Consultant: CG2M Studios, LLC 625 E. North Broadway St. Suite 200, Columbus, OH 43214
Phone (614) 436-0100 www.cg2mstudios.com
LensCrafters – Macy’s #8871 North East Mall
Hurst, TX
REVISION #2 Bulletin DATE: 11/13/2017 NATURE OF REVISION: Owner and Architect Comments – all changes clouded G001 -Revision record / drawing index adjusted. AD100 -Note clarification added to plan. AD200 -Coded note #6 adjusted. A101 -Misc. clarification notes added to plan. A103 -New detail call-outs added to plan -Misc. note clarifications A200 -Clarifications made to elevations #8, #9, and #10 A500 -Detail #7, and #8 added to sheet. END OF REVISION
Drawings for:
4000 Luxottica Place Mason, Ohio 45040
VICINITY PLAN
DRAWING INDEX
DRAWING TITLE
ACTIVE
REVISION #
ARCHITECTURAL
G001GENERAL INFORMATION / COVER SHEET
2
-V100 MACY'S FLOOR PLAN
2AD100 EXISTING FLOOR PLAN DEMOLITION
1A100 FIXTURE - FLOOR PLAN
2A101 CONSTRUCTION - FLOOR PLAN
-A102 REFLECTED CEILING PLAN
A103 FINISH PLAN
2A200 INTERIOR ELEVATIONS
1A500 DETAILS
MECHANICAL
-
-
ELECTRICAL
-
-
-
PLUMBING
-
SCOPE OF WORK
THIS PROJECT IS THE TENANT BUILDOUT OF AN EXISTING MERCANTILE SPACE IN AN
EXISTING INTERIOR CENTER AND INCLUDES INTERIOR CONSTRUCTION.
THE SCOPE OF THIS BUILDOUT WILL INCLUDE: (ONLY IN AREA DETAILED ON SHEET
V100)
CONSTRUCTION OF NEW NON LOAD BEARING WALLS
NEW FLOORING FINISHES
NEW CEILING
NEW FURNITURE AND FIXTURES
NEW OD OFFICE EQUIPMENT
NEW SIGNAGE AND GRAPHICS
UTILITY WORK AS REQUIRED TO ACCOMMODATE PROJECT SCOPE
PHONE
CITY
CITY, STATE, ZIP
STREET ADDRESS
CITY OF HURST
1505 PRECINT LINE ROAD
HURST, TX 76054
817-788-7088
DEPARTMENT
BUILDING INSPECTONS
MACY'S KEY PLAN
NEXTORE
6 CREAMERY BROOK
EAST GRANBY, CT 06026
516.393.2484
NEXTORE
4000 LUXOTTICA PLACE
MASON, OH 45040
513.765.6000
DESIGN AND CONSTRUCTION MANAGEMENT
NEXTORE PROJECT MGR.
SCOTT YOUNG
940-445-3122
CONSTRUCTION OF THE NEW LENSCRAFTERS
DEPT. NO CHANGE OF EGRESS OF OR
OCCUPANCY OF THE MACY'S STORE.
SUPL RCV. INSTL EX'G RELO REMARKS
BUILDING PERMIT T GCGC SHALL AMEND / PICK UP PERMIT & PAY ADD'TL FEES; FEES BILLABLE TO NEXTORE AT NET COST; VIA CHANGE ORDER #1
PROFESSIONAL CLEAN-UP, FINAL CLEANINGGC GC
DEMOLITION GC GC FIELD VERIFY EXISTING CONDITIONS AND SEE PLANS FOR SCOPE
TEMPORARY FACILITIES / UTILITIES GC GC GCIF REQUIRED
OTHER PERMITS, FEES, INSURANCEGC GC
INCLUDING ALL LOCAL PEST CONTROL REQUIREMENTS, PERMITS, VERIFY REQUIREMENTS
TEMPORARY BARRICADES (W/ LUX BRAND SPECIFIC LOGO)GC GC
COORDINATE WITH LANDLORD. LOGO SUPPLIED BY TENANT, INSTALLED BY GC
TRASH REMOVAL AND DUMPSTERS GC GC
VERIFY TOWN AND LANDLORD REQUIREMENTS. GC. TO REMOVE/DISPOSE OF ALL BOXES/CRATES/TRASH OF TENANT SUPPLIED AND
INSTALLED ITEMS, INCL. DISPLAY FIXTURES & HARDWARE. DAILY CLEAN REQUIRED.
CUTTING AND PATCHING GC GC GC
SUPL RCV. INSTL EX'G RELO REMARKS
CONCRETE SLAB (NEW OR PATCH FILL)GC GC GC G.C. TO FIELD VERIFY EXIST. COND. TO DETERMINE EXTENTS OF SCOPE. GC TO REPORT TO PROJECT MANAGER.
CUTTING OF EXISTING SLAB-TRENCHING OR CORE DRILLING GC GC GCCOORD. W/ LANDLORD & AFFECTED TENANTS. VERIFY W MACY'S OPERATIONS PRIOR TO ANY CORING OR TRENCHING.
SUPL RCV. INSTL EX'G RELO REMARKS
SUPL RCV. INSTL EX'G RELO REMARKS
BASE BUILDING STRUCTURAL STEEL
STRUCTURAL STEEL AS REQUIRED FOR TENANT BUILD-OUTGC GC GC
METAL FABRICATIONSN/A
EXPANSION JOINTS GC GC GC
SUPL RCV. INSTL EX'G RELO REMARKS
BLOCKING (INCL. FOR FIXTURES, SHELVES, SIGNSGC GC GC FIRE RETARDENT WOOD AND OR METAL PER AUTHORITY JURISDICTION / LL
ROUGH CARPENTRY, FIRE RETARDANT LUMBER & PLYWDGC GC GC
FLOOR PROTECTION (IF REQUIRED)GC GC GC
FINISH CARPENTRY GC GC GC
SUPL RCV. INSTL EX'G RELO REMARKS
SEALANTS, INSULATION, FIRE CAULKING & BLOCKINGGC GC GC SEE SPECIFICATIONS
SPRAYED FIRE RESISTIVE MATERIALS GC GC GC
THROUGH PENETRATIONS FIRE STOP SYSTEM GC GC GC
BATT INSULATION AND/OR SOUND ATTENUATION GC GC GC
SUPL RCV. INSTL EX'G RELO REMARKS
NEW DOORS, FRAMES, HARDWAREGC GC GC
UNLESS NOTED OTHERWISE. (SEE DOOR SCHEDULE SHEET A101)
PANIC / SECURITY ALARMGC GC GC
INTERIOR DOOR LOCK CORES AND KEYS T GC GC
ACCESS DOORS AND FRAMES GC GC GC
MILLWORK MIRRORS T GC GC
SUPL RCV. INSTL EX'G RELO REMARKS
NEW DEMISING PARTITIONS (STUDS & INSTALLATION)GC GC GC SEE PLANS FOR SCOPE OF WORK
NEW DEMISING PARTITIONS (GYPSUM WALLBOARD)GC GC GC
DRYWALL CEILING, WALLS, ENCLOSURES & REQ'D FRAMINGGC GC GC
ACOUSTICAL CEILING 2'x2' TILES & GRID GC GC GC
PAINTING, FINISHING, VARNISH, SEALER, ETC.GC GC GC
FLOOR TRANSITIONS/VINYL TILE / VINYL WALL BASE GC GC GC
CARPET TILE C-63
PORCELAIN FLOOR TILE T GC GC
GROUT AND THINSET FOR TILE & ACCESSORIES GC GC GC
FLOORING TRANSITION STRIPS GC GC GC
WALLCOVERING WC105 GC GC
SUPL RCV. INSTL EX'G RELO REMARKS
ACCESSIBILITY SIGNAGE T GC GC
STORAGE AREA SHELVES & SURFACE MTD. STANDARDS GC GC GC
FIRE EXTINGUISHERS GC GC GCSUGGESTED LOCATION ON PLAN - VERIFY LOCAL REQUIREMENTS
SUPL RCV. INSTL EX'G RELO
REMARKS
MILLWORK (RETAIL)T GC
MILLWORK (O.D.)T
OD EQUIPMENTT T T G.C. TO COORDINATE
POS EQUIPMENTT GC T G.C. TO COORDINATE
MERCHANDISE PROPS T GC GC
FURNITURE (CHAIRS, BENCHES, TABLES, ETC.)T GC GC
STAPLES PURCHASED ITEMS T GC GC
SUPL RCV. INSTL EX'G RELO REMARKS
ACCESS PANELS GC GC GC
ROOF WORK GC GC GCGC TO COORD. W/ LANDLORD WHEN REQUIRED
HVAC DISTRIBUTION, DUCTWORK, DIFFUSERSGC GC GC
PLUMBING FIXTURES GC GCINCLUDING BUT NOT LIMITED TO SINKS, FAUCETS, DRAINS, ETC
T= TENANT
GC= GENERAL CONTRACTOR
LL= LANDLORD
MW= MILLWORKER
N/A= NOT APPLICABLE
NOTE: THE GENERAL CONTRACTOR SHALL VERIFY ALL ITEMS ON THIS SCHEDULE
FOR ACCURACY PRIOR TO BEGINNING CONSTRUCTION. ANY DISCREPANCIES
SHALL BE REPORTED TO LUXOTTICA PROJECT MANAGER IMMEDIATELY.
DIVISION 01000 - GENERAL
DIVISION 03000 - CONCRETE
DIVISION 04000 - MASONRY
DIVISION 05000 - MISC. METALS
DIVISION 06000 - WOOD & PLASTICS
DIVISION 07000 - THERMAL & MOISTURE PROTECTION
DIVISION 08000 DOORS & WINDOWS
DIVISION 09000 - FINISHES
DIVISION 10000 - SPECIALTIES
DIVISION 12000 - FURNISHINGS
DIVISION 15000 - MECHANICAL
GC GC
FLOOR DRAINS / PIPING / SUPPORTSGC GC GC
WATER AND SEWER CONNECTION GC GC GC GC
SPRINKLER SYSTEM MODIFICATIONS GC GC GC GCBY L.L. DESIGNATED CONTRACTOR AT G.C. EXPENSE. GC RESP. FOR MODIFICATIONS, DRAWINGS, AND APPROVALS.
WATERPROOF MEMBRANE GC GC GC
IF EGRESS DOOR REQUIRED
PORCELAIN WALL TILE T GC GC
GLAZING FILM - EXTERIOR GRAPHICS T T T
T
GC T
LENS PROCESS EQUIPMENTT T T
SANITARY PUMP (ALL COMPONENTS)GC GC GC
GC GC GC
INSTA-HOT WATER HEATERS
DOCTOR'S CERTIFICATES / LICENSES T GC GC
CUSTOM WOOD MILLWORK WD201 T GC T
(2) CLEANINGS REQUIRED. (1) PRIOR TO PUNCH & (1) AT TURNOVER
RELOCATION OF EXISTING MACY'S FIXTURES LL LLGC TO VERIFY UPON ARRIVAL ON JOB SITE THAT THE SITE HAS BEEN CLEARED OF ALL MAC'Y FIXTURES IN ORDER TO PERMORM AREA
CONSTRUCTION. NOTIFY NEXTORE PROJECT MANAGER OF ANY QUESTIONABLE ITEMS EXISTING.
DURABLE PROTECTION REQUIRED. PROVIDE WALK-OFF MAT AT BOTH SIDE OF ENTRY POINT(S) OF CONSTRUCTION AREA
IF REQUIRED BY LL
EXTENT OF WATERPROOF MEMBRANE SHALL BE VERIFIED W LL BY THE GC
3/4" X 3/4" WOOD TRIM
WOOD TRIM (OPEN DOOR SURROUND)
SEE PLANS FOR SCOPE OF WORK.
PER USG AESTHETIC ASSEMBLIES, ALL WALLS (INCLUDING EXISTING TO REMAIN), SHALL RECEIVE "LEVEL 4" FINISH, & CEIL "LEVEL 5"
SANITARY BOOSTER
GC GC GC
GC MUST INSTALL FLOOR PER FLOORING MFG SPECS.
GC GC GC
GC GC GC
GC GC GCWOOD BASEBOARD WB101 & WB102
SUPL RCV. INSTL EX'G RELO REMARKS
CONNECTION AND WIRING @ MILLWORK THROUGHOUT GC GC GC
ELECTRICAL SERVICE CONDUIT ONLY GC GC GC
ELECTRICAL PANELS / TRANSFORMERS GC GC GC
ELECTRICAL WIRING, CIRCUITING, RECEPTACLES, SWITCHESGC GC GC
RECEPTACLES IN MILLWORK(WIRING AND FINAL CONNECTIONS BY GC)
EMERGENCY LIGHTING T GC GC
EXIT SIGNS T GC GC
FIRE ALARM SYSTEM LL LL LL
NEW LIGHT FIXTURES & LAMPS T GC GC
REPLACEMENT OR MATCHING EXISTING LIGHT FIXTURES & LAMPS GC GC GC
SOUND SYSTEM SPEAKERS GC TO RELOCATE WHEN APPLICABLE / MATCH EXIST. WIRE AND EXTEND
TELEPHONE CONDUIT TO SPACE
TELEPHONE WIRING TO SPACE
TENANT TELEPHONE EQUIPMENTT T T G.C. TO COORDINATE
TELEPHONE WIRING
CONDUITS - DATA, COMMUNICATION, ALARMS, PHONESGC GC GC TENANT'S LOW VOLTAGE VENDOR PERFORMS DATA TERMINATIONS
POS AND DATA WIRING
WIRELESS EQUIPMENTT T T
JACK TERMINATION & FACEPLATE - DATA
MACY'S BACKBOARD TERMINATION - DATA T T
JACK TERMINATION & FACEPLATE - PHONE
MACY'S BACKBOARD TERMINATION - PHONE T T
SECURITY - FACILITY (HARDWARE & WIRING)GC GC GC
COORDINATE WITH TRADES FOR SIZE AND LOCATION.
DIVISION 16000 - ELECTRICAL
ALL MILLWORK LIGHTING IS PLUG & PLAY
T T T
WIRING TO BE PLENUM RATED
T T T
VINYL BASE @ ROUND COLUMNS
PAINTED P104
GC
GC SHALL PROVIDE ALTERNATE PRICE - SEE ELECTRICAL SHEETS. WIRING TO BE PLENUM RATED
SEE PLUMBING DRAWINGS FOR SCOPE OF WORK
GC SHALL PROVIDE ALTERNATE PRICE - SEE ELECTRICAL SHEETS.
GC SHALL PROVIDE ALTERNATE PRICE - SEE ELECTRICAL SHEETS.
GC SHALL PURCHASE PUMP FROM NEXTORE'S REQUIRED VENDOR. SEE PLUMBING SHEETS FOR CONTACT INFORMATION.
GC TO REFER TO ELECTRICAL RISER DIAGRAM
T T T
T
T
RECEIVED & OFFLOADED BY G.C. / UNCRATED & INSTALLED BY TENANT. CONSULT NEXTORE PM FOR POSSIBLE INSTALLATION REQ.
T
WIRING TO BE PLENUM RATED
COORDINATE W/ LL & NEXTORE PM
ASSET PROTECTION COORDINATION GCIF OVERNIGHTS REQUIRED, GC SHALL PAY AP VENDOR & COORDINATE OVERNIGHT POWER W OPS MANAGER.
INSURANCE
JURISDICTION
GC TO ADD MACYS AS AN ADDITIONALLY INSURED PARTY ON CERTIFICATE OF LIABILITY INSURANCE. CERTIFICATES NEED TO BE SENT
TO THE NEXTORE PROJECT MANAGER. NEXTORE PROJECT MANAGER TO FORWARD TO THE MACY'S PROJECT MANAGER.
GC MUST INSTALL FLOOR PER FLOORING MFG SPECS. REFER TO FINISH SCHEDULE SHEET A103.
T T T
T T T
T T T
RECEIVED & OFFLOADED BY G.C. / UNCRATED & INSTALLED BY TENANT. CONSULT NEXTORE PM FOR POSSIBLE INSTALLATION REQ.
T
CARPET (OTHER THAN C-63)GC GC GC
GC MUST INSTALL FLOOR PER FLOORING MFG SPECS. REFER TO FINISH SCHEDULE SHEET A103.
T
WALLCOVERING WC106 GC GC GC
PROJECT DIRECTORY
MPE100 OVERALL EXISTING FLOOR PLANS
H200
E100
P200
HVAC PLAN
SPECIFICATION, SYMBOLS AND DEMOLITION
SANITARY AND VENT PLANS AND DETAILS
GC TO OBTAIN
E200 POWER AND LOW VOLTAGE PLANS
E300
NEXTORE STORE DESIGNER
CASSANDRA HANLIN
513-765-3766
DETAIL & RISER
RESPONSIBILITY SCHEDULE
LENSCRAFTERS / MACYS CONSTRUCTION CRITERIA REV0.0
JOB SITE ADDRESS
PHONE
LANDLORD
CITY, STATE, ZIP
STREET ADDRESS
7 WEST 7TH STREET
CINCINNATI, OH 45202
646-429-7278
CONST. COORDINATOR
NATASHA DYCE
MACY'S CORPORATE SERVICES
PHONE
CITY, STATE, ZIP
STREET ADDRESS
STORE CONTACT
MACYS PROJECT MANAGER: DAVID DARLINGTON
NAME
HURST, TX 76053
-
1101 MELBOURNE ROAD, SUITE 3000
MACY'S
SPACE NUMBER
CITY, STATE, ZIP
STREET ADDRESS
LANDLORD'S ADDRESS
MACY'S STORE INFO.
CODE INFORMATION
COMMENTS
1
2 3 4 5
6 7
8 9 10
11 12
GC GC GC GC TO PROVIDE ALL NECESSARY CONSTRUCTION & MATERIAL TO COMPLETE EXTERIOR SIDEWALK WHEN APPLICABLE.SIDEWALK AT EXTERIOR DOOR
GC GC GC GC TO PROVIDE ALL NECESSARY CONSTRUCTION & MATERIAL TO COMPLETE EXTERIOR ENTRY WAY WHEN APPLICABLE.NEW ENTRY OPENING
GC GC GCCHAIR RAIL
RETAIL WALL SIGNAGE T GC GC
GRAPHIC HOLDER T GC GC SEE FIXTURE PLAN & ELEVATION SHEETS FOR MORE INFORMATION
GRAPHICS T GC GC
T T T
LOCATION OF PROPOSEDNEW LENS CRAFTERS PAD
NORTH
NORTH EAST MALL
HURST, TX
1-LCM17-G001-REV00
2-LCM17-G001-REV00 3-LCM17-G001-REV00
6-LCM17-G001-REV00 7-LCM17-G001-REV00 4-LCM17-G001-REV00 5-LCM17-G001-REV00
8-LCM17-G001-REV00
9-LCM17-G001-REV00 10-LCM17-G001-REV00
11-LCM17-G001-REV00 12-LCM17-G001-REV00
1A300 SECTIONS
SEE FIXTURE PLAN & ELEVATION SHEETS FOR MORE INFORMATION
SEE FIXTURE PLAN & ELEVATION SHEETS FOR MORE INFORMATION
SEE FIXTURE PLAN & ELEVATION SHEETS FOR MORE INFORMATION
2
AD200 EXISTING CEILING PLAN DEMOLITION
EXISTING OCCUPANCY:
BUILDING:
MECHANICAL:
M (MERCANTILE) B (BUSINESS) - NO CHANGE
IIBCONSTRUCTION TYPE:
FIRE:
PLUMBING:
ELECTRICAL
ACCESSIBILITY CODE:
ENERGY:
SPRINKLERED: YES
FIRE ALARM: YES
FIRE EXTINGUISHERS: YES
RETAIL SALES AREA 706 SF. / 30 = 24
TOTAL OCCUPANT LOAD
29 OCCUPANTS
OCCUPANT LOAD: TABLE 1004.1.1
2015 INTERNATIONAL BUILDING CODE (IBC)
2015 INTERNATIONAL FIRE CODE (IFC)
2015 INTERNATIONAL PLUMBING CODE (IPC)
2014 NATIONAL ELECTRICAL CODE (NEC)
2012 TEXAS ACCESSIBILITY STANDARDS
2015 INTERNATIONAL ENERGY CONSERVATION CODE (IECC)
2015 INTERNATIONAL MECHANICAL CODE (IMC)
TOTAL AREA 1178 S.F. GROSS =
BUISINESS AREA 472 S.F. / 100 = 5
2.) ACTUAL WIDTH PROVIDED:
EGRESS WIDTH PER OCCUPANT: 0.2 INCHES PER PERSON
1.) EGRESS COMPONENTS SPRINKLERED)
0.2 INCHES PER OCCUPANT x 29 OCCUPANTS = 6" INCHES (REQUIRED)
SEE EGRESS PLAN THIS SHEET AND SHEET V100 FOR
EGRESS LOCATIONS
PROPOSED OCCUPANCY: M (MERCANTILE) B (BUSINESS) - NO CHANGE
"OPEN" TO EXISTING MACY'S - REFERENCE FLOOR PLAN
PROJECT
LOCATION
NORTH
EGRESS PLAN
2
NEXTORE STORE PLANNER
JULIE NOTO
(860) 431-9646
NOTE:
ANY QUESTIONS REGARDING THESE CONSTRUCTION DOCUMENTS SHOULD BE
DIRECTED TO THE NEXTORE PROJECT MANAGER FOR APPROPRIATE DIRECTION OF
COMMUNICATION.
SK3
SK7
XB-TOWEL-C
EXTERIOR
VESTIBULE
TRAVEL DISTANCE +/-80'-0"
TRAVEL
DISTANCE
+/-45'-0"
GENERAL
INFORMATION
COVER SHEET
G001
1
5/17/2017 OWNERS COMMENTS
Seal
ByDateMark
Revisions:
a
ap
p
4000 Luxottica Place, Mason, OH 45040
6 Creamery Brook, East Granby, CT 06026
+1 (513) 765-6000
+1 (516) 393-2484
SheetDate
Drawn By
Checked By
Title
ISSUED FOR:
Nextore project
Number
Client Review
DOB Permit
DOB Permit - Re-Submit
Bid
Construction
LL Approval
Brand Design Type:
Construction for:
Nextore Store Design Revision No.:
DESIGN & CONSTRUCTION
MANAGEMENT:
74149
DESIGN REV 01
MODULAR
11/9/2017
STAFF
STAFF
4000 Luxo
ttica Place M
aso
n, O
hio
45040
A Sub
sid
iary o
f the Luxo
ttica G
ro
up
Architect / Engineer Job No.:
LCM 012
Architect of Record
2
11/10/2017 OWNERS COMMENTS
EXISTING MACY'S
FLOOR PLAN
1ST FLOOR
V100
Existing Macy's First Floor Plan
SCALE: 1/16" = 1'-0"
1
PLAN NORTH
1
5/17/2017 OWNERS COMMENTS
Seal
ByDateMark
Revisions:
a
ap
p
4000 Luxottica Place, Mason, OH 45040
6 Creamery Brook, East Granby, CT 06026
+1 (513) 765-6000
+1 (516) 393-2484
SheetDate
Drawn By
Checked By
Title
ISSUED FOR:
Nextore project
Number
Client Review
DOB Permit
DOB Permit - Re-Submit
Bid
Construction
LL Approval
Brand Design Type:
Construction for:
Nextore Store Design Revision No.:
DESIGN & CONSTRUCTION
MANAGEMENT:
74149
DESIGN REV 01
MODULAR
11/9/2017
STAFF
STAFF
4000 Luxo
ttica Place M
aso
n, O
hio
45040
A Sub
sid
iary o
f the Luxo
ttica G
ro
up
Architect / Engineer Job No.:
LCM 012
Architect of Record
2
11/10/2017 OWNERS COMMENTS
TRUE NORTH
EXISTING WALLS TO REMAIN
LEASE LINE
CENTER LINE
CONSTRUCTION TO BE
DEMOLISHED
A. THE G.C. SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE THE SAFETY OF THE PUBLIC AND/OR
WORKMEN ON THE JOB AND TO PREVENT ACCIDENTS OR INJURY TO ANY PERSON ON, ABOUT, OR
ADJACENT TO THE PREMISES. THE G.C. SHALL COMPLY WITH ALL LAWS, ORDINANCES, CODES, RULES
AND REGULATIONS RELATIVE TO SAFETY AND THE PREVENTION OF ACCIDENTS.
B. THIS DEMOLITION PLAN IS TO BE USED IN CONJUNCTION WITH THE ENTIRE SET OF WORKING
DRAWINGS. DO NOT REMOVE OR DEMOLISH ANYTHING WITHOUT VERIFYING AND COORDINATING
WITH ALL GENERAL TRADES AS TO HOW THEY RELATE TO THE OVERALL PROJECT.
C. THE G.C. SHALL BE RESPONSIBLE FOR REMOVING OR DEMOLISHING EXISTING CONSTRUCTION WHICH
WILL INTERFERE WITH THEIR NEW WORK AND ANY TEMPORARY BRACING OR PERMANENT SUPPORT
STRUCTURES.
D. WHEN EXISTING ELECTRICAL SERVICE, POWER, AND LIGHTING IS REMOVED, STUB BACK AND CAP AS
REQUIRED IN AREAS BETWEEN EXISTING CONDITIONS AND NEW WORK.
E. REMOVE EXISTING FLOORING MATERIAL, CAP EXISTING MECHANICAL, PLUMBING AND ELECTRICAL
SERVICES FLUSH WITH EXISTING SLAB AS REQUIRED, TYPICAL THROUGHOUT; REFER TO RESPONSIBILITY
SCHEDULE ON SHEET G002 FOR FLOORING PREPARATION.
F. AT THE G.C.'S OPTION, DEMOLISH OR REMOVE MORE OR LESS EXISTING WORK, PROVIDED THAT SUCH
VARIATION WILL EXPEDITE THE PROJECT AND NOT INCREASE THE EXPENSE TO THE OWNER OR
VIOLATE ANY CODES. THESE OPTIONS SHALL BE SUBJECT TO THE NEXTORE'S PROJECT MANAGER'S
APPROVAL.
G. COORDINATE ANY SYSTEMS SHUTDOWNS WITH LANDLORD & INCLUDE COSTS OF SHUTDOWN IN THE
BID.
H. EXCEPT AS NOTED, G.C. SHALL INCLUDE COSTS TO CUT, PATCH AND/OR REPAIR EXISTING WORK AND
EXISTING FACILITIES WHICH MAY BE DISTURBED DURING INSTALLATION OF NEW WORK IN BID
PACKAGES.
WALL TYPE LEGEND
#KEY NOTES
GENERAL NOTES
I. IN ACCORDANCE WITH THE DRAWINGS, THOSE ITEMS WHICH ARE REMOVED, AND ARE NOT
RELOCATED OR REUSED, SHALL BE DISPOSED OF BY THE G.C.
J. ANY EXISTING DOORS AND FRAMES TO BE REMOVED UNLESS NOTED OTHERWISE ON PLANS; REFER TO
DOOR SCHEDULE.
K. ANY EXISTING RECEPTACLES TO REMAIN UNLESS NOTED OTHERWISE ON PLANS; REFER TO ELECTRICAL
DRAWINGS.
L. REMOVE ALL WALL VINYL FROM WALLS (AS REQUIRED) AND PREP WALLS FOR NEW FINISHES.
M. G.C. TO INSPECT ALL EXISTING WALLS TO REMAIN AND ENSURE THAT THEY ARE UP TO CURRENT
SPECIFICATIONS.
N. G.C. TO PROVIDE AND INSTALL TEMPORARY BARRICADE PER DETAIL. SUBJECT TO CHANGE PER MACY'S
REQUIREMENTS. GC TO ITEMIZE COST OF BARRICADE.
O. PRIOR TO INSTALLATION OF NEW FLOOR, GC TO VERIFY EXISTING FLOOR CONDITIONS MEETS AND ARE
IN COMPLIANCE WITH ANSI STANDARD FOR THIN SET TILE AND THE LATEST EDITION OF TILE COUNCIL
OF AMERICA. IF THERE ARE ISSUES OR DEFICIENCIES, CONTACT NEXTORE PROJECT MANAGER PRIOR TO
INSTALLATION.
4. EXISTING MACY'S TILE FLOORING TO REMAIN.
PROPOSED LENSCRAFTER'S AREA:
EXISTING MASONRY WALLS TO
REMAIN
EXISTING FLOOR PLAN / DEMOLITION
SCALE: 1/4" = 1'-0"
1
BARRICADE:
11. G.C. TO PROVIDE TEMP CONSTRUCTION BARRICADE. G.C. TO FIELD DETERMINE EXACT CONFIGURATION OF BARRICADE AS NECESSARY TO COMPLETE THE OVERALL
SCOPE OF WORK. COORDINATE LOCATION OF A 3' OPENING FOR ACCESS. WITH MACY'S AND NEXTORE REPRESENTITIVES. G.C. IS TO PROTECT THE EXISTING
FLOORING ON BOTH SIDES OF THE BARRICADE. SEE TYPICAL DETAIL THIS SHEET.
GENERAL: G.C. TO FIELD VERIFY IF ANY EXISTING STORE FIXTURES ARE WITH-IN THE LIMITS OF THE LENS CRAFTERS AREA. COORDINATE WITH MACY'S FACILITIES
REPRESENTATIVES AND HAVE REMOVED.
BARRICADE
7. EXISTING PARTITIONS AND DOORS ,HARDWARE TO BE REMOVED WHERE INDICATED. ANY EXISTING ELECTRICAL TO BE REMOVED BACK TO NEAREST J-BOX AND
MADE SAFE.
8. EXISTING MILLWORK DIVIDERS TO BE REMOVED.
DUST BARRIER:
12. G.C. TO PROVIDE DUST BARRIER (FLAME RETARDANT POLY TARP HEAVY DUTY ) MEETING THE FIRE RESISTANCE REQUIREMENTS OF NFPA 241, SEE DETAIL THIS SHEET.
10'-8"
HA
RD
BA
RR
IC
AD
E
MIN
.
EXIST. CEIL.
CLEAR PLASTIC
OR FIRE RATED
TARP AS REQUIRED
CO
NSTR
UC
TIO
N SID
E
AT TILE:
3
5
8
" X 25 GA METAL TRACK
SECURE TO FLOOR WITH CONCRETE SCREWS
@ 48" O.C. IN GROUT JOINTS. PATCH AND
REPAIR GROUT JOINTS UPON REMOVAL.
24"
AT CARPET:
3
5
8
" X 25 GA METAL TRACK
SECURED TO 3/4" PLYWOOD W/ SCREWS @ 48" O.C.;
PROVIDE WEIGHT (MULTIPLE SAND BAGS SPACED) AS
REQUIRED FOR TEMP WALL STABILITY.
WEIGHT
3 5/8" x 20 GA. METAL
STUDS AT 24" O.C. w/
1/2" GWB (1) SIDE TO
4'-0" A.F.F.; GC TO PAINT
STORE SIDE WHITE,
LEVEL 3 FINISH.
3
5
8
" X 25 GA METAL STUD
DIAGONAL BRACING
@ 48" O.C.
3
4
" FRT PLYWOOD
2'-0"
5. EXISTING CARPETING TO BE REMOVED FROM ADJACENT MACY'S AREA. COORDINATE ON SITE WITH MACY'S REPRESENTATIVE FOR EXACT DIMENSIONs AND
TIMING SCHEDULE OF DEMOLITION.
1. EXISTING MACY'S AREA TO REMAIN INCLUDING ALL FIXTURES, FINISHES, FLOORING, ETC.
2. EXISTING PARTITION TO REMAIN ALONG WITH DOOR, FRAME, AND HARDWARE.
3. EXISTING CARPET AND WALL BASE IN PROPOSED LENS CRAFTER'S AREA LIMITS TO BE REMOVED BACK TO CONCRETE SLAB. CLEAN, SCRAPE, AND REMOVE ALL
ADHESIVES AS REQUIRED FOR NEW FLOOR INSTALLATION. COORDINATE WITH MFG REQUIREMENTS FOR NEW FLOORING PREP REQUIREMENTS.
6. EXISTING MACY'S WOOD PLANK FLOORING TO REMAIN.
9. REMOVE EXISTING SLATWALL, FIXTURES AND HARDWARE AS INDICATED. PATCH, REPAIR, AND PROVIDE NEW VENEER LAYER OF 5/8 GYP. BD. TO ENSURE A SMOOTH
AND FLAT SURFACE (LEVEL 4 FINISH).
10. REMOVE SECTION OF EXISTING DISPLAY AREA ALUMINUM FRAMING AND GLASS AS INDICATED. NOTE: COORDINATE WITH MACY'S REPRESENTATIVE AND APPLY
TEMPORARY CONSTRUCTION FILM TO REMAINING DISPLAY GLASS AS REQUIRED.
5
3 4
1TRENCH REPAIR DETAIL
1-LCM17-AD100-REV00
2-LCM17-AD100-REV00
2BARRICADE DETAIL
TEMPORARY BARRICADE
TEMPORARY BARRICADE SHALL BE CONSTRUCTED PER
LL REQUIREMENTS
TEMPORARY BARRICADE IS TO BE 100% COMPLETE
AND READY FOR GRAPHICS TO BE INSTALLED NO MORE
THAN (2) DAYS AFTER CONSTRUCTION START. G.C. TO
CONTACT OWNER'S REPRESENTATIVE UPON COMPLETION
TO COORDINATE GRAPHICS INSTALLATION. TEMPORARY
BARRICADE MUST BE PRIMED AND PAINTED WITH (2) COATS
OF EITHER EGGSHELL OR SEMI-GLOSS FINISH ONLY.
GC IS RESPONSIBLE FOR MAINTAINING BARRICADE
DURING CONSTRUCTION.
REMOVE BARRICADE WHEN 100% OF STOREFRONT OR
JOB IS COMPLETED ON THE EVENING BEFORE G.C.'S
PUNCHLIST IS COMPLETED, PRIOR TO OWNER VERIFICATION,
AND AFTER LL APPROVAL IS RECEIVED. CARE IS TO BE TAKEN
WHEN DISSEMBLING AND REMOVING BARRICADE, ON
INTERIOR SIDE (STORE SIDE), PAPER WINDOWS WITH WHITE
CONSTRUCTION PAPER OVER GLAZING ONLY. TRIM 1/2" OFF
EDGES AND TAPE CONTINUOUSLY AROUND PERIMETER WITH
WHITE TAPE. G.C. IS TO RESTORE NEUTRAL PIER(S), MALL
FLOORING & BULKHEAD TO A LIKE NEW CONDITION AND
FINISH WHERE APPLICABLE.
3-LCM17-AD100-REV00
4-LCM17-AD100-REV00
5-LCM17-AD100-REV00
31'-11 1/2"
TRUE NORTH PLAN NORTH
MACY'S RETAIL AREA
EN
TRY
VE
STI
BU
LE
LEASE LINE
GC RESPONSIBLE TO SPEAK, ON-SITE, WITH
MACY’S OPERATIONS MANAGER TO VERIFY
EXTENTS OF DEMOLITION, PRIOR TO THE
REMOVAL OF ANY WALLS, FLOORING, ETC.
PROPOSED LENSCRAFTERS
-1178 GROSS SQ. FT.
-LEVEL 2 OF 3
-FULLY SPRINKLERED
-EXISTING FIRE ALARM
AD100
2
NOTE:
PRIOR TO INSTALLATION OF CONSTRUCTION BARRICADE
G.C. TO VERIFY EGRESS REQUIREMENTS WITH MACY'S REP.
AND FIRE AND OR BLDG. DEPT.. ADJUST PROPOSED
BARRICADE LOCATION / INSTALL DOOR(S) AS REQUIRED
1
3
1112
NOTE: REFERENCE MEP PLANS FOR
INFORMATION DESCRIBING ANY REQUIRED
CORE DRILLING AND OR FLOOR TRENCHING
TYP.
2
4
11
12
EXISTING TILE BORDER (TO REMAIN).
-SEE FINISH PLAN (TYPICAL)
EXTERIOR1
1
EXISTING COLUMN ENCLOSURE
WITH FULL HEIGHT MIRROR (4)
SIDES TO REMAIN. NEW BASE TO
BE INSTALLED.
3
9
8
NOTE: EXISTING WALL
STANDARDS TO BE REMOVED.
G.C. TO RETURN WALL
STANDARDS TO MACY'S
(TYPICAL)
EXISTING CARPET OUTSIDE OF LEASE
AREA TO REMAIN (N.I.C.). -SEE PLANS
MACY'S RETAIL AREA
MACY'S RETAIL AREA
N.I.C.
N.I.C.
N.I.C.
1
N.I.C.
LEASE LINE
EXISTING CONSTRUCTION TO BE
REMOVED THIS AREA AS REQUIRED FOR
INSTALL NEW MAN DOOR. SEE PLANS
FOR ADDITIONAL INFORMATION.
EXTERIOR
4
7
EXISTING FLOOR MOUNT ELECT.
DEVICES TO BE REMOVED. REFERENCE
GENERAL NOTES THIS SHEET FOR
REQUIREMENTS. REPAIR FLOOR AS
REQUIRED. (TYP.)
8
9
7
7
7
EXISTING FLOOR FIXTURES TO BE
REMOVED. G.C. TO RETURN TO
MACY'S (TYPICAL THROUGHOUT
SPACE)
NOTE:
MAINTAIN ACCESS TO ANY EXISTING VALVES,
CLEAN-OUTS, ETC. NOTIFY NEXTORE CONSTRUCTION
MANAGER OF ANY CONFLICTS.
SIM.
EXISTING CASHWRAP
TO BE REMOVED.
RETURN TO MACY'S.
NOTE:
EXISTING EQUIPMENT THIS AREA TO BE
RELOCATED ABOVE NEW FINISH CEILING
THIS AREA. G.C. TO FIELD VERIFY EXISTING
CONDITIONS AND DISCUSS REQUIRED
SCOPE OF WORK WITH ON-SITE MACY'S
REP. PRIOR TO BID SUBMITTAL.
2-LCM17-AD100-REV01
6BARRICADE DETAIL
GC IS RESPONSIBLE FOR MAINTAINING
BARRICADE DURING CONSTRUCTION.
REMOVE BARRICADE WHEN 100% OF
STOREFRONT OR JOB IS COMPLETED ON
THE EVENING BEFORE G.C.'S PUNCHLIST
IS COMPLETED, PRIOR TO OWNER
VERIFICATION, AND AFTER LL APPROVAL
IS RECEIVED. CARE IS TO BE TAKEN WHEN
DISSEMBLING AND REMOVING
BARRICADE, ON INTERIOR SIDE (STORE
SIDE), PAPER WINDOWS WITH WHITE
CONSTRUCTION PAPER OVER GLAZING
ONLY. TRIM 1/2" OFF EDGES AND TAPE
CONTINUOUSLY AROUND PERIMETER
WITH WHITE TAPE. G.C. IS TO RESTORE
NEUTRAL PIER(S), MALL FLOORING &
BULKHEAD TO A LIKE NEW CONDITION
AND FINISH WHERE APPLICABLE.
B.O.
CEILING
VERIFY IN
FIELD
ZIPWALL DUST BARRIER
SYSTEM
PROVIDED AND
INSTALLED BY G.C..
6 MIL. FIRE RATED
OPAQUE PLASTIC. VERIFY
CEILING FOR POLE SIZE
REQUIRED. VERIFY WITH
MACYS FOR LOCATION OF
ACCESS.
ZIPWALL FOAMRAIL
SPAN
@ CEILING &
WALLS
ZIPWALL GRIPDISKS
1
NOTE:
G.C. TO VERIFY BARRICADE REQUIREMENTS THIS AREA
WITH NEXTORE CONSTRUCTION MANAGER AND ON-SITE
MACY'S REPRESENTATIVE.
1
2
2"
C
L
EX. VAPOR BARRIER V.I.F.
10"
ALIGN
NEW VAPOR BARRIER
4"
OVERLAP
OVERLAP
1'-6"
DOWEL IN REBAR SET IN EPOXY
TAPE SEAM
NEW CONCRETE
EX. SLAB
4"
OVERLAP
4"
CONDUITS PER
ELECTRICAL DWGS
4" 4"
#4 BARS @ 12" O.C.
EXISTING COMPACTED
SUB-GRADE
EXISTING
FLOOR PLAN /
DEMO
AD100
1
5/17/2017 OWNERS COMMENTS
Seal
ByDateMark
Revisions:
a
ap
p
4000 Luxottica Place, Mason, OH 45040
6 Creamery Brook, East Granby, CT 06026
+1 (513) 765-6000
+1 (516) 393-2484
SheetDate
Drawn By
Checked By
Title
ISSUED FOR:
Nextore project
Number
Client Review
DOB Permit
DOB Permit - Re-Submit
Bid
Construction
LL Approval
Brand Design Type:
Construction for:
Nextore Store Design Revision No.:
DESIGN & CONSTRUCTION
MANAGEMENT:
74149
DESIGN REV 01
MODULAR
11/9/2017
STAFF
STAFF
4000 Luxo
ttica Place M
aso
n, O
hio
45040
A Sub
sid
iary o
f the Luxo
ttica G
ro
up
Architect / Engineer Job No.:
LCM 012
Architect of Record
2
11/10/2017 OWNERS COMMENTS
N
O
T
U
S
E
D
#
KEY NOTES
EXISTING MACY'S AREA:
EXISTING CEILING PLAN / DEMO
SCALE: 1/4" = 1'-0"
1
PROPOSED LENSCRAFTER'S AREA:
2. EXISTING DRYWALL CEILINGS TO REMAIN ALONG WITH ALL LIGHTING FIXTURES AND HVAC DIFFUSERS
UNLESS NOTED OTHERWISE. CLEAN AND RELAMP EXISTING FIXTURES AS REQUIRED.
EXISTING CEILING LEGEND
1. EXISTING MACY'S CEILINGS TO REMAIN INCLUDING , GYP. BD. CEILINGS, ALL LIGHTING, AUDIO SPEAKERS, AND
HVAC DIFFUSERS TO REMAIN UNLESS OTHERWISE NOTED.
5. REMOVE SECTIONS OF EXISTING BACK LIT MILLWORK TYPE VALANCE ALONG WITH ALL LIGHT FIXTURES
AS INDICATED. ALL ELECTRICAL IS TO BE REMOVED BACK TO NEAREST J-BOX AND MADE SAFE. RETURN
LIGHTING FIXTURES TO MACY'S REPRESENTATIVE.
3. REMOVE EXISTING RECESSED DOWNLIGHT AS INDICATED. RETURN FIXTURE TO MACY'S
REPRESENTATIVE. ALL ELECTRICAL TO BE REMOVED BACK TO NEAREST J-BOX AND MADE SAFE.
4. REMOVE EXISTING SPEAKER AS INDICATED. SAVE FIXTURE FOR RELOCATION AS REQUIRED.
COORDINATE WITH REFLECTED CEILING PLAN SHEET A102 FOR DETAILS.
6. EXISTING AREA OF SUSPENDED CEILING TO BE REMOVED AS INDICATED INCLUDING ALL LIGHT
FIXTURES, SPRINKLER HEADS, DIFFUSERS, ETC.. ALL FIXTURES TO BE RETURNED TO MACY'S
REPRESENTATIVE. ALL ELECTRICAL TO BE REMOVED BACK TO NEAREST J-BOX AND MADE SAFE.
7. REMOVE LIGHT FIXTURES. FIXTURE TO BE RELOCATED. SEE CEILING PLAN SHEET A102 FOR NEW
LOCATIONS.
8. REMOVE AREAS OF EXISTING GYP. BD. SOFFIT DROPS AND ANY ASSOCIATED LIGHTING. REMOVE
ELECTRICAL BACK TO POINT OF SERVICE.
2
1-LCM17-AD200-REV00
1
2-LCM17-AD200-REV00
TRUE NORTH PLAN NORTHEXISTING RECESSED DOWN LIGHTING
EXISTING EXIT SIGN
EXISTING SPRINKLER HEAD
EX4
SPKR
EX2
EXISTING RECESSED DOWN LIGHTING
EXISTING SPEAKER
CAMEXISTING CAMERA
EX1
EXISTING 2 X 2 FLUORESCENT
EXISTING STRIP FLUORESCENT
EX3
RELOCATED SPRINKLER HEAD
EX5
EX6
EXISTING STRIP FLUORESCENT
1
EXISTING DUCT
BTM. AT 13'-1"
INDICATES EXISTING SPRINKLER
HEAD TO BE RELOCATED.
REFERENCE PLANS FOR
ADDITIONAL INFORMATION
INDICATES APPROXIMATE
LOCATION BARRICADE AT CEILING.
ADJUST INSTALL LOCATION AS
REQUIRED TO PROVIDE SAFE
CONDTION
LEASE LINE
1
(N.I.C.)
5
1
(N.I.C.)
1
(N.I.C.)
9'-2 3/4"
8'-2 7/8"
SOFFIT HT. = 10'-1"
EXISTING
6
6
6
SOFFIT HT. = 10'-1"
EXISTING
DECK HT. = 17'-0 1/2"
EXISTING OPEN TO DECK
SOFFIT HT. = 10'-6 1/2"
EXISTING
SOFFIT HT. = 10'-6 1/2"
EXISTING
1
EXISTING DUCT BTM. @ 9'-2 1/2"
EXISTING 16" DUCT
EXISTING DUCT
BTM. @ 11'-10 1/4"
EXISTING SPRINKLER
LINE BTM. @ 8'-6 3/4"
EXISTING LIGHT FIXTURE TO BE
REMOVED. NOTE: G.C. TO
RETURN FIXTURES TO MACY'S
LEASE LINE
LEASE LINE
8
3
5
5
5
2
EXISTING DUCT BTM.
AT 9'-2
1
2
" AT WALL
(SLOPES "UP" FROM
THIS LOCATION)
NOTE: FIELD VERIFY EXISTING SPRINKLER
VALVE REQUIREMENTS THIS AREA. NOTIFY
NEXTORE CONSTRUCTION MANAGER OF
ANY REQUIRED MODIFICATIONS PRIOR TO
BID SUBMITTAL
NOTE: G.C. TO SUPPLY AND INSTALL SUPPORT
FRAMING AS/IF REQUIRED FOR EXISTING
DUCTWORK THIS AREA (EXISTING PARTITION
REMOVAL THIS AREA MAY REQUIRE NEW
SUPPORT FRAMING FOR EXISTING DUCTWORK)
EXISTING CEILING
PLAN / DEMO
AD200
1
5/17/2017 OWNERS COMMENTS
Seal
ByDateMark
Revisions:
a
ap
p
4000 Luxottica Place, Mason, OH 45040
6 Creamery Brook, East Granby, CT 06026
+1 (513) 765-6000
+1 (516) 393-2484
SheetDate
Drawn By
Checked By
Title
ISSUED FOR:
Nextore project
Number
Client Review
DOB Permit
DOB Permit - Re-Submit
Bid
Construction
LL Approval
Brand Design Type:
Construction for:
Nextore Store Design Revision No.:
DESIGN & CONSTRUCTION
MANAGEMENT:
74149
DESIGN REV 01
MODULAR
11/9/2017
STAFF
STAFF
4000 Luxo
ttica Place M
aso
n, O
hio
45040
A Sub
sid
iary o
f the Luxo
ttica G
ro
up
Architect / Engineer Job No.:
LCM 012
Architect of Record
2
11/10/2017 OWNERS COMMENTS
GENERAL NOTES
A. G.C. TO REFERENCE FIXTURE CONTRACTORS SHOP DRAWINGS FOR
INSTALLATION INSTRUCTIONS FOR ALL FIXTURES, WALL CABINETS,
BASE CABINETS, AND COUNTERTOPS. G.C. TO COORDINATE WITH
FIXTURE CONTRACTOR TO ENSURE PROPER FIT OF ALL COMPONENTS.
B. G.C. TO ENSURE FIXTURES ARE PROTECTED DURING CONSTRUCTION.
C. G.C. TO PROVIDE ADEQUATE BRACING, AS REQUIRED, IN WALLS TO
SUPPORT WALL CABINETS AND FIXTURES.
D. G.C. TO FURNISH AND INSTALL LOCKSET OPERATIONAL BY TENANT
ONLY.
E. G.C. TO SIGN FOR PACKAGES WITH A NOTE "SUBJECT TO CONCEALED
DAMAGES" ON IT.
F. G.C. TO REFER TO GRAPHICS STANDARD MANUAL FOR GRAPHIC
MOUNTING HEIGHTS, TYPICAL.
G. E = EXISTING TO REMAIN.
M = EXISTING TO BE RELOCATED.
F= FUTURE EQUIPMENT
H. REFER TO ELEVATION SHEETS A200-A201 FOR ACCESSIBILITY ACCESS
SIGNAGE
1. GRAPHIC PACKAGE ITEMS; REFER TO RESPONSIBILITY SCHEDULE ON G001 AND GRAPHICS SCHEDULES THIS SHEET
FOR RESPONSIBILITIES. REFER TO INTERIOR ELEVATIONS FOR MOUNTING DIMENSIONS AS APPLICABLE.
2. CENTER MILLWORK / GRAPHICS ON THIS LINE.
3. DOCTOR'S EQUIPMENT. REFER TO RESPONSIBILITY SCHEDULE ON G001.
4. COAT HOOK AT 48" TO CENTERLINE OF HOOKS.
5. 2A-10BC FIRE EXTINGUISHERS AS DIRECTED BY THE FIRE MARSHAL. (SUGGESTED LOCATIONS ON PLAN.)
6. GC TO USE PERIMETER FIXTURE DIMENSIONAL DATA (THIS PAGE) FOR PROPER WALL LENGTH.
7. COORDINATE DIMENSIONS FOR MILLWORK WITH TENANTS MILLWORKER.
8. G.C. TO APPLY PAINTABLE CAULK WHERE MILLWORK COUNTERS MEETS GYP BD. WALL.
9. INSTALL PERIMETER WALL FIXTURES SEQUENTIALLY STARTING AT THIS POINT. GC TO VERIFY ADJACENT WALL IS
CLEAN, LEVEL,
STRAIGHT AND PLUMB.
10. CL-SHELF-36/48 - (2) 3/4" THICK x 12" DEEP WHITE MELAMINE SHELVES, FINISHED ON ALL SIDES, FASTENED TO 6'-0"
TALL WHITE DOUBLE SLOTTED STANDARDS AND BRACKETS AT 18"O.C. BOTTOM OF STANDARDS TO START 18" A.F.F.
AND FIRST SHELF TO BE MOUNTED AT 48" A.F.F.
11. DOCTOR'S CERTIFICATES/ LICENSES TO BE INSTALLED AT THIS LOCATION.
12. NOT USED
13. REFER TO ELECTRIC SHEETS FOR ELECTRICAL / DATA FLOOR BOX LOCATIONS. (TYP.)
14. SEE ELEVATION SHEET(S) FOR LOCATION OF START AND END POINTS OF WALL FINISH. SEE SHEET A103 FOR
FINISH SCHEDULE.
15. SANITARY PUMP. REFER TO PLUMBING AND ELECTRIC SHEETS FOR APPLICABLE INFORMATION.
16. HIPPA / OPTICIANS LICENSE TO BE INSTALLED AT THIS LOCATION.
FIXTURE PLAN - KEY NOTES
#
CAPACITY CALCULATIONS
FIXTURE TYPEQUANTITY
CAPACITY TOTAL
48" WALL FIXTURE 1 72 72
24" WALL FIXTURE 2 36 72
ENDCAP 5 15 75
4' GONDOLA TABLE 4 92 368
TOTAL
FIXTURE - FLOOR PLAN
SCALE: 1/4" = 1'-0"
1
3
1
8
"
10
3 8
"
1
5
8
"
10
3 8
"
4'-0"
1'-6
1 4
"
2'-0"
1'-6
1 4
"
1'-6"
10
3 8
"
7'-4"
SALES AREA - BACKWRAP FIXTURE DIMENSIONAL DATA
& PERIMETER WALL FIXTURE DIMENSIONAL DATA
(NOT ALL FIXTURES MAY BE USED IN PROJECT.
FOR REFERENCE AND LAYOUT PURPOSES ONLY)
1 3
4
5
3
ENGAGEMENT
TABLES
1 20 20
607
5-LCM17-A100-REV00 6-LCM17-A100-REV00
EQUIPMENT #DESCRIPTION
FIXTURE FLOOR PLAN - SCHEDULE
FURNITURE # DESCRIPTION
MILLWORK
GLOBAL #
DESCRIPTION
GRAPHICS # DESCRIPTION
LCM-MW-CS
SK7
SK3
EQ100C
EQ101
EQ102
EQ108
EQ109B
EQ112
EQ118C
EQ119
EQ6A
EQ8C
EQ21
EQ22A
BLOCKING
BLOCKING
BLOCKING
BLOCKING
LENSOMETER (AUTO)
FRAME TRACER
EYE NET STATION
FRAME WARMER (HOT AIR)
TRIPLE POWER TABLE
TONOMETER
AUTO-REFRACTOMETER
PATIENT CHAIR
REFRACTION STAND
STOOL
CHAIR MOVER
LCD SCREEN
SINK
SINK
MAIN WALL CABINET SIGN
EQ105CFIELDS TESTER
GS-FN07 STOOLS FOR SELECT TABLE
GS-FN04 LOUNGE CHAIR
GS-FN08(A)(B)(C) ADJ. TASK CHAIR("A"-HARD SURF. "B"-CARPET "C"-CALIFORNIA)
GS-FN09 SIDE CHAIR
GS-FN09CSIDE CHAIR (CALIFORNIA STORES)
GS-FN02(A)(B)(C) ADJ. STOOL ("A"-HARD SURF. "B"-CARPET "C"-CALIFORNIA)
GS-FN05SIDE TABLE (W/ GS-FN04 CHAIRS)
GS-LF20
GS-LF21
GS-LF42
GS-LF50
GS-PW31
GS-PW60
GS-PW61
GS-PW62
GS-CL02(L)
SE-CL03
SE-OD01(L)
SE-OD02
SE-OD03
GS-CW20 CASHWRAP, LC SIS
27" (H) JOJOGS-LF10
35" (H) JOJOGS-LF11
GS-LF13 FRONT DOOR FOCAL
27" (H) ENGAGEMENT TABLE
33" (H) ENGAGEMENT TABLE
SELECT BAR
CAPACITY FIXTURE ENDCAP
CAPACITY FIXTURE, 2-BAYGS-LF51
CAPACITY FIXTURE, 3-BAYGS-LF52
FITTING/SELECT TABLEGS-LF70
FITTING/CASHWRAPGS-LF71
COLUMN PANEL, WITH BRAND MENUGS-LF90
GS-LF91SERVICE TOTEM, FLOOR FIXTURE
EASEL FIXTUREGS-LF92
GS-LF93COLUMN PANEL, WITH MIRROR
GS-PW01 (L)3" PERIMETER FIN ("L"=LEFT )
GS-PW10 48" (W) PERIMETER WALL UNIT
GS-PW11 25" (W) PERIMETER WALL UNIT
GS-PW30 18" (W) MIRROR CABINET WITH STORAGE
12" (W) MIRROR CABINET WITH STORAGE
BACKWRAP FEATURE
BACKWRAP FEATURE WITH SIGNAGE
BACKWRAP FEATURE WITH WOOD FRAME
GS-PW80 FILLER WITH MIRROR, NO STORAGE
GS-PW81 PORTAL VERTICAL MODULE
GS-PW82 PORTAL HORIZONTAL MODULE
GS-PW83 WOOD FIN VERTICAL
GS-PW84 CORNER FILLER
GS-PW91 SERVICE TOTEM, WALL MOUNTED
GS-PW93 MIRROR, OVERALL SIZE MATCHES LF90/93
GS-PW94 FRAME LEDGE, 26" W
GS-PW95 FRAME LEDGE, 48" W
BOH-UP24 UPPER CABINET
GS-BOH01(L) WORK COUNTER FOR SIS (LEFT)
SINK BASE FOR SIS (LEFT)
CONTACT LENS STORAGE
DOCTORS DESK (LEFT)
SINK BASE
SINK CABINET ABOVE
LCM-FW-CS FOCAL WALL CABINET SIGN
LCM-EE-CS EYE EXAMS CABINET SIGN
LCM-GR-32 ROOM ID SIGNS
LCI-GH-30 OD SNAP FRAMES
SE-GH-23CERTIFICATE / LICENSE SNAP FRAMES
LCM-GH-16 DOCTOR'S NAME SLAT SIGN
EQ100ASINGLE POWER TABLE
EQ6 LENSOMETER (MANUAL)
CHART HOLDERCHART HOLDER (WALL MOUNTED)
BLOCKING PROVIDED AND
INSTALLED BY G.C.
BLOCKING PROVIDED AND
INSTALLED BY G.C.
GONDOLA MONITORGS-LF53
GS-PW60_55 BACKWRAP W/ 55" DIGITAL MONITOR
GS-PW60_75 BACKWRAP W/ 75" DIGITAL MONITOR
GS-PW61_55 BACKWRAP FEATURE W/ SIGNAGE & 55" DIGITAL MONITOR
GS-PW61_75 BACKWRAP FEATURE W/ SIGNAGE & 75" DIGITAL MONITOR
GS-PW62_55 BACKWRAP FEATURE W/ SIGNAGE, PORTAL FRAME, & 55" DIGITAL MONITOR
GS-PW62_75 BACKWRAP FEATURE W/ SIGNAGE, PORTAL FRAME, & 75" DIGITAL MONITOR
FITTING/SELECT TABLE (REQUIRES WIRING BY GC)GS-LF70W
FITTING/CASHWRAP (REQUIRES WIRING BY GC)GS-LF71W
GS-CW20W CASHWRAP, LC SIS (REQUIRES WIRING BY GC)
GS-PW01A (L)3 1/8" PERIMETER FIN ("L"=LEFT)
LCM-FW-CS.1 FOCAL WALL CABINET SIGN FOR 75” DIGITAL MONITOR BACK WRAP
LCM-MW-CS.1 MAIN WALL CABINET SIGN
EQ120
EQ121
EQ122
EQ122C
REFRACTION ROOM CHAIR
REFRACTION ROOM CHAIR (CALIFORNIA)
LCM-DO-CS
6
OPTOS
OPTOS TABLE
0801-00
0303-00
0321-00
0300-00
0320-00
0307-00
0308-00
0322-00
0440-00
0440-00
0450-00
0831-00
0832-00
0833-00
0400-00
0420-00
0451-00
0186-00
0186-00
0831-00
0834-00
0832-00
0835-00
0833-00
0836-00
GS-PW01 (C)3" PERIMETER FIN ("C"=CENTER)
GS-PW01 (R) 3" PERIMETER FIN ("R"=RIGHT)
GS-PW01A (C)
GS-PW01A (R)
3 1/8" PERIMETER FIN ("C"=CENTER)
3 1/8" PERIMETER FIN ("R"=RIGHT)
0430-00
0440-00
0430-00
0440-00
BLOCKING PROVIDED AND
INSTALLED BY G.C.
MILLWORK
MODULAR #
GS-LF22ENGAGEMENT TABLE 20302-00
GS-LF70A FITTING-SELECT TABLE0306-00
GS-LF80 WELCOME TABLE0309-00
GS-LF75B (2) MODULAR SELECT TABLE0310-00
GS-LF75C (3) MODULAR SELECT TABLE0311-00
GS-PW76A BACKWRAP (4) 55" MONITORS0830-00
GS-PW40 CASHDESK OD (3) MODULES1800-00
GS-PW43 CASHDESK OD (2) MODULES1801-00
GS-PW41 BACKWRAP OD (4) 55" MONITORS1830-00
0920-00
0460-00
1811-00
1844-00
1846-00
1842-00
GS-BOH01(R) WORK COUNTER FOR SIS (RIGHT)1843-00
1860-00
GS-CL02(R) SINK BASE FOR SIS (RIGHT)1861-00
1863-00
SE-OD01(R) DOCTORS DESK (RIGHT)
1853-00
1854-00
1855-00
1856-00
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1'-0"
9
5 8
"
3
7
8
"
6"
NOTE: ALL SPECS MAY NOT BE USED IN EVERY STORE
GENERAL NOTE: FOLLOW ALL MANUFACTURERS
INSTALLATION AND MAINTENANCE INSTRUCTIONS
MISC
.
FIRE EXTINGUISHER - MULTI-PURPOSE DRY
CHEMICAL TYPE: UL RATED 1-A 10-B/C, 5 LB
KIDDE / GRAINGER
PARTS OF AMERICA
(800) 323-0620
PRO LINE #PR02-STCM
BRACKET 4T307
LARSEN'S 800-633-6668
(MP SERIES-MP5, W/B-2
WALL BRACKET
FOR CLASS A, B AND C FIRES
OTH
ER
PAPER TOWEL HOLDER - WALL MOUNTED STAPLES(800) 333-3330
SIMPLEHUMAN QUICK LOAD PAPER TOWEL HOLDER
WALL MOUNT - STAINLESS STEEL - ITEM#180969 MDL:
KT1024
NONE REFRACTION ROOM
PAPER TOWEL HOLDER - FREESTANDING STAPLES
SIMPLEHUMAN TENSION ARM PAPER TOWEL HOLDER
STAINLESS STEEL. ITEM#:180971 MDL#: KT1161
NONECONTACT LENS ROOM, OPTICAL STATION
COAT HOOK GRAINGER 1-800-GRAINGER
10G182 POLISHED CHROME DOUBLE ROBE HOOK, MODEL
#01-9402,
NONEOD ROOMS; INCLUDES MOUNTING HARDWARE
WALL STANDARDS
KNAPE & VOGT (OR
EQUAL)
HEAVY DUTY STEEL STANDARD
#KV85ANO (DOUBLE SLOT), WHITE
NONEREFER TO ELEV. FOR SIZE; PROVIDE BLOCKING AS REQUIRED
BRACKETS
KNAPE & VOGT (OR
EQUAL)
HEAVY DUTY W/ LOCK NUT
#KV187ANO, WHITE
NONE
SHELVING
3/4" TH. X 12"D WHITE MELAMINE FINISHED ON
ALL SURFACES
NONE
SHELVING RATED AT 100 LBS.
FASTEN SHELVES TO BRACKETS (DOUBLE SLOTTED STANDARDS)
CEILING ACCESS PANEL WIND-LOCK(800) 872-5625
TR-AP024 24" X 24" ACCESS PANEL NONE RETAIL SALES AREA
(800) 333-3330
ITEM / DESCRIPTION MFG./PHONE # MODEL #/COLORREMARKS
CABINET HANDLE DOOR BUMPER EVERBILT1 1/8" NAIL-ON MDL.: 49955 - HOME DEPOT
EQUAL TO COLOR
BACK OF HOUSE ONLY
ALTERNATE
SUPP. INST.
GC GC
T GC
T T
GC GC
GC GC
GC GC
GC GC
GC GC
GC GC
ARCHITECTURAL SPECIFICATIONS / FINISHES2
4-LCM17-A100-REV002-LCM17-A100-REV00
3-LCM17-A100-REV001-LCM17-A100-REV00
0440-00 0430-00
0400-00
0420-00
0450-00
0186-00
0834-00
0835-00
0836-00
0833-00
5'-8" 7'-4" 7'-4"
REC
ESSED
ELEC
TR
IC
PA
NEL
SK3
SK7
CLG. HT.=
PRETEST
102
10'-0"
CLG. HT.=
CONTACT LENS /
OPTICAL STATION
104
10'-0"
CLG. HT.=
REFRACTION
ROOM
101
10'-0"
CLG. HT.=
RETAIL SALES AREA
100
10'-6 1/2"
24'-8"
31'-11 1/2"
CLG. HT.=
OD RECEPTION
/ WAITING
103
8'-0"
0323-00
0321-00
E
Q
1
0
5
C
EQ100C
EQ101
E
Q
1
0
2
EQ121_F
EQ120_F
1801-00
GS-FN08AGS-FN02A
GS-FN08A
GS-FN08A
GS-FN02A
GS-FN
04
GS-FN
04
0
9
2
0
-
0
0
0
3
0
0
-
0
0
0302-00
0300-00
0308-00
GS-FN07
GS-FN
07
GS-FN
07
GS-FN07
0440-00
0451-00
0430-00
0440-00
0420-00
EQ118C
EQ6A
EQ
109B
EQ
108
EQ
119
EQ112
1853-00
SE-GH-CHART
LCI-GR32-EX1
XB-H
OO
K
0440-00
0440-00
0420-00
0400-00
0323-00
0321-00
0321-00
0323-00
0323-00
0321-00
1845-00
1811-00
LC
I-G
H16
SE-G
H24
0430-00
LC
I-G
H30
LC
I-G
H30
LCI-GH30
1846-00
0321-00
GS-FN08A
0201-00
1840-00 1840-00
1840-001840-00 1840-00
EQ21
EQ8C
EQ6EQ22A
XB-TOWEL-CLC
M-G
R-1
SE-G
R15 o
r 15.1
GS-FN
04
GS-FN
04
GS-FN
05
0835-00
0821-00
LC
M-M
W-C
S.2
0820-00
XB-D
FQ
55
EQ
22A
TRUE NORTH PLAN NORTH
7 14
FUTURE
EQUIPMENT
A2001
A200
3
4
5
6
MACY'S RETAIL AREA
MACY'S RETAIL AREA
6
1
1
1
11
8
74
13
MACY'S RETAIL AREA
SEE CONSTRUCTION
PLAN TO LOCATE
2
9
3'-8"
1'-6"
4'-0"
3'-8"
3'-3 1/2"
3
'-
5
"
4'-9"
4'-0"
A200
2
3
1
16
1
1
8
7
3 1
EXTERIOR
VESTIBU
LE
A200
7
8
9
10
A200
11
12
13
14
A200
15
(SIM.)
(SIM.)
5'-0 1/2"
FE
5
A500
14
7 MACY'S VESTIBULE DOOR HARDWARE
7-LCM17-A101-REV00
INSTALLSUPPLYSPECIFICATIONSITEM
SECURITY FILM
LOCKSET
CORE
DOOR CONTACT (BA)
MOTION DETECTOR (BA)
SECURITY DETAIL
MA
CY'S V
ESTIBU
LE D
OO
R
NOT REQUIRED
BURGLAR ALARM
NOT REQUIRED
NOT REQUIRED
9K SERIES BEST CYLINDER
COLOR: TO MATCH EXISTING MACY'S STOREFRONT
KEYED: SINGLE KEYED ENTRANCE
BEST STANDARD CORE
SFIC CONSTRUCTION CORE TO BE INCLUDED
KEYING: 7-PIN SFIC
FINISH: TO MATCH COLOR
NO. OF KEYS: (1) CONTROL & (3) STANDARD
GC GC
GC GC
NEXTORE NEXTORE
- -
- -
TYCO TYCO
SIM.
1
ALUMINUM FRAMED
DOOR W/ GLASS
KAWNEER
190 NARROW STILE W/
10" BOTTOM RAIL
ANODIZED ALUMINUM
NONE
HARDWARE: PUSH-CP, PULL-CS-9 (ARCHITECT'S CLASSIC) 190-10"
CONTINUOUS BOTTOM DOOR RAIL. NOTE: THUMBTURN LOCK TO
HAVE LOCKED OR UNLOCKED INDICATOR
DESCRIPTION MFR. MDL # / COLOR ALTERNATE REMARKS
DOOR HARDWARE SCHEDULE
NOTE: ALL SPECS MAY NOT BE USED IN EVERY STORE
GENERAL NOTE: FOLLOW ALL MANUFACTURERS
INSTALLATION AND MAINTENANCE INSTRUCTIONS
BEST ACCESS
(317) 849-2250
STANLEY HARDWARE
(800) 622-4393
IVES
(877) 671-7011
"CLASSROOM" BEST ACCESS SYSTEMS
93K-7-R-15-D-STK
FINISH - US26D
SCHLAGE
KEY OPERATED ON OUTSIDE ONLY
BUTT HINGES (1-1/2 PAIR
PER DOOR)
STANLEY HARDWARE
FBB-179, 4-1/2" x 4-1/2"
FINISH - US26D
HAGER HINGE CO
SOLID CORE WOOD
DOORS /
PL-LAM DOORS
COMMERCIAL DOOR
& HARDWARE
SEE DOOR SCHEDULE
SUBSTRATE ADHESIVE TO HAVE A VOC LIMIT
OF 30 g/L LESS WATER NO ADDED UREA-
FORMALDEHYDE RESINS FSC WOOD
HOLLOW METAL DOORS
& FRAMES
SEE DOOR SCHEDULE
WALL BUMPERS IVES
#407-1/2" CONCAVE
ALUM SILVER
BROOKLINE #1326-CV
CONCAVE
FLOOR STOPS IVES #436 ALUM SILVER BROOKLINE #1330A
COMMERCIAL DOOR
& HARDWARE
CONTACT
COMMERCIAL DOOR
(865) 429-8980
8
BEST ACCESS
(317) 849-2250
INTERIOR LOCK CORES BEST ACCESS SYSTEMS 9K SERIES
NONE
CONSTRUCTION CORE PROVIDED AT PUNCH
5-LCM17-A101-REV00
ACCESS PANEL ACUDOR #Z91818SCWHEQUAL
18" X 18" ACCESS PANEL - PAINT PER WALL
FINISH ACCESS PANEL RESIDES.
HOME DEPOT
FIXTURE - FLOOR
PLAN
A100
1
5/17/2017 OWNERS COMMENTS
Seal
ByDateMark
Revisions:
a
ap
p
4000 Luxottica Place, Mason, OH 45040
6 Creamery Brook, East Granby, CT 06026
+1 (513) 765-6000
+1 (516) 393-2484
SheetDate
Drawn By
Checked By
Title
ISSUED FOR:
Nextore project
Number
Client Review
DOB Permit
DOB Permit - Re-Submit
Bid
Construction
LL Approval
Brand Design Type:
Construction for:
Nextore Store Design Revision No.:
DESIGN & CONSTRUCTION
MANAGEMENT:
74149
DESIGN REV 01
MODULAR
11/9/2017
STAFF
STAFF
4000 Luxo
ttica Place M
aso
n, O
hio
45040
A Sub
sid
iary o
f the Luxo
ttica G
ro
up
Architect / Engineer Job No.:
LCM 012
Architect of Record
2
11/10/2017 OWNERS COMMENTS
CONSTRUCTION - FLOOR PLAN
SCALE: 1/4" = 1'-0"
1
A. GC TO MAINTAIN ALL DIMENSIONS AS SPECIFIED. NOTIFY NEXTORE PROJECT MANAGER OF ANY
DISCREPANCIES OF HOLD DIMENSIONS.
B. GC IS RESPONSIBLE FOR ANY PREPARATION OF THE FLOOR SLAB AND PROCUREMENT OF MATERIALS
REQUIRED AT THE PERIMETER TO PRODUCE A FLUSH CONDITION BETWEEN THE LENSCRAFTERS FLOOR
AREA AND THE EXISTING AREA FLOORING SURROUNDING.
C. GC IS RESPONSIBLE FOR INSTALLING ALL FINISH FLOORING. GC IS ALSO RESPONSIBLE FOR ALL FINISH
WALL MATERIALS BEHIND AND UNDER ALL MILLWORK.
D. GC SHALL SUPPLY AND INSTALL BLOCKING IN ALL WALLS AS REQUIRED TO SUPPORT WALL SHELVING
AND CABINETS. ANCHOR BLOCKING W/ SCREWS AT TOP MIDDLE AND BOTTOM (NO SILICONE). REFER TO
DWG. A200 & A201 AND MILLWORK SHOP DRAWINGS FOR MOUNTING HEIGHTS.
E. ADEQUATE ACCESS PANELS OR DOORS SHALL BE INCORPORATED INTO TENANT WORK FOR INSPECTION
SERVICE AND REPLACEMENT OF BOTH LANDLORD AND TENANT EQUIPMENT, COORDINATE PLACEMENT
WITH LANDLORD'S ON-SITE REPRESENTATIVE.
F. REFER TO SPECIFICATIONS (UNDER SEPARATE COVER) CONSTRUCTION CRITERIA MANUAL
G. NO MATERIAL SUBSTITUTIONS WILL BE PERMITTED UNLESS SUBMITTED TO NEXTORE PROJECT MANAGER
FOR REVIEW AND APPROVAL.
H. ALL MANUFACTURERS RECOMMENDED INSTALLATION AND MAINTENANCE PROCEDURES ARE TO BE
FOLLOWED BY GENERAL CONTRACTOR ON THIS PROJECT.
I. GENERAL CONTRACTOR IS RESPONSIBLE FOR CONTACTING THE REPRESENTATIVE LISTED AS SOON AS
CONTRACTS ARE AWARDED TO COMMUNICATE DESIRED SCHEDULE DATES AND PROJECT INFORMATION.
J. GENERAL CONTRACTOR IS RESPONSIBLE FOR ANY AND ALL UPCHARGES ASSOCIATED WITH THE DELAY
OF ORDERING SPECIFIED PRODUCTS.
K. ANY QUESTIONS CONCERNING THESE SPECIFICATIONS SHALL BE DIRECTED TO THE PROJECT MANAGER
FOR DOCUMENT CLARIFICATION.
L. ALL TENANT FURNISHED ITEMS (MATERIAL AND LABOR) TO BE SCHEDULED, COORDINATED & SUPERVISED
BY GC.
M. ALL DIMENSIONS ARE TO FACE OF GYP. BD. UNLESS NOTED OTHERWISE ON PLANS.
N. ALL GYP. WALL BOARD TO BE FINISH LEVEL 4. CEILING GYP. TO BE LEVEL 5 FINISH.
O. PRIOR TO INSTALLATION OF NEW FLOOR, GC TO VERIFY EXISTING FLOOR CONDITIONS MEETS AND ARE
IN COMPLIANCE WITH ANSI STANDARD FOR THIN SET TILE AND THE LATEST EDITION OF TILE COUNCIL OF
AMERICA. IF THERE ARE ISSUES OR DEFICIENCIES, CONTACT NEXTORE PROJECT MANAGER PRIOR TO
INSTALLATION.
EXIST. C.M.U. WALL
METAL FRAME DOOR
DOOR: REFER DOOR
DOOR: REFER DOOR
SCHEDULE
METAL FRAME DOOR
JAMB
METAL STUD WALL WITH
PAINTED GYPSUM
BOARD BOTH SIDES
NEW C.M.U. FILL WITH
BACKER ROD AND
SEALANT. PAINTED/
FINISHED TO MATCH
EXISTING
FURRING AS DETAILED W/
GYPSUM BOARD
SCHEDULE
JAMB
FRAME DETAILS
1
INTERIOR DOOR
3
EXTERIOR DOOR
DOOR TYPES
4
CASED OPENING
METAL STUD WALL WITH
PAINTED GYPSUM
BOARD BOTH SIDES
3/4" HARDWOOD
PAINTED
3/4"
3/4"
SOLID CORE WOOD
DOOR (FLUSH), DOOR
PAINTED PL105, FRAME
PAINTED P104.
SEE PLAN FOR
DIRECTION OF SWING
BA
6'-8"
4'-0" F.O.
A101
4
A101
1
CASED OPENING
T102T
(PAINTED/P104)
9'-3 7/8" F.O
.
4'-1
1
2
" R.O. HOLD
9'-4 5/8" R
.O
. H
OLD
WHEN CASED OPENING
ABUTTS WALLTILE
C
4'-0" F.O.
CASED OPENING
T102T
(PAINTED/P104)
9'-2 7/8" F.O
.
4'-1
1
2
" R.O. HOLD
9'-3 5/8" R
.O
. H
OLD
WHEN CASED OPENING
ABUTTS WALL COVERING OR PAINT
MARK DOORS HARDWAREFRAMES
WIDTH HEIGHT THICK TYPE CONSTRUCT FINISH
MATERIAL
GLAZING LABELCOLOR
FINISH LABEL
HEAD
DESCRIPTION CLOSER THRESHOLD STOP KICK
JAMB
DOOR SIZE DOOR DESCRIPTION
ROOM NAME
101ACASED OPENING
EXAM ROOM
102 NONONONE NO3'-0" 6'-8" 1 3/4" B SOLID CORE NONE NONE HM- P104PL105
REMARKS
14'-0" 9'-4 5/8" FINISHED CASED OPENING MATERIALS BY G.C.
1 LEVER/CLASS-RM
FLR
A
101CCASED OPENING
4'-0" 9'-3 5/8"
C
MACY'S
103 YESNONONE NOAS REQ. AS REQ. 1 3/4" D SOLID CORE NONE NONE HM-
2 LEVER/CLASS-RM
FLR
D
AS R
EQ
.
3'-6"
LO
CKSET
SEE
REMARK
SEE
REMARK
MACY'S DOOR ONLY
SEE REMARKS FOR
HARDWARE IN DOOR
SCHEDULE
SEE PLAN FOR
DIRECTION OF SWING
DOOR HANDLE - MFG.: TRILOGY MDL NO.: T2-DL 2700 IC/26D
HINGES - MFG.: STANLEY MDL NO.: FB-179 (3 PER DOOR)
FLUSH BOLT WHERE REQUIRED MDL. NO.: IVES 458B26D
GC TO VERIFY W MACY'S ON-SITE OPERATIONS FOR DOOR
FINISH TO MATCH
DOOR SCHEDULE
A101
4
A101
1
2
3
6
4'-0"
1
N
O
T
U
S
E
D
2-LCM17-A101-REV00
6-LCM17-A101-REV00
3-LCM17-A101-REV00
4-LCM17-A101-REV00
1. COAT HOOK PROVIDED AND INSTALLED BY GC. MOUNT AT 48" A.F.F. INTERIOR SIDE OF REFRACTION ROOM DOOR.
2. SEE ELEVATIONS FOR LOCATION OF WALL TILE FINISH.
3. SEE ELEVATIONS FOR BASEBOARD LOCATION AND STYLE.
4. NEW STUB-UP CONDUITS, REFER TO ELECTRICAL DRAWINGS FOR EXACT LOCATION FOR UTILITIES AND FREESTANDING
MILLWORK AND TRENCHING.
5. GC TO PROVIDE AND INSTALL CORNER GUARDS AT ALL BACK OF HOUSE OUTSIDE WALL CORNERS. SEE FINISH
SCHEDULE FOR MAKE AND MODEL.
6. GC TO PROVIDE & INSTALL ACCESS PANEL. PAINT TO MATCH WALL.
7. EXISTING PARTITION. G.C. TO PATCH/REPAIR AS REQUIRED TO MAINTAIN REQUIRED FIRE RATING.
8. REFER TO PLUMBING DRAWINGS FOR MOUNTING OF WATER HEATER AND SPECIFICATIONS.
9. NEW ELECTRICAL DISTRIBUTION EQUIPMENT, REFER TO ELECTRICAL DRAWINGS.
10. GYP. BD. BULKHEAD ABOVE.
11. RECESSED RECEPTACLE, COORDINATE WITH ELECTRICAL DRAWINGS.
12. WRAP COLUMNS AS INDICATED.
13. INFILL WALL AS REQUIRED. MATCH ADJACENT WALL CONSTRUCTION AND RATING. PREP WALL TO RECEIVE NEW
FINISHES.
14. EXISTING PARTITIONS AND COLUMN ENCLOSURES WITH-IN LEASE AREA TO BE PATCHED AND REPAIRED UPON ALL
NEW WORK TO A LEVEL 4 FINISH. (TYP)
15. PROVIDE NEW VENEER LAYER OF
5
8
" GYP. BD. ALONG ALL EXISTING WALLS WITH RECESSED STANDRADS. PROVIDE A
LEVEL 4 FINISH TYP).
16. PROVIDE AND INSTALL NEW PARTITIONS AS DIMENSIONED. PROVIDE AND INSTALL ALL DOORS AND/OR CASED
OPENINGS AS SPECIFIED.
17. PROVIDE AND INSTALL FLOOR MOUNTED SEWAGE EJECTION PUMPS. SEE PLUMBING DRAWINGS FOR SPECIFICATIONS.
18. PROVIDE 14" X 24" FLUSH ACCESS PANELS AT SANITARY PUMP LOCATIONS. G.C. TO PAINT PANEL TO MATCH
SURROUNDING WALL.
19. PROVIDE 18" X 18" FLUSH ACCESS PANELS AT SANITARY PUMP LOCATIONS. G.C. TO PAINT PANEL TO MATCH
SURROUNDING WALL.
20. LOCATION OF HAND WASH SINKS. REFER TO PLUMBING DRAWINGS FOR SPECIFICATIONS, AND WATER HEATER
MOUNTING OF AND SPECIFICATIONS.
21. PROVIDE AND INSTALL NEW MACY'S STOCKROOM DOOR. COORDINATE WITH MACY'S REPRESENTATIVE FOR FINAL
DOOR LOCATION PRIOR TO CONSTRUCTION.
#
1
KEYED NOTES
1-LCM17-A101-REV00
GENERAL NOTES - CONSTRUCTION4
CLG. HT.=
PRETEST
102
10'-0"
CLG. HT.=
CONTACT LENS /
OPTICAL STATION
104
10'-0"
CLG. HT.=
REFRACTION
ROOM
101
10'-0"
CLG. HT.=
RETAIL SALES AREA
100
10'-6 1/2"
24'-8"31'-11 1/2"
CLG. HT.=
OD RECEPTION
/ WAITING
103
8'-0"
TRUE NORTH PLAN NORTH
2
14
16
NOTE: REFERENCE INTERIOR
ELEVATIONS FOR REQUIRED
IN WALL BLOCKING
MA
CY'S R
ETA
IL A
REA
LEASE LINE
102
4
MACY'S RETAIL AREA
LEASE LINE
LEASE LINE
EXTERIOR
EN
TR
Y V
ESTIBU
LE
EXTERIOR
MACY'S RETAIL AREA
8'-0" (H
OLD
)
4 7/8"
4 7/8"
4'-1 1/2" G
YP. BD
.
R.O
. (H
OLD
)
A500
1
10
101C
A500
5
N
O
T
U
S
E
D
A500
6TYP. OPP.
FIELD
D
ET.
EQ
UA
LEQ
UA
L
CEN
TER
LIN
E V
ID
EO
W
ALL
11
3
SIM.
LA
YO
UT
PO
IN
T
3
3 14 16
A300
4
A300
4
A300
4
A300
2
A300
2
3 14 16
4 1/4"
12'-0" (HOLD)
8'-7 1/2"
4 7/8"
8 20
8 20
4 1/4"
4 7/8"
2'-6"
5
1
5
3
3
3
11
LAYOUT
POINT
A300
5
SIM.
9
3
N
O
T
U
S
E
D
E
A101
3
OD ENTRY
104 NOYESNONE3'-0" 7'-0" +/-1 3/4" E ALUM. GLASS TEMPERED NONE ALUM.ANODIZED ALUM.3/A101 SEE SCHEDULE
HINGENOTE: SEE PLAN DETAIL 3/A101 TO DETERMINE IF CLOSER
CAN BE INSTALLED.
1 1/2"
4 7/8"
EXISTING
STORM/SANITARY
NOTE: INSTALL
LAYER OF GYP. BRD.
AS/IF REQUIRED TO
PROVIDE SMOOTH
SURFACE ALIGNING
WITH CEILING
TRANSITION ABOVE
(AS SHOWN)
A300
5
SIM.
A300
5
7
LA
YO
UT
PO
IN
T
5
1 2
"
LA
YO
UT
PO
IN
T
4 7/8"
1'-11"
4'-2" 4 7/8"
104
A101
3
NOTE: G.C. TO INSTALL FRAMING ABOVE
NEW LAY-IN CEILING THIS AREA FOR
SUSPENSION OF LAY-IN CEILING, LIGHTING,
DUCTWORK, ETC. FRAMING REQUIRED DUE
TO EXISTING WALL DUCTWORK (ABOVE) THIS
AREA. SEE FRAMING PLAN DETAIL 2/A101.
SEE DR.
FINISHED CASED OPENING MATERIALS BY G.C.
4
YES
1
NOTE: REFERENCE DOOR HARDWARE SCHEDULE ON SHEET A-100
1
NOTE: REFERENCE DOOR HARDWARE SCHEDULE ON SHEET A-100
1
4 7/8" 6'-0 3/4" 4 7/8"
F.D.
(+/-4'-8")4 7/8"
4 7/8"
(4'-6 1/2"
MIN.
REQUIRED)
3
'-8
1
/2
"
M
IN
.
6'-0 1/2"
VERIFY W/
SHP. DWGS
5'-0 1/2"
6'-10 1/2" H
OLD
2'-10 1/2"
2'-7"
LAYOUT NOTE: FLOOR FIXTURE THIS AREA
TO BE LOCATED DURING FRAMING LAYOUT
STAGE SO AS TO VERIFY MINIMUM
DIMENSION IS PROVIDED AS SHOWN.
NOTE: REFERENCE DOOR HARDWARE
SCHEDULE ON SHEET A-100
2
10"
2
PROVIDE DOUBLE STUDS
AT EACH END OF METAL
FRAMING (TYP.) (3 5/8"-18
GA. MIN.)
STRUCTURE FOR INSTALL
OF LAY-IN CEILING,
LIGHTS, DUCTWORK, ETC.
A
A
B
4'-0" O.C.
MAX. TYP.
F.D.
(2) 6" X
18 G
A. M
TL
HEA
DER
(BA
CK TO
BA
CK)
TYPIC
AL
(2) 6" X 18 GA. METAL
JOIST BOX BEAM
BTM
. A
T
+/-9'-10"
BTM
. A
T
+/-11'-3"
BTM
. A
T
+/-11'-3"
BTM
. A
T
+/-11'-3"
C
SECTION
SCALE: N.T.S.
A
CLG. WIRE @ 4'-0" O.C.
THRU HOLES IN
PUNCHED STUDS
(2) 6"-18 GA. METAL HEADER
(2) #10 TEK SCREWS @
12" O.C.
SECTION
SCALE: N.T.S.
B
(2) 3 5/8"-18 GA. METAL STUDS
w/ #10 TEK SCREWS @ 6" O.C.
STAGGERED
16 GA. FRAMING CLIP w/ (2) #10
TEK SCEWS EA. LEG
(2) #10 TEK SCREWS @ 12" O.C.
CLG. WIRE @ 4'-0" O.C. THRU
HOLES IN PUNCHED STUDS
16 GA. FRAMING CLIP w/ (2) #10
TEK SCEWS EA. LEG
(2) #10 TEK SCREWS @ 12" O.C.
CLG. WIRE @ 4'-0" O.C. THRU
HOLES IN PUNCHED STUDS
(2) 6" X 18 GA. STEEL JOISTS WITH
16 GA. TRACK (TOP AND
BOTTOM)
SECTION
SCALE: N.T.S.
C
(2) #10 TEK
SCREWS @ 16" O.C.
(BOTH SIDES)
SEALANT / CAULK &
BACKER ROD AS
REQUIRED. (COLOR
TO MATCH
ADJACENT FINISH).
TYP.
5/8" TYPE X GYP. BRD. OVER
3 5/8" X 20 GA. METAL
FRAMING AT 16" O.C.
VESTIBULE
LENSCRAFTERS OD
AREA
1'-0 1/2"
MIN.
REQUIRED
F.D
.
+/-2"
MIN.
EXISTING
STRUCTURE
EXISTING
CONSTRUCTION
TO REMAIN
STAINLESS STEEL CORNER GUARD
(TYP. OPP.)
GYP. BRD. (WALL AND CEILING)
AND WALL BASE THIS AREA TO
MATCH MACY'S (TYP. THIS AREA)
GYP. BRD. SOFFIT TO ALIGN WITH
EXISTING HORIZ. METAL REVEAL.
SEE ELEVATION
EXISTING CONSTRUCTION
TO REMAIN
EXISTING
STRUCTURE
INSTALL NEW BEARING STUDS
AND HEADER FRAMING AS
REQUIRED FOR EXISTING
FRAMING ABOVE THIS AREA TO
REMAIN
(2) 3 5/8" X 18 GA. BEARING
STUDS (TYP. OPP.)
NEW ENTRY
DOOR. SEE DOOR
SCHEDULE
NOTE:
-A 1'-0" MINIMUM DIMENSION IS REQUIRED ON PUSH SIDE THIS AREA FOR CLOSER TO BE INSTALLED ON DOOR.
-DURING DEMOLITION / WITHIN (2) DAYS OF START OF CONSTRUCTION G.C. TO FIELD VERIFY DIMENSION THIS AREA
CONSTRUCTION
FLOOR PLAN
A101
1
5/17/2017 OWNERS COMMENTS
Seal
ByDateMark
Revisions:
a
ap
p
4000 Luxottica Place, Mason, OH 45040
6 Creamery Brook, East Granby, CT 06026
+1 (513) 765-6000
+1 (516) 393-2484
SheetDate
Drawn By
Checked By
Title
ISSUED FOR:
Nextore project
Number
Client Review
DOB Permit
DOB Permit - Re-Submit
Bid
Construction
LL Approval
Brand Design Type:
Construction for:
Nextore Store Design Revision No.:
DESIGN & CONSTRUCTION
MANAGEMENT:
74149
DESIGN REV 01
MODULAR
11/9/2017
STAFF
STAFF
4000 Luxo
ttica Place M
aso
n, O
hio
45040
A Sub
sid
iary o
f the Luxo
ttica G
ro
up
Architect / Engineer Job No.:
LCM 012
Architect of Record
2
11/10/2017 OWNERS COMMENTS
FRAMING PLAN
SCALE: 1/4" = 1'-0"
2
OD ENTRY DOOR DETAIL
SCALE: 1" = 1'-0"
3
REFLECTED CEILING PLAN
SCALE: 1/4" = 1'-0"
1
A. EMERGENCY (EM) LUMINAIRES SHALL BE CIRCUITED WITH AN "UNSWITCHED HOT" TO PROVIDE
CONTINUOUS POWER TO BATTERY PACK EVEN WHEN LUMINAIRE IS OFF.
B. ALL NIGHT-LIGHT (NL) LUMINARES SHALL BE CIRCUITED AHEAD OF ANY SWITCHING
C. IT SHALL BE THE G.C.'S RESPONSIBILITY TO UNLOAD INVENTORY AND STORE LIGHTING PACKAGE. THE G.C.
SHALL ALSO SHIP ANY EXCESS MATERIALS BACK TO THE ELECTRICAL PACKAGE DISTRIBUTOR.
D. EXIT LIGHTS AT THE STOREFRONT SHALL BE CEILING MOUNTED AND CENTERED OVER OPENINGS.
EXIT/EMERGENCY LIGHTS AT DOOR TO NON-SALES AREAS SHALL BE CEILING MOUNTED AND CENTERED
ABOVE DOOR. IF PLAN LOCATIONS ARE NOT ACCEPTABLE, IMMEDIATELY CONTACT NEXTORE PROJECT
MANAGER FOR DIRECTION.
E. WHERE DRYWALL CEILINGS ARE USED IN THE SALES AREA, G.C. SHALL ARRANGE CIRCUITS TO AVOID THE
USE OF JUNCTION BOXES IN INACCESSIBLE LOCATIONS. THE USE OF JUNCTION BOXES ABOVE DRYWALL
CEILINGS SHALL BE LIMITED TO LOCATIONS NEAR ACCESS FRAMES USED FOR DIFFUSERS AND RETURN AIR
GRILLES OR ACCESS PANELS AS LOCATED ON PLANS. IF PLAN LOCATION IS NOT ACCEPTABLE,
IMMEDIATELY CONTACT NEXTORE PROJECT MANAGER FOR DIRECTION.
F. G.C.'S BID SHALL INCLUDE THE INSTALLATION OF ALL LUMINARES AND ASSOCIATED LAMPS FURNISHED BY
NEXTORE. G.C. IS RESPONSIBLE TO ENSURE THE ADJUST ABILITY OF ALL DIRECTIONAL FIXTURES AFTER
INSTALLATION AND SHALL AIM THE FIXTURES PER DIRECTION FROM G.C. LIGHT FIXTURE SPECIFICATIONS
MAY VARY, IF THIS IS THE CASE, CONTRACTOR SHALL CALL THE LIGHTING DISTRIBUTOR FOR EXACT
SPECIFICATION OF LIGHTING FIXTURES. IF THE CEILING SYSTEMS ARE FIRE RATED, G.C. SHALL CLOSELY
COORDINATE FIXTURE REQUIREMENTS WITH NEXTORE.
G. G.C. SHALL MAKE ALL FINAL CONNECTIONS AS REQUIRED FOR A FULLY COMPLETE AND OPERABLE SYSTEM.
H. G.C. SHALL VERIFY THE VOLTAGE AND COMPATIBILITY OF ALL EQUIPMENT, FIXTURES AND MILLWORK
PRIOR TO CONNECTION.
I. CEILING GRID SHALL BE CENTERED IN ROOM UNLESS OTHERWISE NOTED.
J. DOWN LIGHTS SHALL BE CENTERED IN TILE UNLESS OTHERWISE NOTED.
FOR NEW FIRE SPRINKLER SYSTEM:
CONTRACTOR SHALL PROVIDE A COMPLETE FIRE PROTECTION SPRINKLER SYSTEM FOR THE ENTIRE SPACE IN
COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS AND THE LANDLORD'S CRITERIA. THE
CONTRACTOR SHALL HAVE DRAWINGS, SHOP DRAWINGS, APPLICATIONS AND SUBMITTALS PREPARED BY A
PROPERLY LICENSED PROFESSIONAL, WHO IS APPROVED BY THE LANDLORD. ALL DRAWINGS AND
CONSTRUCTION SHALL BE IN COMPLIANCE WITH ALL CODES, REGULATIONS, INSURANCE ASSOCIATIONS AND
RATING BUREAUS AND SHALL INCLUDE ALL PERMITS, TESTS, SHUT DOWN FEES AND CERTIFICATIONS TO PROVIDE
A COMPLETE IN PLACE SYSTEM.
FOR EXISTING FIRE SPRINKLER SYSTEM:
CONTRACTOR SHALL REWORK AND MODIFY THE SYSTEM IF NECESSARY FOR THE NEW SPACE CONFIGURATION.
MODIFICATIONS SHALL BE DESIGNED AND INSTALLED BY A QUALIFIED FIRE SPRINKLER CONTRACTOR, WHO
SHALL PREPARE DESIGN/SHOP DRAWINGS OF THE SYSTEM AND SUBMIT SUCH DRAWINGS TO THE LANDLORD
AND BUILDING AND FIRE DEPARTMENTS FOR APPROVAL PRIOR TO FABRICATION AND INSTALLATION. ALL WORK
SHALL BE DONE IN ACCORDANCE WITH NFPA, STANDARD 101, AND ANY OTHER STATE OR LOCAL CODES
HAVING JURISDICTION.
DESIGN STANDARDS:
- HARD CEILING AND CEILING TILE AT RETAIL AREA / STOREFRONT: WHITE CONCEALED HEADS; RELIABLE
MODEL 'G-4'; TYCO 'RF-11'
- CEILING TILE AT OD, AND LENS PROCESS: RECESSED WHITE PENDANT HEADS WITH WHITE TRIM RINGS;
RELIABLE MODEL "G-F1'; TYCO 'TY-L'
- CEILING TILE AT LOUNGE, OFFICE, AND BACK OF HOUSE: WHITE PENDANT HEADS WITH WHITE TRIM RINGS;
RELIABLE MODEL "G"; 'TY-L'
SPRINKLER SYSTEM NOTES
#
KEYED NOTESGENERAL NOTES
OD AREA ONLY
SYMBOL TYPE DESCRIPTION
AD- EM
RECESSED 2X2 LED TROFFER WITH EMERGENCY BATTERY
BACKUP.
X2
RECESSED EXTRUDED ALUMINUM EDGE LIT EXIT SIGN WITH
RED LETTERS FOR CEILING OR WALL MOUNTING RED LED
INCLUDED. TO BE RECESSED MOUNTED U.N.O. (FOR NYC
OR CHICAGO CONFIRM WITH MANUF). PROVIDE
CURRENT LIMITER WHERE REQUIRED.
X2
2T-S
LIGHTING SCHEDULE
TL
2T-S
4T-S
6T-S
8T-S
AD RECESSED 2X2 LED TROFFER
AD
2 FT LONG, SINGLE CIRCUIT, WHITE TRACK
TL
GIMBAL STYLE LAMP-HOLDER, WHITE
4T-S
4 FT LONG, SINGLE CIRCUIT, WHITE TRACK
TL
GIMBAL STYLE LAMP-HOLDER, WHITE
6T-S
6 FT LONG, SINGLE CIRCUIT, WHITE TRACK
TL
GIMBAL STYLE LAMP-HOLDER, WHITE
8T-S
8 FT LONG, SINGLE CIRCUIT, WHITE TRACK
TL
GIMBAL STYLE LAMP-HOLDER, WHITE
12T-S 12T-S
12 FT LONG, SINGLE CIRCUIT, WHITE TRACK
TL
GIMBAL STYLE LAMP-HOLDER, WHITE
TL
TL
TL
TL
SEE ELEC. SHEETS FOR MFG,
SPECS ETC.
(TYP. ALL LIGHTS IN
SCHEDULE)
AD-EM
CEILING SYMBOLS
1 2
3 4
5
DESCRIPTION
1. EXISTING CEILING IN THE RETAIL AREA IS THE EXISTING MACY'S CEILING TO REMAIN, PATCH GRID
INTO NEW WORK AND REPLACE ANY DAMAGED OR STAINED TILES WITH NEW TO MATCH EXISTING..
2. EXISTING GYP. BD. CEILING IN THE RETAIL AREA. EXISTING MACY'S CEILING TO REMAIN.
3. SEE SHEET A101 CONSTRUCTION FLOOR PLAN AND ELEVATIONS FOR BULKHEAD HEIGHT
4. PROVIDE AND INSTALL NEW 2X2 ACOUSTICAL CEILING IN THE OD AREA. SEE FINISH SCHEDULE SHEET A103.
5. EXISTING LIGHTING IN THE RETAIL AREA IS THE EXISTING MACY'S LIGHTING TO REMAIN. CLEAN AND
RELAMP.
6. INSTALL PROVIDED 2 X 2 LED LIGHTING TYPE "AD" AND "AD-EM".
7. INSTALL PROVIDED SECTIONS OF TRACK "XT-S" AND LIGHTING FIXTURES "TL" AS SHOWN.
8. INSTALL PROVIDED EXIT LIGHTING TYPE "X2".
9. EXISTING HVAC DIFFUSERS IN THE RETAIL AREA ARE EXISTING MACY'S TO REMAIN, CLEAN.
10. NEW HVAC DIFFUSERS IN OD ROOMS. SEE MECHANICAL
11. EXISTING EMERGENCY LIGHTING IN THE RETAIL AREA TO REMAIN. FIELD VERIFY FIXTURES ON EMERGENCY
GENERATOR
12. EXISTING SPEAKERS, SECURITY CAMERAS, TO REMAIN.
13. SPRINKLER HEADS FOR REFERENCE ONLY WHEN SHOWN
1-LCM17-A102-REV00 2-LCM17-A102-REV00
3-LCM17-A102-REV00
4-LCM17-A102-REV00
HVAC AIR DEVICES SHOWN FOR REFERENCE AND
COORDINATION. REFER TO MECHANICAL PLANS FOR MORE
INFO.
SUPPLY
RETURN
SPRINKLER HEAD
RETURN
24"X24"12"X24"
5-LCM-A102-REV 0.1
EX1
EX4
EX4
EX4
EX4 EX4
EX1
EX1
EX1
EX1 EX1
EX2EX2
EX2
EX2
EX2
EX2
EX2
EX1EX1
EX4 EX4 EX4
EX4 EX4
EX4 EX4EX4 EX4
EX4
EX4
EX4
EX4
EX4
EX4
EX4
EX2
EX4
EX4
EX4EX4
EX4
EX4
EX4
EX4
EX4
CLG. HT.=
PRETEST
102
10'-0"
CLG. HT.=
CONTACT LENS /
OPTICAL STATION
104
10'-0"
CLG. HT.=
REFRACTION
ROOM
101
10'-0"
CLG. HT.=
RETAIL SALES AREA
100
10'-6 1/2"
ADAD
AD AD
AD
TL
6T-S
TL
TL
TL
TL
TL
TL
TL
TL
TL2TL2
TL2
TL2
TL2
AD
6T-S
6T-S
TL
TL
CLG. HT.=
OD RECEPTION
/ WAITING
103
8'-0"
EX
3
EX
3
AD-EM
2
T
-
S
T
L
T
L TL2
TRUE NORTH PLAN NORTH
NOTE: EXISTING SPRINKLER HEADS AT THE NEW LAY-IN
CEILING AREAS ARE TO BE RELOCATED. FIELD VERIFY
EXISTING CONDITIONS TO DETERMINE SCOPE OF
WORK. REFERENCE DEMOLITION REFLECTED CEILING
PLAN FOR ADDITIONAL INFORMATION
EMERGENCY LIGHTING NOTE: PRIOR TO FINAL INSPECTION G.C. TO SCHEDULE ON SITE MEETING WITH
LOCAL BUILDING AND OR FIRE MARSHALL TO CONDUCT TEST OF EXIT SIGNS AND EMERGENCY LIGHTING
SYSTEM. MODIFICATIONS TO EXIT SIGNS AND EMERGENCY LIGHTING SYSTEM ARE TO BE MADE AS / IF
REQUIRED AS A RESULT OF THIS TEST. ANY CHANGES ARE TO BE REVIEWED AND APPROVED BY NEXTORE
PROJ. MGR..TENANT G.C. TO PROVIDE WRITTEN DESCRIPTION OF TEST RESULT (AND DESCRIPTION OF
PROPOSED CHANGES IF REQUIRED) TO NEXTORE PROJECT COORDINATOR AND ARCHITECT OF RECORD.
TEST TO BE SCHEDULED IN ADVANCE OF PROJECT TURNOVER SO AS TO ALLOW SUFFICIENT TIME FOR ANY
CHANGES TO BE MADE.
NOTE: REFER TO DETAIL A/A300 FOR LAY-IN CEILING
SUSPENSION GRID AND LIGHT FIXTURE SUPPORT
DETAIL (TYPICAL)
5 9 11
12 13
NEW
LIG
HT TR
AC
K A
ND
H
EA
DS
LEASE LINE
LEASE LINE
ILLUMINATED SIGN. SEE
ELEVATIONS AND ELECT.
DWGS
1
3
9'-2 3/4"
6
9
AC-4C4
AC-4C
4
7
EXISTING
CLG. HT. = 10'-6 1/2"
4'-0"
FULL
TILE
F.D
.
EQ
.EQ
.
EQ. EQ.
EQ
.EQ
.
6
66
6
6
6
AC-4C4
LEASE LINE
7
7
EXISTING RECESSED DOWN LIGHTING
EXISTING EXIT SIGN
EXISTING SPRINKLER HEAD
EX4
SPKR
EX2
EXISTING RECESSED DOWN LIGHTING
EXISTING SPEAKER
CAMEXISTING CAMERA
EX1
EXISTING 2 X 2 FLUORESCENT
EXISTING STRIP FLUORESCENT
EXISTING LIGHTING SCHEDULE6
EX3
6
RELOCATED SPRINKLER HEAD
EX5
9
EQ.EQ.
10
10
10
EX6
EXISTING STRIP FLUORESCENT
TL2
MONOPOINT LIGHT FIXTURE
TL2
SHADING INDICATES EXISTING CEILING GRID
AND TILES TO BE BE PATCHED AND REPAIRED AS
REQUIRED DUE TO DEMOLITION THIS AREA
2
2
EXISTING
CLG. HT. = 10'-1"
INSTALL NEW "TL2" LIGHT
FIXTURES IN CENTER OF
CEILING TILE AS SHOWN
(TYP.)
EQ
.EQ
.
NEW TRACK LIGHTING.
INSTALL ON 45 DEG. AS
SHOWN
EQ
.EQ
.
EQ. EQ.
A102
2
8
X2
4'-0"
NOTE: G.C. TO INSTALL FRAMING ABOVE
NEW LAY-IN CEILING THIS AREA FOR
SUSPENSION OF LAY-IN CEILING, LIGHTING,
DUCTWORK, ETC. FRAMING REQUIRED DUE
TO EXISTING WALL DUCTWORK (ABOVE) THIS
AREA. SEE FRAMING PLAN DETAIL 2/A101.
NOTE: SHADING INDICATES LAY-IN
CEILING TO BE INSTALLED AT 8'-0" A.F.F.
SECTION
SCALE: 3" = 1'-0"
2
ACOUSTCAL CEILING
8'-0" A.F.F.
10'-0" A.F.F.
INSTALL TRANSITION
PER MANUF.
RECOMMENDATIONS
REFLECTED CEILING
PLAN
A102
1
5/17/2017 OWNERS COMMENTS
Seal
ByDateMark
Revisions:
a
ap
p
4000 Luxottica Place, Mason, OH 45040
6 Creamery Brook, East Granby, CT 06026
+1 (513) 765-6000
+1 (516) 393-2484
SheetDate
Drawn By
Checked By
Title
ISSUED FOR:
Nextore project
Number
Client Review
DOB Permit
DOB Permit - Re-Submit
Bid
Construction
LL Approval
Brand Design Type:
Construction for:
Nextore Store Design Revision No.:
DESIGN & CONSTRUCTION
MANAGEMENT:
74149
DESIGN REV 01
MODULAR
11/9/2017
STAFF
STAFF
4000 Luxo
ttica Place M
aso
n, O
hio
45040
A Sub
sid
iary o
f the Luxo
ttica G
ro
up
Architect / Engineer Job No.:
LCM 012
Architect of Record
2
11/10/2017 OWNERS COMMENTS
FINISH PLAN
SCALE: 1/4" = 1'-0"
1
MATERIAL FLAME SPREAD SMOKE DENSITY
95 (BONDED)80 (BONDED)PLASTIC LAMINATE
450 OR LESS26 - 75CARPET
450 OR LESS0.45VINYL TILE
1025LAY-IN CEILING
245150FRP
450 OR LESS0.45VINYL BASE
1. LINE OF PARTITION ABOVE (SHOWN DASHED.
2. NO TRANSITION STRIP AT PORCELAIN TILE. TILE TO BUTT UP TO MILLWORK.
COORDINATE STOPPING POINT OF PORCELAIN TILE WITH TENANT'S
MILLWORKER.
3. G.C. TO PATCH AND REPAIR EXISTING CONCRETE AS REQUIRED PER NEXTORE
PROJECT MANAGER'S APPROVAL. PREPARE CONCRETE AS REQUIRED FOR
NEW FLOOR FINISH. ENTIRE LEASED SPACE.
4. MACY'S FLOOR TILE. GC TO VERIFY W PM FOR SUPPLY AND INSTALL.
5. GC TO WRAP BASE AND WALLCOVERING AROUND WALL CORNER & INTO
3
4
"
QUIRK. PAINT REVEAL P117.
6. REFER TO INTERIOR ELEVATIONS FOR EXTENT OF WALLCOVERING.
7. WALL BASE SUPPLIED AND INSTALLED BY G.C. SEE DETAIL 3, SHEET A500.
8. G.C. TO INSTALL CORNER GUARD, CG-100, REFER TO THIS SHEET FOR
SPECIFICATION.
9. EXISTING MIRRORED COLUMNS WITH 4" BASE TO RECEIVE WB102.
10. WIDTH OF T102 MAY VARY DUE TO TRANSITION TO B.O.H.. MAINTAIN
3
4
"
EACH SIDE OF GYP. AT OPENING.
11. START TILE LAYOUT W HALF CARPET TILE AT TRANSITION. TRANSITION TO
OCCUR UNDER DOOR SIDE @ DOOR STOP.
12. NOTE DIRECTION OF CARPET TILE
#
KEYED NOTES
A. G.C. IS RESPONSIBLE FOR ANY PREPARATION OF THE FLOOR SLAB AND PROCUREMENT OF MATERIALS
REQUIRED TO PRODUCE A FLUSH CONDITION BETWEEN THE STORE LEASE LINE AND THE EXISTING
MALL FLOORING.
B. G.C. IS RESPONSIBLE FOR INSTALLING ALL FINISH FLOORING. G.C. IS ALSO RESPONSIBLE FOR ALL FINISH
MATERIALS BEHIND AND UNDER ALL MILLWORK.
C. REFER TO ARCHITECTURAL SPECIFICATIONS / FINISHES SCHEDULE THIS SHEET & REFER TO GENERAL
NOTES ON SHEET G100
D. ALL TENANT FURNISHED ITEMS (MATERIAL AND LABOR) TO BE SCHEDULED, COORDINATED AND
SUPERVISED BY G.C.
E. REFER TO DOOR SCHEDULE FOR DOOR FINISHES. GO TO PREP EXISTING DOORS PRIOR TO
RE-FINISHING.
F. PRIOR TO INSTALLATION OF NEW FLOOR, GC TO VERIFY EXISTING FLOOR CONDITIONS MEETS AND ARE
IN COMPLIANCE WITH ANSI STANDARD FOR THIN SET TILE AND THE LATEST EDITION OF TILE COUNCIL
OF AMERICA. IF THERE ARE ISSUES OR DEFICIENCIES, CONTACT NEXTORE PROJECT MANAGER PRIOR TO
INSTALLATION.
GENERAL NOTES - FINISH PLANFINISH SYMBOL KEY
= FLOOR
XXXXW
XXXXB
XXXXF
= BASE
= WALL
= CEILING (SEE RCP FOR
LOCATION)
XXXXC
3
XXXXT = TRIM
P101W
WB102B
C63F
INTERIOR MATERIALS
FIRE RATINGS
1 2 3
4
P101W
WB102B
PT108F
P114W
SEE SHEET A200 FOR ELEVATIONS
& FINISH EXTENTS
FU
LL TILE
1-LCM00-A103-REV00
4-LCM17-A103-REV00 2-LCM17-A103-REV00 3-LCM17-A103-REV00
WC105W
P101W
WB102B
PT108F
P114W
10
TS-10
10/A500
1
16
" GROUT JOINT
ITEM MARK DESCRIPTIONMFG./PHONE # MODEL #/COLOR
REMARKS
ARCHITECTURAL SPECIFICATIONS / FINISHES
NOTE: ALL SPECS MAY NOT BE USED IN EVERY STORE
GENERAL NOTE: FOLLOW ALL MANUFACTURERS INSTALLATION AND MAINTENANCE INSTRUCTIONS
WA
LLS
PAINT P101
PAINT (EGGSHELL) (EXTRA WHITE)
SHERWIN WILLIAMS(800) 474-3794
INTERIOR ACRYLIC LATEX
EXTRA WHITE, SW7006
INTERIOR WALLS AND SOFFITS
WB101 WOOD WALL BASE
PORCELAIN TILE PT108
LARGE FORMAT PORCELAIN TILE
24"x24"x10mm
NOREEN SCHERTLER
(312) 342-4689
ROADS; ITEM #P66201 - SQUARE GREY CALM, (MATTE FINISH)
GROUT: 1/16" THK., MAPEI #27 SILVER (NO SUBSTITUTIONS)
MANDATORY INSTALLATION PER MANUFACTURER'S
SPECIFICATIONS.
FLO
OR
IN
GC
EILIN
GM
ILLW
OR
K
ALUMINUM A-1 ALUMINUM TIGER(800) 898-4437 TIGER DRYLAC 49/80180
STOREFRONT GLAZING CHANNELS, 12' LENGTHS.
STOREFRONT BASE, & 2" REVEAL PROFILE.
PLASTIC LAMINATE PL100 PLASTIC LAMINATE WILSONART(800) 433-3222
FROSTY WHITE #1573-60 MATTE W/SOLID
COLOR CORE @ EXPOSED EDGES
MILLWORK
PLASTIC LAMINATE PL102 PLASTIC LAMINATE FORMICA
MICHAEL HERTENSTINER
(440) 668-7030
DECOMETAL COLLECTION
2022 BRUSHED ALUMINUM
MILLWORK
PLASTIC LAMINATE PL103 PLASTIC LAMINATE FORMICA
MICHAEL HERTENSTINER
(440) 668-7030
COLORCORE2 COLLECTION
7223C-58 NEW WHITE (MATTE)
MILLWORK
MILLWORK FINISH PC100 MILLWORK POWDERCOAT MATTHEWS PAINT
MP30136R11950 POWDERCOAT SOA V1.0
BRUSHED ALUMINUM
MILLWORK
ARCHITECTURAL
METAL TRIM
M102 METAL STYLMARK
NADINE KING
(763) 574-7474
RECTANGULAR TRIM #110672 W/ BASE
#412007 FINISH - 120
TRIM DETAIL FOR WALLCOVERING, 2-PART ASSEMBLY
MELAMINE MEL100 MELAMINE PANOLAM(800) 672-6652
S557 INTERNATIONAL WHITE / CRYSTAL
TEXTURE
MILLWORK
TR
AN
SITIO
N STR
IPS
TRANSITION STRIP TS-1TRANSITION STRIP (CARPET TO TILE)
JOHNSONITE
ROD SEABOLT
CDC DISTRIBUTORS
(513) 560 - 1040
PART # CCA-XX / #32 PEBBLE
FLAME SPREAD: ASTME-84 75 OR LESS, CLASS B SMOKE
DEVELOP:NA, FUEL CONTRIBUTED: NA
TRANSITION STRIP TS-2TRANSITION STRIP (CARPET TO CONCRETE)
JOHNSONITE PART # EG-XX-K / #32 PEBBLE
FLAME SPREAD: ASTME-84 75 OR LESS, CLASS B. SMOKE
DEVELOP:NA, FUEL CONTRIBUTED: NA
TRANSITION STRIP TS-4
TRANSITION STRIP (CARPET TO VINYL AND
CARPET TO PORCELAIN)
SCHLUTER
WWW.SCHLUTER.COM
1-800-472-4588
SCHIENE, MINIMAL HEIGHT AS APPROPRIATE FOR FLOORING
TRANSITION ALUMINUM (-A); 1/4" THICK EDGE.
ZINC STRIP AT OD AREA.
TRANSITION STRIP TS-9TRANSITION STRIP (PORCELAIN TO VINYL)
JOHNSONITE
ROD SEABOLT
CDC DISTRIBUTORS
(513) 560 - 1040
PART # CTA-XX-K / #32 PEBBLEBETWEEN PORCELAIN TILE & VINYL
TRANSITION STRIP TS-10
TRANSITION STRIP (PORCELAIN TO MALL TILE
FLOORING)
SCHLUTER
WWW.SCHLUTER.COM
1-800-472-4588
SCHLUTER - DECO, ALUMINUM (-A) HEIGHT AS APPROPRIATE
FOR FLOORING TRANSITION, 1/4" THICK ALUMINUM EDGE
BETWEEN RETAIL TILE AND EXISTING AISLE
TRANSITION STRIP TS-12TRANSITION STRIP (VINYL TO CONCRETE)
JOHNSONITE
ROD SEABOLT
CDC DISTRIBUTORS
(513) 560 - 1040
PART # RRS-XXC / #32 PEBBLE
FLAME SPREAD: ASTME-84 75 OR LESS, CLASS B SMOKE
DEVELOP:NA, FUEL CONTRIBUTED: NA
SEA
LER
PRIMER/SEALER LATEX PRIMER / SEALER FOR DRYWALL ICI DULUX PAINTS(502) 969-0181
# 1020-1200PVAONE (1) COAT REQUIRED
PRIMER/SEALER LATEX PRIMER / SEALER FOR METALICI DULUX PAINTS
(502) 969-0181DEVGUARD #4120
ONE (1) COAT REQUIRED
PRIMER/SEALER LATEX PRIMER / SEALER FOR WOODICI DULUX PAINTS
(502) 969-0181WOOD UNDERCOATER
ONE (1) COAT REQUIRED
FIN
ISH
ES
CHAIR RAIL
CR100 CHR-50-C
JOHNSONITE
ROD SEABOLT
CDC DISTRIBUTORS
(513) 560 - 1040
OD WAITING, EXAM & PRETEST (PER ELEVATIONS)
CORNER GUARD CG100
50 WHITE
VBG-50-A-48
VINYL CORNER GUARD
CHAIR RAIL
USE ON EXPOSED OUTSIDE CORNERS IN O.D. & B.O.H.
PORCELAIN TILE PT105PORCELAIN TILE (7 7/8" x 19 5/8" x 1/4" THK)
DESIGNER
TILE & STONE
ARCTYC, WHITE
GROUT: 1/16" THK., MAPEI #38 AVALANCHE
8 X 20
STOREFRONT PORTAL FRAME, INSIDE WD201. VERIFY W
ELEVATION
PAINT
PAINT (SEMI GLOSS) (EXTRA WHITE)DOOR FRAMES EVERYWHERESHERWIN WILLIAMS
(800) 474-3794
INTERIOR ACRYLIC LATEX
EXTRA WHITE, SW7006
P104
TRANSCERAMICA
1159 W BRYN MAWR
ITASCA IL 60143
PORCELAIN TILE PT109
NOREEN SCHERTLER
(312) 342-4689
MANDATORY INSTALLATION PER MANUFACTURER'S
SPECIFICATIONS.
TRANSCERAMICA
1159 W BRYN MAWR
ITASCA IL 60143
LARGE FORMAT PORCELAIN TILE
A.) 24"x24"x10mm #PFP2960
B.) 24"x6"x10mm #PFP2965
NEW GROUND; ANTHRACITE GROUND, (HONED FINISH)
GROUT: 1/16" THK., MAPEI #47 CHARCOAL (NO SUBSTITUTIONS)
PAINT
P114 PAINT (EGG SHELL)SHERWIN WILLIAMS
(800) 474-3794
SW7066, GRAY MATTERS
WILSONART(800) 433-3222
PLASTIC LAMINATE PL105 PLASTIC LAMINATE 7964K-12 SKYLINE WALNUT
DOORS (ALL SIDES INCLUDING BOTH FACES, LATCH SIDE,
HINGE SIDE, & TOP)
ROD SEABOLT
CDC DISTRIBUTORS
(513) 560 - 1040
FINISH - P104BASE
WALLCOVERING
WC105
WALLCOVERING
6" H x 3/4"T PAINTED WOOD BASE
W/ 3/8" TOP CHAMFER
TR
IM
CASING
CASING
T101 HARDWOOD CASING - PAINTED
T102 HARDWOOD CASING - PAINTED
3/4" x 3/4" HARDWOOD SQUARE FINISH - P104 (TYP. WHERE PT105 MEETS MILLWORK)
FINISH - P104 (TYP. AT O.D. ENTRY)6 3/8" W x 3/4"T PAINTED HARDWOOD CASING
CEILINGS AC-4 ARMSTRONG
(800) 442-4212;
OPTION #1
CLASS "A", REFERENCE "LUXOTTICA" AS ACCOUNT NAME2' x 2' LAY-IN; 15/16" GRID
1774 DUNE TEGULAR, 2'x2'x5/8" ANGLED TEGULAR PRELUDE
15/16" EXPOSED TEE GRID SYSTEM
WOLF GORDON INC.
HEIDI
SCHWARZINGER
REEF RFF 2557 VINYL WALLCOVERING WITH
OSNABURG BACKING - COLOR: ANCHOR
800 347 0550 X864; MOBILE 330 618 1296
WALLCOVERING
WC106
WALLCOVERING
SOURCE ONE
CONTRACT
MIKE THOMPSON,
614-551-7928
TEXTURA STONE, COLOR: BLACK
DIMENSIONS: 12”X24”, 1.5 MM. THK.
LOCATION: REFERENCE ARCHITECTURE DRAWINGS FOR LOCATIONS & SEAMING.
NOTES: PRODUCT IS GLUED TO WALL WITH STANDARD POLYURETHANE ADHESIVE.
INSTALL TILES HORIZONTALLY.
PAINT
P117 PAINT (SATIN) SHERWIN WILLIAMS(800) 474-3794
SW7068 GRIZZLE GRAY
DWB101MILLWORK WALL BASE
BASE
JOHNSONITE
TANDUS
JOHNSONITE
ROD SEABOLT
CDC DISTRIBUTORS
(513) 560 - 1040
MODEL/COLOR:
MANDALAY, MW-50-H6, 50 WHITE
FOR USE ON ROUND COLUMNS ONLY
C63CARPET TILE
CARPET TILE 24"x24", ULTRA NYLON 6,6
J&J INVISION
JEFF TAYLOR (P):
(800) 241-4586
STACKED MODULAR,
1404 STIMULATE 24x24 TILE
MONOLITHIC INSTALLATION, INSTALL MUST INCLUDE MFG.
RECOMMENDED INSTALL METHOD, FLOOR PREP & ADHESIVE
WB102 WOOD WALL BASE FINISH - P104BASE
4" H x 3/4"T PAINTED WOOD BASE
W/ 3/8" TOP CHAMFER
ACCENT WALL PAINT - OD AREA
MDF FILLERS AT EYE EXAM SIGN
FINISH SCHEDULE5
5-LCM17-A103-REV01
TRANSITION STRIP TS-14
TRANSITION STRIP (HIGH CARPET TO LOW
CARPET))
SCHLUTER
WWW.SCHLUTER.COM
1-800-472-4588
RENO-TK - ALUMINUM G.C. TO SIZE PER SITE CONDITION.
WC105W
8
11
P101 BEHIND PERIMETER
WALL FIXTURES
7
3
6
CLG. HT.=
PRETEST
102
10'-0"
CLG. HT.=
CONTACT LENS /
OPTICAL STATION
104
10'-0"
CLG. HT.=
REFRACTION
ROOM
101
10'-0"
CLG. HT.=
RETAIL SALES AREA
100
10'-6 1/2"
CLG. HT.=
OD RECEPTION
/ WAITING
103
8'-0"
FULL TILE /
LAYOUT POINT
TRUE NORTH PLAN NORTH
TS-10
10/A
500
TS-4
9/A
500
TS-4
9/A500
FULL
TILE
A
12
P114W
MACY'S RETAIL AREA
MACY'S RETAIL AREA
MACY'S RETAIL AREA
EXTERIOR
VESTIBU
LE
8
FULL TILE /
LAYOUT POINT
7
7
7
P101W
WB102B
PT108F
TS-10
10/A500
EXISTING COLUMN ENCLOSURE
WITH FULL HEIGHT MIRROR (4)
SIDES TO REMAIN. G.C. TO
INSTALL NEW WB102 BASE.
MACY'S FINISH
5
SIM.
(TYP. OPP.)
MACY'S FINISH
P114W
CHAIR RAIL (TYPICAL) -SEE
ELEVATIONS AND DETAIL
2/A500
CHAIR RAIL (TYPICAL) -SEE
ELEVATIONS AND DETAIL
2/A500
NOTE: VERIFY WITH NEXTORE
CONST. MGR. IF CHAIR RAIL IS TO
BE INSTALLED
A500
7
A500
8
FINISH PLAN
A103
1
5/17/2017 OWNERS COMMENTS
Seal
ByDateMark
Revisions:
a
ap
p
4000 Luxottica Place, Mason, OH 45040
6 Creamery Brook, East Granby, CT 06026
+1 (513) 765-6000
+1 (516) 393-2484
SheetDate
Drawn By
Checked By
Title
ISSUED FOR:
Nextore project
Number
Client Review
DOB Permit
DOB Permit - Re-Submit
Bid
Construction
LL Approval
Brand Design Type:
Construction for:
Nextore Store Design Revision No.:
DESIGN & CONSTRUCTION
MANAGEMENT:
74149
DESIGN REV 01
MODULAR
11/9/2017
STAFF
STAFF
4000 Luxo
ttica Place M
aso
n, O
hio
45040
A Sub
sid
iary o
f the Luxo
ttica G
ro
up
Architect / Engineer Job No.:
LCM 012
Architect of Record
2
11/10/2017 OWNERS COMMENTS
RETAIL SALES AREA : 100
SCALE: 1/4"=1'-0"
1
RETAIL SALES AREA : 100
SCALE: 1/4"=1'-0"
1A
RETAIL SALES AREA : 100
SCALE: 1/4"=1'-0"
2
PRETEST ROOM: 102
SCALE: 1/4"=1'-0"
9
PRETEST ROOM: 102
SCALE: 1/4"=1'-0"
10
OD RECEPTION / WAITING: 103
SCALE: 1/4"=1'-0"
7
PRETEST ROOM: 102
SCALE: 1/4"=1'-0"
8
REFRACTION ROOM
SCALE: 1/4"=1'-0"
11
REFRACTION ROOM
SCALE: 1/4"=1'-0"
12
REFRACTION ROOM
SCALE: 1/4"=1'-0"
13
REFRACTION ROOM
SCALE: 1/4"=1'-0"
14
0400-00
0440-00
0420-00
0440-00
0430-00 0451-00 0430-00
0835-00
0420-00
0440-00 0440-00
CASED OPENING
T102T
OPEN
7'-0"
4'-1
1
2
"
R.O. HOLD
GYP. BRD.
5'-0"
(WALL BEHIND
FIXTURES)
P101W
11
A500
WC105W
G.C. TO PROVIDE AND INSTALL 1X6 FIRE-RATED WOOD BLOCKING
IN WALL BEHIND GYP. BD. BETWEEN EACH STUD FOR WALL
FIXTURE MOUNTING. (TYPICAL WHERE WALL FIXTURES ARE
SHOWN)
WC105W
INSTALL WALLCOVERING 6"
BEHIND FIXTURES AS SHOWN
(TYP.)
EQ
.EQ
.
4"
12
A500
ILLUMINATED LENSCRAFTERS SIGN
BY SIGN CONTRACTOR. ELECTRICAL
CONTACTOR TO PROVIDE POWER
SEE ELECTRICAL DRAWINGS
WC105W
8'-0"
EQ.EQ.
1
A500
6" (TYP.)
6"
(TYP.)
2'-10
1
4
"
0400-00
8'-7
1
2
"
EXISTING
MACY'S FINISH
EXISTING
MACY'S FINISH
OPEN
WC105W
WB102B
WB102B
(DOOR PL105)
(FRAME P104)
WB102B
1'-6"
2'-10"
3'-0"
P101W
10'-0"
B.O. CEILING
10'-0" A.F.F.
C
L
C
L
4'-2
1
2
"
ELEC. OUTLET
4'-9"
EQUIPMENT
P101W
OUTLINE OF
RECESSED
OUTLET BOX. RE:
ELEC DRAWINGS
C
L
C
L
6'-0"
ELEC
TR
IC
AL O
UTLET
6'-6"
EQ
UIPM
EN
T
WB102B
2'-10"
1'-6"
3'-0"
WB102B
P114W
34"
T.O
. SIN
K
27" M
IN
1'-6"
15"
2'-10"
1'-6"
3'-0"
P101W
WB102B
10'-0"
B.O. CEILING
10'-0" A.F.F.
WB102B
P101W
WB102B
GC TO PROVIDE AND INSTALL CABINET HANDLE BUMPERS
AT ALL LOCATIONS WHERE HANDLES CAN MEET WALL IN
OPEN POSITION. SEE DETAIL 4 ON SHEET A500.
OPEN TO
BEYOND
WB102B
P101W P114W
WB102B
LCI-GH30
5'-0"
℄
P101W
2'-9
1 2
"3'-0
1 2
"
CG100W
CONTACT LENS : 104 / OPTICAL STATION : 104
SCALE: 1/4"=1'-0"
3
CONTACT LENS : 103 / OPTICAL STATION : 104
SCALE: 1/4"=1'-0"
4
CONTACT LENS : 103 / OPTICAL STATION : 104
SCALE: 1/4"=1'-0"
5
CONTACT LENS : 103 / OPTICAL STATION : 104
SCALE: 1/4"=1'-0"
6
NEW ENTRY DOOR
5'-0"
LCI-GH30LCI-GH30
8" 1'-0"
P101W P101W
P101W P114W
WB102B
WB102B
WB102BWB102B
4'-4"
SNAP FRAME SNAP FRAME
FIRE EXTINGUISHER
(DOOR PL105)
(FRAME P104)
LCI-GR32-EX1
9"
1'-0"
8'-0"
B.O. SOFFIT
8'-0" A.F.F.
10'-0"
B.O. CEILING
10'-0" A.F.F.
P101W P101W
WB102B
P114W
8'-0"
B.O. SOFFIT
8'-0" A.F.F.
10'-0"
B.O. CEILING
10'-0" A.F.F.
SE-GH24
LCI-GH16
OD ENTRY DOOR
SCALE: 1/4"=1'-0"
15
WB102B
5"
6
A500
SIM.
5
A500
LCM-GR-1
SE-GR15 or 15.1
NEW OD ENTRY
DOOR
NEW STAINLESS STEEL CORNER
GUARD (FULL PERIMETER OF
NEW OPENING
EXISTING MACY'S
FINISH TO
REMAIN
EXISTING
SECURITY
GRILLE
G.C. TO INSTALL FINISHES THIS AREA TO
MATCH MACY'S.. COORD. SCOPE OF
WORK WITH MACY'S REP.
2'-10"
5'-0"
CHAIR RAIL (TYP.) -SEE
ELEVATIONS AND DETAIL 2/A500.
NOTE: VERIFY WITH NEXTORE
CONST. MGR. IF CHAIR RAIL IS TO
BE INSTALLED
2'-10"
CHAIR RAIL (TYP.)
-SEE ELEVATIONS
AND DETAIL 2/A500
2'-10"
5'-6"
4'-10"
0820-00
XB-DFQ55
LCM-MW-CS.2
0821-00
1843-00
1840-00 1840-00 1840-00 1840-00 1840-00
1861-00
ALIGN
1863-00 1863-00 1863-00
6'-0"
V.I.F.
2'-6"
24" x 24" x 1/4" PLEXI SHIELD. COORDINATE DIMENSION
FROM BACK WALL IN FIELD. PLEXI TO PROTECT WALL
FROM SWING ARM. FASTEN TO STUDS OR TOGGLE BOLT
(8) SCREWS. ADDITIONAL PLEXI PIECE MAY BE REQUIRED
DUE TO SITE CONDITIONS. G.C. TO VERIFY WITH DR.
SCREWS FOR PLEXI SHIELD
GRAINGER
WASHER #8
ITEM # 2DE99
MFR. MODEL # 908018-PG
COUNTERSUNK WASHER,
NICKEL FINISH, FITS BOLT
SIZE #8, INSIDE DIA. 0.210
IN., OUTSIDE DIA.
17
32
IN.
FOR FINISHED
APPEARANCE. FOR USE
WITH 82 DEGREE FLAT
AND OVAL HEAD
COUNTERSUNK SCREWS.
3'-5"
RECESSED
ELECTRICAL
PANEL
PAINT P114
4'-9"
SE-GH-CHART
2'-6"
0821-00
0820-00 XB-DFQ55
LCM-MW-CS.2
0835-00
0821-00
LCM-MW-CS.2
0820-00 XB-DFQ55
PREMIER LMVS
LOW PROFILE
MOUNTING BRACKET
(TYP. OF 4)
PROVIDE IN WALL (2)
3
4
"
CONDUIT FROM
IN-WALL BOX TO 6" ABOVE
CEILING
IN-WALL:
ARLTVBU505BL -
ARLINGTON™ TVBU505BL
TWO-GANG RECESSED
ELECTRICAL BOX (BLACK),
OR EQUAL BLACK IN
COLOR)
C
L
5'-7 3/4" C
.L.
4'-0" x 6'-8" F.R
. PLY.
WO
OD
BLO
CKIN
G.
PA
IN
T TO
M
ATC
H
WA
LL BEH
IN
D
5'-3"
9"
SEE SHEET A100
FOR C.L. DIM
2 X DUPLEX (BLACK)
EXTENDED FROM
TOP BOX
INDICATES 3/4" F.R.T. IN-WALL
WOOD BLOCKING BETWEEN
STUDS
6'-5"
CHAIR RAIL (TYP.) -SEE ELEVATIONS AND DETAIL
2/A500.VERIFY WITH NEXTORE CONST. MGR. IF CHAIR
RAIL IS TO BE INSTALLED
10"
INTERIOR
ELEVATIONS
A200
1
5/17/2017 OWNERS COMMENTS
Seal
ByDateMark
Revisions:
a
ap
p
4000 Luxottica Place, Mason, OH 45040
6 Creamery Brook, East Granby, CT 06026
+1 (513) 765-6000
+1 (516) 393-2484
SheetDate
Drawn By
Checked By
Title
ISSUED FOR:
Nextore project
Number
Client Review
DOB Permit
DOB Permit - Re-Submit
Bid
Construction
LL Approval
Brand Design Type:
Construction for:
Nextore Store Design Revision No.:
DESIGN & CONSTRUCTION
MANAGEMENT:
74149
DESIGN REV 01
MODULAR
11/9/2017
STAFF
STAFF
4000 Luxo
ttica Place M
aso
n, O
hio
45040
A Sub
sid
iary o
f the Luxo
ttica G
ro
up
Architect / Engineer Job No.:
LCM 012
Architect of Record
2
11/10/2017 OWNERS COMMENTS
W/ SOUND BATTS
3
SCALE: 3/4"=1'-0"
WALL SECTION
OD AREA
BASE PER FINISH PLAN
/SCHEDULE. REFER TO SHEET
A103
SUSPENDED ACOUSTICAL
CEILING REFER REFLECTED
CEILING PLAN FOR CEILING
HEIGHTS
6"
EXISTING 2ND FLOOR
CONCRETE AND METAL DECK
OVER BAR JOISTS
B.O. DECK
16'-10" A.F.F.
FIRE PROOFED STRUCTURE
G.C. TO REPLACE ANY FIRE PROOFING
DAMAGED BY NEW WORK.
A300
C
A
B
C
2
'-
0
"
LIGHT FIXTURE
SCREW
METAL "T" BAR
4
'-
0
"
TO FIXTURE (OPPOSITE CORNERS), EXTENDING TO STRUCTURE ABOVE.
OF FIXTURE AT EACH CORNER. AND 12 GAGE SAFETY WIRES ATTACHED
12 GAGE WIRES ATTACHED TO MAIN OR CROSS TEES WITHIN 3"
INSTALL ONE SCREW AT OPPOSITE CORNERS OF FIXTURE TO MAIN
OR CROSS TEES.
8
"
C
SCREW
WIRES
SAFETY
12 GAGE HANGER WIRES AT 4'-0" O.C. EACH WAY
12 GAGE PERIMETER WIRES INSTALLED WITHIN 8" OF WALL
AT EACH MAIN AND CROSS TEE TO WALL JUNCTURE
MAIN SUPPORTS:
PERIMETER WIRES:
LIGHT FIXTURE SUPPORT:
4
'-
0
"
4
'-
0
"
B
8
"
A
CEILING TILE
(TYP.)
A
SCALE: 1/2"=1'-0"
SUSPENDED CEILING DETAIL
HILTI X-ZF # 32 P8/36M (0.145" SHANK DIA)
FASTENERS @ 16" O.C. (OR EQUAL)
CONCRETE SLAB
METAL STUDS SECTION DETAIL
METAL TRACK PER SECTION DETAIL
ACOUSTCAL CEILING ACOUSTCAL CEILING
3 5/8" X 20 GA DIAGONAL
BRACING @ 48" O.C.
ALTERNATING TO THE
STRUCTURE
3 5/8" X 20 GA TRACK
3"X3"X3"X18 GA CLIP ANGLES TO
TOP TRACK AND DIAGONAL
BRACING W/(2) #10 SCREW
CONNECTIONS, EA. LEG. CLIP
ANGLES AT 48" O.C. MAX.
METAL STUDS SECTION DETAIL
C
SCALE: 3"=1'-0"
TRACK TO SLAB DETAIL
B
SCALE: 3"=1'-0"
TRACK TO BRACE DETAIL
4
SCALE: 3/4"=1'-0"
WALL SECTION
SUSPENDED ACOUSTICAL
CEILING REFER REFLECTED
CEILING PLAN FOR CEILING
HEIGHTS
EXISTING 2ND FLOOR
CONCRETE AND METAL DECK
OVER BAR JOISTS
3
5
8
" x 20GA METAL STUD
DIAGONAL BRACING TO
STRUCTURE ABOVE
3
5
8
" x 20GA METAL STUD
DIAGONAL BRACING
ALTERNATING TO STRUCTURE
ABOVE, 48" O.C. (TYPICAL)
6"
NOTES:
A.) WALLS SHALL BE PLUMB TO WITHIN
1/8" TOP & BOTTOM AT MILLWORK
LOCATIONS
B.) SEE ELEVATIONS FOR WALL FINISHES
BASE PER FINISH PLAN
/SCHEDULE. REFER TO SHEET
A103
OD AREA OD AREA
3 5/8" X 20GA TRACK
(2) #10 SCREWS TO EA. METAL
STUD
FIRE PROOFED STRUCTURE
G.C. TO REPLACE ANY FIRE PROOFING
DAMAGED BY NEW WORK.
A300
B
A300
C
5
SCALE: 3/4"=1'-0"
WALL SECTION
SUSPENDED ACOUSTICAL
CEILING REFER REFLECTED
CEILING PLAN FOR CEILING
HEIGHTS
EXISTING 2ND FLOOR
CONCRETE AND METAL DECK
OVER BAR JOISTS
3
5
8
" x 20GA METAL STUD
DIAGONAL BRACING TO
STRUCTURE ABOVE
3
5
8
" x 20GA METAL STUD
DIAGONAL BRACING
ALTERNATING TO STRUCTURE
ABOVE, 48" O.C. (TYPICAL)
6"
NOTES:
A.) WALLS SHALL BE PLUMB TO WITHIN
1/8" TOP & BOTTOM AT MILLWORK
LOCATIONS
B.) SEE ELEVATIONS FOR WALL FINISHES
BASE PER FINISH PLAN
/SCHEDULE. REFER TO SHEET
A103
VOID SPACE OD AREA
3 5/8" X 20GA TRACK
(2) #10 SCREWS TO EA. METAL
STUD
FIRE PROOFED STRUCTURE
G.C. TO REPLACE ANY FIRE PROOFING
DAMAGED BY NEW WORK.
A300
B
A300
C
NOTE:
ADJUST SIZE OF FRAMING AS
REQUIRED. REFERENCE PLAN FOR
ADDITIONAL INFORMATION.
1
SCALE: 3/4"=1'-0"
WALL SECTION
TYPICAL INTERIOR PARTITION
BASE PER FINISH PLAN
/SCHEDULE. REFER TO SHEET
A103
EXISTING SUSPENDED
ACOUSTICAL CEILING REFER
REFLECTED CEILING PLAN FOR
CEILING HEIGHTS
EXISTING 2ND FLOOR
CONCRETE AND METAL DECK
OVER BAR JOISTS
B.O. DECK
17'-0" A.F.F.
RETAIL AREAMACY'S STOCK
RM
5
8
" GYP. BD. VENEER OVER
EXISTING WALL . LEVEL "4"
FINISH.
EXISTING IN WALL RECESSED
STANDARD TO REMAIN.
EXISTING FIRE PROOFED
BUILDING STEEL WHERE IT
OCCURS
2
SCALE: 3/4"=1'-0"
WALL SECTION
BASE PER FINISH PLAN
/SCHEDULE. REFER TO SHEET
A103
NOTES:
A.) WALLS SHALL BE PLUMB TO WITHIN
1/8" TOP & BOTTOM AT MILLWORK
LOCATIONS
B.) SEE ELEVATIONS FOR WALL FINISHES
SUSPENDED ACOUSTICAL
CEILING REFER REFLECTED
CEILING PLAN FOR CEILING
HEIGHTS
3
5
8
" x 20GA METAL STUD
DIAGONAL BRACING
ALTERNATING TO STRUCTURE
ABOVE, 48" O.C. (TYPICAL)
EXISTING 2ND FLOOR
CONCRETE AND METAL DECK
OVER STRUCTURAL STEEL
3
5
8
" x 20GA METAL STUD
DIAGONAL BRACING TO
STRUCTURE ABOVE
RETAIL AREAOD
FIRE PROOFED STRUCTURE
G.C. TO REPLACE ANY FIRE PROOFING
DAMAGED BY NEW WORK.
A500
13
A300
C
B.O. DECK
FIELD VERIFY
EXISTING CEILING. REFER
REFLECTED CEILING PLAN FOR
CEILING HEIGHTS
SIM.
6
SCALE: 3/4"=1'-0"
WALL SECTION
BASE PER FINISH PLAN
/SCHEDULE. REFER TO SHEET
A103
EXISTING SUSPENDED
ACOUSTICAL CEILING REFER
REFLECTED CEILING PLAN FOR
CEILING HEIGHTS
EXISTING 2ND FLOOR
CONCRETE AND METAL DECK
OVER BAR JOISTS
B.O. DECK
17'-0" A.F.F.
RETAIL AREAMACY'S STOCK
RM
5
8
" GYP. BD. VENEER OVER
EXISTING WALL . LEVEL "4"
FINISH.
EXISTING IN WALL RECESSED
STANDARD TO REMAIN.
EXISTING FIRE PROOFED
BUILDING STEEL WHERE IT
OCCURS
EXISTING RECESSED STANDARDS ARE TO BE
COVERED WITH NEW DRYWALL IN SUCH A
MANNER AS TO PRESENT A FLAT AND
SMOOTH SUBSTRATE. NO EVIDENCE OF
THESE EXISTING STANDARDS SHALL BE
ALLOWED TO TELEGRAPH THRU THE NEW
CONSTRUCTION IN SUCH A MANNER AS TO
CAUSE ANYTHING LESS THAN A SMOOTH
AND FLAT FINISHED SURFACE.
SECTIONS
A300
N
O
T
U
S
E
D
N
O
T
U
S
E
D
N
O
T
U
S
E
D
1
5/17/2017 OWNERS COMMENTS
Seal
ByDateMark
Revisions:
a
ap
p
4000 Luxottica Place, Mason, OH 45040
6 Creamery Brook, East Granby, CT 06026
+1 (513) 765-6000
+1 (516) 393-2484
SheetDate
Drawn By
Checked By
Title
ISSUED FOR:
Nextore project
Number
Client Review
DOB Permit
DOB Permit - Re-Submit
Bid
Construction
LL Approval
Brand Design Type:
Construction for:
Nextore Store Design Revision No.:
DESIGN & CONSTRUCTION
MANAGEMENT:
74149
DESIGN REV 01
MODULAR
11/9/2017
STAFF
STAFF
4000 Luxo
ttica Place M
aso
n, O
hio
45040
A Sub
sid
iary o
f the Luxo
ttica G
ro
up
Architect / Engineer Job No.:
LCM 012
Architect of Record
2
11/10/2017 OWNERS COMMENTS
SECTION
SCALE: 1 1/2" = 1'-0"
1
EXIST. ACT CLG
B.O. FINISHED CASED
OPENING:
9'-3 7/8" WHEN DOORWAY
ABUTTS TILED WALL,
9'-2 7/8" WHEN NOT
ABUTTING TILED WALL.
SEE CONSTRUCTION PLAN
A101 DOOR TYPES FOR
SPECIFIC HEIGHT
T102T
CASED OPENING TRIM
PAINTED "P104"
ACT CLG
PARTITION PER CONSTRUCTION PLAN
B.O. O.D. CEILING
10'-0"
3 4
"
VA
RIES
1-LCM17-A500-REV00
B.O. R.O. / T.O. TRIM = 9'-3 5/8" A.F.F.
B.O. SALES AREA CEILING =
10'-6 1/2" A.F.F.
A500
13
SIM.
SECTION THRU - LENS CRAFTERS SIGN
SCALE: 1 1/2" = 1'-0"
11
11-LCM17-A500-REV00
ACT CLG
PARTITION PER
CONSTRUCTION PLAN
OUTLINE OF MILLWORK
FIXTURE BELOW.
G.C. TO PROVIDE AND
INSTALL 1 X 6 FIRE
RETARDANT BLOCKING IN
WALL AT 6'-5" A.F.F. BEHIND
ALL PERIMETER WALL
FIXTURES.
B.O. SALES AREA CEILING =
10'-6 1/2" A.F.F.
WALLCOVERING. INSTALL 6"
BELOW TOP OF CABINET AS
SHOWN
WC105W
EXIST. ACT CLG.
4 7/8"
6
3 8
"
CASED OPENING - DETAIL
SCALE: 6" = 1'-0"
5
6 3/8"W x3/4"T TRIM - PAINTED
P104 - GLUED & SCREWED. COUNTER
SINK SCREWS, FILL AND PREPARE FOR
PAINT. PROVIDED AND INSTALLED BY
G.C.
SEE ELEVATION SHEETS A200 & A201
T102W
WB101B
T102T
NON-COMBUSTABLE
BLOCKING
LINE OF SIGN
ABOVE
WB102B
CORNERBEAD
5-LCM17-A500-REV00
OD AREA
RETAIL AREA
CHAIR RAIL:
JOHNSONITE; 4”
RAMPART CHR-50-C
(WHITE COLOR)
CHAIR RAIL DETAIL
SCALE: 6"=1'-0"
2
TOP @ 2'-10" A.F.F.
P104W
2-LCM17-A500-REV00
CHAIR RAIL -RETURN
MITER TO WALL AS
SHOWN (TYPICAL)
WALL BASE DETAIL
SCALE: 6"=1'-0"
3
4" (W
B102)
6" (W
B101)
6" WALL BASE
FINISH: P104
FINISH FLOOR,
SEE SHEET A103
3 8
"
PROVIDED AND
INSTALLED BY G.C.
3-LCM17-A500-REV00
CABINET DOOR HANDLE - WALL BUMPER
SCALE: 6" = 1'-0"
4
CABINET HANDLE WALL BUMPER
PROVIDED AND INSTALLED BY GC
SEE SHEET A100 ARCH. FINISH SCHEDULE
FOR MODEL INFORMATION.
PROVIDE WHERE ANY CABINET DOOR HANDLE
CAN MEET WALL SURFACE IN OPEN POSITION.
4-LCM17-A500-REV00
WALL COVERING INSTALL
SCALE: 3" = 1'-0"
6
LINE OF MILLWORK EDGE.
SEE ELEVATION SHEET A200 FOR DIMENSIONS
AND EXTENTS OF MILLWORK
5/8" GYP. W FINISH BEHIND
MILLWORK
5 8
"
INSTALL WALL COVERING (WC105).
WALL COVERING EXTENDS TO 6"
BEHIND MILLWORK.
6"
WC105W
(WD201) WOOD FINISH.
PROVIDED BY TENANT. CUSTOM
FIT PROVIDED AND INSTALLED BY
MILLWORKER.
6"
5 8
"
MILLWORK
SURROUND ABOVE
4"
3 4
"
QU
IR
K
SEE ELEVATION SHEET A200
FOR DIMENSIONS AND
EXTENTS OF WALL COVERING
6-LCM17-A500-REV00
LINE OF
BASE BELOW
EXISTING CONSTRUCTION
1"
EXISTING CROWN ABOVE
WALL FINISH TRANSITION
SCALE: 6" = 1'-0"
8
SECTION THRU - LENS CRAFTERS SIGN
SCALE: 1 1/2" = 1'-0"
12
MILLWORK PROVIDED BY TENANT.
CUSTOM FIT PROVIDED AND INSTALLED
BY MILLWORKER. SEE ELEVATION FOR
LOCATION
4"
EXIST. ACT CLG.
10'-6 1/2"
PARTITION PER
CONSTRUCTION PLAN
OUTLINE OF MILLWORK
FIXTURE BEYOND
J-BOX ABOVE CEILING @ 6"
ABOVE CENTERLINE OF SIGN, BY
G.C. WITH FLEX WHIP ROUTED IN
WALL INTO SIGN CABINET. SEE
ELECTRICAL DRAWINGS
ILLUMINATED "LENS CRAFTERS"
SIGN CABINET BY SIGN
CONTRACTOR. SEE ELEVATION
FOR SPECIFIC HEIGHT LOCATION
G.C. TO PROVIDE MTL.
STRAPPING IN WALL FOR SIGN
MOUNTING.
5
1 4
"
5
1 4
"
ACT CLG
1/2" F.R. PLYWOOD SUBFLOOR-VERIFY
HEIGHT REQ'D IN FIELD
PORC. TILE ON THIN SET MORTAR BED
GLUE DOWN CARPET PER
PLANS AND SCHEDULES
LINE OF EXTG. CONCRETE SLAB
FLOOR TRANSITION DETAIL
SCALE: 6" = 1'-0"
9
TRANSITION STRIP (TS-4) PER
PLANS AND SCHEDULES INSTALL
CARPET ON SUBFLOOR TO
ALIGN CARPET PILE HEIGHT WITH
ADJACENT FINISHED TILE
FLOORING
TS-4 CARPET TO PORCELAIN 9-LCM17-A500-REV00
TS-10 TRANSITION
STRIP PER PLANS AND
SCHEDULES
THIN SET MORTAR BED
LINE OF EXISTING CONCRETE
SLAB
NOTE: PREPARE EXISTING
CONCRETE SLAB AS REQUIRED
TO PROVIDE LEVEL
TRANSITION.
ALIGN
FLOOR TRANSITION DETAIL
SCALE: 6" = 1'-0"
10
10-LCM17-A500-REV00
NEW WALL TO EXIST. DROP CEILING - SIMILAR
SCALE: 6"=1'-0"
13
T.O
. J BEA
D @
3/8"
BELO
W EX
IST. G
RID
DIAGONAL BRACING AS SPECIFIED
EXIST. CEIL. GRID TO
CONT. ABOVE NEW WALL
CUT CEIL. TILE @ TOP
PLATE TO ENABLE TILE
TO RECESS.
NEW WALL
EXIST. CEIL. GRID
MUD ON J BEAD
SECTION PLAN
ADA ACCESSIBLE CHECK-OUT COUNTER
SCALE: 3/4" = 1'-0"
14
12-LCM17-A500-REV00
2'-9
1 2
"
4'-0"
2'-6"
3'-0" CLEAR
2'-5
1
2
"
WALL FINISH TRANSITION
SCALE: 6" = 1'-0"
7
4"
4"W x3/4"T TRIM - PAINTED P104.
GLUED & SCREWED. COUNTER SINK
SCREWS, FILL AND PREPARE FOR PAINT.
PROVIDED AND INSTALLED BY G.C.
LINE OF
BASE BELOW
EXISTING CONSTRUCTION
DETAILS
A500
1
5/17/2017 OWNERS COMMENTS
Seal
ByDateMark
Revisions:
a
ap
p
4000 Luxottica Place, Mason, OH 45040
6 Creamery Brook, East Granby, CT 06026
+1 (513) 765-6000
+1 (516) 393-2484
SheetDate
Drawn By
Checked By
Title
ISSUED FOR:
Nextore project
Number
Client Review
DOB Permit
DOB Permit - Re-Submit
Bid
Construction
LL Approval
Brand Design Type:
Construction for:
Nextore Store Design Revision No.:
DESIGN & CONSTRUCTION
MANAGEMENT:
74149
DESIGN REV 01
MODULAR
11/9/2017
STAFF
STAFF
4000 Luxo
ttica Place M
aso
n, O
hio
45040
A Sub
sid
iary o
f the Luxo
ttica G
ro
up
Architect / Engineer Job No.:
LCM 012
Architect of Record
2
11/10/2017 OWNERS COMMENTS
STORE #8871
NORTH EAST MALL
1101 MELBOURNE RD. SUITE 3000
HURST, TEXAS 76053
1
5/17/2017 OWNERS COMMENTS
Seal
ByDateMark
Revisions:
a
ap
p
4000 Luxottica Place, Mason, OH 45040
6 Creamery Brook, East Granby, CT 06026
+1 (513) 765-6000
+1 (516) 393-2484
SheetDate
Drawn By
Checked By
Title
ISSUED FOR:
Nextore project
Number
Client Review
DOB Permit
DOB Permit - Re-Submit
Bid
Construction
LL Approval
Brand Design Type:
Construction for:
Nextore Store Design Revision No.:
DESIGN & CONSTRUCTION
MANAGEMENT:
74149
DESIGN REV 01
MODULAR
11/9/2017
STAFF
SRH
4000 Luxo
ttica Place M
aso
n, O
hio
45040
A Sub
sid
iary o
f the Luxo
ttica G
ro
up
Architect / Engineer Job No.:
LCM 012
Engineer of Record
2
11/10/2017 OWNERS COMMENTS
OVERALL FLOOR
PLAN - MEP
SERVICES
MPE100
EXISTING FLOOR PLAN - SECOND FLOOR
SCALE: 1"=40'-0"
1
PLAN NORTH
SHEETMPE100H200P200E100E200E300
DESCRIPTIONMECHANICAL, PLUMBING AND ELECTRICAL OVERALL BUILDING PLANS; SPECIFICATIONSHVAC DEMOLITION AND NEW PLANSPLUMBING PLANS AND RISERSELECTRICAL DETAILS, SYMBOLS AND DEMOLITION PLANELECTRICAL LIGHTING, POWER AND LOW VOLTAGE PLANS ELECTRICAL RISER DIAGRAM AND SCHEDULES
MECHANICAL, PLUMBING, & ELECTRICAL DRAWING INDEX2
2-LCM-MPE100-REV 0.0
KEY NOTES - MECHANICAL/PLUMBING/ELECTRICAL OVERALL PLAN
1. LOCATION OF SANITARY AND VENT. FIELD VERIFY LOCATION OF PIPING AND CONNECT TO NEW LC MACY'S. CONTRACTOR ISTO SUGGEST ALTERNATE LOCATIONS IF THEY ARE DISCOVERED DURING BIDDING/CONSTRUCTION.
2. UTILIZE PANEL "L7A" FOR THE 60A FEED TO NEW LOAD CENTER "A" IN THE LENSCRAFTER'S SPACE. VERIFY CURRENT LOAD ONPANEL AND REPORT TO ENGINEER TO CONFIRM PANEL CAPACITY. SEE RISER DIAGRAM FOR PANEL IDENTIFICATION.
3. LOCATION OF EXISTING PHONE ROOM.
4. EXISTING WATER SUPPLY LOCATION. VERIFY IN FIELD PRIOR TO START OF WORK.
5. LOCATION OF EXISTING POS ROOM - ON 3RD LEVEL - IDF3.
XX
LOCATION OF PROPOSEDNEW LENS CRAFTERS PAD
LOCATION OF ELECTRICALROOM FOR SERVICE TOLENSCRAFTERS.
LOCATION OF WATER,SANITARY AND VENT
LOCATION OF PHONEROOM.
1
2
3
4
1
1-LCM-MPE100-REV 0.0
DIVISION 15000A - PLUMBING
PART 1 - GENERAL
A. GENERAL CONDITIONS, CODES & STANDARDS
1. ALL WORK SHOWN ON THE PLUMBING DOCUMENTS IS TO BE PROVIDED AND
INSTALLED BY THE PLUMBING CONTRACTOR, UNLESS NOTED OTHERWISE.
2. ALL WORK TO MEET APPLICABLE CODES AS LOCALLY ENFORCED. NO WORK ON
THE DRAWINGS IS TO BE INSTALLED WHERE IT CONFLICTS WITH LOCAL CODE
ENFORCEMENT. COORDINATE WITH THE LOCAL INSPECTOR PRIOR TO
INSTALLATION.
3. GENERAL CONTRACTOR SHALL PAY FOR AND OBTAIN ALL NECESSARY LICENSES,
PERMITS AND INSPECTIONS REQUIRED TO PROCEED WITH THE WORK. THIS SHALL
INCLUDE ALL REQUIRED COORDINATION WITH THE LOCAL UTILITY COMPANIES
AND THEIR ASSOCIATED FEES OR COSTS.
B. SCOPE OF WORK
1.ONLY MAJOR EQUIPMENT IS SHOWN ON THE DRAWINGS. THE PLUMBING
CONTRACTOR SHALL BID AND CONSTRUCT A COMPLETE AND OPERATIONAL
SYSTEM. MISCELLANEOUS EQUIPMENT REQUIRED TO COMPLETE THE WORK IS IN
THE PLUMBING CONTRACTOR'S SCOPE - ASSUME NO WORK OR EQUIPMENT IS
PROVIDED BY OTHERS UNLESS STATED AS SUCH.
2. DURING BIDDING:
2.1. VERIFY THE EXISTING CONDITIONS AND COMPENSATE FOR ANY VARIATIONS
IN THE SCOPE AS A RESULT.
2.3. WHERE THERE IS A CONFLICT THAT CANNOT BE RESOLVED BY THE GENERAL
CONTRACTOR, ADVISE ENGINEER PROMPTLY FOR A RESOLUTION. DO NOT
PROVIDE WORK WHEN THERE IS UNCERTAINTY ON WHAT WORK IS TO BE
PERFORMED.
3. AS PART OF THE BIDDING PROCESS, REPORT TO THE TENANT ANY ERRORS OR
UNCLEAR DIRECTIONS THAT YOU HAVE IDENTIFIED.
C. DOCUMENTS
1.SUBSTITUTIONS
1.1. THE MANUFACTURERS AND MODEL NUMBERS INDICATED IN THE CONTRACT
DOCUMENTS ARE FOR THE PURPOSE OF DESCRIPTION AND TO ESTABLISH A
BASE LEVEL OF QUALITY. THE GENERAL CONTRACTOR'S BID WILL CONTEMPLATE
THE USE OF THE EQUIPMENT AND MATERIALS EQUIVALENT TO THOSE
INDICATED.
2. MISCELLANEOUS ITEMS NECESSARY TO COMPLETE THE SYSTEMS CAN BE OF
ANY RECOGNIZED MANUFACTURE PROVIDED THESE ITEMS MEET MINIMUM
STANDARDS AS SET IN THESE SPECIFICATIONS.
D. CONSTRUCTION COORDINATION
1.DURING BIDDING YOU VISITED THE SITE. WORK WITH THE GENERAL CONTRACTOR
TO COORDINATE ANY CONFLICTS WITH EXISTING CONDITIONS. THIS WORK SHALL
BE PROVIDED AT NO ADDITIONAL COST TO THE TENANT.
2. GENERAL CONTRACTOR SHALL LOCATE, IDENTIFY AND PROTECT ANY
EXISTING SERVICES WHICH ARE REQUIRED TO BE MAINTAINED OPERATIONAL AND
SHALL EXERCISE EXTRA CAUTION IN THE PERFORMANCE OF ALL WORK TO AVOID
DISTURBING SUCH FACILITIES. ALL COSTS FOR REPAIR OF DAMAGES TO SUCH
SERVICES SHALL BE PAID BY THE GENERAL CONTRACTOR CAUSING THE DAMAGE.
PART 2 - MATERIALS
A. GENERAL
1.PROVIDE STOP VALVES AT EVERY FIXTURE ON BOTH HOT AND COLD WATER
SUPPLY LINES. VALVES, ESCUTCHEONS, FITTINGS, ETC. MUST BE CHROME PLATED.
WHERE EXPOSED, CHROME PLATED PIPE IS TO BE USED.
2. ALL ABOVE GROUND PIPING SHALL BE INSULATED WITH FIBERGLASS PIPING
INSULATION WITH AN ALL SERVICE JACKET AND SELF SEALING LAP (ASJ/SSL).
2.1 DOMESTIC HOT AND COLD WATER PIPING UP TO 3/4 INCH DIAMETER - 1/2
INCH THICK.
2.2 FITTINGS AND VALVES SHALL BE INSULATED WITH PRE-MOLDED FIBERGLASS
FITTINGS AND COVERED WITH A PRE-FORMED PVC FITTING COVER.
PART 3 - EXECUTION
A. GENERAL
1.THE ENTIRE PLUMBING INSTALLATION, MATERIALS, EQUIPMENT, ETC. SHALL
CONFORM TO THE REQUIREMENTS OF THE LOCALLY ENFORCED CODES AND
STANDARDS.
1.1. VERIFY FINAL ROUGH IN WITH ARCHITECT PRIOR TO WALL INSTALLATION.
2. PIPING IS TO BE INSTALLED CONCEALED - SURFACE MOUNTED PIPING IN
FINISHED AREAS IS NOT ACCEPTABLE.
3. ALL EXPOSED OR ACCESSIBLE P-TRAPS MUST BE PROVIDED WITH BOTTOM
CLEANOUT PLUGS.
4. INSULATE EXPOSED P-TRAPS, HOT AND COLD VALVES AND PIPING SERVING
HANDICAPPED LAVATORIES.
5. IF SPACE ABOVE CEILING IS INDICATED TO BE A RETURN AIR PLENUM.
CONSTRUCTION MATERIALS ABOVE CEILING SHALL BE NONCOMBUSTIBLE, OR
HAVE A MAXIMUM 25 FLAME SPREAD AND 50 SMOKE DEVELOPMENT FINISH
RATING. WIRING SHALL BE LABELED PLENUM RATED TYPE PER NFPA 70.
6. ALL CLEANOUTS ARE TO BE INSTALLED FLUSH WITH THE FINISHED FLOOR OR
WALL.
B. INSULATION
1.EXTEND INSULATION WITHOUT INTERRUPTION THROUGH WALLS, FLOORS,
HANGERS AND SIMILAR PENETRATIONS.
2. MAINTAIN ACCESS TO VALVES
DIVISION 15000B - MECHANICAL
I. GENERAL PROVISIONS
A. GENERAL CONDITIONS, CODES & STANDARDS
1.ALL WORK SHOWN ON THE MECHANICAL DOCUMENTS IS TO BE PROVIDED
AND INSTALLED BY THE PLUMBING CONTRACTOR, UNLESS NOTED
OTHERWISE.
2. ALL WORK TO MEET APPLICABLE CODES AS LOCALLY ENFORCED. NO
WORK ON THE DRAWINGS IS TO BE INSTALLED WHERE IT CONFLICTS WITH
LOCAL CODE ENFORCEMENT. COORDINATE WITH THE LOCAL INSPECTOR
PRIOR TO INSTALLATION.
3. GENERAL CONTRACTOR SHALL PAY FOR AND OBTAIN ALL NECESSARY
LICENSES, PERMITS AND INSPECTIONS REQUIRED TO PROCEED WITH THE
WORK. THIS SHALL INCLUDE ALL REQUIRED COORDINATION WITH THE
LOCAL UTILITY COMPANIES AND THEIR ASSOCIATED FEES OR COSTS.
B. SCOPE OF WORK
1.ONLY MAJOR EQUIPMENT IS SHOWN ON THE DRAWINGS. THE
MECHANICAL CONTRACTOR SHALL BID AND CONSTRUCT A COMPLETE AND
OPERATIONAL SYSTEM. MISCELLANEOUS EQUIPMENT REQUIRED TO
COMPLETE THE WORK IS IN THE MECHANICAL CONTRACTOR'S SCOPE -
ASSUME NO WORK OR EQUIPMENT IS PROVIDED BY OTHERS UNLESS
STATED AS SUCH.
2. DURING BIDDING:
2.1. VERIFY THE EXISTING CONDITIONS AND COMPENSATE FOR ANY
VARIATIONS IN THE SCOPE AS A RESULT.
2.3. WHERE THERE IS A CONFLICT THAT CANNOT BE RESOLVED BY THE
GENERAL CONTRACTOR, ADVISE ENGINEER PROMPTLY FOR A RESOLUTION.
DO NOT PROVIDE WORK WHEN THERE IS UNCERTAINTY ON WHAT WORK
IS TO BE PERFORMED.
3. AS PART OF THE BIDDING PROCESS, REPORT TO THE TENANT ANY
ERRORS OR UNCLEAR DIRECTIONS THAT YOU HAVE IDENTIFIED.
C. DOCUMENTS
1.SUBSTITUTIONS
1.1. THE MANUFACTURERS AND MODEL NUMBERS INDICATED IN THE
CONTRACT DOCUMENTS ARE FOR THE PURPOSE OF DESCRIPTION AND TO
ESTABLISH A BASE LEVEL OF QUALITY. THE GENERAL CONTRACTOR'S BID
WILL CONTEMPLATE THE USE OF THE EQUIPMENT AND MATERIALS
EQUIVALENT TO THOSE INDICATED.
2. MISCELLANEOUS ITEMS NECESSARY TO COMPLETE THE SYSTEMS CAN
BE OF ANY RECOGNIZED MANUFACTURE PROVIDED THESE ITEMS MEET
MINIMUM STANDARDS AS SET IN THESE SPECIFICATIONS.
D. CONSTRUCTION COORDINATION
1.DURING BIDDING YOU VISITED THE SITE. WORK WITH THE GENERAL
CONTRACTOR TO COORDINATE ANY CONFLICTS WITH EXISTING
CONDITIONS. THIS WORK SHALL BE PROVIDED AT NO ADDITIONAL COST
TO THE TENANT.
2. GENERAL CONTRACTOR SHALL LOCATE, IDENTIFY AND PROTECT ANY
EXISTING SERVICES WHICH ARE REQUIRED TO BE MAINTAINED
OPERATIONAL AND SHALL EXERCISE EXTRA CAUTION IN THE PERFORMANCE
OF ALL WORK TO AVOID DISTURBING SUCH FACILITIES. ALL COSTS FOR
REPAIR OF DAMAGES TO SUCH SERVICES SHALL BE PAID BY THE GENERAL
CONTRACTOR CAUSING THE DAMAGE.
II. INSULATION
A. GENERAL
1.EXTEND INSULATION WITHOUT INTERRUPTION THROUGH WALLS, FLOORS,
HANGERS AND SIMILAR PENETRATIONS.
2. MAINTAIN ACCESS TO BALANCING DAMPERS AND VALVES.
3. INSULATION SHALL BE BY OWENS-CORNING, KNAUF, OR MANVILLE.
4. ALL DUCTWORK AND PIPING SHALL BE INSULATED
VI. AIR DISTRIBUTION
A. AIR DISTRIBUTION
1.DUCTWORK (ROUND OR RECTANGULAR OR SPIRAL) SHALL BE OF
GALVANIZED STEEL CONSTRUCTION AND SHALL BE INSTALLED IN
ACCORDANCE WITH THE LATEST EDITION OF THE SMACNA MANUAL AND
SEALED.
2. CHANGES IN DUCT SIZES SHALL BE MADE BY UNIFORM TAPER SECTION
WITH A MAXIMUM INCLUDE ANGLE OF DIVERGENCE OF 15DEGREES.
3. FINAL CONNECTIONS TO DIFFUSERS MAY BE MADE WITH FLEXIBLE
DUCTWORK BUT IT'S USE IS LIMITED TO STRAIGHT HORIZONTAL OR
VERTICAL RUNS. ALL CHANGES OF DIRECTION IN A DUCT SYSTEM
(GALVANIZED OR FLEXIBLE) SHALL BE MADE WITH AN APPROPRIATE
GALVANIZED ELBOW. MAXIMUM LENGTH OF ANY FLEXIBLE DUCT IS 5'-0".
4. FLEXIBLE DUCTS TO DIFFUSERS: MAXIMUM LENGTH OF FLEXIBLE DUCT
TO DIFFUSER TO BE 5'-0".
VIII. TESTING AND BALANCING
A. SYSTEM TO BE TESTED AND BALANCED WITH A REPORT SHOWING
ACTUAL AIR FLOWS AT NEWLY INSTALLED DIFFUSERS. AIR FLOW TO BE
WITHIN 15% OF THE DESIGN VALUE SHOWN ON THE DRAWINGS. WHERE THIS
AIR QUANTITY CANNOT BE MET, ADJUST UPSTREAM DAMPERS UNTIL IT IS MET.
COORDINATE THIS WORK WITH MACY'S OPERATIONS.
DIVISION 16000 - ELECTRICAL
PART I - GENERAL
A. GENERAL CONDITIONS, CODES & STANDARDS
1.ALL WORK SHOWN ON THE ELECTRICAL DOCUMENTS IS
TO BE PROVIDED AND INSTALLED BY THE ELECTRICAL
CONTRACTOR, UNLESS NOTED OTHERWISE.
2. ALL WORK TO MEET APPLICABLE CODES AS LOCALLY
ENFORCED. NO WORK ON THE DRAWINGS IS TO BE
INSTALLED WHERE IT CONFLICTS WITH LOCAL CODE
ENFORCEMENT. COORDINATE WITH THE LOCAL
INSPECTOR PRIOR TO INSTALLATION.
3. ELECTRICAL CONTRACTOR SHALL PAY FOR AND
OBTAIN ALL NECESSARY LICENSES, PERMITS AND
INSPECTIONS REQUIRED TO PROCEED WITH THE WORK.
THIS SHALL INCLUDE ALL REQUIRED COORDINATION WITH
THE LOCAL UTILITY COMPANIES AND THEIR ASSOCIATED
FEES OR COSTS.
4. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL
LABOR, MATERIAL, EQUIPMENT AND TOOLS NECESSARY
TO COMPLETE THE ELECTRICAL WORK AS SHOWN ON THE
DRAWINGS OR SPECIFIED HEREIN.
5. TEMPORARY ELECTRICAL SERVICE, LIGHTING, AND
RELATED WIRING SHALL BE PROVIDED TO OSHA
REQUIREMENTS FOR THE USE OF ALL TRADES DURING
CONSTRUCTION.
B. SCOPE OF WORK
1.ONLY MAJOR EQUIPMENT IS SHOWN ON THE DRAWINGS.
THE ELECTRICAL CONTRACTOR SHALL BID AND
CONSTRUCT A COMPLETE AND OPERATIONAL SYSTEM.
MISCELLANEOUS EQUIPMENT REQUIRED TO COMPLETE
THE WORK IS IN THE ELECTRICAL CONTRACTOR'S SCOPE -
ASSUME NO WORK OR EQUIPMENT IS PROVIDED BY
OTHERS UNLESS STATED AS SUCH.
2. DURING BIDDING:
2.1. VERIFY THE EXISTING CONDITIONS AND COMPENSATE
FOR ANY VARIATIONS IN THE SCOPE AS A RESULT.
2.3. WHERE THERE IS A CONFLICT THAT CANNOT BE
RESOLVED BY THE GENERAL CONTRACTOR, ADVISE
ENGINEER PROMPTLY FOR A RESOLUTION. DO NOT
PROVIDE WORK WHEN THERE IS UNCERTAINTY ON
WHAT WORK IS TO BE PERFORMED.
3. AS PART OF THE BIDDING PROCESS, REPORT TO THE
TENANT ANY ERRORS OR UNCLEAR DIRECTIONS THAT
YOU HAVE IDENTIFIED.
C. DOCUMENTS
1.SUBSTITUTIONS
1.1. THE MANUFACTURERS AND MODEL NUMBERS
INDICATED IN THE CONTRACT DOCUMENTS ARE FOR
THE PURPOSE OF DESCRIPTION AND TO ESTABLISH A
BASE LEVEL OF QUALITY. THE GENERAL CONTRACTOR'S
BID WILL CONTEMPLATE THE USE OF THE EQUIPMENT
AND MATERIALS EQUIVALENT TO THOSE INDICATED.
2. MISCELLANEOUS ITEMS NECESSARY TO COMPLETE
THE SYSTEMS CAN BE OF ANY RECOGNIZED
MANUFACTURE PROVIDED THESE ITEMS MEET MINIMUM
STANDARDS AS SET IN THESE SPECIFICATIONS.
D. CONSTRUCTION COORDINATION
1.DURING BIDDING YOU VISITED THE SITE. WORK WITH THE
GENERAL CONTRACTOR TO COORDINATE ANY CONFLICTS
WITH EXISTING CONDITIONS. THIS WORK SHALL BE
PROVIDED AT NO ADDITIONAL COST TO THE TENANT.
2. GENERAL CONTRACTOR SHALL LOCATE, IDENTIFY
AND PROTECT ANY EXISTING SERVICES WHICH ARE
REQUIRED TO BE MAINTAINED OPERATIONAL AND SHALL
EXERCISE EXTRA CAUTION IN THE PERFORMANCE OF ALL
WORK TO AVOID DISTURBING SUCH FACILITIES. ALL
COSTS FOR REPAIR OF DAMAGES TO SUCH SERVICES
SHALL BE PAID BY THE GENERAL CONTRACTOR CAUSING
THE DAMAGE.
PART 2 - PRODUCTS
A. WIRING DEVICES
1.DUPLEX RECEPTACLES SHALL BE GROUNDING TYPE, NEMA
5-20R, RATED FOR 20 AMPS, 125 VOLTS, WITH PROVISIONS
FOR BACK AND SIDE WIRING.
1.1. SPECIFICATION GRADE DUPLEX RECEPTACLE SHALL BE
HUBBELL #5362 SERIES OR APPROVED EQUAL, HEAVY
DUTY, WHITE.
1.3. GROUND FAULT CIRCUIT INTERRUPTER (GFI) DUPLEX
RECEPTACLES SHALL BE PROVIDED WHERE INDICATED.
2. SWITCHES SHALL BE TOGGLE OPERATED, QUIET TYPE,
RATED FOR 20 AMPS, 120/277 VOLTS, WITH PROVISIONS
FOR BACK AND SIDE WIRING. THREE WAY AND FOUR WAY
SWITCHES SHALL BE PROVIDED WHERE INDICATED.
2.1. SINGLE POLE SWITCHES SHALL BE LEVITON #1221
SERIES OR APPROVED EQUAL, SILENT ACTUATING,
20-AMP, 120/277V, WHITE.
2.2. THREE POLE SWITCHES SHALL BE LEVITON #1223
SERIES OR APPROVED EQUAL, SILENT ACTUATING,
20-AMP, 120/277V, WHITE.
3. DIMMERS SHALL BE LEVITON SLIDING DIMMER
SWITCH, OF A RATING, VOLTAGE AND WATTAGE SUITABLE
FOR LOAD SERVED. COLORS OF DEVICES AND
COVERPLATES SHALL WHITE.
4. COMBINATION WALL DIMMER/OCCUPANT SENSOR
SHALL BE LUTRON MAESTRO 0-10V DIMMER WITH
INTEGRAL PASSIVE INFRARED OCCUPANT SENSING,
AVAILABLE IN 1-WAY OR 3-WAY CONFIGURATIONS.
COLOR TO BE WHITE. VERIFY LOAD SERVED IS
COMPATIBLE PRIOR TO ORDERING.
5. WIRING DEVICES SHALL BE SPECIFICATION GRADE.
6. COVERPLATES FOR POWER, DATA & TELEPHONE
SHALL BE LEVITON OR APPROVED EQUAL, WHITE, PLASTIC.
7. LIGHTING CONTRACTORS SHALL BE IN NEMA 1
ENCLOSURE, NORMALLY OPEN ELECTRICALLY HELD, 120V,
COIL, 20A. REFER TO PLANS FOR NUMBER OF POLES.
B. LIGHTING AND RECEPTACLE LOAD CENTERS (PANELS)
1.BRANCH CIRCUIT LOAD CENTERS SHALL BE DEAD FRONT
TYPE, WITH MAIN LUGS OR MAIN OVERCURRENT DEVICE
AS INDICATED, BRANCH OVERCURRENT DEVICES AS
NOTED AND AN EQUIPMENT GROUND BAR, ALL IN A
FLUSH MOUNTED SHEET STEEL ENCLOSURE. MINIMUM
SHORT CIRCUIT CAPACITY SHALL BE 10,000 AMPS
SYMMETRICAL FOR 120/208V, AND 14,000 AMPS
SYMMETRICAL FOR 277/480V APPLICATION UNLESS
NOTED OTHERWISE. LOAD CENTERS MUST BE SELECTED
TO FIT IN A STANDARD STUD WALL.
2. LOAD CENTERS SHALL BE AS MANUFACTURED BY
SQUARE D, GENERAL ELECTRIC, ITE/SIEMENS AND
WESTINGHOUSE/CUTLER HAMMER.
C. FIXTURES AND LAMPS
1.ALL FIXTURES AND LAMPS ARE FURNISHED BY TENANT,
INSTALLED BY ELECTRICAL CONTRACTOR..
D. FIRE ALARM SYSTEM
1.PROVIDED BY MACY'S.
PART 3 - EXECUTION
A. GENERAL MISCELLANEOUS
1.ALL CONDUIT RUN IN FINISHED AREAS SHALL BE
CONCEALED. 2.
2. PROVIDE TYPEWRITTEN DIRECTORY CARDS WITH
BRANCH CIRCUIT IDENTIFICATION FOR BRANCH CIRCUIT
PANELBOARDS. PANELBOARDS, FEEDER DEVICES,
DISTRIBUTION EQUIPMENT AND STARTERS SHALL BE FIELD
MARKED TO WARN QUALIFIED PERSONS OF POTENTIAL
ELECTRIC ARC FLASH HAZARDS IN ACCORDANCE WITH
NEC 110.16.
3. INSTALL HANDLE GUARDS ON ALL BREAKERS FOR
NIGHT LIGHTING, EMERGENCY AND SIMILAR CIRCUITS.
4. ALL FLUSH MOUNTED ;LOADCENTERS SHALL HAVE (3)
3/4" EMPTY CONDUITS INSTALLED TO ABOVE ACCESSIBLE
CEILING FOR FUTURE USE.
5. THE FINAL LOCATIONS OF ALL EQUIPMENT, OUTLETS,
ETC. SHALL BE SUBJECT TO REASONABLE CHANGES IN
LOCATION UP TO THE TIME OF ROUGHING-IN, AT NO
ADDITIONAL COST TO THE TENANT.
B. GROUNDING
1.GROUNDING OF THE ELECTRICAL SYSTEM SHALL BE BY
MEANS OF AN INSULATED GROUNDING CONDUCTOR
INSTALLED WITH ALL FEEDERS AND BRANCH CIRCUIT
CONDUCTORS IN ALL CONDUITS AND SUPPLEMENTAL AS
REQUIRED TO MEET CODE (SUCH AS ARTICLE 517).
C. TESTS
1.TEST FOR GROUNDS, SHORT CIRCUITS, AND PROPER
FUNCTION OF ALL EQUIPMENT AFTER INSTALLATION IS
COMPLETE. FAULTS IN THE INSTALLATION SHALL BE
CORRECTED AT NO COST TO THE TENANT.
D. DEMOLITION
1.DEMOLITION OF EXISTING ELECTRICAL EQUIPMENT, IF
APPLICABLE, SHALL BE PART OF THE ELECTRICAL WORK AS
INDICATED ON THE DRAWINGS.
CO
POS ROOM - ON 3RD LEVEL(LEVEL ABOVE CURRENT) -IDF3.
5
HVAC PLAN
SCALE: 1/4" = 1'-0"
1
TAG SERVICE MOUNTING MFR MODELNo. MODULE SIZE FINISH NOTES
S1 SUPPLYAIR
MATCHCEILING TITUS TMS 24" X 24" STD. WHITE
FINISH
R1 RETURNAIR
MATCHCEILING TITUS 50F 24" X 24" STD. WHITE
FINISH
NOTES/ACCESSORIES
1. RETAIL AREA OPEN TO MACY'S HVAC SYSTEM. NO WORK REQUIRED IN THIS AREA.2. EXISTING STORE SUPPLY AIR DUCTWORK TO REMAIN.3. CONNECT NEW SUPPLY AIR DUCTWORK TO EXISTING STORE SUPPLY AIR DUCTWORK AS
INDICATED.4. PROVIDE DAMPERS PER DETAIL IN DESIGN MANUAL. PROVIDE CABLE OPERATED DAMPERS WHERE
DAMPERS ARE INSTALLED OVER GYPSUM BOARD CEILING.5. PROVIDE DUCT TAKE OFFS PER DETAIL. HIGH EFFICIENCY FITTINGS SHALL BE USED. SEE DETAIL
IN DESIGN MANUAL6. INSULATE ALL SUPPLY DUCTWORK PER APPLICABLE ENERGY/MECHANICAL CODE - MOST
RESTRICTIVE TO GOVERN.7. EXISTING SUPPLY DIFFUSER AND DUCTWORK TO REMAIN.8. EXISTING AIR RETURN SHAFT TO REMAIN.9. EXISTING STORE EXHAUST TO UPPER LEVEL TO REMAIN.10. EXISTING TRANSITION DUCT TO AIR SHAFT TO REMAIN.11. EXISTING RETURN GRILLE TO REMAIN.
R2 RETURNAIR
MATCHCEILING TITUS 50F 12" X 24" STD. WHITE
FINISH
1
A. THE CONTRACT DOCUMENTS REFLECT A SYSTEM DESIGNED AROUND SPECIFIC REFERENCEPRODUCTS, THE SELECTION OF WHICH HAS IMPACTED THE DESIGNS OF OTHER TRADES. IFALTERNATE MANUFACTURERS ARE SUBMITTED OR BID, IT IS THE RESPONSIBILITY OF THIS G.C. TOCOORDINATE ALL DIFFERENCES AND IMPACTS WITH ALL TRADES PRIOR TO BID, INCLUDING COSTSASSOCIATED WITH REQUIRED CHANGES TO OTHER TRADES. NO EXTRAS WILL BE ALLOWED FORCHANGES REQUIRED TO OTHER TRADES IF ALTERNATE EQUIPMENT IS BID OR INSTALLED AT THEG.C.'S OPTION.
B. EXISTING MECHANICAL INFORMATION IS BASED ON LIMITED EXISTING BUILDING DRAWINGS AND FIELDWORK. THE G.C. SHALL FIELD VERIFY THE EXISTING CONDITIONS FOR ACCURACY. NO ADDITIONALCOMPENSATION SHALL BE ALLOWED FOR REVISIONS TO THE DESIGN TO CORRECT FOR EXISTINGCONDITIONS NOT AS INDICATED ON THE PLANS.
C. G.C. SHALL NOTIFY TENANT, ARCHITECT AND ENGINEER OF ANY SITUATIONS THAT MODIFY ORINCREASE THE SCOPE OF WORK FROM WHAT IS DESCRIBED IN THE DOCUMENTS.
D. G.C. SHALL BE RESPONSIBLE FOR ALL CUTTING/PATCHING RELATED TO THEIR WORK.
E. IF SPACE ABOVE CEILING IS INDICATED TO BE A RETURN AIR PLENUM, CONSTRUCTION MATERIALSABOVE CEILING SHALL BE NONCOMBUSTIBLE, OR HAVE A MAXIMUM 25 FLAME SPREAD AND 50 SMOKEDEVELOPMENT FINISH RATING. WIRING SHALL BE LABELED PLENUM RATED TYPE PER NFPA 70.
F. COORDINATE LOCATION AND ELEVATION OF MECHANICAL WORK WITH ALL DUCTWORK, LIGHTFIXTURES, AND OTHER CEILING BUILT-IN FIXTURES. CONTACT ENGINEER OR ARCHITECT IMMEDIATELYSHOULD ANY CONFLICT ARISE.
G. MOUNTING OF ALL EQUIPMENT, DUCTWORK AND PIPING MUST BE DONE PER BUILDING GUIDELINESAND LOCAL CODES AND INDUSTRY STANDARDS. COORDINATE INSTALLATION OF EQUIPMENTSUPPORT WITH BUILDING MANAGER AND NEXTORE REPRESENTATIVE.
H. NO PVC PIPING ALLOWED IN PLENUM AREAS.
I. DUCT SIZES INDICATED REPRESENT CLEAR INTERIOR SHEET METAL DIMENSIONS.
J. ALL DUCTWORK CONCEALED ABOVE CEILINGS, AND ALL OUTSIDE AIR DUCTS, SHALL BEEXTERNALLY INSULATED. IF DUCTWORK IS RUN IN A NON-CONDITIONED SPACE ALL DUCTWORK MUSTBE INSULATED WITH 2" FIBERGLASS INSULATION AND VAPOR BARRIER.
K. BRANCH DUCTS SERVING DIFFUSERS SHALL BE SIZED TO MATCH DIFFUSER NECK SIZE INDICATED.
L. ALL ROUND DUCT ELBOWS SHALL BE LONG SWEEP, 1-1/2 TIMES THE CENTERLINE RADIUS.
M. G.C. MUST REPLACE ALL AIR FILTERS IN HVAC UNITS WITH NEW CLEAN FILTERS BEFORE AIRBALANCING AND PRIOR TO FINAL TURNOVER TO TENANT.
N. IT IS THE G.C.'S RESPONSIBILITY TO ENSURE THAT THE MECHANICAL COMPONENTS ARE INSTALLEDAT LOCATIONS AND ELEVATIONS WHICH MAKE THEM READILY AND SAFELY ACCESSIBLE FOR ROUTINE MAINTENANCE WITHOUT REQUIRING ANY EXTRAORDINARY MEASURES.
O. THE TENANT RESERVES THE RIGHT TO CHECK CONSTRUCTION COMPLIANCE WITH PLANS ANDSPECIFICATIONS. SHOULD THE TENANT FIND CORRECTIVE WORK NECESSARY, HE WILL NOTIFY G.C. OFSUCH WORK IN WRITING AND EXPECT COMPLIANCE PERFORMED WITH DUE DILIGENCE. IF ANYCORRECTIVE WORK IS DEEMED TO BE NECESSARY, THE COST OF REINSPECTIONS WILL BE BORNE BYTHE G.C. IF WORK IS REQUIRED BY TENANT IN ORDER TO IMPROVE, CHANGE OR CORRECT AIRCONDITIONING OPERATIONAL CONDITIONS DUE TO: PART MALFUNCTION, WARRANTY OR OTHERINABILITY TO PROVIDE THE COMFORT CONDITIONS REQUIRED BY THE STORE, G.C. SHALL BE DIRECTEDBY TENANT TO ADDRESS THIS WORK IN A TIMELY MANNER. IF IT BECOMES EVIDENT THAT THE G.C. CANNOT ACCOMPLISH THE TASK, THEN AFTER 72 HOURS OF WRITTEN NOTICE, THE TENANT MAY AT HISDISCRETION TAKE OVER SUCH WORK AND BACK CHARGE THE G.C. FOR ANY CORRECTIVE WORK THATWAS REQUIRED DUE TO LACK OF PERFORMANCE, WORKMANSHIP AND/OR ADHERENCE TO PLANS AND SPECIFICATIONS.
P. DUCTWORK SHALL NOT BE ROUTED OVER ELECTRIC PANELS AND TRANSFORMER.
PLAN NORTH
GRILLE, REGISTER AND DIFFUSERSCHEDULE
1. PROVIDE NECK SIZE TO MATCH SUPPLY DUCTWORK ON DRAWINGS.2. TITUS CHOSEN, EQUALS ALLOWED.
TITUS
KEY NOTES - MECHANICAL PLANXX4
4-LCM-H200-REV 0.0
3
3-LCM-H200-REV 0.0
HVAC SYMBOLS1
POINT OF CONNECTION - NEW TO EXISTING
20x12
12"Ø
DIFFUSER/GRILLE LABEL:
B - NECK SIZE (INCHES)A - TYPE/DESIGNATION
C - AIRFLOW (CFM)
PATTERN. NO PATTERN SHOWN EQUALS 4-WAY.
FIRST NUMBER IS SIDE SHOWN.
ROUND DUCTWORK. DIAMETER IN INCHES.
RECTANGULAR DUCTWORK. SIZE IN INCHES,
SUPPLY AIR DIFFUSER - ARROWS INDICATE
RETURN AIR GRILLE
OR AS NOTED
MANUAL VOLUME DAMPER
SHEET KEYNOTE REFERENCE
BCA
#
2 GENERAL NOTES
1-LCM-H200-REV 0.0 2-LCM-H200-REV 0.0
STORE #8871
NORTH EAST MALL
1101 MELBOURNE RD. SUITE 3000
HURST, TEXAS 76053
1
5/17/2017 OWNERS COMMENTS
Seal
ByDateMark
Revisions:
a
ap
p
4000 Luxottica Place, Mason, OH 45040
6 Creamery Brook, East Granby, CT 06026
+1 (513) 765-6000
+1 (516) 393-2484
SheetDate
Drawn By
Checked By
Title
ISSUED FOR:
Nextore project
Number
Client Review
DOB Permit
DOB Permit - Re-Submit
Bid
Construction
LL Approval
Brand Design Type:
Construction for:
Nextore Store Design Revision No.:
DESIGN & CONSTRUCTION
MANAGEMENT:
74149
DESIGN REV 01
MODULAR
11/9/2017
STAFF
SRH
4000 Luxo
ttica Place M
aso
n, O
hio
45040
A Sub
sid
iary o
f the Luxo
ttica G
ro
up
Architect / Engineer Job No.:
LCM 012
Engineer of Record
2
11/10/2017 OWNERS COMMENTS
HVAC PLANS AND
DETAILS
H200
ROUNDDUCTWORK
45° LATERAL FITTING
RECTANGULARDUCTWORK
RECTANGULAR TO ROUND"BUCKLEY FITTING"
VARIES
2" MINIMUMCOLLAR
4"
RECTANGULAR TORECTANGULAR
CONICAL FITTING
ECCENTRIC REDUCER
CEILING DIFFUSER
DRAW BAND (TYP.)
HVAC DETAIL NOTES:SEE HVAC DRAWINGS FOR DUCT1.SIZES
SUPPLY AIR DUCT,INSULATE PER SPEC.
HIGH EFFICIENCY FITTING
INSULATED RIGID ROUNDDUCTWORK. INSULATION TOHAVE FOIL FACING (TYP.)INSULATED FLEX. DUCT (5FEET MAX.)
SHALL BE 1.5 x R,INSULATED 90 DEGREESHEET METAL ELBOW
ACOUSTICALCEILING
VOLUME DAMPERTO BE WITHIN 12"OF MAIN DUCT
BRANCH DUCT HEIGHTDIMENSION 2" LESS THANMAIN DUCT HEIGHTDIMENSION.
BALANCINGDAMPER
BALANCINGDAMPER
BALANCINGDAMPER
BALANCINGDAMPER
ROUNDDUCTWORK
RECTANGULARDUCTWORK
DUCT SIZE CROSS REFERENCE
GRILLE, SEE PLAN FOREGG CRATE TRANSFER
SIZES.
CEILING
VERIFY CEILING TYPE ONHVAC DETAIL NOTE:
ROOM FINISH SCHEDULE.
1'' DUCT LINER
LINE WITH 1"INSUL.GALVANIZEDSHEET METALDUCTWORK
SUPPORT TOSTRUCTUREABOVE (TYP.)
GRILLE, SEE PLAN FOREGG CRATE TRANSFER
SIZES.
WALL ASSEMBLY(TYP.)
TRANSFER RETURN AIR DETAIL
SCALE: NONE
A
BRANCH DUCT TAKE OFF DETAILS
SCALE: NONE
B
DUCT CONNECTION DETAIL
SCALE: NONE
C
XB-TOWEL
XB-TOWEL-C
11
8" DIA
R-2
R-2
7
S-1200
S-1200
S-1125
CLG. HT.=
PRETEST
102
10'-0"
CLG. HT.=
CONTACT LENS /
OPTICAL STATION
104
10'-0"
CLG. HT.=
RETAIL SALES AREA
100
10'-6 1/2"
CLG. HT.=
OD RECEPTION
/ WAITING
103
8'-0"
CLG. HT.=
REFRACTION
ROOM
101
10'-0" 3
4 5
8" D
IA
(TYP)
12" DIA
10" D
IA
8" DIA
8" DIA
2
1(TYP)
9
6(TYP)
162"X36"
16"X14"
8 2
68"X20"12" ROUND
12" FLEX
10
10
ELECTRICAL DEMOLITION PLAN
SCALE: 1/4" = 1'-0"
1
PLAN NORTH
"D" DEDICATED CIRCUIT"WP" INDICATES WEATHERPROOF COVER
"2" INDICATES CIRCUIT NUMBER
JUNCTION BOX
INFLOOR/UNDERFLOOR CONDUIT/WIRE
LIGHTING TIME CLOCK
a
"OS" INDICATES OCCUPANCY SENSOR SWITCH"C" INDICATES SWITCH MOUNTED 8" ABOVE COUNTER
"3" INDICATES THREE WAY SWITCH
FIRE ALARM SMOKE DETECTOR
FIRE ALARM VISUAL ONLY ALARM SIGNAL CEILING MOUNTED.
FIRE ALARM MANUAL PULL STATION MOUNTED AT 48" AFF.
FIRE ALARM AUDIO/VISUAL ALARM SIGNAL CEILING MOUNTED.
HOMERUN TO PANEL AND CIRCUIT INDICATED
"GFI" INDICATES GROUND FAULT CIRCUIT INTERRUPTER TYPE
DOUBLE DUPLEX RECEPTACLE - 125 VOLT, 2 POLE, 3 WIRE,GROUNDING TYPE, 20 AMPERE, MOUNTED AT 18" AFF UNLESSOTHERWISE NOTED.
"CLG" INDICATES MOUNTED IN CEILING
"D"
LIGHT FIXTURE: "AD" INDICATES FIXTURE TYPE "a" INDICATESSWITCH CONTROL. REFER TO LUMINAIRE SCHEDULE FORDESCRIPTION.
ILLUMINATED "EXIT" SIGN LIGHTING FIXTURE. CEILING MOUNTEDOR WALL MOUNTED. PROVIDE DIRECTIONAL ARROWS ASINDICATED ON FLOOR PLANS.
SWITCH - SINGLE POLE TOGGLE TYPE - 120/277 VOLT, 1-HPRATED, 20 AMPERE, MOUNTED AT 48" AFF UNLESS OTHERWISENOTED:
COMBINATION DUPLEX RECEPTACLE AND VOICE/DATA OUTLETMOUNTED IN FLOOR BOX.
DUPLEX RECEPTACLE - 125 VOLT, 2 POLE, 3 WIRE, 20 AMPEREMOUNTED IN FLOOR BOX.
DUPLEX RECEPTACLE - 125 VOLT, 2 POLE, 3 WIRE, GROUNDINGTYPE, 20 AMPERE, MOUNTED AT 18" AFF UNLESS OTHERWISENOTED:
DOUBLE DUPLEX RECEPTACLE - 125 VOLT, 2 POLE, 3 WIRE, 20AMPERE MOUNTED IN FLOOR BOX.
DATA OUTLET: MOUNTED AT 18" AFF UNLESS OTHERWISENOTED. PROVIDE SINGLE GANG BOX WITH PLASTER RING AND3/4" CONDUIT TO ABOVE THE ACCESSIBLE CEILING. "W"INDICATES WALL MOUNTED AT 54" AFF, "C" INDICATES MOUNTED8" ABOVE COUNTER. CLG INDICATES CEILING MOUNTED.
TC
SWITCHED WIRING
BRANCH CIRCUIT WIRING
HOMERUN
MOTOR
"E" EXISTING TO REMAIN
"4" INDICATES FOUR WAY SWITCH
INDICATES 0-10V DIMMER SWITCH - WATTAGE AS INDICATED ONPANEL SCHEDULE. EACH BRANCH CIRCUIT SHALL INCLUDE ASEPARATE NEUTRAL CONDUCTOR
"R" INDICATES RECESSED
FIRE ALARM DEVICES ARE ONLY SHOWN FOR PREFERENTIALLOCATION. FINAL LOCATIONS AND QUANTITIES SHALL BEDETERMINED BY LL AND FIRE ALARM ENGINEER- VERIFY PRIOR TOROUGH IN.
2 PORT DATA OUTLET
3 PORT DATA OUTLET
4 PORT DATA OUTLET
6 PORT DATA OUTLET
2
3
4
6
F
V
SD
F
FIRE ALARM SMOKE DETECTOR - DUCT MOUNTEDSD
XX-##
CIRCUITPANEL
CEILING MOUNTED OCCUPANT SENSOR
J
COMMUNICATIONS FLOOR BOX
S
OS
AD
D
#T-STL TRACK AND TRACK MOUNTED LIGHT FIXTURE (DESIGNATIONS
VARY - SEE PLANS)
RECESSED DOWNLIGHT. DESIGNATIONS VARY - SEE PLANS.
"OSD"INDICATES 0-10V DIMMER SWITCH WITH INTEGRAL PIR OCCUPANCYSENSOR - WATTAGE AS INDICATED ON PANEL SCHEDULE. EACH BRANCHCIRCUIT SHALL INCLUDE A SEPARATE NEUTRAL CONDUCTOR. 1 OR 3WAY AS INDICATED.
1 ELECTRICAL SYMBOLS(ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED ON THE DRAWINGS)
1-LCM-E100-REV 0.0
1. DISCONNECT AND REMOVE EXISTING DOWNLIGHT AND RETURN TO MACY'S OPERATIONS.
2. DISCONNECT AND REMOVE EXISTING STRIP FIXTURE AND RETURN TO MACY'S OPERATIONS.
3. EXISTING LIGHT FIXTURE IS TO REMAIN.
4. EXISTING SPEAKER TO REMAIN.
5. DISCONNECT AND REMOVE FLOOR RECEPTACLE. RE-POWER DEVICES TO REMAIN.
6. EXISTING SECURITY CAMERA TO REMAIN.
7. DISCONNECT AND REMOVE EXISTING RECEPTACLE. RE-POWER DEVICES TO REMAIN.
8. EXISTING RECEPTACLE TO REMAIN.
9. DISCONNECT AND RELOCATE EXISTING SECURITY DEVICE TO ABOVE CEILING.
KEY NOTES - ELECTRICAL DEMOLITION PLANXX2
2-LCM-E100-REV 0.0
"M" INDICATES A MASTER SWITCH THAT OVERRIDES THE OTHER SWITCHESCONNECTED TO IT.
3'-2
"A.F.F.
9 1
/2"
A.F.F.
STORE #8871
NORTH EAST MALL
1101 MELBOURNE RD. SUITE 3000
HURST, TEXAS 76053
1
5/17/2017 OWNERS COMMENTS
Seal
ByDateMark
Revisions:
a
ap
p
4000 Luxottica Place, Mason, OH 45040
6 Creamery Brook, East Granby, CT 06026
+1 (513) 765-6000
+1 (516) 393-2484
SheetDate
Drawn By
Checked By
Title
ISSUED FOR:
Nextore project
Number
Client Review
DOB Permit
DOB Permit - Re-Submit
Bid
Construction
LL Approval
Brand Design Type:
Construction for:
Nextore Store Design Revision No.:
DESIGN & CONSTRUCTION
MANAGEMENT:
74149
DESIGN REV 01
MODULAR
11/9/2017
STAFF
SRH
4000 Luxo
ttica Place M
aso
n, O
hio
45040
A Sub
sid
iary o
f the Luxo
ttica G
ro
up
Architect / Engineer Job No.:
LCM 012
Engineer of Record
2
11/10/2017 OWNERS COMMENTS
SPECIFICATIONS,
SYMBOLS, AND
DEMOLITION
E100
"TR" TAMPER RESISTANT
43
5 7
1
5 8
2
1
96
1
3
2
8
6 8
GS-LF71
GS-FN
07
GS-FN07
GS-FN
07
GS-FN07
1'-2
"
2'-0"
10 4 10
ELECTRICAL LEGENDDESCRIPTION#
1 MC CABLE, 12/2 w/GROUND, 12 AWG2 MC CABLE, 12/3 w/GROUND, 12 AWG3 4X4 JUNCTION BOX4 SEAL-TITE FLEXIBLE CONDUIT WHIP FROM POKE THRU TO J-BOX.5 DUPLEX 20A RECEPTACLE6 DOUBLE DUPLEX, 20A RECEPTACLE7 FED BY CIRCUIT #18 FED BY CIRCUIT #29 SINGLE GANG BOX WITHOUT A COVER FOR DATA (DATA WIRING BY OTHERS).
ELECTRICAL CONTRACTOR IS TO PROVIDE AND INSTALL ALL ELECTRICAL EQUIPMENTSHOWN IN THE DETAILS. NO WORK IS PROVIDED BY THE CASEWORKMANUFACTURER. THE DATA CABLING IS THE ONLY WIRING NOT IN THE ELECTRICALCONTRACTOR'S SCOPE.
ALL POWER WIRING IS TO BE IN METAL RACEWAY. SECURE RACEWAY TO INSIDE OFFURNITURE. COORDINATE WORK WITH THE GC.
10 ONE INCH CONDUIT STUB FROM FLOOR BOX/POKE THROUGH WITH PULL STRING
ELECTRICAL OUTLET INSTALLEDBY EC AT 15" AFF.
60WDRIVER
60W DRIVER
TO LEDs IN CASEWORK. WIRING,DRIVER AND LEDs ARE INSTALLED BYCASEWORK SUPPLIER.
EC TO PLUG DRIVERINTO RECEPTACLE
ELECTRICAL OUTLET INSTALLED BY EC AT 15" AFF.
TO LEDs IN CASEWORK. WIRING, DRIVER ANDLEDs ARE INSTALLED BY CASEWORK SUPPLIER.
PW-10 (2) 92" LED STRIP 42W (1) 60W DRIVER
42WTOTALPW-11 (1) 92" LED STRIP 21W (1) 60W DRIVER
21WTOTAL
GS-PW10GS-PW11
GS-PW01_CGS-PW01_R
GS-PW01_C
1'-118"1'-11
2"
EQ109B REFRACTION STAND 120 2.1
EQ108 PATIENT CARE N/A
EQUIPMENT ELECTRICAL/MECHANICAL REQUIREMENTSID DESCRIPTION VOLT AMP
X
BTU
REQUIRES DATA
NOTES
EQ119 2.1KERATOMETER 120 X X
EQ100A OPTOS
3GFI
120 3 X
EQ
118C
EQ6A
SE-OD01
SE-OD03SE-OD03
EQ109B
EQ108
EQ119
EQ6A 1LENSOMETER (AUTO) 120 X NEMA #5 - 20R
INSTALL RECESSEDOUTLET AT 72" AFF TOCENTERLINE
EQ103 LENSOMETER 120 1 X EQUIPMENT IS NOT IN USE IN THIS PLAN.
2
SE-OD01_L
18"
39"
18"
72"
6'-0
"E
LEC
TRIC
AL
OU
TLE
T
6 1/2"
6'-6
"E
QU
IPM
EN
T
OUTLINE OFRECESSED OUTLET
BOX.
CLCL
CL
CL
18"
ELEVATION
PLAN
ELEVATION
PLAN
ELEVATION
PLAN
SE-OD01 DOCTOR'S DESK
SE-OD03SE-OD03
GS-CL02_R
JGFI
18"
CONNECTIONFORTANKLESSWATERHEATER
GFI
LABEL
0401
0502
0603
LABEL
LABEL LABEL
LABEL LABEL
LABEL
1411
1512
1613
LABEL
LABEL LABEL
LABEL LABEL
LABEL
1411
1512
1613
LABEL
LABEL LABEL
LABEL LABEL
LF71W ELECTRICAL INFORMATION
SCALE: NONE
F
D
EQ21
5 0
2
LCGLB184200 ELECTRICAL INFORMATION
SCALE: NONE
E
EQ121
EQ120
REFRACTION (EXAM) ROOM ELECTRICAL INFORMATION
SCALE: NONE
A
CLO2 ELECTRICAL INFORMATION
SCALE: NONE
B
PW10/PW11 AND 0400/0420 ELECTRICAL INFORMATION
SCALE: NONE
C
CASEWORK ELECTRICAL (INSTALLEDBY CASEWORK SUPPLIER)
EQ101 TONOMETER 120 1
EQ102 REFRACTOMETER 120 1
EQ104 0.5VISION TESTER 120
EQUIPMENT ELECTRICAL/MECHANICAL REQUIREMENTSID DESCRIPTION VOLTAMP
X
X
X
BTU NOTESEQ100C TRIPLE POWER 120 1 X
E
Q
1
0
5
C
EQ100C
EQ101
E
Q
10
2
EQ105C 1.1OCULUS 120 X
18" AFF
EQ
UA
LE
QU
AL
TABLETHIS TABLE PLUGS INTOTHE WALLTHIS EQUIPMENT PLUGSINTO EQ100CTHIS EQUIPMENT PLUGSINTO EQ100CTHIS EQUIPMENTPLUGS INTO EQ100CTHIS EQUIPMENT PLUGSINTO EQ100C EQUIPMENT ISNOT IN USE IN THIS PLAN.
PRETEST ELECTRICAL INFORMATION
SCALE: NONE
D
1'-9"1'-1"
1'-0
"1'
-3"
1'-6
"
3'-4"1'-3"
1'-9
"
3 EX3 EX
3 EX 3 EX
3EX3 EX
3
EX
3
EX
3
EX
3
EX
3
EX
3
EX
3
EX
3
EX
3
EX
3
EX
3
EX
2
2
2
2
2
2
2
2
2
2
2
2
2
2
22
2
23
EX
3
EX
3
EX
5
5
5
5
5
5
8
8
7
7
4
1
6SC
EQ EQ
SEE ARCH DWGS
12"
28"43"
13" 41"4'
-0"
912"
0451 ELEC. INFO.
SCALE: NONE
G
SEE SHEET A100
FOR C.L. DIM.
5'-3"
0821-00
LCM-MW-CS.2
0820-00 & XB-DFQ55
0835-00
C
L
IN WALL:
(2) ARLTVBU505BL -
ARLINGTON™ TVBU505BL
TWO-GANG RECESSED
ELECTRICAL BOX (BLACK)
(OR EQUAL BLACK IN COLOR)
PROVIDE IN WALL (2)
3
4
"
CONDUIT FROM
IN-WALL BOX TO 6"
ABOVE CEILING.
ELECTRICAL CONTRACTOR TO
PROVIDE ONE 20A, 120V UNSWITCHED
CIRCUIT TO ONE (1) DUPLEX
RECEPTACLE AND (1) QUAD
RECEPTACLE. ELECTRICAL
CONTRACTOR TO PROVIDE RACEWAY
AND BOX FOR DATA OUTLET.
1'-0"
9"
1'-8"
BACKWRAP 0821 ELECTRICAL INFORMATION
SCALE: NONE
H
3'-0"
9
POWER AND LOW VOLTAGE PLAN
SCALE: 1/4" = 1'-0"
2
PLAN NORTH
LIGHTING PLAN
SCALE: 1/4" = 1'-0"
1
PLAN NORTH
1. LIGHTING IN THIS AREA IS FROM MACY'S STORE.
2. LOCATION OF LIGHTING CONTACTORS. INSTALL ABOVE THE CEILING WHERE PERMITTED BYCODE. SEE DETAIL.
3. PROVIDE CURRENT LIMITER FOR TRACK FROM MANUFACTURER'S SELECTION, SIZED ASINDICATED. FINISH OF CURRENT LIMITER TO MATCH TRACK FINISH.
4. SUPPLEMENTAL SALES FLOOR LIGHTING IS TO BE CONTROLLED BY THE MACY'S TIMECLOCKSYSTEM.
XX4 KEY NOTES - LIGHTING PLAN
3-LCM-A200-REV 0.0
LIGHT
D
UNSWITCHED CIRCUIT
S DIMMER. SUPPLIED BY TENANT0-10V, 1-WAY/3-WAY, WHITE
WALL SENSOR/DIMMER/MASTER SWITCHCOMBINATION
S M/OSOCCUPANCY SENSOR WALLSWITCH (SUPPLIED BY TENANT)OPERATES AS MASTER.
LIGHT
OSD
UNSWITCHED CIRCUIT
S
OSD: OCCUPANT SENSINGDIMMER. SUPPLIED BY TENANT,0-10V, 1-WAY/3-WAY, WHITE
WALL SENSOR/DIMMER COMBINATION
OCCUPANCY SENSOR SCHEMATICS
SCALE: NONE
B
1. PROVIDE DIRECT CONNECTION IN WALL TO SERVE TANKLESS WATER HEATER. CONNECTION TO BE 25A,120V, SINGLE PHASE. CIRCUIT AS INDICATED. COORDINATE LOCATION WITH PLUMBING CONTRACTOR.
2. PROVIDE CORE DRILLING FOR POWER AND TELE/DATA TO SELECT TABLE. E.C. SHALL VERIFY ALL COREDRILLING REQUIREMENTS WITH THE LANDLORD PRIOR TO THE START OF WORK. PROVIDE DEVICES ANDDEVICE QUANTITIES AS SPECIFIED ON PLANS. E.C. SHALL COORDINATE INSTALLATION AND CONNECTIONREQUIREMENTS WITH FURNITURE MANUFACTURER REPRESENTATIVE.
3. PROVIDE "FURNITURE" FLOOR BOX/POKE THRU AT THIS LOCATION - SEE DETAIL AND THE DATAINTERCONNECTION RISER.
4. INSTALL OUTLET AT BACKWRAP FOR FRAME WARMER. VERIFY LOCATION OF OUTLET WITH NEXTOREPROJECT MANAGER PRIOR TO ROUGH IN.
5. PROVIDE JUNCTION BOX ABOVE CEILING FOR LENSCRAFTERS SIGN.
6. VERIFY MOUNTING HEIGHTS OF OUTLETS WITH NEXTORE PROJECT MANAGER PRIOR TO ROUGH IN.
7. CONNECT CIRCUIT TO MACY'S LIGHTING CONTROL SYSTEM. SEE DETAIL. VERIFY SPECIFIC REQUIREMENTSWITH MACY'S.
8. PROVIDE RECESSED RECEPTACLE AT ELEVATION SHOWN ON ARCHITECTURAL SHEETS FOR POWER TODIGITAL EYE CHART.
9. ROUTE ONE 3/4" CONDUIT TO ABOVE CEILING FROM EMPTY 4X4 JUNCTION BOX WITH MUDRING INSTALLED ATHEIGHT EQUIVALENT TO ADJACENT POWER OUTLET. BUSH CONDUIT END AND PROVIDE PULL STRING.
10. ROUTE CONDUIT 6" ABOVE CEILING AND BUSH END. TYPICAL.
11. ROUTE ONE 1" CONDUIT FOR POWER AND TWO 1" CONDUITS FOR DATA. SEE DATA INTERCONNECTION RISER.PROVIDE PULL STRING. TYPICAL.
12. RECEPTACLE AND DATA OUTLET SERVES DIGITAL SIGNAGE. SEE ELEVATION ON ARCHITECTURAL SHEETS.VERIFY EXACT LOCATION OF ROUGH IN WITH NEXTORE PROJECT MANAGER PRIOR TO ROUGH IN.
13. CASEWORK TO BE FIELD WIRED BY ELECTRICAL CONTRACTOR. SEE DETAIL.
14. PROVIDE NEC 517 REDUNDANT GROUNDING FOR RECEPTACLES AND SWITCHES/DIMMERS IN THIS ROOM.
PROVIDE BONDING TO ALL METAL PARTS OF THE RACEWAY SYSTEM TO ENSURE THAT THE RACEWAYSYSTEM ACTS AS A GROUNDING PATH, AND PROVIDE A SEPARATE GROUNDING CONDUCTOR. BOND THE
CONDUCTOR AND THE RACEWAY TO THE RECEPTACLES TO CREATE A REDUNDANT PATH TO GROUND. USE
HOSPITAL GRADE MC CABLE WHEN MC CABLE IS THE WIRING METHOD USED.
15. SEE DATA RISER DIAGRAM FOR ARRANGEMENT OF OUTLETS FOR THE DATA CABINET.
16. DO NOT INSTALL ELECTRICAL PANEL BELOW EXISTING DUCTWORK. VERIFY DUCTWORK LOCATION IN FIELDAND ADJUST PANEL LOCATION AS NECESSARY. COORDINATE WITH NEXTORE PROJECT MANAGER.
17. EXISTING SECURITY EQUIPMENT TO REMAIN. RELOCATED TO ABOVE CEILING.
KEY NOTES - ELECTRICAL PLANXX3
2-LCM-A200-REV 0.0
SEE DATA INTERCONNECTIONRISER ON E300 FORADDITIONAL INFORMATION.
LOAD CENTER "A"
NOTE: ALL WIRING BY THE ELECTRICAL CONTRACTOR.
STORE #8871
NORTH EAST MALL
1101 MELBOURNE RD. SUITE 3000
HURST, TEXAS 76053
1
5/17/2017 OWNERS COMMENTS
Seal
ByDateMark
Revisions:
a
ap
p
4000 Luxottica Place, Mason, OH 45040
6 Creamery Brook, East Granby, CT 06026
+1 (513) 765-6000
+1 (516) 393-2484
SheetDate
Drawn By
Checked By
Title
ISSUED FOR:
Nextore project
Number
Client Review
DOB Permit
DOB Permit - Re-Submit
Bid
Construction
LL Approval
Brand Design Type:
Construction for:
Nextore Store Design Revision No.:
DESIGN & CONSTRUCTION
MANAGEMENT:
74149
DESIGN REV 01
MODULAR
11/9/2017
STAFF
SRH
4000 Luxo
ttica Place M
aso
n, O
hio
45040
A Sub
sid
iary o
f the Luxo
ttica G
ro
up
Architect / Engineer Job No.:
LCM 012
Engineer of Record
2
11/10/2017 OWNERS COMMENTS
LIGHTING, POWER
AND LOW
VOLTAGE PLANS
E200
1. COMMISSIONING AGENT TO CONFIRM THE FOLLOWING IN THE OFFICE AREA:
1.1. OCCUPANCY SENSORS DETECT MOTION AND ENERGIZE THE LOCAL SWITCHING.
1.2. LOCAL SWITCHING IS DIMMABLE, ALLOWING A RANGE OF DIMMING FROM 5% TO 100%.
1.3. OCCUPANCY SENSORS DE-ENERGIZE AFTER NO MOTION IS DETECTED AFTER A 30 MINUTE DELAY.
2. COMMISSIONING AGENT TO CONFIRM THE FOLLOWING IN THE SALES AREA:
2.1. SIGNS, PERIMETER SHELVING AND SALES FLOOR DISPLAY CABINETS ARE ENERGIZED AND
DE-ENERGIZED WITH THE MACY'S DISPLAY LIGHTING CONTROL.
2.2. SUPPLEMENTAL TRACK LIGHTING IS LIMITED TO 125% OF THE CONNECTED WATTAGE OF TRACK
HEADS.
2.3. SUPPLEMENTAL TRACK LIGHTING IS CONTROLLED WITH THE MACY'S ACCENT LIGHTING CONTROL.
ENERGY CODE - COMMISSIONING
TOMONOPOINTS
CURRENT LIMITING ENDFEED
END FEED USED IN REVERSE TOSUPPLY NEXT TRACK SECTION WHENTRACK IS SEPARATED, AND TO SUPPLYMONOPOINT FIXTURES.
END FEED TO SUPPLYTRACK SECTION.
TRACK SECTION TRACK SECTION TRACK SECTION
END FEED USED IN REVERSE TOSUPPLY NEXT TRACK SECTION WHENTRACK IS SEPARATED, AND TO SUPPLYMONOPOINT FIXTURES.
END FEED TO SUPPLYTRACK SECTION.
TRACK WIRING DETAIL
SCALE: NONE
A
A. ELECTRICAL CONTRACTOR TO PROVIDE ALL RACEWAY AND BOXES AND A 120V SUPPLYTO THE FIRE ALARM POWER EXTENDER.
B. TENANT WILL CONTRACT DIRECTLY WITH MACY'S REQUIRED CONTRACTOR FOR DEVICES,WIRING, AND PROGRAMMING.
C. FIRE ALARM SUBMITTAL WILL BE PROVIDED TO THE JURISDICTION FROM THE MACY'SFIRE ALARM VENDOR AS A DEFERRED SUBMITTAL UNDER A SEPARATE PERMIT.
D. FIRE ALARM VENDOR IS:
1 GENERAL NOTES - FIRE ALARM
4-LCM-E100-REV 0.0
AN EXISTING FIRE ALARM SYSTEM WITH NOTIFICATION APPLIANCES IS NOT PRESENT.NOTIFICATION APPLIANCES ARE NOT BEING PROVIDED FOR THE NEW LENSCRAFTERS SPACE.
AN EXISTING FIRE ALARM SYSTEM WITH NOTIFICATION APPLIANCES IS PRESENT.NOTIFICATION APPLIANCES ARE BEING PROVIDED FOR THE NEW LENSCRAFTERS SPACE.
A. IT SHALL BE THE E.C.'S RESPONSIBILITY TO UNLOAD INVENTORY AND STORE LIGHTINGPACKAGE. THE E.C. SHALL ALSO SHIP ANY EXCESS MATERIALS BACK TO THE ELECTRICALPACKAGE DISTRIBUTOR.
B. EXIT LIGHTS AT THE STOREFRONT SHALL BE CEILING MOUNTED AND CENTERED OVEROPENINGS. EXIT/EMERGENCY LIGHTS AT DOOR TO NON-SALES AREAS SHALL BE CEILINGMOUNTED AND CENTERED ABOVE DOOR. IF PLAN LOCATIONS ARE NOT ACCEPTABLE,IMMEDIATELY CONTACT LUXOTTICA PROJECT MANAGER FOR DIRECTION.
C. WHERE DRYWALL CEILINGS ARE USED IN THE SALES AREA, E.C. SHALL ARRANGE CIRCUITS TOAVOID THE USE OF JUNCTION BOXES IN INACCESSIBLE LOCATIONS. THE USE OF JUNCTIONBOXES ABOVE DRYWALL CEILINGS SHALL BE LIMITED TO LOCATIONS NEAR ACCESS FRAMESUSED FOR DIFFUSERS AND RETURN AIR GRILLES OR ACCESS PANELS AS LOCATED ON PLANS.IF PLAN LOCATION IS NOT ACCEPTABLE, IMMEDIATELY CONTACT LUXOTTICA PROJECTMANAGER FOR DIRECTION.
D. E.C. SHALL RELAMP ALL FIXTURES PRIOR TO STORE OPENING BUT NOT DURING HEAVYCONSTRUCTION PERIOD.
E. LIGHTING CIRCUITS UP TO 100'-0" IN LENGTH SHALL UTILIZE #12 CONDUCTORS MINIMUM.LIGHTING CIRCUITS FROM 101'-0" TO 150'-0" IN LENGTH SHALL UTILIZE #10 CONDUCTORSMINIMUM. LIGHTING CIRCUITS FROM 151'-0" TO 250'-0" IN LENGTH SHALL UTILIZE #8CONDUCTORS MINIMUM. LIGHTING CIRCUITS ABOVE 251'-0" IN LENGTH SHALL UTILIZE #6CONDUCTORS MINIMUM.
F. E.C.'S BID SHALL INCLUDE THE INSTALLATION OF ALL LUMINAIRES AND ASSOCIATED LAMPSFURNISHED BY NEXTORE. E.C. IS RESPONSIBLE TO ENSURE THE ADJUST ABILITY OF ALLDIRECTIONAL FIXTURES AFTER INSTALLATION AND SHALL AIM THE FIXTURES PER DIRECTIONFROM G.C. LIGHT FIXTURE SPECIFICATIONS MAY VARY, IF THIS IS THE CASE, CONTRACTORSHALL CALL THE LIGHTING DISTRIBUTOR FOR EXACT SPECIFICATION OF LIGHTING FIXTURES. IFTHE CEILING SYSTEMS ARE FIRE RATED, E.C. SHALL CLOSELY COORDINATE FIXTUREREQUIREMENTS WITH LUXOTTICA.
G. E.C. SHALL MAKE ALL FINAL CONNECTIONS AS REQUIRED FOR A FULLY COMPLETE ANDOPERABLE SYSTEM.
H. E.C. SHALL VERIFY THE VOLTAGE AND COMPATIBILITY OF ALL EQUIPMENT, FIXTURES ANDMILLWORK PRIOR TO CONNECTION.
I. ALL MOUNTING HEIGHTS FROM THE CENTERLINE OF THE BOX TO THE FINISHED FLOOR ARE ASFOLLOWS, UNLESS NOTED OTHERWISE ON PLAN: SWITCHES-48",ELECTRICAL/TELEPHONE/DATA OUTLETS-18", TOP OF PANELBOARDS-6'-6", TIMECLOCKS-5'-0".FOR ALL LENS PROCESSING ROOM OUTLET MOUNTING HEIGHTS SEE EQUIPMENT WIRINGSCHEDULE.
J. FLEXIBLE CONDUIT SHALL BE USED FOR ALL FINAL CONNECTIONS TO MILLWORK, INTERIORLIGHTING FIXTURES, AND EQUIPMENT. MAXIMUM LENGTH OF FLEXIBLE CONDUIT SHALL BE12'-0".
K. IF INSTALLATION VARIES FROM THE CONTRACT DRAWINGS, THE GENERAL CONTRACTOR WILLBE RESPONSIBLE FOR OBTAINING "AS BUILT" DRAWINGS FROM THE SUBCONTRACTORS ANDSUBMITTING SAME TO NEXTORE PROJECT MANAGER.
L. IT IS THE E.C.'S RESPONSIBILITY TO PROPERLY BALANCE ALL BRANCH CIRCUITS BETWEENTHE PHASES OF THE SYSTEM (WITH-IN 10%).
M. ALL WORK SHALL BE IN STRICT ACCORDANCE WITH NATIONAL ELECTRICAL CODE AND ALLLOCAL CODES AND ORDINANCES.
N. ALL OUTLETS IN THE LENS PROCESSING ROOM ARE TO BE LABELED WITH PANEL AND CIRCUITNUMBER.
O. THE E.C. SHALL VERIFY THE VOLTAGE AND COMPATIBILITY OF ALL EQUIPMENT, FIXTURES ANDMILLWORK PRIOR TO CONNECTION.
P. SEE DATA RISER ON THIS SHEET FOR ADDITIONAL INFORMATION.
Q. PROVIDE POWER, TELEPHONE AND DATA CONDUIT WITHIN FLOOR, BETWEEN FIXTURE ANDNEAREST WALL AS INDICATED ON PLANS. METHOD OF CORE DRILLING SHALL BE PER BUILDINGREQUIREMENTS. ALL CORE DRILL REQUIREMENTS SHALL BE VERIFIED WITH LANDLORD.CONTRACTOR SHALL SIZE CONDUIT PER NEC. PROVIDE FOR X-RAY OF FLOOR WHEREREQUIRED BY THE LANDLORD.
2 GENERAL NOTES
3-LCM-E100-REV 0.0
POKETHRUFITTING
FLOORBOX
SUBPLATES
COVER /FLANGE
BOX CALL OUT ON PLANS
SYSTEMONE FLOORBOX HUBBELLCFBS1R4PFB W/CUP
SYSTEMONESUB-PLATES1R4SP2X2DUPLEX
CFBS1R4CVRALU(CARPET)
RECESSED
TWO DUPLEXRECEPTACLES ANDONE DATA OUTLET
6CTC2AL (CARPET) /6CT2AL (TILE)
RECESSED
WIREMOLDEVOLUTION 6ATSERIES POKE THRU
FURNITURE
SYSTEMONEFLOOR BOXHUBBELL S1PFB
SYSTEMONESUB-PLATEHUBBELL S1SPFFAL
S1PTFITPOKE THRU
120V
CONTACTOR TO BE SQUARE D OR EQUAL, 20A CONTACTS,ELECTRICALLY HELD IN NEMA1 ENCLOSURE. INSTALLABOVE CEILING WHERE PERMITTED BY CODE.
CASEWORK AND SIGNS
WALL SHELF LIGHTING
SEE PLANS
SEE PLANS
LOAD DESCRIPTION CIRCUIT
COIL
CONNECT TO NEAREST MACY'S 120VMERCHANDISE LIGHTING CIRCUIT SWITCHEDWITH MACY'S LIGHTING CONTROL SYSTEM.
120V
CONTACTOR TO BE SQUARE D OR EQUAL, 20A CONTACTS,ELECTRICALLY HELD, IN NEMA1 ENCLOSURE. INSTALLABOVE CEILING WHERE PERMITTED BY CODE.
SUPPLEMENTAL SALES LIGHTING SEE PLANSLOAD DESCRIPTION CIRCUIT
COIL
CONNECT TO NEAREST MACY'S 120VSALES FLOOR ACCENT LIGHTINGCIRCUIT SWITCHED WITH MACY'SLIGHTING CONTROL SYSTEM. NOTEWHERE ACCENT LIGHTING IS 277V, USEA 277V COIL.
GENERALLY, THE LIGHTING CONTROL SYSTEM IS PRESENT IN ANY MACY'S ELECTRIC ROOMS. VERIFY IN FIELD.VERIFY EXACT REQUIREMENTS WITH MACY'S OPERATIONS.MICHIGAN AND TOLEDO MACY'S STORES USE ANDOVER CONTROLS (GENERALLY) AND INET (RARELY).
CONNECTION TO BUILDING AUTOMATION SYSTEM
SCALE: NONE
DFLOOR BOX SCHEDULE
SCALE: NONE
C
ADAD
AD AD
AD-EM
AD AD
EXEX
EX EX
EXEX
EX
EX
EX EX
EX
EX
EX
EX
EXEXEX
EX
EX
6T-S
6T-S
6T-S
TL
TL
TL
TL
TL
TL
TL
TL
TL
TL
TL
TL2 TL2
TL2
TL2
TL2
TL2
EX
3
A-2
4
CURRENTLIMITER TORESTRICT TO480W
SDM/OS
S
2
S
OSDX2
S
OSD
1(TYP)
SD
M/OS
S
CLG. HT.=
PRETEST
102
10'-0"
CLG. HT.=
CONTACT LENS /
OPTICAL STATION
104
10'-0"
CLG. HT.=
REFRACTION
ROOM
101
10'-0"
CLG. HT.=
RETAIL SALES AREA
100
10'-6 1/2"
CLG. HT.=
OD RECEPTION
/ WAITING
103
8'-0"
SC
EX
EX
EX
EX
5 0A-14A-14
15
A-7 A-172
INSTALL ABOVECOUNTER
10
5
A-19,21
2 3
A-19,21
1311
6'-8"
14'-8"
A-21
12
1
4
A-18A-18
48" AFFA-21
7
J5
A-37
6(TYP)
6(TYP)
J
1
A-63
A-22
A-6TR
TR
A-13
A-13
8
14
TR
A-15
J9
14
2 A-6TR
TR
A-4J A-24
GFI
1
5
A-10
A-10 F
V
CLG. HT.=
RETAIL SALES AREA
100
10'-6 1/2"
CLG. HT.=
CONTACT LENS /
OPTICAL STATION
104
10'-0"
CLG. HT.=
PRETEST
102
10'-0"
CLG. HT.=
OD RECEPTION
/ WAITING
103
8'-0"
CLG. HT.=
REFRACTION
ROOM
101
10'-0"
17 D
2T-S
TLTL
SIMPLEX, CONTACT: BRUCE KELLING ([email protected];978-731-8786)
3
TR
TR
A-1
A-3
F
16
DESIGN DRAWINGS ARE SCHEMATIC. THE GENERALCONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING ORAWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS.THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALSNECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTINGCONDITIONS.
THE GENERAL CONTRACTOR SHALL CONTACT THE ARCHITECT,ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONSAND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BIDALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADEBY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILLBE FINAL AND SHALL BE IMPLEMENTED AT GENERALCONTRACTORS COST.
BIDDING GENERAL CONTRACTORS SHALL HAVE A WORKINGKNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALLINCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED INSTRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS ANDSPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALLALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENTDISCREPANCIES BETWEEN GOVERNING CODES AND DESIGNINTENT.
1. THE ELECTRICAL CONTRACTOR SHALL VERIFY ALLLANDLORD REQUIREMENTS PRIOR TO BIDDING & INCLUDETHE COST OF ALL ASSOCIATED LABOR, MATERIALS, &CHARGES IN HIS BID.
2. THE ELECTRICAL CONTRACTOR SHALL VERIFY THEAVAILABLE FAULT CURRENT WITH THE LANDLORD PRIOR TOBIDDING AND PROVIDE EQUIPMENT RATED ACCORDINGLY.SUBMIT FAULT CURRENT CALCULATIONS WITH SHOPDRAWING SUBMITTAL.
3. PROVIDE NAMEPLATES PER NAMEPLATE DETAIL.
4. COORDINATE SPACE WITH ALL OTHER TRADES TO MAINTAINALL CODE- REQUIRED CLEARANCES.
5. REFER TO ELECTRICAL SPECIFICATIONS FOR ADDITIONALREQUIREMENTS.
6. THE ELECTRICAL CONTRACTOR SHALL COMPLY WITH NECARTICLE 110.16 FOR LABELING OF PANELS FOR ARC FLASHHAZARD WARNING AS WELL AS FOLLOWING REQUIREDSAFETY PRECAUTIONS WHEN SERVICING OR MAINTAININGELECTRICAL EQUIPMENT.
3-LCM-E300-REV 0.0
4
2
ONE-LINE DIAGRAM NOTES
ELECTRIC ONE-LINE DIAGRAM
FIELD VERIFY ALL CONDITIONS
3
1-LCM-E300-REV 0.0
2-LCM-E300-REV 0.0
KEY NOTES:
ENGRAVED LAMACOID, 5/32"LETTERS, SECURE TO PANELBOARD COVER WITH ADHESIVETYPE FASTENER.
LENSCRAFTERSMACY'S ELECTRIC ROOM
NEWPANEL "A"120/208V3Ø 100A
MLO
(4)#6, (1)#8 GND IN 1 1/4" C.
A
WHERE PERMITTED BY THE JURISDICTIONAND LANDLORD, MC CABLE CAN BE USED FORTHIS INSTALLATION.
1. UTILIZE EXISTING PANEL FOR THE 60A FEED TO NEW LOADCENTER "A" IN THE LENCRAFTER'S SPACE. VERIFY CURRENTLOAD ON EXISTING PANEL AND REPORT TO ENGINEER TOCONFIRM PANEL CAPACITY.
LOAD CENTER CONSTRUCTION TO FITIN STANDARD STUD WALL.COORDINATE WITH GENERALCONTRACTOR.
60/3
STORE #8871
NORTH EAST MALL
1101 MELBOURNE RD. SUITE 3000
HURST, TEXAS 76053
1
5/17/2017 OWNERS COMMENTS
Seal
ByDateMark
Revisions:
a
ap
p
4000 Luxottica Place, Mason, OH 45040
6 Creamery Brook, East Granby, CT 06026
+1 (513) 765-6000
+1 (516) 393-2484
SheetDate
Drawn By
Checked By
Title
ISSUED FOR:
Nextore project
Number
Client Review
DOB Permit
DOB Permit - Re-Submit
Bid
Construction
LL Approval
Brand Design Type:
Construction for:
Nextore Store Design Revision No.:
DESIGN & CONSTRUCTION
MANAGEMENT:
74149
DESIGN REV 01
MODULAR
11/9/2017
STAFF
SRH
4000 Luxo
ttica Place M
aso
n, O
hio
45040
A Sub
sid
iary o
f the Luxo
ttica G
ro
up
Architect / Engineer Job No.:
LCM 012
Engineer of Record
2
11/10/2017 OWNERS COMMENTS
RISER AND DETAILS
E300
SYMBOL TYPE MANUFACTURER PART-NUMBER INPUT WATTS LAMP QTY LAMP TYPE DESCRIPTION MOUNTING CEILING TYPE
AD- EM METALUX 22ALNG-LD4-35-UNV-L835-CD1-U-EL14W
34.5 N/A INTEGRAL LED, 3482 LUMENS14W EMERGENCY - 1400 LUMENS
RECESSED 2X2 LED TROFFER WITH EMERGENCYBATTERY BACKUP.
RECESSED ACT
X2 LIGHT ALARMS SPLEDWRCD 3 N/A LED INCLUDED
RECESSED EXTRUDED ALUMINUM EDGE LIT EXIT SIGNWITH RED LETTERS FOR CEILING OR WALL MOUNTING
RED LED INCLUDED. TO BE RECESSED MOUNTEDU.N.O. (FOR NYC OR CHICAGO CONFIRM WITH MANUF).
PROVIDE CURRENT LIMITER WHERE REQUIRED.
X2
AD-EM
TRACK ONLY - SEE TRACK HEAD2T-S JUNO T2WH - -
LIGHTING SCHEDULE
TL
2T-S
4T-S
6T-S
8T-S
AD METALUX
22ALNG-LD4-35-UNV-L835-CD1-U-OCC/DIMMER
(TOTAL QTY AS NOTED INSCHEDULE NOTE #2)
34.5 N/A INTEGRAL LED, 3482 LUMENS
RECESSED 2X2 LED TROFFERSUPPLIER TO PROVIDE OCC SENSORS,
COMBINATION SENSORS/DIMMERS, AND 0-10VDIMMERS, WHITE IN COLOR, WITH FIXTURE
PACKAGE. SEE NOTE #2 AT BOTTOM OF SCHEDULE
RECESSED ACTAD
2 FT LONG, SINGLE CIRCUIT, WHITE TRACK
TRACKTL JUNO T690WH 18 1 GIMBAL STYLE LAMP-HOLDER, WHITE
TRACK ONLY - SEE TRACK HEAD4T-S JUNO T4WH - - 4 FT LONG, SINGLE CIRCUIT, WHITE TRACK
TRACKTL JUNO T690WH 18 1 GIMBAL STYLE LAMP-HOLDER, WHITE
TRACK ONLY - SEE TRACK HEAD6T-S JUNO T6WH - - 6 FT LONG, SINGLE CIRCUIT, WHITE TRACK
TRACKTL JUNO T690WH 18 1 GIMBAL STYLE LAMP-HOLDER, WHITE
TRACK ONLY - SEE TRACK HEAD8T-S JUNO T8WH - - 8 FT LONG, SINGLE CIRCUIT, WHITE TRACK
TRACKTL JUNO T690WH 18 1 GIMBAL STYLE LAMP-HOLDER, WHITE
12T-S TRACK ONLY - SEE TRACK HEAD12T-S JUNO T12WH - - 12 FT LONG, SINGLE CIRCUIT, WHITE TRACK
GE LED18D38W3930/25; 18W; 92 CRI;3000K; PAR38, MED BASE
TRACKTL JUNO T690WH 18 1 GIMBAL STYLE LAMP-HOLDER, WHITE
GE LED18D38W3930/25; 18W; 92 CRI;3000K; PAR38, MED BASE
GE LED18D38W3930/25; 18W; 92 CRI;3000K; PAR38, MED BASE
GE LED18D38W3930/25; 18W; 92 CRI;3000K; PAR38, MED BASE
GE LED18D38W3930/25; 18W; 92 CRI;3000K; PAR38, MED BASE
TL
TL
TL
TL
SEE FOOTNOTE 1
SEE FOOTNOTE 1
SEE FOOTNOTE 1
SEE FOOTNOTE 1
SEE FOOTNOTE 1
FOOTNOTES:1. SEE PLANS FOR TRACK LOCATIONS. PROVIDE CURRENT LIMITERS AND PENDANTS WHERE CALLED FOR ON THE PLANS.2. SUPPLIER TO PROVIDE 0-10V DIMMERS WITH FIXTURE PACKAGE. SEE PLANS FOR EXACT QUANTITIES. DIMMERS TO BE INSTALLED BY ELECTRICAL CONTRACTOR
1
1-LCM-A200-REV 0.0
X2/EM LIGHT ALARMS UQLXN500-R-2LED-R 4 N/A LED INCLUDED
SURFACE EXIT SIGN, POLYCARBONATE, REDLETTERS, 2 LED 3.6V, 4W HEADS INTEGRAL WITHUNIT AND CAPACITY TO ADD A SINGLE REMOTE
HEAD.
X2/EM
Y/EM/FT Y/EM/FT LIGHT ALARMS CAM-SD-OW-FT-H 18 N/A LED INCLUDEDEXTERIOR RATED LED EMERGENCY FIXTURE, OFFWHITE FINISH, FORWARD THROW, NORMALLY OFF,ON DURING POWER FAILURE, INTEGRAL BATTERY
Y/EM Y/EM LIGHT ALARMS CAM-SD-OW-H 18 N/A LED INCLUDEDEXTERIOR RATED LED EMERGENCY FIXTURE, OFF
WHITE FINISH, NORMALLY OFF, ON DURING POWERFAILURE, INTEGRAL BATTERY
PD4
PD4 ET2 CONTEMPORARY LTG E22278-75PC 8 8 INTEGRAL WITH FIXTURE PENDANTDECORATIVE 8 LIGHT PENDANT GYP OR ACT
F LITHONIA MNSL M6 24 N/A LED INCLUDED SURFACE STRIP, 24W MAX, 15W MIN, 4000KF
SURFACE -
D45D45 CONTECH RA6LNC635K12D2/CST6322L2-CLR 44.3 N/A INTEGRAL LED, 2708 LUMENS
RECESSED LED DOWNLIGHT, CLEAR SPECULARREFLECTOR, 3500K, 45W NOMINAL, 44.3 W LISTED,
0-10V DIMMING/NON-DIMMINGRECESSED ACT
TL2TL2
JUNO MONOPOINT TRAC-MASTER T40F-WH
JUNO LAMP HEAD MONOPOINTT690WH 18 1 GIMBAL STYLE LAMP-HOLDER, WHITEGE LED18D38W3930/25; 18W; 92 CRI;3000K; PAR38, MED BASE
FLUSH MONOPOINT FITTING- - FLUSH MONOPOINT FITTING, WHITE
DATA INTERCONNECTION RISER
SCALE: NONE
A
TO MACY'S DATA ROOM
TO BACKWRAP
TO MACY'S POS ROOMTO MACY'S PHONE ROOM
TO MACY'S PHONE ROOM
TO MACY'S PHONE ROOM
CASH DESK ON SALES FLOOR
CABINET IN OPTICAL STATION
LABEL
0401
0502
0603
LABEL
LABEL LABEL
LABEL LABEL
LABEL
1411
1512
1613
LABEL
LABEL LABEL
LABEL LABEL
LABEL
2421
2522
2623
LABEL
LABEL LABEL
LABEL LABEL
INSTALL OUTLETS AT 24" AFFTO CENTERLINE.
CENTER OUTLETS BEHIND CABINET, LINEUP WITHIN AN 15" HORIZONTAL SPACE,BEHIND CABINET ACCESS OPENING
LENSCRAFTERS' NETWORK
NOTE:ALL COMMUNICATIONSWIRING AND JACKS ARESUPPLIED AND INSTALLEDBY OWNER'S VENDOR. GCTO PROVIDE RACEWAYSYSTEM ONLY.
MINISERVERNEEDS TOGO INTOTHISCABINET.
OPTOS
(1) CAT6 (BY OTHERS) BETWEEN JACKS
SECONDEXAM/REFRACTIONROOM
REFRACTION/EXAM ROOM.
LABEL
4441
4542
4643
LABEL
LABEL LABEL
LABEL LABEL
DOCTOR'S RECEPTION DESK
TO MACY'S PHONE ROOM
TO MACY'S PHONE ROOM
TO MACY'S POS ROOMTO MACY'S POS ROOM
LABEL
5451
5552
5653
LABEL
LABEL LABEL
LABEL LABEL
OPTOMETRIST NETWORK - TWO DOOR STATE
LABEL
6461
6562
6663
LABEL
LABEL LABEL
LABEL LABEL
LABEL
7471
7572
7673
LABEL
LABEL LABEL
LABEL LABEL
LABEL
8481
8582
8683
LABEL
LABEL LABEL
LABEL LABEL
LABEL
3431
3532
3633
LABEL
LABEL LABEL
LABEL LABEL
BELOW COUNTER INOPTICAL WORK STATION
TO MACY'S DATA ROOMTO CASH DESKTO CASH DESKOD PHONE
DOCTOR'S PHONE (SPLIT PAIR)
TO BOH CABINETTO BOH CABINETTO MACY'S POS ROOMTO MACY'S PHONE ROOMTO MACY'S PHONE ROOMTO MACY'S PHONE ROOM
DATA LABELING SCHEME - TWO DOOR STATELABELINFO
DESCRIPTION
010203040506
111213141516
212223242526
313233343536
TO BACKWRAP DIGITAL SIGN
DOCTOR'S PHONE (SPLIT PAIR)UNUSEDUNUSEDUNUSEDUNUSEDUNUSED
UNUSEDUNUSEDUNUSEDUNUSEDUNUSEDUNUSED
414243444546
515253545556
616263646566
DATA SERVICEVOICE SERVICE (SPLIT PAIR)VOICE SERVICE (SPLIT PAIR)DATA SERVICEVOICE SERVICEUNUSED
UNUSEDUNUSEDUNUSEDDOCTOR'S PHONEVOICE TO REFRACTIONDATA TO REFRACTION
UNUSEDDATA LINE TO OPTOSVOICE LINE TO OPTOSVOICE SERVICEUNUSEDUNUSED
717273747577
DATA LINE TO OPTOSUNUSEDUNUSEDVOICE LINE TO OPTOSUNUSEDUNUSED
818283848588
UNUSEDUNUSEDUNUSED2ND REFRACTION/EXAM ROOM WHERE USEDUNUSEDUNUSED
LABELINFO
DESCRIPTION LABELINFO
DESCRIPTION
EXISTING TRANSFORMER,150 KVA, 480V - 120/208 Y, 3P, 4W
PANEL7LB
PANEL7LC
PANEL7POS
PANEL7LA
PANEL7L
WATER SUPPLY AND FIRE PROTECTION PLAN
SCALE: 1/4" = 1'-0"
2
PLAN NORTH
SANITARY AND VENT PLAN
SCALE: 1/4" = 1'-0"
1
PLAN NORTH
1. EXTEND NEW SANITARY PIPE TO LOCATION INDICATED ON MPE-100 AND MAKE CONNECTION TO EXISTINGSANITARY PIPE.
2. CONNECT NEW VENT TO EXISTING VENT MAIN IN LOCATION INDICATED ON MPE-100.
3. ALL PLUMBING PIPING TO BE CONCEALED.
4. THE CEILING IN THIS AREA IS A PLENUM. USE CODE MINIMUM PIPING TO CONNECT TO THE BUILDINGSERVICES.
5. EXISTING PIPING IN VOID SPACE TO REMAIN.
SANITARY & VENT ISOMETRIC
SCALE: NONE
A
SUPPLY ISOMETRIC
SCALE: NONE
B
1. CONNECT TO EXISTING DOMESTIC WATER PIPE. G.C. TO COORDINATE WORK WITH LANDLORD FORWATER TIE IN. SEE MPE-100
2. REFER TO DETAIL IN DESIGN MANUAL FOR WATER HEATER PIPING DETAIL.
3. CONTRACTOR SHALL RUN ALL PLUMBING PIPING CONCEALED.
4. EXISTING SPRINKLER HEAD TO REMAIN.
5. REMOVE EXISTING SPRINKLER HEAD. ALL WORK IS TO BE COMPLETED BY THE LANDLORD'S SPRINKLERCONTRACTOR AT THE GC'S EXPENSE. SPRINKLER CONTRACTOR TO INCLUDE ALL WORK, INCLUDING BUTNOT LIMITED TO, LANDLORD COORDINATION, SUBMITTALS AND CALCULATIONS, DRAIN DOWNS, ETC., ASREQUIRED TO COMPLETE THE SPRINKLER SYSTEM REVISIONS TO SUPPORT THE NEW LENSCRAFTERS.
6. PROVIDE NEW SPRINKLER HEADS IN NEW ROOMS. ACTUAL LOCATIONS TO BE DETERMINED BY FIREPROTECTION CONTRACTOR. ALL WORK IS TO BE COMPLETED BY THE LANDLORD'S SPRINKLERCONTRACTOR AT THE GC'S EXPENSE. SPRINKLER CONTRACTOR TO INCLUDE ALL WORK, INCLUDING BUTNOT LIMITED TO, LANDLORD COORDINATION, SUBMITTALS AND CALCULATIONS, DRAIN DOWNS, ETC., ASREQUIRED TO COMPLETE THE SPRINKLER SYSTEM REVISIONS TO SUPPORT THE NEW LENSCRAFTERS.
7. EXISTING SPRINKLER SYSTEM VALVE TO REMAIN. VALVE TO REMAIN ACCESSIBLE.
8. EXISTING PIPING IN VOID SPACE TO REMAIN.
3/4"
NEW ISOLATIONVALVE
1
WH
SK3 SK7
NOTE: (SK1 THRU 7) CONTRACTOR WILL BE REQUIRED TO FURNISH ALL LABOR, PIPING MATERIALS AND APPURTENANCESNECESSARY TO COMPLETE INSTALLATION OF SINKS, FAUCETS AND DRAINS FURNISHED BY OWNER.
SINK
ELECTRIC WATER HEATER
2"
-
1/2"
1/2"
1/2"
1/2"
1-1/2"
-
FIXTURE DRAIN HOT COLD VENT
PLUMBING FIXTURE QTY. SAN F.U. EACH SAN F.U. TOTAL C.W F.U. EACH WTR. DMD.TOTAL
SINK (SK3 & SK7)
TOTALS
SERVICE CONNECTION SIZE
2 2.0 4.0 2.0 4.0
4.0 4.2
SAN. WATER2" 3/4"
STANDARD P.D.I. WH 201 WATER HAMMER ARRESTERSCHEDULE
P.D.I. UNITS
FIXTURE UNITS 1-3 4-11 12-32 33-60 61-113 114-154 155-330
XX
CAP ON END LINE
WALL CLEANOUT
M
TEE OUTLET DOWN
TEE OUTLET UP
ELBOW UP
ELBOW DOWN
POINT OF NEW CONNECTIONTO EXISTING PIPING OR SYSTEM
SANITARY PIPING (W)
HOT WATER (HW)
COLD WATER (CW)
SANITARY VENT PIPING (V)
DOWN
OVERHEAD
UNDERGROUND
EXISTING
O/H
DN
U/G
EX
WATER METER
WC
SK5 PLUMBING FIXTURES
(ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED ON THE DRAWINGS)
VALVE
KEY NOTES - SUPPLY PLAN
5-LCM-P200-REV 0.0
5 KEY NOTES - SANITARY/VENT PLAN
6
6-LCM-P200-REV 0.0
1 PLUMBING SYMBOLS
PLUMBING CALCULATIONS
PLUMBING FIXTURE - CONNECTION SCHEDULE
2
3
4
1-LCM-P200-REV 0.0
2-LCM-P200-REV 0.0
3-LCM-P200-REV 0.0
4-LCM-P200-REV 0.0
MARK
PLUMBING EQUIPMENT SCHEDULE
DESCRIPTIONSUPPLIED/INSTALLED BY
MODEL # /COLOR REMARKS
GENERAL NOTE: FOLLOW ALL MANUFACTURERS INSTALLATION ANDMAINTENANCE INSTRUCTIONS.
SK-3
SK-7 T / PC30" SINK FOR BOH-SU30 ELKAY SINK: LLVR2117,STRAINER: 1135,FAUCET: DELTA 101DST0.5 GPM
*SELECT 1-HOLE DRILLING CONFIGURATION. G.C. TO MAKE FINALCONNECTIONS. INSTALL MIXING VALVE BELOW FIXTURE, CONNECT TOSUPPLY PIPING AT FIXTURE, SET WATER TEMP. @ 110° F IF REQUIRED.
T / PC GC TO MAKE FINAL CONNECTIONS. INSTALL MIXING VALVE BELOWFIXTURE, CONNECT TO SUPPLY PIPING AT FIXTURE, SET WATER TEMP. @110° F.
TANKLESS WATERHEATER MOUNTEDBELOW SINKS INCABINET.
IWH-1AIWH-1B
EEMAX MODEL #SP2412PC / PCSINGLE POINT, 120 VOLT, 1 PHASE, 60 HZ, 2.4 KW, 33° TEMPERATURE RISE.
JUST SINKS(847)678-5150
MFG./PHONE #
ROUND SINK FORCONTACT LENS
SINK: CLF-ADA-10FAUCET: JUST # J-9810.5 GPM
3 4
3 4
(TYP)
(TYP)
3 4(TYP)
STORE #8871
NORTH EAST MALL
1101 MELBOURNE RD. SUITE 3000
HURST, TEXAS 76053
1
5/17/2017 OWNERS COMMENTS
Seal
ByDateMark
Revisions:
a
ap
p
4000 Luxottica Place, Mason, OH 45040
6 Creamery Brook, East Granby, CT 06026
+1 (513) 765-6000
+1 (516) 393-2484
SheetDate
Drawn By
Checked By
Title
ISSUED FOR:
Nextore project
Number
Client Review
DOB Permit
DOB Permit - Re-Submit
Bid
Construction
LL Approval
Brand Design Type:
Construction for:
Nextore Store Design Revision No.:
DESIGN & CONSTRUCTION
MANAGEMENT:
74149
DESIGN REV 01
MODULAR
11/9/2017
STAFF
SRH
4000 Luxo
ttica Place M
aso
n, O
hio
45040
A Sub
sid
iary o
f the Luxo
ttica G
ro
up
Architect / Engineer Job No.:
LCM 012
Engineer of Record
2
11/10/2017 OWNERS COMMENTS
SANITARY AND
VENT PLANS AND
DETAILS
P200
HOT WATER SUPPLY TOSINKTANKLESS WATERHEATER (SEESCHEDULE)
SHUT OFF VALVE
WATER SUPPLY
COLD WATER SUPPLY TOSINK
DRAIN FROM SINK
SINK AND FAUCET(SEE SCHEDULE)
WATER HEATER PIPING SCHEMATIC
SCALE: NONE
C
44
4
4
44
4
6
6
6
6
SK3
IWH-1B2
SK7 IWH-1A2
3(TYP)
3(TYP)
3(TYP)
1/2"
1/2"
1
3/4"
5
5
5
5
55
5
SK3
SK3
21
2
3 SK3
IWH-1B
1/2"
2SK7
1/2"
IWH-1A
3
SK-7
1 1/2"
2"
1 1/2"
SK33
3
1
2
2"
2"
1 1/2"
78
8
5
5
CLG. HT.=
PRETEST
102
10'-0"
CLG. HT.=
CONTACT LENS /
OPTICAL STATION
104
10'-0"
CLG. HT.=
RETAIL SALES AREA
100
10'-6 1/2"
CLG. HT.=
OD RECEPTION
/ WAITING
103
8'-0"
CLG. HT.=
REFRACTION
ROOM
101
10'-0"
CLG. HT.=
PRETEST
102
10'-0"
CLG. HT.=
CONTACT LENS /
OPTICAL STATION
104
10'-0"
CLG. HT.=
RETAIL SALES AREA
100
10'-6 1/2"
CLG. HT.=
OD RECEPTION
/ WAITING
103
8'-0"
CLG. HT.=
REFRACTION
ROOM
101
10'-0"
3/4"
3/4"
6