list prices for lattner boilers & accessorieslattner.com/userfiles/literature/lattner prices...

34
Copies of Vertical Steam Boilers and Options Copies of Scotch Marine Boiler Prices and Options Copies of Gas Steam Room Package Prices Copies of Electric Steam Room Package Prices Copies of Horizontal Electric Boiler Prices and Options Copies of Space Saver Electric Boiler Prices and Options Copies of Cabinet Style Electric Boiler Prices and Options Copies of Simplex Condensate Return System Prices Copies of Duplex Condensate Return System Prices Copies of Blowdown Separator System Prices Copies of Water Softener and Chemical Feed System Prices Copies of State Codes Thank you for your continued efforts on Lattner's behalf. Lattner Boiler Company LIST PRICES FOR LATTNER BOILERS If additional copies of the enclosed material are desired, please clip off this section, fill in the desired information, and return it to Lattner Boiler Company, P.O. Box 1527, Cedar Rapids, IA 52406. You may also fax this information to 319-366- 0770 or email this information to [email protected]. New prices will become effective on March 1, 2013. Orders placed on the telephone, by fax, by email, or postmarked on or before February 28, 2013, requesting shipment within 60 days, will be honored at August 1, 2011 prices. Enclosed are new price sheets for our boilers, condensate returns systems, blowdown separators, and accessories. These price sheets supersede all previous price sheets. & ACCESSORIES Effective: March 1, 2013 To our dealers and representatives: AVAILABLE FOR DOWNLOAD AT WWW.LATTNERBOILER.COM Unprecedented increases in such areas as energy, ASME quality steel, copper, and O.E.M. purchased parts have made this price adjustment necessary. State: Zip: Telephone: Email: Name: Company: Street: City:

Upload: vokhuong

Post on 16-Mar-2018

226 views

Category:

Documents


5 download

TRANSCRIPT

Page 1: LIST PRICES FOR LATTNER BOILERS & ACCESSORIESlattner.com/userfiles/literature/lattner prices march 2013.pdf · Lattner Boiler Company Vertical Steam Boiler Options March 1st, 2013

Copies of Vertical Steam Boilers and OptionsCopies of Scotch Marine Boiler Prices and OptionsCopies of Gas Steam Room Package PricesCopies of Electric Steam Room Package PricesCopies of Horizontal Electric Boiler Prices and OptionsCopies of Space Saver Electric Boiler Prices and OptionsCopies of Cabinet Style Electric Boiler Prices and OptionsCopies of Simplex Condensate Return System PricesCopies of Duplex Condensate Return System PricesCopies of Blowdown Separator System PricesCopies of Water Softener and Chemical Feed System PricesCopies of State Codes

Thank you for your continued efforts on Lattner's behalf.

Lattner Boiler Company

LIST PRICES FOR LATTNER BOILERS

If additional copies of the enclosed material are desired, please clip off this section, fill in the desired information, and return it to Lattner Boiler Company, P.O. Box 1527, Cedar Rapids, IA 52406. You may also fax this information to 319-366-0770 or email this information to [email protected].

New prices will become effective on March 1, 2013.

Orders placed on the telephone, by fax, by email, or postmarked on or before February 28, 2013, requesting shipment within 60 days, will be honored at August 1, 2011 prices.

Enclosed are new price sheets for our boilers, condensate returns systems, blowdown separators, and accessories. These price sheets supersede all previous price sheets.

& ACCESSORIES

Effective: March 1, 2013

To our dealers and representatives:

AVAILABLE FOR DOWNLOAD AT WWW.LATTNERBOILER.COM

Unprecedented increases in such areas as energy, ASME quality steel, copper, and O.E.M. purchased parts have made this price adjustment necessary.

State:

Zip:

Telephone:

Email:

Name:

Company:

Street:

City:

Page 2: LIST PRICES FOR LATTNER BOILERS & ACCESSORIESlattner.com/userfiles/literature/lattner prices march 2013.pdf · Lattner Boiler Company Vertical Steam Boiler Options March 1st, 2013

INDEX

Vertical Tubeless Steam Boilers Page 3Vertical Tubeless Steam Boiler Options Page 4Scotch Marine Vessels (Less Burners) Page 6Scotch Marine Burners (Natural Gas) Page 7Scotch Marine Burners (#2 Oil) Page 8Scotch Marine Burners (Dual Fuel) Page 9Scotch Marine Boiler Options (10 to 50 HP) Page 10Scotch Marine Boiler Options (60 to 200 HP) Page 11Steam Room Packages (Natural Gas) Page 12Steam Room Packages (Electric) Page 13Horizontal Electric Steam Boilers Page 14Space Saver Electric Hot Water Boilers Page 15Space Saver Electric Hot Water Boiler Options Page 17Cabinet Style Electric Hot Water Boilers (480v) Page 19Cabinet Style Electric Hot Water Boilers (240v) Page 21Cabinet Style Electric Hot Water Boilers (208v) Page 22Cabinet Style Electric Steam Boilers (480v) Page 23Cabinet Style Electric Steam Boilers (240v) Page 25Cabinet Style Electric Steam Boilers (208v) Page 26Cabinet Style Electric Boiler Options Page 27Simplex Condensate Return / Feed Water Systems Page 28Duplex Condensate Return / Feed Water Systems Page 29Blowdown Separators Page 30Water Softeners and Chemical Feed Systems Page 31State Code Requirments Page 32Warranty Page 33Terms and Conditions Page 34

2

Page 3: LIST PRICES FOR LATTNER BOILERS & ACCESSORIESlattner.com/userfiles/literature/lattner prices march 2013.pdf · Lattner Boiler Company Vertical Steam Boiler Options March 1st, 2013

Lattner Boiler CompanyVertical Tubeless Steam Boilers

March 1st, 2013Bulletin: SB202R

Lattner Boiler CompanyP.O. Box 15271411 9th St. SWCedar Rapids, IA 52406

Telephone: (800) 345-1527Fax: (319) 366-0770

Email: [email protected]: www.lattnerboiler.com

Vertical Boiler: 1.5 3 5 7 9.5 10 15 20 25 30 40 50H.E.1 $5,770 $7,470 $8,410 $11,640 $12,630 $12,810 $13,900 $16,920H.E. Low-NOx (Sub 55 PPM) $9,700 $10,520 $14,350 $15,060WLF $15,180 $15,180 $15,750 $18,500 $21,260 $24,640 $29,960 $34,330WLF Low-NOx (Sub 30 PPM) $18,480 $18,480 $19,640 $22,590 $25,540 $27,970 $34,110 $37,740G5 Low-NOx (Sub 20 PPM) $22,170 $22,170 $22,390 $23,930 $26,600 $28,360 $36,840 $39,950

Notes:

Boiler Size (HP) / Price (USD)

Steam boiler package includes: UL or ETL approved package, natural or LP gas burner assembly, flame programmer with electronic ignition, operating pressure control, high pressure limit w/manual reset, float-type level control w/primary low water cut-off, auxiliary probe-type low water cut-off w/manual reset, drain valves for water column level control, safety relief valve, steam pressure gauge, water gauge set w/sight glass protector. Standard ASME Section I design pressure 150 psi.

LATTNER IS NOT RESPONSIBLE FOR DETERMINING CITY, COUNTY, STATE, FEDERAL, OR INSURANCE CODE REQUIREMENTS. IT IS THE SOLE RESPONSIBILITY OF THE REPRESENTATIVE, DISTRIBUTOR, AND/OR CUSTOMER TO DETERMINE APPLICABLE BOILER CODES.

ALL PRICES ARE F.O.B. FACTORY AND SUBJECT TO CHANGE WITHOUT NOTICE.

ALL BOILERS MUST BE STARTED BY QUALIFIED PERSONNEL USING COMBUSTION ANALYZER. WARRANTY VALIDATION AND START-UP REPORT MUST BE RETURNED TO LATTNER FOLLOWING START-UP.

ENGINEERING CHANGES, INCLUDING WIRING DIAGRAM AND EQUIPMENT SUPPLY CHANGES, MADE AFTER SUBMITTAL APPROVAL WILL BE INVOICED AT $90 (NET) PER HOUR.

1) 1.5, 3, 5, and 7 HP H.E. boilers are designed to 100 PSI. Call factory for higher design pressure construction.

3

Page 4: LIST PRICES FOR LATTNER BOILERS & ACCESSORIESlattner.com/userfiles/literature/lattner prices march 2013.pdf · Lattner Boiler Company Vertical Steam Boiler Options March 1st, 2013

Lattner Boiler CompanyVertical Steam Boiler Options

March 1st, 2013Bulletin: SB202R

Lattner Boiler CompanyP.O. Box 15271411 9th St. SWCedar Rapids, IA 52406

Telephone: (800) 345-1527Fax: (319) 366-0770

Email: [email protected]: www.lattnerboiler.com

Burner Options: 1.5 3 5 7 9.5 10 15 20 25 30 40 50On / Off Burner Operation std. std. std. std. std. std. std. std. std.Low Fire Start Burner Operation $680 $680 $580 $580 std. std. std.Full Modulation Burner Operation $2,790 $1,900 $2,260 $2,260Step Down Gas Pressure Regulator $560 $560 $560 $560 $560 $560 $560 $720 $720 $800 $800 $900Direct Vent $230 $230 $230 $230 $230 $230 $230Air Inlet Silencer (90 dba) $390 $390 $390 $390 $390 $390 $550

Electrical Options: 1.5 3 5 7 9.5 10 15 20 25 30 40 50Honeywell Digital Display Module $530 $530 $530 $530 $530 $530 $5303 Phase/Alternate Voltages $540 $540 $540 $540 $540 $540 $540Additional Dry Contacts (per set) $220 $220 $220 $220 $220 $220 $220 $220 $220 $220 $220 $220

Trim & Blowdown Options: 1.5 3 5 7 9.5 10 15 20 25 30 40 50Valve Package1 std. std. std. std. std. std. std. std. std. std. $1,380 $1,450ASME Hydrotest w/P-6 Data Report2 $250 $250 $250 $250 $250 $250 $250 $250 $250 $250 $250 $250Stainless Steel Jacket $550 $620 $700 $790 $890 $1,000 $1,120 $1,260 $1,420 $1,600 $1,800 $2,020Low Water Level Alarm (LWL-1) $250 $250 $250 $250 $250 $250 $250 $250 $250 $250 $250 $250High Water Level Alarm (HWL-1) $460 $460 $460 $460 $460 $460 $460 $460 $460 $460 $460 $460Float Type Auxiliary Low Water Cut-O $840 $840 $840 $840 $840 $840 $840 $840 $840 $840 $840 $840Night Operation Pressure Switch $280 $280 $280 $280 $280 $280 $280 $280 $280 $280 $280 $280Automatic Bottom Blowdown $1,240 $1,240 $1,240 $1,240 $1,240 $1,240 $1,240 $1,240 $1,240 $1,320 $1,320 $1,320Manual Surface Blowoff $230 $230 $230 $230 $230 $230 $230 $230 $230 $230 $230 $230Automatic Surface Blowoff $1,100 $1,100 $1,100 $1,100 $1,100 $1,100 $1,100 $1,100 $1,100 $1,100 $1,100 $1,100TDS/Conductivity Surface Blowoff $3,900 $3,900 $3,900 $3,900 $3,900 $3,900 $3,900 $3,900 $3,900 $3,900 $3,900 $3,900Stack Thermometer $150 $150 $150 $150 $150 $150 $150 $150 $150 $150 $150 $150Barometric Damper $220 $220 $220 $220 $220 $280 $370 $390

Skid Mounting Options: 1.5 3 5 7 9.5 10 15 20 25 30 40 50Skid Package A3 $2,950 $3,270 $3,630 $4,020 $4,460 $4,460 $4,540 $5,150 $6,260 $6,260 $8,780 $8,780Skid Package B4 $3,910 $4,340 $4,810 $5,340 $5,930 $5,930 $6,010 $6,640 $7,780 $7,780 $10,330 $10,330Single Point Electrical Connection $1,170 $1,170 $1,170 $1,170 $1,170 $1,170 $1,170 $1,170 $1,170 $1,170 $1,640 $2,290

Other Options: 1.5 3 5 7 9.5 10 15 20 25 30 40 50Additional Manuals (each)5 $30 $30 $30 $30 $30 $30 $30 $30 $30 $30 $30 $30Additional Submittals (each)6 $15 $15 $15 $15 $15 $15 $15 $15 $15 $15 $15 $15Factory Start-Up7 $1,400 $1,400 $1,400 $1,400 $1,400 $1,400 $1,400 $1,400 $1,400 $1,400 $1,400 $1,400

Notes:

Boiler Size (HP) / Price (USD)

1) Valve package includes main steam stop, feedwater stop, feedwater check, slow open blowdown, and quick open blowdown valves.

4

Page 5: LIST PRICES FOR LATTNER BOILERS & ACCESSORIESlattner.com/userfiles/literature/lattner prices march 2013.pdf · Lattner Boiler Company Vertical Steam Boiler Options March 1st, 2013

Lattner Boiler CompanyVertical Steam Boiler Options

March 1st, 2013Bulletin: SB202R

Lattner Boiler CompanyP.O. Box 15271411 9th St. SWCedar Rapids, IA 52406

Telephone: (800) 345-1527Fax: (319) 366-0770

Email: [email protected]: www.lattnerboiler.com

ALL PRICES ARE F.O.B. FACTORY AND SUBJECT TO CHANGE WITHOUT NOTICE.

7) Boiler start-up by a factory authorized representative may be requested for a net cost of $1400 per day plus travel and expenses. Boiler start-up cannot be scheduled until start-up request has been returned to Lattner.

4) Skid package B includes wiring, piping, and mounting for boiler, blowdown tank, return system, water softener, and chemical feed system. PRICE DOES NOT INCLUDE BOILER, BLOWDOWN TANK, RETURN SYSTEM, WATER SOFTENER, OR CHEMICAL FEED.5) One instruction manual will be provided with the boiler no charge at the time of the boiler order. One additional manual will be provided no charge at the time of the order if requested. Additional manuals or manuals requested after the boiler is shipped will be invoiced at $30 each.6) Two sets of submittals will be provided with the boiler no charge at the time of the boiler order. One additional digital (email) set of submittals will be provided no charge at the time of the order if requested. Additional submittals or submittals requested after the boiler is shipped will be invoiced at $15 each.

2) ASME piping and hydrostatic test w/P-6 data report is required in AZ, CO, IA, IN, KS, KY, NE, OH, VA, WI.

3) Skid package A includes wiring, piping, and mounting for boiler, blowdown tank, and return system. PRICE DOES NOT INCLUDE BOILER, BLOWDOWN TANK, OR RETURN SYSTEM.

5

Page 6: LIST PRICES FOR LATTNER BOILERS & ACCESSORIESlattner.com/userfiles/literature/lattner prices march 2013.pdf · Lattner Boiler Company Vertical Steam Boiler Options March 1st, 2013

Lattner Boiler CompanyDry Back Scotch Marine Vessels (Less Burners)

March 1st, 2013Bulletin: SB121

Lattner Boiler CompanyP.O. Box 15271411 9th St. SWCedar Rapids, IA 52406

Telephone: (800) 345-1527Fax: (319) 366-0770

Email: [email protected]: www.lattnerboiler.com

Vessels: 10 15 20 25 30 40 50Steam, 15 PSI (Section IV) $22,420 $22,420 $26,770 $27,040 $31,510 $31,610 $39,890Steam, 150 PSI (Section I) $23,600 $23,600 $28,450 $28,720 $33,660 $33,740 $42,940Steam, 200 PSI $26,560 $26,560 $32,610 $32,880 $39,020 $39,090 $50,540Hot Water, 160 PSI $23,000 $23,000 $27,610 $27,880 $32,580 $32,670 $41,410

Vessels: 60 80 100 125 150 200 250Steam, 15 PSI (Section IV) $40,160 $50,560 $59,830 $66,980 $73,060 $88,300 $96,720Steam, 150 PSI (Section I) $43,210 $54,750 $65,010 $72,850 $79,520 $96,380 $105,740Steam, 200 PSI $50,810 $65,200 $77,950 $87,530 $95,670 $116,590 $128,300Hot Water, 160 PSI $41,690 $52,650 $67,340 $75,480 $82,440 $100,020 $109,800

Instructions:

ALL PRICES ARE F.O.B.

LATTNER IS NOT RESPONSIBLE FOR DETERMINING CITY, COUNTY, STATE, FEDERAL, OR INSURANCE CODE REQUIREMENTS. IT IS THE SOLE RESPONSIBILITY OF THE REPRESENTATIVE, DISTRIBUTOR, AND/OR CUSTOMER TO DETERMINE APPLICABLE BOILER CODES.

ENGINEERING CHANGES, INCLUDING WIRING DIAGRAM AND EQUIPMENT SUPPLY CHANGES, MADE AFTER SUBMITTAL APPROVAL WILL BE INVOICED AT $90 (NET) PER HOUR.

Boiler Size (HP) / Price (USD)

Boiler Size (HP) / Price (USD)

Step 3) Select options (refer to following options pages).

Step 1) Select vessel (refer to sizes and prices above).Step 2) Select burner (refer to following burner pages).

POWER BURNERS MUST BE STARTED BY QUALIFIED PERSONNEL USING COMBUSTION ANALYZER. WARRANTY VALIDATION AND START-UP REPORT MUST BE RETURNED TO LATTNER FOLLOWING START-UP.

6

Page 7: LIST PRICES FOR LATTNER BOILERS & ACCESSORIESlattner.com/userfiles/literature/lattner prices march 2013.pdf · Lattner Boiler Company Vertical Steam Boiler Options March 1st, 2013

Lattner Boiler CompanyScotch Marine Burners (Only)

March 1st, 2013Bulletin: SB121

Lattner Boiler CompanyP.O. Box 15271411 9th St. SWCedar Rapids, IA 52406

Telephone: (800) 345-1527Fax: (319) 366-0770

Email: [email protected]: www.lattnerboiler.com

UL / CSD-1 10 15 20 25 30 40 50ON/OFF $7,020 $7,020 $7,670Low Fire Start $7,870 $7,870 $8,640 $8,650 $8,850 $9,870 $10,840Modulating $9,500 $9,680 $10,370 $11,230Low-NOx $15,320 $15,320 $15,320 $16,080 $17,020 $18,720 $19,510

FM 10 15 20 25 30 40 50ON/OFF $6,420 $7,020 $7,670Low Fire Start $7,870 $7,870 $8,650 $8,650 $8,850 $9,870 $10,840Modulating $10,450 $10,650 $11,410 $12,360Low-NOx $15,320 $15,320 $15,320 $16,080 $17,020 $18,720 $19,510

IRI / GE GAP 10 15 20 25 30 40 50ON/OFF $9,870 $9,870 $10,720Low Fire Start $9,960 $9,960 $10,990 $10,990 $11,200 $11,030 $12,280Modulating $14,260 $14,470 $14,840 $15,610Low-NOx $15,320 $15,320 $15,320 $16,080 $17,020 $18,720 $19,510

UL / CSD-1 60 80 100 125 150 200 250ON/OFFLow Fire Start $12,200 $13,490 $13,490Modulating $14,050 $15,490 $15,490 $20,070 $20,070 $21,210 $21,210Low-NOx $20,590 $20,970 $22,530 $27,550 $28,760 $31,190 $44,170

FM 60 80 100 125 150 200 250ON/OFFLow Fire Start $12,680 $14,150 $14,150Modulating $14,520 $17,290 $17,290 $20,180 $20,180 $22,140 $22,140Low-NOx $20,590 $20,970 $22,530 $27,550 $28,760 $31,190 $44,170

IRI / GE GAP 60 80 100 125 150 200 250ON/OFFLow Fire Start $13,800 $14,850 $14,850Modulating $16,880 $17,920 $17,920 $21,170 $21,170 $22,300 $22,300Low-NOx $20,590 $20,970 $22,530 $27,550 $28,760 $31,190 $44,170

POWER BURNERS MUST BE STARTED BY QUALIFIED PERSONNEL USING COMBUSTION ANALYZER. WARRANTY VALIDATION AND START-UP REPORT MUST BE RETURNED TO LATTNER FOLLOWING START-UP.

ALL PRICES ARE F.O.B. FACTORY AND SUBJECT TO CHANGE WITHOUT NOTICE.

Natural or LP Gas Burners:

Boiler Size (HP) / Price (USD)Natural or LP Gas Burners:

Boiler Size (HP) / Price (USD)

7

Page 8: LIST PRICES FOR LATTNER BOILERS & ACCESSORIESlattner.com/userfiles/literature/lattner prices march 2013.pdf · Lattner Boiler Company Vertical Steam Boiler Options March 1st, 2013

Lattner Boiler CompanyScotch Marine Burners (Only)

March 1st, 2013Bulletin: SB121

Lattner Boiler CompanyP.O. Box 15271411 9th St. SWCedar Rapids, IA 52406

Telephone: (800) 345-1527Fax: (319) 366-0770

Email: [email protected]: www.lattnerboiler.com

UL / CSD-1 10 15 20 25 30 40 50ON/OFF $6,670 $6,670 $6,670Low Fire Start $7,470 $7,470 $7,470 $7,470 $7,670 $7,880 $7,970Modulating $10,070 $10,280 $10,310 $10,390

FM 10 15 20 25 30 40 50ON/OFF $6,670 $6,670 $6,670Low Fire Start $7,470 $7,470 $7,470 $7,470 $7,670 $7,880 $7,880Modulating $10,070 $68,950 $10,270 $10,270

IRI / GE GAP 10 15 20 25 30 40 50ON/OFF $7,990 $7,990 $7,990Low Fire Start $8,630 $8,630 $8,630 $8,630 $8,840 $8,960 $9,050Modulating $12,040 $12,240 $12,190 $12,380

UL / CSD-1 60 80 100 125 150 200 250ON/OFFLow Fire Start $9,320 $10,310 $10,310Modulating $10,600 $11,600 $11,600 $18,340 $18,340 $19,750 $19,750

FM 60 80 100 125 150 200 250ON/OFFLow Fire Start $10,230 $11,510 $11,510Modulating $11,550 $14,180 $14,180 $18,610 $18,610 $20,010 $20,010

IRI / GE GAP 60 80 100 125 150 200 250ON/OFFLow Fire Start $10,510 $11,540 $11,540Modulating $13,610 $14,600 $14,600 $19,390 $19,390 $21,050 $21,050

POWER BURNERS MUST BE STARTED BY QUALIFIED PERSONNEL USING COMBUSTION ANALYZER. WARRANTY VALIDATION AND START-UP REPORT MUST BE RETURNED TO LATTNER FOLLOWING START-UP.

ALL PRICES ARE F.O.B. FACTORY AND SUBJECT TO CHANGE WITHOUT NOTICE.

Pressure Atomizing #2 Oil Burners:

Boiler Size (HP) / Price (USD)Pressure Atomizing #2 Oil Burners:

Boiler Size (HP) / Price (USD)

8

Page 9: LIST PRICES FOR LATTNER BOILERS & ACCESSORIESlattner.com/userfiles/literature/lattner prices march 2013.pdf · Lattner Boiler Company Vertical Steam Boiler Options March 1st, 2013

Lattner Boiler CompanyScotch Marine Burners (Only)

March 1st, 2013Bulletin: SB121

Lattner Boiler CompanyP.O. Box 15271411 9th St. SWCedar Rapids, IA 52406

Telephone: (800) 345-1527Fax: (319) 366-0770

Email: [email protected]: www.lattnerboiler.com

UL / CSD-1 10 15 20 25 30 40 50ON/OFF $8,200 $8,200 $8,740Low Fire Start $9,870 $9,870 $10,640 $10,640 $10,850 $11,850 $12,750Modulating $12,290 $12,490 $13,750 $14,580Low-NOx

FM 10 15 20 25 30 40 50ON/OFF $8,200 $8,200 $8,200Low Fire Start $9,870 $9,870 $10,640 $10,640 $10,850 $11,850 $12,750Modulating $12,290 $12,490 $13,750 $14,580Low-NOx

IRI / GE GAP 10 15 20 25 30 40 50ON/OFF $10,420 $10,420 $11,960Low Fire Start $11,620 $11,620 $13,480 $13,480 $13,680 $14,260 $14,820Modulating $15,660 $15,860 $17,250 $17,900Low-NOx

UL / CSD-1 60 80 100 125 150 200 250ON/OFFLow Fire Start $14,070 $15,340 $15,340Modulating $15,780 $17,380 $17,380 $20,150 $20,150 $26,270 $26,270Low-NOx

FM 60 80 100 125 150 200 250ON/OFFLow Fire Start $14,520 $15,800 $15,800Modulating $16,080 $18,950 $18,950 $24,070 $24,070 $27,280 $27,280Low-NOx

IRI / GE GAP 60 80 100 125 150 200 250ON/OFFLow Fire Start $15,500 $16,830 $16,830Modulating $18,980 $19,780 $19,780 $24,370 $24,370 $27,760 $27,760Low-NOx

POWER BURNERS MUST BE STARTED BY QUALIFIED PERSONNEL USING COMBUSTION ANALYZER. WARRANTY VALIDATION AND START-UP REPORT MUST BE RETURNED TO LATTNER FOLLOWING START-UP.

ALL PRICES ARE F.O.B. FACTORY AND SUBJECT TO CHANGE WITHOUT NOTICE.

Dual Fuel Burners (Natural Gas & Pressure Atomizing #2 Oil; Natural Gas Pilot):

Boiler Size (HP) / Price (USD)Dual Fuel Burners (Natural Gas & Pressure Atomizing #2 Oil; Natural Gas Pilot):

Boiler Size (HP) / Price (USD)

9

Page 10: LIST PRICES FOR LATTNER BOILERS & ACCESSORIESlattner.com/userfiles/literature/lattner prices march 2013.pdf · Lattner Boiler Company Vertical Steam Boiler Options March 1st, 2013

Lattner Boiler CompanyDry Back Scotch Marine Boiler Options

March 1st, 2013Bulletin: SB121

Lattner Boiler CompanyP.O. Box 15271411 9th St. SWCedar Rapids, IA 52406

Telephone: (800) 345-1527Fax: (319) 366-0770

Email: [email protected]: www.lattnerboiler.com

Burner Options: 10 15 20 25 30 40 50Cam-netic Fuel Valve for Natural or LP $860 $860 $860 $860 $860 $860 $860Cam-netic Fuel Valve for Dual Fuel call call call call call call callCam-netic Fuel Valve for #2 Oil $950 $950 $950 $950 $950 $950 $950Direct Vent $230 $230 $230 $230 $230 $230 $230Air Inlet Silencer (90 dba) $390 $390 $390 $390 $390 $390 $550

Electrical Options: 10 15 20 25 30 40 50Honeywell Digital Display Module $530 $530 $530 $530 $530 $530 $5303 Phase/Alternate Voltages $540 $350 $350 $350 $400 $400 $400Control Circuit Transformer $380 $380 $380 $380 $380 $380 $380Door Interlock $100 $100 $100 $100 $100 $100 $100Proven Low Fire Start (PLFS) $150 $150 $150 $150 $150 $150 $150Additional Dry Contacts $220 $220 $220 $220 $220 $220 $220Cabinet Lock and Key $210 $210 $210 $210 $210 $210 $210Panel Lights (5 light package) $90 $90 $90 $90 $90 $90 $90

Trim & Blowdown Options: 10 15 20 25 30 40 50Valve Package (high pressure steam)1 $1,380 $1,380 $1,380 $1,380 $1,380 $1,380 $1,450Valve Package (low pressure steam)1 $1,230 $1,230 $1,230 $1,230 $1,230 $1,230 $1,280Steam Non-Return Valves $3,600 $3,600 $3,600 $3,600 $3,600 $3,600 $3,600Valve Package (hot water) $830 $830 $830 $830 $890 $890 $890Drip Pan Elbows $350 $350 $350 $350 $350 $350 $350ASME Piping Hydro P-6 Data Report2 $250 $250 $250 $250 $250 $250 $250Low Water Level Alarm (LWL-1) $250 $250 $250 $250 $250 $250 $250High Water Level Alarm (HWL-1) $460 $460 $460 $460 $460 $460 $460Float Type Auxiliary LWCO $840 $630 $630 $630 $630 $630 $630Night Operation Pressure Switch $280 $280 $280 $280 $280 $280 $280Automatic Bottom Blowdown $1,320 $1,320 $1,320 $1,320 $1,320 $1,320 $1,320Manual Surface Blowoff $230 $230 $230 $230 $230 $230 $230Automatic Surface Blowoff $1,100 $1,100 $1,100 $1,100 $1,100 $1,100 $1,100TDS/Conductivity Surface Blowoff $3,900 $3,900 $3,900 $3,900 $3,900 $3,900 $3,900Stack Thermometer $150 $150 $150 $150 $150 $150 $150Barometric Damper $220 $220 $220 $220 $270 $340 $390

Other Options: 10 15 20 25 30 40 50Additional Manuals (each)3 $30 $30 $30 $30 $30 $30 $30Additional Submittals (each)4 $15 $15 $15 $15 $15 $15 $15Factory Start-Up5 $1,400 $1,400 $1,400 $1,400 $1,400 $1,400 $1,400

Notes:

Boiler Size (HP) / Price (USD)

1) Valve package includes main steam stop, feedwater stop, feedwater check, slow open blowdown, and quick open blowdown valves.2) ASME piping and hydrostatic test w/P-6 data report is required in AZ, CO, IA, IN, KS, KY, NE, OH, VA, WI.

ALL PRICES ARE F.O.B. FACTORY AND SUBJECT TO CHANGE WITHOUT NOTICE.

3) One instruction manual will be provided with the boiler no charge at the time of the boiler order. One additional manual will be provided no charge at the time of the order if requested. Additional manuals or manuals requested after the boiler is shipped will be invoiced at $30 each.4) Two sets of submittals will be provided with the boiler no charge at the time of the boiler order. One additional digital (email) set of submittals will be provided no charge at the time of the order if requested. Additional submittals or submittals requested after the boiler is shipped will be invoiced at $15 each.5) Boiler start-up by a factory authorized representative may be requested for a net cost of $1400 per day plus travel and expenses. Boiler start-up cannot be scheduled until start-up request has been returned to Lattner.

10

Page 11: LIST PRICES FOR LATTNER BOILERS & ACCESSORIESlattner.com/userfiles/literature/lattner prices march 2013.pdf · Lattner Boiler Company Vertical Steam Boiler Options March 1st, 2013

Lattner Boiler CompanyDry Back Scotch Marine Boiler Options Continued

March 1st, 2013Bulletin: SB121

Lattner Boiler CompanyP.O. Box 15271411 9th St. SWCedar Rapids, IA 52406

Telephone: (800) 345-1527Fax: (319) 366-0770

Email: [email protected]: www.lattnerboiler.com

Burner Options: 60 80 100 125 150 200 250Cam-netic Fuel Valve for Natural or LP $860 $860 $860 $860 $860 $860 $860Cam-netic Fuel Valve for Dual Fuel call call call call call call callCam-netic Fuel Valve for #2 Oil $950 $950 $950 $950 $950 $950 $950Direct Vent $290 $290 $290 $290 $290 $290 $290Air Inlet Silencer (90 dba) $550 $550 $550 $550 $550 $550 $550

Electrical Options: 60 80 100 125 150 200 250Honeywell Digital Display Module $530 $530 $530 $530 $530 $530 $5303 Phase/Alternate Voltages $540 $350 $350 $350 $400 $400 $400Control Circuit Transformer $380 $340 $340 $340 $340 $340 $340Door Interlock $100 $100 $100 $100 $100 $100 $100Proven Low Fire Start (PLFS) $150 $130 $130 $130 $130 $130 $130Additional Dry Contacts $220 $180 $180 $180 $180 $180 $180Cabinet Lock and Key $210 $170 $170 $170 $170 $170 $170Panel Lights (5 light package) $90 $50 $50 $50 $50 $50 $50

Trim & Blowdown Options: 60 80 100 125 150 200 250Valve Package (high pressure steam)1 $1,600 $2,620 $2,780 $2,780 $2,780 $3,150 $3,320Valve Package (low pressure steam)1 $1,280 $2,110 $2,230 $2,230 $2,230 $2,520 $2,660Steam Non-Return Valves $3,960 $4,160 $4,370 $4,590 $4,820 $5,060 $5,320Valve Package (hot water) $890 $1,020 $1,210 $1,210 $1,210 $1,590 $1,590Drip Pan Elbows $350 $350 $350 $350 $350 $350 $350ASME Piping Hydro P-6 Data Report2 $250 $250 $250 $250 $250 $250 $250Low Water Level Alarm (LWL-1) $250 $250 $250 $250 $250 $250 $250High Water Level Alarm (HWL-1) $460 $460 $460 $460 $460 $460 $460Float Type Auxiliary LWCO $840 $630 $630 $630 $630 $630 $630Night Operation Pressure Switch $280 $280 $280 $280 $280 $280 $280Automatic Bottom Blowdown $1,320 $1,320 $1,750 $1,750 $1,840 $1,940 $2,040Manual Surface Blowoff $230 $230 $230 $230 $230 $230 $230Automatic Surface Blowoff $1,100 $1,100 $1,100 $1,100 $1,100 $1,100 $1,100TDS/Conductivity Surface Blowoff $3,900 $3,900 $3,900 $3,900 $3,900 $3,900 $3,900Stack Thermometer $150 $150 $150 $150 $150 $150 $150Barometric Damper $390 $390 $420 $420 $420 $420 $850

Other Options: 60 80 100 125 150 200 250Additional Manuals (each)3 $30 $30 $30 $30 $30 $30 $30Additional Submittals (each)4 $15 $15 $15 $15 $15 $15 $15Factory Start-Up5 $1,400 $1,400 $1,400 $1,400 $1,400 $1,400 $1,400

Notes:

4) Two sets of submittals will be provided with the boiler no charge at the time of the boiler order. One additional digital (email) set of submittals will be provided no charge at the time of the order if requested. Additional submittals or submittals requested after the boiler is shipped will be invoiced at $15 each.5) Boiler start-up by a factory authorized representative may be requested for a net cost of $1400 per day plus travel and expenses. Boiler start-up cannot be scheduled until start-up request has been returned to Lattner.

ALL PRICES ARE F.O.B. FACTORY AND SUBJECT TO CHANGE WITHOUT NOTICE.

Boiler Size (HP) / Price (USD)

1) Valve package includes main steam stop, feedwater stop, feedwater check, slow open blowdown, and quick open blowdown valves.2) ASME piping and hydrostatic test w/P-6 data report is required in AZ, CO, IA, IN, KS, KY, NE, OH, VA, WI.3) One instruction manual will be provided with the boiler no charge at the time of the boiler order. One additional manual will be provided no charge at the time of the order if requested. Additional manuals or manuals requested after the boiler is shipped will be invoiced at $30 each.

11

Page 12: LIST PRICES FOR LATTNER BOILERS & ACCESSORIESlattner.com/userfiles/literature/lattner prices march 2013.pdf · Lattner Boiler Company Vertical Steam Boiler Options March 1st, 2013

Lattner Boiler CompanyLattner Steam Room Packages (Gas-Fired Boilers)

March 1st, 2013Bulletin: SB113

Lattner Boiler CompanyP.O. Box 15271411 9th St. SWCedar Rapids, IA 52406

Telephone: (800) 345-1527Fax: (319) 366-0770

Email: [email protected]: www.lattnerboiler.com

Boiler (HP): PRICE LOW-NOX1-1/2 $6,9003 $8,640 $11,2105 $9,590 $12,0707 $12,890 $16,0909-1/2 $13,900 $1,020

Boiler (HP): PRICE LOW-NOX1-1/2 $7,1603 $8,890 $11,4805 $9,840 $12,3407 $13,140 $16,3609-1/2 $14,150 $17,110

$250$70

$1,240$1,220

$90$960$140

Notes:

ALL PRICES ARE F.O.B. FACTORY AND SUBJECT TO CHANGE WITHOUT NOTICE.

ASME Piping Hydro w/P-6 Data Report1

2) One instruction manual will be provided with the boiler no charge at the time of the boiler order. One additional manual will be provided no charge at the time of the order if requested. Additional manuals or manuals requested after the boiler is shipped will be invoiced at $30 each.

Chrome steam head with escutcheon plate (in addition to standard package)Model 1674-B automatic blowdown systemModel 810 blowdown separator

1) ASME piping and hydrostatic test w/P-6 data report is required in AZ, CO, IA, IN, KS, KY, NE, OH, VA, WI.

3) Two sets of submittals will be provided with the boiler no charge at the time of the boiler order. One additional digital (email) set of submittals will be provided no charge at the time of the order if requested. Additional submittals or submittals requested after the boiler is shipped will be invoiced at $15 each.

Model 205A automatic aftercooler

Max. steam room volume of 3800 cubic feet (two steam heads)

Max. steam room volume (two steam rooms) of 600 cubic feet

SL-2 blowdown separator leg set

Dual steam room package includes one steam generator, dual input digital room temperature controller, two water proof sensors with shields, two steam solenoid valves, one feedwater solenoid valve (factory wired), and two chrome steam heads.

Options:

Model DT-2 dial thermometer for aftercooler

Max. steam room volume (two steam rooms) of 3800 cubic feet (two steam heads)

Max. steam room volume (two steam rooms) of 1200 cubic feetMax. steam room volume (two steam rooms) of 2000 cubic feet

Single steam room package includes one steam generator, digital room temperature controller, one water proof sensor with shield, one steam solenoid valve, one feedwater solenoid valve (factory wired), and one chrome steam head.

DUAL STEAM ROOM APPLICATIONSteam Room Size (FT3)

Max. steam room volume (two steam rooms) of 2800 cubic feet (two steam heads)

Max. steam room volume of 2000 cubic feetMax. steam room volume of 2800 cubic feet (two steam heads)

All steam generators include as standard equipment: McDonnell Miller Level control and low water cut-off, probe-type auxiliary low water cut-off, operating pressure switch, high limit pressure switch, safety relief valve, blowdown vales for boiler and level controls, main steam stop valve, feedwater stop and check valves, water gauge set and draft diverter, UL approved and listed, factory wired for 120/1/60. ASME Code and National Board stamped.

SINGLE STEAM ROOM APPLICATIONSteam Room Size (FT3)

Max. steam room volume of 600 cubic feetMax. steam room volume of 1200 cubic feet

12

Page 13: LIST PRICES FOR LATTNER BOILERS & ACCESSORIESlattner.com/userfiles/literature/lattner prices march 2013.pdf · Lattner Boiler Company Vertical Steam Boiler Options March 1st, 2013

Lattner Boiler CompanyLattner Steam Room Packages (Electric Boilers)

March 1st, 2013Bulletin: SB106

Lattner Boiler CompanyP.O. Box 15271411 9th St. SWCedar Rapids, IA 52406

Telephone: (800) 345-1527Fax: (319) 366-0770

Email: [email protected]: www.lattnerboiler.com

Boiler (KW): 480/3 208-240/3 240/19 $5,850 $5,850 $5,91015 $5,920 $5,920 $6,20018 $5,990 $6,060 $6,39024 $6,790 $7,000 $7,12030 $7,220 $7,290 $7,56036 $7,400 $7,630 $8,14048 $8,280 $9,080 $9,660

Boiler (KW): 480/3 208-240/3 240/19 $6,110 $6,110 $6,16015 $6,170 $6,170 $6,45018 $6,240 $6,320 $6,64024 $7,040 $7,250 $7,38030 $7,470 $7,540 $7,82036 $7,650 $7,880 $8,39048 $8,530 $9,330 $9,920

$70$1,240$1,220

$90$960$140

Notes:

Maximum steam room volume of 1920 cubic feet (two steam heads)

Single steam room package includes one steam generator, digital room temperature controller, one water proof sensor with shield, one steam solenoid valve, one feedwater valve assembly (factory wired), and one steam head.

Model 810 blowdown separatorSL-2 blowdown separator leg set

Maximum steam room volume of 720 cubic feet

Model DT-2 dial thermometer for aftercooler

Maximum steam room volume of 960 cubic feetMaximum steam room volume of 1200 cubic feetMaximum steam room volume of 1440 cubic feet (two steam heads)Maximum steam room volume of 1920 cubic feet (two steam heads)

Dual steam room package includes one steam generator, dual input digital room temperature controller, two water proof sensors with shields , two steam solenoid valves assemblies (factory wired) and two steam heads.

Chrome steam head with escutcheon plate (in addition to standard package)Model 1674-B automatic blowdown system

Options:

Model 205A automatic aftercooler

ALL PRICES ARE F.O.B. FACTORY AND SUBJECT TO CHANGE WITHOUT NOTICE.

1) One instruction manual will be provided with the boiler no charge at the time of the boiler order. One additional manual will be provided no charge at the time of the order if requested. Additional manuals or manuals requested after the boiler is shipped will be invoiced at $30 each.2) Two sets of submittals will be provided with the boiler no charge at the time of the boiler order. One additional digital (email) set of submittals will be provided no charge at the time of the order if requested. Additional submittals or submittals requested after the boiler is shipped will be invoiced at $15 each.

All steam generators include internal wiring complete and ready for connection to electrical service, heating elements with magnetic contactors and internal circuits subdivided with all ungrounded circuits fused, McDonnell Miller level control and probe-type auxiliary low water cut-off, water gauge set, pressure relief valve, blowdown valves for boiler and control, boiler on/off switch, and high limit pressure control. ASME Code and National Board stamped.

SINGLE STEAM ROOM APPLICATIONSteam Room Size (FT3)

Maximum steam room volume of 360 cubic feetMaximum steam room volume of 600 cubic feetMaximum steam room volume of 720 cubic feet

DUAL STEAM ROOM APPLICATIONSteam Room Size (FT3)

Maximum steam room volume of 360 cubic feetMaximum steam room volume of 600 cubic feet

Maximum steam room volume of 960 cubic feetMaximum steam room volume of 1200 cubic feetMaximum steam room volume of 1440 cubic feet (two steam heads)

13

Page 14: LIST PRICES FOR LATTNER BOILERS & ACCESSORIESlattner.com/userfiles/literature/lattner prices march 2013.pdf · Lattner Boiler Company Vertical Steam Boiler Options March 1st, 2013

Lattner Boiler CompanyLattner Horizontal Electric Steam Boilers

March 1st, 2013Bulletin: SB106

Lattner Boiler CompanyP.O. Box 15271411 9th St. SWCedar Rapids, IA 52406

Telephone: (800) 345-1527Fax: (319) 366-0770

Email: [email protected]: www.lattnerboiler.com

Model (480v)

Price (USD)

Model (208v)

Model (240v)

Price (USD)

Model (240v)

Price (USD)

9 0.9 100 400 9BF $4,740 9AF 9F $4,740 9CF $4,79015 1.5 100 400 15BF $4,800 15AF 15F $4,800 15CF $5,08018 1.8 100 400 18BF $4,880 18AF 18F $4,950 18CF $5,27024 2.4 100 445 24BF $5,660 24AF 24F $5,870 24CF $5,99030 3 100 445 30BF $6,080 30AF 30F $6,150 30CF $6,42036 3.6 100 500 36BF $6,260 36AF 36F $6,480 36CF $6,99048 4.8 100 650 48BF $7,120 48AF 48F $7,910 48CF $8,48060 6 100 650 60BF $7,830 60AF 60F $8,970 60CF $9,10074 7.4 125 740 74BF $8,280 74AF 74F $9,95093 9.3 125 835 93BF $10,280 93AF 93F $11,510

112 11.2 125 900 112BF $10,730 112AF 112F $12,550130 13 125 940 130BF $11,020 130AF 130F $12,840148 14.8 125 940 148BF $11,290 148AF 148F $12,990

Options:

Notes:

3) Boiler start-up by a factory authorized representative may be requested for a net cost of $1400 per day plus travel and expenses.

1) One instruction manual will be provided with the boiler no charge at the time of the boiler order. One additional manual will be provided no charge at the time of the order if requested. Additional manuals or manuals requested after the boiler is shipped will be invoiced at $30 each.2) Two sets of submittals will be provided with the boiler no charge at the time of the boiler order. One additional digital (email) set of submittals will be provided no charge at the time of the order if requested. Additional submittals or submittals requested after the boiler is shipped will be invoiced at $15 each.

ALL PRICES ARE F.O.B. FACTORY AND SUBJECT TO CHANGE WITHOUT NOTICE.

$420

Progressive sequencer or linear step control with modulating pressuretrol. 3 to 4 steps $8905 to 6 steps $1,130

$620

Door Interlock $100

Night Operation Pressure Switch $280Auxiliary high pressure limit switch, auto reset $320

Time delay relay $120High water level alarm (HWL-1) $460

Stainless steel nipples (below water line) $270

Vacuum breaker installed above water line $110Control circuit transformer with fused primary and secondary. All boilers require 120 volt control circuit supply. When not available, specifiy control transformer.

Additional pressure switch, mounted and wired with one additional step $280

Low Water Level Alarm (LWL-1) $250

Boiler includes incoloy heating elements, magnetic contactors, NEMA-1 panel with boiler and feedwater ON/OFF switch, lamps, McDonnell Miller primary water level control, auxiliary low water cut-off w/manual reset, operating pressure control, high limit w/manual reset, all internal ungrounded circuits subdivided and fused between contactors and source terminals, ASME safety valve, blowdown valve, feedwater stop and check valves, and water gauge set with ball checks and glass protector. UL listed. Meets CSD-1 standard.

Boiler (KW)

Boiler (BHP)

Design Pressure

(PSI)

Ship Weight (LBS)

3 Phase 3 Phase 1 Phase

High pressure ASME design (in lieu of standard design pressure) 125 psi, 9 to 60 kw $540150 psi, 9 to 222 kw

14

Page 15: LIST PRICES FOR LATTNER BOILERS & ACCESSORIESlattner.com/userfiles/literature/lattner prices march 2013.pdf · Lattner Boiler Company Vertical Steam Boiler Options March 1st, 2013

Lattner Boiler CompanySpace Saver Electric Hot Water Boilers

March 1st, 2013Bulletin: SB115

Lattner Boiler CompanyP.O. Box 15271411 9th St. SWCedar Rapids, IA 52406

Telephone: (800) 345-1527Fax: (319) 366-0770

Email: [email protected]: www.lattnerboiler.com

KW MBH Vessel Diameter Steps Circuits AMPs

(480/3)Price

(480/3)AMPs (240/3)

Price (240/3)

AMPs (208/3)

Price (208/3)

AMPs (240/1)

Price (240/1)

AMPs (208/1)

Price (208/1)

Shipping Weight

7.5 25.6 8.0 1 1 9.0 $5,820 18.0 $5,950 20.8 $6,000 31.3 $5,950 36.1 $6,000 48010 34.1 8.0 1 1 12.0 $5,850 24.1 $5,970 27.8 $6,030 41.7 $5,970 48.1 $6,030 490

12.5 42.7 8.0 1 1 15.0 $5,860 30.1 $5,980 34.7 $6,040 52.1 $5,980 60.1 $6,040 49015.0 51.2 8.0 1 1 18.0 $5,870 36.1 $5,990 41.6 $6,050 62.5 $5,990 72.1 $6,050 49020 68.3 8.0 1 1 24.1 $6,020 48.1 $6,140 55.5 $6,210 83.3 $6,140 96.2 $6,210 500

22.5 76.8 8.0 1 1 27.1 $6,030 54.1 $6,150 62.5 $6,220 93.8 $6,150 108.2 $6,220 50025.0 85.3 8.0 1 1 30.1 $6,040 60.1 $6,160 69.4 $6,230 104.2 $6,160 120.2 $6,230 50030.0 102.4 8.0 1 1 36.1 $6,260 72.2 $6,390 83.3 $6,450 125.0 $6,390 144.2 $6,450 50035 119.5 8.0 1 2 42.1 $6,140 84.2 $6,270 97.2 $6,330 145.8 $6,270 168.3 $6,330 51040 136.5 8.0 1 2 48.1 $6,430 96.2 $6,570 111.0 $6,630 166.7 $6,570 192.3 $6,630 53045 153.6 8.0 2 2 54.1 $6,370 108.3 $6,500 124.9 $6,570 187.5 $6,500 216.3 $6,570 53055 187.7 8.0 2 2 66.2 $6,480 132.3 $6,620 152.7 $6,680 229.2 $6,620 264.4 $6,680 54060 204.8 8.0 2 2 72.2 $6,500 144.3 $6,640 166.5 $6,700 250.0 $6,640 288.5 $6,700 55075 256.0 8.0 2 3 90.2 $6,940 180.4 $7,080 208.2 $7,150 312.5 $7,080 360.6 $7,150 57080 273.0 8.0 3 3 96.2 $7,180 192.5 $7,330 222.1 $7,400 333.3 $7,330 384.6 $7,400 60090 307.2 8.0 3 3 108.3 $7,070 216.5 $7,210 249.8 $7,290 375.0 $7,210 432.7 $7,290 600

105 358.4 8.0 4 4 126.3 $7,370 252.6 $7,520 291.5 $7,600 437.5 $7,520 504.8 $7,600 600120 409.6 8.0 4 4 144.3 $7,500 288.7 $7,660 333.1 $7,730 500.0 $7,660 576.9 $7,730 600135 460.8 10.0 4 4 162.4 $8,720 324.8 $8,890 374.7 $8,990 562.5 649.0 760150 512.0 10.0 4 5 180.4 $8,810 360.8 $9,000 416.4 $9,080 625.0 721.2 760165 563.1 10.0 4 6 198.5 $8,950 396.9 $9,130 458.0 $9,220 687.5 793.3 800180 614.3 12.0 4 6 216.5 $12,270 433.0 $12,520 499.6 $12,640 750.0 865.4 950195 665.5 12.0 4 6 234.5 $12,410 469.1 $12,660 541.3 $12,790 812.5 937.5 1000210 716.7 12.0 4 7 252.6 $13,670 505.2 $13,950 582.9 $14,090 875.0 1009.6 1120225 767.9 12.0 4 7 270.6 $13,830 541.3 $14,110 624.5 $14,250 937.5 1081.7 1200240 819.1 12.0 4 8 288.7 $14,060 577.4 $14,350 666.2 $14,490 1000.0 1153.8 1300

Space Saver is UL listed and includes internal wiring complete and ready for connection to electrical service, incoloy heating elements with magnetic contactors and internal circuits subdivided with all ungrounded circuits fused, operating and high limit temperature controls, pressure-temperature gauge, low water cut-off, relief valve, drain valve for boiler, fused control transformer, and ON/OFF switch. Manual resets provided for low water and high temperature limit. See Lattner bulletin SB115 for description of standard control equipment. DESIGN PRESSURE 160 PSI MAX., ASME "H" STAMP.

15

Page 16: LIST PRICES FOR LATTNER BOILERS & ACCESSORIESlattner.com/userfiles/literature/lattner prices march 2013.pdf · Lattner Boiler Company Vertical Steam Boiler Options March 1st, 2013

Lattner Boiler CompanySpace Saver Electric Hot Water Boilers

March 1st, 2013Bulletin: SB115

Lattner Boiler CompanyP.O. Box 15271411 9th St. SWCedar Rapids, IA 52406

Telephone: (800) 345-1527Fax: (319) 366-0770

Email: [email protected]: www.lattnerboiler.com

Notes:

ALL PRICES ARE F.O.B. FACTORY AND SUBJECT TO CHANGE WITHOUT NOTICE.

1) One instruction manual will be provided with the boiler no charge at the time of the boiler order. One additional manual will be provided no charge at the time of the order if requested. Additional manuals or manuals requested after the boiler is shipped will be invoiced at $25 each.

2) Two sets of submittals will be provided with the boiler no charge at the time of the boiler order. One additional digital (email) set of submittals will be provided no charge at the time of the order if requested. Additional submittals or submittals requested after the boiler is shipped will be invoiced at $15 each.

3) Boiler start-up by a factory authorized representative may be requested for a net cost of $1000 per day plus travel and expenses.

ENGINEERING CHANGES, INCLUDING WIRING DIAGRAM AND EQUIPMENT SUPPLY CHANGES, MADE AFTER SUBMITTAL APPROVAL WILL BE INVOICED AT $90 (NET) PER HOUR.

16

Page 17: LIST PRICES FOR LATTNER BOILERS & ACCESSORIESlattner.com/userfiles/literature/lattner prices march 2013.pdf · Lattner Boiler Company Vertical Steam Boiler Options March 1st, 2013

Lattner Boiler CompanySpace Saver Electric Hot Water Boiler Options

March 1st, 2013Bulletin: SB115

Lattner Boiler CompanyP.O. Box 15271411 9th St. SWCedar Rapids, IA 52406

Telephone: (800) 345-1527Fax: (319) 366-0770

Email: [email protected]: www.lattnerboiler.com

Price (USD)$280$290$720$100

$400$410$530$930

$1,350$2,130$2,650

Call

$720$1,530

Call

$800$1,090

$90$230$250$600

$1,110$430

$3,050$1,740

$90$1,680$200$320

Notes:

400 ampsMore than 400 amps

Main safety disconnect (fused):

60 amps80 amps100 amps125 amps200 amps

Flow switch (packed separately) with interlock terminalsAlarm bell (standard for low water)Ammeter, flush mounted in panel with current transformer(s): 1 phase (continuous duty)

3 phase (selector switch)

1) One instruction manual will be provided with the boiler no charge at the time of the boiler order. One additional manual will be provided no charge at the time of the order if requested. Additional manuals or manuals requested after the boiler is shipped will be invoiced at $30 each.

Voltmeter, flush mounted in panelEnergy meter, KWH, 3 phase amps, and voltage. Includes digital display and CT sensors.

Interlock relays for alarm, status, annunciation, dry contacts (per relay)

Oversized hot water inlet and outlet 3" in lieu of 2" (8" vessel)4" in lieu of 3" (10" and 12" vessels)

National Sanitation Foundation approved plasite vessel liner and stainless steel fittings

Outdoor air reset control (1:1 standard) for hot water and outdoor air sensors

Optional Accessories:Auxiliary low water cut-off, probe type with auto resetAuxiliary high temperature limit w/auto reset, mounted and wired (specify set point)

GFI-1B ground fault protector with CT sensor and test, manual reset

Door interlock switch (wired in 120V control circuit)Main safety disconnect switch (interlocking, non-fused):

- Progressive sequencing5 to 8 steps2 to 4 steps

100 amps200 ampsOther amperages

Energy saver/load limit switch (per switch)

Solid state step control (in lieu of standard aquastat):

250 amps

17

Page 18: LIST PRICES FOR LATTNER BOILERS & ACCESSORIESlattner.com/userfiles/literature/lattner prices march 2013.pdf · Lattner Boiler Company Vertical Steam Boiler Options March 1st, 2013

Lattner Boiler CompanySpace Saver Electric Hot Water Boiler Options

March 1st, 2013Bulletin: SB115

Lattner Boiler CompanyP.O. Box 15271411 9th St. SWCedar Rapids, IA 52406

Telephone: (800) 345-1527Fax: (319) 366-0770

Email: [email protected]: www.lattnerboiler.com

ALL PRICES ARE F.O.B. FACTORY AND SUBJECT TO CHANGE WITHOUT NOTICE.

2) Two sets of submittals will be provided with the boiler no charge at the time of the boiler order. One additional digital (email) set of submittals will be provided no charge at the time of the order if requested. Additional submittals or submittals requested after the boiler is shipped will be invoiced at $15 each.

3) Boiler start-up by a factory authorized representative may be requested for a net cost of $1400 per day plus travel and expenses. Boiler start-up cannot be scheduled until start-up request has been returned to Lattner.

18

Page 19: LIST PRICES FOR LATTNER BOILERS & ACCESSORIESlattner.com/userfiles/literature/lattner prices march 2013.pdf · Lattner Boiler Company Vertical Steam Boiler Options March 1st, 2013

Lattner Boiler CompanyCabinet Style Electric Hot Water Boilers (480v)

March 1st, 2013SB117

Lattner Boiler CompanyP.O. Box 15271411 9th St. SWCedar Rapids, IA 52406

Telephone: (800) 345-1527Fax: (319) 366-0770

Email: [email protected]: www.lattnerboiler.com

KW MBH Amps StepsWeight (LBS) Price (USD)

270 LW 480 8 270 922 325 8 2,400 $17,510300 LW 480 8 300 1,024 361 8 2,400 $18,420330 LW 480 8 330 1,126 397 8 2,400 $19,390360 LW 480 8 360 1,229 434 8 2,400 $20,410390 LW 480 8 390 1,331 470 8 3,450 $21,480420 LW 480 8 420 1,433 506 8 3,450 $22,600450 LW 480 8 450 1,536 542 8 3,450 $23,790480 LW 480 8 480 1,638 578 8 3,750 $25,040510 LW 480 8 510 1,741 614 8 3,750 $26,350540 LW 480 12 540 1,843 650 12 3,750 $27,740570 LW 480 12 570 1,945 686 12 3,750 $29,190600 LW 480 12 600 2,048 723 12 3,750 $29,850630 LW 480 12 630 2,150 759 12 3,750 $30,510660 LW 480 12 660 2,253 795 12 3,750 $31,180690 LW 480 12 690 2,355 831 12 3,750 $31,870720 LW 480 12 720 2,457 867 12 3,750 $32,580750 LW 480 16 750 2,560 903 16 4,450 $33,300780 LW 480 16 780 2,662 939 16 4,450 $34,040810 LW 480 16 810 2,765 975 16 4,450 $34,790840 LW 480 16 840 2,867 1,012 16 4,450 $35,560870 LW 480 16 870 2,969 1,048 16 5,760 $36,350900 LW 480 16 900 3,072 1,084 16 5,760 $37,150930 LW 480 16 930 3,174 1,120 16 5,760 $37,970960 LW 480 16 960 3,276 1,156 16 6,320 $38,810990 LW 480 16 990 3,379 1,192 16 6,320 $39,670

1,020 LW 480 16 1,020 3,481 1,228 16 6,320 $40,5601,050 LW 480 16 1,050 3,584 1,264 16 6,320 $41,4501,080 LW 480 16 1,080 3,686 1,301 16 6,320 $42,3601,120 LW 480 16 1,120 3,823 1,349 16 6,320 $43,3001,160 LW 480 16 1,160 3,959 1,397 16 8,300 $44,2501,200 LW 480 16 1,200 4,096 1,445 16 8,300 $45,2301,240 LW 480 16 1,240 4,232 1,493 16 8,300 $46,2301,280 LW 480 16 1,280 4,369 1,541 16 8,300 $47,2401,320 LW 480 16 1,320 4,505 1,590 16 8,300 $48,2801,360 LW 480 16 1,360 4,642 1,638 16 8,300 $49,3501,400 LW 480 16 1,400 4,778 1,686 16 8,300 $50,4501,440 LW 480 16 1,440 4,915 1,734 16 8,300 $51,5601,480 LW 480 16 1,480 5,051 1,782 16 9,550 $52,7001,520 LW 480 24 1,520 5,188 1,830 24 9,550 $53,8701,560 LW 480 24 1,560 5,324 1,879 24 9,550 $55,0601,600 LW 480 24 1,600 5,461 1,927 24 9,550 $56,2701,640 LW 480 24 1,640 5,597 1,975 24 9,550 $57,5101,680 LW 480 24 1,680 5,734 2,023 24 9,550 $58,7801,720 LW 480 24 1,720 5,870 2,071 24 9,550 $60,0901,760 LW 480 24 1,760 6,007 2,119 24 9,550 $61,4101,800 LW 480 24 1,800 6,143 2,168 24 9,550 $62,7601,840 LW 480 24 1,840 6,280 2,216 24 9,550 $64,1501,880 LW 480 24 1,880 6,416 2,264 24 9,550 $65,5701,920 LW 480 24 1,920 6,553 2,312 24 9,550 $67,0201,960 LW 480 24 1,960 6,689 2,360 24 11,700 $68,500

Model:

19

Page 20: LIST PRICES FOR LATTNER BOILERS & ACCESSORIESlattner.com/userfiles/literature/lattner prices march 2013.pdf · Lattner Boiler Company Vertical Steam Boiler Options March 1st, 2013

Lattner Boiler CompanyCabinet Style Electric Hot Water Boilers (480v)

March 1st, 2013SB117

Lattner Boiler CompanyP.O. Box 15271411 9th St. SWCedar Rapids, IA 52406

Telephone: (800) 345-1527Fax: (319) 366-0770

Email: [email protected]: www.lattnerboiler.com

2,000 LW 480 24 2,000 6,826 2,408 24 11,700 $70,0102,040 LW 480 24 2,040 6,963 2,457 24 11,700 $71,5502,080 LW 480 24 2,080 7,099 2,505 24 11,700 $73,1302,160 LW 480 24 2,160 7,372 2,601 24 11,700 $74,7402,240 LW 480 24 2,240 7,645 2,697 24 11,700 $76,3902,320 LW 480 24 2,320 7,918 2,794 24 13,670 $78,0802,400 LW 480 24 2,400 8,191 2,890 24 13,670 $79,8002,480 LW 480 24 2,480 8,464 2,987 24 14,620 $81,5702,560 LW 480 24 2,560 8,737 3,083 24 14,620 $83,3602,640 LW 480 24 2,640 9,010 3,179 24 14,620 $85,2002,720 LW 480 24 2,720 9,283 3,276 24 14,620 $87,0802,800 LW 480 24 2,800 9,556 3,372 24 14,620 $89,0002,880 LW 480 24 2,880 9,829 3,468 24 14,620 $90,9702,960 LW 480 32 2,960 10,102 3,565 32 17,390 $92,9703,040 LW 480 32 3,040 10,376 3,661 32 17,390 $95,0203,120 LW 480 32 3,120 10,649 3,757 32 17,390 $97,1203,200 LW 480 32 3,200 10,922 3,854 32 17,390 $99,2603,280 LW 480 32 3,280 11,195 3,950 32 17,390 $101,4503,360 LW 480 32 3,360 11,468 4,046 32 17,390 $103,6803,440 LW 480 32 3,440 11,741 4,143 32 17,390 $105,9703,520 LW 480 32 3,520 12,014 4,239 32 17,390 $108,3103,600 LW 480 32 3,600 12,287 4,335 32 17,390 $110,700

Notes:

ALL PRICES ARE F.O.B. FACTORY AND SUBJECT TO CHANGE WITHOUT NOTICE.

ENGINEERING CHANGES, INCLUDING WIRING DIAGRAM AND EQUIPMENT SUPPLY CHANGES, MADE AFTER SUBMITTAL APPROVAL WILL BE INVOICED AT $90 (NET) PER HOUR.

2) One instruction manual will be provided with the boiler no charge at the time of the boiler order. One additional manual will be provided no charge at the time of the order if requested. Additional manuals or manuals requested after the boiler is shipped will be invoiced at $30 each.3) Two sets of submittals will be provided with the boiler no charge at the time of the boiler order. One additional digital (email) set of submittals will be provided no charge at the time of the order if requested. Additional submittals or submittals requested after the boiler is shipped will be invoiced at $15 each.4) Boiler start-up by a factory authorized representative may be requested for a net cost of $1400 per day plus travel and expenses. Boiler start-up cannot be scheduled until start-up request has been returned to Lattner.

1) All Lattner cabinet style electric boilers are custom designed to fit your application. They require additional engineering, quality control, and lead time. In addition, all steps are subject to change depending wattage of boiler, voltage, and specifications. Please be aware of these facts when ordering.

20

Page 21: LIST PRICES FOR LATTNER BOILERS & ACCESSORIESlattner.com/userfiles/literature/lattner prices march 2013.pdf · Lattner Boiler Company Vertical Steam Boiler Options March 1st, 2013

Lattner Boiler CompanyCabinet Style Electric Hot Water Boilers (240v)

March 1st, 2013SB117

Lattner Boiler CompanyP.O. Box 15271411 9th St. SWCedar Rapids, IA 52406

Telephone: (800) 345-1527Fax: (319) 366-0770

Email: [email protected]: www.lattnerboiler.com

KW MBH Amps StepsWeight (LBS) Price (USD)

270 LW 240 5 270 922 650 8 2,400 $18,040300 LW 240 5 300 1,024 723 8 2,400 $18,980330 LW 240 10 330 1,126 795 8 2,400 $19,980360 LW 240 10 360 1,229 867 8 2,400 $21,030390 LW 240 10 390 1,331 939 12 3,450 $22,130420 LW 240 10 420 1,433 1,012 12 3,450 $23,280450 LW 240 10 450 1,536 1,084 12 3,450 $24,500480 LW 240 10 480 1,638 1,156 12 3,750 $25,790510 LW 240 10 510 1,741 1,228 12 3,750 $27,150540 LW 240 10 540 1,843 1,301 12 3,750 $28,580570 LW 240 10 570 1,945 1,373 16 3,750 $30,080600 LW 240 10 600 2,048 1,445 16 3,750 $30,750630 LW 240 10 630 2,150 1,517 16 3,750 $31,430660 LW 240 10 660 2,253 1,590 16 3,750 $32,120690 LW 240 10 690 2,355 1,662 16 3,750 $32,840720 LW 240 10 720 2,457 1,734 16 3,750 $33,560750 LW 240 10 750 2,560 1,806 24 4,450 $34,310780 LW 240 10 780 2,662 1,879 24 4,450 $35,060810 LW 240 10 810 2,765 1,951 24 4,450 $35,840840 LW 240 10 840 2,867 2,023 24 4,450 $36,630870 LW 240 10 870 2,969 2,095 24 5,760 $37,440900 LW 240 10 900 3,072 2,168 24 5,760 $38,280930 LW 240 15 930 3,174 2,240 24 5,760 $39,120960 LW 240 15 960 3,276 2,312 24 6,320 $39,980990 LW 240 15 990 3,379 2,384 24 6,320 $40,870

1,020 LW 240 15 1,020 3,481 2,457 24 6,320 $41,7701,050 LW 240 15 1,050 3,584 2,529 24 6,320 $42,7001,080 LW 240 15 1,080 3,686 2,601 24 6,320 $43,6401,120 LW 240 15 1,120 3,823 2,697 24 6,320 $44,6001,160 LW 240 15 1,160 3,959 2,794 24 8,300 $45,5901,200 LW 240 15 1,200 4,096 2,890 24 8,300 $46,5901,240 LW 240 15 1,240 4,232 2,987 24 8,300 $47,620

Notes:

ALL PRICES ARE F.O.B. FACTORY AND SUBJECT TO CHANGE WITHOUT NOTICE.

Model:

1) All Lattner cabinet style electric boilers are custom designed to fit your application. They require additional engineering, quality control, and lead time. In addition, all steps are subject to change depending wattage of boiler, voltage, and specifications. Please be aware of these facts when ordering.2) One instruction manual will be provided with the boiler no charge at the time of the boiler order. One additional manual will be provided no charge at the time of the order if requested. Additional manuals or manuals requested after the boiler is shipped will be invoiced at $30 each.3) Two sets of submittals will be provided with the boiler no charge at the time of the boiler order. One additional digital (email) set of submittals will be provided no charge at the time of the order if requested. Additional submittals or submittals requested after the boiler is shipped will be invoiced at $15 each.4) Boiler start-up by a factory authorized representative may be requested for a net cost of $1400 per day plus travel and expenses. Boiler start-up cannot be scheduled until start-up request has been returned to Lattner.

ENGINEERING CHANGES, INCLUDING WIRING DIAGRAM AND EQUIPMENT SUPPLY CHANGES, MADE AFTER SUBMITTAL APPROVAL WILL BE INVOICED AT $90 (NET) PER HOUR.

21

Page 22: LIST PRICES FOR LATTNER BOILERS & ACCESSORIESlattner.com/userfiles/literature/lattner prices march 2013.pdf · Lattner Boiler Company Vertical Steam Boiler Options March 1st, 2013

Lattner Boiler CompanyCabinet Style Electric Hot Water Boilers (208v)

March 1st, 2013SB117

Lattner Boiler CompanyP.O. Box 15271411 9th St. SWCedar Rapids, IA 52406

Telephone: (800) 345-1527Fax: (319) 366-0770

Email: [email protected]: www.lattnerboiler.com

KW MBH Amps StepsWeight (LBS) Price (USD)

257 LW 208 10 257 875 713 8 2,400 $24,480274 LW 208 10 274 934 760 8 2,400 $24,720291 LW 208 10 291 992 808 8 2,400 $25,140308 LW 208 10 308 1,051 855 8 2,400 $25,670325 LW 208 10 325 1,109 903 8 2,400 $26,330342 LW 208 10 342 1,167 950 8 3,450 $27,080359 LW 208 10 359 1,226 998 12 3,450 $27,940376 LW 208 10 376 1,284 1,045 12 3,450 $28,880393 LW 208 10 393 1,342 1,093 12 3,750 $29,910410 LW 208 10 410 1,401 1,141 12 3,750 $31,020428 LW 208 10 428 1,459 1,188 16 3,750 $32,220445 LW 208 10 445 1,517 1,236 16 3,750 $32,540462 LW 208 10 462 1,576 1,283 16 3,750 $32,900479 LW 208 10 479 1,634 1,331 16 3,750 $33,280496 LW 208 10 496 1,693 1,378 16 3,750 $33,710513 LW 208 10 513 1,751 1,426 16 3,750 $34,160530 LW 208 15 530 1,809 1,473 16 3,750 $34,630547 LW 208 15 547 1,868 1,521 16 4,450 $35,140564 LW 208 17 564 1,926 1,568 16 4,450 $35,670581 LW 208 17 581 1,984 1,616 16 5,760 $36,220599 LW 208 18 599 2,043 1,663 18 5,760 $36,800616 LW 208 18 616 2,101 1,711 18 5,760 $37,390633 LW 208 19 633 2,159 1,758 19 6,320 $38,020650 LW 208 19 650 2,218 1,806 19 6,320 $38,660667 LW 208 20 667 2,276 1,853 20 6,320 $39,330684 LW 208 20 684 2,334 1,901 20 6,320 $40,020701 LW 208 20 701 2,393 1,948 21 6,320 $40,730718 LW 208 20 718 2,451 1,996 21 6,320 $41,450752 LW 208 20 752 2,568 2,091 21 8,300 $42,800

Notes:

ALL PRICES ARE F.O.B. FACTORY AND SUBJECT TO CHANGE WITHOUT NOTICE.

Model:

1) All Lattner cabinet style electric boilers are custom designed to fit your application. They require additional engineering, quality control, and lead time. In addition, all steps are subject to change depending wattage of boiler, voltage, and specifications. Please be aware of these facts when ordering.2) One instruction manual will be provided with the boiler no charge at the time of the boiler order. One additional manual will be provided no charge at the time of the order if requested. Additional manuals or manuals requested after the boiler is shipped will be invoiced at $30 each.3) Two sets of submittals will be provided with the boiler no charge at the time of the boiler order. One additional digital (email) set of submittals will be provided no charge at the time of the order if requested. Additional submittals or submittals requested after the boiler is shipped will be invoiced at $15 each.4) Boiler start-up by a factory authorized representative may be requested for a net cost of $1400 per day plus travel and expenses. Boiler start-up cannot be scheduled until start-up request has been returned to Lattner.

ENGINEERING CHANGES, INCLUDING WIRING DIAGRAM AND EQUIPMENT SUPPLY CHANGES, MADE AFTER SUBMITTAL APPROVAL WILL BE INVOICED AT $90 (NET) PER HOUR.

22

Page 23: LIST PRICES FOR LATTNER BOILERS & ACCESSORIESlattner.com/userfiles/literature/lattner prices march 2013.pdf · Lattner Boiler Company Vertical Steam Boiler Options March 1st, 2013

Lattner Boiler CompanyCabinet Style Electric Steam Boilers (480v)

March 1st, 2013SB116

Lattner Boiler CompanyP.O. Box 15271411 9th St. SWCedar Rapids, IA 52406

Telephone: (800) 345-1527Fax: (319) 366-0770

Email: [email protected]: www.lattnerboiler.com

KW MBH Amps StepsWeight (LBS) Price (USD)

165 HS 480 4 165 563 199 6 1,475 $22,830180 HS 480 4 180 614 217 6 1,475 $24,020195 HS 480 4 195 666 235 7 1,475 $25,280210 HS 480 4 210 717 253 7 1,475 $26,610240 HS 480 4 240 819 289 8 2,400 $28,000270 HS 480 5 270 922 325 8 2,400 $29,470300 HS 480 5 300 1,024 361 8 2,400 $31,020330 HS 480 10 330 1,126 397 8 2,400 $32,650360 HS 480 10 360 1,229 434 8 2,400 $34,360390 HS 480 10 390 1,331 470 8 3,450 $36,160420 HS 480 10 420 1,433 506 8 3,450 $36,890450 HS 480 10 450 1,536 542 8 3,450 $37,630480 HS 480 10 480 1,638 578 8 3,750 $38,390510 HS 480 10 510 1,741 614 12 3,750 $39,170540 HS 480 10 540 1,843 650 12 3,750 $39,960570 HS 480 10 570 1,945 686 12 3,750 $40,760600 HS 480 10 600 2,048 723 12 3,750 $41,590630 HS 480 10 630 2,150 759 12 3,750 $42,420660 HS 480 10 660 2,253 795 12 3,750 $43,280690 HS 480 10 690 2,355 831 12 3,750 $44,150720 HS 480 10 720 2,457 867 12 3,750 $45,040750 HS 480 10 750 2,560 903 16 4,450 $45,940780 HS 480 10 780 2,662 939 16 4,450 $46,870810 HS 480 10 810 2,765 975 16 4,450 $47,810840 HS 480 10 840 2,867 1,012 16 4,450 $48,770870 HS 480 10 870 2,969 1,048 16 5,760 $49,740900 HS 480 10 900 3,072 1,084 16 5,760 $50,740930 HS 480 15 930 3,174 1,120 16 5,760 $51,760960 HS 480 15 960 3,276 1,156 16 6,320 $52,800990 HS 480 15 990 3,379 1,192 16 6,320 $53,860

1,020 HS 480 15 1,020 3,481 1,228 16 6,320 $54,9501,050 HS 480 15 1,050 3,584 1,264 16 6,320 $56,0501,080 HS 480 15 1,080 3,686 1,301 16 6,320 $57,1701,120 HS 480 15 1,120 3,823 1,349 16 6,320 $58,3101,160 HS 480 15 1,160 3,959 1,397 16 8,300 $59,4901,200 HS 480 15 1,200 4,096 1,445 16 8,300 $60,6801,240 HS 480 15 1,240 4,232 1,493 16 8,300 $61,9001,280 HS 480 20 1,280 4,369 1,541 16 8,300 $63,1401,320 HS 480 20 1,320 4,505 1,590 16 8,300 $64,4101,360 HS 480 20 1,360 4,642 1,638 16 8,300 $65,7101,400 HS 480 20 1,400 4,778 1,686 16 8,300 $67,0301,440 HS 480 20 1,440 4,915 1,734 16 8,300 $68,3801,480 HS 480 20 1,480 5,051 1,782 24 9,550 $69,7501,520 HS 480 20 1,520 5,188 1,830 24 9,550 $71,1501,560 HS 480 20 1,560 5,324 1,879 24 9,550 $72,5801,600 HS 480 20 1,600 5,461 1,927 24 9,550 $74,0301,640 HS 480 20 1,640 5,597 1,975 24 9,550 $75,5101,680 HS 480 20 1,680 5,734 2,023 24 9,550 $77,0301,720 HS 480 20 1,720 5,870 2,071 24 9,550 $78,5701,760 HS 480 20 1,760 6,007 2,119 24 9,550 $80,150

Model:

23

Page 24: LIST PRICES FOR LATTNER BOILERS & ACCESSORIESlattner.com/userfiles/literature/lattner prices march 2013.pdf · Lattner Boiler Company Vertical Steam Boiler Options March 1st, 2013

Lattner Boiler CompanyCabinet Style Electric Steam Boilers (480v)

March 1st, 2013SB116

Lattner Boiler CompanyP.O. Box 15271411 9th St. SWCedar Rapids, IA 52406

Telephone: (800) 345-1527Fax: (319) 366-0770

Email: [email protected]: www.lattnerboiler.com

1,800 HS 480 20 1,800 6,143 2,168 24 9,550 $81,7601,840 HS 480 20 1,840 6,280 2,216 24 9,550 $83,3901,880 HS 480 20 1,880 6,416 2,264 24 9,550 $85,0601,920 HS 480 20 1,920 6,553 2,312 24 9,550 $86,7701,960 HS 480 20 1,960 6,689 2,360 24 11,700 $88,5102,000 HS 480 20 2,000 6,826 2,408 24 11,700 $90,2802,040 HS 480 20 2,040 6,963 2,457 24 11,700 $92,1002,080 HS 480 20 2,080 7,099 2,505 24 11,700 $93,9402,160 HS 480 20 2,160 7,372 2,601 24 11,700 $95,8302,240 HS 480 20 2,240 7,645 2,697 24 11,700 $97,7502,320 HS 480 20 2,320 7,918 2,794 24 13,670 $99,7102,400 HS 480 20 2,400 8,191 2,890 24 13,670 $101,7102,480 HS 480 20 2,480 8,464 2,987 24 14,620 $103,7502,560 HS 480 20 2,560 8,737 3,083 24 14,620 $105,8302,640 HS 480 20 2,640 9,010 3,179 24 14,620 $107,9502,720 HS 480 20 2,720 9,283 3,276 24 14,620 $110,1102,800 HS 480 20 2,800 9,556 3,372 24 14,620 $112,3202,880 HS 480 20 2,880 9,829 3,468 24 14,620 $114,5702,960 HS 480 20 2,960 10,102 3,565 24 17,390 $116,8703,040 HS 480 20 3,040 10,376 3,661 32 17,390 $119,2103,120 HS 480 20 3,120 10,649 3,757 32 17,390 $121,6003,200 HS 480 20 3,200 10,922 3,854 32 17,390 $124,0403,280 HS 480 20 3,280 11,195 3,950 32 17,390 $126,5203,360 HS 480 20 3,360 11,468 4,046 32 17,390 $129,0503,440 HS 480 20 3,440 11,741 4,143 32 17,390 $131,6403,520 HS 480 20 3,520 12,014 4,239 32 17,390 $134,2803,600 HS 480 20 3,600 12,287 4,335 32 17,390 $136,960

Notes:

ALL PRICES ARE F.O.B. FACTORY AND SUBJECT TO CHANGE WITHOUT NOTICE.

1) All Lattner cabinet style electric boilers are custom designed to fit your application. They require additional engineering, quality control, and lead time. In addition, all steps are subject to change depending wattage of boiler, voltage, and specifications. Please be aware of these facts when ordering.2) One instruction manual will be provided with the boiler no charge at the time of the boiler order. One additional manual will be provided no charge at the time of the order if requested. Additional manuals or manuals requested after the boiler is shipped will be invoiced at $30 each.3) Two sets of submittals will be provided with the boiler no charge at the time of the boiler order. One additional digital (email) set of submittals will be provided no charge at the time of the order if requested. Additional submittals or submittals requested after the boiler is shipped will be invoiced at $15 each.4) Boiler start-up by a factory authorized representative may be requested for a net cost of $1400 per day plus travel and expenses. Boiler start-up cannot be scheduled until start-up request has been returned to Lattner.

ENGINEERING CHANGES, INCLUDING WIRING DIAGRAM AND EQUIPMENT SUPPLY CHANGES, MADE AFTER SUBMITTAL APPROVAL WILL BE INVOICED AT $90 (NET) PER HOUR.

24

Page 25: LIST PRICES FOR LATTNER BOILERS & ACCESSORIESlattner.com/userfiles/literature/lattner prices march 2013.pdf · Lattner Boiler Company Vertical Steam Boiler Options March 1st, 2013

Lattner Boiler CompanyCabinet Style Electric Steam Boilers (240v)

March 1st, 2013SB116

Lattner Boiler CompanyP.O. Box 15271411 9th St. SWCedar Rapids, IA 52406

Telephone: (800) 345-1527Fax: (319) 366-0770

Email: [email protected]: www.lattnerboiler.com

KW MBH Amps StepsWeight (LBS) Price (USD)

165 HS 240 4 165 563 397 6 1,475 $23,750180 HS 240 4 180 614 434 6 1,475 $24,990195 HS 240 4 195 666 470 7 1,475 $26,300210 HS 240 4 210 717 506 7 1,475 $27,680240 HS 240 4 240 819 578 8 2,400 $29,120270 HS 240 5 270 922 650 8 2,400 $30,650300 HS 240 5 300 1,024 723 8 2,400 $32,270330 HS 240 10 330 1,126 795 8 2,400 $33,960360 HS 240 10 360 1,229 867 8 2,400 $35,740390 HS 240 10 390 1,331 939 12 3,450 $37,610420 HS 240 10 420 1,433 1,012 12 3,450 $38,370450 HS 240 10 450 1,536 1,084 12 3,450 $39,140480 HS 240 10 480 1,638 1,156 12 3,750 $39,930510 HS 240 10 510 1,741 1,228 12 3,750 $40,740540 HS 240 10 540 1,843 1,301 12 3,750 $41,560570 HS 240 10 570 1,945 1,373 16 3,750 $42,400600 HS 240 10 600 2,048 1,445 16 3,750 $43,260630 HS 240 10 630 2,150 1,517 16 3,750 $44,120660 HS 240 10 660 2,253 1,590 16 3,750 $45,020690 HS 240 10 690 2,355 1,662 16 3,750 $45,920720 HS 240 10 720 2,457 1,734 16 3,750 $46,850750 HS 240 10 750 2,560 1,806 24 4,450 $47,780780 HS 240 10 780 2,662 1,879 24 4,450 $48,750810 HS 240 10 810 2,765 1,951 24 4,450 $49,730840 HS 240 10 840 2,867 2,023 24 4,450 $50,730870 HS 240 10 870 2,969 2,095 24 5,760 $51,730900 HS 240 10 900 3,072 2,168 24 5,760 $52,770930 HS 240 15 930 3,174 2,240 24 5,760 $53,840960 HS 240 15 960 3,276 2,312 24 6,320 $54,920990 HS 240 15 990 3,379 2,384 24 6,320 $56,020

1,020 HS 240 15 1,020 3,481 2,457 24 6,320 $57,1501,050 HS 240 15 1,050 3,584 2,529 24 6,320 $58,3001,080 HS 240 15 1,080 3,686 2,601 24 6,320 $59,4601,120 HS 240 15 1,120 3,823 2,697 24 6,320 $60,6501,160 HS 240 15 1,160 3,959 2,794 24 8,300 $61,8701,200 HS 240 15 1,200 4,096 2,890 24 8,300 $63,1101,240 HS 240 15 1,240 4,232 2,987 24 8,300 $64,380

Notes:

ALL PRICES ARE F.O.B. FACTORY AND SUBJECT TO CHANGE WITHOUT NOTICE.

Model:

1) All Lattner cabinet style electric boilers are custom designed to fit your application. They require additional engineering, quality control, and lead time. In addition, all steps are subject to change depending wattage of boiler, voltage, and specifications. Please be aware of these facts when ordering.2) One instruction manual will be provided with the boiler no charge at the time of the boiler order. One additional manual will be provided no charge at the time of the order if requested. Additional manuals or manuals requested after the boiler is shipped will be invoiced at $30 each.3) Two sets of submittals will be provided with the boiler no charge at the time of the boiler order. One additional digital (email) set of submittals will be provided no charge at the time of the order if requested. Additional submittals or submittals requested after the boiler is shipped will be invoiced at $15 each.4) Boiler start-up by a factory authorized representative may be requested for a net cost of $1400 per day plus travel and expenses. Boiler start-up cannot be scheduled until start-up request has been returned to Lattner.

ENGINEERING CHANGES, INCLUDING WIRING DIAGRAM AND EQUIPMENT SUPPLY CHANGES, MADE AFTER SUBMITTAL APPROVAL WILL BE INVOICED AT $90 (NET) PER HOUR.

25

Page 26: LIST PRICES FOR LATTNER BOILERS & ACCESSORIESlattner.com/userfiles/literature/lattner prices march 2013.pdf · Lattner Boiler Company Vertical Steam Boiler Options March 1st, 2013

Lattner Boiler CompanyCabinet Style Electric Steam Boilers (208v)

March 1st, 2013SB116

Lattner Boiler CompanyP.O. Box 15271411 9th St. SWCedar Rapids, IA 52406

Telephone: (800) 345-1527Fax: (319) 366-0770

Email: [email protected]: www.lattnerboiler.com

KW MBH Amps StepsWeight (LBS) Price (USD)

171 HS 208 5 171 584 475 8 1,475 $35,830188 HS 208 10 188 642 523 8 1,475 $38,030205 HS 208 10 205 700 570 8 1,475 $40,290222 HS 208 10 222 759 618 8 1,475 $42,670239 HS 208 10 239 817 665 8 2,400 $42,300257 HS 208 10 257 875 713 8 2,400 $42,410274 HS 208 10 274 934 760 8 2,400 $42,850291 HS 208 10 291 992 808 8 2,400 $43,560308 HS 208 10 308 1,051 855 8 2,400 $44,500325 HS 208 10 325 1,109 903 8 3,450 $45,630342 HS 208 10 342 1,167 950 8 3,450 $45,490359 HS 208 10 359 1,226 998 12 3,450 $45,480376 HS 208 10 376 1,284 1,045 12 3,750 $45,580393 HS 208 10 393 1,342 1,093 12 3,750 $45,750410 HS 208 10 410 1,401 1,141 12 3,750 $46,000428 HS 208 10 428 1,459 1,188 16 3,750 $46,310445 HS 208 10 445 1,517 1,236 16 3,750 $46,680462 HS 208 10 462 1,576 1,283 16 3,750 $47,090479 HS 208 10 479 1,634 1,331 16 3,750 $47,550496 HS 208 10 496 1,693 1,378 16 3,750 $48,060513 HS 208 10 513 1,751 1,426 16 3,750 $48,600530 HS 208 15 530 1,809 1,473 16 4,450 $49,190547 HS 208 15 547 1,868 1,521 16 4,450 $49,800564 HS 208 17 564 1,926 1,568 16 4,450 $50,440581 HS 208 17 581 1,984 1,616 16 4,450 $51,120599 HS 208 18 599 2,043 1,663 18 5,760 $51,840616 HS 208 18 616 2,101 1,711 18 5,760 $52,580633 HS 208 19 633 2,159 1,758 19 6,320 $53,340650 HS 208 19 650 2,218 1,806 19 6,320 $54,140667 HS 208 20 667 2,276 1,853 20 6,320 $54,960684 HS 208 20 684 2,334 1,901 20 6,320 $55,810701 HS 208 20 701 2,393 1,948 21 6,320 $56,680718 HS 208 20 718 2,451 1,996 21 6,320 $57,590752 HS 208 20 752 2,568 2,091 22 8,300 $59,340

Notes:

Model:

1) All Lattner cabinet style electric boilers are custom designed to fit your application. They require additional engineering, quality control, and lead time. In addition, all steps are subject to change depending wattage of boiler, voltage, and specifications. Please be aware of these facts when ordering.2) One instruction manual will be provided with the boiler no charge at the time of the boiler order. One additional manual will be provided no charge at the time of the order if requested. Additional manuals or manuals requested after the boiler is shipped will be invoiced at $30 each.3) Two sets of submittals will be provided with the boiler no charge at the time of the boiler order. One additional digital (email) set of submittals will be provided no charge at the time of the order if requested. Additional submittals or submittals requested after the boiler is shipped will be invoiced at $15 each.4) Boiler start-up by a factory authorized representative may be requested for a net cost of $1400 per day plus travel and expenses. Boiler start-up cannot be scheduled until start-up request has been returned to Lattner.

ENGINEERING CHANGES, INCLUDING WIRING DIAGRAM AND EQUIPMENT SUPPLY CHANGES, MADE AFTER SUBMITTAL APPROVAL WILL BE INVOICED AT $90 (NET) PER HOUR.

26

Page 27: LIST PRICES FOR LATTNER BOILERS & ACCESSORIESlattner.com/userfiles/literature/lattner prices march 2013.pdf · Lattner Boiler Company Vertical Steam Boiler Options March 1st, 2013

Lattner Boiler CompanyCabinet Style Electric Boiler Options

March 1st, 2013

Lattner Boiler CompanyP.O. Box 15271411 9th St. SWCedar Rapids, IA 52406

Telephone: (800) 345-1527Fax: (319) 366-0770

Email: [email protected]: www.lattnerboiler.com

150 250 400 600 800 1000 1200 1600 2000 2500amps amps amps amps amps amps amps amps amps amps

$1,250 $1,900 $3,570 $5,430 $5,970 $7,650 $9,460 $12,790 $16,110 $25,630

Shunt trip with door mounted operating mechanism $900Door interlock $100Ground fault detector with CT sensor and test, manual reset $1,740Energy meter, kWh, amps, voltage. Includes digital display and CT sensors $3,050Building Management System Interface and Gateway (specify protocol) $7,250Voltmeter, flush-mounted in panel $450Additional sequencer (custom element sequencing, ex. 16 steps to 24 steps) $1,150Electronic load limiter (for use with Selectronix sequencers) $250Energy saving /manual load limiting switch (per switch) $90Ammeter (1 phase), flush-mounted in panel with CT $600Ammeter (3 phase), flush-mounted in panel with CT $1,110Auxiliary high temperature control, automatic reset, mounted and wired (specify set point) $290Auxiliary low water cut-off, probe type control, with automatic reset $280Outdoor air reset control with hot water and outdoor air sensors (1:1 ratio standard) $720Local / remote selector switch $180Flow switch (packed separately) with interlock terminals $230Annunciation relays, dry contacts (per relay) $90Flanged inlet / outlet (3" or 4") $320Alarm bell (standard for low water) $250Automatic air vent (hot water boilers only) $180Remote set point adjust control (0-10 VDC) $1,400

Notes:

Disconnects (Molded Case Switch Non-Fused)

ALL PRICES ARE F.O.B. FACTORY AND SUBJECT TO CHANGE WITHOUT NOTICE.

1) All Lattner cabinet style electric boilers are custom designed to fit your application. They require additional engineering, quality control, and lead time. In addition, all steps are subject to change depending wattage of boiler, voltage, and specifications. Please be aware of these facts when ordering.2) One instruction manual will be provided with the boiler no charge at the time of the boiler order. One additional manual will be provided no charge at the time of the order if requested. Additional manuals or manuals requested after the boiler is shipped will be invoiced at $30 each.3) Two sets of submittals will be provided with the boiler no charge at the time of the boiler order. One additional digital (email) set of submittals will be provided no charge at the time of the order if requested. Additional submittals or submittals requested after the boiler is shipped will be invoiced at $15 each.4) Boiler start-up by a factory authorized representative may be requested for a net cost of $1400 per day plus travel and expenses. Boiler start-up cannot be scheduled until start-up request has been returned to Lattner.

27

Page 28: LIST PRICES FOR LATTNER BOILERS & ACCESSORIESlattner.com/userfiles/literature/lattner prices march 2013.pdf · Lattner Boiler Company Vertical Steam Boiler Options March 1st, 2013

Lattner Boiler CompanySimplex Condensate Return / Feed Water Systems

March 1st, 2013Bulletin: SB100

Lattner Boiler CompanyP.O. Box 15271411 9th St. SWCedar Rapids, IA 52406

Telephone: (800) 345-1527Fax: (319) 366-0770

Email: [email protected]: www.lattnerboiler.com

Simplex SS AdderLV5 5 9 1/2 115/1 $1,830 $610 110 14" x 33"LV8 10 16 1/2 115/1 $1,850 $610 125 14" x 43"LV16 20 32 1/2 115/1 $2,050 $910 200 18" x 51"LV20 25 32 3/4 115/1 $2,170 $880 200 18" x 51"LV20-3 25 32 3/4 220-440/3 $2,170 $880 200 18" x 51"LV25 30 46 3/4 115/1 $2,420 $1,010 205 18" x 63"LV25-3 30 46 3/4 220-440/3 $2,420 $1,010 205 18" x 63"LV35 40 46 1-1/2 220-440/3 $2,880 $1,010 205 18" x 63"LV60 60 65 3 220-440/3 $3,910 $1,230 385 24" x 63"LV75 80 80 3 220-440/3 $4,170 $1,360 405 24" x 70"LV100 100 120 5 220-440/3 $6,230 $2,200 480 28" x 71"LV150 150 150 5 220-440/3 $6,980 $2,430 480 28" x 83"

Simplex SS AdderR1-Jr. 10 16 1/2 115/1 $2,380 150 30" x 13" x 29"R1 20 32 1/2 115/1 $2,660 200 34" x 13" x 38"R2 25 32 3/4 115/1 $2,790 210 34" x 13" x 38"R2-3 25 32 3/4 220-440/3 $2,790 210 34" x 13" x 38"R3 30 42 3/4 115/1 $3,200 250 30" x 14" x 40"R3-3 30 42 3/4 220-440/3 $3,200 250 30" x 14" x 40"R5 40 42 1-1/2 220-440/3 $3,690 260 30" x 14" x 40"R7 60 55 3 220-440/3 $4,540 385 40" x 20" x 42"R10 80 120 3 220-440/3 $6,110 590 42" x 25" x 52"R12 125 120 5 220-440/3 $7,600 675 42" x 25" x 52"

$240$900

$1,300$140$150

$440$940

Notes:

Feed Water Only Options (Used when no condensate is returned):

Aluminum anode - Model AA-1 installed in tank for corrosion protection.Dial thermometer - Model DT-1 with 2" dial and 1/2" socket.

Ship Weight (LBS)

Anti-syphon float valve assemblyTank heater kit - TH5 (5 to 60 HP), thermometer, sparger, steam solenoid, sensor.Tank heater kit - TH7 (80 to 200 HP), thermometer, sparger, steam solenoid, sensor.

Options:

R Series Simplex Horizontal Return Systems

Price (USD)L x W x HModel:

Boiler (BHP) Volt.

Tank (GAL)

Pump Motor (HP)

All return systems are furnished with turbine-type pumps and motor units, water gauge sets, water make-up valves, suction strainers, shut-off valves, and piping. CAUTION: Pumps for electric boilers require separate 120/1 or 220-440/3 supply. Boiler control transformer is not sized to carry pump motor load.

LV Series Simplex Vertical Return Systems

Model:Boiler (BHP)

Tank (GAL)

Pump Motor (HP) Volt.

Price (USD)W x H

Ship Weight (LBS)

ALL PRICES ARE F.O.B. FACTORY AND SUBJECT TO CHANGE WITHOUT NOTICE.

2) For custom return systems and control packages, please consult factory.

Solenoid water valve - Model SWV-1 including strainer, stop and check valves, 1/2".Feed pump - Model 1, 115/1 motor, solenoid, and strainer for boilers smaller than 10 HP.

1) All three phase return systems include starters.

28

Page 29: LIST PRICES FOR LATTNER BOILERS & ACCESSORIESlattner.com/userfiles/literature/lattner prices march 2013.pdf · Lattner Boiler Company Vertical Steam Boiler Options March 1st, 2013

Lattner Boiler CompanyDuplex Condensate Return / Feed Water Systems

March 1st, 2013Bulletin: SB100

Lattner Boiler CompanyP.O. Box 15271411 9th St. SWCedar Rapids, IA 52406

Telephone: (800) 345-1527Fax: (319) 366-0770

Email: [email protected]: www.lattnerboiler.com

Duplex A Duplex B SS AdderLV16-D 20 32 1/2 115/1 $3,620 $3,940 $1,100 240 18" x 51"LV20-D 25 32 3/4 115/1 $3,850 $4,160 $1,070 240 18" x 51"LV20-3-D 25 32 3/4 220-440/3 $4,670 $4,860 $1,070 240 18" x 51"LV25-D 30 46 3/4 115/1 $4,140 $4,460 $1,220 245 18" x 63"LV25-3-D 30 46 3/4 220-440/3 $4,970 $5,150 $1,220 245 18" x 63"LV35-D 40 46 1-1/2 220-440/3 $5,940 $6,130 $1,220 245 18" x 63"LV60-D 60 65 3 220-440/3 $7,350 $7,530 $1,480 460 24" x 63"LV75-D 80 80 3 220-440/3 $7,650 $7,840 $1,640 490 24" x 70"LV100-D 100 120 5 220-440/3 $10,010 $10,200 $2,640 565 28" x 71"LV150-D 150 150 5 220-440/3 $10,870 $11,060 $2,920 565 28" x 83"

Duplex A Duplex B SS AdderR1-D 20 32 1/2 115/1 $4,140 $4,460 240 34" x 13" x 38"R2-D 25 32 3/4 115/1 $4,570 $4,890 250 34" x 13" x 38"R2-3-D 25 32 3/4 220-440/3 $5,270 $5,440 250 34" x 13" x 38"R3-D 30 42 3/4 115/1 $4,730 $5,040 300 30" x 14" x 40"R3-3-D 30 42 3/4 220-440/3 $5,770 $5,960 310 30" x 14" x 40"R5-D 40 42 1-1/2 220-440/3 $6,220 $6,410 320 30" x 14" x 40"R7-D 60 55 3 220-440/3 $7,030 $7,220 460 40" x 20" x 42"R10-D 80 120 3 220-440/3 $8,050 $8,240 675 42" x 25" x 52"R12-D 125 120 5 220-440/3 $9,930 $10,120 760 42" x 25" x 52"

$240$900

$1,300$150

Notes:

Tank (GAL)

Pump Motors

(HP)

R Series Duplex Horizontal Return Systems

L x W x HBoiler (BHP)

Tank (GAL)

Pump Motors

(HP)

Tank heater kit - TH5 (5 to 60 HP), thermometer, sparger, steam solenoid, sensor.Tank heater kit - TH7 (80 to 200 HP), thermometer, sparger, steam solenoid, sensor.

All return systems are furnished with turbine-type pumps and motor units, water gauge sets, water make-up valves, suction strainers, shut-off valves, and piping. CAUTION: Pumps for electric boilers require separate 120/1 or 220-440/3 supply. Boiler control transformer is not sized to carry pump motor load.

LV Series Duplex Vertical Return Systems

Price (USD)W x HVolt.

Ship Weight (LBS)Model:

Boiler (BHP)

Model:

Ship Weight (LBS)

Options:Anti-syphon float valve assembly

Price (USD)Volt.

ALL PRICES ARE F.O.B. FACTORY AND SUBJECT TO CHANGE WITHOUT NOTICE.

1) All three phase return systems include starters.

4) For custom return systems and control packages, please consult factory.

Aluminum anode - Model AA-1 installed in tank for corrosion protection.

2) Duplex A package includes NEMA-1 panel, A/B alternator, HOA switch, dial thermometer, and pump lights.3) Duplex B package includes NEMA-1 panel, A/B alternator, HOA switch, On/Off switches, non-fused disconnect, dial thermometer, and pump lights.

29

Page 30: LIST PRICES FOR LATTNER BOILERS & ACCESSORIESlattner.com/userfiles/literature/lattner prices march 2013.pdf · Lattner Boiler Company Vertical Steam Boiler Options March 1st, 2013

Lattner Boiler CompanyBlowdown Separators

March 1st, 2013Bulletin: SB111

Lattner Boiler CompanyP.O. Box 15271411 9th St. SWCedar Rapids, IA 52406

Telephone: (800) 345-1527Fax: (319) 366-0770

Email: [email protected]: www.lattnerboiler.com

Model: Vent1 Drain Height2 Weight (LBS)Blowdown Inlet Size3 Price (USD)

810 2" 2" 33-3/8" 47 Up to 1" $1,220.001450 3" 3" 53-11/16" 155 Up to 1-1/2" $1,880.0014554 2" 1" Call 250 Up to 1-1/2" $2,040.001600 6" Flg. 5" Flg. 70-3/4" 310 Up to 2" $2,250.001800 6" Flg. 6" Flg. 71" 350 Up to 2-1/2" $3,100.00

$370$510$600$650$140

$230$300$370$410

$960$1,240$1,370$1,450$140

$1,280$1,360$1,510$630$230

$1,100$3,900

Notes:

ALL PRICES ARE F.O.B. FACTORY AND SUBJECT TO CHANGE WITHOUT NOTICE.

4) Model 1455 is a blowdown tank (holds water) with leg set, not a blowdown separator.

SC-1 Sample Cooler

3) Boiler blowdown (blowdown connection) size determines separator model. DO NOT REDUCE BLOWDOWN SIZE.

1) Models 810 and 1450 include vents with threaded pipe nipples and drains with threaded couplings. Models 1600 and 1800 include flanged vents and drains.2) Overall height including leg set.

Manual Surface Blowoff

TDS/Conductivity Surface BlowoffAutomatic Surface Blowoff

- Model 205A (fits #810) 2" drain with 1/2" cooling water connection- Model 301A (fits #1450) 3" drain with 1" cooling water connection

- 3/4" and 1" blowdown valve size- 1-1/4" and 1-1/2" blowdown valve size- 2" and 2-1/2" blowdown valve size

- Model 525A (fits #1600) 5" drain with 1-1/4" cooling water connection- Model 625A (fits #1800) 6" drain with 1-1/4" cooling water connection- Model DT-2 dial thermometer for aftercooler

Automatic bottom blowdown unit w/motorized ball valve controlled by a combination interval/duration time, model 1674-B

Automatic aftercooler for blowdown separator complete with ball valve, check valve, strainer, and water regulating valve

Manual aftercooler for blowdown separator complete with ball valve, check valve, and nipples- Model 205M (fits 810) 2" drain with 1/2" cooling water connection- Model 301M (fits 1450) 3" drain with 1" cooling water connection- Model 525M (fits 1600) 5" drain with 1-1/4" cooling water connection- Model 625M (fits 1800) 6" drain with 1-1/4" cooling water connection- Model DT-2 dial thermometer for aftercooler

Condensate cooler discharge mixer pipe only- Model 205P, 2" drain- Model 301P, 3" drain- Model 525P, 5" drain- Model 625P, 6" drain

Accessories:

Blowdown Separators (Including Legs) - 150 PSI

30

Page 31: LIST PRICES FOR LATTNER BOILERS & ACCESSORIESlattner.com/userfiles/literature/lattner prices march 2013.pdf · Lattner Boiler Company Vertical Steam Boiler Options March 1st, 2013

Lattner Boiler CompanyWater Softener and Chemical Feed Systems

March 1st, 2013

Lattner Boiler CompanyP.O. Box 15271411 9th St. SWCedar Rapids, IA 52406

Telephone: (800) 345-1527Fax: (319) 366-0770

Email: [email protected]: www.lattnerboiler.com

Boiler (BHP): Grains Required5 3,72610 7,45215 11,23220 14,90425 18,68430 22,35640 29,80850 37,26060 44,71280 59,616100 74,520125 93,203150 112,320200 149,040

30 Gallon Tank 55 Gallon Tank 30 Gallon Tank 55 Gallon Tank$6,860 $7,360 $8,080 $8,550

$4,480 $8,750

Tank SizeList Price

All chemical feed systems include polyethylene tank, "V" series pump(s), stainless steel wet end, agitator, injection quill, water meter with timer, and fittings. Contact Lattner for additional control packages.

Chemical Feed SystemsSimplex (USD) Duplex (USD)Model:

$4,480 $8,750Call Call

$3,070 $8,100$3,070 $8,100$3,070 $8,100

$3,120$2,560 $3,120

$2,330 $2,770

ALL PRICES ARE F.O.B. FACTORY AND SUBJECT TO CHANGE WITHOUT NOTICE.

All water softeners include brine tank, resin tank, meter with timer, and manual bypass valve. Constructed of corrosion proof materials.

Single Tank, Simplex Price (USD) Twin Tank, Duplex Price (USD)Water Softeners

$1,560 $2,770$1,560 $2,770$1,560 $2,770$1,560 $2,770$2,330 $2,770

$2,560

31

Page 32: LIST PRICES FOR LATTNER BOILERS & ACCESSORIESlattner.com/userfiles/literature/lattner prices march 2013.pdf · Lattner Boiler Company Vertical Steam Boiler Options March 1st, 2013

Lattner Boiler CompanyState Code Requirements

March 1st, 2013

Lattner Boiler CompanyP.O. Box 15271411 9th St. SWCedar Rapids, IA 52406

Telephone: (800) 345-1527Fax: (319) 366-0770

Email: [email protected]: www.lattnerboiler.com

State RequirementArizona ASME Code piping package w/P-6 data form.

High and low water alarms on all boilers 10 HP to 150 HP.Low-NOx equipment (<20 PPM) on all boilers 3 HP and larger.

Colorado ASME Code piping package w/P-6 data form.Connecticut Additional motorized gas valve for boilers 60 HP to 150 HP.D.C. Brass piping (steam side).Hawaii Low water level alarm 5 HP to 150 HP.Indiana ASME Code piping package w/P-6 data form.Iowa ASME Code piping package w/P-6 data form.Kansas ASME Code piping package w/P-6 data form.Kentucky "U" stamp on all blowdown separators.Maryland Additional motorized gas valve for boilers 60 HP to 150 HP.

High and low gas pressure switches for 30 HP to 50 HP.Additional low water relay, manual reset for 1-1/2 HP to 10 HP.

Michigan "U" stamp on all blowdown separators.Nebraska ASME Code piping package w/P-6 data formNevada Additional low water level alarm.

Additional gas valve 60 HP to 150 HPHigh and low gas pressure switches for 30 HP to 50 HP.

Ohio ASME Code piping package w/P-6 data form.Oregon Low water level alarm.Pennsylvania Additional motorized gas valve for boilers 60 HP to 150 HP.Texas Low-NOx equipment (<30 PPM) on all boilers up to and including 49 HP.Vermont Requires McDonnell & Miller 157 primary low water cut-off.

ASME Code piping package w/P-6 data form.Additional motorized gas valve for boilers 60 HP to 150 HP.

Wisconsin ASME Code piping package w/P-6 data form.

Massachusettes

Lattner is not responsible for determining city, county, state, federal, and insurance code requirements. It is the sole responsibility of the representative, distributor, and/or customer to determine applicable boiler requirements and codes.

Virginia

New York

California

32

Page 33: LIST PRICES FOR LATTNER BOILERS & ACCESSORIESlattner.com/userfiles/literature/lattner prices march 2013.pdf · Lattner Boiler Company Vertical Steam Boiler Options March 1st, 2013

LATTNER BOILER LIMITED WARRANTY A Lattner boiler shell is guaranteed to be constructed in accordance with the ASME Code. An independent ASME boiler inspector inspects the construction of each boiler and: (1) checks mill test reports on all materials used to ensure that the chemical and physical analysis of such materials complies with the ASME Code; (2) inspects each boiler shell during construction to see that workmanship complies with the Code; and (3) witnesses the final hydrostatic test and then places the ASME stamp on the boiler shell and signs an ASME data report certifying the boiler is ASME approved. Lattner warrants the boiler and any other equipment of its manufacture to be free from defects in material and workmanship for one (1) year from the date of shipment from the factory, provided the boiler is operated under the normal use and service for which it was intended, and only if the boiler has been properly installed by a qualified technician in accordance with but not limited to ASME, ANSI, and NFPA Codes and applicable local, state, and national codes. Lattner’s obligation under this Warranty is limited, at Lattner’s option, to replacing or repairing any defective part of the boiler or other equipment it manufactures. No allowance will be made for labor, transportation, or other charges incurred in the replacement or repair of defective parts. Merchandise not manufactured by the Company, supplied in one piece or in component assemblies, is not covered by the above warranty, but the Company will give the Purchaser the benefit of such adjustment as it can make with the manufacturer of such items. Lattner shall not be liable for special, indirect, or consequential damages. Lattner shall not be liable for any loss or damage resulting, directly or indirectly, from the use or loss of use of the boiler. This exclusion from liability includes the Purchaser’s expenses for downtime or for making up downtime, damages for which the Purchaser may be liable to other persons, or damages to property. The remedies set forth in this Warranty are exclusive, and the liability of Lattner with respect to any contract or sale shall not exceed the cost of repair or replacement of the boiler or other equipment manufactured by Lattner. The above Warranty shall not apply to any boiler or other equipment manufactured by Lattner which:

1) has been repaired or altered without Lattner’s written consent; 2) has been altered in any way so as, in the judgment of Lattner, to adversely affect the stability or

reliability of the boiler; 3) has been subject to improper water treatment, scale, corrosion, misuse, negligence, or accident; 4) has not been operated in accordance with Lattner’s printed instructions or specifications; 5) has been operated under conditions more severe than or otherwise exceeding those set forth in the

specifications for such boiler; or 6) has not been properly installed by a qualified technical in accordance with but not limited to ASME,

ANSI and NFPA Codes and all applicable local, state and national codes. THIS WARRANTY IS EXPRESSLY MADE IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LATTNER MAKES NO WARRANTY OF MERCHANTABILITY OR OF FITNESS FOR ANY PARTICULAR PURPOSE. Purchaser must notify Lattner of a breach of Warranty within thirty (30) days after discovery thereof, but not later than the one-year guarantee period; otherwise, such claims shall be deemed waived. No allowance will be granted for any repairs or alterations made by Purchaser without Lattner’s prior verbal or written consent. Items returned to Lattner must be accompanied by a factory-supplied return goods authorization (RGA). Such authorization may be obtained by calling the factory at 319/366-0778 or by writing to P.O. Box 1527, Cedar Rapids, IA 52406. Lattner neither assumes nor authorizes any person to assume for it any other liability in connection with the sale or use of the boiler or other equipment manufactured by Lattner, and there are no oral agreements or warranties collateral to or affecting this Agreement.

LATTNER BOILER COMPANY Cedar Rapids, IA USA

2-98-06

33

Page 34: LIST PRICES FOR LATTNER BOILERS & ACCESSORIESlattner.com/userfiles/literature/lattner prices march 2013.pdf · Lattner Boiler Company Vertical Steam Boiler Options March 1st, 2013

STANDARD TERMS & CONDITIONS

LIMITATION ON QUOTATION Unless otherwise stated in the quotation, the quotation will remain valid for a period of thirty (30) days from the date hereof, at which time it will automatically expire unless extended by a signed document issued by the Company, from its headquarters in Cedar Rapids, IA.

EQUIPMENT SELECTION The Purchaser’s selection of sizes, types, capacities, and specifications and suitability thereof for the specific application shall be the unshared responsibility of the Purchaser or Purchaser’s representative or consultant.

PERMISSABLE VARIATIONS, STANDARDS, AND TOLERANCES Except in the particulars specified by the Purchaser and expressly agreed to in writing by the Company, all materials shall be produced in accordance with the Company’s standard practices. The Company reserves the right to deviate from tolerances and variations in the equipment without notice, provided that the substitute part(s) or deviation(s) are consistent with the usage and performance of the product.

PRICES Unless defined otherwise in the quotation, prices are F.O.B. Cedar Rapids, IA USA, exclusive of freight, storage, off-loading, installation, service, start-up, extended warranty or local delivery charges, if any.

TAXES Purchaser shall be liable for all Federal, State, and local taxes with respect to the purchase of the equipment proposed, unless exclusively exempted from any taxes and proof thereof is on file with the Company.

PAYMENT Purchaser shall pay with US funds, the full amount of the invoiced purchase price within thirty (30) days of the Company’s invoice, whether the equipment has shipped or has been delayed through no fault of the Company and subject to approved credit. Beginning thirty (30) days after the invoice date, Purchaser shall pay a late payment charge of two percent (2%) per month, which is an annual rate of 24%, on any unpaid portion of the purchase price. The Company reserves the right to revoke or modify these credit terms.

SHIPMENT Any shipping date shown in the body of the quotation or order acknowledgement, represents the Company’s approximated schedule as of the date of the quotation, and is subject to change as determined by shop loading if and when this quotation should be realized as an actual sale. The Company shall not incur any liability of any kind for failure to ship on any particular date unless a firm shipping date has been expressly agreed to by an officer of the Company, in a separate written document.

CANCELLATION AND DELAYS Subsequent to the receipt of Purchaser’s Purchase Order and the Company’s issued order acknowledgement, the Purchaser may not change or cancel the order in whole or in part without the written approval and acceptance by the Company of such cancellation or change. The Company may condition its approval of a change or cancellation upon a price change to reflect the Company’s cost to implement the change, or to offset costs incurred by the Company in order preparation, engineering, purchasing, or in actual production of the order. In the event that the Purchaser delays shipment of the equipment upon the Company’s notice to ship, the equipment shall be placed in storage at the Purchaser’s risk and expense, and shall be invoiced as if shipped.

RETURNS AND RESTOCKING Equipment may be returned to Lattner at 1411 9th Street SW, Cedar Rapids, IA 52404, only upon prior written authorization of the Company. Consent, if given, will be upon the condition the Purchaser assumes all carrier charges, responsibility for damages in transit, and a minimum

15% restocking charge, and only if the authorized material is in new and unused condition and returned within one year from original date of shipment. The credit will be based on the original invoice price or the current price; whichever is lower, less the applicable restocking charge.

SECURITY INTEREST For the purposes of securing payment, the Company may issue a lien on the equipment, for past due accounts, until such time that payment has been received in full. Upon receipt of payment in full, the Company will rescind the lien.

FORCE MAJEURE In no event shall the Company be liable for loss or damage resulting from any delay or failure to ship or other failure, loss, or damage that is the proximate result of any act of government authority, revolution, riot, civil disorder, act of war, delay or default in transportation, inability to obtain materials or facilities from normal sources, fire, flood, act of God, or any cause not within the reasonable control of the Company. The Company may, without causing a breach or incurring liability, allocate goods which are in short supply irrespective of the reasons therefore among customers in any manner which the Company in its sole discretion deems advisable. If an event occurs that is beyond the control of the Company, and that event delays the Company’s performance and causes its cost of production to increase because of the delay, the Company may pass such increased cost(s) on to the Purchaser.

DAMAGE LIMITATION Under no circumstance shall the Company be held liable for any loss of profits, down time, or any incidental or consequential damages of any kind with respect to its products or the transaction by which its products are sold.

WARRANTY AND PERFORMANCE Products shall be warranted in accordance with the Company’s standard warranty statement, form No. 2-98-R06. The Company’s warranty shall be voided by any abuse, misuse, neglect, unauthorized modification or service, lack of maintenance and service, or use not in accordance with the Company’s instructions. Warranty shall also be voided if water treatment has not been provided or by improper start-up of the equipment. The Company’s warranty statement and this paragraph contain the Company’s sole warranty and the Company makes no implied warranty, and there is no implied warranty of merchantability or fitness for any particular purpose.

SERVICE Unless otherwise noted herein, the cost of the equipment does not include service or installation. All services performed by the Company are subject to the Purchaser’s payment of the Company’s prevailing charges plus necessary travel and living expenses. Whenever service is quoted, please refer to Lattner’s Service Policy for specific details.

EXCLUSION OF OTHER TERMS This constitutes an offer on behalf of Lattner Boiler Manufacturing (the Company); to sell the goods described in the quotation, exclusively on the terms and conditions stated. Acceptance of this by the Purchaser is hereby expressly limited to these Terms and Conditions and shall be applicable to any order issued by the Purchaser unless other terms have been agreed to in a written document issued by the Company.

GOVERNING LAW The transaction with respect to the goods, which are subject hereof, shall be governed by, interpreted, and construed in accordance with the laws of the State of Iowa. The Courts in the State of Iowa will have the sole jurisdiction over any claim arising under this contract of sale.

ASSIGNMENT All sales as evidenced by the Company’s acknowledgement shall be binding upon and insure to the benefit of the Purchaser and the Company and their respective heirs, successors, or assigns.

LATTNER BOILER COMPANY

Cedar Rapids, IA USA TC06

34