lifecore implant
TRANSCRIPT
Lifecore RENOVA™
Internal Hex Implant SystemSurgical & Restorative Catalog
Table of Contents
For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300-2-
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
RENOVA Implant System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5
RENOVA Drill Sequence Charts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7
RENOVA Implants
RENOVA Tapered Implants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
RENOVA Straight Implants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Cover Screws & Healing Abutments . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Cement-Retained Restorations
Cement-on-Crown (COC) Abutment System. . . . . . . . . . . . . . . . . . . . 11-13
Screw-Retained Restorations
UCLA Abutment System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-16
Fixed Detachable Abutment System. . . . . . . . . . . . . . . . . . . . . . . . . . 17-19
Overdenture Restorations
Snap Abutment System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20-22
Surgical Kit for RENOVA Tapered Implants . . . . . . . . . . . . . . . . . . . . . . . . . 23
Surgical Instrumentation for RENOVA Tapered Implants . . . . . . . . . . . . 24-25
Surgical Kit for RENOVA Straight Implants . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Surgical Instrumentation for RENOVA Straight Implants . . . . . . . . . . . . . 27-28
Additional Surgical Instrumentation for Tapered & Straight Implants . . . 29-31
Surgical Wrenches and Drivers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32-33
Lab Tools and Other Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34-35
Lifecore LC5000 Surgical Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36-37
Tissue Regeneration Products
Capset® Calcium Sulfate Bone Graft Barrier. . . . . . . . . . . . . . . . . . . . . . . 38
TefGen® Regenerative Membranes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Warranty Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Order Form . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Introduction
For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -3-
Lifecore Biomedical is dedicated to the development of technologicallyadvanced, dependable products that offer long-term compatibility with thehuman body. Thousands of patients worldwide have benefited from Lifecore’stechnology in dentistry, general surgery and ophthalmology. Founded in 1965,Lifecore is a publicly held company (Nasdaq: LCBM) headquartered in Chaska,Minnesota, USA.
Lifecore’s Oral Restorative Division is focused on providing the highest quality surgical devices and applications for the global dental industry. The Divisionoffers one of the most extensive product lines to address the many clinical situations faced by our clients. Lifecore offers two-stage internal and external hex implant systems and a single stage implant system. A complete family ofrestorative options are available to meet the unique needs of each patient. Visitus at www.lifecore.com to learn more.
Our Commitment to Quality …Lifecore’s commitment to quality and service ensures that our products meet or exceed the highest standards set by the United States Food and DrugAdministration, the European Community and other international agencies.Lifecore has earned ISO 9001 and CE Certifications, international symbols ofquality system assurance and compliance.
Lifecore has earned a reputation for quality by enforcing strict design and inspection criteria. Our 100%inspection of all critical dimensions of dental implantsand prosthetic components has allowed Lifecore tomaintain the tightest tolerances in the industry. Inaddition, Lifecore’s Lifetime Limited Warranty givesthe clinician the added security of knowing that dentalimplants and prosthetics are covered throughout thepatient’s lifetime.
Our Commitment to Your Practice …Lifecore’s technical services department is available to consult with clients on questions related to case planning, component selection and step-by-step procedures for clinical and laboratory applications.
Our family of Support Plus® Restorative Training Programs are recognized in theindustry as the best referral based training courses available. Lifecore is certifiedthrough the Academy of General Dentistry, the American Dental Association andthrough the National Board of Certification to offer continuing education credits.
Lifecore is committed to being the standard of comparison for product quality, education and customer service, and to be recognized as a company of dedication, honesty and integrity.
A Leader in Biotechnology …
RENOVA Implant System
For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300-4-
Internal hex prosthetic connection for superior esthetics and reliability
1mm machined titanium collar for soft tissue maintenance
Parallel walled neck region with circumferential grooves for crestal seal
and bone interlock
Lifecore’s proven RBM Surface
Straight and tapered designs expand treatment options
Tapered design enables placement nearimpinging anatomical structures while
maximizing prosthetic table diameter fornatural emergence profile
Apical end design provides excellent initial thread engagement and stability ST
RAIG
HT
TAPE
RED
For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -5-
Delivers superior strength and easeof prosthetic indexability.
Beveled interface helps maximizeprosthetic stability and evenly transfers occlusal forces to theimplant.
Deep internal hex connectionsimplifies abutment seating andprovides excellent tactile feel foradded confidence.
The Tapered and Straight implant designs share the same prosthetics.
The RENOVA system offers abutment systems for:• Cement-Retained restorations• Screw-Retained restorations• Overdenture restorations
Internal Hex Prosthetic Connection
RENOVA Prosthetics
Lifecore’s RENOVA, RESTORE® and STAGE-1™
implants feature the RBM surface. Lifecore’sRBM, a roughened titanium surface, hasbeen in clinical use since 1997 and hasachieved a high level of clinical acceptance.
Lifecore’s RBM (Resorbable Blast Media) substantially increases bone-to-implant contact and mechanical bone interlock, withapproximately 250% more surface roughness than a machined titanium surface. Safety and biological compatibilityare ensured through the exclusive use ofbiocompatible calcium phosphate ceramicmedia in the roughening process.
As a clinician, you can have confidence in the Lifecore implantyou choose knowing that Lifecore is an established leader in RBMsurface technology. Our three implant designs, coupled with ourRBM surface technology, maximize your opportunity for clinicalflexibility and optimal treatment outcomes.
Proven RBM Surface
2000X RBM Surface
500X RBM Surface
Mechanical interlock of bone into theimplant surface topography is evident. A direct bone-to-implant interface isobserved at 100x magnification.1
References:1. Sanz A, et al. Experimental study of boneresponse to a new surface treatment ofendosseous titanium implants. ImplantDentistry. 2001; 10:126-131.
Drill Sequence RENOVA Tapered Implants
For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300-6-
1 2 3 4 5 62.3mm Round Bur 2.0mm Initial Drill 3.75mm Intermediate Drill 3.75mm Finishing Drill 3.75mm Tap 3.75 x 13mm Implant
1 2 3 4 5 62.3mm Round Bur 2.0mm Initial Drill 4.5mm Intermediate Drill 4.5mm Finishing Drill 4.5mm Tap 4.5 x 13mm Implant
SDI 3.75mm RENOVA Tapered Implant
RDI 4.5mm RENOVA Tapered Implant
Depth Marking System (for Tapered Implants)
13mm
InitialDrill
IntermediateDrill
FinishingDrill
Tap
NOTE: Drill stops and bands referencethe insertion depth for the correspondingimplant length.
0mm≤0.36mm
For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -7-
Drill Sequence RENOVA Straight Implants
Drill
Seq
uenc
e Ch
arts
1 2 3 4 5 7 82.3mm
Round Bur2.0mm
Initial Drill2.35mm
Depth Gauge2.8mm Drill 3.25mm Drill 3.75 x 13mm
Implant3.75mm Tap3.75mm
Countersink Drill
SDI 3.75mm RENOVA Straight Implant
962.35mm
Drill
RDI 4.75mm RENOVA Straight Implant
1 2 3 4 5 8 92.3mm
Round Bur2.0mm
Initial Drill2.35mm
Depth Gauge2.8mmDrill
3.25/4.25mmPilot Drill
4.25mm Drill
4.75mmTap
1072.35mm
Drill4.75 x 13mm
Implant
114.75mm
Countersink Drill
63.25mm
Drill
Depth Marking System (for Straight Implants)
16mm
13mm11.5mm
10mm8mm
0mm≤1.14mm
3.25x16mmDrill
3.25x11.5mmDrill
NOTE: Drill bands reference the insertion depthfor the corresponding implant length and do notindicate actual millimeter drill length.
Lifecore RENOVA Tapered Implants
Features:● Tapered implant design.● Lifecore RBM Surface.● Cover Screw and pre-mounted, color-coded Placement Head (3.5mm) included
with each implant.● Packaged to minimize handling during placement.● Gamma Sterilized.
Instrumentation Required:● RENOVA Tapered Implant Surgical Kit● .048" Hex Driver for Placement Head and Cover Screw
For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300-8-
RENOVA Implants
Description Catalog No.
3.75 x 10mm 140003.75 x 11.5mm 140013.75 x 13mm 140023.75 x 14.5mm 14003
SDI 3.75mm RBM Tapered Implant
Description Catalog No.
4.5 x 8.5mm 140044.5 x 10mm 140054.5 x 11.5mm 140064.5 x 13mm 14007
RDI 4.5mm RBM Tapered Implant
3.75mm
4.5mm
length
length
2.8mmApical
Diameter
3.0mmApical
Diameter
Impl
ants
& He
aling
Abu
tmen
ts
For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -9-
Lifecore RENOVA Straight Implants
Features:● Straight (parallel walled) implant design.● Lifecore RBM Surface.● Cover Screw and pre-mounted, color-coded Placement Head (3.5mm) included
with each implant.● Packaged to minimize handling during placement.● Gamma Sterilized.
Instrumentation Required:❍ RENOVA Straight Implant Surgical Kit❍ .048" Hex Driver for Placement Head and Cover Screw
SDI 3.75mm RBM Straight Implant
RDI 4.75mm RBM Straight Implant
Description Catalog No.
3.75 x 8mm 130003.75 x 10mm 130013.75 x 11.5mm 130023.75 x 13mm 130033.75 x 16mm 13004
Description Catalog No.
4.75 x 8mm 130054.75 x 10mm 130064.75 x 11.5mm 130074.75 x 13mm 130084.75 x 16mm 13009
3.75mm
length
4.75mm
length
Description Catalog No. Catalog No.
Cover Screw 10032 10033
For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300-10-
Cover Screws
Features:● Included with all RENOVA implants.● Offered separately for spare or replacement use.
Instrumentation Required:❍ .048" Hex Driver
SDI 3.75mm RDI 4.5/4.75mm
Healing Abutments
Features:● Healing Abutments are designed to achieve optimal contouring of soft tissue,
which provides for more aesthetic restorations.● Occlusal surface is labeled with the implant prosthetic table (SDI and RDI)
and cuff height.
Instrumentation Required:❍ .048" Hex Driver
Cover Screws & Healing Abutments
Cuff Height Catalog No.
1.5mm 100353mm 100365mm 10037
SDI 3.75mm Healing Abutment
Cuff Height Catalog No.
1.5mm 100383mm 100395mm 10040
RDI 4.5/4.75mm Healing Abutment
For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -11-
Cement-On Crown (COC)Abutment System
Features:● Cement-on Crown (COC) Abutments are intended
for cement-retained restorations where conventional crown and bridge techniques are desired. The COC Abutment can be used for single or multi-unit (splinted) restorations.
● COC Abutments can be prepared as needed and impressioned directly using conventional crown and bridge techniques, eliminating the need for an impression post, analog and other prosthetic components. These abutments may also be used for provisional (temporary) restorations.
Technical Considerations:❍ A minimum inter-occlusal clearance of 4.0mm plus
the additional height of the restoration is required between the implant prosthetic table and the occlusal plane.
❍ It is recommended that bulk abutment reduction be performed outside of the mouth due to risk of heat transfer to the implant.
❍ COC Abutments are made of titanium and are not designed for direct casting to the abutment.
Instrumentation Required:❍ .048" Hex Driver
Torque Recommendation:❍ 30 Ncm for Abutment Screw
Cement-Retained RestorationsLa
bora
tory
Pros
thet
icSu
rger
y
.048” Hex Driver15° Angled
COC Abutment Straight LockingCOC Abutment
Straight LockingCOC Abutment
Straight ImplantTapered Implant
15° AngledCOC Abutment
ImplantAnalog
AbutmentImpressioned Directly
ImplantImpressioned Directly
ImplantImpression Post (Hexed)
Pros
thet
ics
Healing Abutment
For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300-12-
Angled Locking Cement-On Crown (COC) Abutments● For use in single or multi-unit (splinted) restorations where angle
correction is needed.● Pre-machined margins simplify abutment preparation and may be
additionally prepared to follow gingival contours.● COC Abutment may be impressioned directly using conventional crown
and bridge impression techniques. Alternately, a locking implant impression post can be used to impression the implant; allowing the laboratory to prepare the abutment and fabricate the restoration.
● Abutments include .048” hex titanium abutment screw. Additional screws are available separately.
Straight Locking Cement-On Crown (COC) Abutments● For use in single or multi-unit (splinted) restorations.● Abutment margin can be prepared as necessary to follow gingival contours.● COC Abutment may be impressioned directly using conventional crown
and bridge impression techniques. Alternately, a locking implant impression post can be used to impression the Implant; allowing the laboratory to prepare the abutment and fabricate the restoration.
● Abutments include .048” hex titanium abutment screw. Additional screws are available separately.
Description Catalog No. Catalog No.
15°, 2mm Cuff 43094 43096Abutment Screw, Ti 43100 43100
SDI 3.75mm
Description Catalog No. Catalog No.
COC Abutmentwith Screw 43089 43090Abutment Screw, Ti 43092 43092
Cement-Retained Restorations
RDI 4.5/4.75mm
SDI 3.75mm RDI 4.5/4.75mm
For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -13-
Implant Impression Posts (UCLA type)
SDI 3.75mm
● Used for single or multi-unit (splinted) restorations. ● Unique 3-piece design includes a long screw (open tray impressions) and
a short screw (closed tray impressions). ● Transfers soft-tissue contours to the dental laboratory.
Description Catalog No. Catalog No.
ImplantImpression Post 43127 43128
RDI 4.5/4.75mm
Implant Analogs● Replicates the implant for use in the dental laboratory model.● Stainless steel design allows use during soldering procedures.
Description Catalog No. Catalog No.
Implant Analog 43129 43130
SDI 3.75mm RDI 4.5/4.75mm
Pros
thet
ics
For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300-14-
UCLA Abutment SystemFeatures:● The UCLA Abutment System can be used for single or
multi-unit (splinted) crown and bridge restorations. It can also be used for bar attachment retained overdenture restorations.
● UCLA Abutments are used to fabricate highly aesthetic custom restorations that attach directly to the implant.
Technical Considerations:❍ A minimum inter-occlusal clearance of 4.0mm
for the SDI and RDI UCLA Abutments is required between the implant prosthetic table and the top of the abutment screw when seated.
Instrumentation Required:❍ .048” Hex Driver
Torque Recommendation:❍ 30 Ncm for Abutment Screws
Labo
rato
ryPr
osth
etic
Surg
ery
.048” Hex Driver
Straight ImplantTapered Implant
ImplantImpression Post
ImplantImpression Post
ImplantAnalog
Screw-Retained Restorations
Single Unit Restorations
Multi-Unit (Splinted)Restorations
UCLAGold/PlasticSleeve (Non-Locking)
UCLA Gold/PlasticSleeve (Locking)
UCLATemporary
Sleeve(Locking)
UCLATemporarySleeve(Non-Locking)
Healing Abutment
For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -15-
UCLA Gold/Plastic Combo Sleeve● The Gold/Plastic Combo combines the precision fit of a machined
interface with the convenience of a castable plastic chimney.● Specially designed geometry on the plastic chimney improves wax retention.● Offered in both locking and non-locking versions. ● Includes a titanium .048” hex abutment screw.
Description Catalog No. Catalog No.
Locking 43006 43007Non-Locking 43009 43010
SDI 3.75mm
Abutment Screws forUCLA Abutments
● Titanium screw included with each abutment and offered separately.● .048” hex.● Torque recommendation – 30Ncm.
Description Catalog No. Catalog No.
Abutment Screw, Ti 43116 43116
SDI 3.75mm
RDI 4.5/4.75mm
RDI 4.5/4.75mm
Pros
thet
ics
For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300-16-
Implant Analogs● Replicates the implant for use in the dental laboratory model.● Stainless steel design allows use during soldering procedures.
Description Catalog No. Catalog No.
Implant Analog 43129 43130
SDI 3.75mm
Implant Impression Posts (UCLA type)
SDI 3.75mm
● Used for single or multi-unit (splinted) restorations. ● Unique 3-piece design includes a .048” hex long screw (open tray
impressions) and a short screw (closed tray impressions). ● Transfers soft-tissue contours to the dental laboratory.
Description Catalog No. Catalog No.
ImplantImpression Post 43127 43128
RDI 4.5/4.75mm
UCLA Temporary Sleeve● Titanium Temporary Sleeves provide a textured surface for acrylic when
constructing provisional restorations.● Available in non-hexed for multi-unit (splinted) restorations and hexed for
single tooth restorations.● Includes a titanium .048" hex abutment screw.
Description Catalog No. Catalog No.
Sleeve, Hexed 43110 43111Sleeve, Non-Hexed 43113 43114
*Call for availability
SDI 3.75mm*
RDI 4.5/4.75mm
RDI 4.5/4.75mm*
For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -17-
Pros
thet
ics
2-PieceImpression Post
.048" Hex Driver
Coping Screw(.048" Hex)
WaxingPin Fixed
DetachableGold Sleeve
FixedDetachablePlastic Sleeve
Fixed DetachableAbutment Analog
.062" HexDriver
HealingCap
Multi-Unit (Splinted)Restorations
Regular Diameter (RD)components shown
Components not shown to scale.
Fixed Detachable Abutment SystemFeatures:● The Fixed Detachable Abutment System is designed for
multi-unit (splinted) crown and bridge restorations. ● It is also commonly used for bar attachment retained
overdenture restorations. ● The Fixed Detachable Abutment provides excellent
stability and allows for easier path of insertion due to its tapered design.
Technical Considerations:
❍ A minimum inter-occlusal clearance of 6.9mm is required between the implant prosthetic table and the top of the coping screw when seated.
❍ The tapered 12° side wall allows up to 24° of divergence between adjacent abutments.
Instrumentation Required:❍ .062” Hex Driver
Labo
rato
ryPr
osth
etic
Surg
ery
.048" Hex Driver
AC HealingAbutment
1-PieceImpression
Post
FixedDetachable
Abutment
Screw-Retained Restorations
For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300-18-
Screw-Retained Restorations
SDI 3.75mm RDI 4.5/4.75mmDescription Catalog No. Catalog No.
2mm Cuff, .062" Hex 43118 431204mm Cuff, .062" Hex 43119 43121
Fixed Detachable Abutments● Torque recommendation – 30Ncm.
Instrumentation required:● .062" Hex Driver.cuff
SDI 3.75mm RDI 4.5/4.75mmDescription Catalog No Catalog No.
Healing Cap, .048" Hex R2800-00 R2800-00
● Protects the abutment's internal threads and seating surfaceduring healing.
SDI 3.75mm RDI 4.5/4.75mmDescription Catalog No. Catalog No.
1-Piece, 9mm, .048" Hex R9615-48 R9615-482-Piece, 9mm, .048" Hex R9515-48 R9515-48
● 1-piece design is used for closed tray impressions. ● 2-piece design is used for open tray impressions.
Healing Cap for Fixed Detachable Abutments
Impression Posts for Fixed Detachable Abutments
Impression Post, 1-Piece
Impression Post, 2-Piece
For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -19-
Analog for Fixed Detachable Abutments● Replicates the Fixed Detachable Abutment for use by the
dental laboratory.● Stainless steel design allows use during laboratory
soldering procedures.
Description Catalog No. Catalog No.
Fixed Detachable Analog 410530-4 410530-4
Pros
thet
ics
Gold Sleeve and Plastic Sleeve for Fixed Detachable Abutments● Gold Sleeve provides a precision machined interface
between the restoration and the abutment. A Waxing Pin is available for waxing additional vertical height.
● Plastic Sleeve provides an economical alternative to Gold Cylinders and the extended chimney eliminates the need for a Waxing Pin.
● Use with titanium coping screws, which arepurchased separately.
SDI 3.75mm RDI 4.5/4.75mm
Description Catalog No. Catalog No.
Gold Sleeve 410720-4 410720-4Plastic Sleeve, 12mm 410450-4L 410450-4LWaxing Pin R9229-48 R9229-48
SDI 3.75mm
Coping Screw for Fixed Detachable Abutments● Use with Fixed Detachable Abutment Gold and
Plastic Sleeves.● Torque recommendation - 20Ncm.
Description Catalog No. Catalog No.
.048" Hex (1.5mm head) R9490-48 R9460-48
SDI 3.75mm RDI 4.5/4.75mm
RDI 4.5/4.75mm
Gold Sleeve Plastic Sleeve
For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300-20-
Snap Abutment SystemFeatures:● The Snap Abutment System is used with two or more implants for implant attachment retained
overdenture restorations. ● The Snap Abutment threads directly into the implant. ● The Snap Abutment assembly is processed into the denture base either chairside or at the dental laboratory. ● Replacement retention inserts are available in a choice of 8, 10 and 12 Newtons.
Technical Considerations:❍ A minimum inter-occlusal clearance of 7.0mm plus the cuff height is required.❍ Implants must be relatively parallel to one another – less than 20º total divergence.
Overdenture RestorationsLa
bora
tory
Pros
thet
icSu
rger
y
OverdentureAbutment Driver
OverdentureAbutment Driver
.048” Hex Driver
SnapAbutment
SnapAbutment
Straight ImplantTapered Implant
AbutmentAnalog
ImplantAnalog
Snap Abutment Assembly
AbutmentImpressioned Directly
ImplantImpressioned Directly
ImplantImpression Post
Snap Abutment Assembly
Healing Abutment
Instr
umen
tatio
n &
Mot
or
For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -21-
Snap Abutments
Snap Abutment Accessories
● Snap Abutments are packaged with a Snap Abutment Assembly [8 Newtons (N) – yellow] and laboratory spacer.
● Torque Recommendation – 30Ncm.
Instrumentation Required:❍ Overdenture Abutment Driver
Description Catalog No. Catalog No.
1mm Cuff 43102 431062mm Cuff 43103 431073mm Cuff 43104 431084mm Cuff 43105 43109
Description Catalog No.
Abutment Analog L2804-01Snap Retention Inserts, 8N, Qty 6 (includes blue retaining rings) L2806-08Snap Retention Inserts, 10N, Qty. 6 (includes blue retaining rings) L2806-10Snap Retention Inserts, 12N, Qty. 6 (includes blue retaining rings) L2806-12Snap Retention Inserts, Multi-Pack, Qty. 6 (includes blue retaining rings) L2806-13Assembly (8N) with lab spacer L2807-01Seating Tool L2808-01
8 N
RetainingRing
RetentionInsert
RetainingRing
RetentionInsert
RetainingRing
AbutmentAnalog
Snap Abutment
Snap AbutmentAssembly
SeatingTool
RetentionInsert
10 N
12 N
Snap AbutmentAssembly
SDI 3.75mm RDI 4.5/4.75mmcuff
For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300-22-
Implant Analogs● Replicates the implant for use in the dental laboratory model.● Stainless steel design allows use during soldering procedures.
Description Catalog No. Catalog No.
Implant Analog 43129 43130
SDI 3.75mm RDI 4.5/4.75mm
Implant Impression Posts (UCLA type)
SDI 3.75mm
● Used for single or multi-unit (splinted) restorations. ● Unique 3-piece design includes a .048" hex long screw (open tray
impressions) and a short screw (closed tray impressions). ● Transfers soft-tissue contours to the dental laboratory.
Description Catalog No. Catalog No.
ImplantImpression Post 43127 43128
RDI 4.5/4.75mm
For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -23-
Surgical Kit Item List:
The RENOVA Tapered Implant Surgical Kit contains the instrumentation needed to placeRENOVA 3.75 and 4.5mm tapered implants.
2.3mm Round Marking Bur2.0mm Initial Drill3.75 x 10mm Intermediate Drill3.75 x 11.5mm Intermediate Drill3.75 x 13mm Intermediate Drill3.75 x 14.5mm Intermediate Drill3.75 x 10mm Finishing Drill3.75 x 11.5mm Finishing Drill3.75 x 13mm Finishing Drill3.75 x 14.5mm Finishing Drill4.5 x 8.5mm Intermediate Drill4.5 x 10mm Intermediate Drill4.5 x 11.5mm Intermediate Drill4.5 x 13mm Intermediate Drill4.5 x 8.5mm Finishing Drill4.5 x 10mm Finishing Drill4.5 x 11.5mm Finishing Drill4.5 x 13mm Finishing Drill3.75mm Countersink Drill, Tapered4.5mm Countersink Drill, Tapered3.75 x 10mm Surgical Tap
3.75 x 11.5mm Surgical Tap3.75 x 13mm Surgical Tap3.75 x 14.5mm Surgical Tap4.5 x 8.5mm Surgical Tap4.5 x 10mm Surgical Tap4.5 x 11.5mm Surgical Tap4.5 x 13mm Surgical TapSDI 3.5mm NP Placement HeadSDI 5.5mm NP Placement HeadRDI 3.5mm NP Placement HeadRDI 5.5mm NP Placement HeadSDI 15mm NP Placement Head*RDI 15mm NP Placement Head*Locking Drill ExtenderSurgical RatchetStabilizing WrenchHand AdapterRatchet Adapter, 8mmRatchet/Tap Adapter, 12mmHandpiece Adapter.048" Hex Swivel Head Driver, Short
.048" Hex Swivel Head Driver, Long
.048" Hex Driver, Latch-Type, ShortConversion Handle for
Latch-Type InstrumentsRatchet Extender, Short & LongPlacement Head Assembly Sleeves,
SDI & RDIComponent PackGrommet Plugs, 2 Packs of 10Cleaning Detergent
Surgical Kit for RENOVA Tapered Implants
Instr
umen
tatio
n &
Mot
or
* Call for availability
Description Catalog No.
Surgical Kit for Tapered Implants 14012
Kit Features:● Simple step-by-step drill sequences.● RENOVA instrumentation offers improved efficiency,
longevity and overall ease of use. ● Includes drills and taps for use with external irrigation.
For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300-24-
Surgical Instrumentation forRENOVA Tapered Implants
For recommended drill sequences and details on drill depth markings, refer to page 6.
Round Bur & Initial Drill● Round Bur is used for marking the implant site prior to beginning the
drilling sequence.● Initial Drill is the first drill used for all RENOVA Tapered Implants.
Drills for RENOVA Tapered● Specific drill is used for each implant size.● For use with external irrigation.
Description Catalog No.
3.75 x 10mm 140723.75 x 11.5mm 140733.75 x 13mm 140743.75 x 14.5mm 14075
SDI 3.75mm Tapered Intermediate Drills
Description Catalog No.
4.5 x 8.5mm 140804.5 x 10mm 140814.5 x 11.5mm 140824.5 x 13mm 14083
RDI 4.5mm Tapered Intermediate Drills
Description Catalog No.
3.75 x 10mm 140763.75 x 11.5mm 140773.75 x 13mm 140783.75 x 14.5mm 14079
SDI 3.75mm Tapered Finishing Drills
Description Catalog No.
4.5 x 8.5mm 140844.5 x 10mm 140854.5 x 11.5mm 140864.5 x 13mm 14087
RDI 4.5mm Tapered Finishing Drills
Description Catalog No.
Round Marking Bur, 2.3mm L1405-23-002.0mm Initial Drill 14071
Round Bur
Initial Drill
For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -25-
Surgical Taps for RENOVA Tapered Implants
● For pre-tapping bone prior to tapered implant placement. ● Latch-type tap can be used in a handpiece or can be operated manually
when used with the Surgical Ratchet (L1702-01) and Ratchet/Tap Adapter (L1806-05).
Description Catalog No.
3.75 x 10mm 140883.75 x 11.5mm 140893.75 x 13mm 140903.75 x 14.5mm 14091
SDI 3.75mm Tapered Surgical Tap
Description Catalog No.
4.5 x 8.5mm 140924.5 x 10mm 140934.5 x 11.5mm 140944.5 x 13mm 14095
RDI 4.5mm Tapered Surgical Tap
Instr
umen
tatio
n &
Mot
or
For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300-26-
Surgical Kit for RENOVA Straight Implants
Surgical Kit Includes:
Kit Features:● Simple step-by-step drill sequences.● RENOVA instrumentation offers improved efficiency,
longevity and overall ease of use. ● Includes drills and taps for use with external irrigation.
The RENOVA Straight (parallel walled) Implant Surgical Kitcontains the instrumentation needed to place RENOVA 3.75and 4.75mm straight implants.
Description Catalog No.
Surgical Kit for Straight Implants 13010
2.3mm Round Marking Bur2.0mm Initial Drill2.35 x 11.5mm Drill2.35 x 16mm Drill2.8 x 11.5mm Drill2.8 x 16mm Drill3.25 x 11.5mm Drill3.25 x 16mm Drill3.25/4.25mm Pilot Drill4.25 x 11.5mm Drill4.25 x 16mm Drill3.75mm Countersink Drill4.75mm Countersink Drill3.75 x 11.5mm Surgical Tap3.75 x 16mm Surgical Tap4.75 x 11.5mm Surgical Tap4.75 x 16mm Surgical Tap
2.35mm Depth GaugeSDI 3.5mm NP Placement HeadSDI 5.5mm NP Placement HeadRDI 3.5mm NP Placement HeadRDI 5.5mm NP Placement HeadSDI 15mm NP Placement Head*RDI 15mm NP Placement Head*Locking Drill ExtenderSurgical RatchetStabilizing WrenchHand AdapterRatchet Adapter, 8mmRatchet/Tap Adapter, 12mmHandpiece Adapter.048" Hex Swivel Head Driver, Short.048" Hex Swivel Head Driver, Long.048" Hex Driver, Latch-Type, Short
Conversion Handle for Latch-TypeInstruments
Ratchet Extender, Short & LongPlacement Head Assembly Sleeves,
SDI & RDIComponent PackGrommet Plugs, 2 Packs of 10Cleaning Detergent
* Call for availability
For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -27-
For recommended drill sequences and details on drill depth markings, refer to page 7.
Initial Drills
Pilot Drill
Intermediate & Finishing Drills
● Round Bur is used for marking the implant site prior to beginning the drilling sequence.
● Initial Drill is the first drill used for all RENOVA Straight Implants.
Description Catalog No.
2.35 x 11.5mm Drill 130312.35 x 16mm Drill 13032
Description Catalog No.
2.8 x 11.5mm Drill 130332.8 x 16mm Drill 130343.25 x 11.5mm Drill 130353.25 x 16mm Drill 130364.25 x 11.5mm Drill 130384.25 x 16mm Drill 13039
Description Catalog No.
3.25/4.25 Pilot Drill 13037
Description Catalog No.
Round Marking Bur, 2.3mm L1405-23-002.0mm Initial Drill 14071
Drills for RENOVA Straight Implants● For use with external irrigation.● Offered in 2 lengths.
Short – for RENOVA straight implants up to 11.5mmLong – for RENOVA straight implants up to 16mm
● Pilot Drill helps ensure a smooth and accurate transition between the 3.25mm and 4.25mm drills.
● For use with external irrigation.
Description Catalog No.
3.75mm Countersink Drill 130404.75mm Countersink Drill 13041
● Contours ridge prior to placing 3.75mm and 4.75mm RENOVA Straight Implants, allowing implant and cover screw placement at or below the surrounding bone level.
● For use with external irrigation.
Countersink Drills
Surgical Instrumentation for RENOVA Straight Implants
Instr
umen
tatio
n &
Mot
or
Round Bur Initial Drill
Round Bur & Initial Drill
For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300-28-
Surgical Taps for RENOVA Straight Implants
Description Catalog No.
3.75 x 11.5mm Tap 130423.75 x 16mm Tap 13043
● For pre-tapping bone prior to implant placement. ● Latch-type tap can be used in a handpiece or can be operated manually
when used with the Surgical Ratchet (L1702-01) and Ratchet/Tap Adapter (L1806-05).
● For use with external irrigation.● Offered in 2 lengths.
Short – for RENOVA straight implants up to 11.5mmLong – for RENOVA straight implants up to 16mm
SDI 3.75 Straight Surgical Taps
Description Catalog No.
4.75 x 11.5mm Tap 130444.75 x 16mm Tap 13045
RDI 4.75 Straight Surgical Taps
Surgical Instrumentation forRENOVA Straight Implants
For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -29-
Depth Gauge● Verifies depth of the surgical site.● Depth marks correspond to implants lengths.
Description Catalog No.
2.35mm Depth Gauge (for straight implants) 10589
Parallel Pins● Used as a visual guide during surgery to help ensure parallel
implant placement.
Description Catalog No.
2.0mm Parallel Pin (tapered & straight implants), 2-pk 10028*
2.35/2.8mm Parallel Pin (straight implants), 2-pk 13029*
Surgical Ratchet, Adapter and Extenders● Ratchet is used for manual operation of the Surgical
Taps and/or final tightening of the implant.● Ratchet Extenders enable clearance of adjacent teeth.
Description Catalog #
Surgical Ratchet L1702-01
Ratchet Adapter, 8mm L1806-04(for NP Placement Heads)
Ratchet/Tap Adapter, 12mm L1806-05(for NP Placement Heads &Latch-Type Surgical Taps)
Ratchet Extender, Short & Long L1703-01(to extend the RatchetAdapters)
Replacement O-Rings for L1806-03Ratchet Adapter, Qty. 4
Surgical Ratchet
Additional Surgical Instrumentation for Tapered and Straight Implants
Instr
umen
tatio
n &
Mot
or
Narrow Profile (NP)Placement Heads
● Narrow design improves intra-oral access during implant placement.● Color anodized for easy identification of implant/placement head junction.● External flats correspond to the flats of the implants internal hex for
easy indexing.
Instrumentation Required:❍ .048" Hex Driver
Description Catalog No. Catalog No.
3.5mm Placement Head 10585 105875.5mm Placement Head 10586 1058815mm Placement Head 10579* 10580*
SDI 3.75mm RDI 4.5/4.75mm
NP Ratchet Adapters
* Call for availability
Ratchet Extenders
For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300-30-
● Connects to the RENOVA NP Placement Head and carries the implant to the surgical site for hand delivered implant placement.
● Can also be used to remove the placement head by inserting a hex driver through the top end to loosen the screw and then carry the placement head assembly out of the mouth.
Hand Adapter forNarrow Profile (NP)Placement Head
Description Catalog No.
Hand Adapter (for NP placement heads) L1406-02
● Inserts into the handpiece and connects to the RENOVA NP Placement Head for motor driven implant placement.
Handpiece Placement Adapter
Description Catalog No.
Handpiece Adapter (for NP placement heads) L1406-01
● For use only with Narrow Profile (NP) Placement Heads.● Use open or closed end to stabilize the implant during loosening of the
placement head screw.● Features a special pin to engage the Ratchet Adapter (L1806-04) and
stabilize the implant during manual placement.
Stabilizing Wrench
Description Catalog No.
Stabilizing Wrench L1709-01
● Connects directly to RENOVA Tapered and Straight Implant prosthetic connections for adjusting implant insertion depth during first stage surgery.
● Used in conjunction with the Surgical Ratchet.
Direct-to-Implant Ratchet Adapters
Description Catalog No. Catalog No.
Adapter, short 10590 10592Adapter, long 10591 10593
SDI 3.75mm RDI 4.5/4.75mm
For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -31-
Instr
umen
tatio
n &
Mot
or
● Titanium Forceps are used to handle implants and other titanium components to avoid possible contamination.
Titanium Forceps
Description Catalog No.
Titanium Forceps R9119
● Adds 17mm of length to any latch-type drill or driver.● Useful when drilling next to adjacent teeth.
Locking Drill Extender
Description Catalog No.
Locking Drill Extender L1404-01
● Use these transparent overlays with radiographs for pre-surgical assessment and implant selection.
● 100% (1:1) Sizing Overlay for use with peri-apical x-rays.● 125% Sizing Overlay for panoramic radiographs.
Implant Sizing Overlays
Description Catalog No.
Tapered Implant 100% (1:1) Sizing Overlay 14050*Tapered Implant 125% Sizing Overlay 14051*Straight Implant 100% (1:1) Sizing Overlay 13027*Straight Implant 125% Sizing Overlay 13028*
* Call for availability
For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300-32-
Description Catalog No. Accu-Torque Wrench, 20Ncm ISS1101Accu-Torque Wrench, 30Ncm ISS1102
Conversion Handle for Accu-Torque Drivers, Swivel Head ISS1112Replacement O-Rings for Accu-Torque Drivers, Qty 6 ISS1111
Accu-Torque Wrenches & Accessories● Pre-calibrated wrenches precisely deliver proper torque.● Use with Accu-Torque Drivers.● Conversion Handle allows use of Accu-Torque Drivers as hand drivers.
Torque Wrench Care and Maintenance
Cleaning and Sterilization:● Before initial use and after each procedure, clean the torque wrench with a wet towel or disinfectant wipe.
Rinse under warm tap water and wipe dry. ● Before sterilization, spray an approved (handpiece type) instrument lubricant into the opening at the back of
the wrench.● Sterilize with the handle in the broken position.● Wrench may be sterilized by steam autoclave. Do not exceed 125°C (257°F).● Always use the dry cycle. ● Do not use “Flash Sterilization” techniques.● After sterilization, reset the torque break handle, then manually “break” the hinge again to ensure the wrench is
operating correctly.
Calibration:For proper function and accurate control, Accu-Torque Wrenches should be calibrated every 6 months (or after 100 autoclave cycles). For calibration or repair, wrenches should be sent directly to:
Micromotor Repair Station151 East Columbine AvenueSanta Ana, CA 92707 USA800-562-6204Outside the U.S.: 714-546-4045
* For Lifecore’s Torque Wrench warranty information, please reference the Ordering & Warranty Information section on page 37.
Conversion Handle forAccu-Torque Drivers
Wrenches and Drivers
30Ncm Torque Wrench
20Ncm Torque Wrench
For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -33-
Instr
umen
tatio
n &
Mot
or
Description Catalog No. .048" Hex Driver, Swivel Head, Short (8mm shaft/19mm total length) R9121.048" Hex Driver, Swivel Head, Long (13mm shaft/24mm total length) R9122
.048" Hex Driver, Latch-Type, Short (23mm total length) L1400-48-23
.048" Hex Driver, Latch-Type, Long (28mm total length) L1400-48-28
.048" Hex Driver, for Accu-Torque Wrench, Short (8mm shaft) ISS1104
.048" Hex Driver, for Accu-Torque Wrench, Long (15mm shaft) ISS1109
● Use with .048" hex placement head screws, healing abutments, abutment screws and impression posts.
● Tapered hex tip allows screws to be carried to the implant site.
● Used for Fixed Detachable Abutments. ● Tapered hex tip allows abutments to be carried to the implant site.
● Used for Snap Abutments.
Description Catalog No. Overdenture Driver, Swivel Head (8mm shaft) L2100-96-19
Overdenture Driver, Latch-Type (20mm total length) L1404-96-20
Overdenture Driver, for Accu-Torque Wrench* (8mm shaft) L2101-96-16
Description Catalog No. .062" Hex Driver, Swivel Head, Short (8mm shaft/19mm total length) L2100-62-19.062" Hex Driver, Swivel Head, Long (13mm shaft/24mm total length) L2100-62-24
.062" Hex Driver, Latch-Type, Short (23mm total length) L1400-62-19
.062" Hex Driver, Latch-Type, Long (28mm total length) L1400-62-23
.062" Hex Driver, for Accu-Torque Wrench, Short (8mm shaft) ISS1119
.062" Hex Driver, for Accu-Torque Wrench, Long (15mm shaft) ISS1120
.048" Hex Drivers
.062" Hex Drivers
Overdenture Abutment Drivers
Latch TypeDriver
Accu-TorqueDriver
SwivelHeadDriver
LatchType
Driver
Accu-TorqueDriver
SwivelHeadDriver
Latch-Type
Driver
HexDriver
Accu-TorqueDriver
Lab Tools & Other Products
For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300-34-
● A simple, effective bar system, featuring a plastic bar pattern and nylon clips, which are processed into the removable prosthesis.
● Mechanical snap retention.
Hader Bar and Clip System
Description Catalog No. Hader Castable Bar And Clip System ISS185H
(includes 1 Hader Bar, 6Processing Clips, 6 Final Clips & 1 Hader Tool)
Hader Castable Bar ISS185B
Hader Processing Clips, Qty. 6 ISS185HP
Hader Final Clips, Qty. 6 ISS185HR
Hader Clip Metal Housings, Qty. 6 ISS526H
Hader Tool ISS185T
Hader Castable Bar
HaderProcessing Clip
HaderFinal Clip
Hader MetalHousing Clip
Hader Tool
For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -35-
Instr
umen
tatio
n &
Mot
or
Description Catalog No. Component Pack L1812-01
Component Pack ● Organizes small components such as the implant cover screws, placement heads, etc.
● Autoclavable design with slide lid interlocks into the base of the surgical kits.
● Optionally, may be used as a stand-alone organizer.
Instrument Cleaning Detergent• For use with all Lifecore instruments and surgical kits.• Includes recommended cleaning instructions.
Cleaning Detergent L1819-01
For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300-36-
LC5000 Surgical Motor System
Lifecore LC5000 Surgical Motor System PackageDescription Catalog #LC5000 Surgical Motor and Console 1059420:1 Handpiece 1059510-pack of Sterile Irrigation Tubing 10598Testing Gauge for Latch-Type Instrument Shanks 10602PC Software Updating Kit 10611Service Oil, 50ml* 10604
LC5000 Features:Lifecore’s LC5000 is a simple, user-friendly motorwith abundant features forimplantology and oral and maxillofacial microsurgery.Carefully designed features,place the LC5000 in a classof its own. The uniquemotor with large on-screengraphics display, straight-forward console layout, footpedal control andProgram/Patient InformationSmart Cards exemplifieshigh performance.
Since the LC5000 is manufactured specifically for Lifecore Biomedical, it comes complete with Lifecore’ssurgical protocol preprogrammed and is backed by a full one-year warranty. In addition, the compact designhelps maximize surgical work area.
● Compact design helps maximize surgical work area
● Large, easy-to-read display clearly identifies motor settings including procedure, rpm, torque, irrigation flow rate, etc.
● Unique foot pedal design with large buttons simplifies access to functions during surgery. Also provides variable speed control.
● A versatile 20:1 handpiece can be used for drilling, tapping and implant placement (sold separately).
● Torque Bar display provides a visual reference of torque delivered during procedures.
● Program Data Smart Card instantly saves/retrieves up to 20 custom program settings.
● Patient Data Smart Card & PC Software stores patient information for documenting patient treatment data.
● Auto-Calibration function for motor/handpiece enables superior rpm and torque control.
● Full one-year warranty included. Extended warranty options also available. Contact Lifecore Client Service or yoursales representative for more details.
For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -37-
Instr
umen
tatio
n &
Mot
or
Lifecore LC5000 Surgical Motor Accessories Description Catalog #LC5000 Surgical Motor Unit 10594
20:1 Reduction Contra-Angle Handpiece - for implant surgery(up to 150,000 rpm when used with LC5000 Motor) 10595
1:1 High Speed Straight Handpiece (up to 30,000 rpm when used with LC5000 Motor) 10596
1:5 High Speed Straight Handpiece (up to 30,000 rpm when used with LC5000 Motor) 10597
Irrigation Tubing, Sterile, 10-pack 10598
Irrigation Needle, 2-pack 10599
Y-Connector, 2-pack 10600
Y-Tubing, 2-pack 10601
Testing Gauge (for latch-type instrument shanks) 10602
Travel Case (for LC5000 Motor System) 10603
Service Oil, 50ml* 10604
Service Oil, 250ml (6-pack)* 10613
Sterilization Protector for Motor 10607
Sterilization Case 10606
Patient Data Smart Card, 1-pack (for LC5000) 10608
Program Data Smart Card, 1-pack (for LC5000) 10609
System Software Card, 1-pack (for LC5000) 10610
PC Software Updating Kit 10611
USB Cable Adapter 10612
*Due to aerosol service oil can, special shipping and handling is required. Please contact Client Service for shipping rates.
Tissue Regeneration Products
For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300-38-
CAPSET Features:• Bioresorbable• Conforms to Defect• Easy to Use• Positive Tissue Response• Offers Longer Working Time (SlowSet)• Ideal for Multiple Defects (SlowSet)
The 0.25gm reserve cup of calcium sulfate can act as a binder when mixed withBone Allograft, Autogenous Bone, Xenografts or Synthetic Bone grafting material.• Improves handling properties • Reduces particle migration
Description Catalog #CAPSET 1.0gm 4061-10CAPSET 2.0gm 4061-20CAPSET SlowSet 1.0gm 4064-10CAPSET SlowSet 2.0gm 4064-200.25gm Reserve Cup, 6-Pack 4061-025
CAPSET Calcium Sulfate Bone Graft BarrierCAPSET Calcium Sulfate Bone Graft Barrier is a barrier designed to be used over bonegrafting material to aid bone regeneration. Each CAPSET kit contains proprietary formulation calcium sulfate and an accelerating solution. When mixed together, they form a paste, which is molded into place over bone grafting material.
®
For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -39-
Description Catalog #TefGen-FD 25mm x 30mm TFS30TefGen-FD 25mm x 60mm TFR60TefGen-Plus 25mm x 30mm TPS30TefGen-Plus 25mm x 60mm TPR60TefGen-Plus 25mm x 30mm (Interproximal) TPH30TefGen-Plus 18mm x 25mm (U-shape) TPW25TefGen-Plus 10mm x 18mm (Poncho) TPP18
TefGen Regenerative MembranesTefGen Regenerative Membranes are the original non-resorbable, high density PTFEmembranes. They are designed for treatment of periodontal or osseous defectswhere the morphology of the defect creates a protected space, such as an extractionsite, or when bone grafting material is used to create a space underneath the material.
Actual Size
Actual Size
Actual Size
25mm
18m
m
30mm
25m
m
Actual Size
30mm
25m
m
TefGen-FDThe non-expanded structure prevents passage of cells
and bacteria, and allows the material to be easily removed (6,000x).
TefGen-PlusThe porous textured surface of the
membrane at 5,000x.
TPS30TFS30
TPH30
TPW25
TefGen Features: TefGen-FD® TefGen-Plus™
• Biocompatibility ✖ ✖• Ease of placement ✖ ✖• Ease of removal ✖ ✖• Resistant to bacterial colonization ✖ ✖• Increased elasticity ✖• Reduced elasticity ✖• Small pore size facilitates resistance to
bacterial migration through the membrane ✖ ✖• Increased surface area to allow
increased cellular contact ✖• Greater suture pull-out strength ✖
TefGen Membrane Characteristics: TefGen-FD TefGen-Plus• Elasticity Supple Stiffer• Suture pull-out strength Less Resistance Greater Resistance• Surface Smooth Textured• Pore size 0.5-1 microns 0.5-3 microns
25m
m
60mm
Actual Size
18mm
10m
m
TPR60TFR60
TPP18
Tissu
e Re
gene
ratio
nPr
oduc
ts
For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -40-
Warranty InformationOur Client Service Department is open Monday – Thursday 8:00 a.m. – 6:00 p.m., Friday 8:00 a.m. – 5:00 p.m. (central stan-dard time) for Ordering, Technical Support or additional information. Orders may be placed via the internet, phone, fax or mail.Orders placed before 2:00 p.m. will ship the same business day.
www.lifecore.com
Phone: In the United States 800-752-2663 Fax: In the United States 800-651-8521Outside the United States +952-368-4300 Outside the United States +952-368-4324
Mail: Lifecore Biomedical, Inc.Client Service Department3515 Lyman BoulevardChaska, MN 55318-3051 U.S.A.
Non-cash payment may be sent with the order.
Pricing: Prices are subject to change without notice.
Payment Terms and Options: Prepayment for first-time orders may be required. For your convenience, we accept VISA, MasterCard, American Express, Discover and DinersClub. Please remit invoice payments by check to: Lifecore Biomedical, M & I 97, P.O. Box 1150-97, Minneapolis, MN 55480-1150, U.S.A. A $20.00 fee will be applied to your account for anyreturned checks. Lifecore also accepts payments by bank wire transfer. Please contact Lifecore’s Client Service Department for wire transfer instructions.
Shipping Information: Orders shipped within the continental U.S. are normally sent by second day delivery, unless otherwise specified. Please be sure to include a street address.Shipments sent outside the continental U.S. are sent by air courier.
Rush Orders: Overnight delivery services, within the U.S., are available at additional cost. Please contact Lifecore’s Client Service Department for assistance. Additional freight optionsinclude UPS Ground, Second Day Air, Next Day P.M. or Next Day A.M.
Lifetime Warranty: Lifecore offers a Lifetime Warranty on implants and restorative components. For an informational brochure, please contact Lifecore’s Client Service Department.
Medical Device Reporting: If you experience a problem with Lifecore’s product that you believe falls within the scope of the Medical Device Reporting regulations, please contact your local distributor or Lifecore’s Client Service Department immediately for shipping instructions. Product exposed to blood or bodily fluids must be properly labeled for safe handlingby Lifecore personnel.
General Limited Warranty: Lifecore warrants that its products will be free from defects in material and/or workmanship and shall be of merchantable quality. This warrantyapplies only to the original purchaser. In the event of a defect, please notify Lifecore’s Client Service Department of the defect prior to returning product. Lifecore will, at its option, either repair,replace or issue credit for such defects. Lifecore also offers a Lifetime Warranty on implants and restorative components. Lifecore makes no other warranties, express or implied, except as setforth above.
Limitations: Purchaser assumes all risks and liability resulting from the use of these products, whether used separately or in combination with other products not of Lifecore’s manufacture.Lifecore strongly recommends completion of postgraduate dental implant education and strict adherence to the procedures outlined on the instructions for use when they accompany our product.
Lifecore continually strives to improve its products and therefore reserves the right to improve, modify or discontinue products at any time, or to change specifications without notice and without incurring obligations.
Return/Exchange Policy: To return an item, contact your local distributor or call Lifecore’s Client Service Department for an Authorized Returned Goods (ARG) number. No product returns will be accepted without an ARG number. Product returned must be unopened and undamaged, and must be received within 30 days of the invoice date for full refund or credit. Product received within 31-90 days of the invoice date is subject to a 15% restocking fee. No returns over 90 days from invoice date. Product may be exchanged for other Lifecore product of equal or lesser value for 180 days. Individual product packages from Surgical Kits, Quick-Packs or other items sold as sets will not be accepted for return. Cash refunds cannot beissued for returns purchased by credit card. Credit for such returns will be applied to the purchaser’s credit card account.
Driver and Surgical Instrument Warranty: Lifecore recommends that drivers and other instruments be replaced when worn, corroded, dull or otherwise compromised.Lifecore warrants its drivers and other surgical instruments to be free from defects in material and workmanship for six months. If the warrantied driver or instrument fails within the first sixmonths, the purchaser is to notify Lifecore’s Client Service Department prior to returning the product. Lifecore will, at is option, either repair, replace or issue credit for the defective item.Accidental misuse, inappropriate installations or failure to follow manufacturer’s directions voids the warranty. This warranty does not include Surgical Drills and Torque Wrenches as they arecovered under separate warranties.
Surgical Drill Warranty: Lifecore’s Surgical Manual recommends drills be replaced when worn, corroded, dull, or otherwise compromised. Drills should be replaced after 20 to 50uses (depending on bone density), or every six months, whichever comes first. In the event of alleged defect under warranty, the purchaser is to notify Lifecore’s Client Service Departmentpromptly. Client Service will provide instructions for return of the product. Accidental misuse, inappropriate installations or failure to follow manufacturer’s directions voids the warranty.Lifecore warrants the drills against defects in material or workmanship for a period of 90 days from the date of the original invoice. Lifecore’s sole obligation under product warranty is, at its dis-cretion, to replace or repair defective components in part or whole. Drills in use for less than 20 uses and/or six months will be prorated for a replacement discount.
Torque Wrench Warranty: Lifecore warrants the wrench for 90 days to be free of defects in the materials and workmanship. Lifecore’s sole obligation under product warranty is,at its discretion, to repair or replace any defective component or product in part or whole. Accidental misuse, inappropriate installations or failure to follow manufacturer’s care and mainte-nance instructions voids the warranty. In the event of alleged defect under warranty, the purchaser is to notify Lifecore’s Client Service Department promptly. Client Service will provide instruc-tions for return of the product. No product will be accepted at Lifecore without an Authorized Returned Goods number. International clients should contact their local Lifecore representative for warranty claims.
Handpiece Warranty: Lifecore warrants handpieces for one year to be free of defects in the materials and workmanship. Lifecore’s sole obligation under product warranty is, at itsdiscretion, to repair or replace any defective component or product in part or whole. Accidental misuse, inappropriate installations, use of inappropriate lubrication, or failure to follow manufacturer’s care and maintenance instructions voids the warranty. In the event of alleged defect under warranty, the purchaser is to notify Lifecore’s Client Service Department promptly.Client Service will provide instructions for return of the product. No product will be accepted at Lifecore without an Authorized Returned Goods number.
LC5000 Surgical Motor Warranty: Contact Lifecore Client Service for complete details.
When ordering from outside the United States, please contact your local Lifecore Biomedical distributor, or call Lifecoreand ask for an International Client Service Representative.
For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300-41-
MF N30 Before 2 p.m. FS N15
C.O.D. $ After 2 p.m. AP Other
DATEP.O.#
SHIP TO: BILL TO:Name NameAddress AddressCity State Zip City State ZipPhone # Phone #Specialty Credit Card (type)
Card # Exp.Credit Card Billing AddressCity State Zip
❏ Ground ❏ 2nd Day Desired Delivery Date ❏ Next Day ❏ Next Day a.m. Comments❏ COD
O R D E R F O R MTo order by phone call, 800-752-2663 Monday - Thursday between 8 a.m. to 6 p.m., Fridays, 8 a.m. to 5p.m. (Outside the U.S. call 952-368-4300) To order by FAX, call 800-651-8521. (Outside the U.S. call 952-368-4324.) Orders received before 2 p.m. will be shipped the same business day (U.S. only).
Catalog # Qty Description Tax Price Discount Ext. Price
For Office Use
Order # ___________________________________Account # ___________________________________
3515 Lyman Boulevard, Chaska, MN 55318-3051 U.S.A.Phone: 800-752-2663 or 952-368-4300Fax: 800-651-8521 or 952-368-4324
Ord
erin
gIn
form
atio
n
Ord
erin
g In
form
atio
nan
d In
dex
For assistance in the U.S., call 1-800-752-2663, outside the U.S., call 952-368-4300 -42-
INDEX
AAbutments
Cement-On Crown 12Fixed Detachable 18Snap 21
Abutment ScrewsCement-On Crown 12UCLA 15
Accu-Torque Wrenches 32Analogs
Cement-On Crown 13Fixed Detachable 19Snap 22UCLA 16
CCAPSET Calcium Sulfate Bone Graft Barrier 38Cement-On Crown (COC) Abutment System 11-13Cement Retained Restorations 11-13Component Pack 35Coping Screw, Fixed Detachable 19Countersink Drills- RENOVA Straight Implants 27Cover Screws 10
DDepth Gauge 29Drill Sequence Charts 6-7Drills
RENOVA Straight Implants 27RENOVA Tapered Implants 24
Drivers.048" Hex 33.062” Hex 33Overdenture 33
FFinishing Drills
RENOVA Straight Implants 27RENOVA Tapered Implants 24
Fixed Detachable Abutment System 17-19Forceps, Titanium 31
GGold Sleeve, Fixed Detachable 19Gold/Plastic Combo Sleeves, UCLA 15
HHader Bar & Clip System 34Hand Adapter for Placement Head 30Handpiece Placement Adapter 30Healing Abutments 10Healing Cap, Fixed Detachable 18
IImplant Analogs 13, 16, 22Implant Impression Posts
Fixed Detachable 18UCLA Type 13, 16, 22
Implant Sizing Overlays 31Implants
RENOVA Straight 9RENOVA Tapered 8
Impression Posts 13, 16, 18, 22Initial Drills
RENOVA Straight Implants 27RENOVA Tapered Implants 24
Instrument Cleaning Detergent 35Intermediate Drills
RENOVA Straight Implants 27RENOVA Tapered Implants 24
LLC5000 Surgical Motor 36-37Locking Drill Extender 31
MLC5000 Surgical Motor 36-37
NNarrow Profile (NP) Placement Heads 29
OOrder Form 41Overdenture Restorations 20-21
PParallel Pins 29Pilot Drill – RENOVA Straight Implants 27Placement Heads, Narrow Profile (NP) 29Plastic Sleeves
Fixed Detachable 19UCLA 15Gold/Plastic Combo Sleeve, UCLA 15
RRatchet Adapter 29Ratchet Adapter, Direct-to-Implant 30Ratchet Extender 29Ratchet/Tap Adapter 29Retention Inserts, Snap Abutment 21Round Bur 24, 27
RENOVA Straight Implants 27RENOVA Tapered Implants 24
SScrew-Retained Restorations 14-19Seating Tool, Snap Abutment 21Sizing Overlays 31Snap Abutment System 20-22Stabilizing Wrench 30Surgical Kits
RENOVA Straight Implants 26RENOVA Tapered Implants 23
Surgical Motor 36-37Surgical Ratchet 29Surgical Taps
RENOVA Straight Implants 28RENOVA Tapered Implants 25
TTaps, Surgical
RENOVA Straight Implants 28RENOVA Tapered Implants 25
TefGen Regenerative Membranes 39Temporary Sleeve, UCLA 16Tissue Regeneration
CAPSET Calcium Sulfate Bone Graft Barrier 38TefGen Regenerative Membranes 39
Titanium Forceps 31
UUCLA Abutment System 14-16
WWarranty Information 40Waxing Pin, Fixed Detachable 19Wrenches, Accu-Torque 32
Subsidiary:Lifecore Biomedical, AB Särö, Sweden Call: +46-31-93-68-23 Fax:+46-31-93-68-45
Manufacturer:Lifecore Biomedical, Inc.3515 Lyman Blvd.Chaska, MN 55318 USACall: 800-752-2663Fax: 800-651-8521
Outside the USACall: +952-368-4300Fax: +952-368-4324
© Lifecore Biomedical, Inc. 2003 5/04 4410-0119Email: [email protected] www.lifecore.com
Authorized Representative: Lifecore Biomedical, SpAvia A. Fleming, 19 37135 Verona, Italy Call: +39-045-8230294 Fax: +39-045-8250296
Subsidiary:Lifecore Biomedical, GmbHAlfter, GermanyCall: +49-2222-9294-0Fax: +49-2222-977356
Trademark AcknowledgmentsLifecore, Lifecore Biomedical, CAPSET, TefGen and Support Plus are registered trademarks of Lifecore Biomedical, Inc.