lighting technology - deutsche messe agdonar.messe.de/exhibitor/hannovermesse/2017/u223864/...192...
TRANSCRIPT
General Catalogue 01.08.2009 http:// www.waromgroup.com
2
�
�
�
�
�
�
BAD71-�� Series Explosion-proof Light
Fittings
BAD71-250
BAD71-400
Available lamp wattage (W)
SME
160, 250
500(450)
A
200, 300
500
� Ordering note
2/52
Type/Ordering code
�=Catalogue number logic
�=Selection table
Lighting Technology
=BAD71 - �=�
SME: Self ballast mercury lamp
A: Incandescent lamp
Lamp wattage(W)
Lamp
Explosion-proof light fittings
Zones 1C2X 21C22
Explosion protection to
-CENELEC
-IEC
Can be used
in Zone 1 and Zone 2
in Zone 21 and Zone 22
Available light source (not more than 500W)
- Self ballast mercury lamp
- Incandescent lamp
Independent connection compartment, side open for
connection, convenient to install and maintain.
Enclosure has two versions: 250 and 400.
Possible to supply external reflector, enlarging the luminous
intensity.
1.Specify all data at request of “catalogue number logic”,
2.If accessories are required, please purchase as the “Accessories table” or at guide of “ordering code”.
3.The light fittings are supplied without external reflector, if required, please purchase as “ordering code” in “Accessories table”.
General Catalogue 01.08.2009 http:// www.waromgroup.com
2Pendant Light Fittings
BAD71 Series Explosion-proof Light Fittings
2/53
===II 2G Exde II CT3
Ex tD A21 IP65 T200�
LCIE 08 ATEX 6105, IECEX CQM 08.0018
PCEC (China)
EN 60079-0:2004; EN 60079-1:2004; EN 60079-7:2003;
IEC 60079-0:2004; IEC 60079-1:2003; IEC 60079-7:2001
IEC 61241-0:2004 ; IEC 61241-1:2004
Copper-free aluminium, powder coated, yellow
Toughened glass, stands 4J impact
High purity aluminium
Pure aluminium, anodicoxidation treatment for surface
Stainless steel
Stainless steel
AC 220V�240V 50Hz
M5(earthing bolt inside and outside of the light fittings)
IP65
-20��+55�
Terminal 3 x 1.5�2.5mm2 (L+N+PE)
2 x M25 x 1.5=mäìÖ
Exe Cable gland DQM-I, manufactured by Warom, please see P7/17�18.
The light fittings are supplied without lamp.
9.30kg
BAD71-250
Mounting versions
Lamp wattage
160W/250W
200W/300W
Lamp holder
E27/E40
E27/E40
Available lamp
SME
A
ceiling
mounting
wall mounting 30�
wall mounting 90�
Technical data
Explosion-proof light fittings
Explosion protection Gas explosion protection
Dust explosion protection
Certificates For gas explosion protection
For dust explosion protection
Conformity to standards
Material Enclosure
Transparent cover
Reflector(internal)
Reflector(external)
Wire guard
Exposed fastener
Lamp
Rated voltageEarthing protectionDegree of protectionAmbient temperatureConnecting terminalCable entriesCable gland(option)RemarksWeight
General Catalogue 01.08.2009 http:// www.waromgroup.com
2
Angle
0
5
10
15
20
25
30
35
40
45
50
55
CP
1117
1109
1070
980
875
763
666
587
506
443
401
364
Angle
60
65
70
75
80
85
90
95
100
105
110
115
CP
337
306
251
192
131
77
37
13
5
4
2
1
Angle
120
125
130
135
140
145
150
155
160
165
170
175
180
CP
1
0
1
1
1
1
1
1
1
1
1
1
1
Pendant Light Fittings
BAD71 Series Explosion-proof Light Fittings
2/54
160W Self ballast mercury lamp*0.64200W Incandescent lamp*0.41300W Incandescent lamp*0.83
Photometric data of 250W self
ballast mercury lamp
Rated luminous flux:4900lm;
The data from PHILIPS lamp;
Luminous intensity distribution cd/1000lm
Photometric data of 250W self ballast
mercury lamp(with spherical reflector)
Rated luminous flux:4900lm;
The data from PHILIPS lamp;
Luminous intensity distribution cd/1000lm
Photometric data of 250W self ballast
mercury lamp(with bevel reflector)
Rated luminous flux:4900lm;
The data from PHILIPS lamp;
Luminous intensity distribution cd/1000lm
mÜçíçãÉíêáÅ=Ç~í~=(BAD71-250)
160W Self ballast mercury lamp*0.64200W Incandescent lamp*0.41300W Incandescent lamp*0.83
160W Self ballast mercury lamp*0.64200W Incandescent lamp*0.41300W Incandescent lamp*0.83
Angle
0
5
10
15
20
25
30
35
40
45
50
55
CP
315
314
309
304
299
300
303
298
293
296
303
310
Angle
60
65
70
75
80
85
90
95
100
105
110
115
CP
317
317
313
306
291
270
243
213
180
143
107
73
Angle
120
125
130
135
140
145
150
155
160
165
170
175
180
CP
45
45
23
9
4
3
2
1
0
0
0
0
0
0�Reflection angle CP
0
5
15
25
35
45
55
65
75
85
90
829
730
615
509
467
387
267
129
34
11
6
95
105
115
125
135
145
155
165
175
180
2
2
2
2
2
2
2
2
2
2
0
5
15
25
35
45
55
65
75
85
90
829
800
707
573
460
337
169
50
6
2
1
95
105
115
125
135
145
155
165
175
180
1
1
1
1
1
1
1
1
1
1
90�Reflection angle CP
We can provide lighting designs and lighting data by using professional lighting calculation software DIALUX of Germany upon
stimulated situation and working conditions at user’s request.
General Catalogue 01.08.2009 http:// www.waromgroup.com
2
2/55
Mounting versions
===II 2G Exde II CT3
Ex tD A21 IP65 T200�
LCIE 08 ATEX 6111
PCEC (China)
EN 60079-0:2004; EN 60079-1:2004; EN 60079-7:2003;
IEC 60079-0:2004; IEC 60079-1:2003; IEC 60079-7:2001
IEC 61241-0:2004; IEC 61241-1:2004
Copper-free aluminium, powder coated, yellow
Toughened glass, stands 4J impact
High purity aluminium
Pure aluminium, anodicoxidation treatment for surface
Stainless steel
Stainless steel
AC 220V�240V 50Hz
M5(earthing bolt inside and outside of the light fittings)
IP65
-20��+55�
Terminal 3 x 1.5�2.5mm2 (L+N+PE)
2 x M25 x 1.5 Plug
Exe Cable gland DQM-I, manufactured by Warom, please see P7/17�18.
The light fittings are supplied without lamp.
14.80kg
BAD71-400
Pendant Light Fittings
BAD71 Series Explosion-proof Light Fittings
Lamp wattage
500(450)W
500W
Lamp holder
E40
E40
Available lamp
SME
A
ceiling
mounting
wall mounting=30�
wall mounting 90�
Technical data
Explosion-proof light fittings
Explosion protection Gas explosion protection
Dust explosion protection
Certificates For gas explosion protection
For dust explosion protection
Conformity to standards
Material Enclosure
Transparent cover
Reflector(internal)
Reflector(external)
Wire guard
Exposed fastener
Lamp
Rated voltageEarthing protectionDegree of protectionAmbient temperatureConnecting terminalCable entriesCable gland(option)RemarksWeight
General Catalogue 01.08.2009 http:// www.waromgroup.com
2
2/56
500W Incandescent lamp*0.57
Photometric data of 500W self
ballast mercury lamp
Rated luminous flux:13000lm;
The data from PHILIPS lamp;
Luminous intensity distribution cd/1000lm
Photometric data of 500W self ballast
mercury lamp(with bevel reflector)
Rated luminous flux:13000lm;
The data from PHILIPS lamp;
Luminous intensity distribution cd/1000lm
Photometric data of 500W self ballast
mercury lamp(with spherical reflector)
Rated luminous flux:13000lm;
The data from PHILIPS lamp;
Luminous intensity distribution cd/1000lm
Photometric data (BAD71-400)
500W Incandescent lamp*0.57 500W Incandescent lamp*0.57
Angle
0
5
10
15
20
25
30
35
40
45
50
55
CP
451
453
481
488
494
488
492
514
548
578
617
666
Angle
60
65
70
75
80
85
90
95
100
105
110
115
CP
718
765
805
836
862
882
896
904
907
891
857
803
Angle
120
125
130
135
140
145
150
155
160
165
170
175
180
CP
731
649
533
402
179
178
94
37
18
12
6
2
2
Angle
0
5
10
15
20
25
30
35
40
45
50
55
CP
1979
1903
1918
1815
1619
1450
1386
1272
1191
1107
1045
998
Angle
60
65
70
75
80
85
90
95
100
105
110
115
CP
956
878
768
626
493
327
180
87
38
16
9
5
Angle
120
125
130
135
140
145
150
155
160
165
170
175
180
CP
3
2
2
2
2
2
3
3
3
3
3
3
3
0�Reflection angle CP
0
5
15
25
35
45
55
65
75
85
90
2064
2025
1719
1371
1066
887
765
537
219
62
26
95
105
115
125
135
145
155
165
175
180
12
3
2
2
3
3
3
3
3
3
0
5
15
25
35
45
55
65
75
85
90
2064
2179
1919
1609
1337
1148
1012
827
534
195
93
95
105
115
125
135
145
155
165
175
180
39
10
3
2
2
2
3
3
3
3
90�Reflection angle CP
Pendant Light Fittings
BAD71 Series Explosion-proof Light Fittings
We can provide lighting designs and lighting data by using professional lighting calculation software DIALUX of Germany upon
stimulated situation and working conditions at user’s request.
General Catalogue 01.08.2009 http:// www.waromgroup.com
2
2/57
Accessories table
Picture Accessories fittings Ordering code
250 Wire guard
400 Wire guard
250 Glass cover
400 Glass cover
250 Spherical reflector
400 Spherical reflector
250 Bevel reflector
400 Bevel reflector
271001
271002
271003
271004
271005
271006
271007
271008
Weight (kg)
0.65
0.87
2.65
4.80
0.37
0.52
0.35
0.49
Pendant Light Fittings
BAD71 Series Explosion-proof Light Fittings
General Catalogue 01.08.2009 http:// www.waromgroup.com
2
�
�
�
�
�
BAD91-�� Series Explosion-proof Light
Fittings
�=Selection table
�=Ordering note
2/58
�=Catalogue number logic
Lighting Technology
=BAD91 - �=�
Lamp wattage(W)
Lamp
Explosion-proof light fittings
HIE: Metal halide lampHSE: High pressure sodium lampHME: High pressure mercury lamp
BAD91-250
BAD91-400
HIE
175, 250
400
HME
175, 250
400
Type/Ordering codeAvailable lamp wattage (W)
HSE
150, 250
400
Zones 1C2X 21C22
1.Specify all data at request of “catalogue number logic”.
2.If accessories are required, please purchase as the “Accessories table” or at guide of “ordering code”.
3.The light fittings are supplied without lamp, if required, PHILIPS lamps are recommended. If metal halide lamp required, HPI
European standard ballast will be supplied, please use HPI European standard lamp.
4.Possible to supply power compensation capacitor, power factor cosø � 0.85. If required, please specify.
5.The light fittings are supplied without external reflector, if required, please purchase as “ordering code” in “Accessories table”.
Explosion protection to
-CENELEC
-IEC
Can be used
in Zone 1 and Zone 2
in Zone 21 and Zone 22
Integral structure with the lamp, the ballast; Independent
connection compartment, side open for connection,conve-
nient to install and maintain.
Enclosure has two versions: 250 and 400.
Possible to supply external reflector, enlarging the luminous
intensity.
General Catalogue 01.08.2009 http:// www.waromgroup.com
2Pendant Light Fittings
BAD91 Series Explosion-proof Light Fittings
2/59
===II 2G Exde II CT3
Ex tD A21 IP65 T200�
LCIE 08 ATEX 6106, IECEX CQM 08.0019
PCEC (China)
EN 60079-0:2004; EN 60079-1:2004; EN 60079-7:2003;
IEC 60079-0:2004; IEC 60079-1:2003; IEC 60079-7:2001
IEC 61241-0:2004 ; IEC 61241-1:2004
Copper-free aluminium, powder coated, yellow
Toughened glass, stands 4J impact
High purity aluminium
Pure aluminium, anodicoxidation treatment for surface
Stainless steel
Stainless steel
E40
High pressure sodium lamp (HSE): 150W, 250W
High pressure mercury lamp (HME): 175W, 250W
Metal halide lamp (HIE): 175W, 250W
Note: HPI European standard lamp ballast is available in general
AC 220V�240V 50Hz
M5(earthing bolt inside and outside of the light fittings))
IP65
-20��+55�
Terminal 3 x 1.5�2.5mm2 (L+N+PE)
2 x M25 x 1.5 Plug
Exe Cable gland DQM-I, manufactured by Warom, please see P7/17�18.
The light fittings are supplied without lamp.
13.80kg
BAD91-250
Mounting versions
ceiling
mounting
wall mounting 30�
wall mounting 90�
Technical data
Explosion-proof light fittingsExplosion protection Gas explosion protection
Dust explosion protection
Certificates For gas explosion protection
For dust explosion protection
Conformity to standards
Material Enclosure
Transparent cover
Reflector(internal)
Reflector(external)
Wire guard
Exposed fastener
Lamp Lamp holder
Available lamp and lamp wattage(W)
Rated voltageEarthing protectionDegree of protectionAmbient temperatureConnecting terminalCable entriesCable gland(option)RemarksWeight
General Catalogue 01.08.2009 http:// www.waromgroup.com
2 Pendant Light Fittings
BAD91 Series Explosion-proof Light Fittings
175W Metal halide lamp*0.61175W High pressure mercury lamp*0.32250W High pressure mercury lamp*0.55150W High pressure sodium lamp*0.65250W High pressure sodium lamp*1.22
Photometric data of 250W metal
halide lamp
Rated luminous flux:23000lm;
The data from PHILIPS lamp;
Luminous intensity distribution cd/1000lm
Photometric data of 250W metal
halide lamp(with spherical reflector)
Rated luminous flux:23000lm;
The data from PHILIPS lamp;
Luminous intensity distribution cd/1000lm
Photometric data of 250W metal
halide lamp(with bevel reflector)
Rated luminous flux:23000lm;
The data from PHILIPS lamp;
Luminous intensity distribution cd/1000lm
Photometric data (BAD91-250)
175W Metal halide lamp*0.61175W High pressure mercury lamp*0.32250W High pressure mercury lamp*0.55150W High pressure sodium lamp*0.65250W High pressure sodium lamp*1.22
175W Metal halide lamp*0.61175W High pressure mercury lamp*0.32250W High pressure mercury lamp*0.55150W High pressure sodium lamp*0.65250W High pressure sodium lamp*1.22
0�Reflection angle CP
0
5
15
25
35
45
55
65
75
85
90
4532
4386
3495
2862
2063
1797
1687
1166
288
85
42
95
105
115
125
135
145
155
165
175
180
29
14
8
5
6
7
7
8
7
6
0
5
15
25
35
45
55
65
75
85
90
4532
4470
3500
2699
2025
1868
944
253
54
17
12
95
105
115
125
135
145
155
165
175
180
7
4
6
7
8
9
10
11
8
7
90�Reflection angle CPAngle
0
5
10
15
20
25
30
35
40
45
50
55
CP
6806
6873
6059
5109
4242
3672
3206
2538
2451
2010
1886
1983
Angle
60
65
70
75
80
85
90
95
100
105
110
115
CP
1883
1790
1471
1038
407
139
70
47
36
25
19
12
Angle
120
125
130
135
140
145
150
155
160
165
170
175
180
CP
9
8
6
4
5
5
6
6
7
7
8
7
6
2/60
Angle
0
5
10
15
20
25
30
35
40
45
50
55
CP
2318
1841
1444
1221
1425
1318
1433
1682
1826
2059
2294
2323
Angle
60
65
70
75
80
85
90
95
100
105
110
115
CP
2409
2434
2474
2526
2454
2413
2343
2290
2116
1591
943
372
Angle
120
125
130
135
140
145
150
155
160
165
170
175
180
CP
98
54
41
30
21
14
10
7
5
4
4
4
3
We can provide lighting designs and lighting data by using professional lighting calculation software DIALUX of Germany upon
stimulated situation and working conditions at user’s request.
General Catalogue 01.08.2009 http:// www.waromgroup.com
2
===II 2G Exde II CT3
Ex tD A21 IP65 T200�
LCIE 08 ATEX 6112
PCEC (China)
EN 60079-0:2004; EN 60079-1:2004; EN 60079-7:2003;
IEC 60079-0:2004; IEC 60079-1:2003; IEC 60079-7:2001
IEC 61241-0:2004; IEC 61241-1:2004
Copper-free aluminium, powder coated, yellow
Toughened glass, stands 4J impact
High purity aluminium
Pure aluminium, anodicoxidation treatment for surface
Stainless steel
Stainless steel
E40
High pressure sodium lamp (HSE): 400W
High pressure mercury lamp (HME): 400W
Metal halide lamp (HIE): 400W
Note: HPI European standard lamp ballast is available in general
AC 220V�240V 50Hz
M5(earthing bolt inside and outside of the light fittings)
IP65
-20��+55�
Terminal 3 x 1.5�2.5mm2 (L+N+PE)
2-M25 x 1.5 Plug
Exe Cable gland DQM-I, manufactured by Warom, please see P7/17�18.
The light fittings are supplied without lamp.
20.00kg
BAD91-400
2/61
Mounting versions
Pendant Light Fittings
BAD91 Series Explosion-proof Light Fittings
ceiling
mounting
wall mounting 30�
wall mounting 90�
Technical data
Explosion-proof light fittings
Explosion protection Gas explosion protection
Dust explosion protection
Certificates For gas explosion protection
For dust explosion protection
Conformity to standards
Material Enclosure
Transparent cover
Reflector(internal)
Reflector(external)
Wire guard
Exposed fastener
Lamp Lamp holder
Available lamp and lamp wattage(W)
Rated voltageEarthing protectionDegree of protectionAmbient temperatureConnecting terminalCable entriesCable gland(option)RemarksWeight
General Catalogue 01.08.2009 http:// www.waromgroup.com
2
Angle
0
5
10
15
20
25
30
35
40
45
50
55
CP
1743
1610
1563
1669
1780
1879
1865
1694
2316
2413
2414
2504
Angle
60
65
70
75
80
85
90
95
100
105
110
115
CP
2852
3055
3200
3028
2857
2729
2761
2996
2930
2787
2600
1963
Angle
120
125
130
135
140
145
150
155
160
165
170
175
180
CP
1005
184
101
73
60
51
49
52
50
57
6
6
6
400W High pressure sodium lamp*1.26400W High pressure mercury lamp*0.58
Rated luminous flux:38000lm;
The data from PHILIPS lamp;
Luminous intensity distribution cd/1000lm
Photometric data of 400W metal
halide lamp(with spherical reflector)
Rated luminous flux:38000lm;
The data from PHILIPS lamp;
Luminous intensity distribution cd/1000lm
Photometric data of 400W metal
halide lamp(with bevel reflector)
Rated luminous flux:38000lm;
The data from PHILIPS lamp;
Luminous intensity distribution cd/1000lm
Photometric data (BAD91-400)
2/62
400W High pressure sodium lamp*1.26400W High pressure mercury lamp*0.58
400W High pressure sodium lamp*1.26400W High pressure mercury lamp*0.58
Angle
0
5
10
15
20
25
30
35
40
45
50
55
CP
1743
1610
1563
1669
1780
1879
1865
1694
2316
2413
2414
2504
Angle
60
65
70
75
80
85
90
95
100
105
110
115
CP
2852
3055
3200
3028
2857
2729
2761
2996
2930
2787
2600
1963
Angle
120
125
130
135
140
145
150
155
160
165
170
175
180
CP
1005
184
101
73
60
51
49
52
50
57
6
6
6
Pendant Light Fittings
BAD91 Series Explosion-proof Light Fittings
0�Reflection angle CP
0
5
15
25
35
45
55
65
75
85
90
6366
6629
5891
5155
4518
4207
3914
3680
3235
2640
1295
6366
6320
5671
4462
3919
3475
3034
2875
523
139
80
95
105
115
125
135
145
155
165
175
180
90�Reflection angle CP
451
128
54
16
8
9
12
11
11
11
48
16
10
11
12
12
12
12
12
12
0
5
15
25
35
45
55
65
75
85
90
95
105
115
125
135
145
155
165
175
180
We can provide lighting designs and lighting data by using professional lighting calculation software DIALUX of Germany upon
stimulated situation and working conditions at user’s request.
Photometric data of 400W metal
halide lamp
General Catalogue 01.08.2009 http:// www.waromgroup.com
2Accessories table
Picture Accessories fittings Ordering code Weight (kg)
250 Wire guard
400 Wire guard
250 Glass cover
400 Glass cover
250 Spherical reflector
400 Spherical reflector
250 Bevel reflector
400 Bevel reflector
271001
271002
271003
271004
271005
271006
271007
271008
0.65
0.87
2.65
4.80
0.37
0.52
0.35
0.49
N150 (HSE150)
L175 (HIE175)
G175 (HME175)
N250 (HSE250)
L250 (HIE250)
G250 (HME250)
L400 (HIE400)
N400 (HSE400)
G400 (HME400)
61028
61029
61041
61030
61031
61042
61032
61033
61043
2.05
2.00
2.02
2.10
2.10
2.20
2.90
2.96
3.00
2/63
Pendant Light Fittings
BAD91 Series Explosion-proof Light Fittings
General Catalogue 01.08.2009 http:// www.waromgroup.com
2
�
�
�
�
�
�
�
BAT51-��Series Explosion-proof Spot Lights
2/64
�=Selection table
�=Ordering note
�=Catalogue number logic
Available lamp wattage (W)
HIE
175, 250, 400
1000
HME
175, 250, 400
-
HSE
150, 250, 400
1000
SME
250, 500
-
Type/Ordering code
14.50
75.50
BAT51-400
BAT51-1000
Weight (kg)
iìãáåçìë=áåíÉåëáíó=ÇáëíêáÄìíáçåEÅÇLNMMMäãF
=BAT51 -=�=�
Lighting Technology
Zones 1C2
Explosion protection to
-CENELEC
-IEC
Can be used
in Zone 1 and Zone 2
Available lamp: high pressure sodium lamp, metal halide
lamp, high pressure mercury lamp and self ballast mercury
lamp, with E40 lamp holder.
Enclosure has two versions: 400 and 1000.
Enclosure in copper-free aluminium, powder coated, yellow.
The light body can be adjusted within 360�horizontally ,in
elevation 60��90�for large area lighting.
Toughened glass cover, impact resistance and high light
transmission.
Lamp wattage(W)
HIE: Metal halide lamp
HSE: High pressure sodium lamp
HME: High pressure mercury lamp
SME: Self ballast mercury lamp
1.The light fittings are supplied without lamp, if required, PHILIPS lamps are recommended.If metal halide lamp required, HPI Euro
pean standard ballast will be supplied, please use HPI European standard lamp.
2.Possible to supply power compensation capacitor, power factor cosø � 0.85. If required, please specify.
3.Light fittings of 1000 version are supplied with lamp and ballast, please specify the type of lamp when place an order.
Lamp
Explosion-proof spot lights
General Catalogue 01.08.2009 http:// www.waromgroup.com
2Spot Lights
BAT51 Series Explosion-proof Spot Lights
2/65
BAT51-400
Dimensional drawings
BAT51-400 Ground mounting BAT51-400 Ceiling mounting
BAT51-1000
II 2G Exd II BT2
PCEC (China)
BAT51-1000
II 2G Exd II BT4(T3)
PCEC (China)
IEC 60079-0:2004; IEC 60079-1:2003
Copper-free aluminium, powder coated, yellow.Zinc plated carbon steel, powder coated(white)
Toughened glass, stands 4J impactHigh purity aluminiumStainless steel
E40
220V�240V 50Hz(AC230V 50Hz for 1000W metal halide lamp and high pressure so-dium lamp)M5(earthing bolt inside and outside of the light fittings)
IP65-20��+55�Terminal 3 x 1.5�2.5mm2 (L+N+PE)
BAT51-400 typeWG3/4”I BAT51-1000 typeWM25 x 1.5BAT51-400 type: with seal ring and trumpet shaped glandBAT51-1000 type: power wires between light fittings and ballast are connected by BNGstainless steel wire explosion-proof pipe connector.
Type:BNG-M25 x 1.5(M)/M25 x 1.5(M), 1000mm long.Cable gland at client cable entries: 1 x DQM-II M25 x 1.5, brass, armored, cable wiring.ø10�ø14 (mm)
1. For BAT51-400 type:if use metal halide lamp, high pressure mercury lamp or high pressure sodium lamp, corresponding explosion-proof ballast shall be equipped. BAZ51 Series explosion-proof ballast manufactured by Warom is recommended,
please see P2/80 for details.2. For BAT51-1000 type:it is supplied with explosion-proof ballast, no need to equip ballast additionally. If use metal halide lamp, please choose HPI European standard
metal halide lamp.
Technical data
Explosion-proof spot lights
Explosion protection Gas explosion protection
Certificates
For gas explosion protection
Conformity to standardsMaterial Enclosure Wire guard Transparent cover Reflector(internal) Exposed fastenerLamp Lamp holder Lamp wattage(W)
Rated voltage
Earthing protectionDegree of protectionAmbient temperatureConnecting terminalCable entriesCable gland
Available cable outer diameterRemarks
II 2G Exd II BT4HIEHSEHMESME
Available lamp175W, 250W150W, 250W175W, 250W
250W
II 2G Exd II BT3400W400W400W500W
1000W1000W
II 2G Exd II BT2
General Catalogue 01.08.2009 http:// www.waromgroup.com
2
�
�
�
�
�
�
�
BAT53- ��� Series Explosion-proof
Floodlights
2/66
BAT53-125
BAT53-250
BAT53-400
BAT53-1000
6.50
13.00
28.00
75.00
Available lamp wattage (W)
70, 100, 150
175, 250
400
1000
80, 125
175, 250
-
-
E27
E40
E40
E40
Lamp holder Weight (kg)Type/Ordering code
�=Catalogue number logic
�=Selection table
�=Ordering note
70, 100
150, 250
400
1000
=BAT53 - �=�=�
Mounting
Explosion-proof floodlights
Lamp
Lamp wattage (W)
Y: movable mountingG: fixed mounting
HIE HSE HME
Lighting Technology
Zones 1C2X 21C22
Explosion protection to
-CENELEC
-IEC
Can be used
in Zone 1 and Zone 2
in Zone 21 and Zone 22
Enclosure has four versions: 125, 250, 400 and 1000.
Integral structure with the lamp, the ballast, convenient to
maintain.
Common explosion-proof trigger, quick starting, stable per-
formance and long service life.
Enclosure in copper-free aluminium, powder coated, yellow.
Toughened glass cover, impact resistance and high light
transmission.
HIE: Metal halide lampHSE: High pressure sodium lampHME: High pressure mercury lamp
1.Specify all data at request of “catalogue number logic”.
2.If accessories are required, please purchase as the “Accessories table” or at guide of “ordering code”.
3.The light fittings are supplied without lamp, if required, PHILIPS lamps are recommended. If metal halide lamp required, HPI Euro-
pean standard ballast will be supplied, please use HPI European standard lamp.
4.Possible to supply power compensation capacitor, power factor cosø � 0.85. If required, please specify.
General Catalogue 01.08.2009 http:// www.waromgroup.com
2
2/67
===II 2G Exde II BT4
Ex tD A21 IP65 T135�
LCIE 05 ATEX 6143; IECEx CQM 07.0004;
PCEC (China)
EN 60079-0:2004; EN 60079-1:2004; EN 60079-7:2003;
IEC 60079-0:2004; IEC 60079-1:2003; IEC 60079-7:2001
IEC 61241-0:2004; IEC 61241-1:2004
Copper-free aluminium, powder coated, yellow.
Inductive ballast, quick starting, stable performance
Zinc plated carbon steel, powder coated(white)
High purity aluminium
Common explosion-proof trigger
Explosion-proof capacitor, it is not supplied with standard products, but available at
user’s request.
Stainless steel
E27
High pressure sodium lamp (HSE): 70W, 100W
High pressure mercury lamp (HME): 80W, 125W
Metal halide lamp (HIE): 70W, 100W, 150W
Note: HPI European standard lamp ballast is available in general
AC 220V�240V 50Hz
M5(earthing bolt inside and outside of the light fittings)
IP65
-20��+55�
Terminal 3 x 1.5�2.5mm2 (L+N+PE)
2 x ø21, 1 x M20 x 1.5 Cable gland(DQM-I, carbon steel),1 x M20 x 1.5 Plug
ø5�ø10 (mm)
BAT53- � 125 �
Floodlights
BAT53 Series Explosion-proof Floodlights
Photometric data Dimensional drawings
Photometric data of
100W metal halide lampRated luminous flux:9000lm;
Luminous intensity distribution
cd/1000lm
Angle
0
5
10
15
20
25
30
35
40
45
CP
1948
1945
1953
1963
1950
1955
1839
1733
1649
1588
Angle
50
55
60
65
70
75
80
85
90
CP
1370
612
385
236
131
66
37
0
0
Y: movable mounting
G: fixed mounting
70W Metal halide lamp*0.5670W High pressure sodium lamp*0.67100W High pressure sodium lamp*1.0680W High pressure mercury lamp*0.41125W High pressure mercury lamp*0.68150W Metal halide lamp*1.66
Technical data
Explosion-proof floodlightsExplosion protection Gas explosion protection
Dust explosion protection
Certificates For gas explosion protection
For dust explosion protection
Conformity to standards
Material Enclosure
Ballast
Wire guard
Reflector(internal)
Trigger
Capacitor
Exposed fastener
Lamp Lamp holder
Available lamp and lamp wattage(W)
Rated voltageEarthing protectionDegree of protectionAmbient temperatureConnecting terminalCable entriesAvailable cable outer diameter
General Catalogue 01.08.2009 http:// www.waromgroup.com
2
===II 2G Exde II BT3
Ex tD A21 IP65 T200�
LCIE 05 ATEX 6143; IECEx CQM 07.0004;
PCEC (China)
EN 60079-0:2004; EN 60079-1:2004; EN 60079-7:2003;
IEC 60079-0:2004; IEC 60079-1:2003; IEC 60079-7:2001
IEC 61241-0:2004 ; IEC 61241-1:2004
Copper-free aluminium, powder coated, yellow.
Inductive ballast, quick starting, stable performance
Zinc plated carbon steel, powder coated(white)
High purity aluminium
Common explosion-proof trigger
Explosion-proof capacitor, it is not supplied with standard products, but available at user’s request.
Stainless steel
E40
High pressure sodium lamp (HSE): 150W, 250W
High pressure mercury lamp (HME): 175W, 250W
Metal halide lamp (HIE): 175W, 250W
Note: HPI European standard lamp ballast is available in general
AC 220V�240V 50Hz
M5(earthing bolt inside and outside of the light fittings)
IP65
-20��+55�
Terminal 3 x 1.5�2.5mm2 (L+N+PE)
2 x ø26�1 x M25 x 1.5 Cable gland(DQM-I ,carbon steel),1 x M25 x 1.5 Plug
ø10�ø14 (mm)
BAT53-� 250 �
Floodlights
BAT53 Series Explosion-proof Floodlights
2/68
Explosion-proof floodlights
Dimensional drawings
Angle
0
5
10
15
20
25
30
35
40
45
CP
3162
3197
3183
3128
3073
3010
2790
2505
2191
1806
Angle
50
55
60
65
70
75
80
85
90
CP
1419
975
613
354
202
127
65
5
3
Y: movable mounting
G: fixed mounting
175W Metal halide lamp*0.61
150W High pressure sodium lamp*0.65
250W High pressure sodium lamp*1.22
175W High pressure mercury lamp*0.32
250W High pressure mercury lamp*0.55
Technical data
Explosion protection Gas explosion protection
Dust explosion protection
Certificates For gas explosion protection
For dust explosion protection
Conformity to standards
Material Enclosure
Ballast
Wire guard
Reflector(internal)
Trigger
Capacitor
Exposed fastener
Lamp Lamp holder
Available lamp and lamp wattage(W)
Rated voltageEarthing protectionDegree of protectionAmbient temperatureConnecting terminalCable entriesAvailable cable outer diameter
Photometric data of
250W metal halide lampRated luminous flux:23000lm;
Luminous intensity distribution
cd/1000lm
Photometric data
General Catalogue 01.08.2009 http:// www.waromgroup.com
2
===II 2G Exde II BT3
Ex tD A21 IP65 T200�
LCIE 07 ATEX 6106; IECEx CQM 08.0014; MC,AEX-8549(Brazil)
PCEC (China)
EN 60079-0:2004; EN 60079-1:2004; EN 60079-7:2003;
IEC 60079-0: 2004; IEC 60079-1:2003; IEC 60079-7:2001
IEC 61241-0:2004 ; IEC 61241-1:2004
Copper-free aluminium, powder coated, yellow.
Inductive ballast, quick starting, stable performance
High purity aluminium
Common explosion-proof trigger
Explosion-proof capacitor, it is not supplied with standard products, but available at
user’s request.
Stainless steel
E40
High pressure sodium lamp (HSE): 400W(tubular)
Metal halide lamp (HIE): 400W(tubular)
Note: HPI European standard lamp ballast is available in general
AC 220V�240V 50Hz
M5(earthing bolt inside and outside of the light fittings)
IP65
-20��+55�
Terminal 3 x 1.5�2.5mm2 (L+N+PE)
2 x M25 x 1.5�1 x M25 x 1.5 Cable gland(DQM-I, carbon steel),1 x M25 x 1.5 Plug
ø10�ø14 (mm)
BAT53- � 400�
2/69
Floodlights
BAT53 Series Explosion-proof Floodlights
Explosion-proof floodlights
Photometric data Dimensional drawings
Photometric data of
400W metal halide lampRated luminous flux:38000lm;
Luminous intensity distribution
cd/1000lm
Angle
0
5
10
15
20
25
30
35
40
45
CP
5982
6178
6103
6054
5706
5342
4751
4235
3517
2765
Angle
50
55
60
65
70
75
80
85
90
CP
2330
1849
443
338
234
111
52
12
4
400W High pressure sodium lamp*1.26
Technical data
Explosion protection Gas explosion protection
Dust explosion protection
Certificates For gas explosion protection
For dust explosion protection
Conformity to standards
Material Enclosure
Ballast
Reflector(internal)
Trigger
Capacitor
Exposed fastener
Lamp Lamp holder
Available lamp and lamp wattage(W)
Rated voltageEarthing protectionDegree of protectionAmbient temperatureConnecting terminalCable entriesAvailable cable outer diameter
General Catalogue 01.08.2009 http:// www.waromgroup.com
2
===II 2G Exd II BT2
PCEC (China)
IEC 60079-0: 2004; IEC 60079-1: 2003
Copper-free aluminium, powder coated, yellow.
Inductive ballast, quick starting, stable performance
High purity aluminium
Stainless steel
E40
High pressure sodium lamp (HSE):1000W
Metal halide lamp (HIE):1000W
Note: HPI European standard lamp ballast is available in general
AC 230V 50Hz
M5(earthing bolt inside and outside of the light fittings)
IP65
-20��+55�
Terminal 3 x 1.5�2.5mm2 (L+N+PE)
1 x M25 x 1.5
Power wires between light fittings and ballast are connected by BNG stainless steel
wire explosion-proof pipe connector.
Type: BNG-M25 x 1.5(M)/M25 x 1.5(M), 1000mm long.
Cable gland at client cable entries: 1 x DQM-II M25 x 1.5, brass, armored, cable wiring.
ø10�ø14 (mm)
BAT53-� 1000 �
Dimensional drawings
BAT53-1000
2/70
Explosion-proof floodlights
Floodlights
BAT53 Series Explosion-proof Floodlights
Technical data
Explosion protection
Gas explosion protection
Certificates
For gas explosion protection
Conformity to standards
Material
Enclosure
Ballast
Reflector(internal)
Exposed fastener
Lamp
Lamp holder
Available lamp and lamp wattage(W)
Rated voltage
Earthing protection
Degree of protection
Ambient temperature
Connecting terminal
Cable entries
Cable gland
Available cable outer diameter
General Catalogue 01.08.2009 http:// www.waromgroup.com
2
2/71
�=Open the ballast case, select right cables, pass them through cable entries
to connect to the connection base inside. Correctly connect, press down, en-
suring no looseness and falling off. Then lock cable gland, close the cover, and
tighen the bolt.
For 400 version, the ballast case is placed at back of the light fittings, with
highe. When connet wires, just need to loosen the tightening bolt and unscrew
the ballast case.
Power connection
�=Counter clockwise unscrew the cover on top of lamp case (at the side of
lamp case for 400 and 1000 versions), screw right lamp into lamp holder and
screw down it without looseness and falling off, ensuring good electric contact.
Then clockwise screw down cover and ensure good seal performance. By the
same steps for relamp.
1.360
1.350
1.439
1.800
1.750
1.760
2.050
2.000
2.177
2.100
2.100
2.200
2.960
2.900
10.65
10.50
250 Ballast
400 Ballast
N70 (HSE70)
L70 (HIE70)
G80 (HME80)
N100 (HSE100)
L100 (HIE100)
G125 (HME125)
N150 (HSE150)
L175 (HIE175)
G175 (HME175)
N250 (HSE250)
L250 (HIE250)
G250 (HME250)
L400 (HIE400)
N400 (HSE400)
N1000 (HSE1000)
L1000 (HIE1000)
53001
53002
53026
53003
53004
53027
53005
53007
53028
53006
53008
53029
53009
53010
53030
53031
Explosion-proof trigger 61034 0.314
1000 Ballast
125 Ballast
125 Explosion-proof capacitor
250=Explosion-proof capacitor
400=Explosion-proof capacitor
125 Movable support
250 Movable support
53012
53013
53014
53015
53016
0.450
0.450
0.510
1.800
2.350
Accessories table
Picture Accessories fittings Ordering code Weight (kg)
Floodlights
BAT53 Series Explosion-proof Floodlights
General Catalogue 01.08.2009 http:// www.waromgroup.com
2
�
�
�
�
�
�
�
�
�
BAT54-��Series Explosion-proof Floodlights
2/72
Luminous intensity distribution(cd/1000lm)
�=Catalogue number logic
�=pÉäÉÅíáçå=í~ÄäÉ
�=Ordering note
Lighting Technology
=BAT54 - �=�
BAT54-400
BAT54-1000
Available lamp wattage(W)
HIE
250, 400
1000
HME
250, 400
-
HSE
250, 400
1000
Type/Ordering code
7.20
10.50
Weight (kg)
Zone 2
Explosion protection to
-CENELEC
-IEC
Can be used
in Zone 2
Available lamp holder: E40
- High pressure sodium lamp,
- High pressure mercury lamp
- Metal halide lamp
Enclosure has two versions: 400 and 1000.
Enclosure in welded stainless steel plate, light.
Integral structure with the lamp, the ballast, convenient to
maintain.
Seal strip between cover and enclosure, fastened by agraffe
for immediate starting and convenient maintenance.
The light body can be adjusted in elevation 45��90�.
Toughened glass, impact resistance and high light
transmission.
Lamp wattage(W)
Lamp
Explosion-proof floodlights
HIE: Metal halide lampHSE: High pressure sodium lampHME: High pressure mercury lamp
1.Specify all data at request of “catalogue number logic”.
2.The light fittings are supplied without lamp, if required, PHILIPS lamps are recommended.If metal halide lamp required, HPI Euro-
pean standard ballast will be supplied, please use HPI European standard lamp.
3..The light fittings are supplied wihtout ballast. If required, BAZ51 Series explosion-proof ballast made of stainless steel manufac-
tured by Warom is recommended, please see P2/82 for details.
General Catalogue 01.08.2009 http:// www.waromgroup.com
2
2/73
BAT54-400 BAT54-1000
Floodlights
BAT54 Series Explosion-proof Floodlights
Dimensional drawings
Explosion-proof floodlights
Technical data
Explosion protection
Gas explosion protection
Certificates
For gas explosion protection
Conformity to standards
Material
Enclosure
Ballast
Reflector(internal)
Exposed fastener
Lamp
Lamp holder
Available lamp and lamp wattage(W)
Rated voltage
Earthing protection
Degree of protection
Ambient temperature
Connecting terminal
Cable gland
Available cable outer diameter
Remarks
===II 2G ExnR II T3(T2); T3 for=400W and below, T2 for 1000W
PCEC (China)
IEC 60079-0: 2004; IEC 60079-15: 2005
Stainless steel plate, light, corrosion protection
Inductive ballast, quick starting, stable performance
High purity aluminium
Stainless steel
E40
High pressure sodium lamp (HSE): 250W, 400W, 1000W
High pressure mercury lamp (HME): 250W, 400W
Metal halide lamp (HIE): 250W, 400W, 1000W
AC 220V�240V 50Hz (AC230V 50Hz for 1000W metal halide lamp and high pressure
sodium lamp)
M5(earthing bolt inside and outside of the light fittings))
IP65
-20��+55�
Terminal 3 x 1.5�2.5mm2 (L+N+PE)
1 x G3/4” Cable gland=(DQM-I,stainless steel)
ø10�ø14 (mm)
1. The light fittings are supplied without explosion-proof ballast, if required, please
purchase separately.
2. For 1000W lamp, please specify if ballast required.
General Catalogue 01.08.2009 http:// www.waromgroup.com
2
�
�
�
�
�
�
BAT85-��Series Explosion-proof Floodlights
2/74
BAT85- �� 25.00
Available lamp wattage (W)
175, 250, 400 175, 250, 400 E40
Lamp holder Weight (kg)Type/Ordering code
�=Catalogue number logic
�=Selection table
150, 250, 400
HIE HSE HME
Zones 1C2
=BAT85 - �=�
Explosion protection to
-CENELEC
-IEC
Can be used
in Zone 1 and Zone 2
Available lamp : type 250 and type 400.
Enclosure in copper-free aluminium, powder coated, yellow.
Integral structure with the lamp, the ballast, convenient to
maintain.
Toughened glass, high light transmission, stands 4J impact.
Lamp wattage(W)
Lamp
Explosion-proof floodlights
HIE: Metal halide lampHSE: High pressure sodium lampHME: High pressure mercury lamp
�=Ordering note
1.Specify all data at request of “catalogue number logic”,
2.If accessories are required, please purchase as the “Accessories table” or at guide of “ordering code”.
3.The light fittings are supplied without lamp, if required, PHILIPS lamps are recommended. If metal halide lamp required, HPI Euro-
pean standard ballast will be supplied, please use HPI European standard lamp.
4.Possible to supply power compensation capacitor, power factor cosø � 0.85. If required, please specify.
Lighting Technology
General Catalogue 01.08.2009 http:// www.waromgroup.com
2
2/75
===II 2G Exd II CT3
LCIE 09 ATEX
EN 60079-0:2007; EN 60079-1:2007
IEC 60079-0:2007; IEC 60079-1:2007
Copper-free aluminium, powder coated, yellow.
Toughened glass, stands 4J impact
Inductive ballast, quick starting, stable performance
High purity aluminium
Stainless steel
E40
Metal halide lamp (HIE): 175W, 250W, 400W
Note: HPI European standard lamp ballast is available in general
High pressure sodium lamp (HSE): 150W, 250W, 400W
High pressure mercury lamp (HME): 175W, 250W, 400W
AC 220V�240V 50Hz
M5(earthing bolt inside and outside of the light fittings)
IP65
-20��+55�
Termianl 3 x 1.5�2.5mm2 (L+N+PE)
2 x M25 x 1.5 Plug
Exd cable gland=DQM-II, manufactured by Warom, please see P7/20�23.
Explosion-proof floodlights BAT85-��
Floodlights
BAT85 Series Explosion-proof Floodlights
Dimensional drawings
Technical data
Explosion protection
Gas explosion protection
Certificates
For gas explosion protection
Conformity to standards
Material
Enclosure
Glass sheet
Ballast
Reflector
Exposed fastener
Lamp
Lamp holder
Available lamp
Rated voltage
Earthing protection
Degree of protection
Ambient temperature
Connecting terminal
Cable entries
Cable gland(option)
General Catalogue 01.08.2009 http:// www.waromgroup.com
2
Photometric data of 250W metal halide lamp
Rated luminous flux:20000lm;
The data from PHILIPS lamp;
Luminous intensity distribution cd/1000lm
Photometric data of 400W metal halide lamp
Rated luminous flux:38000lm;
The data from PHILIPS lamp;
Luminous intensity distribution cd/1000lm
Photometric data
Angle
50
55
60
65
70
75
80
85
90
CP
488
212
150
110
79
58
36
0
0
Angle
0
5
10
15
20
25
30
35
40
45
CP
2964
2988
3115
2991
2879
2543
2319
2324
2140
1674
Angle
50
55
60
65
70
75
80
85
90
CP
2373
1015
440
257
305
220
86
0
0
Angle
0
5
10
15
20
25
30
35
40
45
CP
5076
5138
5038
4975
4951
4691
4279
3681
3385
3156
2/76
Floodlights
BAT85 Series Explosion-proof Floodlights
175W Metal halide lamp*0.61
150W High pressure sodium lamp*0.65
250W High pressure sodium lamp*1.22
175W High pressure mercury lamp*0.32
250W High pressure mercury lamp*0.55
400W High pressure sodium lamp*1.26
400W High pressure mercury lamp*0.58
We can provide lighting designs and lighting data by using professional lighting calculation software DIALUX of Germany upon
stimulated situation and working conditions at user’s request.
General Catalogue 01.08.2009 http:// www.waromgroup.com
2Floodlights
BAT85 Series Explosion-proof Floodlights
2/77
Accessories table
Picture Accessories fittings Ordering code Weight (kg)
N150 (HSE150)
L175 (HIE175)
G175 (HME175)
N250 (HSE250)
L250 (HIE250)
G250 (HME250)
L400 (HIE400)
N400 (HSE400)
G400 (HME400)
61028
61029
61041
61030
61031
61042
61032
61033
61043
2.05
2.00
2.02
2.10
2.10
2.20
2.90
2.96
3.00
�=Open the ballast case at bottom of the light fittings, select right cables, pass
them through cable entries to connect to the connection base inside. Correctly
connect, press down, ensuring no looseness and falling off. Then lock cable
gland, close the cover (please take note to protect the flameproof threads).
Power connection and lamp fixing
�=Counter clockwise unscrew the cover at the side of lamp case, screw right
lamp into lamp holder and screw down it without looseness and falling off, en-
suring good electric contact. Then clockwise screw down cover and ensure
good seal performance. By the same steps for relamp (please take note to
protect the flameproof threads).
General Catalogue 01.08.2009 http:// www.waromgroup.com
2
�
�
�
�
�
BAT53-250, BAT53-400 Type
BAD71-250, BAD71-400 Type
BAD91-250, BAD91-400 Type
Street Mounted Explosion-proof Lamps
2/78
Mounting schematic diagram of BAT53-250 type street lamp
�=Note: Diameter of connecting light fittings is ø60.
Explosion protection to
-CENELEC
-IEC
Can be used
in Zone 1 and Zone 2
in Zone 21 and Zone 22
Please refer to below mounting shcematic diagram to select
right lamp and mounting versions at request of job site,
Please refer to this catalogue for technical data and ordering
information of each light fittings.
Note: If mounting version of BAT53-250 type street lamp
required, please specify when order.
The street lamps are supplied without lamp pole, if required ,
possible to supply, please contact us or our local office.
Lighting Technology
Zones 1C2X 21C22
General Catalogue 01.08.2009 http:// www.waromgroup.com
2Mounting schematic diagram of BAT53-250, BAT53-400 type, BAD71-250, BAD71-400 type, BAD91-250, BAD91-400 type street lamps
2/79
Reference diagram of street lamp mounting base
Note: For BAD71-250, BAD71-400,BAD91-400 type and BAD91-250 type, the installation angle of light fittings
can be adjusted at the request of lighting on job site. The external reflector is also can be installed to increase
the luminous intensity of working face.
Platform mounting
(Multiple lamps)
Platform mounting
(Single lamp)
Platform mounting
(Single lamp)
Platform mounting
(Multiple lamps)
BAD71-250, BAD71-400 type
BAD91-250, BAD91-400 type
BAT53-250, BAT53-400 type
Street Lamps
Street Mounted Explosion-proof Lamps
General Catalogue 01.08.2009 http:// www.waromgroup.com
2
�
�
�
�
�
�
BAZ51- �� Series Explosion-proof Ballast
2/80
=BAZ51 -=�=�
Lamp wattage(W)
Lamp
Explosion-proof ballast
Type/Ordering code
BAZ51-HIE 70
BAZ51-HIE 100
BAZ51-HIE 150
BAZ51-HIE 175
BAZ51-HIE 250
BAZ51-HIE 400
BAZ51-HSE 70
BAZ51-HSE 100
Remarks:Possible to supply power compensation capacitor, power factor cosø � 0.85. If required, please specify.
Type/Ordering code
BAZ51-HSE 150
BAZ51-HSE 250
BAZ51-HSE 400
BAZ51-HME 80
BAZ51-HME 125
BAZ51-HME 175
BAZ51-HME 250
BAZ51-HME 400
Available lamp wattage(W)
HIE 70
HIE 100
HIE 150
HIE 175
HIE 250
HIE 400
HSE 70
HSE 100
Available lamp wattage(W)
HSE 150
HSE 250
HSE 400
HME 80
HME 125
HME 175
HME 250
HME 400
Enclosure
I
I
I
I
I
II
I
I
Enclosure
I
II
II
I
I
I
I
II
�=Catalogue number logic
�=Selection table
Weight (kg)
6.20
6.60
6.70
6.85
6.95
7.70
6.21
6.65
Weight (kg)
6.90
7.70
8.50
6.30
6.61
7.03
7.05
8.60
Lighting Technology
Zones 1C2X 21C22
Explosion protection to
-CENELEC
-IEC
Can be used
in Zone 1 and Zone 2
in Zone 21 and Zone 22
Applicable to metal halide lamp, high pressure sodium lamp
and high pressure mercury lamp with lamp wattage 400W
and below.
Can be mounted separately as well as block mounted to-
gether with explosion-proof light fittings. If mounted
separately, please match it with BAT51-400 of Warom for
external mounting, If block mounted, please match it with
BAD series products of Warom for mounting of pendant light
fittings.
Enclosure in copper-free aluminium, powder coated, yellow.
Inductive ballast, quick starting, stable performance.
HSE: High pressure sodium lampHME: High pressure mercury lampHIE: Metal halide lamp
General Catalogue 01.08.2009 http:// www.waromgroup.com
2Ballast
BAZ51 Series Explosion-proof Ballast
2/81
BAZ51- ��
Dimensional drawings
I
II
A
240
250
Size (mm)
B
301
331
C
135
140
D
265
295
E
65
65
Enclosure
I
II
A
245
265
Size (mm)
B
301
331
C
135
140
D
265
295
E
65
65
Enclosure
Outline 1(For block mounting, for example: used for series BAD) Outline 2(For block mounting, for example: used for series BAT51-400)
Wiring diagram of light fittings and ballast
Wiring diagram 1(For high pressure sodium lamp and metal halide lamp) Wiring diagram 2(For high pressure mercury lamp)
Explosion-proof ballast
Technical data
Explosion protection Gas explosion protection Dust explosion protectionCertificates For gas explosion protection For dust explosion protectionConformity to standards
Material Enclosure Exposed fastenerAvailable lamp and lampwattage(W)
Rated voltage
Earthing protectionDegree of protectionAmbient temperatureConnecting terminalCable entriesCable gland(option)
===II 2G Exd II BT6
Ex tD A21 IP65 T85�
LCIE 06 ATEX 6019; IECEx LCI 08. 0002;
PCEC (China)
EN 60079-0:2004; EN 60079-1:2004; IEC 60079-0:2004 ; IEC 60079-1:2003
IEC 61241-0:2004 ; IEC 61241-1:2004
Copper-free aluminium, powder coated, yellow.
Stainless steel
High pressure sodium lamp (HSE): 70W, 100W, 150W, 250W, 400W
High pressure mercury lamp (HME): 80W, 125W, 175W, 250W, 400W
Metal halide lamp (HIE): 70W, 100W, 150W, 175W, 250W, 400W
Note: HPI European standard lamp ballast is available in general
AC 220V�240V 50Hz
Note: If any special requirements for power voltage, please specify when order.
M5(earthing bolt inside and outside of the light fittings)
IP65
-20��+55�
Terminal 3 x 1.5�2.5mm2 (L+N+PE)
3 x M25 x 1.5
Standard assemblies for independent mounting: 3 x M25 x 1.5 Plug;Exd cable gland
(option) DQM-II, manufactured by Warom, please see P7/20�23;
Standard assemblies for block mounting: 2 x M25 x 1.5 Plug; Exd cable gland (option)
DQM-II, manufactured by Warom, please see P7/20�23; With cable-clamped seal
ring and pressing plate at cable entries at bottom.
General Catalogue 01.08.2009 http:// www.waromgroup.com
2
�
�
�
�
�
�
�
BAZ51-e�� Series Explosion-proof Ballast
2/82
�=Catalogue number logic
Zones 1C2
=BAZ51-e -=�=�
HSE: High pressure sodium lamp
HME: High pressure mercury lamp
HIE: Metal halide lamp
Type/Ordering code
BAZ51-e-HIE 70
BAZ51-e-HIE 100
BAZ51-e-HIE 150
BAZ51-e-HIE 175
BAZ51-e-HIE 250
BAZ51-e-HIE 400
BAZ51-e-HIE 1000
BAZ51-e-HSE 70
BAZ51-e-HSE 100
Type/Ordering code
BAZ51-e-HSE 150
BAZ51-e-HSE 250
BAZ51-e-HSE 400
BAZ51-e-HSE 1000
BAZ51-e-HME 80
BAZ51-e-HME 125
BAZ51-e-HME 175
BAZ51-e-HME 250
BAZ51-e-HME 400
Available lamp wattage(W)
HIE 70
HIE 100
HIE 150
HIE 175
HIE 250
HIE 400
HIE 1000
HSE 70
HSE 100
Available lamp wattage(W)
HSE 150
HSE 250
HSE 400
HSE 1000
HME 80
HME 125
HME 175
HME 250
HME 400
Enclosure
I
I
I
I
I
II
III
I
I
Enclosure
I
II
II
III
I
I
I
I
II
�=Selection table
Weight (kg)
3.20
3.60
3.70
3.80
3.90
6.50
13.50
3.00
3.60
Weight (kg)
3.80
4.70
6.50
13.50
3.00
3.60
3.80
3.90
4.70
Explosion protection to
-CENELEC
-IEC
Can be used
in Zone 1 and Zone 2
Applicable to metal halide lamp, high pressure sodium lamp
and high pressure mercury lamp with lamp wattage 1000W
and below.
Enclosure in welded stainless steel plate, light, corrosion
protection.
This product is used together with BAT54 series products of
Warom.
Enclosure has three specifications: I, II and III.
Inductive ballast, quick starting, stable performance.
Lamp wattage(W)
Lamp
Explosion-proof ballast
Remarks: Possible to supply power compensation capacitor, power factor cosø � 0.85. If required, please specify.
Lighting Technology
General Catalogue 01.08.2009 http:// www.waromgroup.com
2Ballast
BAZ51-e Series Explosion-proof Ballast
2/83
===II 2G Exe II T4
PCEC (China)
IEC 60079-0:2004 ; IEC 60079-7:2001
Stainless steel
Stainless steel
High pressure sodium lamp (HSE): 70W, 100W, 150W, 250W, 400W, 1000W
High pressure mercury lamp (HME): 80W, 125W, 175W, 250W, 400W
Metal halide lamp (HIE): 70W, 100W, 175W, 250W, 400W, 1000W
Note: HPI European standard lamp ballast is available in general
AC 220V�240V 50HzEAC230V 50Hz for 1000W metal halide lamp and high pres-
sure sodium lampF
M5(earthing bolt inside and outside of the light fittings)
IP65
-20��+55�
Terminal 3 x 1.5�2.5mm2 (L+N+PE)
Type I, Type II: 2 x ø26, 1 x M25 x 1.5; Type III: 3 x ø26
Type I, Type II: 2 x M25 x 1.5 Cable gland(DQM-I, plastic), 1 x M25 x 1.5 Plug
Type III: 3 x M25 x 1.5 Cable gland(DQM-I, plastic)
ø10�ø14mm
Explosion-proof ballast BAZ51-e-��
Dimensional drawings
I
II
A
152
160
Size (mm)
B
170
210
C
122
122
D
70
70
E
194
234
EnclosureF
211
251
Outline of enclosure I and II (for 400W and below)
Outline of enclosure III (for 1000W)
Technical data
Explosion protection
Gas explosion protection
Certificates
For gas explosion protection
Conformity to standards
Material
Enclosure
Exposed fastener
Available lamp and lamp
wattage(W)
Rated voltage
Earthing protection
Degree of protection
Ambient temperature
Connecting terminal
Cable entries
Cable gland(option)
Available cable outer diameter
General Catalogue 01.08.2009 http:// www.waromgroup.com
2
�
�
�
�
�
�
�
BSX-60 Series Explosion-proof Incandescent
Hand Lamps
2/84
Lighting Technology
Zones 1C2
Explosion protection to
-CENELEC
-IEC
Can be used
in Zone 1 and Zone 2
For incandescent lamps up to 60W.
Can be supplied with or without connecting wires.
Handle in engineering plastic, with control pushbutton switch
inside.
Zinc plated wire guard is powder coated, white.
Toughened glass cover, impact resistance and high light
transmission.
General Catalogue 01.08.2009 http:// www.waromgroup.com
2Hand Lamps
BSX Series Explosion-proof Incandescent Hand Lamps
2/85
===II 2G Exde II CT4
LCIE 07 ATEX 6028; IECEx CQM 08.0015; ML,AEX-8531-X(Brazil)
EN 60079-0: 2004; EN 60079-1: 2004; EN 60079-7: 2003;
IEC 60079-0: 2004; IEC 60079-1: 2003; IEC 60079-7: 2001
Copper-free aluminium, powder coated, yellow.
Handle in engineering plastic, black
Built-in explosion-proof control pushbutton, be able to switch on and off the
lamp directly.
Stainless steel
Zinc plated carbon steel, powder coated(white)
E27
Incandescent lamp: 25W, 40W, 60W
Max. 230V
II(Protection against electric shock)
IP65
-20��+55�
Terminal 3 x 1.5�2.5mm2 (L+N+PE)
1 x M25 x 1.5 Cable gland=(DQM-I, plastic)
ø9�ø13 (mm)
2.10kg
Explosion-proof incandescent hand lamps BSX-60
Accessories table
Picture Accessories fittings Ordering code Weight (kg)
Wire guard
Glass cover fittings
BSX101
BSX102
0.303
1.076
Dimensional drawings
Technical data
Explosion protection
Gas explosion protection
Certificates
For gas explosion protection
Conformity to standards
Material
Enclosure
Pushbutton switch
Exposed fastener
Wire guard
Lamp
Lamp holder
Available lamp
Rated voltage
Protection class
Degree of protection
Ambient temperature
Connecting terminal
Cable entries
Available cable outer diameter
Weight
General Catalogue 01.08.2009 http:// www.waromgroup.com
2BAY51-Q � x ��� Series Explosion-proof
Emergency Light Fittings for Fluorescent Lamp
�=Catalogue number logic
2/86
Lighting Technology
�
�
�
�
�
�
�
�
�
Zones 1C2X 21C22
=BAY51-Q � x �=�==J
Emergency lighting
Mounting
Lamp number
Lamp wattage(W)
Explosion-proof emergency light fittings for fluorescent lamp
Explosion protection to
-CENELEC
-IEC
Can be used
in Zone 1 and Zone 2
in Zone 21 and Zone 22
Enclosure has two versions: 1 or 2;
Available lamp wattage; 18W and 36W.
Enclosure in engineering plastic, corrosion protection;
“Exe” enclosure with explosion-proof components inside.
There is explosion-proof switch interlocking gear between
enclosure and transparent cover, the power can be switched
off when open the transparent cover.
Built-in electronic ballast, power factor � 0.95.
With protection against dissymmetry power of lamp tube.
Emergency unit has protection against over charge and over
discharge.
L: pole mounting
X: ceiling mounting
B: wall mounting
D: pendant chain mounting
G: pendant pole mounting
General Catalogue 01.08.2009 http:// www.waromgroup.com
2Emergency Light Fittings
BAY51-Q Series Explosion-proof Emergency Light Fittings for Fluorescent Lamp
2/87
Dimensional drawings
===II 2G Exdeq II CT4
Ex tD A21 IP66 T135�
PCEC (China); LCIE 09 ATEX_____;
PCEC (China)
EN 60079-0:2004; EN 60079-1:2004; EN60079-5:1997;EN 60079-7:2003
IEC 60079-0: 2004; IEC 60079-:2003; IEC 60079-5:1997; IEC 60079-7:2001
IEC 61241-0: 2004 ; IEC 61241-1: 2004
Compression moulding of GRP, stands 7J impact, corrosion protection.
Injection moulding of polycarbonate, 90% light transmission,
Built-in special emergency controller and nickel-cadmium battery pile, has
protection against over charge and over discharge.
Stainless steel
PHILIPS T8(supplied with the light fittings)
36 x 1, 36 x 2
36 x 1
0.3s
24h
90min
AC 220V�240V 50/60Hz
II(Protection against electric shock)
IP66
-20��+55�
Terminal 3 x 1.5�4mm2 (L+N+PE)
4 x ø26, 2 x M25 x 1.5 Cable gland (DQM-I, plastic), 2 x M25 x 1.5 Plug
ø9�ø13 (mm)
BAY51-Q36 x �� J
Selection table
Type/Ordering code
BAY51-Q36 x 1LJ
BAY51-Q36 x 2LJ
BAY51-Q36 x 1XJ
BAY51-Q36 x 2XJ
BAY51-Q36 x 1BJ
Lamp wattage (W)
36 x 1
36 x 2
36 x 1
36 x 2
36 x 1
Weight (kg)
13.65
13.68
13.70
13.75
14.96
Type/Ordering code
BAY51-Q36 x 2BJ
BAY51-Q36 x 1DJ
BAY51-Q36 x 2DJ
BAY51-Q36 x 1GJ
BAY51-Q36 x 2GJ
Lamp wattage (W)
36 x 2
36 x 1
36 x 2
36 x 1
36 x 2
Weight (kg)
15.01
13.57
13.62
15.22
15.25
Explosion-proof emergency light fittings for fluorescent lamp
Technical data
Explosion protection Gas explosion protection
Dust explosion protection
Certificates For gas explosion protection
For dust explosion protection
Conformity to standards
Material Enclosure
Transparent cover
Emergency unit
Exposed fastener
Lamp Lamp
Lamp wattage(W)
Emergency wattage(W)
Emergency start timeCharge timeEmergency lighting timeRated voltageProtection classDegree of protectionAmbient temperatureConnecting terminalCable entriesAvailable cable outer diameter
General Catalogue 01.08.2009 http:// www.waromgroup.com
2 Emergency Light Fittings
BAY51-Q Series Explosion-proof Emergency Light Fittings for Fluorescent Lamp
2/88
Dimensional drawings
===II 2G Exdeq II CT4
Ex tD A21 IP65 T135�
PCEC (China); LCIE 09 ATEX_____;
PCEC (China)
EN 60079-0:2004; EN 60079-1:2004; EN60079-5:1997;EN 60079-7:2003
IEC 60079-0:2004; IEC 60079-1:2004; IEC 60079-5:1997; IEC 60079-7:2001
IEC 61241-0:2004 ; IEC 61241-1:2004
Compression moulding of GRP, stands 7J impact, corrosion protection.
Injection moulding of polycarbonate,90% light transmission,
Built-in special emergency controller and nickel-cadmium battery pile, has
protection against over charge and over discharge.
Stainless steel
PHILIPS T8(supplied with the light fittings)
18 x 1, 18 x 2
18 x 1
0.3s
24h
90min
AC 220V�240V 50/60Hz
II(Protection against electric shock)
IP65
-20��+55�
Terminal 3 x 1.5�4mm2 (L+N+PE)
4 x ø26, 2 x M25 x 1.5 Cable gland (DQM-I, plastic), 2 x M25 x 1.5 Plug
ø9�ø13 (mm)
Explosion-proof emergency light fittings for fluorescent lamp BAY51-Q18 x �� J
Type/Ordering code
BAY51-Q18 x 1LJ
BAY51-Q18 x 2LJ
BAY51-Q18 x 1XJ
BAY51-Q18 x 2XJ
BAY51-Q18 x 1BJ
Lamp wattage (W)
18 x 1
18 x 2
18 x 1
18 x 2
18 x 1
Weight (kg)
8.03
8.08
8.10
8.15
9.35
Type/Ordering code
BAY51-Q18 x 2BJ
BAY51-Q18 x 1DJ
BAY51-Q18 x 2DJ
BAY51-Q18 x 1GJ
BAY51-Q18 x 2GJ
Lamp wattage (W)
18 x 2
18 x 1
18 x 2
18 x 1
18 x 2
Weight (kg)
9.40
7.97
8.02
9.60
9.65
Technical data
Explosion protection Gas explosion protection
Dust explosion protection
Certificates For gas explosion protection For dust explosion protection
Conformity to standards
Material Enclosure Transparent cover
Emergency unit
Exposed fastener
Lamp Lamp Lamp wattage(W)
Emergency wattage(W)
Emergency start timeCharge timeEmergency lighting timeRated voltageProtection classDegree of protectionAmbient temperatureConnecting terminalCable entriesAvailable cable outer diameter
Selection table
General Catalogue 01.08.2009 http:// www.waromgroup.com
2
2/89
Emergency Light Fittings
BAY51-Q Series Explosion-proof Emergency Light Fittings for Fluorescent Lamp
L: pole mounting
2
2
2
2
2
5136017
5136016
51S01G1
51S01G2
5136030
0.136
0.133
0.050
0.130
0.070
450mm
350mm
X: ceiling mounting B: wall mounting
Suitable for ground pole mounting Suitable for fence pole mounting Suitable for wall pole mounting
Qty
Installation accessories and spare parts table
Supplied according to the mounting version
Mounting version
�KSucker
�KChain
�KMounting bracket
�KM8 Screw
�KBracket
Accessories supplied with the light fittings
Remarks: 1. Accessories not in the table should be supplied by user.
2. Quantity of accessories in table is for one set of light fittings.
Weight (kg)Ordering codeRemarkAccessories fittings
D: pendant chain mounting
G: pendant pole mounting
D: pendant chain mounting G: pendant pole mounting
Mounting versions
As a reference to the installation on the site
General Catalogue 01.08.2009 http:// www.waromgroup.com
2
2/90
Emergency Light Fittings
BAY51-Q Series Explosion-proof Emergency Light Fittings for Fluorescent Lamp
Accessories table
�KMounting plate (1)
======�KG1 1/4” Pipe clamp
======�KMounting plate (2)
======�KMounting plate (3)
=====�KWall bracket
2
2
2
2
2
5136012
5136014
5136013
5136015
5136B02
0.060
0.057
0.050
0.201
0.830
L: pole mounting
X: ceiling mounting
B: wall mounting Sheet steel welded
5136003 0.042
5136004 0.024
5118002 0.022
5136005 0.022
5118003 0.014
5136011 1.320
5118004 1.320
Picture Accessories fittings Ordering code Weight (kg)
Installation accessories and spare parts table
Supplied according to the mounting version
Remarks: 1. Accessories not in the table should be supplied by user.
2. Quantity of accessories in table is for one set of light fittings.
Mounting version Accessories supplied with the light fittings
Weight (kg)Ordering codeRemarkQtyAccessories fittings
Explosion-proof travel switch
36W Key
18W Key
36W Lamp holder (with wires)
18W Lamp holder (with wires)
36W Explosion-proof electronic ballast
18W Explosion-proof electronic ballast
General Catalogue 01.08.2009 http:// www.waromgroup.com
2
2/91
Wiring diagram
36W Emergency controller 5136019 1.650
Emergency Light Fittings
BAY51-Q Series Explosion-proof Emergency Light Fittings for Fluorescent Lamp
Normal power
AC220�240V
Charge power
AC220�240V
Note: Control switch K(supplied by user) cann’t control the charge power simultaneously. For
single lamp, no lamp tube 2.
Accessories table
Picture Accessories fittings Ordering code Weight (kg)
Emergency wiring diagram
General Catalogue 01.08.2009 http:// www.waromgroup.com
2
�
�
�
�
�
�
�
BAJ52-20 � Series Explosion-proof Emer-
gency Light Fittings
2/92
Lighting Technology
Zones 1C2X
Explosion protection to
-CENELEC
-IEC
Can be used
in Zone 1 and Zone 2
Enclosure in copper-free aluminium, powder coated, yellow.
Two emergency lamps at upper light fittings, gimbal mount-
ing for versatile lighting angle.
Iodine-tungsten lamp of samll wattage, spotlight, with
reflector, be able to control the lighting angle effectively(LED
lamp is optional).
Maintenance free nickel cadmium battery pile and emergency
unit: automatically charged when normally powered; The
emergency lamp will be turned on automatically when light
off, power off or powr cut. It has various protection against
over charge, over discharge and short circuit.
Toughened glass plate, impact resistance and high light
transmission.
General Catalogue 01.08.2009 http:// www.waromgroup.com
2Emergency Light Fittings
BAJ52 Series Explosion-proof Emergency Light Fittings
2/93
===II 2G Exd II BT4
LCIE 07 ATEX 6086; IECEx CQM 08. 0001;
EN 60079-0: 2004; EN 60079-1: 2004;
IEC 60079-0: 2004; IEC 60079-1: 2003
Copper-free aluminium, powder coated, yellow.
Stainless steel
AC 220V�240V 50Hz
Iodine-tungstem lamp(LED lamp is optional)
2 x 10W ELED lamp wattage�3W x 2F
90min
GNYG5.0 Nickel-cadmium battery pile
5Ah
6V
500mA
1000mA
24h
IP65
-20��+55�
Terminal 3 x 1.5�2.5mm2 (L+N+PE)
2 x G3/4” Plug
Exd Cable gland DQM-II, manufactured by Warom, please see P7/20�23..
5.20kg
Explosion-proof emergency light fittings BAJ52-20
Dimensional drawings
Technical data
Explosion protection
Gas explosion protection
Certificates
For gas explosion protection
Conformity to standards
Material
Enclosure
Exposed fastener
Rated voltage
Lamp
Lamp wattage(W)
Emergency time
Technical data of battery
Description
Rated capacity
Rated voltage
Charge current
Discharge current
Charge time
Protection class
Ambient temperature
Connecting terminal
Cable entries
Cable gland(option)
Weight
General Catalogue 01.08.2009 http:// www.waromgroup.com
2
�
�
�
�
�
�
�
BAYD-�� Series Explosion-proof Emergency
Exit Light Fittings
2/94
�=Sign code type A-G
Type A Type B Type C Type D
Type E Type F Type G
�=Catalogue number logic
=BAYD - �=�
Mounting
Explosion-proof emergency exit light fittings
Sign code: A�G
G: pendant pole mounting
X: ceiling mounting
B: wall mounting
Zones 1C2X 21C22
Explosion protection to
-CENELEC
-IEC
Can be used
in Zone 1 and Zone 2
in Zone 21 and Zone 22
Available for normal lighting and emergency lighting, vari-
ous protections. When normal power fails, it switches to
emergency state automatically, the emergency battery
discharges. Built-in control circuit has various protections
against over charge, over discharge and short circuit, it has
high usability.
With test pushbutton, convenient for user to overhaul termly.
Press down test pushbutton, the light fittings switch to emer-
gency state automatically, the display panel works normally.
If any abnormal found, please maintain it immediately.
LED lamp, high efficient, energy-saving, long service life up
to 5000 hours.
Enclosure in copper-free aluminium, powder coated, yellow.
Toughened glass plate, impact resistance and high light
transmission.
Lighting Technology
General Catalogue 01.08.2009 http:// www.waromgroup.com
2Emergency Light Fittings
BAYD Series Explosion-proof Emergency Exit Light Fittings
2/95
===II 2G Exd II CT6
Ex tD A21 IP65 T85�
LCIE 07 ATEX 6005X; IECEx LCI 08. 0012X
PCEC (China)
EN 60079-0:2004; EN 60079-1:2004; IEC 60079-0:2004 ; IEC 60079-1:2003
IEC 61241-0:2004 ; IEC 61241-1:2004
Copper-free aluminium, powder coated, yellow.
Stainless steel
AC 220V�240V 50Hz
LED lamp(working voltage DC3.6V)
� 2W
90min
600mAh
24h
M5(earthing bolt inside and outside of the light fittings)
IP65
-20��+55�
Terminal 3 x 1.5�2.5mm2(L+N+PE)
1 x G3/4” for wall mounting and ceiling mounting; 2 x M25 x 1.5 for pendant pole
mounting.
1.For wall mounting and ceiling mounting: The light fittings are supplied with cable
gland and lock device. Cable gland is not required for drawing in cables.
2.For pendant pole mounting: The light fittings are supplied with BHD51-F explo-
sion-proof junction box(in copper-free aluminium);
With fittings at cable entries: 2 x M25 x 1.5 plug; Exd Cable gland (option) DQM-II,
manufactured by Warom, please see P7/20�23.
ø10�ø14 (mm)
The light fittings are supplied with installation accessories and spare parts as shown
in mounting versions.
Explosion-proof emergency exit light fittings BAYD- ��
Dimensional drawings
BAYD-X�
BAYD-B�
BAYD-G �
Technical data
Explosion protection Gas explosion protection
Dust explosion protection
Certificates For gas explosion protection
For dust explosion protection
Conformity to standards
Material Enclosure
Exposed fastener
Rated voltageLampPower consumptionEmergency start timeTechnical data of battery Rated capacity
Charge time
Earthing protectionDegree of protectionAmbient temperatureConnecting terminalCable entries
Cable gland
Available cable outer diameterRemarks
General Catalogue 01.08.2009 http:// www.waromgroup.com
2
�
�
�
�
�
BAK51- � / �� Series Tank Inspection Ves-
sel Light Fittings
2/96
�=Catalogue number logic
�=Selection table
BAK51-35/AC220VA
BAK51-35/AC220VB
BAK51-35/DC12VA
BAK51-35/DC12VB
2.00
2.00
1.90
1.90
Type/Ordering code Weight (kg)Available lamp/wattage (W)
BAK51-50/AC220VA
BAK51-50/AC220VB
BAK51-50/DC12VA
BAK51-50/DC12VB
2.00
2.00
1.90
1.90
Type/Ordering code Weight (kg)Available lamp/wattage (W)
Halogen tungsten lamp 35W Halogen tungsten lamp 50W
=BAK51 - �=/ ��
Rated voltage(V)
Rated wattage(W)
Explosion-proof tank inspection vessel light fittings
MountingA: Type A
B: Type B
Zones 1C2
Explosion protection to
-CENELEC
-IEC
Can be used
in Zone 1 and Zone 2
Available for halogen tungsten lamp of 35W and 50W, high
light efficiency, long service life. Assembled with specially
designed reflector, improves spot lighting effect.
A and B mounting versions are available for options.
Enclosure in copper-free aluminium, powder coated, yellow.
Lightiang Technology
General Catalogue 01.08.2009 http:// www.waromgroup.com
2Local, Caution Spotlight Fittings
BAK51 Series Tank Inspection Vessel Light Fittings
2/97
===II 2G Exd II BT3
LCIE 06 ATEX 6020; IECEx LCI 08. 0007;
EN 60079-0:2004; EN 60079-1:2004;
IEC 60079-0:2004; IEC 60079-1:2003
Copper-free aluminium, powder coated, yellow.
Toughened glass cover, impact resistance and high light transmission
Stainless steel
Halogen tungstem lamp
GY6.35
35W, 50W
AC 220V�240V 50Hz
DC12V
M5(earthing bolt inside and outside of the light fittings)
IP65
-20��+55�
Terminal 3 x 1.5�2.5mm2 (L+N+PE)
1 x G3/4”
The light fittings are supplied with cable-clamped seal ring and trumpet shaped gland,
Cable gland is not required for drawing in cables.
ø10�ø14 (mm)
Explosion-proof tank inspection vessel light fittings BAK51- � / ��
A B
Dimensional drawings
Technical data
Explosion protection
Gas explosion protection
Certificates
For gas explosion protection
Conformity to standards
Material
Enclosure
Glass cover
Exposed fastener
Lamp
Available lamp
Lamp holder
Lamp wattage(W)
Adaptable voltage
Earthing protection
Degree of protection
Ambient temperature
Connecting terminal
Cable entries
Cable gland
Available cable outer diameter
General Catalogue 01.08.2009 http:// www.waromgroup.com
2
�
�
�
�
BSZD81-E � Series Explosion-proof Caution
Spotlight Fittings
2/98
�=Catalogue number logic
Lighting Technology
=B S Z D 8 1 - E �
T: lamps in-phase(omissible if none)
LED lamp
Explosion-proof caution spotlight fittings
Zones 1C2
Can be used
in Zone 1 and Zone 2
LED lamp, low power consumption, long service life up to
5000 hours, meeting requirements for energy-saving and en-
vironment protection effectively.
Integrated chip control, with multiple protective circuits, be
able to realize synchronous flash of multiple lamps via syn-
chronous signal wires connection.
Enclosure in copper-free aluminium, powder coated, yellow.
General Catalogue 01.08.2009 http:// www.waromgroup.com
2Local, Caution Spotlight Fittings
BSZD81 Series Explosion-proof Caution Spotlight Fittings
2/99
===II 2G Exde II CT6
NEMKO 08 ATEX 1096;
EN 60079-0:2006; EN 60079-1:2004, EN 60079-7: 2004;
IEC 60079-0: 2004; IEC 60079-1: 2003; IEC 60079-7: 2001;
Copper-free aluminium, powder coated, yellow.
Toughened glass cover, stands 4J impact.
Stainless steel
AC 220V�240V 50/60Hz
LED
� 10W(continuously work)
Red
� 200cd
20�60(time/min)
M5(earthing bolt inside and outside of the light fittings)
IP65
-20��+55�
Terminal 3 x 1.5�2.5mm2 (L+N+PE)
4 x G3/4” Plug
Exe Cable gland DQM-I, manufactured by Warom, please see P7/17�18.
10kg
Explosion-proof caution spotlight fittings BSZD81-E�
Dimensional drawings
Technical data
Explosion protection
Gas explosion protection
Certificates
For gas explosion protection
Conformity to standards
Material
Enclosure
Glass cover
Exposed fastener
Rated voltage
Lamp
Power consumption
Bulb color
Max. luminous intensity value
Flash frequency
Earthing protection
Degree of protection
Ambient temperature
Connecting terminal
Cable entries
Cable gland(option)
Weight
Connection base of lamp 1 Connection base of lamp 2 Connection base of lamp 3
Input power
AC220V�240V 50/60Hz
Unlimited connection
General Catalogue 01.08.2009 http:// www.waromgroup.com
2
�
�
�
�
BSZD81-C � Series Explosion-proof Caution
Spotlight Fittings
2/100
�=Catalogue number logic
=B S Z D 8 1 - C �
T: lamps in-phase(omissible if none)
LED lamp
Explosion-proof caution spotlight fittings
Zones 1C2
Can be used
in Zone 1 and Zone 2
Lamp: 7 sets of halogen tungsten lamp(150W), high light
efficiency. 1 lamp works, others are spare. When the lamp
bulb damaged, spare ones will be used automatically.
Integrated chip control, with multiple protective circuits, be
able to realize synchronous flash of multiple lamps via syn-
chronous signal wires connection.
Enclosure in copper-free aluminium, powder coated, yellow.
Lighting Technology
General Catalogue 01.08.2009 http:// www.waromgroup.com
2
2/101
===II 2G Exde II CT4
PCEC(China)
IEC 60079-0: 2004; IEC 60079-1: 2003; IEC 60079-7: 2001;
Copper-free aluminium, powder coated, yellow.
Toughened glass cover, stands 4J impact.
Stainless steel
AC 220V�240V 50Hz
Halogen tungstem lamp
150W(7 sets of halogen tungsten lamp, 1 lamp works, others are spare. When the
lamp bulb damaged, spare ones will be used automatically.)
Red
� 2000cd
12 time/min generally, nonadjustable
(20�60 time/min if need to adjust, please specify when order)
M5(earthing bolt inside and outside of the light fittings)
IP65
-20��+55�
Terminal 3 x 1.5�2.5mm2 (L+N+PE)
4 x G3/4” Plug
Exe Cable gland DQM-I, manufactured by Warom, please see P7/17�18.
13.8kg
BSZD81-C �
Dimensional drawings
Local, Caution Spotlight Fittings
BSZD81 Series Explosion-proof Caution Spotlight Fittings
Connection base of lamp 1 Connection base of lamp 2 Connection base of lamp 3
Input power
AC220V�240V 50/60Hz
Unlimited connection
Technical data
Explosion-proof caution spotlight fittings
Explosion protection
Gas explosion protection
Certificates
For gas explosion protection
Conformity to standards
Material
Enclosure
Glass cover
Exposed fastener
Rated voltage
Lamp
Lamp wattage
Bulb color
Max. luminous intensity value
Flash frequency
Earthing protection
Degree of protection
Ambient temperature
Connecting terminal
Cable entries
Cable gland(option)
Weight
General Catalogue 01.08.2009 http:// www.waromgroup.com
2BBJ- �� Series Explosion-proof Audio and Vi-
sual Caution Spotlight Fittings
2/102
Type/Ordering code
BBJ-ZR
BBJ-ZB
BBJ-ZY
BBJ-ZG
BBJ-GR
BBJ-GB
BBJ-GY
BBJ-GG
Weight (kg)
2.80
2.80
2.80
2.80
4.50
4.50
4.50
4.50
Remarks: The light fittings are supplied according to ordering code, with accessories and spare parts.
�=Catalogue number logic
�=Selection table
G:pendant pole mounting
Z: horizontal mounting
�
�
�
�
=BBJ - �=�
Explosion-proof audio and visual caution spotlight fittings
Signal color
Mounting
Zones 1C2
Explosion protection to
-CENELEC
-IEC
Can be used
in Zone 1 and Zone 2
LED lamp, low power consumption, long service life.
Enclosure in copper-free aluminium, powder coated, yellow.
Lighting Technology
R: red
B: blue
Y: yellow
G: green
General Catalogue 01.08.2009 http:// www.waromgroup.com
2
2/103
BBJ- ��
BBJ-Z� BBJ-G�
Local, Caution Spotlight Fittings
BBJ Series Explosion-proof Audio and Visual Caution Spotlight Fittings
Technical data
Dimensional drawings
Explosion-proof audio and visual caution spotlight fittingsExplosion protection Gas explosion protectionCertificates For gas explosion protection
Conformity to standards
Material Enclosure Transparent cover
Exposed fastener
Rated voltageSignal colorFlash frequencySound intensityEarthing protectionDegree of protectionAmbient temperatureConnecting terminalCable entriesCable gland
Available cable outer diameterRemarks
===II 2G Exd [ib] ib II CT6
NEMKO 08 ATEX 1095;
EN 60079-0:2006; EN 60079-1:2004; EN 60079-11:2007;
IEC 60079-0: 2004; IEC 60079-1: 2003; IEC 60079-11:1999;
Copper-free aluminium, powder coated, yellow.
Toughened glass cover, impact resistance, high light transmission.
Stainless steel
AC 220V�240V 50/60Hz
Red, blue, yellow and green for options.
150(time/min)
� 80 dB(R=2m)
M5(earthing bolt inside and outside of the light fittings)
IP65
-20��+55�
Terminal 3 x 1.5�2.5mm2 (L+N+PE)
1 x G3/4” for horizontal mounting; 2 x M25 x 1.5 for pendant pole mounting
1.For horizontal mounting: The light fittings are supplied with cable gland and lock
device. Cables can be drew in directly.
2.For pendant pole mounting:
The light fittings are supplied with BHD51-F explosion-proof junction box(in copper-
free aluminium);
With fittings at cable entries: 2 x M25 x 1.5 plug; Exd Cable gland (option)=DQM-II,
manufactured by Warom, please see P7/20�23.
ø10�ø14 (mm)
The light fittings are supplied with installation accessories and spare parts as shown
in mounting versions.
General Catalogue 01.08.2009 http:// www.waromgroup.com
2BJD- �� Series Explosion-proof Caution
Spotlight Fittings
2/104
Type/Ordering code
BJD-ZR
BJD-ZB
BJD-ZY
BJD-ZG
BJD-GR
BJD-GB
BJD-GY
BJD-GG
Weight(kg)
2.70
2.70
2.70
2.70
4.40
4.40
4.40
4.40
Remarks: The light fittings are supplied according to ordering code, with accessories and spare parts.
�=Catalogue number logic
�=Selection table
�
�
�
�
Zones 1C2
=BJD - �=�
Explosion protection to
-CENELEC
-IEC
Can be used
in Zone 1 and Zone 2
LED lamp, low power consumption, long service life.
Enclosure in copper-free aluminium, powder coated, yellow.
G:pendant pole mounting
Z: horizontal mounting
Signal color
Mounting
Explosion-proof caution spotlight fittings
Lighting Technology
R: red
B: blue
Y: yellow
G: green
General Catalogue 01.08.2009 http:// www.waromgroup.com
2Local, Caution Spotlight Fittings
BJD Series Explosion-proof Caution Spotlight Fittings
2/105
===II 2G Exd II CT6
NEMKO 08 ATEX 1091;
EN 60079-0:2006; EN 60079-1:2004
IEC 60079-0: 2004; IEC 60079-1: 2003;;
Copper-free aluminium, powder coated, yellow.
Toughened glass cover, impact resistance, high light transmission.
Stainless steel
AC 220V�240V 50/60Hz
Red, blue, yellow and green for options.
150(time/min)
M5(earthing bolt inside and outside of the light fittings)
IP65
-20��+55�
Terminal 3 x 1.5�2.5mm2 (L+N+PE)
1 x G3/4” for horizontal mounting; 2 x M25 x 1.5 for pendant pole mounting
1.For horizontal mounting: The light fittings are supplied with cable gland and lock
device. Cables can be drew in directly.
2.For pendant pole mounting:
The light fittings are supplied with BHD51-F explosion-proof junction box(in copper-
free aluminium);
With fittings at cable entries: 2 x M25 x 1.5 plug; Exd Cable gland (option)=DQM-II,
manufactured by Warom, please see P7/20�23.
ø10�ø14 (mm)
The light fittings are supplied with installation accessories and spare parts as shown
in mounting versions.
BJD- ��
BJD-Z � BJD-G �
Dimensional drawings
Explosion-proof caution spotlight fittings
Technical data
Explosion protection Gas explosion protection
Certificates For gas explosion protection
Conformity to standards
Material Enclosure
Transparent cover
Exposed fastener
Rated voltageSignal colorFlash frequency
Earthing protectionDegree of protectionAmbient temperatureConnecting terminalCable entriesCable gland
Available cable outer diameterRemarks