loca laboratories in research centre Řež

13
LOCA Laboratories in Research Centre Řež Roman Mohyla Research Centre Řež

Upload: others

Post on 03-Dec-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

LOCA Laboratories

in

Research Centre Řež

Roman Mohyla

Research Centre Řež

Who we are and what we do

-Testing components for NPP

-Testing new materials for NPP (geopolymers, concrete)

1

Laboratories

1. High Voltage laboratory

2. Gamma irradiation laboratory

3. LOCA laboratory

2

1. High Voltage Laboratory

Withstand Voltage Test

50 kV AC / 100 kV DC

Insulation Resistance Test

Test in water pool with controlled water temperature up to 90°C

Possibbility to test large and heavy specimens (crane)

Acredited laboratory

3

2. Gamma Irradiation Laboratory

Irradiation source 60Co, activity 200 TBq

Experimental box with possibility to irradiate with various

temperatures

Temperature aging irradiated components

Laboratory designed for small samples

4

2. Gamma Irradiation Laboratory

5

2. Gamma Irradiation Laboratory – experimental

box

Sample holder 150x200 mm

Max. height irradiated samples 160 mm

Lenght of the box 450 mm

-196°C/ +400°C and high vacuum.

Polymers, electronic devices and

equipment, plastic components,

geopolymers

6

3. LOCA Laboratory

LOCA (Loss of Coolant Accident)

Designed for large specimens

Testing cables, motors, pumps, sensors,...

7

3. LOCA Laboratory

Main parts of LOCA technology:

8

Pressure vessels for tested samples

Steam boiler for generating steam

Spray solution system

Control room

Large LOCA Small LOCA

3. LOCA Laboratory

9

Large LOCA

V = 3.5 m3

Tmax = 300 C

pmax = 20 bar

Small LOCA

V = 0.6 m3

Tmax = 300 C

pmax = 20 bar

H2 Chamber

V = 0,3 m3

Tmax = 800 C

Pmax = 20 bar

3. Thermodynamic profiles of LOCA Laboratory

10

Large LOCA Small LOCA

3. Thermodynamic profile of Large LOCA

11

0

5

10

15

20

25

30

0

50

100

150

200

250

300

350

12.11.2017 12:47:31 12.11.2017 12:48:58 12.11.2017 12:50:24 12.11.2017 12:51:50 12.11.2017 12:53:17 12.11.2017 12:54:43 12.11.2017 12:56:10

300°C 20bara

Teploty Hodnota 11 Teploty Hodnota 12 Teploty Hodnota 13 Tlaky Hodnota 1

54s 23s

Pressure drop 0,2bar for 23s

12

Thank you for your attention

http://cvrez.cz/

http://susen2020.cz/

Roman Mohyla

[email protected]