SPECIAL FEATURES LIFESPAN INSTALLATION WEIGHT ECO-FRIENDLY INSTALLATION SPACE OPERATING TEMPERATURE Lead Acid LIB 3 ~ 7 years guarantee 15 years guarantee Lead Acid LIB Lead Acid LIB Temp. / Impedance primary sensing capability Analysis / Forecast Protection Capability No hazardous materials used Lead Acid LIB Lead Acid LIB No additional cooling need 20 ~ 25 °C -20 ~ 65 °C 100% 50% -50% 40% -60% 100% LI-ION BATTERY UPS SOLUTION Air conditioning systems account for approximately 40% of a data center’s total energy consumption and the broad oper- ating temperature of Samsung SDI Li-ion battery technology helps reduce operating costs by curbing the use of air condi- tioning in battery rooms. Furthermore, lithium ion batteries offer significant advantages in weight and energy density over lead acid batteries which translates to lower real estate needs and higher white space. Along with Battery Management System, Samsung SDI offers real-time monitoring and control of the system’s functions such as state of charge and health. Mission critical UPS solutions for green data centers, buildings, and plants BMS (Battery Management System)

Upload: hahanh

Post on 31-Mar-2018

218 views

Category:

Documents


3 download

TRANSCRIPT

Special featureS

LIFESPAN INSTALLATION WEIGHT

EcO-FrIENdLy

INSTALLATION SPAcE

OPErATING TEMPErATUrE

Lead Acid LIB

3~7years guarantee

15years guarantee

Lead Acid LIB Lead Acid LIB

Temp. / Impedanceprimary sensing capability

Analysis / Forecast Protection Capability

No hazardous materials used

Lead Acid LIBLead Acid LIB

No additional cooling need

20~25°C -20~65°C

100%

50%

-50% 40%-60%100%

LI-ION BATTEry UPS SOLUTION

Air conditioning systems account for approximately 40% of a data center’s total energy consumption and the broad oper-ating temperature of Samsung SDI Li-ion battery technology helps reduce operating costs by curbing the use of air condi-tioning in battery rooms.

Furthermore, lithium ion batteries offer significant advantages in weight and energy density over lead acid batteries which translates to lower real estate needs and higher white space. Along with Battery Management System, Samsung SDI offers real-time monitoring and control of the system’s functions such as state of charge and health.

Mission critical UPS solutions for green data centers, buildings, and plants

BMS(Battery Management System)

Standard rack Specification

* SDI's LIB system can be easily expanded by adding racks in parallel series* The rack is subject to structural change depending on the UPS specification

Battery ManageMent SySteM

• System voltage, current, SOC, SOH• Cell voltage, current, temperature• Warning / Fault report

• Easy maintenance • Operation cost reduction

rEAL-TIME BATTEry INFOrMATION dIrEcTLy AccESSIBLE By THE USEr

SySteM configuration

cell Module rack System

Prismatic 40Ah / 60Ah 8 cells in series (29.6V) N modules in series N racks in parallel

148Wh / 222Wh 1.2kWh / 1.8kWh ~ 30.8kWh / ~ 46.2kWh > 21.3kWh

[email protected]

SaMSung Sdi co., ltd. 150-20 Gongse-ro, Giheung-gu,Yongin-si, Gyeonggi-do, 446-577, South Korea www.samsungsdi.co.kr

eMail contact

Dealer Information Box

Shelf Type ('15.04 release)

“Lower initial cost”“Less installation space”

capacity kWh 23.1 32.0 35.5

N modules in Series ea 13 18 20

capacity kWh 23.1 32.0 35.5

W mm 600 600 600

L mm 730 730 750

H mm 1,600 2,000 2,350

Weight kg 460 560 650

certificate UL1642 (Cell), UL1973 (Module), UN38.3 (Module), Seismic (Rack), IEC 61000-6-2 / 4 (Rack)