Leon Environmental Services Richard “Danny” Leon CAC # 04-3708 Tommy Leon CAC # 05-3882 4545 N. Brawley Ave., Suite 104, Fresno, CA 93722 Phone: 559.274.9200 Fax: 559.274.9240 Email: [email protected] August 27, 2018 Tim Henry North Central Fire District 15850 W. Kearney Blvd. Kerman, CA 93630 Re: Asbestos and Lead Limited Survey Fire Station & Garage 1709 W. Bullard Ave. Fresno, CA Job No. C82-18 Dear Tim: Attached is the Asbestos and Lead Limited Survey Report for the above referenced site. The report includes inspection observations; a list of all samples taken, bulk sample analysis results, and recommendations concerning Asbestos and Lead identified at this site. If you have any questions or need additional information, please do not hesitate to call. Thank you for using Leon Environmental Services. We look forward to working with you in the future. Respectfully yours, Tommy Leon Certified Asbestos Consultant Certification No. 05-3882

Upload: others

Post on 08-Mar-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Leon Environmental Services - North Central Fire · 2018. 8. 27. · Re: Asbestos and Lead LimitedSurvey Fire Station & Garage 1709 W. Bullard Ave. Fresno, CA Job No. C82-18 Dear

Leon Environmental Services Richard “Danny” Leon CAC # 04-3708

Tommy Leon CAC # 05-3882

4545 N. Brawley Ave., Suite 104, Fresno, CA 93722 Phone: 559.274.9200 Fax: 559.274.9240 Email: [email protected]

August 27, 2018 Tim Henry North Central Fire District 15850 W. Kearney Blvd. Kerman, CA 93630 Re: Asbestos and Lead Limited Survey

Fire Station & Garage 1709 W. Bullard Ave. Fresno, CA Job No. C82-18 Dear Tim: Attached is the Asbestos and Lead Limited Survey Report for the above referenced site. The report includes inspection observations; a list of all samples taken, bulk sample analysis results, and recommendations concerning Asbestos and Lead identified at this site. If you have any questions or need additional information, please do not hesitate to call. Thank you for using Leon Environmental Services. We look forward to working with you in the future. Respectfully yours, Tommy Leon Certified Asbestos Consultant Certification No. 05-3882

Page 2: Leon Environmental Services - North Central Fire · 2018. 8. 27. · Re: Asbestos and Lead LimitedSurvey Fire Station & Garage 1709 W. Bullard Ave. Fresno, CA Job No. C82-18 Dear

Leon Environmental Services 4545 N. Brawley Ave., Suite 104, Fresno, CA 93722

Phone: 559.274.9200 Fax: 559.274.9240 Email: [email protected]

ASBESTOS ANALYSIS RESULTS A total of 40 samples of suspect materials were collected by a state certified asbestos inspector from the fire station and garage at 1709 W. Bullard Ave, Fresno, CA. The sample collection areas were determined by the information given to the inspector by Tim Henry of the North Central Fire Protection District about the impending remodel/renovation that is planned for this building. Western Analytical Laboratory, Inc., a NVLAP accredited laboratory performed a total of 52 analyses from 40 samples collected. The chain of custody from Leon Environmental Services and the report from Western Analytical contains a full list of all samples taken from this site.

Sample Location Material % Of ACM

Friable Sq. Ft.

01 Bathroom #1 Floor Red 12x12 Floor Tile >1% No 240’

05 Classroom Floor 9x9 Floor Tile >1% No 1050’

06 Classroom Floor Black Floor Tile Mastic 4-5% No 1660’

09 Conference Room Floor 9x9 Floor Tile >1% No

See Sample

05

10 Conference Room Floor Black Floor Tile Mastic 4-5% No

See Sample

06

14 Bedroom #2 Wall Texture/Paint 0.25% No 4900’

15 Bedroom #2 Wall Joint Compound 0.75% No

See Sample

14

18 Front Room Ceiling Joint Compound 0.75% No

See Sample

14

20 Classroom Ceiling Texture/Paint 0.25% No

See Sample

14

21 Classroom Ceiling Joint Compound 0.75% No

See Sample

14

23 Bedroom #3 Wall Texture/Paint 0.25% No

See Sample

14

24 Bedroom #3 Wall Joint Compound 1-2% No*

See Sample

14

27 Exterior South Window Window Putty 0.75% No 10’

30 Roof Roof Mastic 5% No 10’

33 Garage Wall Joint Compound 1-2% No* 250’

Page 3: Leon Environmental Services - North Central Fire · 2018. 8. 27. · Re: Asbestos and Lead LimitedSurvey Fire Station & Garage 1709 W. Bullard Ave. Fresno, CA Job No. C82-18 Dear

Asbestos and Lead Limited Survey: Fire Station & Garage 1709 W. Bullard Ave, Fresno, CA C82-18

Page 2 of 5

35 Garage Ceiling Joint Compound 1-2% No*

See Sample

35

39 Engine Room Bathroom Floor 12x12 Floor Tile >1% No 40’

* Determined after composite sampling with associated sheetrock

ASBESTOS COMMENTS AND RECOMMENDATIONS

Non-Friable Asbestos

The 12x12 Floor Tile (samples 01, 39) located on the floor of bathroom 1, locker room and the engine room bathroom is positive for asbestos at >1%. The 9x9 Floor Tile (samples 05, 09) located on the floor of the entry, office, classroom, kitchen, bathroom #3 and the conference room is positive for asbestos at >1%. The Black Mastic (sample 06, 10) located on the floor throughout the fire station, except in the engine room, bedroom #1 and bedroom #2 is positive for asbestos at 4-5%. The Texture / Paint (samples 14, 20, 23) located on the walls and ceiling throughout the fire station is positive for asbestos at 0.25%. The Joint Compound (samples 15, 18, 21, 24, 33, 35) located on the walls and ceiling throughout the fire station and garage is positive for asbestos at 1-2%. Please Note: When this material is composited with the associated sheetrock the material contains No Detectable asbestos. The Window Putty (sample 27) on the exterior of the windows of the fire station is positive for asbestos at 0.75%. The Roof Mastic (sample 30) on the roof of the fire station is positive for asbestos at 10%. These materials are considered a non-hazardous non-friable ACM. It is required that a licensed asbestos abatement contractor remove these materials prior to renovation and or demolition of this structure.

ASBESTOS CONCLUSIONS AND REGULATIONS

US EPA NESHAP (40 CFR Part 61) Based on our survey, sampling and subsequent laboratory analysis and regulatory guidelines affecting this site, the types of ACM identified on the previous page require removal (in most cases) prior to demolition and/or renovation procedures to comply with local, state and federal agencies. The US EPA NESHAP (40 CFR Part 61 – November 20, 1990) requires materials containing greater than one percent asbestos be removed prior to renovation or demolition. If those materials are friable or likely to become friable due to the forces expected to act upon them during renovation or demolition, they become a regulated asbestos containing material (RACM) and require a 10-day notification to the local Air Pollution Control District prior to abatement.

Page 4: Leon Environmental Services - North Central Fire · 2018. 8. 27. · Re: Asbestos and Lead LimitedSurvey Fire Station & Garage 1709 W. Bullard Ave. Fresno, CA Job No. C82-18 Dear

Asbestos and Lead Limited Survey: Fire Station & Garage 1709 W. Bullard Ave, Fresno, CA C82-18

Page 3 of 5

CAL OSHA--------Construction Industry--------8CCR, 1529 Cal/OSHA worker health and safety regulations apply during any disturbance of ACM by a person while in the employ of another. This is true regardless of friability or quantity disturbed. If there is greater than 100 square feet of ACM which will be affected by the demolition, a California Licensed Contractor who is registered with Cal/OSHA for asbestos is required. The regulations regarding asbestos are found in Title 8 CCR Section 1529, and also include formal notification requirements to Cal/OSHA at least 24 hours prior to removal. It is required that removal be conducted with the material kept in a wetted state to contain dust and hazardous emissions. The construction industry standard covers employees engaged in demolition and construction, and the following related activities likely to involve asbestos exposure: removal, encapsulation, alteration, repair, maintenance, insulation, spill emergency cleanup, transportation, disposal and storage of ACM. Demolition contractors typically require that a building owner/operator accept responsibility for removal of all ACM found during the building inspection prior to start of demolition activities. Non-friable and non-regulated ACM, in most cases, may be disposed of as construction debris in a landfill that accepts ordinary construction debris. All friable waste containing more than 1% asbestos (RACM) should be manifested as hazardous waste for disposal purposes.

End- of -Section

LEAD BASED PAINT ANALYSIS RESULTS The sample collection areas were determined by the information given to the inspector by Tim Henry of the North Central Fire Protection District about the impending remodel/renovation that is planned for this building. All paint samples were analyzed HUD Guidelines by XRF. The samples listed below are positive for Lead Based Paint (LBP). Sample Sample Location Type Substrate Color XRF Result

(mg/cm²) LBP

84 Station Entry North Door Frame Paint Wood White 1.10 Yes

128 Station Exterior North Window Sash Paint Wood White 1.20 Yes

147 Station Exterior

Porch North Post

Paint Metal White 2.00 Yes

Page 5: Leon Environmental Services - North Central Fire · 2018. 8. 27. · Re: Asbestos and Lead LimitedSurvey Fire Station & Garage 1709 W. Bullard Ave. Fresno, CA Job No. C82-18 Dear

Asbestos and Lead Limited Survey: Fire Station & Garage 1709 W. Bullard Ave, Fresno, CA C82-18

Page 4 of 5

LBP COMMENTS AND RECOMMENDATIONS The White Paint on the wood door frame of the station entryway, the wood window sash on the exterior of the two windows east of the entry door and the metal post on the porch is positive for Lead at > 1.0 mg/cm² level by XRF. Paint samples tested for this survey that were above the 1.0 mg/cm² level by XRF level established by HUD are considered Lead Based Paint (LBP). All homes built prior to 1978 are assumed to contain Lead Based Paint. Lead safe work practices should be in place during all any construction or demolition that would affect these areas. All loose and flaky LBP should be removed prior to demolition or renovation, collected and handled as one waste stream. Based on the levels of LBP identified in the building survey, Leon Environmental recommends that only qualified Lead Abatement Company with properly trained and equipped individuals be used on this project. Procedures and engineering controls must be designed to follow CALOSHA and Department of Health Services (State of California) requirements. The federal and CALOSHA regulations for lead in construction do not specify a level of a lead in paint that classifies it as LBP. However, federal and state OSHA regulations specify airborne lead levels that should not be exceeded during construction without appropriate protection and training. The action level for lead is 30 micrograms per cubic meter of air (µg/m³) and the permissible exposure limit (PEL) is 50µg/m³. These airborne lead levels can be exceeded during construction or demolition activities such as scraping, sanding, grinding, blasting, and torching LBP surfaces, even when levels of lead in paint are far below the HUD definition of LBP of 1.0 mg/cm² or 0.5 percent lead by weight. OSHA Lead in Construction Standard Cal/OSHA 8 CCR 1532.1 shall apply whenever construction work is conducted where employees may be exposed to lead. Beginning April 2010, new federal law (EPA RRP rule) will require that contractors performing renovation, repair and painting projects that disturb lead-based paint in homes, child care facilities and schools built before 1978 that a child under age six visits regularly to be certified and follow specific work practices to prevent lead contamination. Also, beginning April 2010, federal law will require contractors that disturb lead-based paint in homes, child care facilities and schools, built before 1978 to be certified and follow specific work practices to prevent lead contamination.

LBP CONCLUSIONS AND REGULATIONS The Department of Housing and Urban Development (HUD) considers a paint to be a lead-based paint hazard when the content of the paint exceeds 0.5% or 5000ppm. California Occupational Safety and Health (OSHA) regulations require employee personnel monitoring at any detectable levels until statistically reliable results indicate that exposure will remain consistently below the OSHA Action Level of 30

Page 6: Leon Environmental Services - North Central Fire · 2018. 8. 27. · Re: Asbestos and Lead LimitedSurvey Fire Station & Garage 1709 W. Bullard Ave. Fresno, CA Job No. C82-18 Dear

Asbestos and Lead Limited Survey: Fire Station & Garage 1709 W. Bullard Ave, Fresno, CA C82-18

Page 5 of 5

micrograms/m³ and the Permissible Exposure Level of 50 micrograms/m³ for an 8 hour day. The employer must then produce a “Negative Exposure Assessment” to indicate that it is not possible with the specific lead-based paint product to create excessive lead exposure levels.

LIMITATIONS OF LIABILITY Conclusions and recommendations presented in this report are qualitative judgments based on the prevailing regulations and accepted industry standards at the time of the report issuance. Leon Environmental Services provides no other guarantees, either expressed or implied. All quantities of materials listed herein are estimates for sampling purposes only, and should be verified by Owner representative or an abatement / demolition contractor prior to asbestos abatement or demolition. The nature of demolition is such that materials can be uncovered which previously were unknown to exist. Therefore, Leon Environmental Services cannot be responsible for materials not previously detected due to lack of accessibility or concealment, although every effort was made during the inspection to detect all suspect materials. If any suspect materials other than those included herein are discovered during renovation or demolition, it must be assumed that the materials are asbestos containing, and should be treated accordingly until further testing and analysis is performed. The data interpretations and recommendations are based solely on information available to Leon Environmental Services at the time of our inspection. The customer recognizes that site conditions or accessibility may vary, from those encountered at the time of our inspection and sample collection. Varying conditions or access could result in additional information that would lead us to revise conclusions and recommendations. Leon Environmental Services will not be responsible for the interpretation or use by others of information contained within this report. Thomas Leon Date Certified Asbestos Consultant Certification No. 05-3882 State of California Department of Public Health Lead Inspector Assessor # 5157 *Abbreviation Key:

Asbestos Containing Material — ACM (equal to or greater than 0.1% by weight) Vinyl Asbestos Tile – VAT No Asbestos Detected--N.A.D or N.D. Not Sampled—NS

Page 7: Leon Environmental Services - North Central Fire · 2018. 8. 27. · Re: Asbestos and Lead LimitedSurvey Fire Station & Garage 1709 W. Bullard Ave. Fresno, CA Job No. C82-18 Dear

Leon Environmental Services

Richard “Danny” Leon CAC Certification No. 04-3708 Tommy Leon CAC Certification No. 05-3882

4545 N. Brawley Ave., Suite 104, Fresno, CA 93722 Phone: 559.274.9200 Fax: 559.274.9240 Email: [email protected]

Job C82-18 / Sample Location Diagram

Fire Station & Garage – Fire Station / 1709 W. Bullard Avenue, Fresno, CA Tim Henry / Northern California Fire Protection District

Drawing not to Scale

Y = Exterior Samples X = Interior Samples R = Roof Samples

N

X

X

X

X

X

X

X

X

X X

X

Y

R

R

09, 10

20, 21, 22

26

17, 18, 19

03

14, 15, 16

23, 24, 25

07, 08

04, 05, 06

11, 12, 13 01, 02

28, 29

31, 32

27

R 30

Conference Room

Bath #3

Kitchen

Back Porch

Classroom Office

Engine Room

Bath #2

Front Room

Bedroom #1

Bedroom #2

Locker Room

Bath #1 Shower

Flag Pole

X 39,40

Page 8: Leon Environmental Services - North Central Fire · 2018. 8. 27. · Re: Asbestos and Lead LimitedSurvey Fire Station & Garage 1709 W. Bullard Ave. Fresno, CA Job No. C82-18 Dear

Leon Environmental Services

Richard “Danny” Leon CAC Certification No. 04-3708 Tommy Leon CAC Certification No. 05-3882

4545 N. Brawley Ave., Suite 104, Fresno, CA 93722 Phone: 559.274.9200 Fax: 559.274.9240 Email: [email protected]

Job C82-18 / Sample Location Diagram

Fire Station & Garage – Garage / 1709 W. Bullard Avenue, Fresno, CA Tim Henry / Northern California Fire Protection District

Drawing not to Scale

Y = Exterior Samples X = Interior Samples R = Roof Samples

N

X

X

R

33, 34

35, 36

37, 38

Garage

Storage

Page 9: Leon Environmental Services - North Central Fire · 2018. 8. 27. · Re: Asbestos and Lead LimitedSurvey Fire Station & Garage 1709 W. Bullard Ave. Fresno, CA Job No. C82-18 Dear
Page 10: Leon Environmental Services - North Central Fire · 2018. 8. 27. · Re: Asbestos and Lead LimitedSurvey Fire Station & Garage 1709 W. Bullard Ave. Fresno, CA Job No. C82-18 Dear
Page 11: Leon Environmental Services - North Central Fire · 2018. 8. 27. · Re: Asbestos and Lead LimitedSurvey Fire Station & Garage 1709 W. Bullard Ave. Fresno, CA Job No. C82-18 Dear
Page 12: Leon Environmental Services - North Central Fire · 2018. 8. 27. · Re: Asbestos and Lead LimitedSurvey Fire Station & Garage 1709 W. Bullard Ave. Fresno, CA Job No. C82-18 Dear
Page 13: Leon Environmental Services - North Central Fire · 2018. 8. 27. · Re: Asbestos and Lead LimitedSurvey Fire Station & Garage 1709 W. Bullard Ave. Fresno, CA Job No. C82-18 Dear
Page 14: Leon Environmental Services - North Central Fire · 2018. 8. 27. · Re: Asbestos and Lead LimitedSurvey Fire Station & Garage 1709 W. Bullard Ave. Fresno, CA Job No. C82-18 Dear
Page 15: Leon Environmental Services - North Central Fire · 2018. 8. 27. · Re: Asbestos and Lead LimitedSurvey Fire Station & Garage 1709 W. Bullard Ave. Fresno, CA Job No. C82-18 Dear
Page 16: Leon Environmental Services - North Central Fire · 2018. 8. 27. · Re: Asbestos and Lead LimitedSurvey Fire Station & Garage 1709 W. Bullard Ave. Fresno, CA Job No. C82-18 Dear
Page 17: Leon Environmental Services - North Central Fire · 2018. 8. 27. · Re: Asbestos and Lead LimitedSurvey Fire Station & Garage 1709 W. Bullard Ave. Fresno, CA Job No. C82-18 Dear
Page 18: Leon Environmental Services - North Central Fire · 2018. 8. 27. · Re: Asbestos and Lead LimitedSurvey Fire Station & Garage 1709 W. Bullard Ave. Fresno, CA Job No. C82-18 Dear

Leon Environmental ServicesC82-18

Fire Station Garage1709 W. Bullard Ave, Fresno, CA

Lead SamplesXRF Table 1

Reading No Type Units Building Room Side Component Substrate Color Results PbC23 PAINT mg / cm ^2 HOUSE KITCHEN A WALL SHEETROCK WHITE Negative 0.0024 PAINT mg / cm ^2 HOUSE KITCHEN B WALL SHEETROCK WHITE Negative 0.0025 PAINT mg / cm ^2 HOUSE KITCHEN C WALL CMU WHITE Negative 0.0426 PAINT mg / cm ^2 HOUSE KITCHEN D WALL CMU WHITE Null 0.0027 PAINT mg / cm ^2 HOUSE KITCHEN D WALL CMU WHITE Negative 0.0028 PAINT mg / cm ^2 HOUSE BATHROOM A WALL SHEETROCK WHITE Negative 0.1529 PAINT mg / cm ^2 HOUSE BATHROOM B WALL SHEETROCK WHITE Negative 0.0930 PAINT mg / cm ^2 HOUSE BATHROOM C WALL SHEETROCK WHITE Negative 0.0731 PAINT mg / cm ^2 HOUSE BATHROOM D WALL CMU WHITE Negative 0.4032 PAINT mg / cm ^2 HOUSE DEN A WALL CMU WHITE Negative 0.0133 PAINT mg / cm ^2 HOUSE DEN B WALL SHEETROCK WHITE Negative 0.0034 PAINT mg / cm ^2 HOUSE DEN C WALL SHEETROCK WHITE Negative 0.0135 PAINT mg / cm ^2 HOUSE DEN D WALL CMU WHITE Negative 0.0136 PAINT mg / cm ^2 HOUSE LIVING ROOM A WALL CMU WHITE Negative 0.0037 PAINT mg / cm ^2 HOUSE LIVING ROOM B WALL CMU WHITE Negative 0.0138 PAINT mg / cm ^2 HOUSE LIVING ROOM C WALL CMU BLUE Negative 0.0039 PAINT mg / cm ^2 HOUSE LIVING ROOM D WALL SHEETROCK WHITE Negative 0.0040 PAINT mg / cm ^2 HOUSE ENTRY A WALL CMU WHITE Negative 0.1641 PAINT mg / cm ^2 HOUSE ENTRY C WALL CMU WHITE Negative 0.0542 PAINT mg / cm ^2 HOUSE ENTRY D WALL CMU WHITE Negative 0.0443 PAINT mg / cm ^2 HOUSE ENTRY A WALL CMU BEIGE Negative 0.0044 PAINT mg / cm ^2 HOUSE ENTRY B WALL CMU BEIGE Negative 0.0045 PAINT mg / cm ^2 HOUSE ENTRY C WALL CMU BEIGE Negative 0.0146 PAINT mg / cm ^2 HOUSE ENTRY D WALL CMU BEIGE Negative 0.0047 PAINT mg / cm ^2 HOUSE BATHROOM A WALL SHEETROCK WHITE Negative 0.0848 PAINT mg / cm ^2 HOUSE BATHROOM B WALL CMU WHITE Negative 0.0549 PAINT mg / cm ^2 HOUSE BATHROOM C WALL CMU WHITE Negative 0.0250 PAINT mg / cm ^2 HOUSE BATHROOM D WALL SHEETROCK WHITE Negative 0.0651 PAINT mg / cm ^2 HOUSE FRONT ROOM A WALL CMU WHITE Null 0.0352 PAINT mg / cm ^2 HOUSE FRONT ROOM A WALL CMU WHITE Negative 0.0853 PAINT mg / cm ^2 HOUSE FRONT ROOM B WALL SHEETROCK WHITE Negative 0.1154 PAINT mg / cm ^2 HOUSE FRONT ROOM C WALL CMU WHITE Negative 0.0855 PAINT mg / cm ^2 HOUSE FRONT ROOM D WALL CMU WHITE Negative 0.07

Page 19: Leon Environmental Services - North Central Fire · 2018. 8. 27. · Re: Asbestos and Lead LimitedSurvey Fire Station & Garage 1709 W. Bullard Ave. Fresno, CA Job No. C82-18 Dear

Leon Environmental ServicesC82-18

Fire Station Garage1709 W. Bullard Ave, Fresno, CA

Lead SamplesXRF Table 1

56 PAINT mg / cm ^2 HOUSE BEDROOM 1 A WALL CMU WHITE Negative 0.0957 PAINT mg / cm ^2 HOUSE BEDROOM 1 B WALL SHEETROCK WHITE Negative 0.0058 PAINT mg / cm ^2 HOUSE BEDROOM 1 C WALL SHEETROCK WHITE Negative 0.0059 PAINT mg / cm ^2 HOUSE BEDROOM 1 D WALL SHEETROCK WHITE Negative 0.0660 PAINT mg / cm ^2 HOUSE BEDROOM 2 A WALL CMU WHITE Negative 0.0061 PAINT mg / cm ^2 HOUSE BEDROOM 2 B WALL CMU WHITE Negative 0.0262 PAINT mg / cm ^2 HOUSE BEDROOM 2 C WALL SHEETROCK WHITE Negative 0.0063 PAINT mg / cm ^2 HOUSE BEDROOM 2 D WALL SHEETROCK WHITE Negative 0.0064 PAINT mg / cm ^2 HOUSE BATHROOM 2 A WALL SHEETROCK WHITE Negative 0.0565 PAINT mg / cm ^2 HOUSE BATHROOM 2 B WALL CMU WHITE Negative 0.0266 PAINT mg / cm ^2 HOUSE BATHROOM 2 C WALL SHEETROCK WHITE Negative 0.0967 PAINT mg / cm ^2 HOUSE BATHROOM 2 D WALL SHEETROCK WHITE Negative 0.0568 PAINT mg / cm ^2 HOUSE M BATHROOM A WALL SHEETROCK WHITE Negative 0.0069 PAINT mg / cm ^2 HOUSE M BATHROOM B WALL CMU WHITE Negative 0.0070 PAINT mg / cm ^2 HOUSE M BATHROOM C WALL CMU WHITE Negative 0.1671 PAINT mg / cm ^2 HOUSE M BATHROOM D WALL SHEETROCK WHITE Negative 0.0072 PAINT mg / cm ^2 HOUSE HALLWAY A WALL SHEETROCK WHITE Negative 0.0873 PAINT mg / cm ^2 HOUSE HALLWAY B WALL SHEETROCK WHITE Negative 0.2174 PAINT mg / cm ^2 HOUSE HALLWAY D WALL SHEETROCK WHITE Negative 0.2175 PAINT mg / cm ^2 HOUSE KITCHEN B DOOR FRAME WOOD WHITE Negative 0.4076 PAINT mg / cm ^2 HOUSE KITCHEN B DOOR FRAME WOOD WHITE Negative 0.2477 PAINT mg / cm ^2 HOUSE KITCHEN B DOOR TRIM WOOD WHITE Negative 0.3078 PAINT mg / cm ^2 HOUSE KITCHEN B DOOR TRIM WOOD WHITE Negative 0.4079 PAINT mg / cm ^2 HOUSE BATHROOM B DOOR TRIM WOOD WHITE Negative 0.0480 PAINT mg / cm ^2 HOUSE BATHROOM B DOOR FRAME WOOD WHITE Negative 0.1981 PAINT mg / cm ^2 HOUSE DEN B DOOR FRAME WOOD WHITE Negative 0.1782 PAINT mg / cm ^2 HOUSE DEN B DOOR TRIM WOOD WHITE Negative 0.0083 PAINT mg / cm ^2 HOUSE DEN B BASEBOARD WOOD WHITE Negative 0.4084 PAINT mg / cm ^2 HOUSE ENTRY A DOOR FRAME WOOD WHITE Positive 1.1085 PAINT mg / cm ^2 HOUSE ENTRY A DOOR TRIM WOOD WHITE Negative 0.4086 PAINT mg / cm ^2 HOUSE ENTRY B DOOR TRIM WOOD WHITE Negative 0.0087 PAINT mg / cm ^2 HOUSE ENTRY C DOOR TRIM WOOD WHITE Negative 0.5088 PAINT mg / cm ^2 HOUSE ENTRY D DOOR TRIM WOOD WHITE Negative 0.0689 PAINT mg / cm ^2 HOUSE ENTRY B BASEBOARD WOOD WHITE Negative 0.00

Page 20: Leon Environmental Services - North Central Fire · 2018. 8. 27. · Re: Asbestos and Lead LimitedSurvey Fire Station & Garage 1709 W. Bullard Ave. Fresno, CA Job No. C82-18 Dear

Leon Environmental ServicesC82-18

Fire Station Garage1709 W. Bullard Ave, Fresno, CA

Lead SamplesXRF Table 1

90 PAINT mg / cm ^2 HOUSE LIVING ROOM A DOOR FRAME WOOD WHITE Negative 0.6091 PAINT mg / cm ^2 HOUSE LIVING ROOM A DOOR TRIM WOOD WHITE Negative 0.4092 PAINT mg / cm ^2 HOUSE LIVING ROOM B DOOR TRIM METAL WHITE Negative 0.0093 PAINT mg / cm ^2 HOUSE LIVING ROOM B DOOR FRAME METAL BLUE Negative 0.1394 PAINT mg / cm ^2 HOUSE LIVING ROOM B DOOR FRAME METAL BEIGE Negative 0.4095 PAINT mg / cm ^2 HOUSE FRONT ROOM A DOOR FRAME WOOD WHITE Negative 0.6096 PAINT mg / cm ^2 HOUSE FRONT ROOM A DOOR TRIM WOOD WHITE Negative 0.7097 PAINT mg / cm ^2 HOUSE FRONT ROOM D DOOR TRIM METAL WHITE Negative 0.0798 PAINT mg / cm ^2 HOUSE FRONT ROOM D DOOR FRAME METAL WHITE Negative 0.1199 PAINT mg / cm ^2 HOUSE FRONT ROOM D DOOR FRAME METAL BEIGE Negative 0.22

100 PAINT mg / cm ^2 HOUSE FRONT ROOM C DOOR FRAME WOOD WHITE Negative 0.50101 PAINT mg / cm ^2 HOUSE FRONT ROOM C DOOR TRIM WOOD WHITE Negative 0.50102 PAINT mg / cm ^2 HOUSE FRONT ROOM B DOOR FRAME WOOD WHITE Negative 0.70103 PAINT mg / cm ^2 HOUSE BEDROOM 1 C DOOR FRAME WOOD WHITE Negative 0.15104 PAINT mg / cm ^2 HOUSE BEDROOM 1 C DOOR TRIM WOOD WHITE Negative 0.50105 PAINT mg / cm ^2 HOUSE EXTERIOR A WALL CMU TAN Negative 0.11106 PAINT mg / cm ^2 HOUSE EXTERIOR A WALL CMU TAN Negative 0.12107 PAINT mg / cm ^2 HOUSE EXTERIOR B WALL CMU TAN Negative 0.07108 PAINT mg / cm ^2 HOUSE EXTERIOR C WALL CMU TAN Negative 0.10109 PAINT mg / cm ^2 HOUSE EXTERIOR D WALL CMU TAN Negative 0.00110 PAINT mg / cm ^2 HOUSE EXTERIOR A DOOR TRIM METAL WHITE Negative 0.80111 PAINT mg / cm ^2 HOUSE EXTERIOR A DOOR TRIM WOOD WHITE Negative 0.80112 PAINT mg / cm ^2 HOUSE EXTERIOR A DOOR WOOD WHITE Negative 0.00113 PAINT mg / cm ^2 HOUSE EXTERIOR A DOOR WOOD WHITE Negative 0.03114 PAINT mg / cm ^2 HOUSE EXTERIOR A DOOR TRIM WOOD WHITE Negative 0.30115 PAINT mg / cm ^2 HOUSE EXTERIOR C DOOR TRIM WOOD WHITE Negative 0.40116 PAINT mg / cm ^2 HOUSE EXTERIOR C DOOR TRIM WOOD WHITE Negative 0.22117 PAINT mg / cm ^2 HOUSE EXTERIOR C DOOR TRIM WOOD WHITE Negative 0.50118 PAINT mg / cm ^2 HOUSE EXTERIOR C DOOR TRIM WOOD WHITE Negative 0.60119 PAINT mg / cm ^2 HOUSE PORCH C POST WOOD WHITE Negative 0.00120 PAINT mg / cm ^2 HOUSE PORCH C POST WOOD WHITE Negative 0.00121 PAINT mg / cm ^2 HOUSE PORCH C BEAM WOOD WHITE Negative 0.00122 PAINT mg / cm ^2 HOUSE PORCH C FASCIA WOOD WHITE Null 0.60123 PAINT mg / cm ^2 HOUSE PORCH C FASCIA WOOD WHITE Null 0.01

Page 21: Leon Environmental Services - North Central Fire · 2018. 8. 27. · Re: Asbestos and Lead LimitedSurvey Fire Station & Garage 1709 W. Bullard Ave. Fresno, CA Job No. C82-18 Dear

Leon Environmental ServicesC82-18

Fire Station Garage1709 W. Bullard Ave, Fresno, CA

Lead SamplesXRF Table 1

124 PAINT mg / cm ^2 HOUSE PORCH C FASCIA WOOD WHITE Negative 0.00125 PAINT mg / cm ^2 HOUSE PORCH C EAVE WOOD TAN Negative 0.00126 PAINT mg / cm ^2 HOUSE EXTERIOR A WINDOW FRAME METAL WHITE Negative 0.40127 PAINT mg / cm ^2 HOUSE EXTERIOR A WINDOW TRIM WOOD WHITE Null 1.00128 PAINT mg / cm ^2 HOUSE EXTERIOR A WINDOW SASH WOOD WHITE Positive 1.20129 PAINT mg / cm ^2 HOUSE EXTERIOR A WINDOW TRIM WOOD WHITE Negative 0.60130 PAINT mg / cm ^2 HOUSE EXTERIOR A WINDOW FRAME METAL WHITE Negative 0.26131 PAINT mg / cm ^2 HOUSE EXTERIOR A WINDOW FRAME METAL WHITE Negative 0.14132 PAINT mg / cm ^2 HOUSE EXTERIOR A WINDOW FRAME METAL WHITE Negative 0.29133 PAINT mg / cm ^2 HOUSE EXTERIOR A WINDOW FRAME METAL WHITE Negative 0.28134 PAINT mg / cm ^2 HOUSE EXTERIOR A WINDOW FRAME METAL WHITE Negative 0.29135 PAINT mg / cm ^2 HOUSE EXTERIOR B WINDOW FRAME METAL WHITE Negative 0.27136 PAINT mg / cm ^2 HOUSE EXTERIOR C WINDOW FRAME METAL WHITE Negative 0.25137 PAINT mg / cm ^2 HOUSE EXTERIOR C WINDOW FRAME METAL WHITE Negative 0.12138 PAINT mg / cm ^2 HOUSE EXTERIOR C WINDOW FRAME METAL WHITE Negative 0.16139 PAINT mg / cm ^2 HOUSE EXTERIOR C WINDOW FRAME METAL WHITE Negative 0.50140 PAINT mg / cm ^2 HOUSE EXTERIOR C WINDOW FRAME METAL WHITE Negative 0.40141 PAINT mg / cm ^2 HOUSE EXTERIOR C WINDOW FRAME METAL WHITE Negative 0.19142 PAINT mg / cm ^2 HOUSE EXTERIOR C WINDOW FRAME METAL WHITE Negative 0.23143 PAINT mg / cm ^2 HOUSE EXTERIOR D WINDOW FRAME METAL WHITE Negative 0.19144 PAINT mg / cm ^2 HOUSE EXTERIOR D WINDOW FRAME METAL WHITE Negative 0.40145 PAINT mg / cm ^2 HOUSE PORCH A COLUMN WOOD WHITE Negative 0.00146 PAINT mg / cm ^2 HOUSE PORCH A TRIM WOOD WHITE Negative 0.09147 PAINT mg / cm ^2 HOUSE PORCH A POST METAL WHITE Positive 2.00148 PAINT mg / cm ^2 GARAGE CLOSET A WALL SHEETROCK WHITE Negative 0.00149 PAINT mg / cm ^2 GARAGE CLOSET B WALL SHEETROCK WHITE Negative 0.00150 PAINT mg / cm ^2 GARAGE CLOSET C WALL SHEETROCK WHITE Negative 0.00151 PAINT mg / cm ^2 GARAGE CLOSET D WALL SHEETROCK WHITE Negative 0.00152 PAINT mg / cm ^2 GARAGE CLOSET D WINDOW FRAME METAL WHITE Negative 0.02153 PAINT mg / cm ^2 GARAGE CLOSET A DOOR FRAME WOOD WHITE Negative 0.00154 PAINT mg / cm ^2 GARAGE CLOSET A DOOR TRIM WOOD WHITE Negative 0.00155 PAINT mg / cm ^2 GARAGE CLOSET A DOOR WOOD WHITE Negative 0.00156 PAINT mg / cm ^2 GARAGE EXTERIOR A WALL WOOD TAN Negative 0.00157 PAINT mg / cm ^2 GARAGE EXTERIOR B WALL CMU TAN Negative 0.03

Page 22: Leon Environmental Services - North Central Fire · 2018. 8. 27. · Re: Asbestos and Lead LimitedSurvey Fire Station & Garage 1709 W. Bullard Ave. Fresno, CA Job No. C82-18 Dear

Leon Environmental ServicesC82-18

Fire Station Garage1709 W. Bullard Ave, Fresno, CA

Lead SamplesXRF Table 1

158 PAINT mg / cm ^2 GARAGE EXTERIOR C WALL CMU TAN Negative 0.01159 PAINT mg / cm ^2 GARAGE EXTERIOR D WALL CMU TAN Negative 0.03160 PAINT mg / cm ^2 GARAGE EXTERIOR A EAVE WOOD TAN Negative 0.50161 PAINT mg / cm ^2 GARAGE EXTERIOR A COLUMN WOOD TAN Negative 0.30