CBCB 1.5:1 pilot ratio, standard capacity counterbalancevalve
1
CBEB 1.5:1 pilot ratio, standard capacity counterbalancevalve
2
CBGB 1.5:1 pilot ratio, standard capacity counterbalancevalve
4
CBIB 1.5:1 pilot ratio, standard capacity counterbalancevalve
5
CBCY 2:1 pilot ratio, standard capacity counterbalancevalve
7
CBEY 2:1 pilot ratio, standard capacity counterbalancevalve
8
CBGY 2:1 pilot ratio, standard capacity counterbalancevalve
9
CBIY 2:1 pilot ratio, standard capacity counterbalancevalve
11
CBCL 2.3:1 pilot ratio, standard capacity counterbalancevalve
13
CBEL 2.3:1 pilot ratio, standard capacity counterbalancevalve
14
CBGL 2.3:1 pilot ratio, standard capacity counterbalancevalve
16
CBIL 2.3:1 pilot ratio, standard capacity counterbalancevalve
18
CBCA 3:1 pilot ratio, standard capacity counterbalancevalve
20
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
Table of Contents
CBEA 3:1 pilot ratio, standard capacity counterbalancevalve
21
CBGA 3:1 pilot ratio, standard capacity counterbalancevalve
22
CBIA 3:1 pilot ratio, standard capacity counterbalancevalve
23
CBCG 4.5:1 pilot ratio, standard capacity counterbalancevalve
25
CBEG 4.5:1 pilot ratio, standard capacity counterbalancevalve
27
CBGG 4.5:1 pilot ratio, standard capacity counterbalancevalve
29
CBIG 4.5:1 pilot ratio, standard capacity counterbalancevalve
31
CBCH 10:1 pilot ratio, standard capacity counterbalancevalve
33
CBEH 10:1 pilot ratio, standard capacity counterbalancevalve
35
CBGH 10:1 pilot ratio, standard capacity counterbalancevalve
37
CBIH 10:1 pilot ratio, standard capacity counterbalancevalve
39
CBBB 1.5:1 pilot ratio, semi-restrictive counterbalancevalve
40
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
Table of Contents
CBDB 1.5:1 pilot ratio, semi-restrictive counterbalancevalve
41
CBFB 1.5:1 pilot ratio, semi-restrictive counterbalancevalve
43
CBBL 2.3:1 pilot ratio, semi-restrictive counterbalancevalve
44
CBDL 2.3:1 pilot ratio, semi-restrictive counterbalancevalve
45
CBFL 2.3:1 pilot ratio, semi-restrictive counterbalancevalve
47
CBBC 3:1 pilot ratio, semi-restrictive counterbalancevalve
48
CBDC 3:1 pilot ratio, semi-restrictive counterbalancevalve
49
CBFC 3:1 pilot ratio, semi-restrictive counterbalancevalve
51
CBBD 4.5:1 pilot ratio, semi-restrictive counterbalancevalve
52
CBDD 4.5:1 pilot ratio, semi-restrictive counterbalancevalve
53
CBFD 4.5:1 pilot ratio, semi-restrictive counterbalancevalve
55
CBBY 2:1 pilot ratio, restrictive counterbalancevalve
56
CBBA 3:1 pilot ratio, restrictive counterbalancevalve
57
CBDA 3:1 pilot ratio, restrictive counterbalancevalve
58
CBFA 3:1 pilot ratio, restrictive counterbalancevalve
59
CBHA 3:1 pilot ratio, restrictive counterbalancevalve
60
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
Table of Contents
CBBG 4.5:1 pilot ratio, restrictive counterbalancevalve
62
CBDG 4.5:1 pilot ratio, restrictive counterbalancevalve
63
CBFG 4.5:1 pilot ratio, restrictive counterbalancevalve
65
CBHG 4.5:1 pilot ratio, restrictive counterbalancevalve
67
CBAB 1.5:1 pilot ratio, ultra-restrictive counterbalancevalve
69
CBAA 3:1 pilot ratio, ultra-restrictive counterbalancevalve
70
CBAG 4.5:1 pilot ratio, ultra-restrictive counterbalancevalve
71
CBAH 10:1 pilot ratio, ultra-restrictive counterbalancevalve
72
CBCLX Fixed setting, 2.3:1 pilot ratio, standard capacity counterbalancevalve
73
CBCAX Fixed setting, 3:1 pilot ratio, standard capacity counterbalancevalve
74
CBEAX Fixed setting, 3:1 pilot ratio, standard capacity counterbalancevalve
75
CBCGX Fixed setting, 4.5:1 pilot ratio, standard capacity counterbalancevalve
76
CBCHX Fixed setting, 10:1 pilot ratio, standard capacity counterbalancevalve
77
CBBLX Fixed setting, 2.3:1 pilot ratio, semi-restrictive counterbalancevalve
78
CBBCX Fixed setting, 3:1 pilot ratio, semi-restrictive counterbalancevalve
79
CBDCX Fixed setting, 3:1 pilot ratio, semi-restrictive counterbalancevalve
80
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
Table of Contents
CBBDX Fixed setting, 4.5:1 pilot ratio, semi-restrictive counterbalancevalve
81
CBDDX Fixed setting, 4.5:1 pilot ratio, semi-restrictive counterbalancevalve
82
CBBAX Fixed setting, 3:1 pilot ratio, restrictive counterbalancevalve
83
CBDAX Fixed setting, 3:1 pilot ratio, restrictive counterbalancevalve
84
CBBGX Fixed setting, 4.5:1 pilot ratio, restrictive counterbalancevalve
85
CBDGX Fixed setting, 4.5:1 pilot ratio, restrictive counterbalancevalve
86
CBABX Fixed setting, 1.5:1 pilot ratio, ultra-restrictive counterbalancevalve
87
CBAAX Fixed setting, 3:1 pilot ratio, ultra-restrictive counterbalancevalve
88
CBAGX Fixed setting, 4.5:1 pilot ratio, ultra-restrictive counterbalancevalve
89
CABK 1:1 pilot ratio, vented counterbalance valve - atmosphericallyreferenced
90
CACK 1:1 pilot ratio, vented counterbalance valve - atmosphericallyreferenced
91
CAEK 1:1 pilot ratio, vented counterbalance valve - atmosphericallyreferenced
92
CAGK 1:1 pilot ratio, vented counterbalance valve - atmosphericallyreferenced
93
CAIK 1:1 pilot ratio, vented counterbalance valve - atmosphericallyreferenced
94
CACL 2:1 pilot ratio, vented counterbalance valve - atmosphericallyreferenced
95
CAEL 2:1 pilot ratio, vented counterbalance valve - atmosphericallyreferenced
96
CAGL 2:1 pilot ratio, vented counterbalance valve - atmosphericallyreferenced
97
CAIL 2:1 pilot ratio, vented counterbalance valve - atmosphericallyreferenced
98
CACA 3:1 pilot ratio, vented counterbalance valve - atmosphericallyreferenced
99
CAEA 3:1 pilot ratio, vented counterbalance valve - atmosphericallyreferenced
100
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
Table of Contents
CAGA 3:1 pilot ratio, vented counterbalance valve - atmosphericallyreferenced
101
CAIA 3:1 pilot ratio, vented counterbalance valve - atmosphericallyreferenced
102
CABG 4.5:1 pilot ratio, vented counterbalance valve - atmosphericallyreferenced
103
CACG 5:1 pilot ratio, vented counterbalance valve - atmosphericallyreferenced
104
CAEG 5:1 pilot ratio, vented counterbalance valve - atmosphericallyreferenced
105
CAGG 5:1 pilot ratio, vented counterbalance valve - atmosphericallyreferenced
106
CAIG 5:1 pilot ratio, vented counterbalance valve - atmosphericallyreferenced
107
CWCK 1:1 pilot ratio, vented counterbalancevalve
108
CWEK 1:1 pilot ratio, vented counterbalancevalve
109
CWGK 1:1 pilot ratio, vented counterbalancevalve
110
CWIK 1:1 pilot ratio, vented counterbalancevalve
111
CWCL 2:1 pilot ratio, vented counterbalancevalve
112
CWEL 2:1 pilot ratio, vented counterbalancevalve
113
CWGL 2:1 pilot ratio, vented counterbalancevalve
114
CWIL 2:1 pilot ratio, vented counterbalancevalve
115
CWCA 3:1 pilot ratio, vented counterbalancevalve
116
CWEA 3:1 pilot ratio, vented counterbalancevalve
117
CWGA 3:1 pilot ratio, vented counterbalancevalve
118
CWIA 3:1 pilot ratio, vented counterbalancevalve
119
CWCG 5:1 pilot ratio, vented counterbalancevalve
120
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
Table of Contents
CWEG 5:1 pilot ratio, vented counterbalancevalve
121
CWGG 5:1 pilot ratio, vented counterbalancevalve
122
CWIG 5:1 pilot ratio, vented counterbalancevalve
123
MBEM Balanced load controlvalve
124
MBGM Balanced load controlvalve
125
MBIM Balanced load controlvalve
126
MWEM Vented, balanced, load controlvalve
127
MWGM Vented, balanced, load controlvalve
128
MWIM Vented, balanced, load controlvalve
129
MBDB 1.5:1 pilot ratio, load reactive load controlvalve
130
MBEB 1.5:1 pilot ratio, load reactive load controlvalve
131
MBGB 1.5:1 pilot ratio, load reactive load controlvalve
132
MBIB 1.5:1 pilot ratio, load reactive load controlvalve
133
MBDA 3:1 pilot ratio, load reactive load controlvalve
134
MBEA 3:1 pilot ratio, load reactive load controlvalve
135
MBGA 3:1 pilot ratio, load reactive load controlvalve
136
MBIA 3:1 pilot ratio, load reactive load controlvalve
137
MBDG 4.5:1 pilot ratio, load reactive load controlvalve
138
MBEG 4.5:1 pilot ratio, load reactive load controlvalve
139
MBGG 4.5:1 pilot ratio, load reactive load controlvalve
140
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
Table of Contents
MBIG 4.5:1 pilot ratio, load reactive load controlvalve
141
MBEBX Fixed setting, 1.5:1 pilot ratio, load reactive load controlvalve
142
MBGBX Fixed setting, 1.5:1 pilot ratio, load reactive load controlvalve
143
MBIBX Fixed setting, 1.5:1 pilot ratio, load reactive load controlvalve
144
MBEAX Fixed setting, 3:1 pilot ratio, load reactive load controlvalve
145
MBGAX Fixed setting, 3:1 pilot ratio, load reactive load controlvalve
146
MBIAX Fixed setting, 3:1 pilot ratio, load reactive load controlvalve
147
MBEGX Fixed setting, 4.5:1 pilot ratio, load reactive load controlvalve
148
MBGGX Fixed setting, 4.5:1 pilot ratio, load reactive load controlvalve
149
MBIGX Fixed setting, 4.5:1 pilot ratio, load reactive load controlvalve
150
MWEB Vented, 1.5:1 pilot ratio, load reactive, load controlvalve
151
MWGB Vented, 1.5:1 pilot ratio, load reactive, load controlvalve
152
MWEA Vented, 3:1 pilot ratio, load reactive, load controlvalve
153
MWGA Vented, 3:1 pilot ratio, load reactive, load controlvalve
154
MWIA Vented, 3:1 pilot ratio, load reactive load controlvalve
155
MWEG Vented, 4.5:1 pilot ratio, load reactive, load controlvalve
156
MWGG Vented, 4.5:1 pilot ratio, load reactive, load controlvalve
157
MWIG Vented, 4.5:1 pilot ratio, load reactive load controlvalve
158
MWEBX Vented, fixed setting, 1.5:1 pilot ratio, load reactive, load controlvalve
159
MWGBX Vented, fixed setting, 1.5:1 pilot ratio, load reactive, load controlvalve
160
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
Table of Contents
MWIBX Fixed setting, vented, 1.5:1 pilot ratio, load reactive load controlvalve
161
MWEAX Vented, fixed setting, 3:1 pilot ratio, load reactive, load controlvalve
162
MWGAX Vented, fixed setting, 3:1 pilot ratio, load reactive, load controlvalve
163
MWIAX Fixed setting, vented, 3:1 pilot ratio, load reactive load controlvalve
164
MWEGX Vented, fixed setting, 4.5:1 pilot ratio, load reactive, load controlvalve
165
MWGGX Vented, fixed setting, 4.5:1 pilot ratio, load reactive, load controlvalve
166
MWIGX Fixed setting, vented, 4.5:1 pilot ratio, load reactive load controlvalve
167
MBDP LoadMatch™ counterbalancevalve
168
MBEP LoadMatch™ counterbalancevalve
169
MBGP LoadMatch™ counterbalancevalve
170
MADP Atmospherically referenced, LoadMatch™ counterbalancevalve
171
MAEP Atmospherically referenced, LoadMatch™ counterbalancevalve
172
MAGP Atmospherically referenced, LoadMatch™ counterbalancevalve
173
MWDP Vented LoadMatch™ counterbalancevalve
174
MWEP Vented LoadMatch™ counterbalancevalve
175
MWGP Vented LoadMatch™ counterbalancevalve
176
MWIB Vented, 1.5:1 pilot ratio, load reactive load controlvalve
177
CKBB Pilot-to-open check valve with standardpilot
178
CKBG Flush mount pilot-to-open check valve with sealedpilot
179
CKCB Pilot-to-open check valve with standardpilot
180
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
Table of Contents
CKEB Pilot-to-open check valve with standardpilot
181
CKGB Pilot-to-open check valve with standardpilot
182
CKIB Pilot-to-open check valve with standardpilot
183
CKBD Pilot-to-open check valve with sealedpilot
184
CKCD Pilot-to-open check valve with sealedpilot
185
CKED Pilot-to-open check valve with sealedpilot
186
CKGD Pilot-to-open check valve with sealedpilot
187
CKID Pilot-to-open check valve with sealedpilot
188
CVCV Vented pilot-to-open checkvalve
189
CVEV Vented pilot-to-open checkvalve
190
CVGV Vented pilot-to-open checkvalve
191
CVIV Vented pilot-to-open checkvalve
192
CKCV Vented pilot-to-open check valve - atmosphericallyreferenced
193
CKEV Vented pilot-to-open check valve - atmosphericallyreferenced
194
CKGV Vented pilot-to-open check valve - atmosphericallyreferenced
195
CKIV Vented pilot-to-open check valve - atmosphericallyreferenced
196
CNCE Pilot-to-open check valve with bypassorifice
197
CNEE Pilot-to-open check valve with bypassorifice
198
CNGE Pilot-to-open check valve with bypassorifice
199
CABN 7:1 pilot ratio, vented counterbalance - valve atmosphericallyreferenced
200
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
..............................................................................................................................................................
Table of Contents
CACH 10:1 pilot ratio, vented counterbalance - valve atmosphericallyreferenced
201
CBDBX Fixed setting, 1.5:1 pilot ratio, semi-restrictive counterbalancevalve
202
CBDHX Fixed setting, 10:1 pilot ratio, restrictive counterbalancevalve
203
CEBA 3:1 pilot ratio, restrictive, LoadAdaptive™ counterbalancevalve
204
CEBC 3:1 pilot ratio, semi-restrictive, LoadAdaptive™ counterbalancevalve
205
CECA 3:1 pilot ratio, standard capacity, LoadAdaptive™ counterbalancevalve
206
MBDN 8:1 pilot ratio, load reactive load controlvalve
207
Cavity Information
Series Ports Cavities
Series Z Cartridges3/8-24 UNF Cartridge Thread5 mm Valve Hex Size11 - 14 Nm Valve Installation Torque
2-Port T-382A
Series P CartridgesM16 Cartridge Thread22,2 mm Valve Hex Size27 - 33 Nm Valve Installation Torque
2-Port2-Port (Deep)3-Port
T-8AT-8DPT-9A
Series 0 CartridgesM16 Cartridge Thread19,1 mm Valve Hex Size25,4 mm Valve Hex Size27 - 33 Nm Valve Installation Torque
2-Port2-Port (Deep)3-Port
T-162AT-162DPT-163A
Series 1 CartridgesM20 Cartridge Thread22,2 mm Valve Hex Size41 - 47 Nm Valve Installation Torque
2-Port2-Port3-Port4-Port4-Port6-Port
T-10AT-13AT-11AT-21AT-31AT-61A
Series 2 Cartridges1"-14 UNS Cartridge Thread28,6 mm Valve Hex Size61 - 68 Nm Valve Installation Torque
2-Port2-Port3-Port4-Port4-Port4-Port (Dual path)6-Port6-Port
T-3AT-5AT-2AT-22AT-32AT-52ADT-52AT-62A
Series 3 CartridgesM36 Cartridge Thread31,8 mm Valve Hex Size203 - 217 Nm Valve Installation Torque
2-Port3-Port4-Port4-Port4-Port (Dual path)6-Port6-Port
T-16AT-17AT-23AT-33AT-53ADT-53AT-63A
Series 4 CartridgesM48 Cartridge Thread41,3 mm Valve Hex Size474 - 508 Nm Valve Installation Torque
2-Port2-Port (Undercut)3-Port3-Port (Undercut)4-Port4-Port (Undercut)4-Port4-Port (Dual path)6-Port6-Port
T-18AT-18AUT-19AT-19AUT-24AT-24AUT-34AT-54ADT-54AT-64A
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 1 of 207
MODELCBCB
1.5:1 pilot ratio, standard capacity counterbalance valveSERIES 1 / CAPACITY: 60 L/min. / CAVITY: T-11A
3-Port Non-vented
3-Port Non-vented, Fixed Setting
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 1.5:1Maximum Recommended Load Pressure at Maximum Setting 215 barMaximum Setting 280 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990011007Seal kit - Cartridge Polyurethane: 990011002Seal kit - Cartridge Viton: 990011006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi w/25 psi Check (70 -
280 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard Setting
A 1000 - 4000 psi w/4 psi Check (70 -280 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
B 400 - 1500 psi w/4 psi Check (28 - 105bar w/ 0,3 bar Check), 1000 psi (70bar) Standard Setting
I 400 - 1500 psi w/25 psi Check (28 -105 bar w/ 1,7 bar Check), 1000 psi (70bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/CBCB
Model Code Example: CBCBLHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 2 of 207
MODELCBEB
1.5:1 pilot ratio, standard capacity counterbalance valveSERIES 2 / CAPACITY: 120 L/min. / CAVITY: T-2A
3-Port Non-vented
3-Port Non-vented, Fixed Setting
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 1.5:1Maximum Recommended Load Pressure at Maximum Setting 215 barMaximum Setting 280 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990202007Seal kit - Cartridge EPDM: 990202014Seal kit - Cartridge Polyurethane: 990002002Seal kit - Cartridge Viton: 990202006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(N)SEAL MATERIALN Buna-NE EPDMV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi w/25 psi Check (70 -
280 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard Setting
A 1000 - 4000 psi w/4 psi Check (70 -280 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
B 400 - 1500 psi w/4 psi Check (28 - 105bar w/ 0,3 bar Check), 1000 psi (70bar) Standard Setting
I 400 - 1500 psi w/25 psi Check (28 -
snhy.com/CBEB
Model Code Example: CBEBLHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 3 of 207
I 400 - 1500 psi w/25 psi Check (28 -105 bar w/ 1,7 bar Check), 1000 psi (70bar) Standard Setting
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 4 of 207
MODELCBGB
1.5:1 pilot ratio, standard capacity counterbalance valveSERIES 3 / CAPACITY: 240 L/min. / CAVITY: T-17A
3-Port Non-vented
3-Port Non-vented, Fixed Setting
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 1.5:1Maximum Recommended Load Pressure at Maximum Setting 215 barMaximum Setting 280 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990017007Seal kit - Cartridge Polyurethane: 990017002Seal kit - Cartridge Viton: 990017006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi w/25 psi Check (70 -
280 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard Setting
A 1000 - 4000 psi w/4 psi Check (70 -280 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
B 400 - 1500 psi w/4 psi Check (28 - 105bar w/ 0,3 bar Check), 1000 psi (70bar) Standard Setting
I 400 - 1500 psi w/25 psi Check (28 -105 bar w/ 1,7 bar Check), 1000 psi (70bar) Standard Setting
snhy.com/CBGB
Model Code Example: CBGBLHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 5 of 207
MODELCBIB
1.5:1 pilot ratio, standard capacity counterbalance valveSERIES 4 / CAPACITY: 480 L/min. / CAVITY: T-19A
3-Port Non-vented
3-Port Non-vented, Fixed Setting
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 1.5:1Maximum Recommended Load Pressure at Maximum Setting 215 barMaximum Setting 280 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 19,1 mmLocknut Torque 35 - 40 NmSeal kit - Cartridge Buna: 990019007Seal kit - Cartridge Polyurethane: 990019002Seal kit - Cartridge Viton: 990019006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/LH Mild Steel, Zinc-Nickel
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi w/25 psi Check (70 -
280 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard Setting
A 1000 - 4000 psi w/4 psi Check (70 -280 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
B 400 - 1500 psi w/4 psi Check (28 - 105bar w/ 0,3 bar Check), 1000 psi (70bar) Standard Setting
I 400 - 1500 psi w/25 psi Check (28 -105 bar w/ 1,7 bar Check), 1000 psi (70bar) Standard Setting
snhy.com/CBIB
Model Code Example: CBIBLHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 6 of 207
bar) Standard Setting
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 7 of 207
MODELCBC�
2:1 pilot ratio, standard capacity counterbalance valveSERIES 1 / CAPACITY: 60 L/min. / CAVITY: T-11A
3-Port Non-vented
3-Port Non-vented, Fixed Setting
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 2:1Maximum Recommended Load Pressure at Maximum Setting 215 barMaximum Setting 280 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990011007Seal kit - Cartridge Polyurethane: 990011002Seal kit - Cartridge Viton: 990011006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi w/25 psi Check (70 -
280 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard Setting
A 1000 - 4000 psi w/4 psi Check (70 -280 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
B 400 - 1500 psi w/4 psi Check (28 - 105bar w/ 0,3 bar Check), 1000 psi (70bar) Standard Setting
I 400 - 1500 psi w/25 psi Check (28 -105 bar w/ 1,7 bar Check), 1000 psi (70bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/CBCY
Model Code Example: CBCYLHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 8 of 207
MODELCBE✁
2:1 pilot ratio, standard capacity counterbalance valveSERIES 2 / CAPACITY: 120 L/min. / CAVITY: T-2A
3-Port Non-vented
3-Port Non-vented, Fixed Setting
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 2:1Maximum Recommended Load Pressure at Maximum Setting 215 barMaximum Setting 280 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990202007Seal kit - Cartridge Polyurethane: 990002002Seal kit - Cartridge Viton: 990202006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi w/25 psi Check (70 -
280 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard Setting
A 1000 - 4000 psi w/4 psi Check (70 -280 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
B 400 - 1500 psi w/4 psi Check (28 - 105bar w/ 0,3 bar Check), 1000 psi (70bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/CBEY
Model Code Example: CBEYLHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 9 of 207
MODELCBGY
2:1 pilot ratio, standard capacity counterbalance valveSERIES 3 / CAPACITY: 240 L/min. / CAVITY: T-17A
3-Port Non-vented
3-Port Non-vented, Fixed Setting
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 2:1Maximum Recommended Load Pressure at Maximum Setting 215 barMaximum Setting 280 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990017007Seal kit - Cartridge Polyurethane: 990017002Seal kit - Cartridge Viton: 990017006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi w/25 psi Check (70 -
280 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard Setting
A 1000 - 4000 psi w/4 psi Check (70 -280 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
B 400 - 1500 psi w/4 psi Check (28 - 105bar w/ 0,3 bar Check), 1000 psi (70bar) Standard Setting
I 400 - 1500 psi w/25 psi Check (28 -105 bar w/ 1,7 bar Check), 1000 psi (70bar) Standard Setting
snhy.com/CBGY
Model Code Example: CBGYLHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 10 of 207
bar) Standard Setting
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 11 of 207
MODELCBIY
2:1 pilot ratio, standard capacity counterbalance valveSERIES 4 / CAPACITY: 480 L/min. / CAVITY: T-19A
3-Port Non-vented
3-Port Non-vented, Fixed Setting
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 2:1Maximum Recommended Load Pressure at Maximum Setting 215 barMaximum Setting 280 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 19,1 mmLocknut Torque 35 - 40 NmSeal kit - Cartridge Buna: 990019007Seal kit - Cartridge Polyurethane: 990019002Seal kit - Cartridge Viton: 990019006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/LH Mild Steel, Zinc-Nickel
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi w/25 psi Check (70 -
280 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard Setting
A 1000 - 4000 psi w/4 psi Check (70 -280 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
B 400 - 1500 psi w/4 psi Check (28 - 105bar w/ 0,3 bar Check), 1000 psi (70bar) Standard Setting
I 400 - 1500 psi w/25 psi Check (28 -105 bar w/ 1,7 bar Check), 1000 psi (70bar) Standard Setting
snhy.com/CBIY
Model Code Example: CBIYLHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 12 of 207
bar) Standard Setting
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 13 of 207
MODELCBCL
2.3:1 pilot ratio, standard capacity counterbalance valveSERIES 1 / CAPACITY: 60 L/min. / CAVITY: T-11A
3-Port Non-vented
3-Port Non-vented, Fixed Setting
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 2.3:1Maximum Recommended Load Pressure at Maximum Setting 270 barMaximum Setting 350 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990011007Seal kit - Cartridge EPDM: 990011014Seal kit - Cartridge Polyurethane: 990011002Seal kit - Cartridge Viton: 990011006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(J)FUNCTIONAL SETTING RANGEJ 2000 - 5000 psi w/25 psi Check (140 -
350 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard Setting
C 2000 - 5000 psi w/4 psi Check (140 -350 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
D 1000 - 2500 psi w/4 psi Check (70 -175 bar w/ 0,3 bar Check), 2000 psi(140 bar) Standard SettingK 1000 - 2500 psi w/25 psi Check (70 -175 bar w/ 1,7 bar Check), 2000 psi(140 bar) Standard Setting
(N)SEAL MATERIALN Buna-NE EPDMV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/CBCL
Model Code Example: CBCLLJNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 14 of 207
MODELCBEL
2.3:1 pilot ratio, standard capacity counterbalance valveSERIES 2 / CAPACITY: 120 L/min. / CAVITY: T-2A
3-Port Non-vented
3-Port Non-vented, Fixed Setting
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 2.3:1Maximum Recommended Load Pressure at Maximum Setting 270 barMaximum Setting 350 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990202007Seal kit - Cartridge Polyurethane: 990002002Seal kit - Cartridge Viton: 990202006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
(J)FUNCTIONAL SETTING RANGEJ 2000 - 5000 psi w/25 psi Check (140 -
350 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard SettingC 2000 - 5000 psi w/4 psi Check (140 -350 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
D 1000 - 2500 psi w/4 psi Check (70 -175 bar w/ 0,3 bar Check), 2000 psi(140 bar) Standard Setting
K 1000 - 2500 psi w/25 psi Check (70 -175 bar w/ 1,7 bar Check), 2000 psi
snhy.com/CBEL
Model Code Example: CBELLJNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 15 of 207
175 bar w/ 1,7 bar Check), 2000 psi(140 bar) Standard Setting
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 16 of 207
MODELCBGL
2.3:1 pilot ratio, standard capacity counterbalance valveSERIES 3 / CAPACITY: 240 L/min. / CAVITY: T-17A
3-Port Non-vented
3-Port Non-vented, Fixed Setting
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 2.3:1Maximum Recommended Load Pressure at Maximum Setting 270 barMaximum Setting 350 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990017007Seal kit - Cartridge EPDM: 990017014Seal kit - Cartridge Polyurethane: 990017002Seal kit - Cartridge Viton: 990017006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(N)SEAL MATERIALN Buna-NE EPDMV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
(J)FUNCTIONAL SETTING RANGEJ 2000 - 5000 psi w/25 psi Check (140 -
350 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard Setting
C 2000 - 5000 psi w/4 psi Check (140 -350 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
D 1000 - 2500 psi w/4 psi Check (70 -175 bar w/ 0,3 bar Check), 2000 psi(140 bar) Standard Setting
K 1000 - 2500 psi w/25 psi Check (70 -
snhy.com/CBGL
Model Code Example: CBGLLJNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 17 of 207
K 1000 - 2500 psi w/25 psi Check (70 -175 bar w/ 1,7 bar Check), 2000 psi(140 bar) Standard Setting
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 18 of 207
MODELCBIL
2.3:1 pilot ratio, standard capacity counterbalance valveSERIES 4 / CAPACITY: 480 L/min. / CAVITY: T-19A
3-Port Non-vented
3-Port Non-vented, Fixed Setting
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 2.3:1Maximum Recommended Load Pressure at Maximum Setting 270 barMaximum Setting 350 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 19,1 mmLocknut Torque 35 - 40 NmSeal kit - Cartridge Buna: 990019007Seal kit - Cartridge Polyurethane: 990019002Seal kit - Cartridge Viton: 990019006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
(J)FUNCTIONAL SETTING RANGEJ 2000 - 5000 psi w/25 psi Check (140 -
350 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard Setting
C 2000 - 5000 psi w/4 psi Check (140 -350 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
D 1000 - 2500 psi w/4 psi Check (70 -175 bar w/ 0,3 bar Check), 2000 psi(140 bar) Standard Setting
K 1000 - 2500 psi w/25 psi Check (70 -175 bar w/ 1,7 bar Check), 2000 psi(140 bar) Standard Setting
snhy.com/CBIL
Model Code Example: CBILLJNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 19 of 207
(140 bar) Standard Setting
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 20 of 207
MODELCBCA
3:1 pilot ratio, standard capacity counterbalance valveSERIES 1 / CAPACITY: 60 L/min. / CAVITY: T-11A
3-Port Non-vented
3-Port Non-vented, Fixed Setting
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 3:1Maximum Recommended Load Pressure at Maximum Setting 215 barMaximum Setting 280 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990011007Seal kit - Cartridge EPDM: 990011014Seal kit - Cartridge Polyurethane: 990011002Seal kit - Cartridge Viton: 990011006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi w/25 psi Check (70 -
280 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard Setting
A 1000 - 4000 psi w/4 psi Check (70 -280 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
B 400 - 1500 psi w/4 psi Check (28 - 105bar w/ 0,3 bar Check), 1000 psi (70bar) Standard Setting
I 400 - 1500 psi w/25 psi Check (28 -105 bar w/ 1,7 bar Check), 1000 psi (70bar) Standard Setting
(N)SEAL MATERIALN Buna-NE EPDMV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/CBCA
Model Code Example: CBCALHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 21 of 207
MODELCBEA
3:1 pilot ratio, standard capacity counterbalance valveSERIES 2 / CAPACITY: 120 L/min. / CAVITY: T-2A
3-Port Non-vented
3-Port Non-vented, Fixed Setting
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 3:1Maximum Recommended Load Pressure at Maximum Setting 215 barMaximum Setting 280 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990202007Seal kit - Cartridge EPDM: 990202014Seal kit - Cartridge Polyurethane: 990002002Seal kit - Cartridge Viton: 990202006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(N)SEAL MATERIALN Buna-NE EPDMV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi w/25 psi Check (70 -
280 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard Setting
A 1000 - 4000 psi w/4 psi Check (70 -280 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
B 400 - 1500 psi w/4 psi Check (28 - 105bar w/ 0,3 bar Check), 1000 psi (70bar) Standard Setting
I 400 - 1500 psi w/25 psi Check (28 -105 bar w/ 1,7 bar Check), 1000 psi (70bar) Standard Setting
snhy.com/CBEA
Model Code Example: CBEALHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 22 of 207
MODELCBGA
3:1 pilot ratio, standard capacity counterbalance valveSERIES 3 / CAPACITY: 240 L/min. / CAVITY: T-17A
3-Port Non-vented
3-Port Non-vented, Fixed Setting
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 3:1Maximum Recommended Load Pressure at Maximum Setting 215 barMaximum Setting 280 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990017007Seal kit - Cartridge Polyurethane: 990017002Seal kit - Cartridge Viton: 990017006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi w/25 psi Check (70 -
280 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard Setting
A 1000 - 4000 psi w/4 psi Check (70 -280 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
B 400 - 1500 psi w/4 psi Check (28 - 105bar w/ 0,3 bar Check), 1000 psi (70bar) Standard Setting
I 400 - 1500 psi w/25 psi Check (28 -105 bar w/ 1,7 bar Check), 1000 psi (70bar) Standard Setting
snhy.com/CBGA
Model Code Example: CBGALHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 23 of 207
MODELCBIA
3:1 pilot ratio, standard capacity counterbalance valveSERIES 4 / CAPACITY: 480 L/min. / CAVITY: T-19A
3-Port Non-vented
3-Port Non-vented, Fixed Setting
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 3:1Maximum Recommended Load Pressure at Maximum Setting 215 barMaximum Setting 280 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 19,1 mmLocknut Torque 35 - 40 NmSeal kit - Cartridge Buna: 990019007Seal kit - Cartridge Polyurethane: 990019002Seal kit - Cartridge Viton: 990019006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi w/25 psi Check (70 -
280 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard Setting
A 1000 - 4000 psi w/4 psi Check (70 -280 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
B 400 - 1500 psi w/4 psi Check (28 - 105bar w/ 0,3 bar Check), 1000 psi (70bar) Standard Setting
I 400 - 1500 psi w/25 psi Check (28 -105 bar w/ 1,7 bar Check), 1000 psi (70bar) Standard Setting
snhy.com/CBIA
Model Code Example: CBIALHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 24 of 207
bar) Standard Setting
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 25 of 207
MODELCBCG
4.5:1 pilot ratio, standard capacity counterbalance valveSERIES 1 / CAPACITY: 60 L/min. / CAVITY: T-11A
3-Port Non-vented
3-Port Non-vented, Fixed Setting
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 4.5:1Maximum Recommended Load Pressure at Maximum Setting 270 barMaximum Setting 350 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990011007Seal kit - Cartridge EPDM: 990011014Seal kit - Cartridge Polyurethane: 990011002Seal kit - Cartridge Viton: 990011006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(N)SEAL MATERIALN Buna-NE EPDMV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
(J)FUNCTIONAL SETTING RANGEJ 2000 - 5000 psi w/25 psi Check (140 -
350 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard Setting
C 2000 - 5000 psi w/4 psi Check (140 -350 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
D 1000 - 2500 psi w/4 psi Check (70 -175 bar w/ 0,3 bar Check), 2000 psi(140 bar) Standard Setting
K 1000 - 2500 psi w/25 psi Check (70 -175 bar w/ 1,7 bar Check), 2000 psi(140 bar) Standard Setting
snhy.com/CBCG
A fixed setting version is available for this model. To view this product page, use Sun's search box and type in the 4 letter model code. The search resultwill include the fixed setting version.NOTES
Model Code Example: CBCGLJNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 26 of 207
(140 bar) Standard Setting
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 27 of 207
MODELCBEG
4.5:1 pilot ratio, standard capacity counterbalance valveSERIES 2 / CAPACITY: 120 L/min. / CAVITY: T-2A
3-Port Non-vented
3-Port Non-vented, Fixed Setting
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 4.5:1Maximum Recommended Load Pressure at Maximum Setting 270 barMaximum Setting 350 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990202007Seal kit - Cartridge EPDM: 990202014Seal kit - Cartridge Polyurethane: 990002002Seal kit - Cartridge Viton: 990202006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
(J)FUNCTIONAL SETTING RANGEJ 2000 - 5000 psi w/25 psi Check (140 -
350 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard Setting
C 2000 - 5000 psi w/4 psi Check (140 -350 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
D 1000 - 2500 psi w/4 psi Check (70 -175 bar w/ 0,3 bar Check), 2000 psi(140 bar) Standard Setting
snhy.com/CBEG
Model Code Example: CBEGLJNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 28 of 207
(140 bar) Standard SettingK 1000 - 2500 psi w/25 psi Check (70 -
175 bar w/ 1,7 bar Check), 2000 psi(140 bar) Standard Setting
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 29 of 207
MODELCBGG
4.5:1 pilot ratio, standard capacity counterbalance valveSERIES 3 / CAPACITY: 240 L/min. / CAVITY: T-17A
3-Port Non-vented
3-Port Non-vented, Fixed Setting
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 4.5:1Maximum Recommended Load Pressure at Maximum Setting 270 barMaximum Setting 350 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990017007Seal kit - Cartridge EPDM: 990017014Seal kit - Cartridge Polyurethane: 990017002Seal kit - Cartridge Viton: 990017006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(N)SEAL MATERIALN Buna-NE EPDMV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
(J)FUNCTIONAL SETTING RANGEJ 2000 - 5000 psi w/25 psi Check (140 -
350 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard Setting
C 2000 - 5000 psi w/4 psi Check (140 -350 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
D 1000 - 2500 psi w/4 psi Check (70 -175 bar w/ 0,3 bar Check), 2000 psi
snhy.com/CBGG
Model Code Example: CBGGLJNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 30 of 207
175 bar w/ 0,3 bar Check), 2000 psi(140 bar) Standard Setting
K 1000 - 2500 psi w/25 psi Check (70 -175 bar w/ 1,7 bar Check), 2000 psi(140 bar) Standard Setting
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 31 of 207
MODELCBIG
4.5:1 pilot ratio, standard capacity counterbalance valveSERIES 4 / CAPACITY: 480 L/min. / CAVITY: T-19A
3-Port Non-vented
3-Port Non-vented, Fixed Setting
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 4.5:1Maximum Recommended Load Pressure at Maximum Setting 270 barMaximum Setting 350 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 19,1 mmLocknut Torque 35 - 40 NmSeal kit - Cartridge Buna: 990019007Seal kit - Cartridge Polyurethane: 990019002Seal kit - Cartridge Viton: 990019006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
(J)FUNCTIONAL SETTING RANGEJ 2000 - 5000 psi w/25 psi Check (140 -
350 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard Setting
C 2000 - 5000 psi w/4 psi Check (140 -350 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
D 1000 - 2500 psi w/4 psi Check (70 -175 bar w/ 0,3 bar Check), 2000 psi(140 bar) Standard Setting
K 1000 - 2500 psi w/25 psi Check (70 -175 bar w/ 1,7 bar Check), 2000 psi(140 bar) Standard Setting
snhy.com/CBIG
Model Code Example: CBIGLJNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 32 of 207
(140 bar) Standard Setting
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 33 of 207
MODELCBCH
10:1 pilot ratio, standard capacity counterbalance valveSERIES 1 / CAPACITY: 60 L/min. / CAVITY: T-11A
3-Port Non-vented
3-Port Non-vented, Fixed Setting
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 10:1Maximum Recommended Load Pressure at Maximum Setting 270 barMaximum Setting 350 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990011007Seal kit - Cartridge Polyurethane: 990011002Seal kit - Cartridge Viton: 990011006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
(J)FUNCTIONAL SETTING RANGEJ 2000 - 5000 psi w/25 psi Check (140 -
350 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard Setting
C 2000 - 5000 psi w/4 psi Check (140 -350 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
D 1000 - 2500 psi w/4 psi Check (70 -175 bar w/ 0,3 bar Check), 2000 psi(140 bar) Standard Setting
K 1000 - 2500 psi w/25 psi Check (70 -175 bar w/ 1,7 bar Check), 2000 psi
snhy.com/CBCH
Model Code Example: CBCHLJNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 34 of 207
175 bar w/ 1,7 bar Check), 2000 psi(140 bar) Standard Setting
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 35 of 207
MODELCBEH
10:1 pilot ratio, standard capacity counterbalance valveSERIES 2 / CAPACITY: 120 L/min. / CAVITY: T-2A
3-Port Non-vented
3-Port Non-vented, Fixed SettingCounterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 10:1Maximum Recommended Load Pressure at Maximum Setting 270 barMaximum Setting 350 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990202007Seal kit - Cartridge Polyurethane: 990002002Seal kit - Cartridge Viton: 990202006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
(J)FUNCTIONAL SETTING RANGEJ 2000 - 5000 psi w/25 psi Check (140 -
350 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard Setting
C 2000 - 5000 psi w/4 psi Check (140 -350 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
snhy.com/CBEH
Model Code Example: CBEHLJNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 36 of 207
(210 bar) Standard SettingD 1000 - 2500 psi w/4 psi Check (70 -
175 bar w/ 0,3 bar Check), 2000 psi(140 bar) Standard Setting
K 1000 - 2500 psi w/25 psi Check (70 -175 bar w/ 1,7 bar Check), 2000 psi(140 bar) Standard Setting
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 37 of 207
MODELCBGH
10:1 pilot ratio, standard capacity counterbalance valveSERIES 3 / CAPACITY: 240 L/min. / CAVITY: T-17A
3-Port Non-vented
3-Port Non-vented, Fixed Setting
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 10:1Maximum Recommended Load Pressure at Maximum Setting 270 barMaximum Setting 350 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990017007Seal kit - Cartridge Polyurethane: 990017002Seal kit - Cartridge Viton: 990017006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
(J)FUNCTIONAL SETTING RANGEJ 2000 - 5000 psi w/25 psi Check (140 -
350 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard Setting
C 2000 - 5000 psi w/4 psi Check (140 -350 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
D 1000 - 2500 psi w/4 psi Check (70 -175 bar w/ 0,3 bar Check), 2000 psi(140 bar) Standard Setting
K 1000 - 2500 psi w/25 psi Check (70 -175 bar w/ 1,7 bar Check), 2000 psi(140 bar) Standard Setting
snhy.com/CBGH
Model Code Example: CBGHLJNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 38 of 207
(140 bar) Standard Setting
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 39 of 207
MODELCBIH
10:1 pilot ratio, standard capacity counterbalance valveSERIES 4 / CAPACITY: 480 L/min. / CAVITY: T-19A
3-Port Non-vented
3-Port Non-vented, Fixed Setting
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 10:1Maximum Recommended Load Pressure at Maximum Setting 270 barMaximum Setting 350 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 19,1 mmLocknut Torque 35 - 40 NmSeal kit - Cartridge Buna: 990019007Seal kit - Cartridge Polyurethane: 990019002Seal kit - Cartridge Viton: 990019006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
(J)FUNCTIONAL SETTING RANGEJ 2000 - 5000 psi w/25 psi Check (140 -
350 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard Setting
C 2000 - 5000 psi w/4 psi Check (140 -350 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
D 1000 - 2500 psi w/4 psi Check (70 -175 bar w/ 0,3 bar Check), 2000 psi(140 bar) Standard Setting
K 1000 - 2500 psi w/25 psi Check (70 -175 bar w/ 1,7 bar Check), 2000 psi(140 bar) Standard Setting
snhy.com/CBIH
Model Code Example: CBIHLJNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 40 of 207
MODELCBBB
1.5:1 pilot ratio, semi-restrictive counterbalance valveSERIES 1 / CAPACITY: 40 L/min. / CAVITY: T-11A
3-Port Non-vented
3-Port Non-vented, Fixed Setting
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 1.5:1Maximum Recommended Load Pressure at Maximum Setting 215 barMaximum Setting 280 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990011007Seal kit - Cartridge Polyurethane: 990011002Seal kit - Cartridge Viton: 990011006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi w/25 psi Check (70 -
280 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard Setting
A 1000 - 4000 psi w/4 psi Check (70 -280 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
B 400 - 1500 psi w/4 psi Check (28 - 105bar w/ 0,3 bar Check), 1000 psi (70bar) Standard Setting
I 400 - 1500 psi w/25 psi Check (28 -105 bar w/ 1,7 bar Check), 1000 psi (70bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/CBBB
Model Code Example: CBBBLHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 41 of 207
MODELCBDB
1.5:1 pilot ratio, semi-restrictive counterbalance valveSERIES 2 / CAPACITY: 80 L/min. / CAVITY: T-2A
3-Port Non-vented
3-Port Non-vented, Fixed Setting
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 1.5:1Maximum Recommended Load Pressure at Maximum Setting 215 barMaximum Setting 280 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990202007Seal kit - Cartridge Polyurethane: 990002002Seal kit - Cartridge Viton: 990202006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi w/25 psi Check (70 -
280 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard SettingA 1000 - 4000 psi w/4 psi Check (70 -280 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
B 400 - 1500 psi w/4 psi Check (28 - 105bar w/ 0,3 bar Check), 1000 psi (70bar) Standard Setting
I 400 - 1500 psi w/25 psi Check (28 -105 bar w/ 1,7 bar Check), 1000 psi (70
snhy.com/CBDB
Model Code Example: CBDBLHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 42 of 207
105 bar w/ 1,7 bar Check), 1000 psi (70bar) Standard Setting
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 43 of 207
MODELCBFB
1.5:1 pilot ratio, semi-restrictive counterbalance valveSERIES 3 / CAPACITY: 160 L/min. / CAVITY: T-17A
3-Port Non-vented
3-Port Non-vented, Fixed Setting
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 1.5:1Maximum Recommended Load Pressure at Maximum Setting 215 barMaximum Setting 280 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990017007Seal kit - Cartridge Polyurethane: 990017002Seal kit - Cartridge Viton: 990017006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/LH Mild Steel, Zinc-Nickel
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi w/25 psi Check (70 -
280 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard Setting
A 1000 - 4000 psi w/4 psi Check (70 -280 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
B 400 - 1500 psi w/4 psi Check (28 - 105bar w/ 0,3 bar Check), 1000 psi (70bar) Standard Setting
I 400 - 1500 psi w/25 psi Check (28 -105 bar w/ 1,7 bar Check), 1000 psi (70bar) Standard Setting
snhy.com/CBFB
Model Code Example: CBFBLHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 44 of 207
MODELCBBL
2.3:1 pilot ratio, semi-restrictive counterbalance valveSERIES 1 / CAPACITY: 40 L/min. / CAVITY: T-11A
3-Port Non-vented
3-Port Non-vented, Fixed Setting
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 2.3:1Maximum Recommended Load Pressure at Maximum Setting 270 barMaximum Setting 350 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990011007Seal kit - Cartridge Polyurethane: 990011002Seal kit - Cartridge Viton: 990011006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(J)FUNCTIONAL SETTING RANGEJ 2000 - 5000 psi w/25 psi Check (140 -
350 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard Setting
C 2000 - 5000 psi w/4 psi Check (140 -350 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
D 1000 - 2500 psi w/4 psi Check (70 -175 bar w/ 0,3 bar Check), 2000 psi(140 bar) Standard Setting
K 1000 - 2500 psi w/25 psi Check (70 -175 bar w/ 1,7 bar Check), 2000 psi(140 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/CBBL
A fixed setting version is available for this model. To view this product page, use Sun's search box and type in CBBLX and click on the resulting link.NOTES
Model Code Example: CBBLLJNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 45 of 207
MODELCBDL
2.3:1 pilot ratio, semi-restrictive counterbalance valveSERIES 2 / CAPACITY: 80 L/min. / CAVITY: T-2A
3-Port Non-vented
3-Port Non-vented, Fixed Setting
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 2.3:1Maximum Recommended Load Pressure at Maximum Setting 270 barMaximum Setting 350 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990202007Seal kit - Cartridge Polyurethane: 990002002Seal kit - Cartridge Viton: 990202006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
(J)FUNCTIONAL SETTING RANGEJ 2000 - 5000 psi w/25 psi Check (140 -
350 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard SettingC 2000 - 5000 psi w/4 psi Check (140 -350 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
D 1000 - 2500 psi w/4 psi Check (70 -175 bar w/ 0,3 bar Check), 2000 psi(140 bar) Standard Setting
K 1000 - 2500 psi w/25 psi Check (70 -175 bar w/ 1,7 bar Check), 2000 psi
snhy.com/CBDL
Model Code Example: CBDLLJNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 46 of 207
175 bar w/ 1,7 bar Check), 2000 psi(140 bar) Standard Setting
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 47 of 207
MODELCBFL
2.3:1 pilot ratio, semi-restrictive counterbalance valveSERIES 3 / CAPACITY: 160 L/min. / CAVITY: T-17A
3-Port Non-vented
3-Port Non-vented, Fixed Setting
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 2.3:1Maximum Recommended Load Pressure at Maximum Setting 270 barMaximum Setting 350 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990017007Seal kit - Cartridge Polyurethane: 990017002Seal kit - Cartridge Viton: 990017006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/LH Mild Steel, Zinc-Nickel
(J)FUNCTIONAL SETTING RANGEJ 2000 - 5000 psi w/25 psi Check (140 -
350 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard Setting
C 2000 - 5000 psi w/4 psi Check (140 -350 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
D 1000 - 2500 psi w/4 psi Check (70 -175 bar w/ 0,3 bar Check), 2000 psi(140 bar) Standard Setting
K 1000 - 2500 psi w/25 psi Check (70 -175 bar w/ 1,7 bar Check), 2000 psi(140 bar) Standard Setting
snhy.com/CBFL
Model Code Example: CBFLLJNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 48 of 207
MODELCBBC
3:1 pilot ratio, semi-restrictive counterbalance valveSERIES 1 / CAPACITY: 40 L/min. / CAVITY: T-11A
3-Port Non-vented
3-Port Non-vented, Fixed Setting
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 3:1Maximum Recommended Load Pressure at Maximum Setting 215 barMaximum Setting 280 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990011007Seal kit - Cartridge Polyurethane: 990011002Seal kit - Cartridge Viton: 990011006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi w/25 psi Check (70 -
280 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard Setting
A 1000 - 4000 psi w/4 psi Check (70 -280 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
B 400 - 1500 psi w/4 psi Check (28 - 105bar w/ 0,3 bar Check), 1000 psi (70bar) Standard Setting
I 400 - 1500 psi w/25 psi Check (28 -105 bar w/ 1,7 bar Check), 1000 psi (70bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/CBBC
Model Code Example: CBBCLHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 49 of 207
MODELCBDC
3:1 pilot ratio, semi-restrictive counterbalance valveSERIES 2 / CAPACITY: 80 L/min. / CAVITY: T-2A
3-Port Non-vented
3-Port Non-vented, Fixed Setting
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 3:1Maximum Recommended Load Pressure at Maximum Setting 215 barMaximum Setting 280 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990202007Seal kit - Cartridge Polyurethane: 990002002Seal kit - Cartridge Viton: 990202006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi w/25 psi Check (70 -
280 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard SettingA 1000 - 4000 psi w/4 psi Check (70 -280 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
B 400 - 1500 psi w/4 psi Check (28 - 105bar w/ 0,3 bar Check), 1000 psi (70bar) Standard Setting
I 400 - 1500 psi w/25 psi Check (28 -105 bar w/ 1,7 bar Check), 1000 psi (70
snhy.com/CBDC
Model Code Example: CBDCLHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 50 of 207
105 bar w/ 1,7 bar Check), 1000 psi (70bar) Standard Setting
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 51 of 207
MODELCBFC
3:1 pilot ratio, semi-restrictive counterbalance valveSERIES 3 / CAPACITY: 160 L/min. / CAVITY: T-17A
3-Port Non-vented
3-Port Non-vented, Fixed Setting
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 3:1Maximum Recommended Load Pressure at Maximum Setting 215 barMaximum Setting 280 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990017007Seal kit - Cartridge Polyurethane: 990017002Seal kit - Cartridge Viton: 990017006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi w/25 psi Check (70 -
280 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard Setting
A 1000 - 4000 psi w/4 psi Check (70 -280 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
B 400 - 1500 psi w/4 psi Check (28 - 105bar w/ 0,3 bar Check), 1000 psi (70bar) Standard Setting
I 400 - 1500 psi w/25 psi Check (28 -105 bar w/ 1,7 bar Check), 1000 psi (70bar) Standard Setting
snhy.com/CBFC
Model Code Example: CBFCLHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 52 of 207
MODELCBBD
4.5:1 pilot ratio, semi-restrictive counterbalance valveSERIES 1 / CAPACITY: 40 L/min. / CAVITY: T-11A
3-Port Non-vented
3-Port Non-vented, Fixed Setting
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 4.5:1Maximum Recommended Load Pressure at Maximum Setting 270 barMaximum Setting 350 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990011007Seal kit - Cartridge EPDM: 990011014Seal kit - Cartridge Polyurethane: 990011002Seal kit - Cartridge Viton: 990011009
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(J)FUNCTIONAL SETTING RANGEJ 2000 - 5000 psi w/25 psi Check (140 -
350 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard Setting
C 2000 - 5000 psi w/4 psi Check (140 -350 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
D 1000 - 2500 psi w/4 psi Check (70 -175 bar w/ 0,3 bar Check), 2000 psi(140 bar) Standard Setting
K 1000 - 2500 psi w/25 psi Check (70 -175 bar w/ 1,7 bar Check), 2000 psi(140 bar) Standard Setting
(N)SEAL MATERIALN Buna-NE EPDMV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/CBBD
A fixed setting version is available for this model. To view this product page, use Sun's search box and type in CBBDX and click on the resulting link.NOTES
Model Code Example: CBBDLJNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 53 of 207
MODELCBDD
4.5:1 pilot ratio, semi-restrictive counterbalance valveSERIES 2 / CAPACITY: 80 L/min. / CAVITY: T-2A
3-Port Non-vented
3-Port Non-vented, Fixed Setting
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 4.5:1Maximum Recommended Load Pressure at Maximum Setting 270 barMaximum Setting 350 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990202007Seal kit - Cartridge Polyurethane: 990002002Seal kit - Cartridge Viton: 990202006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
(J)FUNCTIONAL SETTING RANGEJ 2000 - 5000 psi w/25 psi Check (140 -
350 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard Setting
C 2000 - 5000 psi w/4 psi Check (140 -350 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
D 1000 - 2500 psi w/4 psi Check (70 -175 bar w/ 0,3 bar Check), 2000 psi(140 bar) Standard Setting
K 1000 - 2500 psi w/25 psi Check (70 -175 bar w/ 1,7 bar Check), 2000 psi(140 bar) Standard Setting
snhy.com/CBDD
Model Code Example: CBDDLJNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 54 of 207
(140 bar) Standard Setting
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 55 of 207
MODELCBFD
4.5:1 pilot ratio, semi-restrictive counterbalance valveSERIES 3 / CAPACITY: 160 L/min. / CAVITY: T-17A
3-Port Non-vented
3-Port Non-vented, Fixed Setting
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 4.5:1Maximum Recommended Load Pressure at Maximum Setting 270 barMaximum Setting 350 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990017007Seal kit - Cartridge Polyurethane: 990017002Seal kit - Cartridge Viton: 990017006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
(J)FUNCTIONAL SETTING RANGEJ 2000 - 5000 psi w/25 psi Check (140 -
350 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard Setting
C 2000 - 5000 psi w/4 psi Check (140 -350 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
D 1000 - 2500 psi w/4 psi Check (70 -175 bar w/ 0,3 bar Check), 2000 psi(140 bar) Standard Setting
K 1000 - 2500 psi w/25 psi Check (70 -175 bar w/ 1,7 bar Check), 2000 psi(140 bar) Standard Setting
snhy.com/CBFD
Model Code Example: CBFDLJNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 56 of 207
MODELCBB✂
2:1 pilot ratio, restrictive counterbalance valveSERIES 1 / CAPACIT✄: 20 L/min. / CAVITY: T-11A
3-Port Non-vented
3-Port Non-vented, Fixed Setting
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 2:1Maximum Recommended Load Pressure at Maximum Setting 215 barMaximum Setting 280 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990011007Seal kit - Cartridge Polyurethane: 990011002Seal kit - Cartridge Viton: 990011006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi w/25 psi Check (70 -
280 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard Setting
A 1000 - 4000 psi w/4 psi Check (70 -280 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
B 400 - 1500 psi w/4 psi Check (28 - 105bar w/ 0,3 bar Check), 1000 psi (70bar) Standard Setting
I 400 - 1500 psi w/25 psi Check (28 -105 bar w/ 1,7 bar Check), 1000 psi (70bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/CBBY
Model Code Example: CBBYLHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 57 of 207
MODELCBBA
3:1 pilot ratio, restrictive counterbalance valveSERIES 1 / CAPACITY: 20 L/min. / CAVITY: T-11A
3-Port Non-vented
3-Port Non-vented, Fixed Setting
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 3:1Maximum Recommended Load Pressure at Maximum Setting 215 barMaximum Setting 280 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990011007Seal kit - Cartridge Polyurethane: 990011002Seal kit - Cartridge Viton: 990011006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi w/25 psi Check (70 -
280 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard Setting
A 1000 - 4000 psi w/4 psi Check (70 -280 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
B 400 - 1500 psi w/4 psi Check (28 - 105bar w/ 0,3 bar Check), 1000 psi (70bar) Standard Setting
I 400 - 1500 psi w/25 psi Check (28 -105 bar w/ 1,7 bar Check), 1000 psi (70bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/CBBA
Model Code Example: CBBALHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 58 of 207
MODELCBDA
3:1 pilot ratio, restrictive counterbalance valveSERIES 2 / CAPACITY: 30 L/min. / CAVITY: T-2A
3-Port Non-vented
3-Port Non-vented, Fixed Setting
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 3:1Maximum Recommended Load Pressure at Maximum Setting 215 barMaximum Setting 280 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990202007Seal kit - Cartridge Polyurethane: 990002002Seal kit - Cartridge Viton: 990202006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi w/25 psi Check (70 -
280 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard Setting
A 1000 - 4000 psi w/4 psi Check (70 -280 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
B 400 - 1500 psi w/4 psi Check (28 - 105bar w/ 0,3 bar Check), 1000 psi (70bar) Standard Setting
I 400 - 1500 psi w/25 psi Check (28 -105 bar w/ 1,7 bar Check), 1000 psi (70bar) Standard Setting
snhy.com/CBDA
Model Code Example: CBDALHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 59 of 207
MODELCBFA
3:1 pilot ratio, restrictive counterbalance valveSERIES 3 / CAPACITY: 60 L/min. / CAVITY: T-17A
3-Port Non-vented
3-Port Non-vented, Fixed Setting
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 3:1Maximum Recommended Load Pressure at Maximum Setting 215 barMaximum Setting 280 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990017007Seal kit - Cartridge Polyurethane: 990017002Seal kit - Cartridge Viton: 990017006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi w/25 psi Check (70 -
280 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard Setting
A 1000 - 4000 psi w/4 psi Check (70 -280 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard SettingB 400 - 1500 psi w/4 psi Check (28 - 105bar w/ 0,3 bar Check), 1000 psi (70bar) Standard Setting
I 400 - 1500 psi w/25 psi Check (28 -105 bar w/ 1,7 bar Check), 1000 psi (70bar) Standard Setting
snhy.com/CBFA
Model Code Example: CBFALHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 60 of 207
MODELCBHA
3:1 pilot ratio, restrictive counterbalance valveSERIES 4 / CAPACITY: 80 L/min. / CAVITY: T-19A
3-Port Non-vented
3-Port Non-vented, Fixed Setting
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 3:1Maximum Recommended Load Pressure at Maximum Setting 215 barMaximum Setting 280 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 19,1 mmLocknut Torque 35 - 40 NmSeal kit - Cartridge Buna: 990019007Seal kit - Cartridge Polyurethane: 990019002Seal kit - Cartridge Viton: 990019006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(N)SEAL MATERIALN Buna-NV Viton
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi w/25 psi Check (70 -
280 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard Setting
A 1000 - 4000 psi w/4 psi Check (70 -280 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
B 400 - 1500 psi w/4 psi Check (28 - 105bar w/ 0,3 bar Check), 1000 psi (70bar) Standard Setting
I 400 - 1500 psi w/25 psi Check (28 -105 bar w/ 1,7 bar Check), 1000 psi (70bar) Standard Setting
snhy.com/CBHA
Model Code Example: CBHALHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 61 of 207
bar) Standard Setting
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 62 of 207
MODELCBBG
4.5:1 pilot ratio, restrictive counterbalance valveSERIES 1 / CAPACITY: 20 L/min. / CAVITY: T-11A
3-Port Non-vented
3-Port Non-vented, Fixed Setting
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 4.5:1Maximum Recommended Load Pressure at Maximum Setting 270 barMaximum Setting 350 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990011007Seal kit - Cartridge Polyurethane: 990011002Seal kit - Cartridge Viton: 990011006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(J)FUNCTIONAL SETTING RANGEJ 2000 - 5000 psi w/25 psi Check (140 -
350 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard Setting
C 2000 - 5000 psi w/4 psi Check (140 -350 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
D 1000 - 2500 psi w/4 psi Check (70 -175 bar w/ 0,3 bar Check), 2000 psi(140 bar) Standard Setting
K 1000 - 2500 psi w/25 psi Check (70 -175 bar w/ 1,7 bar Check), 2000 psi(140 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/CBBG
Model Code Example: CBBGLJNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 63 of 207
MODELCBDG
4.5:1 pilot ratio, restrictive counterbalance valveSERIES 2 / CAPACITY: 30 L/min. / CAVITY: T-2A
3-Port Non-vented
3-Port Non-vented, Fixed SettingCounterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 4.5:1Maximum Recommended Load Pressure at Maximum Setting 270 barMaximum Setting 350 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990202007Seal kit - Cartridge Polyurethane: 990002002Seal kit - Cartridge Viton: 990202006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
(J)FUNCTIONAL SETTING RANGEJ 2000 - 5000 psi w/25 psi Check (140 -
350 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard Setting
C 2000 - 5000 psi w/4 psi Check (140 -350 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
D 1000 - 2500 psi w/4 psi Check (70 -175 bar w/ 0,3 bar Check), 2000 psi(140 bar) Standard Setting
snhy.com/CBDG
Model Code Example: CBDGLJNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 64 of 207
(140 bar) Standard SettingK 1000 - 2500 psi w/25 psi Check (70 -
175 bar w/ 1,7 bar Check), 2000 psi(140 bar) Standard Setting
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 65 of 207
MODELCBFG
4.5:1 pilot ratio, restrictive counterbalance valveSERIES 3 / CAPACITY: 60 L/min. / CAVITY: T-17A
3-Port Non-vented
3-Port Non-vented, Fixed Setting
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 4.5:1Maximum Recommended Load Pressure at Maximum Setting 270 barMaximum Setting 350 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990017007Seal kit - Cartridge Polyurethane: 990017002Seal kit - Cartridge Viton: 990017006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/LH Mild Steel, Zinc-Nickel
(J)FUNCTIONAL SETTING RANGEJ 2000 - 5000 psi w/25 psi Check (140 -
350 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard SettingC 2000 - 5000 psi w/4 psi Check (140 -350 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
D 1000 - 2500 psi w/4 psi Check (70 -175 bar w/ 0,3 bar Check), 2000 psi(140 bar) Standard Setting
K 1000 - 2500 psi w/25 psi Check (70 -175 bar w/ 1,7 bar Check), 2000 psi
snhy.com/CBFG
Model Code Example: CBFGLJNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 66 of 207
175 bar w/ 1,7 bar Check), 2000 psi(140 bar) Standard Setting
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 67 of 207
MODELCBHG
4.5:1 pilot ratio, restrictive counterbalance valveSERIES 4 / CAPACITY: 80 L/min. / CAVITY: T-19A
3-Port Non-vented
3-Port Non-vented, Fixed Setting
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 4.5:1Maximum Recommended Load Pressure at Maximum Setting 270 barMaximum Setting 350 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 19,1 mmLocknut Torque 35 - 40 NmSeal kit - Cartridge Buna: 990019007Seal kit - Cartridge Polyurethane: 990019002Seal kit - Cartridge Viton: 990019006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(N)SEAL MATERIALN Buna-NV Viton
(J)FUNCTIONAL SETTING RANGEJ 2000 - 5000 psi w/25 psi Check (140 -
350 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard Setting
C 2000 - 5000 psi w/4 psi Check (140 -350 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
D 1000 - 2500 psi w/4 psi Check (70 -175 bar w/ 0,3 bar Check), 2000 psi(140 bar) Standard Setting
K 1000 - 2500 psi w/25 psi Check (70 -175 bar w/ 1,7 bar Check), 2000 psi(140 bar) Standard Setting
snhy.com/CBHG
Model Code Example: CBHGLJNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 68 of 207
(140 bar) Standard Setting
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 69 of 207
MODELCBAB
1.5:1 pilot ratio, ultra-restrictive counterbalance valveSERIES 1 / CAPACITY: 10 L/min. / CAVITY: T-11A
3-Port Non-vented Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 1.5:1Maximum Recommended Load Pressure at Maximum Setting 215 barMaximum Setting 280 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990011007Seal kit - Cartridge Polyurethane: 990011002Seal kit - Cartridge Viton: 990011006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory SetR Lockwired Screw Adjustment
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi w/25 psi Check (70 -
280 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard Setting
A 1000 - 4000 psi w/4 psi Check (70 -280 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
B 400 - 1500 psi w/4 psi Check (28 - 105bar w/ 0,3 bar Check), 1000 psi (70bar) Standard Setting
I 400 - 1500 psi w/25 psi Check (28 -105 bar w/ 1,7 bar Check), 1000 psi (70bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/CBAB
Model Code Example: CBABLHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 70 of 207
MODELCBAA
3:1 pilot ratio, ultra-restrictive counterbalance valveSERIES 1 / CAPACITY: 10 L/min. / CAVITY: T-11A
3-Port Non-vented Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 3:1Maximum Recommended Load Pressure at Maximum Setting 215 barMaximum Setting 280 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990011007Seal kit - Cartridge Polyurethane: 990011002Seal kit - Cartridge Viton: 990011006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory SetR Lockwired Screw Adjustment
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi w/25 psi Check (70 -
280 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard Setting
A 1000 - 4000 psi w/4 psi Check (70 -280 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
B 400 - 1500 psi w/4 psi Check (28 - 105bar w/ 0,3 bar Check), 1000 psi (70bar) Standard Setting
I 400 - 1500 psi w/25 psi Check (28 -105 bar w/ 1,7 bar Check), 1000 psi (70bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/CBAA
Model Code Example: CBAALHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 71 of 207
MODELCBAG
4.5:1 pilot ratio, ultra-restrictive counterbalance valveSERIES 1 / CAPACITY: 10 L/min. / CAVITY: T-11A
3-Port Non-vented Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 4.5:1Maximum Recommended Load Pressure at Maximum Setting 270 barMaximum Setting 350 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990011007Seal kit - Cartridge Polyurethane: 990011002Seal kit - Cartridge Viton: 990011006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory SetR Lockwired Screw Adjustment
(J)FUNCTIONAL SETTING RANGEJ 2000 - 5000 psi w/25 psi Check (140 -
350 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard Setting
C 2000 - 5000 psi w/4 psi Check (140 -350 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
D 1000 - 2500 psi w/4 psi Check (70 -175 bar w/ 0,3 bar Check), 2000 psi(140 bar) Standard Setting
K 1000 - 2500 psi w/25 psi Check (70 -175 bar w/ 1,7 bar Check), 2000 psi(140 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/LH Mild Steel, Zinc-Nickel
snhy.com/CBAG
Model Code Example: CBAGLJNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 72 of 207
MODELCBAH
10:1 pilot ratio, ultra-restrictive counterbalance valveSERIES 1 / CAPACITY: 10 L/min. / CAVITY: T-11A
3-Port Non-vented
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 10:1Maximum Recommended Load Pressure at Maximum Setting 270 barMaximum Setting 350 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990011007Seal kit - Cartridge Polyurethane: 990011002Seal kit - Cartridge Viton: 990011006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(J)FUNCTIONAL SETTING RANGEJ 2000 - 5000 psi w/25 psi Check (140 -
350 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard Setting
C 2000 - 5000 psi w/4 psi Check (140 -350 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
D 1000 - 2500 psi w/4 psi Check (70 -175 bar w/ 0,3 bar Check), 2000 psi(140 bar) Standard Setting
K 1000 - 2500 psi w/25 psi Check (70 -175 bar w/ 1,7 bar Check), 2000 psi(140 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/CBAH
Model Code Example: CBAHLJNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 73 of 207
MODELCBCLX
Fixed setting, 2.3:1 pilot ratio, standard capacity counterbalance valveSERIES 1 / CAPACITY: 60 L/min. / CAVITY: T-11A
3-Port Non-vented, Fixed Setting
Fixed-setting, 3-port counterbalance valves with pilot assist function similarly to the adjustable versions except thefixed setting is pre-set to a nominal value. These fixed-setting valves are meant to control an overrunning load. Thecheck valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the reliefvalve at a rate determined by the pilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 2.3:1Factory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barSeal kit - Cartridge Buna: 990011007Seal kit - Cartridge Polyurethane: 990011002Seal kit - Cartridge Viton: 990011006
(M)FIXED PRESSURE RANGEM 4700 - 5600 psi (325 - 390 bar)V 3200 - 3800 psi (220 - 260 bar)X 3500 - 4200 psi (245 - 290 bar)Z 4125 - 4900 psi (285 - 340 bar)
(N)SEAL MATERIALN Buna-NE EPDMV Viton
MATERIAL/COATINGStandard Material/Coating
/LH Mild Steel, Zinc-Nickel
snhy.com/CBCLX
Model Code Example: CBCLXMNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 74 of 207
MODELCBCAX
Fixed setting, 3:1 pilot ratio, standard capacity counterbalance valveSERIES 1 / CAPACITY: 60 L/min. / CAVITY: T-11A
3-Port Non-vented, Fixed Setting
Fixed-setting, 3-port counterbalance valves with pilot assist function similarly to the adjustable versions except thefixed setting is pre-set to a nominal value. These fixed-setting valves are meant to control an overrunning load. Thecheck valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the reliefvalve at a rate determined by the pilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 3:1Factory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barSeal kit - Cartridge Buna: 990011007Seal kit - Cartridge EPDM: 990011014Seal kit - Cartridge Polyurethane: 990011002Seal kit - Cartridge Viton: 990011006
(N)FIXED PRESSURE RANGEN 2900 - 3500 psi (200 - 245 bar)P 2250 - 2680 psi (155 - 185 bar)
(N)SEAL MATERIALN Buna-NE EPDMV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/CBCAX
Model Code Example: CBCAXNNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 75 of 207
MODELCBEAX
Fixed setting, 3:1 pilot ratio, standard capacity counterbalance valveSERIES 2 / CAPACITY: 120 L/min. / CAVITY: T-2A
3-Port Non-vented, Fixed Setting
Fixed-setting, 3-port counterbalance valves with pilot assist function similarly to the adjustable versions except thefixed setting is pre-set to a nominal value. These fixed-setting valves are meant to control an overrunning load. Thecheck valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the reliefvalve at a rate determined by the pilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 3:1Factory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Reseat >85% of settingSeal kit - Cartridge Buna: 990202007Seal kit - Cartridge Polyurethane: 990002002Seal kit - Cartridge Viton: 990202006
(N)FIXED PRESSURE RANGEN 2900 - 3500 psi (200 - 245 bar)P 2250 - 2680 psi (155 - 185 bar)
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/LH Mild Steel, Zinc-Nickel
snhy.com/CBEAX
Model Code Example: CBEAXNNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 76 of 207
MODELCBCGX
Fixed setting, 4.5:1 pilot ratio, standard capacity counterbalance valveSERIES 1 / CAPACITY: 60 L/min. / CAVITY: T-11A
3-Port Non-vented, Fixed Setting
Fixed-setting, 3-port counterbalance valves with pilot assist function similarly to the adjustable versions except thefixed setting is pre-set to a nominal value. These fixed-setting valves are meant to control an overrunning load. Thecheck valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the reliefvalve at a rate determined by the pilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 4.5:1Factory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barSeal kit - Cartridge Buna: 990011007Seal kit - Cartridge Polyurethane: 990011002Seal kit - Cartridge Viton: 990011006
(M)FIXED PRESSURE RANGEM 4700 - 5600 psi (325 - 390 bar)V 3200 - 3800 psi (220 - 260 bar)X 3500 - 4200 psi (245 - 290 bar)Z 4125 - 4900 psi (285 - 340 bar)
(N)SEAL MATERIALN Buna-NE EPDMV Viton
MATERIAL/COATINGStandard Material/Coating
/LH Mild Steel, Zinc-Nickel
snhy.com/CBCGX
Model Code Example: CBCGXMNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 77 of 207
MODELCBCHX
Fixed setting, 10:1 pilot ratio, standard capacity counterbalance valveSERIES 1 / CAPACITY: 60 L/min. / CAVITY: T-11A
3-Port Non-vented, Fixed Setting
Fixed-setting, 3-port counterbalance valves with pilot assist function similarly to the adjustable versions except thefixed setting is pre-set to a nominal value. These fixed-setting valves are meant to control an overrunning load. Thecheck valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the reliefvalve at a rate determined by the pilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 10:1Factory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barSeal kit - Cartridge Buna: 990011007Seal kit - Cartridge Polyurethane: 990011002Seal kit - Cartridge Viton: 990011006
(M)FIXED PRESSURE RANGEM 4700 - 5600 psi (325 - 390 bar)V 3200 - 3800 psi (220 - 260 bar)X 3500 - 4200 psi (245 - 290 bar)Z 4125 - 4900 psi (285 - 340 bar)
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/CBCHX
Model Code Example: CBCHXMNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 78 of 207
MODELCBBLX
Fixed setting, 2.3:1 pilot ratio, semi-restrictive counterbalance valveSERIES 1 / CAPACITY: 40 L/min. / CAVITY: T-11A
3-Port Non-vented, Fixed Setting
Fixed-setting, 3-port counterbalance valves with pilot assist function similarly to the adjustable versions except thefixed setting is pre-set to a nominal value. These fixed-setting valves are meant to control an overrunning load. Thecheck valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the reliefvalve at a rate determined by the pilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 2.3:1Factory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barSeal kit - Cartridge Buna: 990011007Seal kit - Cartridge Polyurethane: 990011002Seal kit - Cartridge Viton: 990011006
(M)FIXED PRESSURE RANGEM 4700 - 5600 psi (325 - 390 bar)V 3200 - 3800 psi (220 - 260 bar)X 3500 - 4200 psi (245 - 290 bar)Z 4125 - 4900 psi (285 - 340 bar)
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/LH Mild Steel, Zinc-Nickel
snhy.com/CBBLX
Model Code Example: CBBLXMNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 79 of 207
MODELCBBCX
Fixed setting, 3:1 pilot ratio, semi-restrictive counterbalance valveSERIES 1 / CAPACITY: 40 L/min. / CAVITY: T-11A
3-Port Non-vented, Fixed Setting
Fixed-setting, 3-port counterbalance valves with pilot assist function similarly to the adjustable versions except thefixed setting is pre-set to a nominal value. These fixed-setting valves are meant to control an overrunning load. Thecheck valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the reliefvalve at a rate determined by the pilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 3:1Factory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barSeal kit - Cartridge Buna: 990011007Seal kit - Cartridge Polyurethane: 990011002Seal kit - Cartridge Viton: 990011006
(N)FIXED PRESSURE RANGEN 2900 - 3500 psi (200 - 245 bar)P 2250 - 2680 psi (155 - 185 bar)
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/LH Mild Steel, Zinc-Nickel
snhy.com/CBBCX
Model Code Example: CBBCXNNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 80 of 207
MODELCBDCX
Fixed setting, 3:1 pilot ratio, semi-restrictive counterbalance valveSERIES 2 / CAPACITY: 80 L/min. / CAVITY: T-2A
3-Port Non-vented, Fixed SettingCounterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 3:1Maximum Recommended Load Pressure at Maximum Setting 215 barMaximum Setting 280 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Reseat >85% of settingSeal kit - Cartridge Buna: 990202007Seal kit - Cartridge Polyurethane: 990002002Seal kit - Cartridge Viton: 990202006
(N)FIXED PRESSURE RANGEN 2900 - 3500 psi (200 - 245 bar)P 2250 - 2680 psi (155 - 185 bar)
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/LH Mild Steel, Zinc-Nickel
snhy.com/CBDCX
Model Code Example: CBDCXNNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 81 of 207
MODELCBBDX
Fixed setting, 4.5:1 pilot ratio, semi-restrictive counterbalance valveSERIES 1 / CAPACITY: 40 L/min. / CAVITY: T-11A
3-Port Non-vented, Fixed Setting
Fixed-setting, 3-port counterbalance valves with pilot assist function similarly to the adjustable versions except thefixed setting is pre-set to a nominal value. These fixed-setting valves are meant to control an overrunning load. Thecheck valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the reliefvalve at a rate determined by the pilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 4.5:1Factory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barSeal kit - Cartridge Buna: 990011007Seal kit - Cartridge EPDM: 990011014Seal kit - Cartridge Polyurethane: 990011002Seal kit - Cartridge Viton: 990011006
(X)FIXED PRESSURE RANGEX 3500 - 4200 psi (245 - 290 bar)M 4700 - 5600 psi (325 - 390 bar)V 3200 - 3800 psi (220 - 260 bar)Z 4125 - 4900 psi (285 - 340 bar)
(N)SEAL MATERIALN Buna-NE EPDMV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated
snhy.com/CBBDX
Model Code Example: CBBDXXNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 82 of 207
MODELCBDDX
Fixed setting, 4.5:1 pilot ratio, semi-restrictive counterbalance valveSERIES 2 / CAPACITY: 80 L/min. / CAVITY: T-2A
3-Port Non-vented, Fixed SettingFixed-setting, 3-port counterbalance valves with pilot assist function similarly to the adjustable versions except thefixed setting is pre-set to a nominal value. These fixed-setting valves are meant to control an overrunning load. Thecheck valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the reliefvalve at a rate determined by the pilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 4.5:1Factory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Reseat >85% of settingSeal kit - Cartridge Buna: 990202007Seal kit - Cartridge Polyurethane: 990002002Seal kit - Cartridge Viton: 990202006
(X)FIXED PRESSURE RANGEX 3500 - 4200 psi (245 - 290 bar)M 4700 - 5600 psi (325 - 390 bar)V 3200 - 3800 psi (220 - 260 bar)Z 4125 - 4900 psi (285 - 340 bar)
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/LH Mild Steel, Zinc-Nickel
snhy.com/CBDDX
Model Code Example: CBDDXXNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 83 of 207
MODELCBBAX
Fixed setting, 3:1 pilot ratio, restrictive counterbalance valveSERIES 1 / CAPACITY: 20 L/min. / CAVITY: T-11A
3-Port Non-vented, Fixed Setting
Fixed-setting, 3-port counterbalance valves with pilot assist function similarly to the adjustable versions except thefixed setting is pre-set to a nominal value. These fixed-setting valves are meant to control an overrunning load. Thecheck valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the reliefvalve at a rate determined by the pilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 3:1Factory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barSeal kit - Cartridge Buna: 990011007Seal kit - Cartridge Polyurethane: 990011002Seal kit - Cartridge Viton: 990011006
(N)FIXED PRESSURE RANGEN 2900 - 3500 psi (200 - 245 bar)P 2250 - 2680 psi (155 - 185 bar)
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/CBBAX
Model Code Example: CBBAXNNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 84 of 207
MODELCBDAX
Fixed setting, 3:1 pilot ratio, restrictive counterbalance valveSERIES 2 / CAPACITY: 30 L/min. / CAVITY: T-2A
3-Port Non-vented, Fixed SettingFixed-setting, 3-port counterbalance valves with pilot assist function similarly to the adjustable versions except thefixed setting is pre-set to a nominal value. These fixed-setting valves are meant to control an overrunning load. Thecheck valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the reliefvalve at a rate determined by the pilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 3:1Maximum Recommended Load Pressure at Maximum Setting 215 barMaximum Setting 280 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Reseat >85% of settingSeal kit - Cartridge Buna: 990202007Seal kit - Cartridge Polyurethane: 990002002Seal kit - Cartridge Viton: 990202006
(N)FIXED PRESSURE RANGEN 2900 - 3500 psi (200 - 245 bar)P 2250 - 2680 psi (155 - 185 bar)
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/LH Mild Steel, Zinc-Nickel
snhy.com/CBDAX
Model Code Example: CBDAXNNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 85 of 207
MODELCBBGX
Fixed setting, 4.5:1 pilot ratio, restrictive counterbalance valveSERIES 1 / CAPACITY: 20 L/min. / CAVITY: T-11A
3-Port Non-vented, Fixed Setting
Fixed-setting, 3-port counterbalance valves with pilot assist function similarly to the adjustable versions except thefixed setting is pre-set to a nominal value. These fixed-setting valves are meant to control an overrunning load. Thecheck valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the reliefvalve at a rate determined by the pilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 4.5:1Factory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barSeal kit - Cartridge Buna: 990011007Seal kit - Cartridge Polyurethane: 990011002Seal kit - Cartridge Viton: 990011006
(M)FIXED PRESSURE RANGEM 4700 - 5600 psi (325 - 390 bar)V 3200 - 3800 psi (220 - 260 bar)X 3500 - 4200 psi (245 - 290 bar)Z 4125 - 4900 psi (285 - 340 bar)
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/LH Mild Steel, Zinc-Nickel
snhy.com/CBBGX
Model Code Example: CBBGXMNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 86 of 207
MODELCBDGX
Fixed setting, 4.5:1 pilot ratio, restrictive counterbalance valveSERIES 2 / CAVITY: T-2A
3-Port Non-vented, Fixed SettingFixed-setting, 3-port counterbalance valves with pilot assist function similarly to the adjustable versions except thefixed setting is pre-set to a nominal value. These fixed-setting valves are meant to control an overrunning load. Thecheck valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the reliefvalve at a rate determined by the pilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 4.5:1Maximum Recommended Load Pressure at Maximum Setting 270 barMaximum Setting 350 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Reseat >85% of settingSeal kit - Cartridge Buna: 990202007Seal kit - Cartridge Polyurethane: 990002002Seal kit - Cartridge Viton: 990202006
(X)FIXED PRESSURE RANGEX 3500 - 4200 psi (245 - 290 bar)M 4700 - 5600 psi (325 - 390 bar)V 3200 - 3800 psi (220 - 260 bar)Z 4125 - 4900 psi (285 - 340 bar)
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/LH Mild Steel, Zinc-Nickel
snhy.com/CBDGX
Model Code Example: CBDGXXNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 87 of 207
MODELCBABX
Fixed setting, 1.5:1 pilot ratio, ultra-restrictive counterbalance valveSERIES 1 / CAPACITY: 10 L/min. / CAVITY: T-11A
3-Port Non-vented, Fixed SettingFixed-setting, 3-port counterbalance valves with pilot assist function similarly to the adjustable versions except thefixed setting is pre-set to a nominal value. These fixed-setting valves are meant to control an overrunning load. Thecheck valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the reliefvalve at a rate determined by the pilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 1.5:1Factory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barSeal kit - Cartridge Buna: 990011007Seal kit - Cartridge Polyurethane: 990011002Seal kit - Cartridge Viton: 990011006
(N)FIXED PRESSURE RANGEN 2900 - 3500 psi (200 - 245 bar)P 2250 - 2680 psi (155 - 185 bar)
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/LH Mild Steel, Zinc-Nickel
snhy.com/CBABX
Model Code Example: CBABXNNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 88 of 207
MODELCBAAX
Fixed setting, 3:1 pilot ratio, ultra-restrictive counterbalance valveSERIES 1 / CAPACITY: 10 L/min. / CAVITY: T-11A
3-Port Non-vented, Fixed SettingFixed-setting, 3-port counterbalance valves with pilot assist function similarly to the adjustable versions except thefixed setting is pre-set to a nominal value. These fixed-setting valves are meant to control an overrunning load. Thecheck valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the reliefvalve at a rate determined by the pilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 3:1Factory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barSeal kit - Cartridge Buna: 990011007Seal kit - Cartridge Polyurethane: 990011002Seal kit - Cartridge Viton: 990011006
(N)FIXED PRESSURE RANGEN 2900 - 3500 psi (200 - 245 bar)P 2250 - 2680 psi (155 - 185 bar)
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/LH Mild Steel, Zinc-Nickel
snhy.com/CBAAX
Model Code Example: CBAAXNNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 89 of 207
MODELCBAGX
Fixed setting, 4.5:1 pilot ratio, ultra-restrictive counterbalance valveSERIES 1 / CAPACITY: 10 L/min. / CAVITY: T-11A
3-Port Non-vented, Fixed SettingFixed-setting, 3-port counterbalance valves with pilot assist function similarly to the adjustable versions except thefixed setting is pre-set to a nominal value. These fixed-setting valves are meant to control an overrunning load. Thecheck valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the reliefvalve at a rate determined by the pilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 4.5:1Factory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barSeal kit - Cartridge Buna: 990011007Seal kit - Cartridge Polyurethane: 990011002Seal kit - Cartridge Viton: 990011006
(M)FIXED PRESSURE RANGEM 4700 - 5600 psi (325 - 390 bar)V 3200 - 3800 psi (220 - 260 bar)X 3500 - 4200 psi (245 - 290 bar)Z 4125 - 4900 psi (285 - 340 bar)
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/LH Mild Steel, Zinc-Nickel
snhy.com/CBAGX
Model Code Example: CBAGXMNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 90 of 207
MODELCABK
1:1 pilot ratio, vented counterbalance valve - atmospherically referencedSERIES 1 / CAPACITY: 30 L/min. / CAVITY: T-11A
3-Port Atmospherically Referenced
3-Port Atmospherically Referenced, Non-adjustable
Atmospherically-vented counterbalance valves with pilot assist are meant to control an overrunning load. The checkvalve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted reliefvalve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a ratedetermined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because the spring chamberis atmospherically referenced.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 1:1Maximum Recommended Load Pressure at Maximum Setting 215 barMaximum Setting 280 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 2,8 barAdjustment - Number of Counterclockwise Turns to Increase Setting 3Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990011007Seal kit - Cartridge Polyurethane: 990011002Seal kit - Cartridge Viton: 990011006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi w/25 psi Check (70 -
280 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/CABK
Model Code Example: CABKLHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 91 of 207
MODELCACK
1:1 pilot ratio, vented counterbalance valve - atmospherically referencedSERIES 1 / CAPACITY: 60 L/min. / CAVITY: T-11A
3-Port Atmospherically Referenced
3-Port Atmospherically Referenced, Non-adjustable
Atmospherically-vented counterbalance valves with pilot assist are meant to control an overrunning load. The checkvalve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted reliefvalve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a ratedetermined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because the spring chamberis atmospherically referenced.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 1:1Maximum Recommended Load Pressure at Maximum Setting 215 barMaximum Setting 280 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 2,8 barAdjustment - Number of Counterclockwise Turns to Increase Setting 5Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990211007Seal kit - Cartridge Viton: 990211006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi (70 - 280 bar), 3000 psi
(210 bar) Standard SettingI 400 - 1500 psi (28 - 105 bar), 1000 psi
(70 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/LH Mild Steel, Zinc-Nickel
snhy.com/CACK
Model Code Example: CACKLHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 92 of 207
MODELCAEK
1:1 pilot ratio, vented counterbalance valve - atmospherically referencedSERIES 2 / CAPACITY: 120 L/min. / CAVITY: T-2A
3-Port Atmospherically Referenced
3-Port Atmospherically Referenced, Non-adjustable
Atmospherically-vented counterbalance valves with pilot assist are meant to control an overrunning load. The checkvalve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted reliefvalve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a ratedetermined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because the spring chamberis atmospherically referenced.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 1:1Maximum Recommended Load Pressure at Maximum Setting 215 barMaximum Setting 280 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barAdjustment - Number of Counterclockwise Turns to Increase Setting 5Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990302007Seal kit - Cartridge Viton: 990302006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi (70 - 280 bar), 3000 psi
(210 bar) Standard SettingI 400 - 1500 psi (28 - 105 bar), 1000 psi
(70 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/CAEK
Model Code Example: CAEKLHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 93 of 207
MODELCAGK
1:1 pilot ratio, vented counterbalance valve - atmospherically referencedSERIES 3 / CAPACITY: 240 L/min. / CAVITY: T-17A
3-Port Atmospherically Referenced
3-Port Atmospherically Referenced, Non-adjustable
Atmospherically-vented counterbalance valves with pilot assist are meant to control an overrunning load. The checkvalve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted reliefvalve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a ratedetermined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because the spring chamberis atmospherically referenced.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 1:1Maximum Recommended Load Pressure at Maximum Setting 215 barMaximum Setting 280 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barAdjustment - Number of Counterclockwise Turns to Increase Setting 5Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990117007Seal kit - Cartridge Viton: 990117006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi (70 - 280 bar), 3000 psi
(210 bar) Standard Setting
I 400 - 1500 psi (28 - 105 bar), 1000 psi(70 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/CAGK
Model Code Example: CAGKLHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 94 of 207
MODELCAIK
1:1 pilot ratio, vented counterbalance valve - atmospherically referencedSERIES 4 / CAPACITY: 480 L/min. / CAVITY: T-19A
3-Port Atmospherically Referenced
3-Port Atmospherically Referenced, Non-adjustable
Atmospherically-vented counterbalance valves with pilot assist are meant to control an overrunning load. The checkvalve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted reliefvalve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a ratedetermined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because the spring chamberis atmospherically referenced.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 1:1Maximum Recommended Load Pressure at Maximum Setting 215 barMaximum Setting 280 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,5 barAdjustment - Number of Counterclockwise Turns to Increase Setting 5Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990119007Seal kit - Cartridge Polyurethane: 990119002Seal kit - Cartridge Viton: 990119006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi (70 - 280 bar), 3000 psi
(210 bar) Standard SettingI 400 - 1500 psi (28 - 105 bar), 1000 psi
(70 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/CAIK
Model Code Example: CAIKLHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 95 of 207
MODELCACL
2:1 pilot ratio, vented counterbalance valve - atmospherically referencedSERIES 1 / CAPACITY: 60 L/min. / CAVITY: T-11A
3-Port Atmospherically Referenced
3-Port Atmospherically Referenced, Non-adjustable
Atmospherically-vented counterbalance valves with pilot assist are meant to control an overrunning load. The checkvalve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted reliefvalve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a ratedetermined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because the spring chamberis atmospherically referenced.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 2:1Maximum Recommended Load Pressure at Maximum Setting 320 barMaximum Setting 420 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 2,8 barAdjustment - Number of Counterclockwise Turns to Increase Setting 5Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990211007Seal kit - Cartridge Viton: 990211006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(F)FUNCTIONAL SETTING RANGEF 1000 - 2500 psi (70 - 175 bar), 2000 psi
(140 bar) Standard SettingG 2000 - 6000 psi (140 - 420 bar), 4000
psi (280 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/LH Mild Steel, Zinc-Nickel
snhy.com/CACL
Model Code Example: CACLLFNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 96 of 207
MODELCAEL
2:1 pilot ratio, vented counterbalance valve - atmospherically referencedSERIES 2 / CAPACITY: 120 L/min. / CAVITY: T-2A
3-Port Atmospherically Referenced
3-Port Atmospherically Referenced, Non-adjustable
Atmospherically-vented counterbalance valves with pilot assist are meant to control an overrunning load. The checkvalve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted reliefvalve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a ratedetermined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because the spring chamberis atmospherically referenced.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 2:1Maximum Recommended Load Pressure at Maximum Setting 320 barMaximum Setting 420 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barAdjustment - Number of Counterclockwise Turns to Increase Setting 5Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990302007Seal kit - Cartridge Viton: 990302006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(G)FUNCTIONAL SETTING RANGEG 2000 - 6000 psi (140 - 420 bar), 4000
psi (280 bar) Standard SettingF 1000 - 2500 psi (70 - 175 bar), 2000 psi
(140 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/CAEL
Model Code Example: CAELLGNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 97 of 207
MODELCAGL
2:1 pilot ratio, vented counterbalance valve - atmospherically referencedSERIES 3 / CAPACITY: 240 L/min. / CAVITY: T-17A
3-Port Atmospherically Referenced
3-Port Atmospherically Referenced, Non-adjustable
Atmospherically-vented counterbalance valves with pilot assist are meant to control an overrunning load. The checkvalve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted reliefvalve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a ratedetermined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because the spring chamberis atmospherically referenced.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 2:1Maximum Recommended Load Pressure at Maximum Setting 320 barMaximum Setting 420 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barAdjustment - Number of Counterclockwise Turns to Increase Setting 5Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990117007Seal kit - Cartridge Viton: 990117006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(G)FUNCTIONAL SETTING RANGEG 2000 - 6000 psi (140 - 420 bar), 4000
psi (280 bar) Standard SettingF 1000 - 2500 psi (70 - 175 bar), 2000 psi
(140 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated
snhy.com/CAGL
Model Code Example: CAGLLGNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 98 of 207
MODELCAIL
2:1 pilot ratio, vented counterbalance valve - atmospherically referencedSERIES 4 / CAPACITY: 480 L/min. / CAVITY: T-19A
3-Port Atmospherically Referenced
3-Port Atmospherically Referenced, Non-adjustable
Atmospherically-vented counterbalance valves with pilot assist are meant to control an overrunning load. The checkvalve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted reliefvalve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a ratedetermined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because the spring chamberis atmospherically referenced.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 2:1Maximum Recommended Load Pressure at Maximum Setting 320 barMaximum Setting 420 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,5 barAdjustment - Number of Counterclockwise Turns to Increase Setting 5Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990119007Seal kit - Cartridge Polyurethane: 990119002Seal kit - Cartridge Viton: 990119006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(G)FUNCTIONAL SETTING RANGEG 2000 - 6000 psi (140 - 420 bar), 4000
psi (280 bar) Standard SettingF 1000 - 2500 psi (70 - 175 bar), 2000 psi
(140 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/LH Mild Steel, Zinc-Nickel
snhy.com/CAIL
Model Code Example: CAILLGNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 99 of 207
MODELCACA
3:1 pilot ratio, vented counterbalance valve - atmospherically referencedSERIES 1 / CAVITY: T-11A
3-Port Atmospherically Referenced
3-Port Atmospherically Referenced, Non-adjustable
Atmospherically-vented counterbalance valves with pilot assist are meant to control an overrunning load. The checkvalve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted reliefvalve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a ratedetermined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because the spring chamberis atmospherically referenced.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 3:1Maximum Recommended Load Pressure at Maximum Setting 215 barMaximum Setting 280 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 2,8 barAdjustment - Number of Counterclockwise Turns to Increase Setting 5Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990211007Seal kit - Cartridge Viton: 990211006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi (70 - 280 bar), 3000 psi
(210 bar) Standard SettingI 400 - 1500 psi (28 - 105 bar), 1000 psi
(70 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/CACA
Model Code Example: CACALHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 100 of 207
MODELCAEA
3:1 pilot ratio, vented counterbalance valve - atmospherically referencedSERIES 2 / CAPACITY: 120 L/min. / CAVITY: T-2A
3-Port Atmospherically Referenced
3-Port Atmospherically Referenced, Non-adjustable
Atmospherically-vented counterbalance valves with pilot assist are meant to control an overrunning load. The checkvalve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted reliefvalve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a ratedetermined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because the spring chamberis atmospherically referenced.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 3:1Maximum Recommended Load Pressure at Maximum Setting 215 barMaximum Setting 280 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barAdjustment - Number of Counterclockwise Turns to Increase Setting 5Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990302007Seal kit - Cartridge Viton: 990302006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi (70 - 280 bar), 3000 psi
(210 bar) Standard SettingI 400 - 1500 psi (28 - 105 bar), 1000 psi
(70 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/LH Mild Steel, Zinc-Nickel
snhy.com/CAEA
Model Code Example: CAEALHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 101 of 207
MODELCAGA
3:1 pilot ratio, vented counterbalance valve - atmospherically referencedSERIES 3 / CAPACITY: 240 L/min. / CAVITY: T-17A
3-Port Atmospherically Referenced
3-Port Atmospherically Referenced, Non-adjustable
Atmospherically-vented counterbalance valves with pilot assist are meant to control an overrunning load. The checkvalve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted reliefvalve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a ratedetermined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because the spring chamberis atmospherically referenced.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 3:1Maximum Recommended Load Pressure at Maximum Setting 215 barMaximum Setting 280 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barAdjustment - Number of Counterclockwise Turns to Increase Setting 5Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990117007Seal kit - Cartridge Viton: 990117006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi (70 - 280 bar), 3000 psi
(210 bar) Standard SettingI 400 - 1500 psi (28 - 105 bar), 1000 psi
(70 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/CAGA
Model Code Example: CAGALHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 102 of 207
MODELCAIA
3:1 pilot ratio, vented counterbalance valve - atmospherically referencedSERIES 4 / CAPACITY: 480 L/min. / CAVITY: T-19A
3-Port Atmospherically Referenced
3-Port Atmospherically Referenced, Non-adjustable
Atmospherically-vented counterbalance valves with pilot assist are meant to control an overrunning load. The checkvalve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted reliefvalve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a ratedetermined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because the spring chamberis atmospherically referenced.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 3:1Maximum Recommended Load Pressure at Maximum Setting 215 barMaximum Setting 280 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,5 barAdjustment - Number of Counterclockwise Turns to Increase Setting 5Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990119007Seal kit - Cartridge Polyurethane: 990119002Seal kit - Cartridge Viton: 990119006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi (70 - 280 bar), 3000 psi
(210 bar) Standard SettingI 400 - 1500 psi (28 - 105 bar), 1000 psi
(70 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/CAIA
Model Code Example: CAIALHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 103 of 207
MODELCABG
4.5:1 pilot ratio, vented counterbalance valve - atmospherically referencedSERIES 1 / CAPACITY: 30 L/min. / CAVITY: T-11A
3-Port Atmospherically Referenced
3-Port Atmospherically Referenced, Non-adjustable
Atmospherically-vented counterbalance valves with pilot assist are meant to control an overrunning load. The checkvalve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted reliefvalve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a ratedetermined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because the spring chamberis atmospherically referenced.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 4.5:1Maximum Recommended Load Pressure at Maximum Setting 215 barMaximum Setting 280 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barAdjustment - Number of Counterclockwise Turns to Increase Setting 3Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990011007Seal kit - Cartridge Polyurethane: 990011002Seal kit - Cartridge Viton: 990011006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi w/25 psi Check (70 -
280 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/CABG
Model Code Example: CABGLHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 104 of 207
MODELCACG
5:1 pilot ratio, vented counterbalance valve - atmospherically referencedSERIES 1 / CAPACITY: 60 L/min. / CAVITY: T-11A
3-Port Atmospherically Referenced
3-Port Atmospherically Referenced, Non-adjustable
Atmospherically-vented counterbalance valves with pilot assist are meant to control an overrunning load. The checkvalve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted reliefvalve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a ratedetermined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because the spring chamberis atmospherically referenced.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 5:1Maximum Recommended Load Pressure at Maximum Setting 320 barMaximum Setting 420 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 2,8 barAdjustment - Number of Counterclockwise Turns to Increase Setting 5Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990211007Seal kit - Cartridge Viton: 990211006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(G)FUNCTIONAL SETTING RANGEG 2000 - 6000 psi (140 - 420 bar), 4000
psi (280 bar) Standard SettingF 1000 - 2500 psi (70 - 175 bar), 2000 psi
(140 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/CACG
Model Code Example: CACGLGNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 105 of 207
MODELCAEG
5:1 pilot ratio, vented counterbalance valve - atmospherically referencedSERIES 2 / CAPACITY: 120 L/min. / CAVITY: T-2A
3-Port Atmospherically Referenced
3-Port Atmospherically Referenced, Non-adjustable
Atmospherically-vented counterbalance valves with pilot assist are meant to control an overrunning load. The checkvalve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted reliefvalve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a ratedetermined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because the spring chamberis atmospherically referenced.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 5:1Maximum Recommended Load Pressure at Maximum Setting 320 barMaximum Setting 420 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barAdjustment - Number of Counterclockwise Turns to Increase Setting 5Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990302007Seal kit - Cartridge Viton: 990302006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(G)FUNCTIONAL SETTING RANGEG 2000 - 6000 psi (140 - 420 bar), 4000
psi (280 bar) Standard SettingF 1000 - 2500 psi (70 - 175 bar), 2000 psi
(140 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated
snhy.com/CAEG
Model Code Example: CAEGLGNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 106 of 207
MODELCAGG
5:1 pilot ratio, vented counterbalance valve - atmospherically referencedSERIES 3 / CAPACITY: 240 L/min. / CAVITY: T-17A
3-Port Atmospherically Referenced
3-Port Atmospherically Referenced, Non-adjustable
Atmospherically-vented counterbalance valves with pilot assist are meant to control an overrunning load. The checkvalve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted reliefvalve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a ratedetermined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because the spring chamberis atmospherically referenced.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 5:1Maximum Recommended Load Pressure at Maximum Setting 320 barMaximum Setting 420 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barAdjustment - Number of Counterclockwise Turns to Increase Setting 5Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990117007Seal kit - Cartridge Viton: 990117006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(G)FUNCTIONAL SETTING RANGEG 2000 - 6000 psi (140 - 420 bar), 4000
psi (280 bar) Standard SettingF 1000 - 2500 psi (70 - 175 bar), 2000 psi
(140 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/CAGG
Model Code Example: CAGGLGNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 107 of 207
MODELCAIG
5:1 pilot ratio, vented counterbalance valve - atmospherically referencedSERIES 4 / CAPACITY: 480 L/min. / CAVITY: T-19A
3-Port Atmospherically Referenced
3-Port Atmospherically Referenced, Non-adjustable
Atmospherically-vented counterbalance valves with pilot assist are meant to control an overrunning load. The checkvalve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted reliefvalve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a ratedetermined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because the spring chamberis atmospherically referenced.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 5:1Maximum Recommended Load Pressure at Maximum Setting 320 barMaximum Setting 420 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,5 barAdjustment - Number of Counterclockwise Turns to Increase Setting 5Reseat >85% of settingLocknut Hex Size 15 mmSeal kit - Cartridge Buna: 990119007Seal kit - Cartridge Polyurethane: 990119002Seal kit - Cartridge Viton: 990119006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(G)FUNCTIONAL SETTING RANGEG 2000 - 6000 psi (140 - 420 bar), 4000
psi (280 bar) Standard SettingF 1000 - 2500 psi (70 - 175 bar), 2000 psi
(140 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/CAIG
Model Code Example: CAIGLGNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 108 of 207
MODELCWCK
1:1 pilot ratio, vented counterbalance valveSERIES 1 / CAPACITY: 60 L/min. / CAVITY: T-21A
4-Port Vented
4-Port Vented, Non-adjustable
Vented counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allowsfree flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valvecontrols flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a ratedetermined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because the spring chamberreferences the vent (port 4).
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 1:1Maximum Recommended Load Pressure at Maximum Setting 215 barMaximum Setting 280 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 2,8 barAdjustment - Number of Counterclockwise Turns to Increase Setting 5Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990021007Seal kit - Cartridge Polyurethane: 990021002Seal kit - Cartridge Viton: 990021006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi (70 - 280 bar), 3000 psi
(210 bar) Standard SettingI 400 - 1500 psi (28 - 105 bar), 1000 psi(70 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated
snhy.com/CWCK
Model Code Example: CWCKLHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 109 of 207
MODELCWEK
1:1 pilot ratio, vented counterbalance valveSERIES 2 / CAPACITY: 120 L/min. / CAVITY: T-22A
4-Port Vented
4-Port Vented, Non-adjustable
Vented counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allowsfree flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valvecontrols flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a ratedetermined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because the spring chamberreferences the vent (port 4).
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 1:1Maximum Recommended Load Pressure at Maximum Setting 215 barMaximum Setting 280 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barAdjustment - Number of Counterclockwise Turns to Increase Setting 5Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990022007Seal kit - Cartridge Polyurethane: 990022002Seal kit - Cartridge Viton: 990022006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi (70 - 280 bar), 3000 psi
(210 bar) Standard SettingI 400 - 1500 psi (28 - 105 bar), 1000 psi
(70 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/LH Mild Steel, Zinc-Nickel
snhy.com/CWEK
Model Code Example: CWEKLHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 110 of 207
MODELCWGK
1:1 pilot ratio, vented counterbalance valveSERIES 3 / CAPACITY: 240 L/min. / CAVITY: T-23A
4-Port Vented
4-Port Vented, Non-adjustable
Vented counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allowsfree flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valvecontrols flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a ratedetermined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because the spring chamberreferences the vent (port 4).
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 1:1Maximum Recommended Load Pressure at Maximum Setting 215 barMaximum Setting 280 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barAdjustment - Number of Counterclockwise Turns to Increase Setting 5Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990023007Seal kit - Cartridge Polyurethane: 990023002Seal kit - Cartridge Viton: 990023006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi (70 - 280 bar), 3000 psi
(210 bar) Standard SettingI 400 - 1500 psi (28 - 105 bar), 1000 psi(70 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/CWGK
Model Code Example: CWGKLHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 111 of 207
MODELCWIK
1:1 pilot ratio, vented counterbalance valveSERIES 4 / CAPACITY: 480 L/min. / CAVITY: T-24A
4-Port Vented
4-Port Vented, Non-adjustable
Vented counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allowsfree flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valvecontrols flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a ratedetermined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because the spring chamberreferences the vent (port 4).
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 1:1Maximum Recommended Load Pressure at Maximum Setting 215 barMaximum Setting 280 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,5 barAdjustment - Number of Counterclockwise Turns to Increase Setting 5Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990024007Seal kit - Cartridge Polyurethane: 990024002Seal kit - Cartridge Viton: 990024006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi (70 - 280 bar), 3000 psi
(210 bar) Standard SettingI 400 - 1500 psi (28 - 105 bar), 1000 psi(70 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/LH Mild Steel, Zinc-Nickel
snhy.com/CWIK
Model Code Example: CWIKLHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 112 of 207
MODELCWCL
2:1 pilot ratio, vented counterbalance valveSERIES 1 / CAPACITY: 60 L/min. / CAVITY: T-21A
4-Port Vented
4-Port Vented, Non-adjustable
Vented counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allowsfree flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valvecontrols flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a ratedetermined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because the spring chamberreferences the vent (port 4).
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 2:1Maximum Recommended Load Pressure at Maximum Setting 320 barMaximum Setting 420 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 2,8 barAdjustment - Number of Counterclockwise Turns to Increase Setting 5Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990021007Seal kit - Cartridge Polyurethane: 990021002Seal kit - Cartridge Viton: 990021006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(G)FUNCTIONAL SETTING RANGEG 2000 - 6000 psi (140 - 420 bar), 4000
psi (280 bar) Standard SettingF 1000 - 2500 psi (70 - 175 bar), 2000 psi
(140 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated
snhy.com/CWCL
Model Code Example: CWCLLGNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 113 of 207
MODELCWEL
2:1 pilot ratio, vented counterbalance valveSERIES 2 / CAPACITY: 120 L/min. / CAVITY: T-22A
4-Port Vented
4-Port Vented, Non-adjustable
Vented counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allowsfree flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valvecontrols flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a ratedetermined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because the spring chamberreferences the vent (port 4).
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 2:1Maximum Recommended Load Pressure at Maximum Setting 320 barMaximum Setting 420 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barAdjustment - Number of Counterclockwise Turns to Increase Setting 5Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990022007Seal kit - Cartridge Polyurethane: 990022002Seal kit - Cartridge Viton: 990022006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(G)FUNCTIONAL SETTING RANGEG 2000 - 6000 psi (140 - 420 bar), 4000
psi (280 bar) Standard SettingF 1000 - 2500 psi (70 - 175 bar), 2000 psi
(140 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/CWEL
Model Code Example: CWELLGNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 114 of 207
MODELCWGL
2:1 pilot ratio, vented counterbalance valveSERIES 3 / CAPACITY: 240 L/min. / CAVITY: T-23A
4-Port Vented
4-Port Vented, Non-adjustable
Vented counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allowsfree flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valvecontrols flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a ratedetermined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because the spring chamberreferences the vent (port 4).
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 2:1Maximum Recommended Load Pressure at Maximum Setting 320 barMaximum Setting 420 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barAdjustment - Number of Counterclockwise Turns to Increase Setting 5Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990023007Seal kit - Cartridge Polyurethane: 990023002Seal kit - Cartridge Viton: 990023006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(G)FUNCTIONAL SETTING RANGEG 2000 - 6000 psi (140 - 420 bar), 4000
psi (280 bar) Standard SettingF 1000 - 2500 psi (70 - 175 bar), 2000 psi(140 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated
snhy.com/CWGL
Model Code Example: CWGLLGNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 115 of 207
MODELCWIL
2:1 pilot ratio, vented counterbalance valveSERIES 4 / CAPACITY: 480 L/min. / CAVITY: T-24A
4-Port Vented
4-Port Vented, Non-adjustable
Vented counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allowsfree flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valvecontrols flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a ratedetermined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because the spring chamberreferences the vent (port 4).
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 2:1Maximum Recommended Load Pressure at Maximum Setting 320 barMaximum Setting 420 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,5 barAdjustment - Number of Counterclockwise Turns to Increase Setting 5Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990024007Seal kit - Cartridge Polyurethane: 990024002Seal kit - Cartridge Viton: 990024006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(G)FUNCTIONAL SETTING RANGEG 2000 - 6000 psi (140 - 420 bar), 4000
psi (280 bar) Standard SettingF 1000 - 2500 psi (70 - 175 bar), 2000 psi
(140 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/CWIL
Model Code Example: CWILLGNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 116 of 207
MODELCWCA
3:1 pilot ratio, vented counterbalance valveSERIES 1 / CAPACITY: 60 L/min. / CAVITY: T-21A
4-Port Vented
4-Port Vented, Non-adjustable
Vented counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allowsfree flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valvecontrols flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a ratedetermined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because the spring chamberreferences the vent (port 4).
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 3:1Maximum Recommended Load Pressure at Maximum Setting 215 barMaximum Setting 280 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 2,8 barAdjustment - Number of Counterclockwise Turns to Increase Setting 5Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990021007Seal kit - Cartridge Polyurethane: 990021002Seal kit - Cartridge Viton: 990021006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi (70 - 280 bar), 3000 psi
(210 bar) Standard SettingI 400 - 1500 psi (28 - 105 bar), 1000 psi
(70 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/CWCA
Model Code Example: CWCALHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 117 of 207
MODELCWEA
3:1 pilot ratio, vented counterbalance valveSERIES 2 / CAPACITY: 120 L/min. / CAVITY: T-22A
4-Port Vented
4-Port Vented, Non-adjustable
Vented counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allowsfree flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valvecontrols flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a ratedetermined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because the spring chamberreferences the vent (port 4).
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 3:1Maximum Recommended Load Pressure at Maximum Setting 215 barMaximum Setting 280 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barAdjustment - Number of Counterclockwise Turns to Increase Setting 5Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990022007Seal kit - Cartridge Polyurethane: 990022002Seal kit - Cartridge Viton: 990022006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi (70 - 280 bar), 3000 psi
(210 bar) Standard SettingI 400 - 1500 psi (28 - 105 bar), 1000 psi
(70 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/CWEA
Model Code Example: CWEALHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 118 of 207
MODELCWGA
3:1 pilot ratio, vented counterbalance valveSERIES 3 / CAPACITY: 240 L/min. / CAVITY: T-23A
4-Port Vented
4-Port Vented, Non-adjustable
Vented counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allowsfree flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valvecontrols flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a ratedetermined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because the spring chamberreferences the vent (port 4).
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 3:1Maximum Recommended Load Pressure at Maximum Setting 215 barMaximum Setting 280 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barAdjustment - Number of Counterclockwise Turns to Increase Setting 5Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990023007Seal kit - Cartridge Polyurethane: 990023002Seal kit - Cartridge Viton: 990023006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi (70 - 280 bar), 3000 psi
(210 bar) Standard SettingI 400 - 1500 psi (28 - 105 bar), 1000 psi(70 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated
snhy.com/CWGA
Model Code Example: CWGALHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 119 of 207
MODELCWIA
3:1 pilot ratio, vented counterbalance valveSERIES 4 / CAPACITY: 480 L/min. / CAVITY: T-24A
4-Port Vented
4-Port Vented, Non-adjustable
Vented counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allowsfree flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valvecontrols flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a ratedetermined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because the spring chamberreferences the vent (port 4).
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 3:1Maximum Recommended Load Pressure at Maximum Setting 215 barMaximum Setting 280 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,5 barAdjustment - Number of Counterclockwise Turns to Increase Setting 5Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990024007Seal kit - Cartridge Polyurethane: 990024002Seal kit - Cartridge Viton: 990024006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi (70 - 280 bar), 3000 psi
(210 bar) Standard SettingI 400 - 1500 psi (28 - 105 bar), 1000 psi
(70 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/CWIA
Model Code Example: CWIALHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 120 of 207
MODELCWCG
5:1 pilot ratio, vented counterbalance valveSERIES 1 / CAPACITY: 60 L/min. / CAVITY: T-21A
4-Port Vented
4-Port Vented, Non-adjustable
Vented counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allowsfree flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valvecontrols flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a ratedetermined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because the spring chamberreferences the vent (port 4).
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 5:1Maximum Recommended Load Pressure at Maximum Setting 320 barMaximum Setting 420 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 2,8 barAdjustment - Number of Counterclockwise Turns to Increase Setting 5Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990021007Seal kit - Cartridge Polyurethane: 990021002Seal kit - Cartridge Viton: 990021006
(L)CONTROLL Standard Screw Adjustment
C Tamper Resistant - Factory Set
(G)FUNCTIONAL SETTING RANGEG 2000 - 6000 psi (140 - 420 bar), 4000
psi (280 bar) Standard SettingF 1000 - 2500 psi (70 - 175 bar), 2000 psi
(140 bar) Standard Setting
(N)SEAL MATERIALN Buna-N
V Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/CWCG
Model Code Example: CWCGLGNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 121 of 207
MODELCWEG
5:1 pilot ratio, vented counterbalance valveSERIES 2 / CAPACITY: 120 L/min. / CAVITY: T-22A
4-Port Vented
4-Port Vented, Non-adjustable
Vented counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allowsfree flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valvecontrols flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a ratedetermined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because the spring chamberreferences the vent (port 4).
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 5:1Maximum Recommended Load Pressure at Maximum Setting 320 barMaximum Setting 420 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barAdjustment - Number of Counterclockwise Turns to Increase Setting 5Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990022007Seal kit - Cartridge Polyurethane: 990022002Seal kit - Cartridge Viton: 990022006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(G)FUNCTIONAL SETTING RANGEG 2000 - 6000 psi (140 - 420 bar), 4000
psi (280 bar) Standard SettingF 1000 - 2500 psi (70 - 175 bar), 2000 psi
(140 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/CWEG
Model Code Example: CWEGLGNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 122 of 207
MODELCWGG
5:1 pilot ratio, vented counterbalance valveSERIES 3 / CAPACITY: 240 L/min. / CAVITY: T-23A
4-Port Vented
4-Port Vented, Non-adjustable
Vented counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allowsfree flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valvecontrols flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a ratedetermined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because the spring chamberreferences the vent (port 4).
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 5:1Maximum Recommended Load Pressure at Maximum Setting 320 barMaximum Setting 420 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barAdjustment - Number of Counterclockwise Turns to Increase Setting 5Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990023007Seal kit - Cartridge Polyurethane: 990023002Seal kit - Cartridge Viton: 990023006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(G)FUNCTIONAL SETTING RANGEG 2000 - 6000 psi (140 - 420 bar), 4000
psi (280 bar) Standard SettingF 1000 - 2500 psi (70 - 175 bar), 2000 psi(140 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/CWGG
Model Code Example: CWGGLGNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 123 of 207
MODELCWIG
5:1 pilot ratio, vented counterbalance valveSERIES 4 / CAPACITY: 480 L/min. / CAVITY: T-24A
4-Port Vented
4-Port Vented, Non-adjustable
Vented counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allowsfree flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valvecontrols flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a ratedetermined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because the spring chamberreferences the vent (port 4).
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 5:1Maximum Recommended Load Pressure at Maximum Setting 320 barMaximum Setting 420 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,5 barAdjustment - Number of Counterclockwise Turns to Increase Setting 5Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990024007Seal kit - Cartridge Polyurethane: 990024002Seal kit - Cartridge Viton: 990024006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(G)FUNCTIONAL SETTING RANGEG 2000 - 6000 psi (140 - 420 bar), 4000
psi (280 bar) Standard SettingF 1000 - 2500 psi (70 - 175 bar), 2000 psi(140 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/CWIG
Model Code Example: CWIGLGNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 124 of 207
MODELMBEM
Balanced load control valveSERIES 2 / CAPACITY: 120 L/min. / CAVITY: T-2A
Balanced load control valves combine a balanced modulating element with a reverse flow check. The check valveallows free flow from the directional valve (port 2) to the load (port 1) while the pilot to open modulating elementcontrols flow from port 1 to port 2. Pilot pressure at port 3 determines the flow setting.
TECHNICAL DATAMaximum Operating Pressure 350 barMaximum Valve Leakage at Reseat See Technical FeaturesCheck Cracking Pressure 1,7 barSeal kit - Cartridge Buna: 990202007Seal kit - Cartridge Polyurethane: 990002002Seal kit - Cartridge Viton: 990202009
(X)CONTROLX Not Adjustable
(I)MINIMUM CONTROL PRESSUREI 300 psi (20 bar)E 75 psi (5 bar)G 150 psi (10,5 bar)H 200 psi (14 bar)K 450 psi (33 bar)M 525 psi (39,7 bar)
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/MBEM
Model Code Example: MBEMXINCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 125 of 207
MODELMBGM
Balanced load control valveSERIES 3 / CAPACITY: 240 L/min. / CAVITY: T-17A
Balanced load control valves combine a balanced modulating element with a reverse flow check. The check valveallows free flow from the directional valve (port 2) to the load (port 1) while the pilot to open modulating elementcontrols flow from port 1 to port 2. Pilot pressure at port 3 determines the flow setting.
TECHNICAL DATAMaximum Operating Pressure 350 barMaximum Valve Leakage at Reseat See Technical FeaturesCheck Cracking Pressure 1,7 barSeal kit - Cartridge Buna: 990017007Seal kit - Cartridge Polyurethane: 990017002Seal kit - Cartridge Viton: 990017006
(X)CONTROLX Not Adjustable
(I)MINIMUM CONTROL PRESSUREI 300 psi (20 bar)E 75 psi (5 bar)G 150 psi (10,5 bar)K 450 psi (33 bar)M 525 psi (36,7 bar)
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/LH Mild Steel, Zinc-Nickel
snhy.com/MBGM
Model Code Example: MBGMXINCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 126 of 207
MODELMBIM
Balanced load control valveSERIES 4 / CAPACITY: 480 L/min. / CAVITY: T-19A
Balanced load control valves combine a balanced modulating element with a reverse flow check. The check valveallows free flow from the directional valve (port 2) to the load (port 1) while the pilot to open modulating elementcontrols flow from port 1 to port 2. Pilot pressure at port 3 determines the flow setting.
TECHNICAL DATAMaximum Operating Pressure 350 barMaximum Valve Leakage at Reseat See Technical FeaturesCheck Cracking Pressure 1,7 bar
(X)CONTROLX Not Adjustable
(I)MINIMUM CONTROL PRESSUREI 300 psi (20 bar)E 75 psi (5 bar)G 100 psi (7 bar)H 200 psi (14 bar)K 450 psi (33 bar)M 525 psi (36,7 bar)
(N)SEAL MATERIALN Buna-NE EPDMV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated
snhy.com/MBIM
Model Code Example: MBIMXINCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 127 of 207
MODELMWEM
Vented, balanced, load control valveSERIES 2 / CAPACITY: 120 L/min. / CAVITY: T-22A
Vented, balanced load control valves combine a balanced modulating element with a reverse flow check. Thecheck valve allows free flow from the directional valve (port 2) to the load (port 1) while the pilot to open modulatingelement controls flow from port 1 to port 2. Pilot pressure at port 3 determines the flow setting. Backpressure at port2 does not affect the flow setting because the spring chamber references the vent (port 4).
TECHNICAL DATAMaximum Operating Pressure 350 barMaximum Valve Leakage at Reseat See Technical FeaturesCheck Cracking Pressure 1,7 barSeal kit - Cartridge Buna: 990022007Seal kit - Cartridge Polyurethane: 990022002Seal kit - Cartridge Viton: 990022006
(X)CONTROLX Not Adjustable
(I)MINIMUM CONTROL PRESSUREI 300 psi (20 bar)E 75 psi (5 bar)G 150 psi (10,5 bar)H 200 psi (14 bar)K 450 psi (33 bar)M 525 psi (36,7 bar)
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/LH Mild Steel, Zinc-Nickel
snhy.com/MWEM
Model Code Example: MWEMXINCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 128 of 207
MODELMWGM
Vented, balanced, load control valveSERIES 3 / CAPACITY: 240 L/min. / CAVITY: T-23A
Vented, balanced load control valves combine a balanced modulating element with a reverse flow check. Thecheck valve allows free flow from the directional valve (port 2) to the load (port 1) while the pilot to open modulatingelement controls flow from port 1 to port 2. Pilot pressure at port 3 determines the flow setting. Backpressure at port2 does not affect the flow setting because the spring chamber references the vent (port 4).
TECHNICAL DATAMaximum Operating Pressure 350 barMaximum Valve Leakage at Reseat See Technical FeaturesCheck Cracking Pressure 1,7 barSeal kit - Cartridge Buna: 990023007Seal kit - Cartridge Polyurethane: 990023002Seal kit - Cartridge Viton: 990023006
(X)CONTROLX Not Adjustable
(I)MINIMUM CONTROL PRESSUREI 300 psi (20 bar)E 75 psi (5 bar)G 150 psi (10,5 bar)K 450 psi (33 bar)M 525 psi (36,7 bar)
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated
snhy.com/MWGM
Model Code Example: MWGMXINCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 129 of 207
MODELMWIM
Vented, balanced, load control valveSERIES 4 / CAPACITY: 480 L/min. / CAVITY: T-24A
Vented, balanced load control valves combine a balanced modulating element with a reverse flow check. Thecheck valve allows free flow from the directional valve (port 2) to the load (port 1) while the pilot to open modulatingelement controls flow from port 1 to port 2. Pilot pressure at port 3 determines the flow setting. Backpressure at port2 does not affect the flow setting because the spring chamber references the vent (port 4).
TECHNICAL DATAMaximum Operating Pressure 350 barMaximum Valve Leakage at Reseat See Technical FeaturesCheck Cracking Pressure 1,7 barSeal kit - Cartridge Buna: 990024007Seal kit - Cartridge Polyurethane: 990024002Seal kit - Cartridge Viton: 990024006
(X)CONTROLX Not Adjustable
(I)MINIMUM CONTROL PRESSUREI 300 psi (20 bar)E 75 psi (5 bar)G 150 psi (10,5 bar)H 200 psi (14 bar)K 450 psi (33 bar)M 525 psi (36,7 bar)
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated
snhy.com/MWIM
Model Code Example: MWIMXINCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 130 of 207
MODELMBDB
1.5:1 pilot ratio, load reactive load control valveSERIES 1 / CAPACITY: 60 L/min. / CAVITY: T-11A
3-Port Non-vented
Load reactive, load control valves with pilot assist combine two valves; a check valve and a relief valve. The checkvalve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted reliefvalve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a ratedetermined by the pilot ratio.
TECHNICAL DATAPilot Ratio 1.5:1Maximum Recommended Load Pressure at Maximum Setting 270 barMaximum Setting 350 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barAdjustment - Number of Counterclockwise Turns to Increase Setting 6.5Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990011007Seal kit - Cartridge Polyurethane: 990011002Seal kit - Cartridge Viton: 990011006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi (70 - 280 bar), 3000 psi
(210 bar) Standard SettingJ 2000 - 5000 psi (140 - 350 bar), 3000
psi (210 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/MBDB
Model Code Example: MBDBLHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 131 of 207
MODELMBEB
1.5:1 pilot ratio, load reactive load control valveSERIES 2 / CAPACITY: 120 L/min. / CAVITY: T-2A
3-Port Non-vented
Load reactive, load control valves with pilot assist combine two valves; a check valve and a relief valve. The checkvalve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted reliefvalve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a ratedetermined by the pilot ratio.
TECHNICAL DATAPilot Ratio 1.5:1Maximum Recommended Load Pressure at Maximum Setting 260 barMaximum Setting 350 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barAdjustment - Number of Counterclockwise Turns to Increase Setting 9Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990202007Seal kit - Cartridge Polyurethane: 990002002Seal kit - Cartridge Viton: 990202006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi (70 - 280 bar), 3000 psi
(210 bar) Standard SettingJ 2000 - 5000 psi (140 - 350 bar), 3000
psi (210 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/MBEB
Model Code Example: MBEBLHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 132 of 207
MODELMBGB
1.5:1 pilot ratio, load reactive load control valveSERIES 3 / CAPACITY: 240 L/min. / CAVITY: T-17A
3-Port Non-vented
Load reactive, load control valves with pilot assist combine two valves; a check valve and a relief valve. The checkvalve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted reliefvalve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a ratedetermined by the pilot ratio.
TECHNICAL DATAPilot Ratio 1.5:1Maximum Recommended Load Pressure at Maximum Setting 260 barMaximum Setting 350 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barAdjustment - Number of Counterclockwise Turns to Increase Setting 9Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990017007Seal kit - Cartridge Polyurethane: 990017002Seal kit - Cartridge Viton: 990017006
(L)CONTROLL Standard Screw Adjustment
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi (70 - 280 bar), 3000 psi
(210 bar) Standard SettingJ 2000 - 5000 psi (140 - 350 bar), 3000
psi (210 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated
snhy.com/MBGB
Model Code Example: MBGBLHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 133 of 207
MODELMBIB
1.5:1 pilot ratio, load reactive load control valveSERIES 4 / CAPACITY: 480 L/min. / CAVITY: T-19A
3-Port Non-vented
Load reactive, load control valves with pilot assist combine two valves; a check valve and a relief valve. The checkvalve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted reliefvalve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a ratedetermined by the pilot ratio.
TECHNICAL DATAPilot Ratio 1.5:1Maximum Recommended Load Pressure at Maximum Setting 260 barMaximum Setting 350 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barAdjustment - Number of Counterclockwise Turns to Increase Setting 7Reseat >85% of settingLocknut Hex Size 19,1 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990019007Seal kit - Cartridge Polyurethane: 990019002Seal kit - Cartridge Viton: 990019006
(L)CONTROLL Standard Screw Adjustment
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi (70 - 280 bar), 3000 psi
(210 bar) Standard SettingJ 2000 - 5000 psi (140 - 350 bar), 3000
psi (210 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated
snhy.com/MBIB
Model Code Example: MBIBLHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 134 of 207
MODELMBDA
3:1 pilot ratio, load reactive load control valveSERIES 1 / CAPACITY: 60 L/min. / CAVITY: T-11A
3-Port Non-vented
Load reactive, load control valves with pilot assist combine two valves; a check valve and a relief valve. The checkvalve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted reliefvalve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a ratedetermined by the pilot ratio.
TECHNICAL DATAPilot Ratio 3:1Maximum Recommended Load Pressure at Maximum Setting 260 barMaximum Setting 350 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barAdjustment - Number of Counterclockwise Turns to Increase Setting 6.5Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990011007Seal kit - Cartridge Polyurethane: 990011002Seal kit - Cartridge Viton: 990011006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi (70 - 280 bar), 3000 psi
(210 bar) Standard SettingJ 2000 - 5000 psi (140 - 350 bar), 3000
psi (210 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/MBDA
Model Code Example: MBDALHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 135 of 207
MODELMBEA
3:1 pilot ratio, load reactive load control valveSERIES 2 / CAPACITY: 120 L/min. / CAVITY: T-2A
3-Port Non-vented
Load reactive, load control valves with pilot assist combine two valves; a check valve and a relief valve. The checkvalve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted reliefvalve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a ratedetermined by the pilot ratio.
TECHNICAL DATAPilot Ratio 3:1Maximum Recommended Load Pressure at Maximum Setting 260 barMaximum Setting 350 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barAdjustment - Number of Counterclockwise Turns to Increase Setting 9Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990202007Seal kit - Cartridge Polyurethane: 990002002Seal kit - Cartridge Viton: 990202006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi (70 - 280 bar), 3000 psi
(210 bar) Standard SettingJ 2000 - 5000 psi (140 - 350 bar), 3000
psi (210 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/MBEA
Model Code Example: MBEALHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 136 of 207
MODELMBGA
3:1 pilot ratio, load reactive load control valveSERIES 3 / CAPACITY: 240 L/min. / CAVITY: T-17A
3-Port Non-vented
Load reactive, load control valves with pilot assist combine two valves; a check valve and a relief valve. The checkvalve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted reliefvalve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a ratedetermined by the pilot ratio.
TECHNICAL DATAPilot Ratio 3:1Maximum Recommended Load Pressure at Maximum Setting 260 barMaximum Setting 350 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barAdjustment - Number of Counterclockwise Turns to Increase Setting 9Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990017007Seal kit - Cartridge EPDM: 990017014Seal kit - Cartridge Polyurethane: 990017002Seal kit - Cartridge Viton: 990017006
(L)CONTROLL Standard Screw Adjustment
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi (70 - 280 bar), 3000 psi
(210 bar) Standard SettingJ 2000 - 5000 psi (140 - 350 bar), 3000
psi (210 bar) Standard Setting
(N)SEAL MATERIALN Buna-NE EPDMV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated
snhy.com/MBGA
Model Code Example: MBGALHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 137 of 207
MODELMBIA
3:1 pilot ratio, load reactive load control valveSERIES 4 / CAPACITY: 480 L/min. / CAVITY: T-19A
3-Port Non-vented
Load reactive, load control valves with pilot assist combine two valves; a check valve and a relief valve. The checkvalve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted reliefvalve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a ratedetermined by the pilot ratio.
TECHNICAL DATAPilot Ratio 3:1Maximum Recommended Load Pressure at Maximum Setting 260 barMaximum Setting 350 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barAdjustment - Number of Counterclockwise Turns to Increase Setting 7Reseat >85% of settingLocknut Hex Size 19,1 mmLocknut Torque 35 - 40 NmSeal kit - Cartridge Buna: 990019007Seal kit - Cartridge Polyurethane: 990019002Seal kit - Cartridge Viton: 990019006
(L)CONTROLL Standard Screw Adjustment
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi (70 - 280 bar), 3000 psi
(210 bar) Standard SettingJ 2000 - 5000 psi (140 - 350 bar), 3000
psi (210 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated
snhy.com/MBIA
Model Code Example: MBIALHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 138 of 207
MODELMBDG
4.5:1 pilot ratio, load reactive load control valveSERIES 1 / CAPACITY: 60 L/min. / CAVITY: T-11A
3-Port Non-vented
Load reactive, load control valves with pilot assist combine two valves; a check valve and a relief valve. The checkvalve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted reliefvalve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a ratedetermined by the pilot ratio.
TECHNICAL DATAPilot Ratio 4.5:1Maximum Recommended Load Pressure at Maximum Setting 270 barMaximum Setting 350 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barAdjustment - Number of Counterclockwise Turns to Increase Setting 6.5Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990011007Seal kit - Cartridge Polyurethane: 990011002Seal kit - Cartridge Viton: 990011006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi (70 - 280 bar), 3000 psi
(210 bar) Standard SettingJ 2000 - 5000 psi (140 - 350 bar), 3000
psi (210 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/MBDG
Model Code Example: MBDGLHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 139 of 207
MODELMBEG
4.5:1 pilot ratio, load reactive load control valveSERIES 2 / CAPACITY: 120 L/min. / CAVITY: T-2A
3-Port Non-vented
Load reactive, load control valves with pilot assist combine two valves; a check valve and a relief valve. The checkvalve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted reliefvalve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a ratedetermined by the pilot ratio.
TECHNICAL DATAPilot Ratio 4.5:1Maximum Recommended Load Pressure at Maximum Setting 260 barMaximum Setting 350 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barAdjustment - Number of Counterclockwise Turns to Increase Setting 9Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990202007Seal kit - Cartridge Polyurethane: 990002002Seal kit - Cartridge Viton: 990202006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi (70 - 280 bar), 3000 psi
(210 bar) Standard SettingJ 2000 - 5000 psi (140 - 350 bar), 3000
psi (210 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/MBEG
Model Code Example: MBEGLHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 140 of 207
MODELMBGG
4.5:1 pilot ratio, load reactive load control valveSERIES 3 / CAPACITY: 240 L/min. / CAVITY: T-17A
3-Port Non-vented
Load reactive, load control valves with pilot assist combine two valves; a check valve and a relief valve. The checkvalve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted reliefvalve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a ratedetermined by the pilot ratio.
TECHNICAL DATAPilot Ratio 4.5:1Maximum Recommended Load Pressure at Maximum Setting 260 barMaximum Setting 350 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barAdjustment - Number of Counterclockwise Turns to Increase Setting 9Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990017007Seal kit - Cartridge Polyurethane: 990017002Seal kit - Cartridge Viton: 990017006
(L)CONTROLL Standard Screw Adjustment
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi (70 - 280 bar), 3000 psi
(210 bar) Standard SettingJ 2000 - 5000 psi (140 - 350 bar), 3000
psi (210 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/MBGG
Model Code Example: MBGGLHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 141 of 207
MODELMBIG
4.5:1 pilot ratio, load reactive load control valveSERIES 4 / CAPACITY: 480 L/min. / CAVITY: T-19A
3-Port Non-vented
Load reactive, load control valves with pilot assist combine two valves; a check valve and a relief valve. The checkvalve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted reliefvalve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a ratedetermined by the pilot ratio.
TECHNICAL DATAPilot Ratio 4.5:1Maximum Recommended Load Pressure at Maximum Setting 260 barMaximum Setting 350 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barAdjustment - Number of Counterclockwise Turns to Increase Setting 7Reseat >85% of settingLocknut Hex Size 19,1 mmLocknut Torque 35 - 40 NmSeal kit - Cartridge Buna: 990019007Seal kit - Cartridge Polyurethane: 990019002Seal kit - Cartridge Viton: 990019006
(L)CONTROLL Standard Screw Adjustment
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi (70 - 280 bar), 3000 psi
(210 bar) Standard SettingJ 2000 - 5000 psi (140 - 350 bar), 3000
psi (210 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/MBIG
Model Code Example: MBIGLHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 142 of 207
MODELMBEBX
Fixed setting, 1.5:1 pilot ratio, load reactive load control valveSERIES 2 / CAPACITY: 120 L/min. / CAVITY: T-2A
3-Port Non-vented, Fixed Setting
Fixed setting, load reactive, load control valves with pilot assist combine two valves; a check valve and a reliefvalve. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting,pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of therelief valve at a rate determined by the pilot ratio.
TECHNICAL DATAPilot Ratio 1.5:1Factory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barReseat >85% of settingSeal kit - Cartridge Buna: 990202007Seal kit - Cartridge Polyurethane: 990002002Seal kit - Cartridge Viton: 990202006
(L)FACTORY SETL 4000 psi (280 bar)K 3000 psi (210 bar)M 5000 psi (350 bar)
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/MBEBX
Model Code Example: MBEBXLNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 143 of 207
MODELMBGBX
Fixed setting, 1.5:1 pilot ratio, load reactive load control valveSERIES 3 / CAPACITY: 240 L/min. / CAVITY: T-17A
3-Port Non-vented, Fixed Setting
Fixed setting, load reactive, load control valves with pilot assist combine two valves; a check valve and a reliefvalve. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting,pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of therelief valve at a rate determined by the pilot ratio.
TECHNICAL DATAPilot Ratio 1.5:1Factory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barReseat >85% of settingSeal kit - Cartridge Buna: 990017007Seal kit - Cartridge Polyurethane: 990017002Seal kit - Cartridge Viton: 990017006
(L)FACTORY SETL 4000 psi (280 bar)K 3000 psi (210 bar)M 5000 psi (350 bar)
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/MBGBX
Model Code Example: MBGBXLNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 144 of 207
MODELMBIBX
Fixed setting, 1.5:1 pilot ratio, load reactive load control valveSERIES 4 / CAPACITY: 480 L/min. / CAVITY: T-19A
3-Port Non-vented, Fixed Setting
Fixed setting, load reactive, load control valves with pilot assist combine two valves; a check valve and a reliefvalve. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting,pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of therelief valve at a rate determined by the pilot ratio.
TECHNICAL DATAPilot Ratio 1.5:1Factory Pressure Settings Established at 30 cc/min.Maximum Operating Pressure 350 barMaximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barReseat >85% of settingSeal kit - Cartridge Buna: 990019007Seal kit - Cartridge Polyurethane: 990019002Seal kit - Cartridge Viton: 990019006
(L)FACTORY SETL 4000 psi (280 bar)K 3000 psi (210 bar)M 5000 psi (350 bar)
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/MBIBX
Model Code Example: MBIBXLNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 145 of 207
MODELMBEAX
Fixed setting, 3:1 pilot ratio, load reactive load control valveSERIES 2 / CAPACITY: 120 L/min. / CAVITY: T-2A
3-Port Non-vented, Fixed Setting
Fixed setting, load reactive, load control valves with pilot assist combine two valves; a check valve and a reliefvalve. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting,pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of therelief valve at a rate determined by the pilot ratio.
TECHNICAL DATAPilot Ratio 3:1Factory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barReseat >85% of settingSeal kit - Cartridge Buna: 990202007Seal kit - Cartridge Polyurethane: 990002002Seal kit - Cartridge Viton: 990202006
(L)FACTORY SETL 4000 psi (280 bar)K 3000 psi (210 bar)M 5000 psi (350 bar)
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/MBEAX
Model Code Example: MBEAXLNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 146 of 207
MODELMBGAX
Fixed setting, 3:1 pilot ratio, load reactive load control valveSERIES 3 / CAPACITY: 240 L/min. / CAVITY: T-17A
3-Port Non-vented, Fixed Setting
Fixed setting, load reactive, load control valves with pilot assist combine two valves; a check valve and a reliefvalve. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting,pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of therelief valve at a rate determined by the pilot ratio.
TECHNICAL DATAPilot Ratio 3:1Factory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barReseat >85% of settingSeal kit - Cartridge Buna: 990017007Seal kit - Cartridge EPDM: 990017014Seal kit - Cartridge Polyurethane: 990017002Seal kit - Cartridge Viton: 990017006
(L)FACTORY SETL 4000 psi (280 bar)K 3000 psi (210 bar)M 5000 psi (350 bar)
(N)SEAL MATERIALN Buna-NE EPDMV Viton
snhy.com/MBGAX
Model Code Example: MBGAXLNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 147 of 207
MODELMBIAX
Fixed setting, 3:1 pilot ratio, load reactive load control valveSERIES 4 / CAPACITY: 480 L/min. / CAVITY: T-19A
3-Port Non-vented, Fixed Setting
Fixed setting, load reactive, load control valves with pilot assist combine two valves; a check valve and a reliefvalve. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting,pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of therelief valve at a rate determined by the pilot ratio.
TECHNICAL DATAPilot Ratio 3:1Factory Pressure Settings Established at 30 cc/min.Maximum Operating Pressure 350 barMaximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barReseat >85% of settingSeal kit - Cartridge Buna: 990019007Seal kit - Cartridge Polyurethane: 990019002Seal kit - Cartridge Viton: 990019006
(L)FACTORY SETL 4000 psi (280 bar)K 3000 psi (210 bar)M 5000 psi (350 bar)
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/MBIAX
Model Code Example: MBIAXLNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 148 of 207
MODELMBEGX
Fixed setting, 4.5:1 pilot ratio, load reactive load control valveSERIES 2 / CAPACITY: 120 L/min. / CAVITY: T-2A
3-Port Non-vented, Fixed Setting
Fixed setting, load reactive, load control valves with pilot assist combine two valves; a check valve and a reliefvalve. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting,pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of therelief valve at a rate determined by the pilot ratio.
TECHNICAL DATAPilot Ratio 4.5:1Factory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barReseat >85% of settingSeal kit - Cartridge Buna: 990202007Seal kit - Cartridge Polyurethane: 990002002Seal kit - Cartridge Viton: 990202006
(L)FACTORY SETL 4000 psi (280 bar)K 3000 psi (210 bar)M 5000 psi (350 bar)
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/MBEGX
Model Code Example: MBEGXLNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 149 of 207
MODELMBGGX
Fixed setting, 4.5:1 pilot ratio, load reactive load control valveSERIES 3 / CAPACITY: 240 L/min. / CAVITY: T-17A
3-Port Non-vented, Fixed Setting
Fixed setting, load reactive, load control valves with pilot assist combine two valves; a check valve and a reliefvalve. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting,pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of therelief valve at a rate determined by the pilot ratio.
TECHNICAL DATAPilot Ratio 4.5:1Factory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barReseat >85% of settingSeal kit - Cartridge Buna: 990017007Seal kit - Cartridge Polyurethane: 990017002Seal kit - Cartridge Viton: 990017006
(L)FACTORY SETL 4000 psi (280 bar)K 3000 psi (210 bar)M 5000 psi (350 bar)
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/MBGGX
Model Code Example: MBGGXLNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 150 of 207
MODELMBIGX
Fixed setting, 4.5:1 pilot ratio, load reactive load control valveSERIES 4 / CAPACITY: 480 L/min. / CAVITY: T-19A
3-Port Non-vented, Fixed Setting
Fixed setting, load reactive, load control valves with pilot assist combine two valves; a check valve and a reliefvalve. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting,pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of therelief valve at a rate determined by the pilot ratio.
TECHNICAL DATAPilot Ratio 4.5:1Factory Pressure Settings Established at 30 cc/min.Maximum Operating Pressure 350 barMaximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barReseat >85% of settingSeal kit - Cartridge Buna: 990019007Seal kit - Cartridge Polyurethane: 990019002Seal kit - Cartridge Viton: 990019006
(L)FACTORY SETL 4000 psi (280 bar)K 3000 psi (210 bar)M 5000 psi (350 bar)
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/MBIGX
Model Code Example: MBIGXLNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 151 of 207
MODELMWEB
Vented, 1.5:1 pilot ratio, load reactive, load control valveSERIES 2 / CAPACITY: 120 L/min. / CAVITY: T-22A
4-Port Vented
Vented, load reactive load control valves with pilot assist combine two valves; a check valve and a relief valve. Thecheck valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the reliefvalve at a rate determined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because thespring chamber references the vent (port 4).
TECHNICAL DATAPilot Ratio 1.5:1Maximum Recommended Load Pressure at Maximum Setting 260 barMaximum Setting 350 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barAdjustment - Number of Counterclockwise Turns to Increase Setting 9Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990022007Seal kit - Cartridge Polyurethane: 990022002Seal kit - Cartridge Viton: 990022006
(L)CONTROLL Standard Screw Adjustment
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi (70 - 280 bar), 3000 psi
(210 bar) Standard SettingJ 2000 - 5000 psi (140 - 350 bar), 3000
psi (210 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/MWEB
Model Code Example: MWEBLHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 152 of 207
MODELMWGB
Vented, 1.5:1 pilot ratio, load reactive, load control valveSERIES 3 / CAPACITY: 240 L/min. / CAVITY: T-23A
4-Port Vented
Vented, load reactive load control valves with pilot assist combine two valves; a check valve and a relief valve. Thecheck valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the reliefvalve at a rate determined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because thespring chamber references the vent (port 4).
TECHNICAL DATAPilot Ratio 1.5:1Maximum Recommended Load Pressure at Maximum Setting 260 barMaximum Setting 350 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barAdjustment - Number of Counterclockwise Turns to Increase Setting 9Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990023007Seal kit - Cartridge Polyurethane: 990023002Seal kit - Cartridge Viton: 990023006
(L)CONTROLL Standard Screw Adjustment
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi (70 - 280 bar), 3000 psi
(210 bar) Standard SettingJ 2000 - 5000 psi (140 - 350 bar), 3000
psi (210 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/MWGB
Model Code Example: MWGBLHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 153 of 207
MODELMWEA
Vented, 3:1 pilot ratio, load reactive, load control valveSERIES 2 / CAPACITY: 120 L/min. / CAVITY: T-22A
4-Port Vented
Vented, load reactive load control valves with pilot assist combine two valves; a check valve and a relief valve. Thecheck valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the reliefvalve at a rate determined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because thespring chamber references the vent (port 4).
TECHNICAL DATAPilot Ratio 3:1Maximum Recommended Load Pressure at Maximum Setting 260 barMaximum Setting 350 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barAdjustment - Number of Counterclockwise Turns to Increase Setting 9Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990022007Seal kit - Cartridge Polyurethane: 990022002Seal kit - Cartridge Viton: 990022006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi (70 - 280 bar), 3000 psi
(210 bar) Standard SettingJ 2000 - 5000 psi (140 - 350 bar), 3000
psi (210 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/MWEA
Model Code Example: MWEALHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 154 of 207
MODELMWGA
Vented, 3:1 pilot ratio, load reactive, load control valveSERIES 3 / CAPACITY: 240 L/min. / CAVITY: T-23A
4-Port Vented
Vented, load reactive load control valves with pilot assist combine two valves; a check valve and a relief valve. Thecheck valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the reliefvalve at a rate determined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because thespring chamber references the vent (port 4).
TECHNICAL DATAPilot Ratio 3:1Maximum Recommended Load Pressure at Maximum Setting 260 barMaximum Setting 350 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barAdjustment - Number of Counterclockwise Turns to Increase Setting 8.5Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990023007Seal kit - Cartridge Polyurethane: 990023002Seal kit - Cartridge Viton: 990023006
(L)CONTROLL Standard Screw Adjustment
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi (70 - 280 bar), 3000 psi
(210 bar) Standard SettingJ 2000 - 5000 psi (140 - 350 bar), 3000
psi (210 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/MWGA
Model Code Example: MWGALHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 155 of 207
MODELMWIA
Vented, 3:1 pilot ratio, load reactive load control valveSERIES 4 / CAPACITY: 480 L/min. / CAVITY: T-24A
4-Port Vented
Vented, load reactive load control valves with pilot assist combine two valves; a check valve and a relief valve. Thecheck valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the reliefvalve at a rate determined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because thespring chamber references the vent (port 4).
TECHNICAL DATAPilot Ratio 3:1Maximum Recommended Load Pressure at Maximum Setting 260 barMaximum Setting 350 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barAdjustment - Number of Counterclockwise Turns to Increase Setting 8.5Reseat >85% of settingLocknut Hex Size 19,1 mmLocknut Torque 35 - 40 NmSeal kit - Cartridge Buna: 990024007Seal kit - Cartridge Polyurethane: 990024002Seal kit - Cartridge Viton: 990024006
(L)CONTROLL Standard Screw Adjustment
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi (70 - 280 bar), 3000 psi
(210 bar) Standard SettingJ 2000 - 5000 psi (140 - 350 bar), 3000
psi (210 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated
snhy.com/MWIA
Model Code Example: MWIALHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 156 of 207
MODELMWEG
Vented, 4.5:1 pilot ratio, load reactive, load control valveSERIES 2 / CAPACITY: 120 L/min. / CAVITY: T-22A
4-Port Vented
Vented, load reactive load control valves with pilot assist combine two valves; a check valve and a relief valve. Thecheck valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the reliefvalve at a rate determined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because thespring chamber references the vent (port 4).
TECHNICAL DATAPilot Ratio 4.5:1Maximum Recommended Load Pressure at Maximum Setting 260 barMaximum Setting 350 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barAdjustment - Number of Counterclockwise Turns to Increase Setting 8.5Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990022007Seal kit - Cartridge Polyurethane: 990022002Seal kit - Cartridge Viton: 990022006
(L)CONTROLL Standard Screw Adjustment
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi (70 - 280 bar), 3000 psi
(210 bar) Standard SettingJ 2000 - 5000 psi (140 - 350 bar), 3000
psi (210 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated
snhy.com/MWEG
Model Code Example: MWEGLHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 157 of 207
MODELMWGG
Vented, 4.5:1 pilot ratio, load reactive, load control valveSERIES 3 / CAPACITY: 240 L/min. / CAVITY: T-23A
4-Port Vented
Vented, load reactive load control valves with pilot assist combine two valves; a check valve and a relief valve. Thecheck valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the reliefvalve at a rate determined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because thespring chamber references the vent (port 4).
TECHNICAL DATAPilot Ratio 4.5:1Maximum Recommended Load Pressure at Maximum Setting 260 barMaximum Setting 350 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barAdjustment - Number of Counterclockwise Turns to Increase Setting 9Reseat >85% of settingSeal kit - Cartridge Buna: 990023007Seal kit - Cartridge Polyurethane: 990023002Seal kit - Cartridge Viton: 990023006
(L)CONTROLL Standard Screw Adjustment
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi (70 - 280 bar), 3000 psi
(210 bar) Standard SettingJ 2000 - 5000 psi (140 - 350 bar), 3000
psi (210 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/MWGG
Model Code Example: MWGGLHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 158 of 207
MODELMWIG
Vented, 4.5:1 pilot ratio, load reactive load control valveSERIES 4 / CAPACITY: 480 L/min. / CAVITY: T-24A
4-Port Vented
Vented, load reactive load control valves with pilot assist combine two valves; a check valve and a relief valve. Thecheck valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the reliefvalve at a rate determined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because thespring chamber references the vent (port 4).
TECHNICAL DATAPilot Ratio 4.5:1Maximum Recommended Load Pressure at Maximum Setting 260 barMaximum Setting 350 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barAdjustment - Number of Counterclockwise Turns to Increase Setting 8.5Reseat >85% of settingLocknut Hex Size 1☎,1 mmLocknut Torque 35 - 40 NmSeal kit - Cartridge Buna: ☎☎0024007Seal kit - Cartridge Polyurethane: ☎☎0024002Seal kit - Cartridge Viton: ☎☎0024006
(L)CONTROLL Standard Screw Adjustment
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi (70 - 280 bar), 3000 psi
(210 bar) Standard SettingJ 2000 - 5000 psi (140 - 350 bar), 3000
psi (210 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/MWIG
Model Code Example: MWIGLHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 159 of 207
MODELMWEBX
Vented, fixed setting, 1.5:1 pilot ratio, load reactive, load control valveSERIES 2 / CAPACITY: 120 L/min. / CAVITY: T-22A
4-Port Vented, Non-adjustable
Fixed setting, vented, load reactive load control valves with pilot assist combine two valves; a check valve and arelief valve. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective settingof the relief valve at a rate determined by the pilot ratio. Backpressure at port 2 does not affect the valve settingbecause the spring chamber references the vent (port 4).
TECHNICAL DATAPilot Ratio 1.5:1Factory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barReseat >85% of settingSeal kit - Cartridge Buna: 990022007Seal kit - Cartridge Polyurethane: 990022002Seal kit - Cartridge Viton: 990022006
(L)FACTORY SETL 4000 psi (280 bar)K 3000 psi (210 bar)M 5000 psi (350 bar)
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/MWEBX
Model Code Example: MWEBXLNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 160 of 207
MODELMWGBX
Vented, fixed setting, 1.5:1 pilot ratio, load reactive, load control valveSERIES 3 / CAPACITY: 240 L/min. / CAVITY: T-23A
4-Port Vented, Non-adjustable
Fixed setting, vented, load reactive load control valves with pilot assist combine two valves; a check valve and arelief valve. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective settingof the relief valve at a rate determined by the pilot ratio. Backpressure at port 2 does not affect the valve settingbecause the spring chamber references the vent (port 4).
TECHNICAL DATAPilot Ratio 1.5:1Factory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barReseat >85% of settingSeal kit - Cartridge Buna: 990023007Seal kit - Cartridge Polyurethane: 990023002Seal kit - Cartridge Viton: 990023006
(L)FACTORY SETL 4000 psi (280 bar)K 3000 psi (210 bar)M 5000 psi (350 bar)
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/MWGBX
Model Code Example: MWGBXLNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 161 of 207
MODELMWIBX
Fixed setting, vented, 1.5:1 pilot ratio, load reactive load control valveSERIES 4 / CAPACITY: 480 L/min. / CAVITY: T-24A
4-Port Vented, Non-adjustable
Fixed setting, vented, load reactive load control valves with pilot assist combine two valves; a check valve and arelief valve. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective settingof the relief valve at a rate determined by the pilot ratio. Backpressure at port 2 does not affect the valve settingbecause the spring chamber references the vent (port 4).
TECHNICAL DATAPilot Ratio 1.5:1Factory Pressure Settings Established at 30 cc/min.Maximum Operating Pressure 350 barMaximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barReseat >85% of settingSeal kit - Cartridge Buna: 990024007Seal kit - Cartridge Polyurethane: 990024002Seal kit - Cartridge Viton: 990024006
(L)FACTORY SETL 4000 psi (280 bar)K 3000 psi (210 bar)M 5000 psi (350 bar)
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/MWIBX
Model Code Example: MWIBXLNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 162 of 207
MODELMWEAX
Vented, fixed setting, 3:1 pilot ratio, load reactive, load control valveSERIES 2 / CAPACITY: 120 L/min. / CAVITY: T-22A
4-Port Vented, Non-adjustable
Fixed setting, vented, load reactive load control valves with pilot assist combine two valves; a check valve and arelief valve. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective settingof the relief valve at a rate determined by the pilot ratio. Backpressure at port 2 does not affect the valve settingbecause the spring chamber references the vent (port 4).
TECHNICAL DATAPilot Ratio 3:1Factory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barReseat >85% of settingSeal kit - Cartridge Buna: 990022007Seal kit - Cartridge Polyurethane: 990022002Seal kit - Cartridge Viton: 990022006
(L)FACTORY SETL 4000 psi (280 bar)K 3000 psi (210 bar)M 5000 psi (350 bar)
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/MWEAX
Model Code Example: MWEAXLNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 163 of 207
MODELMWGAX
Vented, fixed setting, 3:1 pilot ratio, load reactive, load control valveSERIES 3 / CAPACITY: 240 L/min. / CAVITY: T-23A
4-Port Vented, Non-adjustable
Fixed setting, vented, load reactive load control valves with pilot assist combine two valves; a check valve and arelief valve. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective settingof the relief valve at a rate determined by the pilot ratio. Backpressure at port 2 does not affect the valve settingbecause the spring chamber references the vent (port 4).
TECHNICAL DATAPilot Ratio 3:1Factory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barReseat >85% of settingSeal kit - Cartridge Buna: 990023007Seal kit - Cartridge Polyurethane: 990023002Seal kit - Cartridge Viton: 990023006
(L)FACTORY SETL 4000 psi (280 bar)K 3000 psi (210 bar)M 5000 psi (350 bar)
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/MWGAX
Model Code Example: MWGAXLNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 164 of 207
MODELMWIAX
Fixed setting, vented, 3:1 pilot ratio, load reactive load control valveSERIES 4 / CAPACITY: 480 L/min. / CAVITY: T-24A
4-Port Vented, Non-adjustable
Fixed setting, vented, load reactive load control valves with pilot assist combine two valves; a check valve and arelief valve. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective settingof the relief valve at a rate determined by the pilot ratio. Backpressure at port 2 does not affect the valve settingbecause the spring chamber references the vent (port 4).
TECHNICAL DATAPilot Ratio 3:1Factory Pressure Settings Established at 30 cc/min.Maximum Operating Pressure 350 barMaximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barReseat >85% of settingSeal kit - Cartridge Buna: 990024007Seal kit - Cartridge Polyurethane: 990024002Seal kit - Cartridge Viton: 990024006
(L)FACTORY SETL 4000 psi (280 bar)K 3000 psi (210 bar)M 5000 psi (350 bar)
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/MWIAX
Model Code Example: MWIAXLNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 165 of 207
MODELMWEGX
Vented, fixed setting, 4.5:1 pilot ratio, load reactive, load control valveSERIES 2 / CAPACITY: 120 L/min. / CAVITY: T-22A
4-Port Vented, Non-adjustable
Fixed setting, vented, load reactive load control valves with pilot assist combine two valves; a check valve and arelief valve. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective settingof the relief valve at a rate determined by the pilot ratio. Backpressure at port 2 does not affect the valve settingbecause the spring chamber references the vent (port 4).
TECHNICAL DATAPilot Ratio 4.5:1Factory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barReseat >85% of settingSeal kit - Cartridge Buna: 990022007Seal kit - Cartridge Polyurethane: 990022002Seal kit - Cartridge Viton: 990022006
(L)FACTORY SETL 4000 psi (280 bar)K 3000 psi (210 bar)M 5000 psi (350 bar)
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/MWEGX
Model Code Example: MWEGXLNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 166 of 207
MODELMWGGX
Vented, fixed setting, 4.5:1 pilot ratio, load reactive, load control valveSERIES 3 / CAPACITY: 240 L/min. / CAVITY: T-23A
4-Port Vented, Non-adjustable
Fixed setting, vented, load reactive load control valves with pilot assist combine two valves; a check valve and arelief valve. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective settingof the relief valve at a rate determined by the pilot ratio. Backpressure at port 2 does not affect the valve settingbecause the spring chamber references the vent (port 4).
TECHNICAL DATAPilot Ratio 4.5:1Factory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barReseat >85% of settingSeal kit - Cartridge Buna: 990023007Seal kit - Cartridge Polyurethane: 990023002Seal kit - Cartridge Viton: 990023006
(L)FACTORY SETL 4000 psi (280 bar)K 3000 psi (210 bar)M 5000 psi (350 bar)
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/MWGGX
Model Code Example: MWGGXLNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 167 of 207
MODELMWIGX
Fixed setting, vented, 4.5:1 pilot ratio, load reactive load control valveSERIES 4 / CAPACITY: 480 L/min. / CAVITY: T-24A
4-Port Vented, Non-adjustable
Fixed setting, vented, load reactive load control valves with pilot assist combine two valves; a check valve and arelief valve. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective settingof the relief valve at a rate determined by the pilot ratio. Backpressure at port 2 does not affect the valve settingbecause the spring chamber references the vent (port 4).
TECHNICAL DATAPilot Ratio 4.5:1Factory Pressure Settings Established at 30 cc/min.Maximum Operating Pressure 350 barMaximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barReseat >85% of settingSeal kit - Cartridge Buna: 990024007Seal kit - Cartridge Polyurethane: 990024002Seal kit - Cartridge Viton: 990024006
(L)FACTORY SETL 4000 psi (280 bar)K 3000 psi (210 bar)M 5000 psi (350 bar)
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/MWIGX
Model Code Example: MWIGXLNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 168 of 207
MODELMBDP
LoadMatch™ counterbalance valveSERIES 1 / CAPACITY: 60 L/min. / CAVITY: T-11A
3-Port Non-vented, Fixed Setting
These valves are self-setting counterbalance valves which combine multiple functions in one package; reverse freeflow, load, and thermal relief. The check allows free flow from the directional valve (port 2) to the load (port 1) whilea direct-acting pilot function self adjusts to approximately 1.3 times the load induced pressure up to the thermalrelief setting.
TECHNICAL DATAFactory Pressure Settings Established at 30 cc/min.Maximum Operating Pressure 350 barMaximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barReseat >85% of settingSeal kit - Cartridge Buna: 990011007Seal kit - Cartridge Polyurethane: 990011002Seal kit - Cartridge Viton: 990011006
(D)CONTROLD LoadMatch™
(H)FACTORY SETH 4000 psi (280 bar)J 5000 psi (350 bar)
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/MBDP
Patents are pending for this product.NOTES
Model Code Example: MBDPDHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 169 of 207
MODELMBEP
LoadMatch™ counterbalance valveSERIES 2 / CAPACITY: 120 L/min. / CAVITY: T-2A
3-Port Non-vented, Fixed Setting
These valves are self-setting counterbalance valves which combine multiple functions in one package; reverse freeflow, load, and thermal relief. The check allows free flow from the directional valve (port 2) to the load (port 1) whilea direct-acting pilot function self adjusts to approximately 1.3 times the load induced pressure up to the thermalrelief setting.
TECHNICAL DATAFactory Pressure Settings Established at 30 cc/min.Maximum Operating Pressure 350 barMaximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barReseat >85% of settingSeal kit - Cartridge Buna: 990202007Seal kit - Cartridge Polyurethane: 990002002Seal kit - Cartridge Viton: 990202006
(D)CONTROLD LoadMatch™
(H)FACTORY SETH 4000 psi (280 bar)G 6000 psi (420 bar)J 5000 psi (350 bar)
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/MBEP
Patents are pending for this product.NOTES
Model Code Example: MBEPDHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 170 of 207
MODELMBGP
LoadMatch™ counterbalance valveSERIES 3 / CAPACITY: 240 L/min. / CAVITY: T-17A
3-Port Non-vented, Fixed Setting
These valves are self-setting counterbalance valves which combine multiple functions in one package; reverse freeflow, load, and thermal relief. The check allows free flow from the directional valve (port 2) to the load (port 1) whilea direct-acting pilot function self adjusts to approximately 1.3 times the load induced pressure up to the thermalrelief setting.
TECHNICAL DATAFactory Pressure Settings Established at 30 cc/min.Maximum Operating Pressure 350 barMaximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barReseat >85% of settingSeal kit - Cartridge Buna: 990017007Seal kit - Cartridge Polyurethane: 990017002Seal kit - Cartridge Viton: 990017006
(D)CONTROLD LoadMatch™
(H)FACTORY SETH 4000 psi (280 bar)G 6000 psi (420 bar)J 5000 psi (350 bar)
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated
snhy.com/MBGP
Model Code Example: MBGPDHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 171 of 207
MODELMADP
Atmospherically referenced, LoadMatch™ counterbalance valveSERIES 1 / CAPACITY: 60 L/min. / CAVITY: T-11A
3-Port Atmospherically Referenced, Non-adjustableThese valves are self-setting counterbalance valves which combine multiple functions in one package; reverse freeflow, load, and thermal relief. The check allows free flow from the directional valve (port 2) to the load (port 1) whilea direct-acting pilot function self adjusts to approximately 1.3 times the load induced pressure up to the thermalrelief setting.
TECHNICAL DATAFactory Pressure Settings Established at 30 cc/min.Maximum Operating Pressure 350 barMaximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barReseat >85% of settingSeal kit - Cartridge Buna: 990011007Seal kit - Cartridge Viton: 990011006
(D)CONTROLD LoadMatch™
(H)FACTORY SETH 4000 psi (280 bar)J 5000 psi (350 bar)
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/MADP
Patents are pending for this product.NOTES
Model Code Example: MADPDHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 172 of 207
MODELMAEP
Atmospherically referenced, LoadMatch™ counterbalance valveSERIES 2 / CAPACITY: 120 L/min. / CAVITY: T-2A
3-Port Atmospherically Referenced, Non-adjustable
These valves are self-setting counterbalance valves which combine multiple functions in one package; reverse freeflow, load, and thermal relief. The check allows free flow from the directional valve (port 2) to the load (port 1) whilea direct-acting pilot function self adjusts to approximately 1.3 times the load induced pressure up to the thermalrelief setting. Backpressure at port 2 does not affect self setting performance because the spring chamberreferences the atmosphere.
TECHNICAL DATAFactory Pressure Settings Established at 30 cc/min.Maximum Operating Pressure 350 barMaximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barReseat >85% of settingSeal kit - Cartridge Buna: 990202007Seal kit - Cartridge Polyurethane: 990002002Seal kit - Cartridge Viton: 990202006
(D)CONTROLD LoadMatch™
(H)FACTORY SETH 4000 psi (280 bar)G 6000 psi (420 bar)J 5000 psi (350 bar)
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/LH Mild Steel, Zinc-Nickel
snhy.com/MAEP
NOTES Patents are pending for this product.The pressures listed under FACTORY SET are approximate, mean values and should not be used for inspection purposes.
Model Code Example: MAEPDHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 173 of 207
MODELMAGP
Atmospherically referenced, LoadMatch™ counterbalance valveSERIES 3 / CAPACITY: 240 L/min. / CAVITY: T-17A
3-Port Atmospherically Referenced, Non-adjustable
These valves are self-setting counterbalance valves which combine multiple functions in one package; reverse freeflow, load, and thermal relief. The check allows free flow from the directional valve (port 2) to the load (port 1) whilea direct-acting pilot function self adjusts to approximately 1.3 times the load induced pressure up to the thermalrelief setting. Backpressure at port 2 does not affect self setting performance because the spring chamberreferences the atmosphere.
TECHNICAL DATAFactory Pressure Settings Established at 30 cc/min.Maximum Operating Pressure 350 barMaximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barReseat >85% of settingSeal kit - Cartridge Buna: 990017007Seal kit - Cartridge Polyurethane: 990017002Seal kit - Cartridge Viton: 990117006
(D)CONTROLD LoadMatch™
(H)FACTORY SETH 4000 psi (280 bar)G 6000 psi (420 bar)J 5000 psi (350 bar)
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/MAGP
Model Code Example: MAGPDHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 174 of 207
MODELMWDP
Vented LoadMatch™ counterbalance valveSERIES 1 / CAPACITY: 60 L/min. / CAVITY: T-21A
4-Port Vented, Non-adjustable
These valves are self-setting counterbalance valves which combine multiple functions in one package; reverse freeflow, load, and thermal relief. The check allows free flow from the directional valve (port 2) to the load (port 1) whilea direct-acting pilot function self adjusts to approximately 1.3 times the load induced pressure up to the thermalrelief setting. Backpressure at port 2 does not affect self setting performance because the spring chamberreferences the vent (port 4).
TECHNICAL DATAFactory Pressure Settings Established at 30 cc/min.Maximum Operating Pressure 350 barMaximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barReseat >85% of settingSeal kit - Cartridge Buna: 990021007Seal kit - Cartridge Polyurethane: 990021002Seal kit - Cartridge Viton: 990021006
(D)CONTROLD LoadMatch™
(H)FACTORY SETH 4000 psi (280 bar)J 5000 psi (350 bar)
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/LH Mild Steel, Zinc-Nickel
snhy.com/MWDP
Patents are pending for this product.NOTES
Model Code Example: MWDPDHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 175 of 207
MODELMWEP
Vented LoadMatch™ counterbalance valveSERIES 2 / CAPACITY: 120 L/min. / CAVITY: T-22A
4-Port Vented, Non-adjustable
These valves are self-setting counterbalance valves which combine multiple functions in one package; reverse freeflow, load, and thermal relief. The check allows free flow from the directional valve (port 2) to the load (port 1) whilea direct-acting pilot function self adjusts to approximately 1.3 times the load induced pressure up to the thermalrelief setting. Backpressure at port 2 does not affect self setting performance because the spring chamberreferences the vent (port 4).
TECHNICAL DATAFactory Pressure Settings Established at 30 cc/min.Maximum Operating Pressure 350 barMaximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barReseat >85% of settingSeal kit - Cartridge Buna: 990022007Seal kit - Cartridge Polyurethane: 990022002Seal kit - Cartridge Viton: 990022006
(D)CONTROLD LoadMatch™
(H)FACTORY SETH 4000 psi (280 bar)G 6000 psi (420 bar)J 5000 psi (350 bar)
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/MWEP
Patents are pending for this product.NOTES
Model Code Example: MWEPDHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 176 of 207
MODELMWGP
Vented LoadMatch™ counterbalance valveSERIES 3 / CAPACITY: 240 L/min. / CAVITY: T-23A
4-Port Vented, Non-adjustable
These valves are self-setting counterbalance valves which combine multiple functions in one package; reverse freeflow, load, and thermal relief. The check allows free flow from the directional valve (port 2) to the load (port 1) whilea direct-acting pilot function self adjusts to approximately 1.3 times the load induced pressure up to the thermalrelief setting. Backpressure at port 2 does not affect self setting performance because the spring chamberreferences the vent (port 4).
TECHNICAL DATAFactory Pressure Settings Established at 30 cc/min.Maximum Operating Pressure 350 barMaximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barReseat >85% of settingSeal kit - Cartridge Buna: 990023007Seal kit - Cartridge Polyurethane: 990023002Seal kit - Cartridge Viton: 990023006
(D)CONTROLD LoadMatch™
(H)FACTORY SETH 4000 psi (280 bar)G 6000 psi (420 bar)J 5000 psi (350 bar)
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated
snhy.com/MWGP
Model Code Example: MWGPDHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 177 of 207
MODELMWIB
Vented, 1.5:1 pilot ratio, load reactive load control valveSERIES 4 / CAPACITY: 480 L/min. / CAVITY: T-24A
4-Port Vented
Vented, load reactive load control valves with pilot assist combine two valves; a check valve and a relief valve. Thecheck valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the reliefvalve at a rate determined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because thespring chamber references the vent (port 4).
TECHNICAL DATAPilot Ratio 1.5:1Maximum Recommended Load Pressure at Maximum Setting 260 barMaximum Setting 350 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barAdjustment - Number of Counterclockwise Turns to Increase Setting 8.5Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 35 - 40 NmSeal kit - Cartridge Buna: 990024007Seal kit - Cartridge Polyurethane: 990024002Seal kit - Cartridge Viton: 990024006
(L)CONTROLL Standard Screw Adjustment
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi (70 - 280 bar), 3000 psi
(210 bar) Standard SettingJ 2000 - 5000 psi (140 - 350 bar), 3000
psi (210 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/MWIB
Model Code Example: MWIBLHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 178 of 207
MODELCKBB
Pilot-to-open check valve with standard pilotCAPACITY: 30 L/min. / CAVITY: T-163A
This valve is a pilot to open check valve. It has a non-sealed pilot, a steel seat, and is non-vented. It allows freeflow from the valve (port 2) to the load (port 1) and blocks flow in the opposite direction. Pressure at the pilot (port3) will open the valve from port 1 to port 2. Pilot pressure needed at port 3 to open the valve is directly proportionalto the load pressure at port 1. Pressure at port 2 directly opposes pilot pressure.
TECHNICAL DATAPilot Ratio 3:1Maximum Operating Pressure 350 barMaximum Valve Leakage at 110 SUS (24 cSt) 0,07 cc/min.Seal kit - Cartridge Buna: 990163007Seal kit - Cartridge Polyurethane: 990163002Seal kit - Cartridge Viton: 990163006
(X)CONTROLX Standard PilotL Manual Load Release
(C)CRACKING PRESSUREC 30 psi (2 bar)E 75 psi (5 bar)
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/CKBB
Model Code Example: CKBBXCNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 179 of 207
MODELCKBG
Flush mount pilot-to-open check valve with sealed pilotCAPACITY: 30 L/min. / CAVITY: T-163A
This valve is a pilot to open check valve. It has a sealed pilot, a steel seat, and is non-vented. It allows free flowfrom the valve (port 2) to the load (port 1) and blocks flow in the opposite direction. Pressure at the pilot (port 3) willopen the valve from port 1 to port 2. Pilot pressure needed at port 3 to open the valve is directly proportional to theload pressure at port 1. Pressure at port 2 directly opposes pilot pressure.
TECHNICAL DATAPilot Ratio 3:1Maximum Operating Pressure 350 barMaximum Valve Leakage at 110 SUS (24 cSt) 0,07 cc/min.Valve Internal Hex Size 8 mmSeal kit - Cartridge Buna: 990163007Seal kit - Cartridge Polyurethane: 990163002Seal kit - Cartridge Viton: 990163006
(X)CONTROLX Not Adustable, Standard Hydraulic Pilot
(C)BIAS PRESSUREC 30 psi (2 bar)E 75 psi (5 bar)
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated
snhy.com/CKBG
Model Code Example: CKBGXCNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 180 of 207
MODELCKCB
Pilot-to-open check valve with standard pilotSERIES 1 / CAPACITY: 60 L/min. / CAVITY: T-11A
This valve is a pilot to open check valve. It has a non-sealed pilot, a steel seat, and is non-vented. It allows freeflow from the valve (port 2) to the load (port 1) and blocks flow in the opposite direction. Pressure at the pilot (port3) will open the valve from port 1 to port 2. Pilot pressure needed at port 3 to open the valve is directly proportionalto the load pressure at port 1. Pressure at port 2 directly opposes pilot pressure.
TECHNICAL DATAPilot Ratio 3:1Maximum Operating Pressure 350 barMaximum Valve Leakage at 110 SUS (24 cSt) 0,07 cc/min.Seal kit - Cartridge Buna: 990011007Seal kit - Cartridge EPDM: 990011014Seal kit - Cartridge Polyurethane: 990011002Seal kit - Cartridge Viton: 990011006
(X)CONTROLX Standard PilotL Manual Load Release
(C)CRACKING PRESSUREC 30 psi (2 bar)A 4 psi (0,3 bar)B 15 psi (1 bar)D 50 psi (3,5 bar)E 75 psi (5 bar)F 100 psi (7 bar)
(N)SEAL MATERIALN Buna-NE EPDMV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/CKCB
Model Code Example: CKCBXCNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 181 of 207
MODELCKEB
Pilot-to-open check valve with standard pilotSERIES 2 / CAPACITY: 120 L/min. / CAVITY: T-2A
This valve is a pilot to open check valve. It has a non-sealed pilot, a steel seat, and is non-vented. It allows freeflow from the valve (port 2) to the load (port 1) and blocks flow in the opposite direction. Pressure at the pilot (port3) will open the valve from port 1 to port 2. Pilot pressure needed at port 3 to open the valve is directly proportionalto the load pressure at port 1. Pressure at port 2 directly opposes pilot pressure.
TECHNICAL DATAPilot Ratio 3:1Maximum Operating Pressure 350 barMaximum Valve Leakage at 110 SUS (24 cSt) 0,07 cc/min.Seal kit - Cartridge Buna: 990202007Seal kit - Cartridge EPDM: 990202014Seal kit - Cartridge Polyurethane: 990002002Seal kit - Cartridge Viton: 990202006
(X)CONTROLX Standard PilotL Manual Load Release
(C)CRACKING PRESSUREC 30 psi (2 bar)A 4 psi (0,3 bar)B 15 psi (1 bar)D 50 psi (3,5 bar)E 75 psi (5 bar)F 100 psi (7 bar)
(N)SEAL MATERIALN Buna-NE EPDMV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/CKEB
Model Code Example: CKEBXCNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 182 of 207
MODELCKGB
Pilot-to-open check valve with standard pilotSERIES 3 / CAPACITY: 240 L/min. / CAVITY: T-17A
This valve is a pilot to open check valve. It has a non-sealed pilot, a steel seat, and is non-vented. It allows freeflow from the valve (port 2) to the load (port 1) and blocks flow in the opposite direction. Pressure at the pilot (port3) will open the valve from port 1 to port 2. Pilot pressure needed at port 3 to open the valve is directly proportionalto the load pressure at port 1. Pressure at port 2 directly opposes pilot pressure.
TECHNICAL DATAPilot Ratio 3:1Maximum Operating Pressure 350 barMaximum Valve Leakage at 110 SUS (24 cSt) 0,07 cc/min.Seal kit - Cartridge Buna: 990017007Seal kit - Cartridge EPDM: 990017014Seal kit - Cartridge Polyurethane: 990017002Seal kit - Cartridge Viton: 990017006
(X)CONTROLX Standard PilotL Manual Load Release
(C)CRACKING PRESSUREC 30 psi (2 bar)A 4 psi (0,3 bar)B 15 psi (1 bar)D 50 psi (3,5 bar)E 75 psi (5 bar)F 100 psi (7 bar)
(N)SEAL MATERIALN Buna-NE EPDMV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/CKGB
Model Code Example: CKGBXCNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 183 of 207
MODELCKIB
Pilot-to-open check valve with standard pilotSERIES 4 / CAPACITY: 480 L/min. / CAVITY: T-19A
This valve is a pilot to open check valve. It has a non-sealed pilot, a steel seat, and is non-vented. It allows freeflow from the valve (port 2) to the load (port 1) and blocks flow in the opposite direction. Pressure at the pilot (port3) will open the valve from port 1 to port 2. Pilot pressure needed at port 3 to open the valve is directly proportionalto the load pressure at port 1. Pressure at port 2 directly opposes pilot pressure.
TECHNICAL DATAPilot Ratio 3:1Maximum Operating Pressure 350 barMaximum Valve Leakage at 110 SUS (24 cSt) 0,07 cc/min.Seal kit - Cartridge Buna: 990019007Seal kit - Cartridge EPDM: 990019014Seal kit - Cartridge Polyurethane: 990019002Seal kit - Cartridge Viton: 990019006
(X)CONTROLX Standard PilotL Manual Load Release
(C)CRACKING PRESSUREC 30 psi (2 bar)A 4 psi (0,3 bar)B 15 psi (1 bar)D 50 psi (3,5 bar)E 75 psi (5 bar)F 100 psi (7 bar)
(N)SEAL MATERIALN Buna-NE EPDMV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/CKIB
Model Code Example: CKIBXCNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 184 of 207
MODELCKBD
Pilot-to-open check valve with sealed pilotCAPACITY: 30 L/min. / CAVITY: T-163A
This valve is a pilot to open check valve. It has a sealed pilot, a steel seat, and is non-vented. It allows free flowfrom the valve (port 2) to the load (port 1) and blocks flow in the opposite direction. Pressure at the pilot (port 3) willopen the valve from port 1 to port 2. Pilot pressure needed at port 3 to open the valve is directly proportional to theload pressure at port 1. Pressure at port 2 directly opposes pilot pressure.
TECHNICAL DATAPilot Ratio 3:1Maximum Operating Pressure 350 barMaximum Valve Leakage at 110 SUS (24 cSt) 0,07 cc/min.Seal kit - Cartridge Buna: 990163007Seal kit - Cartridge Polyurethane: 990163002Seal kit - Cartridge Viton: 990163006
(X)CONTROLX Standard PilotL Manual Load Release
(C)CRACKING PRESSUREC 30 psi (2 bar)E 75 psi (5 bar)
(N)SEAL MATERIALN Buna-NE EPDMV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/CKBD
Model Code Example: CKBDXCNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 185 of 207
MODELCKCD
Pilot-to-open check valve with sealed pilotSERIES 1 / CAPACITY: 60 L/min. / CAVITY: T-11A
This valve is a pilot to open check valve. It has a sealed pilot, a steel seat, and is non-vented. It allows free flowfrom the valve (port 2) to the load (port 1) and blocks flow in the opposite direction. Pressure at the pilot (port 3) willopen the valve from port 1 to port 2. Pilot pressure needed at port 3 to open the valve is directly proportional to theload pressure at port 1. Pressure at port 2 directly opposes pilot pressure.
TECHNICAL DATAPilot Ratio 3:1Maximum Operating Pressure 350 barMaximum Valve Leakage at 110 SUS (24 cSt) 0,07 cc/min.Seal kit - Cartridge Buna: 990011007Seal kit - Cartridge Polyurethane: 990011002Seal kit - Cartridge Viton: 990011006
(X)CONTROLX Standard PilotL Manual Load Release
(C)CRACKING PRESSUREC 30 psi (2 bar)A 4 psi (0,3 bar)B 15 psi (1 bar)D 50 psi (3,5 bar)E 75 psi (5 bar)F 100 psi (7 bar)G 150 psi (10,5 bar)
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/CKCD
Model Code Example: CKCDXCNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 186 of 207
MODELCKED
Pilot-to-open check valve with sealed pilotSERIES 2 / CAPACITY: 120 L/min. / CAVITY: T-2A
This valve is a pilot to open check valve. It has a sealed pilot, a steel seat, and is non-vented. It allows free flowfrom the valve (port 2) to the load (port 1) and blocks flow in the opposite direction. Pressure at the pilot (port 3) willopen the valve from port 1 to port 2. Pilot pressure needed at port 3 to open the valve is directly proportional to theload pressure at port 1. Pressure at port 2 directly opposes pilot pressure.
TECHNICAL DATAPilot Ratio 3:1Maximum Operating Pressure 350 barMaximum Valve Leakage at 110 SUS (24 cSt) 0,07 cc/min.Seal kit - Cartridge Buna: 990202007Seal kit - Cartridge Polyurethane: 990002002Seal kit - Cartridge Viton: 990202006
(X)CONTROLX Standard PilotL Manual Load Release
(C)CRACKING PRESSUREC 30 psi (2 bar)A 4 psi (0,3 bar)B 15 psi (1 bar)D 50 psi (3,5 bar)E 75 psi (5 bar)F 100 psi (7 bar)
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/CKED
Model Code Example: CKEDXCNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 187 of 207
MODELCKGD
Pilot-to-open check valve with sealed pilotSERIES 3 / CAPACITY: 240 L/min. / CAVITY: T-17A
This valve is a pilot to open check valve. It has a sealed pilot, a steel seat, and is non-vented. It allows free flowfrom the valve (port 2) to the load (port 1) and blocks flow in the opposite direction. Pressure at the pilot (port 3) willopen the valve from port 1 to port 2. Pilot pressure needed at port 3 to open the valve is directly proportional to theload pressure at port 1. Pressure at port 2 directly opposes pilot pressure.
TECHNICAL DATAPilot Ratio 3:1Maximum Operating Pressure 350 barMaximum Valve Leakage at 110 SUS (24 cSt) 0,07 cc/min.Seal kit - Cartridge Buna: 990017007Seal kit - Cartridge EPDM: 990017014Seal kit - Cartridge Polyurethane: 990017002Seal kit - Cartridge Viton: 990017006
(X)CONTROLX Standard PilotL Manual Load Release
(C)CRACKING PRESSUREC 30 psi (2 bar)A 4 psi (0,3 bar)B 15 psi (1 bar)D 50 psi (3,5 bar)E 75 psi (5 bar)F 100 psi (7 bar)
(N)SEAL MATERIALN Buna-NE EPDMV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/CKGD
Model Code Example: CKGDXCNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 188 of 207
MODELCKID
Pilot-to-open check valve with sealed pilotSERIES 4 / CAPACITY: 480 L/min. / CAVITY: T-19A
This valve is a pilot to open check valve. It has a sealed pilot, a steel seat, and is non-vented. It allows free flowfrom the valve (port 2) to the load (port 1) and blocks flow in the opposite direction. Pressure at the pilot (port 3) willopen the valve from port 1 to port 2. Pilot pressure needed at port 3 to open the valve is directly proportional to theload pressure at port 1. Pressure at port 2 directly opposes pilot pressure.
TECHNICAL DATAPilot Ratio 3:1Maximum Operating Pressure 350 barMaximum Valve Leakage at 110 SUS (24 cSt) 0,07 cc/min.Seal kit - Cartridge Buna: 990019007Seal kit - Cartridge Polyurethane: 990019002Seal kit - Cartridge Viton: 990019006
(X)CONTROLX Standard PilotL Manual Load Release
(C)CRACKING PRESSUREC 30 psi (2 bar)A 4 psi (0,3 bar)B 15 psi (1 bar)D 50 psi (3,5 bar)E 75 psi (5 bar)F 100 psi (7 bar)
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/CKID
Model Code Example: CKIDXCNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 189 of 207
MODELCVCV
Vented pilot-to-open check valveSERIES 1 / CAPACITY: 60 L/min. / CAVITY: T-21A
This valve is a pilot to open check valve. It has a sealed pilot, a steel seat, and is vented. It allows free flow fromthe valve (port 2) to the load (port 1) and blocks flow in the opposite direction. Pressure at the pilot (port 3) will openthe valve from port 1 to port 2. Pilot pressure needed to open the valve is directly proportional to the load pressureat port 1. The valve is insensitive to pressure at port 2 because the spring chamber is referenced to the vent (port4).
TECHNICAL DATAPilot Ratio 3:1Maximum Operating Pressure 350 barMaximum Valve Leakage at 110 SUS (24 cSt) 0,07 cc/min.Seal kit - Cartridge Buna: 990021007Seal kit - Cartridge Polyurethane: 990021002Seal kit - Cartridge Viton: 990021006
(X)CONTROLX Standard PilotL Manual Load Release
(C)CRACKING PRESSUREC 30 psi (2 bar)A 4 psi (0,3 bar)B 15 psi (1 bar)D 50 psi (3,5 bar)E 75 psi (5 bar)F 100 psi (7 bar)
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/CVCV
Model Code Example: CVCVXCNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 190 of 207
MODELCVEV
Vented pilot-to-open check valveSERIES 2 / CAPACITY: 120 L/min. / CAVITY: T-22A
This valve is a pilot to open check valve. It has a sealed pilot, a steel seat, and is vented. It allows free flow fromthe valve (port 2) to the load (port 1) and blocks flow in the opposite direction. Pressure at the pilot (port 3) will openthe valve from port 1 to port 2. Pilot pressure needed to open the valve is directly proportional to the load pressureat port 1. The valve is insensitive to pressure at port 2 because the spring chamber is referenced to the vent (port4).
TECHNICAL DATAPilot Ratio 3:1Maximum Operating Pressure 350 barMaximum Valve Leakage at 110 SUS (24 cSt) 0,07 cc/min.Seal kit - Cartridge Buna: 990022007Seal kit - Cartridge Polyurethane: 990022002Seal kit - Cartridge Viton: 990022006
(X)CONTROLX Standard PilotL Manual Load Release
(C)CRACKING PRESSUREC 30 psi (2 bar)A 4 psi (0,3 bar)B 15 psi (1 bar)D 50 psi (3,5 bar)E 75 psi (5 bar)F 100 psi (7 bar)
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/CVEV
Model Code Example: CVEVXCNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 191 of 207
MODELCVGV
Vented pilot-to-open check valveSERIES 3 / CAPACITY: 240 L/min. / CAVITY: T-23A
This valve is a pilot to open check valve. It has a sealed pilot, a steel seat, and is vented. It allows free flow fromthe valve (port 2) to the load (port 1) and blocks flow in the opposite direction. Pressure at the pilot (port 3) will openthe valve from port 1 to port 2. Pilot pressure needed to open the valve is directly proportional to the load pressureat port 1. The valve is insensitive to pressure at port 2 because the spring chamber is referenced to the vent (port4).
TECHNICAL DATAPilot Ratio 3:1Maximum Operating Pressure 350 barMaximum Valve Leakage at 110 SUS (24 cSt) 0,07 cc/min.Seal kit - Cartridge Buna: 990023007Seal kit - Cartridge Polyurethane: 990023002Seal kit - Cartridge Viton: 990023006
(X)CONTROLX Standard PilotL Manual Load Release
(C)CRACKING PRESSUREC 30 psi (2 bar)A 4 psi (0,3 bar)B 15 psi (1 bar)D 50 psi (3,5 bar)E 75 psi (5 bar)F 100 psi (7 bar)
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/CVGV
Model Code Example: CVGVXCNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 192 of 207
MODELCVIV
Vented pilot-to-open check valveSERIES 4 / CAPACITY: 480 L/min. / CAVITY: T-24A
This valve is a pilot to open check valve. It has a sealed pilot, a steel seat, and is vented. It allows free flow fromthe valve (port 2) to the load (port 1) and blocks flow in the opposite direction. Pressure at the pilot (port 3) will openthe valve from port 1 to port 2. Pilot pressure needed to open the valve is directly proportional to the load pressureat port 1. The valve is insensitive to pressure at port 2 because the spring chamber is referenced to the vent (port4).
TECHNICAL DATAPilot Ratio 3:1Maximum Operating Pressure 350 barMaximum Valve Leakage at 110 SUS (24 cSt) 0,07 cc/min.Pilot Volume Displacement 4,✆ ccPilot Passage into Valve 2,3 mmSeal kit - Cartridge Buna: 990024007Seal kit - Cartridge EPDM: 990024014Seal kit - Cartridge Polyurethane: 990024002Seal kit - Cartridge Viton: 990024006
(X)CONTROLX Standard PilotL Manual Load Release
(C)CRACKING PRESSUREC 30 psi (2 bar)A 4 psi (0,3 bar)B 15 psi (1 bar)D 50 psi (3,5 bar)E 75 psi (5 bar)F 100 psi (7 bar)
(N)SEAL MATERIALN Buna-NE EPDMV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/CVIV
Model Code Example: CVIVXCNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 193 of 207
MODELCKCV
Vented pilot-to-open check valve - atmospherically referencedSERIES 1 / CAPACITY: 60 L/min. / CAVITY: T-11A
This valve is a pilot to open check valve. It has a sealed pilot, a steel seat, and is vented. It allows free flow fromthe valve (port 2) to the load (port 1) and blocks flow in the opposite direction. Pressure at the pilot (port 3) pilot portwill open the valve from port 1 to port 2. Pilot pressure needed to open the valve is directly proportional to the loadpressure at port 1. The valve is insensitive to pressure at port 2 because the spring chamber is referenced out theback of the hex body.
TECHNICAL DATAPilot Ratio 3:1Maximum Operating Pressure 350 barMaximum Valve Leakage at 110 SUS (24 cSt) 0,07 cc/min.Seal kit - Cartridge Buna: 990311007Seal kit - Cartridge Polyurethane: 990011002Seal kit - Cartridge Viton: 990311006
(X)CONTROLX Standard Pilot, Atmospheric VentS External 4-SAE Vent Port
(C)CRACKING PRESSUREC 30 psi (2 bar)A 4 psi (0,3 bar)B 15 psi (1 bar)D 50 psi (3,5 bar)E 75 psi (5 bar)F 100 psi (7 bar)
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/CKCV
Model Code Example: CKCVXCNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 194 of 207
MODELCKEV
Vented pilot-to-open check valve - atmospherically referencedSERIES 2 / CAPACITY: 120 L/min. / CAVITY: T-2A
This valve is a pilot to open check valve. It has a sealed pilot, a steel seat, and is vented. It allows free flow fromthe valve (port 2) to the load (port 1) and blocks flow in the opposite direction. Pressure at the pilot (port 3) pilot portwill open the valve from port 1 to port 2. Pilot pressure needed to open the valve is directly proportional to the loadpressure at port 1. The valve is insensitive to pressure at port 2 because the spring chamber is referenced out theback of the hex body.
TECHNICAL DATAPilot Ratio 3:1Maximum Operating Pressure 350 barMaximum Valve Leakage at 110 SUS (24 cSt) 0,07 cc/min.Seal kit - Cartridge Buna: 990202007Seal kit - Cartridge Polyurethane: 990002002Seal kit - Cartridge Viton: 990202006
(X)CONTROLX Standard Pilot, Atmospheric VentS External 4-SAE Vent Port
(C)CRACKING PRESSUREC 30 psi (2 bar)A 4 psi (0,3 bar)B 15 psi (1 bar)D 50 psi (3,5 bar)E 75 psi (5 bar)F 100 psi (7 bar)
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/CKEV
Model Code Example: CKEVXCNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 195 of 207
MODELCKGV
Vented pilot-to-open check valve - atmospherically referencedSERIES 3 / CAPACITY: 240 L/min. / CAVITY: T-17A
This valve is a pilot to open check valve. It has a sealed pilot, a steel seat, and is vented. It allows free flow fromthe valve (port 2) to the load (port 1) and blocks flow in the opposite direction. Pressure at the pilot (port 3) pilot portwill open the valve from port 1 to port 2. Pilot pressure needed to open the valve is directly proportional to the loadpressure at port 1. The valve is insensitive to pressure at port 2 because the spring chamber is referenced out theback of the hex body.
TECHNICAL DATAPilot Ratio 3:1Maximum Operating Pressure 350 barMaximum Valve Leakage at 110 SUS (24 cSt) 0,07 cc/min.Seal kit - Cartridge Buna: 990017007Seal kit - Cartridge Polyurethane: 990017002Seal kit - Cartridge Viton: 990017006
(X)CONTROLX Standard Pilot, Atmospheric VentS External 4-SAE Vent Port
(C)CRACKING PRESSUREC 30 psi (2 bar)A 4 psi (0,3 bar)B 15 psi (1 bar)D 50 psi (3,5 bar)E 75 psi (5 bar)F 100 psi (7 bar)
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated
snhy.com/CKGV
Model Code Example: CKGVXCNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 196 of 207
MODELCKIV
Vented pilot-to-open check valve - atmospherically referencedSERIES 4 / CAPACITY: 480 L/min. / CAVITY: T-19A
This valve is a pilot to open check valve. It has a sealed pilot, a steel seat, and is vented. It allows free flow fromthe valve (port 2) to the load (port 1) and blocks flow in the opposite direction. Pressure at the pilot (port 3) pilot portwill open the valve from port 1 to port 2. Pilot pressure needed to open the valve is directly proportional to the loadpressure at port 1. The valve is insensitive to pressure at port 2 because the spring chamber is referenced out theback of the hex body.
TECHNICAL DATAPilot Ratio 3:1Maximum Operating Pressure 350 barMaximum Valve Leakage at 110 SUS (24 cSt) 0,07 cc/min.Seal kit - Cartridge Buna: 990019007Seal kit - Cartridge Polyurethane: 990019002Seal kit - Cartridge Viton: 990019006
(X)CONTROLX Standard Pilot, Atmospheric VentS External 4-SAE Vent Port
(C)CRACKING PRESSUREC 30 psi (2 bar)A 4 psi (0,3 bar)B 15 psi (1 bar)D 50 psi (3,5 bar)E 75 psi (5 bar)F 100 psi (7 bar)
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated
snhy.com/CKIV
Model Code Example: CKIVXCNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 197 of 207
MODELCNCE
Pilot-to-open check valve with bypass orificeSERIES 1 / CAPACITY: 60 L/min. / CAVITY: T-11A
This valve is a pilot to open check valve with a bypass orifice. It incorporates a sealed pilot, a steel seat, and isnon-vented. It allows free flow from the valve (port 2) to the load (port 1) and restricts flow in the opposite direction.Pressure at the pilot (port 3) will open the valve from port 1 to port 2. The pilot pressure needed at port 3 to openthe valve is directly proportional to the load pressure at port 1. Pressure at port 2 directly opposes the pilotpressure. Note: The bypass orifice diameter is specified by the customer. See Technical Data below for theallowable orifice range.
TECHNICAL DATAPilot Ratio 3:1Maximum Operating Pressure 350 barOrifice Range 0,4 - 3,9 mmSeal kit - Cartridge Buna: 990011007Seal kit - Cartridge Polyurethane: 990011002Seal kit - Cartridge Viton: 990011006
(X)CONTROLX Not Adjustable
(C)SETTING RANGEC 30 psi (2 bar) Cracking Pressure, .016 -
.153 in. (0,4 - 3,9 mm)A 4 psi (0,3 bar) Cracking Pressure, .016
- .153 in. (0,4 - 3,9 mm)B 15 psi (1 bar) Cracking Pressure, .016 -
.153 in. (0,4 - 3,9 mm)D 50 psi (3,5 bar) Cracking Pressure,
.016 - .153 in. (0,4 - 3,9 mm)E 75 psi (5 bar) Cracking Pressure, .016 -
.153 in. (0,4 - 3,9 mm)F 100 psi (7 bar) Cracking Pressure, .016
- .153 in. (0,4 - 3,9 mm)
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/CNCE
Model Code Example: CNCEXCNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 198 of 207
MODELCNEE
Pilot-to-open check valve with bypass orificeSERIES 2 / CAPACITY: 120 L/min. / CAVITY: T-2A
This valve is a pilot to open check valve with a bypass orifice. It incorporates a sealed pilot, a steel seat, and isnon-vented. It allows free flow from the valve (port 2) to the load (port 1) and restricts flow in the opposite direction.Pressure at the pilot (port 3) will open the valve from port 1 to port 2. The pilot pressure needed at port 3 to openthe valve is directly proportional to the load pressure at port 1. Pressure at port 2 directly opposes the pilotpressure. Note: The bypass orifice diameter is specified by the customer. See Technical Data below for theallowable orifice range.
TECHNICAL DATAPilot Ratio 3:1Maximum Operating Pressure 350 barOrifice Range 0,4 - 3,4 mmSeal kit - Cartridge Buna: 990202007Seal kit - Cartridge Polyurethane: 990002002Seal kit - Cartridge Viton: 990202006
(X)CONTROLX Not Adjustable
(C)SETTING RANGEC 30 psi (2 bar) Cracking Pressure, .016 -
.135 in. (0,4 - 3,4 mm)A 4 psi (0,3 bar) Cracking Pressure, .016
- .135 in. (0,4 - 3,4 mm)B 15 psi (1 bar) Cracking Pressure, .016 -
.135 in. (0,4 - 3,4 mm)D 50 psi (3,5 bar) Cracking Pressure,
.016 - .135 in. (0,4 - 3,4 mm)E 75 psi (5 bar) Cracking Pressure, .016 -
.135 in. (0,4 - 3,4 mm)F 100 psi (7 bar) Cracking Pressure, .016
- .135 in. (0,4 - 3,4 mm)
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/CNEE
Model Code Example: CNEEXCNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 199 of 207
MODELCNGE
Pilot-to-open check valve with bypass orificeSERIES 3 / CAPACITY: 240 L/min. / CAVITY: T-17A
This valve is a pilot to open check valve with a bypass orifice. It incorporates a sealed pilot, a steel seat, and isnon-vented. It allows free flow from the valve (port 2) to the load (port 1) and restricts flow in the opposite direction.Pressure at the pilot (port 3) will open the valve from port 1 to port 2. The pilot pressure needed at port 3 to openthe valve is directly proportional to the load pressure at port 1. Pressure at port 2 directly opposes the pilotpressure. Note: The bypass orifice diameter is specified by the customer. See Technical Data below for theallowable orifice range. An 'L' control option is available to manually release the load. See Option Selection below.
TECHNICAL DATAPilot Ratio 3:1Maximum Operating Pressure 350 barOrifice Range 0,4 - 5,5 mmSeal kit - Cartridge Buna: 990017007Seal kit - Cartridge Polyurethane: 990017002Seal kit - Cartridge Viton: 990017006
(X)CONTROLX Not Adjustable
(C)SETTING RANGEC 30 psi (2 bar) Cracking Pressure, .016 -
.218 in. (0,4 - 5,5 mm)A 4 psi (0,3 bar) Cracking Pressure, .016
- .218 in. (0,4 - 5,5 mm)B 15 psi (1 bar) Cracking Pressure, .016 -
.218 in. (0,4 - 5,5 mm)D 50 psi (3,5 bar) Cracking Pressure,
.016 - .218 in. (0,4 - 5,5 mm)E 75 psi (5 bar) Cracking Pressure, .016 -
.218 in. (0,4 - 5,5 mm)F 100 psi (7 bar) Cracking Pressure, .016
- .218 in. (0,4 - 5,5 mm)
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/CNGE
Model Code Example: CNGEXCNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 200 of 207
MODELCABN
7:1 pilot ratio, vented counterbalance - valve atmospherically referencedSERIES 1 / CAPACITY: 30 L/min. / CAVITY: T-11A
3-Port Atmospherically Referenced
3-Port Atmospherically Referenced, Non-adjustable
Atmospherically-vented counterbalance valves with pilot assist are meant to control an overrunning load. The checkvalve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted reliefvalve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a ratedetermined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because the spring chamberis atmospherically referenced.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 7:1Maximum Recommended Load Pressure at Maximum Setting 215 barMaximum Setting 280 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barReseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990011007Seal kit - Cartridge Polyurethane: 990011002Seal kit - Cartridge Viton: 990011006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi w/25 psi Check (70 -
280 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/CABN
Model Code Example: CABNLHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 201 of 207
MODELCACH
10:1 pilot ratio, vented counterbalance - valve atmospherically referencedSERIES 1 / CAPACITY: 60 L/min. / CAVITY: T-11A
3-Port Atmospherically Referenced
3-Port Atmospherically Referenced, Non-adjustable
Atmospherically-vented counterbalance valves with pilot assist are meant to control an overrunning load. The checkvalve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted reliefvalve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a ratedetermined by the pilot ratio. Backpressure at port 2 does not affect the valve setting because the spring chamberis atmospherically referenced.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 10:1Maximum Recommended Load Pressure at Maximum Setting 320 barMaximum Setting 420 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 2,8 barAdjustment - Number of Counterclockwise Turns to Increase Setting 5Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990211007Seal kit - Cartridge Viton: 990211006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(G)FUNCTIONAL SETTING RANGEG 2000 - 6000 psi (140 - 420 bar), 4000
psi (280 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/AP Stainless Steel, Passivated/LH Mild Steel, Zinc-Nickel
snhy.com/CACH
Model Code Example: CACHLGNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 202 of 207
MODELCBDBX
Fixed setting, 1.5:1 pilot ratio, semi-restrictive counterbalance valveSERIES 2 / CAPACITY: 80 L/min. / CAVITY: T-2A
3-Port Non-vented, Fixed SettingFixed-setting, 3-port counterbalance valves with pilot assist function similarly to the adjustable versions except thefixed setting is pre-set to a nominal value. These fixed-setting valves are meant to control an overrunning load. Thecheck valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the reliefvalve at a rate determined by the pilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 1.5:1Maximum Recommended Load Pressure at Maximum Setting 215 barMaximum Setting 280 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Reseat >85% of settingSeal kit - Cartridge Buna: 990202007Seal kit - Cartridge Polyurethane: 990002002Seal kit - Cartridge Viton: 990202006
(N)FIXED PRESSURE RANGEN 2900 - 3500 psi (200 - 245 bar)P 2250 - 2680 psi (155 - 185 bar)
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/LH Mild Steel, Zinc-Nickel
snhy.com/CBDBX
Model Code Example: CBDBXNNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 203 of 207
MODELCBDHX
Fixed setting, 10:1 pilot ratio, restrictive counterbalance valveSERIES 2 / CAPACITY: 20 L/min. / CAVITY: T-2A
3-Port Non-vented, Fixed SettingFixed-setting, 3-port counterbalance valves with pilot assist function similarly to the adjustable versions except thefixed setting is pre-set to a nominal value. These fixed-setting valves are meant to control an overrunning load. Thecheck valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the reliefvalve at a rate determined by the pilot ratio.
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 10:1Maximum Recommended Load Pressure at Maximum Setting 270 barMaximum Setting 350 barFactory Pressure Settings Established at 30 cc/min.Seal kit - Cartridge Buna: 990202007Seal kit - Cartridge Polyurethane: 990002002Seal kit - Cartridge Viton: 990202006
(X)FIXED PRESSURE RANGEX 3500 - 4200 psi (245 - 290 bar)M 4700 - 5600 psi (325 - 390 bar)V 3200 - 3800 psi (220 - 260 bar)Z 4125 - 4900 psi (285 - 340 bar)
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/LH Mild Steel, Zinc-Nickel
snhy.com/CBDHX
Model Code Example: CBDHXXNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 204 of 207
MODELCEBA
3:1 pilot ratio, restrictive, LoadAdaptive™ counterbalance valveSERIES 1 / CAPACITY: 20 L/min. / CAVITY: T-11A
3-Port Non-vented
3-Port Non-vented, Fixed Setting
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio. The LoadAdaptive™ counterbalance valve has a higher pilot ratio when the load-induced pressure isless than the setting of the valve (is not moving yet) and when the moving load is a positive load (not overrunning).See P1-P3 diagrams under 'performance curves.` The P1 (Y axis) vs P3 (X axis) curves show the effective settingP1 of the valve for different flows depending on pilot pressure P3. Click Here for LoadAdaptive Technical Tip
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 3:1Adaptive Pilot Ratio See Performance CurvesMaximum Recommended Load Pressure at Maximum Setting 215 barMaximum Setting 280 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990011007Seal kit - Cartridge Polyurethane: 990011002Seal kit - Cartridge Viton: 990011006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(H)ADJUSTMENT RANGEH 1500 - 4000 psi w/ 25 psi check (105 -
280 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard Setting
A 1500 - 4000 psi w/ 4 psi check (105 -280 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/CEBA
Patents are pending for this product.NOTES
Model Code Example: CEBALHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 205 of 207
MODELCEBC
3:1 pilot ratio, semi-restrictive, LoadAdaptive™ counterbalance valveSERIES 1 / CAPACITY: 40 L/min. / CAVITY: T-11A
3-Port Non-vented
3-Port Non-vented, Fixed Setting
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio. The LoadAdaptive™ counterbalance valve has a higher pilot ratio when the load-induced pressure isless than the setting of the valve (is not moving yet) and when the moving load is a positive load (not overrunning).See P1-P3 diagrams under 'performance curves.` The P1 (Y axis) vs P3 (X axis) curves show the effective settingP1 of the valve for different flows depending on pilot pressure P3. Click Here for LoadAdaptive Technical Tip
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 3:1Adaptive Pilot Ratio See Performance CurvesMaximum Recommended Load Pressure at Maximum Setting 215 barMaximum Setting 280 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990011007Seal kit - Cartridge Polyurethane: 990011002Seal kit - Cartridge Viton: 990011006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(H)ADJUSTMENT RANGEH 1500 - 4000 psi w/ 25 psi check (105 -
280 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard Setting
A 1500 - 4000 psi w/ 4 psi check (105 -280 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
MATERIAL/COATINGStandard Material/Coating
/LH Mild Steel, Zinc-Nickel
snhy.com/CEBC
Patents are pending for this product.NOTES
Model Code Example: CEBCLHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 206 of 207
MODELCECA
3:1 pilot ratio, standard capacity, LoadAdaptive™ counterbalance valveSERIES 1 / CAPACITY: 60 L/min. / CAVITY: T-11A
3-Port Non-vented
3-Port Non-vented, Fixed Setting
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flowfrom the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flowfrom port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by thepilot ratio. The LoadAdaptive™ counterbalance valve has a higher pilot ratio when the load-induced pressure isless than the setting of the valve (is not moving yet) and when the moving load is a positive load (not overrunning).See P1-P3 diagrams under 'performance curves.` The P1 (Y axis) vs P3 (X axis) curves show the effective settingP1 of the valve for different flows depending on pilot pressure P3. Click Here for LoadAdaptive Technical Tip
Other names for this valve include motion control valve and over center valve.
TECHNICAL DATAPilot Ratio 3:1Adaptive Pilot Ratio See Performance CurvesMaximum Recommended Load Pressure at Maximum Setting 215 barMaximum Setting 280 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Adjustment - Number of Counterclockwise Turns to Increase Setting 3.75Reseat >85% of settingLocknut Hex Size 15 mmLocknut Torque 9 - 10 NmSeal kit - Cartridge Buna: 990011007Seal kit - Cartridge Polyurethane: 990011002Seal kit - Cartridge Viton: 990011006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(H)ADJUSTMENT RANGEH 1500 - 4000 psi w/ 25 psi check (105 -
280 bar w/ 1,7 bar Check), 3000 psi(210 bar) Standard Setting
A 1500 - 4000 psi w/ 4 psi check (105 -280 bar w/ 0,3 bar Check), 3000 psi(210 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/CECA
Patents are pending for this product.NOTES
Model Code Example: CECALHNCONFIGURATION OPTIONS
Created on 11/05/2016 c© 2016 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 207 of 207
MODELMBDN
8:1 pilot ratio, load reactive load control valveSERIES 1 / CAPACITY: 60 L/min. / CAVITY: T-11A
3-Port Non-vented
Load reactive, load control valves with pilot assist combine two valves; a check valve and a relief valve. The checkvalve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted reliefvalve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a ratedetermined by the pilot ratio.
TECHNICAL DATAPilot Ratio 8:1Maximum Recommended Load Pressure at Maximum Setting 270 barMaximum Setting 350 barFactory Pressure Settings Established at 30 cc/min.Maximum Valve Leakage at Reseat 0,3 cc/min.Check Cracking Pressure 1,7 barAdjustment - Number of Counterclockwise Turns to Increase Setting 6.5Reseat >85% of settingLocknut Hex Size 15 mmSeal kit - Cartridge Buna: 990011007Seal kit - Cartridge Polyurethane: 990011002Seal kit - Cartridge Viton: 990011006
(L)CONTROLL Standard Screw AdjustmentC Tamper Resistant - Factory Set
(H)FUNCTIONAL SETTING RANGEH 1000 - 4000 psi (70 - 280 bar), 3000 psi
(210 bar) Standard SettingJ 2000 - 5000 psi (140 - 350 bar), 3000
psi (210 bar) Standard Setting
(N)SEAL MATERIALN Buna-NV Viton
snhy.com/MBDN
Model Code Example: MBDNLHNCONFIGURATION OPTIONS
www.sunhydraulics.com Rev. 11Feb15 | © 2015 Sun Hydraulics Corporation
Corporate Headquarters
1500 West University Parkway
Sarasota, FL 34243 U.S.A.
Phone: 941.362.1200
Sun Hydraulics Limited
Wheler Road
Coventry CV3 4LA
England
Ph: +44-2476-217-400
Sun Hydraulics Korea Corp.
92 Hogupo-ro
Namdong-gu
Incheon 405-818
Korea
Ph: +82-32-813-1350
Sun Hydraulik GmbH
Brüsseler Allee 2
D-41812 Erkelenz
Germany
Ph: +49-2431-8091-0
Sun Hydraulics China Co. Ltd
Hong Kong New World Tower
47th Floor
300, Huaihai Zhong Road
Shanghai 200021
P.R.China
Ph: +86-21-5116-2862
Sun Hydraulics Corporation
55 rue Fragonard
Résidence Rambouillet - Appt A-42
33520 Bruges
France
Ph: +33-673063371
Sun Hydraulics (India)
No. 48 ‘Regent Prime’
Unit No. 306, Level 3
Whiteield Main Road, Whiteield, Bangalore - 560 066India
Ph: +0091-80-28456325