lfl series lf - advantek lightingcatalog number logic catalog logic is for explaining catalog number...
TRANSCRIPT
LF L
LFL SERIESLED Flood Lighting for Wet and Marine Locations
• UL 1598A Marine Outside Type
• UL 1598 Wet Locations
• UL 8750 LED Safety
• CAN/CSA C22.2 No. 250.0-08
• Cast Aluminum
• 65°C Ambient Temperature
• IP66
• NEMA 4X
• Tested to LM79, LM80 Standards
LED Flood Lighting for Wet and Marine LocationsLFL FLOODLIGHT SERIES
RIG-A-LITE
Precision formed specular reflectors for optimum photometric performance.
7H x 6V beam pattern standard.
Cree® XLampXM-L LEDs. 5000K CCT standard. Other CCTs available.
High impact clear glass lens.Polycarbonate lens available as an option.
360° Mounting yoke.
Low copper content aluminum construction (Less than 0.4% copper). Baked-on polyester finish.
Marine grade stainlesssteel hardware.
Safety chain for access cover.
Dual 3/4in. NPT hubs
Optional dark sky visor.
Optional polished stainless steel wire guard.
w w w . r i g a l i t e . c o m
Wet and Marine Locations • Cast Aluminum • UL 1598 • UL 1598A • UL 8750 • CAN/CSA C22.2
LED
LFL Series
Catalog Number Logic
Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts.
BASIC SERIESLFL = Wet Locations/Marine Flood Light UL 1598 Wet Locations UL 1598A Marine Outside Type UL 8750 LED Safety CAN/CSA C22.2 No. 250.0-08 IP66 NEMA 4X
INPUT WATTS 07 = 70W 15 = 130W 20 = 188W
LAMP TYPE L = LED
VOLTAGE/FREQUENCY U = 120 thru 277V 50/60 HZ N = 347/480V 60 HZ 12 = 120V 60 HZ1
22 = 220V 60 HZ1
24 = 240V 60 HZ1
27 = 277V 60 HZ1
34 = 347V 60 HZ1
48 = 480V 60 HZ1
1
2
3
MOUNTING T = Trunnion
BEAM DISTRIBUTION 76 = 7H x 6V
OPTIONS2
EB = Eye Bolt FB1 = Single Fuse Block1,3
FB2 = Double Fuse Block1,3
SP = Surge Protector1
SC = Safety Cable (Eye Bolt Included) PC = Polycarbonate Lens 35 = 3500K CCT 40 = 4000K CCT 56 = 5600K CCT
4
5
6
7
LFL-20-L-U-T-76-XX1 2 3 4 5 76
1 Voltages for fuse block and surge protector.2 Consult factory for pricing.3 Not for Marine application.
Marine grade stainlesssteel hardware.
LED
LFL Series Wet and Marine Locations • Cast Aluminum • UL 1598 • UL 1598A • UL 8750 • CAN/CSA C22.2
RIG-A-LITE
Fixture Wattage Voltage Catalog Numbers Shipping* Weight (Lbs.)
70W 120 thru 277V 50/60HZ LFL-07-L-U-T-76 38
70W 347/480 60HZ LFL-07-L-N-T-76 42
130W 120 thru 277V 50/60HZ LFL-15-L-U-T-76 40
130W 347/480 60HZ LFL-15-L-N-T-76 44
188W 120 thru 277V 50/60HZ LFL-20-L-U-T-76 41
188W 347/480 60HZ LFL-20-L-N-T-76 45
• UL 1598 Wet Locations
• UL 1598A Marine Outside Type
• UL 8750 LED Safety
• Low copper content cast aluminum housing with baked on bronze polyester powder coat finish
• Precision formed specular finished reflector for optimum photometric performance
• Thermal shock, heat and impact-resistant tempered glass lens
• Marine grade stainless steel hardware
• -20° C to 65° C Ambient Temperature
• IP66
• NEMA 4X
• 360° Rotation Mounting Yoke
* For Actual Luminaire Weight, Subtract 3 lbs.
w w w . r i g a l i t e . c o m
Wet and Marine Locations • Cast Aluminum • UL 1598 • UL 1598A • UL 8750 • CAN/CSA C22.2
LED
LFL Series Wet and Marine Locations • Cast Aluminum • UL 1598 • UL 1598A • UL 8750 • CAN/CSA C22.2
Photometric Data
LFL20LUT76XXTotal Lumens 19518.1Input Power
(Watts) 187.52
Efficacy (Lumens/Watt) 104.09
CRI 75.13CCT 5218
LFL15LUT76XXTotal Lumens 13562.18Input Power
(Watts) 129.77
Efficacy (Lumens/Watt) 104.51
CRI 72.6CCT 5088
LFL07LUT76XXTotal Lumens 6918.94Input Power
(Watts) 65.24
Efficacy (Lumens/Watt) 106.05
CRI 71.7CCT 5108
LFL07LUT76 @ 40 Ft High; Tilt Angle = 45°(ISOFOOTCANDLES)
LFL15LUT76 @ 40 Ft High; Tilt Angle = 45°(ISOFOOTCANDLES)
LFL20LUT76 @ 40 Ft High; Tilt Angle = 45°(ISOFOOTCANDLES)
LED
LFL Series Wet and Marine Locations • Cast Aluminum • UL 1598 • UL 1598A • UL 8750 • CAN/CSA C22.2
RIG-A-LITE
Fixture Dimensions (inches)
Accessories
Guard CatalogNumber
86009
Visor CatalogNumber
86036P