8LS132 120 SO

69

Pendant and Surface Luminaires

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/fixture) 42 95 0.9

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/fixture) 43 85 1.2

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/fixture) 24 95 0.9

Reference Data

Efficiency 48.6%Spacing Ratio 1.2

Electronic Ballast

Input Watts (120V) 62.0W

Ballast Factor 0.88

Reference Data

Efficiency 66.0%Spacing Ratio 1.9

Electronic Ballast

Input Watts (120V) 32.0W

Ballast Factor 0.88

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/fixture) 29 95 0.5

8' x 10' (80 sq ft/fixture) 24 95 0.4

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/fixture) 28 86 0.6

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/fixture) 15 98 0.5

Type Luminaire Cells Lamps Cataloguesize qty/type number

Surface 1 x 4 8 1-T8 VRB1S8LS132Parabolic 1 x 4 12 1-T8 VRB1S12LS132

1 x 4 8 2-T8 VRB1S8LS2321 x 4 12 2-T8 VRB1S12LS232

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :Premium Lensed 120 See page 68 See page 68Surface Luminaire 277 Add appropriate

347 suffix to cataloguenumber

Type Luminaire Cells Lamps Cataloguesize qty/type number

Surface 1 x 4 24 2-T8 VRB1S24LS232Parabolic

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :Premium Lensed 120 See page 68 See page 68Surface Luminaire 277 Add appropriate

347 suffix to cataloguenumber

* Average Footcandles Maintained Total LLF=.82 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens.

Page 63: LRG CFI

24" (610 mm)

5-1/2"(140 mm)

5-1/2"(140 mm)

24" (610 mm)

5-1/2"(140 mm)

24" (610 mm)

9 Cells 12 Cells 16 Cells

24"(610 mm)

1415

1000

500

0

30°

60°

24" (610 mm)

5-1/2"(140 mm)

5-1/2"(140 mm)

24" (610 mm)

5-1/2"(140 mm)

24" (610 mm)2346

1000

500

0

30°

60°

12 Cells 18 Cells 24 Cells 32 Cells

48"(1219 mm)

70

Pendant and Surface LuminairesDeepcel Surface 2’x 2’, 2’x 4’ (DPB)3’’ Deep Cells Parabolic Louver

Features• Only 5-1/2" deep.• Welded 20 gauge steel body.• 45° mitered corners (body and louver).• Side-mounted ballast for cooler operation.• 3" deep aluminum parabolic louver.• Vertical grain on louver eliminates reflected lamp image on cross

baffle.• Matches Deepcel 1 x 4, 2 x 2 and 2 x 4 recessed.• Perfectly uniform four-side black reveal.• Spring-loaded latches.• Reversible louver hinging.• Door jamb with integral positive light stop.• Flush end K.O.’s for smooth surface appearance (at end of row or

individual).• Louver has polyethylene dust guard.

DPB2S9LS26U120SO (Data)

Options pages 150-156Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO.Magnetic Electronic PowerSpec Dimming40W TT5: BX 40W TT5: SB 40W TT5: PBT8: OC 50W TT5: BE T8: PS

55W TT5: BF (not avail. in 347V)3 LPB 40W TT5: X3T8: SO3 LPB T8: O34 LPB T8: O4

For T12 lamp see page 151.LPB : Number of lamps per ballast.Internal Fusing Consult your CFI Fluorescent representative.Electrical/Wiring Options For special wiring or emergency pack,consult factory.Stem and Canopy Sets Suspend luminaire 12", 18", 24", 36" or 48"from surface. (Four per luminaire is recommended.) catalogue number: STKF12 (12"); STKF18 (18"); STKF24 (24"); STKF36 (36");STKF48 (48"). (White finish)Louver Finish Low iridescence semi-specular is standard. Consult factory for other finishes.

DPB2S18LS332120O3 (Data)

RCR C. U.1 622 563 514 465 416 377 338 299 2610 24

RCR C. U.1 752 683 614 555 496 447 398 359 3110 28

DPB 2’ x 2’

DPB 2’ x 4’

12 Cells 18 Cells 24 Cells 32 Cells

9 Cells 12 Cells 16 Cells

SURFACE

Page 64: LRG CFI

DPB2S9LS26U 120 SO

DPB2S18LS332 120 03

71

Pendant and Surface Luminaires

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 50 93 0.9

8' x 10' (80 sq ft/luminaire) 41 94 0.8

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 50 79 1.2

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 30 93 0.9

Type Luminaire Cells Lamps Cataloguesize qty/type number

Surface 2 x 2 9 2-T8U6 DPB2S9LS26UParabolic 2 x 2 12 2-T8U6 DPB2S12LS26U

2 x 2 16 2-T8U6 DPB2S16LS26U2 x 2 9 3-TT5 DPB2S9LS3FT2 x 2 9 3-T8U1.6 DPB2S9LS32U2 x 2 12 3-TT5 DPB2S12LS3FT2 X 2 12 3-T8U1.6 DPB2S12LS32U

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :

Reference Data

Efficiency 57.6%Spacing Ratio 1.4

Electronic Ballast

Input Watts (120V) 60.0WBallast Factor .88

Reference Data

Efficiency 69.6%Spacing Ratio 1.6

Electronic Ballast

Input Watts (120V) 85.0WBallast Factor .88

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 91 91 1.3

8' x 10' (80 sq ft/luminaire) 75 92 1.1

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 89 78 1.8

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 52 97 1.3

Type Luminaire Cells Lamps Cataloguesize qty/type number

Surface 2 x 4 12 2-T8 DPB2S12LS232Parabolic 2 x 4 18 3-T8 DPB2S18LS332

2 x 4 24 3-T8 DPB2S24LS3322 x 4 32 4-T8 DPB2S32LS432

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :Deepcell Surface 120 See page 70 See page 70

277 Add appropriate347 suffix to catalogue

number

* Average Footcandles Maintained Total LLF=.82 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens.

Page 65: LRG CFI

1462

1000

500

0

30°

60°7-1/4"(184mm)

5-1/2"(140mm)

48"(1219mm)

12" (305mm)

4-11/16"(119mm)

48"(1219mm)

2340

2000

1000

0

30°

60°

5-1/2"(140 mm)

24" (610 mm)

5-1/2"(140 mm)

24" (610 mm)

24"(610 mm)

1000

1500

500

0

30°

60°

78 Cells

5-1/2"(140 mm)

24" (610 mm)

5-1/2"(140 mm)

24" (610 mm)

5-1/2"(140 mm)

24" (610 mm)

48"(1219 mm)

1800

2700

900

0

30°

60°

72

ADB

Features•20 gauge steel welded body.•Side mounted ballast for cooler operation.•45° mitered corners (body and louver).•Perfectly uniform four side reveal.•Louver has polyethylene dust guard.ADB•Meets IES RP-1 Preferred luminance criteria.•Louver securely held with concealed Torsiontite springs.•Matte low iridescence, pre-anodized aluminum louver-reflector.•1 x 4 less than 5” deep (4-11/16”).MLB•3-1/2" x 3-1/2" cell aluminum parabolic louver. 1-1/2" deep.•Spring-loaded latches.•Low-iridescence, semi-specular aluminum, standard.• Vertical grain on louver eliminates reflected lamp image on cross baffle.•Louver assembly can be replaced with a regresses aluminium door

(see page 155).

ADB8S16MS132120SO (Data)

ADB1S32MS232120SO (Data)

MLB2S36LS26U120SO (Data)

ADB 8” x 48”

ADB 1’ x 4’

Options pages 150-156Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO.Magnetic Electronic PowerSpec Dimming40W TT5: BX 40W TT5: SB 40W TT5: PBT8: OC 50W TT5: BE T8: PS

55W TT5: BF (not avail. in 347V)3 LPB 40W TT5: X3T8: SO3 LPB T8: O34 LPB T8: O4

For T12 options see page 151. (T12 not available for ADB)LPB : Number of lamps per ballast. Internal Fusing Consult your CFI Fluorescent representative.Electrical/Wiring Options For special wiring or emergency pack,consult factory.Stem and Canopy Sets Suspend luminaire 12", 18", 24", 36" or 48" fromsurface. (Four per luminaire is recommended.) catalogue Number: STKF12(12"); STKF18 (18"); STKF24 (24"); STKF36 (36"); STKF48 (48").

MLB2S78LS332120O3 (Data)

Surface LuminairesVision Smart Surface 8”x 48”, 1’x 4’ (ADB)High Performance Parabolic Louver

RCR C. U.1 672 603 544 495 446 397 358 319 2810 25

Parabaffle Surface 2’x 2’, 2’x 4’ (MLB) MLB 2’ x 2’

MLB 2’ x 4’

36 Cells

78 Cells

RCR C. U.1 672 633 584 545 506 467 438 399 3610 33

RCR C. U.1 682 633 584 535 496 457 428 399 3610 34

RCR C. U.1 622 573 514 465 416 377 338 309 2710 24

16 Cells

32 Cells

SURFACE

Page 66: LRG CFI

ADB8S16MS132 120 SO

ADB1S32MS232 120 SO

MLB2S36LS26U 120 SO

MLB2S78LS432 120 O4

73

Pendant and Surface Luminaires

Reference Data

Efficiency 62.4%Spacing Ratio 1.0

LUMINOUS INTENSITY

55 5cd65° 0cd75° 0cd85° 0cd

Electronic Ballast

Input Watts (120V) 31.0WBallast Factor .88

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 6' (48 sq ft/luminaire) 33 99 0.6

8' x 8' (64 sq ft/luminaire) 25 99 0.5

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 26 99 0.6

8' x 8' x 8.5' Cubicle/60" Partition

8' x 6' (48 sq ft/luminaire) 21 99 0.6

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 46 99 1.0

8' x 10' (80 sq ft/luminaire) 39 99 0.8

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 46 99 1.3

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 31 99 1.0

Reference Data

Efficiency 62.0%Spacing Ratio 1.2

LUMINOUS INTENSITY

55 4cd65° 0cd75° 0cd85° 0cd

Electronic Ballast

Input Watts (120V) 62.0WBallast Factor .88

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 44 84 0.9

8' x 10' (80 sq ft/luminaire) 36 84 0.8

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 43 79 1.2

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 27 84 0.9

Type Luminaire Cells Lamps Cataloguesize qty/type number

Surface 8” x 48” 16 1-T8 ADB8S16MS132Parabolic

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :Vision Smart Surface 120 See page 72 See page 72

277 Add appropriate347 suffix to catalogue

number

Type Luminaire Cells Lamps Cataloguesize qty/type number

Surface 2’ x 2’ 36 2-T8U6 MLB2S36LS26UParabolic 36 3-T8U1.6 MLB2S36LS32U

36 3- TT5 MLB2S36LS3FT

Ordering Guide

Type Luminaire Cells Lamps Cataloguesize qty/type number

Surface 1’ x 4’ 32 2-T8 ADB1S32MS232

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :

Basic catalogue number : Voltage : Ballast : Options :

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 71 95 1.3

8' x 10' (80 sq ft/luminaire) 58 95 1.1

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 70 78 1.8

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 40 97 1.3

Type Luminaire Cells Lamps Cataloguesize qty/type number

Surface 2’ x 4’ 78 2-T8 MLB2S78LS232Parabolic 78 3-T8 MLB2S78LS332

78 4-T8 MLB2S78LS432

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :

Reference Data

Efficiency 57.8%Spacing Ratio 1.5

Electronic Ballast

Input Watts (120V) 60WBallast Factor .88

Reference Data

Efficiency 61.7%Spacing Ratio 1.6

Electronic Ballast

Input Watts (120V) 85WBallast Factor .88

*Average Footcandles Maintained Total LLF=BF (.88) x .85 = .75 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens.

Page 67: LRG CFI

1800

1200

600

0

30°

60°

5-1/2"(140 mm)

12" (305 mm)

5-1/2"(140 mm)

12" (305 mm)

5-1/2"(140 mm)

12" (305 mm)

5-1/2"(140 mm)

24" (610 mm)

24" (610 mm)

5-1/2"(140 mm)

1800

1200

600

0

30°

60°

5-1/2"(140 mm)

24" (610 mm)

5-1/2"(140 mm)

24" (610 mm)

5-1/2"(140 mm)

24" (610 mm)

3600

2400

1200

0

30°

60°

74

Surface LuminairesPrismalyte Surface 1’x 4’, 2’x 2’, 2’x 4’ (PNB)Premium Specification Surface Lens Luminaires

Features•20 gauge welded steel housing.•Housing mitered corner detailing.•Only 5-1/2" deep.•Dual side wireways for cooler operation.•Quick remove ballast covers.•Fully enclosed wiring.•Door jamb with positive light stop.•Positive spring-loaded latches.•Available with floating doors.•Matches Prismalyte Plus troffer (see page 155).•Frames interchangeable with Parabaffle (see page 155).•Side mounted ballast

PNB1SRFVA232120SO (Data)

PNB2SRFVA26U120SO (Data)

PNB2SRFVA432120O4 (Data)

Options pages 150-156Ballast Specify voltage (120, 277 or 347) and add as suffix, e.g. 120SO.Magnetic Electronic PowerSpec Dimming40W TT5: BX 40W TT5: SB 40W TT5: PBT8: OC 50W TT5: BE T8: PS

55W TT5: BF (not avail. in 347V)3 LPB 40W TT5: X31 or 2 LPB T8: SO3 LPB T8: O34 LPB T8: O4

For T12 lamp option see page 151.LPB : Number of lamps per ballast.Internal Fusing Consult your CFI Fluorescent representative.Electrical/Wiring Options For special wiring or emergency pack,consult factory.Stem and Canopy Sets Suspend luminaire 12", 18", 24", 36” and 48”from surface. (Four per luminaire is recommended.) catalogue Number:STKF12 (12"); STKF18 (18"); STKF24 (24"); STKF36 (36"); STKF48 (48")(White finish).Special Lenses VA lens is standard virgin acrylic. For other available lenses, see page 155.

RCR C. U.1 632 563 514 465 416 387 348 319 2810 25

RCR C. U.1 612 553 504 455 406 367 338 309 2710 24

RCR C. U.1 642 573 524 465 416 377 348 309 2710 25

PNB 1’ x 4’

PNB 2’ x 2’

PNB 2’ x 4’

Premium design 5-1/2” deep welded surface box for minimum lampimage on lens surface.

SURFACE

• T12 options are limited due to new regulations.Please consult factory for their availability.

• Please refer to page 13 for more information regarding the availability of T12and the New Energy Efficient regulations set forth by National Resources Canada.

Page 68: LRG CFI

PNB1SRFVA232 120 SO

PNB2SRFVA26U 120 SO

PNB2SRFVA432 120 04

RF

75

Pendant and Surface Luminaires

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 46 66 0.9

8' x 10' (80 sq ft/luminaire) 42 64 0.8

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 46 88 1.2

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 32 97 0.9

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 45 70 0.9

8' x 10' (80 sq ft/luminaire) 41 69 0.8

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 45 86 1.2

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 31 70 0.9

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 94 65 1.8

8' x 10' (80 sq ft/luminaire) 42 64 1.4

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 91 82 2.3

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 61 65 1.8

Type Luminaire Lamps Cataloguesize qty/type number

Surface 1x4 1-T8 PNB1SRFVA132Luminaire 1x4 2-T8 PNB1SRFVA232

1x4 3-T8 PNB1SRFVA332

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :Premium Lensed 120 See page 74 See page 74Surface Luminaire 277

347

Type Luminaire Lamps Cataloguesize qty/type number

Surface 2x4 2-T8 PNB2SRFVA232Luminaire 2x4 3-T8 PNB2SRFVA332

2x4 4-T8 PNB2SRFVA432

Ordering Guide

Type Luminaire Lamps Cataloguesize qty/type number

Surface 2x2 2-T8U6 PNB2SRFVA26ULuminaire 2x2 3-T8U1.6 PNB2SRFVA32U

2x2 3-TT5 PNB2SRFVA3FT

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :

Basic catalogue number : Voltage : Ballast : Options :

Reference Data

Efficiency 58.4%Spacing Ratio 1.2

Electronic Ballast

Input Watts (120V) 62WBallast Factor .88

Reference Data

Efficiency 57.3%Spacing Ratio 1.4

Electronic Ballast

Input Watts (120V) 60WBallast Factor .88

Reference Data

Efficiency 60.2%Spacing Ratio 1.3

Electronic Ballast

Input Watts (120V) 112WBallast Factor .88

Regressed AluminumFloating Door

The Prismalyte Surface Box is available with a regressed aluminum floating door.

* Average Footcandles Maintained Total LLF=.75 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens.

Page 69: LRG CFI

1536

1000

500

0

30°

60°

(102mm)4"

12"(305mm)

(102mm)4"

24"(610mm)

1355

1000

500

0

30°

60°

(102mm)4"

24"(610mm)

3314

2000

1000

0

30°

60°

76

FS RA

Surface LuminairesSLB Surface 1’x 4’, 2’x 2’, 2’x 4’ (SLB)Shallow Design Surface Lens Luminaire

High quality surface luminaires with 4" deep housings. Door frames areextruded aluminum or steel. SLB series surface luminaires can be usedin low plenum depth areas that require surface luminaires. One-piececonstruction for maximum strength.

Features•Shallow 4" deep.•Positive cam-action latches secure frame on either side.•Centre mounted ballast compartment (2 lamps).•Snap-on wiring channel cover is removed without tools.•Matte black light seal on both ends to prevent light leaks.•Spot welded one-piece construction.•Match recessed luminaires serie AA, see page 155.

SLB1SFSVA232120SO (Data)

SLB2SFSVA26U120SO (Data)

SLB2SFSVA432120O4 (Data)

SLB 1’ x 4’

SLB 2’ x 2’

SLB 2’ x 4’

Choice of two SLB door frames

Options pages 150-156Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO.Magnetic Electronic PowerSpec DimmingT8: OC 1 or 2 LPB T8: SO T8: PS

3 LPB T8: O3 (not avail. in 347V)4 LPB T8: O4

For T12 lamp options see page 151.LPB : Number of lamps per ballast. Internal Fusing Consult your CFI Fluorescent representative.Electrical/Wiring Options For special wiring or emergency pack,consult factory.Stem and Canopy Sets Suspend luminaire 12", 18", 24", 36" or 48" fromsurface. (Four per luminaire is recommended.) catalogue Number: STKF12(12"); STKF18 (18"); STKF24 (24"); STKF36 (36");STKF48 (48").Special Lenses VA lens is standard virgin acrylic. For other available lenses, see page 155.

Flush Steel (Standard) Regressed Aluminum

RCR C. U.1 602 543 484 445 396 367 328 299 2610 24

RCR C. U.1 712 643 574 515 466 417 378 349 3010 28

Note: For Regressed Aluminium Door Frame, replace FS by RA in thebasic catalogue number.

RCR C. U.1 682 613 544 495 446 397 368 329 2910 26

SURFACE

Page 70: LRG CFI

SLB1SFSVA132 120 SO

SLB2SFSVA26U 120 SO

SLB2SFSVA432 120 O4

77

Pendant / Surface

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 50 66 0.9

8' x 10' (80 sq ft/luminaire) 40 63 0.8

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 50 88 1.2

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 35 97 0.9

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 50 70 0.9

8' x 10' (80 sq ft/luminaire) 40 70 0.8

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 50 86 1.2

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 31 70 0.9

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 105 65 1.8

8' x 10' (80 sq ft/luminaire) 84 64 1.4

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 101 82 2.3

8' x 8' x 8.5' Cubicle/60" Partition

8' x 8' (64 sq ft/luminaire) 68 97 1.8

Type Door Luminaire Lamps Catalogueframe size qty/type number

Surface Flush 1 x 4 1-T8 SLB1SFSVA132Lens Steel 1 x 4 2-T8 SLB1SFSVA232

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :SLB Surface 120 See page 76 See page 76

277347

Type Door Luminaire Lamps Catalogueframe size qty/type number

Surface Flush 2 x 4 2-T8 SLB2SFSVA232Lens Steel 2 x 4 3-T8 SLB2SFSVA332

2 x 4 4-T8 SLB2SFSVA432

Ordering Guide

Type Door Luminaire Lamps Catalogueframe size qty/type number

Surface Flush 2 x 2 2-T8U6 SLB2SFSVA26ULens Steel 2 x 2 4-T8 SLB2SFSVA417

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :

Basic catalogue number : Voltage : Ballast : Options :

Reference Data

Efficiency 56.2%Spacing Ratio 1.2

Electronic Ballast

Input Watts (120V) 62WBallast Factor .88

Reference Data

Efficiency 63.6%Spacing Ratio 1.3

Electronic Ballast

Input Watts (120V) 60WBallast Factor .88

Reference Data

Efficiency 67.1%Spacing Ratio 1.3

Electronic Ballast

Input Watts (120V) 112WBallast Factor .88

* Average Footcandles Maintained Total LLF=.75 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens.

One-piece construction.

Page 71: LRG CFI

1517

1000

500

0

30°

60°

78

* See TriLyte at pages 102-104 for T5 Fluorescent Gym Application options

Surface LuminairesGymlyte 4’, 8’ (GM)Heavy Duty Surface Luminaire

Gymlyte features a spot welded construction, heavy gauge steel one-piece housing. It comes complete with wire guard or door framewith lens and wire guard. The wire guard is welded to the door framewhen a door frame is specified. Specular reflectors are also available.All surfaces are post painted with white baked polyester enamel.

GM4B4SVA232120SO (Data)

Features• Welded 20 gauge chassis for superior strength.• Side mounted ballast for low 4-1/8” deep profile.• Wire guard or door, hinged.• Wire guard or door, latched with screw.• Stem or surface mounted.• Available with inside silver reflector.• Wireguard with or without door frame (see options).

Options pages 150-156Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO.Magnetic Electronic PowerSpec DimmingT8: OC T8: SO T8: PS

3 LPB T8: O3 (not avail. in 347V)4 LPB T8: O42 x 3 LPB T8: O6

For T12 option see page 151.LPB : Number of lamps per ballast.Door / Lens for Gymlyte When a lens is specified (e.g. VB), the unit is supplied with a steel door frame and heavy duty wire guard. When alens is not required (e.g. XX), the unit is supplied with a heavy dutywire guard only.Electrical/Wiring Options Consult factory.Stem and Canopy Sets Order Catalogue Number STKF12 (12"),STKF18 (18"), STKF24 (24"), STKF36 (36"), STKF48 (48").4 Stem per luminaire is recommended.

RCR C. U.1 632 573 514 455 416 377 338 309 2710 24

SURFACE

Gymlyte 4’ and 8’ narrow

Gymlyte 4’ wide body

Page 72: LRG CFI

GM4B4SVB232 120 SO

GM 4 B 4 S VB 2 32 120 SO

79

Pendant / Surface

Application Data*

Luminaire Spacing FC W/Sq Ft

50' x 70' x 12' Space

12' on centre 56 1.2

50' x 70' x 8.5' Space

10' on centre 71 1.3

50' x 70' x 8.5' Space

12' on centre 61 1.2

30' x 30' x 8.5' Space

12' on centre 60 1.4

Type Lamps Lamp/Luminaire Luminaire Catalogueqty/type Nominal Length width number

Prismatic 2-T8 48” 12-15/16” GM4B4SVB232Lens Luminaire 3-T8 48” 12-15/16” GM4B4SVB332with 3-T8 48” 16-15/16” GM4B5SVB332Wireguard in 4-T8 48” 16-15/16” GM4B5SVB432Door Frame 4-T8 96” tandem 12-15/16” GM8B4SVB232

6-T8 96” tandem 12-15/16” GM8B4SVB332Lens and 2-T8 48” 12-15/16” GM4B4WGVB232Wireguard 3-T8 48” 12-15/16” GM4B4WGVB332No 3-T8 48” 16-15/16” GM4B5WGVB332Door Frame 4-T8 48” 16-15/16” GM4B5WGVB432

4-T8 96” tandem 12-15/16” GM8B4WGVB2326-T8 96” tandem 12-15/16” GM8B4WGVB332

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :Gymlyte 120 See below. See belowLuminaire 277 Add appropriate

347 suffix to cataloguenumber

Reference Data

Efficiency 59.6%Spacing Ratio 1.2

Electronic Ballast

Input Watts (120V) 62.0WBallast Factor .88

* Average Footcandles Maintained Total LLF=BF (.88) x .85 = .75 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens.

LuminaireTypeGM: Gymlyte

LuminaireLenght4: 4’8: 8’

Body StyleB: Surface Box

Width4: 12-15/16”5: 16-15/16”

Ceiling TypeS: Wireguard

with Welded Door Frame

WG: Wireguardwith no door frame

Lens/ShieldingVB: Pattern 12lens .125” nomi-nal - Prismaticlens.VX: Pattern 12lens .125”polycarbonate.KA: Pattern 19lens .156” nomi-nal - Prismaticlens.XX: No lenswith Wire Guard

LampQuantity in aluminairecross-section2: 2 lamps3: 3 lamps4: 4 lamps

Lamp/Type32: T8 32W 34: T12 34W

Voltage120277347

BallastLE: T12MagneticOC: T8 MagneticSO: 1-2 lampElectronicO3: 3 LPB T8ElectronicO4: 4 LPB T8ElectronicO6: 2 x 3 LPB T8Electronic

Ordering Guide

OptionsAdd appropriatesuffix to cataloguenumbersee pages 78.

Page 73: LRG CFI

1817

1000

500

0

30°

60°3-1/4"

(83 mm)

12" (305 mm)

4-7/8"(124mm)

4-1/2"(114mm)

97"(2464mm)

48-1/2"(1232mm)

13-5/8"(346mm)

97"(2464mm)

8-5/8"(219mm)

4-1/8"(105mm)

48-1/2"(1232mm)

1249

1000

500

0

30°

60°

80

8-5/8"(219mm)

4-1/8"(105mm)

Features• .187 lens thickness.• Five side injection molded refractor with square base, conical prisms

(absolutely no sag).• Catadioptric side/end wall design, for low brightness.• Tight aligning refractor fit.• Invisible spring steel latches.• Easy ballast accessibility.• Rigid, reinforced housing.• Individual or continuous row mounting.

CBS232120SO (Data)

Options pages 150-156Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO.Magnetic Electronic PowerSpec DimmingT8: OC 1 or 2 LPB T8: SO T8: PST12: LE 3 LPB T8: O3 (not avail. in 347V)

4 LPB T8: O4For CBS with T12 see page 151.LPB : Number of lamps per ballast.Internal Fusing Consult your CFI Fluorescent representative.Electrical/Wiring Options For special wiring or emergency pack,consult factory.Canopy Spacer Suspends luminaire 1-1/2" from surface.Order Catalogue Number STSK.Stem and Canopy Order Catalogue Number STKF12 (12"),STKF18 (18"), STKF24 (24"), STKF36 (36"), STKF48 (48"). (White finish)Celebrity Surface not recommended for Stem Mounting.Lens Holophane 7100 lens standard. For pattern 19 : suffix KA.For parttern 12 : suffix VB.

Surface LuminairesCelebrity Surface (CBS)Premium Prismatic Surface Lens Luminaire

RCR C. U.1 772 693 624 565 516 467 428 389 3410 31

TH248-120LE (Data)

Features• A one-piece wrap lens with opaque end caps.• High lighting efficiency.• Suitable for surface or pendant mounting.• Ideal school luminaire.• Optional silver reflector

Director-2 (TH)Premium Wrap Surface Luminaire

RCR C. U.1 732 653 584 525 466 427 378 339 3010 27

A true high quality injection molded lens. Low glare optic with an architectural appearance and luminous ends.

Celebrity 12”x 49 9/16”

Director-2

SURFACE

• T12 options are limited due to new regulations.Please consult factory for their availability.

• Please refer to page 13 for more information regarding the availability of T12and the New Energy Efficient regulations set forth by National Resources Canada.

Page 74: LRG CFI

CBS232 120 SO

TH248T 120 04

81

Sturdy steel chassis Four sided injection molding

* Average Footcandles Maintained Total LLF=.75 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens.

Pendant / Surface

Application Data*

Luminaire Spacing FC W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 56 0.9

30' x 30' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 56 0.9

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 64 1.2

Type Luminaire Luminaire Lamps Cataloguewidth length qty/type number

SurfacePrismatic 12" 49-9/16" 2-T8 CBS232Luminaire

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :Surface Prismatic Lens 120 See page 80 See page 80Luminaire 277

347

Reference Data

Efficiency 73.1%Spacing Ratio 1.4

Electronic Ballast

Input Watts (120V) 62WBallast Factor .88

photograph illustratesaction of Celebrity lens enclosure. Catadioptric prisms “mirror” out glare,refract ligh beams into useful areas.

Application Data*

Luminaire Spacing FC W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 54 0.9

30' x 30' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 53 0.9

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 59 1.2

Type Lamps Lamp/Luminaire Luminaire Catalogueqty/type Nominal length width number

Prismatic 1-T8/T12 48” 4 7/8” TH148Lens 1-T8/T12 48” 8 5/8” TH1W8Luminaire 2-T8/T12 48” 8 5/8” TH248

2-T8/T12 48” 13 5/8” TH2W83-T8/T12 48” 13 5/8” TH3484-T8/T12 48” 13 5/8” TH448 †

Tandem 2-T8/T12 96” Tandem 4 7/8” TH148T2-T8/T12 96” Tandem 4 7/8” TH1W8T4-T8/T12 96” Tandem 8 5/8” TH248T

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :

Reference Data

Efficiency 72.7%Spacing Ratio 1.8

Electronic Ballast

Input Watts (120V) 89.3WBallast Factor .88

† Consult factory, available in large quantity only.

Page 75: LRG CFI

1737

1000

500

0

30°

60°

90°

375

375

250

250

125

125

500

500

180° 150°

120°

0

30°

60°

82

2-5/8"(67 mm)

9" (229 mm)

2-5/8"(67 mm)

14" (356 mm)

14" (356 mm)

2-5/8"(67 mm)

4-1/4"(107.9 mm)

5-3/4"(146 mm)

4-1/4"(107.9 mm)

5-3/4"(146 mm)

RCR C. U.1 682 603 544 485 436 397 358 329 2910 26

RCR C. U.1 772 673 594 525 466 417 378 339 3010 27

Features• Step-back housing for an apparent depth of 1-1/2".• Floating panel of light effect.• A shallow profile and linear prismatic sides combine to reduce

ceiling contrast.• Shielding hinges the unit’s entire length for safety and ease of

maintenance.• Snap-on components provide time-saving installation.• Suitable for mounting on low-density cellulose fiberboard surfaces.• Not recommended for row mounting.

TT248-120SO (Data)

TN148-120SO (Data)

Options pages 150-156Ballast Specify voltage (120, 277 in 347) and add suffix, e.g. 120SO.Magnetic Electronic PowerSpec DimmingT8: OC T8: SO T8: PST12: LE 4 LPB T8: O4 (not avail. in 347V)LPB : Number of lamps per ballast.Electrical/Wiring Options For special wiring or emergency packs,consult factory.Canopy Spacer Suspends luminaire 1-1/2" from surface. Order cataloguenumber STSK.Stem and Canopy Sets Suspends luminaire 12", 18" 24", 36" or 48" from sur-face. Order catalogue number STKF12 (12"), STKF18 (18"), STKF24 (24"),STKF36 (36"), STKF48 (48"). (White finish)Internal Fusing Consult your CFI Fluorescent representative.

Surface LuminairesDominaire Surface 4’ (TT)Specification Surface Wrap Luminaire

Dominaire Corridor 2’, 4’, 8’ (TN)Narrow Surface Wrap Luminaire

Options pages 150-156Ballast Specify voltage (120, 277 or 347) and add as suffix, e.g. 120SO.Magnetic Electronic PowerSpec DimmingT8: OC T8: SO T8: PST12: LE 3 LPB T8: O3 (not avail. in 347V)

4 LPB T8: O4LPB : Number of lamps per ballast.Electrical/Wiring Options For special wiring or emergency packs,consult factory.Canopy Spacer Suspends luminaire 1-1/2" from surface. Order cataloguenumber STSK.Stem and Canopy Sets Suspends luminaire 12", 18" 24", 36" or 48" fromsurface (Four per luminaire is recommended) .Order catalogue number STKF12(12"), STKF18 (18"), STKF24 (24"), STKF36 (36"), STKF48 (48") (White finish).Internal Fusing Consult your CFI Fluorescent representative.

Features•A shallow profile and linear prismatic sides combine to reduce

ceiling contrast.•Shielding hinges the unit’s entire length for safety and ease of

maintenance.•Snap-on components provide time-saving installation.•Suitable for mounting on low-density cellulose fiberboard surfaces.

SURFACE

• T12 options are limited due to new regulations.Please consult factory for their availability.

• Please refer to page 13 for more information regarding the availability of T12 and the New Energy Efficient regulations set forthby National Resources Canada.

• T12 options are limited due to new regulations.Please consult factory for their availability.

• Please refer to page 13 for more information regarding the availability of T12 and the New Energy Efficient regulations set forthby National Resources Canada.

Page 76: LRG CFI

TT248 120 SO

TT448 120 04

TN248 120 SO

83

Type Lamp Lamp/Luminaire Luminaire Catalogueqty/type nominal length width number

Prismatic 2-T8 / T12 48" 9" TT248Lens Luminaire

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :Dominaire Surface 120 See page 82 See page 82

277347

Type Lamp Lamp/Luminaire Luminaire Catalogueqty/type nominal length width number

Prismatic 1-T8 / T12 24" 5-3/4" TN124Lens 2-T8 / T12 24" 5-3/4" TN224Luminaire 1-T8 / T12 48" 5-3/4" TN148

2-T8 / T12 48" 5-3/4" TN2482-T8 / T12 96" 5-3/4" TN148T(tandem)

4-T8 / T12 96" 5-3/4" TN248T(tandem)

Ordering Guide

Type Lamp Lamp/Luminaire Luminaire Catalogueqty/type nominal length width number

Prismatic 2-T8 / T12 48" 14" TT2W8Lens 3-T8 / T12 48" 14" TT348Luminaire 4-T8 / T12 48" 14" TT448

Ordering Guide

Reference Data

Efficiency 66.0%Spacing Ratio 1.2

Electronic Ballast

Input Watts (120V) 62.0WBallast Factor .88

Reference Data

Efficiency 81.0%Spacing Ratio 1.6

Electronic Ballast

Input Watts (120V) 31.0WBallast Factor .88

* Average Footcandles Maintained Total LLF=.75 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens.

Application Data*

Luminaire Spacing FC W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 49 0.9

30' x 30' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 48 0.9

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 54 1.2

Application Data*

Luminaire Spacing FC W/Sq Ft

4' W x 8.5' H Corridor

39 1,7

6' W x 8.5' H Corridor

36 1.1

8' W x 8.5' H Corridor

33 0.8

RCR C. U.1 692 613 544 495 436 397 358 329 2810 26

Basic catalogue number : Voltage : Ballast : Options :

Basic catalogue number : Voltage : Ballast : Options :

Reference Data

Efficiency 65.5%Spacing Ratio 1.3

Electronic Ballast

Input Watts (120V) 112WBallast Factor .88

Application Data*

Luminaire Spacing FC W/Sq Ft

50' x 70' x 8.5' Space

8' x 10' (80 sq ft/luminaire) 83 1.4

30' x 30' x 8.5' Space

8' x 10' (80 sq ft/luminaire) 77 1.4

12' x 16' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 90 1.8

TT448-120SO (Data)

Pendant / Surface

Page 77: LRG CFI

1549

1000

500

0

30°

60°

2-5/8"(67 mm)

9" (229 mm)

48"(1219 mm)

2984

2000

1000

0

30°

60°

3-3/16"(81mm)

14" (356 mm)

48"(1219 mm)

84

8-1/4" (210mm)

3/8"(10mm)

3-5/8"(92mm)

50-1/8" 26-1/8"

250

150

0

30°

60°

350

450

90°

Surface LuminairesWrap 9”x 48”, 14”x 48” (TX)Prismatic Surface Wrap Lens Luminaire

Features•Floating panel of light effect.•A shallow profile and linear prismatic sides combine to reduce ceiling

contrast.•Shielding hinges the unit’s entire length.•Snap-on components provide time-saving installation.•Suitable for mounting on low-density cellulose fiberboard surfaces.

9” wide 4’ nominal lengths.14” wide 4’ nominal lengths.

•Can be row mounted.

TX248-120SO (Data)

TX448-120O4 (Data)

Options pages 150-156Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO.Magnetic Electronic PowerSpec DimmingT8: OC T8: SO T8: PST12: LE 3 LPB T8: O3 (not avail. in 347V)

4 LPB T8: O4LPB : Number of lamps per ballast.Electrical/Wiring Options For special wiring or emergency packs, consult factory.Internal Fusing Consult your CFI Fluorescent representative.Canopy Spacer Suspends luminaire 1-1/2” from surface. Order catalogue number STSK.Stem and Canopy Suspends luminaire 12”, 18”, 24”, 36” or 48” from surface. Order catalogue number STKF12 (12”), STKF18 (18”),STKF24 (24”), STKF36 (36”), STKF48 (48”) (White finish).

RCR C. U.1 792 703 624 565 506 457 418 379 3310 30

RCR C. U.1 692 613 544 495 436 397 358 329 2810 26

9” x 48”

14” x 48”

SURFACE

Features• Heavy duty 16 gauge cold rolled steel housing.• Wall or ceiling mounts.• Clear injection molded polycabonate lens for toughness.• Lens secured with vandal-proof screws.• Easily removable ballast cover.• Polycarbonate lens only 3-5/8” deep, ideal for low ceilings.• 52.4% efficient.• Also available as a 2’ model.

Options pages 150-156Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO.Magnetic ElectronicRS T12: LET8: OC 1 or 2 LPB T8: SOLPB : Number of lamps per ballast.Electrical / Wiring Options Consult factory.Fluorescent Emergency Lighting System Factory installed emergencypower battery pack with charger and inverter. Suffix : O.

VA248-12050 (Data)8” x 50”

Vandal 8”x 50” (VA) Surface Vandal Resistant Wrap Lens Luminaire

• T12 options are limited due to new regulations.Please consult factory for their availability.

• Please refer to page 13 for more information regarding the availability of T12 and the New Energy Efficient regulations set forthby National Resources Canada.

• T12 options are limited due to new regulations.Please consult factory for their availability.

• Please refer to page 13 for more information regarding the availability of T12 and the New Energy Efficient regulations set forth byNational Resources Canada.

Page 78: LRG CFI

TX248 120 SO

TX448 120 04

85

VA248 120 SO

Pendant and Surface Luminaires

Application Data*

Luminaire Spacing FC W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 49 0.9

30' x 30' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 48 0.9

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 54 1.3

Application Data*

Luminaire Spacing FC W/Sq Ft

50' x 70' x 8.5' Space

8' x 10' (80 sq ft/luminaire) 83 1.4

30' x 30' x 8.5' Space

8' x 10' (80 sq ft/luminaire) 77 1.4

12' x 16' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 90 1.8

Type Lamp Lamp/Luminaire Luminaire Catalogueqty/type nominal length width number

Prismatic 2-T8/T12 48" 9” TX248LensLuminaire

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :Premium Wrap 120 See page 84 See page 84Low profile 277

347

Type Lamp Lamp/Luminaire Luminaire Catalogueqty/type nominal length width number

Prismatic 2-T8/T12 48" 14" TX2W8Lens 3-T8/T12 48" 14" TX348Luminaire 4-T8/T12 48" 14" TX448

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :

Reference Data

Efficiency 76.0%Spacing Ratio 1.3

Electronic Ballast

Input Watts (120V) 62WBallast Factor .88

Reference Data

Efficiency 65.5%Spacing Ratio 1.3

Electronic Ballast

Input Watts (120V) 112WBallast Factor .88

* Average Footcandles Maintained Total LLF=.75 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens.

Type Class/ Luminaire Lamp Cataloguedivision length type number

Vandalism 8” x 50” 1-T8 / T12 48” VA148Wall / Surface 8” x 50” 2-T8 / T12 48” VA248Statique 8” x 26” 2-T8 / T12 24” VA224

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options : Vandal Luminaire 120 See page 84 See page 84

277 Add appropriate347 suffix to catalogue

number

Page 79: LRG CFI

6"(152mm)

5-3/16"(132mm)

CCWLN 4

90°

150

150

200

250

300

350

400

100

100

50

50

180° 150° 120°

0

30°

60°

86

(CTW)

(CSW)

Surface LuminairesCubelite 24”, 36”, 48” (CSB, CSW, CTW)Surface / Wall Luminaire • Prismatic / Opal Lens

Cloud Bracket 24”, 36”, 48” (CCW)Surface / Wall LuminaireDecorative Diffuser

Features•Soft diffused lighting provides even illumination in decorative

residential and high-style commercial applications.•Soft curvature white acrylic diffuser.•Wall mounted design for bathroom, corridors or hallways.•Complementary design to the Belmont Cloud (see page 90).•Complete luminaire consists of Lens Assembly and Strip fixture.

Order each item separately.•Not suitable for row mounting

Options pages 150-156Ballast Specify voltage (120, 277 or 347V) to Surface Strip fixture andadd suffix, e.g.120SO.Magnetic Electronic PowerSpec DimmingT8: OC T8: SO T8: PS

(not avail. in 347V)

Ordering Guide

Basic catalogue number: Length:Cloud Bracket Lens 4'

Features• Only 4-3/4” deep.• Smooth opal acrylic diffuser standard (ZO).• Suitable for mounting on low density surfaces.• Individual or continuous row mounting.• Spring-loaded end cap (CSW and CSB only).• Also available with a clear prismatic lens (VB).• Convenience outlet optional.• Choice of white (CSW) or black (CSB) housing.• CTW features fixed encaps and prismatic lens

CSW148-120LEZO (Data)

RCR C. U.1 682 583 514 445 396 347 318 279 2510 22

OptionsBallast Specify voltage (120, 277 or 347) to surface strip fixture and add suffix,e.g. 120SO.Magnetic Electronic PowerSpec DimmingT8: OC T8: SO T8: PST12: LE (not avail. in 347V)For Cubelite consult factory on 2' length ballast options.Diffuser for Cubelite: Suffix ZO = Opal Acrylic (standard)

VB = Prismatic AcrylicElectrical/Wiring Options For special wiring or emergency packs,consult factory.Internal Fusing Consult your CFI Fluorescent representative.Body colour Replace CSW (white) by CSB (black) in the basic catalogue number.For non spring-loaded end caps, replace CS by CT in the basic catalogue number.

SURFACE

Type Length Width Height Ordered With Lamp Catalogue Qty/Type Number

Cloud 26-3/4" 6" 4-1/2" SB1W2 1-T8 CCWLN2Bracket 38-3/4" 6" 4-1/2" SB1W3 1-T8 CCWLN3Diffuser 50-3/4" 6" 4-1/2" SB1W4 1-T8 CCWLN4

Cloud 26-3/4" 6" 4-1/2" SB224 2-T8 CCWLN2Bracket 38-3/4" 6" 4-1/2" SB236 2-T8 CCWLN3Diffuser 50-3/4" 6" 4-1/2" SB248 2-T8 CCWLN4

• T12 options are limited due to new regulations.Please consult factory for their availability.

• Please refer to page 13 for more information regarding the availability of T12 and the New Energy Efficient regulations set forth byNational Resources Canada.

* 1-Lamp profile* Available in 1 and 2 lamp combinations

Page 80: LRG CFI

CVWLN 4 SW

CSW124 120 SO ZO

4-11/16"(119mm)

4-1/16"(103mm)

87

Surface / Wall-Mount

Type Length Width Height Ordered Lamp Cataloguewith Qty/Type Number

Smooth 25-3/8" 4-3/4" 4" SB124 1-T8 CVWLN2-SWWhite 37-3/8" 4-3/4" 4" SB136 1-T8 CVWLN3-SW

49-3/8" 4-3/4" 4" SB148 1-T8 CVWLN4-SW

Fluted 25-3/8" 4-3/4" 4" SB124 1-T8 CVWLN2-FWWhite 37-3/8" 4-3/4" 4" SB136 1-T8 CVWLN3-FW

49-3/8" 4-3/4" 4" SB148 1-T8 CVWLN4-FW

Fluted 25-3/8" 4-3/4" 4" SB124 1-T8 CVWLN2-FCClear 37-3/8" 4-3/4" 4" SB136 1-T8 CVWLN3-FC

49-3/8" 4-3/4" 4" SB148 1-T8 CVWLN4-FC

Ordering Guide

Basic catalogue number: Length: Acrylic Variation:Vanity Bracket Lens 4' Smooth White

Features•Choice of 3 basic modules and 3 distinctive acrylic variations in

aesthetics and performance.Smooth White - accentuates the simplicity of a smooth,

diffused surfacesFluted White - features an elegant, fluted design with

hint of opalescenceFluted Clear - emphasizes a bold fluted lens.

•Molded ends.•Wall mounted.•Complete luminaire consists of Lens Assembly and Strip fixture.

Order each item separately.•Not suitable for row mounting

Options pages 150-156Ballast Specify voltage (120, 277 or 347V) to Surface Strip fixture andadd suffix, e.g.120SO.Magnetic Electronic PowerSpec DimmingT8: OC T8: SO T8: PS

(not avail. in 347V)

Vanity Bracket 24”, 36”, 48” (CVW)Surface / Wall Luminaire • Decorative Diffuser

Application Data*

Luminaire Spacing FC W/Sq Ft

4' W x 8.5' H Corridor

39 1,7

6' W x 8.5' H Corridor

36 1.1

8' W x 8.5' H Corridor

33 0.8

Type Lamp Lamp/Luminaire Luminaire Catalogueqty/type nominal length width number

Cubelite 1-T8/T12 24" 4" CSW1242-T8/T12 24" 4" CSW2241-T8/T12 36" 4" CSW1362-T8/T12 36" 4" CSW2361-T8/T12 48" 4" CSW1482-T8/T12 48" 4" CSW2481-T8/T12 24" 4 5/16" CTW1242-T8/T12 24" 4 5/16" CTW2241-T8/T12 36" 4 5/16" CTW1362-T8/T12 36" 4 5/16" CTW2361-T8/T12 48" 4 5/16" CTW1482-T8/T12 48" 4 5/16" CTW248

Ordering Guide

Spring-loaded end cap (CSB and CSW).

Basic catalogue number : Voltage : Ballast : Options :Cubelite 120 See page 86 ZO: Opal

277 VB: Prismatic347

Reference Data

Efficiency 72.9%Spacing Ratio 1.7

Electronic Ballast

Input Watts (120V) 62WBallast Factor .88

* Only available in 1-lamp options

CTW only available in VB.

Page 81: LRG CFI

12330°

500

0

30°

60°

7-5/8" (193.6 mm)

3-1/16"(77.7 mm)

7-5/8" (193.6 mm)

3-1/16"(77.7 mm)

8710°

500

512

0

30°

60°

90°

120°

150°

180°

7-5/8" (193.6 mm)

3-1/16"(77.7 mm)

7-5/8" (193.6 mm)

3-1/16"(77.7 mm)

1354

500

0

30°

60°

9540°

500

525

0

30°

60°

90°

120°

150°

180°

88

Pendant / SurfaceCelebrity Wall 24”, 48” (CWBU)Premium Wall-Mount • Direct or Direct / Indirect Luminaire

CWBU Series (Celebrity)...The ultimate in glare-free architectural light-ing. A classic linear wall luminaire with a jewel-like diamond facetedinjection molded refractor, that mirrors out brightness at critical viewingangles. Typical applications: Over mirrors, over bed, corridors, stairwellsand bulletin boards.

Features•Low brightness controlled downlighting or uplighting/downlighting.•Injection-molded one-piece virgin acrylic downlight refractor.•Removal of back panel allows in the field conversion of direct fixture

to direct/indirect fixture.•Catadioptric side and end wall design downlight for low brightness.•Slim 3-1/16” height.•Nominal 2’ and 4’ lengths.•Invisible steel latches align refractor to housing.•Individual or continuous rows.

CWBU232120SO (Downlight Data)

CWBU232120SO (Uplight / Downlight Data)

LWBU232120SO (Downlight Data)

LWBU232120SO (Uplight / Downlight Data)

DirectCWBU

Direct / IndirectCWBU

DirectLWBU

Direct / IndirectLWBU

Options pages 150-156Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO.Magnetic ElectronicT8: OC T8: SOFor T12 consult factory.2-Way Pull Switch (120V luminaires only.) Add suffix K (right position)or L (left position) to catalogue number.Grounded Convenience Outlet Add Suffix: CO. (Factory Installed).Electrical/Wiring Options For special wiring, fusing, electronic dimming ballasts or emergency packs, consult factory.

RCR C. U.1 652 573 514 465 416 387 348 319 2910 27

RCR C. U.1 652 573 514 455 376 337 308 289 2610 24

RCR C. U.1 642 563 494 445 396 357 328 299 2610 24

Features•Low brightness controlled downlighting or uplighting/downlighting.•Low brightness linear prismatic virgin acrylic refractor.•Slim 3-1/16” height.•Nominal 2’, 3’ and 4’ lengths.•Invisible steel latches align refractor to housing.•Removal of back plate allows in the field conversion of direct fixture

into a direct/indirect fixture.•Individual or continuous rows.

LWBU Series... A traditional linear wall luminaire with a crisplinear prismatic virgin acrylic refractor that controls brightness. Typicalapplications : over mirrors, over beds, corridors, stairwells and bulletinboards.

LWB 24”, 36”, 48” (LWBU)Standard Wall Mount/Direct or Direct/Indirect Luminaire

RCR C. U.1 642 563 494 445 396 357 328 299 2710 25

SURFACE

Page 82: LRG CFI

CWBU117 120 SO

LWBU132 120 SO

89

Surface / Wall-Mount

Type Luminaire Lamp Lamp Cataloguelength qty/type length number

Downlight 25-1/2" 1-T8 24” CWBU11749-1/2” 1-T8 48” CWBU132

Downlight 25-1/2" 2-T8 24” CWBU21749-1/2” 2-T8 48” CWBU232

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :Celebrity Wall 120 See page 88 See page 88

277 Add appropriate347 suffix to catalogue

number

Type Luminaire Lamp Lamp Cataloguelength qty/type length number

Downlight 25-1/2" 1-T8 24” LWBU11737-1/2” 1-T8 36” LWBU12549-1/2” 1-T8 48” LWBU132

Downlight 25-1/2" 2-T8 24” LWBU21737-1/2” 2-T8 36” LWBU22549-1/2” 2-T8 48” LWBU232

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :

Reference Data

Efficiency 63%

Electronic Ballast

Input Watts (120V) 62.0WBallast Factor .88

Reference Data

Efficiency 67.1%

Electronic Ballast

Input Watts (120V) 62.0WBallast Factor .88

Reference Data

Efficiency 62.5%

Electronic Ballast

Input Watts (120V) 62.0WBallast Factor .88

Reference Data

Efficiency 65.2%

Electronic Ballast

Input Watts (120V) 62.0WBallast Factor .88

Page 83: LRG CFI

10326

10306 - 120 SO

90

10324

10306 - 120 SO

To complete catalogue no. e.g.:

1

Lightshield

2

Chassis Voltage Ballast

•Sleek wrap-around acrylic diffuser with opaque end caps.•Complete luminaire consists of Lightshield and Chassis. Order each

item separately.•Not suitable for row mounting.

Options pages 150-156Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO.Magnetic Electronic PowerSpec DimmingT8 : OC T8 : SO T8 : PST12 : LE 3 LPB T8 : O3 (not avail. in 347V)

4 LPB T8 : O4LPB : Number of lamps per ballast.T12 not available for 13446 and 13448.

Pendant / SurfaceSurface DecorativeLuminaires

•Linear acrylic trough with no visible trim.•Soft curved form.•Complete luminaire consists of Lightshield and Chassis. Order each

item separately.•Not suitable for row mounting.

Belmont ISurface Wrap Luminaire

Belmont IISurface Wrap Luminaire

2 x 410310 White Chassis (standard)10328 Lightshield16"-W 501/4"-L 3 3/4 "-H4 -T12 / T8

2 x 410310 White Chassis (standard)10330 Lightshield155/8"-W 491/2"-L 3 7/8 "-H4 -T12 / T8

1 x 410306 White Chassis (standard)10324 Lightshield103/4"-W 501/4"-L 3 1/2 "-H2 - T12 / T8

1 x 410306 White Chassis (standard)10326 Lightshield105/8"-W 491/2"-L 3 7/8 "-H2 -T12/T8

To complete catalogue no. e.g.:

1

Lightshield

2

Chassis Voltage Ballast

SURFACE

• T12 options are limited due to new regulations.Please consult factory for their availability.

• Please refer to page 13 for more information regarding the availability of T12 and the New Energy Efficient regulations set forth by National Resources Canada.

Page 84: LRG CFI

10325

10306 - 120 SO

91

13554

13222 - 120 SO

10325

10306 - 120 SO

•Acrylic diffuser with softly contoured edges.•Complete luminaire consists of Lightshield and Chassis. Order each

item separately.•Not suitable for row mounting.

•Frameless acrylic diffuser has no visible hardware, swings down fromeither side for relamping.

•Complete luminaire consists of Lightshield and Chassis. Order eachnumber separately.

Belmont CloudSurface Wrap Luminaire

LumiplexSurface Wrap Luminaire

To complete catalogue no. e.g.:

1

Lightshield

2

Chassis Voltage Ballast

Pendant / Surface

2 x 410310 White Chassis (standard)10327 Lightshield17"-W 511/2"-L 4 "-H4 -T12 / T8

1 x 410306 White Chassis (standard)10325 Lightshield133/4"-W 511/2"-L 4 "-H2 -T12 / T8

2 x 213222 Black Chassis13554 Lightshield26"-W 261/2"-L 3 7/8 "-H2 -T8U6

To complete catalogue no. e.g.:

1

Lightshield

2

Chassis Voltage Ballast

To complete catalogue no. e.g.:

1

Lightshield

2

Chassis Voltage Ballast

Page 85: LRG CFI

92

90°

180° 150° 120°

0° 30°

60°

90°

180° 150° 120°

0° 30°

60°

90°

180° 150° 120°

0° 30°

60°

RCR C. U.1 902 773 674 595 526 467 418 379 3310 30

RCR C. U.1 862 743 654 575 506 457 408 369 3310 30

RCR C. U.1 882 763 664 585 506 457 408 369 3210 29

T5 Staggered Strip Series 26”, 38”, 50” (SS)Surface Staggered Strips

SV4S228UNVPG

SM4S228UNVPG

SS4S5228UNVPG

Features•Only 2” Wide.•Utilizes compact, high efficiency, T5 or T5HO lamps.•Fully enclosed wiring•Optional white or specular, symmetric and assymetric reflector.•Convenience outlet and switch K.O.s provided•Push through lamp holders with rotor for secure lamp retention.•Optional hangers and guards.

Features•Only 1 3/8” deep.•Utilizes compact, high efficiency, T5 or T5HO lamps..•Fully enclosed wiring•Convenience outlet and switch K.O.s provided (1 lamp only)•Push through lamp holders with rotor for secure lamp retention.

Industrial LuminairesT5 Strip Series 22”, 34”, 46”, 92” (SV)Surface Strips

T5 Side-Mount Strip Series 22”, 34”, 46” (SM)Surface Side-Mount Strips

Features•Excellent for applications where continuous, even illumination is

required.

Options pages 150-156Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120PI.Electronic T51 or 2 LPB Program Start: PG1 or 2 LPB Instant Start: PI1 or 2 LPB Power Spec Dimming (120/277V only): PFLPB: Number of lamps per ballast.

OPTIONS/ACCESSORIESStem and canopy sets: Suspend luminaire 12”, 18”, 24”, 36”, or 48” from sur-face. (Two per luminaire is recommended. For 34” and 46” SVB Strip only.)Catalogue number : SV5F12 (12”); SV5F18 (18”); SV5F24 (24”); SV5F36 (36”);SV5F48 (48”)Chain hanging kit: Includes two 5’ heavy duty link chains with sturdy “V” hookfor fixture suspension. (34” and 46” SVB Strip only.) Catalogue number: EE9HCWire guard: Galvanized wire guard. Catalogue number:FOR SV STRIP T5 34”: SV5GXG3FOR SV STRIP T5 46”: SV5GXG4Reflectors: See pages 94-95.Rocker switch: Suffix: H (SV and 1 lamp SM only)Convenience outlet: Suffix: CO (SV and 1 lamp SM only)

2 T5 Sidemount Strip

2 T5 Strip

2 T5 Staggered Strip

STRIPS

Page 86: LRG CFI

93

SV4S228 UNV PG

SM4S228 UNV PG

SS4S228 UNV PG

Reference Data

Efficiency 93.3%Spacing Ratio 1.5

Electronic Ballast

Input Watts (120V) 60.0WBallast Factor 1.0

Reference Data

Efficiency 93.3%Spacing Ratio 1.5

Electronic Ballast

Input Watts (120V) 66.0WBallast Factor 1.0

Reference Data

Efficiency 93.3%Spacing Ratio 1.5

Electronic Ballast

Input Watts (120V) 66.0WBallast Factor 1.0

Application Data*

Luminaire Spacing FC W/Sq Ft

50' x 70' x 8.5' Space

12' on centre 29 .45

30' x 30' x 8.5' Space

10' on centre 36 .66

12' x 16' x 8.5' Space

8' on centre 54 1.4

Type Nominal Number T5 T5HOlength of lamp

STRIP T5 22 1/2” 1 SV2S114 SV2S12422 1/2” 2 SV2S214 SV2S22434 1/4” 1 SV3S121 SV3S13934 1/4” 2 SV3S221 SV3S239

46” 1 SV4S128 SV4S15446” 2 SV4S228 SV4S25492” 2 (tandem) SV8S128 SV8S15492” 4 (tandem) SV8S228 SV8S254

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :Strip T5 UNV (120/277V) See page 92 See page 92

120277347

Type Nominal Number T5 T5HOlength of lamp

Staggered Strip T5 26 1/2” 1 SS2S114 SS2S12426 1/2” 2 SS2S214 SS2S22438 1/4” 1 SS3S121 SS3S13938 1/4” 2 SS3S221 SS3S239

50” 1 SS4S128 SS4S15450” 2 SS4S228 SS4S254

Ordering Guide

Type Nominal Number T5 T5HOlength of lamp

Side-mount Strip T5 22 1/2” 1 SM2S114 SM2S12422 1/2” 2 SM2S214 SM2S22434 1/4” 1 SM3S121 SM3S13934 1/4” 2 SM3S221 SM3S239

46” 1 SM4S128 SM4S15446” 2 SM4S228 SM4S254

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :Side-mount Strip T5 UNV (120/277V) See page 92 See page 92

120277347

Basic catalogue number : Voltage : Ballast : Options :Staggered Strip T5 UNV (120/277V) See page 92 See page 92

120277347

Industrial Luminaires

* Average footcandles mounted total LLF Reflectance 60% ceiling, 50% wall, 20%. Floor T5 rated at 2610 lumens (25°C).

* Please ask your Canlyte Representative about the 90 deg. lamp mounted SM series T5 Luminaire.

Page 87: LRG CFI

94

90°

180° 150° 120°

0° 30°

60°

90°

180° 150° 120°

0° 30°

60°

90°

180° 150° 120°

0° 30°

60°

90°

180° 150° 120°

0° 30°

60°

RCR C. U.1 902 773 674 595 526 467 418 379 3310 30

RCR C. U.1 862 743 654 575 506 457 408 369 3310 30

RCR C. U.1 882 763 664 585 506 457 408 369 3210 29

RCR C. U.1 862 753 654 575 506 457 408 369 3210 29

2 T5 Symmetric White SV5R1W4SSLD / SV4S254UNVPG

1 T5 Asymmetric White SV5R1W4ASLD / SV4S154UNVPG

2 T5 Asymmetric White SV5R1W4ASLD / SV4S254UNVPG

1 T5 Symmetric Silver SV5R1S4SSLD / SV4S154UNVPG

Features•Only 1 3/8” deep.•Installation on regular SV T5 strip, 1 or 2 lamps.•Available in white or high reflectivity specular finish.•Optional micro-perforated or slotted white reflector.

Features•Only 1 3/8” deep.•Installation on regular SV T5 strip, 1 or 2 lamps.•Available in white or high reflectivity specular finish.

Industrial LuminairesSymmetric Reflector T5 22”, 34”, 46”For 1 or 2 lamps T5 Strip (SV)

Asymmetric Reflector T5 22”, 34”, 46”For 1 or 2 lamps T5 Strip (SV)

STRIPS

Page 88: LRG CFI

95

Reference Data

Efficiency 85.8%Spacing Ratio -

Electronic Ballast

Input Watts (120V) 121WBallast Factor 1.0

Type Luminaire Nominal Reflector for T5 Strip*Length

Asymetric Reflector 22 1/2” SV5R1W2ASLDWHITE 34 1/4” SV5R1W3ASLD

46” SV5R1W4ASLD92” 2X SV5R1W4ASLD

Asymetric Reflector 22 1/2” SV5R1S2ASLDSILVER 34 1/4” SV5R1S3ASLD

46” SV5R1S4ASLD92” 2X SV5R1S4ASLD

*Use with 1 or 2 T5 Strip (SV)

Ordering Guide

Reference Data

Efficiency 87,5%Spacing Ratio 1.9

Electronic Ballast

Input Watts (120V) 64WBallast Factor 1.0

Reference Data

Efficiency 78.7%Spacing Ratio 1.4

Electronic Ballast

Input Watts (120V) 121WBallast Factor 1.0

Reference Data

Efficiency 91.8%Spacing Ratio -

Electronic Ballast

Input Watts (120V) 64WBallast Factor 1.1

Application Data*

Luminaire Spacing FC W/Sq Ft

50' x 70' x 8.5' Space

12' on centre 25 .44

30' x 30' x 8.5' Space

10' on centre 31 .64

12' x 16' x 8.5' Space

8' on centre 47 1.3

Lamp rated at 2610 lumens

Application Data*

Luminaire Spacing FC W/Sq Ft

50' x 70' x 8.5' Space

12' on centre 50 .83

30' x 30' x 8.5' Space

10' on centre 51 1.2

12' x 16' x 8.5' Space

8' on centre 84 2.5

Lamp rated at 4400 lumens

Type Luminaire Nominal Reflector for T5 Strip*Length

Symetric Reflector 22 1/2” SV5R1W2SSLD**WHITE 34 1/4” SV5R1W3SSLD**

46” SV5R1W4SSLD**92” 2X SV5R1W4SSLD**

Symetric Reflector 22 1/2” SV5R1S2SSLDSILVER 34 1/4” SV5R1S3SSLD

46” SV5R1S4SSLD92” 2X SV5R1S4SSLD

* Use with 1 or 2 T5 Strip (SV)** For Slotted White Reflector, replace Solid White SLD by SLT** For Microperforated White Reflector, replace Solid White SLD by PER

Ordering Guide

Industrial Luminaires

Type Luminaire Nominal Reflector for T5 Strip*Length

Symetric Reflector 22 1/2” SV5R1W2SSLD**WHITE 34 1/4” SV5R1W3SSLD**

46” SV5R1W4SSLD**92” 2X SV5R1W4SSLD**

Symetric Reflector 22 1/2” SV5R1S2SSLDSILVER 34 1/4” SV5R1S3SSLD

46” SV5R1S4SSLD92” 2X SV5R1S4SSLD

* Use with 1 or 2 T5 Strip (SV)** For Slotted White Reflector, replace Solid White SLD by SLT** For Microperforated White Reflector, replace Solid White SLD by PER

Ordering Guide

Type Luminaire Nominal Reflector for T5 Strip*Length

Asymetric Reflector 22 1/2” SV5R1W2ASLDWHITE 34 1/4” SV5R1W3ASLD

46” SV5R1W4ASLD92” 2X SV5R1W4ASLD

Asymetric Reflector 22 1/2” SV5R1S2ASLDSILVER 34 1/4” SV5R1S3ASLD

46” SV5R1S4ASLD92” 2X SV5R1S4ASLD

*Use with 1 or 2 T5 Strip (SV), see pages 92-93.

Ordering Guide

* Average footcandles mounted total LLF = .90 Reflectance 80% ceiling, 50% wall, 20% Floor T5 rated at (25°C).

Page 89: LRG CFI

90°

180° 150° 120°

0° 30°

60°

2.7"(67 mm)

1-5/8"(41.2 mm)

3"(76.2 mm)

3.75"(95 mm)

2-1/2"(63.5 mm)

4-5/8"(117.4 mm)

3.75"(95 mm)

2-1/2"(63.5 mm)

4-5/8"(117.4 mm)

90°

180° 150° 120°

0° 30°

60°

90°

180° 150° 120°

0° 30°

60°

1-7/8"(48mm)

9-1/4"(235mm)

2-3/4"(70 mm)

2-3/4"(70 mm)

9-1/4"(235mm)

1-7/8"(48mm)

1-5/8"(41mm)

4-1/4"(108mm)

2-3/4"(70 mm)

2-3/4"(70 mm)

4-1/4"(108mm)

1-5/8"(41mm)

96

RCR C. U.1 842 713 624 545 476 427 378 339 3010 27

RCR C. U.1 872 753 654 575 506 447 408 359 3210 29

RCR C. U.1 872 753 654 575 506 447 408 359 3210 29

Wide Strip

Strip HO

Industrial LuminairesSurface Strip SB SeriesNarrow / Wide Strips

Created with the installer in mind, the strip incorporates labor saving andsolid design features. Time saving flip-on end caps and ballast coversinstall quickly. Strengthening ribs ensure uniformity and stability of thechannel housing. It’s quality lighting that will save you time and dollars.

Features•Flip-up end caps and snap-on ballast cover.•2-3/4" wide housing channel (1 lamp).•4-1/4" wide housing channel (1 - 2 lamp).•Fully enclosed wiring.•Screwdriver slot for easy ballast cover removal.•Combination end-cap for continuous row mounting.•Optional hangers, wire guards.•Available with Symmetrical and Asymmetrical reflectors

(order separately) (see pages 98-99).

Options pages 150-156Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO.Magnetic Electronic4' T12: LE 1 or 2 LPB T8: SOSL T12: LE† 3 LPB T8: O3HO T12: LE† 4 LPB T8: O4 (4' lamp only)T8: OC 2 x 3 LPB T8: O6†Available only for 8’.For T12 HO 4’ leave blank.LPB : Number of lamps per ballast. Electrical/Wiring Options For special wiring, fusing, electronicdimming ballasts or emergency packs, consult factory.Optional hangers, wire guards and aligners, see page 155.

SB148-120SO (Data)

SB296H-120LE (Data)

SB296S-120LE (Data)

Narrow Strip

STRIPS

• T12 options are limited due to new regulations.Please consult factory for their availability.

• Please refer to page 13 for more information regarding the availability of T12 and the New Energy Efficient regulations set forth by National Resources Canada.

Page 90: LRG CFI

SB148T 120 SO

SB148H 120

SB248T 120 04

97

( )( )( ) )(

* Average Footcandles Maintained Total LLF = .75 Reflectance: 80% Ceiling, 50% Wall, 20% Floor.

Reference Data

Efficiency 89.5%Spacing Ratio 1.6

Electronic Ballast

Input Watts (120V) 30.0WBallast Factor .88

Reference Data

Efficiency 89.7%Spacing Ratio 1.6

Electronic Ballast

Input Watts (120V) 257.0WBallast Factor .95

Reference Data

Efficiency 89.7%Spacing Ratio 1.6

Electronic Ballast

Input Watts (120V) 160WBallast Factor .96

SL : Slimline

Industrial Luminaires

Application Data*

Luminaire Spacing FC W/Sq Ft

50' x 70' x 8.5' Space

10' on centre 48 1.4

30' x 30' x 8.5' Space

8' on centre 50 1.1

12' x 16' x 8.5' Space

6' on centre 37 1.1

Lamp rated at 3000 lumens

Application Data*

Luminaire Spacing FC W/Sq Ft

50' x 70' x 12' Space

12' on centre 99 2.6

50' x 70' x 12' Space

16' on centre 79 2.2

50' x 70' x 8.5' Space

12' on centre 109 2.6

30' x 30' x 8.5' Space

12' on centre 90 2.6

Lamp rated at 8800 lumens

Application Data*

Luminaire Spacing FC W/Sq Ft

50' x 70' x 12' Space

12' on centre 69 1.6

50' x 70' x 8.5' Space

10' on centre 88 1.9

30' x 30' x 8.5' Space

8' on centre 87 2.1

Lamp rated at 6100 lumens

Type Nominal Lamps Onelength watts/type lamp

Narrow 18" 1-T12 LPF SB118LStrip† 18" 1-T12/T8 SB118

24” 1-T12LPF SB124L24” 1-T12/T8 SB12436” 1-T12/T8 SB13648” 1-T12/T8 SB14872” 2-T12/T8 (tandem) SB136T96” 2-T12/T8 (tandem) SB148T (tandem)

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :Surface Strip 120 See page 96 See page 962 lamps (Tandem) 277

347

Type Nominal Lamps One Two Three Fourlength watts/type lamp lamp lamp lamp

Wide 24" T12/T8 SB1W2 SB224Strip 36" T12/T8 SB1W3 SB236

48" T12/T8 SB1W4 SB248 SB348 SB44896" T12/T8 SB1W4T SB248T SB348T SB448T

2 lamps 4 lamps 6 lamps 8 lampstandem tandem tandem tandem

96" T12 SL/T8 SL SB196S SB296S SB496S

Ordering Guide

Type Nominal Lamps One Twolength watts/type lamp lamp

Deep 48" 1 or 2-T12HO/T8HO SB148H SB248HStrip 96" 1 or 2-T12HO/T8HO SB196H SB296H

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :

Basic catalogue number : Voltage : Ballast : Options :

Page 91: LRG CFI

180° 150°

120°

60°

90°

30°0°

1-7/8"(47.6 mm)

4-1/4" (107.9 mm)

4-3/8"(111 mm)

42" (1067 mm)

48" (1219 mm)

1-7/8"(47.6 mm)

4-1/4" (107.9 mm)

4-3/8"(111 mm)

51" (1295 mm)

48" (1219 mm)

180° 150°

120°

60°

90°

30°0°

1-7/8"(47.6 mm)

2-3/4"(69.8 mm) 180° 150°

120°

60°

90°

30°0°

1-7/8"(47.6 mm)

2-3/4"(69.8 mm)

98

Industrial LuminairesStaggered StripSurface Strips

Features•Full 3" over lap. Eliminates shadows from lamp ends.•Housing only 1-7/8" deep.•Safe-handling metal edges.•Fully enclosed wireway.•Excellent for applications where continuous, even illumination is

required.

Options pages 150-156Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO.Magnetic ElectronicT8: OC 1 or 2 LPB T8: SO

4 LPB T8: O4For T12 lamp see page 151.LPB : Number of lamps per ballast.Consult factory on 2' and 3' length ballast options.Electrical/Wiring Options For special wiring, fusing, electronicdimming ballasts or emergency packs, consult factory.

Features•Four sizes: 18”, 24", 36", 48".•Fully enclosed wiring.•Only 1-7/8" deep.

Options pages 150-156Electrical/Wiring Options For special wiring, fusing, dimming, orelectronic ballasts, consult factory.Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO.Magnetic ElectronicT8: OC 1 or 2 LPB T8: SOFor T12 lamp see page 151.LPB : Number of lamps per ballast. Consult factory on 2' and 3' length ballast options.

Side-Mount StripSurface Strips

STG4132HPF120SO (Data)

STG4232HPF120SO (Data)

CSM4132HPF120SO (Data)

1 lamp

2 Lamp

RCR C. U.1 842 713 624 545 476 427 378 339 3010 27

RCR C. U.1 872 753 654 575 506 447 408 359 3210 29

RCR C. U.1 842 713 624 545 476 427 378 339 3010 27

1 Lamp

2 Lamp

STRIPS

Page 92: LRG CFI

STG4132HPF 120 SO

STG4232HPF 120 SO

CSM4232HPF 120 SO

STG 4 2 32 120 SOHPF

99

Luminaire TypeSTGCSM

Ordering Guide

LuminaireLenght2 = 2’3 = 3’4 = 4’6 = 6’8 = 8’

Number oflamps in aluminaire

cross-section12

Lamp Type17 = T8 2’25 = T8 3’32 = T8 4’20 = T12 2’25 = T12 3’34 = T12 4’

Voltage120277347

OptionsSee pages

98.

HPF BallastOC: Magnetic T8SO: 1 or 2 T8

ElectronicO4: 4 LPB T8

ElectronicLE: Magnetic Energy

Saving

Industrial Luminaires

Type Luminaire Lamp Lamp Cat. numberlength length qty with T8 lamp

Staggered 24" 2' 1-T8 STG2117HPFChannel Strip 36" 3' 1-T8 STG3125HPF(One Lamp 48" 4' 1-T8 STG4132HPFin Width) 69" 3' 2-T8 Tandem STG6125HPF

93" 4' 2-T8 Tandem STG8132HPF

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :Staggered Strip 120 See page 98 See page 981 lamp 277 Add appropriate

347 suffix to cataloguenumber

Type Luminaire Lamp Lamp Cat. numberlength length qty with T8 lamp

Side-Mount Strip 24" – 1-T8 CSM2117HPF(One Lamp) 36" – 1-T8 CSM3125HPF

48" – 1-T8 CSM4132HPFSide-Mount Strip 24" – 2-T8 CSM2217HPF(Two Lamp) 36" – 2-T8 CSM3225HPF

48" – 2-T8 CSM4232HPF

Ordering Guide

Type Luminaire Lamp Lamp Cat. numberlength length qty with T8 lamp

Staggered 27" 2' 2-T8 STG2217HPFChannel Strip 39" 3' 2-T8 STG3225HPF(Two Lamps 51" 4' 2-T8 STG4232HPFin Width) 75" 3' 4-T8 Tandem STG6225HPF

99" 4' 4-T8 Tandem STG8232HPF

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :

Basic catalogue number : Voltage : Ballast : Options :

Reference Data

Efficiency 89.5%Spacing Ratio 1.6

Electronic Ballast

Input Watts (120V) 30.0WBallast Factor .88

Reference Data

Efficiency 89.7%Spacing Ratio 1.6

Electronic Ballast

Input Watts (120V) 62.0WBallast Factor .88

Reference Data

Efficiency 89.5%Spacing Ratio 1.6

Electronic Ballast

Input Watts (120V) 30.0WBallast Factor .88

Page 93: LRG CFI

1500

17000°

600

900

1200

300

0

30°

60°

1500

16500°

600

900

1200

300

0

30°

60°

6"(152 mm)

5"(127 mm)

SB9R1-XX

6-1/2"(165 mm)

6-3/4"(171 mm)

SB9R2-XX

(

5"(127 mm)

3"(76 mm)

7-1/4"(184 mm) SB9R16-XX

6-1/2"(165 mm)

6-3/4"(171 mm)

SB9R2-XXSLT

100

6"(152 mm)

5"(127 mm)

SB9R8-XX

7-1/2"(191 mm)

5"(127 mm)

SB9R6-XX

3"(76 mm)

4-1/4"(108 mm)

SB9R1-XX90XSLT

7-1/2"(191 mm)

5"(127 mm)

SB9R6-XXSLT

Industrial LuminairesSpecular Reflectors

RCR C. U.1 982 883 794 725 646 597 538 489 4410 41

RCR C. U.1 952 823 724 645 566 507 458 419 3710 33

SB9R21S-48 (Reflector) with SB148-120SO (Strip)

SB9R14S-48 (Reflector) with SB248-120SO (Strip)

SB9R21S-48 (Data)Narrow Spacing - Specular Reflector

Wide Spacing - Specular Reflector SB9R14S-48 (Data)

The SB9R specular reflector series provides very high efficiencies and iswell suited for hard-to-light areas such as gymnasiums and aisles, andfor task lighting. Suitable for low or high ceilings, these reflectorsprovide an economical lighting solution.

Features•High specular silver film material with white painted steel back.•Specular reflector mounts on regular SB series strips.

See pages 96-97 (specify strip and reflector part numbers).•For wire guard option consult Factory.•Suitable for continuous row mounting.•Different spacing ratios available (narrow and wide).

xx = Length of luminaire.

WhiteReflector

White reflectors are suited only to Strips (see pages 94-95).These reflectors come in a wide variety of symmetrical and asymmetrical versions.

Compatibility of white reflectors with wide SB1W Strips:Use reflectors for 2 lamps Strips (e.g. SB1W8 Strip will require whitereflector SB9R6-48).

White Reflectors

INDUSTRIALINDUSTRIAL

Page 94: LRG CFI

101

Industrial Luminaires

Reference Data

Efficiency 91.2%Spacing Ratio .7

Reference Data

Efficiency 92.3%Spacing Ratio 1.3

Type Luminaire Lamps Reflector cataloguelength qty/type number

Specular 24” 1 SB9R21S-24Industrial 36” 1 SB9R21S-36Reflector 48” 1 SB9R21S-48

96” 2 (tandem) 2-SB9R21S-48

Ordering Guide

Type Luminaire Lamps Reflector cataloguelength qty/type number

Specular 24” 2 SB9R14S-24Industrial 36” 2 SB9R14S-36Reflector 48” 2 SB9R14S-48

96” 4 (tandem) 2-SB9R14S-48

Ordering Guide

Application Data*

Luminaire Spacing FC W/Sq Ft

50' x 70' x 8.5' Space

8' on centre 71 1.1

30' x 30' x 8.5' Space

8' on centre 69 1.1

12' x 16' x 8.5' Space

6’ on centre 72 1.4

Application Data*

Luminaire Spacing FC W/Sq Ft

50' x 70' x 12' Space

12' on centre 86 1.2

50' x 70' x 8.5' Space

12' on centre 91 1.2

30' x 30' x 8.5' Space

8’ on centre 126 1.9

For use with the wide strip series. See pages 96-97.

For use with the narrow strip series. See pages 96-97.

Ordering GuideWhite Reflector

*Average Footcandles Maintained Total LLF= .75 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 2900 lumens.

Length Lamp Reflectorqty/type catalogue No.

24” 1 SB9R1-2424” 1 SB9R2-2424” 1 SB9R16-2424” 1 SB9R1-24-9024” 1 SB9R2-24-SLT24” 2 SB9R6-2424” 2 SB9R8-2424” 2 SB9R6-24-SLT

Length Lamp Reflectorqty/type catalogue No.

36” 1 SB9R1-3636” 1 SB9R2-3636” 1 SB9R16-3636” 1 SB9R1-36-9036” 1 SB9R1-36-SLT36” 2 SB9R6-3636” 2 SB9R8-3636” 2 SB9R6-36-SLT

Length Lamp Reflectorqty/type catalogue No.

48” 1 SB9R1-4848” 1 SB9R2-4848” 1 SB9R16-4848” 1 SB9R1-48-9048” 1 SB9R2-48-SLT48” 2 SB9R6-4848” 2 SB9R8-4848” 2 SB9R6-48-SLT

Length Lamp Reflectorqty/type catalogue No.

96” 2 tandem SB9R1-48 X296” 2 tandem SB9R2-48 X296” 2 tandem SB9R16-48 X296” 2 tandem SB9R1-48-90 X296” 2 tandem SB9R2-48-SLT X296” 4 tandem SB9R6-48 X296” 4 tandem SB9R8-48 X296” 4 tandem SB9R6-48-SLT X296” 1 or 2-SLHO SB9R6-96S†

96” 1 or 2-SLHO SB9R8-96S†

96” 1 or 2-SLHO SB9R6-96S-SLT†

† Note: On 8-foot Slimline Reflector the PartNumber comes in a kit with 2 x 4-footReflector and centre Brackets.

Page 95: LRG CFI

102

8000

4000

0

30°

60°

17’’

8-3/4’’

17’’

17’’

13-3/8’’

8-3/4’’

2-3/4’’

49-1

/2’’

36’’

98-1

/4’’

36’’

36’’

Designed for Trade (commercial spaces), Recreational and Industriallocations, TriLyte provides much needed versatility in lowbay applications. Using the appropriate lamp, wattage and reflector options,this narrow-body version is also suitable for highbay lighting, particularly retail outlets and indoor sports facilities. Its low-profilehousing (almost 1" shallower than most competing models) is perfect forareas that place a premium on luminaire appearance. Dual-circuitTriLyte equipped with optional motion sensor delivers added lightingcontrol flexibility for industrial applications.

Features•Sturdy one-piece post-painted housing providing clean, smooth,

installation-friendly corners.•Side-mounted ballast for low 2-3/4" profile.•Mounting heights from 12' to 45' with suitable lamping-reflector-

lens selection.•2-, 3- and 4-lamp versions (cross-section view).•Available in 4' and 8' lengths. •Choice of contoured specular, flat specular or flat white reflector.•Contoured specular reflector offers optimum performance and 95%

reflectivity (not available on 2-lamp model).•Choice of stem, surface or chain mounting. •Accepts emergency battery packs.•Available motion sensor allows for total lighting control, added

energy savings (see page 155).

Options pages 150-156Ballast Specify voltage (120, 277, UNV, 347) and add suffix, e.g. 120PU.O4 = T8 Elect. One 4-lamp I.S. THD<20%.O5 = T8 Elect. One 4-lamp and one 2-lamp I.S. THD<20%.O7 = T8 Elect. I.S. One 4-lamp to operate outside lamps.

One 4-lamp to operate inside lamps. THD<20%.PI = T5 Elect. I.S. One 2-lamp. THD<10%.PG =T5HO Elect. P.S. One 2-lamp. THD<10%.PU =T5HO Elect. P.S. One 3-lamp. THD<10%.PV = T5HO Elect. P.S. One 4-lamp. THD<10%.P6 = T5HO Elect. P.S. One 4-lamp ballast to operate outside lamps.

One 2-lamp ballast to operate inside lamps. THD<10%.P7 = T5HO Elect P.S. One 3-lamp ballast to operate lamps 1, 3 and 5.

One 3-lamp ballast to operate lamps 2, 4 and 6. THD<10%.P8 = T5HO Elect. P.S. One 4-lamp to operate outside lamps.

One 4-lamp to operate inside lamps. THD<10%.Consult your Canlyte representative for other ballast options. Wireguard/Lens Variety of shielding options available (see photosopposite).Internaal Fusing Suffix F.Electrical/Wiring Options Consult your Canlyte representative.Stem and Canopy Sets 4 stems required per luminaire. Order catalogue number STKF12 (12"), STKF18 (18"), STKF24 (24"),STKF36 (36"), STKF448 (48").Chain Hanger Kit 2 kits required per luminaire. Order catalogue number EE9HC.Luminaire-Mounted Motion Sensor 360° coverage. Field installed.Only available on luminaires with contoured specular reflectors. Order catalogue number FH360-120 / FM360-277 / FH360-347.Reemote-Mounted Motion Sensor Narrow coverage. Field installed.Order catalogue number FH110. Used with PowerPack, order cataloguenumber FHP20-120* (120V)/ FMP20-277 (277V)/ FHP20-347 (347V).* See factory for specifications

VA: Pattern 12 prismatic lensmade of virgin acrylic (.095"nominal). Complete withhinged white wireguard.

VB: Pattern 12 prismatic lensmade of virgin acrylic (.125"nominal). Complete withhinged white wireguard.

WW: White hinged wireguardonly (no lens), 9-gauge wireadding rigidity to luminaire.

XX: Version without lens shielding.

Narrow-Body 4’ Narrow-Body 8’

RCR CU1 962 883 824 765 706 667 608 569 5210 48

FH4C4DXX454120CV (Data)

Industrial Luminaire

TriLyteNarrow-Body 2-, 3-, 4-Lamp Lowbay Surface/Pendant Luminaire

INDUSTRIAL

xx = Luminaire Length.xx = Luminaire Length.

Page 96: LRG CFI

103

FFH4W4DWW454 UNV PV

FH 4 W 4 D WW 4 54 UNV PV

* Average Footcandles Maintained. Total LLF = 0.84. Reflectance: 80% Ceiling, 50% Wall, 20% Floor. 54W T5HO lamp rated at 4400 lumens at 25oC.

LLuminaireTypeFH: TriLyte

LuminaireLength4: 4’8: 8’

Body StyleW : Flat DesignWhite ReflectorC : ContouredSpecularReflectorS : Flat DesignSpecularReflector

Width4: 17’’

TypeD: Downlight

Lens/ShhieldingVA: Prismatic LensVA with Wireguard VB: Prismatic LensVB with Wireguard WW: Wireguard,White /No LensXX: No Shielding

LampQuantity in aluminairecross-section2: 2 lamps3: 3 lamps4: 4 lamps

Lamp/Type228: T5 28W 32: T8 32W54: T5HO 54W

Voltage120277

UNV347

BallastO4 = T8 Elect. One 4-lamp I.S. THD<20%O5 = T8 Elect. One 4-lamp and one 2-lamp I.S.THD<20%O7 =T8 Elect. I.S. One 4-lamp/outside lamps. One 4-lamp/inside lamps. THD<20%.PI = T5 Elect. I.S. One 2-lamp I.S., THD<10%PG = T5HO Elect. P.S. One 2-lamp, THD<10%PU = T5HO Elect. P.S. One 3-lamp, THD<10%PV = T5HO Elect. P.S. One 4-lamp, THD<10%P6 = T5HO Elect. P.S. One 4-lamp/outside lamps.One 2-lamp/inside lamps. THD<10%P7 = T5HO Elect P.S. One 3-lamp ballast for lamps 1,3 and 5, One 3-lamp ballast for lamps 2, 4 and 6,THD<10%P8 = T5HO Elect. P.S. One 4-lamp/outside lamps.One 4-lamp/inside lamps. THD<10%

Numbering Logic

OptionsAdd appropriate suffixto catalogue numbersee pages 150-156

CU: Coefficients of UtilizationFC: FootcandlesIS: Instant StartLLF: Light Loss FactorPS: Program StartRCR: Room Cavity RatioTHD: Total Harmonic Distortion

Acronyms Used

Application Data*

Luminaire Spacing FC W/Sq Ft

300' x 400' x 25' Space17’ on centre 50 0.81

120' x 80' x 28' Space16’ on centre 55 0.98

300' x 400' x 25' Space14’ on centre 75 1.15

Type Lamps Lamp/Luminaire Luminaire Catalogueqty/type Nominal Length width number

Prismatic 2-T5HO 48" 17" FH4W4DVB254Lens (VB) 3-T5HO 48" 17" FH4C4DVB354With 4-T5HO 48" 17" FH4C4DVB454Wireguard 6-T5HO 96" tandem 17" FH8C4DVB354

8-T5HO 96" tandem 17" FH8C4DVB454

White 2-T5HO 48" 17" FH4W4DWW254Wireguard 3-T5HO 48" 17" FH4C4DWW354With 4-T5HO 48" 17" FH4C4DWWW454No Lens 6-T5HO 96" tandem 17" FH8C4DWW354

8-T5HO 96" tandem 17" FH8C4DWW454

Ordering Guide - T5

Type Lamps Lamp/Luminaire Luminaire Catalogueqty/type Nominal Length width number

Prismatic 2-T8 48" 17" FH4W4DVB232Lens (VB) 3-T8 48" 17" FH4C4DVB332With 4-T8 48" 17" FH4C4DVB432Wireguard 6-T8 96" tandem 17" FH8C4DVB332

8-T8 96" tandem 17" FH8C4DVB432

White 2-T8 48" 17" FH4W4DWW232Wireguard 3-T8 48" 17" FH4C4DWW332With 4-T8 48" 17" FH4C4DWWW432No Lens 6-T8 96" tandem 17" FH8C4DWW332

8-T8 96" tandem 17" FH8C4DWW432

Ordering Guide - T8

Basic catalogue number: Voltage: Ballast: Options:TriLyte 120 See below. See belowLuminaire 277 Add appropriate

347 suffix to cataloguenumber

Reference Data

Efficiency 86.2%Spacing Ratio 1.2

Electronic Ballast

Input Watts (120V) 234WBallast Factor 1.00

Industrial Luminaires

Luminaire-Mounted Motion Sensor360° coverage. Field installed. Catalogue Number FH360-120 / FH360-277 / FH360-347.

Remote-MountedMotion Sensor.Narrow coverage. field installed. CatalogueNumber FH110. This sensor is sold in conjunction with a Power pack # FHP20-120 (120 V),FHP20-277 (277 V) orFHP20-347 (347 V),please order accordingly.

Page 97: LRG CFI

104

6000

4000

0

30°

60°

23-1/8’’

23-1/8’’

19-5/8’’

15’’

2-3/4’’

49-1

/2’’

36’’

RCR CU1 1002 923 854 795 726 677 628 589 5310 49

Wide-Body 4’

FH4C5DXX654UNVPG (Data)

Designed for Trade (commercial spaces), Recreational and Industriallocations, TriLyte provides much needed versatility in highbay applications. Using the appropriate lamp, wattage and reflector options,this wide-body version is also suitable for lowbay lighting, particularlyretail outlets and indoor sports facilities. Its low-profile housing (almost1" shallower than most competing models) is perfect for areas thatplace a premium on luminaire appearance. Dual-circuit TriLyte equippedwith optional motion sensor delivers added lighting control flexibility forindustrial applications.

Features•Sturdy one-piece post-painted housing providing clean, smooth,

installation-friendly corners.•Side-mounted ballast for low 2-3/4" profile.•Mounting heights up to 45'.•6-lamp versions only (cross-section view).•Available in 4' lengths only. •Choice of contoured specular or flat white reflector.•Contoured specular reflector offers optimum performance and 95%

reflectivity.•Choice of stem, surface or chain mounting. •Accepts emergency battery packs.•Available motion sensor allows for total lighting control,

added energy savings (see page 155).

Options pages 150-156Ballast Specify voltage (120, 277, UNV, 347) and add suffix, e.g. 120P6.O5 = T8 Elect. One 4-lamp and one 2-lamp I.S. THD<20%.P6 = T5HO Elect. P.S. One 4-lamp ballast to operate outside lamps.

One 2-lamp ballast to operate inside lamps. THD<10%.P7 = T5HO Elect P.S. One 3-lamp ballast to operate lamps

1, 3 and 5. One 3-lamp ballast to operate lamps 2, 4 and 6. THD<10%.

Consult your Canlyte representative for other ballast options. Wireguard/Lens Variety of shielding options available (see photosopposite).Internal Fusing Suffix F.Electrical/Wiring Options Consult your Canlyte representative.Stem and Canopy Sets 4 stems required per luminaire. Order catalogue number STKF12 (12"), STKF18 (18"), STKF24 (24"),STKF36 (36"), STKF48 (48").Chain Hanger Kit 2 kits required per luminaire. Order catalogue number EE9HC.Luuminaire-Mounted Motion Sensor 360° coverage. Field installed. Only available on luminaires with contoured specular reflectors. Order catalogue number FH360-120 / FH360-277 / FH360-347.Remote-Mounted Motion Sensor Narrow coverage. Field installed.Order catalogue number FH110. Used with PowerPack, order cataloguenumber FHP20-120* (120V)/ FMP20-277 (277V)/ FHP20-347 (347V).* See factory for specifications

VA: Pattern 12 prismatic lensmade of virgin acrylic (.095"nominal). Complete withhinged white wireguard.

VB: Pattern 12 prismatic lensmade of virgin acrylic (.125"nominal). Complete withhinged white wireguard.

WW: White hinged wireguardonly (no lens), 9-gauge wireadding rigidity to luminaire.

XX: Version without lens shielding.

Industrial Luminaire

TriLyteWide-Body 6-Lamp Highbay Surface/Pendant Luminaire

INDUSTRIAL

xx = Luminaire Length.

Page 98: LRG CFI

105

FFH4W5DWW654 UNV P6

FH 4 W 5 D WW 6 54 UNV P6

LLuminaire TypeFH : TriLyte

LuminaireLength4: 4’

Body StyleW: Flat DesignWhite ReflectorC: ContouredSpecularReflectorS: Flat DesignSpecularReflector

Width5: 23”

TypeD: Downlight

Lens/ShieldinngVA: Prismatic LensVA with Wireguard VB: Prismatic LensVB with Wireguard WW: Wireguard,White/No LensXX: No Shielding

LampQuantity in aluminairecross-section6: 6 lamps

Lamp/Type28: T5 28W32: T8 32W 54: T5HO 54W

VVoltage120277

UNV347

BallastO5 = One 4-lamp and one 2-lamp I.S. THD<20%P6 = T5HO Elect. P.S. One 4-lamp/outsidelamps. One 2-lamp/inside lamps. THD<10%P7 = T5HO Elect P.S. One 3-lamp ballast forlamps 1, 3 and 5, One 3-lamp ballast for lamps2, 4 and 6, THD<10%

Numbering Logic

OptionsAdd appropriatesuffix to cataloguenumbersee pages 150-156

CU: Coefficients of UtilizationFC: FootcandlesIS: Instant StartLLF: Light Loss FactorPS: Program StartRCR: Room Cavity RatioTHD: Total Harmonic Distortion

Acronyms Used

Type Lamps Lamp/Luminaire Luminaire Catalogueqty/type Nominal Length width number

Prismatic Lens(VB) with 6-T5HO 48" 23" FH4C5DVB654UNVP6Wireguard

White Wireguard 6-T5HO 48" 23" FH4C5DWW654UNVP6with no Lens

Ordering Guide - T5

Type Lamps Lamp/Luminaire Luminaire Catalogueqty/type Nominal Length width number

Prismatic Lens (VB) with 6-T8 48" 23" FH4C5DVB632120O6Wireguard

White Wireguard 6-T8 48" 23" FH4C5DWW632120O6with no Lens

Ordering Guide - T8

Basic catalogue number: Voltage: Ballast: Options:TriLyte 120 See below. See belowLuminaire 277 Add appropriate

347 suffix to cataloguenumber

* Average Footcandles Maintained. Total LLF = 0.84. Reflectance: 80% Ceiling, 50% Wall, 20% Floor. 54W T5HO lamp rated at 4400 lumens at 25oC.

Application Data*

Luminaire Spacing FC W/Sq Ft

120' x 80' x 28' Space240 sq ft per lum. 80 1.5

120' x 80' x 28' Space20' on centre 50 1.9

300' x 400' x 25' Space18' on centre 75 1.1

300' x 400' x 25' Space**22' on centre 50 0.76

Reference Data

Efficiency 90.0%Spacing Ratio 1.2

Electronic Ballast

Input Watts (120V) 358WBallast Factor 1.00

Industrial Luminaires

Luminaire-MountedMotion Sensor360° coverage. Field installed. Catalogue Number FH360-120 / FH360-277/ FH360-347.

Remote-MountedMotion SensorNarrow coverage. field installed. CatalogueNumber FH110. This sensor is sold in con-junction with a Power pack #FHP20-120 (120 V),FHP20-277 (277 V) orFHP20-347 (347 V),please order accordingly.

Page 99: LRG CFI

1510

1000

500

0

30°

60°

6-1/4"(158.7 mm)

13" (330.2 mm)

4-5/8" (117.4 mm)

6-1/4"(158.7 mm)

13" (330.2 mm)

4-5/8" (117.4 mm)

1554

1000

500

0

30°

60°

106

• T12 options are limited due to new regulations.Please consult factory for their availability.

• Please refer to page 13 for more information regarding the availability of T12 and the New Energy Efficient regulations set forth by National Resources Canada.

Industrial LuminairesIndustrial 4’, 8’ (EE, FF)Open Industrial Luminaires

Features•Reflector is embossed for rigidity.•Reflector sides are turned up for rigidity.•Solid top reflector, EE series.•10% aperture reflector, FF series.•Fully enclosed wiring.

EE248-120SO (Data)

TU248-120SO (Data)

Options pages 150-156Ballast Specify voltage (120, 277, 347) and add suffix (e.g. EE248-120SO) E.S. Magnetic Electronic One-3 Lamp Electronic One-4 Lamp ElectronicRS T12: LESL T12: LE†

HO T12: LE†

T8: OC T8: SO 3 LPB T8: O3 4 LPB T8: O4LPB : Number of lamps per ballast.†Available only for 8’. For T12 HO 4’ leave blank.Cold Weather Ballasts HO standard with -17°F (-27°C) ballasts. For RS type luminairesadd suffix SC (T8 electronic) CW (T12 magnetic), to Catalogue Number.Slide Grip Hanger (HO, only) Accepts 1/2" thread stems or rods. Slides into luminairechassis grooves. Order catalogue number EE9H3.Chain Hanger Kit Order catalogue number EE9HC.4' Wire Guard Order two per 8' luminaire. Order catalogue number EE9G4.Reflector Row Aligner For continuous row installations. Order catalogue number EE9RA.Hard Surface Mounting or Twist Tee For 4-1/2" deep channel, catalogue number EE9H1.

Options pages 150-156Ballast Specify voltage (120, 277 347) and add suffix, (e.g. TU248-120SO)Magnetic Electronic One-3 Lamp Electronic One-4 Lamp ElectronicRS T12: LE T5/T5HO: PG T5HO: PU T5HO: PVSL T12: LE†

HO T12: LE†

T8: OC T8: SO 3 LPB T8: O3 4 LPB T8: O4LPB : Number of lamps per ballast.†Available only for 8’. For T12 HO 4’ leave blank.Cold Weather Ballasts HO standard with -17°F (-27°C) ballasts. For RS type luminairesadd suffix SC (T8 electronic) CW (T12 magnetic), to catalogue number.Housing Row Couplers For continuous row mounting (stem/chain). One per joint required.Order catalogue number TU9PLC.Slide-Grip Hangers Accepts 1/2” thread stems or rods. Slides into luminaire chassisgrooves. Order catalogue number EE9H3.Chain Hanger Kit Order catalogue number EE9HC.4’ Wire Guard Order catalogue number TU9G4.Reflector: Use suffix SD for solid reflector. Silver Reflector consult factory.Shielding: Lens TU9LN4 Louver: TU9LV4End Plate Set: Order 1 set for continuous row mount or in conjuction with shielding appli-cations TU9END.

Features• Rugged telescoping turret lampholders.• Optimum 6" lamp spacing (2 lamp).• Reflector is embossed for rigidity.• Reflector sides are turned up for rigidity and safe handling.• 15% aperture reflector, standard.• Solid top reflector, optional.• Reflector secured to housing with easy to use thumb screws.• 4-5/8" wide channel type housing.• Fully enclosed wiring.• Reflector row aligner included.• Reflector post painted with 89% reflectance white polyester paint.• Optional silver reflector.• Optional louver or lens shielding.• Available in T5 and T8 lamp options.

Turret Open T8 / T5 Industrial 4’, 8’ (TU)Premium Open Industrial

RCR C. U.1 922 803 704 625 536 487 438 389 3410 31

RCR C. U.1 912 793 704 625 556 497 448 399 3510 32

INDUSTRIAL

Page 100: LRG CFI

FF296H 120 LE

TU296H 120 LE

107

Industrial Luminaires

Application Data*

Luminaire Spacing FC W/Sq Ft

50' x 70' x 12' Space

12' on centre 78 1.2

50' x 70' x 8.5' Space

10' on centre 100 1.3

50' x 70' x 8.5' Space

12' on centre 86 1.2

30' x 30' x 8.5' Space

12' on centre 84 1.4

Application Data*

Luminaire Spacing FC W/Sq Ft

50' x 70' x 12' Space

16' on centre 60 0.9

50' x 70' x 12' Space

12' on centre 76 1.2

50' x 70' x 8.5' Space

10' on centre 97 1.3

30' x 30' x 8.5' Space

12' on centre 83 1.4

Type Lum. lgth. Lamps Lamp Lamp Cataloguenominal in width type length number

Solid Top 48" 1 1 x T12/T8 48" EE148reflector 48" 2 2 x T12/T8 48" EE248

96" 1 2 x T12/T8 96" EE148T96" 2 4 x T12/T8 96" EE248T48" 3 3 x T12/T8 48" EE34896" 3 6 x T12/T8 96" EE348T48" 2 2 x HO 48" EE248H96" 1 1 x SL 96" EE196S96" 2 2 x SL 96" EE296S

10% Uplight 96" 1 1 x HO 96" FF196HReflector 96" 2 2 x HO 96" FF296H

48" 1 1 x T12/T8 48" FF14848" 2 2 x T12/T8 48" FF24896" 1 2 x T12/T8 96" FF148T96" 2 4 x T12/T8 96" FF248T48" 3 3 x T12/T8 48" FF34896" 3 6 x T12/T8 96" FF348T48" 2 2 x HO 48" FF248H96" 1 1 x SL 96" FF196S96" 2 2 x SL 96" FF296S96" 1 1 x HO 96" FF196H96" 2 2 x HO 96" FF296H

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :Open Industrial 120 For options For options

277 consult consult347 page 106 page 106

*Average Footcandles Maintained. Total LLF=BF (1.0) x .85 = .85 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens.

Reference Data

Efficiency 88.4%Spacing Ratio 1.5

Electronic Ballast

Input Watts (120V) 62.0WBallast Factor .88

Reference Data

Efficiency 89.2%Spacing Ratio 1.3

Electronic Ballast

Input Watts (120V) 62.0WBallast Factor .88

Type Lum. lgth. Lamps Lamp Lamp Catalognominal in width type length number

15% Uplight 48" 2 2x T5 46" TU228Flat 96" 2 4x T5 46" TU228TReflector 48" 2 2X T12/T8 48" TU248

96" 2 4X T12/T8 48" TU248T48" 3 3X T12/T8 48" TU34896" 3 6X T12/T8 48" TU348T48" 4 4X T12/T8 48" TU44848" 2 2X T5HO 46" TU25496" 2 4x T5HO 46" TU254T48" 3 2x T5 46" TU32848" 3 2X T5HO 46" TU35448" 4 2x T5 46" TU42848" 4 2X T5HO 46" TU454

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :Premium Turret Industrial 120 For options For options

277 consult consult347 page 106 page 106

Heavy Duty Slide-Grip HangerEE9H3.

Chain Hanger Kit EE9HC.Two 24” heavy duty link chain.

Page 101: LRG CFI

108

1517

1000

500

0

30°

60°

90°

7"(178mm)

5"(127mm)

(1265mm)47 13/16"

(2484mm)97 13/16"

1517

1000

500

0

30°

60°

90°

7 5/8"(194mm)

5 5/8""(143mm)

7 5/8"(194mm)

4 1/2"(114mm)

(1321mm)49"

(2591mm)102"

(2484mm)

SL97 13/16"

VT248-120SO (Data)

RCR C. U.1 642 553 494 435 386 347 308 279 2410 22

VTS248-120SO (Data)

Options pages 150-156Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO.Magnetic ElectronicT8: OC 1 or 2 LPB T8: SOT12: LE 4 LPB T8: O4

40W TT5: SBLPB : Number of lamps per ballast.Cold Weather Ballasts add suffix SC (T8 electronic) CW (T12 magnetic), tocatalogue number.Water Tight Kit Hub kit for top or end conduit entry. Order suffix: WHP0001.Electrical/Wiring Options For special wiring, fusing: consult factory.Lens: Smooth virgin acrylic with crepe pattern inner surface lens is standard.For polycarbonate lens use suffix VX.Latch: For tamper proof latch use suffix 9.Silver Reflector Use Suffix: X.

RCR C. U.1 642 553 494 435 386 347 308 279 2410 22

Options pages 150-156Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO.Magnetic ElectronicT8: OC 1 or 2 LPB T8: SOT12: LE† 4 LPB T8: O4LPB : Number of lamps per ballast.† Not available for T12 HO 4’, leave blank for a standard ballast.Cold Weather Ballasts HO standard with -17°F (-27°C) ballasts. ForRS type luminaires add suffix SC (T8 electronic) CW (T12 magnetic), to catalogue number for 0°F (-17°C) ballasts.Water Tight Kits Hub kit for top or end conduit entry. Order suffix: WHP0001.Electrical/Wiring Options For special wiring, fusing: consult factory.Lens: Smooth virgin acrylic with crepe pattern inner surface lens is standardfor opal lens add (SW), for high impact lens (DR). For polycarbonate lens usesuffix VX.Latch: For tamper proof latch use suffix 9.Silver Reflector Use Suffix: X.

Sealatron Plus 2’, 4’, 8’ (VTS)Damp / Wet Locations EnclosedClass III

Special Applications LuminairesSealatron 4’, 8’ (VT, VTN)Damp / Wet Locations Enclosed

Features•CSA listed for damp/wet locations.•One-piece fiberglass reinforced polyester housing.•Smooth virgin acrylic lens.•Crepe pattern inner surface lens.•Bonded closed-cell neoprene gasket.•Molded cam-action tension latches.•RS version is 4-1/2" deep. SL and HO are 5-5/8" deep.•Optional polycarbonate lens.•Optional tamper proof latch.•Optional inside silver reflector.•Up to 86% efficient with silver reflector.

Features• CSA listed for damp/wet locations.• CSA listed for Class III, Hazardous location (see page 112).• One-piece fiberglass reinforced polyester housing.• Smooth virgin acrylic lens.• Crepe pattern inner surface lens.• Bonded closed-cell neoprene gasket.• Molded cam-action tension latches.• Optional polycarbonate lens.• Optional tamper proof latch.• Optional inside silver reflector.• Up to 86% efficient with silver reflector.• Water tight kits included (one kit).• No holes are required for mounting, protecting the integrity of the housing.• Galvanized mounting brackets included (2 per luminaire).• Brass mounting studs.• N/A in HO.• IP65 rated.

SPECIALAPPLICATIONS

VT

VTS

• T12 options are limited due to new regulations.Please consult factory for their availability.

• Please refer to page 13 for more information regarding the availability of T12 and the New Energy Efficient regulations set forth byNational Resources Canada.

• T12 options are limited due to new regulations.Please consult factory for their availability.

• Please refer to page 13 for more information regarding the availability of T12 and the New Energy Efficient regulations set forth byNational Resources Canada.

Page 102: LRG CFI

109

VT248 120 SO

VTS248T 120 04

Special Purpose Luminaires

*Average Footcandles Maintained Total LLF=.75 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens.

Type Luminaire Lamps Lamp Lamp Cataloguelength in width type length number

Damp and 49 13/16" 1 T12/T8 48" VTN4132STWet 97 13/16" 1 T12/T8 48" VTN8132STLocations (2 Lamps in

Tandem)

49 13/16" 2 T12/T8 48" VTN4232ST97 13/16" 2 T12/T8 48" VTN8232ST

(4 Lamps inTandem)

97 13/16" 2 SL 96" VTN8275ST52" 1 HO 48" VT148H102" 1 HO 96" VT196H52" 2 HO 48" VT248H102" 2 HO 96" VT296H

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :120 See page 108 See page 108277 Add appropriate347 suffix to catalogue

number

Reference Data

Efficiency 64.6%Spacing Ratio 1.5

Electronic Ballast

Input Watts (120V) 62.0WBallast Factor .88

Application Data*

Luminaire Spacing FC W/Sq Ft

50' x 70' x 12' Space

12' on centre 58 1.9

30' x 30' x 8.5' Space

10' on centre 68 1.4

12' x 16' x 8.5' Space

8' on centre 67 1.9

Precision molded pre-formed knockoutsfor stem, chain or surface mounting.

Smooth virgin acrylic lens opens easilyand hinges from either side for easymaintenance.

Type Luminaire Lamps Lamp Lamp Cataloguelength in width type length number

Damp and 25-13/16" 1 TT5 24" VTS1FTWet 25-13/16" 2 T12/T8 24" VTS224Locations 49-13/16" 1 T12/T8 48" VTS148Class III 97-13/16" 1 T12/T8 48" VTS148T

(2 Lamps inTandem)

49-13/16" 2 T12/T8 48" VTS24897-13/16" 2 T12/T8 48" VTS248T

(4 Lamps inTandem)

Ordering GuideReference Data

Efficiency 64.6%Spacing Ratio 1.5

Electronic Ballast

Input Watts (120V) 62.0WBallast Factor .88

Application Data*

Luminaire Spacing FC W/Sq Ft

50' x 70' x 12' Space

12' on centre 58 1.9

30' x 30' x 8.5' Space

10' on centre 68 1.4

12' x 16' x 8.5' Space

8' on centre 67 1.9

Basic catalogue number : Voltage : Ballast : Options :

Page 103: LRG CFI

1704

1000

500

0

30°

60°

2-13/16"(71.4mm)

8-5/32" (207.1mm)

6-1/16"(26.9mm)

2-13/16"(71.4mm)

8-5/32" (207.1mm)

6-1/16"(26.9mm)

90°

800

400

0

30°

60°

110

RVSIFFSVB232120SO (Data)

RCR C. U.1 662 593 534 485 436 397 358 329 2910 26

SW4C232120SO (Data)

RCR C. U.1 792 673 594 525 456 407 368 329 2910 26

Special Applications LuminairesCleanlite 4’ (SW)Damp / Wet Locations Enclosed Surface Luminaire

1’ x 4’, 2’ x 4’ recessed fluorescent - static with gasket1, 2, 3 and 4 T8 lamps

Features•61.6% efficient.•Neoprene gasket all around.•Full flush steel hinged lens frame.•Lens frame held with screws.•Twin knockout access plate.•Optional tamper-proof screws (consult Factory).•Snap-in ballast cover. •CSA certified for wet location.

Options pages 150-156Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO.Magnetic Electronic PowerSpec DimmingT8: OC 1 or 2 LPB T8: SO T8: PS

3 LPB T8: O3 (not avail. in 347V)4 LPB T8: O4

For T12 lamp see page 151.LPB : Number of lamps per ballast.Special Lenses VB prismatic lens standard. (Prismatic .125” nominal, pattern12). Replace VB by VX for polycarbonate .125” nominal, pattern 12.Example: RVS1FFSVX232120SO.Electrical/Wiring Options Consult factory.Fusing Suffix: F.Radio Interference Filter 120 or 347 volt, 50 or 60 Hz. Suffix R.

General Wet Location 1’x 4’, 2’x 2’, 2’x 4’ (RVS) Recessed Gasketed Luminaire

Features•CSA certified for damp or wet locations.•20 gauge steel chassis.•Smooth one-piece water-clear lens.•Lock-tight cam-action latches.•4' one-piece bodies.•Convenient 8" width.•Optional water tight hubs for electrical feed (SW).•Foam gasketing at all lens seal points.

Options pages 150-156Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO.Magnetic ElectronicT8: OC 1 or 2 LPB T8: SOT12: LE† 4 LPB T8: O4LPB : Number of lamps per ballast.† Not available for T12 HO 4’, leave blank for a standard ballast.Tamper-Proof Latches Zinc cam-latches with spanner head screws. AddSuffix 9 to catalogue number.Water Tight Kits For SW type luminaires only. Hub kit for top or end conduitentry. One kit supplied with luminaires. Order catalogue number: GWHB001.Lens Smooth one-piece water-clear lens is standard. For high impact acryliclens, suffix (DR). For opal lens, add (SW). For lexan (SR).Cold Weather Ballasts HO standard with -17°F (-27°C) ballasts. ForRS type luminaires add suffix SR (T8 electronic) CW (T12 magnetic), to catalogue number.

SPECIALAPPLICATIONS

• T12 options are limited due to new regulations.Please consult factory for their availability.

• Please refer to page 13 for more information regarding the availability of T12 and the New Energy Efficient regulations set forth byNational Resources Canada.

• T12 options are limited due to new regulations.Please consult factory for their availability.

• Please refer to page 13 for more information regarding the availability of T12 and the New Energy Efficient regulations set forth byNational Resources Canada.

Page 104: LRG CFI

RVS2GFSVB432 120 04

SW 4 2 32 120 SOC

111

Special Applications Luminaires

Application Data*

Luminaire Spacing FC W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 51 .9

8' x 10' (80 sq ft/luminaire) 40 .7

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 46 1.1

Type Luminaire Lamps Flanged for Exposedsize qty /type dry or plaster T-Grid

Clean Room 1 x 4 1-T8 RVS1FFSVB132 RVS1GFSVB132Recessed Static 1 x 4 2-T8 RVS1FFSVB232 RVS1GFSVB232

2 x 2 2-T8U6 RVS2FFSVB26U RVS2GFSVB26U2 x 4 2-T8 RVS2FFSVB232 RVS2GFSVB2322 x 4 3-T8 RVS2FFSVB332 RVS2GFSVB3322 x 4 4-T8 RVS2FFSVB432 RVS2GFSVB432

Ordering Guide

*Average Footcandles Maintained. Total LLF=BF (1.0) x .85 = .85 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens.

Basic catalogue number : Voltage : Ballast : Options :

Reference Data

Efficiency 61.6%Spacing Ratio 1.2

Electronic Ballast

Input Watts (120V) 62.0WBallast Factor .88

Application Data*

Luminaire Spacing FC W/Sq Ft

50' x 70' x 8.5' Space

12' on centre 65 1.2

30' x 30' x 8.5' Space

10' on centre 76 1.4

12' x 16' x 8.5' Space

8' on centre 73 1.9

Type Luminaire Lamps Lamp Lamp Cataloguelength in width type length number

Wet 50-5/16" 1 T8 48" SW4C132Locations 50-5/16" 2 T8 48" SW4C232

50-5/16" 2 HO 48" SW4C248HO

Ordering Guide

Water tight hub kit: GWHB001

Reference Data

Efficiency 79.3%Spacing Ratio 1.6

Electronic Ballast

Input Watts (120V) 62.0WBallast Factor .88

LuminaireTypeSW

LuminaireLength4: 4’

Number oflamp in aluminairecross-section12

Lamp Type32: T8 4’34: T12 4’48 HO: T8 orT12 HO 4’

Voltage120277347

BallastSee page 110

OptionsSee page 110

Page 105: LRG CFI

1511

1000

500

0

30°

60°

8-9/32"(210.3 mm)

9-23/32"(246.8 mm)

9-23/32"(246.8 mm)

5-9/32" (134 mm)

8-9/32"(210.3 mm)

9-23/32"(246.8 mm)

9-23/32"(246.8 mm)

5-9/32" (134 mm)

112

Special Applications LuminairesHazardline 4’ (HSC)Fiberglass reinforced polyester composite body • Vapor / Dust / Wet Locations Enclosed

This luminaire is suitable for indoor and outdoor applications in threeareas. Class I Div. 2 locations are those in which flammable gases,vapors or liquids are handled in closed containers from which any escapeof hazardous materials are accidental. Class II locations are hazardousbecause of the presence of combustible dust. Class III locations arehazardous because of the presence of easily ignitable fibers or flyings. Inaddition, Hazardline has a wet location rating for use indoors.

Features•cUL-Listed Class I, Division 2, Groups A, B, C, and D locations.•cUL-Listed Class II, Divisions 1 and 2, Class III, Divisions 1 and 2

locations.•cUL-Listed for wet locations.•Non-corrosive fiberglass reinforced polyester composite body suitable

(T8 or T12RS) for 104°F (40°C) ambient temperature.•Meets UL 844 static discharge requirements.•Meets UL 746C impact Test requirements.•Meets UL 94-5VA fire rating.•Baked white acrylic enamel, 16 gauge stainless steel door frame with

3/16" tempered glass lens.•Rugged stainless steel toggle clamps to secure lens door frame.•1/2" NPT taper-threaded cast aluminum suspension hubs (4 per lumi-

naire).•One piece all-around gasketing.•Quick-change power-channel ballast design.•Marine grade also available.

HSCXT232120SO (Data)

Options pages 150-156Ballast Specify voltage (120, 277 or 347) and add suffix, e.g.HSCXT248HO277SS.Magnetic Electronic One-3 Lamp ElectronicT12: LEHO T12: BlankT8: OC T8: SO T8: O3Electrical/Wiring Options For special wiring, fusing, and emergencypack, consult factory.

Hazardous Location DefinitionThe following hazardous location definitions are excerpted from Article 500 ofthe 1990 National Electrical Code.Class I, Division 2 LocationsA Class I, Division 2 location is a location (1) in which volatile flammable liquidsor flammable gases are handled, processed, or used, but in which the liquids,vapors, or gases will normally be confined within closed containers or closedsystems from which they can escape only in case of accidental rupture orbreakdown of such containers or systems, or in case of abnormal operation ofequipment.Class II LocationsClass II locations are those that are hazardous because of the presence ofcombustible dust. (a) Class II, Division 1.A Class II, Division 1 location is a location: (1) which combustible dust is in theair under normal operating conditions, in quantities sufficient to produceexplosive or ignitible mixtures; or (2) where mechanical failure or abnormaloperation of machinery or equipment might cause such explosive or ignitiblemixtures to be produced, and might also provide a source of ignition throughsimultaneous failure of electric equipment, operation of protection devices, orfrom other causes; or (3) in which combustible dusts of an electrically conductivenature may be present in hazardous quantities.(b) Class II, Division 2A Class II, Division 2 location is a location where combustible dust is notnormally in the air in quantities sufficient to produce explosive or ignitiblemixtures, and dust accumulations are normally insufficient to interfere with thenormal operation of electrical equipment or other apparatus, but combustibledust may be in suspension in the air as a result of infrequent malfunctioning ofhandling or processing equipment and where combustible dust accumulationson, in, or in the vicinity of the electrical equipment may be sufficient to interferewith the safe dissipation of heat from electrical equipment or may be ignitible byabnormal operation or failure of electrical equipment.Class III LocationsClass III locations are those that are hazardous because of the presence ofeasily ignitible fibers or flyings, but in which such fibers or flyings are not likelyto be in suspension in the air in quantities sufficient to produce ignitiblemixtures.(a) Class III, Division 1.A Class III, Division 1 location is a location in which easily ignitible fibers ormaterials producing combustible flyings are handled, manufactured, or used.(b) Class III, Division 2.A Class III, Division 2 location is a location in which easily ignitible fibers arestored or handled.

RCR C. U.1 772 673 594 535 476 427 388 359 3210 30

SPECIALAPPLICATIONS

• T12 options are limited due to new regulations.Please consult factory for their availability.

• Please refer to page 13 for more information regarding the availability of T12 and the New Energy Efficient regulations set forth by National Resources Canada.

Page 106: LRG CFI

113

HS CXT 2 32 120 SO

*800 MA HO luminaires are standard with -20°F (-29°C) ballasts.

THERMAL PERFORMANCE OF HSCXT LUMINAIRES*Lamps Ambient “T” Luminaire

Quantity Type Temp. °C Numbers Temperature*2 T12/T8 40 T-4A 120°C (248°F)3 T12/T8 40 T-4A 120°C (248°F)2 HO 25 T-3C 160°C (320°F)

*Maximum temperature on any part of the luminaire.

Special Application Luminaires

Application Data*

Luminaire Spacing FC W/Sq Ft

50' x 70' x 12' Space

8' x 8' (64 sq ft/luminaire) 51 0.9

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 54 1.2

Type Class/ Luminaire Lamp Lamps Cataloguedivision length type in width number

Enclosed Vapor-tight 53" 2 x T8 2 HSCXT232Industrial Class I 2 x HO* 2 HSCXT248HOFluorescent Division 2 3 xT8 3 HSCXT332

Ordering GuideReference Data

Efficiency 72.8%Spacing Ratio 1.3

Electronic Ballast

Input Watts (120V) 62.0WBallast Factor .88

LuminaireTypeHS

DivisionCXT

Number oflamps23

Lamp Type32: T8 4’48 HO: T8or T12 HO34: T12 4’

Voltage120277347

BallastSee page112

OptionsSee page112

Options

Features

Hi-Temp Power Channel Heavy-Duty Hinged StainlessSteel Door

Top/End Suspension Hubs

45° Adjustable Quadrant BracketsSuffix: NKH45

*Average Footcandles Maintained Total LLF=.75 Reflectance: 80% Ceiling, 50% Wall, 20% Floor. RE835 lamp rated at 3000 lumens.

Page 107: LRG CFI

114

Features• Excellent for locations where vandal resistance is required.• Prismatic lens (VL) is 3/16" thick pattern 12, minimum impact

strength, 130 foot pounds.• Full perimeter gasketing (closed cell Neoprene) between door

frame and lens.• Tamper resistant holt head screws secure lens to housing.• 5" deep body, 2x2 and 2x4.• 74.4% efficient (T8), 2x4 4 lamp.• Hemmed over side rails for maximum safety.• Fixture ends turned-in for safe handling.• Built-in earthquake clips (patent no. 5,072,344), on 2x2 and 2x4.• Spring loaded rooster head latches.• 18 gauge steel hinges.• 69.3% efficient (T8), 2x2 2-6"U.• 62.2% efficient (T8), 1x4 2 lamp.

Options Page 520Ballast Specify voltage (120 or 277) and type and add as suffix, e.g. 120S0.Electrical/Wiring Options For special wiring, fusing, electronicdimming ballasts, consult factory.Seismic Hold-Down Clip For 1'x4' type G, Suffix: 2HD.Factory installed.Plaster Frame For F type troffers, order plaster frames separately.Catalog Number: PF24 for 2'x4' troffer; PF22 for 2'x2' troffer, PF14for 1'x4' troffer.Fusing Internal fast-blowing fusing. SUFFIX: GLR Internal slow-blowfusing. SUFFIX: GMF

BALLAST CODETYPE <20THD <10THDElectronic T8 SO* HI*1-3 Lamp T8 O3* H3*1-4 Lamp T8 O4* H4*1-3 Lamp TT5 40 Watt X3* I3*1&2 Lamp TT5 40 Watt SB* IB**Instant StartLens For optional 9/64" thick (VK) pattern 12, minimum impactstrength, 80 foot pounds, substitute VL with VK in Catalog No.i.e:GVS2GFSVK432.

90°

1000

2000

30000° 30°

60°

114

6" (152mm)

24" (610mm)

The VTS series combines the sharp cut-off of a VDT parabolic with thewide distribution and vertical illumination of a lens troffer in a uniquedesign that provides ideal illumination for video conferencing areas.

Features• Provides soft vertical illumination for comfortable televising of

participants.• Shields the camera from light sources and eliminates glare on the

projection screen.• Integrated specular parabolic blades and prismatic acrylic lens

assembly for directional brightness control.• 86 minimum VCP in rooms with less than 10' ceiling (3 lamp T8).• Spring-loaded latches.• Concealed “T” hinges.• Louver/lens assembly with positive light stop.• Four earthquake clips standard.

Options page 150-156Ballast Specify voltage (120 or 277) and type and add as suffix, e.g.120SOBALLAST CODETYPE <20THD <10THDElectronic T8 SO* HI*1-3 lamp T8 O3* H3*1-4 lamp T8 O4* H4*LOL Dimming PS*Instant StartElectrical/Wiring Options For special wiring, fusing, electronic dimming ballast, consult factory.Note: for drywall ceiling, use ”G” type fixtures with DRYWALL KIT, FK92X4.

Fusing Internal fast-blow fusing. Suffix: F.

VTS2GPK332120O3

SPECIALAPPLICATIONS

Special Application LuminairesVideo Teleconference 2’ x 4’ (VTS)Recessed Video Teleconferencing Parabolic

RCR C. U.1 672 633 584 555 516 487 458 429 3910 37

6" (152mm)

39-1/4" (997mm)

47-31/32" (1218mm)

2" x 2-1/2" access plate with two K.O.s(7/8" dia.)

Page 108: LRG CFI

115

VTS2GPK332 120 03

*Average Footcandles Maintained Total LLF=.75 Reflectance: 80% Ceiling, 50% Wall, 20% Floor. RE835 lamp rated at 3000 lumens.

Reference Data

Efficiency 59.7%Spacing Ratio 1.1

Electronic Ballast

Input Watts (120V) 85.0WBallast Factor 0.88

Special Application Luminaires

Type Size Lamps Grid Slot Gridqty/type

Static 2 X 4 2-T8 VTS2GPK232 VTS2TPK232Static 2 X 4 3-T8 VTS2GPK332 VTS2TPK332Static 2 X 4 4-T8 VTS2GPK432 VTS2TPK432

Ordering Guide

6' Min.

LampDirection End of

Fixture

ViewingScreen

TELECONFERENCING ORIENTATION

Application Data*

Luminaire Spacing FC W/Sq Ft

20' x 30' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 57.9 1.25

8' x 10' (80 sq ft/luminaire) 57.9 1.25

15' x 20' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 46.8 1.11

Basic catalogue number : Voltage : Ballast : Options :VideoTeleconference Recessed 120 See page 114 See page 114

277

Teleconference Lighting Recommendations1. I.E.S. recommends 50 maintained footcandles for teleconferencing.2. 3000K lamps with C.R.I. of 82 suggested for better skin tone.3. Teleconferencing luminaires are to be mounted in the ceiling with the lamps perpendicular to the wall

that the viewing screen is on.4. The end of the first fixture must be a minimum of 6 feet from the viewing screen (see diagram).5. Side and back walls should be illuminated to reduce contrast vs. other vertical surfaces. Use wall

lighting luminaires where necessary. 5:1 maximum luminance ratio suggested.6. It is suggested that Dimming Ballast be used to adjust for reflection surfaces in the zoom.

Page 109: LRG CFI

116

Features• Excellent for locations where vandal resistance is required.• Prismatic lens (VL) is 3/16" thick pattern 12, minimum impact

strength, 130 foot pounds.• Full perimeter gasketing (closed cell Neoprene) between door

frame and lens.• Tamper resistant holt head screws secure lens to housing.• 5" deep body, 2x2 and 2x4.• 74.4% efficient (T8), 2x4 4 lamp.• Hemmed over side rails for maximum safety.• Fixture ends turned-in for safe handling.• Built-in earthquake clips (patent no. 5,072,344), on 2x2 and 2x4.• Spring loaded rooster head latches.• 18 gauge steel hinges.• 69.3% efficient (T8), 2x2 2-6"U.• 62.2% efficient (T8), 1x4 2 lamp.

Options Page 520Ballast Specify voltage (120 or 277) and type and add as suffix, e.g. 120S0.Electrical/Wiring Options For special wiring, fusing, electronicdimming ballasts, consult factory.Seismic Hold-Down Clip For 1'x4' type G, Suffix: 2HD.Factory installed.Plaster Frame For F type troffers, order plaster frames separately.Catalog Number: PF24 for 2'x4' troffer; PF22 for 2'x2' troffer, PF14for 1'x4' troffer.Fusing Internal fast-blowing fusing. SUFFIX: GLR Internal slow-blowfusing. SUFFIX: GMF

BALLAST CODETYPE <20THD <10THDElectronic T8 SO* HI*1-3 Lamp T8 O3* H3*1-4 Lamp T8 O4* H4*1-3 Lamp TT5 40 Watt X3* I3*1&2 Lamp TT5 40 Watt SB* IB**Instant StartLens For optional 9/64" thick (VK) pattern 12, minimum impactstrength, 80 foot pounds, substitute VL with VK in Catalog No.i.e:GVS2GFSVK432.

116

1150

2300

3450

90°

0° 30°

60°24" (610mm)

6" (152mm)

23-7/8"(606mm)

15-11/16"(398mm)

5"(127mm)

The VTS series combines the sharp cut-off of a VDT parabolic with thewide distribution and vertical illumination of a lens troffer in a unique design that providesideal illumination for video conferencing areas.

Features• Provides soft vertical illumination for comfortable televising

of participants.• Shields the camera from light sources and eliminates glare

on the projection screen.• Integrated specular parabolic blades and

prismatic acrylic lens assembly for directionalbrightness control.

• 77 minimum VCP in rooms with less than 10' ceiling (3 lamp T5).

• Spring-loaded latches.• Concealed “T” hinges.• Louver/lens assembly with positive light stop.• Four earthquake clips standard.

Options page 150-156Ballast Specify voltage (120 or 277) and type and add as suffix, e.g. 120SO.

BALLAST CODETYPE <20THD <10THDElectronic T8 SO* HI*Electronic T8 SO* HI*1-3 lamp T8 O3* H3*Electronic TT5 SB* IB*1-3 LAMP TT5-40 Watt X3* I3*LOL Dimming TT5 PB*Instant StartElectrical/Wiring Options For special wiring, fusing, electronic dim-ming ballast, consult factory.Note: for drywall ceiling, use “G” type fixtures with DRYWALL KIT, FK92X2.Fusing Internal fast-blow fusing. Suffix: F.

2"x2-1/2" access platewith two K.O.s (7/8" dia.)

Special Application LuminairesVideo Teleconference 2’ x 2’ (VTS)Recessed Video Teleconferencing Parabolic

VTS2GPK3FT120X3

RCR C. U.1 622 583 544 515 486 457 428 399 3710 35

SPECIALAPPLICATIONS

Page 110: LRG CFI

117* Pieds-bougies moyens maintenus. LLF Total = .75 Réflectivité : Plafond :80% mur : 50% plancher : 20%. Lampe de type RE835 évaluée à 3000 lumens.

VTS2GPK3FT 120 X3

Type Size Lamps Grid Slot Gridqty/type

Static 2 X 2 2-T8 6”U VTS2GPK26U VTS2TPK26UStatic 2 X 2 2-TT5 VTS2GPK2FT VTS2TPK2FTStatic 2 X 2 3-T8 1.6U VTSGPK32U VTSTPK32UStatic 2 X 2 3-TT5 VTSGPK3FT VTSTPK3FT

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :VideoTeleconference Recessed 120 See page 116 See page 116

277

Reference Data

Efficiency 55.1%Spacing Ratio 1.2

Electronic Ballast

Input Watts (120V) 103.0WBallast Factor 0.88

Application Data*

Luminaire Spacing FC W/Sq Ft

20' x 30' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 59.4 1.54

8' x 10' (80 sq ft/luminaire) 59.4 1.54

15' x 20' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 48.2 1.37

Teleconference Lighting Recommendations1. I.E.S. recommends 50 maintained footcandles for teleconferencing.2. 3000K lamps with C.R.I. of 82 suggested for better skin tone.3. Teleconferencing luminaires are to be mounted in the ceiling with the lamps perpendicular to

the wall that the viewing screen is on.4. The end of the first fixture must be a minimum of 6 feet from the viewing screen (see diagram).5. Side and back walls should be illuminated to reduce contrast vs. other vertical surfaces. Use

wall lighting luminaires where necessary. 5:1 maximum luminance ratio suggested.6. It is suggested that Dimming Ballast be used to adjust for reflection surfaces in the zoom.

6' Min.

LampDirection

End ofFixture

ViewingScreen

TELECONFERENCING ORIENTATION

Special Application Luminaires

Page 111: LRG CFI

118

Features• Excellent for locations where vandal resistance is required.• Prismatic lens (VL) is 3/16" thick pattern 12, minimum impact

strength, 130 foot pounds.• Full perimeter gasketing (closed cell Neoprene) between door

frame and lens.• Tamper resistant holt head screws secure lens to housing.• 5" deep body, 2x2 and 2x4.• 74.4% efficient (T8), 2x4 4 lamp.• Hemmed over side rails for maximum safety.• Fixture ends turned-in for safe handling.• Built-in earthquake clips (patent no. 5,072,344), on 2x2 and 2x4.• Spring loaded rooster head latches.• 18 gauge steel hinges.• 69.3% efficient (T8), 2x2 2-6"U.• 62.2% efficient (T8), 1x4 2 lamp.

Options Page 520Ballast Specify voltage (120 or 277) and type and add as suffix, e.g. 120S0.Electrical/Wiring Options For special wiring, fusing, electronicdimming ballasts, consult factory.Seismic Hold-Down Clip For 1'x4' type G, Suffix: 2HD.Factory installed.Plaster Frame For F type troffers, order plaster frames separately.Catalog Number: PF24 for 2'x4' troffer; PF22 for 2'x2' troffer, PF14for 1'x4' troffer.Fusing Internal fast-blowing fusing. SUFFIX: GLR Internal slow-blowfusing. SUFFIX: GMF

BALLAST CODETYPE <20THD <10THDElectronic T8 SO* HI*1-3 Lamp T8 O3* H3*1-4 Lamp T8 O4* H4*1-3 Lamp TT5 40 Watt X3* I3*1&2 Lamp TT5 40 Watt SB* IB**Instant StartLens For optional 9/64" thick (VK) pattern 12, minimum impactstrength, 80 foot pounds, substitute VL with VK in Catalog No.i.e:GVS2GFSVK432.

118

0°30°

60°

90°

500

1000

1500

0°30°

60°

90°750

1500

2250

24" (610mm)

5"(127mm)

24" (610mm)

5"(127mm)

Special Application LuminairesCleanguard Class 1,000 - 2’x 2’, 2’x 4’ (CXSW)Recessed Class 1,000 Clean Room / Wet Location Enclosed

RCR C. U.1 692 633 574 535 486 457 428 399 3510 34Features

• Meets requirements for Federal Standard 209E Class 1,000/10,000& 100,000 Clean Room tested by Independent Lab.

• UL and ULc Listed for wet or damp locations for covered ceiling use.• Fits 15/16" to 1-1/2" wide face grid ceiling systems. Contractor

responsible for sealing fixture to ceiling.• Full perimeter gasketing (closed cell Neoprene) between door

frame and lens, closed cell ethafoam gasketing between housingand door frame.

• Ends sealed to body.• .125 pattern 12 lens installed smooth side down.• Door frame is post painted, baked acrylic enamel.• Hemmed over side rails for maximum safety.• Spring loaded rooster head latches.• 18 gauge steel hinges.• Flat extruded aluminum door.

Options page 150-156Ballast Specify voltage (120 or 277) and type and add as suffix, e.g. 120SO.

BALLAST CODETYPE <20THD <10THDElectronic T8 SO* HI*1-3 Lamp T8 O3* H3*1-4 Lamp T8 O4* H4*Electronic TT5 (40Watt) SB* IB*1-3 Lamp TT5 (40Watt) X3* I3** Instant Start

Electrical/Wiring Options For special wiring, fusing, electronicdimming ballasts, consult factory.

Fusing Internal fast-blowing fusing. SUFFIX:F

SPECIALAPPLICATIONS

CXS2WFAVI26U120SO

CXS2WFAVI33212003

RCR C. U.1 742 683 624 565 526 487 458 419 3910 36

SPECIALAPPLICATIONS

Page 112: LRG CFI

CXS2WFAVI26U120S0 120 SO

119

CXS2WFAVI332 120 SO

Reference Data

Efficiency 63.1%Spacing Ratio 1.2

Electronic Ballast

Input Watts (120V) 60.0WBallast Factor 0.88

Reference Data

Efficiency 67.9%Spacing Ratio 1.2

Electronic Ballast

Input Watts (120V) 85.0WBallast Factor 0.88

2 X 2 Lamps 15/16" to 1-1/2" Wide Face T-Gridqty/type

Flat 2-6” T8 CXS2WFAVI26UAluminum 3-TT5 CXS2WFAVI3FTDoor 3-1.6" UT8 CXS2WFAVI32U

Application Data*

Luminaire Spacing FC W/Sq Ft

30' x 30' x 8.5' Space

6' x 6' (36 sq ft/luminaire) 70.7 1.49

8' x 8' (48 sq ft/luminaire) 45.3 0.95

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 59.6 1.68

Application Data*

Luminaire Spacing FC W/Sq Ft

30' x 30' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 75.5 1.51

8' x 10' (80 sq ft/luminaire) 94.3 1.88

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 66 1.77

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :Cleanguard wet location 120 See page 118 See page 118Class 1000 277 Add appropriate10,000 UNV Universal suffix 100,000 Voltage 120-277Clean Room T8 or TT5 only

2 X 2 Lamps 15/16" to 1-1/2" Wide Face T-Gridqty/type

Flat 2-T8 CXS2WFAVI232Aluminum 3-T8 CXS2WFAVI332Door 4-T8 CXS2WFAVI432

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :Cleanguard wet location 120 See page 118 See page 118Class 1000 277 Add appropriate10,000 UNV Universal suffix 100,000 Voltage 120-277Clean Room T8

Exposed T-grid ceiling, 1-1/2" face,(with flat aluminum frame).

Exposed T-grid ceiling 15/16" to 1"face (with flat aluminum frame).

24"

1-1/2"

1/4" max.

1 1/2" max.

gasketing

gasketing

24"

1/4" max.

1 1/2" max.

15/16" or 1"

gasketing

gasketing

Mounting Methods

*Average Footcandles Maintained Total LLF=.75 Reflectance: 80% Ceiling, 50% Wall, 20% Floor. RE835 lamp rated at 3000 lumens.

Special Application Luminaires

Page 113: LRG CFI

120

Features• Excellent for locations where vandal resistance is required.• Prismatic lens (VL) is 3/16" thick pattern 12, minimum impact

strength, 130 foot pounds.• Full perimeter gasketing (closed cell Neoprene) between door

frame and lens.• Tamper resistant holt head screws secure lens to housing.• 5" deep body, 2x2 and 2x4.• 74.4% efficient (T8), 2x4 4 lamp.• Hemmed over side rails for maximum safety.• Fixture ends turned-in for safe handling.• Built-in earthquake clips (patent no. 5,072,344), on 2x2 and 2x4.• Spring loaded rooster head latches.• 18 gauge steel hinges.• 69.3% efficient (T8), 2x2 2-6"U.• 62.2% efficient (T8), 1x4 2 lamp.

Options Page 520Ballast Specify voltage (120 or 277) and type and add as suffix, e.g. 120S0.Electrical/Wiring Options For special wiring, fusing, electronicdimming ballasts, consult factory.Seismic Hold-Down Clip For 1'x4' type G, Suffix: 2HD.Factory installed.Plaster Frame For F type troffers, order plaster frames separately.Catalog Number: PF24 for 2'x4' troffer; PF22 for 2'x2' troffer, PF14for 1'x4' troffer.Fusing Internal fast-blowing fusing. SUFFIX: GLR Internal slow-blowfusing. SUFFIX: GMF

BALLAST CODETYPE <20THD <10THDElectronic T8 SO* HI*1-3 Lamp T8 O3* H3*1-4 Lamp T8 O4* H4*1-3 Lamp TT5 40 Watt X3* I3*1&2 Lamp TT5 40 Watt SB* IB**Instant StartLens For optional 9/64" thick (VK) pattern 12, minimum impactstrength, 80 foot pounds, substitute VL with VK in Catalog No.i.e:GVS2GFSVK432.

120

0°30°

60°

90°

500

1000

1500

0°30°

60°

90°

750

1500

2250

5" (127mm)

24" (610mm)

5" (127mm)

24" (610mm)

SPECIALAPPLICATIONS

Special Application LuminairesCleanguard Class 10,000 - 2’x 2’, 2’x 4’ (CXS)Recessed Class 10,000 Clean Room / Wet Location Enclosed

Features• Meets requirements for Federal Standard 209E

Class 10,000 & 100,000 Clean Room tested by Independent Lab.• UL and ULc Listed for wet or damp locations for

covered ceiling use.• Fits 15/16" to 1" wide face grid ceiling systems or flanged for

drywall type ceilings. Contractor responsible for sealing fixture to ceiling.

• Full perimeter gasketing (closed cell Neoprene) between door frame and lens, between housing and door frame.

• Ends sealed to body.• .125 pattern 12 lens installed smooth side down.• Door frame is post painted, baked acrylic enamel.• Hemmed over side rails for maximum safety.• Spring loaded rooster head latches.• 18 gauge steel hinges.• Flat and regressed aluminum doors available.

Options page 150-156Ballast Specify voltage (120, 277 or UNV) and type and add as suffix,e.g. 120SO.

BALLAST CODETYPE <20THD <10THDElectronic T8 SO* HI*1 - 3 Lamp Elec T8 O3* H3*1 - 4 Lamp Elec T8 O4* H4*Electronic TT5 (40 Watt) SB* IB*1 - 3 Lamp TT5 (40 Watt) X3* I3**Instant Start

Electrical/Wiring Options For special wiring, fusing, electronic dimming ballasts, consult factory.

Plaster Frame Order plaster frames separately. Catalog Number: FK92X4 for 2'x4' troffer, FK92X2 for 2'x2' troffer.

Fusing Internal fast-blow fusing. Suffix: F.

CXS2GFSVI26U120SO

RCR C. U.1 692 633 574 535 486 457 428 399 3510 34

CXS2GFSVI332120O3

RCR C. U.1 742 683 624 565 526 487 458 419 3910 36

Page 114: LRG CFI

121

CXS2GFSVI26U 120 SO

CXS2GFSVI332 120 SO

Special Application Luminaires

Reference Data

Efficiency 63.1%Spacing Ratio 1.2

Electronic Ballast

Input Watts (120V) 60.0WBallast Factor 0.88

Application Data*

Luminaire Spacing FC W/Sq Ft

30' x 30' x 8.5' Space

6' x 6' (36 sq ft/luminaire) 70.7 1.49

8' x 8' (64 sq ft/luminaire) 45.3 0.95

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 59.6 1.68

2 X 2 Lamps Exposed Flanged forWideqty/type T-Grid Dry or Plaster

Flat 2-6” T8 CXS2GFAVI26U CXS2FFAVI26UAluminum 3-TT5 CXS2GFAVI3FT CXS2FFAVI3FTDoor 3-1.6" UT8 CXS2GFAVI32U CXS2FFAVI32UFlat 2-6” T8 CXS2GFSVI26U CXS2FFSVI26USteel Door 3-TT5 CXS2GFSVI3FT CXS2FFSVI3FT

3-1.6"U T8 CXS2GFSVI32U CXS2FFSVI32URegressed 2-6" T8 CXS2GRAVI26U CXS2FRAVI26UAluminum 3-TT5 CXS2GRAVI3FT CXS2FRAVI3FTDoor 3-1.6"U T8 CXS2GRAVI32U CXS2FRAVI32U

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :Cleanguard wet location 120 See page 120 See page 120Class 277 Add appropriate10,000 UNV Universal suffix 100,000 Voltage 120-277Clean Room T8 or TT5 only

Reference Data

Efficiency 67.9%Spacing Ratio 1.2

Electronic Ballast

Input Watts (120V) 85.0WBallast Factor 0.88

Application Data*

Luminaire Spacing FC W/Sq Ft

30' x 30' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 75.5 1.51

8' x 10' (80 sq ft/luminaire) 94.3 1.88

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 66 1.77

2 X 4 Lamps Exposed Flanged forWideqty/type T-Grid Dry or Plaster

Flat 2-T8 CXS2GFAVI232 CXS2FFAVI2320Aluminum 3-T8 CXS2GFAVI332 CXS2FFAVI332Door 4-T8 CXS2GFAVI432 CXS2FFAVI432Flat 2-T8 CXS2GFSVI232 CXS2FFSVI232Steel Door 3-T8 CXS2GFSVI332 CXS2FFSVI332

4-T8 CXS2GFSVI432 CXS2FFSVI432Regressed 2-T8 CXS2GRAVI232 CXS2FRAVI232Aluminum 3-T8 CXS2GRAVI332 CXS2FRAVI332Door 4-T8 CXS2GRAVI432 CXS2FRAVI432

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :Class 10,000 120 See page 120 See page 120100,000 277 Add appropriateClean Room UNV Universal suffix

Voltage 120-277T8

*Average Footcandles Maintained Total LLF=.75 Reflectance: 80% Ceiling, 50% Wall, 20% Floor. RE835 lamp rated at 3000 lumens.

Page 115: LRG CFI

122

Features• Excellent for locations where vandal resistance is required.• Prismatic lens (VL) is 3/16" thick pattern 12, minimum impact

strength, 130 foot pounds.• Full perimeter gasketing (closed cell Neoprene) between door

frame and lens.• Tamper resistant holt head screws secure lens to housing.• 5" deep body, 2x2 and 2x4.• 74.4% efficient (T8), 2x4 4 lamp.• Hemmed over side rails for maximum safety.• Fixture ends turned-in for safe handling.• Built-in earthquake clips (patent no. 5,072,344), on 2x2 and 2x4.• Spring loaded rooster head latches.• 18 gauge steel hinges.• 69.3% efficient (T8), 2x2 2-6"U.• 62.2% efficient (T8), 1x4 2 lamp.

Options Page 520Ballast Specify voltage (120 or 277) and type and add as suffix, e.g. 120S0.Electrical/Wiring Options For special wiring, fusing, electronicdimming ballasts, consult factory.Seismic Hold-Down Clip For 1'x4' type G, Suffix: 2HD.Factory installed.Plaster Frame For F type troffers, order plaster frames separately.Catalog Number: PF24 for 2'x4' troffer; PF22 for 2'x2' troffer, PF14for 1'x4' troffer.Fusing Internal fast-blowing fusing. SUFFIX: GLR Internal slow-blowfusing. SUFFIX: GMF

BALLAST CODETYPE <20THD <10THDElectronic T8 SO* HI*1-3 Lamp T8 O3* H3*1-4 Lamp T8 O4* H4*1-3 Lamp TT5 40 Watt X3* I3*1&2 Lamp TT5 40 Watt SB* IB**Instant StartLens For optional 9/64" thick (VK) pattern 12, minimum impactstrength, 80 foot pounds, substitute VL with VK in Catalog No.i.e:GVS2GFSVK432.

122

0°30°

60°

90°

0°30°

60°

90°

600

1200

1800

0°30°

60°

90°

1250

2500

3750

5"(127mm)

24" (610mm)

4-3/4"(44.4mm)

12" (304.8mm)

5" (127mm)

24" (610mm)

SPECIALAPPLICATIONS

Special Application LuminairesCleanguard Wet Location 1’x 4’, 2’x 2’, 2’x 4’ (WES)Recessed Lens / Wet Location Enclosed

Features• UL and C-UL Listed for wet or damp locations for covered

ceiling use.• Full perimeter gasketing (closed cell Neoprene) between door

frame and lens, between housing and door frame.• Door frame is post painted, baked acrylic enamel.• 5" deep body for 2x4 and 2x2.• 81.2% efficient (T8), 2x4 4 lamp.• 71.6% efficient (T8), 2-6"U.• 64.6% efficient (T8). 1x4 2 lamp.• Hemmed over side rails for maximum safety.• Fixture ends turned-in for safe handling.• Built-in earthquake clips (patent no. 5,072,344) 2x4, 2x2.• Slimline door frame with 1000 square inch lens opening

on 2x4 door.• Mitered corner steel lens frame.• Spring loaded rooster head latches.• 18 gauge steel hinges.• Flat and regressed aluminum doors available.

Options page 150-156

Ballast Specify voltage (120, 277 or UNV) and type and add as suffix,e.g. 120SO.

BALLAST CODETYPE <20THD <10THDElectronic T8 SO* HI*1 - 3 Lamp Elec T8 O3* H3*1 - 4 Lamp Elec T8 O4* H4*Electronic TT5 (40 Watt) SB* IB*1 - 3 Lamp TT5 (40 Watt) X3* I3**Instant StartEmergency/Wiring Options For special wiring, fusing, electronicdimming ballasts, consult factory.Seismic Hold-Down Clip For 1'x4', type G, Suffix: 2HD. FactoryInstalled.Plaster Frame For F type F, order plaster frames separately. CatalogNumber: FK92X4 for 2'x4' troffer, FK92X2 for 2'x2' troffer; FK91X4 for1’x4’ troffer.Fusing Internal fast-blow fusing. SUFFIX: F.Continuous Row Installation For 1'x4'Cat. #: FK91X4-CRM

WES1GFAVA232120SO

RCR C. U.1 712 653 604 565 516 487 448 419 3710 35

WES2GFAVA26U120SO

RCR C. U.1 792 723 664 615 566 527 498 459 4210 40

WES2GFAVA43212004

RCR C. U.1 892 823 754 695 646 597 558 519 4810 45

Page 116: LRG CFI

WES1GFAVA232 120 SO GLR

WES2GFAVA26U 120 SO GLR

WES2GFAVA432 120 SO GLR

123*Average Footcandles Maintained Total LLF=.75 Reflectance: 80% Ceiling, 50% Wall, 20% Floor. RE835 lamp rated at 3000 lumens.

Special Application Luminaires

Reference Data

Efficiency 64.6%Spacing Ratio 1.3

Electronic Ballast

Input Watts (120V) 62.0WBallast Factor 0.88

Application Data*

Luminaire Spacing FC W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 50.4 1.23

8' x 10' (80 sq ft/luminaire) 39.2 0.96

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 69.6 2.5

1 X 4 Lamps Exposed Flanged forWideqty/type T-Grid Dry or Plaster

Flat Steel Door 2-T8 WES1GFSVA232 WES1FFSVA232Regressed Aluminum Door 2-T8 WES1GRAVA232 WES1FRAVA232Flat Aluminum Door 2-T8 WES1GFAVA232 WES1FFAVA232

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :Cleanguard wet location 120 See page 122 See page 122

277UNV

Reference Data

Efficiency 71.6%Spacing Ratio 1.2

Electronic Ballast

Input Watts (120V) 60.0WBallast Factor 0.88

Application Data*

Luminaire Spacing FC W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 51.2 0.87

8' x 10' (80 sq ft/luminaire) 39.8 0.68

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 70 1.76

Ordering Guide2 X 2 Lamps Exposed Flanged forWide

qty/type T-Grid Dry or PlasterFlat 2-6" T8 WES2GFSVA26U WES2FFSVA26USteel 3-TT5 WES2GFSVA3FT WES2FFSVA3FTDoor 3-1.6"U T8 WES2GFSVA32U WES2FFSVA32URegressed 2-6" T8 WES2GRAVA26U WES2FRAVA26UAluminum 3-TT5 WES2GRAVA3FT WES2FRAVA3FTDoor 3-1.6"U T8 WES2GRAVA32U WES2FRAVA32UFlat 2-6" T8 WES2GFAVA26U WES2FFAVA26UAluminum 3-TT5 WES2GFAVA3FT WES2FFAVA3FTDoor 3-1.6"U T8 WES2GFAVA32U WES2FFAVA32U

Reference Data

Efficiency 81.2%Spacing Ratio 1.2

Electronic Ballast

Input Watts (120V) 83.0WBallast Factor 0.88

Application Data*

Luminaire Spacing FC W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 120.2 1.68

8' x 10' (80 sq ft/luminaire) 109.1 1.52

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 108.9 2.26

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :Cleanguard wet location 120 See page 122 See page 122

277UNV universal voltage120277Voltage Elec.T8 or TT5 only

2 X 4 Lamps Exposed Flanged forWideqty/type T-Grid Dry or Plaster

Flat 2-T8 WES2GFSVA232 WES2FFSVA232Steel 3-T8 WES2GFSVA332 WES2FFSVA332Door 4-T8 WES2GFSVA432 WES2FFSVA432Regressed 2-T8 WES2GRAVA232 WES2FRAVA232Aluminum 3-T8 WES2GRAVA332 WES2FRAVA332Door 4-T8 WES2GRAVA432 WES2FRAVA432Flat 2-T8 WES2GFAVA232 WES2FFAVA232Aluminum 3-T8 WES2GFAVA332 WES2FFAVA332Door 4-T8 WES2GFAVA432 WES2FFAVA432

Basic catalogue number : Voltage : Ballast : Options :Cleanguard wet location 120 See page 122 See page 122

277UNV

Page 117: LRG CFI

124

Features• Excellent for locations where vandal resistance is required.• Prismatic lens (VL) is 3/16" thick pattern 12, minimum impact

strength, 130 foot pounds.• Full perimeter gasketing (closed cell Neoprene) between door

frame and lens.• Tamper resistant holt head screws secure lens to housing.• 5" deep body, 2x2 and 2x4.• 74.4% efficient (T8), 2x4 4 lamp.• Hemmed over side rails for maximum safety.• Fixture ends turned-in for safe handling.• Built-in earthquake clips (patent no. 5,072,344), on 2x2 and 2x4.• Spring loaded rooster head latches.• 18 gauge steel hinges.• 69.3% efficient (T8), 2x2 2-6"U.• 62.2% efficient (T8), 1x4 2 lamp.

Options Page 520Ballast Specify voltage (120 or 277) and type and add as suffix, e.g. 120S0.Electrical/Wiring Options For special wiring, fusing, electronicdimming ballasts, consult factory.Seismic Hold-Down Clip For 1'x4' type G, Suffix: 2HD.Factory installed.Plaster Frame For F type troffers, order plaster frames separately.Catalog Number: PF24 for 2'x4' troffer; PF22 for 2'x2' troffer, PF14for 1'x4' troffer.Fusing Internal fast-blowing fusing. SUFFIX: GLR Internal slow-blowfusing. SUFFIX: GMF

BALLAST CODETYPE <20THD <10THDElectronic T8 SO* HI*1-3 Lamp T8 O3* H3*1-4 Lamp T8 O4* H4*1-3 Lamp TT5 40 Watt X3* I3*1&2 Lamp TT5 40 Watt SB* IB**Instant StartLens For optional 9/64" thick (VK) pattern 12, minimum impactstrength, 80 foot pounds, substitute VL with VK in Catalog No.i.e:GVS2GFSVK432.

124

0°30°

60°

90°

1000

500

SPECIALAPPLICATIONS

Special Application LuminaireRV Guardsman Corner Mount 2’, 3’, 4’, (RV)Surface Security for High Abuse Applications

RV Guardsman provides lighting solutions for maximum, medium, mini-mum security or high abuse areas. It includes fixtures for surface,recessed or corner wall mounting applications. A variety of temperedglass or polycarbonate lenses are available. To prevent forced access tothe lamp compartment there is no protruding hardware and all screwsare tamperproof.

Features:

• Post painted 14-20 gauge CRS body• Overlapped and welded corners• Door frame secured by piano hinge and 4 TORX screws• One piece CRS door frame in 14-20 gauge CRS• Lens retained by one piece inner frame• Choice of prismatic acrylic, Prismatic polycarbonate or clear tem-

pered glass• 14 gauge cold rolled steel (maximum security)• 16 gauge cold rolled steel (medium security)• 18 gauge cold rolled steel (minimum security)

OptionsBallast Specifiy voltage (120,277 or 347v) and add suffix e.g.(120SO)Magnetic ElectronicT8:OC 1 or 2 LPB T8: SO

3 LPB T8:O34 LPB T8:O4

LPB: Number of lamps per ballastElectrical/Wiring Options:Consult factory

RVX1CXDUS232120SO

RCR C. U.1 442 393 364 335 306 277 258 239 2110 20

Page 118: LRG CFI

RV X 1 C XD US 2 32 120 SO

125

Special Application Luminaires

Reference Data

Efficiency 41.70%Spacing Ratio

Electronic Ballast

Input Watts (120V) 62.0WBallast Factor 0.88

Application Data*

Luminaire Spacing FC W/Sq Ft

10' x 12' x 10' Sobering Cell

6' x 8' (48 sq ft/luminaire) 31 1.9

(6 inmates / 20 sq ft per inmate)

12' x 16' x 10' Space

6' x 4' (48 sq ft/luminaire) 22.4 1.19

8' x 8' x 10' Single Occupancy

6' x 8' (48 sq ft/luminaire) 23.2 1.78

Ordering GuideLamp 2' long 3' long 4' long

Maximum Security 1-T8 RVX1CXDUS117 RVX1CXDUS125 RVX1CXDUS1322-T8 RVX1CXDUS217 RVX1CXDUS225 RVX1CXDUS2323-T8 RVX1CXDUS317 RVX1CXDUS325 RVX1CXDUS332

Medium Security 1-T8 RVD1CXDSUT17 RVD1CDSUT125 RVD1CDSUT1322-T8 RVD1CDSUT217 RVD1CDSUT225 RVD1CDSUT2323-T8 RVD1CDSUT317 RVD1CDSUT325 RVD1CDSUT332

Minimum Security 1-T8 RVN1CNSPY117 RVN1CNSPY125 RVN1CNSPY1322-T8 RVN1CNSPY217 RVN1CNSPY225 RVN1CNSPY2323-T8 RVN1CNSPY317 RVN1CNSPY325 RVN1CNSPY332

Vandal Resistant 1-T8 RVT1CFSVK117 RVT1CFSVK125 RVT1CFSVK1322-T8 RVT1CFSVK217 RVT1CFSVK225 RVT1CFSVK2323-T8 RVT1CFSVK317 RVT1CFSVK325 RVT1CFSVK332

Luminaire Luminaire Luminaire Mounting Door Frame Lens/Shielding Lamp Quantity Lamp/Type Voltage Ballast OptionsType Gauge Width Style in a luminaire

cross-sectionRV SERIES X: Maximum 14 1: Nominal 12" C: Corner XD: Maximum US: .250" Clear 1: 1 lamp 17: T8 17W 120 SO: Elect.T8 Consult

Gauge Housing Security 14 Gauge Polycarbnoate with 2: 2 lamps 1-2 lamp I.S. factoryDouble Door Frame .125" acrylic overlay 3: 3 lamps 25: T8 25Wwith Piano hinge

D: Medium Security DS: Medium CG: Pattern 73 .140" 32: T8 32W 277 Consult factory16 Gauge Housing Security 16 Gauge Tempered Glass for other ballast

Steel Door Frame optionswith Piano hinge

N: Minimum Security NS: Minimum UT: .125" Clear 34718 Gauge Housing Security 18 Gauge Polycarbonate

Steel Door Frame with .125" acrylic overlayPY: Pattern 12 .187" UNVnominal PolycarbonateVK: Pattern 12 .140" AcrituffVX: Pattern 12 .125" nominal Polycarbonate

*Average Footcandles Maintained Total LLF=.82 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens

Page 119: LRG CFI

126

Features• Excellent for locations where vandal resistance is required.• Prismatic lens (VL) is 3/16" thick pattern 12, minimum impact

strength, 130 foot pounds.• Full perimeter gasketing (closed cell Neoprene) between door

frame and lens.• Tamper resistant holt head screws secure lens to housing.• 5" deep body, 2x2 and 2x4.• 74.4% efficient (T8), 2x4 4 lamp.• Hemmed over side rails for maximum safety.• Fixture ends turned-in for safe handling.• Built-in earthquake clips (patent no. 5,072,344), on 2x2 and 2x4.• Spring loaded rooster head latches.• 18 gauge steel hinges.• 69.3% efficient (T8), 2x2 2-6"U.• 62.2% efficient (T8), 1x4 2 lamp.

Options Page 520Ballast Specify voltage (120 or 277) and type and add as suffix, e.g. 120S0.Electrical/Wiring Options For special wiring, fusing, electronicdimming ballasts, consult factory.Seismic Hold-Down Clip For 1'x4' type G, Suffix: 2HD.Factory installed.Plaster Frame For F type troffers, order plaster frames separately.Catalog Number: PF24 for 2'x4' troffer; PF22 for 2'x2' troffer, PF14for 1'x4' troffer.Fusing Internal fast-blowing fusing. SUFFIX: GLR Internal slow-blowfusing. SUFFIX: GMF

BALLAST CODETYPE <20THD <10THDElectronic T8 SO* HI*1-3 Lamp T8 O3* H3*1-4 Lamp T8 O4* H4*1-3 Lamp TT5 40 Watt X3* I3*1&2 Lamp TT5 40 Watt SB* IB**Instant StartLens For optional 9/64" thick (VK) pattern 12, minimum impactstrength, 80 foot pounds, substitute VL with VK in Catalog No.i.e:GVS2GFSVK432.

126

0°30°

60°

90°

1000

2000

3000

0°30°

90°

60°

1200

800

400

0°30°

60°

90°

1200

400

800

23 5/8"

4 1/2"

48"

23 5/8"

4 1/2"

48"

SPECIALAPPLICATIONS

Security FixturesRV Guardsman Surface 1’x 4’, 2’x 2’, 2’x 4’ (RV)Surface Security For High Abuse Applications

RV Guardsman provides lighting solutions for maximum, medium, mini-mum security or high abuse areas. It includes fixtures for surface,recessed or corner wall mounting applications. A variety of temperedglass or polycarbonate lenses are available. To prevent forced access tothe lamp compartment there is no protruding hardware and all screwsare tamperproof.

Features:• Post painted 14-20 gauge CRS body• Overlapped and welded corners• Door frame secured by piano hinge and 4 TORX scres• One piece CRS door frame in 14-20 gauge CRS• Lens retained by one piece inner frame• Choice of prismatic acrylic, Prismatic polycarbonate or clear tem-

pered glass• 14 gauge cold rolled steel (maximum security)• 16 gauge cold rolled steel (medium security)• 18 gauge cold rolled steel (minimum security)

OptionsBallast Specifiy voltage (120,277 or 347v) and add suffix e.g.(120SO)Magnetic ElectronicT8:OC 1 or 2 LPB T8: SO

3 LPB T8:O34 LPB T8:O4

LPB: Number of lamps per ballastElectrical/Wiring Options:Consult factory

RVX1SXDUS232120SO

RCR C. U.1 472 433 404 375 346 327 298 279 2510 23

RVX2SXDUS26U120SO

RVX2SXDUS432120O4

RCR C. U.1 582 543 504 455 426 397 368 339 3110 28

RCR C. U.1 572 523 494 455 416 387 358 329 3010 28

Page 120: LRG CFI

127

RV X 1 S XD US 2 32 120 04

Special Applications Luminaires

Reference Data

Efficiency 41.70%Spacing Ratio 1.2

Electronic Ballast

Input Watts (120V) 62.0WBallast Factor 0.88

Application Data*

Luminaire Spacing FC W/Sq Ft

10' x 12' x 10' Sobering Cell

6' x 8' (48 sq ft/luminaire) 33.6 1.9

(6 inmates / 20sq ft per inmate)

8' x 8' x 10' Single Occupancy

6' x 4' (48 sq ft/luminaire) 25.6 1.78

Reference Data

Efficiency 52.10%Spacing Ratio 1.2

Electronic Ballast

Input Watts (120V) 60.0WBallast Factor 0.88

Reference Data

Efficiency 51.00%Spacing Ratio 1.2

Electronic Ballast

Input Watts (120V) 112.0WBallast Factor 0.88

Application Data*

Luminaire Spacing FC W/Sq Ft

50' x 70' x 10'

8' x 8' (64 sq ft/luminaire) 33.1 0.79

12' x 16 x 10'

6' x 8' (48 sq ft/luminaire) 31.6 1.21

8' x 8' x 10'

6' x 8' (48 sq ft/luminaire) 33.5 1.81

Application Data*

Luminaire Spacing FC W/Sq Ft

50' x 70' x 10'

8' x 8' (64 sq ft/luminaire) 49.8 1.06

12' x 16 x 10

6' x 8' (48 sq ft/luminaire) 32.4 1.11

8' x 8' x 10'

6' x 8' (48 sq ft/luminaire) 32.4 1.11

*Average Footcandles Maintained Total LLF=.82 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens

Luminaire Luminaire Luminaire Mounting Door Frame Lens/Shielding Lamp Quantity Lamp/Type Voltage Ballast OptionsType Gauge Width Style in a luminaire

cross-sectionRV SERIES X: Maximum 14 1: Nominal 12" S: Surface XD: Maximum US: .250" Clear 2: 2 lamps 32: T8 32W 120 SO: Elect.T8 Consult

Gauge Housing 2: Nominal 24" Security 14 Gauge Polycarbnoate with 3: 3 lamps 1-2 lamp I.S. factoryDouble Door Frame .125" acrylic overlay 4: 4 lampswith Piano hinge

D: Medium Security DS: Medium CG: Pattern 73 .140" 6U: 6” U-T8 277 03: Elect.T816 Gauge Housing Security16 Gauge Tempered Glass 3-lamp I.S.

Steel Door Frame with Piano hinge

N: Minimum Security NS: Minimum UT: .125" Clear 17: T8 17W 347 04: Elect.T818 Gauge Housing Security 18 Gauge Polycarbonate with 4-lamp I.S.

Steel Door Frame .125" acrylic overlayPY: Pattern 12 .187" UNV Consult factorynominal Polycarbonate for other ballastVK: Pattern 12 . options140" AcrituffVX: Pattern 12.125" nominal Polycarbonate

Ordering Guide

Ordering GuideRV Guardsman Luminaire Lamp Catalogue- (Surface Box) Size NumberMaximum security 2 x 2 2-T8 RVX2SXDUS217

2 x 2 2-T8U6 RVX2SXDUS26UMedium Security 2 x 2 2-T8 RVD2SDSUT217

2 x 2 2-T8U6 RVD2SDSUT26UMinimum Security 2 x 2 2-T8 RVN2SNSPY217

2 x 2 2-T8U6 RVN2SNSPY26UVandal Resistant 2 x 2 2-T8 RVT2SFSVK217

2 x 2 2-T8U6 RVT2SFSVK26U

Ordering GuideRV Guardsman Luminaire Lamp Catalogue- (Surface Box) Size NumberMaximum security 1 x 4 2-T8 RVX1SXDUS232Medium Security 2 x 2 2-T8 RVD1SXDUT232Minimum Security 2 x 2 2-T8 RVN1SNSPY232Vandal Resistant 2 x 2 2-T8 RVT1SFSVK232

Ordering GuideRV Guardsman Luminaire Lamp Catalogue- (Surface Box) Size NumberMaximum security 2 x 4 2-T8 RVX2SXDUS232

2 x 4 3-T8 RVX2SXDUS3322 x 4 4-T8 RVX2SXDUS432

Medium Security 2 x 4 2-T8 RVXDSDSUT2322 x 4 3-T8 RVXDSDSUT3322 x 4 4-T8 RVXDSDSUT432

Minimum Security 2 x 4 2-T8 RVN2SNSPY2322 x 4 3-T8 RVN2SNSPY3322 x 4 4-T8 RVN2SNSPY432

Vandal Resistant 2 x 4 2-T8 RVT2SFSVK2322 x 4 3-T8 RVT2SFSVK3322 x 4 4-T8 RVX2SXDUS432

Page 121: LRG CFI

128

Features• Excellent for locations where vandal resistance is required.• Prismatic lens (VL) is 3/16" thick pattern 12, minimum impact

strength, 130 foot pounds.• Full perimeter gasketing (closed cell Neoprene) between door

frame and lens.• Tamper resistant holt head screws secure lens to housing.• 5" deep body, 2x2 and 2x4.• 74.4% efficient (T8), 2x4 4 lamp.• Hemmed over side rails for maximum safety.• Fixture ends turned-in for safe handling.• Built-in earthquake clips (patent no. 5,072,344), on 2x2 and 2x4.• Spring loaded rooster head latches.• 18 gauge steel hinges.• 69.3% efficient (T8), 2x2 2-6"U.• 62.2% efficient (T8), 1x4 2 lamp.

Options Page 520Ballast Specify voltage (120 or 277) and type and add as suffix, e.g. 120S0.Electrical/Wiring Options For special wiring, fusing, electronicdimming ballasts, consult factory.Seismic Hold-Down Clip For 1'x4' type G, Suffix: 2HD.Factory installed.Plaster Frame For F type troffers, order plaster frames separately.Catalog Number: PF24 for 2'x4' troffer; PF22 for 2'x2' troffer, PF14for 1'x4' troffer.Fusing Internal fast-blowing fusing. SUFFIX: GLR Internal slow-blowfusing. SUFFIX: GMF

BALLAST CODETYPE <20THD <10THDElectronic T8 SO* HI*1-3 Lamp T8 O3* H3*1-4 Lamp T8 O4* H4*1-3 Lamp TT5 40 Watt X3* I3*1&2 Lamp TT5 40 Watt SB* IB**Instant StartLens For optional 9/64" thick (VK) pattern 12, minimum impactstrength, 80 foot pounds, substitute VL with VK in Catalog No.i.e:GVS2GFSVK432.

128

0°30°

60°

90°

1200

800

400

0°30°

60°

90°

1200

400

800

0°30°

60°

90°

2000

3000

1000

21 31/32"

24 7/8"

23 5/8"

24"

24 1/4

25 1/2

4 1/4"

21 31/32"

24 7/8"

23 5/8"

4 1/4"

1

2

34

5

67

48"

48 1/4"

49 1/2"

4 1/4"

5

8

SPECIALAPPLICATIONS

Special Application luminaireRV Guardsman Recessed 1’x 4’, 2’x 2’, 2’x 4’ (RV)Recessed Grid and Flange Security for High Abuse Applications

Features:• Post painted 14-20 gauge CRS body• Overlapped and welded corners• Door frame secured by piano hinge and 4 TORX scres• One piece CRS door frame in 14-20 gauge CRS• Lens retained by one piece inner frame• Choice of prismatic acrylic, Prismatic polycarbonate or clear tem-

pered glass• 14 gauge cold rolled steel (maximum security)• 16 gauge cold rolled steel (medium security)• 18 gauge cold rolled steel (minimum security)

OptionsBallast Specifiy voltage (120,277 or 347v) and add suffix e.g.(120SO)Magnetic ElectronicT8:OC 1 or 2 LPB T8: SO

3 LPB T8:O34 LPB T8:O4

LPB: Number of lamps per ballastElectrical/Wiring Options:Consult factory

RVX1FXDUS232120SO

RCR C. U.1 532 493 454 425 396 357 338 319 2810 25

RVX2SXDUS26U120SO

RCR C. U.1 582 543 504 455 426 397 368 339 3110 28

RVX2FXDUS432120O4

RCR C. U.1 572 533 494 455 426 397 358 339 3010 29

Page 122: LRG CFI

129

Special Applications Luminaires

Reference Data

Efficiency 47.20%Spacing Ratio 1.2

Electronic Ballast

Input Watts (120V) 62.0WBallast Factor 0.88

Reference Data

Efficiency 52.10%Spacing Ratio 1.2

Electronic Ballast

Input Watts (120V) 60.0WBallast Factor 0.88

Reference Data

Efficiency 50.90%Spacing Ratio 1.2

Electronic Ballast

Input Watts (120V) 112.0WBallast Factor 0.88

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 10'

8' x 8' (64 sq ft/luminaire) 27.8 0.71

12' x 16 x 10'

6' x 8' (48 sq ft/luminaire) 30.7 1.23

8' x 8' x 10'

8' x 8' (64 sq ft/luminaire) 32.8 1.85

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 10'

8' x 8' (64 sq ft/luminaire) 33.1 0.79

12' x 16 x 10'

6' x 8' (48 sq ft/luminaire) 31.6 1.21

8' x 8' x 10'

6' x 8' (48 sq ft/luminaire) 33.5 1.81

Application Data*

Luminaire Spacing FC VCP W/Sq Ft

50' x 70' x 10'

8' x 10' (80 sq ft/luminaire) 59.8 1.26

8' x 8' x 10'

6' x 8' (48 sq ft/luminaire) 32.9 1.09

Ordering Guide

Ordering Guide

Ordering Guide

Luminaire Size Lamp Catalogue Number

Maximum Security 1x4 2-T8 RVX1SXDUS232Maximum Security 1x4 2-T8 RVX1FXDUS232Medium Security 1x4 2-T8 RVD1FXDUT232Minimum Security 1x4 2-T8 RVN1FNSPY232

1x4 2-T8 RVN1GNSPY232Vandal Resistant 1x4 2-T8 RVT1FFSVK232

1x4 2-T8 RVT1GFSVK232

Luminaire Size Lamp Catalogue Number

Maximum Security 2x2 2-T8 RVX2FXDUS2172x2 2-T8U6 RVX2FXDUS26U

Medium Security 2x2 2-T8 RVD2FDSUT2172x2 2-T8U6 RVD2FDSUT26U

Minimum Security 2x2 2-T8 RVN2FNSPY2172x2 2-T8U6 RVN2FNSPY26U2x2 2-T8 RVN2GNSPY2172x2 2-T8U6 RVN2GNSPY26U

Vandal Resistant 2x2 2-T8 RVT2FFSVK2172x2 2-T8U6 RVT2FFSVK26U2x2 2-T8 RVT2GFSVK2172x2 2-T8U6 RVT2GFSVK26U

Luminaire Size Lamp Catalogue Number

Maximum Security 2x4 2-T8 RVX2FXDUS2322x4 3-T8 RVX2FXDUS3322x4 4-T8 RVX2FXDUS432

Medium Security 2x4 2-T8 RVXDSDSUT2322x4 3-T8 RVXDSDSUT3322x4 4-T8 RVXDSDSUT432

Minimum Security 2x4 2-T8 RVN2FNSPY2322x4 3-T8 RVN2FNSPY3322x4 4-T8 RVN2FNSPY4322x4 2-T8 RVN2GNSPY2322x4 3-T8 RVN2GNSPY3322x4 4-T8 RVN2GNSPY432

Vandal Resistant 2x4 2-T8 RVT2FFSVK2322x4 3-T8 RVT2FFSVK3322x4 4-T8 RVT2FFSVK4322x4 2-T8 RVT2GFSVK2322x4 3-T8 RVT2GFSVK3322x4 4-T8 RVT2GFSVK432

*Average Footcandles Maintained Total LLF=.82 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens

RV X 2 F XD US 4 32 120 04Luminaire Luminaire Luminaire Mounting Door Frame Lens/Shielding Lamp Quantity Lamp/Type Voltage Ballast OptionsType Gauge Width Style in a luminaire

cross-sectionRV SERIES X: Maximum 14 1: Nominal 12" G: Std. T-Bar XD: Maximum US: .250" Clear 2: 2 lamps 32: T8 32W 120 SO: Elect.T8 Consult

Gauge Housing Security 14 Gauge Polycarbnoate with 3: 3 lamps 1-2 lamp I.S factoryDouble Door Frame .125" acrylic overlay 4: 4 lampswith Piano hinge

D: Medium Security 2: Nominal 24" F: Flanged for DS: Medium CG: Pattern 73 277 03: 3 LPB T816 Gauge Housing Drywall Security 16 Gauge .140" Tempered Glass Electronic

Steel Door Frame with Piano hinge

N: Minimum Security NS: Minimum UT: .125" Clear 347 04: 4 LPB T818 Gauge Housing Security 18 Gauge Polycarbonate with Electronic

Steel Door Frame .125" acrylic overlayPY: Pattern 12 UNV Consult factory.187" nominal for other ballastPolycarbonate optionsVK: Pattern 12 .140" AcrituffVX: Pattern 12 .125" nominal Polycarbonate

Ordering Guide

Page 123: LRG CFI

130

Features• Excellent for locations where vandal resistance is required.• Prismatic lens (VL) is 3/16" thick pattern 12, minimum impact

strength, 130 foot pounds.• Full perimeter gasketing (closed cell Neoprene) between door

frame and lens.• Tamper resistant holt head screws secure lens to housing.• 5" deep body, 2x2 and 2x4.• 74.4% efficient (T8), 2x4 4 lamp.• Hemmed over side rails for maximum safety.• Fixture ends turned-in for safe handling.• Built-in earthquake clips (patent no. 5,072,344), on 2x2 and 2x4.• Spring loaded rooster head latches.• 18 gauge steel hinges.• 69.3% efficient (T8), 2x2 2-6"U.• 62.2% efficient (T8), 1x4 2 lamp.

Options Page 520Ballast Specify voltage (120 or 277) and type and add as suffix, e.g. 120S0.Electrical/Wiring Options For special wiring, fusing, electronicdimming ballasts, consult factory.Seismic Hold-Down Clip For 1'x4' type G, Suffix: 2HD.Factory installed.Plaster Frame For F type troffers, order plaster frames separately.Catalog Number: PF24 for 2'x4' troffer; PF22 for 2'x2' troffer, PF14for 1'x4' troffer.Fusing Internal fast-blowing fusing. SUFFIX: GLR Internal slow-blowfusing. SUFFIX: GMF

BALLAST CODETYPE <20THD <10THDElectronic T8 SO* HI*1-3 Lamp T8 O3* H3*1-4 Lamp T8 O4* H4*1-3 Lamp TT5 40 Watt X3* I3*1&2 Lamp TT5 40 Watt SB* IB**Instant StartLens For optional 9/64" thick (VK) pattern 12, minimum impactstrength, 80 foot pounds, substitute VL with VK in Catalog No.i.e:GVS2GFSVK432.

130

0°30°

60°

90°

500

1000

1500

0°30°

60°

90°

600

1200

1800

0°30°

60°

90°

1250

2500

3750

4-3/4"(44.4mm)

12" (304.8mm)

5" (127mm)

24" (610mm)

5"(127mm)

24" (610mm)SPECIALA

PPLICATIONS

Special Application LuminaireGuardsman Series - Recessed 1’x 4’, 2’x 2’, 2’x 4’ (GVS)Recessed Security for Vandal Resistant Applications

Features• Excellent for locations where vandal resistance is required.• Prismatic lens (VL) is 3/16" thick pattern 12, minimum impact

strength, 130 foot pounds.• Full perimeter gasketing (closed cell Neoprene) between door

frame and lens.• Tamper resistant holt head screws secure lens to housing.• 5" deep body, 2x2 and 2x4.• 74.4% efficient (T8), 2x4 4 lamp.• Hemmed over side rails for maximum safety.• Fixture ends turned-in for safe handling.• Built-in earthquake clips (patent no. 5,072,344), on 2x2 and 2x4.• Spring loaded rooster head latches.• 18 gauge steel hinges.• 69.3% efficient (T8), 2x2 2-6"U.• 62.2% efficient (T8), 1x4 2 lamp.

Options page 150-156Ballast Specify voltage (120 or 277) and type and add as suffix, e.g. 120S0.Electrical/Wiring Options For special wiring, fusing, electronicdimming ballasts, consult factory.Plaster Frame For F type troffers, order plaster frames separately.Catalog Number: FK92X4 for 2'x4' troffer; FK92X2 for 2'x2' troffer,FK91X4 for 1'x4' troffer.Fusing Internal fast-blowing fusing. SUFFIX: F

BALLAST CODETYPE <20THD <10THDElectronic T8 SO* HI*1-3 Lamp T8 O3* H3*1-4 Lamp T8 O4* H4*1-3 Lamp TT5 40 Watt X3* I3*1&2 Lamp TT5 40 Watt SB* IB**Instant StartLens For optional 9/64" thick (VK) pattern 12, minimum impactstrength, 80 foot pounds, substitute VL with VK in Catalog No.i.e:GVS2GFSVK432.

GVS1GFSVL232120S0

RCR C. U.1 682 633 584 535 496 467 438 409 3710 35

GVS2GFSVL26U120S0

RCR C. U.1 762 703 654 605 556 517 488 449 4210 39

GVS2GFSVL432120S0

RCR C. U.1 822 753 694 645 596 557 518 479 4410 42

Page 124: LRG CFI

GVS1GFSVL232 120 SO

GVS2GFSVL26U 120 SO

GVS2GFSVL432 120 04

131*Average Footcandles Maintained Total LLF=.82 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens

Recessed Fluorescent Luminaires

Reference Data

Efficiency 62.2%Spacing Ratio 1.2

Electronic Ballast

Input Watts (120V) 62.0WBallast Factor 0.88

Application Data*

Luminaire Spacing FC W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 41.1 0.81

8' x 10' (80 sq ft/luminaire) 35.9 0.71

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 42.5 1.23

Fixture size Lamps Exposed Flanged forWideqty/type T-Grid Dry or Plaster

1 x 4 2-T8 GVS1GFSVL232 GVS1FFSVL232Flat Steel Door

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :120 See page 130 See page 130277

Reference Data

Efficiency 69.3%Spacing Ratio 1.2

Electronic Ballast

Input Watts (120V) 60.0WBallast Factor 0.88

Application Data*

Luminaire Spacing FC W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 49.7 0.87

8' x 10' (80 sq ft/luminaire) 38.6 0.68

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 45.8 1.18

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :120 See page 130 See page 130277

Fixture size Lamps Exposed Flanged forWideqty/type T-Grid Dry or Plaster

2 x 2 2-6” T8 GVS2GFSVL26U GVS2FFSVL26UFlat Steel Door 3-TT5 GVS2GFSVL3FT GVS2FFSVL3FT

3-1.6”U T8 GVS2GFSVL32U GVS2FFSVL32U

Reference Data

Efficiency 74.4%Spacing Ratio 1.2

Electronic Ballast

Input Watts (120V) 112.0WBallast Factor 0.88

Application Data*

Luminaire Spacing FC W/Sq Ft

50' x 70' x 8.5' Space

8' x 10' (80 sq ft/luminaire) 86 1.26

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 50.7 1.10

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :120 See page 130 See page 130277 Add appropriate

suffix to catalog no., ie: (GLR)

Fixture size Lamps Exposed Flanged forWideqty/type T-Grid Dry or Plaster

2 x 4 2- T8 GVS2GFSVL232 GVS2FFSVL232Flat Steel Door 3- T8 GVS2GFSVL332 GVS2FFSVL332

4- T8 GVS2GFSVL432 GVS2FFSVL432

Page 125: LRG CFI

132

0°30°

60°

90°

500

1000

1500

0°30°

60°

90°

450

900

1350

0°30°

60°

90°

1050

2100

3150

12" (305mm)

5-1/2"(140mm)

24" (610mm)

5-1/2"(140mm)

24" (610mm)

5-1/2"(140mm)

SPECIALAPPLICATIONS

Special Application LuminaireGuardsman series - Surface 1’x 4’, 2’x 2’, 2’x 4’ (GVB)Surface Security for Vandal resistant Applications

Features• Excellent for locations where vandal resistance is required.• 20 gauge steel body.• Prismatic lens (VL) is 3/16" thick, pattern 12, minimum impact

strength, 130 foot pounds.• Full perimeter gasketing (closed cell Neoprene) between door frame

and lens.• Tamper resistant holt head screws secure lens to housing.• 45° mitered corners (body and door frame).• Only 5-1/2" deep.• 54.9% efficient (2 lamp T8).1x4• Side mounted ballast for cooler operation. 1x4• Fully enclosed wiring.• 55.5% efficient (2U lamp T8).• Side mounted ballast for cooler operation. 2x2• 65.2% efficient (4 lamp T8).• Side mounted ballast for cooler operation. 2x4

Options page 150-156Ballast Specify voltage (120 or 277) and type and add as suffix, e.g.120SO.

Electrical/Wiring Options For special wiring, fusing, electronicdimming ballasts, or emergency pack, consult factory.

Fusing Internal fast-blowing fusing. SUFFIX: F

BALLAST CODETYPE <20THD <10THDElectronic T8 SO* HI*1-3 Lamp T8 O3* H3*1-4 Lamp T8 O4* H4*Electronic TT5 (40 Watt) SB* IB*1-3 Lamp TT5 (40 Watt) X3* I3** Instant start

Lens: For optional 9/64” thick (VK) pattern 12, minimum impact strength 80 foot pounds, substitute VL with VK incatalog no. ie GVB2SFSVK432

GVB1SFSVL232120S0

GVB2SFSVL26U120S0

GVB2SFSVL43212004

RCR C. U.1 602 563 514 485 446 417 388 369 3310 31

RCR C. U.1 612 563 524 485 446 417 388 369 3310 31

RCR C. U.1 722 663 604 565 526 487 448 419 3910 36

Page 126: LRG CFI

GVB1SFSVL232

GVB2SFSVL26U

GVB2SFSVL432

120

120

120

SO

SO

04

133* Pieds-bougies moyens maintenus. LLF Total = .75 Réflectivité : Plafond :80% mur : 50% plancher : 20%. Lampe de type RE835 évaluée à 3000 lumens.

Special Application Luminaires

Reference Data

Efficiency 54.9%Spacing Ratio 1.2

Electronic Ballast

Input Watts (120V) 62.0WBallast Factor 0.88

Reference Data

Efficiency 55.5%Spacing Ratio 1.2

Electronic Ballast

Input Watts (120V) 60.0WBallast Factor 0.88

Reference Data

Efficiency 65.2%Spacing Ratio 1.2

Electronic Ballast

Input Watts (120V) 112.0WBallast Factor 0.88

Application Data*

Luminaire Spacing FC W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (48 sq ft/luminaire) 41.3 0.86

8' x 10' (80 sq ft/luminaire) 32.1 0.67

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 39.2 1.16

Application Data*

Luminaire Spacing FC W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 40.1 0.94

8' x 10' (80 sq ft/luminaire) 21.2 0.73

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 56.8 1.9

Application Data*

Luminaire Spacing FC W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 97.5 1.75

8' x 10' (80 sq ft/luminaire) 75.9 1.36

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 68.6 1.77

Fixture size Lamps Surfaceqty/type Box

1 x 4 2-T8 GVB1SFSVL232Flat Steel Door

Fixture size Lamps Surfaceqty/type Box

2 x 2 2-6” T8 GVB2SFSVL26UFlat Steel Door 3-TT5 GVB2SFSVL3FT

3-1.6”U T8 GVB2SFSVL32U

Fixture size Lamps Surfaceqty/type Box

2 x 4 2- T8 GVB2SFSVL232Flat Steel Door 3- T8 GVB2SFSVL332

4- T8 GVB2SFSVL432

Ordering Guide

Ordering Guide

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :120 See page 132 See page 132277

Basic catalogue number : Voltage : Ballast : Options :120 See page 132 See page 132277

Basic catalogue number : Voltage : Ballast : Options :120 See page 132 See page 132277

Page 127: LRG CFI

134

0°30°

60°

90°

0°30°

60°

90°

0°30°

60°

90°

2 7/8"(73mm)

10 5/16" (262mm)

2-7/8"(73mm)

15-5/16" (389mm)

2-7/8"(73mm)

15-5/16" (389mm)SPECIALA

PPLICATIONS

Special Application LuminaireGuardsman Series - Wrap Surface 4’, 8’ (GVW)Surface Vandal Wrap security for Vandal resistant Applications

Features• Excellent for locations where vandal resistance is required.• Prismatic lens is 50% DR (impact resistant), and 50% standard

acrylic with a nominal thickness of 1/8", withstands 70 ft. lbs.impact without breaking.

• Tamper resistant holt head screws secure lens to housing.• UL-Listed for direct mounting on low density ceilings and damp

locations.• Steel end caps, standard.• Self-aligning for continuous row mounting.• Heavy duty, die formed channel of code gauge steel.

Options page 150-156Ballast Specify voltage (120 or 277) and type and add as suffix, e.g.120SO.

BALLAST CODETYPE <20THD <10THDElectronic T8 SO* HI*1-3 Lamp T8 O3* H3*1-4 Lamp T8 O4* H4** Instant Start

Electrical/Wiring Options For special wiring, fusing, electronic dim-ming ballasts, consult factory.

Fusing Internal fast-blowing fusing. SUFFIX: F

GV4WA232120SO

GV4WB332120O3

RCR C. U.1 912 823 764 685 646 587 548 509 4610 40

RCR C. U.1 852 783 714 665 606 567 528 479 4510 41

GV4WB432120O4

RCR C. U.1 832 773 704 655 596 557 518 479 4510 41

Page 128: LRG CFI

GV4WA232

GV4WB332

GV4WB432

120

120

120

SO

SO

SO

135* Pieds-bougies moyens maintenus. LLF Total = .75 Réflectivité : Plafond :80% mur : 50% plancher : 20%. Lampe de type RE835 évaluée à 3000 lumens.

Fluorescent WraparoundLuminaires

Reference Data

Efficiency 65.0%Spacing Ratio 1.2

Electronic Ballast

Input Watts (120V) 62.0WBallast Factor 0.88

Reference Data

Efficiency 75.4%Spacing Ratio 1.2

Electronic Ballast

Input Watts (120V) 85.0WBallast Factor 0.88

Reference Data

Efficiency 70.1%Spacing Ratio 1.4

Electronic Ballast

Input Watts (120V) 112.0WBallast Factor 0.88

Application Data*

Luminaire Spacing FC W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 55.9 1.36

30' x 30' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 55.3 1.52

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 49.4 1.78

Application Data*

Luminaire Spacing FC W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 91 2.27

30' x 30' x 8.5' Space

8' x 8' (48 sq ft/luminaire) 92.8 2.61

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 41.4 1.53

Application Data*

Luminaire Spacing FC W/Sq Ft

50' x 70' x 8.5' Space

8' x 8' (64 sq ft/luminaire) 100.2 2.52

30' x 30' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 115.6 3.27

12' x 16' x 8.5' Space

6' x 8' (48 sq ft/luminaire) 77.6 2.28

Width Length Lamp Type/Qty Surface Wraparound10 5/16” 48” 2-T8 GV4WA23210 5/16” 96” 2-T8 in Tandem (4 total) GV8WA232

Width Length Lamp Type/Qty Surface Wraparound15 5/16” 48” 3-T8 GV4WB332

Width Length Lamp Type/Qty Surface Wraparound15 5/16” 48” 2- T8 GV4WB23215 5/16” 48” 4- T8 GV4WB432

Ordering Guide

Ordering Guide

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :120 See page 134 See page 134277

Basic catalogue number : Voltage : Ballast : Options :120 See page 134 See page 134277

Basic catalogue number : Voltage : Ballast : Options :120 See page 134 See page 134277

Page 129: LRG CFI

136

0°30°

60°

90°

400

800

1200

3-7/8"(98mm)

6"(152mm)

SPECIALAPPLICATIONS

Special Application LuminaireGuardsman Series - Wrap Surface 2’, 4’ (GSW)Surface Vandal Wrap Security for Vandal Resistant Applications

Features• Excellent for locations where vandal resistance is required, areas

such as hallways, stairwells, locker rooms, parking garages andpsychiatric hospitals.

• For ceiling or wall mounted applications.• Can be vertically or horizontally mounted on wall.• 20 gauge cold rolled steel, post painted, baked white enamel

housing.• 18 gauge cold rolled steel post painted baked white enamel end

caps, standard.• Linear prismatic lens 50% DR (impact resistant) and 50% standard

acrylic with nominal thickness of 1/8", withstands 70 ft lbs impactwithout breaking.

• Tamper resistant holt head screws secure ends to housing.• Only 3-7/8" deep, meets American with Disabilities Act for wall

mounted fixtures.• Nominal 2' and 4' lengths.• 73.9% efficient (T8 lamps).

Options page 150-156

Ballast Specify voltage (120, 277or UNV) and type and add as suffix,e.g. 120SO.

BALLAST CODETYPE <20THD <10THDElectronic T8 SO* HI**Instant Start

Electrical/Wiring Options For special wiring, fusing, electronic dim-ming ballasts, consult factory.

Fusing Internal fast-blowing fusing. SUFFIX: F

GSW4232120S0

RCR C. U.1 812 733 664 615 566 517 488 449 4110 39

Page 130: LRG CFI

GSW4232 120 SO

137*Average Footcandles Maintained Total LLF=.82 Reflectance: 80% Ceiling, 50% Wall, 20% Floor RE835 lamp rated at 3000 lumens

Ceiling or Wall-Mounted Fluorescent

Reference Data

Efficiency 73.9%Spacing Ratio 1.3

Electronic Ballast

Input Watts (120V) 62.0WBallast Factor 0.88

Application Data*

Luminaire Spacing FC W/Sq Ft

4' W x 40' L x 8.5' H Corridor

8' center (single row) 50.1 1.73

6' W x 40' L x 8.5' H Corridor

8' center (single row) 41.5 1.15

8' W x 40' L x 8.5' H Corridor

4' x 8' (32 sq ft/luminaire) 70.3 1.73

Basic catalogue number : Voltage : Ballast : Options :GSW Series 120 See page 136 See page 136

277UNVUniversalVoltage 120-277T8

End Cap End Cap

Nut Nut

Nut

ThreadedNipple

Requiredto spacefixtures

apart so endscan be

removed orinstalled.

Type Fixture Lamp Lamp CatalogLength Length Type / Qty Number

GSW 23- 15/16” 2' 1-T8 GSW2117Vandal 23- 15/16” 2' 2-T8 GSW2217Resistant 48" 4' 1-T8 GSW4132Ceiling or Wall 48” 4' 2-T8 GSW4232

Ordering Guide

4"(102mm)

6"(152mm)

24"(610mm)

48"(1219mm)

4" (102mm)6" (152mm)

23-15/16"(608mm)

7/8" dia. K.O. (2) 9/32" hole (2)

7/8" dia. K.O. (3)9/32" hole (2) 1-7/8" dia. K.O.

For continuous row mounting(supplied by others).

Page 131: LRG CFI

48" (1219 mm)

6-7/8"(175 mm)

Ceiling

Wall

Wallangle

or T-barby others

Wall

48" (1219 mm)

Acoustical tile by others

Secure Luminaire(4 Places)

24" (610 mm)

6-7/8"(175 mm)

Wall

Ceiling

Wall

Wallangle

or T-barby others 24" (610 mm)

Acoustical tileby others

Secure Luminaire(4 Places)

138

Sequential switch (SW)

Medical LuminairesMD*4 Series 2’x 2’, 2’x 4’ (MD4)Multi-Function Patient Room Luminaire • Ambient / Reading / Examination / Nurse’s Night Light

MD*4 combines all of the lighting functions in a patient’s room in asingle luminaire that is ceiling mounted to permit clean headwalls. Thisenables architects and interior designers to create a more home-likeenvironment and moves the light luminaire off the wall, a location whereit can be damaged easily or interfere with medical equipment. MD*4 ismore efficient and more economical than all other patient lighting systems.

Features•2 x 4 Unit has four lighting functions with integral ambient,

reading, examination and optional nurse’s night light.•2 x 2 Unit has three lighting functions with integral ambient,

reading, and optional nurse’s night light.•Specular aluminum reflectors for precise light control and glare free

patient environment.•Installs as a one-piece unit. Recessed or surface mounted to ceiling

against wall directly behind patient. Eliminates damage to luminairefrom hospital equipment attached to patient bed.

•6-7/8” deep.•Top wiring access plate is standard.•All lamps are enclosed.•All TT5 type lamps (not included) are accessible for relamping

without tools.•Rugged 20 gauge steel housing.•Optional low voltage (1-3 volts) electronic sequential switch mounted

in luminaire for ambient and reading light controlled with pillowswitch (by others).

•Examination Light in 2 x 4 has 36 cell specular aluminum paraboliclouver with pattern 12 lens overlay.

Options pages 150-156Electronic (Low Voltage) Sequential Switch Switch factorymounted in luminaire for ambient and reading light convenience(controlled by pillow switch, by others). Suffix: SW. (N/A 347V)Nurse Night Light 120V medium base, narrow spot, 50W PAR 20reflector lamp included with specular anodized mirror, field adjustableto right or left side of patients bed. Suffix: NL.Fusing Suffix: F.Electrical/Wiring Options Consult factory.Tamper Proof Consult factory.Germ Guard Order Catalogue No., MD4CLGS24.

MEDICAL

MD4 2’x 4’

Wall

Ceiling

Secure Luminaire(4 Places)

Acoustical tile by othersWall

Wallangle

or T-barby others

MD2 2’x 2’(2 types of lighting : ambient / reading)

Ceiling

Wall

Secure Luminaire(4 Places)

Acoustical tile by othersWall

Wallangle

or T-barby others

Page 132: LRG CFI

MD4GPSVA2BX4 1 SW NL

MD2G2BX 120 SW NL

139

WAL

L

Medical Luminaires

BED BED

Illumination at the reading task ranges 50-60 footcandles

Ambient Light/On Adjacent MD*4/Off

Footcandles on Beds

Reading Light/On

Wall

Reading Light/On Adjacent MD*4 Off

WALL

BED BED

Numbers in parenthesis ( ) are total footcandle level of ambient and reading lights only.

Ordering Guide

Basic catalogue number : Voltage : Options : Options : Options :Multi-function 1=120 Electronic Nurses See page 138Examination Luminaire 2=277 Sequential Night Add appropriate

3=347 Switch Light suffix to cataloguenumber

Type Ballast Number Gridtype of lamps ceiling

MD*2 40W Electro-magnetic 2-TT5 MD2G2BX2'x2' 40W Electronic 2-TT5 MD2G2SBwithAmbient,andReadingLight

Ordering Guide

Reading LightEliminates reflected glare from reading material (over the shoulder illumination).No direct glare to patient or visitors. (7 footcandles maximum at head of bed.15 footcandles maximum at foot of bed.)Controls light directly onto patients bed.No reading light spill-over to adjacent beds. (1 footcandle maximum at head ofadjacent patient’s bed.)

Illumination at the reading task ranges 50-80 footcandles.

Ambient LightIndirect illumination from wall directly behind patient provides glare-free lighting.No direct glare to patient (Light is directed towards wall.)No direct glare to patients visitor.No direct glare to adjacent patients. (3 footcandles maximum on wall behind adjacentpatient’s bed.)

Examination LightExcellent colour rendition. (82 CRI TT5 Type lamp)Wired for independent switching (1 or 2 circuit).

Reading LightEliminates reflected glare from reading material(over the shoulder illumination).No direct glare to patient or visitor. (7 footcandlesmaximum at head of bed. 15 footcandles maximum atfoot of bed.)Controls light directly onto patients bed.No reading light spill-over to adjacent beds. (1 footcandlemaximum at head of adjacent patient’s bed.)

Footcandles on Bed(Horizontal)

Basic catalogue number : Voltage : Options : Options : Options :Multi-function 120 Electronic Nurses See page Patient Luminaire 277 Sequential Night 138

347 Switch Light Add appropriatesuffix tocataloguenumber

Footcandles on Bed (with Specular Louver)(Totals of Ambient, Reading and examination lights)

Type Examination Total qty Ballast Gridlight shielding of lamps* type ceiling

MD*4 36 Cell 6-TT5 40W Electro-mag. MD4GPSVA2BX42'x4' Low Iridescence 6-TT5 40W Electronic MD4GPSVA2SB4with Specular Louver 5-TT5 40W Electro-mag. MD4GPSVA2BX3Ambient, with Prismatic 5-TT5 40W Electronic MD4GPSVA2SB3Reading OverlayandExaminationLight

*Include 2-TT5 for ambiant / reading section.BED

Adjacent MD*4 Off

Page 133: LRG CFI

6-7/8"(175 mm)

6-7/8"(175 mm)

48" (1219 mm)

24" (610 mm)

140

Luminaire fixé en 4 points

Medical LuminairesMD* Coffer 2’x 2’, 2’x 4’ (MDC)Multi-Function Patient Room Luminaire • Ambient / Reading / Examination / Nurse’s Night Light

MD*Coffer combines all of the lighting functions in a patient’s roomin a single luminaire that is ceiling mounted to permit clean headwalls.This enables architects and interior designers to create a more home likeenvironment and moves the light luminaire off the wall, a location whereit can be damaged easily or interfere with medical equipment.MD*Coffer is more efficient and more economical than all other patientlighting systems.

Features•2 x 4 Unit has four lighting functions with integral ambient,

reading, examination and optional nurse’s night light.•2 x 2 Unit has three lighting functions with integral ambient,

reading, and optional nurse’s night light with perforated mesh shield.•Specular aluminum reflectors for precise light control and glare free

patient environment.•Installs as a one-piece unit. Recessed or surface mounted to ceiling

against wall directly behind patient. Eliminates damage to luminairefrom hospital equipment attached to patient bed.

•Top wiring access plate is standard.•All TT5 type lamps (not included) are accessible for relamping

without tools. All lamps are enclosed.•Rugged 20 gauge steel housing.•Optional low voltage (1-3 volts) electronic sequential switch mounted

in luminaire for ambient and reading light controlled with pillowswitch (by others).

•Examination Light in 2 x 4 has 36 cell flat white baked enamellouver with pattern 12 lens overlay.

•Perforated mesh shield for ambient / reading section.

Options pages 150-156347 Volt — Change 120 to 347 (e.g. MDCGWSVA2BX4BX120,MDCGWSVA2BX4BX347).Electronic (Low Voltage) Sequential Switch Switch factorymounted in luminaire for ambient and reading light convenience(controlled by pillow switch, by others). Suffix: SW. (N/A 347V)9/7 Watt Night Light Suffix: PL (Lamp not included).Fusing Suffix: F.Electrical/Wiring Options Consult factory.Tamper Proof Consult factory.Germ Guard Order Catalogue No., MD4CLGS24.

PL9 or PL7 Night Light (PL)(Lamps not included)

Sequential switch (SW)

MEDICAL

Ceiling

MD*Coffer 2’x 4’

MD*Coffer 2’x 2’(2 types of lighting : ambient / reading)

Mount12” - 18”from wallWall

9’6” max.mounting height

9’6” max.mounting height

Accoustical tile (by others)

Accoustical tile (by others)

WallMount

12” - 18”from wall

Wallangleor T-bar(byothers)

Mount12” - 18”from wallWall

Ceiling

9’6” max.mounting height

9’6” max.mounting height

Accoustical tile (by others)

Secure luminaire(4 places)

Accoustical tile (by others)

WallMount

12” - 18”from wall

Wallangleor T-bar(byothers)

Page 134: LRG CFI

MDCGWSVA2BX4 1 SW NL

MDCG2BX 120 SW NL

141

14 15 15 14 12 12 7

14 16 16 14 12 12 8

14 15 15 14 12 12 7

17 21 23 28 33 6 5

18 22 24 29 35 6 5

17 21 23 28 33 6 5

12"

12"12"

68 85 93 99 100 65 49(31) (36) (38) (42) (45) (18) (12)

73 89 99 104 106 68 53(32) (38) (40) (43) (47) (18) (13)

68 85 93 99 100 65 49(31) (36) (38) (42) (45) (18) (12)

3"6" 12"

3"6" 12"

3" 6" 12"

3"6" 12"

12"14 15 15 14 12 12 7

14 16 16 14 12 12 8

14 15 15 14 12 12 7

3"6" 12"

17 21 23 28 33 6 5

18 22 24 29 35 6 5

17 21 23 28 33 6 5

12"3"

6" 12"

12"

3 4 3 3 2 2 1

3 4 3 3 2 2 1

3 4 3 3 2 2 1

Lighted Zone

Wall

Bed

FOOTCANDLES ON BED

AMBIENT LIGHTIndirect illumination from TT5 shielded by perforated mesh shield with white acrylic overlay.No direct glare to patient. No direct glare to patients visitor. No direct glare toadjacent patients.

LightedZone

Wall

BedIllumination at the reading taskranges 45-50 footcandles.

FOOTCANDLES ON BED

READING LIGHTEliminates reflected glare from reading material (over shoulder illumination).No direct glare to patient or visitors. Controls light directly onto patient’s bed.

Lighted Zone

LightedZone

Wall

Bed

Wall

FOOTCANDLES ON BED

BedIllumination at the reading taskranges 45-50 footcandles.

AMBIENT LIGHTIndirect illumination from TT5 shielded by perforated mesh shield with white acrylic overlay.No direct glare to patient. No direct glare to patients visitor. No direct glare toadjacent patients.

FOOTCANDLES ON BED

READING LIGHTEliminates reflected glare from reading material (over shoulder illumination).No direct glare to patient or visitors. Controls light directly onto patient’s bed.

Medical Luminaires

Type Examination Total qty Ballast Gridlight shielding of lamps* type ceiling

MD*Coffer 36 Cell 6-TT5 40W Electro-mag. MDCGWSVA2BX42' x 4' with white 6-TT5 40W Electronic MDCGWSVA2SB4Ambient, louver 5-TT5 40W Electro-mag. MDCGWSVA2BX3Reading with Prismatic 5-TT5 40W Electronic MDCGWSVA2SB3and OverlayExaminationLight

Ordering Guide

Basic catalogue number : Voltage : Options : Options : Options :Multi-function 1=120 Electronic Nurses See page 140Examination Luminaire 2=277 Sequential Night Add appropriate

3=347 Switch Light suffix tocataloguenumber

*Include 2-TT5 for ambiant / reading section.

LightedZone

Wall

Bed

EXAMINATION LIGHTExcellent colour rendition. Wiredfor independent switching(1 or 2 circuit). Optional louveror lens frame. Concealed hingingand latching.

FOOTCANDLES ON BEDTotals of ambient, reading and examination lights.Numbers in parenthesis ( ) are total footcandle level ofambient and reading lights only.

Type Ballast Number Gridtype of lamps ceiling

MD*Coffer 40W Electro-magnetic 2-TT5 MDCG2BX2' x 2' 40W Electronic 2-TT5 MDCG2SBwithAmbient,andReadingLight

Ordering Guide

Basic catalogue number : Voltage : Options : Options : Options :Multi-function 120 Electronic Nurses See page 140Patient Luminaire 277 Sequential Night Add appropriate

347 Switch Light suffix tocataloguenumber

Bed

Wall

NIGHT LIGHT (Optional)Indirect 9 or 7 watt PL lamp shielded by perforated mesh with internal white acrylicoverlay. No glare to any patient. Wired for independent switching.

FOOTCANDLES ON BED

Page 135: LRG CFI

24" (610 mm)

5"(127 mm)

60°

30°

3025

2000

1000

0

30°

60°

24" (610 mm)

5"(127 mm)

3000

60°

30°

4252

2000

1000

0

30°

60°

142

Medical LuminairesSUS 432 / 632 2’x 4’Operating Room Luminaire

Features•Asymmetric/symmetric distribution provides:

Supplemental illumination to operating tables.Minimizes contrast between surgical and surrounding areas.

•Meets government specification for Radio Frequency Interference (RFI),MIL-STD 461-A, MIL-STD 463.

•One radio suppressor per luminaire (standard).•High efficiency 60.9% (6 light), 61.2% (4 light).•One-piece housing is embossed construction for added strength.•Built-in hold-down clips.•Flat full-size steel lens frame is gasketed.•Black housing exterior for cooler ballast operating temperature.•Turned-in edges for safe handling.

Options pages 150-156Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SO.Magnetic Electronic PowerSpec DimmingT8: OC T8: SO T8: PS

2 x 3 LPB T8: O6 (not avail. in 347V)4 LPB T8: O4

For T12 lamp see page 151.LPB : Number of lamps per ballast.Continuous Row Installation For F type luminaires, half-widthflanges are required between luminaires. Catalogue number FK92X4-CRM.Plaster Frames F type luminaires do include plaster frames. G typeluminaires require FK92X4 universal frame kit.Electrical/Wiring Options Consult Factory.Fusing Internal fast-blow fusing. Suffix: F.Radio Interference Filter 120, 277 or 347 volt, 50 or 60 Hz. Suffix: R.

MEDICAL

SUS2GFSMA632120O6 (Data)

SUS2GFSMA432120O4 (Data)

RCR C. U.1 642 563 504 455 406 367 338 309 2810 25

RCR C. U.1 652 583 524 475 426 377 348 309 2710 25

Blackhousingexteriorfor coolerballastoperatingtemperature

One piece-housing isembossed constructionfor added strength Fully gasketed

lens frame

Turned-upedges forsafe handling

Asymmetrical distributionSymmetrical distributionLens framejamb finishedblack for positivelight stop

Blackhousingexteriorfor coolerballastoperatingtemperature

One piece-housing isembossed constructionfor added strength Fully gasketed

lens frame

Turned-upedges forsafe handling

Asymmetrical distributionSymmetrical distributionLens framejamb finishedblack for positivelight stop

built-in hold-down clipbefore installation

hold-down clipinstalled (lay-in grid)

Page 136: LRG CFI

SUS2GFSMA632 120 O6

SUS2GFSMA432 120 O4

143

Medical Luminaires

Lamps Exposed Flanged forqty/type T-Grid dry or plaster6-T8 SUS2GFSMA632 SUS2FFSMA632

Ordering Guide

Basic catalogue number : Voltage : Ballast : Options :SUS 632 120 See page 142 See page 142Surgical Perimeter 277 Add appropriateStatic Luminaire 347 suffix to catalogue

number

The footcandle readings of a typical 8' x 12' pattern layout of 8, 6 lampunits, illustrates that the asymmetric distribution adds 35% more light tothe operating area (room size 12' x 16' x 9' ceiling).

Electronic Ballast

Input Watts (120V) 176WBallast Factor .88

G TYPE ONLY

Lamps Exposed Flanged forqty/type T-Grid dry or plaster4-T8 SUS2GFSMA432 SUS2FFSMA432

Ordering Guide

The footcandle readings of a typical 8' x 12' pattern layout of 8, 4 lampunits, illustrates that the asymmetric distribution adds 35% more light tothe operating area (room size 12' x 16' x 9' ceiling).

Electronic Ballast

Input Watts (120V) 112WBallast Factor .88

Basic catalogue number : Voltage : Ballast : Options :

G TYPE ONLY

Page 137: LRG CFI

3736

2000

1000

0

30°

60°24" (610 mm)

4-1/2"(114.3 mm)

144

Medical LuminairesMDS 2’x 2’Recessed Examination Light

Features•2 units provide 123 average footcandles on patient’s bed when

installed over each end of bed.•Utilizes 2-2 lamp ballasts.•Utilizes 4-40 watt TT5 type lamps with excellent colour rendition (82

CRI).•3-1/2" x 3-1/2" cell size.•Door jamb with integral positive light stop.•Spring-loaded latches.•Integral earthquake clips.•Prismatic pattern 12 overlay to reduce glare and act as safety shield

for broken glass.•Specular, semi-specular or white louver, 36 cells.

Options pages 150-156Ballast Specify voltage (120, 277 or 347) and add suffix, e.g. 120SB.Magnetic Electronic PowerSpec Dimming40W TT5: BX 40W TT5: SB 40W TT5: PB

50W TT5: BE (not avail. in 347V)55W TT5: BF

T12 not available.Fusing Internal fusing. Suffix: F.Radio Interference Filter 120, 277, 347 volt, 50 or 60 Hz. Suffix: R.Electrical/Wiring Options For special wiring, fusing, electronicdimming ballasts, consult factory.NOTE: For plaster or drywall ceiling: DRYWALL KIT, FK92X2.

MDS2G36PS4FT120SB (Data)MDS (2 x 2)

RCR C. U.1 612 563 514 465 426 387 358 319 2810 26

MEDICAL

Page 138: LRG CFI

MDS2G36PS4FT 120 SB

145

Initial Footcandles on Bed1 Luminaire 2 Luminaires

Medical Luminaires

Type Examination Lamp Cataloguelight shielding qty/type number

MDS 36 Cell 4-TT5 MDS2G36PS4FT4 lamp 2' x 2' Low IridescenceRecessed Specular LouverExamination with Prismatic OverlayLight 36 Cell 4-TT5 MDS2G36WS4FT

White Louverwith Prismatic Overlay

Ordering GuideReference Data

Efficiency 55.9%Spacing Ratio 1.3

Electronic Ballast

Input Watts (120V) 136.0WBallast Factor .88

Wall

Basic catalogue number : Voltage : Ballast : Options :MDS Specular Louver 120 See page 144 See page 144

277 Add appropriate347 suffix to catalogue

number

Page 139: LRG CFI

0°30°

60°

90°1000

500

500

1000

90°

300

600

180° 150°

120°

600

300

0

30°

60°

146

Medical LuminairesOBL SeriesOver-bed, Wall Mounted

Features• For nursing homes, hospitals and other health

care facilities.• Separate lamp compartments for controlled uplight and downlight.• Four-way pull switch, standard (120 volt only).• .125 thick DR acrylic linear prismatic refractor. (impact resistant).• Flat white fascia standard.• Cold rolled steel body with die-cast aluminum ends.• Concealed pull-action spring-loaded latches to

retain lens.• Optional oak fascia insert.

Features• For nursing homes, hospitals and other healthcare facilities.• Separate lamp compartments for controlled uplight and downlight.• Four-way pull switch optional (120 volt only).• Convenience outlet KO’s optional for left or right assembly.• 20 gauge steel body.• Acrylic pattern 12 refractors.• Semi-gloss, white acrylic baked enamel exterior finish standard.• Spotweld construction.

MEDICAL

OBL332120SO (Data)OBL Overbedlight

RCR C. U.1 612 563 514 465 426 387 358 319 2810 26

BED332120SO (Data)BED Bedlight

RCR C. U.1 612 563 514 465 426 387 358 319 2810 26

Options page 150-156Ballast Specify voltage (120 or 277) and type and add suffix (eg. 277SO).

Electronic <10THD POWER SPEC DIMMINGT8: SO T8: HI T8: PS

Optional Fascia Insert Oak—to order substitute K for L in CatalogNumber (i.e. OBL332 to OBK332).

Radio Interference Filter 120 or 277 volt, 50 or 60 Hz. One per fixturestandard. Suffix: R.

Nite Light Consult factory.

Medical LuminairesBED 3’, 4’Over-bed, Wall-mounted

5-9/16"" (141mm)Pull Switch

6-1/16""(154mm)

Request Folio R35-10 REV. A

Switching:4 Lamps = 1, 2, 3, 43 Lamps = 1, 2, 42 Lamps = 2, 4

K12PRISMATIC LENS

Options pages 150-156Ballast Specify voltage (120, 277 or 347) and add suffix, eg. 120SO.Magnetic ElectronicT8: OC T8: SOFor T12 see page 151.Radio Interference Filter 120, 277, 347 volt, 50 or 60 Hz. Suffix: R.Night Light† Incandescent, down section : NID ; up section NIU.

Fluorescent, down section : NPD ; up section NPU.Pull Switch† : 2 way switch Left side : S2L,

4 way switch Left side : S4L,Right side : S2R or S4R.

Convenience† Outlet : Left side COL, Right side COR.†Accessories, 120V only.

Page 140: LRG CFI

OBL332 120 SO R

147

Medical Luminaires

BED332 120 SO

3’(914.4 mm)

4’ (1219.2 mm)

3’ (914.4 mm)

2’ (609 mm)

1’ (304.6 mm)

0

1’ (304.6 mm)

2’ (609 mm)

3’ (914.4 mm)

4’ (1219.2 mm)

1’ (3

04.6

mm

)

2’ (6

09 m

m)

3’ (9

14.4

mm

)

4’ (1

219.

2 m

m)

Lamp Fixture LampConfiguration Length Qty/Type Catalog no.2 Up/1 Down 48" 3-T8 OBL3322 Up/2 Down 48" 4-T8 OBL4321 Up/1 Down 48" 2-T8 OBL232

Ordering Guide

Ordering GuideLamp Luminaire Lamp Catalogueconfiguration length qty/type number1 Up/1 Down 37-3/16" 2-T8 BED2252 Up/1 Down 37-3/16" 3-T8 BED3252 Up/2 Down 37-3/16" 4-T8 BED4251 Up/1 Down 49-3/16" 2-T8 BED2322 Up/1 Down 49-3/16" 3-T8 BED3322 Up/2 Down 49-3/16" 4-T8 BED432

Basic catalogue number : Voltage : Ballast : Options :

SIDE VIEW

Reading Position

Isolux Curve

45 FC reading plane(60° from horizontal

horizontal footcandles3’ 6” (1070 mm) from floorup and down lightdown light only

PLANE VIEW30 FC downlight only

3’ 6”(1070mm)

reading plane

Basic catalogue number : Voltage : Ballast : Options :Overbed mounted luminaire 120 See page 146 See page 146.

277 Add appropriatesuffixe to catalogueNumber.

6’(1828.8 mm)

3’(914.4 mm)

SIDE VIEW

Reading Position

50 FC reading plane(60° from horizontal

3’ 6”(1070mm)

reading plane

6’(1828.8 mm)

3’(914.4 mm)

Page 141: LRG CFI

148

Hea

t tra

nsfe

r (B

TUH

)

Return air flow (CFM)

Air Handling DataAir Return / Heat Transfer Data

All performance data on the 2’ x 2’luminaire is based on a maintainedroom temperature of 75°F (24°C). Airperformance tests were conducted inaccordance with Air Diffusion Council(ADC) air diffusing troffer heatremoval test code TC-66.

NEG

ATIV

E ST

ATIC

PRE

SSUR

E (IN

. OF

H 2O)

NEG

ATIV

E ST

ATIC

PRE

SSUR

E (IN

. OF

H 2O)

All performance data on the 2’ x 4’ luminaire is based on a maintainedroom temperature of 75°F (24°C). Air performance tests were conducted inaccordance with Air Diffusion Council (ADC) air diffusing troffer heatremoval test code TC-66.

Hea

t tra

nsfe

r (B

TUH

)

Return air flow (CFM)

1. Heat removal through lamp compartment, two endentry

2. Return air through two side slots, direct exhaust3. Combination heat removal / return air through lamp

compartment and two side slots

Heat transfer, energy distribution,two lamps

Return air flow (CFM)

1. Input, BTUH2. Heat removed; BTUH3. Heat to space; BTUH

Heat transfer, energy distribution,two lamps

Return air flow (CFM)

2’ x 4’ size Deepcel, Parabaffle, Vision Smart

2’ x 2’ size Deepcel, Parabaffle, Vision Smart

Heat transfer, energy distribution,three lamps — four lamps

Heat removal through lamp compartment

1. Input, BTUH2. Heat removed; BTUH3. Heat to space; BTUH

Page 142: LRG CFI

149

300200

100

50

10

300200

100

50

10

300200

100

50

10

300200

100

50

10

.001 .005 .010 .05 .10Negative Static Pressure (IN. of H2O)

.001 .005 .010 .05 .10Negative Static Pressure (IN. of H2O)

Retu

rn a

ir flo

w -

Cubi

c fe

et p

er m

inut

eRe

turn

air

flow

- Cu

bic

feet

per

min

ute

.001 .005 .010 .05 .10Negative Static Pressure (IN. of H2O)

Retu

rn a

ir flo

w -

Cubi

c fe

et p

er m

inut

e

.001 .005 .010 .05 .10Negative Static Pressure (IN. of H2O)

Retu

rn a

ir flo

w -

Cubi

c fe

et p

er m

inut

e

All performance data on the 1’ x 4’ luminaire is based on amaintained room temperature of 75°F (24°C). Air performance testswere conducted in accordance with Air Diffusion Council (ADC) airdiffusing troffer heat removal test code TC-66.

Return air flow (CFM)

Heat transfer, energy distribution,two F40 lamps

Return air flow (CFM)

Heat removal through lamp compartment

Slot grid or narrow grid

Technical DataDeepcel, Parabaffle, Paralyte

20 air changes per hour at only .01negative static pressure whenmounted in 8’ x 10’ layout.

Standard grid or two directionalconcealed grid

Standard grid or two directionalconcealed grid

Through the lamp compartmentonly.

Slot grid or narrow grid

Through the lamp compartment andside slots.20 air changes per hour at only .008

negative static pressure whenmounted in 8’ x 10’ layout.

For prismalyte plus lens air data please consult yourCFI Fluorescent representative.

1’ x 4’ size Deepcel, VP / VR

PARALYTE 2 X 4 See pages 36-37 PARALYTE 2 X 2 See pages 38-39

NEG

ATIV

E ST

ATIC

PRE

SSUR

E (IN

. OF

H 2O)

1. Input, BTUH2. Heat removed; BTUH3. Heat to space; BTUH

Hea

t tra

nsfe

r (B

TUH

)

Page 143: LRG CFI

DP A 2 G 18 L S 3 32 120 O3

SP S 2 G FS VA 4 32 120 O4

150

Numbering System LogicParabolic and Lens Troffer

Parabolic (Recessed and Surface)

Family

DP: DeepcelPL: ParalyteMP: ParabaffleVP: Vision Smart

PreferredVR: Vision Smart

RecommendedAD, DX, DK, DZ,DV, DN: Vision

Smart PreferredDD: Deepcel 20x60ST: Stacklyte

Body Style

A: Air SupplyS: StaticB: Surface Box

LuminaireWidth

1: 12”2: 24”5: 20”8: 8”

Ceiling Type

G: Grid(lay-in T bar)

T: Slot grid or two-directionalconcealedT (see options)

Number of cells

8: 1x8 (1’x4’)9: 3x3 (2’x2’)10: 1x10 (1’x4’)12: 2x6 (2’x4’-

20”x60”)3x4 (2’x2’)1x12 (1 x4’)

16: 4x4 (2’x2’)1x16 (8”x48”-12”x60”-12”x48”)2x8 (1’x4’-20”x60”-20”x48”)

18: 3x6 (2’x4’-20”x48”-20”x60”)24: 2x12 (1’x4’)

3x8 (2’x4’)27: 3x9 (2’x4’)29: 2x9 (2’x4’-20”x48”-20”x60”)32: 2x16 (1’x4’-20”x60”)

4x8 (2’x4’)36: 6x6 (2’x2’)78: 6x13 (2’x4’)

Ballast coverlouver mountingmethod

S: StandardP: PremiumR: Specular

reflectorL: Lay-in louver

LampQuantity in aluminairecross-section

1234

Lamp Type

17: T8 2’20: T12 2’32: T8 4’34: T12 4’2U:T8U1.66U:T8U6 or T12U6FT: TT528: T5 linear54: T5 linear14: T5 linear24: T5 linear

Options

Addappropriatesuffix tocataloguenumber

Voltage

120277347UNV (120V/277V)

Please note that this ordering guide lists all Parabolic Luminaire numbering logic. The possible combinations and options do not apply toall luminaires. Please refer to the specific luminaire page.

Lens (Recessed and Surface) Except AA Troffer.

Family

SP: SpecPlusPR: Prismalyte

PlusAAS: High Efficiency

White PaintEL: SilverescentDS: 20” x 60”SQ: SpecTrofferDL: 500mm x 1200mmDM: 500mm x 1500mmDT: 20” x 48”SU: Operating Room Luminaire

Luminaire Width

1: 12”2: 24”5: 20”

Ceiling Type

G: Grid(lay-in T bar)

L: Self-Flange(T-Bar)

Lens Frame

FS: Flat steel frame

RA: Regressedaluminumframe

FA: Flataluminumframe

LI: Lay in lensRF: Regressed

aluminum floating door

Lens / shieldingtype

VA (virgin acrylic)standard (seeoptions andconsult factorypage 155)

LampQuantity in aluminairecross-section

12346

Lamp Type

17: T8 2’20: T12 2’32: T8 4’34: T12 4’2U: T8U1.66U: T8U6 or T12U6FT: TT5

Options

Add appropriatesuffix tocataloguenumber

Voltage

120277347

Ballast Type

See page 151.

Numbering system logic for AA Troffer see page 54.

Please note that this ordering guide lists all Lens luminaire numbering logic. The possible combinations and options do not apply toall luminaires. Please refer to the specific luminaire page.

Louverfinish

L: LowiridescenceSemi-specular

P: LowiridescenceSpecular

M: Matte lowiridescence

Body Style

A: Air SupplyS: StaticB: Surface Box

Ballast Type

See page 151.

Page 144: LRG CFI

2 32 120 SO

2 48 120 SO

151

General Lamp and Ballast Logic

Lamp and ballast logic for all luminaires

Except AA, Wal-Lyter, Walmaster, Ceiling-Lyter, Bi-Lyter, Impressions, TH, TT, TN, TX, CSW, Belmont Family, Lumiplex, SB, EE, FF, TU, VT, VTS,MD*4 and MD*Coffer.

Lamp Quantityin a luminairecross-section

12346

Lamp Type

15: T12 18”17: T8 2’20: T12 2’25: T8 3’30: T12 3’32: T8 4’34: T12 4’48: 4’ SL, HO96: 8’ SL, HO2U: T8U1.66U: T8U6 or T12U6FT: TT5 linear28: TT5 linear54: TT5 linear14: TT5 linear24: TT5 linear

Options

Add appropriatesuffix to catalogue number

Voltage

120277347UNV (120V/277V)

Ballast Type

Ballast suffix applied to all luminaires

TT5BA: 18W Electronic TT5 RSBB: 24W Electronic TT5 RSBE: 50W Electronic TT5 RSBF: 55W Electronic TT5 RSBR: 40W Electronic TT5 RSBX: 40W Magnetic TT5 RSB3: 3 LPB Electronic TT5 RSIB: 40W Electronic TT5 ISI3: 3 LPB 40W Electronic TT5 ISMX: Electronic Mark X 40W TT5*M7: Electronic Dimming Mark VII 40W TT5*PA: 18W TT5 PowerSpec Dimming*PB: 40W TT5 PowerSpec Dimming*PC: 50/55W TT5 PowerSpec Dimming*SB: 40W Generic Electronic TT5X3: 3 LPB 40W Electronic TT5 IS

*Not available in 347 volt.

T12SS: T12 Electronic

Lamp and ballast logic for :

For AA, TH, TT, TN, TX, CSW, SB, EE, FF, TU,VT and VTS.

Lamp Quantityin a luminairecross-section

1234

Lamp Type

18: 18” lamp24: 24” lamp36: 36” lamp48: 48” lamp

W8: 48” lamp wide body96: 96” lamp

XXT: XX” lamp(s) in tandem configurationU6: T8U6U2: T12U6U4: TT5

XXH: XX” lamp, High OutputXXS: XX” lamp, Slimline

XXHPF: XX” lamp, High Power Factor.

Options

Add appropriatesuffix to catalogue number

Ballast Type

LPB: Number of lamps per ballastIS: Instant startRS: Rapid startPG: Program start

T8LW: Electronic Low Watt ISME: Electronic Helios dimming T8*MX: Electronic Mark X dimming T8*M7: Electronic Mark VII dimming T8*OC: Magnetic T8O3: 3 LPB T8 Electronic IS, <20% THDO4: 4 LPB T8 Electronic IS, <20% THDO6: 2 ballasts O3, <20% THDPS: PowerSpec Dimming T8*RO: 1 or 2 LPB T8 Electronic RS, <10% THDR3: 3 LPB T8 Electronic RS, <10% THDR4: 4 LPB T8 Electronic RS, <10% THDR6: 2 ballasts R3SC: Electronic Cold Start (0°F) ISSO: 1 or 2 LPB T8 Electronic ISR3: 3 LPB T8 Electronic RS, <20% THDR4: 4 LPB T8 Electronic RS, <20% THDSR: 1 or 2 LPB T8 Electronic RS, <20% THD

*Not available in 347 volt.

T5 LinearPI: T5 Electronic ISPG: T5 Electronic PG

Voltage

120277347

Page 145: LRG CFI

152

6"

1-5/8"

Technical Lamp informationRecessed Luminaire Options

Lamp Lamp Model # Rated Initial Colour Temperature CRI Nominal Lamp Electronic BallastWattage Manu- (add colour temperature Life Lumens (varies by lamp Length (volts) Availability

facturer desired in space ____) (hours) at 25°C manufacturer) °K inches (mm) *consult your representative onnew ballast voltage availability

QTQuad 4 pin GE F18DBX/SPX ____/4P 10000 1250 3000, 3500, 4000 82 5.8” (147mm) 120, 277, 347

18 PHILIPS PL-C 18W/841/4P/ALTO 12000 1250 3000, 3500, 4100 82 5 11/16” (144.5mm) 120, 277, 347OSRAM Sylvania CF18DD/E/8_____ 10000 1250 3000, 3500, 4100 82 5.8” (147mm) 120, 277, 347

TTTTriple Tube 4 pin GE F32TBX/SPX ____/A/4P 10000 2400 3000, 3500, 4000 82 5.8” (147mm) 120, 277, 347

32 PHILIPS PL-T 32W/841/4P/ALTO 12000 2400 3000, 3500, 4100 82 5 5/8” (143mm) 120, 277, 347OSRAM Sylvania CF32DT/E/IN/8_____ 10000 2400 3000, 3500, 4100 82 5.6” (142mm) 120, 277, 347

42 GE F42TBX/SPX ___/A/4P 10000 3200 3000, 3500, 4100 82 6.4” (163mm) 120, 277, 347PHILIPS PL-T 42W/841/4P/ALTO 12000 3200 3000, 3500, 4100 82 6 3/8” (162mm) 120, 277, 347

OSRAM Sylvania CF42DT/E/IN/8____ 10000 3200 3000, 3500, 4100 82 6.4” (163mm) 120, 277, 347TT5

Preheat GE F18BX/SPX ____ 10000 1200 3000, 3500, 4100 82 9” (229mm) 120, 277, 34718 PHILIPS PL-L 18W/841/4P ____ 15000 1250 3000, 3500, 4100 82 8 15/16” (227mm) 120, 277, 347

OSRAM Sylvania FT18DL/8_____ 20000 1250 3000, 3500, 4100 82 10.5” (267mm) 120, 277, 347Rapid GE F18BXSPX ____/RS 20000 1250 3000, 3500, 4100 82 10.5” (267mm) 120, 277, 347Start PHILIPS PL-L18/ ____ 15000 1250 3000, 3500, 4100 82 8 15/16” (227mm) 120, 277, 347

18 OSRAM Sylvania FT18DL/8____/RS 20000 1250 3000, 3500, 4100 82 10.5” (267mm) 120, 277, 347Preheat GE F27/24BX/SPX ___ 12000 1800 3000, 3500, 4100 82 12.9” (326mm) 120, 277, 347

24 PHILIPS PL-L 24W/841/4P ____ 15000 1800 3000, 3500, 4100 82 12 11/16” (322mm) 120, 277, 347OSRAM Sylvania FT24DL/8____ 12000 1800 3000, 3500, 4100 82 12.9” (329mm) 120, 277, 347

Rapid GE F40/30BX/SPX ___ 20000 3150 3000, 3500, 4100 82 22.5” (572mm) 120, 277, 347Start PHILIPS PL-L 40W/841/4P/RS/IS ____ 20000 3300 3000, 3500, 4100 82 22 1/2” (572mm) 120, 277, 347

40 OSRAM Sylvania FT40DL/____/RS 20000 3150 3000, 3500, 4100 82 22.6” (573mm) 120, 277, 347Rapid GE F50BX/SPX____/RS 14000 4300 3000, 3500, 4100 82 22.5” (572mm) 120, 277, 347Start PHILIPS PL-L 50W/841/4P/RS 20000 4300 3000, 3500, 4100 82 22 1/2” (572mm) 120, 277, 347

50 OSRAM Sylvania N / APreheat GE N / A

55 PHILIPS N / AOSRAM Sylvania FT55DL/8____ 12000 4800 3000, 3500, 4100 82 21.1”(535mm) 120, 277

T8U6

32 OSRAM Sylvania F32T8/SPX____/U/6 20000 2800 3000, 3500, 4100 86 22.5” (572mm) 120, 277,347PHILIPS FB32T8/TL850/6 ALTO 20000 2750 5000 84 22 7/16” (570mm) 120, 277,347

GE FB032/8____/6 20000 2850 3000, 3500, 4100 82 22.5” (572mm) 120, 277,347

T8U1.631 OSRAM Sylvania F31T8/SPX____/U 20000 2725 3000, 3500, 4100 82 22.5” (572mm) 120, 277,347

PHILIPS N / AGE FB031/8____ 20000 2725 3000, 3500, 4100 82 22.5” (572mm) 120, 277,347

LINEAR T817 OSRAM Sylvania F17T8/SPX____ 20000 1350 3000, 3500, 4100 86 24” 120, 277,347

PHILIPS F17T8/TL841/ALTO 20000 1400 3000, 3500, 4100 86 24” (610mm) 120, 277,347GE FO17/8____ 20000 1400 3000, 3500, 4100 84 24” (610mm) 120, 277,347

25 OSRAM Sylvania F25T8/SPX____ 20000 2150 3000, 3500, 4100 86 36” 120, 277,347PHILIPS F25T8/TL841/ALTO 20000 2225 3000, 3500, 4100 86 36” (914mm) 120, 277,347

GE FO25/8____ 20000 2150 3000, 3500, 4100 82 36” (914mm) 120, 277,34732 OSRAM Sylvania F32T8/SPX____ 20000 2950 3000, 3500, 4100 86 48” 120, 277,347

PHILIPS F32T8/TL841/ALTO____ 20000 2950 3000, 3500, 4100 86 48” (1220mm) 120, 277,347GE FO32/8____ 20000 3000 3000, 3500, 4100 85 48” (1220mm) 120, 277,347

LINEAR T514 OSRAM Sylvania FP14W/T5/8____ 20000 1350 3000, 3500, 4100 85 21.6” 120, 277, 347

Stand. T5 PHILIPS F14T5/841____ 20000 1350 3000, 3500, 4100 85 22” (559mm) 120, 277,347GE FP14/8____ 20000 1220 3000, 3500, 4100 82 22.2” (563mm) 120, 277,347

24 OSRAM Sylvania F24W/T5/8____ 20000 2000 3000, 3500, 4100 85 33.4” 120, 277, 347High PHILIPS F24T5/841/HO____ 20000 2000 3000, 3500, 4100 85 22” (559mm) 120, 277,347

Output T5 GE FP24/HO/8/____ 20000 1760 3000, 3500, 4100 82 22.2” (563mm) 120, 277,34728 OSRAM Sylvania F28W/T5/8____ 20000 2900 3000, 3500, 4100 85 45.2” 120, 277, 347

Stand. T5 PHILIPS F28T5/841____ 20000 2900 3000, 3500, 4100 85 46” (1163mm) 120, 277,347GE FP28/8____ 20000 2610 3000, 3500, 4100 82 46” (1163mm) 120, 277,347

54 OSRAM Sylvania F54W/T5/8____ 20000 5000 3000, 3500, 4100 85 45.2” 120, 277, 347High PHILIPS F54T5/841/HO/ALTO 25000 5000 3000, 3500, 4100 85 46” (1163mm) 120, 277,347

Output T5 GE FP54/HO/8/____ 20000 4400 3000, 3500, 4100 82 46” (1163mm) 120, 277,347

LAMP CHART IS TO BE USED AS A GUIDE ONLY. CHECK LAMP/BALLAST MANUFACTURER DATA FOR EXACT SPECIFICATIONS.

Page 146: LRG CFI

153

A B

49"(1245mm)

26"(635mm)

3/16" (5mm)

1-3/8"(35mm)

1-1/2"(38mm)

49"(1245mm)

25"(635mm)

15/16" (24mm)

10-1/4"(8"x48")

or13-1/8"(1'x4')

Features• Designed to permit use of grid (NEMA G) luminaires in ceilings

requiring flanges.• May be used with any G type (suspended grid ceiling with lay-in T-bar)

or AA Series CFI Fluorescent troffer.• Extruded aluminum construction with mitered corners.• Includes screws for complete assembly.

Mounting Methods for “F” Mounting Frame Assembly. Note: Do not use wire hangers (by others) at end of luminaire.

Wire Hanger(by others)Luminaire Luminaire

Wire Hanger(by others)

“F” Mounting Frame

Plaster Frame

Plaster(by others)

Luminaire

Wire Hanger(by others)

“F” Mounting Frame

Channel (by others)

Accoustical Tile(by others)

Drywall Kit

Catalogue Luminaire Single Luminaire Row InstallationNumber Size Ceiling Opening Ceiling Opening

A B C DFK908X4 8’’ x 48’’ 9-3/4” (248mm) 48-5/8” (1235mm) X XFK920X4 20’’ x 48’’ 20-5/8 (524mm) 48-5/8” (1235mm) X XFK91X4 1’ x 4’ 12-5/8” (321mm) 48-5/8” (1235mm)FK91X4CRM 1’ x 4’ X X

12-5/8” (321mm) D†

FK92X4 2’ x 4’ 24-5/8” (626mm) 48-5/8” (1235mm)FK92X4CRM 2’ x 4’ X X

24-5/8” (626mm) D†

FK92X2 2’ x 2’ 24-5/8” (626mm) 24-5/8” (626mm) X X

D† = 48-5/8’’ + [ (# of fixture - 1) x 48-3/16] OR D= 1235mm + [ (# of fixture - 1) x 1224mm]Example: Row of 3 luminaires: D = 48-5/8’’ + [(3-1) x 48-3/16] = 145” or 3683 mm

“F” Mounting Frame Assembly Installation Instructions

- Includes screws for complete assembly- May be used for continuous row mounting using FK CRM

(see ordering information matrix).- Not suitable for Paralyte Series (2 x 2, 2 x 4) and ADS8

1/8” Dia Screw Assembly Hole

“F” Mounting Frame Assembly 8" x 48", 20” x 48”, 1' x 4', 2' x 2', 2' x 4'For Mounting in Drywall or Ceilings Requiring Flanges

1/4” Dia. Wire Hanger Hole

- Includes screws for complete assembly- May be used for continuous row mounting using FK CRM

(see ordering information matrix).- Not suitable for Paralyte Series (2 x 2, 2 x 4) and ADS8

RegularMounting Frame

Mounting Framefor continuous

row mounting (FKCRM)

A) Single Luminaire Installation

B) Row Installation

“F” Mounting Frame

Accoustical Tile(by others)

Page 147: LRG CFI

154

Cat. Number LuminaireEE9G4 EE/FF SeriesTU9G4 TU SeriesSB8G1-24 SB124SB8G1-36 SB136SB8G1-48 SB148, SB148TSB8G2-36 SB236SB8G2-48 SB148H, SB148HT

SB248, SB248TSB8G4-48 SB348, SB448SV5GxG2 SV2SSV5GxG3 SV3SSV5GxG4 SV4S

Industrial Luminaire Options

Stem and Canopy Sets

Suspends luminaire 12”, 18”, 24”, 36”,48” from surface and can be used inconjunction with Heavy Duty Slide GripHanger.Catalogue Number:STKF12 (12”), STKF18 (18”), STKF24(24”), STKF36 (36”), STKF48 (48”).

Heavy Duty Slide-Grip Hanger

Order Catalogue Number: EE9H3For luminaires: EE248H

EE248HTSB248HSB248HTTU248HTU248HT

Reflector Row Aligners

Tough, plastic aligners for luminairereflectors. Catalogue Number: TU9RA - TU Series (shown)EE9RA - EE / FF Series

Twist Tee Hanger

For installation of 4-1/2" wide (channel)luminaire on exposed “T” grid ceilings orhard surfaces. Provides 1-1/2" clearancefrom surface. Catalogue Number: EE9H1For luminaires: SB248

SB248TEE248EE248TSB296S

Fusing

Suffix F Internal fusing.

Radio Interference Filter

Suffix R Inductive capacitor circuitdesigned to minimize interference fromline radiation or feedback. 120, 277 or347, 50 or 60 Hz. Example: TU248120SOR

Wire Guards

Hinge and latch positive-lockconstruction, complete withlongitudinal and transversestruts for secure protection.

Chain Hanger Kit

Two 24” heavy duty link chains with sturdy “V” hooks that grip luminaires atfour knockout points for level suspension.Catalogue Number:EE9HC (for SB, SV, EE, FF luminaires)

Canopy Spacer (1-1/2")

Suspends luminaire approximately 1-1/2"from surface.Catalogue Number: STSK

Quick Connect Plug-In forContinuous WirewaySuffix CL3 - Single switching

CL4 - Double switching

Page 148: LRG CFI

155

Technical Information (industrial applications)

Flat Lens and Louver Options

COMPARISON BALLAST / LAMP DATA FOR INDUSTRIAL APPLICATIONS (8’)# of Lamp Ballast type + System Lamp Lamp Lumens/ Ballast

lamps Type quantity wattage life lumens watt suffix

2 T12 Slimline 8’ Magnetic instant start - 1 ballast 158 12,000 6100 67 LE

2 T12 Slimline 8’ Electronic instant start - 1 ballast 132 12,000 6100 92 SS

2 T12 H.O. 8’ Magnetic rapid start energy saving - 1 ballast 237 12,000 8800 74 LE

2 T8 - 8’ Electronic instant start - 1 ballast 110 15,000 6000 109 SO

4 T8 - 4’ Tandem Magnetic rapid start - 2 ballasts 142 20,000 3050 86 OC

4 T8 - 4’ Tandem Electronic instant start - 1 ballast 112 20,000 3050 109 O4

4 T8 - 4’ Tandem Hybrid rapid start (Powerkut) - 2 ballasts 124 20,000 3050 98 OP

2 T8 - 8’ Electronic high output ballast - 1 ballast 174 15,000 6000 69 **

4 T8 - 4’ Tandem 1.28 ballast factor, ballast driving lamps 172 20,000 3050 70 **at full rated wattage - 1 ballast

2 T8 H.O. - 8’ Electronic ballast - 1 ballast 155 18,000 8200 91 SO

Figures are rated values not designed values.**Consult factory (actual lumens / watt are higher).

FusingSuffix : F Internal fusing.

Radio Interference FilterR Inductive capacitor circuit designed tominimize interference from line radiationor feedback.120V, 277V or 347V 50 or 60 Hz.One per luminaire standard.Example: DPA2G18LS33212003R

Lightolier PowerSpecDimming BallastFor 40W TT5 (PB) or T8 (PS).See Catalogue Numbering Systempage 115.Example: DPS2G12LP232120PS

PrewiringFF6; FF14 3/8" factory prewired cablewired into luminaire. Configurationsavailable in various wire gauges, num-bers of wires and lengths up to 6'.Example: DPA2G18LS332120O3FF6

(3 #14 AWG leads, 6' long)DPA2G18LS332120O3FF14(4 #14 AWG leads, 6' long)

Energy Saving TandemFactory prewired interconnection cablefor plug-together installation of pairs oftroffers. Designed to save energy by theelimination of 1 ballast. Consult factory.

Flex Wiring SystemsAll CFI Fluorescent troffers can be usedwith standard wiring systems available.Consult factory.

Radio Frequency ShieldingFor hospitals, TV stations or whereversensitive electronic equipment is in use.Consult factory.

Fluorescent EmergencyLighting SystemO Factory-installed emergency powerbattery pack with charger and inverter,B100 or equal, 120V, 277V or 347V(1 lamp, 90 min. at 15%)Example: SPS2GFSVA332120O3OConsult CFI Representative for specificproducts availability.

Recessed Luminaire Options

VA Pattern 12 lens .095” nominal - Prismatic lensVB Pattern 12 lens .125” nominal - Prismatic lensVY Pattern 12 lens .130” ( .125” minimum)VK Pattern 12 lens .140” acrituffVX Pattern 12 lens .125” polycarbonatePY Pattern 12 lens .187” polycarbonateKA Pattern 19 lens .156” nominal - Prismatic lensKS Pattern 19 lens .156” nominal silver tintQA Pattern 20 lens .140” nominalKK Pattern 23 lens .100”PA Opal lens .080” nominal

Recessed and Surface Troffer / Flat lens and Louver optionsFor other available lenses and louvers, consult your CFI Fluorescent Representative.

PE Opal lens .187” nominalPD Opal lens .125” nominalPR Pattern 49 lens .160” nominal with radio frequency interference filter lensEE KSH 3-E lensCG Pattern 73 tempered glass .150” (for RVS)AH Holophane 6150 molded 1 x 4 / 6250 molded 2 x 4HR Holophane 8224 lensHY Holophane 8224 lens with frost overlay sealedDA Dropped Opal lensAA 1/2 x 1/2 x 1/2 white eggcrate acrylicAO 1/2 x 1/2 x 1/2 parabolic gold acrylic

AP 1/2 x 1/2 x 1/2 parabolic silver acrylicBO 1/2 x 1/2 x 1/2 parabolic gold styreneBP 1/2 x 1/2 x 1/2 parabolic silver styreneGK 3/4 x 3/4 x 1/2 parabolic gold acrylicSE 3/4 x 3/4 x 1/2 parabolic silver styreneSF 3/4 x 3/4 x 1/2 parabolic silver acrylicSG 3/4 x 3/4 x 1/2 parabolic gold styreneUC 3/4 x 3/4 x 3/4 parabolic aluminumSA 1 1/2 x 1 1/2 x 7/8 parabolic silver acrylicXY 2 x 2 x 1 3/8 parabolic aluminum (20”x 60” and 20” x 48”only)

Page 149: LRG CFI

156

Dimming Information

Compatible Dimmers

Dimming ballast selection and dimmers (see ballast suffix page ?? to order.)

MultiSet MS600HDF120 MS600EB N / A N / AMH600HDF120 MH600EBMH1500HDF120 MH1000EBall VA models* MH1500EB

MultiSet Pro MSP600HDF120 MSP600EB N / A N / AMHP600HDF120 MHP600EBMHP1500HDF120 MHP1000EBall VA models*

Sunrise Preset ZP600HDF120 ZP600EB ZP600FAM120 ZP600FAM120all VA models* ZP1000EB

Momentum MP1500HDF120 MP1500EB MP1500FAM120 MP1500FAM120Preset all VA models*Onset OS600HDF120 OS600EB N / A N / A

OH600HDF120 OS1000EBOH1500HDF120 OH1500EBall VA models*

Rockslide all VA models* N / A N / A N / APreset

Precision all VA models* N / A N / A N / ARotaryInsight all VA models* N / A N / A N / A

OccupancySensor

Lytemode LM2-2400HDF N / A LM2-2400FAM LM2-2400FAMLM2-2400HDF-32 LM2-2400FAM-32 LM2-2400FAM-32

LM2-4000HDF LM2-4000FAM LM2-4000FAMLMDP-20HDF-120LMDP-20HDF-277

Ballast Lightolier Advance Advance OSRAMSelection PowerSpec HDF Mark X Mark VII QuicktronicLinear T8 100 - 1 % 100 - 5 % 100 - 5 % 110 - 5 %

120 / 277 volts 120 / 277 volts 120 / 277 volts 120 / 277 voltsTT5 100 - 10 % 100 - 5 % 100 - 5 % N / A

120 / 277 volts 120 / 277 volts 120 / 277 voltsWiring 3 - Wire 2 - Wire 2 - Wire line voltage 2 - Wire line voltage

line voltage line voltage + 2 low voltage wires + 2 low voltage wires(0 - 10V) separate conduit (0 - 10V) separate conduit

Lamp Mfr. Osram / Sylvania Osram / Sylvania Osram / Sylvania Osram / SylvaniaPhilips Philips Philips Philips

GE GE GE GE

* Use with DA10HDF, DA20HDF120l or DAHDF277l interfaces.** Use with DA110ESI or DA210ESI interfaces.

PowerSpec ballast technical informationT8 PowerSpec HDF BallastHDF132T8UNV HDF232T8UNV

Lamp 1x25W 1x25W 1x32W 1x32W 2x25W 2x25W 2x32W 2x32WVoltage 120V 277V 120V 277V 120V 277V 120V 277VDimming range 100-1% 100-1% 100-1% 100-1% 100-1% 100-1% 100-1% 100-1%Input Wattage (max.) 28 29 36 37 54 54 68 68Line Current (amps) 2,3 0,1 0,3 1,3 0,46 0,2 0,57 0,25Input Wattage (min) 9 10 9 10 12 13 13 15Ballast Factor (full) >87% >87% >87% >87% >87% >87% >87% >87%Lamp CCF <1.6 <1.6 <1.6 <1.6 <1.6 <1.6 <1.6 <1.6Power Factor (full) >98% >98% >98% >98% >98% >98% >98% >98%Power Factor (low) >97% >97% >97% >97% >97% >97% >97% >97%T.H.D. (@ 100% Lx) <10% <10% <10% <10% <10% <10% <10% <10%T.H.D. (@ 1% Lx) <10% <20% <10% <20% <10% <20% <10% <20%Min. Starting Temp. F 50 50 50 50 50 50 50 50

TT5 PowerSpec HDF BallastHDF118T5120I HDF118T5277I HDF140T5120I HDF140T5277I HDF155120I HDF155277I HDF218T5120I HDF218277I HDF240T5120I HDF240T5277I

Lamp 1x18W 1x18W 1x40W 1x40W 1X55W 1X55W 2x18W 2x18W 2X40W 2X40WVoltage 120V 277V 120V 277V 120V 277V 120V 277V 120V 277VDimming range 100-10% 100-10% 100-10% 100-10% 100-10% 100-10% 100-10% 100-10% 100-10% 100-10%Input Wattage (max.) 22 22 41 41 56 56 39 39 75 75Line Current (amps) 0,18 0,08 0,33 0,15 0,45 0,2 0,32 0,14 0,61 0,27Input Wattage (min) 15 15 20 20 20 20 20 20 25 25Ballast Factor (full) >90% >90% >90% >90% >90% >90% >90% >90% >90% >90%Lamp CCF <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7 <1.7Power Factor (full) >95% >95% >95% >95% >95% >95% >95% >95% >95% >95%Power Factor (low) >80% >80% >80% >80% >80% >80% >80% >80% >80% >80%T.H.D. (@ 100% Lx) <13% <13% <13% <13% <13% <13% <13% <13% <13% <13%T.H.D. (@ 1% Lx) <20% <20% <20% <20% <20% <20% <20% <20% <20% <20%Min. Starting Temp. F 50 50 50 50 50 50 50 50 50 50

Page 150: LRG CFI

The Canlyte - Cornwall Location is Canada’s largest and most modern fluorescent lighting facility