Designed for Easy Installation in New and Existing Fixtures, the HyLite LED Arc-Cob Lamp features Excellent Optics for Increased Visibility, and Low Power Consumption, saving up to 90% on Electricity Costs. With a Lamp Life of up to 60,000 hours, the HyLite LED Arc-Cob Lamps Significantly Reduce Relamping costs, thus decreasing Maintenance and Disposal Costs.
The HyLite LED Arc-Cob Lamp enhances vision for better Optical Acuity, and reduces Light Pollution (No Wasted Light). Suitable for Fully Enclosed Fixtures, its Compact Size makes it the ideal Replacement for CFL, MV, HID, and HPS Lamps in Various Applications.
• FullyEncapsulated:Shatterproof,High-Shock&High-VibrationResistant
•InstantStartandRestart:NoWarm-upTimerequired
• Quick&EasyInstallation:NoBallastnecessary.DirectRetrofitinto existingsocketbysimplybypassingtheBallast.
• ExtremelyEfficient:HighLumenEfficacy:113LpWwithHighCRI>80
•350°RotatableBaseforDirectionalLighting
• Heat&ImpactResistant,UVProtected,Non-yellowing,OpticalGradeLens
• SafeandReliable:IsolatedCircuitDesign.NoNoiseorRFInterference
• GoodHeatDissipationwithProprietary-designedHeatSink
• UniversalVoltage:100-277V,AC
• Integral1kVSurgeSuppressor&Protection.IncludesaFree20kAin-line Surge Protection Device for added Protection
• NoUVRadiation–DoesNotAttractInsects
• WideAmbientOperatingTemperature:-40°Fto+131°F[-40°Cto+55°C]
•IdealforusewithRenewableEnergyResources–Solar&WindPower
•Safe:ContainNoHazardousMaterials;RoHSCompliant:NoLead, Mercury,ToxicMetalsorArsenicGases.NoDisposalRequirements.
•EnvironmentallyFriendly:98%oftheHyLiteLEDLampisRecyclable
Page:1of3
Incandescent HPS/HID CFL HyLite
800W 400W 300W 100W
88% 75% 67% Energy Savings (%)*
* Does not include Ballast Loss, Maintenance and Replacement Lamp Savings and Disposal Costs which can amount to additional Savings of 30~50%!
Replacewith
Lamp can be oriented in any position - does not affect or diminish the life of the Lamp
Universal Burning Positioning
HyLiteLEDHighPerformanceArc-CobLamps-Upto60,000hour*RatedPerformance Life. OutstandingQualityofLightwithEnergySavingsofupto 90% over Incandescent, 75%overHPS/MHLampsand67%overCFL.ARC-COB TM
LED
5” (127mm)
2.5”
(65m
m)
4.3”
(110
mm
)
11” (277mm)
400WMH / HPSEquivalent
*Depending upon the ambient temperature of the installation location
HighPerformanceLEDArc-CobLamp,100W FREE!20 kA
In-line Surge Protection Device Included.
Additional Protection for your HyLite Arc-Cob Lamp
at no Cost!
LED Product Partner
Reliable andLong-Lasting
Warranty
5years
Vibration andShock Resistant
Solid State
Radiation-FreeNo Humming
IRUV
No IR/UV
No Noise
113 LpWLM-79 Tested
High Efficacy
LM-80 TestedISTMT Tested
Reliability
Reduction ofup to 88%
Energy Costs
Up to 60,000 Hours
Low Voltage
Longer Life&
Beam Angle
Wide &Uniform
120°
For Enclosed Luminaires
Suitable
Zero Interference
No EMi / RFi
Suitable for
Damp Locations Enclosed Fixtures
Page:2of3
C0/180, 71.9°, 76.6°
C90/270, 21.7°, 47.9°
Unit: cd030
60
90
120
150-/+180
-150
-120
-90
-60
-30
0
700
1400
2100
2800
3500
High Performance LED Arc-Cob Lamp, 100W
Photometrics - Type III
Intensity: (Unit, cd)
Average Beam Angle (50%): 109.1°
Flux Out: 3160 lm
2 m6.5 ft.
Height
4 m13.1 ft.
6 m19.7 ft.
8 m26.3 ft.
10 m32.8 ft
Angle: 69.63° DiameterEAvg, Emax
278 cm9.1 ft.
556 cm18.3 ft.
835 cm27.4 ft.
1113 cm37 ft.
1391 cm45.6 ft.
512.9/743.7 lx47.65/69.1fc
128.2/185.9 lx11.91/17.27 fc
56.99/82.63 lx5.29/7.68 fc
32.06/46.48 lx2.98/4.32 fc
20.52/29.75 lx1.91/2.76 fc
ARC-COB TM
LED
C0/180, 55.7°, 56.2°
C90/270, 55.8°, 53.5°
Unit: cd0
30
60
90
120
150-/+180
-150
-120
-90
-60
-30
0
900
1800
2700
3600
4500
High Performance LED Arc-Cob Lamp, 100W
Photometrics - Type V
Intensity: (Unit, cd)
Average Beam Angle (50%): 110.6°
Flux Out: 8478 lm
2 m6.5 ft.
Height
4 m13.1 ft.
6 m19.7 ft.
8 m26.3 ft.
10 m32.8 ft
Angle: 109.29° DiameterEAvg, Emax
564 cm18.5 ft.
1128 cm37 ft.
1691 cm55.5 ft.
2255 cm74 ft.
2819 cm92.5 ft.
330.8/1033 lx30.73/95.93 fc
82.70/258.1 lx7.68/23.98 fc
36.76/114.7 lx3.41/10.66 fc
20.67/64.53 lx1.92/5.99 fc
13.23/41.30 lx1.23/3.84 fc
Model Delivered Suggested InputLine Base Dimensions&Weight(each) No. Watts Lumens Install Height Current Type Diameter Height Weight
HL-AC-100W-T3-E39 100 9,453<32ft.(10m) 361mA~1.0A E39/E40(Mogul) 4.3”(110mm) 11”(77mm) 2.2lb.(1kg)
HL-AC-100W-T5-E39 100 11,268
As part of the company’s continuous product improvement program, HyLite reserves the right to change materialsor modify the design of its product without notification. All Specifications subject to change without notice. All values are design and/or typical values when measured under laboratory conditions. Actual Values depend upon the ambient temperature of the installation location. Please consult factory for your specific requirements.
• MinimumLampCompartmentDimensionsforEnclosedFixtures:9.25”x9.25”x17.5”(235mmx235mmx440mm)
• ToPreventearlyLampFailure,LampshouldonlybeinstalledinOperatingEnvironmentsrangingfromaMinimumof-40°C(-40°F)toaMaximumof+55°C(131°F)
• Efficacy:113LpW • CRI:>80 • BeamAngle:110º~120º • Max.THD(%):<20% • UniversalInputVoltage
• PowerFactor:>0.9 • Protection:IP44 • RatedLife:50~60,000Hrs. • Warranty:5Years 100~277V,AC50/60Hz.
• 347V,480VAvailable with with External Step-Down Transformer only. Please see HL-DT-125VA-480-277VSpec.Sheetat:https://hyliteledlighting.com/resources/specification-sheets/
• CCT:5000°K~5500°Kforgreatervisibility.Productswith2400°K-6500°K(CCT)areavailableas“SpecialOrders” only and with Longer Lead Times
*Depending upon the ambient temperature of the installation location
Ideal for high-quality illumination in:
• WallPacks • FloodLights
• StreetLighting • ParkingLotLighting
• CanopyLights • WalkwayLighting
• SecurityLights • TunnelLighting
• PedestrianTunnels • Freezer&ColdStorageLights
• DrivewayLighting • ParkingGarageLights
Thermax tm -ProprietaryThermalManagementSystem:HyLite100WArc-Cobsusebothactiveandpassivecoolingmakingitan excellent retrofit. Active cooling uses no bearings, brushes, or other frictional parts to rub or wear out and has extremely low acoustical emissions. Longer LED life is assured by Thermax tm our Proprietary Thermal Management System that controls currentlevelstotheLEDsbasedontemperature.At149°F(65°C)theArc-CobbeginstocutbackonthecurrenttotheLEDstoeithermaintain,orreducethetemperaturebackdownto149°F(65°C),assuringcooleroperationandlongerlife.
Page:3of3
4” (100mm)
4.3” (110mm
)
5” (127mm)
2.5” (65mm
)4.3”
(110
mm
)
11” (277mm)
4” (1
00m
m) 2.85” (72m
m)
ARC-COB TM
LED
Warning - Risk of Fire or Electric Shock
• Disable all Power to the Lamp before Inspection, Installation, or Removal. Failure to do so will create a Hazardous and Fatal Working Environment.
• SuitableforuseinDry,DampandWetLocations.LampmustbeinstalledinaccordancewithNational,State,and/orLocalElectricalCodes. DoNotOpen–NoUserServiceablePartsInside.
• OperateinFixturesthatprovidetheFreeFlowofAiraroundtheLampHeatSink.InEnclosedFixtures,ensuretheLamphasenoughSpaceforHeatDissipation. This will ensure Lumen Maintenance and extend its Working Life. When products are used in Outdoor Fixtures, ensure the space is Waterproof and Well Ventilated.
• NotforuseonaDimmerorRemoteControls.ThisLamp must be controlled only by either a Switch or an Electronic Photosensor. Do not use a Mechanical Sensor.
• NotintendedforusewithEmergencyExitFixturesorEmergencyExitLights.
• Caution:WhenInstallingLampsinCorrosiveEnvironments,HyLitesuggeststhataHigh-Temperature,Moisture-Resistant,SiliconeGreaseorSealantbeusedto protecttheMetal-threadedbaseoftheLEDLamptopreventWaterand/orMoistureIncursionthatcanleadtoPrematureDegradationoftheLampBaseand eventual Lamp Failure. This is especially recommended for LED Lamp installations near Saltwater bodies.
• InstallingSurge/LightningProtectorsisHighlyRecommendedandhelpstoEliminatePrematureDriverFailurecausedbySurgesandPowerFluctuations.
©2012-2019HyLiteLED,LLC.,USA Formoreinformation,pleasevisit:https://hyliteledlighting.com/ 031219
Installation: HyLite LED Lampsaredesignedtoworkoff100Vto277V,AC.Ballast (if equipped) must be bypassed or removed from the fixture before installing the lamp. Eliminating theBallast savesadditional costs related to Maintenance, Energy Consumption and Performance.By-passingBallastwillalsoensurethatthereisnoEMi/RFinterference.ItisSTRONGLYRECOMMENDED that the Reflector in the Fixture be removed for Optimum Thermal Management and better Heat Dissipation. This will ensure Lumen Maintenance and extend its Working Life. The installer MUST also ensure and verify that NO Part of the installed LED Lamp should touch the Fixture Housing or Components.
Failure to follow these Instructions will result in a Damaged Product and will VOID Warranty. It could also result in an Electric Shock, or Fire.