Lintel Product Selector
Catnic
December 2008
December 2008
Cl/Sfb
UniclassL325:P4142
EPICF631:X442
(31.9) Hh2
87 87
Catnic is a Corus Group company. Furtherinformation can be found on the Corus website atwww.corusgroup.com
Care has been taken to ensure that this informationis accurate, but Corus Group plc, and itssubsidiaries, does not accept responsibility orliability for errors or information which is found tobe misleading.
This publication was printed by a Corus approvedsupplier that complies with ISO 9001, ISO 14001and OHSAS 18001 accreditation. Paper used isRegency Satin, which is manufactured from ECF(Elemental Chlorine Free) pulp sourced fromcertified or well managed forests and plantations,inks used are vegetable based.
Copyright 2008 Corus
www.catnic.com
CatnicPontypandy Industrial EstateCaerphillyCF83 3GLTelephone 029 2033 7900Facsimile 029 2086 7796
C03:30000:UK:11/2008
PDA8753/05
Photographs are supplied courtesy of Andersen Windows/Black Millwork,Barrington Homes, Taylor Wimpy PLC, Williams Lester Architects
85
For more information aboutthese products, please callCatnic on 029 2033 7900 for a brochure
LintelsPioneers of the steel lintel for morethan three generations with areputation for superior quality,reliability and backed by excellencein service.
Steel LintelsSpecial LintelsStainless Steel Lintels Free design service for bespoke feature lintelsFree scheduling service
SteelworkA selection of steelwork beams,columns and channels for whenloading conditions exceed ourstandard range of lintels
Universal beams Universal columnsParallel flange channels
Steel Plasterer’s BeadsPrecision engineered and simple touse to create, edges, corners andjoints that are resistant to chipping,cracking and impact damage.
Galvanised steel plaster and render beadsStainless steel plaster and render beads
PVC-U Plasterer’s Beads Light, rigid, non-corrosive, andeasy to use material, that offers a cost-effective way to create,edges, corners and joints that are resistant to chipping, cracking and impact damage.
Plaster and render beads
Expanded MetalEasy to use, versatile and perfectlyformed expanded metal productsbenefit from our long experience ofusing steel in construction.
Metal LathCoil MeshArch formers
Wall Starter KitsSTRONGHOLD Wall Starter Kitsare a simple yet effective systemfor tying new masonry walls toexisting walls.
Stainless steel wall starter kitsoffering superb corrosionresistance.PVC Coated wall starter kitsgalvanized steel for durablecorrosion resistance.
Cavity Wall TiesHigh quality stainless steel wall tiesfor ease of use and a long life.
Ties for brick to blockconstructionTies for brick to timberconstruction
QwikpostErecting a new boundary or repairing a gale-damaged fencehas never been easier with the Catnic's durable andaffordable fence support systems.
Garden fence post spikesRepair spikesBolt-down supportsConcrete-in postsPost extendersArris brackets, U-clips and Z- clips
- much more than just Lintels...
Contents
1
Catnic - The Name to Build a Reputation On
Technically Superior Leaders in Technical Innovation 4Products Regulatory authorities approval 5
Corrosion resistance 6Thermal performance 7Major features of Catnic lintels 8
Service Help when you need it 10Technical Service Package 11
Specification Guide How to select a lintel 13Product Selector 14Specification Clauses 16
Steel Lintels Cavity Wall Lintels 19Extreme Load Lintels 30Closed Eaves Lintels 33Timber Frame Lintels 35External Solid Wall Lintels 37Single Leaf Wall Lintels 40Internal Partition & Loadbearing Lintels 42Stainless Steel Lintels 45Steelwork 46
Special Lintels Standard Arch Lintels 48Bespoke Lintels 49
Accessories Soffit Cladding 65Arch Centres 66Stop Ends 67Weep Vents 68External Plaster Key 69
Installation Installing a cavity wall lintel 71Installing a lintel supporting concrete floors 73Installing a timber frame lintel 74
Technical Specifications Where to use a separate DPC 76Quality Assurance 77Technical Information 78The Environment 79Guide to safe storage and handling 80Material Specification 81Glossary of technical terms 82
32
Catnic has pioneered the steel lintelfor more than three generations anddesigns, manufactures and suppliesthe construction industry withtechnically superior products
Corus is Europe's second largest steelproducer with annual revenues ofaround £12 billion and a crude steelproduction of over 20 million tonnes,primarily in the UK and the Netherlands
Catnic was the First:
• To develop the steel lintel in the UKand the first to gain BBA Approval
• Manufacturer to employ therevolutionary two-part corrosionprotection system on its lintel as astandard offering
• To gain both BBA approval and thecoveted Kitemark to BS 5977
• To incorporate a built-in Damp ProofCourse into its lintels
• To provide a built-in plaster key
Far from just leading, Catnic in fact hasworked over the years with the BSI toestablish the standards for lintels in thiscountry, and continues to develop andinvest in improving on these standardswith its extensive range of products andunique features.
Corus comprises three operatingDivisions, Strip Products, Long Productsand Distribution & Building Systems andhas a global network of sales officesand service centres, employing around42,000 people worldwide.
Corus is a leading supplier to many ofthe most demanding markets around the world including construction,automotive, packaging, mechanical and electrical engineering, metal goods,and oil & gas. With innovation andcontinuous improvement at the heart ofits business performance, Corus aimsto create value by offering adifferentiated product range supportedby unrivalled customer service.
Corus is a subsidiary of Tata Steel, theworld's sixth largest steel producer. Witha combined presence in nearly 50countries, the Tata Steel Group includingCorus, Tata Steel Thailand and NatSteelAsia, has approximately 80,000employees across five continents and acrude steel production capacity of over 28 million tonnes.
Introduction to Catnic & Corus
Technically superior productsCatnic is committed to innovation and constantimprovement to meet the changes in building regulations
Introduction Leaders in technical innovation 4Regulatory authorities approval 5Corrosion resistance 6Thermal performance 7Major features of Catnic lintels 8
32
Catnic has pioneered the steel lintelfor more than three generations anddesigns, manufactures and suppliesthe construction industry withtechnically superior products
Corus is Europe's second largest steelproducer with annual revenues ofaround £12 billion and a crude steelproduction of over 20 million tonnes,primarily in the UK and the Netherlands
Catnic was the First:
• To develop the steel lintel in the UKand the first to gain BBA Approval
• Manufacturer to employ therevolutionary two-part corrosionprotection system on its lintel as astandard offering
• To gain both BBA approval and thecoveted Kitemark to BS 5977
• To incorporate a built-in Damp ProofCourse into its lintels
• To provide a built-in plaster key
Far from just leading, Catnic in fact hasworked over the years with the BSI toestablish the standards for lintels in thiscountry, and continues to develop andinvest in improving on these standardswith its extensive range of products andunique features.
Corus comprises three operatingDivisions, Strip Products, Long Productsand Distribution & Building Systems andhas a global network of sales officesand service centres, employing around42,000 people worldwide.
Corus is a leading supplier to many ofthe most demanding markets around the world including construction,automotive, packaging, mechanical and electrical engineering, metal goods,and oil & gas. With innovation andcontinuous improvement at the heart ofits business performance, Corus aimsto create value by offering adifferentiated product range supportedby unrivalled customer service.
Corus is a subsidiary of Tata Steel, theworld's sixth largest steel producer. Witha combined presence in nearly 50countries, the Tata Steel Group includingCorus, Tata Steel Thailand and NatSteelAsia, has approximately 80,000employees across five continents and acrude steel production capacity of over 28 million tonnes.
Introduction to Catnic & Corus
Technically superior productsCatnic is committed to innovation and constantimprovement to meet the changes in building regulations
Introduction Leaders in technical innovation 4Regulatory authorities approval 5Corrosion resistance 6Thermal performance 7Major features of Catnic lintels 8
54
Our rigid adherence to qualitycontrol and compliance is yourguarantee of technical superiority
Catnic lintels have gained the approval of the regulatoryauthorities both in the domestic and internationalmarkets. Such wide-spread comprehensive approval isan assurance to designers, specifiers and builders of thereliability and state-of-the art quality of the Catnic range
Catnic lintels are designed, manufactured and tested inaccordance with BS EN 845-2:2003
Leaders in Technical Innovation
Regulatory authorities approval
Catnic’s excellence isinternationally recognised
Material SpecificationCatnic’s Standard lintels aremanufactured from high quality gradegalvanised steel to BS EN 10327:2004DX51D & Z275, with a black colouredpolyester resin finish.
Catnic’s CXL lintels and Special lintelsare manufactured from structural gradesteel plate of grade S275 to
BS EN10025-2:2004 and hot-dipgalvanised after manufacture to BS EN ISO1461:1999.
Catnic’s Stainless steel lintels aremanufactured from Austenitic StainlessSteel (chrome nickel alloys) grade 1.4301(304) and do not require any furthercorrosion protection.
QualityCatnic are committed to quality controland is a BSI registered company withquality management systems inaccordance BS EN ISO 9001: 2000.
Thermal Performance / InsulationAll Catnic lintels for traditional externalcavity walls are supplied fully insulated.Insulation extends continuously alongthe full length of the lintel, leaving nopotential thermal bridges, and cannot be dislodged.
Structural PerformanceThe structural data published in theloading tables included in this technicalguide, was achieved in accordance with the requirements of BS 5977: Part 2:1983 and BS EN 845-2.2003.
Independent TestingExtensive testing was undertaken at the following test houses:• The University of Wales,
School of Engineering• The University of Glamorgan,
Construction Centre• Ceram Building Technology,
Stoke-on-Trent
Fire TestingCatnic lintels have been independentlytested in accordance with the relevantparts of BS476, Methods of Determinationof the Fire Resistance of LoadbearingElements of Construction.
Environment & SustainabilityCatnic are committed to protecting theenvironment by minimising the impact ofour operations and our products throughthe adoption of sustainable practices andthrough continuous improvement inenvironmental performance and control.Further details can be found on page 79.
073
Further details can be found in page 77 and full reports of relevant tests are availableon request from the Catnic Technical Services Department on 029 2033 7900.
BSI KitemarkCatnic steel lintels have been awardedthe BSI Kitemark license numberKM07234.
BBA CertificationCatnic steel lintels are certified by theBritish Board of Agrément undercertificate number 91/2638.
National House-Building Council(NHBC) Catnic steel lintels meet NHBCtechnical requirements.
Housing Association Property Mutual(HAPM)Catnic steel lintels achieve 35+ yearslife to first maintenance to HAPMrequirements.
Local Authority Building ControlCatnic steel lintels are compliant withcurrent UK Building Regulations andtherefore meet the requirements of theLABC in England and Wales.
Fully Part L CompliantCatnic steel lintels comply with Parts L1& L2 of the Building RegulationsApproved Documents.
BS 5977LICENCE No. KM07234
54
Our rigid adherence to qualitycontrol and compliance is yourguarantee of technical superiority
Catnic lintels have gained the approval of the regulatoryauthorities both in the domestic and internationalmarkets. Such wide-spread comprehensive approval isan assurance to designers, specifiers and builders of thereliability and state-of-the art quality of the Catnic range
Catnic lintels are designed, manufactured and tested inaccordance with BS EN 845-2:2003
Leaders in Technical Innovation
Regulatory authorities approval
Catnic’s excellence isinternationally recognised
Material SpecificationCatnic’s Standard lintels aremanufactured from high quality gradegalvanised steel to BS EN 10327:2004DX51D & Z275, with a black colouredpolyester resin finish.
Catnic’s CXL lintels and Special lintelsare manufactured from structural gradesteel plate of grade S275 to
BS EN10025-2:2004 and hot-dipgalvanised after manufacture to BS EN ISO1461:1999.
Catnic’s Stainless steel lintels aremanufactured from Austenitic StainlessSteel (chrome nickel alloys) grade 1.4301(304) and do not require any furthercorrosion protection.
QualityCatnic are committed to quality controland is a BSI registered company withquality management systems inaccordance BS EN ISO 9001: 2000.
Thermal Performance / InsulationAll Catnic lintels for traditional externalcavity walls are supplied fully insulated.Insulation extends continuously alongthe full length of the lintel, leaving nopotential thermal bridges, and cannot be dislodged.
Structural PerformanceThe structural data published in theloading tables included in this technicalguide, was achieved in accordance with the requirements of BS 5977: Part 2:1983 and BS EN 845-2.2003.
Independent TestingExtensive testing was undertaken at the following test houses:• The University of Wales,
School of Engineering• The University of Glamorgan,
Construction Centre• Ceram Building Technology,
Stoke-on-Trent
Fire TestingCatnic lintels have been independentlytested in accordance with the relevantparts of BS476, Methods of Determinationof the Fire Resistance of LoadbearingElements of Construction.
Environment & SustainabilityCatnic are committed to protecting theenvironment by minimising the impact ofour operations and our products throughthe adoption of sustainable practices andthrough continuous improvement inenvironmental performance and control.Further details can be found on page 79.
073
Further details can be found in page 77 and full reports of relevant tests are availableon request from the Catnic Technical Services Department on 029 2033 7900.
BSI KitemarkCatnic steel lintels have been awardedthe BSI Kitemark license numberKM07234.
BBA CertificationCatnic steel lintels are certified by theBritish Board of Agrément undercertificate number 91/2638.
National House-Building Council(NHBC) Catnic steel lintels meet NHBCtechnical requirements.
Housing Association Property Mutual(HAPM)Catnic steel lintels achieve 35+ yearslife to first maintenance to HAPMrequirements.
Local Authority Building ControlCatnic steel lintels are compliant withcurrent UK Building Regulations andtherefore meet the requirements of theLABC in England and Wales.
Fully Part L CompliantCatnic steel lintels comply with Parts L1& L2 of the Building RegulationsApproved Documents.
BS 5977LICENCE No. KM07234
‘Partial’ (or ‘Full’ Fill)Insulation
Inside face of windowhead to overlap insideface of outer wall by 30mm minimum
Lightweight plaster orplasterboard
Sealant required to front andback of window head
30 Min.
‘Partial’ (or ‘Full’ Fill)Insulation
Inside face of windowhead to overlap insideface of outer wall by 30mm minimum
30 Min.
Lightweight plaster orplasterboard
Sealant required to front andback of window head
76
Corrosion resistance Thermal performanceDuplex Corrosion Protection
Initially, Catnic standard lintels are manufactured from hot-dipped galvanised steel to BS EN 10327: 2004 of grade DX51Dplus coating type Z275.
A coating of thermal setting polyester powder is then applied byan electrostatic process, further protecting the lintel. Hightemperature curing then produces a tough durable surface highlyresistant to impact, abrasion and damage during rough on-sitehandling. This double method of protection gives Catnic lintelsinherent benefits over those offered by other manufacturers usingthe more traditional pre or postgalvanised steel techniques.
Both these processes rely on just a simple coating of zinc toprovide cathodic protection. The zinc protects the steel but isitself liable to rust with aqueous alkaline solutions leaching fromthe building fabric and therefore corrode. The famous blackcoating makes Catnic lintels instantly recognisable and providesan effective barrier against moisture or chemical attack leachedfrom the mortar and masonry.
Hot-Dipped Post Galvanised
All Catnic CXL lintels and fabricated lintels are fully submergedin a zinc bath after manufacture, to BS EN ISO 1461: 1999, fully protecting every surface, cut edge and weld with ametallurgically bonded zinc coating. The post-galvanisationprovides protection from corrosion and eliminates the need for on-site painting or maintenance. Hot-dipped Post-Galvanised lintels require a separate damp proof course,regardless of profile shape.
Stainless Steel Lintels
Catnic stainless steel lintels ensure a high degree of corrosion resistance without requiring additional protection.Manufactured from Austenitic Stainless Steel (chrome nickelalloys) grade 1.4301 (304) to BS EN10088-2-1.4301, they do not require any further corrosion protection and offerexcellent corrosion resistance combined with high ductility and strength making it suitable for schools, hospitals andparticularly aggressive environments. Stainless Steel lintelsincorporating our unique tray profile do not require a separatedamp proof course.
Open Back Lintel - Design Features
Catnic’s standard range of ‘open back’lintels are available with and withoutperforated steel base plates. The uniquedesign of the company’s ‘open back’lintels incorporate a perforated steelbase plate to help minimise coldbridging without affecting structuralperformance.
Catnic undertook its own assessmentusing a ‘two dimensional steady stateheat flow’ analysis on the full standardrange of cavity wall perforated lintelswith the window frame overlapping thecavity by 30mm.
The results confirmed that the criticaleffective conductivity value is notexceeded and that Catnic’s standard
lintels offer complete compliance withthe requirements of the ApprovedDocuments. For designs incorporatinglintels with unperforated base plates,suitable insulated lining is required.
For all applications a sealant should beprovided at front and back of thewindow frame to improve air tightness.
Fully-insulated, reducing heat lossCatnic Cavity wall lintels are suppliedfully insulated. To further minimise anythermal bridging the lintels are designedwithout a base plate or with aperforated base plate.
The combination of a fully insulatedlintel in conjunction with no base plateor perforated base plate ensures thatCatnic Lintels comply with thenecessary requirements of Part L of theBuilding Reguilations 2006 where wallsmust have a U value of no more than0.35 W/mK.
Catnic standard external wall lintelshave a linear thermal transmittance Ψ value of less than 0.21 W/mK.
Unique DesignThe perforated base plate pattern onthe underside of the lintel, helps tominimize any potential cold bridge pathwithout compromising its structuralstrength or integrity.
AccessoriesAccessories such as the Catnic CavityWeep Vent, used at 450mm centresabove the lintel will vent interstitialcondensation which is sometimesassociated with cold bridging.
Catnic design features that help reduce cold bridging by offering the following specific benefits
Built-in DPC profile
Galvanised Steel
Steel
Continuous insulation
Duplex coating
Plaster key
Post Galvanised Steel
Steel
Open Back Lintels
Stainless Steel
Continuous insulation
Plaster key
Open Back Lintels
Built-in DPC profile
Suitability of cavity wall lintels to meet the stipulatedthermal performance requirements of Part L1 & L2 of the Building Regulations Approved Document
Open Back without base plate Requirement: No restrictions on usage
Open Back with a perforated base plate Requirement: Effective conductivity value of the steel must
not exceed 30W/mK
CG style lintel CH & CX style lintel
‘Partial’ (or ‘Full’ Fill)Insulation
Inside face of windowhead to overlap insideface of outer wall by 30mm minimum
Lightweight plaster orplasterboard
Sealant required to front andback of window head
30 Min.
‘Partial’ (or ‘Full’ Fill)Insulation
Inside face of windowhead to overlap insideface of outer wall by 30mm minimum
30 Min.
Lightweight plaster orplasterboard
Sealant required to front andback of window head
76
Corrosion resistance Thermal performanceDuplex Corrosion Protection
Initially, Catnic standard lintels are manufactured from hot-dipped galvanised steel to BS EN 10327: 2004 of grade DX51Dplus coating type Z275.
A coating of thermal setting polyester powder is then applied byan electrostatic process, further protecting the lintel. Hightemperature curing then produces a tough durable surface highlyresistant to impact, abrasion and damage during rough on-sitehandling. This double method of protection gives Catnic lintelsinherent benefits over those offered by other manufacturers usingthe more traditional pre or postgalvanised steel techniques.
Both these processes rely on just a simple coating of zinc toprovide cathodic protection. The zinc protects the steel but isitself liable to rust with aqueous alkaline solutions leaching fromthe building fabric and therefore corrode. The famous blackcoating makes Catnic lintels instantly recognisable and providesan effective barrier against moisture or chemical attack leachedfrom the mortar and masonry.
Hot-Dipped Post Galvanised
All Catnic CXL lintels and fabricated lintels are fully submergedin a zinc bath after manufacture, to BS EN ISO 1461: 1999, fully protecting every surface, cut edge and weld with ametallurgically bonded zinc coating. The post-galvanisationprovides protection from corrosion and eliminates the need for on-site painting or maintenance. Hot-dipped Post-Galvanised lintels require a separate damp proof course,regardless of profile shape.
Stainless Steel Lintels
Catnic stainless steel lintels ensure a high degree of corrosion resistance without requiring additional protection.Manufactured from Austenitic Stainless Steel (chrome nickelalloys) grade 1.4301 (304) to BS EN10088-2-1.4301, they do not require any further corrosion protection and offerexcellent corrosion resistance combined with high ductility and strength making it suitable for schools, hospitals andparticularly aggressive environments. Stainless Steel lintelsincorporating our unique tray profile do not require a separatedamp proof course.
Open Back Lintel - Design Features
Catnic’s standard range of ‘open back’lintels are available with and withoutperforated steel base plates. The uniquedesign of the company’s ‘open back’lintels incorporate a perforated steelbase plate to help minimise coldbridging without affecting structuralperformance.
Catnic undertook its own assessmentusing a ‘two dimensional steady stateheat flow’ analysis on the full standardrange of cavity wall perforated lintelswith the window frame overlapping thecavity by 30mm.
The results confirmed that the criticaleffective conductivity value is notexceeded and that Catnic’s standard
lintels offer complete compliance withthe requirements of the ApprovedDocuments. For designs incorporatinglintels with unperforated base plates,suitable insulated lining is required.
For all applications a sealant should beprovided at front and back of thewindow frame to improve air tightness.
Fully-insulated, reducing heat lossCatnic Cavity wall lintels are suppliedfully insulated. To further minimise anythermal bridging the lintels are designedwithout a base plate or with aperforated base plate.
The combination of a fully insulatedlintel in conjunction with no base plateor perforated base plate ensures thatCatnic Lintels comply with thenecessary requirements of Part L of theBuilding Reguilations 2006 where wallsmust have a U value of no more than0.35 W/mK.
Catnic standard external wall lintelshave a linear thermal transmittance Ψ value of less than 0.21 W/mK.
Unique DesignThe perforated base plate pattern onthe underside of the lintel, helps tominimize any potential cold bridge pathwithout compromising its structuralstrength or integrity.
AccessoriesAccessories such as the Catnic CavityWeep Vent, used at 450mm centresabove the lintel will vent interstitialcondensation which is sometimesassociated with cold bridging.
Catnic design features that help reduce cold bridging by offering the following specific benefits
Built-in DPC profile
Galvanised Steel
Steel
Continuous insulation
Duplex coating
Plaster key
Post Galvanised Steel
Steel
Open Back Lintels
Stainless Steel
Continuous insulation
Plaster key
Open Back Lintels
Built-in DPC profile
Suitability of cavity wall lintels to meet the stipulatedthermal performance requirements of Part L1 & L2 of the Building Regulations Approved Document
Open Back without base plate Requirement: No restrictions on usage
Open Back with a perforated base plate Requirement: Effective conductivity value of the steel must
not exceed 30W/mK
CG style lintel CH & CX style lintel
98
Major features of Catnic lintels
Leading with ServiceCatnic is committed to delivering the mostcomprehensive service to architects, designers andengineers to meet any requirement for any project
Service Help where you need it 10Technical Service Package 11
Duplex Corrosion Protection System
Many Catnic lintels employ not just one but two methods of protectionagainst corrosive attack: The unique,sophisticated Duplex CorrosionProtection system.
Manufactured from hot-dippedgalvanised steel to BS EN 10327: 2004of grade DX51D & Z275 with the addedprotection of a black coloured polyesterresin finish. The protection systemcomplies fully with the chemical andphysical test requirements outlined inTable 2 of BS 5977:PART 2:1983 andtable C.1 of BS EN845-2:2003 for lintelseffectively having their own built-inDamp Proof Course (DPC).
The famous black coating makesCatnic lintels instantly recognisable andprovides an effective barrier againstmoisture or chemical attack leachedfrom the mortar and masonry.
Built-in Damp Proof CourseMany Catnic lintels offer a
unique profile shape that combinewith the unique Duplex CorrosionProtection or Stainless Steel to createan effective barrier that acts as a built-in DPC meaning any water penetratinginto the cavity automatically transfersacross the sloping face of the lintel and is disposed of externally.
The ease of brick laying directly ontoa solid surface eliminates the risk ofdamage while installing, or anypossibility of incorrectly installing, aseparate DPC membrane. The result is an aesthetically pleasing, clean-linefinish above the window head thatsaves time and cost. In areas ofsheltered to medium exposed weatherconditions there is no need to install a separate DPC.*
Integral Plaster KeyMany Catnic lintels come
complete with an integral plasterkey that avoid the hazards of workingwith a mesh key. In addition the uniquedesign of the perforated base plates onCH/CX lintels minimise cold bridgingwithout affecting the structuralperformance.
Continuous InsulationMany Catnic lintels are supplied
with CFC & HCFC free insulationmaximising their thermal efficiency andcompliance with Part L.
The insulation is accurately shaped to optimise the thermal performanceextending continuously along the fulllength of the lintel and cannot bedislodged, leaving no potential ‘cold spots’.
Catnic lintels offer many benefits to specifiers and buildersthrough a combination of their design, thermal efficiency
and corrosion protection. These major features ensure that Catnic lintels are widely used, and respected,
throughout the building industry
Built-in DPC profile
Galvanised Steel
Steel
Continuous insulation
Duplex coating
Plaster key
Open Back Lintels
* NHBC & Zurich Municipal technical requirementsdemand a separate DPC for severe exposure zonesas determined by BS 8104. For further details referto Where to use a Separate DPC on page 76.
9
Leading with ServiceCatnic is committed to delivering the mostcomprehensive service to architects, designers andengineers to meet any requirement for any project
Service Help when you need it 10Technical Service Package 11
11
Catnic is committed to providing thebuilding industry with new and improvedproducts, borne from investment indesign and manufacturing technologies.
Catnic means:• The strongest brand in the industry• A partnership approach to the way we
work• Dedicated haulier - liveried lorries• Servicing builders, architects,
specifiers and merchants • Committed to both national and
independent merchants• Investment in plant and machinery and
the latest technologies• Continuously dedicated to research
and development of the industry andour product offering
Catnic’s sales and technical teams arededicated to matching the quality of ourproducts with the excellence of ourservice, from the professional voice atthe end of the telephone to our on-siteconsultation.
Full service support for customersCatnic has been at the forefront of linteldesign for over 35 years. Our reputationfor exceptional quality and technicalexpertise has ensured customerssatisfaction and loyalty in the productsand services that we offer.
Catnic’s team:• Are professional and experienced• Are extensively trained• Have comprehensive product and
industry knowledge• Have a committed parent company
who are Investors in People – Corus.
10
Help When You Need It Fully committed to providingfirst class service support
The Catnic service package includes:• Experienced and dedicated team of
lintel sales representatives• Fully trained, professional internal
customer support team for all yourneeds; from placing orders, toenquiring about prices or deliveries
• Comprehensive range of back-upliterature
• On-line help via Catnic.com• CAD details available on-line providing
instant access to lintel drawings
• Technical enquiry forms toaccompany your drawings ensuringnecessary information is received andturned around in a timely manner
• On-site sales and technical supportwhen required
• Technical hotline for all queries• Dedicated hauliers for all your deliveries• Consultation at every stage of your job• Lintel scheduling and specification
via CLASS
• Next day delivery available onselected items
• Extensive range of standard andbespoke lintels
Technical supportExperienced engineers qualified inconstruction enable Catnic to offer anadvisory service to anyone engaged onbuilding projects, regardless of size,from a private house extension, to amajor housing development orcommercial building.
Free scheduling serviceCLASS – The Catnic Lintel AdvancedScheduling System is the mostcomprehensive, enviable lintelscheduling service available. Oneconcise document leaves no room for confusion or misunderstanding.CLASS clearly provides:• A description of each lintel, its
location, price and delivery time• Guaranteed structural adequacy• A site summary
To access the benefits of CLASS free of charge, simply send your projectdrawings (dimensional plans, sectionsand elevations), floor layout and roofcarcass, (along with a copy of thetechnical enquiry form in the back of this Product Selector) to our Technical team.
Design service for bespoke lintelsIn addition to its standard range, Catnicdesign and manufacture a huge range of ‘specials’. The bespoke range isdesigned and fabricated to satisfyfeatures such as long spans, chamferedbrickwork, reduced toe lintels for cantbricks, arched openings and otherapplications where non-standardconstruction is utilised. For furtherinformation please turn to page 46 of this guide.
Telephone Technical Services on
029 2033 7900
Unsurpassed technical service and support fromour experienced, helpful and friendly team
Technical Service Package
Terms and conditions
apply
NEXTDAYDELIVERYAVAILABLE
11
Catnic is committed to providing thebuilding industry with new and improvedproducts, borne from investment indesign and manufacturing technologies.
Catnic means:• The strongest brand in the industry• A partnership approach to the way we
work• Dedicated haulier - liveried lorries• Servicing builders, architects,
specifiers and merchants • Committed to both national and
independent merchants• Investment in plant and machinery and
the latest technologies• Continuously dedicated to research
and development of the industry andour product offering
Catnic’s sales and technical teams arededicated to matching the quality of ourproducts with the excellence of ourservice, from the professional voice atthe end of the telephone to our on-siteconsultation.
Full service support for customersCatnic has been at the forefront of linteldesign for over 35 years. Our reputationfor exceptional quality and technicalexpertise has ensured customerssatisfaction and loyalty in the productsand services that we offer.
Catnic’s team:• Are professional and experienced• Are extensively trained• Have comprehensive product and
industry knowledge• Have a committed parent company
who are Investors in People – Corus.
10
Help When You Need It Fully committed to providingfirst class service support
The Catnic service package includes:• Experienced and dedicated team of
lintel sales representatives• Fully trained, professional internal
customer support team for all yourneeds; from placing orders, toenquiring about prices or deliveries
• Comprehensive range of back-upliterature
• On-line help via Catnic.com• CAD details available on-line providing
instant access to lintel drawings
• Technical enquiry forms toaccompany your drawings ensuringnecessary information is received andturned around in a timely manner
• On-site sales and technical supportwhen required
• Technical hotline for all queries• Dedicated hauliers for all your deliveries• Consultation at every stage of your job• Lintel scheduling and specification
via CLASS
• Next day delivery available onselected items
• Extensive range of standard andbespoke lintels
Technical supportExperienced engineers qualified inconstruction enable Catnic to offer anadvisory service to anyone engaged onbuilding projects, regardless of size,from a private house extension, to amajor housing development orcommercial building.
Free scheduling serviceCLASS – The Catnic Lintel AdvancedScheduling System is the mostcomprehensive, enviable lintelscheduling service available. Oneconcise document leaves no room for confusion or misunderstanding.CLASS clearly provides:• A description of each lintel, its
location, price and delivery time• Guaranteed structural adequacy• A site summary
To access the benefits of CLASS free of charge, simply send your projectdrawings (dimensional plans, sectionsand elevations), floor layout and roofcarcass, (along with a copy of thetechnical enquiry form in the back of this Product Selector) to our Technical team.
Design service for bespoke lintelsIn addition to its standard range, Catnicdesign and manufacture a huge range of ‘specials’. The bespoke range isdesigned and fabricated to satisfyfeatures such as long spans, chamferedbrickwork, reduced toe lintels for cantbricks, arched openings and otherapplications where non-standardconstruction is utilised. For furtherinformation please turn to page 46 of this guide.
Telephone Technical Services on
029 2033 7900
Unsurpassed technical service and support fromour experienced, helpful and friendly team
Technical Service Package
Terms and conditions
apply
NEXTDAYDELIVERYAVAILABLE
13 1312
How to Select a Lintel
You need to know 3 things:1 The wall construction2 The length of lintel required3 The load to be applied on the lintel
Guide to SpecificationCatnic is committed to assist you in selecting the right Catnic product for the job
Specification How to select a lintel 13Product Selector 14Specification Clauses 16
Applied LoadAll lintels are designed to carry aspecific safe working load (SWL).
If you are not skilled in the methodof load assessment, or the load hasnot been supplied to you by a thirdparty, for advice please contact:
Lintel LengthThe length of lintel required iscalculated by establishing the totalwidth of the structural opening andadding 150mm (200mm for CXL lintels)end bearing allowance for each end.
For example, an 1800mm structuralopening will require a 2100mm lintel(2200mm for CXL).
Wall ConstructionOnce you have determined your wall construction please refer to the lintel selector overleaf
Once you have establishedeach of the above, you willbe able to choose thecorrect lintel for your jobby referring to the relevanttables in this guide
Cavity WallIf the construction is a cavitywall, see the Open Back lintelsection on page 19. You willneed to know the cavity walldimensions to choose thecorrect lintel: • the external leaf
dimension• the cavity dimension
including insulation• the internal leaf dimension
Timber FrameFor timber frameconstructions, you need to know:• the external leaf
dimension• cavity dimension
Once you have thesedimensions, please refer tothe Timber Frame lintelssection on page 35.
External Solid WallThere are three forms oflintel for external solid walls: • single element lintels for a
single leaf of brickwork • two-piece lintels shaped
to carry the two separateleaves of a 215mm fairface brick wall
• box profile lintels whichhave a toe for use in solidbrick or block walls from200mm – 215mm thick
Lintels suitable for use inexternal solid wallconstructions can be foundon page 37.
Internal Partition and Load Bearing Wall Lintels for internal partitionsand load bearing wallscome in three styles:• corrugated lintels for non-
load bearing applications• channel section lintels
for loadings involvingblockwork and floor joists
• box profile lintels forheavier loads includingpoint loads and wideropenings. These lintelsare featured on page 42.
1
2
3Telephone CatnicTechnical Services on
029 2033 7900
13 1312
How to Select a Lintel
You need to know 3 things:1 The wall construction2 The length of lintel required3 The load to be applied on the lintel
Guide to SpecificationCatnic is committed to assist you in selecting the right Catnic product for the job
Specification How to select a lintel 13Product Selector 14Specification Clauses 16
Applied LoadAll lintels are designed to carry aspecific safe working load (SWL).
If you are not skilled in the methodof load assessment, or the load hasnot been supplied to you by a thirdparty, for advice please contact:
Lintel LengthThe length of lintel required iscalculated by establishing the totalwidth of the structural opening andadding 150mm (200mm for CXL lintels)end bearing allowance for each end.
For example, an 1800mm structuralopening will require a 2100mm lintel(2200mm for CXL).
Wall ConstructionOnce you have determined your wall construction please refer to the lintel selector overleaf
Once you have establishedeach of the above, you willbe able to choose thecorrect lintel for your jobby referring to the relevanttables in this guide
Cavity WallIf the construction is a cavitywall, see the Open Back lintelsection on page 19. You willneed to know the cavity walldimensions to choose thecorrect lintel: • the external leaf
dimension• the cavity dimension
including insulation• the internal leaf dimension
Timber FrameFor timber frameconstructions, you need to know:• the external leaf
dimension• cavity dimension
Once you have thesedimensions, please refer tothe Timber Frame lintelssection on page 35.
External Solid WallThere are three forms oflintel for external solid walls: • single element lintels for a
single leaf of brickwork • two-piece lintels shaped
to carry the two separateleaves of a 215mm fairface brick wall
• box profile lintels whichhave a toe for use in solidbrick or block walls from200mm – 215mm thick
Lintels suitable for use inexternal solid wallconstructions can be foundon page 37.
Internal Partition and Load Bearing Wall Lintels for internal partitionsand load bearing wallscome in three styles:• corrugated lintels for non-
load bearing applications• channel section lintels
for loadings involvingblockwork and floor joists
• box profile lintels forheavier loads includingpoint loads and wideropenings. These lintelsare featured on page 42.
1
2
3Telephone CatnicTechnical Services on
029 2033 7900
Cavity Wall Lintels
page 47
page 41
Single Leaf Lintels
Light DutyCNZ94A
Standard DutyCNZ94C
Standard DutyCNZ95C
Standard DutyCNZ96C
Standard DutyCNZ97C
Heavy DutyCNZ97D
Standard DutyCN48C
Standard DutyCN49C
Heavy DutyCN49D
With over 10,000 variations available to choose from, there’s a design to suit anysize, shape, length, breadth and depth of doorway, archway, window or aperture.
www.catnic.com
page 24page 22page 20
page 25page 23page 21
page 36page 34
Standard DutyCG50/125
Heavy DutyCH50/125
Extra Heavy DutyCX50/125
100 48 95 100 48 95
Continuous solid infill
block
100 48 95
Continuous solid infill
block
100 68 95 100 68 95
Continuous solid infill
block
100 68 95
Continuous solid infill
block
100 88 95 100 88 95
Continuous solid infill
block
100 88 95
Continuous solid infill
block
Continuous solid infill
block
125 48 95 125 68 95
Continuous solid infill
block
125 88 95
Continuous solid infill
block
125 48 95
Continuous solid infill
block
125 48 95 125 68 95 125 68 95
Continuous solid infill
block
125 88 95 125 88 95
Continuous solid infill
block
100 48 60
h
100 88 60
h
100 75
143
100 75
143
47 95
h
67 95
h
h
90 95 38 95
h
Product Selector
Wide Inner Leaf Cavity Wall Lintels
90-105mm Cavity Wall – 125-140mm WIL
Standard DutyCG70/125
Heavy DutyCH70/125
Extra Heavy DutyCX70/125
Standard DutyCG90/125
Heavy DutyCH90/125
Extra Heavy DutyCX90/125
50-65mm Cavity Wall – 125-140mm WIL 70-85mm Cavity Wall – 125-140mm WIL
50-85mm Cavity 90-105mm Cavity 50-75mm Cavity
Standard DutyCGE50/100
Standard DutyCGE90/100
Heavy DutyCN55A
Extra Heavy DutyCN55C
Closed Eaves Cavity Wall Lintels
50-60mmCavity 70-80mmCavity 90-100mmCavity 35-60mm Cavity
Standard DutyCTF5
Standard DutyCTF7
Standard DutyCTF9
Heavy DutyCN23B
Heavy DutyCN23C
Timber Frame Cavity Wall Lintels
14
91
h
94
h
100
55
h
95
70
h
102mm Exterior Solid Wall 102mm Exterior Solid Wall
Special Lintels
Standard DutyCG50/100
Heavy DutyCH50/100
Extra Heavy DutyCX50/100
Standard DutyCG70/100
Heavy DutyCH70/100
Extra Heavy DutyCX70/100
Standard DutyCG90/100
Heavy DutyCH90/100
Extra Heavy DutyCX90/100
Standard Arch Lintels
Bespoke Arch Lintels
Bay WindowLintels
Corner Lintels
50-100mm Cavity Wall Any Wall Construction
90-105mm Cavity Wall50-65mm Cavity Wall 70-85mm Cavity Wall
08 Catnic Brochure FEB 09:Layout 1 04/02/2009 10:45 Page 14
Extreme DutyCXL240
Extreme DutyCXL265
Extreme DutyCXL290
Extreme DutyCXL310
Extreme DutyCXL330
Extreme DutyCXL350
page 44
Can’t find what you’re looking for? Contact Catnic Technical Services on 029 2033 7900
100 50 130 100 70 130 100 90 140
page 38
h
100 95100 95
143
15
A lintel for every application
200 & 215mm Solid Walls
Standard DutyCN71A
Heavy DutyCN71C
Standard DutyCN81B
Heavy DutyCN81C
Heavy DutyCN99/394C
Standard DutyCN50C
Standard DutyCN51C
External Solid Wall Lintels
182
h
215mm Fairface Brick Wall
page 4375mm Solid Wall
Extra Light DutyCN92
Extra Light DutyCN102
Light DutyCN100
Standard DutyCN5XA
Heavy DutyCN5XC
Standard DutyCN6XB
Heavy DutyCN6XC
Extra Heavy DutyCN99/438C
Standard DutyCN56XA
Heavy DutyCN66XC
Extra Heavy DutyCN99/436C
Internal Solid Wall Lintels
page 28page 27page 26
page 31page 29
100 108 95 100 128 95 100 128 95
Continuoussolid infill
block
100 128 95
Continuoussolid infill
block
100 148 95 100 148 95
Continuoussolid infill
block
100 148 95
Continuoussolid infill
block
100 108 95
Continuoussolid infill
block
100 108 95
Continuoussolid infill
block
240
236
6
133
6
133
265
259
6
133
290
284
6
133
310
304
6
133
350
344
6
133
330
324
50mmCavity 70mmCavity 90mmCavity 110mmCavity 130mmCavity 150mmCavity
Standard DutyCN42C
Standard DutyCN99/124C
Standard DutyCN99/1644C
Cavity Wall Lintels
150-165mm Cavity Wall
Standard DutyCG110/100
Heavy DutyCH110/100
Extra Heavy DutyCX110/100
Standard DutyCG130/100
Heavy DutyCH130/100
Extra Heavy DutyCX130/100
Standard DutyCG150/100
Heavy DutyCH150/100
Extra Heavy DutyCX150/100
110-125mm Cavity Wall 130-145mm Cavity Wall
Wide Outer Leaf Cavity Wall Lintels Extreme Loading Cavity Wall Lintels
50mm Cavity Wall140-150mm WOL
75mm Cavity Wall140-150mm WOL
100mm Cavity Wall140-150mm WOL
page 64Corrosion protection Aesthetics Moisture Control Moisture Control Aesthetics
Accessories
SoffitCladding
ArchCentres
Stop Ends Weep Vents ExternalPlaster Key
Terms and conditions
apply
NEXTDAYDELIVERY
AVAILABLE
68
25
98
25
103
h
100
h
140
h
100mm Solid Wall100mm Solid Wall 140-150mm Solid Wall
08 Catnic Brochure FEB 09:Layout 1 04/02/2009 10:46 Page 15
1716
Steel Lintels Stainless Steel Lintels
Specification Clauses
Steel Lintels Stainless Steel LintelsCavity Walls Provide insulated steel lintel with built indamp proof course and integral plasterkey, manufactured and designed inaccordance with BS EN 845-2:2003.
Product reference: Catnic CG… or CH… or CX…
Material: DX51D & Z275 galvanised steel coated with Duplex CorrosionProtection system.
Installation: Bed on mortar with a minimum 150mmbearing at each end. Raise inner andouter leaves of masonry together.
Timber FrameProvide steel lintel with built in damp proof course, manufactured and designed in accordance with BS EN 845-2:2003.
Product reference: Catnic CTF… or CN23….
Material:DX51D & Z275 galvanised steel coated with Duplex CorrosionProtection system.
Installation: Bed on mortar with a minimum 150mmbearing at each end. Install pinch battenand restraint clips to the timber frameas per manufacturer’s instructions. Propand laterally restrain the lintel duringconstruction.
Single Leaf WallsProvide steel lintel with built in damp proof course, manufactured and designed in accordance with BS EN 845-2:2003.
Product reference: Catnic CNZ… or CN48… or CN49…
Material:DX51D & Z275 galvanised steel coated with Duplex CorrosionProtection system (CN48, CN49) orS250GD & Z600 galvanised steel (CNZ).
Installation: Bed on mortar with a minimum 150mmbearing at each end. When installing themasonry the lintels must be proppedand laterally restrained duringconstruction.
Provide insulated steel lintels withDuplex Corrosion Protection system,manufactured and designed inaccordance with BS EN 845-2:2003.
Product reference: Catnic C…
Material: DX51D & Z275 galvanisedsteel coated with Duplex CorrosionProtection system or DX51D Z600galvanised steel
Installation: Bed on mortar with a minimum 150mmbearing at each end. Raise inner andouter leaves of masonry together whilstpropping and laterally restraining thelintel during construction.
Cavity WallsProvide insulated stainless steel lintelwith built in damp proof course andintegral plaster key, manufactured anddesigned in accordance with BS EN845-2:2003
Product reference: Catnic C…
Material:Austenitic Stainless Steel grade 304S15to BS EN 10088-2-1.4301.
Installation: Bed on mortar with a minimum 150mmbearing at each end. Raise inner andouter leaves of masonry together.
• Lintel Stop EndsProvide lintel Stop Ends to cavity walllintels.
Product reference: Catnic CL3 or C90
Installation: Insert lintel Stop Ends to suit lintelprofiles on either end of the lintel.Position in the nearest perpend at/orbeyond the end of the opening.
• Lintel Cavity Weep VentsProvide lintel Cavity Weep Vents tocavity wall lintels.
Product reference: Catnic WV… colour…
Installation: Insert lintel Cavity Weep Vents (ref:Catnic WV… colour…) at 450mmcentres. At least two per opening to beinstalled.
• Lintel Arch CentreProvide HIPS Arch Centre.
Product reference: Catnic Arch Centre ACA… or ACB…
Installation: Install Arch Centre inaccordance with manufacturer’s fixinginstructions.
• Lintel Soffit CladdingProvide PVCu lintel Soffit Cladding.Install lintel Soffit Cladding
Product reference: Catnic RC for Rebated Cavity Walllintels, or FC for Standard Cavity Wallsand colour)
Installation: Install lintel soffit claddingin accordance with manufacturer’sinstructions.
Lintel AccessoriesOther Applications
17
Stainless Steel Lintels
Stainless Steel LintelsCavity WallsProvide insulated stainless steel lintelwith built in damp proof course andintegral plaster key, manufactured anddesigned in accordance with BS EN845-2:2003
Product reference: Catnic C…
Material:Austenitic Stainless Steel grade 304S15to BS EN 10088-2-1.4301.
Installation: Bed on mortar with a minimum 150mmbearing at each end. Raise inner andouter leaves of masonry together.
• Lintel Stop EndsProvide lintel Stop Ends to cavity walllintels.
Product reference: Catnic CL3 or C90
Installation: Insert lintel Stop Ends to suit lintelprofiles on either end of the lintel.Position in the nearest perpend at/orbeyond the end of the opening.
• Lintel Cavity Weep VentsProvide lintel Cavity Weep Vents tocavity wall lintels.
Product reference: Catnic WV… colour…
Installation: Insert lintel Cavity Weep Vents (ref:Catnic WV… colour…) at 450mmcentres. At least two per opening to beinstalled.
• Lintel Arch CentreProvide HIPS Arch Centre.
Product reference: Catnic Arch Centre ACA… or ACB…
Installation: Install Arch Centre in accordance withmanufacturer’s fixing instructions.
• Lintel Soffit CladdingProvide PVCu lintel Soffit Cladding.Install lintel Soffit Cladding
Product reference: Catnic RC for Rebated Cavity Walllintels, or FC for Standard Cavity Wallsand colour)
Installation: Install lintel soffit claddingin accordance with manufacturer’sinstructions.
Lintel Accessories
18
Steel Lintel ProductsCatnic is committed to offering brand leading steellintels to suit any size, shape, length, breadth anddepth of doorway, archway, window and aperture
Steel Lintels Cavity Wall Lintels 19Extreme Load Lintels 30Closed Eaves Lintels 33Timber Frame Lintels 35External Solid Wall Lintels 37Single Leaf Wall Lintels 40Internal Partition & Loadbearing Lintels 42Stainless Steel Lintels 45Steelwork 46
Cavity Wall Lintels
Open Back Lintels
NOTE: Whilst the above information is intended to offergeneral guidance regarding typical applications, it shouldnot be considered as comprehensive. Requirements notfully covered by the above should be referred to ourtechnical services department for individual consideration.
Typical Catnic Cougar lintel over a timber window
CH & CX
As CG plus:• Supports concrete floors• Attic truss loads• Larger span multiple truss loads
Conditions of use• Nominal 150mm end bearings• Both leaves are raised together• One course of block prior to
installation of floor/roof• Refer to ‘Installing a cavity wall lintel’
(page 71)
Note:For a definition of these terms see theGlossary of Technical Terms on page 82.
Benefits
Easy-to-use open back profileAllows masonry to be built upcontinuously on both outer and inner leaf
Materials used in LintelsThe CG, CH and CX ranges are formedfrom galvanised steel, then powdercoated
Duplex corrosion protectionEnsures optimum durability andlongevity
Built-in DPCSaves time in construction, and meanscavity is easy to clean without risk ofdamage to DPC (refer to page 76)
Built-in plaster keyWith staggered slots applied to the innerflange and ribbed underside of insulation(perforated steel baseplate on CH andCX range)
Integral insulationMaximising thermal efficiency,minimising cold bridging
AccessoriesArchCentres, Stop Ends, Cavity WeepVents, Soffit Cladding (refer to page 64)
CG
• Triangulated masonry load• Supporting uniformly distributed
masonry load• Supporting uniformly distributed
timber floor and roof loads• Suitable for fair faced inner leaf
masonry
19
Two Styles are available for use in cavity wall construction:Catnic 'Cougar Open Back' lintels and CH & CX lintelsincorporate insulation, built in plaster key and built in DPC
18
Steel Lintel ProductsCatnic is committed to offering brand leading steellintels to suit any size, shape, length, breadth anddepth of doorway, archway, window and aperture
Steel Lintels Cavity Wall Lintels 19Extreme Load Lintels 30Closed Eaves Lintels 33Timber Frame Lintels 35External Solid Wall Lintels 37Single Leaf Wall Lintels 40Internal Partition & Loadbearing Lintels 42Stainless Steel Lintels 45Steelwork 46
Cavity Wall Lintels
Open Back Lintels
NOTE: Whilst the above information is intended to offergeneral guidance regarding typical applications, it shouldnot be considered as comprehensive. Requirements notfully covered by the above should be referred to ourtechnical services department for individual consideration.
Typical Catnic Cougar lintel over a timber window
CH & CX
As CG plus:• Supports concrete floors• Attic truss loads• Larger span multiple truss loads
Conditions of use• Nominal 150mm end bearings• Both leaves are raised together• One course of block prior to
installation of floor/roof• Refer to ‘Installing a cavity wall lintel’
(page 71)
Note:For a definition of these terms see theGlossary of Technical Terms on page 82.
Benefits
Easy-to-use open back profileAllows masonry to be built upcontinuously on both outer and inner leaf
Materials used in LintelsThe CG, CH and CX ranges are formedfrom galvanised steel, then powdercoated
Duplex corrosion protectionEnsures optimum durability andlongevity
Built-in DPCSaves time in construction, and meanscavity is easy to clean without risk ofdamage to DPC (refer to page 76)
Built-in plaster keyWith staggered slots applied to the innerflange and ribbed underside of insulation(perforated steel baseplate on CH andCX range)
Integral insulationMaximising thermal efficiency,minimising cold bridging
AccessoriesArchCentres, Stop Ends, Cavity WeepVents, Soffit Cladding (refer to page 64)
CG
• Triangulated masonry load• Supporting uniformly distributed
masonry load• Supporting uniformly distributed
timber floor and roof loads• Suitable for fair faced inner leaf
masonry
19
Two Styles are available for use in cavity wall construction:Catnic 'Cougar Open Back' lintels and CH & CX lintelsincorporate insulation, built in plaster key and built in DPC
Note: To achieve the ‘CH & CX’ loadingfigures indicated, lintels must be built-inas illustrated, ensuring that theblockwork infill is well-jointed duringconstruction and compatible with thestrength of the masonry above.
* For CG lintels used with 140mmdense blocks please refer to“Installing a Cavity Wall Lintel’ on page 72
Cavity Wall Lintels
Standard Duty
Heavy Duty
Extra Heavy Duty
2120
CG50/100
Standard lengths (mm) 900-1500 1800 2100 2400 2700 3000-3600
SWL 1:1/3:1 (kN) 15 18 20 22 26 26
Weight (kg/m) 5.8 7.3 8.0 8.6 9.8 12.3
Nominal height ‘h’ (mm) 140 140 160 180 220 220
Standard lengths (mm) 900-1800 1950-2100 2250-2400
SWL 1:1/19:1 (kN) 32 48 45
Weight (kg/m) 10.5 13.1 13.1
Nominal height ‘h’ (mm) 157 157 157
CH50/100
CX50/100
Note: To achieve the ‘CH & CX’ loadingfigures indicated, lintels must be built-inas illustrated, ensuring that theblockwork infill is well-jointed duringconstruction and compatible with thestrength of the masonry above.
All ratios are shown inner to outer
All ratios are shown inner to outer
All ratios are shown inner to outer
Standard lengths (mm) 900-2700 2850-3000 3300-3900 4200-4800
SWL 1:1/19:1 (kN) 60 55 50 32
Weight (kg/m) 16.0 16.0 19.4 19.4
Nominal height ‘h’ (mm) 232 232 232 232
Open Back Lintels• For 50-65mm cavity • 100-115mm inner leaf
Standard lengths are available in 150mm increments up to 3000mm, 300mm at lengths3000mm - 4800mm (including 4575mm, but excluding 4500mm).
The SWL (safe working load) is based on the total UDL (uniform distributed load) overmaximum span using 150mm end bearings.
Standard lengths are available in 300mm increments.
Standard lengths are available in 150mm increments.
Standard lengths are available in 150mm increments up to 3000mm, 300mm at lengths3000mm - 4800mm (including 4575mm, but excluding 4500mm).
The SWL (safe working load) is based on the total UDL (uniform distributed load) overmaximum span using 150mm end bearings.
Standard lengths are available in 300mm increments.
Standard lengths are available in 150mm increments.
Concrete Floor LoadsWhen using the Catnic CH and CX Open Back ranges with concrete floors, always ensurethat the blockwork is built tight against the inner vertical face of the lintel, and that a mortarjoint is added to the top of the blockwork so that the floor units have an even spread overthe inner flange of the lintel. For guidance on installation refer to page 73.
Standard lengths (mm) 900-1800 1950-2100 2250-2400
SWL 1:1/19:1 (kN) 32 48 45
Weight (kg/m) 10.7 13.4 13.4
Nominal height ‘h’ (mm) 157 157 157
CH50/125
Cavity Wall Lintels
Standard Duty
Heavy Duty
Extra Heavy Duty
• For 50-65mm cavity • 125-140*mm wide inner leaf
CG50/125*
Standard lengths (mm) 900-1200 1500-1800 2100-2400 2700-3000
SWL 1:1/3:1 (kN) 12 17 20 26
Weight (kg/m) 6.3 7.8 9.0 12.9
Nominal height ‘h’ (mm) 140 140 180 220
Concrete Floor LoadsWhen using the Catnic CH and CX Open Back ranges with concrete floors, always ensurethat the blockwork is built tight against the inner vertical face of the lintel, and that a mortarjoint is added to the top of the blockwork so that the floor units have an even spread overthe inner flange of the lintel. For guidance on installation refer to page 73.
All ratios are shown inner to outer
All ratios are shown inner to outer
All ratios are shown inner to outer
Open Back Lintels
48100 95
h
125 48 95
h
125 48 95
hContinuoussolid infill
block
125 48 95
hContinuoussolid infill
block
100 48 95
hContinuoussolid infill
block
100 48 95
hContinuoussolid infill
block
CX50/125
Standard lengths (mm) 900-2700 2850-3000 3300-3900 4200-4800
SWL 1:1/19:1 (kN) 60 55 50 32
Weight (kg/m) 16.2 16.2 19.8 19.8
Nominal height ‘h’ (mm) 232 232 232 232
Where CH & CX lintels are required tosupport greater loads than the figurespublished please contact our TechnicalServices Department on 029 2033 7900.
Where CH & CX lintels are required tosupport greater loads than the figurespublished please contact our TechnicalServices Department on 029 2033 7900.
Note: To achieve the ‘CH & CX’ loadingfigures indicated, lintels must be built-inas illustrated, ensuring that theblockwork infill is well-jointed duringconstruction and compatible with thestrength of the masonry above.
* For CG lintels used with 140mmdense blocks please refer to“Installing a Cavity Wall Lintel’ on page 72
Cavity Wall Lintels
Standard Duty
Heavy Duty
Extra Heavy Duty
2120
CG50/100
Standard lengths (mm) 900-1500 1800 2100 2400 2700 3000-3600
SWL 1:1/3:1 (kN) 15 18 20 22 26 26
Weight (kg/m) 5.8 7.3 8.0 8.6 9.8 12.3
Nominal height ‘h’ (mm) 140 140 160 180 220 220
Standard lengths (mm) 900-1800 1950-2100 2250-2400
SWL 1:1/19:1 (kN) 32 48 45
Weight (kg/m) 10.5 13.1 13.1
Nominal height ‘h’ (mm) 157 157 157
CH50/100
CX50/100
Note: To achieve the ‘CH & CX’ loadingfigures indicated, lintels must be built-inas illustrated, ensuring that theblockwork infill is well-jointed duringconstruction and compatible with thestrength of the masonry above.
All ratios are shown inner to outer
All ratios are shown inner to outer
All ratios are shown inner to outer
Standard lengths (mm) 900-2700 2850-3000 3300-3900 4200-4800
SWL 1:1/19:1 (kN) 60 55 50 32
Weight (kg/m) 16.0 16.0 19.4 19.4
Nominal height ‘h’ (mm) 232 232 232 232
Open Back Lintels• For 50-65mm cavity • 100-115mm inner leaf
Standard lengths are available in 150mm increments up to 3000mm, 300mm at lengths3000mm - 4800mm (including 4575mm, but excluding 4500mm).
The SWL (safe working load) is based on the total UDL (uniform distributed load) overmaximum span using 150mm end bearings.
Standard lengths are available in 300mm increments.
Standard lengths are available in 150mm increments.
Standard lengths are available in 150mm increments up to 3000mm, 300mm at lengths3000mm - 4800mm (including 4575mm, but excluding 4500mm).
The SWL (safe working load) is based on the total UDL (uniform distributed load) overmaximum span using 150mm end bearings.
Standard lengths are available in 300mm increments.
Standard lengths are available in 150mm increments.
Concrete Floor LoadsWhen using the Catnic CH and CX Open Back ranges with concrete floors, always ensurethat the blockwork is built tight against the inner vertical face of the lintel, and that a mortarjoint is added to the top of the blockwork so that the floor units have an even spread overthe inner flange of the lintel. For guidance on installation refer to page 73.
Standard lengths (mm) 900-1800 1950-2100 2250-2400
SWL 1:1/19:1 (kN) 32 48 45
Weight (kg/m) 10.7 13.4 13.4
Nominal height ‘h’ (mm) 157 157 157
CH50/125
Cavity Wall Lintels
Standard Duty
Heavy Duty
Extra Heavy Duty
• For 50-65mm cavity • 125-140*mm wide inner leaf
CG50/125*
Standard lengths (mm) 900-1200 1500-1800 2100-2400 2700-3000
SWL 1:1/3:1 (kN) 12 17 20 26
Weight (kg/m) 6.3 7.8 9.0 12.9
Nominal height ‘h’ (mm) 140 140 180 220
Concrete Floor LoadsWhen using the Catnic CH and CX Open Back ranges with concrete floors, always ensurethat the blockwork is built tight against the inner vertical face of the lintel, and that a mortarjoint is added to the top of the blockwork so that the floor units have an even spread overthe inner flange of the lintel. For guidance on installation refer to page 73.
All ratios are shown inner to outer
All ratios are shown inner to outer
All ratios are shown inner to outer
Open Back Lintels
48100 95
h
125 48 95
h
125 48 95
hContinuoussolid infill
block
125 48 95
hContinuoussolid infill
block
100 48 95
hContinuoussolid infill
block
100 48 95
hContinuoussolid infill
block
CX50/125
Standard lengths (mm) 900-2700 2850-3000 3300-3900 4200-4800
SWL 1:1/19:1 (kN) 60 55 50 32
Weight (kg/m) 16.2 16.2 19.8 19.8
Nominal height ‘h’ (mm) 232 232 232 232
Where CH & CX lintels are required tosupport greater loads than the figurespublished please contact our TechnicalServices Department on 029 2033 7900.
Where CH & CX lintels are required tosupport greater loads than the figurespublished please contact our TechnicalServices Department on 029 2033 7900.
Note: To achieve the ‘CH & CX’ loadingfigures indicated, lintels must be built-inas illustrated, ensuring that theblockwork infill is well-jointed duringconstruction and compatible with thestrength of the masonry above.
2322
Cavity Wall Lintels
Standard Duty
Heavy Duty
Extra Heavy Duty
All ratios are shown inner to outer
All ratios are shown inner to outer
All ratios are shown inner to outer
Open Back Lintels• For 70-85mm cavity • 100-115mm inner leaf
Cavity Wall Lintels
Standard Duty
Heavy Duty
Extra Heavy Duty
• For 70-85mm cavity • 125-140*mm wide inner leaf
All ratios are shown inner to outer
All ratios are shown inner to outer
All ratios are shown inner to outer
Open Back Lintels
100 68 95
h
125 68 95
h
125 68 95
hContinuoussolid infill
block
125 68 95
hContinuoussolid infill
block
100 68 95
hContinuoussolid infill
block
100 68 95
h Continuoussolid infill
block
* For CG lintels used with 140mmdense blocks please refer to“Installing a Cavity Wall Lintel’ on page 72
CG70/100
Standard lengths (mm) 750-1500 1650-1800 2100 2400 2700 3000-3600
SWL 1:1/3:1 (kN) 15 18 20 22 26 26
Weight (kg/m) 6.0 7.5 8.1 8.7 10.0 12.5
Nominal height ‘h’ (mm) 140 140 160 180 220 220
Standard lengths (mm) 900-1800 1950-2100 2250-2400
SWL 1:1/19:1 (kN) 32 48 45
Weight (kg/m) 10.9 13.6 13.6
Nominal height ‘h’ (mm) 157 157 157
CH70/100
CX70/100
Note: To achieve the ‘CH & CX’ loadingfigures indicated, lintels must be built-inas illustrated, ensuring that theblockwork infill is well-jointed duringconstruction and compatible with thestrength of the masonry above.
Standard lengths (mm) 900-2700 2850-3000 3300-3900 4200-4800
SWL 1:1/19:1 (kN) 60 55 50 32
Weight (kg/m) 16.4 16.4 19.9 19.9
Nominal height ‘h’ (mm) 232 232 232 232
Standard lengths are available in 150mm increments up to 3000mm, 300mm at lengths3000mm - 4800mm (including 4575mm, but excluding 4500mm).
The SWL (safe working load) is based on the total UDL (uniform distributed load) overmaximum span using 150mm end bearings.
Standard lengths are available in 150mm increments up to 1800mm,300mm at lengths from 2100-3600mm.
Standard lengths are available in 150mm increments.
Standard lengths are available in 150mm increments up to 3000mm, 300mm at lengths3000mm - 4800mm (including 4575mm, but excluding 4500mm).
The SWL (safe working load) is based on the total UDL (uniform distributed load) overmaximum span using 150mm end bearings.
Standard lengths are available in 150mm increments up to 1800mm, 300mm at lengthsfrom 2100-3000mm.
Standard lengths are available in 150mm increments.
Concrete Floor LoadsWhen using the Catnic CH and CX Open Back ranges with concrete floors, always ensurethat the blockwork is built tight against the inner vertical face of the lintel, and that a mortarjoint is added to the top of the blockwork so that the floor units have an even spread overthe inner flange of the lintel. For guidance on installation refer to page 73.
Standard lengths (mm) 900-1800 1950-2100 2250-2400
SWL 1:1/19:1 (kN) 32 48 45
Weight (kg/m) 11.1 13.9 13.9
Nominal height ‘h’ (mm) 157 157 157
CH70/125
CG70/125*
Standard lengths (mm) 750-1200 1350-1800 2100-2400 2700-3000
SWL 1:1/3:1 (kN) 12 17 20 26
Weight (kg/m) 6.3 8.0 9.2 13.1
Nominal height ‘h’ (mm) 140 140 180 220
Concrete Floor LoadsWhen using the Catnic CH and CX Open Back ranges with concrete floors, always ensurethat the blockwork is built tight against the inner vertical face of the lintel, and that a mortarjoint is added to the top of the blockwork so that the floor units have an even spread overthe inner flange of the lintel. For guidance on installation refer to page 73.
CX70/125
Standard lengths (mm) 900-2700 2850-3000 3300-3900 4200-4800
SWL 1:1/19:1 (kN) 60 55 50 32
Weight (kg/m) 16.7 16.7 20.3 20.3
Nominal height ‘h’ (mm) 232 232 232 232
Where CH & CX lintels are required tosupport greater loads than the figurespublished please contact our TechnicalServices Department on 029 2033 7900.
Where CH & CX lintels are required tosupport greater loads than the figurespublished please contact our TechnicalServices Department on 029 2033 7900.
Note: To achieve the ‘CH & CX’ loadingfigures indicated, lintels must be built-inas illustrated, ensuring that theblockwork infill is well-jointed duringconstruction and compatible with thestrength of the masonry above.
2322
Cavity Wall Lintels
Standard Duty
Heavy Duty
Extra Heavy Duty
All ratios are shown inner to outer
All ratios are shown inner to outer
All ratios are shown inner to outer
Open Back Lintels• For 70-85mm cavity • 100-115mm inner leaf
Cavity Wall Lintels
Standard Duty
Heavy Duty
Extra Heavy Duty
• For 70-85mm cavity • 125-140*mm wide inner leaf
All ratios are shown inner to outer
All ratios are shown inner to outer
All ratios are shown inner to outer
Open Back Lintels
100 68 95
h
125 68 95
h
125 68 95
hContinuoussolid infill
block
125 68 95
hContinuoussolid infill
block
100 68 95
hContinuoussolid infill
block
100 68 95
h Continuoussolid infill
block
* For CG lintels used with 140mmdense blocks please refer to“Installing a Cavity Wall Lintel’ on page 72
CG70/100
Standard lengths (mm) 750-1500 1650-1800 2100 2400 2700 3000-3600
SWL 1:1/3:1 (kN) 15 18 20 22 26 26
Weight (kg/m) 6.0 7.5 8.1 8.7 10.0 12.5
Nominal height ‘h’ (mm) 140 140 160 180 220 220
Standard lengths (mm) 900-1800 1950-2100 2250-2400
SWL 1:1/19:1 (kN) 32 48 45
Weight (kg/m) 10.9 13.6 13.6
Nominal height ‘h’ (mm) 157 157 157
CH70/100
CX70/100
Note: To achieve the ‘CH & CX’ loadingfigures indicated, lintels must be built-inas illustrated, ensuring that theblockwork infill is well-jointed duringconstruction and compatible with thestrength of the masonry above.
Standard lengths (mm) 900-2700 2850-3000 3300-3900 4200-4800
SWL 1:1/19:1 (kN) 60 55 50 32
Weight (kg/m) 16.4 16.4 19.9 19.9
Nominal height ‘h’ (mm) 232 232 232 232
Standard lengths are available in 150mm increments up to 3000mm, 300mm at lengths3000mm - 4800mm (including 4575mm, but excluding 4500mm).
The SWL (safe working load) is based on the total UDL (uniform distributed load) overmaximum span using 150mm end bearings.
Standard lengths are available in 150mm increments up to 1800mm,300mm at lengths from 2100-3600mm.
Standard lengths are available in 150mm increments.
Standard lengths are available in 150mm increments up to 3000mm, 300mm at lengths3000mm - 4800mm (including 4575mm, but excluding 4500mm).
The SWL (safe working load) is based on the total UDL (uniform distributed load) overmaximum span using 150mm end bearings.
Standard lengths are available in 150mm increments up to 1800mm, 300mm at lengthsfrom 2100-3000mm.
Standard lengths are available in 150mm increments.
Concrete Floor LoadsWhen using the Catnic CH and CX Open Back ranges with concrete floors, always ensurethat the blockwork is built tight against the inner vertical face of the lintel, and that a mortarjoint is added to the top of the blockwork so that the floor units have an even spread overthe inner flange of the lintel. For guidance on installation refer to page 73.
Standard lengths (mm) 900-1800 1950-2100 2250-2400
SWL 1:1/19:1 (kN) 32 48 45
Weight (kg/m) 11.1 13.9 13.9
Nominal height ‘h’ (mm) 157 157 157
CH70/125
CG70/125*
Standard lengths (mm) 750-1200 1350-1800 2100-2400 2700-3000
SWL 1:1/3:1 (kN) 12 17 20 26
Weight (kg/m) 6.3 8.0 9.2 13.1
Nominal height ‘h’ (mm) 140 140 180 220
Concrete Floor LoadsWhen using the Catnic CH and CX Open Back ranges with concrete floors, always ensurethat the blockwork is built tight against the inner vertical face of the lintel, and that a mortarjoint is added to the top of the blockwork so that the floor units have an even spread overthe inner flange of the lintel. For guidance on installation refer to page 73.
CX70/125
Standard lengths (mm) 900-2700 2850-3000 3300-3900 4200-4800
SWL 1:1/19:1 (kN) 60 55 50 32
Weight (kg/m) 16.7 16.7 20.3 20.3
Nominal height ‘h’ (mm) 232 232 232 232
Where CH & CX lintels are required tosupport greater loads than the figurespublished please contact our TechnicalServices Department on 029 2033 7900.
Where CH & CX lintels are required tosupport greater loads than the figurespublished please contact our TechnicalServices Department on 029 2033 7900.
* For CG lintels used with 140mmdense blocks please refer to“Installing a Cavity Wall Lintel’ on page 72
Note: To achieve the ‘CH & CX’ loadingfigures indicated, lintels must be built-inas illustrated, ensuring that theblockwork infill is well-jointed duringconstruction and compatible with thestrength of the masonry above.
Note: To achieve the ‘CH & CX’ loadingfigures indicated, lintels must be built-inas illustrated, ensuring that theblockwork infill is well-jointed duringconstruction and compatible with thestrength of the masonry above.
2524
Cavity Wall Lintels
Standard Duty
Heavy Duty
Extra Heavy Duty
All ratios are shown inner to outer
All ratios are shown inner to outer
All ratios are shown inner to outer
Open Back Lintels• For 90-105mm cavity • 100-115mm inner leaf
Cavity Wall Lintels
Standard Duty
Heavy Duty
Extra Heavy Duty
• For 90-105mm cavity • 125-140*mm wide inner leaf
All ratios are shown inner to outer
All ratios are shown inner to outer
All ratios are shown inner to outer
Open Back Lintels
CG90/100
Standard lengths (mm) 750-1500 1650-1800 1950-2100 2250-2400 2550-2700 2850-3600
SWL 1:1/3:1 (kN) 15 18 20 22 26 26
Weight (kg/m) 6.1 7.6 8.3 8.9 10.2 13.0
Nominal height ‘h’ (mm) 140 140 160 180 220 220100 88 95
h
125 88 95
h
125 88 95
hContinuoussolid infill
block
125 88 95
h Continuoussolid infill
block
100 88 95
h Continuoussolid infill
block
100 88 95
hContinuoussolid infill
block
Standard lengths (mm) 900-1800 1950-2100 2250-2400
SWL 1:1/19:1 (kN) 32 48 45
Weight (kg/m) 11.2 14.0 14.0
Nominal height ‘h’ (mm) 157 157 157
CH90/100
CX90/100
Note: To achieve the ‘CH & CX’ loadingfigures indicated, lintels must be built-inas illustrated, ensuring that theblockwork infill is well-jointed duringconstruction and compatible with thestrength of the masonry above.
Standard lengths (mm) 900-2700 2850-3000 3300-3900 4200-4800
SWL 1:1/19:1 (kN) 60 55 50 32
Weight (kg/m) 16.9 16.9 20.5 20.5
Nominal height ‘h’ (mm) 232 232 232 232
Standard lengths are available in 150mm increments up to 3000mm, 300mm at lengths3000mm - 4800mm (including 4575mm, but excluding 4500mm).
The SWL (safe working load) is based on the total UDL (uniform distributed load) overmaximum span using 150mm end bearings.
Standard lengths are available in 150mm increments.
Standard lengths are available in 150mm increments up to 3000mm, 300mm at lengths3000mm - 4800mm (including 4575mm, but excluding 4500mm).
The SWL (safe working load) is based on the total UDL (uniform distributed load) overmaximum span using 150mm end bearings.
Standard lengths are available in 150mm increments up to 1800mm,300mm at lengths from 2100mm - 3000mm.
Standard lengths are available in 150mm increments.
Concrete Floor LoadsWhen using the Catnic CH and CX Open Back ranges with concrete floors, always ensurethat the blockwork is built tight against the inner vertical face of the lintel, and that a mortarjoint is added to the top of the blockwork so that the floor units have an even spread overthe inner flange of the lintel. For guidance on installation refer to page 73.
Standard lengths (mm) 900-1800 1950-2100 2250-2400
SWL 1:1/19:1 (kN) 32 48 45
Weight (kg/m) 11.5 14.3 14.3
Nominal height ‘h’ (mm) 157 157 157
CH90/125
CG90/125*
Standard lengths (mm) 750-1200 1350-1800 2100-2400 2700-3000
SWL 1:1/3:1 (kN) 12 17 20 26
Weight (kg/m) 6.5 8.1 9.4 13.3
Nominal height ‘h’ (mm) 140 140 180 220
Concrete Floor LoadsWhen using the Catnic CH and CX Open Back ranges with concrete floors, always ensurethat the blockwork is built tight against the inner vertical face of the lintel, and that a mortarjoint is added to the top of the blockwork so that the floor units have an even spread overthe inner flange of the lintel. For guidance on installation refer to page 73.
CX90/125
Standard lengths (mm) 900-2700 2850-3000 3300-3900 4200-4800
SWL 1:1/19:1 (kN) 60 55 50 32
Weight (kg/m) 17.2 17.2 20.9 20.9
Nominal height ‘h’ (mm) 232 232 232 232
Standard lengths are available in 150mm increments up to 3000mm, 300mm at lengthsfrom 3000-3600mm.
Where CH & CX lintels are required tosupport greater loads than the figurespublished please contact our TechnicalServices Department on 029 2033 7900.
Where CH & CX lintels are required tosupport greater loads than the figurespublished please contact our TechnicalServices Department on 029 2033 7900.
* For CG lintels used with 140mmdense blocks please refer to“Installing a Cavity Wall Lintel’ on page 72
Note: To achieve the ‘CH & CX’ loadingfigures indicated, lintels must be built-inas illustrated, ensuring that theblockwork infill is well-jointed duringconstruction and compatible with thestrength of the masonry above.
Note: To achieve the ‘CH & CX’ loadingfigures indicated, lintels must be built-inas illustrated, ensuring that theblockwork infill is well-jointed duringconstruction and compatible with thestrength of the masonry above.
2524
Cavity Wall Lintels
Standard Duty
Heavy Duty
Extra Heavy Duty
All ratios are shown inner to outer
All ratios are shown inner to outer
All ratios are shown inner to outer
Open Back Lintels• For 90-105mm cavity • 100-115mm inner leaf
Cavity Wall Lintels
Standard Duty
Heavy Duty
Extra Heavy Duty
• For 90-105mm cavity • 125-140*mm wide inner leaf
All ratios are shown inner to outer
All ratios are shown inner to outer
All ratios are shown inner to outer
Open Back Lintels
CG90/100
Standard lengths (mm) 750-1500 1650-1800 1950-2100 2250-2400 2550-2700 2850-3600
SWL 1:1/3:1 (kN) 15 18 20 22 26 26
Weight (kg/m) 6.1 7.6 8.3 8.9 10.2 13.0
Nominal height ‘h’ (mm) 140 140 160 180 220 220100 88 95
h
125 88 95
h
125 88 95
hContinuoussolid infill
block
125 88 95
h Continuoussolid infill
block
100 88 95
h Continuoussolid infill
block
100 88 95
hContinuoussolid infill
block
Standard lengths (mm) 900-1800 1950-2100 2250-2400
SWL 1:1/19:1 (kN) 32 48 45
Weight (kg/m) 11.2 14.0 14.0
Nominal height ‘h’ (mm) 157 157 157
CH90/100
CX90/100
Note: To achieve the ‘CH & CX’ loadingfigures indicated, lintels must be built-inas illustrated, ensuring that theblockwork infill is well-jointed duringconstruction and compatible with thestrength of the masonry above.
Standard lengths (mm) 900-2700 2850-3000 3300-3900 4200-4800
SWL 1:1/19:1 (kN) 60 55 50 32
Weight (kg/m) 16.9 16.9 20.5 20.5
Nominal height ‘h’ (mm) 232 232 232 232
Standard lengths are available in 150mm increments up to 3000mm, 300mm at lengths3000mm - 4800mm (including 4575mm, but excluding 4500mm).
The SWL (safe working load) is based on the total UDL (uniform distributed load) overmaximum span using 150mm end bearings.
Standard lengths are available in 150mm increments.
Standard lengths are available in 150mm increments up to 3000mm, 300mm at lengths3000mm - 4800mm (including 4575mm, but excluding 4500mm).
The SWL (safe working load) is based on the total UDL (uniform distributed load) overmaximum span using 150mm end bearings.
Standard lengths are available in 150mm increments up to 1800mm,300mm at lengths from 2100mm - 3000mm.
Standard lengths are available in 150mm increments.
Concrete Floor LoadsWhen using the Catnic CH and CX Open Back ranges with concrete floors, always ensurethat the blockwork is built tight against the inner vertical face of the lintel, and that a mortarjoint is added to the top of the blockwork so that the floor units have an even spread overthe inner flange of the lintel. For guidance on installation refer to page 73.
Standard lengths (mm) 900-1800 1950-2100 2250-2400
SWL 1:1/19:1 (kN) 32 48 45
Weight (kg/m) 11.5 14.3 14.3
Nominal height ‘h’ (mm) 157 157 157
CH90/125
CG90/125*
Standard lengths (mm) 750-1200 1350-1800 2100-2400 2700-3000
SWL 1:1/3:1 (kN) 12 17 20 26
Weight (kg/m) 6.5 8.1 9.4 13.3
Nominal height ‘h’ (mm) 140 140 180 220
Concrete Floor LoadsWhen using the Catnic CH and CX Open Back ranges with concrete floors, always ensurethat the blockwork is built tight against the inner vertical face of the lintel, and that a mortarjoint is added to the top of the blockwork so that the floor units have an even spread overthe inner flange of the lintel. For guidance on installation refer to page 73.
CX90/125
Standard lengths (mm) 900-2700 2850-3000 3300-3900 4200-4800
SWL 1:1/19:1 (kN) 60 55 50 32
Weight (kg/m) 17.2 17.2 20.9 20.9
Nominal height ‘h’ (mm) 232 232 232 232
Standard lengths are available in 150mm increments up to 3000mm, 300mm at lengthsfrom 3000-3600mm.
Where CH & CX lintels are required tosupport greater loads than the figurespublished please contact our TechnicalServices Department on 029 2033 7900.
Where CH & CX lintels are required tosupport greater loads than the figurespublished please contact our TechnicalServices Department on 029 2033 7900.
A full range of lintels is available to suit125-140mm wide inner leaf modelsplease contact our Technical ServicesDepartment on 029 2033 7900
A full range of lintels is available to suit125-140mm wide inner leaf modelsplease contact our Technical ServicesDepartment on 029 2033 7900
Note: To achieve the ‘CH & CX’ loadingfigures indicated, lintels must be built-inas illustrated, ensuring that theblockwork infill is well-jointed duringconstruction and compatible with thestrength of the masonry above.
2726
Cavity Wall Lintels
All ratios are shown inner to outer
All ratios are shown inner to outer
All ratios are shown inner to outer
Cavity Wall Lintels
• For 110-125mm cavity • 100-115mm inner leaf
• For 130-145mm cavity • 100-115mm inner leaf
Concrete Floor LoadsWhen using the Catnic CH and CX Open Back ranges with concrete floors, always ensurethat the blockwork is built tight against the inner vertical face of the lintel, and that a mortarjoint is added to the top of the blockwork so that the floor units have an even spread overthe inner flange of the lintel. For guidance on installation refer to page 73.
Open Back Lintels
100 108 95
h
100 108 95
hContinuoussolid infill
block
100 108 95
hContinuoussolid infill
block
Standard Duty
Heavy Duty
Extra Heavy Duty
All ratios are shown inner to outer
All ratios are shown inner to outer
All ratios are shown inner to outer
CG110/100
100 128 95
h
100 128 95
hContinuoussolid infill
block
100 128 95
hContinuoussolid infill
block
Standard lengths (mm) 900-1500 1800 2100 2400-3600
SWL 1:1/3:1 (kN) 15 18 20 26
Weight (kg/m) 11.3 11.3 11.9 16.8
Nominal height ‘h’ (mm) 167 167 183 247
Standard lengths are available in 150mm increments up to 3000mm,300mm at lengths from 3000mm to 3600mm
Standard lengths (mm) 900-1800 2100 2400
SWL 1:1/19:1 (kN) 32 48 45
Weight (kg/m) 12.3 14.7 14.7
Nominal height ‘h’ (mm) 157 157 157
CH110/100
CX110/100
Standard lengths (mm) 900-2700 2850-3000 3300-3900 4200-4800
SWL 1:1/19:1 (kN) 60 55 50 32
Weight (kg/m) 17.3 17.3 20.8 20.8
Nominal height ‘h’ (mm) 232 232 232 232
Standard lengths are available in 150mm increments up to 3000mm, 300mm at lengths3000mm - 4800mm (including 4575mm, but excluding 4500mm).
Standard lengths are available in 150mm increments.
Standard Duty
Heavy Duty
Extra Heavy Duty
CG130/100
Standard lengths (mm) 900-1500 1800 2100 2400-3600
SWL 1:1/3:1 (kN) 15 18 20 26
Weight (kg/m) 11.8 11.8 12.4 17.3
Nominal height ‘h’ (mm) 167 167 183 247
Standard lengths are available in 150mm increments up to 3000mm,300mm at lengths from 3000mm to 3600mm
Standard lengths (mm) 900-1800 2100 2400
SWL 1:1/19:1 (kN) 32 48 45
Weight (kg/m) 12.6 15.1 15.1
Nominal height ‘h’ (mm) 157 157 157
CH130/100
CX130/100
Standard lengths (mm) 900-2700 2850-3000 3300-3900 4200-4800
SWL 1:1/19:1 (kN) 60 55 50 32
Weight (kg/m) 17.8 17.8 21.4 21.4
Nominal height ‘h’ (mm) 232 232 232 232
Standard lengths are available in 150mm increments up to 3000mm, 300mm at lengths3000mm - 4800mm (including 4575mm, but excluding 4500mm).
Standard lengths are available in 150mm increments.
The SWL (safe working load) is based on the total UDL (uniform distributed load) overmaximum span using 150mm end bearings.
The SWL (safe working load) is based on the total UDL (uniform distributed load) overmaximum span using 150mm end bearings.
Concrete Floor LoadsWhen using the Catnic CH and CX Open Back ranges with concrete floors, always ensurethat the blockwork is built tight against the inner vertical face of the lintel, and that a mortarjoint is added to the top of the blockwork so that the floor units have an even spread overthe inner flange of the lintel. For guidance on installation refer to page 73.
Open Back Lintels
Note: To achieve the ‘CH & CX’ loadingfigures indicated, lintels must be built-inas illustrated, ensuring that theblockwork infill is well-jointed duringconstruction and compatible with thestrength of the masonry above.
Where CH & CX lintels are required tosupport greater loads than the figurespublished please contact our TechnicalServices Department on 029 2033 7900.
Where CH & CX lintels are required tosupport greater loads than the figurespublished please contact our TechnicalServices Department on 029 2033 7900.
A full range of lintels is available to suit125-140mm wide inner leaf modelsplease contact our Technical ServicesDepartment on 029 2033 7900
A full range of lintels is available to suit125-140mm wide inner leaf modelsplease contact our Technical ServicesDepartment on 029 2033 7900
Note: To achieve the ‘CH & CX’ loadingfigures indicated, lintels must be built-inas illustrated, ensuring that theblockwork infill is well-jointed duringconstruction and compatible with thestrength of the masonry above.
2726
Cavity Wall Lintels
All ratios are shown inner to outer
All ratios are shown inner to outer
All ratios are shown inner to outer
Cavity Wall Lintels
• For 110-125mm cavity • 100-115mm inner leaf
• For 130-145mm cavity • 100-115mm inner leaf
Concrete Floor LoadsWhen using the Catnic CH and CX Open Back ranges with concrete floors, always ensurethat the blockwork is built tight against the inner vertical face of the lintel, and that a mortarjoint is added to the top of the blockwork so that the floor units have an even spread overthe inner flange of the lintel. For guidance on installation refer to page 73.
Open Back Lintels
100 108 95
h
100 108 95
hContinuoussolid infill
block
100 108 95
hContinuoussolid infill
block
Standard Duty
Heavy Duty
Extra Heavy Duty
All ratios are shown inner to outer
All ratios are shown inner to outer
All ratios are shown inner to outer
CG110/100
100 128 95
h
100 128 95
hContinuoussolid infill
block
100 128 95
hContinuoussolid infill
block
Standard lengths (mm) 900-1500 1800 2100 2400-3600
SWL 1:1/3:1 (kN) 15 18 20 26
Weight (kg/m) 11.3 11.3 11.9 16.8
Nominal height ‘h’ (mm) 167 167 183 247
Standard lengths are available in 150mm increments up to 3000mm,300mm at lengths from 3000mm to 3600mm
Standard lengths (mm) 900-1800 2100 2400
SWL 1:1/19:1 (kN) 32 48 45
Weight (kg/m) 12.3 14.7 14.7
Nominal height ‘h’ (mm) 157 157 157
CH110/100
CX110/100
Standard lengths (mm) 900-2700 2850-3000 3300-3900 4200-4800
SWL 1:1/19:1 (kN) 60 55 50 32
Weight (kg/m) 17.3 17.3 20.8 20.8
Nominal height ‘h’ (mm) 232 232 232 232
Standard lengths are available in 150mm increments up to 3000mm, 300mm at lengths3000mm - 4800mm (including 4575mm, but excluding 4500mm).
Standard lengths are available in 150mm increments.
Standard Duty
Heavy Duty
Extra Heavy Duty
CG130/100
Standard lengths (mm) 900-1500 1800 2100 2400-3600
SWL 1:1/3:1 (kN) 15 18 20 26
Weight (kg/m) 11.8 11.8 12.4 17.3
Nominal height ‘h’ (mm) 167 167 183 247
Standard lengths are available in 150mm increments up to 3000mm,300mm at lengths from 3000mm to 3600mm
Standard lengths (mm) 900-1800 2100 2400
SWL 1:1/19:1 (kN) 32 48 45
Weight (kg/m) 12.6 15.1 15.1
Nominal height ‘h’ (mm) 157 157 157
CH130/100
CX130/100
Standard lengths (mm) 900-2700 2850-3000 3300-3900 4200-4800
SWL 1:1/19:1 (kN) 60 55 50 32
Weight (kg/m) 17.8 17.8 21.4 21.4
Nominal height ‘h’ (mm) 232 232 232 232
Standard lengths are available in 150mm increments up to 3000mm, 300mm at lengths3000mm - 4800mm (including 4575mm, but excluding 4500mm).
Standard lengths are available in 150mm increments.
The SWL (safe working load) is based on the total UDL (uniform distributed load) overmaximum span using 150mm end bearings.
The SWL (safe working load) is based on the total UDL (uniform distributed load) overmaximum span using 150mm end bearings.
Concrete Floor LoadsWhen using the Catnic CH and CX Open Back ranges with concrete floors, always ensurethat the blockwork is built tight against the inner vertical face of the lintel, and that a mortarjoint is added to the top of the blockwork so that the floor units have an even spread overthe inner flange of the lintel. For guidance on installation refer to page 73.
Open Back Lintels
Note: To achieve the ‘CH & CX’ loadingfigures indicated, lintels must be built-inas illustrated, ensuring that theblockwork infill is well-jointed duringconstruction and compatible with thestrength of the masonry above.
Where CH & CX lintels are required tosupport greater loads than the figurespublished please contact our TechnicalServices Department on 029 2033 7900.
Where CH & CX lintels are required tosupport greater loads than the figurespublished please contact our TechnicalServices Department on 029 2033 7900.
2928
Cavity Wall Lintels Cavity Wall Lintels
All ratios are shown inner to outer
Note: To achieve the ‘CH & CX’ loadingfigures indicated, lintels must be built-inas illustrated, ensuring that theblockwork infill is well-jointed duringconstruction and compatible with thestrength of the masonry above.
All ratios are shown inner to outer
All ratios are shown inner to outer
• For 150-165mm cavity • 100-115mm inner leaf
100 148 95
h
100 148 95
hContinuoussolid infill
block
100 148 95
hContinuoussolid infill
block
All ratios are shown inner to outer
All ratios are shown inner to outer
All ratios are shown inner to outer
100 50 130
100 70 130
100 90 140
Standard Duty
Heavy Duty
Extra Heavy Duty
CG150/100
Standard lengths (mm) 900-1500 1800 2100 2400-3600
SWL 1:1/3:1 (kN) 15 18 20 26
Weight (kg/m) 12.3 12.3 12.9 17.7
Nominal height ‘h’ (mm) 167 167 183 247
Standard lengths are available in 150mm increments up to 3000mm,300mm at lengths from 3000mm to 3600mm
Standard lengths (mm) 900-1800 2100 2400
SWL 1:1/19:1 (kN) 32 48 45
Weight (kg/m) 13.1 15.6 15.6
Nominal height ‘h’ (mm) 157 157 157
CH150/100
CX150/100
Standard lengths (mm) 900-2700 2850-3000 3300-3900 4200-4800
SWL 1:1/19:1 (kN) 60 55 50 32
Weight (kg/m) 18.2 18.2 21.9 21.9
Nominal height ‘h’ (mm) 232 232 232 232
Standard lengths are available in 150mm increments up to 3000mm, 300mm at lengths3000mm - 4800mm (including 4575mm, but excluding 4500mm).
Standard lengths are available in 150mm increments.
The SWL (safe working load) is based on the total UDL (uniform distributed load) overmaximum span using 150mm end bearings.
The SWL (safe working load) is based on the total UDL (uniform distributed load) overmaximum span using 150mm end bearings.
Concrete Floor LoadsWhen using the Catnic CH and CX Open Back ranges with concrete floors, always ensurethat the blockwork is built tight against the inner vertical face of the lintel, and that a mortarjoint is added to the top of the blockwork so that the floor units have an even spread overthe inner flange of the lintel. For guidance on installation refer to page 73.
Open Back Lintels
Standard Duty - 50mm Cavity
Standard Duty - 75mm Cavity
Standard Duty - 100mm CavityCN99/1644C
Wider Outer Leaf Lintels• For 140-150mm wide outer leaf• 50-100mm cavity • 100-115mm inner leaf
CN42C
CN99/124C
Standard lengths (mm) 750-4200
SWL 1:1/5:1 (kN) 29
Weight (kg/m) 20.5
Nominal height ‘h’ (mm) 219
Standard lengths (mm) 750-4200
SWL 1:1/5:1 (kN) 29
Weight (kg/m) 20.6
Nominal height ‘h’ (mm) 219
Standard lengths (mm) 750-4200
SWL 1:1/5:1 (kN) 29
Weight (kg/m) 21.4
Nominal height ‘h’ (mm) 219
Standard lengths are available in 150mm increments up to 3000mm,300mm at lengths 3000mm - 4200mm.
Standard lengths are available in 150mm increments up to 3000mm,300mm at lengths 3000mm - 4200mm.
Standard lengths are available in 150mm increments up to 3000mm,300mm at lengths 3000mm - 4200mm.
Where CH & CX lintels are required tosupport greater loads than the figurespublished please contact our TechnicalServices Department on 029 2033 7900.
A full range of lintels is available to suit125-140mm wide inner leaf modelsplease contact our Technical ServicesDepartment on 029 2033 7900
2928
Cavity Wall Lintels Cavity Wall Lintels
All ratios are shown inner to outer
Note: To achieve the ‘CH & CX’ loadingfigures indicated, lintels must be built-inas illustrated, ensuring that theblockwork infill is well-jointed duringconstruction and compatible with thestrength of the masonry above.
All ratios are shown inner to outer
All ratios are shown inner to outer
• For 150-165mm cavity • 100-115mm inner leaf
100 148 95
h
100 148 95
hContinuoussolid infill
block
100 148 95
hContinuoussolid infill
block
All ratios are shown inner to outer
All ratios are shown inner to outer
All ratios are shown inner to outer
100 50 130
100 70 130
100 90 140
Standard Duty
Heavy Duty
Extra Heavy Duty
CG150/100
Standard lengths (mm) 900-1500 1800 2100 2400-3600
SWL 1:1/3:1 (kN) 15 18 20 26
Weight (kg/m) 12.3 12.3 12.9 17.7
Nominal height ‘h’ (mm) 167 167 183 247
Standard lengths are available in 150mm increments up to 3000mm,300mm at lengths from 3000mm to 3600mm
Standard lengths (mm) 900-1800 2100 2400
SWL 1:1/19:1 (kN) 32 48 45
Weight (kg/m) 13.1 15.6 15.6
Nominal height ‘h’ (mm) 157 157 157
CH150/100
CX150/100
Standard lengths (mm) 900-2700 2850-3000 3300-3900 4200-4800
SWL 1:1/19:1 (kN) 60 55 50 32
Weight (kg/m) 18.2 18.2 21.9 21.9
Nominal height ‘h’ (mm) 232 232 232 232
Standard lengths are available in 150mm increments up to 3000mm, 300mm at lengths3000mm - 4800mm (including 4575mm, but excluding 4500mm).
Standard lengths are available in 150mm increments.
The SWL (safe working load) is based on the total UDL (uniform distributed load) overmaximum span using 150mm end bearings.
The SWL (safe working load) is based on the total UDL (uniform distributed load) overmaximum span using 150mm end bearings.
Concrete Floor LoadsWhen using the Catnic CH and CX Open Back ranges with concrete floors, always ensurethat the blockwork is built tight against the inner vertical face of the lintel, and that a mortarjoint is added to the top of the blockwork so that the floor units have an even spread overthe inner flange of the lintel. For guidance on installation refer to page 73.
Open Back Lintels
Standard Duty - 50mm Cavity
Standard Duty - 75mm Cavity
Standard Duty - 100mm CavityCN99/1644C
Wider Outer Leaf Lintels• For 140-150mm wide outer leaf• 50-100mm cavity • 100-115mm inner leaf
CN42C
CN99/124C
Standard lengths (mm) 750-4200
SWL 1:1/5:1 (kN) 29
Weight (kg/m) 20.5
Nominal height ‘h’ (mm) 219
Standard lengths (mm) 750-4200
SWL 1:1/5:1 (kN) 29
Weight (kg/m) 20.6
Nominal height ‘h’ (mm) 219
Standard lengths (mm) 750-4200
SWL 1:1/5:1 (kN) 29
Weight (kg/m) 21.4
Nominal height ‘h’ (mm) 219
Standard lengths are available in 150mm increments up to 3000mm,300mm at lengths 3000mm - 4200mm.
Standard lengths are available in 150mm increments up to 3000mm,300mm at lengths 3000mm - 4200mm.
Standard lengths are available in 150mm increments up to 3000mm,300mm at lengths 3000mm - 4200mm.
Where CH & CX lintels are required tosupport greater loads than the figurespublished please contact our TechnicalServices Department on 029 2033 7900.
A full range of lintels is available to suit125-140mm wide inner leaf modelsplease contact our Technical ServicesDepartment on 029 2033 7900
Material usedSupplied in post galvanised finish.Lintels manufactured from a universalbeam section and 6.0mm structuralgrade steel plate Grade S275 to BSEN 10025:2004 and hot dipgalvanised after manufacture to BSEN ISO1461:1999.
Standard increment lengthsOverall lengths are available in 50mmincrements for lengths up to 6600mm.
Optional ExtraAs an optional extra, CXL lintels canbe supplied with expanded metalmesh secured to the base plate.
Load ratiosTo achieve the loading figuresshown, the lintel must be laterallyrestrained and have 200mm endbearing supports and inner to outerload ratios between 5:1 and 19:1.
Separate DPCA separate flexible DPC must beinstalled during construction.
6
6
213
133
265
259
3130
Application:
50mm cavity & 110-115mm inner leaf
Application:
70mm cavity & 100-115mm inner leaf
The SWL (safe working load) is based on the total UDL (uniform
distributed load) over maximum span using 200mm end bearings.
CXL240
Standard lengths (mm) 2100-3000 3300-4800 5100 5400 5700 6000 6300 6600SWL 5:1/19:1(kN) 88 83 78 71 64 56 52 47Weight (kg/m) 41.1 41.1 41.1 41.1 41.1 41.1 41.1 41.1Ixx (cm4) 4051 4051 4051 4051 4051 4051 4051 4051Zxx (cm3) 303 303 303 303 303 303 303 303Serviceability moment (kNm) 50 50 50 50 50 50 50 50Allowable reaction (kN) 66 66 66 66 66 66 66 66
CXL265
Standard lengths (mm) 2100-3000 3300-4800 5100 5400 5700 6000 6300 6600SWL 5:1/19:1 (kN) 88 83 78 71 64 56 52 47Weight (kg/m) 42.3 42.3 42.3 42.3 42.3 42.3 42.3 42.3Ixx (cm4) 4139 4139 4139 4139 4139 4139 4139 4139Zxx (cm3) 305 305 305 305 305 305 305 305Serviceability moment (kNm) 50.3 50.3 50.3 50.3 50.3 50.3 50.3 50.3Allowable reaction (kN) 66 66 66 66 66 66 66 66
240
236
6
6
213
133
Standard lengths are available in 50mm increments for lengths up to 6600mm.
Standard lengths are available in 50mm increments for lengths up to 6600mm.
Lintels for extreme loadsLonger spansHigh loads at longer spans
Varying widthsSuits a variety of wall widths – with special widths on application
Note:
For alternative cavity wall constructions please contact
our Technical Services Department on 029 2033 7900.
Extreme Load Lintels
For longer lengths to supportheavy loads, please refer toour Technical ServicesDepartment on 029 2033 7900.
Cavity Wall ‘CXL’ Fabricated LintelsDesigned for external cavity wallswhen extreme loads are imposed
6
6
213
133
265
259
Application:
70mm cavity & 100-115mm inner leafCXL265
Standard lengths (mm) 2100-3000 3300-4800 5100 5400 5700 6000 6300 6600SWL 5:1/19:1 (kN) 88 83 78 71 64 56 52 47Weight (kg/m) 42.3 42.3 42.3 42.3 42.3 42.3 42.3 42.3Ixx (cm4) 4139 4139 4139 4139 4139 4139 4139 4139Zxx (cm3) 305 305 305 305 305 305 305 305Serviceability moment (kNm) 50.3 50.3 50.3 50.3 50.3 50.3 50.3 50.3Allowable reaction (kN) 66 66 66 66 66 66 66 66
Standard lengths are available in 50mm increments for lengths up to 6600mm.
Application:
50mm cavity & 110-115mm inner leafCXL240
Standard lengths (mm) 2100-3000 3300-4800 5100 5400 5700 6000 6300 6600SWL 5:1/19:1(kN) 88 83 78 71 64 56 52 47Weight (kg/m) 41.1 41.1 41.1 41.1 41.1 41.1 41.1 41.1Ixx (cm4) 4051 4051 4051 4051 4051 4051 4051 4051Zxx (cm3) 303 303 303 303 303 303 303 303Serviceability moment (kNm) 50.0 50.0 50.0 50.0 50.0 50.0 50.0 50.0Allowable reaction (kN) 66 66 66 66 66 66 66 66 240
236
6
6
213
133
Standard lengths are available in 50mm increments for lengths up to 6600mm.
31
The SWL (safe working load) is based on the total UDL (uniform
distributed load) over maximum span using 200mm end bearings.
For alternative cavity wallconstructions, please contactour Technical ServicesDepartment on 029 2033 7900.
CXL290
Standard lengths (mm) 2100-3000 3300-4800 5100 5400 5700 6000 6300 6600SWL 5:1/19:1 (kN) 88 83 78 71 64 56 52 47Weight (kg/m) 43.5 43.5 43.5 43.5 43.5 43.5 43.5 43.5Ixx (cm4) 4222 4222 4222 4222 4222 4222 4222 4222Zxx (cm3) 307 307 307 307 307 307 307 307Serviceability moment (kNm) 50.6 50.6 50.6 50.6 50.6 50.6 50.6 50.6Allowable reaction (kN) 66 66 66 66 66 66 66 66
6
6
213
133
290
284
Application:
90mm cavity & 100-115mm inner leaf
Standard lengths are available in 50mm increments for lengths up to 6600mm.
08 Catnic Brochure JAN 09:Layout 1 02/02/2009 17:17 Page 31
32
Extreme Load Lintels
Cavity Wall ‘CXL’ Fabricated Lintels
Application:
130mm cavity & 100-115mm inner leafCXL330
Standard lengths (mm) 2100-3000 3300-4800 5100 5400 5700 6000 6300 6600SWL 5:1/19:1 (kN) 88 83 78 71 64 56 52 47Weight (kg/m) 45.3 45.3 45.3 45.3 45.3 45.3 45.3 45.3Ixx (cm4) 4346 4346 4346 4346 4346 4346 4346 4346Zxx (cm3) 311 311 311 311 311 311 311 311Serviceability moment (kNm) 51.0 51.0 51.0 51.0 51.0 51.0 51.0 51.0Allowable reaction (kN) 66 66 66 66 66 66 66 66
Standard lengths are available in 50mm increments for lengths up to 6600mm.
Application:
110mm cavity & 110-115mm inner leafCXL310
Standard lengths (mm) 2100-3000 3300-4800 5100 5400 5700 6000 6300 6600SWL 5:1/19:1(kN) 88 83 78 71 64 56 52 47Weight (kg/m) 44.3 44.3 44.3 44.3 44.3 44.3 44.3 44.3Ixx (cm4) 4285 4285 4285 4285 4285 4285 4285 4285Zxx (cm3) 310 310 310 310 310 310 310 310Serviceability moment (kNm) 50.8 50.8 50.8 50.8 50.8 50.8 50.8 50.8Allowable reaction (kN) 66 66 66 66 66 66 66 66
6
6
213
133
310
304
6
6
213
133
330
324
6
6
213
133
350
344
Standard lengths are available in 50mm increments for lengths up to 6600mm.
CXL350
Standard lengths (mm) 2100-3000 3300-4800 5100 5400 5700 6000 6300 6600SWL 5:1/19:1 (kN) 88 83 78 71 64 56 52 47Weight (kg/m) 46.2 46.2 46.2 46.2 46.2 46.2 46.2 46.2Ixx (cm4) 4404 4404 4404 4404 4404 4404 4404 4404Zxx (cm3) 312 312 312 312 312 312 312 312Serviceability moment (kNm) 51.1 51.1 51.1 51.1 51.1 51.1 51.1 51.1Allowable reaction (kN) 66 66 66 66 66 66 66 66
Application:
150mm cavity & 110-115mm inner leaf
Standard lengths are available in 50mm increments for lengths up to 6600mm.
The SWL (safe working load) is based on the total UDL (uniform
distributed load) over maximum span using 200mm end bearings.
For alternative cavity wallconstructions, please contactour Technical ServicesDepartment on 029 2033 7900.
08 Catnic Brochure JAN 09:Layout 1 02/02/2009 17:17 Page 32
32 33
Cavity Wall Eaves LintelsClosed Eaves Lintels
Eaves LintelsClosed eaves lintels aremanufactured from galvanisedsteel and powder coated forextra protection. Available inboth Cougar open back orClassic box styles
Cougar Open Back Classic Box
For use in cavity wall constructionfor closed eaves applications
Easy-to-use open back profileOpen back style lintels allow masonry to be built upcontinuously on inner leaf
Duplex Corrosion Protection SystemEnsures optimum durability and longevity
Continuous insulationMaximising thermal efficiency, minimising cold bridging
Integral plaster keyWith staggered slots to the inner flange and ribbedunderside of insulation
Typical applications• Universal application caters for all loading conditions• Direct roof loading• Attic truss loads• Supports point loads eg. multiple trusses
Duplex Corrosion Protection SystemEnsures optimum durability and longevity
Continuous insulationMaximising thermal efficiency, minimising cold bridging
Integral plaster keyWith staggered slots to the underside of box section
Eaves Lintel
To achieve the stated safe working load (SWL), closed eaves lintels must be built in with solid blockwork and continuous timberwall-plates. Allow 150mm at each end for bearing support.
Application:
140mm cavity & 100-115mm inner leaf
CXL315
Standard lengths (mm) 2100-3000 3300-4800 5100 5400 5700 6000 6300 6600SWL 5:1/19:1(kN) 88 83 78 71 64 56 52 47Weight (kg/m) 44.6 44.6 44.6 44.6 44.6 44.6 44.6 44.6Ixx (cm4) 4301 4301 4301 4301 4301 4301 4301 4301Zxx (cm3) 311 311 311 311 311 311 311 311Serviceability moment (kNm) 50.9 50.9 50.9 50.9 50.9 50.9 50.9 50.9Allowable reaction (kN) 66 66 66 66 66 66 66 66
CXL340
Standard lengths (mm) 2100-3000 3300-4800 5100 5400 5700 6000 6300 6600SWL 5:1/19:1 (kN) 88 83 78 71 64 56 52 47Weight (kg/m) 45.8 45.8 45.8 45.8 45.8 45.8 45.8 45.8Ixx (cm4) 4375 4375 4375 4375 4375 4375 4375 4375Zxx (cm3) 312 312 312 312 312 312 312 312Serviceability moment (kNm) 51.6 51.6 51.6 51.6 51.6 51.6 51.6 51.6Allowable reaction (kN) 66 66 66 66 66 66 66 66
6
6
213
133
315
309
6
6
213
133
340
334
Application:
115mm cavity & 100-115mm inner leaf
Standard lengths are available in 50mm increments for lengths up to 6600mm.
Standard lengths are available in 50mm increments for lengths up to 6600mm.
The SWL (safe working load) is based on the total UDL (uniform
distributed load) over maximum span using 200mm end bearings.
Extreme Load Lintels
CXL290
Standard lengths (mm) 2100-3000 3300-4800 5100 5400 5700 6000 6300 6600SWL 5:1/19:1 (kN) 88 83 78 71 64 56 52 47Weight (kg/m) 43.5 43.5 43.5 43.5 43.5 43.5 43.5 43.5Ixx (cm4) 4222 4222 4222 4222 4222 4222 4222 4222Zxx (cm3) 307 307 307 307 307 307 307 307Serviceability moment (kNm) 50.6 50.6 50.6 50.6 50.6 50.6 50.6 50.6Allowable reaction (kN) 66 66 66 66 66 66 66 66
6
6
213
133
290
284
Application:
90mm cavity & 100-115mm inner leaf
Standard lengths are available in 50mm increments for lengths up to 6600mm.
Cavity Wall ‘CXL’ Fabricated Lintels
35
Timber Frame Lintels
Note: lintels should be suitably propped during
construction. Refer to “Installing Timber Frame Lintel
on page 74.
CTF5 Lintel
CN23 Lintel
34
Closed Eaves Lintels
BenefitsDuplex corrosion protection
Ensures optimum durability andlongevity.
Built-in Damp Proof CourseSloping outer face and Duplexcorrosion protection together providea built-in DPC.
Restraint clipsAllows vertical differential movementof timber frame.
All timber frame models must besecured with restraint clips (supplied)and a batten (not supplied) to preventlateral deflection (twist) during thebuilding stage and to achieve theloading figures shown.
For use in timberframe construction
Timber Frame Lintels
Timber FrameThe timber frame rangeconsists of single and double elements lintels with a sloping outer face and Duplex corrosionprotection which togetherprovide a built in DPC
100 48 60
h
100 88 60
h
Standard lengths are available in 300mm increments.
• For 50-85mm cavity• 100-115mm inner leafCGE50/100
Standard lengths (mm) 900-1500 1800-2100 2400 2700SWL (kN)* 25 22 20 20Weight (kg/m) 7.0 8.0 10.2 10.2Nominal height ‘h’ (mm) 95 115 115 115
Standard lengths are available in 300mm increments.
• For 90-105mm cavity• 100-115mm inner leafCGE90/100
Standard lengths (mm) 900-1500 1800-2100 2400 2700SWL (kN)* 25 22 20 20Weight (kg/m) 7.7 8.3 10.7 10.7Nominal height ‘h’ (mm) 95 115 115 115
Standard lengths are available in increments of 150mm. For lengths over 2700mm please contact Technical Services.
Standard lengths are available in increments of 150mm. For lengths over 2700mm please contact Technical Services.
• For 50-75mm cavity• 100mm inner leafCN55A
Standard lengths (mm) 900&1200 1500 1650-2100 2400&2700SWL (kN) 30 30 25 20Weight (kg/m) 9.0 9.0 9.0 9.0
CN55C
Standard lengths (mm) 900&1200 1500 1650-2100 2400&2700SWL (kN) 50 50 40 30Weight (kg/m) 12.8 12.8 12.8 12.8
100 75
143
Open Back
Note: for lintels to suit 100mm cavitiesrefer to CN71 or CN81 on Page 38.
35
Timber Frame Lintels
Note: lintels should be suitably propped during
construction. Refer to “Installing Timber Frame Lintel
on page 74.
CTF5 Lintel
CN23 Lintel
34
Closed Eaves Lintels
BenefitsDuplex corrosion protection
Ensures optimum durability andlongevity.
Built-in Damp Proof CourseSloping outer face and Duplexcorrosion protection together providea built-in DPC.
Restraint clipsAllows vertical differential movementof timber frame.
All timber frame models must besecured with restraint clips (supplied)and a batten (not supplied) to preventlateral deflection (twist) during thebuilding stage and to achieve theloading figures shown.
For use in timberframe construction
Timber Frame Lintels
Timber FrameThe timber frame rangeconsists of single and double elements lintels with a sloping outer face and Duplex corrosionprotection which togetherprovide a built in DPC
100 48 60
h
100 88 60
h
Standard lengths are available in 300mm increments.
• For 50-85mm cavity• 100-115mm inner leafCGE50/100
Standard lengths (mm) 900-1500 1800-2100 2400 2700SWL (kN)* 25 22 20 20Weight (kg/m) 7.0 8.0 10.2 10.2Nominal height ‘h’ (mm) 95 115 115 115
Standard lengths are available in 300mm increments.
• For 90-105mm cavity• 100-115mm inner leafCGE90/100
Standard lengths (mm) 900-1500 1800-2100 2400 2700SWL (kN)* 25 22 20 20Weight (kg/m) 7.7 8.3 10.7 10.7Nominal height ‘h’ (mm) 95 115 115 115
Standard lengths are available in increments of 150mm. For lengths over 2700mm please contact Technical Services.
Standard lengths are available in increments of 150mm. For lengths over 2700mm please contact Technical Services.
• For 50-75mm cavity• 100mm inner leafCN55A
Standard lengths (mm) 900&1200 1500 1650-2100 2400&2700SWL (kN) 30 30 25 20Weight (kg/m) 9.0 9.0 9.0 9.0
CN55C
Standard lengths (mm) 900&1200 1500 1650-2100 2400&2700SWL (kN) 50 50 40 30Weight (kg/m) 12.8 12.8 12.8 12.8
100 75
143
Open Back
Note: for lintels to suit 100mm cavitiesrefer to CN71 or CN81 on Page 38.
38 95
h
37
External Solid Wall Lintels
For use in 200mm & 215mm solid exterior walls
Benefits• Box Profile
Saves on brickwork and insulation.Resists twisting during construction
• Instant full load useBox profile is designed to carry full load of wet masonry as soonas it is installed
Duplex Corrosion Protection SystemEnsures optimum durability and longevity
Continuous insulationMaximising thermal efficiency, minimising cold bridging
Integral plaster keyWith staggered slots to side and underside of the boxprofile
Designed to carry two separate leaves of215mm fairface brick wall
Duplex Corrosion Protection SystemEnsures optimum durability and longevity
External Solid Wall CN71 Lintel
36
The SWL (safe working load) is based on the total UDL (uniform distributed load) over maximum span using 150mm end bearings.
CTF5
• For 70-80mm cavity & 102mm outer leafStandard DutyCTF7
Standard lengths (mm) 750-1200 1350-1500 1650-2400 2550-3000 3300-3600 3900-4800SWL (kN) 4 5 7 7 9 10Weight (kg/m) 4.2 5.2 5.9 7.5 8.3 9.3Nominal height ‘h’ (mm) 145 145 187 187 218 265
• For 90-100mm cavity & 102mm outer leafStandard DutyCTF9
Standard lengths (mm) 750-1500 1650-2400 2550-3000 3300-3600 3900-4800SWL (kN) 5 7 7 9 10Weight (kg/m) 4.7 5.9 8.1 8.4 9.6Nominal height ‘h’ (mm) 146 146 200 220 271
• For 35-60mm cavity & 102mm outer leafHeavy DutyCN23B CN23C
Standard lengths (mm) 750-3600SWL (kN) 10Weight (kg/m) 12.8Nominal height ‘h’ (mm) 268
3900-480010
16.3268
For use in solid or block walls200mm to 215mm
Solid WallsExternal solid wall lintels aremanufactured from galvanisedsteel and powder coated forextra protection. Available inClassic box or two-pieceinverted ‘T’ styles
Classic Box Two-piece inverted ‘T’
CN51 Lintel
Timber Frame Lintels
External Solid Walls
47 95
h
67 95
h
• For 50-60mm cavity & 102mm outer leafStandard Duty
Standard lengths (mm) 750-1200 1350-1500 1650-2400 2550-3000 3300-3600 3900-4800SWL (kN) 4 5 7 7 9 10Weight (kg/m) 3.8 4.8 5.6 7.2 8.0 9.0Nominal height ‘h’ (mm) 128 128 183 183 218 256
h
90 95
Standard lengths are available in 150mm increments up to 3000mm, 300mm at lengths from 3000mm - 4800mm.
Standard lengths are available in 150mm increments up to 3000mm, 300mm at lengths from 3000mm - 4800mm.
Standard lengths are available in 150mm increments up to 3000mm, 300mm at lengths from 3000mm - 4800mm.
Standard lengths are available in 150mm increments up to 3000mm, 300mm at lengths from 3000mm - 4800mm (including 4575mm but excluding 4500mm).
38 95
h
37
External Solid Wall Lintels
For use in 200mm & 215mm solid exterior walls
Benefits• Box Profile
Saves on brickwork and insulation.Resists twisting during construction
• Instant full load useBox profile is designed to carry full load of wet masonry as soonas it is installed
Duplex Corrosion Protection SystemEnsures optimum durability and longevity
Continuous insulationMaximising thermal efficiency, minimising cold bridging
Integral plaster keyWith staggered slots to side and underside of the boxprofile
Designed to carry two separate leaves of215mm fairface brick wall
Duplex Corrosion Protection SystemEnsures optimum durability and longevity
External Solid Wall CN71 Lintel
36
The SWL (safe working load) is based on the total UDL (uniform distributed load) over maximum span using 150mm end bearings.
CTF5
• For 70-80mm cavity & 102mm outer leafStandard DutyCTF7
Standard lengths (mm) 750-1200 1350-1500 1650-2400 2550-3000 3300-3600 3900-4800SWL (kN) 4 5 7 7 9 10Weight (kg/m) 4.2 5.2 5.9 7.5 8.3 9.3Nominal height ‘h’ (mm) 145 145 187 187 218 265
• For 90-100mm cavity & 102mm outer leafStandard DutyCTF9
Standard lengths (mm) 750-1500 1650-2400 2550-3000 3300-3600 3900-4800SWL (kN) 5 7 7 9 10Weight (kg/m) 4.7 5.9 8.1 8.4 9.6Nominal height ‘h’ (mm) 146 146 200 220 271
• For 35-60mm cavity & 102mm outer leafHeavy DutyCN23B CN23C
Standard lengths (mm) 750-3600SWL (kN) 10Weight (kg/m) 12.8Nominal height ‘h’ (mm) 268
3900-480010
16.3268
For use in solid or block walls200mm to 215mm
Solid WallsExternal solid wall lintels aremanufactured from galvanisedsteel and powder coated forextra protection. Available inClassic box or two-pieceinverted ‘T’ styles
Classic Box Two-piece inverted ‘T’
CN51 Lintel
Timber Frame Lintels
External Solid Walls
47 95
h
67 95
h
• For 50-60mm cavity & 102mm outer leafStandard Duty
Standard lengths (mm) 750-1200 1350-1500 1650-2400 2550-3000 3300-3600 3900-4800SWL (kN) 4 5 7 7 9 10Weight (kg/m) 3.8 4.8 5.6 7.2 8.0 9.0Nominal height ‘h’ (mm) 128 128 183 183 218 256
h
90 95
Standard lengths are available in 150mm increments up to 3000mm, 300mm at lengths from 3000mm - 4800mm.
Standard lengths are available in 150mm increments up to 3000mm, 300mm at lengths from 3000mm - 4800mm.
Standard lengths are available in 150mm increments up to 3000mm, 300mm at lengths from 3000mm - 4800mm.
Standard lengths are available in 150mm increments up to 3000mm, 300mm at lengths from 3000mm - 4800mm (including 4575mm but excluding 4500mm).
Standard lengths (mm) 750-1800 1950-2700SWL (kN) 10 12Weight (kg/m) 9.0 12.7Nominal height ‘h’ (mm) 91 167
• For 200mm & 215mm Exterior Solid Walls
CN71A CN71C
Standard lengths (mm) 750-1500 1650-2100 2250-2700 900-1500 1650-1950SWL (kN) 29 27 20 49 44Weight (kg/m) 9.3 9.3 9.3 14.6 14.6Nominal height ‘h’ (mm) 143 143 143 143 143
38
Standard lengths are available in increments of 300mm
(including 4575mm, but excluding 4500mm).
External Solid Wall Lintels
CN50C CN51C
• For two separate leaves of a 215mm fairface brick wall
Classic Box & Two-piece ‘T’ Profile
100 95
143
h
100 95
182
h
CN81CCN81B
Standard lengths (mm) 2100-3600 2100-2700 2850-3300 3600 3900-4575 4800SWL (kN) 29 54 47 39 29 26Weight (kg/m) 15.1 18.5 18.5 18.5 18.5 18.5Nominal height ‘h’ (mm) 219 219 219 219 219 219
Standard lengths are available in increments of 150mm.
Standard lengths are available in increments of 150mm at lengths up to 3000mm,
300mm at lengths from 3000mm – 4800mm (including 4575mm, but excluding 4500mm).
Standard Duty
Standard Duty Heavy Duty
Standard Duty Standard Duty
Heavy Duty
CN99/394C
Standard lengths (mm) 3000-3300 3600-3900 4200-4800SWL (kN) 54 51 49Weight (kg/m) 22.3 22.3 22.3Nominal height ‘h’ (mm) 295 295 295
Heavy Duty
Standard lengths are availble in increments of 150mm.
The SWL (safe working load) is based on the total UDL (uniform
distributed load) over maximum span using 150mm end bearings.
08 Catnic Brochure JAN 09:Layout 1 04/02/2009 10:12 Page 38
The SWL (safe working load) is based on the total UDL (uniform
distributed load) over maximum span using 150mm end bearings.
CN81 Lintel
CG Lintel installedin solid wallconstruction
For solid wall construction in excess of 250mman appropriate Cougar Open Back Lintel can beutilised.
Box lintel profiles can be used in Tile HangingApplications on External Solid Walls.
• For 200mm & 215mm Exterior Solid Walls
CN71A CN71C
Standard lengths (mm) 750-1500 1650-2100 2250-2700 900-1500 1650-1950SWL (kN) 29 27 20 49 44Weight (kg/m) 9.3 9.3 9.3 14.6 14.6Nominal height ‘h’ (mm) 143 143 143 143 143
3938
External Solid Wall Lintels
Standard lengths are availble in increments of 150mm.
External Solid Wall Lintels
CN50C CN51C
Standard lengths (mm) 750-1800 1950-2700SWL (kN) 10 12Weight (kg/m) 9.0 12.7Nominal height ‘h’ (mm) 91 167
• For two separate leaves of a 215mm fairface brick wall
Classic Box & Two-piece ‘T’ Profile
100 95
143
219
100 95
182
h
CN81CCN81B
Standard lengths (mm) 2100-3600 2100-2700 2850-3300 3600 3900-4575 4800SWL (kN) 29 54 47 39 29 26Weight (kg/m) 15.1 18.5 18.5 18.5 18.5 18.5Nominal height ‘h’ (mm) 219 219 219 219 219 219
Other typical External Solid Wall Lintel Applications
Standard lengths are available in increments of 150mm.
Standard lengths are available in increments of 150mm at lengths up to 3000mm,
300mm at lengths from 3000mm – 4800mm (including 4575mm, but excluding 4500mm).
Standard Duty
Standard Duty Heavy Duty
Standard Duty Standard Duty
Heavy Duty
100
55
h
95
70
h
4140
For use in 102mm exterior walls
ApplicationsCNZ94A suitable for use over meter boxes only.CNZ94C, CNZ95C, CNZ96C & CNZ97C suitable for light duty loading applications
For use in 102mm exterior walls
ApplicationsCN48C & CN49C lintels are fully built into wall construction foruse with single leaf face brick or block walls
Duplex Corrosion Protection SystemEnsures optimum durability and longevity
For use in solid or block walls
Catnic single leaf lintels are available in an angle and ‘C’ shaped profile toaccommodate meter boxesand single leaf face brick or block walls
Angle ‘C’ Profile
External Solid Walls
Lintels CN48 and CN49 should be suitably propped and laterally
restrained during construction. To achieve loading figures, lintels must
be constructed with brickwork (blockwork) fully built-in as shown.
Lintels CNZ94C, CNZ95C, CNZ96C, CNZ97C and CNZ97D should be suitably propped and laterally restrained during construction.
CN48 LintelCNZ96 Lintel
• For 102mm Exterior Solid Walls
CNZ94A
Standard lengths (mm) 750 1350SWL (kN) 8 4Weight (kg/m) 2.7 2.7Nominal height ‘h’ (mm) 88 88
CN48C CN49C
Standard lengths (mm) 750-1800 1950-3000 2850-3000 3300-4800SWL (kN) 15 20 30 20Weight (kg/m) 7.5 9.3 18.0 18.0Nominal height ‘h’ (mm) 154 229 231 231
CNZ94C CNZ97CCNZ96CCNZ95C CNZ97D
Standard lengths (mm) 900-1500 1650-2100 2250-2400 2550-3000 3300-3900SWL (kN) 5 7 10 15 15Weight (kg/m) 4.4 5.4 6.3 7.5 7.5Nominal height ‘h’ (mm) 91 131 167 215 215
CN49D
Single Leaf Wall Lintels
91
h
94
h
Standard DutyStandard Duty Heavy Duty
Standard lengths are available in increments 150mm at lengths up to 3000mm,300mm at lengths 3000mm - 4800mm.
Standard lengths are available in increments of 150mm at lenghts up to 3000mm, 300mm at lengths3000mm - 3900mm.
The SWL (safe working load) is based on the total UDL (uniform
distributed load) over maximum span using 150mm end bearings.
100
55
h
95
70
h
41
Lintels CN48 and CN49 should be suitably propped and laterally
restrained during construction. To achieve loading figures, lintels must
be constructed with brickwork (blockwork) fully built-in as shown.
Lintels CNZ94C, CNZ95C, CNZ96C, CNZ97C and CNZ97D should be suitably propped and laterally restrained during construction.
• For 102mm Exterior Solid Walls
CNZ94A
Standard lengths (mm) 750 1350SWL (kN) 8 4Weight (kg/m) 2.7 2.7Nominal height ‘h’ (mm) 88 88
CN48C CN49C
Standard lengths (mm) 750-1800 1950-3000 2850-3000 3300-4800SWL (kN) 15 20 30 20Weight (kg/m) 7.5 9.1 17.6 17.6Nominal height ‘h’ (mm) 154 229 231 231
CNZ94C CNZ97CCNZ96CCNZ95C CNZ97D
Standard lengths (mm) 900-1500 1650-2100 2250-2400 2550-2700 2850-3000 3300-3900SWL (kN) 5 7 10 15 12 15Weight (kg/m) 4.4 5.4 6.3 7.5 7.5 13.4Nominal height ‘h’ (mm) 91 131 167 215 215 215
CN49D
91
h
94
h
Standard DutyStandard Duty Heavy Duty
Standard lengths are available in increments 150mm at lengths up to 3000mm,300mm at lengths 3000mm - 4800mm (including 4575mm, but excluding 4500mm).
Standard lengths are available in increments of 150mm at lenghts up to 3000mm, 300mm at lengths3000mm - 3900mm.
The SWL (safe working load) is based on the total UDL (uniform
distributed load) over maximum span using 150mm end bearings.
08 Catnic Brochure JAN 09:Layout 1 04/02/2009 10:14 Page 41
Offers a cost effectivesolution for extra light duty loads
ApplicationsCN92 & CN102
Suitable for nominal domestic loading
Integral plaster keyLozenge shaped staggered slots tosides of corrugated profile
Offers a cost effectivesolution for light duty loads
ApplicationsCN100As corrugated lintel plus:Suitable for masonry/timber floor loads.(Note: 1800 & 2100 are not suitable forfloor loads)
Duplex Corrosion Protection SystemEnsures optimum durability andlongevity
Integral plaster keyWith staggered slots to all sides ofchannel profile
Suitable for standard duty loads
ApplicationsCN5X & CN6XUniversal application caters for allloading conditions• Direct floor or roof load• Supports concrete floor loads• Supports point loads
eg. steel beams etc• Optional 4 course profile for high
loads at extended lengths
CN56X & CN66XAs previous plus:• Suitable fro 140mm and 150mm
blockwork
Duplex Corrosion Protection SystemEnsures optimum durability andlongevity
Integral plaster keyWith staggered slots to all sides of boxprofile
Internal Partition & Loadbearing Wall LintelsInternal Partition & Loadbearing Wall Lintels
42
Internal Wall Lintels
CN100 Lintel CN5X LintelCN92 Lintel
43
Catnic lintels for internal partitions and loadbearing wall are available in eithercorrugated, channel or box section to accommodate different loads and openings
Corrugated Channel Box
Standard lengths are available in increments of
150mm at lengths up to 3000mm, 300mm at
lengths from 3000mm – 4800mm (including
4575mm, but excluding 4500mm).
The SWL (safe working load) is based on the total UDL (uniform distributed
load) over maximum span using 150mm end bearings.
Note: When using CN92 and CN102lintels normal building practice shouldbe observed, in that one course ofblockwork should be laid on the linteland the mortar allowed to harden for atleast 24 hours before additional loadsare applied.
• For 100mm Interior Solid Walls
CN92 CN102
Standard lengths (mm) 1050-1200 1050-1200SWL (kN) 7 7Weight (kg/m) 1.2 1.8
CN100
Standard lengths (mm) 1050-1200 1350-1500 1800* 2100*SWL (kN)* 10 13 3 3Weight (kg/m) 4.7 5.9 4.7 4.7Nominal height ‘h’ (mm) 50 73 50 50
• For 100mm Interior Solid Walls
CN5XA CN5XC
Standard lengths (mm) 750-1500 1650-2100 2250-2700 750-1500 1650-1950SWL (kN)* 29 25 20 49 39Weight (kg/m) 7.6 7.6 7.6 12.3 12.3Nominal height ‘h’ (mm) 143 143 143 143 143
CN6XB CN6XC
CN99/438C
Standard lengths (mm) 3000-3300 3600-3900 4200-4800SWL (kN) 54 51 41Weight (kg/m) 19.5 19.5 19.5Nominal height ‘h’ (mm) 295 295 295
CN99/438C
Standard lengths (mm) 3000-3300 3600-3900 4200-4800SWL (kN) 54 51 41Weight (kg/m) 19.5 19.5 19.5Nominal height ‘h’ (mm) 295 295 295
For use in solid or block walls
100
h
Standard lengths (mm) 2100-3600 2100-2700 2850-3300 3600 3900-4575 4800SWL (kN) 29 49 39 34 29 26Weight (kg/m) 12.4 15.7 15.7 15.7 15.7 15.7Nominal height ‘h’ (mm) 219 219 219 219 219 219
68
25
75
98
25
100
103
h
*Not suitable for floor loads
• For 75mm & 100mm Interior Solid WallsExtra Light Duty
Light Duty
Standard Duty Heavy Duty
Standard Duty
Extra Heavy Duty
Heavy Duty
Standard lengths are available in increments of 150mm
Standard lengths are available in increments of 150mm at lengths up to 1500mm, 300mm at lengths from 1800mm - 2100mm.
Offers a cost effectivesolution for extra light duty loads
ApplicationsCN92 & CN102
Suitable for nominal domestic loading
Integral plaster keyLozenge shaped staggered slots tosides of corrugated profile
Offers a cost effectivesolution for light duty loads
ApplicationsCN100As corrugated lintel plus:Suitable for masonry/timber floor loads.(Note: 1800 & 2100 are not suitable forfloor loads)
Duplex Corrosion Protection SystemEnsures optimum durability andlongevity
Integral plaster keyWith staggered slots to all sides ofchannel profile
Suitable for standard duty loads
ApplicationsCN5X & CN6XUniversal application caters for allloading conditions• Direct floor or roof load• Supports concrete floor loads• Supports point loads
eg. steel beams etc• Optional 4 course profile for high
loads at extended lengths
CN56X & CN66XAs previous plus:• Suitable fro 140mm and 150mm
blockwork
Duplex Corrosion Protection SystemEnsures optimum durability andlongevity
Integral plaster keyWith staggered slots to all sides of boxprofile
Internal Partition & Loadbearing Wall LintelsInternal Partition & Loadbearing Wall Lintels
42
Internal Wall Lintels
CN100 Lintel CN5X LintelCN92 Lintel
43
Catnic lintels for internal partitions and loadbearing wall are available in eithercorrugated, channel or box section to accommodate different loads and openings
Corrugated Channel Box
Standard lengths are available in increments of
150mm at lengths up to 3000mm, 300mm at
lengths from 3000mm – 4800mm (including
4575mm, but excluding 4500mm).
The SWL (safe working load) is based on the total UDL (uniform distributed
load) over maximum span using 150mm end bearings.
Note: When using CN92 and CN102lintels normal building practice shouldbe observed, in that one course ofblockwork should be laid on the linteland the mortar allowed to harden for atleast 24 hours before additional loadsare applied.
• For 100mm Interior Solid Walls
CN92 CN102
Standard lengths (mm) 1050-1200 1050-1200SWL (kN) 7 7Weight (kg/m) 1.2 1.8
CN100
Standard lengths (mm) 1050-1200 1350-1500 1800* 2100*SWL (kN)* 10 13 3 3Weight (kg/m) 4.7 5.9 4.7 4.7Nominal height ‘h’ (mm) 50 73 50 50
• For 100mm Interior Solid Walls
CN5XA CN5XC
Standard lengths (mm) 750-1500 1650-2100 2250-2700 750-1500 1650-1950SWL (kN)* 29 25 20 49 39Weight (kg/m) 7.6 7.6 7.6 12.3 12.3Nominal height ‘h’ (mm) 143 143 143 143 143
CN6XB CN6XC
CN99/438C
Standard lengths (mm) 3000-3300 3600-3900 4200-4800SWL (kN) 54 51 41Weight (kg/m) 19.5 19.5 19.5Nominal height ‘h’ (mm) 295 295 295
CN99/438C
Standard lengths (mm) 3000-3300 3600-3900 4200-4800SWL (kN) 54 51 41Weight (kg/m) 19.5 19.5 19.5Nominal height ‘h’ (mm) 295 295 295
For use in solid or block walls
100
h
Standard lengths (mm) 2100-3600 2100-2700 2850-3300 3600 3900-4575 4800SWL (kN) 29 49 39 34 29 26Weight (kg/m) 12.4 15.7 15.7 15.7 15.7 15.7Nominal height ‘h’ (mm) 219 219 219 219 219 219
68
25
75
98
25
100
103
h
*Not suitable for floor loads
• For 75mm & 100mm Interior Solid WallsExtra Light Duty
Light Duty
Standard Duty Heavy Duty
Standard Duty
Extra Heavy Duty
Heavy Duty
Standard lengths are available in increments of 150mm
Standard lengths are available in increments of 150mm at lengths up to 1500mm, 300mm at lengths from 1800mm - 2100mm.
44
CN56X Lintel overdoor opening
Standard lengths are available in increments of 150mm at
lengths up to 3000mm, 300mm at lengths from 3000mm
– 4800mm (including 4575mm, but excluding 4500mm).
Internal Partition & Loadbearing Wall Lintels
• For 140mm & 150mm Interior Solid Walls
CN99/436C
Standard lengths (mm) 3000-3300 3600-3900 4200-4800SWL (kN) 54 51 49Weight (kg/m) 23.0 23.0 23.0Nominal height ‘h’ (mm) 295 295 295
CN66XC
Standard lengths (mm) 1650-2700 2850-3300 3600 3900-4575 4800SWL (kN) 54 47 39 29 26Weight (kg/m) 18.0 18.0 18.0 18.0 18.0Nominal height ‘h’ (mm) 219 219 219 219 219
CN56XA
Standard lengths (mm) 1050-1500 1650-2700SWL (kN) 29 20Weight (kg/m) 9.0 9.0Nominal height ‘h’ (mm) 143 143
The SWL (safe working load) is based on the total UDL (uniform distributed
load) over maximum span using 150mm end bearings.
140
h
Standard Duty
Extra Heavy Duty
Heavy Duty
4544
CN56X Lintel overdoor opening
Standard lengths are available in increments of 150mm at
lengths up to 3000mm, 300mm at lengths from 3000mm
– 4800mm (including 4575mm, but excluding 4500mm).
Stainless Steel LintelsInternal Partition & Loadbearing Wall Lintels
• For 140mm & 150mm Interior Solid Walls
CN99/436C
Standard lengths (mm) 3000-3300 3600-3900 4200-4800SWL (kN) 54 51 49Weight (kg/m) 23.0 23.0 23.0Nominal height ‘h’ (mm) 295 295 295
CN66XC
Standard lengths (mm) 1650-2700 2850-3300 3600 3900-4575 4800SWL (kN) 54 47 39 29 26Weight (kg/m) 18.0 18.0 18.0 18.0 18.0Nominal height ‘h’ (mm) 219 219 219 219 219
CN56XA
Standard lengths (mm) 1050-1500 1650-2700SWL (kN) 29 20Weight (kg/m) 9.0 9.0Nominal height ‘h’ (mm) 143 143
Available in any Catnic lintel profileto accommodate any possible wallconstruction
The standard Duplex corrosion protectionsystem used on Catnic's range of lintelsprovides class leading protection againstcorrosion in all normal circumstances.
However there may be instances when,particularly aggressive environments or to increase the expected life of the lintel, a stainless steel lintel may be required.
Stainless Steel Lintels
a) Non-aggressive EnvironmentBuildings exceeding three storeys in a non-aggressive environment. The material coating specification for products in contact with orembedded in an outer leaf of anexternal cavity wall or a single leafexternal wall should be austeniticstainless steel.
b) Aggressive EnvironmentBuildings located in an aggressiveenvironment (e.g. coastal sites). Thematerial coating specification forproducts in both leaves of externalwalls should be austenitic stainlesssteel.
The outstanding anti-corrosionproperties of stainless steel also make itsuitable for specialist laboratory ormedical applications, hospitals,residential care homes, schools andprisons where the whole life expectancyand maintenance programme becomekey design considerations.
Open Back Lintels
The British Standards 'Code of practice for the use ofmasonry - Part 3: Materials and components, designand workmanship' BS5628-3:2005 implies that the lintelmaterial/coating specifications should be limited toaustenitic stainless steel in two distinct circumstances:
Stainless Steel
Continuous insulation
Plaster key
Built-in DPC profile
Product Range• All Catnic Stainless Steel Lintels are
manufactured from AusteniticStainless Steel, grade 304S15 to BS EN 10088-2-1.4301
• Other grades of stainless steel areavailable on request.
• All Catnic galvanised steel loadingtables apply.
• All stainless steel lintel lengths aremanufactured to order, price anddelivery on application.
• All standard stainless steel lintels fromCatnic are BBA approved underAgrément Certificate No. 91/2638
• Special lintels in stainless steel areavailable manufactured to order.
• All stainless steel lintel products aremanufactured to order.
Special lintel
Box lintel
Timber frame lintel
Single element lintelThe SWL (safe working load) is based on the total UDL (uniform distributed
load) over maximum span using 150mm end bearings.
140
h
Serial Size Weight Depth (D) Width (B) Web Thk (t) Flange Thk (T)(mm) (mm) (mm) (mm) (mm)
PFC2309032 230 x 90 32.2 230.0 90.0 7.5 14.0
Serial Size Weight Depth (D) Width (B) Web Thk (t) Flange Thk (T)(mm) (mm) (mm) (mm) (mm)
UC1515/23 152 x 152 23.0 152.4 152.2 5.8 6.8UC1515/30 152 x 152 30.0 157.6 152.9 6.5 9.4UC2020/46 203 x 203 46.1 203.2 203.6 7.2 11.0UC2525/73 254 254 73.1 254.1 254.6 8.6 14.2
46
Special Lintels
SteelworkWhen loading conditions exceed our standardrange of lintels Catnic offer a selection ofSteelwork beams, columns and channels
D
B
t
T
D
B
t
T
D
B
t
T
Universal Beams (UB)
Serial Size Weight Depth (D) Width (B) Web Thk (t) Flange Thk (T)(mm) (mm) (mm) (mm) (mm)
UB1710/19 178 x 102 19.0 177.8 101.2 4.8 7.9UB2010/23 203 x 102 23.1 203.2 101.8 5.4 9.3UB2013/30 203 x 133 30.0 206.8 133.9 6.4 9.6UB2514/43 254 x 146 43.0 259.6 147.3 7.2 12.7
Universal Columns (UC)
Channels (PFC)
Other standard sections available on request.
Manufactured from grade S275all steelwork sections aresupplied cut to length with holesdrilled as required. A primedfinish is offered as standard withhot dipped post galvanised finishavailable on request.
In addition to the range depicted below Catnic can also accommodate requests for composite bolted beamscomplete with the necessary bolts and spacers.
Catnic Steel sections comply with EN10025:2004:Part 2 – technical delivery conditions for nonalloy structural steels.
Dimensions and properties based on Serial Sizes.
Special Lintels Standard Arch Lintels 48Bespoke Lintels 49
46
Special Lintels
Special Lintels
Steelwork
Catnic is committed to delivering a range of excitingshapes for unique designs and feature brickwork toinspire today’s architects and builders...
...the only constraint is your imagination.
47
When loading conditions exceed our standardrange of lintels Catnic offer a selection ofSteelwork beams, columns and channels
H
W
H
W
H
W
Universal Beams (UB)
Height (mm) Width (mm) Weight (Kg/m)178 102 19203 102 23203 133 30254 146 43
Universal Columns (UC)
Height (mm) Width (mm) Weight (Kg/m)152 152 23152 152 30203 203 46254 254 73
Channels (PFC)
Height (mm) Width (mm) Weight (Kg/m)230 90 32
Catnic Steel sections comply with EN10025:2004:Part 2 – technical delivery conditions for nonalloy structural steels.
Dimensions and properties based on Serial Sizes.
Other standard sections available on request.
Manufactured from grade S275all steelwork sections aresupplied cut to length with holesdrilled as required. A primedfinish is offered as standard withhot dipped post galvanised finishavailable on request.
In addition to the range depicted below Catnic can also accommodate requests for composite bolted beamscomplete with the necessary bolts and spacers.
245
Clear Span
150
150
285
Clear Span
150
150
150
Special LintelsSpecial Lintels
4948
Arches When you want to make a feature ofbrickwork you may need more than astandard lintel, so Catnic offers bothstandard and innovative bespoke designs
When a building requires a more unconventionalsupport solution, Catnic is again, one step ahead andhas an experienced feature design engineer dedicatedto providing innovative design solutions to achieve thearchitect’s vision
Bespoke Designs
Lintel Clear Span WeightType (mm) (kg)
CCA/600 600 11.79CCA/630 630 12.26CCA/900 900 16.53CCA/915 915 16.77CCA/1200 1200 21.37
Application
102115-125
102102
50-8550-65
3
3
20mm maximumoverhang
Application
102115-125
102102
90-10070-85
Outer Leaf Inner Leaf
3
3
20mm maximumoverhang
20mm maximumoverhang
20mm maximumoverhang
Standard semi-circular arches available for
domestic housing applications. For alternative
cavity and masonry widths, please contact our
Technical Services Department.
Typical application showingsemi-circular arched lintel infacing brickwork
Naturally, Catnic’s technical supportteam has the breadth of knowledgeand expertise to design lintels for themost creative of openings, with in-house facilities and skill tomanufacture fabricated lintels to suitcountless configurations.
Various styles of bay window, gothicand apex arches, bulls-eye and cornerfeature lintels for domestic andcommercial applications are handwelded and post galvanised for extracorrosion protection, assuring lasting quality.
Although the majority of arches aresemi-circular, Catnic also offer gothicarches for Victorian styled buildingsand apex designs for triangular ordiamond shaped openings, curvedon-plan for bays, in curved walls andalso elliptical, parabolic, Arabian andsegmental. The list is endless andthere are limitless variations which Catnic have the capacity to fabricatevirtually any arch specificationrequired.
A fast and cost effective fabricationservice from a unique and specialisedfabrication facility – means thatbespoke lintels can often be deliveredalong with standard lintels minimisingdelays on site. Each lintel, as always,is manufactured to a high qualitystandard; hot dip galvanised aftermanufacture to BS EN ISO 1461:1999
Feature lintelsWhile your imagination runs wild withcreative openings, why not beinventive with brickwork too?
Catnic has the expertise to designand manufacture lintels for decorativebrick and stone work, for examplereduced toe lintels for discrete usewith cant bricks.
All arch lintels require a separateDPC installed over
Catnic have a standard range of ten semi-circular arches specificallydesigned and manufactured fordomestic housing applications withnominal loadings. These arches offerconsiderable flexibility for featurebrickwork with clear spans rangingfrom 600mm to 1200mm and areavailable from stock.
For alternative cavity and masonrywidths to those shown, pleasecontact our Technical ServicesDepartment on 029 2033 7900.
Lintel Clear Span WeightType (mm) (kg)
CCB/600 600 12.96CCB/630 630 13.47CCB/900 900 18.14CCB/915 915 18.40CCB/1200 1200 23.43
150
Standard Arch Lintels
245
Clear Span
150
150
285
Clear Span
150
150
150
Special LintelsSpecial Lintels
4948
Arches When you want to make a feature ofbrickwork you may need more than astandard lintel, so Catnic offers bothstandard and innovative bespoke designs
When a building requires a more unconventionalsupport solution, Catnic is again, one step ahead andhas an experienced feature design engineer dedicatedto providing innovative design solutions to achieve thearchitect’s vision
Bespoke Designs
Lintel Clear Span WeightType (mm) (kg)
CCA/600 600 11.79CCA/630 630 12.26CCA/900 900 16.53CCA/915 915 16.77CCA/1200 1200 21.37
Application
102115-125
102102
50-8550-65
3
3
20mm maximumoverhang
Application
102115-125
102102
90-10070-85
Outer Leaf Inner Leaf
3
3
20mm maximumoverhang
20mm maximumoverhang
20mm maximumoverhang
Standard semi-circular arches available for
domestic housing applications. For alternative
cavity and masonry widths, please contact our
Technical Services Department.
Typical application showingsemi-circular arched lintel infacing brickwork
Naturally, Catnic’s technical supportteam has the breadth of knowledgeand expertise to design lintels for themost creative of openings, with in-house facilities and skill tomanufacture fabricated lintels to suitcountless configurations.
Various styles of bay window, gothicand apex arches, bulls-eye and cornerfeature lintels for domestic andcommercial applications are handwelded and post galvanised for extracorrosion protection, assuring lasting quality.
Although the majority of arches aresemi-circular, Catnic also offer gothicarches for Victorian styled buildingsand apex designs for triangular ordiamond shaped openings, curvedon-plan for bays, in curved walls andalso elliptical, parabolic, Arabian andsegmental. The list is endless andthere are limitless variations which Catnic have the capacity to fabricatevirtually any arch specificationrequired.
A fast and cost effective fabricationservice from a unique and specialisedfabrication facility – means thatbespoke lintels can often be deliveredalong with standard lintels minimisingdelays on site. Each lintel, as always,is manufactured to a high qualitystandard; hot dip galvanised aftermanufacture to BS EN ISO 1461:1999
Feature lintelsWhile your imagination runs wild withcreative openings, why not beinventive with brickwork too?
Catnic has the expertise to designand manufacture lintels for decorativebrick and stone work, for examplereduced toe lintels for discrete usewith cant bricks.
All arch lintels require a separateDPC installed over
Catnic have a standard range of ten semi-circular arches specificallydesigned and manufactured fordomestic housing applications withnominal loadings. These arches offerconsiderable flexibility for featurebrickwork with clear spans rangingfrom 600mm to 1200mm and areavailable from stock.
For alternative cavity and masonrywidths to those shown, pleasecontact our Technical ServicesDepartment on 029 2033 7900.
Lintel Clear Span WeightType (mm) (kg)
CCB/600 600 12.96CCB/630 630 13.47CCB/900 900 18.14CCB/915 915 18.40CCB/1200 1200 23.43
150
Standard Arch Lintels
51
If you require furtherinformation pleasetel: 029 2033 7900.
The apex lintel enables the creation of triangular or diamondshaped openings. Commonly used with high vaulted ceilingsenhancing the flood of daylight and perception of grandeur.
All Catnic special fabricated lintels are hot-dip galvanised aftermanufacture for complete protection from corrosion,eliminating the need for on-site painting or maintenance.
Apex lintels are available in 10 working days from receipt oforder and approved drawing.
Please complete the form below and submit to TechnicalServices on Fax: 087 0024 1809 to request a quotation.
Special Lintels - Apex Arch Lintel
51
E A E
H
Customer Address
Name*
Address
Post Code Tel*
Email* Fax
* Mandatory Fields
Site Address
Name
Address
Post Code Tel
Email Fax
Plaster Key Requirements*
Inside Only Both Sides None
Wall Construction
Outer leaf (mm)* Cavity (mm)* Inner leaf (mm)*
Application details (leave blank if unknown/inapplicable)
Masonry Height (mm) Roof Span (mm)
Timber Floor Concrete Floor
Load (leave blank if unknown)
Inner leaf (kN per metre) Outer leaf (kN per metre)
Lintel Dimensions
Clearspan - A (mm)* Height of rise - H (mm)* End bearing - E (mm)*
50
If you require furtherinformation pleasetel: 029 2033 7900.
The ace of clubs arch lintel enables the architect to fashion aunique window opening that will create the ultimate feature forany room. The ace of clubs arch is formed from three radii thatcan be equal or with the centre arch being greater than theother two.
All Catnic special fabricated lintels are hot-dip galvanised aftermanufacture for complete protection from corrosion,eliminating the need for on-site painting or maintenance.
Ace of clubs arch lintels are available in 10 working days fromreceipt of order and approved drawing.
Please complete the form below and submit to TechnicalServices on Fax: 087 0024 1809 to request a quotation.
50
Special Lintels - Ace of Clubs Arch Lintel
Lintel Dimensions
Clearspan - A (mm)* Height of rise - H (mm)*
End bearing - E (mm)* Radius 1 - R1 (degrees)*
Radius 2 - R2 (degrees)* Radius 3 - R3 (degrees)*
R2
R3
H
E A E
R1
Customer Address
Name*
Address
Post Code Tel*
Email* Fax
* Mandatory Fields
Site Address
Name
Address
Post Code Tel
Email Fax
Wall Construction
Outer leaf (mm)* Cavity (mm)* Inner leaf (mm)*
Application details (leave blank if unknown/inapplicable)
Masonry Height (mm) Roof Span (mm)
Timber Floor Concrete Floor
Load (leave blank if unknown)
Inner leaf (kN per metre) Outer leaf (kN per metre)
Plaster Key Requirements*
Inside Only Both Sides NoneNOTE: All times quoted as working days, include delivery, calculated from receipt of order
and approved drawing (where applicable). All products are subject to availability.
NOTE: All times quoted as working days, include delivery, calculated from receipt of orderand approved drawing (where applicable). All products are subject to availability.
51
If you require furtherinformation pleasetel: 029 2033 7900.
The apex lintel enables the creation of triangular or diamondshaped openings. Commonly used with high vaulted ceilingsenhancing the flood of daylight and perception of grandeur.
All Catnic special fabricated lintels are hot-dip galvanised aftermanufacture for complete protection from corrosion,eliminating the need for on-site painting or maintenance.
Apex lintels are available in 10 working days from receipt oforder and approved drawing.
Please complete the form below and submit to TechnicalServices on Fax: 087 0024 1809 to request a quotation.
Special Lintels - Apex Arch Lintel
51
E A E
H
Customer Address
Name*
Address
Post Code Tel*
Email* Fax
* Mandatory Fields
Site Address
Name
Address
Post Code Tel
Email Fax
Plaster Key Requirements*
Inside Only Both Sides None
Wall Construction
Outer leaf (mm)* Cavity (mm)* Inner leaf (mm)*
Application details (leave blank if unknown/inapplicable)
Masonry Height (mm) Roof Span (mm)
Timber Floor Concrete Floor
Load (leave blank if unknown)
Inner leaf (kN per metre) Outer leaf (kN per metre)
Lintel Dimensions
Clearspan - A (mm)* Height of rise - H (mm)* End bearing - E (mm)*
50
If you require furtherinformation pleasetel: 029 2033 7900.
The ace of clubs arch lintel enables the architect to fashion aunique window opening that will create the ultimate feature forany room. The ace of clubs arch is formed from three radii thatcan be equal or with the centre arch being greater than theother two.
All Catnic special fabricated lintels are hot-dip galvanised aftermanufacture for complete protection from corrosion,eliminating the need for on-site painting or maintenance.
Ace of clubs arch lintels are available in 10 working days fromreceipt of order and approved drawing.
Please complete the form below and submit to TechnicalServices on Fax: 087 0024 1809 to request a quotation.
50
Special Lintels - Ace of Clubs Arch Lintel
Lintel Dimensions
Clearspan - A (mm)* Height of rise - H (mm)*
End bearing - E (mm)* Radius 1 - R1 (degrees)*
Radius 2 - R2 (degrees)* Radius 3 - R3 (degrees)*
R2
R3
H
E A E
R1
Customer Address
Name*
Address
Post Code Tel*
Email* Fax
* Mandatory Fields
Site Address
Name
Address
Post Code Tel
Email Fax
Wall Construction
Outer leaf (mm)* Cavity (mm)* Inner leaf (mm)*
Application details (leave blank if unknown/inapplicable)
Masonry Height (mm) Roof Span (mm)
Timber Floor Concrete Floor
Load (leave blank if unknown)
Inner leaf (kN per metre) Outer leaf (kN per metre)
Plaster Key Requirements*
Inside Only Both Sides NoneNOTE: All times quoted as working days, include delivery, calculated from receipt of order
and approved drawing (where applicable). All products are subject to availability.
NOTE: All times quoted as working days, include delivery, calculated from receipt of orderand approved drawing (where applicable). All products are subject to availability.
If you require furtherinformation pleasetel: 029 2033 7900.Special Lintels - Corner Lintel
Lintel Dimensions
A (mm)* B (mm)* Angle (degrees)*
The mitre and welded corner lintel enables the appearance ofan unspoiled window openings on two perpendicular walls of aroom. Corner lintels come complete with support posts (spigotpost) and base plate. Support posts are available in standardlengths to allow for site cutting to actual requirements.
All Catnic special fabricated lintels, spigot posts and baseplates are hot-dip galvanised after manufacture for complete
protection from corrosion, eliminating the need for on-sitepainting or maintenance.
Corner lintels are available in 10 working days from receipt oforder and approved drawing.
Please complete the form below and submit to TechnicalServices on Fax: 087 0024 1809 to request a quotation.
Customer Address
Name*
Address
Post Code Tel*
Email* Fax
* Mandatory Fields
Site Address
Name
Address
Post Code Tel
Email Fax
Wall Construction
Outer leaf (mm)* Cavity (mm)* Inner leaf (mm)*
Application details (leave blank if unknown/inapplicable)
Masonry Height (mm) Roof Span (mm)
Timber Floor Concrete Floor
Load (leave blank if unknown)
Inner leaf (kN per metre) Outer leaf (kN per metre)
Plaster Key Requirements*
Inside Only Both Sides None
53
If you require furtherinformation pleasetel: 029 2033 7900.
Lintel Dimensions
Clearspan - A (mm)* Height of rise - H (mm)* End bearing - E (mm)*
Special Lintels - Bull’s Eye LintelThe bulls-eye lintel enables the creation of round, circular andspherical window openings and portholes.
All Catnic special fabricated lintels are hot-dip galvanised aftermanufacture for complete protection from corrosion,eliminating the need for on-site painting or maintenance.
Bulls-eye lintels are available in 10 working days from receiptof order and approved drawing.
Please complete the form below and submit to TechnicalServices on Fax: 087 0024 1809 to request a quotation.
E
H
E
A
Customer Address
Name*
Address
Post Code Tel*
Email* Fax
* Mandatory Fields
Site Address
Name
Address
Post Code Tel
Email Fax
Wall Construction
Outer leaf (mm)* Cavity (mm)* Inner leaf (mm)*
Application details (leave blank if unknown/inapplicable)
Masonry Height (mm) Roof Span (mm)
Timber Floor Concrete Floor
Load (leave blank if unknown)
Inner leaf (kN per metre) Outer leaf (kN per metre)
Plaster Key Requirements*
Inside Only Both Sides None
52
NOTE: All times quoted as working days, include delivery, calculated from receipt of orderand approved drawing (where applicable). All products are subject to availability.
NOTE: All times quoted as working days, include delivery, calculated from receipt of orderand approved drawing (where applicable). All products are subject to availability.
Support Posts* (please tick length required).
n/a 1000mm 1500mm
2000mm 2500mm 3000mmSupport posts cut to length on site.
A
Angle°
B
Do not allow for endbearings, this will becalculated by CatnicTechnical Services.
If you require furtherinformation pleasetel: 029 2033 7900.Special Lintels - Corner Lintel
Lintel Dimensions
A (mm)* B (mm)* Angle (degrees)*
The mitre and welded corner lintel enables the appearance ofan unspoiled window openings on two perpendicular walls of aroom. Corner lintels come complete with support posts (spigotpost) and base plate. Support posts are available in standardlengths to allow for site cutting to actual requirements.
All Catnic special fabricated lintels, spigot posts and baseplates are hot-dip galvanised after manufacture for complete
protection from corrosion, eliminating the need for on-sitepainting or maintenance.
Corner lintels are available in 10 working days from receipt oforder and approved drawing.
Please complete the form below and submit to TechnicalServices on Fax: 087 0024 1809 to request a quotation.
Customer Address
Name*
Address
Post Code Tel*
Email* Fax
* Mandatory Fields
Site Address
Name
Address
Post Code Tel
Email Fax
Wall Construction
Outer leaf (mm)* Cavity (mm)* Inner leaf (mm)*
Application details (leave blank if unknown/inapplicable)
Masonry Height (mm) Roof Span (mm)
Timber Floor Concrete Floor
Load (leave blank if unknown)
Inner leaf (kN per metre) Outer leaf (kN per metre)
Plaster Key Requirements*
Inside Only Both Sides None
53
NOTE: All times quoted as working days, include delivery, calculated from receipt of orderand approved drawing (where applicable). All products are subject to availability.
Support Posts* (please tick length required).
n/a 1000mm 1500mm
2000mm 2500mm 3000mmSupport posts cut to length on site.
A
Angle°
B
Do not allow for endbearings, this will becalculated by CatnicTechnical Services.
NOTE: All times quoted as working days, include delivery, calculated from receipt of orderand approved drawing (where applicable). All products are subject to availability.
NOTE: All times quoted as working days, include delivery, calculated from receipt of orderand approved drawing (where applicable). All products are subject to availability.
If you require furtherinformation pleasetel: 029 2033 7900.Special Lintels - Elliptical Arch Lintel
Lintel Dimensions
Clearspan - A (mm)* Height of rise - H (mm)* End bearing - E (mm)*
The elliptical arch lintel enables the creation of a wider,shallower arch opening compared to that offered by thetraditional steeper semi-circular arch. The elliptical arch isformed by multiple arcs each of which is drawn from its owncentre compared to a roman arch which is a semi-circular arcdrawn from a single centre point.
All Catnic special fabricated lintels are hot-dip galvanised aftermanufacture for complete protection from corrosion,eliminating the need for on-site painting or maintenance.
Elliptical arch lintels are available in 10 working days fromreceipt of order and approved drawing.
Please complete the form below and submit to TechnicalServices on Fax: 087 0024 1809 to request a quotation.
H
E A E
Customer Address
Name*
Address
Post Code Tel*
Email* Fax
* Mandatory Fields
Site Address
Name
Address
Post Code Tel
Email Fax
Wall Construction
Outer leaf (mm)* Cavity (mm)* Inner leaf (mm)*
Application details (leave blank if unknown/inapplicable)
Masonry Height (mm) Roof Span (mm)
Timber Floor Concrete Floor
Load (leave blank if unknown)
Inner leaf (kN per metre) Outer leaf (kN per metre)
Plaster Key Requirements*
Inside Only Both Sides None
55
Lintel Dimensions
Clearspan - A (mm) Outshot - O (mm)
Customer Address
Name*
Address
Post Code Tel*
Email* Fax
* Mandatory Fields
Site Address
Name
Address
Post Code Tel
Email Fax
If you require furtherinformation pleasetel: 029 2033 7900.Special Lintels - Curved On Plan Lintel
The curved on plan lintel (sometimes known as radius lintel orbow lintel) enables the creation of curved walls with openings.Curved lintels can be manufactured to suit customer specifiedradii.
All Catnic special fabricated lintels are hot-dip galvanised aftermanufacture for complete protection from corrosion,eliminating the need for on-site painting or maintenance.
Curved lintels are available in 10 working days from receipt oforder and approved drawing.
Please complete the form below and submit to TechnicalServices on Fax: 087 0024 1809 to request a quotation.
A
O
Wall Construction
Outer leaf (mm)* Cavity (mm)* Inner leaf (mm)*
Application details (leave blank if unknown/inapplicable)
Masonry Height (mm) Roof Span (mm)
Timber Floor Concrete Floor
Load (leave blank if unknown)
Inner leaf (kN per metre) Outer leaf (kN per metre)
Plaster Key Requirements*
Inside Only Both Sides None
54
Do not allow for endbearings, this will becalculated by CatnicTechnical Services.
NOTE: All times quoted as working days, include delivery, calculated from receipt of orderand approved drawing (where applicable). All products are subject to availability.
NOTE: All times quoted as working days, include delivery, calculated from receipt of orderand approved drawing (where applicable). All products are subject to availability.
If you require furtherinformation pleasetel: 029 2033 7900.Special Lintels - Elliptical Arch Lintel
Lintel Dimensions
Clearspan - A (mm)* Height of rise - H (mm)* End bearing - E (mm)*
The elliptical arch lintel enables the creation of a wider,shallower arch opening compared to that offered by thetraditional steeper semi-circular arch. The elliptical arch isformed by multiple arcs each of which is drawn from its owncentre compared to a roman arch which is a semi-circular arcdrawn from a single centre point.
All Catnic special fabricated lintels are hot-dip galvanised aftermanufacture for complete protection from corrosion,eliminating the need for on-site painting or maintenance.
Elliptical arch lintels are available in 10 working days fromreceipt of order and approved drawing.
Please complete the form below and submit to TechnicalServices on Fax: 087 0024 1809 to request a quotation.
H
E A E
Customer Address
Name*
Address
Post Code Tel*
Email* Fax
* Mandatory Fields
Site Address
Name
Address
Post Code Tel
Email Fax
Wall Construction
Outer leaf (mm)* Cavity (mm)* Inner leaf (mm)*
Application details (leave blank if unknown/inapplicable)
Masonry Height (mm) Roof Span (mm)
Timber Floor Concrete Floor
Load (leave blank if unknown)
Inner leaf (kN per metre) Outer leaf (kN per metre)
Plaster Key Requirements*
Inside Only Both Sides None
55
Lintel Dimensions
Clearspan - A (mm) Outshot - O (mm)
Customer Address
Name*
Address
Post Code Tel*
Email* Fax
* Mandatory Fields
Site Address
Name
Address
Post Code Tel
Email Fax
If you require furtherinformation pleasetel: 029 2033 7900.Special Lintels - Curved On Plan Lintel
The curved on plan lintel (sometimes known as radius lintel orbow lintel) enables the creation of curved walls with openings.Curved lintels can be manufactured to suit customer specifiedradii.
All Catnic special fabricated lintels are hot-dip galvanised aftermanufacture for complete protection from corrosion,eliminating the need for on-site painting or maintenance.
Curved lintels are available in 10 working days from receipt oforder and approved drawing.
Please complete the form below and submit to TechnicalServices on Fax: 087 0024 1809 to request a quotation.
A
O
Wall Construction
Outer leaf (mm)* Cavity (mm)* Inner leaf (mm)*
Application details (leave blank if unknown/inapplicable)
Masonry Height (mm) Roof Span (mm)
Timber Floor Concrete Floor
Load (leave blank if unknown)
Inner leaf (kN per metre) Outer leaf (kN per metre)
Plaster Key Requirements*
Inside Only Both Sides None
54
Do not allow for endbearings, this will becalculated by CatnicTechnical Services.
57
If you require furtherinformation pleasetel: 029 2033 7900.
If you require furtherinformation pleasetel: 029 2033 7900.Special Lintels - Parabolic Arch LintelSpecial Lintels - Gothic Arch Lintel
The parabolic arch lintel enables the creation of openings withan artistically distinctive softer curvature than offered by atraditional, elliptical or gothic arch. The parabolic arch isformed by the creation of an arch in the form of theintersection of a cone with a plane parallel to the side of thecone, like a three-centred arch.
To construct a parabolic curve please see the illustration below.
All Catnic special fabricated lintels are hot-dip galvanised aftermanufacture for complete protection from corrosion,eliminating the need for on-site painting or maintenance.
Parabolic arch lintels are available in 10 working days fromreceipt of order and approved drawing.
Please complete the form below and submit to TechnicalServices on Fax: 087 0024 1809 to request a quotation.
The gothic arch lintel enables the creation of pointed windowand door openings to complement strong vertical lines, highvaulted ceilings, minimal wall space, and buttressed wallsoften found in Victorian and gothic architecture. Gothic orpointed arches are formed from two segmental arches leaningtogether to form a point.
All Catnic special fabricated lintels are hot-dip galvanised aftermanufacture for complete protection from corrosion,eliminating the need for on-site painting or maintenance.
Gothic arch lintels are available in 10 working days fromreceipt of order and approved drawing.
Please complete the form below and submit to TechnicalServices on Fax: 087 0024 1809 to request a quotation.
E A E
H
R
H
E A E
A
DE
F
C
B
R
r
1
Lintel Dimensions
Clearspan - A (mm)* Height of rise - H (mm)*
End bearing - E (mm)* Radius - R (degrees)*
Wall Construction
Outer leaf (mm)* Cavity (mm)* Inner leaf (mm)*
Application details (leave blank if unknown/inapplicable)
Masonry Height (mm) Roof Span (mm)
Timber Floor Concrete Floor
Load (leave blank if unknown)
Inner leaf (kN per metre) Outer leaf (kN per metre)
Lintel Dimensions
Clearspan - A (mm)* Height of rise - H (mm)* End bearing - E (mm)*
Wall Construction
Outer leaf (mm)* Cavity (mm)* Inner leaf (mm)*
Application details (leave blank if unknown/inapplicable)
Masonry Height (mm) Roof Span (mm)
Timber Floor Concrete Floor
Load (leave blank if unknown)
Inner leaf (kN per metre) Outer leaf (kN per metre)
Customer Address
Name*
Address
Post Code Tel*
Email* Fax
* Mandatory Fields
Site Address
Name
Address
Post Code Tel
Email Fax
Customer Address
Name*
Address
Post Code Tel*
Email* Fax
* Mandatory Fields
Site Address
Name
Address
Post Code Tel
Email Fax
Plaster Key Requirements*
Inside Only Both Sides None
Plaster Key Requirements*
Inside Only Both Sides None
56
NOTE: All times quoted as working days, include delivery, calculated from receipt of orderand approved drawing (where applicable). All products are subject to availability.
NOTE: All times quoted as working days, include delivery, calculated from receipt of orderand approved drawing (where applicable). All products are subject to availability.
57
If you require furtherinformation pleasetel: 029 2033 7900.
If you require furtherinformation pleasetel: 029 2033 7900.Special Lintels - Parabolic Arch LintelSpecial Lintels - Gothic Arch Lintel
The parabolic arch lintel enables the creation of openings withan artistically distinctive softer curvature than offered by atraditional, elliptical or gothic arch. The parabolic arch isformed by the creation of an arch in the form of theintersection of a cone with a plane parallel to the side of thecone, like a three-centred arch.
To construct a parabolic curve please see the illustration below.
All Catnic special fabricated lintels are hot-dip galvanised aftermanufacture for complete protection from corrosion,eliminating the need for on-site painting or maintenance.
Parabolic arch lintels are available in 10 working days fromreceipt of order and approved drawing.
Please complete the form below and submit to TechnicalServices on Fax: 087 0024 1809 to request a quotation.
The gothic arch lintel enables the creation of pointed windowand door openings to complement strong vertical lines, highvaulted ceilings, minimal wall space, and buttressed wallsoften found in Victorian and gothic architecture. Gothic orpointed arches are formed from two segmental arches leaningtogether to form a point.
All Catnic special fabricated lintels are hot-dip galvanised aftermanufacture for complete protection from corrosion,eliminating the need for on-site painting or maintenance.
Gothic arch lintels are available in 10 working days fromreceipt of order and approved drawing.
Please complete the form below and submit to TechnicalServices on Fax: 087 0024 1809 to request a quotation.
E A E
H
R
H
E A E
A
DE
F
C
B
R
r
1
Lintel Dimensions
Clearspan - A (mm)* Height of rise - H (mm)*
End bearing - E (mm)* Radius - R (degrees)*
Wall Construction
Outer leaf (mm)* Cavity (mm)* Inner leaf (mm)*
Application details (leave blank if unknown/inapplicable)
Masonry Height (mm) Roof Span (mm)
Timber Floor Concrete Floor
Load (leave blank if unknown)
Inner leaf (kN per metre) Outer leaf (kN per metre)
Lintel Dimensions
Clearspan - A (mm)* Height of rise - H (mm)* End bearing - E (mm)*
Wall Construction
Outer leaf (mm)* Cavity (mm)* Inner leaf (mm)*
Application details (leave blank if unknown/inapplicable)
Masonry Height (mm) Roof Span (mm)
Timber Floor Concrete Floor
Load (leave blank if unknown)
Inner leaf (kN per metre) Outer leaf (kN per metre)
Customer Address
Name*
Address
Post Code Tel*
Email* Fax
* Mandatory Fields
Site Address
Name
Address
Post Code Tel
Email Fax
Customer Address
Name*
Address
Post Code Tel*
Email* Fax
* Mandatory Fields
Site Address
Name
Address
Post Code Tel
Email Fax
Plaster Key Requirements*
Inside Only Both Sides None
Plaster Key Requirements*
Inside Only Both Sides None
56
NOTE: All times quoted as working days, include delivery, calculated from receipt of orderand approved drawing (where applicable). All products are subject to availability.
NOTE: All times quoted as working days, include delivery, calculated from receipt of orderand approved drawing (where applicable). All products are subject to availability.
If you require furtherinformation pleasetel: 029 2033 7900.Special Lintels - Semi-Circular Arch Lintel
The semi-circular arch lintel is the most common featurebrickwork opening providing a classical design line for anywindow or door. Catnic have 10 different size semi-circulararch lintels available from stock. For alternative cavity andmasonry widths please complete the below enquiry form.
All Catnic special fabricated lintels are hot-dip galvanised aftermanufacture for complete protection from corrosion,eliminating the need for on-site painting or maintenance.
Semi-circular arch lintels are available in 10 working days fromreceipt of order and approved drawing.
Please complete the form below and submit to TechnicalServices on Fax: 087 0024 1809 to request a quotation.
E A
H
E
Lintel Dimensions
Clearspan - A (mm)* Height of rise - H (mm)* End bearing - E (mm)*
Wall Construction
Outer leaf (mm)* Cavity (mm)* Inner leaf (mm)*
Application details (leave blank if unknown/inapplicable)
Masonry Height (mm) Roof Span (mm)
Timber Floor Concrete Floor
Load (leave blank if unknown)
Inner leaf (kN per metre) Outer leaf (kN per metre)
Customer Address
Name*
Address
Post Code Tel*
Email* Fax
* Mandatory Fields
Site Address
Name
Address
Post Code Tel
Email Fax
Plaster Key Requirements*
Inside Only Both Sides None
59
If you require furtherinformation pleasetel: 029 2033 7900.
Lintel Dimensions
Clearspan - A (mm)* Height of rise - H (mm)* End bearing - E (mm)*
Special Lintels - Segmental Arch LintelThe segmental arch lintel enables the creation of an openingwhere the arch whose profile comprises an arc smaller than asemicircle. The segmental arch is made up of part of a circle,the centre of which is below its springing line.
All Catnic special fabricated lintels are hot-dip galvanised aftermanufacture for complete protection from corrosion,eliminating the need for on-site painting or maintenance.
Segmental arch lintels are available in 10 working days fromreceipt of order and approved drawing.
Please complete the form below and submit to TechnicalServices on Fax: 087 0024 1809 to request a quotation.
E A E
H
Wall Construction
Outer leaf (mm)* Cavity (mm)* Inner leaf (mm)*
Application details (leave blank if unknown/inapplicable)
Masonry Height (mm) Roof Span (mm)
Timber Floor Concrete Floor
Load (leave blank if unknown)
Inner leaf (kN per metre) Outer leaf (kN per metre)
Customer Address
Name*
Address
Post Code Tel*
Email* Fax
* Mandatory Fields
Site Address
Name
Address
Post Code Tel
Email Fax
Plaster Key Requirements*
Inside Only Both Sides None
58
NOTE: All times quoted as working days, include delivery, calculated from receipt of orderand approved drawing (where applicable). All products are subject to availability.
NOTE: All times quoted as working days, include delivery, calculated from receipt of orderand approved drawing (where applicable). All products are subject to availability.
If you require furtherinformation pleasetel: 029 2033 7900.Special Lintels - Semi-Circular Arch Lintel
The semi-circular arch lintel is the most common featurebrickwork opening providing a classical design line for anywindow or door. Catnic have 10 different size semi-circulararch lintels available from stock. For alternative cavity andmasonry widths please complete the below enquiry form.
All Catnic special fabricated lintels are hot-dip galvanised aftermanufacture for complete protection from corrosion,eliminating the need for on-site painting or maintenance.
Semi-circular arch lintels are available in 10 working days fromreceipt of order and approved drawing.
Please complete the form below and submit to TechnicalServices on Fax: 087 0024 1809 to request a quotation.
E A
H
E
Lintel Dimensions
Clearspan - A (mm)* Height of rise - H (mm)* End bearing - E (mm)*
Wall Construction
Outer leaf (mm)* Cavity (mm)* Inner leaf (mm)*
Application details (leave blank if unknown/inapplicable)
Masonry Height (mm) Roof Span (mm)
Timber Floor Concrete Floor
Load (leave blank if unknown)
Inner leaf (kN per metre) Outer leaf (kN per metre)
Customer Address
Name*
Address
Post Code Tel*
Email* Fax
* Mandatory Fields
Site Address
Name
Address
Post Code Tel
Email Fax
Plaster Key Requirements*
Inside Only Both Sides None
59
If you require furtherinformation pleasetel: 029 2033 7900.
Lintel Dimensions
Clearspan - A (mm)* Height of rise - H (mm)* End bearing - E (mm)*
Special Lintels - Segmental Arch LintelThe segmental arch lintel enables the creation of an openingwhere the arch whose profile comprises an arc smaller than asemicircle. The segmental arch is made up of part of a circle,the centre of which is below its springing line.
All Catnic special fabricated lintels are hot-dip galvanised aftermanufacture for complete protection from corrosion,eliminating the need for on-site painting or maintenance.
Segmental arch lintels are available in 10 working days fromreceipt of order and approved drawing.
Please complete the form below and submit to TechnicalServices on Fax: 087 0024 1809 to request a quotation.
E A E
H
Wall Construction
Outer leaf (mm)* Cavity (mm)* Inner leaf (mm)*
Application details (leave blank if unknown/inapplicable)
Masonry Height (mm) Roof Span (mm)
Timber Floor Concrete Floor
Load (leave blank if unknown)
Inner leaf (kN per metre) Outer leaf (kN per metre)
Customer Address
Name*
Address
Post Code Tel*
Email* Fax
* Mandatory Fields
Site Address
Name
Address
Post Code Tel
Email Fax
Plaster Key Requirements*
Inside Only Both Sides None
58
NOTE: All times quoted as working days, include delivery, calculated from receipt of orderand approved drawing (where applicable). All products are subject to availability.
NOTE: All times quoted as working days, include delivery, calculated from receipt of orderand approved drawing (where applicable). All products are subject to availability.
61
If you require furtherinformation pleasetel: 029 2033 7900.Special Lintels - Splayed Bay Lintel
Lintel Dimensions
A (mm)* B (mm)*
C (mm)* Angle (degrees)*
NOTE: All times quoted as working days, include delivery, calculated from receipt of orderand approved drawing (where applicable). All products are subject to availability.
NOTE: All times quoted as working days, include delivery, calculated from receipt of orderand approved drawing (where applicable). All products are subject to availability.
The splayed bay lintel with bearings projects the wall forwardfrom the confines of the rest of the room to create an openingthat attempts to make use of every last ray of sunshine.Introduced during the Georgian period, made popular inVictorian times and carried on in Edwardian housing the baywindow is a realisation by architects that windows with threeaspects could improve the outlook of living rooms.Splayed bay lintels come complete with support posts (spigotpost) and base plate. Support posts are available in standardlengths to allow for site cutting to actual requirements.
All Catnic special fabricated lintels, spigot posts and baseplates are hot-dip galvanised after manufacture for completeprotection from corrosion, eliminating the need for on-sitepainting or maintenance.Splayed bay lintels are available in 10 working days fromreceipt of order and approved drawing.Please complete the form below and submit to TechnicalServices on Fax: 087 0024 1809 to request a quotation.
Wall Construction
Outer leaf (mm)* Cavity (mm)* Inner leaf (mm)*
Application details (leave blank if unknown/inapplicable)
Masonry Height (mm) Roof Span (mm)
Timber Floor Concrete Floor
Load (leave blank if unknown)
Inner leaf (kN per metre) Outer leaf (kN per metre)
Customer Address
Name*
Address
Post Code Tel*
Email* Fax
* Mandatory Fields
Site Address
Name
Address
Post Code Tel
Email Fax
Plaster Key Requirements*
Inside Only Both Sides None
with returnbearings
60
If you require furtherinformation pleasetel: 029 2033 7900.Special Lintels - Splayed Bay Lintel
Lintel Dimensions
A (mm)* B (mm)*
C (mm)* Angle (degrees)*
The splayed bay lintel projects the wall forward from theconfines of the rest of the room to create an opening thatattempts to make use of every last ray of sunshine. Introducedduring the Georgian period, made popular in Victorian timesand carried on in Edwardian housing the bay window is arealisation by architects that windows with three aspects couldimprove the outlook of living rooms.Splayed bay lintels come complete with support posts (spigotpost) and base plate. Support posts are available in standardlengths to allow for site cutting to actual requirements.
All Catnic special fabricated lintels, spigot posts and baseplates are hot-dip galvanised after manufacture for completeprotection from corrosion, eliminating the need for on-sitepainting or maintenance.Splayed bay lintels are available in 10 working days fromreceipt of order and approved drawing.Please complete the form below and submit to TechnicalServices on Fax: 087 0024 1809 to request a quotation.
Wall Construction
Outer leaf (mm)* Cavity (mm)* Inner leaf (mm)*
Application details (leave blank if unknown/inapplicable)
Masonry Height (mm) Roof Span (mm)
Timber Floor Concrete Floor
Load (leave blank if unknown)
Inner leaf (kN per metre) Outer leaf (kN per metre)
Customer Address
Name*
Address
Post Code Tel*
Email* Fax
* Mandatory Fields
Site Address
Name
Address
Post Code Tel
Email Fax
Plaster Key Requirements*
Inside Only Both Sides None
Support Posts* (please tick length required).
n/a 1000mm 1500mm
2000mm 2500mm 3000mmSupport posts cut to length on site.
Support Posts* (please tick length required).
n/a 1000mm 1500mm
2000mm 2500mm 3000mmSupport posts cut to length on site.
B
CA
Angle°
B
CA
Angle°
Do not allow for endbearings, this will becalculated by CatnicTechnical Services.
Do not allow for endbearings, this will becalculated by CatnicTechnical Services.
61
If you require furtherinformation pleasetel: 029 2033 7900.Special Lintels - Splayed Bay Lintel
Lintel Dimensions
A (mm)* B (mm)*
C (mm)* Angle (degrees)*
NOTE: All times quoted as working days, include delivery, calculated from receipt of orderand approved drawing (where applicable). All products are subject to availability.
NOTE: All times quoted as working days, include delivery, calculated from receipt of orderand approved drawing (where applicable). All products are subject to availability.
The splayed bay lintel with bearings projects the wall forwardfrom the confines of the rest of the room to create an openingthat attempts to make use of every last ray of sunshine.Introduced during the Georgian period, made popular inVictorian times and carried on in Edwardian housing the baywindow is a realisation by architects that windows with threeaspects could improve the outlook of living rooms.Splayed bay lintels come complete with support posts (spigotpost) and base plate. Support posts are available in standardlengths to allow for site cutting to actual requirements.
All Catnic special fabricated lintels, spigot posts and baseplates are hot-dip galvanised after manufacture for completeprotection from corrosion, eliminating the need for on-sitepainting or maintenance.Splayed bay lintels are available in 10 working days fromreceipt of order and approved drawing.Please complete the form below and submit to TechnicalServices on Fax: 087 0024 1809 to request a quotation.
Wall Construction
Outer leaf (mm)* Cavity (mm)* Inner leaf (mm)*
Application details (leave blank if unknown/inapplicable)
Masonry Height (mm) Roof Span (mm)
Timber Floor Concrete Floor
Load (leave blank if unknown)
Inner leaf (kN per metre) Outer leaf (kN per metre)
Customer Address
Name*
Address
Post Code Tel*
Email* Fax
* Mandatory Fields
Site Address
Name
Address
Post Code Tel
Email Fax
Plaster Key Requirements*
Inside Only Both Sides None
with returnbearings
60
If you require furtherinformation pleasetel: 029 2033 7900.Special Lintels - Splayed Bay Lintel
Lintel Dimensions
A (mm)* B (mm)*
C (mm)* Angle (degrees)*
The splayed bay lintel projects the wall forward from theconfines of the rest of the room to create an opening thatattempts to make use of every last ray of sunshine. Introducedduring the Georgian period, made popular in Victorian timesand carried on in Edwardian housing the bay window is arealisation by architects that windows with three aspects couldimprove the outlook of living rooms.Splayed bay lintels come complete with support posts (spigotpost) and base plate. Support posts are available in standardlengths to allow for site cutting to actual requirements.
All Catnic special fabricated lintels, spigot posts and baseplates are hot-dip galvanised after manufacture for completeprotection from corrosion, eliminating the need for on-sitepainting or maintenance.Splayed bay lintels are available in 10 working days fromreceipt of order and approved drawing.Please complete the form below and submit to TechnicalServices on Fax: 087 0024 1809 to request a quotation.
Wall Construction
Outer leaf (mm)* Cavity (mm)* Inner leaf (mm)*
Application details (leave blank if unknown/inapplicable)
Masonry Height (mm) Roof Span (mm)
Timber Floor Concrete Floor
Load (leave blank if unknown)
Inner leaf (kN per metre) Outer leaf (kN per metre)
Customer Address
Name*
Address
Post Code Tel*
Email* Fax
* Mandatory Fields
Site Address
Name
Address
Post Code Tel
Email Fax
Plaster Key Requirements*
Inside Only Both Sides None
Support Posts* (please tick length required).
n/a 1000mm 1500mm
2000mm 2500mm 3000mmSupport posts cut to length on site.
Support Posts* (please tick length required).
n/a 1000mm 1500mm
2000mm 2500mm 3000mmSupport posts cut to length on site.
B
CA
Angle°
B
CA
Angle°
Do not allow for endbearings, this will becalculated by CatnicTechnical Services.
Do not allow for endbearings, this will becalculated by CatnicTechnical Services.
NOTE: All times quoted as working days, include delivery, calculated from receipt of orderand approved drawing (where applicable). All products are subject to availability.
NOTE: All times quoted as working days, include delivery, calculated from receipt of orderand approved drawing (where applicable). All products are subject to availability.
Support Posts* (please tick length required).
n/a 1000mm 1500mm
2000mm 2500mm 3000mmSupport posts cut to length on site.
63
If you require furtherinformation pleasetel: 029 2033 7900.Special Lintels - Venetian Arch Lintel
Lintel Dimensions
Clearspan - A1 (mm)* Archspan - A2 (mm)*
Height of rise - H (mm)* End Bearing - E (mm)*
The Venetian arch lintel enables the formation of a classicdesign consisting of a three-part window composed of a large,arched central section flanked by two narrower, shortersections having square tops.
All Catnic special fabricated lintels are hot-dip galvanised aftermanufacture for complete protection from corrosion,eliminating the need for on-site painting or maintenance.
Venetian arch lintels are available in 10 working days fromreceipt of order and approved drawing.
Please complete the form below and submit to TechnicalServices on Fax: 087 0024 1809 to request a quotation.
R
E Overall Clear Span A1
Arch Span A2
H
E
Wall Construction
Outer leaf (mm)* Cavity (mm)* Inner leaf (mm)*
Application details (leave blank if unknown/inapplicable)
Masonry Height (mm) Roof Span (mm)
Timber Floor Concrete Floor
Load (leave blank if unknown)
Inner leaf (kN per metre) Outer leaf (kN per metre)
Customer Address
Name*
Address
Post Code Tel*
Email* Fax
* Mandatory Fields
Site Address
Name
Address
Post Code Tel
Email Fax
Plaster Key Requirements*
Inside Only Both Sides None
62
If you require furtherinformation pleasetel: 029 2033 7900.Special Lintels - Square Bay Lintel
Lintel Dimensions
A (mm)* B (mm)*
C (mm)* Angle (degrees)*
The square bay lintel uses perpendicular returns (90º angle)compared to the splayed bay lintel (greater than 90º angle) tocreate a window opening with three aspects. Square baylintels come complete with support posts (spigot post) andbase plate. Support posts are available in standard lengths toallow for site cutting to actual requirements.
All Catnic special fabricated lintels, spigot posts and baseplates are hot-dip galvanised after manufacture for completeprotection from corrosion, eliminating the need for on-sitepainting or maintenance.
Square bay lintels are available in 10 working days fromreceipt of order and approved drawing.
Please complete the form below and submit to TechnicalServices on Fax: 087 0024 1809 to request a quotation.
B
CA
Angle°
Wall Construction
Outer leaf (mm)* Cavity (mm)* Inner leaf (mm)*
Application details (leave blank if unknown/inapplicable)
Masonry Height (mm) Roof Span (mm)
Timber Floor Concrete Floor
Load (leave blank if unknown)
Inner leaf (kN per metre) Outer leaf (kN per metre)
Customer Address
Name*
Address
Post Code Tel*
Email* Fax
* Mandatory Fields
Site Address
Name
Address
Post Code Tel
Email Fax
Plaster Key Requirements*
Inside Only Both Sides None
Do not allow for endbearings, this will becalculated by CatnicTechnical Services.
NOTE: All times quoted as working days, include delivery, calculated from receipt of orderand approved drawing (where applicable). All products are subject to availability.
NOTE: All times quoted as working days, include delivery, calculated from receipt of orderand approved drawing (where applicable). All products are subject to availability.
Support Posts* (please tick length required).
n/a 1000mm 1500mm
2000mm 2500mm 3000mmSupport posts cut to length on site.
63
If you require furtherinformation pleasetel: 029 2033 7900.Special Lintels - Venetian Arch Lintel
Lintel Dimensions
Clearspan - A1 (mm)* Archspan - A2 (mm)*
Height of rise - H (mm)* End Bearing - E (mm)*
The Venetian arch lintel enables the formation of a classicdesign consisting of a three-part window composed of a large,arched central section flanked by two narrower, shortersections having square tops.
All Catnic special fabricated lintels are hot-dip galvanised aftermanufacture for complete protection from corrosion,eliminating the need for on-site painting or maintenance.
Venetian arch lintels are available in 10 working days fromreceipt of order and approved drawing.
Please complete the form below and submit to TechnicalServices on Fax: 087 0024 1809 to request a quotation.
R
E Overall Clear Span A1
Arch Span A2
H
E
Wall Construction
Outer leaf (mm)* Cavity (mm)* Inner leaf (mm)*
Application details (leave blank if unknown/inapplicable)
Masonry Height (mm) Roof Span (mm)
Timber Floor Concrete Floor
Load (leave blank if unknown)
Inner leaf (kN per metre) Outer leaf (kN per metre)
Customer Address
Name*
Address
Post Code Tel*
Email* Fax
* Mandatory Fields
Site Address
Name
Address
Post Code Tel
Email Fax
Plaster Key Requirements*
Inside Only Both Sides None
62
If you require furtherinformation pleasetel: 029 2033 7900.Special Lintels - Square Bay Lintel
Lintel Dimensions
A (mm)* B (mm)*
C (mm)* Angle (degrees)*
The square bay lintel uses perpendicular returns (90º angle)compared to the splayed bay lintel (greater than 90º angle) tocreate a window opening with three aspects. Square baylintels come complete with support posts (spigot post) andbase plate. Support posts are available in standard lengths toallow for site cutting to actual requirements.
All Catnic special fabricated lintels, spigot posts and baseplates are hot-dip galvanised after manufacture for completeprotection from corrosion, eliminating the need for on-sitepainting or maintenance.
Square bay lintels are available in 10 working days fromreceipt of order and approved drawing.
Please complete the form below and submit to TechnicalServices on Fax: 087 0024 1809 to request a quotation.
B
CA
Angle°
Wall Construction
Outer leaf (mm)* Cavity (mm)* Inner leaf (mm)*
Application details (leave blank if unknown/inapplicable)
Masonry Height (mm) Roof Span (mm)
Timber Floor Concrete Floor
Load (leave blank if unknown)
Inner leaf (kN per metre) Outer leaf (kN per metre)
Customer Address
Name*
Address
Post Code Tel*
Email* Fax
* Mandatory Fields
Site Address
Name
Address
Post Code Tel
Email Fax
Plaster Key Requirements*
Inside Only Both Sides None
Do not allow for endbearings, this will becalculated by CatnicTechnical Services.
65
Lintel Soffit Cladding – Type RC and FC
For improved protectionLintel Soffit Cladding also providesextra protection, especially in coastalregions, and in situations where muchof the lintel soffit is exposed.
For improved appearanceAn optional cladding, particularlysuitable for use with PVC-U windows.The cladding was originally designedto give a more aesthetically pleasingappearance to rebated combined boxlintels.
These advantages have now beenextended to cover all flush soffitlintels.
MaterialA PVC-U pre-cut unit, supplied inwhite (FC & RC) or brown (FC only).
Important noteAll external wall lintels fitted with lintelcladding must be installed with aflexible damp proof course (DPC)ensuring that the DPC projects beyondthe front face of the cladding.
Lintel Soffit Cladding type RC & FC, comein 96mm/108mm widths respectively
Lintel Soffit Cladding type RC
Lintel Soffit Cladding type FC
Lintel Soffit Cladding type FC
Accessories Soffit Cladding 65Arch Centres 66Stop Ends 67Weep Vents 68External Plaster Key 69
64
AccessoriesCatnic is committed to offer a range of high qualityaccessories to enhance the performance of Catnicsteel lintels and to make their application even easier
64
65
Lintel Soffit Cladding – Type RC and FC
For improved protectionLintel Soffit Cladding also providesextra protection, especially in coastalregions, and in situations where muchof the lintel soffit is exposed.
For improved appearanceAn optional cladding, particularlysuitable for use with PVC-U windows.The cladding was originally designedto give a more aesthetically pleasingappearance to rebated combined boxlintels.
These advantages have now beenextended to cover all flush soffitlintels.
MaterialA PVC-U pre-cut unit, supplied inwhite (FC & RC) or brown (FC only).
Important noteAll external wall lintels fitted with lintelcladding must be installed with aflexible damp proof course (DPC)ensuring that the DPC projects beyondthe front face of the cladding.
Lintel Soffit Cladding type RC & FC, comein 96mm/108mm widths respectively
Lintel Soffit Cladding type FC
Lintel Soffit Cladding type FC
Lintel Soffit Cladding type RC
66
Lintel ArchCentres – Type AC
For the construction of segmentalarches in brickwork.A vacuum formed arch unit for use overopenings in external cavity walls –traditional and timber frame – providingpermanent centering for brick archconstruction.
Made under licence British Patent No.2063953.
• Allows easy construction of segmentalarches
• Includes integral weep vent
MaterialVacuum formed from HIPS (Satin HighImpact Polystyrene). The underside of theArchCentre incorporates a minimum of 2built-in weep vents. For longer lengthspans additional weep vents are included,at maximum spacings of 900mm.
Installation notesi) Do not use damaged ArchCentres.
ii) Remove the ArchCentre from its protective wrapping. iii) Check that the ArchCentre is correct for application (Refer to
the lintel specification).iv) Ensure the ArchCentre and lintel mounting surfaces are clean
and dry.v) Locate the unit centrally over the opening to determine the
position on the lintel. The front drip section should be trimmed off at the bearing end to allow for thin mortar jointsand to enhance the appearance.
vi) Locate the unit on the lintel at position previouslydetermined, ensuring a tight fit to the edge of lintel toe.
Lintel ArchCentre
Important noteIf used with Catnic soffit cladding, thestraight ends of the ArchCentre (seecross-hatching on illustration, left), whichextend beyond the structural opening,should be removed before proceeding tostage vi. (see below)
This operation can also be carried out toavoid exposing the drip edge of theArchCentre within the mortar joint at thebearing end. Cutting into the main body ofthe ArchCentre should not be carried out.
ArchCentre ArchCentre StructuralCode Span (mm) Opening (mm) Rise (mm)ACA0475 475 450-500 75ACA0625 625 600-650 75ACA0925 925 900-950 75ACA1050 1050 1025-1075 75ACA1225 1225 1200-1250 75ACA1350 1350 1325-1375 75ACA1485 1485 1460-1510 75ACA1625 1625 1600-1650 75ACA1700 1700 1675-1725 75ACA1785 1785 1760-1810 75ACB1975 1975 1950-2000 150ACB2125 2125 2100-2150 150ACA2250 2250 2225-2275 75ACB2325 2325 2300-2350 150ACB2425 2425 2400-2450 150
ACA - 75mmACB - 150mm
ArchCentre Span
NoteSpecial ArchCentres available - for details please call our TechnicalServices Department on 029 2033 7900
66 67
Lintel ArchCentres – Type AC
For the construction of segmentalarches in brickwork.A vacuum formed arch unit for use overopenings in external cavity walls –traditional and timber frame – providingpermanent centering for brick archconstruction.
Made under licence British Patent No.2063953.
• Allows easy construction of segmentalarches
• Includes integral weep vent
MaterialVacuum formed from HIPS (Satin HighImpact Polystyrene). The underside of theArchCentre incorporates a minimum of 2built-in weep vents. For longer lengthspans additional weep vents are included,at maximum spacings of 900mm.
Installation notesi) Do not use damaged ArchCentres.
ii) Remove the ArchCentre from its protective wrapping. iii) Check that the ArchCentre is correct for application (Refer to
the lintel specification).iv) Ensure the ArchCentre and lintel mounting surfaces are clean
and dry.v) Locate the unit centrally over the opening to determine the
position on the lintel. The front drip section should be trimmed off at the bearing end to allow for thin mortar jointsand to enhance the appearance.
vi) Locate the unit on the lintel at position previouslydetermined, ensuring a tight fit to the edge of lintel toe.
Lintel ArchCentre
Important noteIf used with Catnic soffit cladding, thestraight ends of the ArchCentre (seecross-hatching on illustration, left), whichextend beyond the structural opening,should be removed before proceeding tostage vi. (see below)
This operation can also be carried out toavoid exposing the drip edge of theArchCentre within the mortar joint at thebearing end. Cutting into the main body ofthe ArchCentre should not be carried out.
ArchCentre ArchCentre StructuralCode Span (mm) Opening (mm) Rise (mm)ACA0475 475 450-500 75ACA0625 625 600-650 75ACA0925 925 900-950 75ACA1050 1050 1025-1075 75ACA1225 1225 1200-1250 75ACA1350 1350 1325-1375 75ACA1485 1485 1460-1510 75ACA1625 1625 1600-1650 75ACA1700 1700 1675-1725 75ACA1785 1785 1760-1810 75ACB1975 1975 1950-2000 150ACB2125 2125 2100-2150 150ACA2250 2250 2225-2275 75ACB2325 2325 2300-2350 150ACB2425 2425 2400-2450 150
ACA - 75mmACB - 150mm
ArchCentre Span
Figure 2: Lintel Stop End type C90 for use with CGlintels and external solid lintels
Figure 1: Lintel Stop End type CL3 for use withcombined lintels or CH & CX lintels
Lintel Stop Ends – Type CL3 and C90
For eliminating problems associatedwith moisture penetration.Wind-driven rain that penetrates theexternal skin of a cavity wall will,under normal conditions, discharge offthe ends of conventional lintels.
However, with full fill cavity insulation,and in areas of severe exposure, largevolumes of water can be releasedfrom lintel ends into and throughinsulation, creating dampness atinternal reveals. Catnic Stop Endsprevent this problem.
Use CL3 Stop Ends (see Figure 1) forlintels with a fully inclined face within thecavity (combined lintels or CH & CX lintels).
Use C90 Stop Ends (see Figure 2) for alllintels with a 90˚ brickwork/ blockworksupport flange (for use with Cougar CGlintels)
Technical requirementsNHBC Standards: Where fair facedmasonry is supported by lintels: cavitytrays or combined lintels should haveStop Ends.
Zurich Municipal: To prevent waterrunning into the adjacent cavity, cavitytrays should have 75mm deep Stop
Ends located to coincide with theperpend nearest to the end of thecavity tray.
MaterialDurrpolyethylene 6/A for type CL3.BS polypropylene for type C90.
Important noteCavity weep holes should be providedover all lintels fitted with Stop Ends.Stop Ends type CL3 can be applied tolintels designed for cavity wallconstruction with a maximum 100mmcavity, although they will suit cavitiesup to 150mm wide, providing the lintelupstand rises to 225mm.
Installation notesi) Ensure the lintel surface is clean and
dry.
ii) Remove the protective covering to thelength of the anchoring strip on thebottom of the Stop Ends.
iii) Position to suit the perpendicular jointnearest the lintel ends, ensuring thatthe base and back of the Stop End fit snugly into the front upstand of the lintel face.
NoteSpecial ArchCentres available - fordetails please call our TechnicalServices Department on 029 2033 7900
68
Cavity Weep Vents – Type WV
For ensuring removal of water from cavities.DPC and cavity tray installations overopenings require weeps to dischargecollected water from the cavity above.Cavity Weep Vents also assist indraining interstitial condensation,
which can contribute to moisturetracking across the cavity. The designof Cavity Weep Vents type WV alsoprovides an aesthetically pleasingsolution, as the front face of the WeepVent blends unobtrusively into themasonry.
Technical requirementsNHBC Standards 1995: Where fair facedmasonry is supported by lintels: weepholes should be provided at maximum450mm intervals. Each opening shouldhave at least two weep holes.
Zurich Municipal: In localities ofmoderate exposure or worse, or where full cavity fill is used, cavity trays should be adequately drained throughweep holes spaced at no more than 1metre apart, with at least 2 peropening.
MaterialBS Polypropylene in grey, beige andterracotta to match mortar.
Important noteCavity weep holes should be providedover all lintels fitted with stop ends
Cavity Weep Vent type WV available interracotta, beige and grey
Installation notesi) Position in the perpendicular brick
directly above the lintel.ii) Use a minimum of 2 per lintel at
450mm maximum centres.
External Plaster Key
ApplicationSuitable for use with Cougar lintels (CG, CH, CX) timber frame lintels (CTF5, CTF7, CTF9, CN23) and Externalsolid wall lintels (CN71 & CN81).
InstallationExternal plasterkey simply clips into placeand is secured using a full length ofadhesive bead (supplied by others).
StorageUnless required
immediate use on site theproduct should be stored in a
clean dry environment.
Type PKS87Manufactured from galvanised steel to BS EN 10327:2004 of grade DX51D+Z275the external plaster key provides a securekey for a rendered finish.
69
Installation notesi) Ensure plaster key mounting surface
and under side of lintel is clean, dryand free from grease and dirt.
ii) Locate plaster key centrally overlintel (refer to illustration above todetermine the position on lintel).
iii) Apply a 6mm bead of adhesive alongthe full length of plaster key inaccordance with adhesivemanufactureres instructions.
iv) Locate the plaster key against thetoe of the lintel at the positionpreviously determined and rotateonto lintel, (refer to illustration),apply downward pressure to ensurefull adhesive contact to bothsurfaces.
v) Pull surfaces apart to allow adhesiveto dry for 10-15 minutes.
vi) Reposition the plaster key onto thelintel base (as step iv) applyinguniform pressure over the lintellength.
vii) A strong initial bond is achievedwhilst full bond strength results in48-72 hours.
External Plaster Key
ApplicationSuitable for use with Cougar lintels (CG, CH, CX) timber frame lintels (CTF5, CTF7, CTF9, CN23) and Externalsolid wall lintels (CN71 & CN81).
InstallationExternal plasterkey simply clips into placeand is secured using a full length ofadhesive bead (supplied by others).
StorageUnless required
immediate use on site theproduct should be stored in a
clean dry environment.
Type PKS87Manufactured from galvanised steel to BS EN 10327:2004 of grade DX51D+Z275the external plaster key provides a securekey for a rendered finish.
69
Installation notesi) Ensure plaster key mounting surface
and under side of lintel is clean, dryand free from grease and dirt.
ii) Locate plaster key centrally overlintel (refer to illustration above todetermine the position on lintel).
iii) Apply a 6mm bead of adhesive alongthe full length of plaster key inaccordance with adhesivemanufactureres instructions.
iv) Locate the plaster key against thetoe of the lintel at the positionpreviously determined and rotateonto lintel, apply downward pressureto ensure full adhesive contact toboth surfaces.
v) Pull surfaces apart to allow adhesiveto dry for 10-15 minutes.
vi) Reposition the plaster key onto thelintel base (as step iv) applyinguniform pressure over the lintellength.
vii) A strong initial bond is achievedwhilst full bond strength results in48-72 hours.
717070
Installation GuidesCatnic is committed to trouble free installation
Installation Installing a cavity wall lintel 71Installing a lintel supporting a concrete floor 73Installing a timber frame lintel 74
70
Installing a Cavity Wall Lintel
In cavity walls, raise inner and outer
leaves supported by lintel together.†Ensure wall dimensions are correct.
Ensure that masonry overhang
does not exceed 25mm.
Masonry above lintels should be allowed
to cure before applying floor or roof loads.
Ensure lintel is level along its width.
Ensure lintel is fully beddedon bricklaying mortar.
Ensure lintel is level along its length.
Structural opening or clear span.
* For advice on installations where end bearings can be reduced to not less than 100mm, pleasecontact Catnic Technical Services Department on 029 2033 7900.
† Ensure no more than half the safe working load(SWL) is carried by the outer leaf where the lintelcarries an external cavity wall. The wall should alsobe restrained laterally near the top.
Outer LeafInner Leaf Cavity
Ensure a nominal150mm end bearingat each end.*
Do• Install a separate DPC in severe exposure conditions.
A Catnic Cougar Open Back lintel with an additional DPCmembrane installed in accordance with normal practiceprovides the best possible protection (page 76)
• Locate the window/door frame so that the drip on the frontof the lintel projects forward of the drip on the front of theframe. It is good building practice to insert a flexible jointbetween the lintel and the top of the frame
• Ensure that timber floor joists and roof trusses have a fullblock depth between them and the lintel flange on CougarOpen Back Lintels
• Refer to the Catnic ‘How to Install a Lintel SupportingConcrete Floors’ or the Steel Lintel ManufacturersAssociation guidelines (available on request) when using CH& CX Open Back Lintels to support concrete floors
• Consider the use of our soffit cladding for all coastal sites(refer to page 65)
Do not• Use damaged lintels
• Apply point loads without prior consultation. Where theloading or a substantial part of it is applied as concentratedloads, each concentrated load must be supported over alength of lintel of not less than 200mm. In such cases, thetotal loading must not produce bending moments or shearforces greater than those produced by the uniformlydistributed loads specified in the relevant data tables
• Allow blockwork to overhang the lintel by more than 25mm
• Apply concrete floor loads without ensuring that the total loads are checked by a structural engineer, or by CatnicTechnical Services
• Do not cut CG type lintels under any circumstances
• Apply point loads directly on lintel flanges
Ensure lintel isnot damaged.
717070
Installation GuidesCatnic is committed to trouble free installation
Installation Installing a cavity wall lintel 71Installing a lintel supporting a concrete floor 73Installing a timber frame lintel 74
70
Installing a Cavity Wall Lintel
In cavity walls, raise inner and outer
leaves supported by lintel together.†Ensure wall dimensions are correct.
Ensure that masonry overhang
does not exceed 25mm.
Masonry above lintels should be allowed
to cure before applying floor or roof loads.
Ensure lintel is level along its width.
Ensure lintel is fully beddedon bricklaying mortar.
Ensure lintel is level along its length.
Structural opening or clear span.
* For advice on installations where end bearings can be reduced to not less than 100mm, pleasecontact Catnic Technical Services Department on 029 2033 7900.
† Ensure no more than half the safe working load(SWL) is carried by the outer leaf where the lintelcarries an external cavity wall. The wall should alsobe restrained laterally near the top.
Outer LeafInner Leaf Cavity
Ensure a nominal150mm end bearingat each end.*
Do• Install a separate DPC in severe exposure conditions.
A Catnic Cougar Open Back lintel with an additional DPCmembrane installed in accordance with normal practiceprovides the best possible protection (page 76)
• Locate the window/door frame so that the drip on the frontof the lintel projects forward of the drip on the front of theframe. It is good building practice to insert a flexible jointbetween the lintel and the top of the frame
• Ensure that timber floor joists and roof trusses have a fullblock depth between them and the lintel flange on CougarOpen Back Lintels
• Refer to the Catnic ‘How to Install a Lintel SupportingConcrete Floors’ or the Steel Lintel ManufacturersAssociation guidelines (available on request) when using CH& CX Open Back Lintels to support concrete floors
• Consider the use of our soffit cladding for all coastal sites(refer to page 65)
Do not• Use damaged lintels
• Apply point loads without prior consultation. Where theloading or a substantial part of it is applied as concentratedloads, each concentrated load must be supported over alength of lintel of not less than 200mm. In such cases, thetotal loading must not produce bending moments or shearforces greater than those produced by the uniformlydistributed loads specified in the relevant data tables
• Allow blockwork to overhang the lintel by more than 25mm
• Apply concrete floor loads without ensuring that the total loads are checked by a structural engineer, or by CatnicTechnical Services
• Do not cut CG type lintels under any circumstances
• Apply point loads directly on lintel flanges
Ensure lintel isnot damaged.
12515
Prop if necessary
• Check that the correct lintel is beingused according to the manufacturer’slintel schedule/design criteria
• Bed the lintel on full blocks and allowmortar to cure before applyingconcrete floor loads
• Raise both leaves of cavity walltogether and allow masonry to curesufficiently before applying heavyloads. Alternatively prop the lintel iflarge loads are to be applied to freshmasonry
• When using the Catnic CH & CXOpen back range with concretefloors, always ensure that theblockwork is built tight against theinner vertical face of the lintel, andthat a mortar joint is added to the topof the blockwork so that the floorunits have an even spread over theinner flange of the lintel
• Avoid shock loading lintels during theinstallation of concrete floor units andalso any sideways loading whilebeing lifted into position
• Precast flooring units should be laidon a mortar bearing of the full innerleaf wall width and should not be dragged over supports
• Avoid loading newly laid floors withbuilding materials
• Lintels must be built-in as illustrated,ensuring that the blockwork infill iswell-jointed during construction andcompatible with the strength of themasonry above
i.e. one row of blocks should be raised on the inner leaf, thenthree courses of brick on the outer leaf. Wall ties should thenbe installed and another row of blocks on the inner leaffollowed by three courses of brick on the outer and so on.
This process ensures that the lintel flanges are equally loadedand helps prevent rotation.
The open back lintel should also be suitably propped duringconstruction when being used with wide dense blocks.
Propping
• When propping, a horizontal boardshould be placed along the undersideof the lintel soffit, this will prevent anypoint loading, which could causelocalised deformation of the lintel.On small openings a single propshould be placed centrally within theopenings and wedged into place.The prop can be removed after thewall ties are effective. The number ofprops used should be increased forlarger openings.
• The 140 mm dense blocks should beinstalled tight against the inner webof the lintel.
• Therefore, the overhang of blockworkon the lintels inner flange could bemeasured at 15mm.
• If after considering the aboveinformation it is not practicable tocarry out the mentioned constructionprocess on site, we are able to offeran alternative box style lintel in placeof open back. These products aremore robust due to the design of thebox section and therefore, open togreater abuse on site during theconstruction stage.
Installing a Lintel Supporting Concrete Floors
Typical CX Lintel, supporting a concrete floor
Concrete floor
Lintel
Brick outer leaf
Block inner leaf
In addition to the Cavity Wall Installation Guide, please read the following for installing concretefloors with Catnic steel lintels
To ensure the flanges are equally loadedthe Code of Practice should be strictlyadhered to when building the masonry
Open Back - Wide Inner Leaf lintels used with 140mm dense blocks
7372
Installing a Cavity Wall Lintel
Continuoussolid infill block
Prop centrally for spans up to2100mm. For larger spans useprops at 1200mm centres.
12515
Prop if necessary
• Check that the correct lintel is beingused according to the manufacturer’slintel schedule/design criteria
• Bed the lintel on full blocks and allowmortar to cure before applyingconcrete floor loads
• Raise both leaves of cavity walltogether and allow masonry to curesufficiently before applying heavyloads. Alternatively prop the lintel iflarge loads are to be applied to freshmasonry
• When using the Catnic CH & CXOpen back range with concretefloors, always ensure that theblockwork is built tight against theinner vertical face of the lintel, andthat a mortar joint is added to the topof the blockwork so that the floorunits have an even spread over theinner flange of the lintel
• Avoid shock loading lintels during theinstallation of concrete floor units andalso any sideways loading whilebeing lifted into position
• Precast flooring units should be laidon a mortar bearing of the full innerleaf wall width and should not be dragged over supports
• Avoid loading newly laid floors withbuilding materials
• Lintels must be built-in as illustrated,ensuring that the blockwork infill iswell-jointed during construction andcompatible with the strength of themasonry above
i.e. one row of blocks should be raised on the inner leaf, thenthree courses of brick on the outer leaf. Wall ties should thenbe installed and another row of blocks on the inner leaffollowed by three courses of brick on the outer and so on.
This process ensures that the lintel flanges are equally loadedand helps prevent rotation.
The open back lintel should also be suitably propped duringconstruction when being used with wide dense blocks.
Propping
• When propping, a horizontal boardshould be placed along the undersideof the lintel soffit, this will prevent anypoint loading, which could causelocalised deformation of the lintel.On small openings a single propshould be placed centrally within theopenings and wedged into place.The prop can be removed after thewall ties are effective. The number ofprops used should be increased forlarger openings.
• The 140 mm dense blocks should beinstalled tight against the inner webof the lintel.
• Therefore, the overhang of blockworkon the lintels inner flange could bemeasured at 15mm.
• If after considering the aboveinformation it is not practicable tocarry out the mentioned constructionprocess on site, we are able to offeran alternative box style lintel in placeof open back. These products aremore robust due to the design of thebox section and therefore, open togreater abuse on site during theconstruction stage.
Installing a Lintel Supporting Concrete Floors
Typical CX Lintel, supporting a concrete floor
Concrete floor
Lintel
Brick outer leaf
Block inner leaf
In addition to the Cavity Wall Installation Guide, please read the following for installing concretefloors with Catnic steel lintels
To ensure the flanges are equally loadedthe Code of Practice should be strictlyadhered to when building the masonry
Open Back - Wide Inner Leaf lintels used with 140mm dense blocks
7372
Installing a Cavity Wall Lintel
Continuoussolid infill block
Prop centrally for spans up to2100mm. For larger spans useprops at 1200mm centres.
7574
Installing a Timber Frame Lintel
• When propping, a horizontal boardshould be placed along the flatunderside of the lintel soffit; this willprevent any point loading, whichcould cause localised deformation ofthe lintel flange.
• On small openings a single prop shouldbe placed centrally within the openingand gently wedged into place.
• The number of props should beincreased for larger openings.Generally props should be installed atmaximum centres of 1 metre.
• The prop can be removed after themortar has cured and the wall tiesbecome effective.
• A timber pinch batten should be fixedat the heel of the timber frame lintel inorder to minimise any rotation.
• Catnic timber frame lintels (e.g. CTF’s) are intended only tosupport an outer skin of brickworkwhere it is tied to an inner skin oftimber frame and must be suitablypropped during construction.
Note: lintels should be suitably propped during construction.Lintels for timber frame construction are supplied with lintelrestraint clips (free of charge), which must be screw or nailfixed to the timber frame to allow for differential movementbetween the timber structure and the brick facing.
Overall lintel length
300
max
300
max
600
max
600
max
Centre of lintel
Position of lintel restraint clips
Screw fixing
Nail fixing
Clearance
Clearance
Lintel code Length (mm) Clip fixingsCTF5, 7 & 9 750-3600 50mm x 3.35mm diam. Plain head galvanised nailsCTF5, 7 & 9 3900-4800 38mm x No10 RD/HD sherardised wood screwsCN23 Up to 4800 38mm x No10 RD/HD sherardised wood screws
Lintel NumberLength (mm) of clipsUp to 1800 31950-3000 53300-4200 74575-4800 9
Typical application showing lintel over window
In addition to the Cavity Wall Installation Guide,please read the following for Catnic timberframe lintel installation
Technical Specifications & Quality AssurancesCatnic is committed to providing architects, designersand builders with useful information and terminologyrelevant to the specification of Catnic lintels
Specifications Where to use a separate DPC 76Quality Assurance 77Technical Information 78The Environment 79Guide to safe storage and handling 80Material Specification 81Glossary of technical terms 82
7574
Installing a Timber Frame Lintel
• When propping, a horizontal boardshould be placed along the flatunderside of the lintel soffit; this willprevent any point loading, whichcould cause localised deformation ofthe lintel flange.
• On small openings a single prop shouldbe placed centrally within the openingand gently wedged into place.
• The number of props should beincreased for larger openings.Generally props should be installed atmaximum centres of 1 metre.
• The prop can be removed after themortar has cured and the wall tiesbecome effective.
• A timber pinch batten should be fixedat the heel of the timber frame lintel inorder to minimise any rotation.
• Catnic timber frame lintels (e.g. CTF’s) are intended only tosupport an outer skin of brickworkwhere it is tied to an inner skin oftimber frame and must be suitablypropped during construction.
Note: lintels should be suitably propped during construction.Lintels for timber frame construction are supplied with lintelrestraint clips (free of charge), which must be screw or nailfixed to the timber frame to allow for differential movementbetween the timber structure and the brick facing.
Overall lintel length
300
max
300
max
600
max
600
max
Centre of lintel
Position of lintel restraint clips
Screw fixing
Nail fixing
Clearance
Clearance
Lintel code Length (mm) Clip fixingsCTF5, 7 & 9 750-3600 50mm x 3.35mm diam. Plain head galvanised nailsCTF5, 7 & 9 3900-4800 38mm x No10 RD/HD sherardised wood screwsCN23 Up to 4800 38mm x No10 RD/HD sherardised wood screws
Lintel NumberLength (mm) of clipsUp to 1800 31950-3000 53300-4200 74575-4800 9
Typical application showing lintel over window
In addition to the Cavity Wall Installation Guide,please read the following for Catnic timberframe lintel installation
Technical Specifications & Quality AssurancesCatnic is committed to providing architects, designersand builders with useful information and terminologyrelevant to the specification of Catnic lintels
Specifications Where to use a separate DPC 76Quality Assurance 77Technical Information 78The Environment 79Guide to safe storage and handling 80Material Specification 81Glossary of technical terms 82
76
Dornock
Inverness
Aberdeen
DundeePerth
DunbarEdinburgh
Stirling
Alston
Ayr
Lerwick
Glasgow
NewcastleCarlisle
Workington
Stranraer
Belfast
Londonderry
Enniskillen DungannonMiddlesborough
WhitbyDarlington
Ripon
York
Hull
Grimsby
Skegness
Norwich
Hebben Bridge
Doncaster
Lincoln
Nottingham
Colwyn Bay
Skelmersdale
ChesterBangor
Bala
ManchesterSheffield
Macclesfield
Stafford
LeicesterShrewsbury
Birmingham
Hay-on-Wye Northampton Cambridge
Peterborough
Welwyn Garden CityColchesterLuton
LondonStaines
GatwickDover
EastbourneBrightonPooleSouthampton
Aldershot
NewburySwindon
Gloucester
BristolWeston-super-Mare
WatchetTaunton
Barnstaple
SidmouthExeter
Cardiff
Swansea
Brecon
Llanidloes
Llandrindod Wells
Exposure Approximate windzones driven rain
(litres/m2 per spell)
1 (sheltered) Less than 33
2 (moderate) 33 to less than 56.5
3 (severe) 56.5 to less than 100
4 (very severe) 100 or more
To satisfy NHBC and Zurich Municipal technicalrequirements, Catnic lintels only require a separate DPC in severe exposure zones i.e. zones 3 & 4 of the map and as determined by BS 8104
Where to Use a Separate DPC
NHBC Amendments Oct 1992 requirea separate damp proof protection forall lintels in Scotland, Northen Ireland,the Isle of Man and in areas of severeor very severe exposure to drivingrain, as defined under BS 5628 Part 3.The map indicates typical exposurecategories.
In such cases, a cavity tray/dampproof protection should provide animpervious barrier draining wateroutwards. It should have an overallminimum upstand of 140mm, returnedto the inner leaf masonry, and be soshaped that there is not less than100mm vertical protection above apoint where mortar could collect.
Reproduced from BRE report ThermalInsulation: avoiding risks by permission ofthe Controller of HMSO: Crown Copyright. Report available from CRC Ltd on 020 7505 6622
Where exposure conditions or localbuilding regulations demand aseparate DPC, Catnic cavity walllintels not only provide additionalprotection against the elements butalso act as a support and template forthe DPC, making it easier to install,and with less risk of damage. TheDPC should project at least 25mmbeyond the outer face of the cavitycloser and vertical DPC. It shouldprovide drip protection for the doorand window heads, and cover theends of the lintel to ensure moisture isshed clear of the reveals. For allcoastal site applications where thesoffit of the lintel is exposed, the useof a soffit cladding in conjunction witha separate DPC is highly recommendedto improve appearance and extendnormal maintenance periods.
7776
Domoch
Inverness
Aberdeen
DundeePerth
DunbarEdinburgh
Stirling
Alston
Ayr
Lerwick
Glasgow
NewcastleCarlisle
Workington
Stranraer
Belfast
Londonderry
Enniskillen DungannonMiddlesborough
WhitbyDarlington
Ripon
York
Hull
Grimsby
Skegness
Norwich
Hebben Bridge
Doncaster
Lincoln
Nottingham
Colwyn Bay
Skelmersdale
ChesterBangor
Bala
ManchesterSheffield
Macclesfield
Stafford
LeicesterShrewsbury
Birmingham
Hay-on-Wye Northampton Cambridge
Peterborough
Welwyn Garden CityColchesterLuton
LondonStaines
GatwickDover
EastbourneBrightonPooleSouthampton
Aldershot
NewburySwindon
Gloucester
BristolWeston-super-Mare
WatchetTaunton
Barnstaple
SidmouthExeter
Cardiff
Swansea
Brecon
Llanidloes
Llandrindod Wells
Exposure Approximate windzones driven rain
(litres/m2 per spell)
1 (sheltered) Less than 33
2 (moderate) 33 to less than 56.5
3 (severe) 56.5 to less than 100
4 (very severe) 100 or more
To satisfy NHBC and Zurich Municipal technicalrequirements, Catnic lintels only require a separate DPC in severe exposure zones i.e. zones 3 & 4 of the map and as determined by BS 8104
Where to Use a Separate DPC
NHBC Amendments Oct 1992 requirea separate damp proof protection forall lintels in Scotland, Northen Ireland,the Isle of Man and in areas of severeor very severe exposure to drivingrain, as defined under BS 5628 Part 3.The map indicates typical exposurecategories.
In such cases, a cavity tray/dampproof protection should provide animpervious barrier draining wateroutwards. It should have an overallminimum upstand of 140mm, returnedto the inner leaf masonry, and be soshaped that there is not less than100mm vertical protection above apoint where mortar could collect.
Reproduced from BRE report ThermalInsulation: avoiding risks by permission ofthe Controller of HMSO: Crown Copyright. Report available from CRC Ltd on 020 7505 6622
Where exposure conditions or localbuilding regulations demand aseparate DPC, Catnic cavity walllintels not only provide additionalprotection against the elements butalso act as a support and template forthe DPC, making it easier to install,and with less risk of damage. TheDPC should project at least 25mmbeyond the outer face of the cavitycloser and vertical DPC. It shouldprovide drip protection for the doorand window heads, and cover theends of the lintel to ensure moisture isshed clear of the reveals. For allcoastal site applications where thesoffit of the lintel is exposed, the useof a soffit cladding in conjunction witha separate DPC is highly recommendedto improve appearance and extendnormal maintenance periods.
Quality Assurance
BSI KitemarkThe Kitemark is a BSIcertification mark,licensed for use on aproduct afterindependent testing has been carriedout to establish conformity with thestated standard, and satisfactoryassessment of the manufacturingcontrol process has taken place toestablish that such conformity mayconsistently be achieved.
BSI verifies continuing productconformity by periodic producttesting and assessment of themanufacturing control process.
BBA CertificationThe BBA’s Agrémentcertificates have been providingauthoritative and independentinformation on the performance ofbuilding products for over 35 years.Every Agrément certificate containsimportant data on durability;installation and compliance withBuilding Regulations across the UK.
Assessment involves three distinctareas – 1) laboratory testing, 2) siteinspections, undertaken by the BBA’sown inspection Services team and 3)factory production control.
For copies of Catnic’s BBA Certificatesplease visit www.Catnic.com or call uson 029 2033 7900
Technical ConformityCatnic comply with the technicalrequirement of:
• National House-Building Council(NHBC):is the independentregulatory boardand the worlds’leading warranty and insuranceprovider for new homes in the UK.
• Housing Association PropertyMutual (HAPM):with appropriateadjustmentfactors lintels are rated by HAPM assatisfying the ‘35 years to firstmaintenance’ durability rating, laiddown in the ‘HAPM Component LifeManual’.
• Local Authority Building Control(LABC): is dedicated tomaintaining thehighest standard inbuilding design andconstruction. LABC is a publiclyaccountable, independent buildingcontrol provider.
Management System RegistrationIn today’s increasingly competitiveenvironment customers are becomingmore sophisticated and betterinformed. Expectations are growingand businesses need to demonstratecommitment to quality.
As an accredited organisation, we are committed to making continuousperformance improvements in keyareas, such as business efficiencyand risk management, reviewingprocedures and levels of service.
Catnic is a BSI registered firm withquality management system inaccordance with BS EN ISO9001:2000 which provides a set ofprocesses that ensure:
• Clarification and documentation ofpolicies and objectives
• Relating to customers’ requirementsto production with a view toachieving customer satisfaction
• Understanding how statutory andregulatory requirements impact on Catnic and our customers
• Clear responsibilities andauthorities – increasing motivationand commitment
• Reduce waste
• Consistency and traceability ofproducts and services
• High level of internal and externalcommunications
British and European Standards: Catnic’sstandard range lintels are designed andmade to very high quality standards
The products are:• Manufactured from pre-galvanised
steel in accordance with BS EN 10327:2004 of grade DX51Dwith or without polyester coatedfinish.
• Lintels conform to the materialspecifications laid down in BS 5977: Part 2:1983 and BS EN 845-2:2003
• Catnic was the first lintelmanufacturer to be awarded a BSI Kitemark licence and BBA certificate.
CE
RT
IFIE
D
TO BRITISH STAN
DA
RD
BS 5977LICENCE No. KM07234
Certificate No. 91/2638
Catnic’s excellence in quality standardsis internationally recognised
EN ISO 9001: 2000Certificate No. FM14913
78
Technical Information
Structural performanceThe structural data published in theloading tables included in this technicalguide, was achieved in accordance withthe requirements of BS 5977: Part2:1983 and BS EN 845-2.2003.Extensive testing was undertaken at thefollowing test houses:
• The University of Wales, School of Engineering
• The University of Glamorgan,Construction Centre
• Ceram Building Technology, Stoke-on-Trent
Safe working loads (SWL)*, as defined byBS 5977: Part 2:1983 for cavity walllintels refer to uniform distributed loadsapplied in the inner to outer leaf ratios:
• 1:1 For lintels supporting masonryonly
• 3:1 For lintels normally carrying timberfloors
• 5:1 For lintels normally carryingconcrete floors
The CH & CX lintel range refers touniformly distributed loads in the ratio of19:1 when non standard or unusualloading conditions occur.
A lintel should not exceed a maximumvertical deflection of 0.003 x the effectivespan (effective span = distance betweencentre of bearings) when subjected to thesafe working load (SWL).
*The brochure SWL’s are based on thelesser value derived from a serviceabilitydeflection limitation of
Fire testsCatnic lintels have been independentlytested in accordance with the relevantparts of BS476, Methods of Determinationof the Fire Resistance of LoadbearingElements of Construction. Details of thetest results can be found in TRADA(Timber Research and DevelopmentAssociation) Nos. FR254, 275, 659, 863,1662 and RF94015 and FROSI (FireResearch Organisation) No. 5001.
Thermal performanceAll Catnic cavity wall lintels contribute tothe thermal integrity of the building asthey are supplied with an insulated core.The core of the ‘Cougar Open Back’ stylelintels is fully filled with CFC & HCFC freeinsulation to prevent cold voids.
Also, because Catnic cavity wall lintelsare shaped to form a built-in damp proofcourse, partial fill cavity wall insulationcan extend down to the top of the lintel.
This means that the cold voids normallyassociated with separate damp proofcourses are avoided, without the needto install specially shaped insulationbatts behind the DPC.
To achieve the thermal benefits of a Cougar open back or Classiccombined box lintel in accordance withthe ‘robust details’ as referred in theapproved documents: Part L1 and PartL2, the window frame should bepositioned so that the back face of theframe overlaps the inner face of theouter leaf of the cavity wall by aminimum of 30mm.
The standard range of cavity wall lintelsincorporating perforated base plates have been designed tominimise any potential cold bridge pathwithout compromising its structuralintegrity. The unique slotted base platedesign on the underside of the lintelsprovides an effective conductivity notexceeding 30W/mK which satisfies therequirements of the approved documentto support Part L1 & L2 2002 edition.
The Research, Development and Technologybusiness of Corus combines top class innovationand cutting edge technology to deliver ‘metalssolutions’ in a constantly changing world
We use up to the minute technology to expand and improvethe quality of our performance; we continually invest in andupgrade our manufacturing processes and use the latestmethods in process analysis and design
effective span
325[ ] ultimate failure
1.6 (min)[ ]or
SustainabilityCatnic, part of the Corus group ofcompanies, utilises steel from ourEuropean manufacturing operations thathave achieved certification toEnvironmental Management StandardISO14001.
Corus places great emphasis on thecontribution we make to a sustainablesociety and is committed toincorporating the principles ofsustainable development into allaspects of our operations.
Steel itself is 100% recyclable and canbe recycled again and again, withoutdegradation of its properties orperformance. Steel’s excellentmechanical properties, combined withits high strength, contribute to improvedsafety performance. The steel in usetoday will be reused and recycled manytimes in the future. More than 40% ofthe world’s production of ‘new’ steel isin fact made from recycled steel withoutany loss of quality. The current recyclingrate and reuse rate for steelconstruction products in the UK is 94%.
Our products are durable, adaptable,reusable and recyclable. They are
essential to modern life – for examplethey are used in affordable and energy-efficient modern housing. Through ourresearch and development activities, weare continuing to develop products thatgive additional social and environmentalbenefits to our customers and societyas a whole.
Copies of the Corus CorporateResponsibility Report 2007/8 areavailable on request or can bedownloaded at www.catnic.com
Global Warming Potential (GWP)The expanded polystyrene (EPS)incorporated into our pre-insulatedlintels does not use, contain or produceformaldehyde, CFC’s or indeed any socalled soft CFC’s (i.e. HCFC’s andHFA’s).
The product conforms to the MontrealProtocol and has an ozone potential of zero.
The material content and manufactureof EPS has no major negative impacton the environment
The manufacturer of our insulationproduct have quoted a GWP < 5 for thefinished product.
Health & Safety PolicyCatnic actively work towards Corus’own international safety rating systemand have one of the highest scoresamongst all Corus manufacturing sitesin the UK.
• We believe that all our activities canbe undertaken safely and we willnever compromise safety.
• We will conduct our business in a waythat ensures the health and well beingof our employees, contractors and anyperson affected by our activities.
• We know that continuousimprovement of our health and safetyperformance is essential for asuccesful company.
• Everyone in Corus has responsibilityfor their own and others' health andsafety.
• We will encourage a health and safetyculture in Corus.
Copies of the Catnic EnvironmentalPolicy are available on request or canbe downloaded at www.catnic.com
Environmental PolicyCatnic are committed to protecting the environment by minimising the impact of ouroperations and our products through the adoption of sustainable practices and throughcontinuous improvement in environmental performance and control. We believe that respectfor the environment is critical to the success of our business and our aim, therefore, is tocontinuously improve our performance
We consider care for the environment to be essentialboth in terms of our duty to society and to ensure thecontinuity of our business
The Environment
79
SustainabilityCatnic, part of the Corus group ofcompanies, utilises steel from ourEuropean manufacturing operations thathave achieved certification toEnvironmental Management StandardISO14001.
Corus places great emphasis on thecontribution we make to a sustainablesociety and is committed toincorporating the principles ofsustainable development into allaspects of our operations.
Steel itself is 100% recyclable and canbe recycled again and again, withoutdegradation of its properties orperformance. Steel’s excellentmechanical properties, combined withits high strength, contribute to improvedsafety performance. The steel in usetoday will be reused and recycled manytimes in the future. More than 40% ofthe world’s production of ‘new’ steel isin fact made from recycled steel withoutany loss of quality. The current recyclingrate and reuse rate for steelconstruction products in the UK is 94%.
Our products are durable, adaptable,reusable and recyclable. They are
essential to modern life – for examplethey are used in affordable and energy-efficient modern housing. Through ourresearch and development activities, weare continuing to develop products thatgive additional social and environmentalbenefits to our customers and societyas a whole.
Copies of the Corus CorporateResponsibility Report 2007/8 areavailable on request or can bedownloaded at www.catnic.com
Global Warming Potential (GWP)The expanded polystyrene (EPS)incorporated into our pre-insulatedlintels does not use, contain or produceformaldehyde, CFC’s or indeed any socalled soft CFC’s (i.e. HCFC’s andHFA’s).
The manufacturer of our insulationproduct have quoted a GWP < 5 for thefinished product.
Ozone Depletion Potential (ODP)The product conforms to the MontrealProtocol and has an ozone depletionpotential of zero. The material contentand manufacture of EPS has no majornegative impact on the environment.
Health & Safety PolicyCatnic actively work towards Corus’own international safety rating systemand have one of the highest scoresamongst all Corus manufacturing sitesin the UK.
• We believe that all our activities canbe undertaken safely and we willnever compromise safety.
• We will conduct our business in a waythat ensures the health and well beingof our employees, contractors and anyperson affected by our activities.
• We know that continuousimprovement of our health and safetyperformance is essential for asuccesful company.
• Everyone in Corus has responsibilityfor their own and others' health andsafety.
• We will encourage a health and safetyculture in Corus.
Copies of the Catnic EnvironmentalPolicy are available on request or canbe downloaded at www.catnic.com
Environmental PolicyCatnic are committed to protecting the environment by minimising the impact of ouroperations and our products through the adoption of sustainable practices and throughcontinuous improvement in environmental performance and control. We believe that respectfor the environment is critical to the success of our business and our aim, therefore, is tocontinuously improve our performance
We consider care for the environment to be essentialboth in terms of our duty to society and to ensure thecontinuity of our business
The Environment
79
08 Catnic Brochure JAN 09:Layout 1 29/01/2009 10:58 Page 79
8180
Material SpecificationGuide to safe storage and handling
‘Cougar Open Back’ StylesCG rangeThe lintels are manufactured fromgalvanised steel to BS EN10327: 2004(continuously hot-dip coated strip andsheet of low carbon steels and coldforming - technical deliveryconditions) of grade DX51D & Z275,but with a minimum yield stress of250N/mm2. The lintels are furtherprotected against corrosion by a blackcoloured polyester resin coatingapplied to all external surfaces. Thelintels are fully insulated withexpanded polystyrene bead of density18kg/m3 giving a thermal conductivityof between 0.031W/mK and0.036W/mK.
CH & CX rangeThe lintels are manufactured fromgalvanised steel to BS EN10327: 2004of grade DX51D & Z275 with aminimum yield stress of 250N/mm2.The lintels are further protectedagainst corrosion by a black colouredpolyester resin coating applied to allexternal surfaces of the lintels.
The lintels are fully insulated withexpanded polystyrene boardmanufactured in accordance with BS 3837: Part 1: 2004 (Expandedpolystyrene boards specification forboards manufactured fromexpandable beads). The material isCFC & HCFC free and has an ozonedepletion potential (ODP) of zero.
To satisfy the corrosion protectionsystem of BS 5977: Part 2 and NHBCtechnical requirements, lintelsgalvanised to BSEN ISO1461: 1999must be installed with a separatedamp proof course.
External Solid Wall/ Internaland Timber Frame StylesCN and CTF rangeThe lintels are manufactured fromgalvanised steel to BS EN 10327:2004 (continuously hot-dip coatedstrip and sheet of low carbon steelsand cold forming - technical deliveryconditions) of grade DX51D & Z275but with a minimum yield stress of250N/mm2. The lintels (excludinginternal lintels CN92 and CN102) arefurther protected against corrosion bya polyester resin coating applied to all external surfaces of the lintel. Thelintels are insulated (where applicable)with expanded polystyrene board to BS 3837 Part 1: 2004 (expandedpolystyrene boards – specification forboards manufactured fromexpandable beads).
CXL rangeThe lintels are manufactured from auniversal beam section and 6.0mmstructural grade steel plate GradeS275 to BS EN 10025-2:2004 andhot-dip galvanised after manufactureto BS EN ISO1461:1999.
CNZ rangeThe lintels are manufactured fromgalvanised steel to BS EN 10326:2004 (continuously hot-dip coatedstrip and sheet of structural steels -technical delivery conditions) of gradeS250GD & Z600. All external lintel cutedges are treated with a corrosionresistant paint.
Stainless Steel rangeThe lintels are manufactured fromAustenitic Stainless Steel, grade304s15 to BS EN 10088-2-1.4301.
Feature Lintels
CCA and CCB rangeThe lintels are manufactured from3.0mm structural grade steel plate ofgrade S275 to BS EN10025-2:2004and hot-dip galvanised aftermanufacture to BS EN ISO1461:1999.
Storage• All products should be stored in a
clean and dry environment on a firmeven surface, clear of the ground.
• Single lintels should be stored onpallets or suitable racking andprevented from being accidentallydislodged.
• Remove all metal strapping with careand discard safely and responsibly.
Handing• Gloves should be worn to avoid injury
from any sharp edges.
• When lifting or carrying a lintel, undertake a personal risk assessmentpaying attention to the size andweight details found on the productlabel.
• Processes such as welding, burning,cutting or grinding can result invaporising the metal or generatingairborne particles that may presentadditional hazards.
Application• Do not use damaged goods.
• Refer to Installation Guides detailedon page 70.
Disposal• When disposing of any Catnic
products or packaging, dueconsideration must be given to theenvironmental impact of the methodof disposal.
Control of Substances Hazardous to Health Regulations 1994 (COSHH)
• All products are considered non-hazardous to health under normalconditions of use.
• Copies of COSHH sheets areavailable on request
All products should be used inaccordance with their specificinstructions to prevent failure
81
Material Specification
‘Cougar Open Back’ StylesCG rangeThe lintels are manufactured fromgalvanised steel to BS EN10327: 2004(continuously hot-dip coated strip andsheet of low carbon steels and coldforming - technical deliveryconditions) of grade DX51D & Z275,but with a minimum yield stress of250N/mm2. The lintels are furtherprotected against corrosion by a blackcoloured polyester resin coatingapplied to all external surfaces. Thelintels are fully insulated withexpanded polystyrene bead of density18kg/m3 giving a thermal conductivityof between 0.031W/mK and0.036W/mK.
CH & CX rangeThe lintels are manufactured fromgalvanised steel to BS EN10327: 2004of grade DX51D & Z275 with aminimum yield stress of 250N/mm2.The lintels are further protectedagainst corrosion by a black colouredpolyester resin coating applied to allexternal surfaces of the lintels.
The lintels are fully insulated withexpanded polystyrene boardmanufactured in accordance with BS 3837: Part 1: 2004 (Expandedpolystyrene boards specification forboards manufactured fromexpandable beads). The material isCFC & HCFC free and has an ozonedepletion potential (ODP) of zero.
External Solid Wall/ Internaland Timber Frame StylesCN and CTF rangeThe lintels are manufactured fromgalvanised steel to BS EN 10327:2004 (continuously hot-dip coatedstrip and sheet of low carbon steelsand cold forming - technical deliveryconditions) of grade DX51D & Z275but with a minimum yield stress of250N/mm2. The lintels (excludinginternal lintels CN92 and CN102) arefurther protected against corrosion bya polyester resin coating applied to all external surfaces of the lintel. Thelintels are insulated (where applicable)with expanded polystyrene board to BS 3837 Part 1: 2004 (expandedpolystyrene boards – specification forboards manufactured fromexpandable beads).
CXL rangeThe lintels are manufactured from auniversal beam section and 6.0mmstructural grade steel plate GradeS275 to BS EN 10025-2:2004 andhot-dip galvanised after manufactureto BS EN ISO1461:1999.
CNZ rangeThe lintels are manufactured fromgalvanised steel to BS EN 10326:2004 (continuously hot-dip coatedstrip and sheet of structural steels -technical delivery conditions) of gradeS250GD & Z600. All external lintel cutedges are treated with a corrosionresistant paint.
(Excludes CNZ97D which is furtherprotected against corrosion by apolyester resin coating applied to all external surfaces of the lintel).
Stainless Steel Lintels
The lintels are manufactured fromAustenitic Stainless Steel, grade304s15 to BS EN 10088-2-1.4301.
Feature Lintels
CCA and CCB rangeThe lintels are manufactured from3.0mm structural grade steel plate ofgrade S275 to BS EN10025-2:2004and hot-dip galvanised aftermanufacture to BS EN ISO1461:1999.
08 Catnic Brochure JAN 09:Layout 1 29/01/2009 10:58 Page 81
Special Internals Meter Boxes Replace Steelwork
8382
Glossary of technical terms
LintelA structural member spanning anopening in a wall.
Clear span or Clear openingThe clear distance between lintel supports.
Safe working load (SWL)The total uniformly distributed load(UDL) that the lintel is designed tosupport, whilst providing an appropriatesafety factor.
Triangulated masonry loadA load assessed in accordance with theguidelines of BS 5977 Part 1:1981 andAMD 4796:1985
Uniformly Distributed Load (UDL)A load that is uniformly spread along theentire length of the lintel.
Point loadThe load applied from a single membersuch as a steel beam or girder truss. Itshould be spread over an appropriatearea so that the limiting design valuesare not exceeded.
Moment of inertia (Ixx)Represents the moment of inertia orsecond moment of area of the lintelsection about a horizontal axis throughthe lintel centroid indicating the stiffnessof a lintel under a given load andindicative of the lintel shape. The greaterthe Ixx level, the stiffer the lintel will beand hence the less a lintel will deflect.
Deflection (δ)Vertical/horizontal displacement of thelintel due to bending about thevertical/horizontal axis.
Modulus of elasticity (Zxx min)The section Modulus of the lintel abouta horizontal axis, when multiplied by thepermissible working stress, the resultantvalue is the serviceability moment.
Serviceability reactionThe permissible load at an end supportwithin the working load capacity of thelintel webs.
End bearingThe bearing length at lintel supports.
Site
Address
Post Code Tel
Email Fax
Lintel Requirements*
Catnic Technical Enquiry Request Form
Is a separate damp proof course to be installed? Yes No
Special Requirements (eg. send to Site/Merchant etc.)
Please include the following (please tick)
NOTE: IT IS IMPORTANT FOR A QUICK TURNAROUND THAT ALL BOXESARE COMPLETED CORRECTLY BY REFERRING TO THE DRAWINGSBEFORE SENDING TO OUR TECHNICAL SERVICES DEPARTMENT
Please indicate any fairfaced internal areas on drawings
Catnic endeavor to return enquiries at the soonest opportunity. If your enquiry is urgent please contact TechnicalServices on 029 2033 7900.
Please ensure that the essential information (indicated in red) is provided, to enable a quick turnaround.
Please return on Fax: 087 0024 1809
Customer
Address*
Post Code* Tel*
Email* Fax
Customer
Name*
Date
Please indicate whether outer leaf support is required at eaves level Yes No
* Mandatory Fields
Wall Construction (please fill in dimensions)
OUTER CAVITY INNER
Type Width Width Between Type Width(mm) Masonry inc. insulation (mm)
Brick Brick
Stone Dense block
Dense block Lightweight block
Lightweight block Medium block
Medium block Timber frame
Steel frame
Plans/dimensions Elevations (all)
Sections (all) Site plan (for summary)
EITHER Suspended floor carcass timber Roof carcass (for girder trusses)
OR Suspended concrete floor span directions Structural engineers steelwork arrangements
Attic truss carcassing
Technical Services
029 2033 7900Fax this enquiry to
087 0024 1809
Special Internals Meter Boxes Replace Steelwork
8382
Glossary of technical terms
LintelA structural member spanning anopening in a wall.
Clear span or Clear openingThe clear distance between lintel supports.
Safe working load (SWL)The total uniformly distributed load(UDL) that the lintel is designed tosupport, whilst providing an appropriatesafety factor.
Triangulated masonry loadA load assessed in accordance with theguidelines of BS 5977 Part 1:1981 andAMD 4796:1985
Uniformly Distributed Load (UDL)A load that is uniformly spread along theentire length of the lintel.
Point loadThe load applied from a single membersuch as a steel beam or girder truss. Itshould be spread over an appropriatearea so that the limiting design valuesare not exceeded.
Moment of inertia (Ixx)Represents the moment of inertia orsecond moment of area of the lintelsection about a horizontal axis throughthe lintel centroid indicating the stiffnessof a lintel under a given load andindicative of the lintel shape. The greaterthe Ixx level, the stiffer the lintel will beand hence the less a lintel will deflect.
Deflection (δ)Vertical/horizontal displacement of thelintel due to bending about thevertical/horizontal axis.
Modulus of elasticity (Zxx min)The section Modulus of the lintel abouta horizontal axis, when multiplied by thepermissible working stress, the resultantvalue is the serviceability moment.
Serviceability reactionThe permissible load at an end supportwithin the working load capacity of thelintel webs.
End bearingThe bearing length at lintel supports.
Site
Address
Post Code Tel
Email Fax
Lintel Requirements*
Catnic Technical Enquiry Request Form
Is a separate damp proof course to be installed? Yes No
Special Requirements (eg. send to Site/Merchant etc.)
Please include the following (please tick)
NOTE: IT IS IMPORTANT FOR A QUICK TURNAROUND THAT ALL BOXESARE COMPLETED CORRECTLY BY REFERRING TO THE DRAWINGSBEFORE SENDING TO OUR TECHNICAL SERVICES DEPARTMENT
Please indicate any fairfaced internal areas on drawings
Catnic endeavor to return enquiries at the soonest opportunity. If your enquiry is urgent please contact TechnicalServices on 029 2033 7900.
Please ensure that the essential information (indicated in red) is provided, to enable a quick turnaround.
Please return on Fax: 087 0024 1809
Customer
Address*
Post Code* Tel*
Email* Fax
Customer
Name*
Date
Please indicate whether outer leaf support is required at eaves level Yes No
* Mandatory Fields
Wall Construction (please fill in dimensions)
OUTER CAVITY INNER
Type Width Width Between Type Width(mm) Masonry inc. insulation (mm)
Brick Brick
Stone Dense block
Dense block Lightweight block
Lightweight block Medium block
Medium block Timber frame
Steel frame
Plans/dimensions Elevations (all)
Sections (all) Site plan (for summary)
EITHER Suspended floor carcass timber Roof carcass (for girder trusses)
OR Suspended concrete floor span directions Structural engineers steelwork arrangements
Attic truss carcassing
Technical Services
029 2033 7900Fax this enquiry to
087 0024 1809
84
Notes
85
For more information aboutthese products, please callCatnic on 029 2033 7900 for a brochure
LintelsPioneers of the steel lintel for morethan three generations with areputation for superior quality,reliability and backed by excellencein service.
Steel LintelsSpecial LintelsStainless Steel Lintels Free design service for bespoke feature lintelsFree scheduling service
SteelworkA selection of steelwork beams,columns and channels for whenloading conditions exceed ourstandard range of lintels
Universal beams Universal columnsParallel flange channels
Steel Plasterer’s BeadsPrecision engineered and simple touse to create, edges, corners andjoints that are resistant to chipping,cracking and impact damage.
Galvanised steel plaster and render beadsStainless steel plaster and render beads
PVC-U Plasterer’s Beads Light, rigid, non-corrosive, andeasy to use material, that offers a cost-effective way to create,edges, corners and joints that are resistant to chipping, cracking and impact damage.
Plaster and render beads
Expanded MetalEasy to use, versatile and perfectlyformed expanded metal productsbenefit from our long experience ofusing steel in construction.
Metal LathCoil MeshArch formers
Wall Starter KitsSTRONGHOLD Wall Starter Kitsare a simple yet effective systemfor tying new masonry walls toexisting walls.
Stainless steel wall starter kitsoffering superb corrosionresistance.PVC Coated wall starter kitsgalvanized steel for durablecorrosion resistance.
Cavity Wall TiesHigh quality stainless steel wall tiesfor ease of use and a long life.
Ties for brick to blockconstructionTies for brick to timberconstruction
QwikpostErecting a new boundary or repairing a gale-damaged fencehas never been easier with the Catnic's durable andaffordable fence support systems.
Garden fence post spikesRepair spikesBolt-down supportsConcrete-in postsPost extendersArris brackets, U-clips and Z- clips
- much more than just Lintels...
87
Lintel Product Selector
Catnic
December 2008
December 2008
Cl/Sfb
UniclassL325:P4142
EPICF631:X442
(31.9) Hh2
87 87
Catnic is a Corus Group company. Furtherinformation can be found on the Corus website atwww.corusgroup.com
Care has been taken to ensure that this informationis accurate, but Corus Group plc, and itssubsidiaries, does not accept responsibility orliability for errors or information which is found tobe misleading.
This publication was printed by a Corus approvedsupplier that complies with ISO 9001, ISO 14001and OHSAS 18001 accreditation. Paper used isRegency Satin, which is manufactured from ECF(Elemental Chlorine Free) pulp sourced fromcertified or well managed forests and plantations,inks used are vegetable based.
Copyright 2008 Corus
www.catnic.com
CatnicPontypandy Industrial EstateCaerphillyCF83 3GLTelephone 029 2033 7900Facsimile 029 2086 7796
C03:30000:UK:11/2008
PDA8753/05
Photographs are supplied courtesy of Andersen Windows/Black Millwork,Barrington Homes, Taylor Wimpy PLC, Williams Lester Architects