legacy system prosthetic catalog 2012_int
DESCRIPTION
Legacy System Prosthetic Catalog 2012 (International)TRANSCRIPT
Legacy2
LegacyLegacy™ Prosthetic™ ProstheticCatalogCatalog
1
Legacy Labeling: Definitions & Descriptions
1) Our products carry the CE mark and fulfill the requirementsof the Medical Device Directive 93/42/EEC
2) Manufacturer Symbol3) Product code or reference number4) Product description5) Use before expiration date (XXXX-XX)6) Gamma sterilization symbol7) Single-use only symbol8) Caution: US law restricts the sale of these devices
by or on the order of a dentist or physician9) Tamper proof symbol
10) Refer to Instructions For Use (IFU)11) Lot number (XXXXXXXXXX)12) Implant body diameter color reference on surgical tray13) Implant prosthetic platform diameter (written and color-coded)14) Non-sterile symbol
3.5
8035-478035-47
Platform: 3.5mm Diam Pla
stic Tem
porar
y Ab
ut. #
8035
-47
xxxxxxxxxxxx
xxxxxxxxxxxx
mmPla
tform
Plastic Tem
porar
y Ab
ut.# 8
035-47
3.5 m
m Pla
tform
Plastic Engaging Temporary AbutmentIncludes: Fixation Screw [1000-01]
Legacy Prosthetic Vial and Cap Label
3
1
4
7
8
14 11
13
13
109
80 = Legacy prosthetics35 = 3.5mmD platform diameter-47= prosthetic specific code
2
2
The implant is mounted on a color-coded Carrier/Transfer. A cover screw and extender are included in each vial.
Each cap label is color coded byplatform diameter of implant
All the implants come in a sterile vial
Each vial label is color-coded with two tear-off labels
Drop implant assembly out of vial onto a sterile surface
Remove implant assembly withinsertion tool & drill or ratchet
Remove the holder containingthe cover screw & extender
Align the flat of the fixture mount to the labial
Unscrew the cover screw & extender
Prepare surgical site withdouble cutting step drill
Insert implant into osteotomy Index fixture-mount flat to labial
Remove fixture-mount
Attach the cover screw to implant
Suture soft tissue over coverscrew
Attach the cover screw & extender to implant
Suture soft tissue aroundcover screw & extender
Legacy Fixture-Mount Packaging
To establish the optimum angle of the abutment, indexthe flat surface of the Fixture Mount/Transfer eithertoward or away from the desired direction of abutmentangle at the time of implant placement.
Fig. 3 The two-piece, 15º AngledAbutment consists of an angled
body and a fixation screw
Orienting the 15º Angled AbutmentThe flat side of the transfer [Fig. 1] or Hexagon Tool [Fig. 2] andthe angle of the 15° abutment [Fig. 3] are manufactured toalign with the flat of the implant’s internal hexagon.
Fig. 1Fixture Mount/Transfer
Fig. 22.5mmD Hex Tool
3
During implantplacement, indexthe flat of theFixture-Mount
Pour the working cast in dental stonewith soft tissuereplication material
Option 2 : Stage-One transfer followed by laboratory procedures for abutment preparation and provisionalization
Attach the AngledAbutment to theImplant Analog in theworking cast with a1.25mmD Hex Tool
With Fixture-Mountin place, make aconventional transfer impression
Attach the CoverScrew & submergeimplant
The Fixture-Mount isretained within theimpression materialwhen it is removed
Modify angle ofabutment &refine margins as required
Fabricate the temporary crown
Occlude screwaccess hole &confirm contour of restoration
Cement theprovisionalrestoration
At Stage-Two Surgery,attach the preparedabutment, tighten to 30 Ncm with a TorqueWrench
Option 1 : Attaching an Angled Abutment and chairside procedures for preparation
Common procedures for abutment placement, margin finessing, impressing and placement of restoration
Remove theHealingCollar with a1.25mmDHex Tool
Attach provisionalrestoration & cementonto thepreparedabutment
Attach the abutmentwith the1.25mmDHex Tool
Tighten to 30 Ncm witha TorqueWrench
Make animpressionfollowingstandardclinicalprocedures
Mark therequiredmodificationsto achieveappropriateclearance
Finesse themargins witha high-speedbur &copious irrigationprior to finalimpressing
Attach theabutment to the correspondingImplant Analog& reduce theabutmentto achieveappropriateclearance
Followingstandard laboratoryprocedures,fabricate the finalrestoration &cement ontothe preparedabutment
Detach the abutmentwith the1.25mmDHex Tool
Clinical & Laboratory Procedures for Contoured Abutments
Remove theimpression fromthe working castexposing top ofImplant Analog
4
7. Seat denture over Titanium TemporaryAbutment to confirm passive placement. Checkocclusion with opposing arch. Occlude screwaccess hole with cotton pellet.
1. Unthread the healing collars from the implantusing 1.25mmD Hex Tool. The top of the implantsare exposed.
10. Optional step: Attach implant analogs to baseof denture. Pour a soft tissue working cast toprevent engagement with undercuts. Articulatewith opposing arch.
6. Use acrylic trimmer to drill holes throughdenture corresponding to marked positions.
3. Place the fixation screw through theabutment and tighten in place using theappropriate 1.25mmD Hex Tool. The torquevalue of the fixation screw is determined byclinician. Standard torque value for fixationscrews is 30Ncm.
12. Attach prosthesis to implants & tighten inplace using the appropriate tooling. Occludescrew access holes with material of choice.
2. Use the prepared implant fixture mount as a temporary abutment (reshaping of hex atapex is essential) or select the TitaniumTemporary Abutment matching the implantprosthetic platform.
11. Remove denture & trim the prosthesis toallow access for patient cleaning. The prosthesisis now a fixed restoration, removable by clinicianonly.
5. Mark position of Titanium TemporaryAbutments on under surface of denture withindelible marker.
4. Confirm there is less than 40 degrees ofrelative divergence between abutments to besplinted together.
8. Use autopolymerizing acrylic or similar lightcure material to attach prosthesis to TitaniumTemporary Abutments. Allow to set prior toremoval from mouth.
9. Remove prosthesis from the mouth, flipover to expose tissue side. Use additionalautopolymerizing resin to fill in any voidsaround the processed abutments.
Clinical Procedures for Titanium Temporary Abutment/Fixture-Mount
8035-318035-32
8035-31C8035-32C
8035-518035-52
3.5mmD Platform3.0mmD Platform
8530-01 8530-13 8530-15
85378530-21 8530-22 8530-23
3037-26
8537-028035-21 8035-22 8035-23
8035-40 8035-41 8035-44
8035-64-15 8035-64-30
8035-94-15 8035-94-30
8530-62 8530-648530-61
8035-72
8530-318530-32
8530-518530-52
8530-31C8530-32C
8530-51-15C8530-52-15C
8530-51-08C8530-52-08C
8530-41 8530-468530-40 8530-47 8530-49
8035-91
8530-05 8530-08 8530-06 8035-01 8035-13 8035-15
Fixture-Mount
8530-91 8530-93 8530-948530-92
Cover Screws, Healing Collars,Implant Transfers & Analogs
Straight Abutments, Comfort Caps, Transfers & Analogs
Engaging & Non-EngagingAbutments
Ball, GPS™ & Screw-Receiving
Overdenture Abutments
Straight & AngledContoured & HLA Abutments
Legacy Selection Chart
5
4.5mmD Platform 5.7mmD Platform
Fixture-Mount
3047
3047-26
3047-02
30578045-21 8045-22 8045-23
3057-26
3057-02 3065-02
30658057-21 8057-22 8057-23
3065-26
8057-318057-32
8057-518057-52
HLA5-6HLA5-7
8045-318045-32
8045-31C8045-32C
8045-518045-52
8045-51-08C8045-52-08C
8045-51-15C8045-52-15C
HLA4-5HLA4-6
8035-51-08C8035-52-08C
8035-51-15C8035-52-15C
HLA3-4HLA3-5
8035-46 8035-47 8035-49 8045-40 8045-41 8045-44 8045-46 8045-47 8045-49 8057-40 8057-44 8057-46 8057-47 8057-49
8035-62 8035-64
8035-74
8035-94 8035-95
8045-61 8045-62 8045-64
8045-72 8045-74
8045-91 8045-93 8045-948045-92
8045-64-15 8045-64-30
8045-95
8057-61 8057-62 8057-64
8057-72 8057-74
8057-91 8057-93 8057-948057-92 8057-95
8035-05 8035-08 8035-06 8045-01 8045-13 8045-15 8045-05 8045-08 8045-06 8057-01 8057-13 8057-15 8057-05 8057-08 8057-06
Fixture-MountFixture-Mount
8035-61
8045-94-15 8045-94-308035-92 8035-93
6
7
Code Description1000-20 For use with 3.0mmD hexagon platform1000-41 For use with 3.0mmD hexagon platform1000-26 For use with 3.0mmD hexagon platform1000-01 For use with 3.5, 4.5 & 5.7mmD hexagon platforms1000-06 For use with 3.5, 4.5 & 5.7mmD hexagon platforms1000-10 For use with 3.5, 4.5 & 5.7mmD hexagon platforms
Code Platform Width Length8530-13 3.0mmD 3.8mmD 3mmL8530-15 3.0mmD 3.8mmD 5mmL8035-13 3.5mmD 4.8mmD 3mmL8035-15 3.5mmD 4.8mmD 5mmL8045-13 4.5mmD 5.8mmD 3mmL8045-15 4.5mmD 5.8mmD 5mmL8057-13 5.7mmD 6.6mmD 3mmL8057-15 5.7mmD 6.6mmD 5mmL
Healing Collars
Closed-Tray Implant Transfers
Open-Tray Implant Transfers
Cover Screws, Healing Collars, Transfers & Analogs
Code Platform Replacement Screw8530-05 3.0mmD 1000-418035-05 3.5mmD 1000-068045-05 4.5mmD 1000-068057-05 5.7mmD 1000-06
Implant Analogs
Code Platform8530-06 3.0mmD8035-06 3.5mmD8045-06 4.5mmD8057-06 5.7mmD 8057-068045-068530-06 8035-06
Surgical Cover Screws
Code Code [*for 6mmL Only] Platform8530-01 - 3.0mmD8035-01 8035-01S 3.5mmD8045-01 8045-01S 4.5mmD8057-01 8057-01S 5.7mmD
8530-13 8035-13 8045-13 8057-13
Price includes Fixation Screw with 1.25mmD Hex
Requires 1.25mmD Hex Tool
1000-061000-41 8035-05 8045-05 8057-05
Price includes Fixation Screw with 1.25mmD Hex
Code Platform Replacement Screw8530-08 3.0mmD 1000-268035-08 3.5mmD 1000-108045-08 4.5mmD 1000-108057-08 5.7mmD 1000-10
1000-10 8035-08 8045-08 8057-088530-081000-26
8530-05
Replacement Fixation Screws
1000-26
Open-Tray Transfer& Waxing Screw
1000-203.0mmD Hex Platform
1000-061000-01 1000-101000-41
Closed-TrayTransfer &TemporaryAbutment
8530-15 8035-15 8045-15 8057-15
8035-01*8035-01S
8530-01 8057-01*8057-01S
8045-01*8045-01S
Abutments
Requires 1.25mmD Hex Tool
Requires 1.25mmD Hex Tool
Straight Abutment Analogs
Straight Abutment Castable Coping
Straight Abutment Comfort Caps
Straight Abutment Transfers
Straight Abutments
Code Platform Collar Heights Use Analog8530-21 3.0mmD 1.0mm 85378530-22 3.0mmD 2.0mm 85378530-23 3.0mmD 3.0mm 85378035-21 3.5mmD 1.0mm 30478035-22 3.5mmD 2.0mm 30478035-23 3.5mmD 3.0mm 30478045-21 4.5mmD 1.0mm 30578045-22 4.5mmD 2.0mm 30578045-23 4.5mmD 3.0mm 30578057-21 5.7mmD 1.0mm 30658057-22 5.7mmD 2.0mm 30658057-23 5.7mmD 3.0mm 3065
8
Straight Abutments, Snap-on Transfers & Lab Analogs
Includes Transfer, Comfort Cap & Fixation Screw with 1.25mmD Hex
Code Abutment Width3037-26 3.7mmD3047-26 4.7mmD3057-26 5.7mmD3065-26 6.5mmD
Code Abutment Width8537-02 3.7mmD3047-02 4.7mmD3057-02 5.7mmD3065-02 6.5mmD
3047-26 3057-26 3065-263037-26
3047-02 3057-02 3065-028537-02
3047 3057 30658537
Code Abutment Width3037-28 3.7mmD3047-28 4.7mmD3057-28 5.7mmD3065-28 6.5mmD
3047-28 3057-28 3065-283037-28
Includes Castable Coping
8530-23 8035-23 8045-23 8057-23
8530-22 8035-22 8045-22 8057-22
8530-21 8035-21 8045-21 8057-21
Code Abutment Width8537 3.7mmD3047 4.7mmD3057 5.7mmD3065 6.5mmD
Code Platform Angulation Collar Heights Replacement Screw8045-31C 4.5mmD 0° 1mm 1000-018045-32C 4.5mmD 0° 2mm 1000-01
8045-51-08C 4.5mmD 8° 1mm 1000-018045-52-08C 4.5mmD 8° 2mm 1000-018045-51-15C 4.5mmD 15° 1mm 1000-018045-52-15C 4.5mmD 15° 2mm 1000-018045-30CB 4.5mmD - .5mm 1000-01
Code Platform Angulation Collar Heights Replacement Screw8530-31C 3.0mmD 0° 1mm 1000-208530-32C 3.0mmD 0° 2mm 1000-20
8530-51-08C 3.0mmD 8° 1mm 1000-208530-52-08C 3.0mmD 8° 2mm 1000-208530-51-15C 3.0mmD 15° 1mm 1000-208530-52-15C 3.0mmD 15° 2mm 1000-208530-30CB 3.0mmD - .5mm 1000-20
Code Platform Angulation Collar Heights Replacement Screw8035-31C 3.5mmD 0° 1mm 1000-018035-32C 3.5mmD 0° 2mm 1000-01
8035-51-08C 3.5mmD 8° 1mm 1000-018035-52-08C 3.5mmD 8° 2mm 1000-018035-51-15C 3.5mmD 15° 1mm 1000-018035-52-15C 3.5mmD 15° 2mm 1000-018035-30CB 3.5mmD - .5mm 1000-01
Price includes Fixation Screw with 1.25mmD Hex
Code Platform Collar Heights Replacement Screw8530-31 3.0mmD 1mm 1000-208530-32 3.0mmD 2mm 1000-208035-31 3.5mmD 1mm 1000-018035-32 3.5mmD 2mm 1000-018045-31 4.5mmD 1mm 1000-018045-32 4.5mmD 2mm 1000-018057-31 5.7mmD 1mm 1000-018057-32 5.7mmD 2mm 1000-01
Straight Titanium Contoured Abutments
9
Straight & Angled Contoured, Titanium & Zirconia Abutments
8035-31 8045-31 8057-318530-31
8035-32 8045-32 8057-328530-32
Price includes Fixation Screw with 1.25mmD Hex
Code Platform Collar Heights Replacement Screw8530-51 3.0mmD .75mm 1000-208530-52 3.0mmD 2mm 1000-208035-51 3.5mmD .75mm 1000-018035-52 3.5mmD 2mm 1000-018045-51 4.5mmD .75mm 1000-018045-52 4.5mmD 2mm 1000-018057-51 5.7mmD .75mm 1000-018057-52 5.7mmD 2mm 1000-01
Angled Titanium Contoured Abutments
8035-51 8045-51 8057-518530-51
8035-52 8045-52 8057-528530-52
Price includes Fixation Screw with 1.25mmD Hex0°, 8° & 15° Zirconia Contoured Abutments
8530-52-08C 8530-52-15C8530-32C
8035-51-15C8035-31C
8045-51-08C 8045-51-15C8045-31C
8045-52-08C 8045-52-15C
8530-30CB
8035-30CB
8045-30CB
8530-31C 8530-51-08C 8530-51-15C
8035-32C 8035-52-08C 8035-52-15C
8045-32C
8035-51-08C
Code Platform Collar Heights Replacement ScrewHLA3-4 3.5mmD 0mm 1000-01HLA3-5 3.5mmD 0mm 1000-01HLA4-5 4.5mmD 0mm 1000-01HLA4-6 4.5mmD 0mm 1000-01HLA5-6 5.7mmD 0mm 1000-01HLA5-7 5.7mmD 0mm 1000-01
Price includes Fixation Screw with 1.25mmD Hex Straight Full-Contoured (HLA) Abutments
HLA3-5 HLA4-6
HLA3-4 HLA4-5
HLA5-7
HLA5-6
Engaging & Non-Engaging, Gold, Plastic & Titanium Abutments
Price includes Fixation Screw with 1.25mmD Hex
Code Platform Collar Heights Replacement Screw8530-40 3.0mmD 1.0mm 1000-208035-40 3.5mmD 1.0mm 1000-018045-40 4.5mmD 1.0mm 1000-018057-40 5.7mmD 1.0mm 1000-01
Gold Engaging Cast-to Abutments
8530-40 8035-40 8045-40 8057-40
Price includes Fixation Screw with 1.25mmD Hex
Code Platform Collar Heights Replacement Screw8530-46 3.0mmD 0mm 1000-208035-46 3.5mmD 0mm 1000-018045-46 4.5mmD 0mm 1000-018057-46 5.7mmD 0mm 1000-01
Plastic Non-Engaging Castable Abutments
8530-46 8035-46 8045-46 8057-46
Price includes Fixation Screw with 1.25mmD Hex
Code Platform Collar Heights Replacement Screw8530-49 3.0mmD 1.0mm 1000-208035-49 3.5mmD 1.0mm 1000-018045-49 4.5mmD 1.0mm 1000-018057-49 5.7mmD 1.0mm 1000-01
Titanium Non-Engaging Temporary Abutments
8530-49 8035-49 8045-49 8057-49
Price includes Fixation Screw with 1.25mmD Hex
Code Platform Collar Heights Replacement Screw8530-47 3.0mmD 1.0mm 1000-418035-47 3.5mmD 1.0mm 1000-068045-47 4.5mmD 1.0mm 1000-068057-47 5.7mmD 1.0mm 1000-06
Plastic Engaging Temporary Abutments
8530-47 8035-47 8045-47 8057-47
Price includes Fixation Screw with 1.25mmD Hex
Code Platform Collar Heights Replacement Screw8035-44 3.5mmD 0mm 1000-018045-44 4.5mmD 0mm 1000-018057-44 5.7mmD 0mm 1000-01
Plastic Engaging Castable Abutments
8035-44 8045-44 8057-44
Price includes Fixation Screw with 1.25mmD Hex
Code Platform Collar Heights Replacement Screw8530-41 3.0mmD 1.0mm 1000-208035-41 3.5mmD 1.0mm 1000-018045-41 4.5mmD 1.0mm 1000-01
Gold Non-Engaging Cast-to Abutments
8530-41 8035-41 8045-41
10
11
3.0mmDPlatform
3.5mmDPlatform
4.5mmDPlatform
5.7mmDPlatform
Selection Chart: Overdenture & Screw-Retained Restorations
BallAbutment
Components
Ball Abutments
OverdentureAbutments
Overdenture Screw-Retained Copings
OverdentureAbutment
Components
OD AbutmentComfort Cap
Transfer &Analogs
*1000-68*4000-13
Open-Tray Transfer Closed-Tray Transfer
Screw-Receiving Overdenture Abutment Transfer, Analog & Comfort Cap
GPSAbutment
Components
GPSAbutments
Gold Titanium Plastic Gold/Plastic Titanium
1000-61 1000-62 1000-63
1000-64 1000-65 1000-66 1000-67 1000-69
Abutments are compatible with Zimmer, BioHorizons (internal) and MIS Implants with 3.5mm, 4.5mmD and 5.7mmD prosthetic platforms
8530-618530-628530-64
8057-618057-628057-64
8035-618035-628035-64
Screw-Receiving Overdenture Abutments (*Includes Transfer & Comfort Cap)
8045-618045-628045-64
8045-64-158045-64-30
8035-64-158035-64-30
8035-728035-74
8045-728045-74
8057-728057-74
**1000-84**1000-87 1000-85 1000-81 1000-82 1000-88 1000-83 1000-86
8035-918035-928035-938035-948035-95
8530-918530-928530-938530-94
8045-918045-928045-938045-948045-95
8057-918057-928057-938057-948057-95
GPS Attachments
Ball Attachments
Ball Abutments (**Includes Transfer & Comfort Cap)
***1000-94 1000-95 1000-98S 1000-96***4500-26
***1000-91
1000-98SI
1000-92C 1000-92E
1000-93
1000-92R1000-92G
1000-92B1000-92P 1000-92W
8035-94-158035-94-30
8045-94-158045-9 4-30
GPS Abutments (***Includes Transfer, Abutment Housing Kit & Comfort Cap)
Platform Collar Heights2mmL 4mmL
3.5mmD 8035-72 8035-744.5mmD 8045-72 8045-745.7mmD 8057-72 8057-74
Code Platform Description8035-64-15 3.5mmD 15º Angled Abutment8045-64-15 4.5mmD 15º Angled Abutment8035-64-30 3.5mmD 30º Angled Abutment8045-64-30 4.5mmD 30º Angled Abutment
Screw-Receiving Angled Overdenture Abutments Includes Transfer & Comfort Cap - requires1.25mmD & 2.5mmD Hex Tool
12
8045-64-30
Screw-Receiving, Ball & GPS Abutments
Includes Transfer & Comfort Cap -requires 1.25mmD Hex Tool
8057-728057-74
8035-728035-74
8045-728045-74
Ball Abutments
Platform Collar Heights1mmL 2mmL 4mmL
3.0mmD - 8530-62 8530-643.5mmD 8035-61 8035-62 8035-644.5mmD 8045-61 8045-62 8045-645.7mmD 8057-61 8057-62 8057-64
Includes Transfer & Comfort Cap -requires 1.25mmD Hex Tool
Screw-Receiving Overdenture Abutments
8035-61 8035-62 8035-64
8045-618045-628045-64
8057-618057-628057-64
8530-628530-64
8035-64-308035-64-15 8045-64-15
Code Platform Description8035-94-15 3.5mmD 15º Angled Abutment8045-94-15 4.5mmD 15º Angled Abutment8035-94-30 3.5mmD 30º Angled Abutment8045-94-30 4.5mmD 30º Angled Abutment
Screw-Receiving Angled GPS Abutments Includes Transfer, Comfort Cap, Metal Housing, WhiteMale Liner & Spacer - requires 1.25mmD Hex Tool
8045-94-308035-94-308035-94-15 8045-94-15
GPS Abutments
Platform Collar Heights1mmL 2mmL 3mmL 4mmL 5mmL
3.0mmD 8530-91 8530-92 8530-93 8530-94 -3.5mmD 8035-91 8035-92 8035-93 8035-94 8035-954.5mmD 8045-91 8045-92 8045-93 8045-94 8045-955.7mmD 8057-91 8057-92 8057-93 8057-94 8057-95
Includes Transfer, Comfort Cap, Metal Housing, White MaleLiner & Spacer - requires 1.25mmD Hex Tool
8530-918530-928530-938530-94
8035-918035-928035-938035-948035-95
8045-918045-928045-938045-948045-95
8057-918057-928057-938057-948057-95
Code Description1000-60 Replacement Screw Top for Angled Base [Requires 2.5mmD Hex Tool]
1000-70 Replacement Ball Top for Angled Base [Requires 1.25mmD Hex Tool]1000-90 Replacement GPS Top for Angled Base [Requires 1.25mmD Hex Tool]
Replacement Tops for Angled Abutments Includes Transfer & Comfort Cap
1000-901000-701000-60
GPS Abutment Transfer, Analogs and Alignment Tools
Code Description1000-94 Impression Coping - 2ea1000-95 Abutment Analog 4mmD - 2ea1000-97 Abutment Parallel Post - 4ea1000-10 Guide Screw for Legacy - 2ea1000-26 Guide Screw for Legacy 3.0mmD Platform - 2ea4500-26 Comfort Cap - 2ea1000-99 Plastic Abutment Angle Measure Guide
Code Prosthetic Platform Description1000-61 5.0mmD Aluminum Analog1000-62 5.0mmD Open-Tray Transfer plus Fixation Screw1000-63 5.0mmD Closed-Tray Transfer plus Fixation Screw1000-68 5.0mmD Plastic Abutment Transfer - 2ea4000-13 5.0mmD Plastic Comfort Cap - 2ea1000-14 - Replacement Open-Tray Fixation Screw - 2ea1000-15 - Replacement Closed-Tray Fixation Screw - 2ea
13
Code Description1000-81 Ball Abutment Housing - 2ea1000-82 Nylon Liner - 2ea1000-83 Nylon Liner Transfer - 2ea1000-84 Ball Abutment Transfer - 2ea1000-85 Ball Abutment Analog1000-86 Ball Abutment Tools1000-87 Ball Abutment Comfort Cap - 2ea1000-88 Ball Abutment Housing & Nylon Liner
Ball Abutment Components
1000-82
1000-84
1000-861000-85 1000-87 1000-88
1000-831000-81
Code Prosthetic Platform Description1000-05 - Coping Replacement Fixation Screw - 2ea1000-64 5.0mmD Gold Coping1000-65 5.0mmD Titanium Coping1000-66 5.0mmD Plastic Coping1000-67 5.0mmD Gold & Plastic Coping1000-69 5.0mmD Titanium Temporary Coping
Overdenture Screw-Retained Abutment Components
1000-661000-65 1000-671000-05 1000-64 1000-69
Screws require 1.25mmD Hex Tool
Screw-Receiving Overdenture Abut. Comfort Cap, Transfers & Analog
1000-681000-61 1000-62 1000-63 4000-13
1000-10 1000-26 1000-99
1000-97
1000-95
1000-94
Code Description1000-96 Core Tool - Male Removal & Seating Tool
GPS Instrumentation
1000-96
Ancillary Components for Overdenture & Screw-Retained Restorations
Includes Fixation Screw [1000-05]with 1.25mmD Hex
4500-26
Code Retention Force Description1000-92W 5.0lbs Internal Replacement Male White - 4ea1000-92P 3.0lbs Internal Replacement Male Pink - 4ea1000-92B 1.5lbs Internal Replacement Male Blue - 4ea1000-92C 4.5lbs External Replacement Male Clear - 4ea1000-92G 3.0lbs External Replacement Male Green - 4ea1000-92E 2.0lbs External Replacement Male Orange - 4ea1000-92R 1.0lb External Replacement Male Red - 4ea1000-91 - GPS Abutment Housing Kit - 1ea1000-93 - Black Processing Male - 4ea1000-98SI Assorted Internal Processing Cap/Male Kit - 1ea1000-98S Assorted External Processing Cap/Male Kit - 1ea
GPS Abutment Components
1000-93
1000-92B
1000-92E
1000-92P
1000-98S
1000-91
1000-92G
1000-92W
1000-98SI
1000-92C
1000-92R
Straight Hex Tools
Code DescriptionHT1.25L 1.25mmD Straight Hex Tool Extra Long (For use with Torque Wrench)HT1.25 1.25mmD Straight Hex Tool Long (For use with Torque Wrench)HT1.25S 1.25mmD Straight Hex Tool Short (For use with Torque Wrench)HT2.0 2.0mmD Hex Tool LongHT2.0S 2.0mmD Hex Tool ShortHT2.5 2.5mmD Hex Tool Long (with retentive O-ring)HT2.5S 2.5mmD Hex Tool Short (with retentive O-ring)HT3.0 3.0mmD Hex Tool LongHT3.0S 3.0mmD Hex Tool Short
Square connection for use with Ratchet or Torque Wrench
Surgical & Prosthetic Instruments
14
Tapered Hex Tools
Code DescriptionTHT1.25 1.25mmD Tapered Hex Tool LongTHT1.25S 1.25mmD Tapered Hex Tool Short
THT1.25STHT1.25
Hex Drills
Code DescriptionHD1.25 1.25mmD Hex DrillHD2.0 2.0mmD Hex DrillHD2.5 2.5mmD Hex Drill (with retentive O-ring)HD3.0 3.0mmD Hex Drill HD1.25 HD3.0HD2.0 HD2.5
Latch head connection for use with Surgical Motor
Ancillary Instruments
Code DescriptionR Ratchet
TW30 30Ncm Torque WrenchTW35 35Ncm Torque WrenchSSH2.5 2.5mmD Stainless Steel Handle (with retentive O-ring)FMD Fixture Mount DrillPAR Paralleling Tool 2.8/2.3
LDRILL Locator DrillDE Drill ExtenderTWM Multi-Setting Torque Wrench (15, 20, 25, 30, 35, 40, 45, 50 & 60Ncm)ABH Analog Holder
R TW30
PARFMD DELDRILL
ABH
TWM
HT3.0HT2.5HT2.0HT1.25
HT2.5S HT3.0SHT2.0SHT1.25S
HT1.25L
TW35 SSH2.5
www.implantdirect.com | 888-649-6425
Legacy™ Implant System Advantages:
Designed For Success,
Legacy1Standard “V” ThreadsMatches Screw-Vent®
Legacy2Spiral Threads
for Increased Stability
Legacy3Buttress Threads
for Increased SurfaceIndustry-Compatible Internal Hex
Three Implant Designs & Packaging Options
Prosthetic compatibility with Zimmer Dental Screw-Vent®, BioHorizons® & MIS implants
Allows for selection based on price, packaging or thread designLegacy1: $125 includes cover screw, healing collar & plastic carrierLegacy2: $150 includes cover screw, healing collar & temporary abutment/transferLegacy3: $175 includes cover screw, healing collar & preparable abutment/transfer
Surgical Compatibility with Tapered Screw-Vent®No need to change surgical protocol or tools
Widest Range of Dimensional OptionsThe entire Legacy system includes seven implant diameters (3.2, 3.7, 4.2, 4.7, 5.2, 5.7, 7.0mm) & six implant lengths (6, 8, 10, 11.5, 13, 16mm)
Packaged For Value
Micro-ThreadsReduce crestal stress for improved initial stability
All-in-1 Packaging includes implant, abutment,transfer, cover screw & healing collar
Legacy™3 Implant
$175 vs $621 from Zimmer Dental1
Reality Check Zimmer Customers
Save $446 with Legacy3
Customer Service &Technical Support
online, over thephone, or in your office Five Year
Warranty2
Cover Screw Healing Collar