Page 1: LMI Electronic Metering Pumps. Pump Selection Set-up and Installation Maintenance Basic Pump Operation LMI Metering Pumps

LMI Electronic Metering Pumps

LMI Electronic Metering Pumps

Page 2: LMI Electronic Metering Pumps. Pump Selection Set-up and Installation Maintenance Basic Pump Operation LMI Metering Pumps

Pump SelectionPump Selection

Set-up Set-up and Installationand InstallationMaintenanceMaintenance

Basic Pump OperationBasic Pump Operation

LMI Metering

Pumps

Page 3: LMI Electronic Metering Pumps. Pump Selection Set-up and Installation Maintenance Basic Pump Operation LMI Metering Pumps

Basic Pump OperationBasic Pump Operation

•Discharge StrokeDischarge Stroke

•Suction StrokeSuction Stroke

•ControlsControls

•AdvantagesAdvantages

Page 4: LMI Electronic Metering Pumps. Pump Selection Set-up and Installation Maintenance Basic Pump Operation LMI Metering Pumps

• Coil is energized, Coil is energized, becoming magneticbecoming magnetic

• Armature and Armature and shaft are pulled shaft are pulled towards liquid endtowards liquid end

• Liquifram™ Liquifram™ (attached to shaft) (attached to shaft) is pushed into headis pushed into head

Discharge StrokeDischarge StrokeB

asic

Pu

mp

Op

erat

ion

Bas

ic P

um

p O

per

atio

n

Page 5: LMI Electronic Metering Pumps. Pump Selection Set-up and Installation Maintenance Basic Pump Operation LMI Metering Pumps

During the discharge stroke, the suction balls seats,

preventing solution from going back to the solution tank. The solution is forced through the

discharge valve.

Page 6: LMI Electronic Metering Pumps. Pump Selection Set-up and Installation Maintenance Basic Pump Operation LMI Metering Pumps

• Coil is de-Coil is de-energizedenergized

• Springs return Springs return the armature the armature and shaftand shaft

• Liquifram™ is Liquifram™ is pulled back, pulled back, creating vacuumcreating vacuum

Suction StrokeSuction StrokeB

asic

Pu

mp

Op

erat

ion

Bas

ic P

um

p O

per

atio

n

Page 7: LMI Electronic Metering Pumps. Pump Selection Set-up and Installation Maintenance Basic Pump Operation LMI Metering Pumps

During the suction stroke, a vacuum is created.

The head cavity fills as the Liquifram returns.

The suction ball rises while the discharge ball seats.

Page 8: LMI Electronic Metering Pumps. Pump Selection Set-up and Installation Maintenance Basic Pump Operation LMI Metering Pumps

ControlsB

asic

Pu

mp

Op

erat

ion

Bas

ic P

um

p O

per

atio

n

Speed Knob

Stroke Length Control Knob

Pressure control

4-Pin Input Jack

Power Cord

Page 9: LMI Electronic Metering Pumps. Pump Selection Set-up and Installation Maintenance Basic Pump Operation LMI Metering Pumps

• NoNo rotating motor and camrotating motor and cam

• Only one, permanently lubricated, Only one, permanently lubricated, moving partmoving part

• Totally enclosed, chemically Totally enclosed, chemically resistantresistant

• Easy and inexpensive to externally Easy and inexpensive to externally controlcontrol

Advantages of Electronic Pumps

Bas

ic P

um

p O

per

atio

nB

asic

Pu

mp

Op

erat

ion

Page 10: LMI Electronic Metering Pumps. Pump Selection Set-up and Installation Maintenance Basic Pump Operation LMI Metering Pumps

Pump SelectionPump Selection

• Numbering SystemNumbering System

• DriveDrive

• Liquid EndLiquid End

Page 11: LMI Electronic Metering Pumps. Pump Selection Set-up and Installation Maintenance Basic Pump Operation LMI Metering Pumps

LMI Pump model numbers consist of LMI Pump model numbers consist of two main components:two main components:

AA941 - 358TI

Drive Liquid EndPu

mp

Sel

ecti

onP

um

p S

elec

tion

Numbering SystemNumbering System

Page 12: LMI Electronic Metering Pumps. Pump Selection Set-up and Installation Maintenance Basic Pump Operation LMI Metering Pumps

AA 9 4 1AA 9 4 1

Output Code

Control Code

The Series

Voltage code

Pu

mp

Sel

ecti

onP

um

p S

elec

tion

The DriveThe Drive

Page 13: LMI Electronic Metering Pumps. Pump Selection Set-up and Installation Maintenance Basic Pump Operation LMI Metering Pumps

AAAA141

Note:Note: Pumps within a series operate at maximum pressure or maximum output. The higher the output, the lower the pressure capabilities within each series.

Pu

mp

Sel

ecti

onP

um

p S

elec

tion

The Series: The Series:

AA Series: 2 GPH, 250 PSI (7.6 l/h, 17.3 bar)

B Series: 7 GPH, 150 PSI (26.5 l/h, 10.3 bar)

C Series: 25 GPH, 300 PSI (95 l/h, 20.7 bar)

E7 Series: 20 GPH, 300 PSI (76 l/h, 20.7 bar)

P Series: 2 GPH, 250 PSI (7.6 l/h, 17.3 bar)

G Series: 300 GPH, 175 PSI (1136 l/h, 12 bar)

HH Series: 0.14 GPH, 1000 PSI (0.5 l/h, 70 bar)

J5 Series: 2GPH, 140 PSI ( 7.6 l/h, 9.7 bar)

Page 14: LMI Electronic Metering Pumps. Pump Selection Set-up and Installation Maintenance Basic Pump Operation LMI Metering Pumps

AAAA114141P

um

p S

elec

tion

Pu

mp

Sel

ecti

onControl Codes: Control Codes:

• Control code Control code 00– Manual stroke length control, fixed speedManual stroke length control, fixed speed

• Control code Control code 11– Manual stroke length and speed controlManual stroke length and speed control

• Control code Control code 77– Manual stroke length & speed control with external control Manual stroke length & speed control with external control

optionoption

• Control code Control code 99– Microprocessor control with LCD; external control by Microprocessor control with LCD; external control by

milliAmp or digital ( pulse) inputmilliAmp or digital ( pulse) input

Page 15: LMI Electronic Metering Pumps. Pump Selection Set-up and Installation Maintenance Basic Pump Operation LMI Metering Pumps

• MP-100• MP-400D• MP-500M• Pulse Transmitter• RFP Remote

Flowmeter Pulser• FC Flowmeter

Contactor

Methods of Triggering

Pu

mp

Sel

ecti

onP

um

p S

elec

tion

Series AA7/B7/C7/P7Series AA7/B7/C7/P7

Page 16: LMI Electronic Metering Pumps. Pump Selection Set-up and Installation Maintenance Basic Pump Operation LMI Metering Pumps

• 4-20 mA DC• High frequency

pulses• Low frequency

pulses• Pulse Transmitter• RFP Flowmeter• FC FlowmeterP

um

p S

elec

tion

Pu

mp

Sel

ecti

onSeries AA9/B9/C9/H9Series AA9/B9/C9/H9

Methods of Triggering

Page 17: LMI Electronic Metering Pumps. Pump Selection Set-up and Installation Maintenance Basic Pump Operation LMI Metering Pumps

• MP-100• MP-400D• MP-500M• Pulse transmitter• RFP Remote

Flowmeter Pulser• FC Flowmeter

Contactor

Methods of Triggering

Pu

mp

Sel

ecti

onP

um

p S

elec

tion

Series E7: Series E7: Explosion ProofExplosion Proof

Note: Note: Accessories Accessories

are NOT are NOT explosion explosion

proofproof

Page 18: LMI Electronic Metering Pumps. Pump Selection Set-up and Installation Maintenance Basic Pump Operation LMI Metering Pumps

The output code determines output The output code determines output and pressure capability within a and pressure capability within a pump series. Select the proper pump series. Select the proper output code using the LMI Pump output code using the LMI Pump Selection Guide.Selection Guide.

AAAA114411P

um

p S

elec

tion

Pu

mp

Sel

ecti

onOutput Codes: Output Codes:

Page 19: LMI Electronic Metering Pumps. Pump Selection Set-up and Installation Maintenance Basic Pump Operation LMI Metering Pumps

Voltage code 1 = 120 VAC U.S. PlugVoltage code 1 = 120 VAC U.S. Plug

Voltage code 2 = 240 VAC U.S. PlugVoltage code 2 = 240 VAC U.S. Plug

Voltage code 3 = 220-240 VAC DIN PlugVoltage code 3 = 220-240 VAC DIN Plug

Voltage code 5 = 240-250 VAC UK PlugVoltage code 5 = 240-250 VAC UK Plug

Voltage code 6 = 240-250 Aust/NZ PlugVoltage code 6 = 240-250 Aust/NZ Plug

Voltage code 7 = 220 VAC Swiss PlugVoltage code 7 = 220 VAC Swiss Plug

AAAA141411P

um

p S

elec

tion

Pu

mp

Sel

ecti

onVoltage Codes: Voltage Codes:

Page 20: LMI Electronic Metering Pumps. Pump Selection Set-up and Installation Maintenance Basic Pump Operation LMI Metering Pumps

Pu

mp

Sel

ecti

onP

um

p S

elec

tion

Liquid EndLiquid End

• Select a liquid end compatible with the pump drive using the Pump Selection Guide.

• Use the Chemical Resistance Chart to select a suitable liquid end material.

Page 21: LMI Electronic Metering Pumps. Pump Selection Set-up and Installation Maintenance Basic Pump Operation LMI Metering Pumps

3 5 8 T I

LiquiPro™ Series

Materials

Valve code

Tubing code

Head/tubing size

Pu

mp

Sel

ecti

onP

um

p S

elec

tion

Liquid EndLiquid End

Page 22: LMI Electronic Metering Pumps. Pump Selection Set-up and Installation Maintenance Basic Pump Operation LMI Metering Pumps

Advantages• Cartridge valve systems eliminates distortion of seal

rings due to overtightening

• Better volumetric efficiency

• Superior priming performance

• Better seal to prevent leaks

Pu

mp

Sel

ecti

onP

um

p S

elec

tion

LiquiPro™ Series: 3358TI58TI

33 = Molded= Molded

4 = Machined4 = Machined

Page 23: LMI Electronic Metering Pumps. Pump Selection Set-up and Installation Maintenance Basic Pump Operation LMI Metering Pumps

Pu

mp

Sel

ecti

onP

um

p S

elec

tion

Head/Tubing Size:Head/Tubing Size: 335858TITI

• 5 = 0.55 = 0.5

• 9 = 0.99 = 0.9

• 6 = 1.86 = 1.8

• 1 = 3.01 = 3.0

Page 24: LMI Electronic Metering Pumps. Pump Selection Set-up and Installation Maintenance Basic Pump Operation LMI Metering Pumps

• 8 = PVC8 = PVC

• 0 = Acrylic0 = Acrylic

• 2 = PVDF / Polyprel2 = PVDF / PolyprelTMTM

• 3 = PDVF / PTFE3 = PDVF / PTFE

Materials:Materials: 358TI358TIP

um

p S

elec

tion

Pu

mp

Sel

ecti

on

Page 25: LMI Electronic Metering Pumps. Pump Selection Set-up and Installation Maintenance Basic Pump Operation LMI Metering Pumps

Pu

mp

Sel

ecti

onP

um

p S

elec

tion

Valve Code:Valve Code: 358358TTII

• T = Three Function Valve (3FV)

• S = Four Function Valve (4FV)

• N = No Accessory Valve, Fitting Only

• H = AutoPrime (AV) + Four Function Valve (4FV)

Page 26: LMI Electronic Metering Pumps. Pump Selection Set-up and Installation Maintenance Basic Pump Operation LMI Metering Pumps

Set-up and InstallationSet-up and Installation

• Box ContentsBox Contents

• Installation TipsInstallation Tips

• PrimingPriming

• CalibrationCalibration

Page 27: LMI Electronic Metering Pumps. Pump Selection Set-up and Installation Maintenance Basic Pump Operation LMI Metering Pumps

• PumpPump

• 16 feet (5m) of tubing16 feet (5m) of tubing

• Foot valveFoot valve

• Injection check valveInjection check valve

• Discharge valveDischarge valve(4FV, B4FV, 3FV, 4FV+AV or straight fitting)(4FV, B4FV, 3FV, 4FV+AV or straight fitting)

• Instruction manualsInstruction manuals

• Ceramic weightCeramic weight

Set

-up

an

d I

nst

alla

tion

Set

-up

an

d I

nst

alla

tion

Box ContentsBox Contents

Page 28: LMI Electronic Metering Pumps. Pump Selection Set-up and Installation Maintenance Basic Pump Operation LMI Metering Pumps

• Always wear protective clothing

• Pump is pre-primed with water

• Verify solution compatibility

• Do not reduce tubing connection

• Do not use Teflon® tape

• Adhere to local plumbing & electrical codes

• Use grounded receptacle

Set

-up

an

d I

nst

alla

tion

Set

-up

an

d I

nst

alla

tion

Pre-Installation Pre-Installation PrecautionsPrecautions

Page 29: LMI Electronic Metering Pumps. Pump Selection Set-up and Installation Maintenance Basic Pump Operation LMI Metering Pumps

Set

-up

an

d I

nst

alla

tion

Set

-up

an

d I

nst

alla

tion

Suction LiftSuction Lift• Injection check valve

should be vertical (pointing up)

• Foot valve must be vertical• Suction tubing should be

straight; no curves or bends

• Maximum suction lift 5 feet (1.5m)

Page 30: LMI Electronic Metering Pumps. Pump Selection Set-up and Installation Maintenance Basic Pump Operation LMI Metering Pumps

Set

-up

an

d I

nst

alla

tion

Set

-up

an

d I

nst

alla

tion

Flooded SuctionFlooded Suction• True vs. false flooded suctionTrue vs. false flooded suction

• Day tanks-safety issuesDay tanks-safety issues

• Back pressure valvesBack pressure valves

Page 31: LMI Electronic Metering Pumps. Pump Selection Set-up and Installation Maintenance Basic Pump Operation LMI Metering Pumps

• Determine required pump outputDetermine required pump output

• Determine percent of pump outputDetermine percent of pump output

• Determine stroke and speed settingsDetermine stroke and speed settings

Set

-up

an

d I

nst

alla

tion

Set

-up

an

d I

nst

alla

tion

Determining Determining Pump OutputPump Output

Page 32: LMI Electronic Metering Pumps. Pump Selection Set-up and Installation Maintenance Basic Pump Operation LMI Metering Pumps

Desired PPM x GPM of FlowDesired PPM x GPM of Flow

% Concentration of Chemical% Concentration of Chemical x ..006006

= Required Pump Output in GPHRequired Pump Output in GPH

Set

-up

an

d I

nst

alla

tion

Set

-up

an

d I

nst

alla

tion

Calculating Calculating Required OutputRequired Output

Page 33: LMI Electronic Metering Pumps. Pump Selection Set-up and Installation Maintenance Basic Pump Operation LMI Metering Pumps

Required Pump OutputRequired Pump Output

Maximum Output of PumpMaximum Output of Pump

% Output Required from Pump% Output Required from Pump

Set

-up

an

d I

nst

alla

tion

Set

-up

an

d I

nst

alla

tion

Calculating Calculating Output PercentageOutput Percentage

=

Page 34: LMI Electronic Metering Pumps. Pump Selection Set-up and Installation Maintenance Basic Pump Operation LMI Metering Pumps

% Output Required from Pump% Output Required from Pump

% Speed and % Stroke% Speed and % Stroke

Set

-up

an

d I

nst

alla

tion

Set

-up

an

d I

nst

alla

tion

Calculating Calculating % Speed / % Stroke% Speed / % Stroke

=

Page 35: LMI Electronic Metering Pumps. Pump Selection Set-up and Installation Maintenance Basic Pump Operation LMI Metering Pumps

• Output adjustment= 80% speed, Output adjustment= 80% speed, 100% stroke100% stroke

• Vent pump to atmosphere via Vent pump to atmosphere via 3FV or 4FV3FV or 4FV

• Vent tubing to supply tankVent tubing to supply tank

LMI pumps are pre-primed with LMI pumps are pre-primed with water to assist in priming:water to assist in priming:

Set

-up

an

d I

nst

alla

tion

Set

-up

an

d I

nst

alla

tion

PrimingPriming

Page 36: LMI Electronic Metering Pumps. Pump Selection Set-up and Installation Maintenance Basic Pump Operation LMI Metering Pumps

• Verify that the pump is primedVerify that the pump is primed

• Use a graduated cylinder on Use a graduated cylinder on suction side of pumpsuction side of pump

• Run 60 second testRun 60 second test

• Adjust pump as necessaryAdjust pump as necessary

LMI Pumps should be calibrated during installation or whenever the output is adjusted

Set

-up

an

d I

nst

alla

tion

Set

-up

an

d I

nst

alla

tion

CalibrationCalibration

Page 37: LMI Electronic Metering Pumps. Pump Selection Set-up and Installation Maintenance Basic Pump Operation LMI Metering Pumps

MaintenanceMaintenance

• RPM Pro Pac™ KitsRPM Pro Pac™ Kits

• Liquifram™ ReplacementLiquifram™ Replacement

Page 38: LMI Electronic Metering Pumps. Pump Selection Set-up and Installation Maintenance Basic Pump Operation LMI Metering Pumps

• Cartridge valves Cartridge valves (balls/seal rings)(balls/seal rings)

• Liquifram™Liquifram™

• Clamp ringsClamp rings

Preventative Preventative MaintenanceMaintenance

Spare parts should be replaced annually including:

• FerrulesFerrules

• Head screwsHead screws

• Shaft sealShaft sealMai

nte

nan

ceM

ain

ten

ance

Page 39: LMI Electronic Metering Pumps. Pump Selection Set-up and Installation Maintenance Basic Pump Operation LMI Metering Pumps

• Liquifram™

• Clamp rings / Ferrules

• Cartridge valves

• Head Screws• Instructions

• Shaft sealMai

nte

nan

ceM

ain

ten

ance

RPM Pro Pac™ KitsRPM Pro Pac™ Kits