lot 7 burleigh view (a) unit 2 - custom land group
TRANSCRIPT
CLIENT:
GENERAL NOTES
DO NOT SCALE PLANS, USE WRITTEN DIMENSIONS ONLY.
THE OWNER/BUILDER SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS, LEVELS, SETBACKS
AND SPECIFICATIONS PRIOR TO COMMENCING WORKS OR ORDERING MATERIALS AND SHALL BE
RESPONSIBLE FOR ENSURING THAT ALL BUILDING WORKS CONFORM TO THE BUILDING CODE OF
AUSTRALIA 2006, CURRENT AUSTRALIAN STANDARDS, BUILDING REGULATIONS AND TOWN
PLANNING REQUIREMENTS, REPORT ANY DISCREPANCIES TO BLUEWATER BUILDING DESIGNS.
ALL WORKS SHALL COMPLY WITH BUT NOT LIMITED TO THE BUILDING CODE OF AUSTRALIAN AND
THE AUSTRALIAN STANDARDS.
AS 1288 - 2006 GLASS IN BUILDINGS - SELECTION AND INSTALLATION
AS 1562 - 1992 DESIGN AND INSTALLATION OF SHEET ROOF AND WALL CLADDING
AS 1684 - 2010 NATIONAL TIMBER FRAMING CODE
AS 2049 - 2002 ROOF TILES
AS 2050 - 2002 INSTALLATION OF ROOF TILES
AS 2870 - 1996 RESIDENTIAL SLAB AND FOOTINGS - CONSTRUCTION
AS/NZS 2904 - 1995 DAMP-PROOF COURSES AND FLASHINGS
AS 3600 - 2000 CONCRETE STRUCTURES
AS 3660 - 2000 BARRIERS FOR SUBTERRANEAN TERMITES
AS 3700 - 2001 MASONRY IN BUILDINGS
AS 3740 - 2004 WATERPROOFING OF WET AREAS IN RESIDENTIAL BUILDINGS
AS 3786 - 1993 SMOKE ALARMS
AS 4055 - 2006 WIND LOADINGS FOR HOUSING
AS 4100 - 1998 STEEL STRUCTURES
THESE PLANS SHALL BE READ IN CONJUNCTION WITH ANY STRUCTURAL AND CIVIL ENGINEERING
COMPUTIONS AND DRAWINGS.
SOIL CLASSIFICATION - REFER TO STRUCTURAL ENGINEERS SOIL TEST.
ALL BUILDINGS SHALL BE PROTECTED AGAINST TERMITE ATTACK IN ACCORDANCE WITH AS
3660.1 AND A DURABLE NOTICE SHALL BE PLACED IN THE METER BOX INDICATING TYPE OF
BARRIER AND REQUIRED PERIODICAL INSPECTIONS.
SAFETY GLAZING TO BE USED IN THE FOLLOWINGS CASES -
i) ALL ROOMS - WITHIN 500mm VERTICAL OF THE FLOOR
ii) BATHROOMS - WITHIN 1500mm VERTICAL OF THE BATH BASE
iii) FULLY GLAZED DOORS
iv) SHOWER SCREENS
v) WITHIN 300mm OF A DOOR AND <1200mm ABOVE FLOOR LEVEL
vi) WINDOW SIZES ARE NOMINAL ONLY, ACTUAL SIZES WILL VARY
WITH MANUFACTURER, FLASHING ALL ROUND.
ALL GUTTERS TO BE QUAD GUTTERING WITH MIN. 100x75 RECTANGULAR OR 100 dia. DOWNPIPES,
EACH DOWNPIPE SHALL SERVICE A MAXIMUM ROOF AREA OF 36sq.m OR SHALL BE POSITIONED
AS PER AS 3500.3, 2003, SECTION 3. STORMWATER TO BE TAKEN TO THE LEGAL POINT OF
DISCHARGE AS DETERMINED BY THE RELEVANT AUTHORITY.
TILED DECKS OVER LIVABLE AREAS ARE TO BE IN THE FOLLOWING ORDER OVER THE FLOOR
JOISTS : 19mm COMPRESSED FIBRE CEMENT SHEET, WITH ONE LAYER OF PARCHEM EMERPROOF
750 WITH A SECOND LAYER OF SAND SEED WITH A DFT OF 1300 MICRON, INSTALLED TO MANUF.
SPECIFICATIONS, AND FLOOR TILES OVER, ALL CORNERS TO HAVE 20mm MASTIC SEALANT
UNDER THE PARCHEM EMERPROOF 750.
FOOTINGS NOT TO ENCROACH TITLE BOUNDARIES OR EASEMENTS. IT IS RECOMMENDED THAT
WHERE BUILDINGS ARE TO BE LOCATED IN CLOSE PROXIMITY OF BUNDARIES, A CHECK SURVEY
BE CONDUCTED BY A LICENSED SURVEYOR.
ALL STEELWORK IN MASONRY TO BE HOT DIP GALVANISED.
ALL WET AREAS TO COMPLY WITH BCA 3.8.1.2 AND AS 3740. SPLASH BACKS SHALL BE
IMPERVIOUS FOR 150mm ABOVE SINKS, TROUGHS AND HAND BASINS WITHIN 75mm OF THE
WALL.
PROVIDE WALL TIES AT 600mm SPACINGS BOTH VERTICAL AND HORIZONTAL AND WITHIN 300mm
OF ARTICULATION JOINTS. BRICK TIES TO BE STAINLESS STEEL.
SUB-FLOOR VENTILATION MINIMUM 7500mm sq FOR EXTERNAL WALLS AND 1500mm sq FOR
INTERNAL WALLS BELOW BEARER. THERMAL INSULATION; R2.5 BATTS TO CEILING AND R1.5
BATTS AND REFLECTIVE FOIL TO EXTERNAL WALLS OR AS PER ENERGY RATING.
STAIR REQUIREMENTS: MIN. TREAD 240mm, MIN. RISER 115mm, MAX. RISER 190mm, SPACE
BETWEEN OPEN TREADS MAX. 125mm. TREADS TO BE NON SLIP SURFACE. BALUSTRADES : MIN.
1000mm ABOVE LANDINGS WITH MAX. OPENING OF 125mm AND IN ACCORDANCE WITH BCA 3.9.2.
FOR STAINLESS STEEL BALUSTRADE, REFER TO Table 3.9.2.1 (WIRE BALUSTRADE
CONSTRUCTION - REQUIRED WIRE TENSION AMD MAXIMUM PERMISSIBLE DEFLECTION) OF THE
BCA.
THE BUILDER SHALL TAKE ALL STEPS NECESSARY TO ENSURE THE STABILITY OF EXISTING AND
NEW STRUCTURES THROUGH-OUT CONSTRUCTION.
SITE DETAILS:
JOB No: ISSUE:
BLUEWATER BUILDING DESIGNSBLUEWATER BUILDING DESIGNSBLUEWATER BUILDING DESIGNSBLUEWATER BUILDING DESIGNS
AREA
PROPERTY DETAILS
S.P. NUMBER
PARISH
COUNTY
LOT
PHONE: 0410 648 059ABN: 25 367 288 616
QBSA LIC. 1212800
EMAIL: [email protected]
Bluewater Template | Version 20.1.2
LOT 7 SIREC WAY BURLEIGH HEADS
A
Sheet List
Sheet NameSheetNumber
Site Plan 100
Floor Plan - UNIT 2 300
Elevations - UNIT 2 301
Electrical Plan 400
Internal Elevations 500
Internal Elevations 501
UNIT 2
UNIT 2
Natter Pty Ltd t/as Stroud Homes Gold CoastQBCC Licence: 108 1372 Phone: 07 5607 48501638 Gold Coast Highway, Burleigh Heads
PHONE: 0410 648 059ABN: 25 367 288 616
EMAIL: [email protected]
CLIENT:
SITE
DETAILS:
PROJECT:
JOB No:
ISSUE:DWG No:
SCALE:
DATE:
DRAWN:
A
ISS DATE DESCRIPTION
COPYRIGHT ©BLUEWATER BUILDING DESIGNSBLUEWATER BUILDING DESIGNSBLUEWATER BUILDING DESIGNSBLUEWATER BUILDING DESIGNS
Use figured dimensions at all times. Refer enquiries to STROUD HOMES.All dimensions to be verified on site prior to construction. All work to comply with Local
Authority regulations & BCA.All drawings copyright to STROUD HOMES.
JDM
QBSA LIC. 1212800
A3A3A3A3
LOT 7 SIREC WAY BURLEIGH HEADS
UNIT 2
Site Plan
2.4.20
100 A
PRELIMINARY2.4.20
EAST
WEST
SUMMERBREEZES
PMN
E-
SE
WINTERSUNAM
SUMMERSUN
AM
SU
MM
ER
BR
EE
ZES
AM
S-
SE
SUMMER STORMS
WINTER WINDS W- SWSUMMER
SUN
PM W
INT
ER
SU
NP
M
SOUTH
TRUE NORTH
M.G
.A.
LOT AREA =
HOUSE FOOTPRINT =
SITE COVERAGE = 50%
500m²
1000m²
GL = 00.00
CUT = <000mm
FILL = <000mm
FL = REFER TO ENGINEERS
1. EARTHWORKSa) Cut and fill indicated on plan may vary at construction stage and builder is to verify and adjust as required.b) Any variation at construction stageis to comply with Council policy on earthworks/drainage for residential sites.c) Site works indicated on this plan are for construction purposes only.2. RETAINING WALLSa) All retaining walls are to comply with Council policy on retaining walls and embankments on residential building sites.b) Position of retaining wall may vary and must be verified by builder prior to commencement.c) Any variation at construction stage to comply with Council policy.3. CONTOURS AND LEVELSa) Contours and levels shown on plan are taken from levels supplied by contour surveyor and no responsibility is taken for accuracy or cut and fill levels.
NOTE:STORMWATER DRAINAGE CALCULATED FOR BUILDING ROOF AREAS AND/OR PAVED AREAS SHOWN ON THIS PROPOSED DEVELOPMENT ONLY AND MAY NOT BE ADEQUATE FOR ANY SUBSEQUENT ROOF OR PAVED AREAS.
MIN 100x75 DOWNPIPES ( EACH TO DRAIN MAX 40.00m sq. ROOF AREA) DISCHARING INTO 100mm sq. S/W DRAINAGE PIPEWORK (EACH RUN CARRYING MAX CAPACITY OF 8 litres/sec) MIN GRADE TO RUBBLE PITS ON SITE TO BE 1%
NOTE:
ALL FENCING, RETAINING WALLS,
LANDSCAPING & COVENANT
APPROVAL BY OWNER.
REFER TO BUILDERS SPECIFICATION
FOR DETAILS
BAL 12.5 BUSH FIRE REQUIREMENTS
• VENTS AND WEEPHOLES TO BE SCREENED WITH MESH AT A 2mm APERTURE
• FLYSCREENS TO BE METAL WITH A 2mm APERTURE
• WINDOW GLAZING LESS THAN 400mm FROM GROUND TO HAVE 4mm SAFETY GLASS
• EXTERNAL TIMBER DOORS TO BE SOLID CORE OF 35mm min. THICKNESS. GLAZING IN DOORS TO BE 4mm SAFETY GLASS. WEATHER STRIPS TO BE FITTED TO THE BOTTOM OF DOOR
• PANEL LIFT GARAGE DOORS TO BE FITTED WITH WEATHER STRIPS
• ALL ROOF TYPES TO BE SEALED TO PREVENT OPENING S OF 3mm. ALL ROOF OPENINGS TO HAVE EMBER GUARDS
• TILED AND COLORBOND ROOFS TO BE FULLY SARKED
• EAVE VENTS TO HAVE EMBER GUARDS WITH A 2mm APERTURE
NOTE:
NATURAL GAS SUPPLY TO BE CONNECTED
TO THE HOUSE IF AVAILABLE
TO BE CONFIRMED
REFER TO UNIT 1 PLANS FOR SITE PLAN
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Tap
Tap
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
FDFD
S
S
S
S
S
S
10
20
LIVING
DINING
KITCHEN
ENTRY
PORCH
GARAGE
L'DRY
WCP'TRY
ALFRESCO
F
720
820
82
0
82
0
720
SHELVES
2448 AUTO PANEL LIFT
820
70580070
7024807040907098070145070139070113070162070
703400429070144070260070162070
13700
70142070580070
255052105940
69070
73070
5720
2400
70 703890
704000
1030
9750
702150
705900
70530
70705900
7053070
1090
70990
70
705900
702750
70
8860
LINEN LINEN
1200
0906 SF 0624 F
690
1300
OH
C
SERVICES
21
15
SD
3000
2124 SD
2106 DH-FB2106 DH-FB
2106 DH-FB 2106 DH-FB
980 70 4090 70 2480 70
720 3000 70 2480 70
13700
BEAM
BE
AM
720
140sq. HWD
TIMBER
POSTS
21
24
SD
5.9
0 m
5.80 m
3.8
9 m3.40 m
890
820
WM
D
ryr.
DP
DP
DP DP
DP
DP
DP
90mm STEP
90mm STEP
702150
3930
701970
70
108.42m2
Ground Floor
14.80m2
Alfresco
2.62m2
Porch
MASTER BEDROOM
WIR
ENS
BED 2
BED 3
STUDY
BED 4BATH
WC
82
0
72
0
720
ROBE
BATH1520
RETREAT
LINEN
1600
0906 SF0912 SF0450 x 0900 SF
1518 F1506 DH1518 F 1506 DH
1518 F1506 DH
4.00 m
4.0
0 m
1000m
m wall
1000m
m wall
ROBE
12
18
SF
1218 SF
770
820
820
82
0
1800
21
00
09
24
FS
SF
3.0
0 m
3.25 m
2.9
3 m
3.00 m
2.2
5 m
4.07 m
3.0
0 m
3.47 m
70 3000 70 1690 70 970 70 1000 70 4070 70
70 3000 70 1690 70 2040 70530
70 3470 70
11150
70900
701000
3500
701000
703000
70
890
702110
701820
701100
7053070
2880
70
890
704000
1080
701700
701800
70
890
8860
70 3000 1000 70 1730 70 1000 70 4070 70
70 4000 70550
70 3250 70 3000 70
703000
701000
704500
70900
70
703000
703470
70950
701980
70 703000
702250
70530
702930
70690
9750
4690 3390 3070
11150
18
00
DP
DP
DPDP
DP
DP
98.36m2
First Floor
Natter Pty Ltd t/as Stroud Homes Gold CoastQBCC Licence: 108 1372 Phone: 07 5607 48501638 Gold Coast Highway, Burleigh Heads
PHONE: 0410 648 059ABN: 25 367 288 616
EMAIL: [email protected]
CLIENT:
SITE
DETAILS:
PROJECT:
JOB No:
ISSUE:DWG No:
SCALE:
DATE:
DRAWN:
A
ISS DATE DESCRIPTION
COPYRIGHT ©BLUEWATER BUILDING DESIGNSBLUEWATER BUILDING DESIGNSBLUEWATER BUILDING DESIGNSBLUEWATER BUILDING DESIGNS
Use figured dimensions at all times. Refer enquiries to STROUD HOMES.All dimensions to be verified on site prior to construction. All work to comply with Local
Authority regulations & BCA.All drawings copyright to STROUD HOMES.
JDM
QBSA LIC. 1212800
A3A3A3A3
As indicated
LOT 7 SIREC WAY BURLEIGH HEADS
UNIT 2
Floor Plan - UNIT 2
2.4.20
300 A
PRELIMINARY2.4.20
Elevation 3
Elevation 4
Elevation 1
Elevation 2
1 : 100
Floor Plan - Ground Floor
Area ScheduleName Area Perimeter
Alfresco 14.80 m² 15.20 m
First Floor 98.36 m² 41.80 m
Ground Floor 108.42 m² 46.66 m
Porch 2.62 m² 6.86 m
Grand total: 4 224.19 m²
1 : 500
Area Plan
1 : 100
Floor Plan - First Floor
1 : 500
First FloorUNIT 2
UNIT 2
Ground Floor
Plate Height
Head Height
Pad Level
First Floor
Head Height - FirstPlate Height - First
21002400
5.00°
8.00°
SELECTED
COLORBOND
ROOF
SELECTED
COLORBOND
ROOF
SELECTED
COLORBOND
ROOF
SELECTED
NEWPORT
CLADDING
SELECTED AXON
CLADDING
SELECTED
NEWPORT
CLADDING
9.00°
140sq. HWD
TIMBER
POSTS
300
2448 AUTO PANEL LIFT
320
2740
2100
600
400
600
600
Ground Floor
Plate Height
Head Height
Pad Level
First Floor
Head Height - FirstPlate Height - First
Natter Pty Ltd t/as Stroud Homes Gold CoastQBCC Licence: 108 1372 Phone: 07 5607 48501638 Gold Coast Highway, Burleigh Heads
PHONE: 0410 648 059ABN: 25 367 288 616
EMAIL: [email protected]
CLIENT:
SITE
DETAILS:
PROJECT:
JOB No:
ISSUE:DWG No:
SCALE:
DATE:
DRAWN:
A
ISS DATE DESCRIPTION
COPYRIGHT ©BLUEWATER BUILDING DESIGNSBLUEWATER BUILDING DESIGNSBLUEWATER BUILDING DESIGNSBLUEWATER BUILDING DESIGNS
Use figured dimensions at all times. Refer enquiries to STROUD HOMES.All dimensions to be verified on site prior to construction. All work to comply with Local
Authority regulations & BCA.All drawings copyright to STROUD HOMES.
JDM
QBSA LIC. 1212800
A3A3A3A3
1 : 100
LOT 7 SIREC WAY BURLEIGH HEADS
UNIT 2
Elevations - UNIT 2
2.4.20
301 A
PRELIMINARY2.4.20
1 : 100
Elevation 1
1 : 100
Elevation 2
1 : 100
Elevation 3
1 : 100
Elevation 4
UNIT 2
Tap
Tap
FDFD
S
S
S
S
S
S
2-WAY
2-WAY
ME
TE
R B
OX
2-WAY
2-WAY
Natter Pty Ltd t/as Stroud Homes Gold CoastQBCC Licence: 108 1372 Phone: 07 5607 48501638 Gold Coast Highway, Burleigh Heads
PHONE: 0410 648 059ABN: 25 367 288 616
EMAIL: [email protected]
CLIENT:
SITE
DETAILS:
PROJECT:
JOB No:
ISSUE:DWG No:
SCALE:
DATE:
DRAWN:
A
ISS DATE DESCRIPTION
COPYRIGHT ©BLUEWATER BUILDING DESIGNSBLUEWATER BUILDING DESIGNSBLUEWATER BUILDING DESIGNSBLUEWATER BUILDING DESIGNS
Use figured dimensions at all times. Refer enquiries to STROUD HOMES.All dimensions to be verified on site prior to construction. All work to comply with Local
Authority regulations & BCA.All drawings copyright to STROUD HOMES.
JDM
QBSA LIC. 1212800
A3A3A3A3
1 : 100
LOT 7 SIREC WAY BURLEIGH HEADS
UNIT 2
Electrical Plan
2.4.20
400 A
PRELIMINARY2.4.20
Electrical FixturesDescription Count
2 - Way Light Switch 2
2 Bulb & Sensor Spot Light 1
Ceiling Fan 5
Data Point 1
Double Fluroesent 1
Double Power Outlet 14
Double Power Outlet w/ USB 1
Downlight w/ energy efficient bulb 32
Exhaust Fan 2
External Bunker Wall Light 2
Meter Box 1
Seperate Sensor 1
Single Power Outlet 4
Smoke Alarm 6
Telephone Outlet 2
TV Outlet 2
Two Globe Heat Lamp & Exhaust Fan 2
Weatherproof Double Power Outlet 1
S
ELECTRICAL LEGEND
DOWNLIGHT w/ ENERGY EFFICIENT BULBS
DOUBLE FLUORESCENT
OYSTER LIGHT
POWER OUTLETS
TELEVISION OUTLET
EXHAUST FAN
WEATHERPROOF POWER OUTLETS
TELEPHONE OUTLET
SMOKE ALARM
CEILING FAN
EXTERNAL BUNKER WALL LIGHT
TWO GLOBE HEAT LAMP & EXHAUST FAN
GAS METER
SEPERATE SENSOR
EXTERNAL 2 BULB & SENSOR SPOT LIGHT
REVERSE CYCLE AIR CONDITIONER
LIGHT SWITCHES TO BE 1150 ABOVE FFL.WALL LIGHTS TO BE 1800 ABOVE FFL.
POWER POINTS TO BE 300 ABOVE FFL.UNLESS STATED OTHERWISE.
FEATURE LIGHT
DATA POINT
NBN HOME DISTRIBUTOR
METER BOX
PENDANT LIGHT
DOUBLE POWER OUTLET w/ USB
DOWNLIGHT w/ BUILT-IN SENSOR
F CIRCULAR FLURO
1 : 100
Electrical - Ground1 : 100
Electrical - First
UNIT 2
70 1440 70 1290 3000
70
600
1000
800
70 1440 70 980 70 1040 2200
70
1090
70
990
70
KITCHEN
FOHC
F/S GC
OHC
DW
SHELVES
P'TRY
OH
CW
M
Dry
r.
L'DRY
70
2750
70
70 600 1020 70
PWD
SERVICES
70 2230 70
300
70
70
990
70
495
495
Natter Pty Ltd t/as Stroud Homes Gold CoastQBCC Licence: 108 1372 Phone: 07 5607 48501638 Gold Coast Highway, Burleigh Heads
PHONE: 0410 648 059ABN: 25 367 288 616
EMAIL: [email protected]
CLIENT:
SITE
DETAILS:
PROJECT:
JOB No:
ISSUE:DWG No:
SCALE:
DATE:
DRAWN:
A
ISS DATE DESCRIPTION
COPYRIGHT ©BLUEWATER BUILDING DESIGNSBLUEWATER BUILDING DESIGNSBLUEWATER BUILDING DESIGNSBLUEWATER BUILDING DESIGNS
Use figured dimensions at all times. Refer enquiries to STROUD HOMES.All dimensions to be verified on site prior to construction. All work to comply with Local
Authority regulations & BCA.All drawings copyright to STROUD HOMES.
JDM
QBSA LIC. 1212800
A3A3A3A3
1 : 50
LOT 7 SIREC WAY BURLEIGH HEADS
UNIT 2
Internal Elevations
2.4.20
500 A
PRELIMINARY2.4.20
3D Kitchen1 : 50
Callout Kitchen
1 : 50
Callout Laundry 3D Laundry1 : 50
Callout PWD 3D PWD
UNIT 2
FD
FD
BATH
BATH 1520
70 900 790 70
70
900
100
1000
880
70
70
2000
880
70
70 1690 70
ENSUITE
70 1600 100 1300 70
70
1800
70
70
900
900
70
70 3000 70450
450
WC
450
450
70
900
70
70 2040 70
Natter Pty Ltd t/as Stroud Homes Gold CoastQBCC Licence: 108 1372 Phone: 07 5607 48501638 Gold Coast Highway, Burleigh Heads
PHONE: 0410 648 059ABN: 25 367 288 616
EMAIL: [email protected]
CLIENT:
SITE
DETAILS:
PROJECT:
JOB No:
ISSUE:DWG No:
SCALE:
DATE:
DRAWN:
A
ISS DATE DESCRIPTION
COPYRIGHT ©BLUEWATER BUILDING DESIGNSBLUEWATER BUILDING DESIGNSBLUEWATER BUILDING DESIGNSBLUEWATER BUILDING DESIGNS
Use figured dimensions at all times. Refer enquiries to STROUD HOMES.All dimensions to be verified on site prior to construction. All work to comply with Local
Authority regulations & BCA.All drawings copyright to STROUD HOMES.
JDM
QBSA LIC. 1212800
A3A3A3A3
1 : 50
LOT 7 SIREC WAY BURLEIGH HEADS
UNIT 2
Internal Elevations
2.4.20
501 A
PRELIMINARY2.4.20
1 : 50
Callout Bathroom
1 : 50
Callout Ensuite
1 : 50
Callout WC
3D Bathroom
3D Ensuite
3D WC
3D Stairs
3D Stairs SectionUNIT 2